0% found this document useful (0 votes)
546 views

Tekna AKL Technical Data

The document describes the Tekna AKL Series solenoid dosing pump. It has a flow rate range from 0.4 to 110 l/h and can operate at back pressures up to 20 bar. The pump is powered by 100-240 Vac power and has a stroke rate ranging from 120 to 300 strokes per minute. It features a PVDF pump head and PTFE diaphragm, with an IP65 rated enclosure. The pump comes with installation kits for plumbing connections.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
546 views

Tekna AKL Technical Data

The document describes the Tekna AKL Series solenoid dosing pump. It has a flow rate range from 0.4 to 110 l/h and can operate at back pressures up to 20 bar. The pump is powered by 100-240 Vac power and has a stroke rate ranging from 120 to 300 strokes per minute. It features a PVDF pump head and PTFE diaphragm, with an IP65 rated enclosure. The pump comes with installation kits for plumbing connections.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

DOSING PUMP

TEKNA AKL SERIES – Solenoid Dosing Pump

Technical characteristics

• Flow rates: from 0.4 to 110 l/h


• Max back pressure: up to 20 bar
• Power supply:
• 100÷240 Vac - 50/60 Hz
• Stroke rate: from 120 to 300 strokes/minute
• Pump head:
• PVDF
• Diaphragm: PTFE
• External Enclosure: PP reinforced with fiber glass
protection degree IP65
• Manually priming valve
• Installation kit: Included

Seko Tekna AKL Series is an analogic dosing pump with constant flow rate, which is manually adjustable by a knob mounted on
the front panel, in addition there is the level control input than the Tekna AKS.
The flow rate has two frequency ranges:
• 0÷20 % of max flow rate
• 0÷100% of max flow rate

With only 5 sizes that pump can cover a wide range of performances, having a flow rate range from 0.4 to 110 l/h and a back
pressure from 0.1 to 20 bar. The power supply is 100÷240 Vac – 50/60 Hz therefore the same pump can operate with different
supply voltage, moreover the model AKL603 have the possibility for 24÷48 Vac power supply.
The standard pump head is in PVDF, therefore high chemical compatibility with several liquids end but is available in PVC as
well, on request.
All Tekna series are equipped with a manually priming pump for the start up.
The pump is furnished with a complete standard installation kit, which includes: PVDF foot filter and injection valve, PVC suction
tube, PE delivery tube. Moreover is available an installation kit in PVDF-T, on request.

Technical data can be changed without notice.


1 of 4 TD_Tekna_AKL_Series_rev.0.2
DOSING PUMP
TEKNA AKL SERIES – Solenoid Dosing Pump
PUMP KEY CODE Ci el d 1 Ci el d 2 Ci el d 3 Ci el d 4 Ci el d 5 Ci el d 6 Ci el d 7
AYL 800 N H H 0 000

Ci el d 1 model
Ci el d 2 hydraulics
Ci el d 3 power supply
Ci el d 4 liquid end
Ci el d 5 installation kit
Ci el d 6 seals
Ci el d 7 customization

Ci el d 1 model Analog
AYL

Ci el d 2 hydraulics bar l/h stroke/1' ml/stroke tubing Ø consumption


500 20 0,4 0,06
16 0,8 0,11 i n - 4/6
120 15 W
10 1,2 0,17 out - 4/7
6 1,5 0,21
600 20 2,5 0,3D
18 3 0,42 i n - 4/6
120 19 W
14 4,2 0,D8 out - 4/7
8 7 0,97
603 12 4 0,42
10 5 0,D2 i n - 4/6
160 22 W
8 6 0,63 out - 4/6
2 8 0,83
800 16 7 0,39
10 10 0,DD i n - 4/6
300 33 W
5 15 0,83 out - 4/6
1 18 1,00
803 5 20 1,11
4 32 1,78 i n - 8/12
300 37 W
2 62 3,44 out - 8/12
0 110 6,11

Ci el d 3 power supply
N 100÷240 Va c

Ci el d 4 liquid end Body Connections Balls Diaphragm


H PVDC PVDC Cera mi c PTCE
A PVDC PVDC Cera mi c PTCE
I AISI316L AISI316L PTCE
A Pump head with automatic degassing valve. Only for 603 and 800 series

Ci el d 5 installation kit
H PVDC
P PVDC-T

Ci el d 6 seals
0 CPM
1 EPDM
2 El a s tomer Cree

Ci el d 7 customization
000 s ta nda rd

Technical data can be changed without notice.


2 of 4 TD_Tekna_AKL_Series_rev.0.2
DOSING PUMP
TEKNA AKL SERIES – Solenoid Dosing Pump
HYDRAULIC CHARACTERISTICS

Frequency Stroke Connection


Pressure Flow [mm]
Consumption [W]
Pump Model max capacity Power supply
[bar] Rate [l/h]
[stroke/min] [cc/stroke]
Suction Discharge Min Max
20 0,4 0,06
16 0,8 0,11
AKL500N 120 4/6 4/7 100÷240 Vac 13,0 15,0
10 1,2 0,17
6 1,5 0,21
20 2,5 0,35
18 3,0 0,42
AKL600N 120 4/6 4/7 100÷240 Vac 14,0 19,0
14 4,2 0,58
8 7,0 0,97
12 4,0 0,42
10 5,0 0,52
AKL603N 160 4/6 4/6 100÷240 Vac 17,0 22,0
8 6,0 0,63
2 8,0 0,83
16 7,0 0,39
10 10,0 0,56
AKL800N 300 4/6 4/6 100÷240 Vac 22,0 33,0
5 15,0 0,83
1 18,0 1,00
5 20,0 1,11
4 32,0 1,78
AKL803N 300 8/12 8/12 100÷240 Vac 29,0 37,0
2 62,0 3,44
0 110,0 6,11
The Pressure Data in the table refer to the measured parameters on the plant, including the use of SEKO STANDARD injection fitting.

*Minimum consumption at 0 bar of back pressure (Patented)

DIMENSIONS

500 - 600 - 603 - 800 803

Technical data can be changed without notice.


3 of 4 TD_Tekna_AKL_Series_rev.0.2
DOSING PUMP
TEKNA AKL SERIES – Solenoid Dosing Pump
INSTALLATION KIT PVDF PVDF-T
PVDF foot filter ●
PVDF injection valve ●
PVDF-T foot filter ●
PVDF-T Injection valve ●
PVC suction tube (4 m) ●
PE delivery tube (2 m) ●
Wall and base fixing bracket ●

22

20

18

16

14
Pressure [bar]

12 AKL500N

10 AKL600N
AKL603N
8
AKL800N
6

0
0 5 10 15 20
Flow rate [l/h]

4
Pressure [bar]

3
AKL803N
2

0
0,0 20,0 40,0 60,0 80,0 100,0 120,0
Flow rate [l/h

Technical data can be changed without notice.


4 of 4 TD_Tekna_AKL_Series_rev.0.2