0% found this document useful (0 votes)
209 views

Analysis and Design of Beams

This document provides an example of analyzing the adequacy of a rectangular reinforced concrete beam. It includes the following key steps: 1. Calculate the reinforcement ratio (ρ) and check if it satisfies code requirements for minimum reinforcement and maximum reinforcement. 2. Calculate the depth of the neutral axis (c) using the balanced strain equation. 3. Determine the strength reduction factor (φ) based on the calculated strain in the extreme tension fiber. 4. Calculate the design bending moment capacity (φMn) of the beam based on the area of steel and location of the neutral axis. 5. Calculate the factored bending moment (Mu) applied to the beam based on the given load information
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
209 views

Analysis and Design of Beams

This document provides an example of analyzing the adequacy of a rectangular reinforced concrete beam. It includes the following key steps: 1. Calculate the reinforcement ratio (ρ) and check if it satisfies code requirements for minimum reinforcement and maximum reinforcement. 2. Calculate the depth of the neutral axis (c) using the balanced strain equation. 3. Determine the strength reduction factor (φ) based on the calculated strain in the extreme tension fiber. 4. Calculate the design bending moment capacity (φMn) of the beam based on the area of steel and location of the neutral axis. 5. Calculate the factored bending moment (Mu) applied to the beam based on the given load information
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

Chapter 2

Analysis and Design of Beams


2.1 Analysis of Rectangular Beams with Tension Reinforcement
• Generally , in the analysis problems the following information are known:
1. Beam dimensions and reinforcement (b,h,d and As).
2. Materials strength (fy and fc`).

As (Reinforcement area)

And following information are required:


• Check the adequacy of the section according to ACI requirement.
• Compute design moment ∅Mn.
• Compute the maximum live or dead load.

Lec. Hasanain M. Al-Musawi Reinforced Concrete Design I Page 1


Chapter Two: Analysis of Singly Reinforced Rectangular Beam 3rd Stage

Procedure Analysis for Rectangular Beams with tension


Reinforcement (Singly reinforcement)
As
1. Calculate ρ =
bd
π
Where As = n × × D2
4
n = number of bars.
D = diameter of reinforcement bar.
Check if the provided ρ is in agreement with ACI requirements.
f` εu
ρ ≤ ρmax = 0.85β1 c
fy εu + 0.004
εu = 0.003
0.25√fc` 1.4
As ≥ As minimum = bw d ≥ bw d
fy fy
2. Calculate ∅
As × fy
a=
0.85 × f`c × b
a
c=
β1
• According to ACI code β1 can be calculated from table below

dt−c
𝜀t = 𝜀u where: 𝜀 u = 0.003
c
• If 𝜀 t ≥ 0.005, then ∅ = 0.9
• If 𝜀 t < 0.005 then
∅ = 0.483 + 83.3 × 𝜀t

Lec. Hasanain M. Al-Musawi Reinforced Concrete Design I Page 2


Chapter Two: Analysis of Singly Reinforced Rectangular Beam 3rd Stage

3. Calculate ∅Mn
∅Mn can be calculated from:
a
∅Mn = ∅Asfy(d − )
2
Or
a
∅Mn = ∅0.85fc`ab(d − )
2
Or
ρfy
∅Mn = ∅ ρfybd2(1 − 0.59 )
f`c
4. Find Mu and compare it with ∅Mn
If ∅Mn ≥ Mu the section is Ok.
Else if ∅Mn < Mu the section is not Ok.

Lec. Hasanain M. Al-Musawi Reinforced Concrete Design I Page 3


Chapter Two: Analysis of Singly Reinforced Rectangular Beam 3rd Stage

Example 1: Check the adequacy of the beam shown below according to ACI
requirement, use fc`= 25 MPa, fy = 400 MPa, neglect the self-weight
Pu=100 kN

3∅20mm
Solution:
π 𝜋
As = n × × D2 = 3× × 202 = 942 mm2
4 4
As 942
ρ= = = 5.71 × 10-3
bd 300 × 550
fc` 𝜀𝑢 25 0.003
ρmax = 0.85β1 = 0.85 × 0.85 × × = 19. 4 × 10-3
fy 𝜀𝑢 + 0.004 400 0.003 + 0.004
ρ< ρmax O.k
1.4 1.4
Asminimum= bw d = × 300 × 550 = 525 mm2
fy 400
As > Asminimum o.k
As × fy 942 × 400
a= = = 59.1 mm
0.85fc` × b 0.85 × 25 × 300
a 59.1
c= = = 69.5 mm
β1 0.85
dt − c 550 − 69.5
𝜀𝑡 = × 𝜀𝑢 = 69.5
× 0.003 =20.7 × 10-3
c
𝜀𝑡 > 0.005
∅=0.9
𝑎 59.1
∅Mn= ∅As × fy(d − ) = 0.9 × 942 × 400 × (550 − ) × 10-6 = 176 kN.m
2 2
Pu × L 100 × 5
Mu = = =125 kN.m ∅Mn > Mu the section is O.k ∎
4 4

Lec. Hasanain M. Al-Musawi Reinforced Concrete Design I Page 4


Chapter Two: Analysis of Singly Reinforced Rectangular Beam 3rd Stage

Example 2: Check the adequacy for the beam below according to ACI
requirement, if the beam is subjected to uniform dead load (3) kN/m (without
self-weight) and uniform live load (2) kN/m, use fc`= 28 MPa and fy = 420 MPa
WD = 3 kN/m (without self-weight), WL = 2 kN/m

3∅25 mm

Solution:
π π
As = n × × D2 = 3 × × 252 = 1472.6 mm2
4 4
∅bar 25
D = h − cover−stirrups− = 600 − 40−10− = 537.5 mm
2 2
As 1472.6
ρ= = = 6.85 × 10-3
bd 400 × 537.5
f`c 𝜀𝑢 28 0.003
ρmax = 0.85β1 = 0.85 × 0.85 × × = 0.0206
fy 𝜀𝑢 + 0.004 420 0.003+0.004
ρ< ρmax O.k
1.4 1.4
As minimum= bwd = × 400 × 537.5 = 716.67 mm2
fy 420
As > As minimum
As fy 1472.6 × 420
a= = = 64.96 mm
0.85fc`b 0.85 × 28 × 400
𝑎 64.96
c= = =76.43 mm
β1 0.85
dt−c 537.5−76.43
εt = 𝜀𝑢 = × 0.003 = 0.018
c 76.43
𝜀𝑡 = 0.018 > 0.005
∅ = 0.9
𝑎 64.96
∅Mn= ∅Asfy(d − ) = 0.9×1472.6 × 420× (537.5 − ) ×10-6 = 281.1kN.m
2 2
Find Mu
Wu × ℓ2
Mu =
8
Wu = 1.2WD + 1.6WL
WD self-weight = γ × b × d = 24 × 0.4 × 0.6 = 5.76 kN/m
WD total = 5.76 + 3=8.76 kN/m
Wu= 1.2 × 8.76 + 1.6 × 2=13.712 kN/m
Wu × ℓ2 13.712 × 52
Mu = = = 42.85 kN.m ∅Mn > Mu section is O.K. ∎
8 8

Lec. Hasanain M. Al-Musawi Reinforced Concrete Design I Page 5


Chapter Two: Analysis of Singly Reinforced Rectangular Beam 3rd Stage

Example 3: check the adequacy of the cantilever shown below; the cantilever
is subjected to uniform dead load (3) kN/m (include self-weight) and uniform
live load (4) kN/m, fc`=28 MPa and fy= 420 MPa

3∅20mm

Lec. Hasanain M. Al-Musawi Reinforced Concrete Design I Page 6


Chapter Two: Analysis of Singly Reinforced Rectangular Beam 3rd Stage

Solution:
𝜋 𝜋
As = n × × D2 = 3 × × 202 = 942 mm2
4 4
20
d = 600 − 40−10 − = 540 mm
2
As 942
ρ= = = 6.98 × 10-3
bd 250 × 540
fc` 𝜀𝑢 28 0.003
ρmax = 0.85β1 = 0.85 × 0.85 × × = 0.0206
fy 𝜀𝑢 + 0.004 420 0.003 + 0.004
ρ < ρmax O.k
1.4 1.4
Asminimum= bw d = × 250 × 540 = 450 mm2
fy 420
As > Asminimum o.k
As × fy 942 × 420
a= = = 66.5 mm
0.85fc`× b 0.85 × 28 × 250
𝑎 66.5
c= = = 78.23 mm
β1 0.85
dt−c 540 − 78.23
εt = εu = × 0.003 = 0.0177
c 78.23
𝜀𝑡 > 0.005
∴ ∅ =0.9
a 66.5
∅Mn = ∅Asfy(d − ) = 0.9 × 942 × 420 × (540 − ) ×10-6 = 180.44 kN.m
2 2
Calculate Mu
Wu × ℓ2
Mu =
2
Wu = 1.2WD + 1.6WL = 1.2 × 3 + 1.6 × 4 =10 kN/m
Wu×ℓ2 10×4.82
Mu = = =115.2 kN.m
2 2
∅Mn> Mu section is O.K.∎

Tension side of beam where the


reinforcement shall be put

Lec. Hasanain M. Al-Musawi Reinforced Concrete Design I Page 7


Chapter Two: Analysis of Singly Reinforced Rectangular Beam 3rd Stage

Example 4: check the adequacy of a simply supported beam shown in figure


below when subjected to a factored load of Wu 70 kN/m (including self-
weight), use fc`= 28 MPa and fy = 420 MPa.

Wu=70 kN/m

5∅25 mm
Solution:
π π
As = n × × D2 = 5 × × 252 = 2454 mm2
4 4
25
d = 600 − 40 −10 −25− = 512 mm
2
As 2454
ρ= = = 0.0159
bd 300 × 512
f`c εu 28 0.003
ρmax = 0.85β1 = 0.85 × 0.85 × × = 0.0206
fy εu + 0.004 420 0.003 + 0.004
ρ< ρmax O.k
1.4 1.4
As minimum = bwd = × 300 × 512 = 512 mm2
fy 420
dt
As > As minimum o.k
As × fy 2454 × 420
a= = =144 mm
0.85fc` × b 0.85 × 28 × 300
𝑎 144
c= = =169.83 mm
β1 0.85
dt−c 537.5−169.83
𝜀𝑡 = 𝜀𝑢 = × 0.003 = 6.5×10-3 > 0.005
c 169.83
Then ∅ = 0.9
a 144
∅Mn= ∅As × fy(d − ) = 0.9 × 2454 × 420 × (512 − ) ×10-6 = 408 kN.m
2 2
Wu × ℓ2 70 × 52
Mu = = = 218.75 kN.m ∴ ∅Mn> Mu section is O.K.∎
8 8

Lec. Hasanain M. Al-Musawi Reinforced Concrete Design I Page 8


Chapter Two: Analysis of Singly Reinforced Rectangular Beam 3rd Stage

Example 5: for the precast beam shown in Figure below, the designer intended
to use 4∅20mm ,check the adequacy of the beam according to ACI requirement
, the beam is subjected to uniform dead load (15) kN/m (with self-weight) and
uniform live load (20) kN/m.
Assume in your solution:
• The beam is simply supported.
• fc`= 28 MPa and fy = 420 MPa
• Single layer of reinforcements.
• Beam with 250 mm and effective depth 500 mm.

3D View

Side View

Solution:
π π
As = n × × D2 = 4× × 202 = 1256.63 mm2
4 4
As 1256.63
ρ= = = 0.01
bd 250 × 500
f`c εu 28 0.003
ρmax = 0.85β1 = 0.85 × 0.85 × × = 0.0206
fy εu +0.004 420 0.003+0.004
ρ< ρmax O.k

Lec. Hasanain M. Al-Musawi Reinforced Concrete Design I Page 9


Chapter Two: Analysis of Singly Reinforced Rectangular Beam 3rd Stage
1.4 1.4
As minimum = bwd = × 250 × 500 = 416.7 mm2
fy 420
As > As minimum o.k
As fy 1256.63 × 420
a= = = 88.7 mm
0.85fc`b 0.85 × 28 × 250
a 88.7
c= = =104.35 mm
β1 0.85
dt−c 500−104.35
εt = εu = × 0.003 = 0.0113 > 0.005
c 104.35
Then ∅ = 0.9
𝑎 88.7
∅Mn = ∅Asfy(d − ) = 0.9 × 1256.63 × 420 × (500 − ) ×10-6
2 2
∅Mn = 216.43 kN.m
Calculate Mu
Wu =1.2WD + 1.6WL=1.2 × 15 + 1.6 × 20 = 50 kN/m
Wu × ℓ2 50 × 62
Mu = = =225 kN.m
8 8
∅Mn < Mu the section is not O.K ∎
• Beam dimensions must be increasing or using more reinforcement area.

Lec. Hasanain M. Al-Musawi Reinforced Concrete Design I Page 10


Chapter Two: Analysis of Singly Reinforced Rectangular Beam 3rd Stage

Example 6: a rectangular beam with a width of 305 mm and an effective depth


of 444 m. it is reinforced with 4∅29mm (assume Abar= 645 mm2) if fc`=27.5
MPa and fy = 414 MPa. Check the beam adequacy and compute its design
strength according to ACI requirements.
Solution:
As = n × Abar= 4 × 645 = 2580 mm2
𝐴𝑠 2580
ρ= = = 0.019
𝑏𝑑 305 × 444
f`c εu 27.5 0.003
ρmax = 0.85β1 = 0.85 × 0.85 × × = 0.0205
fy εu + 0.004 414 0.003+0.004
ρ < ρmax O.k
1.4 1.4
As minimum= bwd = × 305 × 444 = 458 mm2
fy 414
As > As minimum o.k
As fy 2580 × 414
a= = =150 mm
0.85fc`b 0.85 × 27.5 × 305
𝑎 150
c= = =176 mm
β1 0.85
dt − c 444 − 176
εt = εu = × 0.003 = 0.00457 < 0.005
c 176
Then:
∅ = 0.483 + 83.3 × 𝜀𝑡
∅ = 0.483 + 83.3 × 0.00457
∅ = 0.86
a 150
∅Mn = ∅Asfy(d − ) = 0.86 × 2580 × 414 × (444 − ) ×10-6
2 2
∅Mn = 339 kN.m ∎

Lec. Hasanain M. Al-Musawi Reinforced Concrete Design I Page 11


Chapter Two: Analysis of Singly Reinforced Rectangular Beam 3rd Stage

Example 7: Check the adequacy of the beam shown below according to ACI
requirement, fc`= 28 MPa ,fy = 420 MPa

3∅30 mm

Solution:
𝜋 𝜋
As = n × × D2 = 3× × 302 = 2120.57 mm2
4 4
d = 400 − 40 − 10−15 = 335 mm
As 2120.57
ρ= = = 0.03165
bd 200 × 335
ρ > ρmax
The section is not O.K and may not be used according to ACI requirements ∎

Lec. Hasanain M. Al-Musawi Reinforced Concrete Design I Page 12