AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP Issue: 1 CLASSIFICATION: Commercial in Confidence

The document provides technical specifications and installation instructions for the AMI-GFV KW 903-SP synchro retransmission unit. It can accept gyro compass outputs such as stepper, NMEA 0183, or 1:1 synchro and convert them to produce a 360:1 synchro output. The document describes pre-installation checks of the existing system, connections for different gyro inputs, settings for the main transformer output voltage, and testing procedures once installed.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
124 views

AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP Issue: 1 CLASSIFICATION: Commercial in Confidence

The document provides technical specifications and installation instructions for the AMI-GFV KW 903-SP synchro retransmission unit. It can accept gyro compass outputs such as stepper, NMEA 0183, or 1:1 synchro and convert them to produce a 360:1 synchro output. The document describes pre-installation checks of the existing system, connections for different gyro inputs, settings for the main transformer output voltage, and testing procedures once installed.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 18

AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP

Issue: 1
CLASSIFICATION: Commercial In Confidence

This Page Left Blank Intentionally

Page 1 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence

Document Date Modification Number (where applicable)


Issue Brief Record of Change and Reason for Change
1 15.08.02 Original Issue

NOTE: All alterations must be verified by re-authorisation and approval of the


complete document.

Page 2 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence

SYNCHRO RETRANSMISSION UNIT

KW903-SP / SHP

TECHNICAL MANUAL

CONTENTS

INTRODUCTION ....................................................................................................... 4
SPECIFICATION ....................................................................................................... 4
MAIN TRANSFORMER ............................................................................................. 5
ANSCHUTZ ADAPTER ............................................................................................. 6
PRE - INSTALLATION CHECKS............................................................................... 7
INSTALLATION NOTES............................................................................................ 7
TESTING THE REPEATERS .................................................................................... 9
TESTING THE GYRO ............................................................................................. 10
OPERATIONAL CHECKS ....................................................................................... 11
CHANGING BETWEEN No 1 to No 2 input............................................................. 12
PRINCIPLES OF OPERATION ............................................................................... 13
MEASURING PHASE SHIFT ON OUTPUT ............................................................ 15
FINAL TEST PROCEDURE .................................................................................... 16
CIRCUIT BOARD .................................................................................................... 18

AMI-GFV MARINE LTD

18 Canute Road
Ocean Village
SOUTHAMPTON
SO14 3FJ
United Kingdom

Tel No 44(0) 23 8048 0450


Fax No 44(0) 23 8048 0451

E-mail [email protected]
Web www.amimarine.com

Page 3 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence

SYNCHRO RETRANSMISSION UNIT KW903-SP

INTRODUCTION

The RTU converts several types of gyro compass output to 360:1 synchro signals the
main application being in refits on ships that already have synchro repeaters.

Input signals may be stepper including Sperry a/c stepper NMEA 0183 or 1:1
synchro. A second NMEA input provides for back up from a magnetic system or
second gyro.

The unit is all solid-state built for highest reliability and simplicity of installation. The
KW903 features test modes to prove a system installation. The synchro output is
generated “digitally” without high power amplifiers. The software makes the synchro
output move in small steps 24 per degree and thus a smooth rotation is given even
for a coarse input of 6 steps per degree.

SPECIFICATION

INPUT: - Standard Version:


Standard DC stepper 4 to 35 v DC pure DC or
Rectified unsmoothed DC or “90 x 400Hz contactless
transmitter. Tracking rate > 200 degrees/sec.
OR NMEA 0183 $HEHDT xxx.xT cr If:

INPUT: - 1:1 Synchro Version:


115/90 or 26/11.8 synchro 50/400 Hz
Resolution 12 bits .09 degree.
OR NMEA 0183 $HEHDT xxx.x T cr If.

SECOND INPUT:
NMEA 0183 all valid heading sentences.
First or second input selectable by switch.

SYNCHRO OUTPUT:
Voltage set by transformer used.
Standard voltages are REF/Signals 115/90 50/68 60/24
Ref. current 2A. Phase current max 0.2A per phase.
(Subject to test and tuning of reactance).
1 revolution per degree follow up rate adjustable 2 to 11
deg/sec.
24 states per revolution with software control.

NMEA 0183 OUTPUT:


Diagnostic data.

Page 4 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence

MAIN TRANSFORMER

The transformer is multi tapped as best shown in the schematic showing various
connections. The standard transformer gives a 115v ref. 90v signals output but this
is normally REDUCED by selecting the 132v mains input tapping. This runs the
synchro repeaters at a reduced voltage and we have found that under-rating is
beneficial. The exact voltage applied is not critical and you will be checking that the
repeaters follow later.

The output can be fine-tuned with the addition of another transformer. Anschutz
repeaters use 50v/20v or 60v/24v. We have an adapter for those voltages. See
below.

The KW903’s reference output is intended to drive synchros, not high power course
recorders etc. If the ship’s equipment draws high power from the reference supply fit
an external reference transformer and disconnect the KW903’s reference supply.
You may find such an external transformer already exists in the old system such as
Kurs and may be reused.

If the standard transformers do not produce exactly what is required we can make
transformers to suit your exact need.

DO NOT CONNECT SYNCHROS UNTIL YOU HAVE CHECKED THE KW903


OUTPUT!

Page 5 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence

ANSCHUTZ ADAPTER

Page 6 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence

PRE - INSTALLATION CHECKS

When a gyro is being replaced because it is old and worn out our experience shows
that there will also be repeaters old and worn out. This includes electrical and
mechanical faults. The gears of the repeaters should be checked for wear
particularly the small gear on the synchro motor. It is essential faulty repeaters are
disconnected or repaired. Just one faulty synchro repeater can stop the whole
system working.

Use the existing gyro before it is switched off turn it and check that all repeaters
follow. We provide a checklist to record your tests.

Disconnect the synchro transmitter and measure the resistance of all the repeaters in
the system connected in parallel.

R1 - R2 = ohms

S1 - S2 = S2 - S3 = S3 - S1= These values should be equal

R1 - S1 = Should be open circuit

R1 - Ground = Should be open circuit

S1 - Ground = Should be open circuit

INSTALLATION NOTES

POWER

Measure power supply input. If the voltage varies from 110/220 the synchro output
will vary in the same ratio. The KW903 transformer has taps, which may be used to
adjust the output voltage.

Page 7 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence

GYRO INPUT

If the gyro has an NMEA 0183 output connect it to NMEA channel 2. This will be
selected as “No. 1”. NMEA data to 0.1 deg provides a smoother output than
stepper.

Connect stepper input to SK5. For DC input set jumpers J1, J2, J3 to full wave
rectification. This handles either polarity and rectified unsmoothed DC. For 90x 400
Hz contactless transmission set the three jumpers for half wave rectification.

Set J4 and J5 to suit the gyro input. These jumpers indicate the gyro type at switch-
on and have no effect if changed after switch-on.

For NMEA heading input instead of stepper the jumpers do not matter.

90x contactless transmitter as in SR220


It’s Reference R1, R2 is supplied with 115v 400Hz.

Do not connect its R1, R2 to KW903!


Connect transmitter “N” to KW903 stepper common
Connect S1, S2, S3 to S1, S2, S3
Jumpers J1, J2, J3 to half wave rectified.

If KW903 output turns wrong way final test reverse S1, S2.

Note stepper input LEDs may not go out entirely. This is ok for 90x NOT ok for DC
stepper!

SECOND GYRO OR MAGNETIC BACK UP

Connect the NMEA input to NMEA Channel 1. It will be selected as “No2”. This
channel is programmed to use all valid heading inputs, including Cetrek proprietary
data. (Channel 2 only accepts gyro $HEHDT).

Page 8 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence

TESTING THE REPEATERS

DISCONNECT SYNCHRO OUTPUT

SET SWITCH TO “B” SWITCH ON!

TEST FACILITY

The KW903 - SP starts in a test mode. Changing the switch exercises the output
even without a gyro connected. This facility is used to test the synchro repeaters.
Try the positions and you will see the synchro output LEDs rotate.

Anticlockwise rotation at 1 degree/second.

B = Stop. (Belay)

C = Clockwise rotation at 1 deg/sec.

D = Demo mode very slow at 0.1 deg/sec.

E = Demo mode at 1 deg/sec.

F = Fast demo mode 4 deg/sec.

TESTING THE SYNCHRO REPEATERS

In the synchro distribution unit disconnect all repeaters. Connect to the KW903.
Switch to B and switch on the KW903. The advice which follows will let you test the
synchro repeaters as best you can, and find possible faulty ones.

There are 1 ohm resistors in the reference and phase outputs. Connect a meter set
to a low voltage range across these resistors to measure reference and phase
current. The KW903 can supply 2A reference and 2A current in any one phase. (1v
measured = 1 amp of course). Ideally please connect an oscilloscope.

Connect up the synchro repeaters one by one and make sure they do not take
excessive current.

To test that the repeater turns and follows correctly switch from B to A or C. Since it
will be rotating at 1 deg/sec and the NMEA out led is flashing at 1 per second you
can have a good idea how far you have turned. It is helpful to have two people with
portable radios during these tests. If any repeater draws unusual current or does not
turn smoothly or loses step it is faulty. Isolate it and do not connect until it is fixed.

Finally set to B and align all the repeaters to the same heading. Switch to D and
leave the KW903 exercising all the repeaters. At any time you can stop it by

Page 9 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence

switching back to B. All repeaters should still be aligned. Next try the faster test
modes E and F. if any drop out of alignment remove them they are faulty.

FINAL MEASUREMENT

When all is satisfactory stop the rotation by selecting B but stop it if possible at a
position where the phase you are measuring is taking maximum current. Switching
from B to A and back quickly will nudge it into place. Complete the checklist with this
value. If you have an oscilloscope also measure the phase shift: (see note.)

TESTING THE GYRO

Switch off. Set the hex switch to 0 and switch on. Toggle the alarm switch and leave
it on. If the alarm sounds the KW903 is indicating a GYRO FAULT!.

The stepper input LEDs will be seen to rotate if the gyro turns. NMEA input LEDs will
flash in time with the data input. Align the repeaters to the gyro. Turn and hold the
gyro and check the repeaters move to that position. Swap a pair of wires if it turns
the wrong way.

If the alarm sounds on rapid turns of the gyro it is usually caused by the stepper RTU
being too lightly loaded, so that its internal capacitance cause slow transitions and
false steps. Fit load resistors across the stepper output e.g. 100 ohms.

OUTPUT FOLLOW-UP RATE

The hex switch allows selection of output rotation rate according to the formula
Degrees per second = 2 + Switch setting. Thus 0 = 2 deg/sec 3 = 5 deg/sec. Faster
follow up rates are available up to 9 but are not recommended. Chose a setting one
step faster than the ship can possible turn.

This feature is provided because repeaters may not follow really fast turns, which a
gyro may give in “slew” mode. Do not confuse this follow-up with input tracking rate.
The KW903 tracks DC stepper at more than 1000 degrees per second but it limits the
output rotation for the sake of the synchro repeaters.

Page 10 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence

EXTERNAL ALARM

For safety reasons an independent external alarm should be connected. The


KW903 provides a pair of contact that are held open when all is well. There are a
large range of alarms easily available. We recommend an audible alarm with speech
output e.g. RS 216-3894.

Such an alarm can not detect faults on the synchro transmission system, which could
be caused by a KW903, output failure. or a faulty synchro repeater, shorts, etc. This
is so with all transmission systems. To detect such faults a synchro monitor and off-
course alarm should be fitted. The AMI KW902 is recommended.

OPERATIONAL CHECKS

STATUS LED
Green = all ok

Flashing = a problem detected e.g. gyro false steps, gyro


or power interruption, loss of reference in output.
Toggle alarm switch to clear alarm condition.
If alarm returns there Is a problem

Red = Alarm is switched off, or KW903 hardware failure.


The software does not generate red state.

Off = No 5 volt power!

STEPPER INPUT
The LEDs indicate state of gyro input and rotate in
sequence i.e. 001 011 010 110 100 101. LEDs all on or all
off indicates a gyro problem.

NMEA 0183 INPUTS


These LEDs flash in time with the data input.

NMEA 0183 OUTPUT


Flashes at least once per second with each data output it
flashes at a faster rate when the ship turns.

SYNCHRO OUTPUT LEDS


These indicate roughly the state of the synchro output.
The brightness changes but they only go out at exact half
degree positions.

Page 11 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence

CHANGING BETWEEN No 1 to No 2 input

Put a man on the wheel and check your course with magnetic compass. Change
over the selector switch. The KW903-S will maintain the last synchro output state
until a new changed heading comes in. When you see the output is happily following
the input with no alarm condition the job is done.

If your two inputs were different for instance gyro saying 010 and second input from a
magnetic compass saying 020 you may have expected to change the mechanical
repeaters 10 degrees on switch over. This does not happen there is a smooth
transition from one to the other.

Check your heading and alignment of repeaters and always navigate with caution.

Magnetic pick-off and fluxgate compasses

When used to back-up a gyro, results are often disappointing. It is a very skilled task
to make a pick-off coil system work well. Electronic fluxgate compasses need to be
adjusted or compensated like a magnetic compass and experience has shown it very
difficult to make them work on steel ships.

The KW903 needs an NMEA input from such sensors. Fit an NMEA heading
indicator to indicate the magnetic heading then you will see just how it is performing.
The KW903 will perform as well as it’s input.

Some electronic sensors output heading in 1 degree steps so the KW903 will be
seen to rotate to whole degree positions.

A properly installed and corrected magnetic system will work well.

Page 12 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence

PRINCIPLES OF OPERATION

The heart of the unit is the microprocessor software in EPROM, which controls the
whole input and output processing. The unit divides into convenient sections.

1 Power supply

2 Gyro input interfaces

3 Synchro power driver

4 Microprocessor

Power supply

The mains input is fused switched and filtered. The filter capacitors are centre
tapped to earth and must be earthed for safety. The filtering is for EMC reasons.

The multi-tapped transformer is specified to provide secondary voltages for reference


and synchro phases. One “9v” winding is used for the 5v logic power supply.

Gyro input interfaces

Stepper gyro signals including a.c. Sperry signals are fed to opto isolators. Their
output goes to ports on the microprocessor. It is entirely up to the software to
process these signals to keep track of turns. Stepper signals give 6 steps per
degree.

The software will cause the “alarm” condition if a false step state is ever found that
being a gyro fault. The most common reason is the gyro’s step signals moving slowly
due to capacitance when the stepper output is lightly loaded. Fit some load resistors
to cure it.

The 1:1 synchro interface uses a synchro to digital converter with data transfer via
opto isolators to the microprocessor. Thus the common line of the SDC interface
floats above ground for we do not want to put any ground on the synchro transmitter.

The software is responsible for reading and turning the SDC data into heading. The
SDC chip has a fault indication bit which is active if there is a problem with the
synchro input. Again this causes the alarm state. The 12 bit accuracy gives heading
to better than 0.1 degree. The chip is a high precision device. The synchro input
must be phased and adjusted to achieve precise NMEA output.

NMEA 0183 inputs are also opto isolated before being passed to the microprocessor
which has 2 UARTS to receive the data. The software is written to accept all valid
NMEA sentences from the No 2 Ch 1 input and the standard gyro sentence $HEHDT
on the No 1 Ch 2 input.
It is again the software, which controls the use of No1 or No2 inputs.

Page 13 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence

Synchro Power Driver

A synchro transmission has three values at 120 degree offsets whose value is V*
sine of angle. Thus the voltage say S1-S2 varies from 0 to 90v at 90 degrees 0 at
180 degrees and reverse phased 90v at 270 degrees. The standard synchro
retransmission system is 1 revolution = 1 degree.

Since input signals are only accurate to 0.1 degrees the synchro output can only
reflect this that is 10 steps per degree 36 degree turn of the motor. Stepper input
means rotation positions at 60 degree intervals. This design provides 24 positions of
the output at 15 degree intervals. The software moves the synchro through these 24
positions to smooth the jumps in heading output.

The principle behind the design is that we will generate just two outputs S1-S2 and
S2-S3. The value of S3-S1 comes automatically and I invite you to work it out for
yourself.

To achieve 24 states of synchro output we use a transformer with taps on the


secondary approximately equal to the synchro voltages at 15 degree intervals. The
voltages are 0, 23, 45, 72, and 89 for a 90v system. They are less for other systems
but in the same ratio. Page 1 of the schematic shows how the transformer taps are
connected to IC8 to 19 which are opto-coupled SCRs or AC solid state relays. The
software selects the appropriate one to be switched on which then selects the
appropriate transformer tap. IC 22 to 29 are controlled by software to select the
relative phase of the voltage. The result is the generation of an S1-S2 voltage and
an S2-S3 voltage.

Each transformer tap has a 10 ohm limiting resistor and each section a fuse. The
synchro output has 1 ohm resistor to aid measuring current and RFI filters.

Again note that is up to the software to control the switching of IC8 to 29. I leave it to
you to work out what happens if IC14 and IC19 were selected together. These IC’s
have “zero turn off” and turn on at about 5v on the AC side. The software is written
only to change the control state at about maximum excursion of the reference voltage
never near zero crossing point. IC39 provides the reference to logic interface. The
zero crossing feature minimises any RFI problems.

The way that zero crossing switching affects the receiving synchro minimises stress
and jerk on it for a new state rises from the zero crossing when it is not energised so
it starts to move to a new position with weak voltage which increases.

Page 14 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence

Microprocessor

The Dallas 80C320 features two uarts for serial data input with instruction execution
at about 2.5 times the original Intel design. One advantage is that clock speed may
be kept low which minimises RFI/EMC problems. IC30 31 32 and 36 must all be
good for microprocessor to run the software in the eprom.

IC36 is a voltage and program run monitor known as a watchdog. If the 5v dips due
to power failure it stops the microprocessor and restarts it after power is restored.
IC36 a MAX1232 must also receive frequent stimulation from the microprocessor.
The software tickles the watchdog routinely but if this tickling stops (Failure
accidental short circuit)? for half a second the watchdog will bark and reset the
microprocessor.

The microprocessor shifts data into a serial to parallel shift register IC34 37 this being
the required state of synchro output. Note that should the watchdog go to a reset
condition as at switch on and switch off the shift register is instantly cleared
preventing erroneous operation of the synchro drivers.

The alarm circuit includes buzzer bi-colour led and relay controlled by the
microprocessor program via IC42. The external alarm relay goes to alarm state
when alarm is switched off. This is intentional. A remote alarm should have its own
disable facility.

EMC

I have made mention of the design features which minimise EMC. The ground plane
of the pcb is another feature. All the tests we have made as with all other AMI
products make it easy for us to certify the product as compliant with the EMC
directive.

MEASURING PHASE SHIFT ON OUTPUT

If at all possible we would like to check the phase shift due to reactive loading of the
synchro output. If it is significant we will have to fit capacitors to tune it out. It is
important that this test is done on all new installations until we have built a data base
of what is found in practice. It requires a dual beam oscilloscope of no great
bandwidth. The usual engineer’s portable ‘scope will be fine.

Do this test from the start of putting the repeaters on line and certainly at the end with
all repeaters connected.

Use the wires on the 1 ohm resistors R71 72 to make the connection.

Connect one channel probe to S1 its earth clip on S2 bottom end of R72 (it is alright
to earth S2 if it is a battery ‘scope all the better). This measures S1 - S2 voltage.

Page 15 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence

Connect the second channel to the top end of R72. This measures the voltage
across the resistor to indicate S2 current.

Get a stable picture of two sine waves and draw it on paper. Please try to measure
any phase shift between the two waveforms and fax us with your picture.

FINAL TEST PROCEDURE

This is a simple test procedure to prove the functioning of the KW903. It is not a
method of demonstrating all functions. A test engineer is free to make any further
tests he chooses.

CONNECTIONS

Connect to AC mains

Connect to Stepper input to Step Generator

Connect an NMEA heading source to NMEA input appropriate

Connect a PC to NMEA out

Connect a repeater to the synchro output

SWITCH SETTING: Switch to 0

Switch on. Confirm the audible alarm sounds.

Move the step input or 1:1 input very slowly. Confirm the repeater moves
smoothly through 24 positions in one degree.

SELECT NMEA INPUT: Confirm the repeater follows an NMEA input.

SWITCH to “F”

Leave the KW903 exercising for at least one hour but as long as convenient. Check
that nothing gets hotter than normal. From time to time switch back to “D” and
confirm the repeater follows smoothly.

Page 16 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence
TRANSFORMER SETUP

Page 17 of 18
CLASSIFICATION: Commercial In Confidence
AMI-GFV Manual KW 903-SP Doc No: AMI-GFV TM903-SP
Issue: 1
CLASSIFICATION: Commercial In Confidence

CIRCUIT BOARD

Page 18 of 18
CLASSIFICATION: Commercial In Confidence