ALL RIGHT RESERVED.

THIS WORK IS COPYRIGHT AND REMAINS


THE PROPERTY OF WEBBER DESIGN PTY LTD. NO PART OF THIS
WORK SHALL BE REPRODUCED OR COPIED IN ANY FORM OR BY
MEANS (GRAPHIC, ELECTRONIC OR MECHANICAL, INCLUDING
PHOTOCOPYING, RECORDING OR INFORMATION RETRIEVAL
SYSTEMS) WITHOUT THE PERMISSION OF WEBBER DESIGN PTY
GENERAL FOUNDATIONS: FORMWORK: REINFORCEMENT: LTD.

1. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL ARCHITECTURAL AND OTHER CONSULTANTS 1. THE FOUNDATION IS DESIGNED BASED ON PRELIMINARY GEOTECHNICAL REPORT NUMBER P1780_01 BY 1. DESIGN OF FORMWORK AND SUPPORTING STRUCTURES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR IN 1. REINFORCEMENT IS TO BE MANUFACTURED IN ACCORDANCE WITH AS/NZS 4671 AND AS 1302 AND SHALL DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS
DRAWINGS. MORROW GEOTECHNICS PTY. LTD. DATED 1 NOVEMBER 2019. MORROW GEOTECHNICS PTY. LTD ACCORDANCE WITH AS 3610. BE FIXED AS SHOWN ON REINFORCING PLAN.
SHALL BE ENGAGED TO QUALIFY AND ASSESS THE SUITABILITY OF THE FOUNDATION MATERIAL PRIOR TO Rev Description Eng Draft Date
2. THESE ENGINEERING DRAWINGS HAVE BEEN PREPARED FROM INFORMATION AVAILABLE AT THE TIME, AS PLACING CONCRETE. 2. REFER OTHER CONSULTANTS DOCUMENTATION FOR ADDITIONAL FIXING REQUIREMENTS. 2. MATERIAL IS INDICATED BY THE FOLLOWING SYMBOLS
INFORMATION MAY BE SUBJECT TO CHANGE PRIOR TO OR DURING CONSTRUCTION, THE CONTRACTOR IS R10 DENOTES 10mm DIAMETER HOT ROLLED PLAIN ROUND BAR T1 ISSUED FOR TENDER BT SB 13.12.19
REQUESTED TO ADVISE THE ENGINEER WHERE DIFFERENCES OCCUR. 2. THE BUILDER TO STUDY AND IMPLEMENT ALL RECOMMENDATIONS OUTLINED IN THE GEOTECHNICAL 3. MINIMUM STRIPPING TIMES: N12 DENOTES 12mm DIAMETER HOT ROLLED DEFORMED BAR T2 ISSUED FOR CONSTRUCTION REVIEW RA SB 08.10.20
REPORT AND OTHER RELEVANT RECOMMENDATIONS FROM BUILDING TECHNOLOGY FILE 18 (FORMERLY WALLS AND COLUMNS 7 DAYS SL82 DENOTES SQUARE WELDED WIRE FABRIC
3. THESE DRAWINGS SHALL NOT BE USED FOR FINAL SET OUT OF THE PROJECT UNLESS SPECIFICALLY STATED. KNOWN AS CSIRO NOTE 10-9). RL918 DENOTES RECTANGULAR WELDED WIRE FABRIC T3 ISSUED FOR CONSTRUCTION REVIEW RA SB 06.11.20
GENERAL FLOOR 14 DAYS
4-L12TM DENOTES 4 MAIN WIRES OF 12mm TRENCH MESH T4 ISSUED FOR CERTIFICATION RA SB 12.11.20
4. ALL WORKS SHALL COMPLY WITH THE CURRENT, RELEVANT SAA CODES AND THE BUILDING CODE OF 3. REFER GEOTECHNICAL REPORT FOR SITE CLASSIFICATION IN ACCORDANCE WITH AS 2870. 4. FORMWORK SHALL BE DESIGNED, ERECTED, SUPPORTED, BRACED AND MAINTAINED TO SAFELY SUPPORT ALL N DEFORMED BAR OF GRADE 500
T5 ISSUED FOR CERTIFICATION RA SB 02.12.20
AUSTRALIA. THE FOLLOWING RELEVANT STANDARDS SHALL BE READ AS PART OF THESE GENERAL NOTES VERTICAL AND LATERAL LOADS THAT WILL BE APPLIED UNTIL SUCH LOADS CAN BE SUPPORTED BY THE R ROUND BAR OF GRADE 250
AND COPIES SHALL BE KEPT ON SITE WITH THE CONTRACTUAL DOCUMENTS: 4. EXISTING ADJACENT FOOTINGS SHALL NOT BE UNDERMINED. NEW FOOTING FOUNDING DEPTH SHALL CONCRETE STRUCTURE. L LOW DUCTILITY BAR OF GRADE 500 T6 ISSUED FOR CONSTRUCTION REVIEW RA SB 23.02.21
MATCH, BUT NOT EXCEED, ADJACENT FOOTING FOUNDING DEPTH. IN THE EVENT THAT UNDERPINNING IS SL SQUARE WELDED WIRE OF GRADE 500 C1 ISSUED FOR CONSTRUCTION RA SB 25.02.21
AS 1554 - SAA WELDING CODE (ALL PARTS) REQUIRED PLEASE CONTACT THIS OFFICE. 5. BACK PROP SLABS AND BEAMS TO ENGINEERS APPROVAL FOR A MINIMUM OF 28 DAYS AFTER CASTING. RL RECTANGULAR WELDED WIRE MESH OF GRADE 500
AS 1684 - SAA NATIONAL TIMBER FRAMING CODE (ALL PARTS) C2 ISSUED FOR CONSTRUCTION AV SB 04.03.21
AS 1720 - SAA TIMBER CODE (ALL PARTS) 5. ANY EXCAVATION WORKS FOR CONSTRUCTION OF FOOTINGS OR RETAINING WALLS SHALL NOT ENCROACH 6. STRIPPING AND BACK PROPPING TIMES MAY BE REDUCED UPON RECEIPT OF STRENGTH TEST RESULTS AT THE 3. THE BAR SIZE INDICATED BY A NUMBER AFTER THE ABOVE SYMBOL, WHICH INDICATES THE BAR DIAMETER C3 ISSUED FOR CONSTRUCTION AV SB 06.04.21
AS 2870 - SAA RESIDENTIAL SLABS AND FOOTINGS BEYOND 45° LINE OF INFLUENCE. DISCRETION OF THE ENGINEER. IN MILLIMETERS. REFER TO NOTE 2 ABOVE FOR EXAMPLE.
AS 3600 - SAA CONCRETE STRUCTURES CODE C4 ISSUED FOR CONSTRUCTION AC SB 25.05.21
AS 3610 - SAA FORMWORK FOR CONCRETE CODE 6. UNLESS NOTED OTHERWISE, WHEREVER A NEW FOOTING IS LOCATED CLOSE TO AN EXCAVATION, BATTER, 7. PRE-CAMBER ALL FORMWORK: 4. GRADE 500 REINFORCEMENT TEST CERTIFICATES SHALL BE AVAILABLE FOR WEBBER DESIGN PTY. LTD. FOR
AS 3700 - SAA MASONRY STRUCTURES CODE EXISTING FOOTING, EXISTING SERVICE OR NEW SERVICE WHICH IS DEEPER THAN THE NEW FOOTING; THE SLABS AND BEAMS SPAN / 600 APPROVAL PRIOR TO FIXING UPON REQUEST.
AS 3798 - SAA GUIDELINES FOR EARTHWORKS FOR COMMERCIAL AND RESIDENTIAL DEVELOPMENTS EXCAVATION FOR THE NEW FOOTING SHALL BE DEEPENED AND BACKFILLED WITH BLINDING CONCRETE CANTILEVERS SPAN / 200
AS 4100 - SAA STEEL STRUCTURES CODE AS SPECIFIED. THE ENGINEER SHALL BE NOTIFIED IF IN DOUBT. 5. COVER TO REINFORCEMENT TO BE (UNLESS NOTED OTHERWISE):
AS 4600 - SAA COLD-FORMED STEEL STRUCTURE 8. ENSURE DECK IS CLEANED OF ALL DEBRIS PRIOR TO CONCRETING. DRAWING REFERENCE REFERENCE No.
NCC 2019 - NATIONAL CONSTRUCTION CODE 7. THE STRUCTURAL DESIGN HAS BEEN UNDERTAKEN BASED ON THE FOOTING ALLOWABLE BEARING TYPE INTERNAL FACES EXTERNAL FACES DRAWING INDEX S000
PRESSURES RECOMMENDED BY THE GEOTECHNICAL REPORT. 9. CONTRACTOR SHALL PROVIDE SOLEBOARDS TO ALL SUPPORT SYSTEM LEGS BEARING ON GROUND OR
5. ALL STRUCTURAL WORK SHOWN ON THESE DRAWINGS SHALL BE SUBJECT TO THE APPROVAL OF THE SUSPENDED FLOOR AND ENSURE THAT THE GROUND OR SUSPENDED FLOOR IS CAPABLE OF SUPPORTING THE FOOTINGS / PILE CAPS - 50 GENERAL NOTES S001-S002
ENGINEER 8. THE SITE SHALL BE STRIPPED, TRIMMED AND GENERALLY PREPARED IN ACCORDANCE WITH THE MAXIMUM DESIGN LEG LOAD. RETENTION S010-S029
GEOTECHNICAL REPORT. IN ALL CASES THE SITE SHALL BE STRIPPED OF ALL VEGETATION IN BUILDING COLUMNS 25 35 CONCRETE COLUMNS S800-S819
6. PERIODICAL INSPECTIONS ARE REQUIRED TO BE PERFORMED BY A DULY APPOINTED INSPECTOR FROM AREAS. NO VEGETATION OR ORGANIC MATTER SHALL EXIST IN THE SOIL STRATA BELOW FOOTINGS OR 10. CONTRACTOR SHALL MONITOR FORMWORK DURING CONCRETE PLACEMENT AND ADJUST FORMWORK IF
"WEBBER DESIGN PTY. LTD.". THESE INSPECTIONS ARE REQUIRED TO BE PERFORMED IN ACCORDANCE WITH GROUND LEVEL.
IN-SITU WALLS S820-S879
REQUIRED. WALLS 25 35
SCOPE OF INSPECTIONS IN SPECIFICATIONS PREPARED. THE INSPECTING ENGINEER IS RESPONSIBLE FOR SLAB ON GROUND DETAILS S950-S951
PERFORMING MONITORING INSPECTIONS ONLY AND NOT SITE WORKS SUPERVISION, WHICH SHALL BE THE 9. THE CONTRACTOR IS TO ALLOW FOR ANY ADDITIONAL INVESTIGATIONS AND MATERIAL TESTING DEEMED 11. CONTRACTOR TO VERIFY THAT ALL PROPRIETARY MANUFACTURED FORMWORK (PROPS, FRAMES, JACKS AND RETAINING WALLS 50 50 SUSPENDED CONCRETE SLABS S960-S962
SOLE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR TO PROVIDE A MINIMUM OF 24 HOURS NOTICE NECESSARY TO FURTHER ESTABLISH SITE CONDITIONS TO ACHIEVE THE REQUIRED FOUNDATION BRACING ETC.) TO BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS. POST TENSIONING DETAILS S965-S966
PRIOR TO INSPECTION. PARAMETERS. 35 40
BEAMS R.C. STAIR DETAILS S970
7. SPECIFICATIONS OR INSTRUCTIONS ON DRAWINGS TAKE PRECEDENCE OVER THESE NOTES. 10. ALL FOUNDATION MATERIALS SHALL BE VERIFIED BY TESTING AT THE EXPENSE OF THE CONTRACTOR AND CONCRETE: MASONRY DETAILS S980-S981
SUSPENDED SLABS 25 40
SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO THE PLACEMENT OF MEMBRANE, BRICK WALL DETAILS S985
1. CONTRACTOR IS TO ENSURE THAT ALL CONCRETE ELEMENTS ARE CONSTRUCTED TO THE MINIMUM SIZE SHOWN
8. DO NOT SCALE FROM DRAWINGS. REINFORCEMENT OR CONCRETE. SLABS ON GROUND 30 40
ON DRAWINGS.
9. DESIGN PARAMETERS ADOPTED FOR THIS PROJECT ARE AS FOLLOWS: 11. UNLESS OTHERWISE NOTED, THE SITE SHALL BE FILLED WITH APPROVED WELL GRADED SAND.
2. SIZES OF CONCRETE ELEMENTS DO NOT INCLUDE APPLIED FINISHES.
6. HOOKS AND COGS SHALL COMPLY WITH AS 3600 UNLESS OTHERWISE SHOWN. SLOPES OF CRANKS ARE
DESIGN LIFE 50 YEARS 12. NO EXCAVATED MATERIAL FROM SITE SHALL BE SUITABLE FOR BACKFILL WITHOUT PRIOR GEOTECHNICAL NOT TO EXCEED 1 IN 6.
3. APPROVED INTERNAL VIBRATORS SHALL BE USED TO COMPACT CONCRETE. CAVITY FILL SHALL BE RODDED.
ENGINEERS APPROVAL.
WIND LOADS 7. REINFORCE SLAB RE-ENTRANT CORNERS WITH 2N16 x 1500 BARS PLACED AT 45 DEGREES TIED TO THE
4. ALL CONCRETE IS TO BE CURED FOR 14 DAYS MINIMUM AFTER POURING OR APPROVED PROPRIETARY SYSTEM.
REGION A2 13. COMPACT FOUNDATION MATERIAL AND BACKFILL IN LAYERS NOT EXCEEDING 300mm INTERMEDIATE INSIDE OF THE REINFORCEMENT.
UNLESS OTHERWISE NOTED. SLABS SHALL BE THOROUGHLY WETTED, THEN COVERED FOR A MINIMUM OF 7
TERRAIN CATEGORY 3 LAYERS TO 95% MODIFIED MAXIMUM DRY DENSITY IN ACCORDANCE WITH AS 1289. PROVIDE
DAYS WITH 0.2MM THICK POLYTHENE SHEETING, WHICH SHALL BE SECURELY FIXED AGAINST TRAFFIC AND WIND
SHIELDING Ms 1 COMPACTION TEST RESULTS PRIOR TO PROCEEDING. 8. MINIMUM LAPS FOR:
C4 AND OVERLAPPED 300MM MINIMUM AT JOINTS.
GUST WIND SPEED Vu 46m/s (37m/s FOR SLS) MESH OVERLAP 2 OUTERMOST TRANSVERSE BARS
TOPOGRAPHY Mt 1.0 14. COMPACTION METHODOLOGY SHALL BE VERIFIED BY THE CONTRACTOR TO CAUSE NO DAMAGE TO N & R BARS 50 BAR DIAMETERS UNLESS NOTED OTHERWISE
5. CONCRETE SHALL BE READY MIXED BY AN APPROVED SUPPLIER AS BELOW (UNLESS NOTED OTHERWISE):
ADJACENT STRUCTURES.
9. REINFORCEMENT SHOWN DIAGRAMMATICALLY AND NOT NECESSARILY IN TRUE PROJECTION
EARTHQUAKE LOADS (AS1170.2007) LOWEST LEVEL FOOTINGS SHALL BE POURED FIRST. NO HEIGHT EXCEEDING HALF THE CLEAR DISTANCE MAX. COURSE
15. ELEMENT SLUMP (mm) MIN. f'c AT 28 DAYS (MPa)
SITE SUB CLASS Be BETWEEN FOOTINGS WITH DIFFERENT LEVEL IS PERMITTED. AGGREGATE (mm) 10. ALL REINFORCEMENT SHALL BE SECURELY SUPPORTED IN ITS CORRECT POSITION DURING CONCRETING AT
HAZARD FACTOR Z 0.08 PAD 800mm MAXIMUM WIDTH FOR BARS AND 600mm MAXIMUM WIDTHS FOR MESH.
80 20 N32
BCA IMPORTANCE LEVEL 2.0 16. ALL FOOTINGS TO BE LOCATED CENTRALLY UNDER WALLS AND COLUMNS UNLESS OTHERWISE NOTED. FOOTINGS BAR CHAIRS IN REINFORCED CONCRETE ARE TO BE IN ACCORDANCE WITH AS/NZS 2425:2015
PROBABILITY FACTOR, Kp 1.0 STRIP
EDC II BLINDING CONCRETE OF 15MPa SHALL BE PROVIDED TO BACKFILL IN ANY NECESSARY OVER EXCAVATION 80 20 N32 11. MOVE AFFECTED REINFORCEMENT TO EITHER SIDE OF HOLES IN SLAB UNLESS NOTED OTHERWISE.
FOOTINGS
17. TO ACHIEVE THE REQUIRED BEARING CAPACITY.
SUPERIMPOSED DEAD LOADS (kPa) SLAB ON GROUND
80 20 N32 12. WELDING OF REINFORCEMENT SHALL NOT BE PERMITTED WITHOUT THE PRIOR APPROVAL OF THE
RESIDENTIAL 1.5 INTERNAL
PRIOR TO PLACING CONCRETE, ALL FOUNDATIONS ARE TO BE FREE OF WATER OR LOOSE DELETERIOUS ENGINEER. THE CONTRACTOR SHALL ESTABLISH A WELDING PROCEDURE SUBMITTED TO THE ENGINEER
SUBSTATION 0.5 MATERIAL. SLAB ON GROUND FOR APPROVAL. ALL WELDING OF REINFORCEMENT SHALL BE IN ACCORDANCE WITH AS 1554 PART 3.
18. 80 20 N40
LOADING DOCK 0.5 EXTERNAL
TERRACES 2.0 RAFT SLABS AND SLABS ON GROUND SHALL BE UNDERLAIN BY HEAVY DUTY SEALED POLYTHENE VAPOUR 13. ALL WELDING TO BE CARRIED OUT BY A QUALIFIED AUSTRALIAN SUPERVISOR, WELDING QUALIFICATION TO
CARPARK 0.5 CAVITY FILLS 100 10 N20
19. BARRIER. BE PRESENTED UPON REQUEST. MAXIMUM WELD SIZE TO BE 4 CFW EACH PASS, WITH E48XX ELECTRODE.
BALCONY 1.5 WALLS 80 20 (REFER SCHEDULE) THE CONTRACTOR SHALL ENGAGE A WELDING INSPECTOR TO INSPECT THE PROCEDURE AND SITE WELDS.
LIVE LOADS (kPa) BORED PIERS AND PILES ARE TO BE CONSTRUCTED TO WITHIN 75mm OF THE DESIGNATED PLAN COLUMNS 80 20 (REFER SCHEDULE)
RESIDENTIAL 1.5 20. LOCATION. TRUE VERTICALITY OF PILES SHALL BE 1/100 OF THE TOTAL LENGTH OF THE PILE. THE 14. REINFORCEMENT IS NOT PERMITTED TO BE HEATED ABOVE 400 DEGREES
CONTRACTOR SHALL ALLOW FOR AND PROVIDE TEMPORARY LINERS AS REQUIRED TO AVOID COLLAPSE IN INT. SUSPENDED SLABS, N40 FOR R.C (REFER SCHEDULE)
SUBSTATION 7.5 60 20
THE BORED HOLE. BEAMS AND STAIRS S40 FOR P.T. (REFER SCHEDULE) 15. NO WELDS PERMITTED WITHIN 50mm OF BAR BENDS.
LOADING DOCK 7.5
NON-TRAFFICABLE ROOF 0.25 EXT. SUSPENDED SLABS, N40 FOR R.C (REFER SCHEDULE)
60 20 16. ABBREVIATIONS USED IN DRAWINGS:
TERRACES 2.0 ALL GROUND SLABS ARE TO BE UNDERLAIN BY A 0.2mm VAPOUR BARRIER MEMBRANE ATOP 100mm BEAMS AND STAIRS S40 FOR P.T. (REFER SCHEDULE)
CARPARK 2.5 21. NOMINAL ROAD BASE MATERIAL.
PROPRIETARY FORMWORK (REFER SCHEDULE) EW EACH WAY
BALCONY 2.0 180 10
THE RELOCATION OF THE ISOLATED FOOTINGS WITHIN THE VICINITY OF THE TPZ WILL REQUIRE WALLS (RITEK, DINCEL, NF NEAR FACE
FRL LIMITS REDESIGN OF FOUNDATIONS AND IS SUBJECTED TO APPROVAL BY ARCHITECT AND BUILDER. AFS, ETC.) FF FAR FACE
CARPARK 120/120/120 IT IS RECOMMENDED THAT THE ROOTS BE INVESTIGATED AND MAPPED OUT BY AN ARBORIST TO EF EACH FACE
RESIDENTIAL 90/90/90 DETERMINE THE EXTENT AND IMPACT OF THE EXISTING ROOTS WITHIN THE ZONE. 6. TYPE 'GP' PORTLAND CEMENT SHALL BE USED UNLESS OTHERWISE NOTED. CTR CENTRAL
LIFT / STAIR CORE 120/120/120 T TOP
7. ADMIXTURES SHALL NOT ADVERSELY AFFECT THE SPECIFIED CONCRETE PROPERTIES. DO NOT USE ADMIXTURES UNLESS B BOTTOM
APPROVED LG BAR LENGTH (NOT INCLUDING COG)
10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE STRUCTURE AND ADJACENT STRUCTURES PILING BY THE ENGINEER. THE USE OF CALCIUM CHLORIDE, CHLORIDE ADMIXTURES AND SILICA FUME OR FLY ASH AS CEMENT CTS CENTRES
IN A STABLE CONDITION. NO PART OF THESE STRUCTURES SHALL BE OVERSTRESSED UNDER CONSTRUCTION SUBSTITUTES ARE NOT PERMITTED. REINF. REINFORCEMENT
1. ALL PILES SHALL BE DESIGNED IN INSTALLED IN ACCORDANCE WITH CURRENT SAA CODES AS 1170, AS
ACTIVITIES. SEC. SECONDARY
2159 AND AS 3600.
8. UNLESS NOTED OTHERWISE, CONCRETE STRENGTH SHALL BE GRADE N32 WITH:
11. ALL PROPS AND FORMWORK FOR FLOOR BEAMS AND SLABS SHALL BE REMOVED BEFORE CONSTRUCTION OF 17. SAFETY MESH TO BE SUPPLIED FOR DEPTHS GREATER THAN 500mm, AND INSTALLED AS REQUIRED ON
2. THE PILING CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT ALL PILES ARE INSTALLED TO THE MINIMUM CEMENT CONTENT OF 320kg/m³
ANY MASONRY WALLS OR PARTITIONS ON THE FLOOR. MAXIMUM WATER CONTENT OF 165l/m³ SITE.
REQUIREMENTS OF;
COARSE AGGREGATE SIZE OF 20mm, AND
12. ALL NON LOAD-BEARING WALLS SHALL BE KEPT 20mm CLEAR OF THE UNDERSIDE OF SLABS AND BEAMS MAXIMUM SHRINKAGE AT 56 DAYS 600 MICROSTRAINS
- STRUCTURAL DRAWINGS
UNLESS NOTED OTHERWISE. - PILING SPECIFICATION
- AUSTRALIAN STANDARDS: AS 1170 (SAA LOADING CODE), 9. FOR HIGH STRENGTH CONCRETE (f'c EXCEEDING 40MPa), THE MIX DESIGN SHALL INCLUDE THE FOLLOWING:
13. CONTRACTOR SHALL RECORD ALL VARIATIONS TO THE DRAWINGS AND BE RESPONSIBLE FOR PRODUCING AS- LOW WATER / CEMENT RATIO
AS 2159 (SAA PILING CODE), AS 3600 (SAA CONCRETE
BUILD DRAWINGS AT THE COMPLETION OF THE WORK AS REQUIRED. STRUCTURES CODE) AND AS 4100 (SAA STEEL STRUCTURES) LOW CREEP
- GEOTECHNICAL INVESTIGATION REPORT. LOW SHRINKAGE (i.e. 600 AVERAGE MICROSTRAINS AT 56 DAYS)
14. NO PENETRATION, DRILLING OR CHASING IN STRUCTURAL ELEMENTS IS PERMITTED WITHOUT PRIOR LOW HEAT HYDRATION
APPROVAL FROM THE ENGINEER. ALL PILES SHALL BE DESIGNED TO ACCOMMODATE A LOAD ECCENTRICITY OF 75mm DUE TO INSTALLATION SUPER-PLASTICISERS ADDITIVES TO INCREASE SLUMP
3.
TOLERANCES ON SITE. SUPPLEMENTARY CEMENTITIOUS MATERIALS SUCH AS SILICA FUME,
15. ALL PROPRIETARY PRODUCTS SPECIFIED ON THESE DRAWINGS SHALL BE INSTALLED IN STRICT ACCORDANCE FLY ASH AND GROUND GRANULATED BLAST FURNACE SLAG.
WITH THE MANUFACTURERS SPECIFICATIONS. ALTERNATIVE EQUIVALENT PRODUCTS MAY ONLY BE USED THE PILING CONTRACTOR SHALL SUBMIT ALL PILING AND RETENTION DETAILS AND DESIGN CALCULATION
4.
WITH THE APPROVAL OF THE ENGINEER. TO THE ENGINEER FOR REVIEW. ALLOW MINIMUM OF 5 WORKING DAYS FOR REVIEW PRIOR TO SITE 10. CURING IS ESSENTIAL TO PREVENT SELF DESICCATION IN EARLY AGE OF THE CONCRETE.
COMMENCEMENT.
16. CONTRACTOR SHALL SUBMIT TO THIS OFFICE CONSTRUCTION METHODOLOGY, INCLUSIVE OF ALL TEMPORARY 11. DETAILS OF ALL PROPOSED MIX DESIGNS SHALL BE FORWARDED TO THE ENGINEER PRIOR TO INCORPORATION IN THE
ERECTION STRUCTURE PRIOR TO THE COMMENCEMENT OF STEEL INSTALLATION. PILES SHALL BE TESTED IN ACCORDANCE WITH THE SPECIFICATION. PILE TESTS TO BE CARRIED OUT AS WORKS.
5.
FOLLOWS:
17. IT IS A REQUIREMENT THAT ALL BUILDING MATERIALS USED AND INSTALLED ON THE PROJECT MUST BE 12. CAST CONCRETE TO JOINTS SHOWN ON DRAWINGS OR OTHERWISE APPROVED BY THE ENGINEER IN A HIT / MISS PATTERN.
- DYNAMIC TESTING 5%
COMPLIANT WITH THE NATIONAL CONSTRUCTION CODE, THE BUILDING CODE OF AUSTRALIA, THE - CAPWAP 2%
AUSTRALIAN STANDARDS AND ANY OTHER APPLICABLE LAWS OR REGULATIONS. 13. THE ENGINEER SHALL BE NOTIFIED WHENEVER THE CURRENT AMBIENT TEMPERATURE OR THE TEMPERATURE FORECAST
6. THE PILING CONTRACTOR IS RESPONSIBLE FOR SETTING OUT PILE LOCATIONS. FOR THE DAY OF THE CONCRETE POUR EXCEEDS 35 DEGREES. ENGINEER AT HIS / HER DISCRETION MAY OR MAY NOT
BULK EXCAVATION: PERMIT CONCRETE BE POURED DURING THAT DAY.
1. ALL LEVELS, BATTERS, CONTOUR LINES AND LOCATIONS OF EXISTING SERVICES SHOWN ON PLAN ARE 7. ALL PILE DESIGNS MUST INCORPORATE AN ALLOWANCE FOR ANY DOWN-DRAG DUE TO SOFT SOIL
CONSOLIDATION WHERE APPLICABLE. 14. ALL COMPONENTS CAST INTO CONCRETE SHALL BE HOT DIP GALVANISED.
INDICATIVE ONLY AND SHALL BE VERIFIED ON SITE. REFER TO ARCHITECTURAL AND SURVEY PLANS FOR
DETAILS. 15. CONTRACTOR SHALL PROVIDE THE PROJECT ENGINEER 7 AND 28 DAY COMPRESSIVE STRENGTH TEST FOR EVERY 50m³
8. PILES ARE TO BE MONITORED FOR UPWARD HEAVE MOVEMENTS WHERE APPLICABLE. PILES WITH
SIGNIFICANT MOVEMENT MAY REQUIRE TO BE RE-DRIVEN. DELIVERED OR DELIVERY TO SITE. CONCRETE TESTING SHALL COMPLY WITH THE REQUIREMENTS OF AS 1379.
2. THE CONTRACTOR IS TO NOTIFY ALL SERVICE AUTHORITIES AND ARRANGE FOR DISCONTINUANCE OF
SERVICES OR SUPPLY AS APPLICABLE AND CARRY OUT ALL DISCONNECTION OR SEALING OFF OF SERVICES
9. THE DESIGN OF PROPRIETARY BOUNDARY RETENTION SYSTEMS SHALL ENSURE THE SAFETY AND STABILITY 16. PROPOSED LOCATION OF CONSTRUCTION JOINT SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW AND APPROVAL. Key Plan
AND DRAINS AS REQUIRED. SERVICES OR SUPPLY LINES THAT ARE TO BE RETAINED SHALL REMAIN
UNDAMAGED AND GIVEN ALL NECESSARY PROTECTION AS REQUIRED. OF THE SITE AND ADJACENT STRUCTURES AT ALL TIMES.
17. DURING PLACEMENT, CONCRETE FALL HEIGHT SHALL BE RESTRICTED TO
3. THE CONTRACTOR SHALL PROVIDE EFFECTIVE DIVERSION OR REMOVAL OF ALL SURFACE WATER FROM THE
PREPARED SUB-GRADE.
10. PILING CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE PRESENCE OF ALL UNDERGROUND SERVICES
PRIOR TO COMMENCEMENT OF ANY WORKS.
GENERALLY
FOR WALLS EQUAL TO OR
- 1800mm
- 2700mm CONSTRUCTION ISSUE
GREATER THAN 200mm THICK
C:\Users\S. BUDDI\Documents\ROOM LOCAL\WEBBER\WD19112_159 Epping Rd, Macquarie Park\WD19112_159 Epping Rd, Macquarie Park_locaL_Kalyan M.rvt

Status
4. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED ENVIRONMENTAL TREATMENT OF RUNOFF FROM THE 18. TOLERANCE CLASSES TO CONCRETE SURFACES SHALL BE DETERMINED BY A STRAIGHT EDGE PLACED ANYWHERE ON THE
CONSTRUCTION SITE.
SURFACE IN ANY DIRECT AS FOLLOWS: STRUCTURAL DRAWING
CLASS A MAXIMUM DEVIATION FROM 3m STRAIGHT EDGE 3mm
5. THE BULK EXCAVATION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE BULK EXCAVATION PLAN.
CLASS B MAXIMUM DEVIATION FROM 3m STRAIGHT EDGE 6mm
CLASS C MAXIMUM DEVIATION FROM 6m STRAIGHT EDGE 6mm
6. EXCESS EXCAVATIONS SHALL NOT BE PAID FOR AS EXTRA EXCAVATION UNLESS AUTHORISED BY THE SUPER
INTENDENT OR THE ENGINEER. EXCESS EXCAVATION SHALL BE FILLED BY THE CONTRACTOR WITH 3% 19. CONCRETE WORKS REQUIRING WATERPROOFING SHALL INCLUDE WATERPROOF ADMIXTURE AS PER MANUFACTURERS
CEMENT STABILISED SAND.
RECOMMENDATIONS.
7. BULK EXCAVATION BATTERS AROUND THE PERIMETER OF THE SITE ARE TO BE 1V:1.5.H UNLESS OTHERWISE 20. CONCRETE SURFACE SHALL BE FINISHED TO BE COMPLIANT WITH THE SPECIFIC REQUIREMENTS FOR ANY APPLIED
NOTED.
SURFACE FINISHES INCLUDING CARPET TILES, VINYL FLOOR, TILES, ADHESIVES, OTHER SURFACE APPLICATION, ETC. REFER
ARCHITECTURAL SPECIFICATION FOR EXTENT AND FINAL SLAB FINISH REQUIREMENTS.

S T R U C T U R A L E N G I N E E R I N G
SYDNEY OFFICE: MELBOURNE OFFICE:
SUITE 301, LEVEL 3, 19A BOUNDARY STREET LEVEL 2, 31 QUEEN STREET
RUSHCUTTERS BAY, NSW, AUSTRALIA 2011 MELBOURNE, VIC, AUSTRALIA 3000
T: +61 2 9690 2488 T: +61 3 9614 7155
CLIENT

VIMG

PROJECT

159-161 EPPING ROAD


MACQUARIE PARK NSW
2113
TITLE

GENERAL NOTES - SHEET 1


25-05-2021 06:41:36

DATE DESIGNED BY CHECKED BY

OCT 2020 AC AC

SCALES AT B1 DRAWN BY APPROVED BY

SB PK

JOB No. DRAWING No. REV.


PRINT TIME:

19112 S001 C4