Type V Sheet - Light Frame Construction
Type V Sheet - Light Frame Construction
FIN. GRADE
PURLIN BRACING 2 NAT. GRADE OR
MIN.
(2) 2x GIRDER
18"
COMPACTED SOIL
6"
1/2" CLEAR ON FLOOR SEE
#3 DOWELS 24"
18" MIN.
NOTE
30" MAX.
TOP, SIDES GIRDER 4x4 P.T. POST
@24" 12" (7) FOR NAT. GRADE WEEP SCREEDS
12" MIN.
AND END
27" (4)
W/ POST CAP
MIN.
GIRDER SPANS AND HEADER SPANS OR TIE AT INSUL. CONC STEM SHALL BE CORROSION
TABLE R602.7(1) & R602.7(2) GIRDER SPLICES 6" WALL W/ #4 RESISTANT (26 GAGE
12"
GALVANIZED).
27" (4)
SIZE ALLOWABLE SPAN* 3" @ 12" HORZ.
MIN.
3" MIN. MINIMUM 4" ABOVE
EXT- BEARING INT- BEARING CLEAR
BEARING SOIL OR 2" ABOVE
27" (4)
PARTITIONS PARTITIONS POURED CONCRETE
MIN.
2 - #4 BARS TOP PAVED AREAS.
12"
12"
(2) 2X6 6'-0" 6'-1" & BOTTOM, TYP. PIER W/ APPROVED
2. P.T.
(2) 2X8 7'-7" 7'- 9" POST BASE
SILL PLATE
*MAXIMUM TRIBUTARY 2-#4 BARS
NOTES:
FOUND.
WALL
WIDTH = 8' - 0" NOTES: BUILDING SECTION 12" SQ. 12" BOTTOM GABLE END WALL
(1) MINIMUM CONCRETE STRENGTH: 2500 psi.
(1) FLOOR GIRDERS SHALL BE SPACED AT 8' - 0" O.C. MAX.
(2) ANCHOR BOLTS SHALL BE EMBEDDED AT LEAST 7" INTO CONCRETE. FOR TWO-POUR FOUNDATIONS, THE REQUIRED EMBEDMENT SHALL BE PROVIDED IN THE FIRST POUR. ANCHOR BOLTS SHALL BE LOCATED NOT MORE THAN 12",
(2) SILL PLATE SHALL BE PRESERVATIVE - TREATED WHEN LESS THAN 8" FROM
OR LESS THAN 4 - 1/2" FROM SILL PLATE ENDS, CORNERS, AND SPLICES, ANCHOR BOLTS SHALL BE INSTALLED WITH 1/4" X 3" SQUARE PLATE WASHERS.
SOIL.
(3) FASTENERS FOR PRESERVATIVE TREATED WOOD SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER.
(3) SUPPORTING ROOF AND CEILING, MAXIMUM BUILDING WIDTH OF 12 FEET
MEASURED PERPENDICULAR TO THE RIDGE. FOR WIDTHS >12 FEET REFER TO
(4) FOUNDATIONS SHOWN ABOVE ASSUME EXPANSIVE SOILS ARE PRESENT AT THE SITE. FOUNDATION REQUIREMENTS MAY BE REDUCED WHEN JUSTIFIED BY A GEOTECHNICAL REPORT OR APPROVED BY THE BUILDING OFFICIAL.
TABLES IN RESIDENTIAL CODE (5) FRAMING CLIPS SHALL BE 18 GAGE STEEL WITH FOUR 8d NAILS PER LEG (EIGHT 8d NAILS PER CLIP). FRAMING CLIPS SHALL BE ICC APPROVED AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. PAGE
(6) SLAB ON GRADE SHALL BE REINFORCED WITH #3 BARS @ 18" EACH WAY. REINFORCING SHALL BE LOCATED AT SLAB MID-HEIGHT. 1
FLOOR GIRDERS 3 (7) SEE PAGE 3 OF 3, TABLE 150.1A FOR RADIANT BARRIER AND INSULATION REQUIREMENTS BASED ON AHJ'S CLIMATE ZONE OF 3
THIS SHEET IS A SUMMARY OF THE PROVISIONS OF THE 2019 CRC FOR USE WITH SINGLE-STORY CONSTRUCTION
ONLY. DEAD LOAD SHALL NOT EXCEED 15 PSF FOR AVERAGE ROOF AND CEILING, OR EXTERIOR WALLS OR
FLOORS AND PARTITIONS. FLOOR LIVE LOAD SHALL NOT EXCEED 40 PSF. THIS SHEET IS FOR REFERENCE ONLY
AND IS NOT SUBSTITUTE FOR ACCURATE DRAWINGS PREPARED FOR EACH PROPOSED CONSTRUCTION PROJECT.
.
SINGLE STORY CONVENTIONAL WOOD-FRAME CONSTRUCTION SHEET
D MAX.
D/3* 2" D/6 GENERAL NOTES:
MAX. MIN. MAX. (1) SEE FASTENING SCHEDULE (TABLE R602.3(1)) FOR NAILING NOT SHOWN.
(2) BEARING WALLS AND BRACED WALLS REQUIRE CONTINUOUS FOOTINGS. BRACED WALL LINES SHALL
(3) "DF" ON THESE SHEETS REFERS TO DOUGLAS FIR-LARCH. SAWN LUMBER SHALL BE IDENTIFIED BY THE GRADE MARK OF BE PROVIDED AT 25' - 0"
D/3 MAX.
25
AN APPROVED LUMBER GRADING OR INSPECTION AGENCY. X. MAX. IN BOTH DIRECTIONS.
'-
MA
0"
BRACED WALLS OF "
(4) "DL" AND "LL" ON THESE SHEETS INDICATES "DEAD LOAD" AND "LIVE LOAD," RESPECTIVELY -0
M
A
STUCCO SHALL BE FULL 25'
X
4' - 0" MAXIMUM
.
D/4 2" D/6 (5) WOOD MEMBERS SHALL BE OF SUFFICIENT SIZE TO PREVENT SPLITTING DUE TO NAILING. SPLIT MEMBERS SHALL BE
MAX. MIN. MAX. LENGTH. OPENING ARE OFFSET ALONG
REMOVED AND REPLACED. NOT PERMITTED. BRACED WALL LINE.
*NOT PERMITTED AT (6) "P.T." ON THESE SHEETS INDICATES PRESERVATIVE-TREATED WOOD. WALL TYPES SHALL
FLOOR JOISTS (7) WHEN FRAMED WITH ENGINEERED WOOD TRUSSES, ROOF DIAPHRAGMS SHALL BE CONNECTED TO INTERIOR BRACED NOT BE MIXED ALONG
D INTERIOR BRACED
MIDDLE 1/3 SPAN WALLS BY MEANS OF DRAG TRUSSES OR TRUSS BLOCKING. A BRACED WALL LINE.
WALLS SHALL
NO NOTCHES EXTEND TO THE
ROOF.
DF #2 RAFTERS, ALLOWABLE SPANS*
RAFTER DL = 10 PSF, LL = 20 PSF
SPACING 2x4 2x6 2x8 2x10 2x12 L3
RAFTERS, CEILING JOISTS AND FLOOR JOISTS 12" 10' - 10" 16' - 10" 21' - 4" 26' - 0" --
CRC FIG R602.3(1) 16" 9' - 10" 14' - 7" 18' - 5" 22' - 6" 26' - 0" L2
BRACED WALLS SHALL
LW
8' X.
24" 8' - 2" 11' - 11" 15' - 1" 18' - 5" 21' - 4"
-0
* DATA TAKEN FROM TABLE R802.4.1(1) START NO MORE THAN
"
A
8' - 0" FROM THE ENDS L1
OF BRACED WALL LINES.
DF #2 CEILING JOISTS, ALLOWABLE SPANS* MINIMUM LENGTH OF
WALL BRACING = H/2
25% MAX. 40% MAX. ATTICS WITHOUT STORAGE, LL = 10 PSF ATTICS WITH LIMITED STORAGE, LL = 20 PSF
JOIST
SPACING 2x4 2x6 2x8 2x10 2x4 2x6 2x8 2x10
12" 12' - 5" 19' - 6" 25' - 8" -- 9' - 10" 14' - 10" 18' - 9" 22' - 11"
16" 11' - 3" 17' - 8" 23' - 4" -- 8' - 11" 13' - 0" 16' - 6" 20' - 2" BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
5/8" MIN. 5/8" MIN. 24" 9' - 10" 15' - 0" 19' - 1" 23' - 3" 7' - 3" 10' - 8" 13' - 6" 16' - 5"
*DATA FROM CRC TABLE R802.5.1(1) & R802.5.1(2) ATTICS WITH STORAGE ARE THOSE WHERE THE CLEAR
40% MAX. 40% MAX. HEIGHT BETWEEN THE CEILING JOIST AND RAFTER IS 42" OR GREATER. ATTICS SHALL BE UNINHABITABLE. 1
(SEE NOTE 2) CEILING DEAD LOAD SHALL NOT EXCEED 5 PSF.
FIELD NAILING (F.N.)
PANELS SPAN PERPENDICULAR
AT JOISTS/RAFTERS
BEARING PARTITIONS & NON-BEARING RAFTER TIE CONNECTIONS, # 16d COMMON NAILS, SEE NOTE (5)* TO ROOF FRAMING
ALL EXTERIOR WALLS PARTITIONS ROOF PITCH
TIE 3:12 4:12 5:12 7:12 9:12 12:12 STAGGER
CRC FIG R602.6(1) & R602.6(2) JOIST/
SPACING PANELS
SPAN SPAN SPAN SPAN SPAN SPAN 2'-0" MIN. RAFTER
NOTES:
12' 20' 28' 36' 12' 20' 28' 36' 12' 20' 28' 36' 12' 20' 28' 36' 12' 20' 28' 36' 12' 20' 28' 36'
(1) BORED HOLES SHALL NOT BE LOCATED AT THE SAME SECTION SHEATHING
AS A CUT OR NOTCH. 12" 4 6 8 10 3 5 6 8 3 4 5 6 3 4 4 5 3 3 4 4 3 3 3 3 PANEL
(2) BORED HOLES IN BEARING STUDS MAY BE INCREASED TO 60% 16" 5 8 10 13 4 6 8 10 3 5 6 8 3 4 5 6 3 4 4 5 3 3 4 4
IF STUDS ARE DOUBLED; NO MORE THAN TWO SUCCESSIVE 24" 7 11 15 19 5 8 12 15 4 7 9 12 3 5 7 9 3 4 6 7 3 4 4 4
DOUBLE STUDS MAY BE BORED.
*CRC TABLE R802.5.2 VALUES ADJUSTED FOR DF#2 FRAMING. THE NUMBER OF NAILS SPECIFIED IN THE TABLE 2x BLOCKING
AT EXTERIOR
SHALL BE PROVIDED AT EACH CONNECTION. WHEN FULL-HEIGHT INTERIOR BEARING WALLS OR PURLIN BRACING
WALLS
ARE PROVIDED, RAFTER TIE NAILING MAY BE REDUCED PROPORTIONAL TO THE REDUCTION IN RAFTER SPAN; NO
LESS THEN 3 NAILS SHALL BE PROVIDED AT EACH CONNECTION. NO SNOW LOAD
EDGE NAILING (E.N.)
2 AT JOISTS/RAFTERS
BOUNDARY NAILING (B.N.)
AT EXTERIOR WALLS
WHERE PANELS ABUT.
DF #2 FLOOR JOISTS, ALLOWABLE SPANS*
JOIST DL = 10 PSF, LL = 40 PSF PARTIAL ROOF/FLOOR PLAN ROOF/FLOOR SHEATHING
SPACING 2x6 2x8 2x10 2x12
WALL DOUBLE 2x4 @ 16"
STUDS TOP PLATE CRIPPLE STUDS 12" 10' - 9" 14' - 2" 18' - 0" 20' - 11"
16" 9' - 9" 12' - 9" 15' - 7" 18' - 1"
24" 8' - 3" 10' - 5" 12' - 9" 14' - 9" * DATA FROM CRC TABLE R502.3.1(2) EDGE NAILING
(E.N.) DOUBLE
HEADER TOP PLATE
PLYWOOD OR OSB FLOOR AND ROOF SHEATHING, ALLOWABLE SPANS*
15/32"
PROVIDE FULL BEARING SHEATHING GRADES ALLOWABLE LL (psf) ROOF FLOOR STRUCTURAL
AT SUPPORTS PANEL EDGES WITH PANEL
MAX. SPAN (in.) LOADS (psf.)
SPAN RATING SPAN SPAN @ SPAN @ T&G JOINTS OR PARTIAL WALL ELEVATION 2x BLOCKING
WITHOUT
FLOOR/ROOF THICKNESS 16" O.C. 24" O.C. WITH EDGE TOTAL LIVE BLOCKING AT PANEL
DOUBLE TRIMMER WHEN EDGE
SUPPORT LOAD LOAD MAX. SPAN (in.) EDGES
SPAN EXCEEDS 8' - 0" SUPPORT
PANEL NAILING SCHEDULE WALL
24/0 3/8 100 30 24 20 40 30 0 STUDS
24/16 7/16 100 40 24 24 50 40 16 B.N. / E.N. / F.N.
EDGE NAILING FIELD
KING 32/16 15/32, 1/2 180 70 32 28 40 30 16 ROOFS: 8d @ 6" / 6" / 12" (E.N.) AT ALL NAILING
STUD 40/20 19/32, 5/8 305 130 40 32 40 30 20 PANEL EDGES (F.N.)
FLOORS: 8d @ 6" / 6" / 10"
48/24 23/32, 3/4 - 175 48 36 45 35 24
DF#1 HEADER, ALLOWABLE SPANS* WALLS: 8d @ 6" / 12"
* DATA FROM CRC TABLE R503.2.1.1(1) SHEATHING PANELS SHALL BE CONTINUOUS OVER TWO OR MORE SPANS AND EDGE NAILING SILL PLATE
SPAN SIZE PERPENDICULAR TO SUPPORTS. FOR 1/2" SHEATHING MAXIMUM SPAN SHALL BE 24". EDGE SUPPORT MAY BE PROVIDED (E.N.)
UP TO 3' - 6" 4x4 BY TONGUE AND GROOVE EDGES, 2X BLOCKING OR PANEL EDGE CLIPS.
2019 Californania Energy Code Low Rise Residential Buildings Table 150.1-A Component package - Single Family Standard Buildng Design
CLIMATE ZONE
SINLE FAMILY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Below
Roof Deck
(Meets §150.1(c)9A)
Insulation NR NR NR R-19 NR NR NR R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19
, (With Air
1 2
Option B
Space)
Ceiling
R-38 R-38 R-30 R-38 R-30 R-30 R-30 R-38 R-38 R-38 R-38 R-38 R-38 R-38 R-38 R-38
Insulation
Roofs/Celings
Radiant
NR REQ REQ NR REQ REQ REQ NR NR NR NR NR NR NR NR NR
Barrier
(Meets §150.1(c)9A)
Ceiling
R-38 R-30 R-30 R-30 R-30 R-30 R-30 R-30 R-30 R-30 R-38 R-38 R-38 R-38 R-38 R-38
Insulation
Option C
Radiant
NR REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ REQ NR
Barrier
U U U U U U U U U U U U U U U U
Framed 3
0.048 0.048 0.048 0.048 0.048 0.065 0.065 0.048 0.048 0.048 0.048 0.048 0.048 0.048 0.048 0.048
Above Grade
U U U U U U U U U U U U U U U U
Mass Wall
0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.059
Interior 4,5
R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-17
U U U U U U U U U U U U U U U U
Mass Wall
0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.077
Walls
Exterior 6
R-8.0 R-8.0 R-8.0 R-8.0 R-8.0 R-8.0 R-8.0 R-8.0 R-8.0 R-8.0 R-8.0 R-8.0 R-8.0 R-8.0 R-8.0 R-13
Below U U U U U U U U U U U U U U U U
Grade 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.067
Below Grade
Interior R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-13 R-15
BUILDING ENVELOPE
Below U U U U U U U U U U U U U U U U
Grade 0.200 0.200 0.200 0.200 0.200 0.200 0.200 0.200 0.200 0.200 0.200 0.200 0.200 0.100 0.100 0.053
Exterior R-5.0 R-5.0 R-5.0 R-5.0 R-5.0 R-5.0 R-5.0 R-5.0 R-5.0 R-5.0 R-5.0 R-5.0 R-5.0 R-10 R-10 R-19
Slab U 0.58
NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR
Perimeter R-7.0
U U U U U U U U U U U U U U U U
Floors
Raised 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037
R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19
U U U U U U U U U U U U U U U U
Concrete
0.092 0.092 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037
Raised
R-8.0 R-8.0 R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19 R-19
Aged Solar
NR NR NR NR NR NR NR NR NR NR NR NR 0.63 NR 0.63 NR
Reflectance
Sloped
Low-
Roofing Products
Thermal
NR NR NR NR NR NR NR NR NR NR NR NR 0.75 NR 0.75 NR
Resistance
Aged Solar
NR NR NR NR NR NR NR NR NR 0.20 0.20 0.20 0.20 0.20 0.20 NR
Reflectance
sloped
Steep-
Thermal
NR NR NR NR NR NR NR NR NR 0.75 0.75 0.75 0.75 0.75 0.75 NR
Resistance
Maximum U-factor 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30
Fenestration
Maximum SHGC NR 0.23 NR 0.23 NR 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 NR
Maximum Total
20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20%
Area
Maximum West
NR 5% NR 5% NR 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% NR
Facing Area
Door
Maximum U-factor 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20
1 Install the specifed R-value with an airspace present between the roofin and the roof deck, such as standard installation of concrete or clay tile.
2 R-values shown for below roof deck insulation are for wood-frame construction with insulation installed between the framing members. Alternatives including insulation above rafters or above roof deck
shall comply with the performance standards.
3 Assembly U-factors for exterior framed walls can be met with cavity insulaton alone or with continuous insulation alone, or with both cavity and continuous insulation that results in an assembly U-factor
equial to or less than the U-factor shown. Use Referece Joint Appendices JA4 Table 4.3.1,.4.3.1(a), or Table 4.3.4 to determine alternative insulation products to be less than or equal to the required
maximum U-factor.
4 Mass wall has a heat capacity greater han or equal to 7.0 Btu/h-ft2
5 "Interior" denotes insulation installed on the inside surace of the wall. "Exterior" denotes insulation installed on the exterior surface of the wall.
6 Below grade "interior" denotes insulation installed on the inside surface of the wall: and Below grade "exterior" denotes insulation installed on the outside surface of the wall.