Change Log EMU
Change Log EMU
218
• Custom fuel correction table
• New modes for Sync without camsync: Sync as soon as CAM is decoded or Sync at first fuel cut
• Export log to CVS fixed
• CAM based trigger with the missing tooth support added. The number of tooth must be equal to the half of
tooth on the trigger wheel (eg. for 24-1 it must be 12)
• EDL logs now display proper time when selected option Display System Time.
• CAN Analog inputs issue (wrong voltage scale) introduced in version 1.212 fixed
• CAN Analog inputs can be used with the Launch control Analog RPM control input
• Gear detection based on gear position sensor bug fixed (spikes when there was no VSS signal connected)
• Desktops are saved correctly during firmware upgrade
• Scatter plots
• Stepper motor support improved
• Idle control: when stepper motor is used, it is possible now to keep it powered when the MAP is
above defined target. It prevents stepper motor to move during boost.
• VTEC: Additional parameter to activate vtec over given RPM, independent to other parameters
• Honda S2000 (F20C) CAM#2 support added for faster synchronization
• Interrupts management modified
EMU Client
• USB communication improved
EMU Client
• CAN EGT channels are displayed correctly on the log
EMU Client
• Pop up menu for log window allows easy channels configuration
• Auto scale of Y axis for log channel could be set
• Import of DL1 logs time base bug fixed
EMU Client
• CPU revision displayed in about box
EMU Client
• Auto scaling of 3D Graph modified
• SHIFT+O and SHIFT+P shortcuts changed to CTRL+SHIFT+P and CTRL+SHIFT+O
• 2JZ VVTI electronic throttle added to the wizard
EMU Client
• Outputs tester
• Channel logs presets could be defined by user
• If calibration defined in windows client software differs from the configuration in EMU device. the user could
select what calibration should be used
EMU Client
• Collapse option tree view shortcut added ( CTRL + \)
EMU Client
• Used outputs list improved (fixed support of ignition outputs)
EMU Client
• Real time logging improved
• Show assigned inputs option added
EMU Client
• When upgrading to the same firmware version the calibration and desktops are loaded correctly
• Analog inputs definition (Sensor / Analog inputs) fixed
EMU Client
• Import of Lambda / AFR target from serial datalog fixed
EMU Client
• Clear log crash fixed in the case of using disable logging when paused
EMU Client
• Crash during log clear when alarms enabled fixed
EMU Client
• Honda CLT/IAT sensors wizard fixed (thanks Przema)
EMU Client
• Alarms added (on gauges and on toolbar)
EMU Client
• Fueling help restored
• Fuel / General paramblock description fixed
• Suzuki Swift 1.6 throttle added to DBW Wizard
EMU Client
• Crash during clearing log fixed
EMU Client
• Autosaving logs (general options / Log / Auto save log)
• Log recording can be suspended when Log is paused ( General options / Log / Stop logging when paused)
• Connecting new device bug fixed (crash)
• Conditional logging
• Autotune for AlphaN bug fixed
EMU Client
• Log timing can be PC current time based (general options / Log / Display system time)
• Log channels can be configured (min, max, redline). Alarms are not working yet
EMU Client
• Firmware upgrade bug fixed
• During firmware upgrade, in the device directory there is automatically backup of current calibration
EMU Client
• P65 coils wizard definitions fixed
• Autotune bug with TPS parameters fixed
• EMU protocol import fixed
EMU Client
• Autotune bugs fixed and improvements
• AFR/Lambda target table bug with Load on Y axis fixed
EMU Client
• Import of Ecumaster serial protocol log from Keelog Ghost serial dataloger and Dashboard tablet
EMU Client
• Unused strategies can be hidden in client software (Tools / Available strategies)
EMU Client
• Extra desktop 4 and 5 added
• Gauge word removed from gauge window title bar
EMU Client
• AC clutch can be disable if CLT is greater than defined
Change log for version 1.122 EXP1
• VSS can be calculated based on CAN wheel speed
• Flat shift new parameters: ignition retard and fuel enrichment
EMU Client
• AC clutch state displayed on the client status bar
EMU Client
EMU Client
• Windows redraw modified
EMU Client
• CPU usage reduced
• USB communication improved
EMU Client
• CPU usage reduced
• USB communication improved
Due to the bug with charge temperature calculations, firmware version 1.110, 1.111, 1.112, 1.113 must be
upgraded to 1.115!!!
EMU Client
• Minor corrections
EMU Client
• Application doesn't require administrator rights,
• File association moved from application to installer,
• Table entries division operator bug fixed
• SSE2 instruction support disabled to maintain compatibility with older CPUs
• Auto positioning of new tables on free desktop area
• Windows snapping
• New customization window
• New gauges layouts added
• OpenGL optimization
• Auto hide option panel added
• Gauges flickering fixed
• New status bar with CEL details
• New upgrade firmware interface (two progress bars)
• Application termination (exit) bug fixed. Now it always exit.
EMU Client
• EMU files (.emu, .emulog, .emuscp) are associated with the application. EMU client will open the files if
double clicked
• Divide operator added to cell modify operators (eg. 2/ divides cells by 2)
EMU Client
• Maximization of windows fixed
• Real time autotune
• Tune display
• Flickering of windows fixed (?)
EMU Client
• Windows XP incompatibility bug fixed
• New electronic throttles added to the wizard
EMU Client
• Application build using the latest Microsoft compiler and latest wxWidgets library
• UI no longer flickers
• The size of paramlist windows and group log windows should be optimal
• Keys assignment may change due to new wxWidgets library (assigning new keys might be required)
EMU Client
• Bin axis wizard works with non integer numbers
EMU Client
• OpenGL crash fixed
• Desktops could be renamed
• Some speed optimization
• New injectors added to Injectors Wizard
• UI flickering problem improved
Change log for version 1.1 BETA
• WBO Heater support improved
EMU Client
• Clear log crash fixed
• OpenGL support improved
• Next/Previous tab shortcuts added ],[ keys
• Save / Load desktop layouts
• Help for all EMU options added
• Contributors list added
EMU Client
• IDL flag added to status bar
• Close all windows option bug fixed (crash)
• Bug with closing windows fixed (crash)
• TAB key switches between options tree view and child windows
EMU Client
• New flags added to status bar
• About box shows device serial number
• Throttle Bosch 0280750030 added to the DBW Wizard
EMU Client
• Customize keys, new shortcuts added
• New option for 3D tables added (automodify cells above cursor)
IMPORTANT: The engine noise table prepared with the previous software version should be lowered about
0.22V due to change in dynamic range of knock sensor input.
EMU Client
• Customize keys (Tools / Customize keys)
• Bug with Select All fixed
EMU Client
• 20Hz dataloging (previous 10Hz)
• Log window improved:
• scaling
• HOME/END keys
• 0.1 sec bars when scaled up
• Tables configuration bug fixed (color scheme selection)
EMU Client
• Desktops are saved to disc before firmware upgrade
EMU Client
• Bugs and crashes from 1.054 corrected
• Bug trap added for easy crash report submission
EMU Client
• DBW Wizard
• CSV text file has column time
• 3D tables cross hair display method changed
EMU Client
• Export selected log channels to CSV text file (separation character is ; )
Change log for version 1.047 EXP1
• Delta fuel pressure correction
• Delta fuel pressure fail safe with RPM limit
• WBO error detection improved
• 3UZ-fe cam decoder
EMU Client
• Engine status is displayed correctly (Running instead afterstart)
• Windows with parameters have correct height (all parameters are visible without scroll bar)
EMU Client
• UI outlook improved for large system fonts
• Windows with 3D tables splitting strategy improved
• Help for parameters windows introduced (actually only for TPS and Oil pressure cut)
• Log can be scrolled with mouse wheel
• Bug with scrolling log using keys fixed
• User manual is installing with the software
• Error codes are displayed by name not a code number
EMU Client
• Bug from version 1.041 with gauges fixed
• Honda temperature sensor added to temp. sensors wizard
EMU Client
• Open 3D tables when load is on Y axis bug fixed
• Open / Save file dialogs opens in last visited directory. When device connected directory is changed to device
name dir.
EMU Client
• 3D tables position and size are handled correctly
• Traction control
EMU Client
• When loading project 3D tables with load on axis are updated correctly (AlphaN vs Speed density)
EMU Client
• Load on Y axis bug fixed
EMU Client
• Load on Y axis bug fixed (storing tables to EMU)
• Magneti Marelli temperature sensors added (AST04 and WST04)
• Magneti Marelli BAE 801 double coils wizard added
EMU Client
• Configuration for 3D tables (load axis definition, color scheme)
• Password protected EMU can be reset to factory settings
EMU Client
EMU Client
• New operators for table editing added. Numbers with operator * multiply cells value (eg. 0,5* ), operator + and
– adds and subtracts values (eg. 7+ adds 7 to all selected cells).
EMU Client
• CEL (Check engine light) on status bar
EMU Client
• Ethanol content gauge
EMU Client
EMU Client
• 3D tables selection outlook improved
• Temperature snsor wizard improved. Error message for wrong sensor data
• Road dyno
EMU Client
•
EMU Client
• Log groups are sorted in main tree view
• Gauges are sorted in main tree view
• CLT gauge scale overlap fixed
EMU Client
• Paste bug fixed when paste to selected area
EMU Client
• Improved lost log frame support.
• Reduced flickering of text log controls
• Copy / Paste for cells of 2D and 3D tables (CTRL+C, CTRL+V)
EMU Client
• Sound added for make permanent function.
• Text items in log windows are sorted and colored
EMU Client
• CLT wizard transfers the whole table to EMU
EMU Client
• Assigned outputs list
EMU Client
• Tables colors recalculate correct if there is no 3D graph
EMU Client
+ log window scrollbar functionality improved
+ when disconnected you can always scroll log
+ log could be scrolled with keys. Arrows scroll by 2, shift + arrows scroll by 10, page up/ page down scroll by 32
+ space key on log window pause / resume logging
+ cancel button on log preset window works correct
+ autoscale for 3d graphs
+ changing bins correctly re-interpolates all dependent tables
+ x axis bins wizard bug fixed
EMU Client
+ log file name bug fixed
EMU Firmware
+ CLT range increased to 250C
+ invert output for main relay
+ changing output for main relay disable previous output
EMU Client
+ making permanent feedback on connection status
+ making permanent saves current project into QuickSave directory of current device
+ VW Beetle CLT sensor added
+ Log file name format improved
+ Boost target could be lower than 100kPa
EMU Firmware
+ Porsche trigger (4 cylinder 132 teeth + 1 on cranksahft)
Change log for version 0.999 EXP7
EMU Client
+ colours added to connection status
+ automatic reconnection
+ software doesn't hang when loosing USB connection with EMU device.
EMU Client
EMU Client