0% found this document useful (0 votes)
148 views

Thordarson 23V367 Isolation Transformer

The document describes Thordadson power transformers that can step up or step down voltages from 115 to 115 volts, or from 230 to 115 volts, with frequencies of 50-60 Hertz. It provides specifications for various transformer models including their input/output voltages and currents, dimensions, mounting details, and weights. The transformers offer isolation and have electrostatic shields connected to ground for safety.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
148 views

Thordarson 23V367 Isolation Transformer

The document describes Thordadson power transformers that can step up or step down voltages from 115 to 115 volts, or from 230 to 115 volts, with frequencies of 50-60 Hertz. It provides specifications for various transformer models including their input/output voltages and currents, dimensions, mounting details, and weights. The transformers offer isolation and have electrostatic shields connected to ground for safety.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

THORDADSON POWER TRANSFORMERS

STEP UP + STEP DOWN + 115 TO 115 VOLTS


ISOLATION TRANSFORMERS
115 Volts TO 115 Volts, 50 - 60 Hertz - Isolation & Electrostatic Shield
3 Conductor Input Line Cord & Output Cord with Plug
Case & Electrostatic Shield are Connected to Ground
Dimensions-Inches
RMS Case Mounting
Part Input Output VA Test Wt.
Number Volts Volts Cap. Volts Style H W D MW MD Lbs.
23V364 115 115 100 1500 GMV 3 1/2 2 13/16 3 9/16 2 1/4 2 7/16 5.5
23V365 115 115 150 1500 GMV 3 7/8 3 1/8 4 3/16 2 1/2 2 15/16 7.0
23V366 115 115 250 1500 GMV 4 5/8 3 3/4 4 3/8 3 3 3/16 10.0
23V367 115 115 500 1500 GMV 4 11/16 3 3/4 6 3 4 13/16 16.5
23V368 115 115 1000 1500 GMV 5 1/2 4 9/16 8 1/8 3 1/2 6 1/2 31.5

230 Volts to 115 Volts, 50 - 60 Hertz - Isolation & Electrostatic Shield


3 Conductor Input Line Cord & Output Cord with Plug
Case & Electrostatic Shield are Connected to Ground
23V369 230 115 100 1500 GMV 3 1/2 2 13/16 3 9/16 2 1/4 2 7/16 4.5
23V372 230 115 500 1500 GMV 4 11/16 3 3/4 6 3 4 13/16 16.0
23V373 230 115 1000 1500 GMV 5 1/2 4 9/16 8 1/8 3 1/2 6 1/2 31.0
Primaries have Lead Wire Terminations, except 23V395 has a 3 Conductor Line Cord
Secondaries have a Female Plug, Case Mounted, except 23V395 has Lead Wires
Electrostatic Shield with Seperate Lead Wire, except 23V17 is Connected to Ground
23V376 #@ 115 115 $ .6 1500 BAH 1 1/4 2 1/8 1 1/4 1 3/4 — .3
23V374 #@ 115 115 $ 15 1500 BAH 2 3 1/4 1 7/8 2 13/16 — 1.0
23V17 # 115 115 $ 35 1500 BAH 2 1/4 3 11/16 2 1/8 3 1/8 — 1.8
23V74 #@ 115/230 & 115 $ 150 1500 GGV 3 7/8 3 1/4 4 1/4 2 1/2 3 7.0
23V395 @ 115 115/230 #&■ 150 1500 GMV 3 7/8 3 1/8 4 1/8 2 1/2 2 3/4 6.2

115 or 230 Volts to 115 Volts, 50-60 Hertz,


Except 23V548 Primary is 210 - 230 - 250 Volts & has Solder Lug Terminals
Case & Electrostatic Shield are Connected to Ground
Electrostatic Shield with Seperate Lead Wire, except 23V17 is Connected to Ground
23V80 #@ 115/230 & 115 35 1500 BAH 2 1/4 3 11/16 2 1/4 3 1/8 — 1.8
23V551 #@ 115/230 & 115 50 1500 BAH 2 1/4 3 11/16 2 3/8 3 1/8 — 1.7
23V548 T 210/230/250 115 $ 1500 1500 JMV 7 1/4 5 5/8 9 1/4 4 51/8 6 3/8 50.0
NOTE -- All Primaries 50/60 Hz
# These Parts have Lead Wire Terminations
@ Electrostatic Shield Has a Separat Lead Wire & is Not Grounded
& These Parts have 2 Separate 115 Volt Windings
T 23V548 Primary has Solder Lug Terminations
$ Secondaries have a Female Plug, except 23V548 has 2 Female Plugs

You might also like