Open navigation menu
Close suggestions
Search
Search
en
Change Language
Upload
Sign in
Sign in
Download free for days
0 ratings
0% found this document useful (0 votes)
78 views
16 pages
Design of Curtain Walls For Wind Loads - Details and Calculations
Uploaded by
YADALA RAVI KUMAR
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download now
Download
Save Design of Curtain Walls for Wind Loads -Details an... For Later
Download
Save
Save Design of Curtain Walls for Wind Loads -Details an... For Later
0%
0% found this document useful, undefined
0%
, undefined
Embed
Share
Print
Report
0 ratings
0% found this document useful (0 votes)
78 views
16 pages
Design of Curtain Walls For Wind Loads - Details and Calculations
Uploaded by
YADALA RAVI KUMAR
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download now
Download
Save Design of Curtain Walls for Wind Loads -Details an... For Later
Carousel Previous
Carousel Next
Download
Save
Save Design of Curtain Walls for Wind Loads -Details an... For Later
0%
0% found this document useful, undefined
0%
, undefined
Embed
Share
Print
Report
Download now
Download
You are on page 1
/ 16
Search
Fullscreen
aM g, Tic, Constructor (epsiraconsratecaa) Civil Engineering Home Design of Curtain Walls for Wind Loads -Details and Calculations Curtain walls are the first structural element that subjected to wind loads. There are cases in which wind loads controls the structural design of curtain walls that may include bluff body aerodynamics analysis, use applicable codes, determination of material geometry and composition cautiously, and consideration of production and placement restriction. ‘The member of structure that greatly influence the design of curtain wall is the floor slabs which provide proper location for the anchorage of curtain walls system. So, curtain walls are arranged like vertical members that attached to the floors slabs and spanning from floor to floor continuously. In this article, the design of curtain walls for wind loads are discussed and explained.vn cmcn_ =: Fig.1: Wind Direction on a Building Fig.2: Curtain Walls on a Building Design of Curtain Walls for Wind Loads Following are the points which are discussed for design of curtain walls for wind loads: osioarancr ghee omega nt ot RYU, sce phen rene reteaenkan, asi pga+ Order for curtain wall structural design and load path + Design of curtain wall glass thickness + Glass pane to frame attachment mechanisms + Structural glass + Importance of scale + Manufacturing and placement considerations + Calculation procedure for Design wind load + Wind load combinations + Safety glazing + Curtain wall analytical models and detailing related to connections, anchors and fastener Order for Curtain Wall Structural Design and Load Path Wind loads are initially imposed on glazing panels then transferred to perimeter supports by glazing panels after that framing members receive wind loads from perimeter supports either directly or indirectly. Frequently, framing members are configured in an orthogonal manner of beam and column mullions which stretched from floor to floor and transfer the wind load to the building structure as it can be seen from Figure-3 and Figure-4, The horizontal elements between vertical mullions are considered as secondary members that transfer a part of dead and wind loads to the vertical elements.Lastly, if openings such as large mechanical ventilation or operable doors and windows are present, then the load transfer path could vary and interior pressure, which may or may not be in harmony with extemal pressure, Is possible to be generated, so taking this possibility into consideration during curtain wall design is a must. ‘icin Giese Tense Anchored Front of lab ‘Wall SystemFixing to slab edge Curtain wall rmullion Building structural elements Cureain wall Glass tenom Fig.4: Curtain Wall System Design of Curtain Wall Glass Thickness The essential factors that influence the design of curtain wall glass thickness involves imposed loads, value of the span, and possibly shading temperature effects which may influence the design for stress capacity. oc eurelvcroghiara-ogsteigrcratwalang lode REY Um, sce paengagein medina pcalentur, mre RaPwreAgeThe strength of flat glasses is substantially affected by the heat treatment applied during glass production process, Requirements set by industry specify the stress limits of three types of glasses namely: annealed, heat strengthened and fully tampered. As far as the controlling influence of loads is concerned, wind loads are commonly the controlling effect, but there are situations in which blast or debris impacts are needed to be considered Performance specification of curtain wall glass that may include deflection limitations and other factors that could affect the glass design, are established by architects It is required to take resident comfortability, interference with adjacent materials, and possible accumulated movements into account while the value of deflection at the center of the glass is specified Regarding boundary condition of glass panels which is employed in the structural analysis, simply supported edges would be assumed for ordinary connections for example dry gasket pocket glazing and silicone glazing. Moreover, lateral pressure on glass panels are considered to be evenly distributed over the whole panel surface. Finally, it is reported that the most widely used glass thickness in the united states for high performance commercial projects is 0.635em. added to that, 2.54cm insulated glass unit is composed of 0.635em outer lite glass plus 1.27cm void plus 0.635cm inner lite glass. ASTM £1300 provide detail procedure regarding the sizing of glass after both geometry and design loads are obtained,Fig. 5: Curtain Wall Glass Thickness and Other Detailing of Curtain Wall System Glass Pane to Frame Attachment Mechanisms Two mecha ms including structural silicone glazing and point support glass will be explored blow Structural Silicone Glazing It is 2 method used to attach glass tiles to the framing perimeter, details of structural silicone glazing are shown in Figure-6. Rubber adhesive is a mere component of structural silicone glazing technique that keep the glass unit against the wind force.There is no mechanical restrain around the edge of glass unit to achieve proper integrity, so experience of structural engineer should be combined with hyper elastic rubber theory to obtain required integrity. Lastly, it is needed to design glass panel as a diaphragm so as to resist in plane wind forces since in plane wind force is possible to occur. eateg chat Sem exkog erase Motel ‘Sec! — Ysera wath ze ‘ac sins ‘Sect Sete Stet ‘lade Tes L | Sette : Details of Structural Silicone Glazing Point Supported Glass Several means have been developed to restrain glass panels since this technique has been developed for example small rectangular clamps, which are termed as patch fittings, applied initially. After that, T-headed bolts, which are inserted into a complete drilled hole in the glass, used to keep glass panels at their position. oc eurelvcroghiara-ogsteigrcratwalang lode REY Um, sce paengagein medina pcalentur, mre RaPwreAgeDusan Cian Yate fe Ws Ls Dea anos Then, countersunk holes are made into the glass in order to prevent the appearance of metal fixture on the outside surface. It should be remembered that, dimensions needed for countersunk hole influences the determination of glass panel thickness. Different types of structural frames are possible to be employed for point support collection for example spider fittings on space frames, cable networks, and tension framing can be applied rather than orthogonal grid of aluminum framing. Fig.7: Point Support Glass osioarancr ghee omega nt ot RYU, sce phen rene reteaenkan, asi pgaFig.8: Countersunk Glass Bolt Support Structural Glass The most usual types of structural glass are the fin glass that work similar to vertical mullions in the curtain wall, Structural glass has been applied in the construction of frames and envelopes of structure such as apple store building. osioarancr ghee omega nt ot RYU, sce phen rene reteaenkan, asi pga 8It should be bore in mind that glass might fail suddenly and destructively, so it is required to carry out accurate evaluation to obtain structural integrity. Lastly, proper stability may be achieved through the provision of large safety factors, sacrificial plies, and extra or alternative load path. Importance of Scale Unlike steel and concrete construction where frequently dimensional measurement values are rounded off to the nearest millimeter, different components of curtain walls are required to be dimensioned and sized substantially accurate since not only do curtain wall contractors want to minimize the utilization of expensive materials but also the intricate fit of detail assemblies needs extreme accuracies to 2mm to a hundred millimeter. It should be known that, deflection plays crucial role In the design of curtain wall. Added to that the deflection of spandre! beams at the perimeter of the building due to live loads would affect curtain wall expansion joints. Manufacturing and Placement Considerations Generally, the desire of designer is to design a curtain wall that withstand wind loads efficiently. However, the design expectations of producers and erectors are the decrease of expensive material utilization and easily installed curtain wall components at construction site, respectively. So, it is required to consider the demands of both manufactures and installers during the design in order to create a successful product at the end In order to achieve the above objective, it is necessary for the designer to make satisfactory decision during the design so as to meet demands of all parties involved in the curtain wall construction.It should be known that, good decisions cannot be made unless adequate information regarding fabrication methods and equipment capabilities are available in addition to understanding construction tolerances, erection rigging, and glazier’s skill level. Calculation Procedure for Design Wind Load on Curtain Walls The design wind load can be found according to ASCE 7-10 (minimum design loads for buildings and other structures), Wind load computation procedures are divided into two sections namely: wind loads for main wind force resisting systems and wind loads on components and cladding. There are four different calculation procedures to compute the former whereas two methods namely Analytical Procedures and Wind Tunnel Procedure are employed to calculate wind loads on components and cladding. Normally, Analytical Procedure is followed to calculate design wind loads for curtain walls, detailed steps for wind load calculation on curtain walls are provide in ASCE 7-10, chapter 30, Part 1 to Part 6. Wind Load Combinations Wind load combinations are also provided in ASCE 7-10, and in the majority of cases the following wind combination provided below is applied because it creates the most critical situation W,=1 Dead Load+1 Wind Load (Equation-1) Safety GlazingThere are several con ‘ns in which the safety of glazing should be explored, and there are cases in which the design for safety glazing would surpass the design of curtain wall for wind loads. generally, necessary safety measures and techniques are provided in applicable codes. Glass in fire rated assemblies, overhead glazing, glass in doors and operable windows, and Glass adjacent to pedestrian walking surfaces are examples of conditions in which safety glazing need to be considered. Curtain Wall Analytical Models and Detailing Related to Connections, Anchors and Fastener Visualizing three-dimensional curtain wall when it is subjected to wind loads and anticipate load distribution and the response of curtain wall to the influences of the wind is a crucial key to a well performed curtain wall design. It is required to have necessary expertise and experience in order to create a model that simulate the behavior of curtain wall. Moreover, there are some essential data that should be achieved otherwise analytical models cannot be generate, for example loads and geometrical parameters and mechanical properties of materials Curtain wall analytical models and detailing will be explained in the following sections: Conversion from Dynamic Pressure to Equivalent Static Pressure Bernoulli's equation is used to change dynamic wind pressure to equivalent static pressure and this pressure is exerted on the surface of glazing perpendicularly. Primary and secondary framing elements are analyzed applying a local uniformly distributed lateral loads and triangular load patterns respectively.Free Body Diagrams It is considered to be the most suitable method to represent curtain wall structural behavior. Commonly, vertical mullions (primary frame members) are analyzed like continuous beams spanning from floor to floor with uniformly distributed load, When greater accuracy is required, each primary frame space or bay would be analyzed utilizing trapezoidal or triangular load pattems. Horizontal beams (secondary frame members) are analyzed as simply supported beams with trapezoidal or triangular loads pattem. Both vertical and horizontal framing elements along with their free body diagrams are illustrated in Figure-9. ITH ry Fig.9: Curtain Wall Free Body Diagram Finite Element Analysis ositearancer ghar omega RIT 9 hengacoham,nedureph roto cnglgepiirenge wsThree dimensional models of curtain wall can be generated using finite element programs such as ANSYS which can represent most of curtain wall conditions accurately. Modeling of boundary conditions are commonly the most adventurous task since perimeters frequently contain flexible supports and gaskets. Additionally, it should be bore in mind that suitable constant physical properties be used for materials such as glass or aluminum, Connection Assemblies The design of connection assemblies is assumed to be the most difficult task of curtain wall design. Modeling of boundary conditions of connection assemblies are based on personal believes and feeling in most cases. Nonetheless, connection assembly models should be created to represent the transfer of loads one member to another one. Mechanical connections that make use of weld or fastener are modeled as rigid bodies with geometry of shifted loads to specify torsion and overturning actions. Anchor Designs and Embeds There are various anchors and embeds that designer need to familiar with in order to select the best type of anchor for the present condition. Examples of anchors are welded steel, bolts, and slotted channels. The slotted channels are widely employed in high performance curtain wall systems. Broad range of post- Installed anchors are specified so as to offer flexibility for missing embeds or tolerances.Communication between structural engineer and curtain wall designer is needed so as to specify anchor design assumption and determine the effect of loads and moments imposed on structure by curtain walls. Finally, it is required to make rooms for structural movement at anchor-wall interface, Read More: Types of Curtain Wall System - its Details, Functions and Advantages (nttps://theconstructor.org/building/curtain-wall-system-types-details/13676/) Types of Glazing Panels, Methods and Construction Details (https://theconstructor.org/ouilding/glazing- panels-types-methods-construction/17626/) Functional Requirements of Walls in Building Construction (https://theconstructor.org/structural- engg/functional-requirements-walls-building-construction/13978/) ©2017 The Constructor
You might also like
Structural Calculation of Curtain Wall
PDF
100% (26)
Structural Calculation of Curtain Wall
118 pages
Advanced Glazing Systems
PDF
100% (1)
Advanced Glazing Systems
45 pages
Window Wall Wall Type
PDF
No ratings yet
Window Wall Wall Type
34 pages
Curtain Wall Design
PDF
83% (6)
Curtain Wall Design
144 pages
Paseo Curtain Wall Strutural Calculation Ver. 2 March 18 2020 PDF
PDF
100% (1)
Paseo Curtain Wall Strutural Calculation Ver. 2 March 18 2020 PDF
93 pages
Structural Design of Stick Curtain Walling-Sample Calculations
PDF
100% (1)
Structural Design of Stick Curtain Walling-Sample Calculations
8 pages
40+ Construction Tools List With Images For Building Construction PDF
PDF
No ratings yet
40+ Construction Tools List With Images For Building Construction PDF
36 pages
Design of Curtain Walls For Wind Loads - Details and Calculations
PDF
100% (2)
Design of Curtain Walls For Wind Loads - Details and Calculations
9 pages
Curtain Wall Glass Thickness Design
PDF
No ratings yet
Curtain Wall Glass Thickness Design
2 pages
Point Supported Glass Details
PDF
No ratings yet
Point Supported Glass Details
2 pages
Advanced Structural Systems: Curtain Walls
PDF
No ratings yet
Advanced Structural Systems: Curtain Walls
13 pages
Asdasa Sas
PDF
No ratings yet
Asdasa Sas
8 pages
curtainwall reaserch
PDF
No ratings yet
curtainwall reaserch
24 pages
Curtain Wall Design Basics 1
PDF
100% (1)
Curtain Wall Design Basics 1
2 pages
Journal Preventing and Treating Failure in Glazed Curtain Wall Systems
PDF
No ratings yet
Journal Preventing and Treating Failure in Glazed Curtain Wall Systems
8 pages
DAGUSTA SKYLIGHT
PDF
No ratings yet
DAGUSTA SKYLIGHT
12 pages
Structural Glass Walls, Floors and Roofs
PDF
No ratings yet
Structural Glass Walls, Floors and Roofs
4 pages
Kaskel 2012
PDF
No ratings yet
Kaskel 2012
37 pages
Curtain Walling
PDF
No ratings yet
Curtain Walling
23 pages
5 Cladding
PDF
No ratings yet
5 Cladding
122 pages
E85 Catalogue TC 1616
PDF
No ratings yet
E85 Catalogue TC 1616
285 pages
Technical Catalogue: Curtain - Wall System
PDF
No ratings yet
Technical Catalogue: Curtain - Wall System
285 pages
2001 - AR423 - BCT04 - 21 - Glass Construction PDF
PDF
No ratings yet
2001 - AR423 - BCT04 - 21 - Glass Construction PDF
67 pages
Curtain Wall Problems
PDF
100% (6)
Curtain Wall Problems
20 pages
Curtain Wall Systems
PDF
91% (11)
Curtain Wall Systems
28 pages
Building Construction: Report On
PDF
No ratings yet
Building Construction: Report On
15 pages
Assignment-2 (Arshnoor Singh)
PDF
No ratings yet
Assignment-2 (Arshnoor Singh)
64 pages
CH 3
PDF
No ratings yet
CH 3
25 pages
Curtain Walls
PDF
No ratings yet
Curtain Walls
34 pages
Curtain Wall
PDF
No ratings yet
Curtain Wall
18 pages
Curtain Wall (Revise1)
PDF
No ratings yet
Curtain Wall (Revise1)
8 pages
JGJ102-2003 - English Version (Verified) PDF
PDF
No ratings yet
JGJ102-2003 - English Version (Verified) PDF
63 pages
The Role of The Building Façade - Curtain Walls: Dudley Mcfarquhar, PH.D, P.E
PDF
No ratings yet
The Role of The Building Façade - Curtain Walls: Dudley Mcfarquhar, PH.D, P.E
11 pages
Construction Technology Ii Curtain Walling Assignment
PDF
No ratings yet
Construction Technology Ii Curtain Walling Assignment
7 pages
Desgn of GLZNG
PDF
No ratings yet
Desgn of GLZNG
6 pages
Glazing PDF
PDF
No ratings yet
Glazing PDF
20 pages
Building Design System: Assignment: Curtain Wall
PDF
No ratings yet
Building Design System: Assignment: Curtain Wall
9 pages
Suspend, Cladding, Curtain
PDF
No ratings yet
Suspend, Cladding, Curtain
19 pages
01 - Curtain Wall
PDF
No ratings yet
01 - Curtain Wall
117 pages
Curtain Wall
PDF
No ratings yet
Curtain Wall
10 pages
Curtain Wall (Jaskirat)
PDF
No ratings yet
Curtain Wall (Jaskirat)
29 pages
Curtain Glazing
PDF
No ratings yet
Curtain Glazing
22 pages
Week 11 - Glass Part 2 - 2023. Full Page
PDF
No ratings yet
Week 11 - Glass Part 2 - 2023. Full Page
71 pages
BE_Struc Calc_Glass Wall & Ceiling _WGP-01_R0(10.02.25)
PDF
No ratings yet
BE_Struc Calc_Glass Wall & Ceiling _WGP-01_R0(10.02.25)
115 pages
Curtain Wall Types and Their Uses
PDF
No ratings yet
Curtain Wall Types and Their Uses
19 pages
Sem 5 - Curtain Wall - 2022
PDF
No ratings yet
Sem 5 - Curtain Wall - 2022
31 pages
Curtain Wall Issues Problems and Solutions
PDF
No ratings yet
Curtain Wall Issues Problems and Solutions
15 pages
Presentation: REPORT .. ON
PDF
No ratings yet
Presentation: REPORT .. ON
32 pages
Commercial Buildings' Curtain Wall Cladding
PDF
100% (1)
Commercial Buildings' Curtain Wall Cladding
3 pages
Advanced Building Technology Lecture 7
PDF
No ratings yet
Advanced Building Technology Lecture 7
40 pages
BC Cladding and Facing
PDF
No ratings yet
BC Cladding and Facing
10 pages
GLASS STRUCTURE Msoffice
PDF
No ratings yet
GLASS STRUCTURE Msoffice
15 pages
Structural Design of A Glass Facade
PDF
No ratings yet
Structural Design of A Glass Facade
6 pages
Methods To Reduce Efflorescence in Newly Constructed Masonry Walls
PDF
No ratings yet
Methods To Reduce Efflorescence in Newly Constructed Masonry Walls
7 pages
Different Failures in RCC Building Structures - Case Studies
PDF
No ratings yet
Different Failures in RCC Building Structures - Case Studies
7 pages
18 Types of Fixtures and Fastenings For Doors and Windows
PDF
No ratings yet
18 Types of Fixtures and Fastenings For Doors and Windows
14 pages
Sl. No. Description Page No
PDF
No ratings yet
Sl. No. Description Page No
6 pages
Is 3873 1993
PDF
No ratings yet
Is 3873 1993
16 pages