Mechanical Directional Controls
Mechanical Directional Controls
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD1
MECHANICAL DIRECTIONAL CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD2
MECHANICAL DIRECTIONAL CONTROLS
TYPICAL SCHEMATIC
Typical application for the CVA, CVB, CVC, CVR, and CVS is load holding in a lift, check, or dump circuit.
(1) (2)
CVA-CVB-CVC-CVS CVR
(2) (1)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD3
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
#8 SAE, inline check valve.
OPERATION
The IM-CVA allows flow from (2) to (1), while normally blocking oil flow from (1) to (2). The valve has a guided
check ball, which is spring-biased closed until sufficient pressure is applied at (2) to open to (1).
HYDRAULIC SYMBOL
Actual Test Data (Cartridge Only) Nominal Flow 8 GPM (30 LPM)
Rated Operating Pressure 3000 PSI (207 bar)
Typical Internal Leakage
(150 SSU) 0-5 drops/min
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .53 lbs (.24 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD4
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
IM-CVA – –
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD5
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
7 size, 5/8-18 thread, “Mini” series, direct acting check valve.
OPERATION
The MA-CVA allows flow passage from (2) to (1), while normally blocking oil flow from (1) to (2). The cartridge
has a fully guided poppet, which is spring-biased closed, until sufficient pressure is applied at (2) to open to (1).
FEATURES
• Hardened parts for long life and low leakage.
• Optional bias springs for backpressure application flexibility.
• Fully guided poppet.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 5 10 15 20 25 30
300 20
250
Pressure Drop (PSI)
15
200
PERFORMANCE VALVE SPECIFICATIONS
150 10
Actual Test Data (Cartridge Only) Nominal Flow 5 GPM (19 LPM)
100 Rated Operating Pressure 3500 PSI (241 bar)
Flow (LPM) 5 Typical Internal Leakage (150 SSU) 0-5 drops/min
50 0 5 10 15 20 25 30
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
300 20
0 0 Filtration ISO 18/16/13
2500 2 4 6 8 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (PSI)
Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD6
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
MA-CVA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
CRACK RESSURE
0005 5 PSI
0020 20 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD7
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
“High Pressure” 8 size, 3/4-16 thread, “Power” series, direct acting check valve.
OPERATION
The HB-CVA allows free flow passage from (2) to (1), and blocks flow from (1) to (2). The cartridge has a fully
guided check poppet, which is spring-biased closed until sufficient pressure is applied at (2) to open to (1).
FEATURES
• Hardened parts for long life and low leakage.
• Optional bias springs for backpressure application flexibility.
• Fully guided poppet assembly.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 5 10 15 20 25 30 35 40 45
100
PERFORMANCE VALVE SPECIFICATIONS
Pressure Drop (bar) Pressure Drop (bar)
Pressure Drop (PSI)
Actual
75 Test Data (Cartridge Only) 5 Nominal Flow 10 GPM (38 LPM)
Rated Operating Pressure 4350 PSI (300 bar)
Flow (LPM)
50 Typical Internal Leakage (150 SSU) 0-5 drops/min
0 5 10 15 20 25 30 35 40 45
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
100
25 Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (PSI)
75 5
0 0 Weight .10 lbs (.05 kg)
0 2 4 6 8 10 12 Operating Fluid Media General Purpose Hydraulic Fluid
50
Flow (GPM) Cartridge Torque Requirements 35 ft-lbs (47 Nm)
25 Port 2 to 1 Cavity POWER 2W
Cavity Form Tool (Finishing) 40500005
0 0 Seal Kit 21191100
0 2 4 6 8 10 12
Flow (GPM)
Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD8
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
HB-CVA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
CRACK RESSURE
0005 5 PSI
0010 10 PSI
0030 30 PSI
0070 70 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD9
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, direct acting check valve.
OPERATION
The DE-CVA allows free flow passage from (2) to (1), and blocks flow from (1) to (2). The cartridge has a fully
guided check poppet, which is spring-biased closed, until sufficient pressure is applied at (2) to open to (1).
FEATURES
• Hardened parts for long life and low leakage.
• Optional bias springs for backpressure application flexibility.
• Fully guided poppet assembly.
• Industry common cavity.
Flow (LPM)
0 25 50 75
200
Pressure Drop (bar)
150
Pressure Drop (PSI)
10
PERFORMANCE VALVE SPECIFICATIONS
Actual
100 Test Data (Cartridge Only) Nominal Flow 15 GPM (57 LPM)
5 Rated Operating Pressure 3500 PSI (241 bar)
Flow (LPM) Typical Internal Leakage (150 SSU) 0-5 drops/min
50
0 25 50 75
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
200
Filtration ISO 18/16/13
0 0
0 5 10 15 20 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (bar)
150
Pressure Drop (PSI)
Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD10
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-CVA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
S #8 SAE Ports
CRACK RESSURE
0010 10 PSI
0035 35 PSI
0070 70 PSI
0100 100 PSI
0135 135 PSI
0150 150 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD11
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
“High Pressure” 10 size, 7/8-14 thread, “Delta” series, direct acting check valve.
OPERATION
The HE-CVA allows free flow passage from (2) to (1), and blocks flow from (1) to (2). The cartridge has a fully
guided check poppet, which is spring-biased closed, until sufficient pressure is applied at (2) to open to (1).
FEATURES
• Hardened parts for long life and low leakage.
• Optional bias springs for backpressure application flexibility.
• Fully guided poppet assembly.
• Industry common cavity.
Flow (LPM)
0 25 50 75
250
15
200
Pressure Drop (bar)
Pressure Drop (PSI)
Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD12
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
HE-CVA – – –
OPTIONS BODIES
Buna Standard 00 Consult Factory
Viton Standard V0
CRACK RESSURE
0005 5 PSI
0010 10 PSI
0020 20 PSI
0035 35 PSI
0070 70 PSI
0090 90 PSI
0135 135 PSI
0150 150 PSI
± 10% WARNING
DO NOT USE ALUMINUM BODY
HIGH PRESSURE (5000 PSI) PRODUCT
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD13
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
“High Pressure” 12 size, 1 1/16-12 thread, “Tecnord” series, direct acting check valve.
OPERATION
The HT-CVA allows flow passage from (2) to (1), while normally blocking oil flow from (1) to (2). The cartridge
has a fully guided poppet, which is spring biased closed, until sufficient pressure is applied at (2) to open to (1).
FEATURES
• Hardened parts for long life and low leakage.
• Industry common cavity.
• Optional bias springs for backpressure application flexibility.
HYDRAULIC SYMBOL
Flow (LPM)
0 25 50 75 100 125 150
150 10
Pressure Drop (bar)
Pressure Drop (PSI)
100
PERFORMANCE VALVE SPECIFICATIONS
5
Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD14
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
HT-CVA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 S #12 SAE Ports
CRACK RESSURE
0010 10 PSI
0030 30 PSI
0050 50 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD15
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
16 size, 1 5/16-12 thread, “Super” series, direct acting check valve.
OPERATION
The SJ-CVA allows free flow from (2) to (1) and blocks flow from (1) to (2). The cartridge has a fully guided poppet,
which is spring-biased closed, until sufficient pressure is applied at (2) to open to (1).
FEATURES
• Hardened parts for long life and low leakage.
• Industry common cavity.
• Optional bias springs for backpressure application flexibility.
HYDRAULIC SYMBOL
Flow (LPM)
0 25 50 75 100 125 150
150 10
Pressure Drop (bar)
Pressure Drop (PSI)
100
PERFORMANCE VALVE SPECIFICATIONS
5
Actual Test Data (Cartridge Only) Nominal Flow 40 GPM (151 LPM)
50 Rated Operating Pressure 3500 PSI (241 bar)
Flow (LPM)
Typical Internal Leakage (150 SSU) 0-5 drops/min
0 25 50 75 100 125 150
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
1500 0 10
Filtration ISO 18/16/13
0 5 10 15 20 25 30 35 40
Flow (GPM)
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (bar)
Pressure Drop (PSI)
Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD16
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
SJ-CVA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/4” NPTF Ports
S #12 SAE Ports
CRACK RESSURE
0005 5 PSI
0010 10 PSI
0030 30 PSI
0050 50 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD17
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, direct acting, check valve.
OPERATION
The DE-CVB allows free flow passage from (2) to (1), and blocks flow from (1) to (2). The cartridge has a
hardened ball, which is spring-biased closed, until sufficient pressure is applied at (2) to open to (1).
FEATURES
• Hardened seat for long life and low leakage.
• Optional bias springs for backpressure application flexibility.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 5 10 15 20 25 30 35 40 45 50 55
250
15
200
Pressure Drop (bar)
Pressure Drop (PSI)
150 10
100
PERFORMANCE 5 VALVE SPECIFICATIONS
50
Actual Test Data (Cartridge Only) Nominal Flow 10 GPM (38 LPM)
0 0 Rated Operating Pressure 3500 PSI (241 bar)
Flow (LPM)
0 5 10 15 Typical Internal Leakage (150 SSU) 0-5 drops/min
0 5 10 15 20 Flow
25(GPM)
30 35 40 45 50 55
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
250
Port 2 to 1 Filtration ISO 18/16/13
15
200 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (bar)
Pressure Drop (PSI)
Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD18
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-CVB – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
S #8 SAE Ports
CRACK RESSURE
0005 5 PSI
0015 15 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD19
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, direct acting check valve.
OPERATION
The PB-CVC allows free flow passage from (2) to (1), and blocks flow from (1) to (2). The cartridge has a fully
guided hardened ball, which is spring-biased closed, until sufficient pressure is applied at (2) to open to (1).
FEATURES
• Hardened parts for long life and low leakage.
• Optional bias springs for backpressure application flexibility.
• Fully guided ball assembly.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 5 10 15 20 25 30 35 40 45
PERFORMANCE
100 VALVE SPECIFICATIONS
Actual Test Data (Cartridge Only) Nominal Flow 10 GPM (38 LPM)
Pressure Drop (bar)
Pressure Drop (PSI)
Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD20
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
PB-CVC – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
CRACK RESSURE
0005 5 PSI
0020 20 PSI
0030 30 PSI
0050 50 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD21
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, direct acting check valve.
OPERATION
The DE-CVC allows free flow passage from (2) to (1), and blocks flow from (1) to (2). The cartridge has a fully
guided hardened ball, which is spring-biased closed, until sufficient pressure is applied at (2) to open to (1).
FEATURES
• Hardened parts for long life and low leakage.
• Optional bias springs for backpressure application flexibility.
• Fully guided ball assembly.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 10 20 30 40
350
300 20
Pressure Drop (bar)
Pressure Drop (PSI)
250
15
200
150 10
PERFORMANCE VALVE SPECIFICATIONS
100
5
Actual
50 Test Data (Cartridge Only) Nominal Flow 8 GPM (30 LPM)
0 0 Rated Operating Pressure 3500 PSI (241 bar)
0 2 4 Flow
6 (LPM) 8 10 12
Typical Internal Leakage (150 SSU) 0-5 drops/min
Flow (GPM)
0 10 20 30 40 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
350 port 1 to 2
Filtration ISO 18/16/13
300 20 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (bar)
Pressure Drop (PSI)
250
15
Weight .15 lbs (.07 kg)
200
Operating Fluid Media General Purpose Hydraulic Fluid
150 10 Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
100
5
Cavity DELTA 2W
50 Cavity Form Tool (Finishing) 40500000
0 0 Seal Kit 21191200
0 2 4 6 8 10 12
Flow (GPM)
port 1 to 2
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD22
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-CVC – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
S #8 SAE Ports
CRACK RESSURE
0003 3 PSI
0005 5 PSI
0010 10 PSI
0020 20 PSI
0035 35 PSI
0050 50 PSI
0075 75 PSI
0095 95 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD23
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, reverse flow check valve.
OPERATION
The DE-CVR allows free flow (1) to (2) and blocks flow from (2) to (1).
FEATURES
• Hardened parts for long life and low leakage.
• Industry common cavity.
• Optional bias springs for backpressure application flexibility.
HYDRAULIC SYMBOL
Flow (LPM)
0 25 50 75
200
Pressure Drop (bar)
Pressure Drop (PSI)
150 10
PERFORMANCE
100 VALVE SPECIFICATIONS
5
Actual 50
Test Data (Cartridge Only) Nominal Flow 15 GPM (57 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Flow (LPM)
0 0 Typical Internal Leakage (150 SSU) 0-5 drops/min
00 5 25 10 50
15 20 75 25 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
200 Flow (GPM) Filtration ISO 18/16/13
Port 1 to 2 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (bar)
Pressure Drop (PSI)
Port 1 to 2
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD24
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-CVR – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
S #8 SAE Ports
CRACK RESSURE
0005 5 PSI
0025 25 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD25
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
“High Pressure” 12 size, 1 1/16-12 thread, “Tecnord” series, reverse flow check valve.
OPERATION
The HT-CVR allows free flow from (1) to (2) and blocks flow from (2) to (1). The cartridge has a fully guided
poppet, which is spring biased closed, until sufficient pressure is applied at (1) to open to (2).
FEATURES
• Hardened parts for long life and low leakage.
• Industry common cavity.
• Optional bias springs for backpressure application flexibility.
HYDRAULIC SYMBOL
Flow (LPM)
0 25 50 75 100 125 150
150 10
PERFORMANCE VALVE SPECIFICATIONS
Actual Test Data (Cartridge Only) Nominal Flow 35 GPM (132 LPM)
Pressure Drop (bar) Pressure Drop (bar)
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD26
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
HT-CVR – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 S #12 SAE Ports
CRACK RESSURE
0010 10 PSI
0030 30 PSI
0050 50 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD27
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
7 size, 5/8-18 Thread, “Mini” series, direct acting check valve, soft seat, poppet.
OPERATION
The MA-CVS allows free flow (2) to (1) and blocks flow from (1) to (2). The cartridge has a fully guided poppet,
which is spring-biased closed, until sufficient pressure is applied at (2) to open (1).
FEATURES
• Soft seat for ultra low leakage.
• Industry common cavity.
• Optional bias springs for backpressure application flexibility.
• Fully guided poppet.
Flow (LPM)
0 5 10 15 20 25 30
300 20
250
Pressure Drop (bar)
Pressure Drop (PSI)
15
200
PERFORMANCE VALVE SPECIFICATIONS
150 10
Actual Test Data (Cartridge Only) Nominal Flow 2.5 GPM (9.5 LPM)
100
5 Rated Operating Pressure 1500 PSI (103 bar)
Flow (LPM)
50
0 5 10 15 20 25 30
Typical Internal Leakage (150 SSU) Negligible
0
300 0
20 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 2 4 6 8
250 Filtration ISO 18/16/13
Flow (GPM)
Pressure Drop (bar)
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD28
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
MA-CVS – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
CRACK RESSURE
0005 5 PSI
0020 20 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD29
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, direct acting check valve, soft seat, poppet.
OPERATION
The PB-CVS allows free flow passage from (2) to (1), and blocks flow from (1) to (2). The cartridge has a fully
guided poppet, which is spring-biased closed, until sufficient pressure is applied at (2) to open to (1).
FEATURES
• Soft seat for ultra low leakage.
• Optional bias springs for backpressure application flexibility.
• Fully guided poppet assembly.
• Industry common cavity.
Flow (LPM)
0 5 10 15 20 25 30
250
15
200
Pressure Drop (bar)
Pressure Drop (PSI)
150 10
PERFORMANCE VALVE SPECIFICATIONS
100
Actual Test Data (Cartridge Only) Nominal Flow 5 GPM (19 LPM)
5 Rated Operating Pressure 3500 PSI (241 bar)
50 Flow (LPM)
Typical Internal Leakage (150 SSU) Negligible
0 5 10 15 20 25 30
0
250 0 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 2 4 6 8 Filtration ISO 18/16/13
15
200 Flow (GPM) Media Operating Temp. Range -32° to 120°F (0° to 49°C)
Pressure Drop (bar)
Pressure Drop (PSI)
Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD30
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
PB-CVS – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
CRACK RESSURE
0005 5 PSI
0020 20 PSI
0030 30 PSI
0050 50 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD31
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, soft seat check valve.
OPERATION
The DE-CVS allows flow to pass from (2) to (1) and blocks flow from (1) to (2). The cartridge has a fully guided
check poppet, which is spring-biased closed until sufficient pressure is applied at (2) to open to (1).
FEATURES
• Soft seat for ultra low leakage.
• Industry common cavity.
• Optional bias springs for backpressure application flexibility.
Flow (LPM)
0 25 50 75
250
PERFORMANCE 15 VALVE SPECIFICATIONS
200
Pressure Drop (bar)
Pressure Drop (PSI)
Actual Test Data (Cartridge Only) Nominal Flow 10 GPM (38 LTR/N)
150 10 Rated Operating Pressure 1000 PSI (70 bar)
100 Flow (LPM) Typical Internal Leakage (150 SSU) Negligible
0 25 50 755 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
50
250 Filtration ISO 18/16/13
Media Operating Temp. Range -32° to 160°F (0° to 70°C)
0
200 015
Pressure Drop (bar)
0 5 10 15 20
150 Operating Fluid Media General Purpose Hydraulic Fluid
Flow (GPM) 10
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
100 Port 2 to 1 Cavity DELTA 2W
5 Cavity Form Tool (Finishing) 40500000
50
Seal Kit 21191200
0 0
0 5 10 15 20
Flow (GPM)
Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD32
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-CVS – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
S #8 SAE Ports
CRACK RESSURE
0010 10 PSI
± 15%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD33
MECHANICAL DIRECTIONAL CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD34
MECHANICAL DIRECTIONAL CONTROLS
PILOT TO OPEN CHECK VALVES GPM PSI LPM BAR CAVITY MODEL PAGE
DOUBLE PO CHECK VALVES GPM PSI LPM BAR CAVITY MODEL PAGE
PILOT TO CLOSE CHECK VALVES GPM PSI LPM BAR CAVITY MODEL PAGE
LOAD HOLDING VALVES GPM PSI LPM BAR CAVITY MODEL PAGE
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD35
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, pilot operated, ball check valve.
OPERATION
The PP-CPB allows free flow to pass from (2) to (1) and blocks flow from (1) to (2). When pilot pressure is applied
to port (3) the valve allows free flow from (1) to (2).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
For sealed pilot piston consult factory.
Flow (LPM)
0 5 10 15 20
300 20
250
PERFORMANCE VALVE SPECIFICATIONS
Pressure Drop (bar)
Pressure Drop (PSI)
15
200
Actual Test Data (Cartridge Only) Nominal Flow 6 GPM (23 LTR/M) from (1) to (2)
150 10
4 GPM (15 LTR/M) from (2) to (1)
100
Flow (LPM) Rated Operating Pressure 3500 PSI (241 bar)
5
50 Typical Internal Leakage (150 SSU) 0-5 drops/min
0 5 10 15 20
3000 0 Pilot Ratio 4:1
20
0 2 4 6 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
250 Flow (GPM)
Pressure Drop (bar)
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD36
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
PP-CPB – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
CRACK RESSURE
0025 25 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD37
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pilot operated, ball check valve.
OPERATION
The DF-CPB allows free flow to pass from (2) to (1) and blocks flow from (1) to (2). When pilot pressure is applied
to port (3) the valve allows free flow from (1) to (2).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
0 10 20 30 40
300
20
PERFORMANCE VALVE SPECIFICATIONS
250
Actual Test Data (Cartridge Only) Nominal Flow 8 GPM (30 LTR/M) from (1) to (2)
15
Pressure Drop (bar)
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD38
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DF-CPB – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
S #6 SAE Ports
CRACK RESSURE
0025 25 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD39
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pilot to open, ball check valve.
OPERATION
The DF-CPC allows free flow to pass from (2) to (1) and blocks flow from (1) to (2). When pilot pressure is applied
to port (3) the valve allows free flow from (1) to (2). The cartridge has a 2:1 pilot ratio, meaning that at least one
half of the load pressure held at (1) is required at (3) to open the valve. The check is spring biased to assure
holding in static or no-load conditions.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
0 10 20 30 40 50
200
150
Pressure Drop (PSI)
10
Actual Test Data (Cartridge Only) Nominal Flow 10 GPM (38 LPM)
100 Rated Operating Pressure 3500 PSI (241 bar)
Flow (LPM) Typical Internal Leakage (150 SSU) 0-5 drops/min
5
0 10 20 30 40 50 Pilot Ratio 2:1
50
200
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 0 Filtration ISO 18/16/13
Pressure Drop (bar)
150 0
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD40
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DF-CPC – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
CRACK RESSURE
0025 25 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD41
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, double pilot operated check valve.
OPERATION
The PQ-CDP allows flow to pass from (3) to (4) and (2) to (1). The valve blocks flow from (4) to (3) and from (1)
to (2). Blocked flow is released when pilot pressure is applied to the port opposite of (3) and/or (2) respectively.
The valve has a 3:1 pilot ratio, so at least 1/3 of the load pressure at port (4) or (1) is required at the pilot line ports
“ports (4) or (1) respectively” to open the flow passage to allow flow from port (4) or (1) respectively. The check
spring biased at 20 PSI (1.4 bar) to assure holding in the static or no-load conditions.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
150
Pressure Drop (PSI)
Pressure Drop (PSI)
150
9 9
100 100
6 6
50 3 50 3
0 0 0 0
0 1 2 3 4 5 6 0 SPECIFICATIONS
1 2 3 4 5 6
VALVE
Flow (GPM) Flow (GPM)
PRESSURE DROP - PILOTED PRESSURE DROP - PILOTED
Nominal Flow 5 GPM (19 LPM)
Pressure drop 2 Flow
to 1 (LPM)
Pressure drop 3 to 4 Pressure drop 2 to 1
Flow (LPM)
Pressure3000
drop 3PSI
to 4(207 bar)
0 4 8 12 16 20 Rated Operating
0 Pressure
4 8 12 16 20
200 200Internal Leakage (150 SSU)
Typical 0-5 drops/min
PRESSURE DROP - PILOTED
Flow (LPM) 12 Viscosity Range 12647 cSt)
36 to 3000 SSU (3 to
Pressure Drop (bar)
Pressure Drop (bar)
150
Pressure Drop (PSI)
Pressure Drop (PSI)
150
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD42
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
PQ-CDP – – –
OPTIONS BODIES
Urethane Standard U0 Blank Without Body
N 1/4” NPTF Ports
S #6 SAE Ports
SPRING BIAS
0020 20 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD43
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8 -14 thread, “Delta” series, double pilot operated check valve.
OPERATION
The DG-CDP allows flow to pass from (3) to (4) and (2) to (1). The valve blocks flow from (4) to (3) and from (1)
to (2). Blocked flow is released when pilot pressure is applied to the port opposite of (3) and/or (2) respectively.
The valve has a 3:1 pilot ratio, so at least 1/3 of the load pressure at port (4) or (1) is required at the pilot line ports
“ports (4) or (1) respectively” to open the flow passage to allow flow from port (4) or (1) respectively. The check
spring biased at 20 PSI (1.4 bar) to assure holding in the static or no-load conditions.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
12
Pressure Drop (PSI)
150 10
150 10
8
100
100 6
5 4
50
50
2
0 0
0 0
0 2 4 6 8 10
0 2 4 6 8 10 VALVE SPECIFICATIONS
Flow (GPM) Flow (GPM)
Nominal Flow 8 GPM (30 LPM)
Pressure Drop 2 toDROP
PRESSURE 1 Pressure
- PILOTEDDrop 3 to 4 Pressure Drop 4 to 3 Pressure Drop 1 to 2
Rated Operating Pressure 3000 PSI (207 bar)
PRESSURE DROP - PILOTED
Flow (LPM)
Typical Internal Leakage (150Flow
SSU)
(LPM) 0-5 drops/min
0 10
PRESSURE 20- PILOTED
DROP 30
250 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Flow (LPM) 0 10 20 30
15 Filtration
200 ISO 18/16/13
2000 10 20 30
Pressure Drop (bar)
200
Pressure Drop (PSI)
150 10
Weight .20 lbs (.09 kg)
Pressure Drop (bar)
150 12
10
Pressure Drop (bar)
Drop (PSI)
150 8
10 Operating
100 Fluid Media General Purpose Hydraulic Fluid
Pressure
100 8 6
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
100
65 50
Cavity DELTA 4W
4
Pressure
50
4 2
50 Cavity Form Tool (Finishing) 40500002
20 0 0
0
Seal Kit 0 2 4 6 21191216
8 10
0 0 2 4 6 8 100
0 2 4 Flow (GPM)
6 8 10 Flow (GPM)
Pressure DropFlow
2 to 1(GPM)Pressure Drop 3 to 4 Pressure Drop 4 to 3 Pressure Drop 1 to 2
Pressure Drop 4 to 3 Pressure Drop 1 to 2
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD44
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DG-CDP – – –
OPTIONS BODIES
Urethane Standard U0 Blank Without Body
N 1/4” NPTF Ports
S #6 SAE Ports
SPRING BIAS
0020 20 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD45
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pilot to close, ball check valve.
OPERATION
The DF-CPD allows free flow from (3) to (2), and blocks flow from (2) to (3). Flow will be blocked from (3) to (2)
when sufficient pressure is applied at (1). The cartridge has various “pilot ratios” (see options).
Example: 1/4 for 4:1 of the load pressure held at (3) is required at (1) to close the valve. The check is spring
biased to assure holding in static or no-load conditions.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
0 5 10 15 20 25 30 35 40 45
PERFORMANCE
250 VALVE SPECIFICATIONS
15
Actual
200 Test Data (Cartridge Only) Maximum Flow 10 GPM (38 LPM)
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD46
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DF-CPD – – –
OPTIONS BODIES
Buna, 4:1 Ratio 04 Blank Without Body
Buna, 6:1 Ratio 06 N 1/4” NPTF Ports
Viton, 4:1 Ratio V4 S #6 SAE Ports
Viton, 6:1 Ratio V6
CRACK RESSURE
0015 15 PSI
0025 25 PSI
0050 50 PSI
0075 75 PSI
0100 100 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD47
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
16 size, 1 5/16-12 thread, “Super” series, pilot to close, poppet check valve.
OPERATION
The SL-CPD allows free flow from (3) to (2), and blocks flow from (2) to (3). Flow will be blocked from (3) to (2)
when sufficient pressure is applied at (1). The cartridge has a 2:1 pilot ratio, meaning that at least one half of
the load pressure held at (3) is required at (1) to close the valve. The check is spring biased to assure holding in
static or no-load conditions.
FEATURES
• Hardened seat for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Special higher bias spring values available.
Consult factory.
350
150 25 Filtration ISO 18/16/13
(PSI)
10
Pressure Drop (bar)
300
100 20
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
5
50
250 Weight .68 lbs (.31 kg)
0
200 0 15 Operating Fluid Media General Purpose Hydraulic Fluid
1500 5 10 15 20 25 30 35 40 10 Cartridge Torque Requirements 90 ft-lbs (122 Nm)
100 Flow (GPM)
5 Cavity SUPER 3WS
50 Port 3 to 2
Cavity Form Tool (Finishing) 40500021
0 0
0 5 10 15 20 25 30 35 40 Seal Kit 21191404
Flow (GPM)
Port 3 to 2
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD48
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
SL-CPD – – –
OPTIONS BODIES
Buna, 2:1 Ratio 02 Blank Without Body
Viton, 2:1 Ratio V2 S #12 SAE Ports
CRACK RESSURE
0015 15 PSI
0025 25 PSI
0050 50 PSI
0075 75 PSI
0100 100 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD49
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, direct acting check valve with thermal relief.
OPERATION
The DE-CVT allows free flow passage from (2) to (1), and blocks flow from (1) to (2). If the pressure at (1)
exceeds the thermal relief valve setting, a small amount of oil will be allowed to pass from (1) to (2), preventing
cylinder damage from excessive pressure. The cartridge has a fully guided poppet, which is spring biased closed
until sufficient pressure is applied at (2) to open to (1).
Note: the relief valve feature is not intended for use in dynamic pressure limiting applications. Consult factory.
FEATURES
• Hardened parts for long life.
• Optional bias springs for backpressure application flexibility.
• Fully guided poppet assembly.
• Industry common cavity.
Nominal flow rating is 15 GPM for free flow port (2) to (1).
Consult chart for free flow differential pressure.
Thermal relief is cyclic rated to 0.1 GPM. Port (1) to (2)
chart demonstrates override characteristics for a typical
thermal relief application.
Flow (LPM)
Flow (LPM)
0 0 0.5 0.5 1 1 1.5 1.5
35003500
25002500
Pressure Drop (bar)
150
2000 150
2000
1500 100
1500 100
1000
1000 50
500
50
0 500 0 VALVE SPECIFICATIONS
0.0 0 0.1 0.2 0.3 0.4 0.5 0
Flow (GPM)
0.0 0.1 0.2 0.3 0.4 0.5 Nominal Flow 15 GPM (57 LPM)
Port 1 to Flow
2 (GPM)
Rated Operating Pressure 4000 PSI (276 bar)
Port 1 to 2
Flow (LPM ) Typical Internal Leakage (150 SSU) 0-10 drops/min
0 25 50 75
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
125 Flow (LPM )
0 25 50 75 Filtration ISO 18/16/13
100
Pressure Drop (PSI)
125
75 5
100 Weight .31 lbs (.14 kg)
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD50
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-CVT – – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
S #8 SAE Ports
PRESSURE SETTING
1000 PSI 1 VOLTAGE
2000 PSI 2 0020 20 PSI
3000 PSI 3 0100 100 PSI
4000 PSI 4 ± 10%
WARNING
DO NOT USE ALUMINUM BODY
HIGH PRESSURE (4000 PSI) PRODUCT
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD51
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
M20 X 1.5 thread, counterbalance valve, 3:1 ratio.
OPERATION
The QS-CBS check valve allows free flow from the directional valve (2) to the load (1) while a direct-acting, pilot-
assisted relief valve controls flow from port (3) to port (2). Pilot assist at port 1 lowers the effective setting of the
relief valve at a rate determined by the pilot ratio (3:1).
FEATURES
• Hardened parts for long life.
• Industry common metric cavity.
(1)
(3)
Actual Test Data (Cartridge Only) Nominal Flow 15 GPM (57 LPM)
Rated Operating Pressure 4000 PSI (276 bar)
Typical Internal Leakage
(150 SSU) 0-10 drops/min
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .33 lbs (.15 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
Cavity QS SPECIAL 3W
Cavity Form Tool (Finishing) 40500012
Seal Kit 21170016
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD52
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
QS-CBS – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
N 1/2” NPT Ports
PRESSURE RANGE/SETTING
1500 400-1500 PSI
4000 1000-4000 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD53
MECHANICAL DIRECTIONAL CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD54
MECHANICAL DIRECTIONAL CONTROLS
TYPICAL SCHEMATIC
Typical application for MCA, MCB, MCF, MCL, and MCS is an emergency lowering device. Typical application for the MCI is a selector circuit
when load holding is required in both directions. Typical application for the M2G is adjustable speed control or full bypass of fluid motor. Typical
application for the MCP is a pilot dump valve.
(2) (2)
(2) (1)
(1)
(2)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD55
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, manual poppet, 2 way normally closed, pull type valve.
OPERATION
The PB-MCA blocks flow from (1) to (2) until an operator pulls the shaft outward. The bias spring (see option page
for pressure) allows for backpressure at (2) before the valve will open.
Note: pressure at port (2) will act directly on the poppet and spring. Port (2) is intended to be a tank port only.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
• Optional bias springs for backpressure application flexibility.
Flow (LPM)
0 10 20 30 40
80
70 5
Pressure Drop (PSI)
60
Pressure Drop (bar)
4
PERFORMANCE
50 VALVE SPECIFICATIONS
3
40
Actual
30
Test Data (Cartridge Only) Nominal Flow 12 GPM (45 LTR/M)
2
20
Rated Operating Pressure 3500 PSI (241 bar)
Flow (LPM) 1
10 Typical Internal Leakage (150 SSU) 0-5 drops/min
0 10 20 30 40
0 0 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
80
0 2 4 6 8 10 12
5 Filtration ISO 18/16/13
70 Flow (GPM)
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (PSI)
60
Pressure Drop (bar)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD56
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
PB-MCA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPT Ports
Buna, Screen A0 S #6 SAE Ports
Viton, Screen W0
Buna, Knob 0K
Viton, Knob VK
Buna, Knob, Screen AK SPRING BIAS PRESSURE
Viton , Knob, Screen WK 0075 75 PSI
Buna, Detent 0D 0150 150 PSI
Viton, Detent VD
Buna, Screen, Detent AD Note: pressure above SPRING BIAS PRESSURE
Viton, Screen, Detent WD at port (2) may cause valve to self open.
Buna, Knob, Detent 1D
Viton, Knob, Detent 2D
Buna, Knob, Screen, Detent 3D
Viton, Knob, Screen, Detent 4D
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD57
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, manual poppet valve, 2 way normally closed, pull type.
OPERATION
The DE-MCA blocks flow from (1) to (2) until an operator pulls the shaft outward. The bias spring allows for
backpressure at (2) before the valve will open (see option page for pressure).
Note: pressure at port (2) will directly act on the poppet and spring. Port (2) is intended to be a tank port only.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
• Optional bias springs for backpressure application flexibility.
Flow (LPM)
0 25 50 75
125
Pressure Drop (PSI)
100
Pressure Drop (bar)
75 5
PERFORMANCE VALVE SPECIFICATIONS
50
Actual
25 Test Data (Cartridge Only) Nominal Flow 15 GPM (57 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
0 Flow (LPM) 0
00 5 10 15 50 20 Typical Internal Leakage (150 SSU) 5 drops/min
25 75
125 Flow (GPM) Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Port 2 to 1 (valve held open) Filtration ISO 18/16/13
Pressure Drop (PSI)
100
Pressure Drop (bar)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD58
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-MCA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Screen A0 S #8 SAE Ports
Viton, Screen W0
Buna, Knob 0K
Viton, Knob VK
Buna, Knob, Screen AK SPRING BIAS PRESSURE
Viton, Knob, Screen WK 0065 65 PSI
0160 160 PSI
Note: use screen only if flow direction
is from (1) to (2). Note: pressure above SPRING BIAS PRESSURE
at port (2) may cause valve to self open.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD59
MECHANICAL DIRECTIONAL CONTROLS
DE-MCF MANUAL POPPET VALVE, 2 WAY NORMALLY CLOSED, PULL TYPE, SOFT SEAT
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, manual poppet valve, 2 way normally closed, pull type, soft seat.
OPERATION
The DE-MCF blocks flow from (1) to (2) until an operator pulls the shaft outward. The bias spring allows for
backpressure at (2) before the valve will open (see option page for pressure).
Note: pressure at port (2) will directly act on the spool and spring. Port (2) is intended to be a tank port only.
FEATURES
• Soft seat for ultra low leakage.
• Industry common cavity.
HYDRAULIC SYMBOL
Pressure above SPRING BIAS PRESSURE at port
(2) may cause valve to self open.
Flow (LPM)
0 25 50 75
125
100
Pressure Drop (PSI)
75 5
PERFORMANCE VALVE SPECIFICATIONS
50
100
Pressure Drop (bar)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD60
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-MCF – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Screen A0 S #8 SAE Ports
Viton, Screen W0
Buna, Knob 0K
Viton, Knob VK
Buna, Knob, Screen AK SPRING BIAS PRESSURE
Viton, Knob, Screen WK 0065 65 PSI
Note: use screen only if flow direction Note: pressure above SPRING BIAS PRESSURE
is from (1) to (2). at port (2) may cause valve to self open.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD61
MECHANICAL DIRECTIONAL CONTROLS
DE-MCS MANUAL POPPET VALVE, 2 WAY NORMALLY CLOSED, PULL TYPE, CORROSION RESISTANT
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, manual poppet valve, 2 way normally closed, pull type, corrosion resistant.
OPERATION
The DE-MCS blocks flow from (1) to (2) until an operator pulls the shaft outward. The bias spring allows for
backpressure at (2) before the valve will open (see option page for pressure).
Note: pressure at port (2) will directly act on the spool and spring. Port (2) is intended to be a tank port only.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
• Corrosion resistant.
• Optional bias springs for backpressure application flexibility.
Flow (LPM)
75 0 25 50 5 75 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
125 Filtration ISO 18/16/13
50
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
100
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD62
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-MCS – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Screen A0 S #8 SAE Ports
Viton, Screen W0
Buna, Knob 0K
Viton, Knob VK
Buna, Knob, Screen AK SPRING BIAS PRESSURE
Viton, Knob, Screen WK 0065 65 PSI
0160 160 PSI
Note: use screen only if flow direction
is from (1) to (2). Note: pressure above SPRING BIAS PRESSURE
at port (2) may cause valve to self open.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD63
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, manual poppet valve, 2 way normally closed, pull with detent.
OPERATION
The DE-MCB blocks flow from (1) to (2) until an operator pulls the shaft outward. The bias spring allows for
backpressure at (2) before the valve will open (see option page for pressure).
Note: pressure at port (2) will directly act on the spool and spring. Port (2) is intended to be a tank port only.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
• Optional bias springs for backpressure application flexibility.
Flow (LPM)
0 25 50 75
125
PERFORMANCE
100 VALVE SPECIFICATIONS
Pressure Drop (PSI)
Actual
75 Test Data (Cartridge Only) 5 Nominal Flow 20 GPM (76 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
50 Flow (LPM)
Typical Internal Leakage (150 SSU) 5 drops/min
0 25 50 75
25
125 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 0
Filtration ISO 18/16/13
1000 5 10 15 20 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD64
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-MCB – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Screen A0 S #8 SAE Ports
Viton, Screen W0
Buna, Knob 0K
Viton, Knob VK
Buna, Knob, Screen AK SPRING BIAS PRESSURE
Viton, Knob, Screen WK 0065 65 PSI
0160 160 PSI
Note: use screen only if flow direction
is from (1) to (2). Note: pressure above SPRING BIAS PRESSURE
at port (2) may cause valve to self open.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD65
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, manual poppet, 2 way normally closed, push type valve.
OPERATION
The PB-MCI blocks flow from (2) to (1) until sufficient force is applied to button to overcome spring bias and load
force.
Actuation Force Required
No Pressure 7 lbs
Side Pressure 7 + (P1 x .009)
Nose Pressure 7 + (P1 x .076)
Note: (Ø .437) cavity predrill depth must be 1.312 minimum from spotface.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 5 10 15 20 25 30 35
200
PERFORMANCE VALVE SPECIFICATIONS
Pressure Drop (PSI)
150 10
Actual Test Data (Cartridge Only) Nominal Flow 8 GPM (30 LPM)
100 Rated Operating Pressure 3500 PSI (241 bar)
5 Typical Internal Leakage (150 SSU) Consult Factory
50 Flow (LPM)
0 5 10 15 20 25 30 35 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
200
0 0 Filtration ISO 18/16/13
0 2 4 6 8 10
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (PSI)
Flow (GPM)
150 10
Port 2 to 1 (lever held open)
Weight .26 lbs (.12 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
100
Cartridge Torque Requirements 25 ft-lbs (34 Nm)
5
50 Cavity POWER 2W
Cavity Form Tool (Finishing) 40500005
0 0 Seal Kit 21191102
0 2 4 6 8 10
Flow (GPM)
Port 2 to 1 (lever held open)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD66
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
PB-MCI – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Screen A0 S #6 SAE Ports
Viton, Screen W0
Buna, Lever 0L
Viton, Lever VL
Buna, Screen, Lever AL
Viton, Screen, Lever WL
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD67
MECHANICAL DIRECTIONAL CONTROLS
PB-MCL MANUAL POPPET VALVE, 2 WAY NORMALLY CLOSED, PULL TYPE, LEVER
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, manual poppet, 2 way normally closed, pull type valve with lever.
OPERATION
The PB-MCL blocks flow from (1) to (2) until an operator pulls the handle upward. The bias spring (see option
page for pressure) allows for backpressure at (2) before the valve will open.
Note: Pressure at port (2) will directly act on the spool and spring. Port (2) is intended to be a tank port only.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Pressure above SPRING BIAS PRESSURE at port
(2) may cause valve to self open.
Flow (LPM)
0 5 10 15 20 25 30
80
70 5
PERFORMANCE VALVE SPECIFICATIONS
Pressure Drop (PSI)
60
Pressure Drop (bar)
4
50
Actual Test Data (Cartridge Only) 3
Nominal Flow 8 GPM (30 LTR/M)
40
Rated Operating Pressure 3500 PSI (241 bar)
30 Flow (LPM) 2
Typical Internal Leakage (150 SSU) 0-5 drops/min
20 0 5 10 15 20 25 30
1 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
10 80
5 Filtration ISO 18/16/13
0 70 0
060 2 4 6 8 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (PSI)
4
Flow (GPM) Weight .33 lbs (.15 kg)
50
Port 2 to 1 (detent open) 3 Operating Fluid Media General Purpose Hydraulic Fluid
40
Cartridge Torque Requirements 25 ft-lbs (34 Nm)
30 2
Cavity POWER 2W
20
1 Cavity Form Tool (Finishing) 40500005
10
Seal Kit 21191101
0 0
0 2 4 6 8
Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD68
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
PB-MCL – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPT Ports
Buna, Screen A0 S #6 SAE Ports
Viton, Screen W0
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD69
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, normally closed, manual pull valve.
OPERATION
The DE-MCL blocks flow from (1) to (2) until an operator pulls the shaft outward. The bias spring allows for
backpressure at (2) before the valve will open (see option page for pressure).
Note: pressure at port (2) will directly act on the spool and spring. Port (2) is intended to be a tank port only. The
cartridge offers smooth transition in response to load changes in common hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Pressure above SPRING BIAS PRESSURE at port
(2) may cause valve to self open.
Flow (LPM)
0 5 10 15 20 25 30 35 40 45 50 55
150 10
100
Actual Test Data (Cartridge Only) Nominal Flow 15 GPM (57 LPM)
5
Rated Operating Pressure 3500 PSI (241 bar)
50 Flow (LPM) Typical Internal Leakage (150 SSU) 5 drops/min (82 ml/min)
0 5 10 15 20 25 30 35 40 45 50 55 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
150 10 Filtration ISO 18/16/13
0 0
0 5 10 15 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD70
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-MCL – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Screen A0 S #8 SAE Ports
Viton, Screen W0
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD71
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, manual rotary spool valve, 2 way normally closed.
OPERATION
The DE-M2G when rotated clockwise (fully closed position) blocks flow from (1) to (2) and (2) to (1). When rotated
counterclockwise (fully open position), the cartridge allows flow from (1) to (2) and (2) to (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
0 25 50 75
100
Pressure Drop (PSI)
75 5
PERFORMANCE VALVE SPECIFICATIONS
50
Actual Test Data (Cartridge Only) Nominal Flow 20 GPM (76 LPM)
Rated Operating Pressure 3000 PSI (207 bar)
25
Flow (LPM)
Typical Internal Leakage (150 SSU) 5 cu/in per min (82 ml/min)
0 25 50 75 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 0
1000 5 10 15 20
Filtration ISO 18/16/13
Flow (GPM) Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .27 lbs (.12 kg)
Pressure Drop (PSI)
75 Port 1 to 2 5
Operating Fluid Media General Purpose Hydraulic Fluid
50 Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
Cavity DELTA 2W
25 Cavity Form Tool (Finishing) 40500000
Seal Kit 21191202
0 0
0 5 10 15 20
Flow (GPM)
Port 1 to 2
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD72
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-M2G – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Screen A0 S #8 SAE Ports
Viton, Screen W0
Buna, Knob 0K
Viton, Knob VK
Buna, Knob, Screen AK
Viton, Knob, Screen WK
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD73
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, manual valve, 2 way normally closed, push type.
OPERATION
The HB-MCP blocks flow from (2) to (1) until an operator pushes the knob in allowing pressure at port #2 to
drop to port #1 pressure.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Good as a pilot dump valve. Port #1 should be
limited to <500 PSI to allow actuation (50 lbs),
Port #2 actuation load at 4000 PSI (50 lbs).
Flow (LPM)
0 1 2 3
4000
3500 250
3000
Pressure Drop (bar)
200
2500
Actual Test Data (Cartridge Only) 150 Nominal Flow 1 GPM (4 LPM)
2000
Max. Operating Pressure 4000 PSI (276 bar)
1500 Flow (LPM) 100
1000
Typical Internal Leakage (150 SSU) 5 drops/min
0 1 2 3 50
500 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
4000
0 0 250 Filtration ISO 18/16/13
3500 0 0.2 0.4 0.6 0.8 1
Media Operating Temp. Range 32° to 160°F (0° to 70°C)
Pressure Dro p (PSI)
3000
Pressure Drop (bar)
- Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD74
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
HB-MCP – –
OPTIONS BODIES
Buna, Knob 0K Blank Without Body
Viton, Knob VK N 1/4” NPTF Ports
S #6 SAE Ports
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD75
MECHANICAL DIRECTIONAL CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD76
MECHANICAL DIRECTIONAL CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD77
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, 4 way piloted directional valve.
OPERATION
The HG-PDA in neutral (un-piloted), allows flow between (2) and (1) bi-directionally, while blocking at (3). The
spring chamber is constantly vented at (1). On attainment of a predetermined pressure at (4), the cartridge
redirects flow from (2) to (1), to (2) to (3).
1
Note: that the backpressure value at (1) must be added to the selected pressure setting to determine pilot
pressure necessary to shift valve to second position.
2
FEATURES
• Hardened parts for long life.
3 • Industry common cavity
1
HYDRAULIC SYMBOL
3 .030 to .060 diameter orifice recommended
beneath port (4).
Flow (LPM)
PERFORMANCE 0 10 20 30 40 VALVE SPECIFICATIONS
Actual Test200
Data (Cartridge Only) Nominal Flow 10 GPM (38 LTR/M)
Rated Operating Pressure 4000 PSI (276 bar)
Pressure Drop (BAR)
Pressure Drop (PSI)
150 Flow (LPM) Typical Internal Leakage (150 SSU) 8 cu in/min (82 ml/min)
10
0 10 20 30 40 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
200 Filtration ISO 18/16/13
100
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (BAR)
Weight 5
Pressure Drop (PSI)
Port 2 to 3 Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD78
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
.81
[20.6]
1.50
[38.1]
1.00 HEX
[25.4]
1.25
[31.8]
.72
.75 [18.3]
[19.1]
.63
[15.9]
1.38
[34.9]
2.00
[50.8]
2.88
7/8-14 UNF - 2A 3.25 [73.2]
2.46 [82.6]
[62.4]
#6 SAE PORTS
4X
Ø.28
[7.1]
.13 2.25 MTG. HOLES
[3.3] [57.1] 2X
2.50
[63.5]
Body Weight: .99 lbs (.45 kg)
ORDERING INFORMATION
HG-PDA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
PRESSURE SETTINGS
0040 40 PSI
0080 80 PSI
0160 160 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD79
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, 2 way normally closed piloted directional valve.
OPERATION
The HG-PDC in neutral (unpiloted), blocks flow between (2) and (3). The spring chamber is constantly vented at
(1). On attainment of a predetermined pressure at (4), the cartridge allows flow from (2) to (3).
1 Note: that the backpressure value at (1) must be added to the selected pressure setting to determine pilot
pressure necessary to shift valve to second position.
FEATURES
1 2 • Hardened parts for long life.
• Industry common cavity
2 3
HYDRAULIC SYMBOL
.030 to .060 diameter orifice recommended
beneath port (4).
Actual Test Data (Cartridge Only) Nominal Flow 10 GPM (38 LPM)
Rated Operating Pressure 4000 PSI (276 bar)
Flow (LPM)
Flow (LPM) Typical Internal Leakage (150 SSU) 8 cu in/min (82 ml/min)
00 10 10 20 20 30 30 40 40
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
200
200 Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (BAR)
150
150 10 Weight .63 lbs (.28 kg)
10
Operating Fluid Media General Purpose Hydraulic Fluid
Cavity
5 Form Tool (Finishing) 40500002
50
Seal Kit 21191214
50
0 0
00 2 4 6 8 10 12 0
0 2 Flow
4 (GPM)6 8 10 12
Port 2Flow
to 3 (GPM)
Port 2 to 3
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD80
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
.81
[20.6]
1.50
[38.1]
1.00 HEX
[25.4]
1.25
[31.8]
.72
.75 [18.3]
[19.1]
.63
[15.9]
1.38
[34.9]
2.00
[50.8]
2.88
7/8-14 UNF - 2A 3.25 [73.2]
2.46 [82.6]
[62.4]
#6 SAE PORTS
4X
Ø.28
[7.1]
.13 2.25 MTG. HOLES
[3.3] [57.1] 2X
2.50
[63.5]
Body Weight: .99 lbs (.45 kg)
ORDERING INFORMATION
HG-PDC – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
PRESSURE SETTINGS
0040 40 PSI
0080 80 PSI
0160 160 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD81
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, 3 way normally open piloted directional valve.
OPERATION
The HG-PDI in neutral (un-piloted), allows flow between (3) and (2) bi-directional, while blocking at (4). The spring
chamber is constantly vented at (1). On attainment of a predetermined pressure at (4), the cartridge shifts to close
(3) to (2), while opening (4) to (3).
1
Note: that the backpressure value at (1) must be added to the selected pressure setting to determine pilot
pressure necessary to shift valve to second position.
2
FEATURES
• Hardened parts for long life.
3 • Industry common cavity
HYDRAULIC SYMBOL
Actual Test Data (Cartridge Only) Nominal Flow 10 GPM (38 LPM)
Rated Operating Pressure 3000 PSI (207 bar)
Flow Flow
(LPM)(LPM) Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)
00 5 10 10 15 20 20
25 30 30
35 40 45 40 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
200
2000
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (BAR)
1500
Drop(PSI)
Cavity DELTA 4W
50
Pressure
Cavity
5 Form Tool (Finishing) 40500002
500
Seal Kit 21191214
50
0 0
0 2 4 6 8 10 12
0 0
Flow (GPM)
0 2 4 6 8 10 12
Port 4 to 3 Port 2 to 3
Flow (GPM)
Port 2 to 3
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD82
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
.81
[20.6]
1.50
[38.1]
1.00 HEX
[25.4]
1.25
[31.8]
.72
.75 [18.3]
[19.1]
.63
[15.9]
1.38
[34.9]
2.00
[50.8]
2.88
7/8-14 UNF - 2A 3.25 [73.2]
2.46 [82.6]
[62.4]
#6 SAE PORTS
4X
Ø.28
[7.1]
.13 2.25 MTG. HOLES
[3.3] [57.1] 2X
2.50
[63.5]
Body Weight: .99 lbs (.45 kg)
ORDERING INFORMATION
HG-PDI – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
PRESSURE SETTINGS
0055 55 PSI
0080 80 PSI
0160 160 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD83
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, 2 way normally open piloted directional valve.
OPERATION
The HG-PDO in neutral (un-piloted), allows flow between (2) and (3) bi-directionally.
The spring chamber is constantly vented at (1). On attainment of a predetermined pressure at (4), the cartridge
blocks flow from (2) to (3).
1
Note: that the backpressure value at (1) must be added to the selected pressure setting to determine pilot
pressure necessary to shift valve to second position.
2
FEATURES
• Hardened parts for long life.
3 • Industry common cavity
HYDRAULIC SYMBOL
.030 to .060 diameter orifice recommended
beneath port (4).
Flow (LPM)
PERFORMANCE 0 10 20 30 40 VALVE SPECIFICATIONS
Actual Test200
Data (Cartridge Only) Nominal Flow 10 GPM (38 LTR/M)
Rated Operating Pressure 4000 PSI (276 bar)
Pressure Drop (BAR)
Flow (LPM)
Pressure Drop (PSI)
Port 2 to 3
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD84
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
.81
[20.6]
1.50
[38.1]
1.00 HEX
[25.4]
1.25
[31.8]
.72
.75 [18.3]
[19.1]
.63
[15.9]
1.38
[34.9]
2.00
[50.8]
2.88
7/8-14 UNF - 2A 3.25 [73.2]
2.46 [82.6]
[62.4]
#6 SAE PORTS
4X
Ø.28
[7.1]
.13 2.25 MTG. HOLES
[3.3] [57.1] 2X
2.50
[63.5]
Body Weight: .99 lbs (.45 kg)
ORDERING INFORMATION
HG-PDO – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
PRESSURE SETTINGS
0040 40 PSI
0080 80 PSI
0160 160 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD85
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, external pilot normally closed, piloted directional valve.
OPERATION
The HF-PDE blocks flow at ports (2) and (1). On attainment of a predetermined pressure at (3) the valve shifts
to a allow flow from (1) to (2).
FEATURES
1 • Hardened parts for long life.
• Industry common cavity
2
1
2 3
3
HYDRAULIC SYMBOL
.030 to .060 diameter orifice recommended
beneath port (3).
Actual Test Data (Cartridge Only) Nominal Flow 10 GPM (38 LPM)
Flow (LPM)
Rated Operating Pressure 4000 PSI (276 bar)
0 5 10 15 20 25 30 35 40 45 50
Flow (LPM) Typical Internal Leakage (150 SSU) 8 cu in/min (82 ml/min)
200
0 5 10 15 20 25 30 35 40 45 50 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
200 Filtration ISO 18/16/13
Pressure Drop (BAR)
Pressure Drop (PSI)
150 10 Range
Media Operating Temp. -40° to 250°F (-40° to 120°C)
Pressure Drop (BAR)
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD86
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
.75
[19.0]
1.50
[38.1]
1.00 HEX
[25.4]
1.25
[31.8]
#6 SAE PORTS
.75 .72
3X
[18.3]
[19.0]
.62
[15.9]
1.38
[34.8]
2.13
7/8-14 [53.8]
1.84 UNF - 2A
[46.7] 2.50
[63.5]
ORDERING INFORMATION
HF-PDE – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
PRESSURE SETTINGS
0050 50 PSI
0095 95 PSI
0165 165 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD87
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, internal pilot and drain, piloted directional valve.
OPERATION
The HF-PDI blocks flow at (3) and allows flow from (2) to (1). On attainment of a predetermined pressure at (3)
the valve shifts to a allow flow from (3) to (2) and block flow at (1).
FEATURES
1 • Hardened parts for long life.
• Industry common cavity
HYDRAULIC SYMBOL
Actual Test Data (Cartridge Only) Nominal Flow 10 GPM (38 LPM)
Flow (LPM)
Rated Operating Pressure 3000 PSI (207 bar)
0 Flow
5 (LPM)
10 15 20 25 30 35 40 45 50
Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)
0 10200 20 30 40
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
2000
Filtration ISO 18/16/13
Pressure Drop (BAR)
Pressure Drop (PSI)
150 10 Range
Media Operating Temp. -40° to 250°F (-40° to 120°C)
Pressure Drop (BAR)
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD88
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
.75
[19.0]
1.50
[38.1]
1.00 HEX
[25.4]
1.25
[31.8]
#6 SAE PORTS
.75 .72
3X
[18.3]
[19.0]
.62
[15.9]
1.38
[34.8]
2.13
7/8-14 [53.8]
1.84 UNF - 2A
[46.7] 2.50
[63.5]
ORDERING INFORMATION
HF-PDI – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
PRESSURE SETTINGS
0050 50 PSI
00100 100 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD89
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
16 size, 1 5/16 -12 thread, “Super” series, pilot to shift, 3 way valve, open transition.
OPERATION
In neutral the SO-PTS allows flow between ports (3) and (4), port (2) is blocked. With application of a remote
pilot signal at (5), the valve’s spool shifts to allow flow between ports (2) and (3), while port (4) is blocked. During
transition ports (2), (3), and (4) are open The spring chamber is vented to the tank through port (1). The vented
spring chamber allows the valve to be fully pressurized at ports (2), (3), and (4) without affecting required pilot
pressure. Pressure at (1) will affect required pilot pressure.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
0 25 50 75 100 125 150
PERFORMANCE
200
VALVE SPECIFICATIONS
Actual Test Data (Cartridge Only) Nominal Flow 40 GPM (151 LTR/M)
Pressure Drop (BAR)
Pressure Drop (PSI)
150 10
Weight 1.11 lbs (.50 kg)
0 0 Operating Fluid Media General Purpose Hydraulic Fluid
100
0 5 10 15 20 25 30 35 40
Cartridge Torque Requirements 90 ft-lbs (122 Nm)
Flow (GPM) 5
Cavity SUPER 5W SHORT
50 Port 3 to 4 Port 3 to 2
Cavity Form Tool (Finishing) 40500020
Seal Kit 21191410
0 0
0 5 10 15 20 25 30 35 40
Flow (GPM)
Port 3 to 4 Port 3 to 2
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD90
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
SO-PTS – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 S #12 SAE Ports
SPRING BIAS
0070 70 PSI
0150 150 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD91
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
16 size, 1 5/16 -12 thread, “Super” series, pilot to shift, 3 way valve, closed transition.
OPERATION
In neutral the SO-PTT allows flow between ports (3) and (4), port (2) is blocked. With application of a remote
pilot signal at (5), the valve’s spool shifts to allow flow between ports (2) and (3), while port (4) is blocked. During
transition all ports are closed. The spring chamber is vented to the tank through port (1). The vented spring
chamber allows the valve to be fully pressurized at ports (2), (3), and (4) without affecting required pilot pressure.
Pressure at (1) will affect required pilot pressure.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
0 25 50 75 100 125 150
150
PERFORMANCE 10 VALVE SPECIFICATIONS
Actual Test Data (Cartridge Only) Nominal Flow 40 GPM (151 LTR/M)
Pressure Drop (PSI)
100
Rated Operating Pressure 3500 PSI (241 bar)
5 Typical Internal Leakage (150 SSU) 10 cu in/min (164 ml/min)
Flow (LPM)
50 0 25 50 75 100 125 150 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
150 10 Filtration ISO 18/16/13
0 0 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (PSI)
0 5 10 15 20 25 30 35 40
100 Weight 1.08 lbs (.49 kg)
Flow (GPM)
5 Operating Fluid Media General Purpose Hydraulic Fluid
Port 3 to 4 Port 3 to 2
50 Cartridge Torque Requirements 90 ft-lbs (122 Nm)
Cavity SUPER 5W SHORT
Cavity Form Tool (Finishing) 40500020
0 0
0 5 10 15 20 25 30 35 40 Seal Kit 21191410
Flow (GPM)
Port 3 to 4 Port 3 to 2
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD92
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
SO-PTT – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 S #12 SAE Ports
SPRING BIAS
0070 70 PSI
0150 150 PSI
± 10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD93
MECHANICAL DIRECTIONAL CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD94
MECHANICAL DIRECTIONAL CONTROLS
SHUTTLE VALVES
TYPICAL SCHEMATIC
Typical application for the CSB is to provide load sense to a pressure compensator valve.
(1)
(2)
CSB
(3)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD95
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
#6 SAE, inline shuttle valve.
OPERATION
The IM-CSB allows flow from the higher pressure of (1) or (3) to (2). The valve is commonly
used as a load sense to direct oil from the pressure side of a bidirectional hydraulic motor
to a pressure released hydraulic brake.
FEATURES
• Hardened parts for long life.
HYDRAULIC SYMBOL
Actual Test Data (Cartridge Only) Nominal Flow Max 10 GPM (38 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Typical Internal Leakage
(150 SSU) 1 cu in/min (16 ml/min)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .28 lbs (.13 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD96
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
IM-CSB –
OPTIONS
Buna Standard 00
Viton Standard V0
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD97
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, shuttle valve.
OPERATION
The PP-CSB allows flow from the higher pressure of (1) or (3) to (2). The valve is commonly used as a load sense
to direct oil from the pressure side of a bidirectional hydraulic motor to a pressure released hydraulic brake.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
PERFORMANCE
0 5 10 15 20 25 30 VALVE SPECIFICATIONS
200
Actual Test Data (Cartridge Only) Nominal Flow 6 GPM (23 LTR/M)
Rated Operating Pressure 3500 PSI (241 bar)
150
Pressure Drop (PSI)
10
Pressure Drop (bar)
Flow (LPM) Typical Internal Leakage (150 SSU) 1 cu in/min (16 ml/min)
0 5 10 15 20 25 30 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
100
200 Filtration ISO 18/16/13
5 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
50
150
Pressure Drop (PSI)
Port 1 to 2 Port 3 to 2
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD98
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
PP-CSB – –
OPTIONS BODIES
Buna, Standard 00 Blank Without Body
Viton, Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD99
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, shuttle valve.
OPERATION
The DF-CSB allows flow from the higher pressure of (1) or (3) to (2). The valve is commonly used as a load sense
to direct oil from the pressure side of a bidirectional hydraulic motor to a pressure-released hydraulic brake.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
PERFORMANCE 0 10 20 30 40 VALVE SPECIFICATIONS
200
Actual Test Data (Cartridge Only) Nominal Flow 8 GPM (30 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD100
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DF-CSB – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD101
MECHANICAL DIRECTIONAL CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD102
MECHANICAL DIRECTIONAL CONTROLS
ROTARY VALVES
(A)(C)(E)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD103
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
16 size, 1 5/16-12, “Super” series, manual rotary spool valve.
OPERATION
The SJ-MRA regulates flow from (1) to (2) or (2) to (1). Counter-clockwise Rotation of 90° adjusts valve from fully
closed to fully open.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 25 50 75 100 125 150
200
150
Pressure Drop (PSI)
10
Pressure Drop (bar)
Port 1 to 2 (valve fully open) Operating Fluid Media General Purpose Hydraulic Fluid
100 Cartridge Torque Requirements 90 ft-lbs (122 Nm)
5 Cavity SUPER 2W
50 Cavity Form Tool (Finishing) 40500017
Seal Kit 21191402
0 0
0 5 10 15 20 25 30 35 40
Flow (GPM)
Port 1 to 2 (valve fully open)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD104
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
SJ-MRA – –
OPTIONS BODIES
Buna, Standard 00 Blank Without Body
Viton, Standard V0 N 3/4” NPTF Ports
S #12 SAE Ports
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD105
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, 3 way 2 position, manual rotary spool valve.
OPERATION
The DF-M3A when rotated fully to the clockwise position, the cartridge directs flow from (3) to (2) or (2) to (3) and
blocks flow at (1). When rotated fully to the counterclockwise position, the cartridge directs flow from (1) to (3) or
(3) to (1) and blocks flow at (2). All ports are closed in transition.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
10 15 20 25 30 35 40 45
10
PERFORMANCE VALVE SPECIFICATIONS
Pressure Drop (bar)
Actual Test Data (Cartridge Only) Nominal Flow 12 GPM (45 LPM)
Rated Operating Pressure 3000 PSI (207 bar)
Flow (LPM) Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)
5
0 5 10 15 20 25 30 35 40 45 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
150 10 Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (PSI)
Port 1 to 3 Port 2 to 3
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD106
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DF-M3A – –
OPTIONS BODIES
Buna, Standard 00 Blank Without Body
Viton, Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD107
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, manual rotary spool valve, 4 way 2 position, criss cross.
OPERATION
The DG-M4A, when rotated fully to clockwise position, the cartridge directs flow between (2) to (3) and (1) to (4).
When rotated fully to counterclockwise position, the cartridge directs flow between (3) to (4) and (1) to (2). All
ports are closed in transition.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
0 10 20 30 40
200
Pressure Drop (PSI)
150 10
Flow (LPM)
1000 10 20 30 40
5
VALVE SPECIFICATIONS
200
50
Nominal Flow 10 GPM (38 LPM)
Pressure Drop (PSI)
150 10
0 0 8 GPM (30 LPM) from (2) to (3)
0 2 4 6 8 10 12 Rated Operating Pressure 3000 PSI (207 bar)
100 Flow (GPM)
Port 3 to 4 Port 2 to 1
Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per path
5
50 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Flow (LPM)
Filtration ISO 18/16/13
0 0 10 20 30 40 0 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
0
200 2 4 6 8 10 12
Flow (GPM)
Weight .32 lbs (.15 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Pressure Drop (PSI)
150 0 2 4 6 8 10 12
Flow (GPM) 10
Port 2 to 3 Port 1 to 4
100
5
50
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
Page MD108
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
.75
1.50 [19.0]
[38.1]
1.25
[31.7]
2.50
3/8-24 UNF
[63.4]
2A THREAD
.61
[15.5]
1.21
.63
[15.9] 1.38
2.00 [34.9]
[50.8]
3.25
[82.6]
#6 SAE PORTS
4X
ORDERING INFORMATION
DG-M4A – –
OPTIONS BODIES
Buna, Standard 00 Blank Without Body
Viton, Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD109
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, 4 way 2 position, manual rotary spool valve, closed center.
OPERATION
The DG-M4B when rotated fully to clockwise position, this valve blocks flow at all ports. When rotated fully to
counterclockwise position, the cartridge directs flow between (2) and (1), as well as (3) and (4).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
PERFORMANCE
0 5 10 15 20 25 30 35 40 45 50 55 60 65 VALVE SPECIFICATIONS
150 10
Actual Test Data (Cartridge Only) Nominal Flow 15 GPM (57 LPM)
Rated Operating Pressure 3000 PSI (207 bar)
Pressure Drop (PSI)
Flow (LPM) Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per path
100
0 5 10 15 20 25 30 35 40 45 50 55 60 65 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
150 10 Filtration ISO 18/16/13
5
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
50
Pressure Drop (PSI)
100
Operating Fluid Media General Purpose Hydraulic Fluid
5 Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
0 0
Cavity DELTA 4W
50 0 5 10 15
Cavity Form Tool (Finishing) 40500002
Flow (GPM)
Seal Kit 21191214
Port 2 to 1 Port 3 to 4
0 0
0 5 10 15
Flow (GPM)
Port 2 to 1 Port 3 to 4
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD110
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DG-M4B – –
OPTIONS BODIES
Buna, Standard 00 Blank Without Body
Viton, Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD111
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, 4 way 2 position, manual rotary spool valve tandem center.
OPERATION
The DG-M4C when rotated fully to clockwise position, the cartridge allows flow from (2) to (4) and blocks flow at
(1) and (3). When rotated fully total counterclockwise position, the cartridge allows flow between (2) and (3) and
between (1) and (4). All ports are closed in transition.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
0 5 10
PERFORMANCE 15 20 25 30 35 40 45 50 55 60 VALVE SPECIFICATIONS
200
Actual Test Data (Cartridge Only) Nominal Flow 12 GPM (45 LPM)
8 GPM (30 LPM) from (2) to (3)
Pressure Drop (PSI)
150
Pressure Drop (bar)
10
Flow (LPM) Rated Operating Pressure 3000 PSI (207 bar)
0 5 10 15 20 25 30 35 40 45 50 55 60 Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per path
100
200 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
5
Filtration ISO 18/16/13
50
Pressure Drop (PSI)
10
Weight .52 lbs (.23 kg)
0 0 Operating Fluid Media General Purpose Hydraulic Fluid
100
0 2 4 6 8 10 12 14 16
5
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
Flow (GPM)
50 Cavity DELTA 4W
Port 1 to 4 Port 2 to 3 Port 2 to 4 Cavity Form Tool (Finishing) 40500002
Seal Kit 21191214
0 0
0 2 4 6 8 10 12 14 16
Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD112
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
DG-M4C – –
OPTIONS BODIES
Buna, Standard 00 Blank Without Body
Viton, Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD113
MECHANICAL DIRECTIONAL CONTROLS
DESCRIPTION
6 port rotary selector valve.
OPERATION
The QS-MRS when rotated counter-clockwise allows flow from (A) to (B) & (D) to (E) and
blocks (C) & (F). When rotated clockwise, the valve directs flow from (C) to (B) & (F) to (E)
and block flow at (A) & (D).
B D F
(A)(C)(E)
A C E
PERFORMANCE VALVE SPECIFICATIONS
Actual Test Data (Cartridge Only) Nominal Flow 25 GPM (95 LTR/M)
Rated Operating Pressure 3000 PSI (207 bar)
Typical Internal Leakage
(150 SSU) 1 cu in/min (16 ml/min)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight 3.42 lbs (1.55 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD114
MECHANICAL DIRECTIONAL CONTROLS
DIMENSIONS
ORDERING INFORMATION
QS-MRS – –
OPTIONS BODIES
Buna Standard 00 N 1/2” NPT Ports
Viton Standard V0 S #8 SAE Ports
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD115
MECHANICAL DIRECTIONAL CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2017
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MD116
MECHANICAL FLOW CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF1
MECHANICAL FLOW CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF2
MECHANICAL FLOW CONTROLS
TYPICAL SCHEMATIC
Typical application for an NVA/NVB is to meter flow to an actuator. In the example shown, the valve is used to allow a hydraulic motor to be
manually unloaded, so that the vehicle can be towed.
Typical application for the FCH is to meter flow in one direction while allowing free flow in the opposite direction.
(1)
FCH
NVA/
NVB
(2)
(2)
(1)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF3
MECHANICAL FLOW CONTROLS
DE-FCH ADJUSTABLE FLOW CONTROL VALVE, SPOOL TYPE, FREE REVERSE FLOW
DESCRIPTION
10 size, 7/8-14 thread, “Delta” adjustable needle flow control valve with free reverse flow.
OPERATION
The DE-FCH increases its orifice value from fully closed to fully open by turning screw counterclockwise. When
adjusted open the valves regulates flow (1) to (2). When fully closed the valve restricts flow from (1) to (2).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
0 Flow ( LPM) 0
Flow (LPM)
0 5 10 15
0 5 10 15 20 25 30 35 40 45 50 55 0 25 50 75
Flow (GPM)
300 20 500
Port 2 to 1 (valve open) Port 2 to 1 (valve closed)
30
400
Pressure Drop (PSI)
255 100
5
300 20
0 0 0 0
2000 15
5 10 15 0 5 10 15 20
Flow (GPM) 10 Flow (GPM)
100
Port 2 to 1 (valve open) Port 2 to 1 (valve closed) 5 Port 1 to 2 (valve open FINE) Port 1 to 2 (valve open STANDARD)
0 0
0 5 Flow10
(LPM) 15 20
Flow (GPM)
0 25 50 75
500 Port 1 to 2 (valve open FINE) Port 1 to 2 (valve open STANDARD)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
25
300 20
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com 15 mail: [email protected] • www.tecnord.com
200
10
MF4
Page100
5
0 0
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-FCH – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPT Ports
Buna, Knob 0K S #8 SAE Ports
Viton, Knob VK
Buna, Screen A0
Viton, Screen W0
Buna, Screen, Knob AK ADJUSTMENTS
Viton, Screen, Knob WK FINE Fine Adjustment
STRD Standard Adjustment
Note: use screen only if flow
direction is from (1) to (2).
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF5
MECHANICAL FLOW CONTROLS
DESCRIPTION
7 size, 5/8-18 thread, “Mini” series, needle flow control valve.
OPERATION
The MA-NVA adjusts from fully open to fully closed by turning adjusting screw clockwise. When adjusted open
the valve allows flow (1) to (2) and (2) to (1). When fully closed the valve blocks flow from (1) to (2) and (2) to (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Actual Test Data (Cartridge Only) Nominal Flow 6 GPM (23 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Flow (LPM) Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 5 10 15 20 25 30 Filtration ISO 18/16/13
200 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .24 lbs (.11 kg)
Pressure Drop (PSI)
0 0
0 2 4 6 8
Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF6
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
MA-NVA – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF7
MECHANICAL FLOW CONTROLS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, needle flow control.
OPERATION
The PB-NVA adjusts from fully open to fully closed by turning adjusting screw clockwise. When adjusted open the
valve allows flow from (1) to (2) and (2) to (1). When fully closed the valve blocks flow from (1) to (2) and (2) to (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 5
PERFORMANCE 10 15 20 25 30 VALVE SPECIFICATIONS
300 20
Actual Test Data (Cartridge Only) Nominal Flow 6 GPM (23 LPM)
250
Rated Operating Pressure 3500 PSI (241 bar)
Pressure Drop (PSI)
Flow (LPM) 15
200 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 5 10 15 20 25 30
Filtration ISO 18/16/13
300
150 10
20
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
250
100 Weight .22 lbs (.10 kg)
Pressure Drop (PSI)
15
5
200 Operating Fluid Media General Purpose Hydraulic Fluid
50
Cartridge Torque Requirements 25 ft-lbs (34 Nm)
150
0 10
0 Cavity POWER 2W
1000 2 4 6 8
Cavity Form Tool (Finishing) 40500005
Flow (GPM) 5
50 Seal Kit 21191102
Port 1 to 2 (valve fully open)
0 0
0 2 4 6 8
Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF8
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
PB-NVA – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
Buna, Screen A0
Viton, Screen W0
Buna, Screen, Knob AK
Viton, Screen, Knob WK
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF9
MECHANICAL FLOW CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series fine adjust needle flow control valve.
OPERATION
The DE-NVA adjusts from fully open to fully closed by turning adjusting screw counterclockwise. When adjusted
open the valve allows flow (1) to (2) and (2) to (1). When fully closed the valve blocks flow from (1) to (2) and (2)
to (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70
PERFORMANCE
450 30
VALVE SPECIFICATIONS
400
Actual Test Data (Cartridge Only) 25 Nominal Flow 10 GPM (38 LPM)
Pressure Drop (PSI)
350
300 20
Rated Operating Pressure 3500 PSI (241 bar)
250 Flow (LPM) Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
15
200 Filtration ISO 18/16/13
150 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70
10 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
450
100 30
400
5 Weight .19 lbs (.09 kg)
50
25 Operating Fluid Media General Purpose Hydraulic Fluid
Pressure Drop (PSI)
350
0 0
3000 5 10 15 20 20 Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
250 Flow (GPM) Cavity DELTA 2W
15
200
Port 1 to 2 (valve fully open) Cavity Form Tool (Finishing) 40500000
150 10
100
Seal Kit 21191202
5
50
0 0
0 5 10 15 20
Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF10
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-NVA – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Knob 0K S #8 SAE Ports
Viton, Knob VK
Buna, Screen A0
Viton, Screen W0
Buna, Screen, Knob AK
Viton, Screen, Knob WK
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF11
MECHANICAL FLOW CONTROLS
DESCRIPTION
“High Pressure” 12 size, 1 1/16-12 thread, “Tecnord” series, needle flow control valve.
OPERATION
The HT-NVA adjusts from fully open to fully closed by turning adjusting screw clockwise. When adjusted open
the valve allows flow (1) to (2) and (2) to (1). When fully closed the valve blocks flow from (1) to (2) and (2) to (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
150 10 Operating
5 Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 70 ft-lbs (95 Nm)
100
50
Cavity TECNORD 2W
5
Cavity Form Tool (Finishing) 40500032
50 0 0
Seal Kit 21191302
0 5 10 15 20 25 30 35 40
0 Flow (GPM) 0
0 5 10 15 20 25 30 35 40
FlowPort 1 to 2 (valve fully open)
(GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF12
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
HT-NVA – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 S #12 SAE Ports
Buna, Knob 0K
Viton, Knob VK
Buna, Screen A0
Viton, Screen W0
Buna, Screen, Knob AK
Viton, Screen, Knob WK
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF13
MECHANICAL FLOW CONTROLS
DESCRIPTION
16 size, 1 5/16-12 thread, “Super” series, needle flow control valve.
OPERATION
The SJ-NVA adjusts from fully open to fully closed by turning the adjustment screw clockwise. When adjusted
open the valves regulates flow (1) to (2) or (2) to (1). When fully closed the valve blocks flow from (1) to (2) or
(2) to (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
PERFORMANCE VALVE SPECIFICATIONS
0 25 50 75 100 125 150
100 Test Data (Cartridge Only)
Actual Nominal Flow 40 GPM (151 LPM)
6
Rated Operating Pressure 3500 PSI (241 bar)
Pressure Drop (PSI)
75 5
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Flow (LPM) 4
50 Filtration ISO 18/16/13
0 25 50 75 100 125 150
3
100 Media Operating Temp. Range -35° to 200°F (-37.2° to 93.3°C)
2
25 6 Weight .83 lbs (.37 kg)
Pressure Drop (PSI)
1
75 5 Operating Fluid Media General Purpose Hydraulic Fluid
0 0
4 Cartridge Torque Requirements 90 ft-lbs (122 Nm)
500 5 10 15 20 25 30 35 40
3 Cavity SUPER 2W
Flow (GPM)
Port 1 to 2 (valve fully open) 2 Cavity Form Tool (Finishing) 40500017
25
1 Seal Kit 21191402
0 0
0 5 10 15 20 25 30 35 40
Flow (GPM)
Port 1 to 2 (valve fully open)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF14
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
SJ-NVA – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/4” NPT Ports
Buna, Knob 0K S #12 SAE Ports
Viton, Knob VK
Buna, Internally Adj. 0I
Viton, Internally Adj. VI
Buna, Tamper Proof 0T
Viton, Tamper Proof VT
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF15
MECHANICAL FLOW CONTROLS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, fine adjust needle flow control.
OPERATION
The PB-NVB adjusts from fully open to fully closed by turning adjusting screw clockwise. When adjusted open
the valve allows flow (1) to (2) and (2) to (1). When fully closed the valve blocks flow from (1) to (2) and (2) to (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 5 10 15
PERFORMANCE
300
20
VALVE SPECIFICATIONS
Actual
250 Test Data (Cartridge Only) Nominal Flow 3 GPM (11 LPM)
Pressure Drop (PSI)
Flow (LPM) 15
200
0 5 10 15 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
150
300
2010 Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
250
100 Weight .13 lbs (.06 kg)
Pressure Drop (PSI)
15
200 5
50 Operating Fluid Media General Purpose Hydraulic Fluid
150 Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
10
0 0 Cavity POWER 2W
1000 1 2 3 4 5
Cavity Form Tool (Finishing) 40500005
Flow (GPM) 5
50 Seal Kit 21191102
Port 1 to 2 (valve fully open)
0 0
0 1 2 3 4 5
Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF16
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
PB-NVB – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
Buna, Screen A0
Viton, Screen W0
Buna, Screen, Knob AK
Viton, Screen, Knob WK
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF17
MECHANICAL FLOW CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, course adjust needle flow control valve.
OPERATION
The DE-NVB adjusts from fully open to fully closed by turning adjusting screw clockwise. When adjusted open
the valve allows flow (1) to (2) and (2) to (1). When fully closed the valve blocks flow from (1) to (2) and (2) to (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0
PERFORMANCE 25 50 75 VALVE SPECIFICATIONS
300 20
Actual Test Data (Cartridge Only) Nominal Flow 15 GPM (57 LPM)
250
Rated Operating Pressure 3500 PSI (241 bar)
Pressure Drop (PSI)
15
200 Flow (LPM) Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 25 50 75 Filtration ISO 18/16/13
150
300 2010 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
100
250 Weight .47 lbs (.21 kg)
Pressure Drop (PSI)
155
Pressure Drop (bar)
200
50
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
150
0 100 Cavity DELTA 2W
0 5 10 15 20
100 Cavity Form Tool (Finishing) 40500000
Flow (GPM) 5
50
Seal Kit 21191202
Port 1 to 2 (valve fully open)
0 0
0 5 10 15 20
Flow (GPM)
Port 1 to 2 (valve fully open)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF18
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-NVB – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPT Ports
Buna, Knob 0K S #8 SAE Ports
Viton, Knob VK
Buna, Screen A0
Viton, Screen W0
Buna, Screen, Knob AK
Viton, Screen, Knob WK
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF19
MECHANICAL FLOW CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF20
MECHANICAL FLOW CONTROLS
TYPICAL SCHEMATIC
Typical application for the FCA, FCB, FCC and FCF is for actuator speed control. The FCB and FCF valves have fixed, non-adjustable settings.
The FCA and FCC versions are adjustable.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF21
MECHANICAL FLOW CONTROLS
DESCRIPTION
7 size, 5/8-18 thread, “Mini” series, pressure compensated, flow control valve.
OPERATION
The cartridge maintains a constant flow rate out of (1) regardless of load pressure changes in the circuit
downstream of (1). The adjustable control differential spring load can be set to customer flow specification (see
options for ranges). The valve begins to respond to load changes when the flow through the valve creates a
pressure differential from (2) to (1) greater than 200 PSI with accurate flow maintenance from 200 to 3000 PSI
(14 to 207 bar). Reverse flow (1) to (2) returns through the control orifice and is non-compensated. The regulated
flow increases from low to high with clockwise rotation of the knob.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
1 • Fine low-torque adjustment.
Best stability is obtained with adjustment at
highest flow.
3
5 10
Flow (GPM)
Flow (GPM)
Flow (LPM)
Flow (LPM)
1 2
5
1
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Pressure Drop (PSI) Pressure Drop (PSI)
Port 2 to 1 Port 2 to 1 Port 2 to 1 Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF22
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
MA-FCA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
FLOW
0.17 .08 - .17 GPM
00.5 .25 - .5 GPM
00.9 .5 - .9 GPM
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF23
MECHANICAL FLOW CONTROLS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, pressure compensated, flow control valve.
OPERATION
The cartridge maintains a constant flow rate out of (1) regardless of load pressure changes in the circuit
downstream of (1). The adjustable control differential spring load can be set to customer flow specification (see
options for ranges). The valve begins to respond to load changes when the flow through the valve creates a
pressure differential from (2) to (1), greater than 200 PSI (14 bar), with accurate flow maintenance from 200 to
3500 PSI (14 to 241 bar). Reverse flow (1) to (2) returns through the control orifice and is non-compensated. The
regulated flow increases from low to high with clockwise rotation of the knob.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
• Fine low-torque adjustment.
HYDRAULIC SYMBOL
Actual Test Data (Cartridge Only) Nominal Flow 4 GPM (15 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Pressure Drop (bar)
Pressure Drop (bar) Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 50 100 150 200
0 5 50 100 150 200 Filtration ISO 18/16/13
5 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
4 15
Weight .26 lbs (.12 kg)
4 15 Operating Fluid Media General Purpose Hydraulic Fluid
Flow (GPM)
Flow (LPM)
3
10 Cartridge Torque Requirements 25 ft-lbs (34 Nm)
Flow (GPM)
Flow (LPM)
3 2
10
Cavity POWER 2W
5 Cavity Form Tool (Finishing) 40500005
2 1
Seal Kit 21191100
0 0 5
1 0 500 1000 1500 2000 2500 3000
Pressure Drop (PSI)
0 Port 2 to 1 Port 2 to 1 0
0 500 1000 1500 2000 2500 3000
Pressure Drop (PSI)
Port 2 to 1 Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF24
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
PB-FCA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Tamper Proof 0T S #6 SAE Ports
Viton, Tamper Proof VT
FLOW
0.45 .25 - .45 GPM
0.75 .45 - .75 GPM
1.35 .75 - 1.35 GPM
2.65 1.35 - 2.65 GPM
4.00 2.65 - 4.00 GPM
Tamper Proof
Fill in Digit Pressure Setting
Example: 02.0 - 2 GPM
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF25
MECHANICAL FLOW CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pressure compensated, flow control valve.
OPERATION
The DE-FCA maintains a constant flow rate out of (1) regardless of load pressure changes in the circuit
downstream of (1). The adjustable control (see options for ranges) differential spring load can be set to customer
flow specification. The valve begins to respond to load changes when the flow through the valve creates a
pressure differential across the control orifice greater than 100 PSI (6.9 bar), with accurate flow maintenance
from 100 to 3500 PSI (6.9 to 241 bar). Reverse flow (1) to (2) returns through the control orifice and is non-
compensated. The regulated flow increases from low to high with clockwise rotation of the knob.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
• Fine low-torque adjustment.
Best stability is obtained with adjustment at
highest flow.
Flow (LPM)
Flow (LPM)
Flow (LPM)
Flow (LPM)
0 0 0 6 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000 20
Pressure Drop (PSI) 5 Pressure Drop (PSI)
4 15
1 Port 2 to 1 Port 2 to 1 Port 2 to 1 Port 2 to 1
10
2
5
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Pressure Drop (PSI) Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF26
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-FCA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Knob 0K S #8 SAE Ports
Viton, Knob VK
FLOW
01.0 .5-1 GPM
02.0 1-2 GPM
04.0 2-4 GPM
08.0 4-8 GPM
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF27
PB-FCC Adjustable Flow Control Valve, Pressure Compensated
DESCRIPTION
FLOW CONTROLS Delta Power
8 size, 3/4-16 thread, “Power” series, pressure compensated
Company
MECHANICAL
flow control valve.
FLOW CONTROLS
4484 Boeing Drive - Rockford, IL 61109
PB-FCC ADJUSTABLEOPERATION
FLOW CONTROL VALVE, PRESSURE COMPENSATED
PB-FCC Adjustable Flow
TheControl
PB-FCC Valve, Pressure
maintains Compensated
a constant flow rate out of (1) regardless of load pressure changes in the circuit
downstream of (1).
DESCRIPTION DESCRIPTION
8 size, 3/4-16 thread, “Power” series, pressure compensated flow control valve.
8 size, 3/4-16 thread, “Power” series, pressure compensated flow control valve.
The adjustable control differential spring load can be set to customer flow specification (see options for
OPERATION
ranges).
TheOPERATION
PB-FCC maintains a constant flow rate out of (1) regardless of load pressure changes in the circuit
downstream of (1).
Thevalve
The PB-FCC maintains
begins to responda constant
to load flow rate outwhen
changes of (1)the
regardless
flow throughof load
thepressure changes
valve creates in the circuit
a pressure differential
Thefrom (2) tocontrol
downstream
adjustable (1) across the
of (1).
differential control
spring load canorifice.
be set toConsult
customer graph to see (see
flow specification regulation at high and low adjustment
options for
ranges).
settings.
The adjustable control differential spring load can be set to customer flow specification (see options for ranges).
TheThevalvevalve
beginsbegins to respond
to respond to loadto load changes
changes when thewhen the flowthe
flow through through the valve
valve creates createsdifferential
a pressure a pressure differential from
Reverse
from flow
(2)(2)toto(1)(1) (1)the
across
across to (2) returns
thecontrol
control through
orifice.
orifice. Consultthe
Consult control
graph
graph totosee
seeorifice and at
regulation
regulation is non-compensated.
at high
high and
and low
low adjustment
adjustment settings.
settings.
Reverse flow (1) to (2) returns through the control orifice and is non-compensated. The regulated flow increases
The regulated
from flow
low (1)
to high
flow increases from low to high with clockwise rotation of the knob.
Reverse to (2)with clockwise
returns through rotation
the controlof orifice
the knob.
and is non-compensated.
FEATURES
The regulated flow increases from low to high with clockwise rotation of the knob.
FEATURES
1
FEATURES
Hardened parts for long life.
• Hardened parts for long life.
Industry common cavity.
1 Hardenedcommon
• Industry parts for cavity.
long life.
Industry common cavity.
2
2
HYDRAULIC SYMBOL
VALVE SPECIFICATIONS
VALVE SPECIFICATIONS
Best
Beststability
stability isisobtained
obtainedwithwith adjustment
adjustment at at Nominal FlowNominal Flow 5 GPM (19 LPM) 5 GPM (19 LPM)
highest flow. Rated Operating Pressure 3500 PSI (241 bar) is obtained with adjustment at
highest flow. Rated Operating Pressure
Best stability3500 PSI (241 bar)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Viscosity Range highest flow.36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Filtration
Media Operating ISO 18/16/13
HYDRAULIC SYMBOL -40 to 250 F (-40 to 120 C)
TemperatureMedia
Range Operating
HYDRAULIC SYMBOL Weight .26 lbs. (.12 kg) -40 to 250 F (-40 to 120 C)
Temperature Range
Operating Fluid Media General Purpose Hydraulic Fluid
Weight
Cartridge Torque .26 lbs. (.12 kg)
2 1 Requirements
Cavity
Operating Fluid25 ft-lbs (34 Nm)
Media
POWER 2W
General Purpose Hydraulic Fluid
Cartridge Torque
PERFORMANCE
PERFORMANCE
2 1 Seal Kit
Tool (Finishing) 40500005
Cavity Form Requirements
VALVE 21191100
CavitySPECIFICATIONS
25 ft-lbs (34 Nm)
POWER 2W
Actual Test Data (Cartridge Only)
Actual Test Data (Cartridge Only)
Pressure Drop (BAR)
CavityFlow
Nominal Form
Tool (Finishing)
40500005
5 GPM (19 LPM)
PERFORMANCE0 50 100 150 200 Seal Kit
Rated Operating Pressure 21191100
3500 PSI (241 bar)
5
Actual Test Data (Cartridge Only) 18
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Regulated Flow (LPM)
Regulated Flow (GPM)
4 15
Pressure Drop (BAR) Filtration ISO 18/16/13
03 50 100 150 12 200 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
5 9
2
18 Weight .26 lbs (.12 kg)
Regulated Flow (LPM)
4 15
1
3 Cartridge Torque Requirements 25 ft-lbs (34 Nm)
3 0 12
0 Cavity POWER 2W
0 500 1000 1500 2000 2500 3000
9 Cavity Form Tool (Finishing) 40500005
Pressure Drop (PSI)
2
Port 2 to 1 Port 2 to 1 6 Seal Kit 21191100
1
WARNING: The specifications/application data shown in our catalogs 3and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
0 Phone: (815) 397-6628 0
Fax: (815) 397-2526 E-mail: [email protected]
0 500 1000 1500 2000 2500 3000
Pressure Drop (PSI)
Port 2 to 1 Port 2 to 1
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF28
FLOW CONTROLS Delta Power Company
MECHANICAL FLOW CONTROLS
4484 Boeing Drive - Rockford, IL 61109
DIMENSIONS
DIMENSIONS
2.00 [50.8]
1.12 [28.6]
1.50
.87 [22.2] 1.25
[38.1]
HEX. [31.7]
KNOB .62
[15.9]
3
16" SOCKET HEX
EXTERNAL ADJ.
2.30
INTERNAL ADJ.
[58.5]
TAMPER PROOF 3/8-24 UNF-2A
THREAD .281 [7.1] MTG. HOLE
(2X)
Tamper Proof
Fill in 4 Digit Flow Setting
Example: 02.0 - 2 GPM
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
WARNING: The specifications/application
mail: [email protected] data shown in our catalogs and data
• www.delta-power.com sheets
mail: are intended
[email protected] only as a general guide for the product described
• www.tecnord.com
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Page MF29
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]
MECHANICAL FLOW CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pressure compensated, flow control valve.
OPERATION
The DE-FCC maintains a constant flow rate out of (1) regardless of load pressure changes in the circuit
downstream of (1). The adjustable control orifice can be set to customer flow specification (see options for
ranges). The valve begins to respond to load changes when the flow through the valve creates a pressure
differential across the control orifice. Consult chart to see regulation at high and low adjustment settings. Reverse
flow (1) to (2) returns through the control orifice and is non-compensated. The regulated flow increases from low
to high with clockwise rotation of the knob.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
• Fine low-torque adjustment.
Lowest pressure drop is obtained with
adjustment at lowest setting.
Flow (LPM)
Flow (LPM)
6
8 20 30 2
3
4 15 10
25
Flow (GPM)
Flow (GPM)
5
Flow (LPM)
Flow (LPM)
6 10 1
2 20 2
5
4 15
0 0 0 0 5
0 500 1000 1500 2000 2500 3000 10 0 1 500 1000 1500 2000 2500 3000
2
Pressure Drop (PSI) 5 Pressure Drop (PSI)
Port 2 to 1 Port 2 to 1 Port 2 to 1 Port 2 to 1
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Pressure Drop (PSI) Pressure Drop (PSI)
Port 2 to 1 Port 2 to 1 Port 2 to 1 Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF30
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-FCC – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Knob 0K S #8 SAE Ports
Viton, Knob VK
FLOW
1.16 .80-1.16 GPM
1.62 1.16-1.62 GPM
2.09 1.62-2.09 GPM
2.90 2.09-2.90 GPM
3.82 2.90-3.82 GPM
5.00 3.82-5.00 GPM
8.00 5.00-8.00 GPM
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF31
FLOW CONTROLS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
FLOW CONTROLS Delta Power Company
MECHANICAL FLOW CONTROLS
4484 Boeing Drive - Rockford, IL 61109
DE-FAR Fully Adjustable Flow Control Valve, Pressure Compensated
DE-FAR Fully
DE-FAR FULLY ADJUSTABLEFlowFLOW
DESCRIPTION
Adjustable CONTROL
Control VALVE, PRESSURE
Valve, Pressure COMPENSATED
Compensated
10 size, 7/8-14 thread, “Delta” series, pressure compensated, fully adjustable flow control valve.
DESCRIPTION
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pressure compensated, fully adjustable flow control valve.
OPERATION
10 size, 7/8-14 thread, “Delta” series, pressure compensated, fully adjustable flow control valve.
The DE-FAR maintains a constant flow rate out of (1) regardless of load pressure changes in the circuit
OPERATION
downstream
The of (1). a constant flow rate out of (1) regardless of load pressure changes in the circuit
DE-FAR maintains
OPERATION
downstream
The adjustable
DE-FAR of (1).
maintains a constant
The control orifice can beflow
set rate out of (1)
to customer regardless
flow of load pressure changes in the circuit
specification.
downstream of (1). The adjustable control orifice can be
The adjustable control orifice can be set to customer flow specification.set to customer flow specification. The valve begins to
respond
The valveto begins
load changes when to
to respond theload
flow changes
through the valve
when thecreates a pressure
flow through thedifferential across
valve creates a the controldifferential
pressure orifice.
across
The valvethe
Consult chartcontrol
begins totoseeorifice.
respond toConsult
load
regulation chart
andto
at changes
high see
when
low regulation
the flow through
adjustment at high and
valvelow
the Reverse
settings. adjustment
creates
flow to (2)settings.
a pressure
(1) differential
returns through the
across theorifice
control control orifice.
and Consult chart to see
is non-compensated. Theregulation
regulatedatflowhighincreases
and low adjustment
from low to settings.
high with counterclockwise
Reverse
rotation offlow
the (1) to (2)
adjustment returns
knob. through the control orifice and is non-compensated.
Reverse flow (1) to (2) returns through the control orifice and is non-compensated.
The regulated flow increases from low to high with counterclockwise rotation of the adjustment knob.
The regulated flow increases from low to high with counterclockwise rotation of the adjustment knob.
FEATURES
FEATURES
• Hardened parts for long life.
FEATURES
• Industry commonparts
Hardened cavity.
for long
Hardened parts for long life. life.
• Fine low-torque
Industry
Industry adjustment.
common cavity.
11 Fine
Fine
common cavity.
low-torque
low-torque adjustment.
adjustment.
PERFORMANCE
PERFORMANCE
2 1 CavityRequirements DELTA 2W
KitVALVE SPECIFICATIONS21191200
Seal Cavity
30 ft-lbs (40.6 Nm)
DELTA 2W
Actual Test Data (Cartridge Only)
PERFORMANCE Seal
Actual Test Data (Cartridge Only) Max Kit
Regulated Flow 21191200
12 GPM (45 LPM)
Actual Test Data (Cartridge
PressureOnly)
Drop (BAR) Rated Operating Pressure 3500 PSI (241 bar)
0 50 100 Drop (BAR)
Pressure 150 200 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
14
0 50 100 150 50
200 Filtration ISO 18/16/13
12
Regulated Flow (LPM)
Regulated Flow (GPM)
2 20
40 0
10
2 0 500 1000 1500 2000 2500 3000
Pressure Drop (PSI)
0 0
0 Port 2 to
500 1
1000 Port
1500 Port 22500
2 to 1 2000 to 1 3000
Pressure Drop (PSI)
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
Port 2 to 1 Port 2not
(herein). Any specific application should to be
1 undertaken
Port 2 towithout
1 independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF32
FLOW CONTROLS Delta Power Company
MECHANICAL
4484 Boeing FLOW
Drive - CONTROLS
Rockford, IL 61109
DIMENSIONS
.81
1.50 [20.6]
1.52 1.00 HEX [38.1]
[38.7] [25.4]
2.61 .63
[66.3] 2.00 [16.0]
[50.8] 1.63
2.13 [41.4]
[54.1] #8 SAE PORT (2X)
Ø.281 [7.1]
1.25 .75 [19.1] MTG HOLE (2X)
[31.8] 7/8-14 UNF-2A .13 [3.2] 1.75 [44.5]
2.00 [50.8]
ORDERING INFORMATION
ORDERING INFORMATIONDE-FAR – – –
DE-FAR - - -
OPTIONS OPTIONS BODIES BODIES
Buna, ExternalBuna,
Adj. w/locknut 00
External Adj. w/locknut 00 Blank Without Body Blank Without Body
Viton, ExternalViton,
Adj. w/locknut V0
External Adj. w/locknut V0 N 3/8 NPTF Ports N 3/8 NPTF Ports
Buna, Knob Buna, 0KKnob 0K S #8 SAE Ports S #8 SAE Ports
Viton, Knob Viton, VKKnob VK
FLOW SETTING
XXXX 1 – 12 GPM
FLOW SETTING
XXXX 0-12 GPM
Preset
Example: 0005
Preset= 5 GPM +/-10%
Example: 0005 = 5 GPM ±10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability. Page MF33
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]
MECHANICAL FLOW CONTROLS
DESCRIPTION
“High Pressure” 12 size, 1 1/16 -12 thread, “Tecnord” series, pressure compensated, flow control valve.
OPERATION
The HT-FCA maintains a constant flow rate out of (1) regardless of load pressure changes in the circuit downstream
of (1). The adjustable control orifice can be set to customer flow specification (see options for ranges). The valve
begins to respond to load changes when the flow through the valve creates a pressure differential across the
control orifice. Consult chart to see regulation at high and low adjustment settings. Reverse flow (1) to (2) returns
through the control orifice and is non-compensated. The regulated flow increases from low to high with clockwise
rotation of the adjustment screw.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
1 • Fine low-torque adjustment.
Actual Test Data (Cartridge Only) Max Regulated Flow 18 GPM (68 LPM)
Rated Operating Pressure 5000 PSI (345 bar)
Pressure Drop (bar) Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 50 100 150 200 Filtration ISO 18/16/13
20 75
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .73 lbs (.33 kg)
15
50 Operating Fluid Media General Purpose Hydraulic Fluid
Flow (GPM)
Flow (LPM)
0 0
0 500 1000 1500 2000 2500 3000
Pressure Drop (PSI)
Port 2 to 1 Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF34
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
HT-FCA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 S #12 SAE Ports
Buna, Knob 0K
Viton, Knob VK
FLOW
XXXX 0-18 GPM
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF35
MECHANICAL FLOW CONTROLS
DESCRIPTION
16 size, 1 5/16 -12 thread, “Super” series, pressure compensated, flow control valve.
OPERATION
The SJ-FCA maintains a constant flow rate out of (1) regardless of load pressure changes in the circuit downstream
of (1). The adjustable control orifice can be set to customer flow specification (see options for ranges). The valve
begins to respond to load changes when the flow through the valve creates a pressure differential across the
control orifice. Consult chart to see regulation at high and low adjustment settings. Reverse flow (1) to (2) returns
through the control orifice and is non-compensated. The regulated flow increases from low to high with clockwise
rotation of the adjustment knob.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
• Fine low-torque adjustment.
HYDRAULIC SYMBOL
Actual Test Data (Cartridge Only) Nominal Flow 25 GPM (95 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Pressure Drop (bar) Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 50 100Drop (bar) 150
Pressure 200 Filtration ISO 18/16/13
20 75 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
0 50 100 150 200
20 75 Weight .89 lbs (.40 kg)
15 Operating Fluid Media General Purpose Hydraulic Fluid
50 Cartridge Torque Requirements 90 ft-lbs (122 Nm)
Flow (GPM)
Flow (LPM)
15
10 50 Cavity SUPER 2W
Flow (GPM)
Flow (LPM)
Port 2 to 1 Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF36
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
SJ-FCA – – –
OPTIONS BODIES
Buna, External Adj. w/locknut 00 Blank Without Body
Viton, External Adj. w/locknut V0 N 3/4” NPT Ports
Buna, Knob 0K S #12 SAE Ports
Viton, Knob VK
Buna, Internally Adj. 0I
Viton, Internally Adj. VI FLOW SETTING
Buna, Tamper Proof 0T XXXX 0-25 GPM
Viton, Tamper Proof VT
Preset & Tamper Proof
Example: 0015 – 15 GPM ±10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF37
MECHANICAL FLOW CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, fixed pressure compensated, flow control valve.
OPERATION
The DE-FCB maintains a constant flow rate out of (1) regardless of load pressure changes in the circuit downstream
of (1). The valve begins to respond to load changes when the flow through the valve creates a pressure differential
across the control orifice, in excess of the spring load. Consult chart for regulation performance. Reverse flow (1)
to (2) returns through the control orifice and is non-compensated.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
6
20
Actual Test Data (Cartridge Only) Max Regulated Flow 8 GPM (30 LPM)
4 15
Rated Operating Pressure 3500 PSI (241 bar)
Pressure Drop (bar)
10 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
2 0 50 100 150 200
5 Filtration ISO 18/16/13
10
0 0 35 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
80 500 1000 1500 2000 2500 3000
30 Weight .29 lbs (.13 kg)
Pressure Drop (PSI)
25 Operating Fluid Media General Purpose Hydraulic Fluid
Flow (GPM)
Flow (LPM)
6 Port 2 to 1 Port 2 to 1
20 Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
4 15 Cavity DELTA 2W
Cavity Form Tool (Finishing) 40500000
10
2 Seal Kit 21191204
5
0 0
0 500 1000 1500 2000 2500 3000
Port 2 to 1 Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF38
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-FCB – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPT Ports
S #8 SAE Ports
FLOW SETTING
01.0 1 GPM
02.0 2 GPM
03.0 3 GPM
04.0 4 GPM
05.0 5 GPM
06.0 6 GPM
07.0 7 GPM
08.0 8 GPM
± 15%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF39
MECHANICAL FLOW CONTROLS
FLOW CONTROLS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
PB-FCF FIXED FLOW CONTROL VALVE, PRESSURE COMPENSATED
PB-FCF Fixed Flow Control Valve, Pressure Compensated
DESCRIPTION
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, pressure compensated flow control valve.
8 size, 3/4-16 thread, “Power” series, pressure compensated flow control valve.
OPERATION
OPERATION
ThePB-FCF
The PB-FCFmaintains
maintains a constant
constantflow
flowrate outout
rate of (1) regardless
of (1) of load
regardless pressure
of load changes
pressure in the circuit
changes in the downstream
circuit
downstream of (1).begins to respond to load changes when the flow through the valve creates a pressure differential
of (1). The valve
across the control orifice, in excess of the spring load. Consult graph for regulation performance.
The valve begins to respond to load changes when the flow through the valve creates a pressure differential
Reverse
across the flow (1) orifice,
control to (2) returns through
in excess of thethe control
spring orifice
load. and is
Consult non-compensated.
graph for regulation performance.
Reverse flow (1) to (2) returns through the control orifice and is non-compensated.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
FEATURES
1 Hardened parts for long life.
Industry common cavity.
VALVE SPECIFICATIONS
Best stability version for high differential circuits. Nominal Flow 6 GPM (22 LPM)
HYDRAULIC SYMBOL
Rated Operating Pressure 3500 PSI (241 bar)
Viscosity Range 36 to
Best 3000 SSU
stability (3 to for
version 647 high
cSt) differential
Filtration ISO 18/16/13
circuits.
Media Operating
HYDRAULIC SYMBOL -40 to 250 F (-40 to 120 C)
Temperature Range
Weight .26 lbs. (.12 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
2 1 Cartridge Torque
Requirements
25 ft-lbs (34 Nm)
Cavity POWER 2W
Cavity Form Tool (Finishing) 40500005
PERFORMANCE
PERFORMANCE SealVALVE
Kit SPECIFICATIONS 21191100
Actual Test Data (Cartridge Only)
Actual Test Data (Cartridge Only) Maximum Flow 6 GPM (23 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .26 lbs (.12 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 25 ft-lbs (34 Nm)
Cavity POWER 2W
Cavity Form Tool (Finishing) 40500005
Seal Kit 21191100
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF40
FLOW CONTROLS Delta Power Company
MECHANICAL FLOW
4484 Boeing Drive CONTROLS
- Rockford, IL 61109
DIMENSIONS
2.00 [50.8]
1.12 [28.6]
#6 SAE PORT
.25
1.50 [38.1] (2X)
[6.3]
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability. Page MF41
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, fixed pressure compensated, flow control valve.
OPERATION
The DE-FCF maintains a constant flow rate out of (1) regardless of load pressure changes in the circuit downstream
of (1). The valve begins to respond to load changes when the flow through the valve creates a pressure differential
across the control orifice, in excess of the spring load. Consult chart for regulation performance. Reverse flow (1)
to (2) returns through the control orifice and is non-compensated.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
25
6
PERFORMANCE VALVE SPECIFICATIONS
20
Flow (GPM)
Flow (LPM)
Actual
4 Test Data (Cartridge Only) 15 Maximum Flow 8 GPM (30 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Pressure Drop (bar) 10
2 0 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
50 100 150 200
5 Filtration ISO 18/16/13
8 30
0 0 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
0 500 1000 1500 2000 2500 3000 25 Weight .32 lbs (.15 kg)
6
Pressure Drop (PSI) 20
Operating Fluid Media General Purpose Hydraulic Fluid
Flow (GPM)
Flow (LPM)
0 0
0 500 1000 1500 2000 2500 3000
Pressure Drop (PSI)
Port 2 to 1 Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF42
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-FCF – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPT Ports
S #8 SAE Ports
FLOW SETTING
01.0 1 GPM
02.0 2 GPM
03.0 3 GPM
04.0 4 GPM
05.0 5 GPM
06.0 6 GPM
07.0 7 GPM
08.0 8 GPM
± 15%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF43
MECHANICAL FLOW CONTROLS
DESCRIPTION
16 size, 1 5/16-12 thread, “Super” series, fixed pressure compensated, flow control valve.
OPERATION
The SJ-FCF maintains a constant flow rate out of (1) regardless of load pressure changes in the circuit downstream
of (1). The valve begins to respond to load changes when the flow through the valve creates a pressure differential
across the control orifice, in excess of the spring load. Consult chart for regulation performance. Reverse flow (1)
to (2) returns through the control orifice and is non-compensated.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Actual Test Data (Cartridge Only) Flow Rate As specified from 5-25 GPM
(19-95 LPM)
Pressure Drop (BAR) Rated Operating Pressure 3500 PSI (241 bar)
0 50 100 150 200 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
25 Filtration ISO 18/16/13
90
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
20 Weight .65 lbs (.29 kg)
(GPM)
(LPM)
Flow (GPM)
Flow (LPM)
10 Cavity SUPER 2W
30 Cavity Form Tool (Finishing) 40500017
5 Seal Kit 21191400
0 0
0 500 1000 1500 2000 2500 3000
Pressure Drop (PSI)
Port 2 to 1 Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF44
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
SJ-FCF – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N ¾ NPT Ports
S #12 SAE Ports
FLOW SETTING
0010 10 GPM
0025 25 GPM
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
Page MF45
MECHANICAL FLOW CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF46
MECHANICAL FLOW CONTROLS
LS STEERING PRIORITY
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF47
FLOW CONTROLS Delta Power Company
MECHANICAL FLOW CONTROLS
4484 Boeing Drive - Rockford, IL 61109
OW CONTROLS
PP-FCQ ADJUSTABLE PRIORITY FLOW CONTROL VALVE
Delta Power Company
PP-FCQ Adjustable Priority Flow Control Valve 4484 Boeing Drive - Rockford, IL 61109
DESCRIPTION
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, adjustable priority flow control valve.
8 size, 3/4-16 thread, “Power” series, adjustable priority flow control valve.
FCQ Adjustable PriorityOPERATION
Flow Control Valve
The PP-FCQ allows pressure compensated flow from (3) to (1) regulated by the pressure present at (3).
DESCRIPTION
OPERATION
Excess flow bypasses out (2).
8 size, 3/4-16
The thread,
PP-FCQ“Power” series,compensated
allows pressure adjustable priority flow
flow from (3)control valve. by the pressure present at (3).
to (1) regulated
Excess flow bypasses out (2).
OPERATION
FEATURES
The PP-FCQ allows pressure compensated flow from (3) to (1) regulated by the pressure present at (3).
FEATURES
Excess flow Hardened parts(2).
bypasses for long life.
• Hardenedout
parts for long life.
Industry common cavity.
• Industry common cavity.
FEATURES
1
Hardened parts for long life.
Industry common
HYDRAULIC SYMBOLcavity. VALVE SPECIFICATIONS
2 2 Nominal Flow 5 GPM (19 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
3 3 1
ISO 18/16/13
Filtration
1
HYDRAULIC SYMBOL
Media Operating Temperature
-40 to 250 F (-40 to 120 C)
Range
Weight .56 lbs.Test
(.25 data
kg) shown on this sheet, for condition of port
HYDRAULIC
Test data shown on this sheet,SYMBOL
for condition of port VALVEFluid
Operating SPECIFICATIONS
Media General(2) to tank.
Purpose Data onFluid
Hydraulic next page, for condition of port
2 (2) to tank. Data on next page, for condition of port
(3) to tank. 2 NominalTorque
Cartridge Flow (3)
5 to
GPMtank.
25 ft-lbs (33.8 Nm)
(19 LPM)
Requirements
Rated Operating PressurePOWER 3500
Cavity 3W PSI (241 bar)
ViscosityForm Range 4050002436 to 3000 SSU (3 to 647 cSt)
3 PERFORMANCE 3 Only)
Actual Test Data (Cartridge 1
Cavity Tool (Finishing)
21191106
Seal Kit
ISO 18/16/13
Filtration
Media Operating Temperature
-40 to 250 F (-40 to 120 C)
Range
PERFORMANCE Weight VALVE SPECIFICATIONS .56 lbs. (.25 kg)
Test data shown on this sheet, for condition of port Operating Fluid Media General Purpose Hydraulic Fluid
(2) Actual
to tank. Data
Test Dataon next page,
(Cartridge for condition of port
Only) Nominal Flow
Cartridge Torque
5 GPM (19 LPM)
(3) to tank. Rated Operating Pressure 25 ft-lbs (33.8 Nm)(241 bar)
3500 PSI
Requirements
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Cavity POWER 3W
Filtration ISO 18/16/13
FORMANCE Cavity Form Tool (Finishing) 40500024
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
al Test Data (Cartridge Only) Seal Kit 21191106
Weight .56 lbs (.25 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 25 ft-lbs (33.8 Nm)
Cavity POWER 3W
Cavity Form Tool (Finishing) 40500024
Seal Kit 21191106
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF48
NING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
n). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
MECHANICAL FLOW CONTROLS
FLOW CONTROLS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
DIMENSIONS
1.13
[28.6]
1.50 1.25
.87 [22.2]
[38.1] [31.8]
HEX. .63
KNOB [15.9]
3
16" SOCKET HEX
EXTERNAL ADJ.
2.30
INTERNAL ADJ. [58.5]
TAMPER PROOF 3/8-24 UNF-2A
THREAD Ø.281 [7.1] (2X)
MTG. HOLE
.25 [6.3]
.58
[14.8]
1.17
3.95 [29.7]
[100.2]
3.21 .22 [5.5] 2.25
2.50
[57.2]
[81.4] [63.5]
3/4-16 UNF-2A
1.61 THREAD #6 SAE PORT
(3X)
[41.0]
Tamper Proof
Fill in 4 Digit Flow Setting
Example: 01.0 - 1.0 GPM
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product
Page described
MF49
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]
MECHANICAL FLOW CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, adjustable priority flow control valve.
OPERATION
The DF-FCQ allows pressure compensated flow from (3) to (1) regulated by the pressure present at (3). Excess
flow bypasses out (2).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF50
MECHANICAL FLOW CONTROLS
12 25
Flow (LPM)
45
Flow (GPM)
35
Flow (LPM)
8 30
6
8 40
30
10 20
25
Flow (LPM)
Flow
Flow (GPM)
35
Flow (LPM)
25
ow (GP
6 6
8 30 4 15
20 20
Flated
Regulated
Regulated
Regulated
4 25
15 10
6
Regul
4 15
20
10 2
Regulated
Regulated
Regulated
Regulated
2 5
4 15
5 10
10 2
0 0 0 0
2 5
0 500 1000 1500 2000 2500 30005 0 500 1000 1500 2000 2500 3000
0 Pressure @ Port 2 (PSI) 0 0 Pressure @ Port 2 (PSI) 0
0 500 1000 1500 2000 2500 3000 0 5002-05 @ 21000
gpm setting 15002-05 @ 52000
gpm setting 2500 3000
6-10 @ 6 gpm setting 6-10 @ 10 gpm setting
Pressure @ Port 2 (PSI) Pressure @ Port 2 (PSI)
2-05 @ 2 gpm setting 2-05 @ 5 gpm setting
6-10 @ 6 gpm setting 6-10 @ 10 gpm setting
DIMENSIONS DF-FCQ
DF-FCQ
ORDERING INFORMATION
DF-FCQ – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
FLOW RANGE
2-05 2 to 5 GPM
6-10 6 to 10 GPM
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF51
FLOW CONTROLS Delta Power Company
4484 Boeing Drive
MECHANICAL - Rockford,
FLOW IL 61109
CONTROLS
DF-FAP
DF-FAP Fully
FULLYAdjustable
ADJUSTABLEPriority Flow FLOW
PRIORITY Control Valve With
CONTROL VALVEBypass
WITH BYPASS
DESCRIPTION
DESCRIPTION
FLOW CONTROLS1010size, 7/8-14 thread, “Delta” series, fully adjustable priority flow control valve with bypass
Delta
size, 7/8-14 thread, “Delta” series, fully adjustable priority flow control Power
valve with bypass. Company
OPERATION 4484 Boeing Drive - Rockford, IL 61109
OPERATION
The
TheDF-FAP
DF-FAP allows pressurecompensated
allows pressure compensated flow
flow from
from (3)(1),
(3) to to regulated
(1), regulated
by theby the pressure
pressure present present
at (3). at (3).
DF-FAP Fully Excess Priority
Adjustable flow bypasses
Flow out (2). CanValve
Control be used as aBypass
With restrictive pressure compensated flow control when the
Excess flow bypasses out (2). Can be used as a restrictive pressure compensated flow control when the bypass
bypass port (2) is blocked.
port (2) is blocked.
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, fully adjustable priority flow control valve with bypass
FEATURES
FEATURES
• OPERATION
Hardened cage and spool for long life.
Hardened cage and spool for long life.
• Industry common
Industry cavity.
common cavity.compensated flow from (3) to (1), regulated by the pressure present at (3).
The DF-FAP allows pressure
Excess flow bypasses out (2). Can be used as a restrictive pressure compensated flow control when the
bypass port (2) is blocked. When used as a bypass flow control in applications where
1 HYDRAULIC SYMBOL VALVE SPECIFICATIONS
the priority flow port will be blocked by external valving,
2
Maximum Regulated
FEATURES
Flow drop will
bypass pressure 10 GPM (38 LPM)
increase unless a small amount
2 Rated Operating of leakage is provided 3000
Pressure for thePSIpriority port. Consult factory.
(207bar)
3 Hardened cage 1 and spool for long life.
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Industry common cavity.
3 Filtration ISO 18/16/13
Media Operating
-40 to 250 F (-40 to 120 C)
1 HYDRAULIC SYMBOL Temperature Range
VALVE SPECIFICATIONS
HYDRAULIC SYMBOL
When used as a bypass flow control in applications VALVE
Weight SPECIFICATIONS .40 lbs. (.18 kg)
where the priority flow port will be 2blocked by
Maximum Regulated Flow 10 GPM (38 LPM)
2
external valving, bypass pressure drop will increase
Operating
Max Regulated
Rated Fluid Media
Flow
Operating
Pressure General
300010PSI Purpose
GPM Hydraulic Fluid
(38 LPM)
(207bar)
3 1 for Cartridge
Rated
Viscosity Torque
Operating
Range Pressure 3000 PSI (207 bar)
unless a small amount of leakage is provided 30 ft-lbs (40.6 Nm) to 647 cSt)
36 to 3000 SSU (3
the3priority port. Consult factory. Requirements
Viscosity
FiltrationRange ISO 36 to 3000 SSU (3 to 647 cSt)
18/16/13
Cavity
Filtration
Media Operating DELTA ISO3W 18/16/13
-40 -40°
to 250 F (-40 toto120 C)
PERFORMANCE Temperature
Media
Cavity Operating
Form Tool Range
Temp. Range
(Finishing) 40500001 to 250°F (-40° 120°C)
When used as a bypass flow control in applications Weight
Weight .40 lbs. (.18(.18
kg)kg)
Actual Test Data (Cartridge Seal Kit 21191210.40 lbs
where the priorityOnly)
flow port will be blocked by Operating Fluid Media General Purpose HydraulicFluid
Fluid
Operating Fluid Media General Purpose Hydraulic
external valving,
Pressure @bypass pressure drop will increase
Port 1 (BAR) Pressure @ Port 2 (BAR)
Cartridge
Cartridge Torque Requirements
Torque 30 ft-lbs (40.6 Nm)
unless a small amount of leakage is provided for 30 ft-lbs (40.6 Nm) 200
0 the 50
priority port.100 150
Consult factory. 200 Requirements
Cavity 0 50 100 DELTA 1503W
PERFORMANCE
12 45 12
Cavity
Cavity Form Tool (Finishing) DELTA 3W
40500001 45
40 Seal Kit Form Tool (Finishing) 21191210 40
PERFORMANCE
Actual
10 Test Data (Cartridge Only) Cavity
10 40500001
Regulated Flow (LPM)
35 35
Actual
8 Test Data (Cartridge Only) Seal
8
Kit 21191210
30 30
Pressure @ Port 1 (BAR) 25 Pressure @ Port 2 (BAR) 25
6 6
0 50 100 150 20020 0 50 100 150 200 20
4 12 1545 412 15
45
1040 10
40
2 10 210
Regulated Flow (LPM)
5 35 5
35
0 8 0 30 08 0
30
0 500 1000 1500 2000 2500 3000 25 0 500 1000 1500 2000 2500
300025
6 6
Pressure @ Port 1 (PSI) 20 Pressure @ Port 2 (PSI) 20
4 GPM setting
2 6 GPM setting 10 GPM setting 15 4 2 GPM setting 6 GPM setting 10 GPM setting 15
10 10
2 2
5 5
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Pressure @ Port 1 (PSI) Pressure @ Port 2 (PSI)
2 GPM setting 6 GPM setting 10 GPM setting 2 GPM setting 6 GPM setting 10 GPM setting
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein).
Page MF52 Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]
FLOW CONTROLS Delta Power Company
MECHANICAL FLOW CONTROLS
4484 Boeing Drive - Rockford, IL 61109
DIMENSIONS
2.50 [63.4]
1.25
[31.7]
WITH KNOB
ORDERING INFORMATION
ORDERING INFORMATION
DF-FAPDF-FAP
- –
- –
- –
OPTIONS BODIES
Buna, Standard 00 Blank Without Body
Viton, Standard OPTIONS
V0 N 3/4 NPTF Ports BODIES
Buna, KnobBuna 0K Standard 00 S #12 SAE PortsBlank Without Body
Viton, Knob Viton Standard
VK V0 N 3/4” NPTF Ports
Buna, Knob 0K FLOW SETTING S #12 SAE Ports
Viton, Knob VK
XXXX 1 to 10 GPM
FLOW SETTING
XXXX
PRESET1 to 10 GPM
Example 0005 = 5 GPM +/- 10%
Preset & Tamper Proof
Example: 0005 - 5 GPM ±10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF53
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
MECHANICAL FLOW CONTROLS
DESCRIPTION
16 size, 1 5/16-12 thread, “Super” series, adjustable priority flow control valve.
OPERATION
The SK-FCQ allows pressure compensated flow from (3) to (1) regulated by the pressure present at (3). Excess
flow bypasses out (2). The spring chamber is constantly vented at (1).
FEATURES
• Hardened cage and spool for long life.
• Industry common cavity.
Flow (GPM)
Flow (LPM)
25 25
Regulated Flow (GPM)
(GPM)
(LPM)
010 0 100 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
25 25
5 Pressure @ Port 2 (PSI) 5 Pressure @ Port 1 (PSI)
priority port 1 loaded, bypass port 2 unloaded
bypass port 2 loaded, priority port 1 unloaded
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Pressure @ Port 2 (PSI) Pressure @ Port 1 (PSI)
priority port 1 loaded, bypass port 2 unloaded
bypass port 2 loaded, priority port 1 unloaded
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF54
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
SK-FCQ – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/4” NPTF Ports
Buna, Knob 0K S #12 SAE Ports
Viton, Knob VK
Buna, Internally Adj. 0I FLOW SETTING
Viton, Internally Adj. VI XXXX 1 to 25 GPM
Buna, Tamper Proof 0T
Preset & Tamper Proof
Viton, Tamper Proof VT
Example: 0015 - 15 GPM ±10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF55
FLOW CONTROLS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
MECHANICAL FLOW CONTROLS
W CONTROLS
PP-FCP Fixed Priority Flow Control Valve
PP-FCP FIXED PRIORITY FLOW CONTROL VALVE
Delta Power Company
DESCRIPTION 4484 Boeing Drive - Rockford, IL 61109
8 DESCRIPTION
size, 3/4-16 thread, “Power” series, fixed priority flow control valve.
8 size, 3/4-16 thread, “Power” series, fixed priority flow control valve.
CP Fixed Priority Flow Control Valve
OPERATION
The PP-FCP allows pressure compensated flow from (3) to (1) regulated by the pressure present at (3).
DESCRIPTION
OPERATION
Excess flow bypasses out (2).
8 size, 3/4-16The
thread, “Power”
PP-FCP allows series,
pressurefixed priority flow
compensated flowcontrol
from (3)valve.
to (1) regulated by the pressure present at (3).
Excess flow bypasses out (2).
OPERATION
The PP-FCP allows pressure compensated flow from (3) to (1) regulated by the pressure present at (3).
FEATURES
FEATURES
Excess flow •bypasses outparts
Hardened
Hardened (2).
parts
for for
longlong
life.life.
Industry common cavity.
• Industry common cavity.
1
FEATURES
Hardened parts for long life. Test data shown on this sheet, for condition of port
2 Industry common cavity. (2) to tank. Data on next page, for condition of port
HYDRAULIC SYMBOL (3) to tank.
VALVE SPECIFICATIONS
2 Nominal Flow 5 GPM (19 LPM)
1
3 Rated Operating Pressure 3500 PSI (241 bar)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
3 1
HYDRAULIC SYMBOL Filtration ISO 18/16/13
2 Media Operating Temperature
-40 to 250 F (-40 to 120 C)
HYDRAULIC SYMBOL VALVE SPECIFICATIONS
Range
Weight .56 lbs.
(19(.25 kg)
2 sheet, for condition of port Nominal
Test data shown on this Flow 5 GPM LPM)
Operating Fluid Media General Purpose Hydraulic Fluid
3 (2) to tank. Data on next page, for condition of port Rated Cartridge
(3) to tank.
Operating Pressure
Torque 3500 PSI (241 bar)
25 ft-lbs (34 Nm)
Requirements
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
3 1 Cavity POWER 3W
Filtration ISO 18/16/13
PERFORMANCE Cavity Form Tool (Finishing) 40500024
Actual Test Data (Cartridge Only) Media Seal
Operating
Kit Temperature 21191106
-40 to 250 F (-40 to 120 C)
Range
Weight .56 lbs. (.25 kg)
PERFORMANCE
Test data shown on this sheet, for condition of port VALVE SPECIFICATIONS
Operating Fluid Media General Purpose Hydraulic Fluid
(2) toActual
tank. Test
DataData
on next page,Only)
(Cartridge for condition of port Cartridge Torque
Maximum Flow 5 GPM (19 LPM)
(3) to tank. 25 ft-lbs (34 Nm)
Requirements
Rated Operating Pressure 3500 PSI (241 bar)
Cavity Viscosity Range POWER 3W36 to 3000 SSU (3 to 647 cSt)
ORMANCE Cavity Form Tool (Finishing)
Filtration 40500024 ISO 18/16/13
Test Data (Cartridge Only) Seal Kit Media Operating Temp. 21191106
Range -40° to 250°F (-40° to 120°C)
Weight .56 lbs (.25 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 25 ft-lbs (34 Nm)
Cavity POWER 3W
Cavity Form Tool (Finishing) 40500024
Seal Kit 21191106
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF56
NG: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
. Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
FLOW CONTROLS Delta Power Company
MECHANICAL FLOW CONTROLS
4484 Boeing Drive - Rockford, IL 61109
DIMENSIONS
1.13
[28.6]
1.25
[31.8]
.63
[15.9]
.22 [5.5]
1.18 Ø.281 [7.1] (2X)
2.82 [29.9] MTG. HOLE
[71.6]
3/4-16 UNF-2A .25 [6.3]
1.61 THREAD .58
[14.8]
1.17
[41.0] [29.7]
2.25
[57.2] 2.50
[63.5]
#6 SAE PORT
(3X)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF57
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
MECHANICAL FLOW CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, fixed priority flow control valve.
OPERATION
The DF-FCP allows pressure compensated flow from (3) to (1) regulated by the pressure present at (3). Excess
flow bypasses out (2). The spring chamber is constantly vented at (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
35 35
Regulated Flow (LPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF58
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DF-FCP – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
FLOW SETTING
01.0 1 GPM
02.0 2 GPM
03.0 3 GPM
04.0 4 GPM
05.0 5 GPM
06.0 6 GPM
07.0 7 GPM
08.0 8 GPM
09.0 9 GPM
10.0 10 GPM
± 15%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF59
MECHANICAL FLOW CONTROLS
DESCRIPTION
16 size, 1 5/16-12 thread, “Super” series, fixed priority flow control valve.
OPERATION
The SK-FCP allows pressure compensated flow from (3) to (1) regulated by the pressure present at (3).
Excess flow bypasses out (2). The spring chamber is constantly vented at (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
20
Regulated Flow (LPM)
75 20 75
Regulated Flow (GPM)
20 5
Regulated Flow (LPM)
75 5 20 75
Regulated Flow (GPM)
15 15
15 0 60 60
0 0 15 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
45 45
10 Pressure @ Port 2 (PSI) 10 Pressure @ Port 1 (PSI)
30 30
- Bypass port 2 loaded, priority port 1 unloaded - Priority port 1 loaded, bypass port 2 unloaded
5 5
15 15
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Pressure @ Port 2 (PSI) Pressure @ Port 1 (PSI)
- Bypass port 2 loaded, priority port 1 unloaded - Priority port 1 loaded, bypass port 2 unloaded
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF60
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
SK-FCP – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/4 NPTF Ports
S #12 SAE Ports
FLOW SETTING
001
0 10 GPM
002
5 25 GPM
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF61
FLOW CONTROLS Delta Power Company
MECHANICAL FLOW CONTROLS
4484 Boeing Drive - Rockford, IL 61109
FLOW CONTROLS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
DG-PDS STEERING PRIORITY FLOW CONTROL VALVE WITH STATIC LOAD SENSE
DG-PDS Steering Priority Flow Control Valve with Static Load Sense
DESCRIPTION
DESCRIPTION
DG-PDS Steering Priority Flow Control Valve with Static Load Sense
1010size,
size,7/8-14
7/8-14thread,
thread, “Delta” series, steering
“Delta” series, steeringpriority
priorityflow
flow control
control valve
valve with
with static
static loadload sense.
sense.
W CONTROLS DESCRIPTION Delta Power Company
OPERATION
10 size, 7/8-14 thread, “Delta” series, steering priority flow
OPERATION 4484control
Boeingvalve
Drivewith static load
- Rockford, IL sense.
61109
The
TheDG-PDS
DG-PDS allows priorityflow
allows priority flowfrom
from
(2)(2) to (1)
to (1) regardless
regardless of pressure
of load load pressure at port
at either either
(1) port (1)(3).
or port or port (3).
OPERATION
Excess flow bypasses out (3).
Excess flow bypasses out (3). Port (4) is the load sense port.
The DG-PDS allows priority flow from (2) to (1) regardless of load pressure at either port (1) or port (3).
PDS Steering Priority FlowPort
Control
(4) isflow
Excess
Valve withport.
the bypasses
load senseout
Static
(3).
Load Sense
FEATURES
DESCRIPTION
1 7/8-14
10 size, Port (4) is “Delta”
• thread,
FEATURES
the load
Hardened cage sense port.
and spool
series, for long
steering life. flow control valve with static load sense.
priority
• Industry common cavity.
1
OPERATION Hardened cage and spool for long life.
FEATURES
The2DG-PDS allows priority common
Industry flow fromcavity.
(2) to (1) regardless of load pressure at either port (1) or port (3).
Excess flow bypasses out (3). cage and spool for long life.
Hardened
2 Industry common cavity.
Port (4) is the load sense port.
HYDRAULIC SYMBOL VALVE SPECIFICATIONS
3 4 1 3
Max Regulated Flow 9 GPM (34 LPM)
1 3
FEATURESHYDRAULIC SYMBOL VALVE SPECIFICATIONS
Rated Operating Pressure 3000 PSI (207 bar)
4 1 3 Max Regulated Flow
4 Viscosity Range 369to
GPM3000 (34
SSULPM)(3 to 647 cSt)
Hardened cage and spool for long life. Rated Operating Pressure 3000 PSI (207 bar)
2 Industry common cavity. Filtration ISO 18/16/13
4 Viscosity
Media Operating Range 36 to 3000 SSU (3 to 647 cSt)
-40 to 250 F (-40 to 120 C)
HYDRAULIC SYMBOL Temperature
Filtration
VALVE Range
SPECIFICATIONS ISO 18/16/13
HYDRAULIC SYMBOL 2 Weight
Media Operating
VALVE SPECIFICATIONS 0.38 lbs. (0.17 kg)
3 Max Regulated Flow
Temperature
Operating FluidRange
Media
-409 to
GPM250(34FLPM)
(-40 to 120 C)
4 1 3 Max RegulatedRatedFlow
Operating Pressure9 GPM
(34 General
LPM)3000Purpose Hydraulic Fluid
PSI (207 bar)
2 Weight
Cartridge Torque 0.38 lbs. (0.17 kg)
Rated Operating Pressure
Viscosity Range 3000 PSI (207 bar)
30 ft-lbs (40.6
36 to 3000Nm)
SSU (3 to 647 cSt)
Requirements
Operating Fluid Media General Purpose Hydraulic Fluid
4 Viscosity Range
Filtration
Cavity
Cartridge Torque
36 to 3000 SSU (3
ISOto18/16/13
DELTA 4W
647 cSt)
Filtration Media Operating Temp.ISO 18/16/13
Range 30 ft-lbs
-40° to(40.6
250°FNm)
(-40° to 120°C)
PERFORMANCE Requirements
Cavity Form Tool (Finishing) 40500002
Media Operating
Weight
Cavity DELTA0.38 lbs
4W (.17 kg)
Actual Test Data (Cartridge Only) Temperature Seal Kit
Range
-40 to 25021191214
F (-40 to 120 C)
PERFORMANCE Operating
Cavity Form Fluid Tool
Media(Finishing)
General Purpose Hydraulic Fluid
40500002
2 Weight 0.38 lbs. (0.17 kg)
Actual Test Data (Cartridge Only) Cartridge
Seal KitTorque Requirements 30 ft-lbs (40.6 Nm)
21191214
Operating Fluid
CavityMedia
General PurposeDELTA Hydraulic
4W Fluid
PERFORMANCE Cartridge Torque
30 ft-lbs
Cavity Form Tool (Finishing) (40.6 Nm) 40500002
Requirements
Actual Test Data (Cartridge Only) Seal Kit 21191214
Priority port 1 loaded, bypass port 3 unloaded Cavity DELTA
Bypass port 4W priority port 1 unloaded
3 loaded,
FORMANCE (100 PSI spring option) Cavity Form Tool (Finishing) 40500002 (100 PSI spring option)
al Test Data (Cartridge Only)
Pressure at port 1 (BAR)
Priority port 1 loaded, bypass port 3 unloaded Seal Kit Pressure
21191214 at Port
Bypass port 3 loaded, 3 (BAR)
priority port 1 unloaded
0 50 (100 PSI100
spring option)
150 200 0 50 100
(100 PSI 150
spring option) 200
8 Pressure at port 1 (BAR) 30 8 Pressure at Port 3 (BAR) 30
Regulated Flow (GPM)
20 20
Priority 25 Bypass port 3 loaded, priority port 1 unloaded 25
46port 1 loaded, bypass port 3 unloaded 15 46 15
(100 PSI spring option) 20 (100 PSI spring option) 20
Pressure at port 1 (BAR) 10 Pressure at Port 3 (BAR) 10
24 15 0 2 450 15
0 50 100 150 200 5 100 150 200
5
8 30 10 8 30 10
Regulated Flow (GPM)
02 0 02 0
0 500 1000 1500 2000 25
2500 3000 5 0 500 1000 1500 2000 25
2500 3000 5
6 6
0 Pressure at port 1 (PSI) 20 0 Pressure at Port 3 (PSI) 20
0 0
0 500 1000 Port
1500
2 to 1 2000 2500 3000 0 500 1000Port1500
2 to 1 2000 2500 3000
4 15 4 15
Pressure at port 1 (PSI) Pressure at Port 3 (PSI)
10 10
2 Port 2 to 1 2 Port 2 to 1
5 5
0 0 sheets are intended only
WARNING: the specifications/application data shown in our catalogs and data 0 as a general guide for the product described (herein). Any specific application should0not be undertaken
W 6 / 2020
0 WARNING: The
1000specifications/application
500 independent
without study, 1500 2000
evaluation, and data shown
2500
testing for suitability. 3000 in our catalogs and0 data sheets 500 are1000 intended1500 only as 2000a general2500 guide for the product described
3000
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Pressure at port 1 (PSI) Pressure at Port 3 (PSI)
WARNING: The Phone: (815) 397-6628 data shown in our Fax:
specifications/application catalogs(815)and 397-2526
data sheets are intended E-mail: [email protected]
Port 2 to 1 Port 2onlyto 1as a general guide for the product described
(herein). Any
4484 Boeing specific
Drive Rockford,application
IL 61109 • USA should
• Phonenot be undertaken
+1 (815) 397-6628 • Faxwithout independent
+1 (815) 397-2526 study, evaluation,
Via Malavolti, and testing
36 • 41122 Modena for suitability.
• ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
Phone: (815) 397-6628
mail: [email protected] • www.delta-power.com Fax: (815) mail:
397-2526
[email protected] E-mail: [email protected]
• www.tecnord.com
Page MF62
FLOW CONTROLS Delta Power Company
MECHANICAL FLOW CONTROLS
4484 Boeing Drive - Rockford, IL 61109
DIMENSIONS
DIMENSIONS
ORDERING INFORMATION
ORDERING INFORMATION
DG-PDS - - -
DG-PDS – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
V0
Viton Standard OPTIONS N 3/4 NPTF Ports BODIES
Buna Standard, Screen A0 S #12 SAE Ports
Buna Standard 00 Blank Without Body
Viton Standard, Screen W0
Viton Standard V0 N 3/4 NPTF Ports
PRESSURE SETTING
Buna Standard, Screen A0 S #12 SAE Ports
Screen located at CF (1) port 0100 100 PSI
Viton Standard, Screen W0
0150 150 PSI
PRESSURE SETTING
0250 250 PSI
0100 120 PSI
Screen located at CF (1) port 0150 300 PSI
0250 250 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF63
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
FLOW CONTROLS Delta Power Company
MECHANICAL FLOW CONTROLS
4484 Boeing Drive - Rockford, IL 61109
FLOW CONTROLS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
SO-PDS STEERING PRIORITY FLOW CONTROL VALVE WITH STATIC LOAD SENSE
SO-PDS Steering Priority Flow Control Valve with Dynamic Load Sense
DESCRIPTION
DESCRIPTION
SO-PDS Steering Priority Flow Control Valve with Dynamic Load Sense
16size,
16 size, 1 5/16-12
1 5/16-12 thread,
thread, “Super”
“Super” series,
series, steering
steering priority
priority flow control
flow control valve valve withload
with static dynamic load sense.
sense.
DESCRIPTION
16OPERATION
size, 1 5/16-12 thread, “Super” series, steering priority flow control valve with dynamic load sense.
OPERATION
TheSO-PDS
The SO-PDS allows
allows priority
priority flow flow
from from
(3) to (3) to (4) regardless
(4) regardless of load pressure
of load pressure at either
at either port port(4).
(2) or port (2) or port (4).
OPERATION
Excess flow bypasses out (2).
Excess flow bypasses out (2). Port (1) is the load sense port.
The SO-PDS allows priority flow from (3) to (4) regardless of load pressure at either port (2) or port (4).
Port (1)
Excess is bypasses
flow the load sense port.
out (2).
FEATURES
Port
• (1) is the load
Hardened cagesense port.for long life.
and spool
FEATURES
• Industry common cavity.
• Hardened cage and spool for long life.
FEATURES
• Industry common cavity.
• Hardened cage and spool for long life.
• Industry common cavity.
HYDRAULIC SYMBOL VALVE SPECIFICATIONS
Max Regulated Flow 20 GPM (76 LPM)
HYDRAULIC SYMBOL VALVE SPECIFICATIONS
Rated Operating Pressure 3000 PSI (207 bar)
Max Regulated
Viscosity RangeFlow 2036GPM (76 LPM)
to 3000 SSU (3 to 647 cSt)
Rated Operating
Filtration Pressure 3000 PSI (207 bar)
ISO 18/16/13
Viscosity Range
Media Operating 36 to 3000 SSU (3 to 647 cSt)
-40° to 250° F (-40° to 120° C)
HYDRAULIC SYMBOL Temperature
Filtration
VALVE Range
SPECIFICATIONS ISO 18/16/13
Weight
Media Operating x.xx lbs. (.xx kg)
Max Regulated Flow -40°20toGPM
250°(76F (-40°
LPM) to 120° C)
Temperature
Operating Fluid Range
Media General Purpose Hydraulic Fluid
(1) (4) (2) Rated Operating Pressure 3000 PSI (207 bar)
Weight
Cartridge Torque x.xx lbs. (.xx kg)
Viscosity Range 9036ft-lbs (122SSU
to 3000 Nm) (3 to 647 cSt)
Requirements
Operating Fluid Media General Purpose Hydraulic Fluid
Filtration ISO 18/16/13
Cavity Torque
Cartridge SUPER 5WS
Media Operating Temp. Range 90 ft-lbs
-40° to(122 Nm)
250°F (-40° to 120°C)
PERFORMANCE Requirements
Cavity Form Tool (Finishing) 40500020
Weight
Cavity SUPER1.05 lbs
5WS (.48 kg)
Actual Test Data (Cartridge Only) Seal Kit 21191410
PERFORMANCE (3) Operating
Cavity Form FluidTool
Media(Finishing)
General Purpose Hydraulic Fluid
40500020
Actual Test Data (Cartridge Only) Cartridge
Seal Kit Torque Requirements 90 ft-lbs (122 Nm)
21191410
Cavity SUPER 5WS
PERFORMANCE Cavity Form Tool (Finishing) 40500020
Actual Test Data (Cartridge Only) Seal Kit 21191410
Bypass port 2 loaded, priority port 4 unloaded Priority port 4 loaded, bypass port 2 unloaded
Pressure at Port 2 (BAR) Pressure at Port 4 (BAR)
Bypass
0 port50
2 loaded, priority
100 port 4150
unloaded 200 0Priority port
504 loaded, 100
bypass port150
2 unloaded 200
20 75 20 75
Pressure at Port 2 (BAR) Pressure at Port 4 (BAR)
Regulated Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
WARNING: The
without independent specifications/application
study, evaluation, and testing for suitability.data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628
WARNING: The specifications/application data shown in our catalogs Fax: and(815) 397-2526
data sheets are intended E-mail:
only [email protected]
a general guide for the product described
(herein). Any
4484 Boeing specific
Drive application
Rockford, should
IL 61109 • USA • Phonenot
+1 be
(815)undertaken
397-6628 • Faxwithout independent
+1 (815) 397-2526 Via study,
Malavolti,evaluation, and testing
36 • 41122 Modena • ITALY •for suitability.
Phone +39 (059) 254895 • Fax +39 (059) 253512
Phone: (815) 397-6628
mail: [email protected] • www.delta-power.com Fax: (815) 397-2526
mail: [email protected]: [email protected]
• www.tecnord.com
Page MF64
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
SO-PDS – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/4 NPTF Ports
S #12 SAE Ports
PRESSURE SETTING
0120 120 PSI
0300 300 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF65
FLOW CONTROLS Delta Power Company
MECHANICAL FLOW CONTROLS
4484 Boeing Drive - Rockford, IL 61109
FLOW CONTROLS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
DG-PDD STEERING PRIORITY FLOW CONTROL VALVE WITH DYNAMIC LOAD SENSE
DG-PDD Steering Priority Flow Control Valve with Dynamic Load Sense
DESCRIPTION
DESCRIPTION
DG-PDD Steering Priority Flow Control Valve with Dynamic Load Sense
1010size,
size,7/8-14
7/8-14thread,
thread, “Delta” series, steering
“Delta” series, steeringpriority
priorityflow
flow control
control valve
valve with
with dynamic
dynamic loadload sense.
sense.
W CONTROLS DESCRIPTION Delta Power Company
OPERATION
10 size, 7/8-14 thread, “Delta” series, steering priority flow
OPERATION 4484control
Boeingvalve
Drivewith dynamic IL
- Rockford, load sense.
61109
The
TheDG-PDD
DG-PDD allows priorityflow
allows priority flowfrom
from
(2)(2) to (1)
to (1) regardless
regardless of pressure
of load load pressure at port
at either either
(1) port (1)(3).
or port or port (3).
OPERATION
Excess flow bypasses out (3).
Excess flow bypasses out (3). Port (4) is the load sense port.
PDD Steering Priority FlowThe
Control
DG-PDD Valve with
allows Dynamic
priority flow fromLoad
(2) to Sense
(1) regardless of load pressure at either port (1) or port (3).
Port (4) isflow
Excess the bypasses
load senseoutport.
(3).
DESCRIPTION
FEATURES
1 7/8-14
10 size, • thread,
Port
FEATURES
(4) is “Delta”
the load
Hardened cageseries,
sense steering
port.
and spool priority
for long life. flow control valve with dynamic load sense.
• Industry common cavity.
OPERATION
1 Hardened cage and spool for long life.
The2DG-PDDFEATURES
allows
priority common
Industry flow fromcavity.
(2) to (1) regardless of load pressure at either port (1) or port (3).
Excess flow bypasses
out (3). cage and spool for long life.
Hardened
2 Industry common cavity.
Port (4) is the load sense port.
HYDRAULIC SYMBOL VALVE SPECIFICATIONS
3
Max Regulated Flow
4 1 3 9 GPM (34 LPM)
1 FEATURESHYDRAULIC SYMBOL VALVE SPECIFICATIONS
3 Rated Operating Pressure 3000 PSI (207 bar)
4 1 3 Max Regulated Flow 369to
GPM (34 LPM)
4 Hardened cage and spool for long life. Viscosity Range 3000 SSU (3 to 647 cSt)
2 Industry common cavity.
Rated
Filtration Operating Pressure 3000 PSI
ISO 18/16/13 (207 bar)
4 Viscosity
Media OperatingRange 36 to 3000 SSU (3 to 647 cSt)
-40 to 250 F (-40 to 120 C)
HYDRAULIC SYMBOL Temperature
Filtration
VALVE Range
SPECIFICATIONS ISO 18/16/13
HYDRAULIC SYMBOL VALVE SPECIFICATIONS
Weight
Media Operating 0.38 lbs. (0.17 kg)
3 2
Max Regulated Flow
Temperature
-409 to
GPM250(34FLPM)
(-40 to 120 C)
4 1 3 Max Regulated Flow FluidRange
Operating Media9 GPM (34 General
LPM) Purpose Hydraulic Fluid
Rated Operating Pressure 3000 PSI (207 bar)
2 Weight
Cartridge
Rated Operating Torque 3000 PSI (207
Pressure 0.38
bar)lbs. (0.17 kg)
Viscosity Range 30 ft-lbs (40.6
36 to 3000Nm)
SSU (3 to 647 cSt)
Requirements
Operating Fluid Media General 647 cSt) Hydraulic Fluid
Purpose
4 Viscosity Range
Filtration 36 to 3000 SSU (3 ISOto18/16/13
Filtration Cavity
Cartridge Torque ISO 18/16/13
Media Operating Temp. Range
DELTA 4W
30 ft-lbs
-40° to(40.6
250°FNm)
(-40° to 120°C)
PERFORMANCE Media Operating
Requirements
Cavity Form Tool (Finishing) 40500002
Weight
Cavity -40 to 250 F 0.38tolbs
(-40
DELTA 4W (.17 C)
120 kg)
Actual Test Data (Cartridge Only) Temperature Seal Kit
Range 21191214
PERFORMANCE Operating
Cavity Form Fluid Tool
Media(Finishing)
General Purpose Hydraulic Fluid
2 Weight 0.38 lbs. (0.1740500002
kg)
Actual Test Data (Cartridge Only) Cartridge
Seal KitTorque Requirements 30 ft-lbs (40.6 Nm)
21191214
Operating Fluid Media General Purpose Hydraulic Fluid
Cavity DELTA 4W
PERFORMANCE Cartridge Torque
30 ft-lbs
Cavity Form Tool (Finishing) (40.6 Nm) 40500002
Requirements
Actual Test Data (Cartridge Only) Cavity Seal Kit DELTA 4W 21191214
Priority port 1 loaded, bypass port 3 unloaded Bypass port 3 loaded, priority port 1 unloaded
FORMANCE (100 PSI spring option) Cavity Form Tool (Finishing) 40500002
(100 PSI spring option)
al Test Data (Cartridge Only)Pressure at port 1 (BAR) Seal Kit
Priority port 1 loaded, bypass port 3 unloaded
21191214
Pressure at Port
Bypass port 3 loaded, 3 (BAR)
priority port 1 unloaded
0 50 (100 PSI100
spring option)
150 200 0 50 100
(100 PSI 150
spring option) 200
8 Pressure at port 1 (BAR) 30 8 Pressure at Port 3 (BAR) 30
Regulated Flow (GPM)
20 20
Priority port 1 loaded, bypass port 3 unloaded 25 Bypass port 3 loaded, priority port 1 unloaded 25
46 (100 PSI spring option) 15 4 6 (100 PSI spring option) 15
20 20
Pressure at port 1 (BAR) 10 Pressure at Port 3 (BAR) 10
0 2450 100 150 200 15 0 2 450 100 150 200 15
5 8 5
8 30 10 30
10
Regulated Flow (GPM)
02 0 02 0
25 25
6 0 500 1000 1500 2000 2500 3000 5 6 0 500 1000 1500 2000 2500 3000 5
0 Pressure at port 1 (PSI) 20 0 Pressure at Port 3 (PSI) 20
0 0
4 0 500 1000 Port
1500
2 to 1 2000 2500
15 3000 4 0 500 1000Port1500
2 to 1 2000 2500
15 3000
Pressure at port 1 (PSI) Pressure at Port 3 (PSI)
10 10
2 Port 2 to 1 2 Port 2 to 1
5 5
0 0 0 as a general guide for the product described (herein). Any specific application should0not be undertaken
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only
W 6 / 2020
0 500 independent
WARNING:
without 1000specifications/application
The study, 1500 2000
evaluation, and 2500
testing for suitability. 3000 in our catalogs and0 data sheets
data shown 500 are1000 intended1500 only as 2000a general2500 guide for the product described
3000
(herein). Any Pressure
specific application
at port 1 (PSI)should not be undertaken without independent study, evaluation, Pressureand testing
at Port for suitability.
3 (PSI)
WARNING: The Phone: (815) 397-6628 data shown in our Fax:
specifications/application catalogs(815)
and 397-2526
data sheets are intended E-mail: [email protected]
Port 2 to 1 Port 2only
to 1as a general guide for the product described
(herein). Any
4484 Boeing specific
Drive Rockford,application should
IL 61109 • USA • Phonenot be undertaken
+1 (815) 397-6628 • Faxwithout independent
+1 (815) 397-2526 study, evaluation,
Via Malavolti, and testing
36 • 41122 Modena for suitability.
• ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
Phone: (815) 397-6628
mail: [email protected] • www.delta-power.com Fax: (815) mail:
397-2526
[email protected] E-mail: [email protected]
• www.tecnord.com
Page MF66
NING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
FLOW CONTROLS Delta Power Company
MECHANICAL FLOW CONTROLS
4484 Boeing Drive - Rockford, IL 61109
DIMENSIONS
ORDERING INFORMATION
ORDERING INFORMATION
DG-PDD - - -
DG-PDS – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
V0
Viton Standard OPTIONS N 3/4 NPTF Ports BODIES
Buna Standard, Screen A0 S #12 SAE Ports
Buna Standard 00 Blank Without Body
Viton Standard, Screen W0
Viton Standard V0 N 3/4 NPTF Ports
PRESSURE SETTING
Buna Standard, Screen A0 S #12 SAE Ports
Screen located at CF (1) port 0100 100 PSI
Viton Standard, Screen W0
0150 150 PSI
PRESSURE SETTING
0250 250 PSI
0100 120 PSI
Screen located at CF (1) port 0150 300 PSI
0250 250 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF67
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
FLOW CONTROLS Delta Power Company
MECHANICAL FLOW CONTROLS
4484 Boeing Drive - Rockford, IL 61109
FLOW CONTROLS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
SO-PDD STEERING PRIORITY FLOW CONTROL VALVE WITH DYNAMIC LOAD SENSE
SO-PDS Steering Priority Flow Control Valve with Dynamic Load Sense
DESCRIPTION
DESCRIPTION
SO-PDS Steering Priority Flow Control Valve with Dynamic Load Sense
16size,
16 size, 1 5/16-12
1 5/16-12 thread,
thread, “Super”
“Super” series,
series, steering
steering priority
priority flow control
flow control valve valve with dynamic
with dynamic load sense.
load sense.
DESCRIPTION
16OPERATION
size, 1 5/16-12 thread, “Super” series, steering priority flow control valve with dynamic load sense.
OPERATION
TheSO-PDD
The SO-PDS allows
allows priority
priority flow flow
from from
(3) to (3) to (4) regardless
(4) regardless of load pressure
of load pressure at either
at either port port(4).
(2) or port (2) or port (4).
OPERATION
Excess flow bypasses out (2).
Excess flow bypasses out (2). Port (1) is the load sense port.
The SO-PDS allows priority flow from (3) to (4) regardless of load pressure at either port (2) or port (4).
Port (1)
Excess is bypasses
flow the load sense port.
out (2).
FEATURES
Port
• (1) is the load
Hardened cagesense port.for long life.
and spool
FEATURES
• Industry common cavity.
• Hardened cage and spool for long life.
FEATURES
• Industry common cavity.
• Hardened cage and spool for long life.
• Industry common cavity.
HYDRAULIC SYMBOL VALVE SPECIFICATIONS
Max Regulated Flow 20 GPM (76 LPM)
HYDRAULIC SYMBOL VALVE SPECIFICATIONS
Rated Operating Pressure 3000 PSI (207 bar)
Max Regulated
Viscosity RangeFlow 2036GPM (76 LPM)
to 3000 SSU (3 to 647 cSt)
Rated Operating
Filtration Pressure 3000 PSI (207 bar)
ISO 18/16/13
Viscosity Range
Media Operating 36 to 3000 SSU (3 to 647 cSt)
-40° to 250° F (-40° to 120° C)
HYDRAULIC SYMBOL Temperature
Filtration
VALVE Range
SPECIFICATIONS ISO 18/16/13
Weight
Media Operating x.xx lbs. (.xx kg)
Max Regulated Flow -40°20toGPM
250°(76F (-40°
LPM) to 120° C)
Temperature
Operating Fluid Range
Media General Purpose Hydraulic Fluid
(1) (4) (2) Rated Operating Pressure 3000 PSI (207 bar)
Weight
Cartridge Torque x.xx lbs. (.xx kg)
Viscosity Range 9036ft-lbs (122SSU
to 3000 Nm) (3 to 647 cSt)
Requirements
Operating Fluid Media General Purpose Hydraulic Fluid
Filtration ISO 18/16/13
Cavity Torque
Cartridge SUPER 5WS
Media Operating Temp. Range 90 ft-lbs
-40° to(122 Nm)
250°F (-40° to 120°C)
PERFORMANCE Requirements
Cavity Form Tool (Finishing) 40500020
Weight
Cavity SUPER1.05 lbs
5WS (.48 kg)
Actual Test Data (Cartridge Only) Seal Kit 21191410
(3) Operating FluidTool
Media(Finishing)
General Purpose Hydraulic Fluid
PERFORMANCE Cavity Form 40500020
Actual Test Data (Cartridge Only) Cartridge
Seal Kit Torque Requirements 90 ft-lbs (122 Nm)
21191410
Cavity SUPER 5WS
PERFORMANCE Cavity Form Tool (Finishing) 40500020
Actual Test Data (Cartridge Only) Seal Kit 21191410
Bypass port 2 loaded, priority port 4 unloaded Priority port 4 loaded, bypass port 2 unloaded
Pressure at Port 2 (BAR) Pressure at Port 4 (BAR)
Bypass
0 port50
2 loaded, priority
100 port 4150
unloaded 200 0Priority port
504 loaded, 100
bypass port150
2 unloaded 200
20 75 20 75
Pressure at Port 2 (BAR) Pressure at Port 4 (BAR)
Regulated Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
WARNING: The
without independent specifications/application
study, evaluation, and testing for suitability.data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628
WARNING: The specifications/application data shown in our catalogs Fax: and(815) 397-2526
data sheets are intended E-mail:
only [email protected]
a general guide for the product described
(herein). Any
4484 Boeing specific
Drive application
Rockford, should
IL 61109 • USA • Phonenot
+1 be
(815)undertaken
397-6628 • Faxwithout independent
+1 (815) 397-2526 Via study,
Malavolti,evaluation, and testing
36 • 41122 Modena • ITALY •for suitability.
Phone +39 (059) 254895 • Fax +39 (059) 253512
Phone: (815) 397-6628
mail: [email protected] • www.delta-power.com Fax: (815) 397-2526
mail: [email protected]: [email protected]
• www.tecnord.com
Page MF68
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
SO-PDD – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/4 NPTF Ports
S #12 SAE Ports
PRESSURE SETTING
0120 120 PSI
0300 300 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF69
MECHANICAL FLOW CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF70
MECHANICAL FLOW CONTROLS
VELOCITY FUSES
TYPICAL SCHEMATIC
Typical application for the CVF is to prevent cylinder free fall in the event of a hose or plumbing failure. The valve is usually mounted directly in the
bottom of the cylinder, and sized 1-2 GPM higher than the normal lowering speed. The valve will not re-open until pressure is bled off of port #1.
(1)
CVF
(2)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF71
MECHANICAL FLOW CONTROLS
DESCRIPTION
3/8 NPTF thread, inline velocity fuse.
OPERATION
The IM-CVF allows flow to pass between (1) and (2). When oil velocity from (1) to (2) exceeds the flow setting,
the valve shifts and blocks flow from (1) to (2).
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF72
MECHANICAL FLOW CONTROLS
DIMENSIONS
IM-CVF 11
IM-CVF 13
ORDERING INFORMATION
DE-CVF – – –
FLOW SETTINGS
11 01.0 1 PSI
13 02.0 2 PSI
03.0 3 PSI
04.0 4 PSI
05.0 5 PSI
06.0 6 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF73
MECHANICAL FLOW CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, velocity fuse valve.
OPERATION
The DE-CVF allows flow to pass from (1) to (2). When velocity exceeds the flow setting the valve shifts and blocks
flow from (1) to (2). Valve acts like a fixed orifice when passing flow from (2) to (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
250
Pressure Drop (bar)
250
Pressure Drop (bar)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF74
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-CVF – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
S #8 SAE Ports
FLOW SETTING
01.0 1 GPM
02.0 2 GPM
03.0 3 GPM
04.0 4 GPM
05.0 5 GPM
06.0 6 GPM
07.0 7 GPM
08.0 8 GPM
09.0 9 GPM
10.0 10 GPM
± 15%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF75
MECHANICAL FLOW CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF76
MECHANICAL FLOW CONTROLS
TYPICAL SCHEMATIC
Typical application for the FDA and FDH is to synchronize two independent cylinders or hydraulic motors in both directions. The FDB is a flow
divider only. It cannot be used in combine mode.
Typical application for the FDT is to provide positive traction for vehicle drive systems. If one leg loses load, the valve insures flow to the other leg.
(1) (3)
(1)( 3) (1) (3)
(2) (2)
(2)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF77
MECHANICAL FLOW CONTROLS
DESCRIPTION
10 size, 7/8-14 thread “Delta Series”, spool type, flow divider/combiner.
OPERATION
In the dividing mode, the DG-FDA will divert input flow from port (2) to ports (3) and (1), based on the ratio
specified, regardless of operating pressure. The DG-FDA will combine input flows from ports (3) and (1), to port
(2) by the same ratio. Should circuit operation result in a blockage of either (3) or (1), the opposite port may also
close under certain conditions. Should this potential exist, consult the factory.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
400
30 Pressure Drop (bar)
15
25
300 200
20
10
200 15
10 100
100 5
5
0 0 0 0
0 2 4 6 0 2 4 6 8 10 12
Flow (GPM) Flow (GPM)
3 6 9 12
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF78
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DG-FDA – – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4 NPT Ports
S #6 SAE Ports
Note: must use 4-way body
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF79
MECHANICAL FLOW CONTROLS
DESCRIPTION
16 size, 1 5/16-12 thread “Super Series,” spool-type flow divider/combiner valve.
OPERATION
In the dividing mode, the SN-FDA will divert input flow from port (2) to ports (3) and (1), based on the ratio
specified, regardless of operating pressure. The SN-FDA will combine input flows from ports (3) and (1), to port
(2) by same ratio. Should circuit operation result in a blockage of either (3) or (1), the opposite port may also close
under certain conditions. Should this potential exist, consult the factory.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Actual Test Data (Cartridge Only) Nominal Flow 40 GPM (151 LPM)
Accuracy on Flow Splits ±10% of Max Rated Inlet Flow
Flow (LPM) Maximum Operating Pressure 3500 PSI (241 bar)
0 25 50 75 100 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
300 20 Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (PSI)
15 25 30
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF80
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
SN-FDA – – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 S #12 SAE Ports
Note: must use 4-way body
SPLITS
#1 #3
25-75 25 INLET FLOW
35-65 35 15 8-15 GPM
40-60 40 25 15-25 GPM
50-50 50 30 20-30 GPM
60-40 60 40 30-40 GPM *Available as a 50-50 split only
65-35 65 All non 50-50 split valves (see chart below for flow ratings)
75-25 75
Maximum inlet flow for non 50-50 split valves
Consult factory for additional splits Model code Maximum inlet flow
15 35-65, 65-35 15.0 GPM
25 25-75, 40-60, 60-40, 75-25 25.0 GPM
30 35-65, 65-35 30.0 GPM
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF81
MECHANICAL FLOW CONTROLS
DESCRIPTION
10 size, 7/8-14 thread “Delta Series”, spool type, flow divider.
OPERATION
The DG-FDB will divert input flow from port (2) to ports (3) and (1), based on the ratio specified, regardless of
operating pressure. Should circuit operation result in a blockage of either (3) or (1), the opposite port may also
close under certain conditions. Should this potential exist, consult the factory.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
Flow (LPM) 0 10 20 (LPM)
Flow 30 40
0 5 10 Flow (LPM)15 20 400 0 10 20 30 40
600 0 5 10 15 20 400
40
20
500 600 3540
Pressure Drop (PSI)
(PSI)
300
Pressure Drop (bar)
20
500
(PSI)
300
Pressure Drop (bar)
400 15
300 2025
Drop
200
300 1520 200
Pressure
200 10
Pressure
200 1015 10
100
100 5 10 100
5
100
0 05 5
0 0
0 2 4 6
0 2 4 6 0 0
Flow (GPM) 0 0
Flow (GPM) 0 2 4 6 8 10 12
0 2 4 6 8 10 12
3 6 Flow (GPM)
3 6 Flow (GPM)
99 12
12
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF82
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DG-FDB – – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPT Ports
S #6 SAE Ports
Note: must use 4-way body
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF83
MECHANICAL FLOW CONTROLS
DESCRIPTION
“High Accuracy” 10 size, 7/8-14 thread “Delta Series”, spool type, flow divider/combiner.
OPERATION
In the dividing mode, the DG-FDH will divert input flow from port (2) to ports (3) and (1), based on the ratio
specified with a high degree of accuracy, regardless of operating pressure. The DG-FDH will combine input flows
from ports (3) and (1), to port (2) by the same ratio. Should circuit operation result in a blockage of either (3) or
(1), the opposite port may also close under certain conditions. Should this potential exist, consult the factory.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
0 10 20 (LPM)
Flow 30 40
Flow (LPM) 400 0 10 20 30 40
0 5 10 Flow (LPM)15 20 400
600 0 5 10 15 20 40 20
600 300 20
Pressure Drop (PSI)
500 3540
Pressure Drop (bar)
500 3035 15
Pressure Drop (bar)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF84
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DG-FDH – – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPT Ports
S #6 SAE Ports
Note: must use 4-way body
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF85
MECHANICAL FLOW CONTROLS
DESCRIPTION
10 size, 7/8-14 thread “Delta Series”, spool type, flow divider/combiner, positive traction valve.
OPERATION
In the dividing mode, the DG-FDT will divert input flow from port (2) to ports (3) and (1), based on the ratio
specified, regardless of operating pressure. The DG-FDT will combine input flows from ports (3) and (1). Should
circuit operation result in a blockage of either (3) or (1), the opposite port may also close under certain conditions.
Should this potential exist, consult the factory.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
500 300
Pressure Drop (PSI)
Flow (LPM) 0 10 20 30 40
Pressure Drop (bar)
9 12
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF86
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DG-FDT – – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPT Ports
S #6 SAE Ports
Note: must use 4-way body
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF87
MECHANICAL FLOW CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF88
MECHANICAL FLOW CONTROLS
LOGIC ELEMENTS
TYPICAL SCHEMATIC
Typical application for the PLA, PLB, and PLC is to provide the main stage of a high-flow capacity on/off function. A low flow solenoid valve is
generally used to provide pilot control.
The PLA and PLB are intended for flow in one direction only, whereas the PLC can be used for bi-directional operation.
The differing pilot ratios between the three valves affect pressure drop versus flow, and opening pressure versus pilot pressure.
The differing pilot ratios between the three valves affect pressure drop versus flow, and opening pressure as a function of pilot pressure.
A B
(3) (3)
(1) (1)
(2) (2)
(1) (1)
(2) (2)
(3) (3)
(1)
(2)
SL-PLC-0P-0050 (3)
P T 40 GPM
OPEN CENTER 4W3P
LOGIC CONTROL CITCUIT
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF89
MECHANICAL FLOW CONTROLS
DESCRIPTION
16 size, 1 5/16-12 thread, “Super” series, logic valve.
OPERATION
The SL-PLA with an orifice between ports (3) and (1) maintains a constant flow rate from (3) regardless of load
pressure changes in the system upstream of (3), or in the bypass leg at (2) as long as pressure at (2) is less than
(1). Used for basic blocking applications.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
100
Pressure @ Port 3 (bar)
100
Pressure @ Port 3 (bar)
0 0 0 0
0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40
Flow (GPM) Flow (GPM)
Port 3 to 2 (Undercut Cavity) Port 3 to 2 (Standard Cavity) Port 3 to 2 (Undercut Cavity) Port 3 to 2 (Standard Cavity)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF90
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
SL-PLA – – –
OPTIONS BODIES
Buna, Pilot to Close 0P Blank Without Body
Viton, Pilot to Close VP S #12 SAE Ports
Buna, Vent to Open 0V
Viton, Vent to Open VV
Buna, Pilot to Close w/seals 0B
Viton, Pilot to Close w/seals VB
Buna, Vent to Open w/seals 0C PRESSURE SETTING
Viton, Vent to Open w/seals VC 0020 20 PSI
0050 50 PSI
0100 100 PSI
0150 150 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF91
MECHANICAL FLOW CONTROLS
DESCRIPTION
16 size, 1 5/16-12 thread, “Super” series, logic valve.
OPERATION
The SL-PLB with an orifice between ports (3) and (1) maintains a constant flow rate from (3) regardless of load
pressure changes in the system upstream of (3), or in the bypass leg at (2) as long as pressure at (2) is less than
(1). Used for basic blocking applications.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
200
150 10
the area of the seat at Port (3)
150 10
100
Flow (LPM) 5 100 Flow (LPM)
50 5
0 25 50 75 100 125 150 50 0 25 50 75 100 125 150
200 250
0 0 0 0
15
Pressure @ Port 3 (PSI)
Pressure @ Port 3 (PSI)
0 5 20 25 10
200 30 15 35 40
150 Flow (GPM) Flow (GPM)
10
Port 3 to 2 (Undercut Cavity) Port 3 to 2 (Standard Cavity) Port 3 to 2 (Undercut Cavity) Port 3 to 2 (Standard Cavity)
150 10
100
5 100
50 5
50
0 0 0 0
0 5 10 20 15
25 30 35 40 0 5 10 15
20 25 30 35 40
Flow (GPM) Flow (GPM)
Port 3 to 2 (Undercut Cavity) Port 3 to 2 (Standard Cavity) Port 3 to 2 (Undercut Cavity) Port 3 to 2 (Standard Cavity)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF92
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
SL-PLB – – –
OPTIONS BODIES
Buna, Pilot to Close 0P Blank Without Body
Viton, Pilot to Close VP S #12 SAE Ports
Buna, Vent to Open 0V
Viton, Vent to Open VV
Buna, Pilot to Close w/seals 0B
Viton, Pilot to Close w/seals VB
Buna, Vent to Open w/seals 0C PRESSURE SETTING
Viton, Vent to Open w/seals VC 0020 20 PSI
0050 50 PSI
0100 100 PSI
0150 150 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF93
MECHANICAL FLOW CONTROLS
DESCRIPTION
16 size, 1 5/16-12 thread, “Super” series, logic valve.
OPERATION
The SL-PLC with an orifice between ports (3) and (1) maintains a constant flow rate from (3) regardless of load
pressure changes in the system upstream of (3), or in the bypass leg at (2) as long as pressure at (2) is less than
(1). Used for basic bidirectional blocking applications.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
75
Inlet Pressure (bar)
15 5
200
150 10 50
75
Inlet Pressure (bar)
Port 3 to 2 (Standard Cavity) Port 2 to 3 (Standard Cavity) 15 Port 3 to 2 (Undercut Cavity) Port 2 to 3 (Undercut Cavity)
5
200
150 10 50
100
5 25
50
0 0 0 0
0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40
Flow (GPM) Flow (GPM)
Port 3 to 2 (Standard Cavity) Port 2 to 3 (Standard Cavity) Port 3 to 2 (Undercut Cavity) Port 2 to 3 (Undercut Cavity)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF94
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
SL-PLC – – –
OPTIONS BODIES
Buna, Pilot to Close 0P Blank Without Body
Viton, Pilot to Close VP S #12 SAE Ports
Buna, Pilot to Close w/seals 0B
Viton, Pilot to Close w/seals VB
PRESSURE SETTING
0020 20 PSI
0050 50 PSI
0100 100 PSI
0150 150 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF95
MECHANICAL FLOW CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF96
MECHANICAL FLOW CONTROLS
HAND PUMPS
TYPICAL SCHEMATIC
Typical application for the HPA, HPB, HPC, and HPD is to supply pressure to release parking brake for towing.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF97
MECHANICAL FLOW CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, cartridge type, plunger hand pump.
OPERATION
The DE-HPA hand pump when pulled primes thru Port (1) and when pushed pressurizes outlet port (2).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF98
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-HPA – –
OPTIONS BODIES
Buna, Knob 0K Blank Without Body
Viton, Knob VK N 3/8” NPTF Ports
S #8 SAE Ports
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF99
SPECIAL APPLICATION VALVES Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
MECHANICAL FLOW CONTROLS
FEATURES
• Large displacement per stroke.
• Industry common cavity.
FEATURES
Large displacement per stroke.
Industry common cavity.
HYDRAULIC SYMBOL
HYDRAULIC SYMBOL This product is not intended as a load holding
device. Linkage is not to be removed.
36” Maximum handle length.
100
Pressure (PSI)
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
WARNING: The specifications/application data shown in our catalogs and
mail: [email protected] • www.delta-power.com
data sheets are intended only as a general guide for the product described
mail: [email protected] • www.tecnord.com
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Page MF100 Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-HPB – –
OPTIONS BODIES
Buna, Linkage 0L Blank Without Body
Viton, Linkage VL N 3/8” NPTF Ports
S #8 SAE Ports
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF101
Delta Power C
4484 Boeing Drive - Roc
FEATURES
• Large displacement per stroke.
• Industry common cavity.
FEATURES
Large displacement per stroke.
Industry common cavity.
100
Pressure (PSI)
Temperature Range
80 Weight 1.5 lbs. (.69 kg)
1000
60 Operating Fluid Media General Purpose H
40 Cartridge Torque
500 30 ft-lbs (40.6 Nm)
WARNING:
Requirements
the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
DIMENSIONS
DIMENSIONS
DIMENSIONS
ORDERING INFORMATION
ORDERING
ORDERING
INFORMATION
INFORMATION
DE-HPE – –
DE-HPEDE-HPE
- - - -
OPTIONSOPTIONS OPTIONS BODIES BODIES BODIES
Buna, Linkage 0L Linkage0L
Buna,
Buna, Linkage 0L
Blank Without Blank
WithoutWithout
Blank Body Body Body
Viton, Linkage VL LinkageVLVLN
Viton,
Viton, Linkage N NPTF
3/8NNPTF 3/8
Ports 3/8”Ports
NPTF Ports
S #8 S S SAE#8Ports
SAE Ports
#8 SAE Ports
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
WARNING: WARNING:
The specifications/application
The specifications/application
data shown
data
in shown
our catalogs
in our and
catalogs
data sheets
and dataaresheets
intended
are only
intended
as a only
general
as aguide
general
for the
guide
product
for the
Page described
product d
MF103
(herein). Any
(herein).
specific
Anyapplication
specific application
should notshould
be undertaken
not be undertaken
without independent
without independent
study, evaluation,
study, evaluation,
and testing
and
fortesting
suitability.
for suitability.
MECHANICAL FLOW CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, cartridge type, plunger hand pump.
OPERATION
The DE-HPC hand pump when pulled primes thru port (2) and when pushed provide flow pressure to outlet port
(1).
FEATURES
• Small profile.
• Industry common cavity.
• Large displacement per stroke.
2
Pump Effective Area .24 in
Force (kg)
PERFORMANCE VALVE SPECIFICATIONS
0 0 1 0 2 30 0 4 0 5 60
Actual500
Test Data (Cartridge Only) Nominal Flow .35 cu in/stroke
Pump Effective Area .24 in
2
30 Rated Operating Pressure 500 PSI (34 bar)
375 Force (kg) Typical Internal Leakage
25
Pressure (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF104
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-HPC – –
OPTIONS BODIES
Buna, Knob 0K Blank Without Body
Viton, Knob VK N 3/8” NPTF Ports
S #8 SAE Ports
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF105
SPECIAL APPLICATION VALVES Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
MECHANICAL FLOW CONTROLS
FEATURES
• Large displacement per stroke.
• Industry common cavity.
FEATURES
Large displacement per stroke.
Industry common cavity.
HYDRAULIC SYMBOL
HYDRAULIC SYMBOL This product is not intended as a load holding
device. Linkage is not to be removed.
36” Maximum handle length.
Media (150
Operating SSU) Temp. Range -40° to 250°F (-40° to 120°C)
2000 80 WeightViscosity
Range 36kg)
1.5 lbs (.69 to 3000 SSU (3 to 647 cSt)
1000
60120 Filtration
Operating Fluid Media ISO 18/16/13
General Purpose Hydraulic Fluid
1500
Pressure (BAR)
40100 Media
Cartridge TorqueOperating
Requirements 30 ft-lbs (40.6 Nm)
Pressure (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Page MF106 Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]
MECHANICAL FLOW CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-HPD – –
OPTIONS BODIES
Buna, Linkage 0L Blank Without Body
Viton, Linkage VL N 3/8” NPTF Ports
S #8 SAE Ports
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF107
Delta Power C
4484 Boeing Drive - Rock
FEATURES
• Large displacement per stroke.
• Industry common cavity.
FEATURES
Large displacement per stroke.
Industry common cavity.
100
Pressure (PSI)
Rated
Media Operating Temp. Operating
Range Pressure
-40° to 2000 PSI (207 bar)
250°F (-40° to 120°C)
Force (kg) 80
1000 Weight Typical Internal1.5Leakage
lbs (.69 kg)
0 10 20 30 40 50 60 60 0-10
Fluiddrops per min
(150
Operating Fluid Media SSU) General Purpose Hydraulic
2000 40 Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
500 Viscosity Range 36 to 3000 SSU (3 to
20 120
Cavity
Filtration DELTA 2W
ISO 18/16/13
1500
0 0 Cavity Form Tool (Finishing) 40500000
Pressure (BAR)
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF108
PECIALSPECIAL
APPLICATION
APPLICATION
VALVES VALVES Delta Power
Delta Power
Company
Com
4484 Boeing4484
DriveBoeing
- Rockford,
Drive IL
- Rockford,
61109
MECHANICAL FLOW CONTROLS
IMENSIONSDIMENSIONS
DIMENSIONS
ORDERING INFORMATION
RDERING
ORDERING
INFORMATION
INFORMATION
DE-HPF – –
DE-HPF DE-HPF
- -- -
OPTIONS OPTIONS OPTIONS BODIES BODIES
BODIES
Buna, LinkageBuna,0L Linkage
Buna, Linkage 0L
Blank
0L Without
Blank
Body Without
Blank BodyBody
Without
Viton, LinkageViton,VL
Linkage
Viton, Linkage N
VL
VL N Ports
3/8 NPTF 3/8
N NPTF Ports Ports
3/8” NPTF
S #8 SAES Ports#8
S SAE#8Ports
SAE Ports
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 6 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MF109
ARNING: The WARNING:
specifications/application
The specifications/application
data shown indata
our shown
catalogs
in and
our catalogs
data sheets
andare
dataintended
sheets are
onlyintended
as a general
only as
guide
a general
for the guide
product
fordescribed
the product
erein). Any (herein).
specific application
Any specific
should
application
not beshould
undertaken
not bewithout
undertaken
independent
without study,
independent
evaluation,
study,
and
evaluation,
testing forand
suitability.
testing for suitability.
MECHANICAL PRESSURE CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP1
MECHANICAL PRESSURE CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP2
MECHANICAL PRESSURE CONTROLS
DIRECT ACTING RELIEF VALVES GPM PSI LPM BAR CAVITY MODEL PAGE
DIFFERENTIAL AREA RELIEF VALVES GPM PSI LPM BAR CAVITY MODEL PAGE
TYPICAL SCHEMATIC
Typical application for the RVA, RVD, RWA, RWD is to protect pump and system.
Typical application for the RCA and RCD is cross over relief to protect motor in both directions, where lowest possible price is desired.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP3
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, direct acting relief valve.
OPERATION
The DE-RCA blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the poppet to open and
allow metered flow from (2) to (1). The cartridge offers smooth transition in response to load changes in common
hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
0 5 10 15 20 25 30 35 40 45 50 55 60
4500 300
4000
3500 250
PERFORMANCE VALVE SPECIFICATIONS
Pressure Drop (PSI)
3000 200
Actual
2500 Test Data (Cartridge Only) Nominal Flow 12 GPM (45 LPM)
150
2000 Rated Operating Pressure 3500 PSI (241 bar)
1500 Flow (LPM) 100 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
1000 0 5 10 15 20 25 30 35 40 45 50 55 60
50 Filtration ISO 18/16/13
5004500
300 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
04000 0
0
3500 2 4 6 8 10 12 14 16 250 Weight .38 lbs (.17 kg)
Pressure Drop (PSI)
3000 Flow (GPM) Operating Fluid Media General Purpose Hydraulic Fluid
200
2500 2500 3500 Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
150
2000 Cavity DELTA 2W
1500 100 Cavity Form Tool (Finishing) 40500000
1000
50 Seal Kit 21191200
500
0 0
0 2 4 6 8 10 12 14 16
Flow (GPM)
2500 3500
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP4
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-RCA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
S #8 SAE Ports
PRESSURE RANGE/SETTING
2500 100 - 2500 PSI
3500 250 - 3500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP5
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
7 size, 5/8-18 thread, “Mini” series, direct acting relief valve.
OPERATION
The MA-RVA blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the poppet to open and
allow metered flow from (2) to (1). The cartridge offers smooth transition in response to load changes in common
hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Actual Test Data (Cartridge Only) Nominal Flow 5 GPM (19 LPM)
Rated Operating Pressure 3000 PSI (207 bar)
Flow (LPM)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 5 10 15 20 25 30 Filtration ISO 18/16/13
4000 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
3500 250 Weight .39 lbs (.17 kg)
3000 Operating Fluid Media General Purpose Hydraulic Fluid
Pressure Drop (PSI)
200
2500 Cartridge Torque Requirements 15 ft-lbs (20.3 Nm)
150
2000 Cavity MINI 2W
1500 100 Cavity Form Tool (Finishing) 40500003
1000 Seal Kit 21191000
50
500
0 0
0 2 4 6 8
Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP6
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
MA-RVA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
PRESSURE RANGE
0500 100 - 500 PSI
1500 500 - 1500 PSI
3000 1500 - 3000 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP7
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, direct acting relief valve.
OPERATION
The PB-RVA blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the poppet to open and
allow metered flow from (2) to (1). The cartridge offers smooth transition in response to load changes in common
hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Pressure at port (1) must not exceed 2500 PSI.
Actual Test Data (Cartridge Only) Nominal Flow 6 GPM (23 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Flow (LPM) Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 5 10 15 20 25 30 35 Filtration ISO 18/16/13
4500 300 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
4000
250 Weight .30 lbs (.14 kg)
3500
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP8
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
PB-RVA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
PRESSURE RANGE/SETTING
0800 100 - 800 PSI
2000 800 - 2000 PSI
3500 2000 - 3500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP9
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, direct acting relief valve.
OPERATION
The DE-RVA blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the poppet to open and
allow metered flow from (2) to (1). The cartridge offers smooth transition in response to load changes in common
hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 5 10 15 20 25 30 35 40 45
4500 300
4000
250
Pressure Drop (BAR)
3500
Pressure Drop (PSI)
3000
PERFORMANCE 200 VALVE SPECIFICATIONS
2500
Actual 150
2000Test Data (Cartridge Only) Nominal Flow 4 GPM (15.6 LPM) 4000 PSI
1500 100 8 GPM (30 LPM) 3000 PSI
Flow (LPM)
1000 Rated Operating Pressure 4000 PSI (276 bar)
0 5 10 15 20 25 30 35 40 50 45
500
4500 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 0 300
4000
0 2 4 6 8 10 12
Filtration ISO 18/16/13
250
Pressure Drop (BAR)
Flow (GPM)
3000
Port 2 to 1 Port 2 to 1 Port 2 to 1
200 Weight .56 lbs (.25 kg)
2500
150 Operating Fluid Media General Purpose Hydraulic Fluid
2000
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
1500 100
1000 Cavity DELTA 2W
50
500 Cavity Form Tool (Finishing) 40500000
0 0 Seal Kit 21191200
0 2 4 6 8 10 12
Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP10
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-RVA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Knob 0K S #8 SAE Ports
Viton, Knob VK
PRESSURE RANGE/SETTING
1500 200 - 1500 PSI
3000 1500 - 3000 PSI
4000 2500 - 4000 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP11
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, direct acting relief valve.
OPERATION
The PB-RWA blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the poppet to open and
allow metered flow from (2) to (1). The cartridge offers smooth transition in response to load changes in common
hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Pressure at port (1) must not exceed 2500 PSI.
Actual Test Data (Cartridge Only) Nominal Flow 6 GPM (23 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Flow (LPM) Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 5 10 15 20 25 30 35 Filtration ISO 18/16/13
4500 300 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
4000
250
Weight .31 lbs (.14 kg)
3500
Pressure Drop (PSI)
Port 2 to 1 Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP12
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
PB-RWA – – –
OPTIONS BODIES
External Adj. W/Locknut Buna 00 Blank Without Body
External Adj. W/Locknut Viton V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
Internal Adjust Buna 0I
Internal Adjust Viton VI
Tamper Proof Buna 0T PRESSURE RANGE/SETTING
Tamper Proof Viton VT Ext./Int. Adjustment
1000 100 - 1000 PSI
3500 500 - 3500 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP13
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, direct acting relief valve.
OPERATION
The DE-RWA blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the poppet to open and
allow metered flow from (2) to (1). The cartridge offers smooth transition in response to load changes in common
hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
For critical leakage applications consult factory.
Flow (LPM)
0 5 10 15 20 25 30 35 40 45
4000
3500 250
Pressure Drop (PSI)
3000 200
2500
PERFORMANCE VALVE SPECIFICATIONS
150
2000
Actual Test Data (Cartridge Only)
1500
Nominal Flow 8 GPM (30 LPM)
100
Rated Operating Pressure 4000 PSI (276 bar)
1000 Flow (LPM)
50 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
500 0 5 10 15 20 25 30 35 40 45
4000 Filtration ISO 18/16/13
0 0
3500
0 2 4 6 8 10 12 250 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .51 lbs (.23 kg)
Pressure Drop (PSI)
Flow (GPM)
Pressure Drop (bar)
3000 200
2500 Port 2 to 1 Port 2 to 1 Operating Fluid Media General Purpose Hydraulic Fluid
150
2000 Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
1500 100 Cavity DELTA 2W
1000 Cavity Form Tool (Finishing) 40500000
50
500 Seal Kit 21191200
0 0
0 2 4 6 8 10 12
Flow (GPM)
Port 2 to 1 Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP14
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-RWA – – –
OPTIONS BODIES
Buna, External Adj. W/Locknut 00 Blank Without Body
Viton, External Adj. W/Locknut V0 N 3/8” NPTF Ports
Buna, Knob 0K S #8 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T PRESSURE RANGE/SETTING
Viton, Tamper Proof VT Ext./Int. Adjustment
0500 100 - 500 PSI
3000 100 - 3000 PSI
4000 3000 - 4000 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP15
PRESSURE CONTROLS Delta Power Company
MECHANICAL PRESSURE CONTROLS
4484 Boeing Drive - Rockford, IL 61109
DE-RWF Direct
DE-RWF DIRECT ACTING
Acting RELIEF
Relief ValveVALVE
– Fast–Response
FAST RESPONSE
DESCRIPTION
DESCRIPTION
PRESSURE CONTROLS
10 size, 7/8-14 thread, “Delta” series, direct acting relief valve
10 size, 7/8-14 thread, “Delta” series, direct acting relief valve. Delta Power Company
OPERATION 4484 Boeing Drive - Rockford, IL 61109
The DE-RWF blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the poppet to open
OPERATION
and allow metered flow from (2) to (1).
The DE-RWF blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the poppet to open and
DE-RWF Direct Acting Relief Valve – Fast Response
allow
The metered
cartridge flow
offers from (2)
smooth to (1). The
transition cartridgetooffers
in response smooth transition
load changes in common in hydraulic
responsecircuits.
to load changes in common
DESCRIPTION
hydraulic circuits.
10 size, 7/8-14 thread, “Delta” series, direct acting relief valve
FEATURES
FEATURES
OPERATION
Hardened parts for long life.
The• DE-RWF
Hardened parts
blocks
Industry for from
flow
common long life.
(2) to (1) until sufficient pressure is present at (2) to force the poppet to open
cavity.
and• allow metered
Industry flow from
common (2) to (1).
cavity.
The cartridge offers smooth transition in response to load changes in common hydraulic circuits.
FEATURES
Hardened parts for long life.
HYDRAULIC SYMBOL Industry common cavity.
Fast response direct acting poppet style relief valve.
HYDRAULIC SYMBOL For critical leakage applications consult factory.
Fast response direct acting poppet style relief valve.
For critical leakage applications consult factory.
PERFORMANCE
HYDRAULIC SYMBOL
Actual Test Data (Cartridge Only) VALVE SPECIFICATIONS
Flow (LPM) Nominal Flow 20 GPM (75 LPM)
0 15 30 45 60 75 Rated Operating Pressure 4000 PSI (276 bar)
4000 Fast response direct acting poppet
Viscosity Range 36 style
to 3000 relief
SSUvalve.
(3 to 647 cSt)
250 For critical leakage applications consult
Filtration factory.
ISO 18/16/13
3500
Media Operating
-40 to 250 F (-40 to 120 C)
Pressure Drop (BAR)
3000
Pressure Drop (PSI)
3000
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
WARNING:
mail: [email protected] • www.delta-power.com
The specifications/application data shown in our catalogs and data sheets are intended only
mail: [email protected] • www.tecnord.com
as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Page MP16 Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]
PRESSURE CONTROLS Delta Power Compan
MECHANICAL PRESSURE CONTROLS
4484 Boeing Drive - Rockford, IL 611
DIMENSIONS
ORDERING INFORMATION
ORDERING INFORMATION
DE-RWFDE-RWF
- – - –- –
OPTIONS BODIES
External Adjust w/Locknut, Buna 00
OPTIONS Blank Without Body BODIES
External Adjust w/Locknut,
Buna, External V0
Viton Adj. W/Locknut 00 N 3/8 NPTF Ports
Blank Without Body
Knob,
Viton, External 0K
Buna Adj. W/Locknut V0 S #8 SAE Ports N 3/8” NPTF Ports
Knob, Viton Buna, VK Knob 0K S #8 SAE Ports
Internal Adjust, Buna 0I Knob
Viton, VK
Internal Adjust, Viton VI Adjust
Buna, Internal 0I
Tamper Proof, Buna 0T Adjust
Viton, Internal VI PRESSURE RANGE
Tamper Proof, Viton VT Proof
Buna, Tamper 0T0500 100 – 500 PSI
PRESSURE RANGE/SETTING
Viton, Tamper Proof VT3000 500 – 3000 Ext./Int.
PSI Adjustment
4000 2000 0500
– 4000100
PSI
- 500 PSI
3000 500 - 3000 PSI
Tamper 4000Proof
2000 - 4000 PSI
Fill In 4 Digit Pressure Setting
Example: 2500 = 2500
Tamper ProofPSI
Fill in 4 Digit Pressure Setting
Example: 2500 - 2500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP17
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, differential area relief valve.
OPERATION
The DE-RCD blocks flow from (1) to (2) until sufficient pressure is present at (1) to force the poppet to open and
allow metered flow from (1) to (2). The cartridge offers smooth transition in response to load changes in common
hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
0 5 10 15 20 25 30 35 40 45 50 55 60
4000
3500 250
3000
Pressure Drop (PSI)
200
Pressure Drop (bar)
200
Pressure Drop (bar)
2500 3500
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP18
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-RCD – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8 NPTF Ports
S #8 SAE Ports
PRESSURE RANGE/SETTING
2500 100 - 2500 PSI
3500 250 - 3500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP19
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, differential area relief valve.
OPERATION
The PB-RVD blocks flow from (1) to (2) until sufficient pressure is present at (1) to force the poppet to open and
allow metered flow from (1) to (2). The cartridge offers smooth transition in response to load changes in common
hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Pressure at port (2) must not exceed 2500 PSI.
Actual Test Data (Cartridge Only) Nominal Flow 8 GPM (30 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Flow (LPM) Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 5 10 15 20 25 30 35
Filtration ISO 18/16/13
4000
3500 250 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressu re Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP20
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
PB-RVD – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
PRESSURE RANGE/SETTING
0800 100 - 800 PSI
2000 800 - 2000 PSI
3500 2000 - 3500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP21
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, differential area relief valve.
OPERATION
The DE-RVD blocks flow from (1) to (2) until sufficient pressure is present at (1) to force the poppet to open and
allow metered flow from (1) to (2). The cartridge offers smooth transition in response to load changes in common
hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
PERFORMANCE
1500 100 Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
500
Cavity DELTA 2W
Actual
1000
Test Data (Cartridge Only)
50 Cavity0 Form Tool (Finishing) 40500000 0
500
Seal Kit0 2 4 6 8 0 1
21191200 2 1 4 1 16
Flow (GPM)
0 0
0 2 4 6 8 0 1 2 1 4 1 16 P o rt 1 to 2 P o r t 1 to 2
Flow (GPM)
P o rt 1 to 2 Flow
P o r(LPM)
t 1 to 2 Flow (LPM)
0 5 10 15 20 25 30 35 40 45 50 55 60 0 5 10 15 20 25 30 35 40 45 50 55 60
Flow (LPM)
2000 4500 300
0 5 10 15 20 25 30 35 40 45 50 55 60
4500
4000
300 250
Pressure Drop (PSI)
3500
Pressure Drop (bar)
200
3000 200 2500
1000
2500 150
150 2000
2000 50
1500 1500 100
500 100
1000 1000
50 50
500 500
0 0 0 0 0 0
0 0 22 44 6 6 8 8 10 1
02 1 1 42 1 16 4 1 16 0 2 4 6 8 10 12 14 16
Flow (GPM)
Flow (GPM) Flow (GPM)
P o rt 1 to 2 P o rt 1 to 2
P o rt 1 to 2 P o r t 1 to 2
P o rt 1 to 2 P o rt 1 to 2
Flow (LPM)
0 5 10 15 20 25 30 35 40 45 50 55 60
4500 300
4000
3500 250
Pressure Drop (PSI)
3000 200
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
2500
without independent study, evaluation, and testing for suitability.
150
2000
1500 100
1000
50
5 0 0 Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
4484 Boeing Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
0
mail: [email protected] • www.delta-power.com 0 mail: [email protected] • www.tecnord.com
0 2 4 6 8 10 12 14 16
Flow (GPM)
Page MP22
P o rt 1 to 2 P o rt 1 to 2
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-RVD – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Screen A0 S #8 SAE Ports
Viton, Screen W0
Buna, Knob 0K
Viton, Knob VK
Buna, Knob, Screen AK PRESSURE RANGE/SETTING
Viton, Knob, Screen WK 0200 50 - 200 PSI
1500 200 - 1500 PSI
Note: use screen only if flow direction 3000 1500 - 3000 PSI
is from (1) to (2). 4000 2500 - 4000 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP23
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, differential area relief valve.
OPERATION
The HE-RVD blocks flow from (1) to (2) until sufficient pressure is present at (1) to force the poppet to open and
allow metered flow from (1) to (2). The cartridge offers smooth transition in response to load changes in common
hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
0 10 20 30 40 50 60 70 80 90 100 110 120 130
4500 310
PERFORMANCE 4000 VALVE SPECIFICATIONS
260
3500
Actual Test Data (Cartridge Only) Nominal Flow210
40 GPM (151 LPM)
Pressure (PSI)
Pressure (bar)
500
Pressure (bar)
3000
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
2500 0 160 -40
Cavity DELTA 2W
2000 0 5 10 15 20 110 25 30 35
Cavity Form Tool (Finishing) 40500000
1500 Flow (GPM)60 Seal Kit 21191200
1000
500 Port 1 to 2 Tank 10Port 1 to 2
0 -40
0 5 10 15 20 25 30 35
Flow (GPM)
Port 1 to 2 Tank Port 1 to 2
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP24
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
HE-RVD – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Screen A0 S #8 SAE Ports
Viton, Screen W0
Buna, Knob 0K
Viton, Knob VK
Buna, Knob, Screen AK PRESSURE RANGE/SETTING
Viton, Knob, Screen WK 5000 1000 - 5000 PSI
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP25
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, differential area relief valve.
OPERATION
The PB-RWD blocks flow from (1) to (2) until sufficient pressure is present at (1) to force the poppet to open and
allow metered flow from (1) to (2). The cartridge offers smooth transition in response to load changes in common
hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Pressure at port (2) must not exceed 2500 PSI.
Actual Test Data (Cartridge Only) Nominal Flow 8 GPM (30 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Flow (LPM)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 5 10 15 20 25 30 35
Filtration ISO 18/16/13
4000
250 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
3500
Weight .32 lbs (.15 kg)
Pressure Drop (PSI)
3000
Pressure Drop (bar)
Port 1 to 2 Port 1 to 2
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP26
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
PB-RWD – – –
OPTIONS BODIES
External Adj. W/Locknut Buna 00 Blank Without Body
External Adj. W/Locknut Viton V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
Internal Adjust Buna 0I
Internal Adjust Viton VI
Tamper Proof Buna 0T PRESSURE RANGE/SETTING
Tamper Proof Viton VT Ext./Int. Adjustable
1000 100 - 1000 PSI
3500 500 - 3500 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP27
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, differential area relief valve.
OPERATION
The DE-RWD blocks flow from (1) to (2) until sufficient pressure is present at (1) to force the poppet to open and
allow metered flow from (1) to (2).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 5 10 15 20 25 30 35 40 45 50 55 60
4500 300
4000
PERFORMANCE
3500 250 VALVE SPECIFICATIONS
Pressure Drop (PSI)
0 2 4 6 8 10 12 14 16
3000 200
Flow (GPM) Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
2500
150 Cavity DELTA 2W
2000 Port 1 to 2 Port 1 to 2 Port 1 to 2
Cavity Form Tool (Finishing) 40500000
1500 100
1000
Seal Kit 21191200
50
500
0 0
0 2 4 6 8 10 12 14 16
Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP28
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-RWD – – –
OPTIONS BODIES
Buna, External Adj. W/Locknut 00 Blank Without Body
Viton, External Adj. W/Locknut V0 N 3/8” NPTF Ports
Buna, Knob 0K S #8 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T PRESSURE RANGE/SETTING
Viton, Tamper Proof VT Ext./Int. Adjustable
1000 100 - 1000 PSI
3000 100 - 3000 PSI
4000 3000 - 4000 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
Note: aluminum NOT durability rated for
4000 PSI. Consult factory for options.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP29
MECHANICAL PRESSURE CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP30
MECHANICAL PRESSURE CONTROLS
TYPICAL SCHEMATIC
Typical application for the RVP and RWP is to protect pump or system. Typical application for the RWR and RVR, is to be used as counterbalance
in a system where positive hydraulic locking is not required. In this schematic positive locking is done by using a P. O. check valve.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP31
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pilot operated relief valve.
OPERATION
The DE-RVP blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the pilot stage open,
allowing the main stage to shift, opening (2) to (1). The cartridge offers smooth transition in response to load
changes in common hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 25 50 75
3000 200
PERFORMANCE
2500 VALVE SPECIFICATIONS
Pressure Drop (PSI)
150
Actual
2000 Test Data (Cartridge Only) Nominal Flow 20 GPM (76 LPM)
1500
Rated Operating Pressure 4000 PSI (276 bar)
100
Flow (LPM) Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
1000 0 25 50 75
50
Filtration ISO 18/16/13
3000 200
500 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
2500 Weight .56 lbs (.25 kg)
0 0
Pressure Drop (PSI)
150
0
2000 5 10 15 20 Operating Fluid Media General Purpose Hydraulic Fluid
Flow (GPM) Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
1500 100
Port 2 to 1 Port 2 to 1 Cavity DELTA 2W
1000
50
Cavity Form Tool (Finishing) 40500000
500 Seal Kit 21191200
0 0
0 5 10 15 20
Flow (GPM)
Port 2 to 1 Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP32
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-RVP – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Knob 0K S #8 SAE Ports
Viton, Knob VK
PRESSURE RANGE/SETTING
4000 100 - 4000 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP33
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
12 size, 1 1/16-12 thread, “Tecnord” series, pilot operated relief valve.
OPERATION
The HT-RVP blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the pilot stage off its seat,
allowing the main stage spool to shift, opening (2) to (1). The cartridge offers smooth transition in response to
load changes in common hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Pressure (bar)
Pressure (PSI)
Pressure (bar)
30000 5 10 15 20 25
Pressure (bar)
Pressure (PSI)
Pressure (bar)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP34
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
HT-RVP – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 S #12 SAE Ports
Buna, Knob 0K
Viton, Knob VK
PRESSURE SETTING
5000 100 - 5000 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP35
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pilot operated relief valve with reverse flow.
OPERATION
The DE-RVR blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the pilot stage open,
allowing the main stage to shift, opening (2) to (1). The relief flow path is from (2) to (1). Free reverse flow, from
(1) to (2), occurs when the pressure at (1) is at least 10 PSI (.7 bar) higher than at port (2).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Consult Chart for flow capacity port (1) to (2).
Flow (LPM)
0 5 10 15 20 25 30 35 40 45 50 55 60
4500 300
4000
PERFORMANCE 250
VALVE SPECIFICATIONS
3500
Pressure Drop (PSI)
Actual
3000 Test Data (Cartridge Only) 200 Nominal Flow 15 GPM (57 LPM)
2500 Rated Operating Pressure 4000 PSI (276 bar)
Flow (LPM) 150
2000 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
1500 0 5 10 15 20 25 30 35 40 45 50 55 100
60
Filtration ISO 18/16/13
1000 4500 300
50 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
500 4000
250 Weight .56 lbs (.25 kg)
0 3500
Pressure Drop (PSI)
0
Pressure Drop (bar)
3000
0 2 4 6 8 0 1 2 1 4 1 16 200 Operating Fluid Media General Purpose Hydraulic Fluid
2500 Flow (GPM) Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
150
2000
Port 2 to 1 Port 2 to 1 Port 1 to 2 Cavity DELTA 2W
1500 100
Cavity Form Tool (Finishing) 40500000
1000
500
50 Seal Kit 21191200
0 0
0 2 4 6 8 0 1 2 1 4 1 16
Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP36
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-RVR – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Knob 0K S #8 SAE Ports
Viton, Knob VK
PRESSURE RANGE/SETTING
4000 100 - 4000 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP37
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
16 size, 1 5/16-12 thread, “Super” series, pilot operated relief valve with reverse flow.
OPERATION
The SJ-RVR blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the pilot stage off its seat,
allowing the main stage spool to shift, opening (2) to (1). The relief flow path is from (2) to (1). Reverse flow, from
(1) to (2), occurs when the pressure at (1) is at least 30 PSI (2.1 bar) higher then at port (2). The Cartridge offers
smooth transition in response to load changes in common hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
2500
1500 100 150
2000
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP38
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
SJ-RVR – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/4” NPTF Ports
Buna, Knob 0K S #12 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T PRESSURE SETTING
Viton, Tamper Proof VT 3500 500 - 3500 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP39
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pilot operated relief valve.
OPERATION
The DE-RWP blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the pilot stage open,
allowing the main stage to shift, opening (2) to (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 25 50 75
3000
PERFORMANCE 200 VALVE SPECIFICATIONS
2500
Actual Test Data (Cartridge Only) Nominal Flow 15 GPM (57 LPM)
Pressure Drop (PSI)
150
2000 Rated Operating Pressure 4000 PSI (276 bar)
Flow (LPM) Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
1500 100
0 25 50 75
Filtration ISO 18/16/13
10003000 200 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
50
5002500 Weight .53 lbs (.24 kg)
Pressure Drop (PSI)
0 0
0 5 10 15 20
Flow (GPM)
Port 2 to 1 Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP40
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-RWP – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Knob 0K S #8 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T PRESSURE RANGE/SETTING
Viton, Tamper Proof VT 4000 1000 - 4000 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP41
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
High Pressure, High Flow, Rapid Response, 10 size, 7/8-14 thread, “Delta” series, pilot operated relief valve.
OPERATION
The HE-RWP blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the pilot stage open,
allowing the main stage to shift, opening (2) to (1).
FEATURES
• High pressure valve.
• Hardened parts for long life.
• Industry common cavity.
• Rapid response to sudden pressure application.
• Excellent regulation of pressure with flow (low override).
300
4000
240 Rated Operating Pressure 5000 PSI (345 bar)
3000 HERWP/Pressure drop vs flow
180 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
2000 Flow (LPM)
120 Filtration ISO 18/16/13
1000
0 37 74 111 148
60 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
5000
Pressure Drop (PSI)
0 0
4000 0
300 Weight .53 lbs (.24 kg)
10 20 30 40
240 Operating Fluid Media General Purpose Hydraulic Fluid
3000 Flow (GPM)
180 Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
2000 HERWP at 4000 PSI HERWP at 2000 PSI
120 Cavity DELTA 2W
1000 60 Cavity Form Tool (Finishing) 40500000
0 0 Seal Kit 21191200
0 10 20 30 40
Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP42
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
HE-RWP – – –
OPTIONS BODIES
Buna Standard 00 Consult Factory
Viton Standard V0
Buna, Knob 0K
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T PRESSURE RANGE/SETTING
Viton, Tamper Proof VT 5000 1000 - 5000 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 1500 - 1500 PSI
WARNING
DO NOT USE ALUMINUM BODY
HIGH PRESSURE (5000 PSI) PRODUCT
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP43
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pilot operated relief valve with reverse flow.
OPERATION
The DE-RWR blocks flow from (2) to (1) until sufficient pressure is present at (2) to force the pilot stage open, and
allow metered flow from (2) to (1). The relief flow path is from (2) to (1). Free reverse flow, from (1) to (2), occurs
when the pressure at (1) is at least 10 PSI (.7 bar) higher than at port (2).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Consult chart for flow capacity (1) to (2).
Standard Body
Flow (LPM)
0 25 50 75
3000 200
PERFORMANCE
2500 VALVE SPECIFICATIONS
Pressure Drop (PSI)
150
2000
Actual Test Data (Cartridge Only) Nominal Flow 15 GPM (57 LPM)
1500 100
Rated Operating Pressure 4000 PSI (276 bar)
Standard Body
1000
Flow (LPM) 50 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
500
0 25 50 75 Filtration ISO 18/16/13
0
3000 0 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
200
0 5 10 15 20
2500 Weight .53 lbs (.24 kg)
Pressure Drop (PSI)
Flow (GPM)
150 Operating Fluid Media General Purpose Hydraulic Fluid
2000 Port 2 to 1 Port 2 to 1 Port 1 to 2
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
1500 100
Cavity DELTA 2W
1000
50 Cavity Form Tool (Finishing) 40500000
500 Seal Kit 21191200
0 0
0 5 10 15 20
Flow (GPM)
Port 2 to 1 Port 2 to 1 Port 1 to 2
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP44
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-RWR – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Knob 0K S #8 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T PRESSURE RANGE/SETTING
Viton, Tamper Proof VT 4000 1000 - 4000 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP45
MECHANICAL PRESSURE CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP46
MECHANICAL PRESSURE CONTROLS
TYPICAL SCHEMATIC
Typical application for the RVC is in a series circuit where a load on motor #2 causes back pressure on motor #1 and relief valve #1. Vent in port
(2) of RV 1 allows spring to maintain proper load on motor #1 even though back pressure is present. Port (2) pressure into spring chamber to offset
back pressure. Vent at port (2) causes .2 GPM flow from port (2) to port (1).
Typical application for the RVB is in a parallel circuit where the load on motor #2 does not cause back pressure on motor #1. Relief valve maintains
differential pressure across motor because one side of motor always goes to tank.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP47
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, crossover relief valve for parallel circuit applications.
OPERATION
The DE-RVB is a direct-acting, cross over relief valve. When pressure at either port exceeds the nominal setting
value, flow will be diverted to the opposite port. Back pressure at either port will affect the nominal setting of the
opposite port on a 1:1 basis. For correlation purposes, pre-set value will be measured at port (2). Pressure at port
(1) will not vary more than ±300 PSI from the port (2) value. The cartridge offers smooth transition in response to
load changes in common hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
0 5 10 15 20 25 30 35 40 45 50 55 60
4500
300
PERFORMANCE
4000 VALVE SPECIFICATIONS
3500 250
Pressure Drop (PSI)
Actual Test Data (Cartridge Only) Nominal Flow 15 GPM (57 LPM) from (2) to (1)
3000 200
20 GPM (76 LPM) from (1) to (2)
2500
Flow (LPM) 150 Rated Operating Pressure 4000 PSI (276 bar)
2000
0 5 10 15 20 25 30 35 40 45 50 55 60 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
1500 100
4500
1000
300 Filtration ISO 18/16/13
4000 50
500 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
3500 250
Pressure Drop (PSI)
0 0
3000 200
0 2 4 6 8 10 12 14 16 Operating Fluid Media General Purpose Hydraulic Fluid
2500 Flow (GPM) Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
150
2000
Port 1 to 2 Port 1 to 2 Port 1 to 2 Cavity DELTA 2W
1500 100 Cavity Form Tool (Finishing) 40500000
1000 Seal Kit 21191202
50
500
0 0
0 2 4 6 8 10 12 14 16
Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP48
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-RVB – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Knob 0K S #8 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T PRESSURE RANGE/SETTING
Viton, Tamper Proof VT Ext./Int. Adjustable
0700 100 - 700 PSI
1800 500 - 1800 PSI
4000 1000 - 4000 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP49
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, crossover relief valve for series circuit application.
OPERATION
The DE-RVC is a direct-acting, cross over relief valve. When pressure at either port exceeds the nominal setting
value, flow will be diverted to the opposite port. Back pressure at either port will affect the nominal setting of the
opposite port on a 1:1 basis. For correlation purposes, pre-set value will be measured at port (2). Pressure at port
(1) will not vary more than ±300 PSI from the port (2) value. The cartridge offers smooth transition in response to
load changes in common hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
0 5 10 15 20 25 30 35 40 45 50 55 60
4500
300
4000
250
PERFORMANCE
3500 VALVE SPECIFICATIONS
Pressure Drop (PSI)
3000 200
Actual
2500 Test Data (Cartridge Only) Nominal Flow 15 GPM (57 LPM) from (2) to (1)
150
2000 20 GPM (76 LPM) from (1) to (2)
1500 Flow (LPM)
100 Rated Operating Pressure 4000 PSI (276 bar)
1000 0 5 10 15 20 25 30 35 40 45 50 55 60
4500 50 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
500 300
4000
0 0
Filtration ISO 18/16/13
250
35000 2 4 6 8 10 12 14 16 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP50
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-RVC – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Knob 0K S #8 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T PRESSURE RANGE/SETTING
Viton, Tamper Proof VT Ext./Int. Adjustable
0700 100 - 700 PSI
1800 500 - 1800 PSI
4000 1000 - 4000 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP51
MECHANICAL PRESSURE CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP52
MECHANICAL PRESSURE CONTROLS
TYPICAL SCHEMATIC
These very flexible pressure compensator valves can regulate flow through many types of orifices: Electro-Proportional Orifices, Plate or Set
Screw Orifices, Needle Valves &/or even across the pressure drop of other control valve (s). When using multiple compensating devices in the
same circuit it is good practice to keep at least 50 PSID between their settings to reduce the likelihood of cross talking during dynamic events.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP53
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pressure compensating regulator valve.
OPERATION
The DF-PCR-0P with an orifice between ports (3) and (1) maintains a constant flow rate from (3) regardless of
load pressure changes in the system upstream of (3), or in the bypass leg at (2) as long as pressure at (2) is less
than (1). The valve’s spool maintains a constant differential pressure across an external orifice, thereby regulating
the hydraulic flow rate from (3) to (2) (see options table for pressure ranges). When used with an orifice as
described above, as a priority type regulator, delivering pump flow first to (3), then bypassing excess to (2). All
ports may be fully pressurized. The DF-PCR-0V with a dump valve and a pilot relief valve at (1) acts as main
stage of a ventable relief valve.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
0 5 10 15 20 25 30 35
250
15
PERFORMANCE VALVE SPECIFICATIONS
Pressure @ Port 3 (PSI) Pressure @ Port 3 (PSI)
200
Actual
150
Test Data (Cartridge Only) Nominal Flow 10 GPM (38 LPM)
10
Rated Operating Pressure 3500 PSI (241 bar)
Flow (LPM)
100 Seat Ratio Area of Pilot is equal to the area
0 5 10 15 20 25 30 35
5 at Port (3)
250
50
15
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Pressure @ Port 3 (bar)
200
0 0 Filtration ISO 18/16/13
0 2 4 6 8 10 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
150 Flow (GPM) 10 Weight .19 lbs (.09 kg)
Port 3 to 2 Port 3 to 2 Operating Fluid Media General Purpose Hydraulic Fluid
100
5 Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
50 Cavity DELTA 3W
Cavity Form Tool (Finishing) 40500001
0 0
Seal Kit 21191206
0 2 4 6 8 10
Flow (GPM)
Port 3 to 2 Port 3 to 2
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP54
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DF-PCR – – –
OPTIONS BODIES
Buna, Pilot to Close 0P Blank Without Body
Viton, Pilot to Close VP N 1/4” NPTF Ports
Buna, Vent to Open 0V S #6 SAE Ports
Viton, Vent to Open VV
PRESSURE SETTING
0040 40 PSI
0080 80 PSI
0150 150 PSI
0200 200 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP55
MECHANICAL PRESSURE CONTROLS
QC-CP3 PRESSURE COMPENSATING VALVE, BYPASS TYPE FOR 3 WAY FLOW CONTROL
DESCRIPTION
Special cavity, pressure compensating valve, bypass type, for 3 way flow control, normally closed.
OPERATION
The QC-CP3 with an orifice between ports (3) and (1) maintains a constant flow rate from (3) regardless of load
pressure changes in the system upstream of (3), or in the bypass leg at (2) as long as pressure at (2) is less than
(1). The valve’s spool maintains a constant differential pressure across an external orifice, thereby regulating the
hydraulic flow rate from (3) to (2), (see options table for pressure ranges). When used with an orifice as described
above, as a priority type regulator, delivering pump flow first to (3), then bypassing excess to (2). All ports may
be fully pressurized.
FEATURES
• Hardened parts for long life.
• Spring range from 8 to 24 bar.
30
Actual Test Data (Cartridge Only) Nominal Flow 33 GPM (120 LPM)
20 018
Rated Operating Pressure 3500 PSI (241 bar)
15
Pressure (bar) vs. flow (lt/min) Typical Internal Leakage 014
For various pressure compensator settings (150 SSU) 35 ml/min @ 250 bar
30 10 Viscosity Range 008 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
25 5 023
@ Port 3 (bar)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP56
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
QC-CP3 – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/2” BSP Ports
S #8 SAE Ports
PRESSURE SETTINGS
008 8 bar (115 PSI) @ 60 l/min
014 14 bar (200 PSI) @ 60 l/min
018 18 bar (260 PSI) @ 60 l/min
023 23 bar (330 PSI) @ 60 l/min
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP57
PRESSURE CONTROLS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
MECHANICAL PRESSURE CONTROLS
PRESSURE CONTROLS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
PP-PCA Fixed
PP-PCA FIXED Pressure
PRESSURE Compensating Regulator
COMPENSATING Valve VALVE
REGULATOR
PRESSURE CONTROLSDESCRIPTION
PP-PCA Fixed8DESCRIPTION
Pressure
size, 3/4-16 Compensating Regulator
thread, “Power” series, Valve
pressure compensating
Delta Power Company
regulator valve.
4484 Boeing Drive - Rockford, IL 61109
OPERATION DESCRIPTION
8 size, 3/4-16 thread, “Power” series, pressure compensating regulator valve.
8 size, 3/4-16
The PP-PCA-0P with anthread,
orifice “Power”
betweenseries, pressure
ports (3) and (1)compensating regulatorflow
maintains a constant valve.
rate from (3) regardless
PP-PCA Fixed Pressure
of Compensating
load Regulator
pressure changes
OPERATION Valve
in the system upstream of (3), or in the bypass leg at (2) as long as pressure at
(2) lessOPERATION
TheisPP-PCA-0P
DESCRIPTION than (1).with an orifice between ports (3) and (1) maintains a constant flow rate from (3) regardless of
The PP-PCA-0P with an orifice between ports (3) and (1) maintains a constant flow rate from (3) regardless
8 load
size, pressure
3/4-16 thread,
of spool
loadchanges“Power”
pressure in theseries,
system pressure
upstream compensating
of upstream
(3), or in theregulatoror valve.
bypass inleg
theatbypass
(2) as long as(2)
pressure
as longatas(2)pressure
is less at
The valves maintainschanges
a constant in the system
differential of (3),
pressure across an external orifice,leg at
thereby regulating the
than (1). (2)
hydraulic flow israte
lessacross
than (1). this external orifice. (see options table for pressure ranges)
OPERATION
TheThe valves spool
PP-PCA-0P withmaintains
an orifice abetween
constantportsdifferential
and pressure
(3) differential
(1) maintainsacross an external
a constant flow orifice,
rate from thereby regulating the
(3) thereby
regardless
Thewith valves spool maintains a constant pressure across an external orifice, regulating the
ofWhen used
hydraulic
load pressureflow rate
hydraulic
anacross
orifice
changes
flow in
rate
as
this
thedescribed
external
system
across this
above,(see
orifice.
upstream
external
it functions
of options
(3),
orifice. or
(see
as
in a priority
table
the for
bypass
options table
type
pressure
leg
for
regulator,
atranges).
(2)
pressure as delivering
When
long
ranges) asused pump
with flow
pressure an
at orifice
first
(2) to thethanexternal orifice, then bypassing excess to (2). All ports may be fully pressurized.
asisdescribed
less (1).
above, it functions as a priority type regulator, delivering pump flow first to the external orifice, then
1 bypassing Whenexcessusedto with
(2). an ports
All orificemayasand
described
beafully above, it functions as aas priority
withtype regulator, delivering
pilotpump
reliefflow
The
The PP-PCA-0V
valves spool with a dump
maintains valve
a constant pilotpressurized.
differential relief
pressurevalve The PP-PCA-0V
at (1) acts main a dump
stage of valve and arelief
a regulating
ventable
valve.
valve at first
(1) to the
acts as external
main orifice,
stage of a then bypassing
ventable relief excessacross
valve. to (2). an
All external
ports may orifice, thereby
be fully pressurized. the
hydraulic flow rate across this external orifice. (see options table for pressure ranges)
1
2 The PP-PCA-0V with a dump valve and a pilot relief valve at (1) acts as main stage of a ventable relief
FEATURES
FEATURES
valve. When used with an orifice as described above, it functions as a priority type regulator, delivering pump flow
first the Hardened parts then
for long life.
• toHardened
external
Industry
orifice,
parts for long
common
bypassing
life.
cavity.
excess to (2). All ports may be fully pressurized.
1 2
• PP-PCA-0V FEATURES
Industry common
3 The with a cavity.
dumpparts
Hardened valvefor and a life.
long pilot relief valve at (1) acts as main stage of a ventable relief
valve. Industry common cavity. Can be used as a logic element.
2 3 FEATURES
HYDRAULIC SYMBOL
PP-PCA-0P is commonly used as a bypass flow regulator
HYDRAULIC SYMBOL Hardened parts for long life.
(80 PSI recommended).
Industry common cavity. Can be used as a logicPP-PCA-0V element.
is commonly used as the main stage of a
1 1 ventable relief valve (40 and 80 PSI recommended).
3
HYDRAULIC SYMBOL PP-PCA-0P is commonly used as a bypass flow regulator (80 PSI
3 2 3 1 2 recommended).
1 Can be used as a logic element.
PP-PCA-0V is commonly used as the main stage of a ventable
PP-PCA-0P is commonly used as a bypass flow regulator (80 PSI
HYDRAULICPCA-0P
SYMBOL 2 PCA-0V relief valve (40 and 80 PSI recommended).
3 3 2 recommended).
Can be usedPP-PCA-0V
as a logiciselement.
commonly used as the main stage of a ventable
1 1
PERFORMANCE PCA-0P PCA-0V PP-PCA-0P relief valve (40 and
is commonly 80as
used PSI recommended).
a bypass flow regulator (80 PSI
Actual
3 Test Data2 (Cartridge
3 Only) 2 VALVE
recommended). SPECIFICATIONS
PP-PCA-0VNominal Flow
is commonly 8 GPM
used as the main(30 LPM)
stage of a ventable
PERFORMANCE
Rated
relief valve (40Operating
and 80 Pressure
PSI 3500 PSI (241 bar)
recommended).
PCA-0P
Actual Test Data FlowPCA-0V
(LPM) Only)
(Cartridge VALVE SPECIFICATIONS Area of Pilot is equal to the area at
Seat Ratio Nominal Flow Port (3) 8 GPM (30 LPM)
0
PERFORMANCE 10 20 30 VALVE SPECIFICATIONS
250 Rated Operating Pressure 3500
PERFORMANCE Flow (LPM) 16 Viscosity Range 36 to 3000 SSUPSI (3 to(241
647bar)
cSt)
Actual Test Data (Cartridge Only) Nominal Flow 8 GPM
Area of (30
PilotLPM)
is equal to the area at
Pressure @ Port 3 (BAR)
Actual200
Test Data (Cartridge Only) Filtration
VALVE SPECIFICATIONS ISO 18/16/13
Pressure @ Port 3 (PSI)
0 10 20 30 Seat Ratio
250 Rated
Media Operating Pressure
Operating Port
3500(3) PSI (241 bar)
12 Nominal Flow 8 -40
GPMto(30 250LPM)F (-40 to 120
16Temperature
Seat Viscosity
Ratio Range Range 36 to 3000 SSU (3 C)
to 647 cSt)
150 Rated Operating Pressure 3500 PSI (241 bar)Pilot is equal to the area
Area of
Pressure @ Port 3 (BAR)
200 Weight
.19 lbs.
Area (.08
of Pilot kg)
atisPort (3) to the area at
equal
0 10 20 30 8 Seat Ratio Media Operating
100 12Operating
Viscosity Fluid
Range Media
General
Port (3) Purpose
-40
36 toto3000Hydraulic
250 SSU (3 Fluid
F (-40toto 120
647 cSt)C)
250 150 Temperature
CartridgeRangeTorque Range
16 Viscosity
Filtration 36 to 3000
25 ft-lbs (34 SSU
ISONm) (3 to
18/16/13 647 cSt)
4 Weight .19 lbs. (.08 kg)
Pressure @ Port 3 (BAR)
50 Requirements
Filtration
8 ISO 18/16/13
Pressure @ Port 3 (PSI)
without independent
WARNING: The study, evaluation, and testing for suitability.
specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP58
PRESSURE CONTROLS Delta Power Company
MECHANICAL PRESSURE CONTROLS
4484 Boeing Drive - Rockford, IL 61109
DIMENSIONS
DIMENSIONS
1.13
[28.6]
.87 [22.2]
1.25
HEX. [31.8]
.63
[15.9]
.25 [6.3]
.58
.22 [5.5] [14.8]
1.17
2.82 [29.7]
[71.6]
3/4-16 UNF-2A 2.25
[57.2] 2.50
THREAD [63.5]
1.61
[41.0]
#6 SAE PORT
(3X)
ORDERING INFORMATION
ORDERING INFORMATION
PP-PCA - - -
PP-PCA – – –
OPTIONS BODIES
Buna, Vent to Open 0V Blank Without Body
Buna, Pilot to Close OPTIONS
0P N 1/4 NPTF Ports BODIES
Viton, Vent to Buna, to Open 0V
Open Vent VV S #6 SAE Blank
Ports Without Body
to Close 0P
Buna, Pilot VP
Viton, Pilot to Close N 1/4” NPTF Ports
Viton, Vent to Open VV PRESSURE SETTING S #6 SAE Ports
Viton, Pilot to Close VP
0040 40 PSI
0080 80 PSI
0150 150 PSI
0200 200 PSIPRESSURE SETTING
0040 40 PSI
0080 80 PSI
0150 150 PSI
0200 200 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP59
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
12 size, 1 1/16-12 thread, “Tecnord” series, pressure compensating regulator valve.
OPERATION
The TR-PCA-0P with an orifice between ports (3) and (1) maintains a constant flow rate from (3) regardless of
load pressure changes in the system upstream of (3), or in the bypass leg at (2) as long as pressure at (2) is less
than (1). The valve’s spool maintains a constant differential pressure across an external orifice, thereby regulating
the hydraulic flow rate across this external orifice (see options table for pressure ranges). When used with an
orifice as described above, it functions as a priority type regulator, delivering pump flow first to the external orifice,
then bypassing excess to (2). All ports may be fully pressurized. The TR-PCA-0V with a dump valve and a pilot
relief valve at (1) acts as main stage of a ventable relief valve.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow ( LPM)
PERFORMANCE
0 25 50 75 100 125 150 VALVE SPECIFICATIONS
350
Actual Test Data (Cartridge Only) Nominal Flow 40 GPM (151 LPM)
300 20 Rated Operating Pressure 3500 PSI (241 bar)
Pressure @ Port 3 (BAR)
3 (PSI) @ Port 3 (PSI)
20
Pressure @ Port 3 (BAR)
100
Filtration ISO 18/16/13
250 5 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
50 15
200 Weight .54 lbs (.24 kg)
0 0
150 0 Operating Fluid Media General Purpose Hydraulic Fluid
5 10 15 20 25 30 35 40 10
Flow (GPM) Cartridge Torque Requirements 70 ft-lbs (95 Nm)
100
Port 3 to 2 Port 3 to 2 5 Cavity TECNORD 3WS
50
Cavity Form Tool (Finishing) 40500033
0 0 Seal Kit 21191306
0 5 10 15 20 25 30 35 40
Flow (GPM)
Port 3 to 2 Port 3 to 2
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP60
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
TR-PCA – – –
OPTIONS BODIES
Buna, Pilot to Close 0P Blank Without Body
Viton, Pilot to Close VP S #10 SAE Ports
Buna, Vent to Open 0V
Viton, Vent to Open VV
Δ P SETTING
@ 1 GPM with Pilot Vented
0020 20 PSI
0050 50 PSI
0090 90 PSI
0150 150 PSI
0230 230 PSI
±10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP61
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
16 size, 1 5/16-12 thread, “Super” series, pressure compensating regulator valve.
OPERATION
The SL-PCA-0P with an external orifice between ports (3) and (1) maintains a constant flow rate across the
external orifice, regardless of load pressure changes in the system upstream of (3), or in the bypass leg at
(2) as long as pressure at (2) is less than (1). The valve’s spool maintains a constant differential pressure
across the external orifice, thereby regulating the hydraulic flow rate across the external orifice (see options
table for pressure ranges). When used with an orifice as described above, it functions as a priority type regulator,
delivering pump flow first to the external orifice, then bypassing excess to (2). All ports may be fully pressurized.
The SL-PCA-0V with a dump valve and a pilot relief valve at (1) acts as main stage of a ventable relief valve.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
20
250 0 25 50 75 100 125 150
15 Filtration
350 ISO 18/16/13
200
Media300Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure @ Port 3 (PSI)
350 25
Pressure @ Port 3 (PSI)
300
Pressure @ Port 3 (PSI)
100 20
300 20
250 5
50
15 250
200 0 0 15
200
150 0 5 10 15 20 25 30 35 40 10
Flow (GPM) 150 10
100
Port 3 to 2 (Undercut Cavity) Port 3 to 2 (Standard Cavity) 5 100
50 5
50
0 0
0 0
0 5 10 15 20 25 30 35 40
Flow (GPM) 0 5 10 15 20 25 30 35 40
Flow (GPM)
Port 3 to 2 (Undercut Cavity) Port 3 to 2 (Standard Cavity)
Port 3 to 2 (Undercut Cavity) Port 3 to 2 (Standard Cavity)
Flow (LPM)
0 25 50 75 100 125 150
400
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
300 20
250
15
200
4484 Boeing
150 Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815)
10 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected]
100 • www.delta-power.com mail: [email protected] • www.tecnord.com
5
50
Page MP62
0 0
0 5 10 15 20 25 30 35 40
Flow (GPM)
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
SL-PCA – – –
OPTIONS BODIES
Buna, Pilot to Close 0P Blank Without Body
Viton, Pilot to Close VP S #12 SAE Ports
Buna, Vent to Open 0V
Viton, Vent to Open VV
Buna, Pilot to Close with Seals 0B
Viton, Pilot to Close with Seals VB
Buna, Vent to Open with Seals 0C Δ P SETTING
Viton, Vent to Open with Seals VC @ 1 GPM with Pilot Vented
0020 20 PSI
0050 50 PSI
0100 100 PSI
0150 150 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP63
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pressure compensating valve, restrictive type with bypass.
OPERATION
The DG-PCB allows pressure compensated or proportional flow from (1) to (2) regulated by the pressure
differential across (1) and (4) with a bypass of (4) to (3). The spring chamber is constantly connected at (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Regulated Flow @
Regulated Flow @
Regulated Flow @
Port 2 (GPM)
25
Port 2 (GPM)
25
Port 2 (LPM)
Port 2 (LPM)
6 6
20
10 Operating
20
Fluid Media General Purpose Hydraulic Fluid
2
4 4 15
5 Cartridge
15 Torque Requirements 30 ft-lbs (40.6 Nm)
10
2 2 Cavity
10 DELTA 4W
0 5 0 5
Cavity Form Tool (Finishing) 40500002
0 500 0
1000 1500
0 2000 25000 3000 0
0 500 1000 0 1500 5002000 10002500 15003000 2000 2500 Seal
3000 Kit 21191214
PressurePressure
@ Port 2 (PSI)
@ Port 2 (PSI) Pressure @ Port 2 (PSI)
.110" dia. orifice .156" dia. orifice
.110" dia. orifice .156" dia. orifice
.110" dia. orifice .156" dia. orifice
Priority port (2) load: 1500-1700 psi, .156” dia orifice, 15 gpm supply Priority port (2) load: 1500-1700 PSI, .110” dia orifice, 10 GPM supply
not intended for differential pressure > 1500 psi port (4) to port (3) not intended for differential pressure > 1500 PSI port (4) to port (3)
Pressure @ Port 3 (bar) Pressure @ Port 3 (bar) Pressure @ Port 3 (bar) Pressure @ Port 3 (bar)
0 50 0 100 50 150 100 200 150 0 200 50 100
0 150
50 200
100 150 200
10 10 10 10
35 35 35 35
8 Pressure @8 Port 3 (bar) 30 8 30 8 Pressure @ Port 330(bar)
30
Flow (GPM)
Flow (GPM)
Flow (GPM)
Flow (GPM)
Flow (LPM)
Flow (LPM)
Flow (LPM)
Flow (LPM)
25 25 25 25
6 6 6 6
0 4
50 4
100 20
15
150 200 4
20
15 4 0 50
20
15 100
20
15
150 200
0 2 2
10
2
10 10
2
10 10
5 35 5 5 5 35
0 0 0 0 0 0 0 0
8 0 500 1000 0 1500 500 2000 10002500 15003000 2000 30 1000 81500
0 2000
500 2500 0
2500
1000 2000 500
2500
3000 3000
1500 3000 30
Flow (GPM)
Flow (LPM)
Pressure @ Port 3 (PSI) Pressure @ Port 3 (PSI) 25 Pressure @ Port 3 (PSI) Pressure @ Port 3 (PSI) 25
6 6
Port 2 flow Port 3 flow Port 2 flow Port 3 flow 20 Port 2 flow Port 3 flow Port 2 flow Port 3 flow 20
4 WARNING: the specifications/application data shown in our catalogs and data sheets are intended only15 4
as a general guide for the product described (herein). Any specific application should not be undertaken 15
W 19 / 2020
DIMENSIONS
ORDERING INFORMATION
DG-PCB – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
PRESSURE DIFFERENTIAL
0150 150 PSI
0250 250 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP65
MECHANICAL PRESSURE CONTROLS
DESCRIPTION 0 50
Pressure @ Port 2 (BAR)
100 150 200
10
10 size, 7/8-14 thread, “Delta” series, pressure compensating 35 valve, restrictive type with bypass.
8
30
Regulated Flow @
Regulated Flow @
Port 2 (GPM)
Port 2 (LPM)
6 25
OPERATION 4
20
15
FEATURES
• Hardened parts for longer life.
Priority port 2 load: 1500 - 1700 PSI, .156" dia orifice, 15 GPM supply Priority port 2 load: 1500 - 1700 PSI, .110" dia orifice, 10 GPM supply
not intended for differential pressure > 1500 PSI port 4 to port 3 not intended for differential pressure > 1500 PSI port 4 to port 3
Flow (LPM)
Flow (GPM)
Flow (LPM)
25 25
6 6
20 20
4 15 4 15
2
10
5
2 Bypass line (3) can be pressurized. 10
5
0 0 0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Regulated Flow @
3 2 Filtration ISO 18/16/13
Port 2 (GPM)
Port 2 (LPM)
25
Media6 Operating Temp. Range -40° to 250°F (-40° to 120°C)
20
PERFORMANCE Weight
4
.38 lbs (.17 kg)
15
Operating Fluid Media General Purpose Hydraulic Fluid
Actual Test Data (Cartridge Only) 2
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
10
5
Cavity DELTA 4W
0 0
Cavity Tools
0 Kit 500 1000 1500 2000 2500 3000
(form tool, reamer, tap) 40500002
Pressure @ Port 2 (PSI)
Seal Kit .110" dia. orifice 21191214
.156" dia. orifice
10 GPM supply flow, .110” orifice, 150 PSI spring - 15 GPM supply flow, Priority port 2 load: 1500 - 1700 PSI, .156” dia orifice, 15 GPM supply
10 GPM supply flow, .110" orifice, 150 PSI spring 15
- GPM supply flow, .156" orifice, 150 PSI spring1500
- PSI load on port 3 Priority port 2 load: 1500 - 1700 PSI, .156" dia orifice, 15 GPM supply
.156” orifice, 150 PSI spring - 1500 PSI load on port 3 notintended
not intendedfor
fordifferential
differentialpressure
pressure>>1500
1500PSI
PSIport
port44totoport
port33
Pressure
Pressure@
@Port
Port 22 (BAR)
(bar) Pressure @@
Pressure Port
Port3 3(BAR)
(bar)
0 50 100 150 200 0 50 100 150 200
10
10
@(GPM)
35 35
8 8 30
(GPM)
(LPM)
30
Regulated Flow @
Flow(GPM)
Flow(LPM)
25
Port 2
6
Port 2 (GPM)
Port 2 (LPM)
Flow @Flow
6 25 20
4 15
Flow
Flow
20
Regulated
4 10
15 2
5
0 0
Regulated
2 10
5 0 500 1000 1500 2000 2500 3000
0 0 Pressure @ Port 3 (PSI)
Pressure @ Port 3 (PSI)
0 500 1000 1500 2000 2500 3000
Port Port
─ 2 flow Port
2 flow ─ Port
3 3flow
flow
Pressure
Pressure @ Port 22 (PSI)
(PSI)
.110" dia.dia.
─ .110” orifice
orifice ─.156"
.156”dia.
dia.orifice
orifice
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
without independentPriority
study, port 2 load: 1500
evaluation, - 1700 PSI,
and testing .156" dia orifice, 15 GPM supply
for suitability. Priority port 2 load: 1500 - 1700 PSI, .110" dia orifice, 10 GPM supply
not intended for differential pressure > 1500 PSI port 4 to port 3 not intended for differential pressure > 1500 PSI port 4 to port 3
low (LPM)
low (GPM)
low (LPM)
Page MP66 25 25
6 6
20 20
4 15 4 15
Regul
Po
DIMENSIONS
Priority port 2 load: 1500 - 1700 PSI, .110” dia orifice, 10 GPM supply
Priority port 2 for
not intended load: 1500 - 1700
differential PSI, .110"
pressure dia PSI
> 1500 orifice,
port104 GPM supply
to port 3
not intended for differential pressure > 1500 PSI port 4 to port 3
Pressure
Pressure@
@Port
Port 33 (BAR)
(bar)
Flow (GPM)
(LPM)
Flow (GPM)
Flow (LPM)
5 6
25
0 20
5 4 15
Flow
0 10
2
5
0 0
0 500 1000 1500 2000 2500 3000
ORDERING INFORMATION
DG-TCB – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” BSP Ports
S #6 SAE Ports
PRESSURE SETTINGS
014 14 bar (200 PSI)
020 20 bar (285 PSI)
032 32 bar (460 PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP67
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, pressure compensating regulator valve (restrictive type).
OPERATION
The PP-PCC-00 with an external orifice beyond port (3) and sensed by port (1) maintains a constant flow rate
from (3) regardless of load pressure changes in the system downstream of (3), or in the inlet at (2) as long
as pressure at (3) is above (1) by more then spring setting chosen and pump supply is in excess of demand.
The valve’s spool maintains a constant differential pressure across an external orifice, thereby regulating the
hydraulic flow rate across this external orifice (see options table for pressure ranges). When used with an orifice
as described above, it functions as a restrictive type regulator, delivering pump flow through the external orifice.
All ports may be fully pressurized.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
28
7
6 24 Ratio Area of Pilot is equal to the area
Regulated Flow vs Inlet Pressure 20
5 at Port (3)
4 Inlet Pressure (bar) 16
3 12 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 34 68 102 136 170 204
2 8
91 Filtration ISO 18/16/13
4 32
80 0 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Regulated Flow (GPM)
28
7 0 500 1000 1500 2000 2500 3000 Weight .25 lbs (.11 kg)
6 24
5
Inlet Pressure (PSI) 20 Operating Fluid Media General Purpose Hydraulic Fluid
4 2 GPM 4 GPM 6 GPM 8 GPM 16 Cartridge Torque Requirements 25 ft-lbs (34 Nm)
3 12
Cavity POWER 3W
2 8
1 4 Cavity Form Tool (Finishing) 40500024
0 0 Seal Kit 21191111
0 500 1000 1500 2000 2500 3000
Inlet Pressure (PSI)
2 GPM 4 GPM 6 GPM 8 GPM
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP68
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
PP-PCC – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 S #6 SAE Ports
*Urethane, Standard U0
Buna, Screen A0
Viton, Screen W0
Urethane, Screen Y0
Δ P SETTING
*Urethane seals are recommended 0100 100 PSI
when inlet pressures exceed 1500 PSI 0220 220 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP69
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, 2 ways pressure compensating/reducing valve.
OPERATION
The DF-CP2 allows pressure compensated flow from (2) to (3) regulated by the pressure present at (1). Pressure
differential between (3) and (1) is fixed at 8/14/18 bar (according to the pressure settings). These are minimum
values, increasing with the flow because of the pressure drop through the valve (see graph).When used with (1)
connected to a drain line, it works as pressure reducing valve.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
• Spring range 8 to 18 bar. Pressure compensator for 2 way flow control,
typically used with an external orifice inline with
port (3). Port (1) should sense upstream pressure
of orifice.
Pressure Drop (bar) vs. Flow (lt/min) DF-CP2 008 - Flow (lt/min) vs. inlet pressure (bar)
For various pressure compensator settings (bar) For various orifice diameters (mm)
Control orifice Dia (mm)
Pressure drop (bar)
Flow (lt/min)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP70
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
Inlet pressure (bar) (for bodies style and sizes see section “Accessories”)
ORDERING INFORMATION
DF-CP2 – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” BSP Ports
S #6 SAE Ports
PRESSURE SETTINGS
008 8 bar (115 PSI)
014 14 bar (200 PSI)
018 18 bar (260 PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP71
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
Special cavity, 2 ways pressure compensating/reducing valve.
OPERATION
The QC-CP2 allows pressure compensated flow from (2) to (3) regulated by the pressure present at (1).
Pressure differential between (3) and (1) is fixed at 8/14/18/24 bar (according to the pressure settings). These
are minimum values, increasing with the flow because of the pressure drop through the valve (see graph). When
used with (1) connected to a drain line, it works as a fix setting pressure reducing valve.
FEATURES
• Hardened parts for long life.
• Spring range 8 to 24 bar.
Pressure compensator for 2 way flow control,
typically used with an external orifice inline with
port (3). Port (1) should sense upstream pressure
of orifice.
Flow (lt/min)
Port 2 to 3
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP72
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
QC-CP2 – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/2” BSP Ports
S #8 SAE Ports
PRESSURE SETTINGS
008 8 bar (115 PSI)
014 14 bar (200 PSI)
018 18 bar (260 PSI)
024 24 bar (340 PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP73
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
12 size, 1 1/16-12 thread, “Tecnord” series, pressure compensating regulator valve (restrictive type).
OPERATION
The TR-PCC with an external orifice beyond port (3) and sensed by port (1) maintains a constant flow rate from
(3) regardless of load pressure changes in the system downstream of (3), or in the inlet at (2) as long as pressure
at (3) is greater than (1) by more than spring setting chosen and pump supply is in excess of demand. The valve’s
spool maintains a constant differential pressure across an external orifice, thereby regulating the hydraulic flow
rate across this external orifice (see table for pressure ranges). When used with an orifice as described above,
it functions as a restrictive type regulator, delivering pump flow through the external orifice. All ports may be fully
pressurized.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
16
Actual Test Data (Cartridge Only) 50 Nominal Flow 20 GPM (76 LPM)
12
Rated Operating Pressure 3500 PSI (241 bar)
Regulated Flow vs Load Pressure at Port 1
8 Seat Ratio Area of Pilot is equal to the area
Load Pressure at Port 1 (BAR) 25 at Port (3)
0 4 34 68 102 136 170 204 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
20 75 Filtration ISO 18/16/13
0 0
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Regulated Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP74
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
TR-PCC – – –
OPTIONS BODIES
Buna 0P Blank Without Body
Viton VP S #10 SAE Ports
Δ P SETTING
@ 1 GPM with Pilot Vented
0080 80 PSI
0150 150 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP75
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, spring adjustable pressure compensating valve, bypass type.
OPERATION
The DF-PCE with an external orifice in parallel with ports (3) and (1) maintains a constant flow rate across the
external orifice, regardless of load pressure changes in the system upstream of (3), or in the bypass leg at (2)
as long as pressure at (2) is greater than (1). The valve’s spool maintains a constant differential pressure across
an external orifice, thereby regulating the hydraulic flow rate across this external orifice (see table for pressure
ranges). When used with an orifice as described above, it functions as a bypass type regulator, delivering pump
flow through the external orifice.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP76
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DF-PCE – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T
Viton, Tamper Proof VT PRESSURE RANGE
0300 100 - 300 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0200 - 200 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP77
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
16 size, 1 5/16-12 thread, “Super” series, pressure compensating regulator valve.
OPERATION
The SL-PCE with an external orifice in parallel with ports (3) and (1) maintains a constant flow rate across
the external orifice, regardless of load pressure changes in the system upstream of (3), or in the bypass leg
at (2) as long as pressure at (2) is less than (1). The valve’s spool maintains a constant differential pressure
across the external orifice, thereby regulating the hydraulic flow rate across the external orifice (see options
table for pressure ranges). When used with an orifice as described above, it functions as a priority type regulator,
delivering pump flow first to the external orifice, then bypassing excess to (2). All ports may be fully pressurized.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
PERFORMANCE
0 10 20 30 40 50 60 70 80 90 100 110 VALVE SPECIFICATIONS
350 24
Actual300
Test Data (Cartridge Only) 21 Nominal Flow 40 GPM (151 LPM)
18 Rated Operating Pressure 3500 PSI (241 bar)
Pressure Drop (PSI)
250
Pressure drop (bar)
Flow (LPM)
15 Seat Ratio Area of Pilot is equal to the area
200 0 10 20 30 40 50 60 70 80 90 100 110
350 12 24 at Port (3)
150
9 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
300 21
100
6
18 Filtration ISO 18/16/13
Pressure Drop (PSI)
250
Pressure drop (bar)
50 3
15 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
200
0 0
0 5 10 15 20 25 30 12 Weight 1.15 lbs (.52 kg)
150
Flow (GPM) 9 Operating Fluid Media General Purpose Hydraulic Fluid
100 Cartridge Torque Requirements 90 ft-lbs (122 Nm)
Port 3 to 2 Port 3 to 2 Port 3 to 2 6
50 3 Cavity SUPER 3WS
0 0 Cavity Form Tool (Finishing) 40500021
0 5 10 15 20 25 30 Seal Kit 21191406
Flow (GPM)
Port 3 to 2 Port 3 to 2 Port 3 to 2
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP78
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
SL-PCE – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 S #12 SAE Ports
Buna, Knob 0K
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T
Viton, Tamper Proof VT PRESSURE RANGE/SETTING
0300 50 - 300 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0200 - 200 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP79
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pressure compensating valve, restrictive type.
OPERATION
The DF-PCS allows pressure compensated flow from (1) to (2) regulated by the pressure present at (3). The
spring chamber is constantly vented at (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Flow (LPM)
6
Actual Test Data (Cartridge Only) 20 Nominal Flow 10 GPM (38 LPM)
4 15 Rated Operating Pressure 3500 PSI (241 bar)
Pressure @ Port 2 (bar) 10 Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per path
2 0 50 100 150 200
5 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
10
0 0 35 Filtration ISO 18/16/13
0 500 1000 1500 2000 2500 3000 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
8 30
Pressure @ Port 2 (PSI)
25 Weight .35 lbs (.16 kg)
Flow (GPM)
Flow (LPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP80
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DF-PCS – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
PRESSURE DIFFERENTIAL
0150 150 PSI
0450 450 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP81
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pressure compensating valve, restrictive type.
OPERATION
The DF-TCS allows pressure compensated flow from (1) to (2) regulated the pressure present at (3). Pressure
differential between (1) and (3) is fixed at 8/24 bar (according to the pressure settings). These are minimum
values increasing with the flow because of the pressure drop through the valve (see graph).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Pressure Drop (bar) vs. Flow (lt/min) DF-TCS 008 - Flow (lt/min) vs. inlet pressure (bar)
For various pressure compensator settings (bar) For various orifice diameters (mm)
Control orifice Dia (mm)
Pressure drop (bar)
Flow (lt/min)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP82
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DF-TCS – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” BSP Ports
S #6 SAE Ports
PRESSURE SETTINGS
008 8 bar (115 PSI)
024 24 bar (340 PSI)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP83
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pressure compensating valve, restrictive type.
OPERATION
The DF-PCT with an external orifice in front of port (1) allows pressure compensated flow from (1) to (2), regulated
by the pressure present at (3). The spring chamber is constantly vented at (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Can be used as an adjustable logic element. For
fixed version see DF-PCS. For higher spring
differential pressure ranges consult factory.
28
PERFORMANCE 7
24
VALVE SPECIFICATIONS
6
5 20
Actual Test Data (Cartridge Only) 4 16 Nominal Flow 10 GPM (38 LPM)
3 12
2 8 Rated Operating Pressure 3500 PSI (241 bar)
4
1
300 PSI setting, Regulated Flow vs Inlet Pressure Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per path
0 0
0 500 1000 Inlet
1500Pressure
2000 (bar)
2500 3000 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Inlet Pressure (PSI)
0 34 68 102 136 170 204 Filtration ISO 18/16/13
4 GPM 8 GPM
9 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
32
8
Regulated Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP84
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DF-PCT – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T
Viton, Tamper Proof VT PRESSURE RANGE
0300 50 - 300 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0200 - 200 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP85
MECHANICAL PRESSURE CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP86
MECHANICAL PRESSURE CONTROLS
TYPICAL SCHEMATIC
Typical application for the PRP and PWP is multi-system pressure setting. System relief pressure must be greater then reduce pressure setting.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP87
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pilot operated, pressure reducing, relieving valve.
OPERATION
The DF-PRP in its steady state, allows flow to pass from (2) to (3), with the spring chamber constantly drained
at (1). When a pre-determined pressure is reached at (3), the spool shifts to restrict input flow at (2), thereby
reducing (restricting) flow. If valve and pressure at port (3) exceeds setting, spool shift to open passage at port
(1), thereby regulating pressure at port (3) by relieving excess flow. The cartridge offers smooth transition in
response to load changes in common hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
1500
1000 1000
1500 1500 100
100 50
50
500
500 1000
1000
0 0 50
0 0 50
5000 0500 2 4 6 8 10
2 4 6 8 10
Flow (GPM) 0 Flow (GPM) 0
0 0
Port 2 to 3 Port 3 to 1 0 2 2 to 3
Port 4 Port 2 to 3 6 8 10
0 2 4 6 8 10
Flow (GPM) Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP88
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DF-PRP – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
PRESSURE RANGE
3000 100 - 3000 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP89
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
16 size, 1 5/16-12 thread, “Super” series, pilot operated pressure reducing, relieving valve.
OPERATION
The SK-PRP in its steady state, allows flow to pass from (2) to (3), with the spring chamber constantly drained
at (1). When a pre-determined pressure is reached at (3), the spool shifts to restrict input flow at (2), thereby
reducing (restricting) flow. If the valve and pressure at port (3) exceeds setting, spool shifts to open passage
at port (1), thereby regulating pressure at (3) by relieving excess flow. The cartridge offers smooth transition in
response to load changes in common hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
50
Pressure Drop (bar)
1500
Cavity 500 SUPER 3W
PERFORMANCE 100
Cavity Form Tool (Finishing) 40500018
1000
Actual Test Data (Cartridge Only) 50
Seal Kit 0 21191406 0
500 0 5 10 15 20
Flow (GPM)
0 0
Port 2 to 3 Port 2 to 3
0 5 10 15 20
Flow (GPM)
Flow (LPM)
Port 2 to 3 Port 2 to 3 Flow (LPM)
0 25 50 75 0 25 50 75
2500 Flow (LPM)
0 25 50 75 1500 100
1500 100
150
2000
Pressure Drop (PSI)
1000
1500
1000
100
50
50
1000
500
50 500
500
0 0
0 5 10 15 20
0 Flow (GPM) 0 0 0
0 5 10 15 20 0 5 10 15 20
Port 2 to 3 Port 3 to 1 (valve set @ 1000 PSI)
Flow (GPM)
Flow (GPM)
Port 2 to 3 Port 2 to 3
Port 2 to 3 Port 3 to 1 (valve set @ 1000 PSI)
Flow (LPM)
0 25 50 75
1500 100
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
1000
50
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
500
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP90
0 0
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
SK-PRP – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 S #12 SAE Ports
Buna, Knob 0K
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI PRESSURE RANGE/SETTING
Buna, Tamper Proof 0T Ext./Int. Adjustable
Viton, Tamper Proof VT 3000 500 - 3000 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP91
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pilot operated pressure reducing, relieving valve.
OPERATION
The DF-PWP in its steady state, allows flow to pass from (2) to (3), with the spring chamber constantly drained
at (1). When a pre-determined pressure is reached at (3), the spool shifts to restrict input flow at (2), thereby
reducing (restricting) flow. If valve and pressure at port (3) exceeds setting, spool shifts to open passage at port
(1), thereby regulating pressure at port (3) by relieving excess flow. The cartridge offers smooth transition in
response to load changes in common hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
150 150
Regulated Pressure (PSI)
1000 1000
1500 100 1500 100
50 50
500 500
1000 1000
50 0 0 50
0 0 500
500 0 2 4 6 8 10
0 2 4 6 8 10
Flow (GPM) Flow (GPM)
0 0
0 0
Port 2 to 3 Port 3 to 1 0 Port
2 2 to 3 4 Port 2 to 3 6 8 10
0 2 4 6 8 10
Flow (GPM) Flow (GPM)
Port 2 to 3 Port 3 to 1 Port 2 to 3 Port 2 to 3
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP92
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DF-PWP – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI PRESSURE RANGE/SETTING
Buna, Tamper Proof 0T Ext./Int. Adjustable
Viton, Tamper Proof VT 4000 100 - 4000 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP93
MECHANICAL PRESSURE CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP94
MECHANICAL PRESSURE CONTROLS
SEQUENCE VALVES
TYPICAL SCHEMATIC
Typical application for the PSO or PSC sequence valve is for a high/low application like a log splitter where the spring chamber can be vented
externally (spring chamber pressure directly adds to the pilot pressure required to shift the valve). Typical application for the PWI sequence valve
is for controlling the lip on a dock leveler. Typical application for the PWE sequence valve is for a high/low pump in a positive traction circuit where
the valve automatically shifts to low speed high torque mode. Typical application for the PSI sequence valve is when starting against load where the
spring chamber can be vented externally (spring chamber pressure directly adds to the pilot pressure required to shift the valve). Typical application
for the PSA sequence valve is a hydraulic brake release of a spring loaded single acting cylinder. Typical application for the PSS hot oil shuttle is
to divert fluid from the low pressure side of a closed loop hydrostatic transmission for cooling or filtering.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP95
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, 4 way external pilot sequence valve.
OPERATION
The DG-PSA in neutral (un-piloted), allows flow between (1) and (2) bidirectionally, while blocking at (3). The
spring chamber is constantly vented at (1). On attainment of a predetermined pressure at (4), the cartridge shifts
to close (1) to (2), while opening (2) to (3). Note that the backpressure value at (1) must be added to the selected
pressure setting to determine pilot pressure necessary to open valve.
FEATURES
• Optional spring ranges to 1500 PSI (103 bar).
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Orifice .030 to .060 diameter recommended
beneath port (4).
Flow (LPM)
0 10 20 30 40
200
Pressure Drop (BAR)
Pressure Drop (PSI)
150 10
PERFORMANCE VALVE SPECIFICATIONS
100
Actual Test Data (Cartridge Only) Nominal Flow 10 GPM (38 LPM)
5
Rated Operating Pressure 3000 PSI (207 bar)
50 Flow (LPM)
0 10 20 30 40
Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)
200
0 0 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 2 4 6 8 10 12 Filtration ISO 18/16/13
Pressure Drop (BAR)
Flow (GPM)
Pressure Drop (PSI)
Port 2 to 3 Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP96
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DG-PSA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T
Viton, Tamper Proof VT PRESSURE RANGE
0425 50 - 425 PSI
1500 425 - 1500 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP97
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, 2 way normally closed sequence valve, external pilot.
OPERATION
The DG-PSC in neutral (unpiloted), blocks flow between (3) and (2). The spring chamber is constantly vented at
(1). On attainment of a predetermined pressure at (4), the cartridge shifts to allow flow from (3) to (2). Note that
the backpressure value at (1) must be added to the selected pressure setting to determine pilot pressure.
FEATURES
• Optional spring ranges to 1500 PSI (103 bar).
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Orifice .030 to .060 diameter recommended
beneath port (4).
Flow (LPM)
0 10 20 30 40
200
Pressure Drop (PSI)
150
Pressure Drop (bar)
10
PERFORMANCE VALVE SPECIFICATIONS
Actual
100Test Data (Cartridge Only) Nominal Flow 10 GPM (38 LPM)
5 Rated Operating Pressure 3000 PSI (207 bar)
50 Flow (LPM)
Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)
0 10 20 30 40
200 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 0
0 2 4 6 8 10 12 Filtration ISO 18/16/13
Flow (GPM) Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (PSI)
150
Pressure Drop (bar)
10
Port 2 to 3 Weight .63 lbs (.28 kg)
100 Operating Fluid Media General Purpose Hydraulic Fluid
5 Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
50 Cavity DELTA 4W
Cavity Form Tool (Finishing) 40500002
0 0 Seal Kit 21191214
0 2 4 6 8 10 12
Flow (GPM)
Port 2 to 3
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP98
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DG-PSC – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T
Viton, Tamper Proof VT PRESSURE RANGE
0425 50 - 425 PSI
1500 425 - 1500 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP99
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, 3 way normally open internal pilot sequence valve.
OPERATION
The DG-PSI in neutral (un-piloted), allows flow between (3) and (2) bidirectional, while blocking at (4). The spring
chamber is constantly vented at (1). On attainment of a predetermined pressure at (4), the cartridge shifts to close
(3) to (2), while opening (4) to (3).
Note: that the backpressure value at (1) must be added to the selected pressure setting to determine pilot
pressure necessary to open valve.
FEATURES
• Optional spring ranges to 1500 PSI (103 bar).
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 5 10 15 20 25 30 35 40 45
2000
Pressure Drop (PSI)
1500 100
PERFORMANCE VALVE SPECIFICATIONS
1000
Actual Test Data (Cartridge Only) Nominal Flow 10 GPM (38 LTR/M)
50
Flow (LPM) Rated Operating Pressure 3000 PSI (207 bar)
500
0 5 10 15 20 25 30 35 40 45 Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)
2000 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 0
0 2 4 6 8 10 12 Filtration ISO 18/16/13
Pressure Drop (PSI)
1500 Flow (GPM) 100 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Port 4 to 3 Port 2 to 3 Weight .63 lbs (.28 kg)
1000 Operating Fluid Media General Purpose Hydraulic Fluid
50 Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
500 Cavity DELTA 4W
Cavity Form Tool (Finishing) 40500002
0 0 Seal Kit 21191214
0 2 4 6 8 10 12
Flow (GPM)
Port 4 to 3 Port 2 to 3
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP100
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DG-PSI – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T
Viton, Tamper Proof VT PRESSURE RANGE
0425 50 - 425 PSI
1500 425 - 1500 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP101
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, 2 way normally open sequence valve, external pilot.
OPERATION
The DG-PSO in neutral (un-piloted), allows flow between (3) and (2) bi-directionally. The spring chamber is
constantly vented at (1). On attainment of a predetermined pressure at (4), the cartridge shifts to block flow from
(3) to (2).
Note: that the backpressure value at (1) must be added to the selected pressure setting to determine pilot
pressure necessary to close valve.
FEATURES
• Optional spring ranges to 1500 PSI (103 bar).
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Orifice .030 to .060 diameter recommended
beneath port (4).
Flow (LPM)
0 10 20 30 40
150 10
125
Pressure Drop (PSI)
PERFORMANCE
100 VALVE SPECIFICATIONS
Flow (GPM)
100 Weight .62 lbs (.28 kg)
Port 2 to 3
Operating Fluid Media General Purpose Hydraulic Fluid
75 5
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
50 Cavity DELTA 4W
25 Cavity Form Tool (Finishing) 40500002
Seal Kit 21191214
0 0
0 2 4 6 8 10 12
Flow (GPM)
Port 2 to 3
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP102
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DG-PSO – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T
Viton, Tamper Proof VT PRESSURE RANGE
0425 50 - 425 PSI
1500 425 - 1500 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP103
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, hot oil shuttle valve.
OPERATION
The DG-PSS, with internal piloting at port (1) or (3), oil will flow from the port opposite of the port piloted to port
(2), thus removing oil from the low-pressure side for cooling or filtration purposes. The Valve is spring bias neutral,
relying solely on the internal pilot pressure signal to shift to either side. The DG-PSS is closed in transition.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 10 20 30 40
200
Pressure Drop (PSI)
PERFORMANCE
150 VALVE SPECIFICATIONS
Pressure Drop (bar)
10
Actual Test Data (Cartridge Only) Nominal Flow 12 GPM (45 LTR/M)
100
Rated Operating Pressure 3000 PSI (207 bar)
5
Flow (LPM) Typical Internal Leakage (150 SSU) 5 cu/in per/min (82 ml/min)
50
0 10 20 30 40 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
200
0 0
Filtration ISO 18/16/13
0 2 4 6 8 10 12 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (PSI)
10
Port 3 to 2 Port 1 to 2 Operating Fluid Media General Purpose Hydraulic Fluid
100 Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
5 Cavity DELTA 4W
50 Cavity Form Tool (Finishing) 40500002
Seal Kit 21191212
0 0
0 2 4 6 8 10 12
Flow (GPM)
Port 3 to 2 Port 1 to 2
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP104
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DG-PSS – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
CRACK PRESSURE
0040 40 PSI
0080 80 PSI
0120 120 PSI
0160 160 PSI
0000 0 PSI (NO SPRING)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP105
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, external pilot, normally open.
OPERATION
The DG-PTC allows flow at ports (3) and (2). On attainment of a predetermined pressure at port (4), the valve
shifts to block flow from port (3) to (2). Spring Chamber is constantly vented to port (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Orifice .030 to .060 diameter recommended
beneath port (4).
Flow (LPM)
0 10 20 30 40 50
350
300 20
PERFORMANCE VALVE SPECIFICATIONS
Pressure Drop (PSI)
250
Actual Test Data (Cartridge Only) 15 Nominal Flow 10 GPM (38 LTR/M)
200
Rated Operating Pressure 3000 PSI (207 bar)
150 Flow (LPM) 10 Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)
0 10 20 30 40 50 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
100
350 5 Filtration ISO 18/16/13
50
300 20 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
0 0
Weight .39 lbs (.17 kg)
Pressure Drop (PSI)
250 0 2 4 6 8 10 12 14
15 Operating Fluid Media General Purpose Hydraulic Fluid
200 Flow (GPM)
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
150 10 Cavity DELTA 4W
100 Cavity Form Tool (Finishing) 40500002
5 Seal Kit 21191108
50
0 0
0 2 4 6 8 10 12 14
Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP106
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DG-PTC – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
SPRING BIAS
0050 50 PSI
0180 180 PSI
±10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP107
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, external pilot, normally closed.
OPERATION
The DG-PTO blocks flow at ports (3) and (2). On attainment of a predetermined pressure at port (4), the valve
shifts to allow flow from port (3) to (2). Spring Chamber is constantly vented to port (1).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Orifice .030 to .060 diameter recommended
beneath port (4).
Flow (LPM)
0 10 20 30 40 50
350
PERFORMANCE VALVE SPECIFICATIONS
300 20
Actual Test Data (Cartridge Only) Nominal Flow 10 GPM (38 LTR/M)
Pressure Drop (PSI)
250
Rated Operating Pressure 3000 PSI (207 bar)
15
200 Flow (LPM) Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)
150
0 10 20 30 40 50 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
10
350
100
Filtration ISO 18/16/13
300 5 20 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
50
Weight .39 lbs (.17 kg)
Pressure Drop (PSI)
250
0 0 15 Operating Fluid Media General Purpose Hydraulic Fluid
200 0 2 4 6 8 10 12 14
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
Flow (GPM)
150 10 Cavity DELTA 4W
100 Cavity Form Tool (Finishing) 40500002
5 Seal Kit 21191108
50
0 0
0 2 4 6 8 10 12 14
Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP108
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DG-PTO – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
SPRING BIAS
0050 50 PSI
0180 180 PSI
±10%
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP109
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, external pilot normally closed, sequence valve.
OPERATION
The DF-PWE blocks flow at ports (2) and (1). On attainment of a predetermined pressure at (3) the valve shifts
to a allow flow from (1) to (2).
FEATURES
• Hardened parts for long life.
• Optional spring ranges to 1500 PSI (103 bar).
• Industry common Cavity.
HYDRAULIC SYMBOL
Orifice .030 to .060 diameter recommended
beneath port (3).
Flow (LPM)
0
PERFORMANCE 5 10 15 20 25 30 35 40 45 50 VALVE SPECIFICATIONS
200
Actual Test Data (Cartridge Only) Nominal Flow 10 GPM (38 LTR/M)
Rated Operating Pressure 3000 PSI (207 bar)
Pressure Drop (PSI)
150 10
50 Weight .57 lbs (.26 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
100
0 Cartridge
0 Torque Requirements 30 ft-lbs (40.6 Nm)
5
0 2 4 6 8 10 12 Cavity
14 DELTA 3W
50
Cavity Form Tool (Finishing) 40500001
Flow (GPM)
0 0 Seal Kit 21191206
Port 1 to 2
0 2 4 6 8 10 12 14
Flow (GPM)
Port 1 to 2
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP110
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DF-PWE – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T
Viton, Tamper Proof VT SPRING BIAS
0425 50-425 PSI
1500 425-1500 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP111
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, internal pilot and drain, sequence valve.
OPERATION
The DF-PWI blocks flow at (3) and allows flow from (2) to (1). On attainment of a predetermined pressure at (3)
the valve shifts to a allow flow from (3) to (2) and block flow at (1).
FEATURES
• Hardened parts for long life.
• Optional spring ranges to 1500 PSI (103 bar).
• Industry common Cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 10 20 30 40
2000
1500
Pressure Drop (bar)
100
Actual Test Data (Cartridge Only) Nominal Flow 8 GPM (30 LPM)
1000 Rated Operating Pressure 3000 PSI (207 bar)
Flow (LPM)
50 Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)
0 10 20 30 40
500 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
2000
Filtration ISO 18/16/13
0 0 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Pressure Drop (PSI)
1500
Pressure Drop (bar)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP112
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DF-PWI – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T
Viton, Tamper Proof VT PRESSURE RANGE
0425 50-425 PSI
1500 425-1500 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 - 500 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP113
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
16 size, 1 5/16-12 thread, “Super” series, internal pilot normally closed, sequence valve.
OPERATION
The SL-PWA blocks flow from ports (3) to (2). On attainment of a predetermined pressure at (3) the valve shifts
to allow flow from (3) to (2). Port (1) should be a tank line.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 15 30 45 60 75 90
2000 135
PERFORMANCE 120 VALVE SPECIFICATIONS
Pressure Drop (bar)
Pressure Drop (PSI)
1500
Actual Test Data (Cartridge Only) 105 Nominal Flow 40 GPM (151 LPM)
90 Rated Operating Pressure 3500 PSI (241 bar)
Flow (LPM) 75 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
1000
60 Filtration ISO 18/16/13
0 15 30 45 60 75 90
45 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
2000 500 13530
Weight 1.15 lbs (.52 kg)
12015
Operating Fluid Media General Purpose Hydraulic Fluid
Pressure Drop (bar)
Pressure Drop (PSI)
1500 0 1050
Cartridge Torque Requirements 90 ft-lbs (122 Nm)
0 5 10 15 20 90
25
Cavity SUPER 3WS
Flow (GPM)
75
1000 Cavity Form Tool (Finishing) 40500021
60
Seal Kit 21191404
45
500 30
15
0 0
0 5 10 15 20 25
Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP114
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
SL-PWA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 S #12 SAE Ports
Buna, Knob 0K
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T
Viton, Tamper Proof VT PRESSURE RANGE/SETTING
3000 500-3000 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 2000 = 2000 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP115
MECHANICAL PRESSURE CONTROLS
SL-PWB SEQUENCE VALVE, NORMALLY CLOSED, INTERNAL PILOT WITH REVERSE FREE FLOW
DESCRIPTION
16 size, 1 5/16-12 thread, “Super” series, internal pilot normally closed, sequence valve w/ reverse free flow.
OPERATION
The SL-PWB blocks flow from ports (3) to (2). On attainment of a predetermined pressure at (3) the valve shifts
to allow flow from (3) to (2). Port (1) should be a tank line. Reverse flow from (2) to (3) occurs when the pressure
at port (2) is at least 45 PSI (3.1 bar) higher than at port (3).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Flow (LPM)
0 15 30 45 60 75 90
2000 135
PERFORMANCE 120 VALVE SPECIFICATIONS
Pressure Drop (bar)
Pressure Drop (PSI)
1500
Actual Test Data (Cartridge Only) 105 Nominal Flow 40 GPM (151 LPM)
90 Rated Operating Pressure 3500 PSI (241 bar)
Flow (LPM) 75
1000 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
0 25 50 75 100 125 150 60 Filtration ISO 18/16/13
2500 45 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
500 150 30
Weight 1.15 lbs (.52 kg)
2000 15
Operating Fluid Media General Purpose Hydraulic Fluid
0 0
Pressure (PSI)
Pressure (bar)
1500
Cartridge Torque Requirements 90 ft-lbs (122 Nm)
0 5 10 15 20 10025
Cavity SUPER 3WS
Flow (GPM) Cavity Form Tool (Finishing) 40500021
1000
50
Seal Kit 21191404
500
0 0
0 10 20 30 40
Flow (GPM)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP116
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
SL-PWB – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 S #12 SAE Ports
Buna, Knob 0K
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T
Viton, Tamper Proof VT PRESSURE RANGE/SETTING
3000 500-3000 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 2000 = 2000 PSI
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP117
MECHANICAL PRESSURE CONTROLS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP118
MECHANICAL PRESSURE CONTROLS
TYPICAL SCHEMATIC
Typical application for the PSD is a system protector, like a relief valve, but once this valve opens it will not reseat until the pressure at port (2) is
drained off. This valve is not to be used as a load holding device.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP119
MECHANICAL PRESSURE CONTROLS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pressure shut down valve.
OPERATION
The DE-PSD blocks flow from (2) to (1) until sufficient pressure is present at (2) to open the pilot, thereby forcing
the spool to open and allowing flow from (2) to (1). The valve stays open until the differential pressure from (2) to
(1) decreases to less than 50 PSI (3.4 bar).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
HYDRAULIC SYMBOL
Usually the valve requires flow to be reduced to
near zero before the valve will reset.
Flow (LPM)
0 25 50 75
200
150 10
Actual Test Data (Cartridge Only) Nominal Flow 15 GPM (57 LPM)
100 Rated Operating Pressure 4500 PSI (310 bar)
Flow (LPM) 5 Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
50
0 25 50 75 Filtration ISO 18/16/13
200
0 0 Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
0 5 10 15 20 Weight .53 lbs (.24 kg)
Pressure Drop (PSI)
150 10
Flow (GPM) Operating Fluid Media General Purpose Hydraulic Fluid
Port 2 to 1 Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
100
5 Cavity DELTA 2W
50 Cavity Form Tool (Finishing) 40500000
Seal Kit 21191200
0 0
0 5 10 15 20
Flow (GPM)
Port 2 to 1
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 19 / 2020
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP120
MECHANICAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
DE-PSD – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
Buna, Knob 0K S #8 SAE Ports
Viton, Knob VK
Buna, Internal Adjust 0I
Viton, Internal Adjust VI
Buna, Tamper Proof 0T
Viton, Tamper Proof VT PRESSURE RANGE/SETTING
3000 100-3000 PSI
4500 3000-4500 PSI
Tamper Proof
Fill in 4 Digit Pressure Setting
Example: 0500 = 500 PSI
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: [email protected] • www.delta-power.com mail: [email protected] • www.tecnord.com
Page MP121