0% found this document useful (0 votes)
285 views4 pages

Data Sheet For Dynamic Braking Resistors: 1. Part Description

This document provides technical specifications for three types of dynamic braking resistors: RFD 200 (100W), RFP V 300 (300W), and RFP V 500 (500W). It describes warnings about high temperatures, required thermal overload protection, proper resistor selection and installation methods, including mounting positions and dimensions. Electrical ratings and certifications are provided for each resistor type.

Uploaded by

Dave Cárdenas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
285 views4 pages

Data Sheet For Dynamic Braking Resistors: 1. Part Description

This document provides technical specifications for three types of dynamic braking resistors: RFD 200 (100W), RFP V 300 (300W), and RFP V 500 (500W). It describes warnings about high temperatures, required thermal overload protection, proper resistor selection and installation methods, including mounting positions and dimensions. Electrical ratings and certifications are provided for each resistor type.

Uploaded by

Dave Cárdenas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

DATA SHEET FOR DYNAMIC BRAKING RESISTORS

1. Part description

This data sheet provides technical information for the following types of dynamic braking resistor supplied by Fairfild:

RFD 200 (100 W)


RFP V 300 (300 W)
RFP V 500 (500 W)

2. Warnings

Please observe the following warnings.

High temperatures – Risk of burn


Braking resistors can reach high temperatures.
Do not mount the resistor on a combustible surface.
Locate the braking resistor so that inadvertent contact is not possible.
Provide adequate ventilation
Use cable with insulation capable of withstanding high temperatures

Thermal overload protection must be used


The thermal switch must be incorporated into the overload protection circuit.
The thermal protection circuit must disconnect the AC supply to the drive if
the resistor becomes overloaded due to a fault.

3. Resistor selection

The resistance of the braking resistor must be higher than the minimum resistance specified in the drive User Guide.
The required Pulse Power rating must be calculated to suit the application. Refer to the Drive User Guide.

4. Installation

The resistor must be mounted as shown in the data table below.


The resistor housing must be grounded.
The cable between the resistor and the drive must be shielded if the cable is not fully enclosed inside a metal enclosure. The cable does not need
to be screened if the braking resistor and drive are both fully enclosed inside the same metal enclosure.

5. Installation bracket for RFD 200

An optional installation bracket is available for use with the RFD 200 resistor, part number 6541-0305-00. The dimensions are shown below.
DATA SHEET FOR DYNAMIC BRAKING RESISTORS

6. RFD 200 data

RFD 200 (100 W)

CT Part number 1220-2201 1220-2401 1220-2501 1220-2681 1220-2801 1220-3101 1220-3131 1220-3271

Pulse Power (W) Ta ~ 40 ED 6 % 900


°C. Referred to a cycle ED 15 % 500
duration of 120 s.
Approximate value ED 25 % 300
(depending on resistance) ED 40 % 200
Resistance values at 20 °C 20 Ω 40 Ω 50 Ω 68 Ω 80 Ω 100 Ω 135 Ω 270 Ω
Degree of protection (EN 60529) IP54
Nominal continuous power (W) Ta ~ 40 °C 100 W
Tolerance of resistance at 20 °C ± 10 %
Cooling Natural convection
Housing temperature at nominal continuous
~ 250 °C
power Ta ~ 40 °C
Minimum distance to other equipment > 20 mm
Electrical connection 2 x AWG 14 /L = 50 cm
Operating temperature range -25 to +40 °C
Maximum permissible operating voltage UL 1000 V / CE 1000 VDC
Thermal switch operating temperature 150 °C
Testing voltage 4 kV AC (1 s)
Approvals / marking UL file E228809

Mounting positions

Dimensions
DATA SHEET FOR DYNAMIC BRAKING RESISTORS

7. RFP V 300 data

RFP V 300 (300 W)

CT part number 1220-2206 1220-2508 1220-2686 1220-2802 1220-3108 1220-3136 1220-3276

ED 6 % UL 2250 W / CE 2700 W
Pulse Power (W) Ta ~ 40 °C.
Referred to a cycle duration ED 15 % UL 1250 W / CE 1500 W
of 120 s. Approximate value ED 25 % UL 750 W / CE 900 W
(depending on resistance)
ED 40 % UL 500 W / CE 600 W
Resistance values at 20 °C 20 Ω 50 Ω 68 Ω 80 Ω 100 Ω 135 Ω 270 Ω
Degree of protection (EN 60529) IP54
Nominal continuous power (W) Ta ~ 40 °C UL240 W / CE 300 W
Tolerance of resistance at 20 °C ± 10 %
Cooling Natural convection
Housing temperature at nominal continuous power Ta ~
UL ~300 °C / CE ~ 360 °C
40 °C
Minimum distance to other equipment > 20 mm
Electrical connection PTFE single core AWG14 360°C 1000 V style 10724 long 300 mm ± 5 mm
Operating temperature range -25 to +40 °C
Maximum permissible operating voltage UL 1000 V / CE 1000 VDC
Thermal switch operating temperature 150 °C
Thermal switch rated voltage AC/ DC AC: 250 V (VDE) 277 V (UL) / DC: 12 V
Testing voltage 4 kV AC (1 s)
Approvals / marking UL File: E228809

Mounting positions

Dimensions
DATA SHEET FOR DYNAMIC BRAKING RESISTORS

8. RFP V 500 data

RFP V 500 (500 W)

CT Part number 1220-2208 1220-2509 1220-2688 1220-2803 1220-3107 1220-3278

Pulse Power (W) Ta ~ ED 6 % UL 3600 W / CE 4500 W


40 °C. Referred to a
cycle duration of 120 s. ED 15 % UL 2000 W / CE 2500 W
Approximate value ED 25 % UL 1200 W / CE 1500 W
(depending on
resistance) ED 40 % UL 800 W / CE 1000 W

Resistance values at 20 °C 20 Ω 50 Ω 68 Ω 80 Ω 100 Ω 270 Ω


Degree of protection (EN 60529) IP54
Nominal continuous power (W) Ta ~ 40 °C UL 370 W / CE 500 W
Tolerance of resistance at 20 °C ± 10 %
Cooling Natural convection
Housing temperature at nominal continuous power Ta ~
UL ~300 °C / CE ~ 360 °C
40 °C
Minimum distance to other equipment > 20 mm
Electrical connection PTFE single core AWG14 360°C 1000 V style 10724 long 300 mm ± 5 mm
Operating temperature range -25 to +40 °C
Maximum permissible operating voltage UL 1000 V / CE 1000 VDC
Thermal switch operating temperature 150 °C
Thermal switch rated voltage AC/ DC AC: 250 V (VDE) 277 V (UL) / DC: 12 V
Testing voltage 4 kV AC (1 s)
Approvals / marking UL File: E228809

Mounting positions