0% found this document useful (0 votes)
111 views2 pages

Systeme PV Didactique ED-9720

This document describes a new and renewable energy trainer that allows users to conduct experiments on energy production from solar cells. It includes modules for energy production from a solar cell panel, energy processing through an AC/DC inverter and charge controller, and energy storage in batteries. The trainer also includes components for measuring voltage, current, and power, as well as software for simulating photoelectric effects and basic circuit configurations.

Uploaded by

BOUJBARI HAFID
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
111 views2 pages

Systeme PV Didactique ED-9720

This document describes a new and renewable energy trainer that allows users to conduct experiments on energy production from solar cells. It includes modules for energy production from a solar cell panel, energy processing through an AC/DC inverter and charge controller, and energy storage in batteries. The trainer also includes components for measuring voltage, current, and power, as well as software for simulating photoelectric effects and basic circuit configurations.

Uploaded by

BOUJBARI HAFID
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

1/2

• New & Renewable Energy


_____

New
NEW & RENEWABLE
ENERGY TRAINER
• Conversion experiments on the produced energy(power production/processing)
ED-9720
• Characteristics of Solar Cell module’s voltage and current
• Alarm beep for wrong wire placement
• Voltmeter and ammeter as included for measuring AC and DC
• Control by PC and waveform and graph output
RENEWABLE
ENERGY
NEW &
PART2

> EXPERIMENTS
SOFTWARE
• Understanding of the solar cell energy
• Photo electricity simulation • LabVIEW Software
• Ohm’s Law and voltmeter/ammeter Data Monitoring DC Module
• Characteristics of solar cell(Isc, Voc) AC(Inverter) Module

• Light source’s intensity and shadow


• Charge using the solar cell
• AC/DC Inverter
• Standalone-type 12V solar cell system

> CONFIGURATION
• Basic Module
» Energy Production Module(in upper body)
› Solar Cell Panel
› Rheostat, Reflection Panel • Simulation Software
» Energy Processing Module(in lower body) » Photo electricity simulation followed by the voltage
› AC/DC Inverter impressed onto a metal plate
› Charge Controller » Photo electricity simulation followed by the types of a
› Battery metal plate
› AC/DC Tester » Photo electricity simulation followed by the light’s
» Communication Module wavelength
› Multi RS-485 Converter » Basic circuit configuration
› RS-485 Communication Board » Understanding of the current flow
• Integrated System(Option) » Simulation for the measured voltmeter/ammeter
» 300W Wind Generator Trainer(ED-9732) » Simulation by controlling voltage/current values
» Simulation followed by the changes in voltage, current
and resistance values

82 _ ED Co.,Ltd.
2/2

_____

NEW & RENEWABLE


ENERGY TRAINER ED-9720
> SPECIFICATIONS

• Solar Cel(Energy Production Part) • AC Load

RENEWABLE
ENERGY
» Serial/parallel wiring » Fluorescent Lamp

NEW &
PART2
» Max. Operating Power : 5W › Operating Voltage : 220VAC
» Open Voltage : 20.5V › Rated Input Current : 0.09A
» Short Current : 0.3A › Lighting Frequency : 42KHz
» Operating Voltage : 17.64V » 220V Power Outlet
» Operating Current : 0.284A › Allowable Voltage : 220V/15A
» Dimmer Switch : 1KW • DC Load
» Halogen Lamp : 150W » DC Motor
• Charge Controller › Operating Voltage : 12V,
» System Voltage : 12V › Power Consumption : 0.63W
» Max. Charge Current : 10A/15A/20A › Speed : 6,100rpm
» Max. Load Current : 10A/15A/20A » DC Lamp
» Self Power Consumption : 6~9mA › Operating Voltage : 3~12VDC
» Charge Voltage(Float) : 13.8V • DC Voltage Meter, DC Ampere Meter
» Discharge Blocking Voltage : 11.4V » Voltage : 100~240VAC 50/60Hz
» Load Reconnecting Voltage : 12.4V » Power Consumption : 5VA
» Temperature Compensation : 20mV » Max. Indication Range : -1999~9999(4행)
• AC/DC Inverter » RS-485 Communication Output :
» Rated Continuous Output : 350W 1200/2400/4800/9600bps
» Max. Instant Output : 700W • Multi RS-485 Converter(ED-9710-73)
» Input Voltage : 10~15VDC » Processor : Atmega128, 8bit RISC
» Output Voltage : 220VAC » Memory : 128k Program Flash, 64k SRAM
» Low Voltage Alarm : 10.5V ±0.5V » Program Downloader : ISP
• Energy Storage Module » Interface : RS-485, RS-232, USB
» MF Battery » 485 Driver Chip : ADM1485
› Voltage : 12V » Power : 5V
› Capacity : 2.0AH • RS-485 Connector(ED-9710-71)
» Battery Charger » Communication Speed : 9600bps
› Rated Input Voltage : 220V/60Hz » Interface : RS-485
› Rated Input Current : 170mA » No. of Pin : 32pin x 2,
› Rated Output Voltage : 12VDC » High brightness Chip LED
› Rated Output Current : 1.6A » Operating Voltage : 3V
• Buzzer for Input Polarity » Color : Yellow, Red
» Operating Voltage : 5~12V
» Function : Alarm for wrong wire placement GENRAL CHARACTERISTICS
• AC Voltage Meter(2ea), AC Ampere Meter(2ea)
• Input Voltage : AC 220V 60Hz
» Voltage : 100~240VAC 50/60Hz
• System Dimension : 620(W) x 380(H) x 200(D)mm
» Power Consumption : 5VA
» Max. Indication Range : -1999~9999(4 lines)
» RA-485 Communication Output : ACCESSORIES
1200/2400/4800/9600bps • Cable(Power, Serial, Circuit Connection) : 1set
» Protocol : Modbus • User Manual : 1ea

www.ed.co.kr _ 83

You might also like