Open navigation menu
Close suggestions
Search
Search
en
Change Language
Upload
Sign in
Sign in
Download free for days
0 ratings
0% found this document useful (0 votes)
92 views
REA200 N
Uploaded by
Muhammad Lathieful Haq
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download now
Download
Save REA200n For Later
Download
Save
Save REA200n For Later
0%
0% found this document useful, undefined
0%
, undefined
Embed
Share
Print
Report
0 ratings
0% found this document useful (0 votes)
92 views
REA200 N
Uploaded by
Muhammad Lathieful Haq
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download now
Download
Save REA200n For Later
Carousel Previous
Carousel Next
Download
Save
Save REA200n For Later
0%
0% found this document useful, undefined
0%
, undefined
Embed
Share
Print
Report
Download now
Download
You are on page 1
/ 4
Search
Fullscreen
Nl Protection Relays A Protection Class of its Own Combined IDMTL Overcurrent & Earth Fault Relay . REA200nMH Protection Relays Represents a legacy of design and development, specializing in power management and power NA in solutions and its core expertise, electrical protection relays. The MH Protection Relays has its heritage dated since 1981 where, designed by Mun Hean and OEM by Kasuga of Japan, developed a range of electronic relays that dominated the market for decades. The range of relays were marketed under the brand name "Kasuga-MH" Today, with its own R&D wing, Mun Hean Technology Pte Ltd, MH continues this tradition. Anchored on the exclusive MTB fault indication system, we proudly bring to you this state-of-the-art protection relay series that is truly, A Protection Class of its Own. Features roprocessor-based with highest accuracy - Mechanical Trip Button (MTB) fault indication system - No requirement for auxiliary power supply for fault indication - Safeguard against automatic reset before fault rectification - Curve selection in accordance with ANSI, IAC, IEC, 1.3/10 ® Normally Inverse (NI) © Very Inverse (VI) © Extremely Inverse (El) © Short Time Inverse (STI) ‘* Moderate Inverse (MI) - Trip value recording (4-memory) - Date & time stamping for tripping - Integrated surge arrester against transient overvoltages - High set mode is incorporated for instantaneous protection - Tamper-proof design for settings protection - Serial interface RS485 for Modbus RTU communication (op' - Type tested* for EMC compliance in ace. with IEC 61000 - High immunity to electrical interference (tested to 2.5GHz) ~ Type tested in acc. with IEC 60255* * Type test report issued by independent testing laboratory is available upon request. Setting Display Instantaneous Indicator Mode 78 Fault Indication Latch Relay / sags Test Button (woos) paDex) ‘Menu Navigation KeysTechnical Data Characteristics Power supply AC / DC 85 - 265V (other voltages available on request) Operating frequency S0/60H2 Earth Fault setting 2.5056 (0.1% per step) Overcurrent setting 20 - 200% (3% per step) Time Multiplier Overcurrent / Earth Fault IOMTL 0.03 - 2.0 (IEC, 1.3), 0.3 - 20.0 (ANSI, 1AC) Time setting range (OTL) 0.03- 20sec Instantaneous Mode (High set) 2-10 * setting current Pick-up current. 100 - 115% of the setting current Reset current value 90% of the operating value Operating and storage temperature range (Operating -20°C to 55°C Storage and transit -20°C to 65°C Relative humidity (IEC 60068-2-30) 95% at 40°C Degree of protection (IEC 60529) 1P52, Voltage withstand (IEC 60255-5) 2kVrms for 1 min between all case terminals connected together and the case earth terminal 2kVrms for 1 min between independent circuit including contact circuits Overcurrent withstand 207 | rues for 3 sec (100A-0/C, 20A-E/F) Power Consumption ‘Approximately 2VA Operational life expectancy Electrical: > 1 x 10° operations Output contact Mechanical: > 5x 10* operations AC250V 5A Optional output contact 2 separate contacts - AC240V SA, DC24V SA - E/F & O/C indication Communication : 88485 LED status indication (Normal operation) (Fault current detected) Safety feature Mechanical Trip Button (MTB) Housing material ‘ABS resin complying with UL94VO Unit weight Approximately 600g ‘Compliance with standards IEC/EN 60755 General rules for residual-current protection devices TEC/EN 6100-42 _ | Electrostatic-discharge immunity test TEC/EN 61000-4-3 _[Radiated, radio-frequency, electromagnetic field immunity test (type tested to 2.5GHz) TEC/EN 61000-4-4 _ [Electrical fast transient/burst immunity test TEC/EN 6100-45 _ [Surge immunity test TEC/EN 6100-46 | Immunity to conducted disturbances, Induced by radio-frequency fields TEC/EN 60255-1 ‘Measuring relay and protection equipment TEC/EN 60255-5 Insulation coordination for measuring relays and protection equipment - Requirement and tests TEC/EN 6472-2 Dimensions 96 | 22 Low voltage switchgear and control gear, Part 2: Circuit breakers, Annex M and J s0505 M1...Characteristics Curve Time Current Character accordance with IEC 60255 PERATING TE (ee) ‘OPERATING TEs Connection Diagram MOBO MC About MTB Fault Indication System MTB, or Mechanical Trip Button is a fault indication system incorporated in advanced protection relaying for electrical power networks. The MTB does not require auxiliary supply to provide a fault indication. The MTB is designed to prevent power circuits from re-energising before AUX.POWER a fault is completely rectified. This is an essential AGIDC85~265V safety feature which protection relays using electrical latching mechanisms are not able to Authorized Dealer:
You might also like
ROA207 N
PDF
No ratings yet
ROA207 N
4 pages
Catalogue Relay bảo vệ kết hợp OC EF MUN HEAN
PDF
No ratings yet
Catalogue Relay bảo vệ kết hợp OC EF MUN HEAN
32 pages
MH Relay General Brochure 2015 - LR
PDF
No ratings yet
MH Relay General Brochure 2015 - LR
16 pages
Mikro Cat 2015
PDF
No ratings yet
Mikro Cat 2015
74 pages
Mikro Cat 2015
PDF
No ratings yet
Mikro Cat 2015
74 pages
L&T Relay Brochure
PDF
100% (1)
L&T Relay Brochure
32 pages
mc61c PDF
PDF
No ratings yet
mc61c PDF
32 pages
96 RSN200 PDF
PDF
33% (3)
96 RSN200 PDF
6 pages
(HG) MCCB (HGP) Leaflet en 2019.01
PDF
No ratings yet
(HG) MCCB (HGP) Leaflet en 2019.01
10 pages
MJT314 Relay
PDF
100% (1)
MJT314 Relay
4 pages
Numerical Relays Catalogue
PDF
100% (1)
Numerical Relays Catalogue
31 pages
Abb Racid
PDF
No ratings yet
Abb Racid
8 pages
DPR e
PDF
No ratings yet
DPR e
19 pages
MCC GG
PDF
No ratings yet
MCC GG
20 pages
Racid in
PDF
No ratings yet
Racid in
8 pages
DC Switchgear
PDF
No ratings yet
DC Switchgear
10 pages
Midos: Type MCGG 22, 42, 52, 53, 62, 63 & 82 Overcurrent Relay For Phase and Earth Faults
PDF
No ratings yet
Midos: Type MCGG 22, 42, 52, 53, 62, 63 & 82 Overcurrent Relay For Phase and Earth Faults
14 pages
MCGG - 22 32 62 Manual
PDF
No ratings yet
MCGG - 22 32 62 Manual
14 pages
MCGG Ocr
PDF
No ratings yet
MCGG Ocr
14 pages
MCGG
PDF
100% (1)
MCGG
14 pages
MM-30 Relay
PDF
No ratings yet
MM-30 Relay
32 pages
MK2200L Manual
PDF
100% (1)
MK2200L Manual
46 pages
Session 2
PDF
No ratings yet
Session 2
26 pages
Type MMCO Microprocessor Time Overcurrent Relay: Application
PDF
No ratings yet
Type MMCO Microprocessor Time Overcurrent Relay: Application
4 pages
Digi Pro
PDF
No ratings yet
Digi Pro
32 pages
Mitsubishi ACB Air Circuit Breaker
PDF
No ratings yet
Mitsubishi ACB Air Circuit Breaker
68 pages
Info - Mitsubishi LV Acb - Ae-Ss and Ae-Sh
PDF
No ratings yet
Info - Mitsubishi LV Acb - Ae-Ss and Ae-Sh
68 pages
Product Data Sheet: Earth-Leakage Relay RH99M With Manual Reset - 0.03..30 A - 0..4.5 S - 130 V
PDF
No ratings yet
Product Data Sheet: Earth-Leakage Relay RH99M With Manual Reset - 0.03..30 A - 0..4.5 S - 130 V
2 pages
R37QRG000152 CSDPR-V2-500-C2 QRG
PDF
No ratings yet
R37QRG000152 CSDPR-V2-500-C2 QRG
2 pages
Vigirex 56173
PDF
No ratings yet
Vigirex 56173
3 pages
Type RXTCS: Trip Circuit Supervision Relay
PDF
No ratings yet
Type RXTCS: Trip Circuit Supervision Relay
6 pages
Overcurrent / Ground Fault Protection: MPRB-99-1.0-GF
PDF
No ratings yet
Overcurrent / Ground Fault Protection: MPRB-99-1.0-GF
19 pages
TS01 ING R0 U MLEs PLS Ts - V2
PDF
No ratings yet
TS01 ING R0 U MLEs PLS Ts - V2
6 pages
2501-NXA-ACB-Catalog
PDF
No ratings yet
2501-NXA-ACB-Catalog
113 pages
Earth Fault Monitoring Relays: Operating Instructions
PDF
No ratings yet
Earth Fault Monitoring Relays: Operating Instructions
4 pages
Digital Protective Relays
PDF
100% (3)
Digital Protective Relays
34 pages
Mc31a Rev5
PDF
No ratings yet
Mc31a Rev5
33 pages
Catalog HYUNDAI HGMP (E)
PDF
No ratings yet
Catalog HYUNDAI HGMP (E)
33 pages
9500100990
PDF
No ratings yet
9500100990
6 pages
Legrand PBL Apr 2025
PDF
No ratings yet
Legrand PBL Apr 2025
120 pages
Megawin: Numerical Over Current & Earth Fault Relay
PDF
100% (6)
Megawin: Numerical Over Current & Earth Fault Relay
16 pages
Manual Hi-Lo CO PDF
PDF
No ratings yet
Manual Hi-Lo CO PDF
7 pages
MJT314
PDF
No ratings yet
MJT314
4 pages
Dema-Mcr & MVR Protection Relay
PDF
100% (1)
Dema-Mcr & MVR Protection Relay
21 pages
Schneider Electric_VigiPacT_56173
PDF
No ratings yet
Schneider Electric_VigiPacT_56173
5 pages
Mk1000a Catalogue
PDF
No ratings yet
Mk1000a Catalogue
2 pages
Re17Lamw: Product Data Sheet
PDF
No ratings yet
Re17Lamw: Product Data Sheet
6 pages
Operating Instructions: STAR LIFTKET - Electric Chain Hoists
PDF
No ratings yet
Operating Instructions: STAR LIFTKET - Electric Chain Hoists
40 pages
EcoStruxure™ Control Expert - UNYSPUEFUV1X
PDF
No ratings yet
EcoStruxure™ Control Expert - UNYSPUEFUV1X
2 pages
DTS617/DTB617 Deadbreak Bolted Tee Connector: Power Systems Installation Instruction
PDF
No ratings yet
DTS617/DTB617 Deadbreak Bolted Tee Connector: Power Systems Installation Instruction
10 pages
Simatic Industrial PC Simatic Rack PC 847B
PDF
No ratings yet
Simatic Industrial PC Simatic Rack PC 847B
38 pages