Driver Lco 100W 500/700/1050/1400ma Fixc L Snc2 Essence Outdoor Series
Driver Lco 100W 500/700/1050/1400ma Fixc L Snc2 Essence Outdoor Series
Product description
• Independent fixed output LED Driver
• Constant current LED Driver
• Output current 500, 700, 1,050 or 1,400 mA
• Up to 92 % efficiency
• Ambient temperature range of -40 ... +60 °C
• Max. casing temperature tc of 90 °C
• Nominal life-time up to 100,000 h
• 5-year guarantee (conditions at www.tridonic.com)
Properties
• Casing: metal, black
• Type of protection IP67
Interfaces
• Connection: cable 300 mm
Functions
• Protective features (overtemperature, short-circuit, overload,
no-load)
Benefits
• Wide voltage input 100 – 240 V
• Best energy savings due to low stand-by losses and
high efficiency
• Suitable for mains voltage peaks (burst/surge) up to 6 kV
• Double or reinforced insulation
• High number of drivers on 16 A (B) automatic circuit breakers
• Extended vibration damping
• The LED Driver is designed for a life-time stated above under
reference conditions and with a failure probability of less than
10 %
• The wide product range offers common currents for a cost
effective luminaire manufacturing
Typical applications
• For parking lot, high bay, street and road applications
• For linear/area lighting in industry applications
È
Standards, page 3
Wiring diagrams and installation examples, page 3
Only for 500 and 700 mA: Driver LCO 100W 500/700/1050/1400mA fixC L SNC2
essence outdoor series
Technical data
Rated supply voltage 120 – 240 V 181
AC voltage range 100 – 240 V 165
29,1
Mains frequency 50 / 60 Hz 151
29
8
5
Leakage current (at 230 V, 50 Hz, full load) < 500 µA 30
30 tc
THD (at 230 V, 50 Hz, full load) < 10 %
45
5
Output current tolerance2 ±5% 8,1
8
Starting time (at 230 V, 50 Hz, full load) ≤ 0.5 s 36,8 61
Turn off time (at 230 V, 50 Hz, full load) ≤ 0.5 s 305 305 10
10
37,8
Ambient temperature ta -40 ... +60 °C
Storage temperature ts -40 ... +85 °C
Mains burst capability 4 kV
Mains surge capability (between L – N) 4 kV Ordering data
Mains surge capability (between L/N – PE) 6 kV Article Packaging, Packaging, Weight
Type
number5 carton pallet per pc.
Surge voltage at output side (against PE) 2 kV
LCO 100/500/200 fixC L SNC2 28002301 10 pc(s). 420 pc(s). 0.61 kg
Life-time up to 100,000 h
LCO 100/700/143 fixC L SNC2 28002302 10 pc(s). 420 pc(s). 0.61 kg
Guarantee (conditions at www.tridonic.com) 5 years
LCO 100/1050/95 fixC L SNC2 28002303 10 pc(s). 420 pc(s). 0.61 kg
Dimensions L x W x H 181 x 61 x 37.8 mm
LCO 100/1400/71 fixC L SNC2 28002304 10 pc(s). 420 pc(s). 0.61 kg
1. Standards
EN 55015
EN 61000-3-2
EN 61000-3-3
EN 61347-1
EN 61347-2-13
EN 61547
EN 62384
Expected life-time
Type ta 50 °C 55 °C 60 °C
tc 65 °C 70 °C 75 °C
LCO 100/500/200 fixC L SNC2
Life-time >100,000 h 90,000 h 60,000 h
tc 65 °C 70 °C 75 °C
LCO 100/700/143 fixC L SNC2
Life-time >100,000 h 100,000 h 70,000 h
tc 65 °C 70 °C 75 °C
LCO 100/1050/95 fixC L SNC2
Life-time >100,000 h 95,000 h 65,000 h
tc 65 °C 70 °C 75 °C
LCO 100/1400/71 fixC L SNC2
Life-time >100,000 h 100,000 h 70,000 h
The LED Driver is designed for a lifetime stated above under reference
conditions and with a failure probability of less than 10 %.
3. Installation / wiring
120–240 V
50/60 Hz
L
N
PRI
+ LED PE
SEC
– LED
3.2 Connection
Primary Secondary
cable cable
L N PE + –
brown blue green/yellow brown blue
305
10
PRI:
3x 1.0 mm2
SEC:
2 x 1.0 mm2
Efficency [%]
short circuits to earth (sharp edged metal parts, metal cable clips, louver,
etc.). 85,0
82,5
3.4 Installation instructions
80,0
The switching of LEDs on secondary side is not permitted.
77,5
30 40 50 60 70 80 90 100
3.5 Fixing conditions Load [%]
0,95
>20 mm
Power factor
Leuchte
Luminaire >100 mm >20 mm
0,90
10
0
30 40 50 60 70 80 90 100
Load [%]
Automatic circuit C10 C13 C16 C20 B10 B13 B16 B20 Inrush current
breaker type
Installation Ø 1.5 mm2 1.5 mm2 1.5 mm2 2.5 mm2 1.5 mm2 1.5 mm2 1.5 mm2 2.5 mm2 Imax Time
LCO 100/500/200 fixC L SNC2 7 9 10 14 3 5 7 10 103 A 167 µs
LCO 100/700/143 fixC L SNC2 7 9 10 14 3 5 7 10 103 A 167 µs
LCO 100/1050/95 fixC L SNC2 7 9 10 14 3 5 7 10 103 A 167 µs
LCO 100/1400/71 fixC L SNC2 7 9 10 14 3 5 7 10 103 A 167 µs
This are max. values calculated out of inrush current! Please consider not to exceed the maximum rated continuous current of the circuit breaker.
Calculation uses typical values from ABB series S200 as a reference.
Actual values may differ due to used circuit breaker types and installation environment.
4.3 Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load)
in %
THD 3. 5. 7. 9. 11.
LCO 100/500/200 fixC L SNC2 <9 <5 <5 <5 <3 <2
LCO 100/700/143 fixC L SNC2 <9 <5 <5 <5 <3 <2
LCO 100/1050/95 fixC L SNC2 <9 <5 <5 <5 <3 <2
LCO 100/1400/71 fixC L SNC2 <9 <5 <5 <5 <3 <2
Acc. to 6100-3-2. Harmonics < 5 mA or < 0.6 % (whatever is greater) of the input current are
not considered for calculation of THD.
5. Functions 6. Miscellaneous
5.1 Short-circuit behaviour 6.1 Insulation and electric strength testing of luminaires
In case of a short circuit on the secondary side (LED) the LED Driver switches Electronic devices can be damaged by high voltage. This has to be considered
into hic-cup mode. After the removal of the short-circuit fault the LED Driver will during the routine testing of the luminaires in production.
recover automatically.
According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A,
5.2 No-load operation each luminaire should be submitted to an insulation test with 500 V DC for
1 second. This test voltage should be connected between the interconnected
The LED Driver works in constant voltage mode. In no-load operation the phase and neutral terminals and the earth terminal.
output voltage will not exceed the specified max. output voltage (see page 2). The insulation resistance must be at least 2 MΩ.