Excel For Design 1
Excel For Design 1
WAT
Initial Parameters
ParameterValue Unit Remarks
Inlet Press 565 0C Based on Equipment Catalogue
Inlet Temp 19 Mpa Based on Equipment Catalogue
Condenser 42.6 0C Based on Equipment Catalogue
Extraction Temperatures
ParameterValue Unit Remarks
No. of extr 4 Based on Design Requirements
Tmax 565 0C Inlet Temperature
Tmin 42.6 0C Condenser Temperature
Delta T 104.48 0C (Tmax-Tmin)/(n+1)
Cycle Calculation
State PointTemperatuPressure Enthalpy Entropy Specific V Wpumpin Remarks
1 565 19 3450.287 6.424974 Superheated Vapor
2 460.52 10.5967 3261.998 6.424974 Superheated Vapor
3 565 10.5967 3533.65 6.771491 Superheated Vapor
4 356.04 2.978375 3130.715 6.771491 Superheated Vapor
5 251.56 1.359641 2933.06 6.771491 Superheated Vapor
6 147.08 0.440045 2703.7 6.771491 Superheated Vapor
7 42.6 0.008472 2124.851 6.771491 Wet Mixture
8 42.6 0.008472 178.4014 0.001009 1.363224 Saturated Liquid
9 42.6 0.008472 179.7647 Compressed Liquid
10 147.08 0.440045 619.5914 Compressed Liquid
11 147.08 0.440045 619.5914 Saturated Liquid
12 147.08 0.440045 619.5914 Saturated Liquid
13 193.6771 1.359641 823.8631 0.001147 20.23125 Compressed Liquid
14 193.6771 1.359641 844.0943 Saturated Liquid
15 233.4522 2.978375 1006.45 Compressed Liquid
16 233.4522 2.978375 1006.45 Saturated Liquid
17 233.4522 2.978375 1006.45 Saturated Liquid
18 315.2852 10.5967 1433.538 Compressed Liquid
19 315.2852 10.5967 1433.538 Saturated Liquid
20 315.2852 10.5967 1433.538 Saturated Liquid