You are on page 1/ 13

HEATING

CONVENTIONAL
GAS BOILERS

/ Comfort and ease of use for all requirements

/ Safety combined with the reliability of a brand specialised in


well-being
ARISTON CONVENTIONAL
WALL HUNG BOILER RANGE

ALTEAS X GENUS X

24 30 32 35 24 30 32 35

ENERGY SAVING Up to 15%* Up to 15%*

Combi Combi
POWER RANGE FF 24-30-32-35 kW FF 24-30-32-35 kW
CF 24-30 kW CF 24-30 kW

EFFICIENCY Up to 93,6% & Reduced electrical consumption Up to 93,6% & Reduced electrical consumption

CONNECTIVITY WI-FI embedded

DISPLAY Large LCD & Touch screen display Large LCD & Touch screen display

SILENCE Modulating pump and insulating panels Modulating pump and insulating panels

COMFORT FUNCTION

Glass frontal panel, black Black and white color


color, compact structure, design, compact structure,
DESIGN Italian design. Italian design.
Dimensions (H x L x W) Dimensions (H x L x W)
745 x 400 x 315 mm 745 x 400 x 315 mm

INTEGRATION WITH BusBridgeNetR technology ready, BusBridgeNetR technology ready,


OTHER PRODUCTS Solar System management Solar System management

PAGE 66 68

66 /
CLAS X CARES X

24 28 32 15 18 24

Up to 13%* Up to 13%*

Combi Combi
FF 24-28 kW FF 15-18-24 kW
CF 24 kW CF 15-24 kW

System System
FF 24-28-32 kW FF 24 kW
CF 15-24 kW CF 24 kW

Up to 93,6% Up to 93,6%

Large LCD Display Large LCD Display

- -

Compact structure, Compact structure,


Italian design. Italian design.
Dimensions (H x L x W) Dimensions (H x L x W)
745 x 400 x 315 mm 745 x 400 x 315 mm

BusBridgeNetR technology ready,


BusBridgeNetR technology ready
Solar System management

70 74

/ 67
ALTEAS X
Wall-hung compact boiler with AUTO function
/ Very high efficiency (up to 93,6%, 24FF)
/ Ready to be used with renewable sources for hot water production

/ Best enjoyable design of its category


/ High resolution LCD display with full text, touch interface and
intuitive menu

/ BusBridgeNet® communication protocol


/ Ariston Net embedded (Wi-Fi gateway on board)
/ Very good acoustic comfort thanks to the new optimized
silence

/ “AUTO function”, constant temperature for the maximum


thermic comfort
/ “Comfort Function”, instantaneous hot water, for 30’, after first
withdrawal, reducing waiting times
/ TIMER PROGRAMMING

/ Best materials available to guarantee high reliability and very


long lifecycle
/ Boiler protection from water impurities accumulation
/ Anti-freezing systems preventing freezing and scale accumulation
/ With its IPX5D, the protection, against water jet streams
(only FF version)

400 (24CF, 24-30FF) 180 (24-30-32-35FF)


440 (30CF-32-35FF) 191(24-30CF)
770 (24-30CF, 32-35FF)
745 (24-30FF)

150
65 67 67 65 319 (24-30-32-35FF)
315 (24-30CF)

LEGEND

A \ Central Heating Flow


B \ Domestic Hot Water Outlet
C \ Gas Inlet
D \ Domestic Cold Water Inlet
E \ Central Heating Return

68 /
24 / 30 CF / 24 / 30 / 32 / 35 FF

TECHNICAL DATA 24 CF 30 CF 24 FF 30 FF 32 FF 35 FF
Graph of boiler’s residual head
Models 32/35 POWER SPECIFICATIONS
mCE Models 24/30 Max/min nominal heat input(Hi) kW 25,8/11,0 29,5/13,0 25,8/11,0 30,0/13,0 32,5/15,0 34,5/15,0
6
Max/min nominal heat input (Hs) kW 28,7/12,2 32,8/14,4 28,7/12,2 33,3/14,4 36,1/16,7 38,3/16,7
5
Max/min nominal heat input for hot water (Hi) kW 27,0/11,0 30,5/13,0 25,8/11,0 30,0/13,0 34,5/15,0 34,5/15,0
4
Max/min nominal heat input for hot water (Hs) kW 30,0/12,2 33,9/14,4 28,7/12,2 33,3/14,4 38,3/16,7 38,3/16,7
3 Heat output: max/min kW 23,7/9,9 26,5/11,2 24,0/9,5 28,1/11,6 29,6/12,8 32,3/13,2
2 D.H.W. Heat output: max/min kW 25,0/10,2 27,9/11,9 23,6/10,0 27,4/11,9 32,2/14,0 32,2/14,0
Combustion efficiency (of flue gas) % 92,7 92,8 93,7 93,8 93,1 93,9
1
Gross efficiency of nominal heat input (60/80 °C) Hi/Hs % 91,9/82,8 89,9/81,0 93,1/83,8 93,6/84,3 91,1/82,0 93,6/84,3

0 100 200 300 400 500 600 700 800 900 1000 1100
Gross efficiency at 30 % at 47°C Hi/Hs % 91,2/82,1 89,7/80,8 93,3/84,0 93,7/84,4 89,8/80,9 92,6/83,4
flow rate l/h Gross efficiency at minimum power Hi/Hs % 90,2/81,2 86,5/77,9 86,7/78,1 93,7/84,4 85,0/76,5 88,2/79,4
Number of efficiency stars (Directive 92/42/EEC) stars ★★ ★★ ★★★ ★★★ ★★★ ★★★
Ma. heat loss to the casing (ΔT = 50°C) % 0,8 2,9 0,6 0,2 2 0,3
CF Version - Natural draught Heat loss through the flue when burner on % 7,3 7,2 6,3 6,2 6,9 6,1
Heat loss through the flue when burner off % 0 ,4 0,4 0,4 0,4 0,4 0,4

EMISSIONS
Residual discharge head Pa - - 120 145 130 130
Minimun draw Pa 4,1 4,3 - - - -
FF Versions - Coaxial exhaust Nox class class 2 2 3 3 3 3
180 Flue fumes temperature (G20) °C 116 125 117 110 125 112
CO2 content2 (G20) % 5,4 6,1 6,5 6,1 6,4 6,4
180 CO content (0 %02) ppm 54 44 60 111 141 159
O2 content2 (G20) % 10,8 9,5 8,8 9,5 9 9
105

Max capacity fumes (G20) kg/h 67,2 70,2 56,9 71,2 77,2 77,2
Excess air % 105 83 72 83 75 75
105

Ø60/100: up to 4m (24-28 kW) - 2m (32-35 kW)


Ø80/125: up to 11m (24-28 kW) - 8 m (32 kW) - 7 m (35 kW)
HEATING CIRCUIT
FF Versions - Twin pipe exhaust 180
Expansion vessel pre-charged pressure Mpa (bar) 0,1 (1) 0,1 (1) 0,1 (1) 0,1 (1) 0,1 (1) 0,1 (1)
Maximum central heating circuit pressure Mpa (bar) 0,3 (3) 0,3 (3) 0,3 (3) 0,3 (3) 0,3 (3) 0,3 (3)
180
Expansion vessel capacity l 8 8 8 8 8 8
334 334
243 243

Central heating temperature: max/min °C 82/35 82/35 82/35 82/35 82/35 82/35

DOMESTIC HOT WATER CIRCUIT


Domestic hot water temperature max/min °C 60/36 60/36 60/36 60/36 60/36 60/36

Ø80/80: up to 45m (24kW) - 50m (28kW) - 33m (32-35 kW) Specific flow rate of domestic hot water system
l/min 11,8 13,2 11,2 13,2 15,1 15,1
(10 min. with ΔT=30°C) instant boilers
D.H.W. flow rate ΔT=25°C l/min 14,3 16 13,5 15,7 18,5 18,5
D.H.W. flow rate ΔT=35°C l/min 10,2 11,4 9,6 11,2 13,2 13,2
Hot water comfort stars (EN13203) stars ★★ ★★ ★★ ★★ ★★ ★★
D.H.W. minimum flow rate l/min <2 <2 1,7 1,7 1,7 1,7
Domestic hot water pressure max/min Mpa (bar) 0,7/0,1 (7/1) 0,7/0,1 (7/1) 0,7/0,1 (7/1) 0,7/0,1 (7/1) 0,7/0,1 (7/1) 0,7/0,1 (7/1)

ELECTRICAL
Power supply voltage/frequency V/Hz 220/50 220/50 220/50 220/50 220/50 220/50
Power consumption W 50 50 84 101 101 101
Minimum operating room temperature °C 5 5 5 5 5 5
Electric system grades of protection IP X5D X5D X5D X5D X5D X5D
Weight kg 27 28 31 32 30 31

CODE

3300844 3300846 3300845 3300847 3300848 3300849

For complete list of accessories see page 82

/ 69
GENUS X
Wall-hung compact boiler with AUTO function
/ Very high efficiency (up to 93,8%, 24FF)
/ Ready to be used with renewable sources for hot water
production

/ Best enjoyable design of its category


/ High resolution LCD display with full text, touch interface
and intuitive menu

/ BusBridgeNet® communication protocol


/ Ariston Net ready for - Ariston Net embedded
/ Very good acoustic comfort thanks to the new optimized
silence

/ “AUTO function”, constant temperature for the maximum


thermic comfort
/ “Comfort Function”, instantaneous hot water, for 30’, after first
withdrawal, reducing waiting times

/ Best materials available to guarantee high reliability and very


long lifecycle
/ Boiler protection from water impurities accumulation
/ Anti-freezing systems preventing freezing and scale accumulation
/ With its IPX5D, the protection, against water jet streams
(only FF version)

400 (24CF, 24-30FF) 180 (24-30-32-35FF)


440 (30CF-32-35FF) 191(24-30CF)
770 (24-30CF, 32-35FF)
745 (24-30FF)

150
65 67 67 65 319 (24-30-32-35FF)
315 (24-30CF)

LEGEND

A: Central Heating Flow


B: Domestic Hot Water Outlet
C: Gas Inlet
D: Domestic Cold Water Inlet
E: Central Heating Return

70 /
24 / 30 / 32 / 35 CF / 24 / 30 FF

TECHNICAL DATA 24 CF 30 CF 24 FF 30 FF 32 FF 35 FF
Graph of boiler’s residual head
Models 32/35 POWER SPECIFICATIONS
mCE Models 24/30 Max/min nominal heat input(Hi) kW 25,8/11,0 29,5/13,0 25,8/11,0 30,0/13,0 32,5/15,0 34,5/15,0
6
Max/min nominal heat input (Hs) kW 28,7/12,2 32,8/14,4 28,7/12,2 33,3/14,4 36,1/16,7 38,3/16,7
5
Max/min nominal heat input for hot water (Hi) kW 27,0/11,0 30,5/13,0 25,8/11,0 30,0/13,0 34,5/15,0 34,5/15,0
4
Max/min nominal heat input for hot water (Hs) kW 30,0/12,2 33,9/14,4 28,7/12,2 33,3/14,4 38,3/16,7 38,3/16,7
3 Heat output: max/min kW 23,7/9,9 26,5/11,2 24,0/9,5 28,1/11,6 29,6/12,8 32,3/13,2
2 D.H.W. Heat output: max/min kW 25,0/10,2 27,9/11,9 23,6/10,0 27,4/11,9 32,2/14,0 32,2/14,0
Combustion efficiency (of flue gas) % 92,7 92,8 93,7 93,8 93,1 93,9
1
Gross efficiency of nominal heat input (60/80 °C) Hi/Hs % 91,9/82,8 89,9/81,0 93,1/83,8 93,6/84,3 91,1/82,0 93,6/84,3

0 100 200 300 400 500 600 700 800 900 1000 1100
Gross efficiency at 30 % at 47°C Hi/Hs % 91,2/82,1 89,7/80,8 93,3/84,0 93,7/84,4 89,8/80,9 92,6/83,4
flow rate l/h Gross efficiency at minimum power Hi/Hs % 90,2/81,2 86,5/77,9 86,7/78,1 93,7/84,4 85,0/76,5 88,2/79,4
Number of efficiency stars (Directive 92/42/EEC) stars ★★ ★★ ★★★ ★★★ ★★★ ★★★
Ma. heat loss to the casing (ΔT = 50°C) % 0,8 2,9 0,6 0,2 2 0,3
CF Version - Natural draught
Heat loss through the flue when burner on % 7,3 7,2 6,3 6,2 6,9 6,1
Heat loss through the flue when burner off % 0 ,4 0,4 0,4 0,4 0,4 0,4

EMISSIONS
Residual discharge head Pa - - 120 145 130 130
Minimun draw Pa 4,1 4,3 - - - -
FF Versions - Coaxial exhaust
Nox class class 2 2 3 3 3 3
180 Flue fumes temperature (G20) °C 116 125 117 110 125 112
CO2 content2 (G20) % 5,4 6,1 6,5 6,1 6,4 6,4
180 CO content (0 %02) ppm 54 44 60 111 141 159
105

O2 content2 (G20) % 10,8 9,5 8,8 9,5 9 9


Max capacity fumes (G20) kg/h 67,2 70,2 56,9 71,2 77,2 77,2
105

Excess air % 105 83 72 83 75 75


Ø60/100: up to 4m (24-28 kW) - 2m (32-35 kW)
Ø80/125: up to 11m (24-28 kW) - 8 m (32 kW) - 7 m (35 kW))
HEATING CIRCUIT
FF Versions - Twin pipe exhaust 180
Expansion vessel pre-charged pressure Mpa (bar) 0,1 (1) 0,1 (1) 0,1 (1) 0,1 (1) 0,1 (1) 0,1 (1)
Maximum central heating circuit pressure Mpa (bar) 0,3 (3) 0,3 (3) 0,3 (3) 0,3 (3) 0,3 (3) 0,3 (3)
180
334

Expansion vessel capacity l 8 8 8 8 8 8


243

Central heating temperature: max/min °C 82/35 82/35 82/35 82/35 82/35 82/35
334
243

DOMESTIC HOT WATER CIRCUIT


Domestic hot water temperature max/min °C 60/36 60/36 60/36 60/36 60/36 60/36
Ø80/80: up to 45m (24kW) - 50m (28kW) - 33m (32 kW) - Specific flow rate of domestic hot water
33m (35 kW) l/min 11,8 13,2 11,2 13,2 15,1 15,1
system (10 min. with ΔT=30°C) instant boilers
D.H.W. flow rate ΔT=25°C l/min 14,3 16 13,5 15,7 18,5 18,5
D.H.W. flow rate ΔT=35°C l/min 10,2 11,4 9,6 11,2 13,2 13,2
Hot water comfort stars (EN13203) stars ★★ ★★ ★★ ★★ ★★ ★★
D.H.W. minimum flow rate l/min <2 <2 1,7 1,7 1,7 1,7
Domestic hot water pressure max/min Mpa (bar) 0,7/0,1 (7/1) 0,7/0,1 (7/1) 0,7/0,1 (7/1) 0,7/0,1 (7/1) 0,7/0,1 (7/1) 0,7/0,1 (7/1)

ELECTRICAL
Power supply voltage/frequency V/Hz 220/50 220/50 220/50 220/50 220/50 220/50
Power consumption W 50 50 84 101 101 101
Minimum operating room temperature °C 5 5 5 5 5 5
Electric system grades of protection IP X5D X5D X5D X5D X5D X5D
Weight kg 27 28 31 32 30 31

CODE

3300850 3300852 3300851 3300853 3300854 3300855

For complete list of accessories see page 82

/ 71
CLAS X NEW

Compact wall-mounted conventional


boiler with AUTO function ENERGY CLASS
/ LCD panel
/ High-efficiency circulator pump with C
continuous modulation (model CF EU)
B
/ Configured for Ariston Net connectivity
/ Bridgenet® bus communication protocol
/ Configured for multi-zone and multi-
temperature temperature control
/ Configured for use with solar heating systems
/ AUTO and Comfort functions

/ Aluminium finned primary heat exchanger


/ Cold water inlet and heating return filters
/ Low NOx emissions < 56 mg/kWh (model CF
EU)

200 200
180
25

125
130
745

150
28

65 67 67 65
315
A B C D E

KEY

A \ System delivery Ø 3/4" gas


B \ Domestic hot water Ø 1/2" gas
C \ Gas inlet Ø 3/4" gas
D \ Domestic hot water inlet Ø 1/2” gas
E \ System return Ø 3/4" gas

72 /
24 CF EU / 28 CF EU / 24 CF NG / 24 / 28 FF

TECHNICAL DATA 24 CF EU 28 CF EU 24 CF NG 24 FF 28 FF
Boiler residual head
[mbar]
500 POWER SPECIFICATIONS
Max/min nominal calorific flow rate (Hi) kW 25,8/11 29,5/13 25,8/11 25,8/11 30/13
400
Max/min nominal calorific flow rate (Hs) kW 28,7/12,2 32,8/14,4 28,7/12,2 28,7/12,2 33,3/14,4
300 Domestic hot water max/min nominal calorific flow rate (Hi) kW 27/11 29,5/13 27/11 25,8/11 30/13
Domestic hot water max/min nominal calorific flow rate (Hs) kW 30/12,2 32,8/14,4 30/12,2 28,7/12,2 33,3/14,4
200
Max/min power output (80°C-60°C) kW 23,2/9,8 26,6/11,6 23,7/9,9 24/9,5 28,1/11,6
100 Domestic hot water max/min power output kW 24,3/9,9 26,6/11,7 25/10,2 23,6/10 27,4/11,9
Combustion efficiency (of flue gas) % 93,3 92,9 92,9 93,7 93,8
0
100 200 300 400 500 600 700 800 900 Nominal calorific flow rate efficiency (60/80°C) Hi/Hs % 90,1/81,1 90,2/81,2 91,9/82,8 93,1/83,8 93,6/84,3
[l\h] Efficiency at 30% at 47°C Hi/Hs % 89,9/81 90,3/81,3 91,2/81,2 93,3/84 93,7/84,4
Minimum calorific flow rate efficiency (60/80°C) Hi/Hs % 88,9/80,1 89,4/80,5 90,2/81,2 86,7/8,1 89,3/80,4
Efficiency rating (dir. 92/42/EEC) ★★ ★★ ★★ ★★★ ★★★
Sedbuk class classe D D D D D
Loss of burner gas when operating % 6,7 7,1 7,3 6,3 6,2

EMISSIONS
Available air pressure Pa - - - 120 145
NoX class class 6 6 2 3 3
Flue gas temperature (G20) (80°C-60°C) °C 111 119 116 117 110
CF versions - Natural draught
CO2 content (G20) (80°C-60°C) % -/- -/- 5,4 6,5 6,1
CO content (0%O2) (80°C-60°C) ppm 81/9 90/4 54 60 111
O2 content (G20) (80°C-60°C) % 10,4 10,1 10,8 6,5 9,5
Maximum flue gas flow (G20) (80°C-60°C) Kg/h 68,2 72,8 67,2 56,9 71,2
Excess air (80°C-60°C) % 98 93 105 72 83

HEATING CIRCUIT
Expansion chamber inflation pressure bar 1 1 1 1 1
Maximum heating pressure bar 3 3 3 3 3
Expansion chamber capacity l 6,5 6,5 6,5 6,5 6,5
Central heating temperature: max/min °C 82/35 82/35 82/35 82/35 35/82
Description N° of boilers per pallet
CLAS X 24 CF 14
CLAS X 28 CF 12 DOMESTIC HOT WATER CIRCUIT
Domestic hot water max/min temperature °C 60/36 60/36 60/36 60/35 60/35
Specific flow rate of domestic hot water (10 min - ΔT=30°C) l/min 12,2 13,2 11,8 11,2 13,2
Quantity of hot water ΔT=25°C l/min 14,6 15,8 14,3 13,5 15,7
Quantity of hot water ΔT=35°C l/min 10,5 11,3 10,2 9,6 11,2
Hot water comfort rating (EN13203) ★★★ ★★★ ★★ ★★ ★★
Hot water minimum flow rate l/min 2 2 2 2 2
Domestic hot water max pressure bar 7 7 7 7 7

ELECTRICAL
Power supply frequency/voltage V/Hz 230/50 230/50 230/50 220/50 220/50
Total electrical power absorbed W 52,1 52,1 78 108 131
Minimum ambient temperature for use °C 5 5 5 5 5
Protection level for the electrical appliance IP X4D X4D X4D X5D X5D
Weight kg 27 27 27 29 28

CODE

3301313 3301314 3300866 3300864 3300865

For complete list of accessories see page 82

/ 73
CLAS X SYSTEM
Wall-hung compact boiler, ready to use
with external DHW tank
/ Very high efficiency (up to 93,6%, 28FF)

/ Best enjoyable design of its category


/ High resolution LCD display with full text, touch interface and
intuitive menu

/ BusBridgeNet® communication protocol


/ Ariston Net ready for

/ “AUTO function”, constant temperature for the maximum


thermic comfort
/ The equipment allows the production of domestic hot water
with the connection of an external tank

/ Best materials available to guarantee high reliability and very


long lifecycle
/ Boiler protection from water impurities accumulation
/ Anti-freezing systems preventing freezing and scale
accumulation
/ With its IPX5D, the protection, against water jet streams

400 (24CF, 24-28FF) 180 (24-28-32FF)


440 (28CF, 32FF) 191 (24-28CF)
745 (24-28-32FF)
770 (24-28CF)

150
28

65 67 67 65 319 (24-28-32FF)
315 (24-28CF)
R

LEGEND

A: Central Heating Flow + Tank Inlet (CLAS X SYSTEM)


R: Tank return (CLAS X SYSTEM)
C: Gas Inlet
D: Domestic Cold Water Inlet
E: Central Heating Return

74 /
24 / 28 CF / 24 / 28 / 32 FF

TECHNICAL DATA 24 CF 28 CF 24 FF 28 FF 32 FF
Graph of boiler’s residual head
Model 32
Model 28 POWER SPECIFICATIONS
mCE Model 24
600 Max/min nominal heat input(Hi) kW 25,8/11,0 29,5/13,0 25,8/11,0 30,0/13,0 34,5/15,0
Max/min nominal heat input (Hs) kW 28,7/12,2 32,8/14,4 28,7/12,2 33,3/14,4 38,3/16,7
500
Max/min nominal heat input for hot water (Hi) kW 27,0/11,0 30,5/13,0 25,8/11,0 30,0/13,0 34,5/15,0
400
Max/min nominal heat input for hot water (Hs) kW 30,0/12,2 33,9/14,4 28,7/12,2 33,3/14,4 29,6/12,8
300 Heat output: max/min kW 23,7/9,9 26,5/11,2 24,0/9,5 28,1/11,6 32,3/13,2
200 D.H.W. Heat output: max/min kW 25,0/10,2 27,9/11,9 23,6/10,0 27,4/11,9 32,2/14,0
Combustion efficiency (of flue gas) % 92,7 92,8 93,7 93,8 93,1
100
Gross efficiency of nominal heat input (60/80 °C) Hi/Hs % 91,9/82,8 89,9/81,0 93,1/83,8 93,6/84,3 91,1/82,0
Gross efficiency at 30 % at 47°C Hi/Hs % 91,2/82,1 89,7/80,8 93,3/84,0 93,7/84,4 89,9/80,9
0 100 200 300 400 500 600 700 800 900 1000 1100
l/h Gross efficiency at minimum power Hi/Hs % 90,2/81,2 86,5/77,9 86,7/78,1 89,3/80,4 85,0/76,5
Number of efficiency stars (Directive 92/42/EEC) stars ★★ ★★ ★★★ ★★★ ★★★
Ma. heat loss to the casing (ΔT = 50°C) % 0,8 2,9 0,6 2
FF Versions - Coaxial exhaust Heat loss through the flue when burner on % 7,3 7,2 6,3 6,5 6,9
Heat loss through the flue when burner off % 0 ,4 0,4 0,4 0,4 0,4
180

180 EMISSIONS
Residual discharge head Pa - - 120 145 130
105

Minimun draw Pa 4,1 4,3 - - -


Nox class class 2 2 3 3 3
105

Ø60/100: up to 4m (24-28 kW) - 2m (32 kW) Flue fumes temperature (G20) °C 116 125 117 113 125
Ø80/125: up to 11m (24-28 kW) - 8 m (32 kW)
CO2 content2 (G20) % 5,4 6,1 6,5 6 6,4
FF Versions - Twin pipe exhaust 180 CO content (0 %02) ppm 54 44 60 111 141
O2 content2 (G20) % 10,8 9,5 8,8 9,7 9
180
Max capacity fumes (G20) kg/h 67,2 70,2 56,9 71,2 77,2
334 334

Excess air % 105 83 72 86 75


243 243

HEATING CIRCUIT
Expansion vessel pre-charged pressure Mpa (bar) 0,1 (1) 0,1 (1) 0,1 (1) 0,1 (1) 0,1 (1)
Ø80/80: up to 45m (24kW) - 50m (28kW) - 33m (32 kW) Maximum central heating circuit pressure Mpa (bar) 0,3 (3) 0,3 (3) 0,3 (3) 0,3 (3) 0,3 (3)
Expansion vessel capacity l 8 8 8 8 8
Central heating temperature: max/min °C 82/35 82/35 82/35 82/35 82/35

DOMESTIC HOT WATER CIRCUIT


Domestic hot water temperature (SYSTEM MOD.) max/min 60/40 60/40 60/40 60/40 60/40

ELECTRICAL
Power supply voltage/frequency V/Hz 220/50 220/50 220/50 220/50 220/50
Power consumption W 78 78 108 131 127
Minimum operating room temperature °C 5 5 5 5 5
Electric system grades of protection IP X5D X5D X5D X5D X5D
Weight kg 27 28 29 28 31

CODE

3300867 3300868 3300869 3300870 3300871

For complete list of accessories see page 82

/ 75
CARES X
Wall-hung compact boiler
/ Very high efficiency (up to 93,8%, 24FF)

/ LCD display and intuitive menu

/ Ariston Net ready for

/ Addition of a thermostatic mixing valve allows the connection


with a natural circulation solar water heater
/ The boiler is already equipped for the domestic hot water
production
/ Connection of on-off thermoregulation accessories allows the
heating programming for the whole week
/ Suitable for heating large spaces

/ Best materials available to guarantee high reliability and very


long lifecycle
/ Boiler protection from water impurities accumulation with the
addition of heating return filter
/ Anti-freezing systems preventing freezing and scale
accumulation
/ The external combustion analysis port allows easy check of
combustion quality

180 (24FF)
400 191 (24CF)
770 (24CF)
745 (24FF)

150
65 67 67 65 319 (24FF)
315 (24CF)
B

LEGEND

A: Central Heating Flow


B: Domestic Hot Water Outlet
C: Gas Inlet
D: Domestic Cold Water Inlet
E: Central Heating Return

76 /

You might also like