CONVENTIONAL
GAS BOILERS
ALTEAS X GENUS X
24 30 32 35 24 30 32 35
Combi Combi
POWER RANGE FF 24-30-32-35 kW FF 24-30-32-35 kW
CF 24-30 kW CF 24-30 kW
EFFICIENCY Up to 93,6% & Reduced electrical consumption Up to 93,6% & Reduced electrical consumption
DISPLAY Large LCD & Touch screen display Large LCD & Touch screen display
SILENCE Modulating pump and insulating panels Modulating pump and insulating panels
COMFORT FUNCTION
PAGE 66 68
66 /
CLAS X CARES X
24 28 32 15 18 24
Up to 13%* Up to 13%*
Combi Combi
FF 24-28 kW FF 15-18-24 kW
CF 24 kW CF 15-24 kW
System System
FF 24-28-32 kW FF 24 kW
CF 15-24 kW CF 24 kW
Up to 93,6% Up to 93,6%
- -
70 74
/ 67
ALTEAS X
Wall-hung compact boiler with AUTO function
/ Very high efficiency (up to 93,6%, 24FF)
/ Ready to be used with renewable sources for hot water production
150
65 67 67 65 319 (24-30-32-35FF)
315 (24-30CF)
LEGEND
68 /
24 / 30 CF / 24 / 30 / 32 / 35 FF
TECHNICAL DATA 24 CF 30 CF 24 FF 30 FF 32 FF 35 FF
Graph of boiler’s residual head
Models 32/35 POWER SPECIFICATIONS
mCE Models 24/30 Max/min nominal heat input(Hi) kW 25,8/11,0 29,5/13,0 25,8/11,0 30,0/13,0 32,5/15,0 34,5/15,0
6
Max/min nominal heat input (Hs) kW 28,7/12,2 32,8/14,4 28,7/12,2 33,3/14,4 36,1/16,7 38,3/16,7
5
Max/min nominal heat input for hot water (Hi) kW 27,0/11,0 30,5/13,0 25,8/11,0 30,0/13,0 34,5/15,0 34,5/15,0
4
Max/min nominal heat input for hot water (Hs) kW 30,0/12,2 33,9/14,4 28,7/12,2 33,3/14,4 38,3/16,7 38,3/16,7
3 Heat output: max/min kW 23,7/9,9 26,5/11,2 24,0/9,5 28,1/11,6 29,6/12,8 32,3/13,2
2 D.H.W. Heat output: max/min kW 25,0/10,2 27,9/11,9 23,6/10,0 27,4/11,9 32,2/14,0 32,2/14,0
Combustion efficiency (of flue gas) % 92,7 92,8 93,7 93,8 93,1 93,9
1
Gross efficiency of nominal heat input (60/80 °C) Hi/Hs % 91,9/82,8 89,9/81,0 93,1/83,8 93,6/84,3 91,1/82,0 93,6/84,3
0 100 200 300 400 500 600 700 800 900 1000 1100
Gross efficiency at 30 % at 47°C Hi/Hs % 91,2/82,1 89,7/80,8 93,3/84,0 93,7/84,4 89,8/80,9 92,6/83,4
flow rate l/h Gross efficiency at minimum power Hi/Hs % 90,2/81,2 86,5/77,9 86,7/78,1 93,7/84,4 85,0/76,5 88,2/79,4
Number of efficiency stars (Directive 92/42/EEC) stars ★★ ★★ ★★★ ★★★ ★★★ ★★★
Ma. heat loss to the casing (ΔT = 50°C) % 0,8 2,9 0,6 0,2 2 0,3
CF Version - Natural draught Heat loss through the flue when burner on % 7,3 7,2 6,3 6,2 6,9 6,1
Heat loss through the flue when burner off % 0 ,4 0,4 0,4 0,4 0,4 0,4
EMISSIONS
Residual discharge head Pa - - 120 145 130 130
Minimun draw Pa 4,1 4,3 - - - -
FF Versions - Coaxial exhaust Nox class class 2 2 3 3 3 3
180 Flue fumes temperature (G20) °C 116 125 117 110 125 112
CO2 content2 (G20) % 5,4 6,1 6,5 6,1 6,4 6,4
180 CO content (0 %02) ppm 54 44 60 111 141 159
O2 content2 (G20) % 10,8 9,5 8,8 9,5 9 9
105
Max capacity fumes (G20) kg/h 67,2 70,2 56,9 71,2 77,2 77,2
Excess air % 105 83 72 83 75 75
105
Central heating temperature: max/min °C 82/35 82/35 82/35 82/35 82/35 82/35
Ø80/80: up to 45m (24kW) - 50m (28kW) - 33m (32-35 kW) Specific flow rate of domestic hot water system
l/min 11,8 13,2 11,2 13,2 15,1 15,1
(10 min. with ΔT=30°C) instant boilers
D.H.W. flow rate ΔT=25°C l/min 14,3 16 13,5 15,7 18,5 18,5
D.H.W. flow rate ΔT=35°C l/min 10,2 11,4 9,6 11,2 13,2 13,2
Hot water comfort stars (EN13203) stars ★★ ★★ ★★ ★★ ★★ ★★
D.H.W. minimum flow rate l/min <2 <2 1,7 1,7 1,7 1,7
Domestic hot water pressure max/min Mpa (bar) 0,7/0,1 (7/1) 0,7/0,1 (7/1) 0,7/0,1 (7/1) 0,7/0,1 (7/1) 0,7/0,1 (7/1) 0,7/0,1 (7/1)
ELECTRICAL
Power supply voltage/frequency V/Hz 220/50 220/50 220/50 220/50 220/50 220/50
Power consumption W 50 50 84 101 101 101
Minimum operating room temperature °C 5 5 5 5 5 5
Electric system grades of protection IP X5D X5D X5D X5D X5D X5D
Weight kg 27 28 31 32 30 31
CODE
/ 69
GENUS X
Wall-hung compact boiler with AUTO function
/ Very high efficiency (up to 93,8%, 24FF)
/ Ready to be used with renewable sources for hot water
production
150
65 67 67 65 319 (24-30-32-35FF)
315 (24-30CF)
LEGEND
70 /
24 / 30 / 32 / 35 CF / 24 / 30 FF
TECHNICAL DATA 24 CF 30 CF 24 FF 30 FF 32 FF 35 FF
Graph of boiler’s residual head
Models 32/35 POWER SPECIFICATIONS
mCE Models 24/30 Max/min nominal heat input(Hi) kW 25,8/11,0 29,5/13,0 25,8/11,0 30,0/13,0 32,5/15,0 34,5/15,0
6
Max/min nominal heat input (Hs) kW 28,7/12,2 32,8/14,4 28,7/12,2 33,3/14,4 36,1/16,7 38,3/16,7
5
Max/min nominal heat input for hot water (Hi) kW 27,0/11,0 30,5/13,0 25,8/11,0 30,0/13,0 34,5/15,0 34,5/15,0
4
Max/min nominal heat input for hot water (Hs) kW 30,0/12,2 33,9/14,4 28,7/12,2 33,3/14,4 38,3/16,7 38,3/16,7
3 Heat output: max/min kW 23,7/9,9 26,5/11,2 24,0/9,5 28,1/11,6 29,6/12,8 32,3/13,2
2 D.H.W. Heat output: max/min kW 25,0/10,2 27,9/11,9 23,6/10,0 27,4/11,9 32,2/14,0 32,2/14,0
Combustion efficiency (of flue gas) % 92,7 92,8 93,7 93,8 93,1 93,9
1
Gross efficiency of nominal heat input (60/80 °C) Hi/Hs % 91,9/82,8 89,9/81,0 93,1/83,8 93,6/84,3 91,1/82,0 93,6/84,3
0 100 200 300 400 500 600 700 800 900 1000 1100
Gross efficiency at 30 % at 47°C Hi/Hs % 91,2/82,1 89,7/80,8 93,3/84,0 93,7/84,4 89,8/80,9 92,6/83,4
flow rate l/h Gross efficiency at minimum power Hi/Hs % 90,2/81,2 86,5/77,9 86,7/78,1 93,7/84,4 85,0/76,5 88,2/79,4
Number of efficiency stars (Directive 92/42/EEC) stars ★★ ★★ ★★★ ★★★ ★★★ ★★★
Ma. heat loss to the casing (ΔT = 50°C) % 0,8 2,9 0,6 0,2 2 0,3
CF Version - Natural draught
Heat loss through the flue when burner on % 7,3 7,2 6,3 6,2 6,9 6,1
Heat loss through the flue when burner off % 0 ,4 0,4 0,4 0,4 0,4 0,4
EMISSIONS
Residual discharge head Pa - - 120 145 130 130
Minimun draw Pa 4,1 4,3 - - - -
FF Versions - Coaxial exhaust
Nox class class 2 2 3 3 3 3
180 Flue fumes temperature (G20) °C 116 125 117 110 125 112
CO2 content2 (G20) % 5,4 6,1 6,5 6,1 6,4 6,4
180 CO content (0 %02) ppm 54 44 60 111 141 159
105
Central heating temperature: max/min °C 82/35 82/35 82/35 82/35 82/35 82/35
334
243
ELECTRICAL
Power supply voltage/frequency V/Hz 220/50 220/50 220/50 220/50 220/50 220/50
Power consumption W 50 50 84 101 101 101
Minimum operating room temperature °C 5 5 5 5 5 5
Electric system grades of protection IP X5D X5D X5D X5D X5D X5D
Weight kg 27 28 31 32 30 31
CODE
/ 71
CLAS X NEW
200 200
180
25
125
130
745
150
28
65 67 67 65
315
A B C D E
KEY
72 /
24 CF EU / 28 CF EU / 24 CF NG / 24 / 28 FF
TECHNICAL DATA 24 CF EU 28 CF EU 24 CF NG 24 FF 28 FF
Boiler residual head
[mbar]
500 POWER SPECIFICATIONS
Max/min nominal calorific flow rate (Hi) kW 25,8/11 29,5/13 25,8/11 25,8/11 30/13
400
Max/min nominal calorific flow rate (Hs) kW 28,7/12,2 32,8/14,4 28,7/12,2 28,7/12,2 33,3/14,4
300 Domestic hot water max/min nominal calorific flow rate (Hi) kW 27/11 29,5/13 27/11 25,8/11 30/13
Domestic hot water max/min nominal calorific flow rate (Hs) kW 30/12,2 32,8/14,4 30/12,2 28,7/12,2 33,3/14,4
200
Max/min power output (80°C-60°C) kW 23,2/9,8 26,6/11,6 23,7/9,9 24/9,5 28,1/11,6
100 Domestic hot water max/min power output kW 24,3/9,9 26,6/11,7 25/10,2 23,6/10 27,4/11,9
Combustion efficiency (of flue gas) % 93,3 92,9 92,9 93,7 93,8
0
100 200 300 400 500 600 700 800 900 Nominal calorific flow rate efficiency (60/80°C) Hi/Hs % 90,1/81,1 90,2/81,2 91,9/82,8 93,1/83,8 93,6/84,3
[l\h] Efficiency at 30% at 47°C Hi/Hs % 89,9/81 90,3/81,3 91,2/81,2 93,3/84 93,7/84,4
Minimum calorific flow rate efficiency (60/80°C) Hi/Hs % 88,9/80,1 89,4/80,5 90,2/81,2 86,7/8,1 89,3/80,4
Efficiency rating (dir. 92/42/EEC) ★★ ★★ ★★ ★★★ ★★★
Sedbuk class classe D D D D D
Loss of burner gas when operating % 6,7 7,1 7,3 6,3 6,2
EMISSIONS
Available air pressure Pa - - - 120 145
NoX class class 6 6 2 3 3
Flue gas temperature (G20) (80°C-60°C) °C 111 119 116 117 110
CF versions - Natural draught
CO2 content (G20) (80°C-60°C) % -/- -/- 5,4 6,5 6,1
CO content (0%O2) (80°C-60°C) ppm 81/9 90/4 54 60 111
O2 content (G20) (80°C-60°C) % 10,4 10,1 10,8 6,5 9,5
Maximum flue gas flow (G20) (80°C-60°C) Kg/h 68,2 72,8 67,2 56,9 71,2
Excess air (80°C-60°C) % 98 93 105 72 83
HEATING CIRCUIT
Expansion chamber inflation pressure bar 1 1 1 1 1
Maximum heating pressure bar 3 3 3 3 3
Expansion chamber capacity l 6,5 6,5 6,5 6,5 6,5
Central heating temperature: max/min °C 82/35 82/35 82/35 82/35 35/82
Description N° of boilers per pallet
CLAS X 24 CF 14
CLAS X 28 CF 12 DOMESTIC HOT WATER CIRCUIT
Domestic hot water max/min temperature °C 60/36 60/36 60/36 60/35 60/35
Specific flow rate of domestic hot water (10 min - ΔT=30°C) l/min 12,2 13,2 11,8 11,2 13,2
Quantity of hot water ΔT=25°C l/min 14,6 15,8 14,3 13,5 15,7
Quantity of hot water ΔT=35°C l/min 10,5 11,3 10,2 9,6 11,2
Hot water comfort rating (EN13203) ★★★ ★★★ ★★ ★★ ★★
Hot water minimum flow rate l/min 2 2 2 2 2
Domestic hot water max pressure bar 7 7 7 7 7
ELECTRICAL
Power supply frequency/voltage V/Hz 230/50 230/50 230/50 220/50 220/50
Total electrical power absorbed W 52,1 52,1 78 108 131
Minimum ambient temperature for use °C 5 5 5 5 5
Protection level for the electrical appliance IP X4D X4D X4D X5D X5D
Weight kg 27 27 27 29 28
CODE
/ 73
CLAS X SYSTEM
Wall-hung compact boiler, ready to use
with external DHW tank
/ Very high efficiency (up to 93,6%, 28FF)
150
28
65 67 67 65 319 (24-28-32FF)
315 (24-28CF)
R
LEGEND
74 /
24 / 28 CF / 24 / 28 / 32 FF
TECHNICAL DATA 24 CF 28 CF 24 FF 28 FF 32 FF
Graph of boiler’s residual head
Model 32
Model 28 POWER SPECIFICATIONS
mCE Model 24
600 Max/min nominal heat input(Hi) kW 25,8/11,0 29,5/13,0 25,8/11,0 30,0/13,0 34,5/15,0
Max/min nominal heat input (Hs) kW 28,7/12,2 32,8/14,4 28,7/12,2 33,3/14,4 38,3/16,7
500
Max/min nominal heat input for hot water (Hi) kW 27,0/11,0 30,5/13,0 25,8/11,0 30,0/13,0 34,5/15,0
400
Max/min nominal heat input for hot water (Hs) kW 30,0/12,2 33,9/14,4 28,7/12,2 33,3/14,4 29,6/12,8
300 Heat output: max/min kW 23,7/9,9 26,5/11,2 24,0/9,5 28,1/11,6 32,3/13,2
200 D.H.W. Heat output: max/min kW 25,0/10,2 27,9/11,9 23,6/10,0 27,4/11,9 32,2/14,0
Combustion efficiency (of flue gas) % 92,7 92,8 93,7 93,8 93,1
100
Gross efficiency of nominal heat input (60/80 °C) Hi/Hs % 91,9/82,8 89,9/81,0 93,1/83,8 93,6/84,3 91,1/82,0
Gross efficiency at 30 % at 47°C Hi/Hs % 91,2/82,1 89,7/80,8 93,3/84,0 93,7/84,4 89,9/80,9
0 100 200 300 400 500 600 700 800 900 1000 1100
l/h Gross efficiency at minimum power Hi/Hs % 90,2/81,2 86,5/77,9 86,7/78,1 89,3/80,4 85,0/76,5
Number of efficiency stars (Directive 92/42/EEC) stars ★★ ★★ ★★★ ★★★ ★★★
Ma. heat loss to the casing (ΔT = 50°C) % 0,8 2,9 0,6 2
FF Versions - Coaxial exhaust Heat loss through the flue when burner on % 7,3 7,2 6,3 6,5 6,9
Heat loss through the flue when burner off % 0 ,4 0,4 0,4 0,4 0,4
180
180 EMISSIONS
Residual discharge head Pa - - 120 145 130
105
Ø60/100: up to 4m (24-28 kW) - 2m (32 kW) Flue fumes temperature (G20) °C 116 125 117 113 125
Ø80/125: up to 11m (24-28 kW) - 8 m (32 kW)
CO2 content2 (G20) % 5,4 6,1 6,5 6 6,4
FF Versions - Twin pipe exhaust 180 CO content (0 %02) ppm 54 44 60 111 141
O2 content2 (G20) % 10,8 9,5 8,8 9,7 9
180
Max capacity fumes (G20) kg/h 67,2 70,2 56,9 71,2 77,2
334 334
HEATING CIRCUIT
Expansion vessel pre-charged pressure Mpa (bar) 0,1 (1) 0,1 (1) 0,1 (1) 0,1 (1) 0,1 (1)
Ø80/80: up to 45m (24kW) - 50m (28kW) - 33m (32 kW) Maximum central heating circuit pressure Mpa (bar) 0,3 (3) 0,3 (3) 0,3 (3) 0,3 (3) 0,3 (3)
Expansion vessel capacity l 8 8 8 8 8
Central heating temperature: max/min °C 82/35 82/35 82/35 82/35 82/35
ELECTRICAL
Power supply voltage/frequency V/Hz 220/50 220/50 220/50 220/50 220/50
Power consumption W 78 78 108 131 127
Minimum operating room temperature °C 5 5 5 5 5
Electric system grades of protection IP X5D X5D X5D X5D X5D
Weight kg 27 28 29 28 31
CODE
/ 75
CARES X
Wall-hung compact boiler
/ Very high efficiency (up to 93,8%, 24FF)
180 (24FF)
400 191 (24CF)
770 (24CF)
745 (24FF)
150
65 67 67 65 319 (24FF)
315 (24CF)
B
LEGEND
76 /