DMR Modulo: Constant Volume Damper

The document describes DEC International's DMR Modulo constant volume damper. It regulates airflow to an adjustable setting through a rotating ring. It maintains constant airflow within a wide pressure range through a flexible silicone membrane. It fits easily into circular ductwork. Correct air balancing with these dampers is important for properly commissioned HVAC systems to avoid issues from over or under ventilation.

Uploaded by

zoltan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views3 pages

DMR Modulo: Constant Volume Damper

The document describes DEC International's DMR Modulo constant volume damper. It regulates airflow to an adjustable setting through a rotating ring. It maintains constant airflow within a wide pressure range through a flexible silicone membrane. It fits easily into circular ductwork. Correct air balancing with these dampers is important for properly commissioned HVAC systems to avoid issues from over or under ventilation.

Uploaded by

zoltan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

DEC INTERNATIONAL

TECHNICAL SPECIFICATIONS

DMR MODULO
CONSTANT VOLUME DAMPER
AIR MANAGEMENT SYSTEMS

PRODUCT PROPERTIES
Constant Airflow Regulator multi-airflow Dimensions - weight
Ø Duct ØN ØB A W (kg)
The DMR Modulo regulates to an adjustable airflow. One
80 76 85 65 0.07
code corresponds to several airflow setting options. The DMR 100 92 105 70 0.11
MODULO incorporates a rotating ring for a tool-free airflow 125 116 132 70 0.17
setting. 125 116 132 110 0.22
7 diameters (mm): 80, 100, 125, 150, 160, 200 and 250. 150 147 153 118 0.30
160 153 167 118 0.34
200 190 210 144 0.65
 Best constant airflow regulation thanks to the silicone 250 238 262 179 1.20
membrane (avoids clogging).
 Optimum silent operation (no mechanical clatter or other
noise interference due to variations in pressure).

Airflow accuracy
+/- 5 m3/h for nominal flow ≤ 50 m3/h.
+/- 10% for nominal flow > 50 m3h.
Operating differential pressure range:
Standard range: 50 - 250 Pa.
Temperature range of use:
-10 to 60°C.

The following information is indicated directly on the


product:
 Airflow direction
 Diameter in mm and inch
 Operating differential
pressure range
 Product code
 Traceability data
 Quality control
 The airflow setting range correlation table (in m3/h and cfm).

Principle The right balance in aeraulic networks


Operating Modern constructions need to be airtight in order to be energy
They fit easily into a part of the circular ductwork to maintain efficient.
constant and reliable airflow within a wide range of In addition to thermal comfort (heating or cooling) air-
differential pressure (50 - 250 Pa) for the standard version conditioning systems are now specifically sized to guarantee a
and for the high-pressure version (150 - 650 Pa). supply of fresh air into the building for health purposes (notably
in terms of oxygen content).
Its flexible membrane inflates and deflates according to the
difference in pressure between the upstream and Therefore it is increasingly important to ensure that operating
downstream flow, thus modifying the airflow. This principle airflows correspond to the ones calculated for the HVAC system
of operation guarantees constant airflow regardless of the sizing (air balancing).
pressure variations in the ductwork.
Correct air balancing is key to a properly commissioned HVAC
system and to avoid side effects generated by over-ventilation
(noise, high temperatures, high energy consumption) or by
under-ventilation (deteriorated air quality and uncomfotably cold
temperatures...)

LIABILITY: PLEASE NOTICE: TRADEMARKS:


The information contained in this brochure was current on the publication date. The consultant is responsible for the actual installation and mounting of DEC International and the DEC logo are
DEC INTERNATIONAL reserves the right to make changes in details at any time without the product. The mentioned values with respect to temperatures are not trademarks, or registered trademarks of
prior notice. In order to avoid misunderstandings, any interested party is advised to appropriate to be used to determine the physical properties. These Dutch Environment Corporation BV in
contact DEC INTERNATIONAL checking for any changes in materials and/or information properties are also dependent on humidity and the temperature of the air the Netherlands and/or other countries.
after this brochure was published. inside and outside of the H.V.A.C. system.
6/12/2013 DEC INTERNATIONAL - P.O. BOX 35 - NL-7500AA - ENSCHEDE - THE NETHERLANDS - WWW.DECINTERNATIONAL.COM
DEC INTERNATIONAL
TECHNICAL SPECIFICATIONS

DMR MODULO
CONSTANT VOLUME DAMPER
AIR MANAGEMENT SYSTEMS

Typical applications

Airflow stabilization for a ventilation or air-conditioning ductwork section

Exhaust airflow stabilization.


In air extraction, we recommend a 1-diameter distance between the terminal and the DMR to allow homogenization of air
velocities in the duct and thus avoid acoustic or aeraulic disturbances.

1 2 3
1/ DMR installed after a supply plenum box
2/ DMR installed after a BIM-type grille
3/ DMR installed before a fan coil

Supply airflow stabilisation.


In air supply, we also recommend a distance of 3 diameters between the terminal and the DMR to allow homogenization of the
air velocities in the duct and thus avoid acoustic or aeraulics disturbances.

1 2
1/ DMR installed before a supply plenum box
2/ DMR installed before a BIM-type grille

IMPLEMENTATION
DMR Modulo will push-fit into circular ducts in close proximity to a take-off or a terminal.
 Observe the installation direction (corresponding to airflow) directly indicated with an arrow on the MR.
 Can be mounted either horizontally or vertically. There is no recommendation regarding the positioning of the membrane.
 In order to avoid acoustic and aeraulic interference it is recommended to respect a minimal distance between the DMR and
the terminal (grille / diffuser / inlet):
- in extraction D = 3 Ø,
- in supply D = 1 Ø.

In extraction In supply

LIABILITY: PLEASE NOTICE: TRADEMARKS:


The information contained in this brochure was current on the publication date. The consultant is responsible for the actual installation and mounting of DEC International and the DEC logo are
DEC INTERNATIONAL reserves the right to make changes in details at any time without the product. The mentioned values with respect to temperatures are not trademarks, or registered trademarks of
prior notice. In order to avoid misunderstandings, any interested party is advised to appropriate to be used to determine the physical properties. These Dutch Environment Corporation BV in
contact DEC INTERNATIONAL checking for any changes in materials and/or information properties are also dependent on humidity and the temperature of the air the Netherlands and/or other countries.
after this brochure was published. inside and outside of the H.V.A.C. system.
6/12/2013 DEC INTERNATIONAL - P.O. BOX 35 - NL-7500AA - ENSCHEDE - THE NETHERLANDS - WWW.DECINTERNATIONAL.COM
DEC INTERNATIONAL
TECHNICAL SPECIFICATIONS

DMR MODULO
CONSTANT VOLUME DAMPER
AIR MANAGEMENT SYSTEMS

DMR Modulo installation


1. Adjust the airflow setting
Rotate the adjustment ring for a tool-free airflow setting until the
desired airflow is reached.

2. Position the MR Modulo


Introduce the DMR in the duct according to the arrow showing the airflow
direction. Minimum straight upstream and downstream distances must be
observed.

LIABILITY: PLEASE NOTICE: TRADEMARKS:


The information contained in this brochure was current on the publication date. The consultant is responsible for the actual installation and mounting of DEC International and the DEC logo are
DEC INTERNATIONAL reserves the right to make changes in details at any time without the product. The mentioned values with respect to temperatures are not trademarks, or registered trademarks of
prior notice. In order to avoid misunderstandings, any interested party is advised to appropriate to be used to determine the physical properties. These Dutch Environment Corporation BV in
contact DEC INTERNATIONAL checking for any changes in materials and/or information properties are also dependent on humidity and the temperature of the air the Netherlands and/or other countries.
after this brochure was published. inside and outside of the H.V.A.C. system.
6/12/2013 DEC INTERNATIONAL - P.O. BOX 35 - NL-7500AA - ENSCHEDE - THE NETHERLANDS - WWW.DECINTERNATIONAL.COM

You might also like