DATA SHEET
OF
ProjectProject Unnati
LocatioDahej, Gujarat
This document has been prepared for the above project or named part thereof and should not be relied upon or used for any other project without prior written consent
from IPS-Mehtalia Pvt. Ltd. IPS-Mehtalia Pvt. Ltd. accepts no responsibility or liability for the consequence of this document being used for a purpose other than the
purposes for which it was commissioned. Any person using or relying on the document for such other purpose agrees, and will by such use or Pidlite be taken to confirm
his agreement to indemnify IPS-Mehtalia Pvt. Ltd. for all loss or damage resulting there from. IPS-Mehtalia Pvt. Ltd.accepts no responsibility or liability for this document
to any party other than the person by whom it was commissioned.
COVER PAGE
IPS-MEHTALIA PVT. LTD. Client NSCL
Consulting Engineers . Construction Management . Commissioning & Qualification Project No. MBD21907
B101-109, Kailash Vaibhav Ind. Estate, Vikhroli (W), Mumbai – 400 079 Made/App. NPK/SSP
Document Title Data Sheet of On Off Valve - Flush Bottom (Y Type) Rev A
Document No. IPS-MBD21907-IN-516B Date 16-Aug-2021
DATA SHEET OF ON OFF VALVE - FLUSH BOTTOM (Y TYPE)
Units : Flow :- Liquid: Kg/h Gas: Nm3/h Steam:Kg/h Pressure: bar(g) Temperature:- oC Level/length:- mm
10 End Conn. Flgd. Size & Rating Flanged 150#, ANSI B 16.5, Same as Line Size
BODY 14 Gasket / Packing MOC PTFE / STS, Vendor to Specify suit to Service
23 Construction STS
24 Close At Open At NA NA
Wattage: STS
In Rush Current : STS
SOLENOID Min operating current : STS
VALVE Min. operating voltage : STS
40 Electrical Parameters vender to specify
Plunger drop out : STS
Safety Parameter: STS
Entity
Parameter: STS
45 Model STS
48 Enclosure Protection For Hazardous Area - Intrinsically safe, Ex ia Suitable for Zone-1 , Gr. IIA, IIB, T4/T6
49 Contact Type & Quantity 2 Nos. (1 No. Each for open & close positions)
50 Contact Rating NA
LIMIT SWITCH
51 Cable Entry & Quantity 1/2" NPT (F) & 2 Nos. ( 1 No. Plugged)
52 No.of switches per valve 2 Nos. ( Separate limit switch for valve open & close Indications)
56 ATEX Required.
57 IBR RFS
CERTIFICATION
58 Leak Test Required.
1) NA - Not Applicable
6) Vendor to submit Mat. Test Report, Performance Test Report, Guarantees etc. in triplicate along with delivery.
7) Vendor to submit the instrumet installation manual & G.A. manual in hard copies 3 set soft copies 3 set.
IPS-IN-DOC-03-V1.0 2 of 3 561536167.xlsx
IPS-MEHTALIA PVT. LTD. Client NSCL
Consulting Engineers . Construction Management . Commissioning & Qualification Project No. MBD21907
B101-109, Kailash Vaibhav Ind. Estate, Vikhroli (W), Mumbai – 400 079 Made/App. NPK/SSP
Document Title Data Sheet of On Off Valve - Flush Bottom (Y Type) Rev A
Document No. IPS-MBD21907-IN-516B Date 16-Aug-2021
DATA SHEET OF ON OFF VALVE - FLUSH BOTTOM (Y TYPE)
Operating Temp. Operating Pressure
o
C Kg/cm2 (g) Plug Type-
Instrument P & ID Location / Line Equipment Nature of Fluid Cleatr / Inlet Size Outlet Size Viscosity Density DP Shutoff Fail Safe Gland
Sr. No. TAG No. Instrument Description Rev No. Fluid Leakage Class Vessel Material Body Material Trim Material Seat Material Opening(Inside/Out Port Size Area Classification Remark
Abbreviation No. No. Viscous / Slurry (NB) (NB) CP kg/m3 Kg/cm2 (g) Position Packing
side Vessel)
Min. Nor. Max. Min. Nor. Max.
Legends -
1. FO - Fail to Open
2. FC - Fail to Close
3. FL - Stayput Condition
L - Liquid
V - Vapour
S- Solid
IPS-DOC-IN-03-V1.0 3 of 3 561536167.xlsx