0% found this document useful (0 votes)
82 views

SDC / VSD: Industrial Boosters

The document describes industrial booster sets with automatic operation consisting of up to 6 pumps on a common baseplate. It provides details on the construction, applications, technical data, and performance tables for SDC1 models with operating pressures ranging from 85-220 mWC and flows of 18-20 m3/h. Pumps are controlled by contact manometers in fixed speed regulation units or analog pressure sensors in variable speed regulation units to maintain constant pressure.

Uploaded by

Svetla Nikolova
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
82 views

SDC / VSD: Industrial Boosters

The document describes industrial booster sets with automatic operation consisting of up to 6 pumps on a common baseplate. It provides details on the construction, applications, technical data, and performance tables for SDC1 models with operating pressures ranging from 85-220 mWC and flows of 18-20 m3/h. Pumps are controlled by contact manometers in fixed speed regulation units or analog pressure sensors in variable speed regulation units to maintain constant pressure.

Uploaded by

Svetla Nikolova
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 56

SDC / VSD

Industrial
Boosters

CONSTRUCTION
MOTOR
Pressure boosting sets with automatic operation, consisting of up to
6 pumps on a common baseplate, with suction and delivery valves, 2-pole induction motors, 50 Hz, n=2900 rpm
and non-return valves, (suction and delivery manifolds in multi-pump Three-phase 230/400 V, 400/690 V ±10%
units), contact manometer in fixed speed regulation (SDC) units, analog Insulation class F
pressure sensor in variable speed regulation (VSD) units, pressure gauge, Protection IP54
float switch, special connector in 1-pump configuration, and control Constructed in accordance with IEC 60034
panel as fixed speed (SDC), and variable speed (VSD). Other voltages and frequencies on request

Suction and delivery manifolds are in AISI 304, up to DN100 sites, and Designation
electro-galvanized over DN100 sizes. SDC 4 / XVM 90-4

The unit includes one pressure gauge and adjustable differential pressure Pump Type
regulator as contact manometer in SDC execution, analog pressure Number of pumps in the unit
sensor in VSD execution. Fixed speed regulation with
Wye-Delta Starting control panel (SDC)
APPLICATIONS
VSD - 3 / XVM 90-4
- Water supply
- Sprinkling Pump Type
- Fİre fighting Number of pumps in the unit
- Irrigation and spraying Variable Speed Regulation
- Pumping water from wells and out of low lying tanks. with VSD control panel

TECHNICAL DATA
- Main connection
1 ~ 230 V / 50 Hz,
3 ~ 400 V / 50 Hz,
3 ~ 400 V / 690 V / 50 Hz,
- Suction head max. 5 m
- Inlet pressure max. 8 bar
- Fluid temperature +5°C to 110°C
- Operating pressure max. 25 bar
- Differential pressure regulator, contact manometer, 2-20 bar
- Analog sensor setting range 2-25 bar
- Protection IP54

867
SDC
Wye-Delta Pump Controllers

Panel Specifications

This equipment enables automatic or manual management of booster • Signal lamp for phase fault.
pumps. Pumps are controlled by the controller to remain constant pressure. • Signal lamp for low level.
• Signal lamps for pump run and pump fault.
• Pumps are controlled by star/delta circuits. • Dry contacts for each pump to scada or building management system.
• Mains input 3 ~ 50/60Hz 400V ±5%; • Auto-change function. Pumps can be change in interval times.
• 24VDC power supply for command circuits. • Equal aging function. In automatic mode, start order is changed by the
• Contactors are sized to AC-23 smart relay.
• Motor overload circuit breaker with high cutout capacity. • Following parameters can be controlled at display of smart relay on door.
• General disconnector with door lock. - Pressure,
• IP55 protection class. - Pressure transmitter ranges,
• System controlled by 0-10 V pressure transmitter - Work-hours of pumps
• Whole system can be enable/disable with dry contact. (external start)
• Each pump has a MAN-0-AUTO selector switch. In manual mode, pumps
can be controlled by start/stop buttons. In automatic mode pumps are
controlled by smart relay to remain constant the pressure.

868
VSD
Frequency Converted Pump Controllers

Panel Specifications

This equipment enables automatic or manual management of pumps. • Following parameters can be monitored at HMI. o Actual Pressure,
Pumps are controlled by frequency converter to remain constant the o Actual frequency, o Current o Power o Moment o Temperature, o
pressure or differential pressure. Assembled in painted sheet steel housing Pressure, current, frequency trends. Functions
with IP55 protection class. • Pumps are controlled by frequency converter.
• Selectable modes of operation. System can be used for circulation or
Electrical Features, booster pumps.
• Mains input 3 ~ 50/60Hz 400V ±5%; • In automatic mode, pumps are started by frequency converter. In this
• Contactors are sized to AC-23 way the pressure peaks are prevented. In this manner maximum energy
• Motor overload circuit breakers with high cutout capacity. saving is achieved.
• General disconnector with door lock. • Each pump can be controlled with dry contact pressure switch in manual
• Metal chasing. mode. Each pump has a DOL or STAR-DELTA circuit to operate without
• IP55 protection class. frequency inverter.
• Signal lamps for phase fault, low level. • Whole system can be enable/disable with dry contact for remote control.
• Signal lamps for pump run and pump fault. (external start)
• Dry contacts for each pump for scada or building management system • Each pump has a MAN-0-AUTO selector switch. In manual mode, pumps
• Board has a colorful HMI.(Human Machine Interface). can be controlled by pressure switch. In automatic mode pumps are
Following parameters can be controlled at HMI. controlled by frequency converter to remain constant the pressure.
- Pressure o Auxiliary pump start frequency, • Auto change function: Pumps can be change in interval times.
- Auxiliary pump stop frequency, • Equal aging function: In automatic mode, start order is changed by
- Auxiliary pump Start delay time, frequency converter.
- Auxiliary pump Stop delay time, • Sleep and wake-up functions for energy saving.
- Sleep frequency, sleep delay time, wake-up deviation
- Auto change interval,
- P, I, D parameters.
- Pressure transmitter ranges,
- Motor current, voltage, rpm etc.
869
VSD
Frequency Converted Pump Controllers

Panel Specifications

System Parameters

Actual values can be monitor Pressure, current, Frequency curves.

Pumps and system status

870
SDC1
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC1 XVM 15-10 3 400 11 15 18 105-125 2” 2”
SDC1 XVM 15-12 3 400 11 15 18 125-145 2” 2”
SDC1 XVM 15-14 3 400 11 15 18 145-165 2” 2”
SDC1 XVM 15-16 3 400 15 20 18 170-190 2” 2”
SDC1 XVM 15-17 3 400 15 20 18 180-200 2” 2”

SDC1 XVM 20-8 3 400 11 15 20 85-105 2” 2”


SDC1 XVM 20-10 3 400 11 15 20 110-130 2” 2”
SDC1 XVM 20-12 3 400 15 20 20 135-155 2” 2”
SDC1 XVM 20-14 3 400 15 20 20 160-180 2” 2”
SDC1 XVM 20-16 3 400 18,5 25 20 185-205 2” 2”
SDC1 XVM 20-17 3 400 18,5 25 20 200-220 2” 2”

871
SDC1
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC1 XVM 32-5-2 3 400 11 15 32 55-75 DN 65 DN 65
SDC1 XVM 32-5 3 400 11 15 32 60-80 DN 65 DN 65
SDC1 XVM 32-6-2 3 400 11 15 32 70-90 DN 65 DN 65
SDC1 XVM 32-6 3 400 11 15 32 75-95 DN 65 DN 65
SDC1 XVM 32-7-2 3 400 15 20 32 85-105 DN 65 DN 65
SDC1 XVM 32-7 3 400 15 20 32 90-110 DN 65 DN 65
SDC1 XVM 32-8-2 3 400 15 20 32 100-120 DN 65 DN 65
SDC1 XVM 32-8 3 400 15 20 32 105-125 DN 65 DN 65
SDC1 XVM 32-9-2 3 400 18,5 25 32 115-135 DN 65 DN 65
SDC1 XVM 32-9 3 400 18,5 25 32 120-140 DN 65 DN 65
SDC1 XVM 32-10-2 3 400 18,5 25 32 130-150 DN 65 DN 65
SDC1 XVM 32-10 3 400 18,5 25 32 135-155 DN 65 DN 65
SDC1 XVM 32-11-2 3 400 22 30 32 145-165 DN 65 DN 65
SDC1 XVM 32-11 3 400 22 30 32 150-170 DN 65 DN 65
SDC1 XVM 32-12-2 3 400 22 30 32 155-175 DN 65 DN 65
SDC1 XVM 32-12 3 400 22 30 32 165-185 DN 65 DN 65
SDC1 XVM 32-13-2 3 400 30 40 32 170-190 DN 65 DN 65
SDC1 XVM 32-13 3 400 30 40 32 180-200 DN 65 DN 65
SDC1 XVM 32-14-2 3 400 30 40 32 190-210 DN 65 DN 65

SDC1 XVM 45-3-2 3 400 11 15 45 45-60 DN 80 DN 80


SDC1 XVM 45-3 3 400 11 15 45 55-70 DN 80 DN 80
SDC1 XVM 45-4-2 3 400 15 20 45 65-85 DN 80 DN 80
SDC1 XVM 45-4 3 400 15 20 45 75-95 DN 80 DN 80
SDC1 XVM 45-5-2 3 400 18,5 25 45 85-105 DN 80 DN 80
SDC1 XVM 45-5 3 400 18,5 25 45 95-115 DN 80 DN 80
SDC1 XVM 45-6-2 3 400 22 30 45 110-130 DN 80 DN 80
SDC1 XVM 45-6 3 400 22 30 45 120-140 DN 80 DN 80
SDC1 XVM 45-7-2 3 400 30 40 45 130-150 DN 80 DN 80
SDC1 XVM 45-7 3 400 30 40 45 140-160 DN 80 DN 80
SDC1 XVM 45-8-2 3 400 30 40 45 150-170 DN 80 DN 80
SDC1 XVM 45-8 3 400 30 40 45 155-175 DN 80 DN 80
SDC1 XVM 45-9-2 3 400 30 40 45 170-190 DN 80 DN 80
SDC1 XVM 45-9 3 400 37 50 45 180-200 DN 80 DN 80
SDC1 XVM 45-10-2 3 400 37 50 45 190-210 DN 80 DN 80

872
SDC1
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC1 XVM 64-2-1 3 400 11 15 64 30-45 DN 100 DN 100
SDC1 XVM 64-2 3 400 11 15 64 35-55 DN 100 DN 100
SDC1 XVM 64-3-2 3 400 15 20 64 45-65 DN 100 DN 100
SDC1 XVM 64-3-1 3 400 15 20 64 50-70 DN 100 DN 100
SDC1 XVM 64-3 3 400 18,5 25 64 60-80 DN 100 DN 100
SDC1 XVM 64-4-2 3 400 18,5 25 64 65-85 DN 100 DN 100
SDC1 XVM 64-4-1 3 400 22 30 64 75-95 DN 100 DN 100
SDC1 XVM 64-4 3 400 22 30 64 80-100 DN 100 DN 100
SDC1 XVM 64-5-2 3 400 30 40 64 90-110 DN 100 DN 100
SDC1 XVM 64-5-1 3 400 30 40 64 95-115 DN 100 DN 100
SDC1 XVM 64-5 3 400 30 40 64 105-125 DN 100 DN 100
SDC1 XVM 64-6-2 3 400 30 40 64 115-135 DN 100 DN 100
SDC1 XVM 64-6-1 3 400 37 50 64 120-140 DN 100 DN 100
SDC1 XVM 64-6 3 400 37 50 64 125-145 DN 100 DN 100
SDC1 XVM 64-7-2 3 400 37 50 64 135-155 DN 100 DN 100
SDC1 XVM 64-7-1 3 400 37 50 64 140-160 DN 100 DN 100
SDC1 XVM 64-7 3 400 45 60 64 150-170 DN 100 DN 100
SDC1 XVM 64-8-2 3 400 45 60 64 155-175 DN 100 DN 100
SDC1 XVM 64-8-1 3 400 45 60 64 165-185 DN 100 DN 100

SDC1 XVM 90-2-2 3 400 11 15 90 25-40 DN 100 DN 100


SDC1 XVM 90-2 3 400 15 20 90 40-55 DN 100 DN 100
SDC1 XVM 90-3-2 3 400 18,5 25 90 50-65 DN 100 DN 100
SDC1 XVM 90-3 3 400 22 30 90 60-80 DN 100 DN 100
SDC1 XVM 90-4-2 3 400 30 40 90 70-90 DN 100 DN 100
SDC1 XVM 90-4 3 400 30 40 90 85-105 DN 100 DN 100
SDC1 XVM 90-5-2 3 400 37 50 90 95-115 DN 100 DN 100
SDC1 XVM 90-5 3 400 37 50 90 110-130 DN 100 DN 100
SDC1 XVM 90-6-2 3 400 45 60 90 120-140 DN 100 DN 100
SDC1 XVM 90-6 3 400 45 60 90 130-150 DN 100 DN 100

873
SDC1
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC1 WTX 50-200/9,2 3 400 9,2 12,5 50 40-47 DN80 DN 65
SDC1 WTX 50-200/11 3 400 11 15 60 40-50 DN80 DN 65
SDC1 WTX 50-200/15 3 400 15 20 60 54-62 DN80 DN 65

SDC1 WTM 40-250/9,2 3 400 9,2 12,5 40 45-58 DN 80 DN 65


SDC1 WTM 40-250/11 3 400 11 15 40 50-65 DN 80 DN 65
SDC1 WTM 40-250/15 3 400 15 20 40 60-80 DN 80 DN 65

SDC1 WTM 50-200/9,2 3 400 9,2 12,5 75 30-45 DN 80 DN 65


SDC1 WTM 50-200/11 3 400 11 15 75 35-50 DN 80 DN 65
SDC1 WTM 50-250/15 3 400 15 20 75 45-60 DN 80 DN 65
SDC1 WTM 50-250/18,5 3 400 18,5 25 75 55-70 DN 80 DN 65
SDC1 WTM 50-250/22 3 400 22 30 85 60-80 DN 80 DN 65

SDC1 WTM 65-250/22 3 400 22 30 120 40-55 DN 100 DN 80


SDC1 WTM 65-250/30 3 400 30 40 120 60-70 DN 100 DN 80
SDC1 WTM 65-250/37 3 400 37 50 120 70-85 DN 100 DN 80

SDC1 WTM 80-160/15 3 400 15 20 190 20-30 DN 125 DN 100


SDC1 WTM 80-160/18,5 3 400 18,5 25 200 25-35 DN 125 DN 100
SDC1 WTM 80-200/22 3 400 22 30 190 30-42 DN 125 DN 100
SDC1 WTM 80-200/30 3 400 30 40 200 42-55 DN 125 DN 100
SDC1 WTM 80-250/37 3 400 37 50 190 45-65 DN 125 DN 100
SDC1 WTM 80-250/45 3 400 45 60 190 55-75 DN 125 DN 100
SDC1 WTM 80-250/55 3 400 55 75 190 70-85 DN 125 DN 100

874
SDC2
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC2 XVM 15-10 3 400 2 x 11 2 x 15 2 x 18 105-125 3” 2½”
SDC2 XVM 15-12 3 400 2 x 11 2 x 15 2 x 18 125-145 3” 2½”
SDC2 XVM 15-14 3 400 2 x 11 2 x 15 2 x 18 145-165 3” 2½”
SDC2 XVM 15-16 3 400 2 x 15 2 x 20 2 x 18 170-190 3” 2½”
SDC2 XVM 15-17 3 400 2 x 15 2 x 20 2 x 18 180-200 3” 2½”

SDC2 XVM 20-8 3 400 2 x 11 2 x 15 2 x 20 85-105 3” 3”


SDC2 XVM 20-10 3 400 2 x 11 2 x 15 2 x 20 110-130 3” 3”
SDC2 XVM 20-12 3 400 2 x 15 2 x 20 2 x 20 135-155 3” 3”
SDC2 XVM 20-14 3 400 2 x 15 2 x 20 2 x 20 160-180 3” 3”
SDC2 XVM 20-16 3 400 2 x 18,5 2 x 25 2 x 20 185-205 3” 3”
SDC2 XVM 20-17 3 400 2 x 18,5 2 x 25 2 x 20 200-220 3” 3”

875
SDC2
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC2 XVM 32-5-2 3 400 2 x 11 2 x 15 2 x 32 55-75 DN 100 DN 100
SDC2 XVM 32-5 3 400 2 x 11 2 x 15 2 x 32 60-80 DN 100 DN 100
SDC2 XVM 32-6-2 3 400 2 x 11 2 x 15 2 x 32 70-90 DN 100 DN 100
SDC2 XVM 32-6 3 400 2 x 11 2 x 15 2 x 32 75-95 DN 100 DN 100
SDC2 XVM 32-7-2 3 400 2 x 15 2 x 20 2 x 32 85-105 DN 100 DN 100
SDC2 XVM 32-7 3 400 2 x 15 2 x 20 2 x 32 90-110 DN 100 DN 100
SDC2 XVM 32-8-2 3 400 2 x 15 2 x 20 2 x 32 100-120 DN 100 DN 100
SDC2 XVM 32-8 3 400 2 x 15 2 x 20 2 x 32 105-125 DN 100 DN 100
SDC2 XVM 32-9-2 3 400 2 x 18,5 2 x 25 2 x 32 115-135 DN 100 DN 100
SDC2 XVM 32-9 3 400 2 x 18,5 2 x 25 2 x 32 120-140 DN 100 DN 100
SDC2 XVM 32-10-2 3 400 2 x 18,5 2 x 25 2 x 32 130-150 DN 100 DN 100
SDC2 XVM 32-10 3 400 2 x 18,5 2 x 25 2 x 32 135-155 DN 100 DN 100
SDC2 XVM 32-11-2 3 400 2 x 22 2 x 30 2 x 32 145-165 DN 100 DN 100
SDC2 XVM 32-11 3 400 2 x 22 2 x 30 2 x 32 150-170 DN 100 DN 100
SDC2 XVM 32-12-2 3 400 2 x 22 2 x 30 2 x 32 155-175 DN 100 DN 100
SDC2 XVM 32-12 3 400 2 x 22 2 x 30 2 x 32 165-185 DN 100 DN 100
SDC2 XVM 32-13-2 3 400 2 x 30 2 x 40 2 x 32 170-190 DN 100 DN 100
SDC2 XVM 32-13 3 400 2 x 30 2 x 40 2 x 32 180-200 DN 100 DN 100
SDC2 XVM 32-14-2 3 400 2 x 30 2 x 40 2 x 32 190-210 DN 100 DN 100

SDC2 XVM 45-3-2 3 400 2 x 11 2 x 15 2 x 45 45-60 DN 125 DN 125


SDC2 XVM 45-3 3 400 2 x 11 2 x 15 2 x 45 55-70 DN 125 DN 125
SDC2 XVM 45-4-2 3 400 2 x 15 2 x 20 2 x 45 65-85 DN 125 DN 125
SDC2 XVM 45-4 3 400 2 x 15 2 x 20 2 x 45 75-95 DN 125 DN 125
SDC2 XVM 45-5-2 3 400 2 x 18,5 2 x 25 2 x 45 85-105 DN 125 DN 125
SDC2 XVM 45-5 3 400 2 x 18,5 2 x 25 2 x 45 95-115 DN 125 DN 125
SDC2 XVM 45-6-2 3 400 2 x 22 2 x 30 2 x 45 110-130 DN 125 DN 125
SDC2 XVM 45-6 3 400 2 x 22 2 x 30 2 x 45 120-140 DN 125 DN 125
SDC2 XVM 45-7-2 3 400 2 x 30 2 x 40 2 x 45 130-150 DN 125 DN 125
SDC2 XVM 45-7 3 400 2 x 30 2 x 40 2 x 45 140-160 DN 125 DN 125
SDC2 XVM 45-8-2 3 400 2 x 30 2 x 40 2 x 45 150-170 DN 125 DN 125
SDC2 XVM 45-8 3 400 2 x 30 2 x 40 2 x 45 155-175 DN 125 DN 125
SDC2 XVM 45-9-2 3 400 2 x 30 2 x 40 2 x 45 170-190 DN 125 DN 125
SDC2 XVM 45-9 3 400 2 x 37 2 x 50 2 x 45 180-200 DN 125 DN 125
SDC2 XVM 45-10-2 3 400 2 x 37 2 x 50 2 x 45 190-210 DN 125 DN 125

876
SDC2
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC2 XVM 64-2-1 3 400 2 x 11 2 x 15 2 x 64 30-45 DN 150 DN 150
SDC2 XVM 64-2 3 400 2 x 11 2 x 15 2 x 64 35-55 DN 150 DN 150
SDC2 XVM 64-3-2 3 400 2 x 15 2 x 20 2 x 64 45-65 DN 150 DN 150
SDC2 XVM 64-3-1 3 400 2 x 15 2 x 20 2 x 64 50-70 DN 150 DN 150
SDC2 XVM 64-3 3 400 2 x 18,5 2 x 25 2 x 64 60-80 DN 150 DN 150
SDC2 XVM 64-4-2 3 400 2 x 18,5 2 x 25 2 x 64 65-85 DN 150 DN 150
SDC2 XVM 64-4-1 3 400 2 x 22 2 x 30 2 x 64 75-95 DN 150 DN 150
SDC2 XVM 64-5-2 3 400 2 x 30 2 x 40 2 x 64 90-110 DN 150 DN 150
SDC2 XVM 64-5-1 3 400 2 x 30 2 x 40 2 x 64 95-115 DN 150 DN 150
SDC2 XVM 64-5 3 400 2 x 30 2 x 40 2 x 64 105-125 DN 150 DN 150
SDC2 XVM 64-6-2 3 400 2 x 30 2 x 40 2 x 64 115-135 DN 150 DN 150
SDC2 XVM 64-6-1 3 400 2 x 37 2 x 50 2 x 64 120-140 DN 150 DN 150
SDC2 XVM 64-6 3 400 2 x 37 2 x 50 2 x 64 125-145 DN 150 DN 150
SDC2 XVM 64-7-2 3 400 2 x 37 2 x 50 2 x 64 135-155 DN 150 DN 150
SDC2 XVM 64-7-1 3 400 2 x 37 2 x 50 2 x 64 140-160 DN 150 DN 150
SDC2 XVM 64-7 3 400 2 x 45 2 x 60 2 x 64 150-170 DN 150 DN 150
SDC2 XVM 64-8-2 3 400 2 x 45 2 x 60 2 x 64 155-175 DN 150 DN 150
SDC2 XVM 64-8-1 3 400 2 x 45 2 x 60 2 x 64 165-185 DN 150 DN 150

SDC2 XVM 90-2-2 3 400 2 x 11 2 x 15 2 x 90 25-40 DN 150 DN 150


SDC2 XVM 90-2 3 400 2 x 15 2 x 20 2 x 90 40-55 DN 150 DN 150
SDC2 XVM 90-3-2 3 400 2 x 18,5 2 x 25 2 x 90 50-65 DN 150 DN 150
SDC2 XVM 90-3 3 400 2 x 22 2 x 30 2 x 90 60-80 DN 150 DN 150
SDC2 XVM 90-4-2 3 400 2 x 30 2 x 40 2 x 90 70-90 DN 150 DN 150
SDC2 XVM 90-4 3 400 2 x 30 2 x 40 2 x 90 85-105 DN 150 DN 150
SDC2 XVM 90-5-2 3 400 2 x 37 2 x 50 2 x 90 95-115 DN 150 DN 150
SDC2 XVM 90-5 3 400 2 x 37 2 x 50 2 x 90 110-130 DN 150 DN 150
SDC2 XVM 90-6-2 3 400 2 x 45 2 x 60 2 x 90 120-140 DN 150 DN 150
SDC2 XVM 90-6 3 400 2 x 45 2 x 60 2 x 90 130-150 DN 150 DN 150

877
SDC2
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC2 WTX 50-200/9,2 3 400 2 x 9,2 2 x 12,5 2 x 50 40-47 DN 125 DN 125
SDC2 WTX 50-200/11 3 400 2 x 11 2 x 15 2 x 60 40-50 DN 125 DN 125
SDC2 WTX 50-200/15 3 400 2 x 15 2 x 20 2 x 60 54-62 DN 125 DN 125

SDC2 WTM 40-250/9,2 3 400 2 x 9,2 2 x 12,5 2 x 40 45-58 DN 100 DN 100


SDC2 WTM 40-250/11 3 400 2 x 11 2 x 15 2 x 40 50-65 DN 100 DN 100
SDC2 WTM 40-250/15 3 400 2 x 15 2 x 20 2 x 40 60-80 DN 100 DN 100

SDC2 WTM 50-200/9,2 3 400 2 x 9,2 2 x 12,5 2 x 75 30-45 DN 125 DN 125


SDC2 WTM 50-200/11 3 400 2 x 11 2 x 15 2 x 75 35-50 DN 125 DN 125
SDC2 WTM 50-250/15 3 400 2 x 15 2 x 20 2 x 75 45-60 DN 125 DN 125
SDC2 WTM 50-250/18,5 3 400 2 x 18,5 2 x 25 2 x 75 55-70 DN 125 DN 125
SDC2 WTM 50-250/22 3 400 2 x 22 2 x 30 2 x 85 60-80 DN 125 DN 125

SDC2 WTM 65-250/22 3 400 2 x 22 2 x 30 2 x 120 40-55 DN 200 DN 200


SDC2 WTM 65-250/30 3 400 2 x 30 2 x 40 2 x 120 60-70 DN 200 DN 200
SDC2 WTM 65-250/37 3 400 2 x 37 2 x 50 2 x 120 70-85 DN 200 DN 200

SDC2 WTM 80-160/15 3 400 2 x 15 2 x 20 2 x 190 20-30 DN 300 DN 250


SDC2 WTM 80-160/18,5 3 400 2 x 18,5 2 x 25 2 x 200 25-35 DN 300 DN 250
SDC2 WTM 80-200/22 3 400 2 x 22 2 x 30 2 x 190 30-42 DN 300 DN 250
SDC2 WTM 80-200/30 3 400 2 x 30 2 x 40 2 x 200 42-55 DN 300 DN 250
SDC2 WTM 80-250/37 3 400 2 x 37 2 x 50 2 x 190 45-65 DN 300 DN 250
SDC2 WTM 80-250/45 3 400 2 x 45 2 x 60 2 x 190 55-75 DN 300 DN 250
SDC2 WTM 80-250/55 3 400 2 x 55 2 x 75 2 x 190 70-85 DN 300 DN 250

878
SDC3
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC3 XVM 15-10 3 400 3 x 11 3 x 15 3 x 18 105-125 DN 100 3”
SDC3 XVM 15-12 3 400 3 x 11 3 x 15 3 x 18 125-145 DN 100 3”
SDC3 XVM 15-14 3 400 3 x 11 3 x 15 3 x 18 145-165 DN 100 3”
SDC3 XVM 15-16 3 400 3 x 15 3 x 20 3 x 18 170-190 DN 100 3”
SDC3 XVM 15-17 3 400 3 x 15 3 x 20 3 x 18 180-200 DN 100 3”

SDC3 XVM 20-8 3 400 3 x 11 3 x 15 3 x 20 70-90 DN 100 DN 100


SDC3 XVM 20-10 3 400 3 x 11 3 x 15 3 x 20 85-105 DN 100 DN 100
SDC3 XVM 20-12 3 400 3 x 15 3 x 20 3 x 20 110-130 DN 100 DN 100
SDC3 XVM 20-14 3 400 3 x 15 3 x 20 3 x 20 135-155 DN 100 DN 100
SDC3 XVM 20-16 3 400 3 x 18,5 3 x 25 3 x 20 160-180 DN 100 DN 100
SDC3 XVM 20-17 3 400 3 x 18,5 3 x 25 3 x 20 185-205 DN 100 DN 100

879
SDC3
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC3 XVM 32-5-2
SDC3 XVM 32-5 3 400 3 x 11 3 x 15 3 x 32 60-80 DN 125 DN 125
SDC3 XVM 32-6-2 3 400 3 x 11 3 x 15 3 x 32 70-90 DN 125 DN 125
SDC3 XVM 32-6 3 400 3 x 11 3 x 15 3 x 32 75-95 DN 125 DN 125
SDC3 XVM 32-7-2 3 400 3 x 15 3 x 20 3 x 32 85-105 DN 125 DN 125
SDC3 XVM 32-7 3 400 3 x 15 3 x 20 3 x 32 90-110 DN 125 DN 125
SDC3 XVM 32-8-2 3 400 3 x 15 3 x 20 3 x 32 100-120 DN 125 DN 125
SDC3 XVM 32-8 3 400 3 x 15 3 x 20 3 x 32 105-125 DN 125 DN 125
SDC3 XVM 32-9-2 3 400 3 x 18,5 3 x 25 3 x 32 115-135 DN 125 DN 125
SDC3 XVM 32-9 3 400 3 x 18,5 3 x 25 3 x 32 120-140 DN 125 DN 125
SDC3 XVM 32-10-2 3 400 3 x 18,5 3 x 25 3 x 32 130-150 DN 125 DN 125
SDC3 XVM 32-10 3 400 3 x 18,5 3 x 25 3 x 32 135-155 DN 125 DN 125
SDC3 XVM 32-11-2 3 400 3 x 22 3 x 30 3 x 32 145-165 DN 125 DN 125
SDC3 XVM 32-11 3 400 3 x 22 3 x 30 3 x 32 150-170 DN 125 DN 125
SDC3 XVM 32-12-2 3 400 3 x 22 3 x 30 3 x 32 155-175 DN 125 DN 125
SDC3 XVM 32-12 3 400 3 x 22 3 x 30 3 x 32 165-185 DN 125 DN 125
SDC3 XVM 32-13-2 3 400 3 x 30 3 x 40 3 x 32 170-190 DN 125 DN 125
SDC3 XVM 32-13 3 400 3 x 30 3 x 40 3 x 32 180-200 DN 125 DN 125
SDC3 XVM 32-14-2 3 400 3 x 30 3 x 40 3 x 32 190-210 DN 125 DN 125

SDC3 XVM 45-3-2 3 400 3 x 11 3 x 15 3 x 45 45-60 DN 150 DN 150


SDC3 XVM 45-3 3 400 3 x 11 3 x 15 3 x 45 55-70 DN 150 DN 150
SDC3 XVM 45-4-2 3 400 3 x 15 3 x 20 3 x 45 65-85 DN 150 DN 150
SDC3 XVM 45-4 3 400 3 x 15 3 x 20 3 x 45 75-95 DN 150 DN 150
SDC3 XVM 45-5-2 3 400 3 x 18,5 3 x 25 3 x 45 85-105 DN 150 DN 150
SDC3 XVM 45-5 3 400 3 x 18,5 3 x 25 3 x 45 95-115 DN 150 DN 150
SDC3 XVM 45-6-2 3 400 3 x 22 3 x 30 3 x 45 110-130 DN 150 DN 150
SDC3 XVM 45-6 3 400 3 x 22 3 x 30 3 x 45 120-140 DN 150 DN 150
SDC3 XVM 45-7-2 3 400 3 x 30 3 x 40 3 x 45 130-150 DN 150 DN 150
SDC3 XVM 45-7 3 400 3 x 30 3 x 40 3 x 45 140-160 DN 150 DN 150
SDC3 XVM 45-8-2 3 400 3 x 30 3 x 40 3 x 45 150-170 DN 150 DN 150
SDC3 XVM 45-8 3 400 3 x 30 3 x 40 3 x 45 155-175 DN 150 DN 150
SDC3 XVM 45-9-2 3 400 3 x 30 3 x 40 3 x 45 170-190 DN 150 DN 150
SDC3 XVM 45-9 3 400 3 x 37 3 x 50 3 x 45 180-200 DN 150 DN 150
SDC3 XVM 45-10-2 3 400 3 x 37 3 x 50 3 x 45 190-210 DN 150 DN 150

880
SDC3
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC3 XVM 64-2-1 3 400 3 x 11 3 x 15 3 x 64 30-45 DN 200 DN 200
SDC3 XVM 64-2 3 400 3 x 11 3 x 15 3 x 64 35-55 DN 200 DN 200
SDC3 XVM 64-3-2 3 400 3 x 15 3 x 20 3 x 64 45-65 DN 200 DN 200
SDC3 XVM 64-3-1 3 400 3 x 15 3 x 20 3 x 64 50-70 DN 200 DN 200
SDC3 XVM 64-3 3 400 3 x 18,5 3 x 25 3 x 64 60-80 DN 200 DN 200
SDC3 XVM 64-4-2 3 400 3 x 18,5 3 x 25 3 x 64 65-85 DN 200 DN 200
SDC3 XVM 64-4-1 3 400 3 x 22 3 x 30 3 x 64 75-95 DN 200 DN 200
SDC3 XVM 64-4 3 400 3 x 22 3 x 30 3 x 64 80-100 DN 200 DN 200
SDC3 XVM 64-5-2 3 400 3 x 30 3 x 40 3 x 64 90-110 DN 200 DN 200
SDC3 XVM 64-5-1 3 400 3 x 30 3 x 40 3 x 64 95-115 DN 200 DN 200
SDC3 XVM 64-5 3 400 3 x 30 3 x 40 3 x 64 105-125 DN 200 DN 200
SDC3 XVM 64-6-2 3 400 3 x 30 3 x 40 3 x 64 115-135 DN 200 DN 200
SDC3 XVM 64-6-1 3 400 3 x 37 3 x 50 3 x 64 120-140 DN 200 DN 200
SDC3 XVM 64-6 3 400 3 x 37 3 x 50 3 x 64 125-145 DN 200 DN 200
SDC3 XVM 64-7-2 3 400 3 x 37 3 x 50 3 x 64 135-155 DN 200 DN 200
SDC3 XVM 64-7-1 3 400 3 x 37 3 x 50 3 x 64 140-160 DN 200 DN 200
SDC3 XVM 64-7 3 400 3 x 45 3 x 60 3 x 64 150-170 DN 200 DN 200
SDC3 XVM 64-8-2 3 400 3 x 45 3 x 60 3 x 64 155-175 DN 200 DN 200
SDC3 XVM 64-8-1 3 400 3 x 45 3 x 60 3 x 64 165-185 DN 200 DN 200

SDC3 XVM 90-2-2 3 400 3 x 11 2 x 15 3 x 90 25-40 DN 200 DN 200


SDC3 XVM 90-2 3 400 3 x 15 3 x 20 3 x 90 40-55 DN 200 DN 200
SDC3 XVM 90-3-2 3 400 3 x 18,5 3 x 25 3 x 90 50-65 DN 200 DN 200
SDC3 XVM 90-3 3 400 3 x 22 3 x 30 3 x 90 60-80 DN 200 DN 200
SDC3 XVM 90-4-2 3 400 3 x 30 3 x 40 3 x 90 70-90 DN 200 DN 200
SDC3 XVM 90-4 3 400 3 x 30 3 x 40 3 x 90 85-105 DN 200 DN 200
SDC3 XVM 90-5-2 3 400 3 x 37 3 x 50 3 x 90 95-115 DN 200 DN 200
SDC3 XVM 90-5 3 400 3 x 37 3 x 50 3 x 90 110-130 DN 200 DN 200
SDC3 XVM 90-6-2 3 400 3 x 45 3 x 60 3 x 90 120-140 DN 200 DN 200
SDC3 XVM 90-6 3 400 3 x 45 3 x 60 3 x 90 130-150 DN 200 DN 200

881
SDC3
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC3 WTX 50-200/11 3 400 3 x 11 3 x 15 3 x 60 40-50 DN 200 DN 200
SDC3 WTX 50-200/15 3 400 3 x 15 3 x 20 3 x 60 54-62 DN 200 DN 200

SDC3 WTM 40-250/9,2 3 400 3 x 9,2 3 x 12,5 3 x 40 45-58 DN 150 DN 150


SDC3 WTM 40-250/11 3 400 3 x 11 3 x 15 3 x 40 50-65 DN 150 DN 150
SDC3 WTM 40-250/15 3 400 3 x 15 3 x 20 3 x 40 60-80 DN 150 DN 150

SDC3 WTM 50-200/9,2 3 400 3 x 9,2 3 x 12,5 3 x 75 30-45 DN 200 DN 200


SDC3 WTM 50-200/11 3 400 3 x 11 3 x 15 3 x 75 35-50 DN 200 DN 200
SDC3 WTM 50-250/15 3 400 3 x 15 3 x 20 3 x 75 45-60 DN 200 DN 200
SDC3 WTM 50-250/18,5 3 400 3 x 18,5 3 x 25 3 x 75 55-70 DN 200 DN 200
SDC3 WTM 50-250/22 3 400 3 x 22 3 x 30 3 x 85 60-80 DN 200 DN 200

SDC3 WTM 65-250/22 3 400 3 x 22 3 x 30 3 x 120 40-55 DN 250 DN 200


SDC3 WTM 65-250/30 3 400 3 x 30 3 x 40 3 x 120 60-70 DN 250 DN 200
SDC3 WTM 65-250/37 3 400 3 x 37 3 x 50 3 x 120 70-85 DN 250 DN 200

SDC3 WTM 80-160/15 3 400 3 x 15 3 x 20 3 x 190 20-30 DN 350 DN 300


SDC3 WTM 80-160/18,5 3 400 3 x 18,5 3 x 25 3 x 200 25-35 DN 350 DN 300
SDC3 WTM 80-200/22 3 400 3 x 22 3 x 30 3 x 190 30-42 DN 350 DN 300
SDC3 WTM 80-200/30 3 400 3 x 30 3 x 40 3 x 200 42-55 DN 350 DN 300
SDC3 WTM 80-250/37 3 400 3 x 37 3 x 50 3 x 190 45-65 DN 350 DN 300
SDC3 WTM 80-250/45 3 400 3 x 45 3 x 60 3 x 190 55-75 DN 350 DN 300
SDC3 WTM 80-250/55 3 400 3 x 55 3 x 75 3 x 190 70-85 DN 350 DN 300

882
SDC4
Industrial Boosters

Performance Table

Voltage Flow Operating


Model Phase Motor Power Diameter of Manifold
(V) (m3/h) Pressure (mWC)
Voltage Motor Power Flow Operating Diameter of Manifold
Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC4 XVM 1-9 3 400 4 x 0,55 4 x 0,75 4 x 1,8 37-49 2" 2"
SDC4 XVM 1-10 3 400 4 x 0,55 4 x 0,75 4 x 1,8 40-55 2” 2”
SDC4 XVM 1-11 3 400 4 x 0,55 4 x 0,75 4 x 1,8 45-60 2” 2”
SDC4 XVM 1-12 3 400 4 x 0,75 4x1 4 x 1,8 50-65 2” 2”
SDC4 XVM 1-13 3 400 4 x 0,75 4x1 4 x 1,8 55-70 2” 2”

883
SDC4
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC4 XVM 1-15 3 400 4 x 0,75 4x1 4 x 1,8 65-85 2" 2"
SDC4 XVM 1-17 3 400 4 x 1,1 4 x 1,5 4 x 1,8 75-95 2” 2”
SDC4 XVM 1-19 3 400 4 x 1,1 4 x 1,5 4 x 1,8 85-105 2” 2”
SDC4 XVM 1-21 3 400 4 x 1,1 4 x 1,5 4 x 1,8 95-115 2” 2”
SDC4 XVM 1-23 3 400 4 x 1,1 4 x 1,5 4 x 1,8 105-125 2” 2”
SDC4 XVM 1-25 3 400 4 x 1,5 4x2 4 x 1,8 115-135 2” 2”
SDC4 XVM 1-27 3 400 4 x 1,5 4x2 4 x 1,8 120-140 2” 2”
SDC4 XVM 1-30 3 400 4 x 1,5 4x2 4 x 1,8 135-155 2” 2”
SDC4 XVM 1-33 3 400 4 x 2,2 4x3 4 x 1,8 150-170 2” 2”
SDC4 XVM 1-36 3 400 4 x 2,2 4x3 4 x 1,8 165-185 2” 2”

SDC4 XVM 3-6 3 400 4 x 0,55 4 x 0,75 4x3 22-34 2” 2”


SDC4 XVM 3-7 3 400 4 x 0,55 4 x 0,75 4x3 25-38 2” 2”
SDC4 XVM 3-8 3 400 4 x 0,75 4x1 4x3 30-45 2” 2”
SDC4 XVM 3-9 3 400 4 x 0,75 4x1 4x3 35-50 2” 2”
SDC4 XVM 3-10 3 400 4 x 0,75 4x1 4x3 40-55 2” 2”
SDC4 XVM 3-11 3 400 4 x 1,1 4 x 1,5 4x3 45-60 2” 2”
SDC4 XVM 3-12 3 400 4 x 1,1 4 x 1,5 4x3 50-65 2” 2”
SDC4 XVM 3-13 3 400 4 x 1,1 4 x 1,5 4x3 55-70 2” 2”
SDC4 XVM 3-15 3 400 4 x 1,1 4 x 1,5 4x3 65-85 2” 2”
SDC4 XVM 3-17 3 400 4 x 1,5 4x2 4x3 75-95 2” 2”
SDC4 XVM 3-19 3 400 4 x 1,5 4x2 4x3 85-105 2” 2”
SDC4 XVM 3-21 3 400 4 x 2,2 4x3 4x3 95-115 2” 2”
SDC4 XVM 3-23 3 400 4 x 2,2 4x3 4x3 105-125 2” 2”
SDC4 XVM 3-25 3 400 4 x 2,2 4x3 4x3 110-130 2” 2”
SDC4 XVM 3-27 3 400 4 x 2,2 4x3 4x3 120-140 2” 2”
SDC4 XVM 3-29 3 400 4 x 2,2 4x3 4x3 130-150 2” 2”
SDC4 XVM 3-31 3 400 4x3 4x4 4x3 140-160 2” 2”
SDC4 XVM 3-33 3 400 4x3 4x4 4x3 150-170 2” 2”
SDC4 XVM 3-36 3 400 4x3 4x4 4x3 165-185 2” 2”

884
SDC4
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC4 XVM 5-8 3 400 4 x 1,1 4 x 1,5 4 x 5,5 30-45 2½” 2½”
SDC4 XVM 5-9 3 400 4 x 1,5 4x2 4 x 5,5 35-50 2½” 2½”
SDC4 XVM 5-10 3 400 4 x 1,5 4x2 4 x 5,5 40-58 2½” 2½”
SDC4 XVM 5-11 3 400 4 x 2,2 4x3 4 x 5,5 45-65 2½” 2½”
SDC4 XVM 5-12 3 400 4 x 2,2 4x3 4 x 5,5 50-70 2½” 2½”
SDC4 XVM 5-13 3 400 4 x 2,2 4x3 4 x 5,5 55-75 2½” 2½”
SDC4 XVM 5-14 3 400 4 x 2,2 4x3 4 x 5,5 65-85 2½” 2½”
SDC4 XVM 5-15 3 400 4 x 2,2 4x3 4 x 5,5 75-95 2½” 2½”
SDC4 XVM 5-16 3 400 4 x 2,2 4x3 4 x 5,5 80-100 2½” 2½”
SDC4 XVM 5-18 3 400 4x3 4x4 4 x 5,5 90-110 2½” 2½”
SDC4 XVM 5-20 3 400 4x3 4x4 4 x 5,5 95-115 2½” 2½”
SDC4 XVM 5-22 3 400 4x4 4 x 5,5 4 x 5,5 110-130 2½” 2½”
SDC4 XVM 5-24 3 400 4x4 4 x 5,5 4 x 5,5 120-140 2½” 2½”
SDC4 XVM 5-26 3 400 4x4 4 x 5,5 4 x 5,5 130-150 2½” 2½”
SDC4 XVM 5-29 3 400 4x4 4 x 5,5 4 x 5,5 150-170 2½” 2½”
SDC4 XVM 5-32 3 400 4 x 5,5 4 x 7,5 4 x 5,5 165-185 2½” 2½”
SDC4 XVM 5-36 3 400 4 x 5,5 4 x 7,5 4 x 5,5 185-205 2½” 2½”

SDC4 XVM 10-4 3 400 4 x 1,5 4x2 4 x 10 28-40 3” 3”


SDC4 XVM 10-5 3 400 4 x 2,2 4x3 4 x 10 35-50 3” 3”
SDC4 XVM 10-6 3 400 4 x 2,2 4x3 4 x 10 40-58 3” 3”
SDC4 XVM 10-7 3 400 4x3 4x4 4 x 10 50-70 3” 3”
SDC4 XVM 10-8 3 400 4x3 4x4 4 x 10 60-80 3” 3”
SDC4 XVM 10-9 3 400 4x3 4x4 4 x 10 70-90 3” 3”
SDC4 XVM 10-10 3 400 4x4 4 x 5,5 4 x 10 80-100 3” 3”
SDC4 XVM 10-12 3 400 4x4 4 x 5,5 4 x 10 95-115 3” 3”
SDC4 XVM 10-14 3 400 4 x 5,5 4 x 7,5 4 x 10 110-130 3” 3”
SDC4 XVM 10-16 3 400 4 x 5,5 4 x 7,5 4 x 10 125-145 3” 3”
SDC4 XVM 10-18 3 400 4 x 7,5 4 x 10 4 x 10 140-160 3” 3”
SDC4 XVM 10-20 3 400 4 x 7,5 4 x 10 4 x 10 160-180 3” 3”
SDC4 XVM 10-22 3 400 4 x 7,5 4 x 10 4 x 10 180-200 3” 3”

885
SDC4
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC4 XVM 15-4 3 400 4x4 4 x 5,5 4 x 18 35-50 DN 100 DN 100
SDC4 XVM 15-5 3 400 4x4 4 x 5,5 4 x 18 45-60 DN 100 DN 100
SDC4 XVM 15-6 3 400 4 x 5,5 4 x 7,5 4 x 18 55-75 DN 100 DN 100
SDC4 XVM 15-7 3 400 4 x 5,5 4 x 7,5 4 x 18 70-90 DN 100 DN 100
SDC4 XVM 15-8 3 400 4 x 7,5 4 x 10 4 x 18 80-100 DN 100 DN 100
SDC4 XVM 15-9 3 400 4 x 7,5 4 x 10 4 x 18 95-115 DN 100 DN 100
SDC4 XVM 15-10 3 400 4 x 11 4 x 15 4 x 18 105-125 DN 100 DN 100
SDC4 XVM 15-12 3 400 4 x 11 4 x 15 4 x 18 125-145 DN 100 DN 100
SDC4 XVM 15-14 3 400 4 x 11 4 x 15 4 x 18 145-165 DN 100 DN 100
SDC4 XVM 15-16 3 400 4 x 15 4 x 20 4 x 18 170-190 DN 100 DN 100
SDC4 XVM 15-17 3 400 4 x 15 4 x 20 4 x 18 180-200 DN 100 DN 100

SDC4 XVM 20-4 3 400 4 x 5,5 4 x 7,5 4 x 20 25-37 DN 125 DN 100


SDC4 XVM 20-5 3 400 4 x 5,5 4 x 7,5 4 x 20 38-50 DN 125 DN 100
SDC4 XVM 20-6 3 400 4 x 7,5 4 x 10 4 x 20 45-65 DN 125 DN 100
SDC4 XVM 20-7 3 400 4 x 7,5 4 x 10 4 x 20 60-80 DN 125 DN 100
SDC4 XVM 20-8 3 400 4 x 11 4 x 15 4 x 20 70-90 DN 125 DN 100
SDC4 XVM 20-10 3 400 4 x 11 4 x 15 4 x 20 85-105 DN 125 DN 100
SDC4 XVM 20-12 3 400 4 x 15 4 x 20 4 x 20 110-130 DN 125 DN 100
SDC4 XVM 20-14 3 400 4 x 15 4 x 20 4 x 20 135-155 DN 125 DN 100
SDC4 XVM 20-16 3 400 4 x 18,5 4 x 25 4 x 20 160-180 DN 125 DN 100
SDC4 XVM 20-17 3 400 4 x 18,5 4 x 25 4 x 20 185-205 DN 125 DN 100

SDC4 XVM 32-3-2 3 400 4x4 4 x 5,5 4 x 32 30-45 DN 150 DN 150


SDC4 XVM 32-3 3 400 4 x 5,5 4 x 7,5 4 x 32 35-50 DN 150 DN 150
SDC4 XVM 32-4-2 3 400 4 x 7,5 4 x 10 4 x 32 40-60 DN 150 DN 150
SDC4 XVM 32-4 3 400 4 x 7,5 4 x 10 4 x 32 45-65 DN 150 DN 150
SDC4 XVM 32-5-2 3 400 4 x 11 4 x 15 4 x 32 55-75 DN 150 DN 150
SDC4 XVM 32-5 3 400 4 x 11 4 x 15 4 x 32 60-80 DN 150 DN 150
SDC4 XVM 32-6-2 3 400 4 x 11 4 x 15 4 x 32 70-90 DN 150 DN 150
SDC4 XVM 32-6 3 400 4 x 11 4 x 15 4 x 32 75-95 DN 150 DN 150
SDC4 XVM 32-7-2 3 400 4 x 15 4 x 20 4 x 32 85-105 DN 150 DN 150
SDC4 XVM 32-7 3 400 4 x 15 4 x 20 4 x 32 90-110 DN 150 DN 150
SDC4 XVM 32-8-2 3 400 4 x 15 4 x 20 4 x 32 100-120 DN 150 DN 150
SDC4 XVM 32-8 3 400 4 x 15 4 x 20 4 x 32 105-125 DN 150 DN 150

886
SDC4
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC4 XVM 32-9-2 3 400 4 x 18,5 4 x 25 4 x 32 115-135 DN 150 DN 150
SDC4 XVM 32-9 3 400 4 x 18,5 4 x 25 4 x 32 120-140 DN 150 DN 150
SDC4 XVM 32-10-2 3 400 4 x 18,5 4 x 25 4 x 32 130-150 DN 150 DN 150
SDC4 XVM 32-10 3 400 4 x 18,5 4 x 25 4 x 32 135-155 DN 150 DN 150
SDC4 XVM 32-11-2 3 400 4 x 22 4 x 30 4 x 32 145-165 DN 150 DN 150
SDC4 XVM 32-11 3 400 4 x 22 4 x 30 4 x 32 150-170 DN 150 DN 150
SDC4 XVM 32-12-2 3 400 4 x 22 4 x 30 4 x 32 155-175 DN 150 DN 150
SDC4 XVM 32-12 3 400 4 x 22 4 x 30 4 x 32 165-185 DN 150 DN 150
SDC4 XVM 32-13-2 3 400 4 x 30 4 x 40 4 x 32 170-190 DN 150 DN 150
SDC4 XVM 32-13 3 400 4 x 30 4 x 40 4 x 32 180-200 DN 150 DN 150
SDC4 XVM 32-14-2 3 400 4 x 30 4 x 40 4 x 32 190-210 DN 150 DN 150

SDC4 XVM 45-3-2 3 400 4 x 11 4 x 15 4 x 45 45-60 DN 200 DN 150


SDC4 XVM 45-3 3 400 4 x 11 4 x 15 4 x 45 55-70 DN 200 DN 150
SDC4 XVM 45-4-2 3 400 4 x 15 4 x 20 4 x 45 65-85 DN 200 DN 150
SDC4 XVM 45-4 3 400 4 x 15 4 x 20 4 x 45 75-95 DN 200 DN 150
SDC4 XVM 45-5-2 3 400 4 x 18,5 4 x 25 4 x 45 85-105 DN 200 DN 150
SDC4 XVM 45-5 3 400 4 x 18,5 4 x 25 4 x 45 95-115 DN 200 DN 150
SDC4 XVM 45-6-2 3 400 4 x 22 4 x 30 4 x 45 110-130 DN 200 DN 150
SDC4 XVM 45-6 3 400 4 x 22 4 x 30 4 x 45 120-140 DN 200 DN 150
SDC4 XVM 45-7-2 3 400 4 x 30 4 x 40 4 x 45 130-150 DN 200 DN 150
SDC4 XVM 45-7 3 400 4 x 30 4 x 40 4 x 45 140-160 DN 200 DN 150
SDC4 XVM 45-8-2 3 400 4 x 30 4 x 40 4 x 45 150-170 DN 200 DN 150
SDC4 XVM 45-8 3 400 4 x 30 4 x 40 4 x 45 155-175 DN 200 DN 150
SDC4 XVM 45-9-2 3 400 4 x 30 4 x 40 4 x 45 170-190 DN 200 DN 150
SDC4 XVM 45-9 3 400 4 x 37 4 x 50 4 x 45 180-200 DN 200 DN 150
SDC4 XVM 45-10-2 3 400 4 x 37 4 x 50 4 x 45 190-210 DN 200 DN 150

SDC4 XVM 64-2-1 3 400 4 x 11 4 x 15 4 x 64 30-45 DN 250 DN 200


SDC4 XVM 64-2 3 400 4 x 11 4 x 15 4 x 64 35-55 DN 250 DN 200
SDC4 XVM 64-3-2 3 400 4 x 15 4 x 20 4 x 64 45-65 DN 250 DN 200
SDC4 XVM 64-3-1 3 400 4 x 15 4 x 20 4 x 64 50-70 DN 250 DN 200
SDC4 XVM 64-3 3 400 4 x 18,5 4 x 25 4 x 64 60-80 DN 250 DN 200

887
SDC4
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC4 XVM 64-4-2 3 400 4 x 18,5 4 x 25 4 x 64 65-85 DN 250 DN 200
SDC4 XVM 64-4-1 3 400 4 x 22 4 x 30 4 x 64 75-95 DN 250 DN 200
SDC4 XVM 64-4 3 400 4 x 22 4 x 30 4 x 64 80-100 DN 250 DN 200
SDC4 XVM 64-5-2 3 400 4 x 30 4 x 40 4 x 64 90-110 DN 250 DN 200
SDC4 XVM 64-5-1 3 400 4 x 30 4 x 40 4 x 64 95-115 DN 250 DN 200
SDC4 XVM 64-5 3 400 4 x 30 4 x 40 4 x 64 105-125 DN 250 DN 200
SDC4 XVM 64-6-2 3 400 4 x 30 4 x 40 4 x 64 115-135 DN 250 DN 200
SDC4 XVM 64-6-1 3 400 4 x 37 4 x 50 4 x 64 120-140 DN 250 DN 200
SDC4 XVM 64-6 3 400 4 x 37 4 x 50 4 x 64 125-145 DN 250 DN 200
SDC4 XVM 64-7-2 3 400 4 x 37 4 x 50 4 x 64 135-155 DN 250 DN 200
SDC4 XVM 64-7-1 3 400 4 x 37 4 x 50 4 x 64 140-160 DN 250 DN 200
SDC4 XVM 64-7 3 400 4 x 45 4 x 60 4 x 64 150-170 DN 250 DN 200
SDC4 XVM 64-8-2 3 400 4 x 45 4 x 60 4 x 64 155-175 DN 250 DN 200
SDC4 XVM 64-8-1 3 400 4 x 45 4 x 60 4 x 64 165-185 DN 250 DN 200

SDC4 XVM 90-2-2 3 400 4 x 11 4 x 15 4 x 90 25-40 DN 250 DN 250


SDC4 XVM 90-2 3 400 4 x 15 4 x 20 4 x 90 40-55 DN 250 DN 250
SDC4 XVM 90-3-2 3 400 4 x 18,5 4 x 25 4 x 90 50-65 DN 250 DN 250
SDC4 XVM 90-3 3 400 4 x 22 4 x 30 4 x 90 60-80 DN 250 DN 250
SDC4 XVM 90-4-2 3 400 4 x 30 4 x 40 4 x 90 70-90 DN 250 DN 250
SDC4 XVM 90-4 3 400 4 x 30 4 x 40 4 x 90 85-105 DN 250 DN 250
SDC4 XVM 90-5-2 3 400 4 x 37 4 x 50 4 x 90 95-115 DN 250 DN 250
SDC4 XVM 90-5 3 400 4 x 37 4 x 50 4 x 90 110-130 DN 250 DN 250
SDC4 XVM 90-6-2 3 400 4 x 45 4 x 60 4 x 90 120-140 DN 250 DN 250
SDC4 XVM 90-6 3 400 4 x 45 4 x 60 4 x 90 130-150 DN 250 DN 250

888
SDC4
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC5 XVM 1-9 3 400 5 x 0,55 5 x 0,75 5 x 1,8 37-49 2" 2"
SDC5 XVM 1-10 3 400 5 x 0,55 5 x 0,75 5 x 1,8 40-55 2” 2”
SDC5 XVM 1-11 3 400 5 x 0,55 5 x 0,75 5 x 1,8 45-60 2” 2”
SDC5 XVM 1-12 3 400 5 x 0,75 5x1 5 x 1,8 50-65 2” 2”
SDC5 XVM 1-13 3 400 5 x 0,75 5x1 5 x 1,8 55-70 2” 2”
SDC5 XVM 1-15 3 400 5 x 0,75 5x1 5 x 1,8 65-85 2” 2”

889
SDC5
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC5 XVM 1-17 3 400 5 x 1,1 5 x 1,5 5 x 1,8 75-95 2" 2"
SDC5 XVM 1-19 3 400 5 x 1,1 5 x 1,5 5 x 1,8 85-105 2” 2”
SDC5 XVM 1-21 3 400 5 x 1,1 5 x 1,5 5 x 1,8 95-115 2” 2”
SDC5 XVM 1-23 3 400 5 x 1,1 5 x 1,5 5 x 1,8 105-125 2” 2”
SDC5 XVM 1-25 3 400 5 x 1,5 5x2 5 x 1,8 115-135 2” 2”
SDC5 XVM 1-27 3 400 5 x 1,5 5x2 5 x 1,8 120-140 2” 2”
SDC5 XVM 1-30 3 400 5 x 1,5 5x2 5 x 1,8 135-155 2” 2”
SDC5 XVM 1-33 3 400 5 x 2,2 5x3 5 x 1,8 150-170 2” 2”
SDC5 XVM 1-36 3 400 5 x 2,2 5x3 5 x 1,8 165-185 2” 2”

SDC5 XVM 3-6 3 400 5 x 0,55 5 x 0,75 5x3 22-34 2½” 2”


SDC5 XVM 3-7 3 400 5 x 0,55 5 x 0,75 5x3 25-38 2½” 2”
SDC5 XVM 3-8 3 400 5 x 0,75 5x1 5x3 30-45 2½” 2”
SDC5 XVM 3-9 3 400 5 x 0,75 5x1 5x3 35-50 2½” 2”
SDC5 XVM 3-10 3 400 5 x 0,75 5x1 5x3 40-55 2½” 2”
SDC5 XVM 3-11 3 400 5 x 1,1 5 x 1,5 5x3 45-60 2½” 2”
SDC5 XVM 3-12 3 400 5 x 1,1 5 x 1,5 5x3 50-65 2½” 2”
SDC5 XVM 3-13 3 400 5 x 1,1 5 x 1,5 5x3 55-70 2½” 2”
SDC5 XVM 3-15 3 400 5 x 1,1 5 x 1,5 5x3 65-85 2½” 2”
SDC5 XVM 3-17 3 400 5 x 1,5 5x2 5x3 75-95 2½” 2”
SDC5 XVM 3-19 3 400 5 x 1,5 5x2 5x3 85-105 2½” 2”
SDC5 XVM 3-21 3 400 5 x 2,2 5x3 5x3 95-115 2½” 2”
SDC5 XVM 3-23 3 400 5 x 2,2 5x3 5x3 105-125 2½” 2”
SDC5 XVM 3-25 3 400 5 x 2,2 5x3 5x3 110-130 2½” 2”
SDC5 XVM 3-27 3 400 5 x 2,2 5x3 5x3 120-140 2½” 2”
SDC5 XVM 3-29 3 400 5 x 2,2 5x3 5x3 130-150 2½” 2”
SDC5 XVM 3-31 3 400 5x3 5x4 5x3 140-160 2½” 2”
SDC5 XVM 3-33 3 400 5x3 5x4 5x3 150-170 2½” 2”
SDC5 XVM 3-36 3 400 5x3 5x4 5x3 165-185 2½” 2”

SDC5 XVM 5-8 3 400 5 x 1,1 5 x 1,5 5 x 5,5 30-45 3" 2 1/2"
SDC5 XVM 5-9 3 400 5 x 1,5 5x2 5 x 5,5 35-50 3” 2½”
SDC5 XVM 5-10 3 400 5 x 1,5 5x2 5 x 5,5 40-58 3” 2½”
SDC5 XVM 5-11 3 400 5 x 2,2 5x3 5 x 5,5 45-65 3” 2½”

890
SDC5
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC5 XVM 5-12 3 400 5 x 2,2 5x3 5 x 5,5 50-70 3” 2½”
SDC5 XVM 5-13 3 400 5 x 2,2 5x3 5 x 5,5 55-75 3” 2½”
SDC5 XVM 5-14 3 400 5 x 2,2 5x3 5 x 5,5 65-85 3” 2½”
SDC5 XVM 5-15 3 400 5 x 2,2 5x3 5 x 5,5 75-95 3” 2½”
SDC5 XVM 5-16 3 400 5 x 2,2 5x3 5 x 5,5 80-100 3” 2½”
SDC5 XVM 5-18 3 400 5x3 5x4 5 x 5,5 90-110 3” 2½”
SDC5 XVM 5-20 3 400 5x3 5x4 5 x 5,5 95-115 3” 2½”
SDC5 XVM 5-22 3 400 5x4 5 x 5,5 5 x 5,5 110-130 3” 2½”
SDC5 XVM 5-24 3 400 5x4 5 x 5,5 5 x 5,5 120-140 3” 2½”
SDC5 XVM 5-26 3 400 5x4 5 x 5,5 5 x 5,5 130-150 3” 2½”
SDC5 XVM 5-29 3 400 5x4 5 x 5,5 5 x 5,5 150-170 3” 2½”
SDC5 XVM 5-32 3 400 5 x 5,5 5 x 7,5 5 x 5,5 165-185 3” 2½”
SDC5 XVM 5-36 3 400 5 x 5,5 5 x 7,5 5 x 5,5 185-205 3” 2½”

SDC5 XVM 10-4 3 400 5 x 1,5 5x2 5 x 10 28-40 DN 100 DN 100


SDC5 XVM 10-5 3 400 5 x 2,2 5x3 5 x 10 35-50 DN 100 DN 100
SDC5 XVM 10-6 3 400 5 x 2,2 5x3 5 x 10 40-58 DN 100 DN 100
SDC5 XVM 10-7 3 400 5x3 5x4 5 x 10 50-70 DN 100 DN 100
SDC5 XVM 10-8 3 400 5x3 5x4 5 x 10 60-80 DN 100 DN 100
SDC5 XVM 10-9 3 400 5x3 5x4 5 x 10 70-90 DN 100 DN 100
SDC5 XVM 10-10 3 400 5x4 5 x 5,5 5 x 10 80-100 DN 100 DN 100
SDC5 XVM 10-12 3 400 5x4 5 x 5,5 5 x 10 95-115 DN 100 DN 100
SDC5 XVM 10-14 3 400 5 x 5,5 5 x 7,5 5 x 10 110-130 DN 100 DN 100
SDC5 XVM 10-16 3 400 5 x 5,5 5 x 7,5 5 x 10 125-145 DN 100 DN 100
SDC5 XVM 10-18 3 400 5 x 7,5 5 x 10 5 x 10 140-160 DN 100 DN 100
SDC5 XVM 10-20 3 400 5 x 7,5 5 x 10 5 x 10 160-180 DN 100 DN 100
SDC5 XVM 10-22 3 400 5 x 7,5 5 x 10 5 x 10 180-200 DN 100 DN 100

SDC5 XVM 15-4 3 400 5x4 5 x 5,5 5 x 18 35-50 DN 125 DN 125


SDC5 XVM 15-5 3 400 5x4 5 x 5,5 5 x 18 45-60 DN 125 DN 125
SDC5 XVM 15-6 3 400 5 x 5,5 5 x 7,5 5 x 18 55-75 DN 125 DN 125
SDC5 XVM 15-7 3 400 5 x 5,5 5 x 7,5 5 x 18 70-90 DN 125 DN 125
SDC5 XVM 15-8 3 400 5 x 7,5 5 x 10 5 x 18 80-100 DN 125 DN 125

891
SDC5
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC5 XVM 15-9 3 400 5 x 7,5 5 x 10 5 x 18 95-115 DN 125 DN 125
SDC5 XVM 15-10 3 400 5 x 11 5 x 15 5 x 18 105-125 DN 125 DN 125
SDC5 XVM 15-12 3 400 5 x 11 5 x 15 5 x 18 125-145 DN 125 DN 125
SDC5 XVM 15-14 3 400 5 x 11 5 x 15 5 x 18 145-165 DN 125 DN 125
SDC5 XVM 15-16 3 400 5 x 15 5 x 20 5 x 18 170-190 DN 125 DN 125
SDC5 XVM 15-17 3 400 5 x 15 5 x 20 5 x 18 180-200 DN 125 DN 125

SDC5 XVM 20-4 3 400 5 x 5,5 5 x 7,5 5 x 20 25-37 DN 125 DN 125


SDC5 XVM 20-5 3 400 5 x 5,5 5 x 7,5 5 x 20 38-50 DN 125 DN 125
SDC5 XVM 20-6 3 400 5 x 7,5 5 x 10 5 x 20 45-65 DN 125 DN 125
SDC5 XVM 20-7 3 400 5 x 7,5 5 x 10 5 x 20 60-80 DN 125 DN 125
SDC5 XVM 20-8 3 400 5 x 11 5 x 15 5 x 20 70-90 DN 125 DN 125
SDC5 XVM 20-10 3 400 5 x 11 5 x 15 5 x 20 85-105 DN 125 DN 125
SDC5 XVM 20-12 3 400 5 x 15 5 x 20 5 x 20 110-130 DN 125 DN 125
SDC5 XVM 20-14 3 400 5 x 15 5 x 20 5 x 20 135-155 DN 125 DN 125
SDC5 XVM 20-16 3 400 5 x 18,5 5 x 25 5 x 20 160-180 DN 125 DN 125
SDC5 XVM 20-17 3 400 5 x 18,5 5 x 25 5 x 20 185-205 DN 125 DN 125

SDC5 XVM 32-3-2 3 400 5x4 5 x 5,5 5 x 32 30-45 DN 200 DN 150


SDC5 XVM 32-3 3 400 5 x 5,5 5 x 7,5 5 x 32 35-50 DN 200 DN 150
SDC5 XVM 32-4-2 3 400 5 x 7,5 5 x 10 5 x 32 40-60 DN 200 DN 150
SDC5 XVM 32-4 3 400 5 x 7,5 5 x 10 5 x 32 45-65 DN 200 DN 150
SDC5 XVM 32-5-2 3 400 5 x 11 5 x 15 5 x 32 55-75 DN 200 DN 150
SDC5 XVM 32-5 3 400 5 x 11 5 x 15 5 x 32 60-80 DN 200 DN 150
SDC5 XVM 32-6-2 3 400 5 x 11 5 x 15 5 x 32 70-90 DN 200 DN 150
SDC5 XVM 32-6 3 400 5 x 11 5 x 15 5 x 32 75-95 DN 200 DN 150
SDC5 XVM 32-7-2 3 400 5 x 15 5 x 20 5 x 32 85-105 DN 200 DN 150
SDC5 XVM 32-7 3 400 5 x 15 5 x 20 5 x 32 90-110 DN 200 DN 150
SDC5 XVM 32-8-2 3 400 5 x 15 5 x 20 5 x 32 100-120 DN 200 DN 150
SDC5 XVM 32-8 3 400 5 x 15 5 x 20 5 x 32 105-125 DN 200 DN 150
SDC5 XVM 32-9-2 3 400 5 x 18,5 5 x 25 5 x 32 115-135 DN 200 DN 150
SDC5 XVM 32-9 3 400 5 x 18,5 5 x 25 5 x 32 120-140 DN 200 DN 150
SDC5 XVM 32-10-2 3 400 5 x 18,5 5 x 25 5 x 32 130-150 DN 200 DN 150
SDC5 XVM 32-10 3 400 5 x 18,5 5 x 25 5 x 32 135-155 DN 200 DN 150

892
SDC5
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC5 XVM 32-11-2 3 400 5 x 22 5 x 30 5 x 32 145-165 DN 200 DN 150
SDC5 XVM 32-11 3 400 5 x 22 5 x 30 5 x 32 150-170 DN 200 DN 150
SDC5 XVM 32-12-2 3 400 5 x 22 5 x 30 5 x 32 155-175 DN 200 DN 150
SDC5 XVM 32-12 3 400 5 x 22 5 x 30 5 x 32 165-185 DN 200 DN 150
SDC5 XVM 32-13-2 3 400 5 x 30 5 x 40 5 x 32 170-190 DN 200 DN 150
SDC5 XVM 32-13 3 400 5 x 30 5 x 40 5 x 32 180-200 DN 200 DN 150
SDC5 XVM 32-14-2 3 400 5 x 30 5 x 40 5 x 32 190-210 DN 200 DN 150

SDC5 XVM 45-3-2 3 400 5 x 11 5 x 15 5 x 45 45-60 DN 200 DN 200


SDC5 XVM 45-3 3 400 5 x 11 5 x 15 5 x 45 55-70 DN 200 DN 200
SDC5 XVM 45-4-2 3 400 5 x 15 5 x 20 5 x 45 65-85 DN 200 DN 200
SDC5 XVM 45-4 3 400 5 x 15 5 x 20 5 x 45 75-95 DN 200 DN 200
SDC5 XVM 45-5-2 3 400 5 x 18,5 5 x 25 5 x 45 85-105 DN 200 DN 200
SDC5 XVM 45-5 3 400 5 x 18,5 5 x 25 5 x 45 95-115 DN 200 DN 200
SDC5 XVM 45-6-2 3 400 5 x 22 5 x 30 5 x 45 110-130 DN 200 DN 200
SDC5 XVM 45-6 3 400 5 x 22 5 x 30 5 x 45 120-140 DN 200 DN 200
SDC5 XVM 45-7-2 3 400 5 x 30 5 x 40 5 x 45 130-150 DN 200 DN 200
SDC5 XVM 45-7 3 400 5 x 30 5 x 40 5 x 45 140-160 DN 200 DN 200
SDC5 XVM 45-8-2 3 400 5 x 30 5 x 40 5 x 45 150-170 DN 200 DN 200
SDC5 XVM 45-8 3 400 5 x 30 5 x 40 5 x 45 155-175 DN 200 DN 200
SDC5 XVM 45-9-2 3 400 5 x 30 5 x 40 5 x 45 170-190 DN 200 DN 200
SDC5 XVM 45-9 3 400 5 x 37 5 x 50 5 x 45 180-200 DN 200 DN 200
SDC5 XVM 45-10-2 3 400 5 x 37 5 x 50 5 x 45 190-210 DN 200 DN 200

SDC5 XVM 64-2-1 3 400 5 x 11 5 x 15 5 x 64 30-45 DN 300 DN 250


SDC5 XVM 64-2 3 400 5 x 11 5 x 15 5 x 64 35-55 DN 300 DN 250
SDC5 XVM 64-3-2 3 400 5 x 15 5 x 20 5 x 64 45-65 DN 300 DN 250
SDC5 XVM 64-3-1 3 400 5 x 15 5 x 20 5 x 64 50-70 DN 300 DN 250
SDC5 XVM 64-3 3 400 5 x 18,5 5 x 25 5 x 64 60-80 DN 300 DN 250
SDC5 XVM 64-4-2 3 400 5 x 18,5 5 x 25 5 x 64 65-85 DN 300 DN 250
SDC5 XVM 64-4-1 3 400 5 x 22 5 x 30 5 x 64 75-95 DN 300 DN 250
SDC5 XVM 64-4 3 400 5 x 22 5 x 30 5 x 64 80-100 DN 300 DN 250
SDC5 XVM 64-5-2 3 400 5 x 30 5 x 40 5 x 64 90-110 DN 300 DN 250
SDC5 XVM 64-5-1 3 400 5 x 30 5 x 40 5 x 64 95-115 DN 300 DN 250
SDC5 XVM 64-5 3 400 5 x 30 5 x 40 5 x 64 105-125 DN 300 DN 250

893
SDC5
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
SDC5 XVM 64-6-2 3 400 5 x 30 5 x 40 5 x 64 115-135 DN 300 DN 250
SDC5 XVM 64-6-1 3 400 5 x 37 5 x 50 5 x 64 120-140 DN 300 DN 250
SDC5 XVM 64-6 3 400 5 x 37 5 x 50 5 x 64 125-145 DN 300 DN 250
SDC5 XVM 64-7-2 3 400 5 x 37 5 x 50 5 x 64 135-155 DN 300 DN 250
SDC5 XVM 64-7-1 3 400 5 x 37 5 x 50 5 x 64 140-160 DN 300 DN 250
SDC5 XVM 64-7 3 400 5 x 45 5 x 60 5 x 64 150-170 DN 300 DN 250
SDC5 XVM 64-8-2 3 400 5 x 45 5 x 60 5 x 64 155-175 DN 300 DN 250
SDC5 XVM 64-8-1 3 400 5 x 45 5 x 60 5 x 64 165-185 DN 300 DN 250

SDC5 XVM 90-2-2 3 400 5 x 11 5 x 15 5 x 90 25-40 DN 300 DN 300


SDC5 XVM 90-2 3 400 5 x 15 5 x 20 5 x 90 40-55 DN 300 DN 300
SDC5 XVM 90-3-2 3 400 5 x 18,5 5 x 25 5 x 90 50-65 DN 300 DN 300
SDC5 XVM 90-3 3 400 5 x 22 5 x 30 5 x 90 60-80 DN 300 DN 300
SDC5 XVM 90-4-2 3 400 5 x 30 5 x 40 5 x 90 70-90 DN 300 DN 300
SDC5 XVM 90-4 3 400 5 x 30 5 x 40 5 x 90 85-105 DN 300 DN 300
SDC5 XVM 90-5-2 3 400 5 x 37 5 x 50 5 x 90 95-115 DN 300 DN 300
SDC5 XVM 90-5 3 400 5 x 37 5 x 50 5 x 90 110-130 DN 300 DN 300
SDC5 XVM 90-6-2 3 400 5 x 45 5 x 60 5 x 90 120-140 DN 300 DN 300
SDC5 XVM 90-6 3 400 5 x 45 5 x 60 5 x 90 130-150 DN 300 DN 300

894
VSD1
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 1 XVM 1-7 3 400 0,37 0,55 1,6 33 1" 1"
VSD 1 XVM 1-8 3 400 0,55 0,75 1,6 38 1" 1"
VSD 1 XVM 1-9 3 400 0,55 0,75 1,8 44 1” 1”
VSD 1 XVM 1-10 3 400 0,55 0,75 1,8 48 1” 1”
VSD 1 XVM 1-11 3 400 0,55 0,75 1,8 54 1” 1”
VSD 1 XVM 1-12 3 400 0,75 1 1,8 58 1” 1”
VSD 1 XVM 1-13 3 400 0,75 1 1,8 63 1” 1”
VSD 1 XVM 1-15 3 400 0,75 1 1,8 72 1” 1”
VSD 1 XVM 1-17 3 400 1,1 1,5 1,8 81 1” 1”
VSD 1 XVM 1-19 3 400 1,1 1,5 1,8 91 1” 1”
VSD 1 XVM 1-21 3 400 1,1 1,5 1,8 101 1” 1”
VSD 1 XVM 1-23 3 400 1,1 1,5 1,8 111 1” 1”
VSD 1 XVM 1-25 3 400 1,5 2 1,8 121 1” 1”
VSD 1 XVM 1-27 3 400 1,5 2 1,8 130 1” 1”
VSD 1 XVM 1-30 3 400 1,5 2 1,8 145 1” 1”
VSD 1 XVM 1-33 3 400 2,2 3 1,8 160 1” 1”
VSD 1 XVM 1-36 3 400 2,2 3 1,8 174 1” 1”

VSD 1 XVM 3-6 3 400 0,55 0,75 3 26 1” 1”


VSD 1 XVM 3-7 3 400 0,55 0,75 3 30 1” 1”
VSD 1 XVM 3-8 3 400 0,75 1 3 35 1” 1”
VSD 1 XVM 3-9 3 400 0,75 1 3 39 1” 1”
VSD 1 XVM 3-10 3 400 0,75 1 3 43 1” 1”
VSD 1 XVM 3-11 3 400 1,1 1,5 3 48 1” 1”
VSD 1 XVM 3-12 3 400 1,1 1,5 3 52 1” 1”
VSD 1 XVM 3-13 3 400 1,1 1,5 3 57 1” 1”
VSD 1 XVM 3-15 3 400 1,1 1,5 3 68 1” 1”
VSD 1 XVM 3-17 3 400 1,5 2 3 79 1” 1”
VSD 1 XVM 3-19 3 400 1,5 2 3 88 1” 1”
VSD 1 XVM 3-21 3 400 2,2 3 3 97 1” 1”
VSD 1 XVM 3-23 3 400 2,2 3 3 105 1” 1”
VSD 1 XVM 3-25 3 400 2,2 3 3 113 1” 1”
VSD 1 XVM 3-27 3 400 2,2 3 3 123 1” 1”
VSD 1 XVM 3-29 3 400 2,2 3 3 132 1” 1”
VSD 1 XVM 3-31 3 400 3 4 3 141 1” 1”
VSD 1 XVM 3-33 3 400 3 4 3 150 1” 1”
VSD 1 XVM 3-36 3 400 3 4 3 166 1” 1”

895
VSD1
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 1 XVM 5-6 3 400 1,1 1,5 5,5 28 1¼” 1¼”
VSD 1 XVM 5-7 3 400 1,1 1,5 5,5 33 1¼” 1¼”
VSD 1 XVM 5-8 3 400 1,1 1,5 5,5 38 1¼” 1¼”
VSD 1 XVM 5-9 3 400 1,5 2 5,5 42 1¼” 1¼”
VSD 1 XVM 5-10 3 400 1,5 2 5,5 47 1¼” 1¼”
VSD 1 XVM 5-11 3 400 2,2 3 5,5 52 1¼” 1¼”
VSD 1 XVM 5-12 3 400 2,2 3 5,5 58 1¼” 1¼”
VSD 1 XVM 5-13 3 400 2,2 3 5,5 64 1¼” 1¼”
VSD 1 XVM 5-14 3 400 2,2 3 5,5 69 1¼” 1¼”
VSD 1 XVM 5-15 3 400 2,2 3 5,5 75 1¼” 1¼”
VSD 1 XVM 5-16 3 400 2,2 3 5,5 80 1¼” 1¼”
VSD 1 XVM 5-18 3 400 3 4 5,5 90 1¼” 1¼”
VSD 1 XVM 5-20 3 400 3 4 5,5 99 1¼” 1¼”
VSD 1 XVM 5-22 3 400 4 5,5 5,5 110 1¼” 1¼”
VSD 1 XVM 5-24 3 400 4 5,5 5,5 120 1¼” 1¼”
VSD 1 XVM 5-26 3 400 4 5,5 5,5 131 1¼” 1¼”
VSD 1 XVM 5-29 3 400 4 5,5 5,5 150 1¼” 1¼”
VSD 1 XVM 5-32 3 400 5,5 7,5 5,5 166 1¼” 1¼”
VSD 1 XVM 5-36 3 400 5,5 7,5 5,5 188 1¼” 1¼”

VSD 1 XVM 10-3 3 400 1,1 1,5 10 25 2” 2”


VSD 1 XVM 10-4 3 400 1,5 2 10 32 2” 2”
VSD 1 XVM 10-5 3 400 2,2 3 10 39 2” 2”
VSD 1 XVM 10-6 3 400 2,2 3 10 46 2” 2”
VSD 1 XVM 10-7 3 400 3 4 10 54 2” 2”
VSD 1 XVM 10-8 3 400 3 4 10 62 2” 2”
VSD 1 XVM 10-9 3 400 3 4 10 71 2” 2”
VSD 1 XVM 10-10 3 400 4 5,5 10 81 2” 2”
VSD 1 XVM 10-12 3 400 4 5,5 10 95 2” 2”
VSD 1 XVM 10-14 3 400 5,5 7,5 10 110 2” 2”
VSD 1 XVM 10-16 3 400 5,5 7,5 10 125 2” 2”
VSD 1 XVM 10-18 3 400 7,5 10 10 144 2” 2”
VSD 1 XVM 10-20 3 400 7,5 10 10 160 2” 2”
VSD 1 XVM 10-22 3 400 7,5 10 10 178 2” 2”

896
VSD1
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 1 XVM 15-3 3 400 3 4 18 31 2" 2"
VSD 1 XVM 15-4 3 400 4 5,5 18 43 2” 2”
VSD 1 XVM 15-5 3 400 4 5,5 18 54 2” 2”
VSD 1 XVM 15-6 3 400 5,5 7,5 18 65 2” 2”
VSD 1 XVM 15-7 3 400 5,5 7,5 18 78 2” 2”
VSD 1 XVM 15-8 3 400 7,5 10 18 90 2” 2”
VSD 1 XVM 15-9 3 400 7,5 10 18 103 2” 2”
VSD 1 XVM 15-10 3 400 11 15 18 116 2” 2”
VSD 1 XVM 15-12 3 400 11 15 18 135 2” 2”
VSD 1 XVM 15-14 3 400 11 15 18 156 2” 2”
VSD 1 XVM 15-16 3 400 15 20 18 179 2” 2”
VSD 1 XVM 15-17 3 400 15 20 18 193 2” 2”

VSD 1 XVM 20-3 3 400 4 5,5 20 32 2" 2"


VSD 1 XVM 20-4 3 400 5,5 7,5 20 43 2” 2”
VSD 1 XVM 20-5 3 400 5,5 7,5 20 55 2” 2”
VSD 1 XVM 20-6 3 400 7,5 10 20 66 2” 2”
VSD 1 XVM 20-7 3 400 7,5 10 20 77 2” 2”
VSD 1 XVM 20-8 3 400 11 15 20 89 2” 2”
VSD 1 XVM 20-10 3 400 11 15 20 112 2” 2”
VSD 1 XVM 20-12 3 400 15 20 20 136 2” 2”
VSD 1 XVM 20-14 3 400 15 20 20 161 2” 2”
VSD 1 XVM 20-16 3 400 18,5 25 20 186 2” 2”
VSD 1 XVM 20-17 3 400 18,5 25 20 202 2” 2”

VSD 1 XVM 32-2 3 400 4 5,5 30 26 DN 65 DN 65


VSD 1 XVM 32-3-2 3 400 4 5,5 30 34 DN 65 DN 65
VSD 1 XVM 32-3 3 400 5,5 7,5 30 39 DN 65 DN 65
VSD 1 XVM 32-4-2 3 400 7,5 10 30 47 DN 65 DN 65
VSD 1 XVM 32-4 3 400 7,5 10 30 53 DN 65 DN 65
VSD 1 XVM 32-5-2 3 400 11 15 30 61 DN 65 DN 65
VSD 1 XVM 32-5 3 400 11 15 30 66 DN 65 DN 65
VSD 1 XVM 32-6-2 3 400 11 15 30 75 DN 65 DN 65
VSD 1 XVM 32-6 3 400 11 15 30 83 DN 65 DN 65
VSD 1 XVM 32-7-2 3 400 15 20 30 90 DN 65 DN 65
VSD 1 XVM 32-7 3 400 15 20 30 97 DN 65 DN 65

897
VSD1
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 1 XVM 32-8-2 3 400 15 20 30 104 DN 65 DN 65
VSD 1 XVM 32-8 3 400 15 20 30 111 DN 65 DN 65
VSD 1 XVM 32-9-2 3 400 18,5 25 30 119 DN 65 DN 65
VSD 1 XVM 32-9 3 400 18,5 25 30 126 DN 65 DN 65
VSD 1 XVM 32-10-2 3 400 18,5 25 30 135 DN 65 DN 65
VSD 1 XVM 32-10 3 400 18,5 25 30 142 DN 65 DN 65
VSD 1 XVM 32-11-2 3 400 22 30 30 149 DN 65 DN 65
VSD 1 XVM 32-11 3 400 22 30 30 157 DN 65 DN 65
VSD 1 XVM 32-12-2 3 400 22 30 30 165 DN 65 DN 65
VSD 1 XVM 32-12 3 400 22 30 30 171 DN 65 DN 65
VSD 1 XVM 32-13-2 3 400 30 40 30 179 DN 65 DN 65
VSD 1 XVM 32-13 3 400 30 40 30 187 DN 65 DN 65
VSD 1 XVM 32-14-2 3 400 30 40 30 197 DN 65 DN 65

VSD 1 XVM 45-2-2 3 400 5,5 7,5 45 30 DN 80 DN 80


VSD 1 XVM 45-2 3 400 7,5 10 45 39 DN 80 DN 80
VSD 1 XVM 45-3-2 3 400 11 15 45 50 DN 80 DN 80
VSD 1 XVM 45-3 3 400 11 15 45 58 DN 80 DN 80
VSD 1 XVM 45-4-2 3 400 15 20 45 69 DN 80 DN 80
VSD 1 XVM 45-4 3 400 15 20 45 77 DN 80 DN 80
VSD 1 XVM 45-5-2 3 400 18,5 25 45 88 DN 80 DN 80
VSD 1 XVM 45-5 3 400 18,5 25 45 97 DN 80 DN 80
VSD 1 XVM 45-6-2 3 400 22 30 45 109 DN 80 DN 80
VSD 1 XVM 45-6 3 400 22 30 45 118 DN 80 DN 80
VSD 1 XVM 45-7-2 3 400 30 40 45 128 DN 80 DN 80
VSD 1 XVM 45-7 3 400 30 40 45 136 DN 80 DN 80
VSD 1 XVM 45-8-2 3 400 30 40 45 147 DN 80 DN 80
VSD 1 XVM 45-8 3 400 30 40 45 155 DN 80 DN 80
VSD 1 XVM 45-9-2 3 400 30 40 45 169 DN 80 DN 80
VSD 1 XVM 45-9 3 400 37 50 45 177 DN 80 DN 80
VSD 1 XVM 45-10-2 3 400 37 50 45 188 DN 80 DN 80

VSD 1 XVM 64-2-2 3 400 7,5 10 64 26 DN 100 DN 100


VSD 1 XVM 64-2-1 3 400 11 15 64 34 DN 100 DN 100
VSD 1 XVM 64-2 3 400 11 15 64 40 DN 100 DN 100

898
VSD1
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 1 XVM 64-3-2 3 400 15 20 64 46 DN 100 DN 100
VSD 1 XVM 64-3-1 3 400 15 20 64 53 DN 100 DN 100
VSD 1 XVM 64-3 3 400 18,5 25 64 60 DN 100 DN 100
VSD 1 XVM 64-4-2 3 400 18,5 25 64 66 DN 100 DN 100
VSD 1 XVM 64-4-1 3 400 22 30 64 73 DN 100 DN 100
VSD 1 XVM 64-4 3 400 22 30 64 80 DN 100 DN 100
VSD 1 XVM 64-5-2 3 400 30 40 64 89 DN 100 DN 100
VSD 1 XVM 64-5-1 3 400 30 40 64 96 DN 100 DN 100
VSD 1 XVM 64-5 3 400 30 40 64 103 DN 100 DN 100
VSD 1 XVM 64-6-2 3 400 30 40 64 112 DN 100 DN 100
VSD 1 XVM 64-6-1 3 400 37 50 64 118 DN 100 DN 100
VSD 1 XVM 64-6 3 400 37 50 64 125 DN 100 DN 100
VSD 1 XVM 64-7-2 3 400 37 50 64 133 DN 100 DN 100
VSD 1 XVM 64-7-1 3 400 37 50 64 140 DN 100 DN 100
VSD 1 XVM 64-7 3 400 45 60 64 147 DN 100 DN 100
VSD 1 XVM 64-8-2 3 400 45 60 64 155 DN 100 DN 100
VSD 1 XVM 64-8-1 3 400 45 60 64 162 DN 100 DN 100

VSD 1 XVM 90-2-2 3 400 11 15 85 30 DN 100 DN 100


VSD 1 XVM 90-2 3 400 15 20 85 43 DN 100 DN 100
VSD 1 XVM 90-3-2 3 400 18,5 25 85 52 DN 100 DN 100
VSD 1 XVM 90-3 3 400 22 30 85 64 DN 100 DN 100
VSD 1 XVM 90-4-2 3 400 30 40 85 76 DN 100 DN 100
VSD 1 XVM 90-4 3 400 30 40 85 88 DN 100 DN 100
VSD 1 XVM 90-5-2 3 400 37 50 85 100 DN 100 DN 100
VSD 1 XVM 90-5 3 400 37 50 85 113 DN 100 DN 100
VSD 1 XVM 90-6-2 3 400 45 60 85 124 DN 100 DN 100
VSD 1 XVM 90-6 3 400 45 60 85 135 DN 100 DN 100

899
VSD1
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD1 WTM 32-160/3 3 400 3 4 18 25 DN 65 DN 50
VSD1 WTM 32-200/3 3 400 3 4 19 30 DN 65 DN 50
VSD1 WTM 32-200/4 3 400 4 5,5 19 40 DN 65 DN 50
VSD1 WTM 32-250/5,5 3 400 5,5 7,5 18 55 DN 65 DN 50
VSD1 WTM 32-250/7,5 3 400 7,5 10 20 70 DN 65 DN 50
VSD1 WTM 40-160/3 3 400 3 4 28 25 DN 80 DN 65
VSD1 WTM 40-160/4 3 400 4 5,5 32 30 DN 80 DN 65
VSD1 WTM 40-200/5,5 3 400 5,5 7,5 32 35 DN 80 DN 65
VSD1 WTM 40-200/7,5 3 400 7,5 10 32 45 DN 80 DN 65
VSD1 WTM 40-250/9,2 3 400 9,2 12,5 35 50 DN 80 DN 65
VSD1 WTM 40-250/11 3 400 11 15 35 55 DN 80 DN 65
VSD1 WTM 40-250/15 3 400 15 20 40 65 DN 80 DN 65
VSD1 WTM 50-160/5,5 3 400 5,5 7,5 60 25 DN 80 DN 65
VSD1 WTM 50-160/7,5 3 400 7,5 10 65 30 DN 80 DN 65
VSD1 WTM 50-200/9,2 3 400 9,2 12,5 60 38 DN 80 DN 65
VSD1 WTM 50-200/11 3 400 11 15 60 45 DN 80 DN 65
VSD1 WTM 50-250/15 3 400 15 20 60 55 DN 80 DN 65
VSD1 WTM 50-250/18,5 3 400 18,5 25 70 60 DN 80 DN 65
VSD1 WTM 50-250/22 3 400 22 30 70 70 DN 80 DN 65
VSD1 WTM 65-125/7,5 3 400 7,5 10 90 22 DN 100 DN 80
VSD1 WTM 65-160/9,2 3 400 9,2 12,5 95 25 DN 100 DN 80
VSD1 WTM 65-160/11 3 400 11 15 95 30 DN 100 DN 80
VSD1 WTM 65-160/15 3 400 15 20 105 35 DN 100 DN 80
VSD1 WTM 65-200/15 3 400 15 20 85 40 DN 100 DN 80
VSD1 WTM 65-200/18,5 3 400 18,5 25 85 47 DN 100 DN 80
VSD1 WTM 65-200/22 3 400 22 30 85 54 DN 100 DN 80
VSD1 WTM 65-250/22 3 400 22 30 100 50 DN 100 DN 80
VSD1 WTM 65-250/30 3 400 30 40 110 63 DN 100 DN 80
VSD1 WTM 65-250/37 3 400 37 50 110 77 DN 100 DN 80
VSD1 WTM 80-160/11 3 400 11 15 140 22 DN 125 DN 100
VSD1 WTM 80-160/15 3 400 15 20 140 27 DN 125 DN 100
VSD1 WTM 80-160/18,5 3 400 18,5 25 150 32 DN 125 DN 100
VSD1 WTM 80-200/22 3 400 22 30 160 36 DN 125 DN 100
VSD1 WTM 80-200/30 3 400 30 40 160 50 DN 125 DN 100
VSD1 WTM 80-250/37 3 400 37 50 150 58 DN 125 DN 100
VSD1 WTM 80-250/45 3 400 45 60 150 70 DN 125 DN 100
VSD1 WTM 80-250/55 3 400 55 75 165 80 DN 125 DN 100

900
VSD2
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 2 XVM 1-7 3 400 2 x 0,37 2 x 0,55 2 x 1,6 33 1½” 1½”
VSD 2 XVM 1-8 3 400 2 x 0,55 2 x 0,75 2 x 1,6 38 1½” 1½”
VSD 2 XVM 1-9 3 400 2 x 0,55 2 x 0,75 2 x 1,6 44 1½” 1½”
VSD 2 XVM 1-10 3 400 2 x 0,55 2 x 0,75 2 x 1,6 48 1½” 1½”
VSD 2 XVM 1-11 3 400 2 x 0,55 2 x 0,75 2 x 1,6 54 1½” 1½”
VSD 2 XVM 1-12 3 400 2 x 0,75 2x1 2 x 1,6 58 1½” 1½”
VSD 2 XVM 1-13 3 400 2 x 0,75 2x1 2 x 1,6 63 1½” 1½”
VSD 2 XVM 1-15 3 400 2 x 0,75 2x1 2 x 1,6 72 1½” 1½”
VSD 2 XVM 1-17 3 400 2 x 1,1 2 x 1,5 2 x 1,6 81 1½” 1½”
VSD 2 XVM 1-19 3 400 2 x 1,1 2 x 1,5 2 x 1,6 91 1½” 1½”
VSD 2 XVM 1-21 3 400 2 x 1,1 2 x 1,5 2 x 1,6 101 1½” 1½”
VSD 2 XVM 1-23 3 400 2 x 1,1 2 x 1,5 2 x 1,6 111 1½” 1½”
VSD 2 XVM 1-25 3 400 2 x 1,5 2x2 2 x 1,6 121 1½” 1½”
VSD 2 XVM 1-27 3 400 2 x 1,5 2x2 2 x 1,6 130 1½” 1½”
VSD 2 XVM 1-30 3 400 2 x 1,5 2x2 2 x 1,6 145 1½” 1½”
VSD 2 XVM 1-33 3 400 2 x 2,2 2x3 2 x 1,6 160 1½” 1½”
VSD 2 XVM 1-36 3 400 2 x 2,2 2x3 2 x 1,6 174 1½” 1½”

VSD 2 XVM 3-6 3 400 2 x 0,55 2 x 0,75 2x3 26 1½” 1½”


VSD 2 XVM 3-7 3 400 2 x 0,55 2 x 0,75 2x3 30 1½” 1½”
VSD 2 XVM 3-8 3 400 2 x 0,75 2x1 2x3 35 1½” 1½”
VSD 2 XVM 3-9 3 400 2 x 0,75 2x1 2x3 39 1½” 1½”
VSD 2 XVM 3-10 3 400 2 x 0,75 2x1 2x3 43 1½” 1½”
VSD 2 XVM 3-11 3 400 2 x 1,1 2 x 1,5 2x3 48 1½” 1½”
VSD 2 XVM 3-12 3 400 2 x 1,1 2 x 1,5 2x3 52 1½” 1½”
VSD 2 XVM 3-13 3 400 2 x 1,1 2 x 1,5 2x3 57 1½” 1½”
VSD 2 XVM 3-15 3 400 2 x 1,1 2 x 1,5 2x3 68 1½” 1½”
VSD 2 XVM 3-17 3 400 2 x 1,5 2x2 2x3 79 1½” 1½”
VSD 2 XVM 3-19 3 400 2 x 1,5 2x2 2x3 88 1½” 1½”
VSD 2 XVM 3-21 3 400 2 x 2,2 2x3 2x3 97 1½” 1½”
VSD 2 XVM 3-23 3 400 2 x 2,2 2x3 2x3 105 1½” 1½”
VSD 2 XVM 3-25 3 400 2 x 2,2 2x3 2x3 113 1½” 1½”
VSD 2 XVM 3-27 3 400 2 x 2,2 2x3 2x3 123 1½” 1½”
VSD 2 XVM 3-29 3 400 2 x 2,2 2x3 2x3 132 1½” 1½”
VSD 2 XVM 3-31 3 400 2x3 2x4 2x3 141 1½” 1½”
VSD 2 XVM 3-33 3 400 2x3 2x4 2x3 150 1½” 1½”
VSD 2 XVM 3-36 3 400 2x3 2x4 2x3 166 1½” 1½”

901
VSD2
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 2 XVM 5-6 3 400 2 x 1,1 2 x 1,5 2 x 5,5 28 2" 2"
VSD 2 XVM 5-7 3 400 2 x 1,1 2 x 1,5 2 x 5,5 33 2" 2"
VSD 2 XVM 5-8 3 400 2 x 1,1 2 x 1,5 2 x 5,5 38 2” 2”
VSD 2 XVM 5-9 3 400 2 x 1,5 2x2 2 x 5,5 42 2” 2”
VSD 2 XVM 5-10 3 400 2 x 1,5 2x2 2 x 5,5 47 2” 2”
VSD 2 XVM 5-11 3 400 2 x 2,2 2x3 2 x 5,5 52 2” 2”
VSD 2 XVM 5-12 3 400 2 x 2,2 2x3 2 x 5,5 58 2” 2”
VSD 2 XVM 5-13 3 400 2 x 2,2 2x3 2 x 5,5 64 2” 2”
VSD 2 XVM 5-14 3 400 2 x 2,2 2x3 2 x 5,5 69 2” 2”
VSD 2 XVM 5-15 3 400 2 x 2,2 2x3 2 x 5,5 75 2” 2”
VSD 2 XVM 5-16 3 400 2 x 2,2 2x3 2 x 5,5 80 2” 2”
VSD 2 XVM 5-18 3 400 2x3 2x4 2 x 5,5 90 2” 2”
VSD 2 XVM 5-20 3 400 2x3 2x4 2 x 5,5 99 2” 2”
VSD 2 XVM 5-22 3 400 2x4 2 x 5,5 2 x 5,5 110 2” 2”
VSD 2 XVM 5-24 3 400 2x4 2 x 5,5 2 x 5,5 120 2” 2”
VSD 2 XVM 5-26 3 400 2x4 2 x 5,5 2 x 5,5 131 2” 2”
VSD 2 XVM 5-29 3 400 2x4 2 x 5,5 2 x 5,5 150 2” 2”
VSD 2 XVM 5-32 3 400 2 x 5,5 2 x 7,5 2 x 5,5 166 2” 2”
VSD 2 XVM 5-36 3 400 2 x 5,5 2 x 7,5 2 x 5,5 188 2” 2”

VSD 2 XVM 10-3 3 400 2 x 1,1 2 x 1,5 2 x 10 25 2½” 2½”


VSD 2 XVM 10-4 3 400 2 x 1,5 2x2 2 x 10 32 2½” 2½”
VSD 2 XVM 10-5 3 400 2 x 2,2 2x3 2 x 10 39 2½” 2½”
VSD 2 XVM 10-6 3 400 2 x 2,2 2x3 2 x 10 46 2½” 2½”
VSD 2 XVM 10-7 3 400 2x3 2x4 2 x 10 54 2½” 2½”
VSD 2 XVM 10-8 3 400 2x3 2x4 2 x 10 62 2½” 2½”
VSD 2 XVM 10-9 3 400 2x3 2x4 2 x 10 71 2½” 2½”
VSD 2 XVM 10-10 3 400 2x4 2 x 5,5 2 x 10 81 2½” 2½”
VSD 2 XVM 10-12 3 400 2x4 2 x 5,5 2 x 10 95 2½” 2½”
VSD 2 XVM 10-14 3 400 2 x 5,5 2 x 7,5 2 x 10 110 2½” 2½”
VSD 2 XVM 10-16 3 400 2 x 5,5 2 x 7,5 2 x 10 125 2½” 2½”
VSD 2 XVM 10-18 3 400 2 x 7,5 2 x 10 2 x 10 144 2½” 2½”
VSD 2 XVM 10-20 3 400 2 x 7,5 2 x 10 2 x 10 160 2½” 2½”
VSD 2 XVM 10-22 3 400 2 x 7,5 2 x 10 2 x 10 178 2½” 2½”

902
VSD2
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 2 XVM 15-3 3 400 2x3 2x4 2 x 16 31 3" 2 1/2"
VSD 2 XVM 15-4 3 400 2x4 2 x 5,5 2 x 16 43 3” 2½”
VSD 2 XVM 15-5 3 400 2x4 2 x 5,5 2 x 16 54 3” 2½”
VSD 2 XVM 15-6 3 400 2 x 5,5 2 x 7,5 2 x 16 65 3” 2½”
VSD 2 XVM 15-7 3 400 2 x 5,5 2 x 7,5 2 x 16 78 3” 2½”
VSD 2 XVM 15-8 3 400 2 x 7,5 2 x 10 2 x 16 90 3” 2½”
VSD 2 XVM 15-9 3 400 2 x 7,5 2 x 10 2 x 16 103 3” 2½”
VSD 2 XVM 15-10 3 400 2 x 11 2 x 15 2 x 16 116 3” 2½”
VSD 2 XVM 15-12 3 400 2 x 11 2 x 15 2 x 16 135 3” 2½”
VSD 2 XVM 15-14 3 400 2 x 11 2 x 15 2 x 16 156 3” 2½”
VSD 2 XVM 15-16 3 400 2 x 15 2 x 20 2 x 16 179 3” 2½”
VSD 2 XVM 15-17 3 400 2 x 15 2 x 20 2 x 16 193 3” 2½”

VSD 2 XVM 20-3 3 400 2x4 2 x 5,5 2 x 20 32 3" 3"


VSD 2 XVM 20-4 3 400 2 x 5,5 2 x 7,5 2 x 20 43 3” 3”
VSD 2 XVM 20-5 3 400 2 x 5,5 2 x 7,5 2 x 20 55 3” 3”
VSD 2 XVM 20-6 3 400 2 x 7,5 2 x 10 2 x 20 66 3” 3”
VSD 2 XVM 20-7 3 400 2 x 7,5 2 x 10 2 x 20 77 3” 3”
VSD 2 XVM 20-8 3 400 2 x 11 2 x 15 2 x 20 89 3” 3”
VSD 2 XVM 20-10 3 400 2 x 11 2 x 15 2 x 20 112 3” 3”
VSD 2 XVM 20-12 3 400 2 x 15 2 x 20 2 x 20 136 3” 3”
VSD 2 XVM 20-14 3 400 2 x 15 2 x 20 2 x 20 161 3” 3”
VSD 2 XVM 20-16 3 400 2 x 18,5 2 x 25 2 x 20 186 3” 3”
VSD 2 XVM 20-17 3 400 2 x 18,5 2 x 25 2 x 20 202 3” 3”

VSD 2 XVM 32-2 3 400 2x4 2 x 5,5 2 x 30 26 DN 100 DN 100


VSD 2 XVM 32-3-2 3 400 2x4 2 x 5,5 2 x 30 34 DN 100 DN 100
VSD 2 XVM 32-3 3 400 2 x 5,5 2 x 7,5 2 x 30 39 DN 100 DN 100
VSD 2 XVM 32-4-2 3 400 2 x 7,5 2 x 10 2 x 30 47 DN 100 DN 100
VSD 2 XVM 32-4 3 400 2 x 7,5 2 x 10 2 x 30 53 DN 100 DN 100
VSD 2 XVM 32-5-2 3 400 2 x 11 2 x 15 2 x 30 61 DN 100 DN 100
VSD 2 XVM 32-5 3 400 2 x 11 2 x 15 2 x 30 66 DN 100 DN 100
VSD 2 XVM 32-6-2 3 400 2 x 11 2 x 15 2 x 30 75 DN 100 DN 100
VSD 2 XVM 32-6 3 400 2 x 11 2 x 15 2 x 30 83 DN 100 DN 100
VSD 2 XVM 32-7-2 3 400 2 x 15 2 x 20 2 x 30 90 DN 100 DN 100
VSD 2 XVM 32-7 3 400 2 x 15 2 x 20 2 x 30 97 DN 100 DN 100

903
VSD2
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 2 XVM 32-8-2 3 400 2 x 15 2 x 20 2 x 30 104 DN 100 DN 100
VSD 2 XVM 32-8 3 400 2 x 15 2 x 20 2 x 30 111 DN 100 DN 100
VSD 2 XVM 32-9-2 3 400 2 x 18,5 2 x 25 2 x 30 119 DN 100 DN 100
VSD 2 XVM 32-9 3 400 2 x 18,5 2 x 25 2 x 30 126 DN 100 DN 100
VSD 2 XVM 32-10-2 3 400 2 x 18,5 2 x 25 2 x 30 135 DN 100 DN 100
VSD 2 XVM 32-10 3 400 2 x 18,5 2 x 25 2 x 30 142 DN 100 DN 100
VSD 2 XVM 32-11-2 3 400 2 x 22 2 x 30 2 x 30 149 DN 100 DN 100
VSD 2 XVM 32-11 3 400 2 x 22 2 x 30 2 x 30 157 DN 100 DN 100
VSD 2 XVM 32-12-2 3 400 2 x 22 2 x 30 2 x 30 165 DN 100 DN 100
VSD 2 XVM 32-12 3 400 2 x 22 2 x 30 2 x 30 171 DN 100 DN 100
VSD 2 XVM 32-13-2 3 400 2 x 30 2 x 40 2 x 30 179 DN 100 DN 100
VSD 2 XVM 32-13 3 400 2 x 30 2 x 40 2 x 30 187 DN 100 DN 100
VSD 2 XVM 32-14-2 3 400 2 x 30 2 x 40 2 x 30 197 DN 100 DN 100

VSD 2 XVM 45-2-2 3 400 2 x 5,5 2 x 7,5 2 x 45 30 DN 125 DN 125


VSD 2 XVM 45-2 3 400 2 x 7,5 2 x 10 2 x 45 39 DN 125 DN 125
VSD 2 XVM 45-3-2 3 400 2 x 11 2 x 15 2 x 45 50 DN 125 DN 125
VSD 2 XVM 45-3 3 400 2 x 11 2 x 15 2 x 45 58 DN 125 DN 125
VSD 2 XVM 45-4-2 3 400 2 x 15 2 x 20 2 x 45 69 DN 125 DN 125
VSD 2 XVM 45-4 3 400 2 x 15 2 x 20 2 x 45 77 DN 125 DN 125
VSD 2 XVM 45-5-2 3 400 2 x 18,5 2 x 25 2 x 45 88 DN 125 DN 125
VSD 2 XVM 45-5 3 400 2 x 18,5 2 x 25 2 x 45 97 DN 125 DN 125
VSD 2 XVM 45-6-2 3 400 2 x 22 2 x 30 2 x 45 109 DN 125 DN 125
VSD 2 XVM 45-6 3 400 2 x 22 2 x 30 2 x 45 118 DN 125 DN 125
VSD 2 XVM 45-7-2 3 400 2 x 30 2 x 40 2 x 45 128 DN 125 DN 125
VSD 2 XVM 45-7 3 400 2 x 30 2 x 40 2 x 45 136 DN 125 DN 125
VSD 2 XVM 45-8-2 3 400 2 x 30 2 x 40 2 x 45 147 DN 125 DN 125
VSD 2 XVM 45-8 3 400 2 x 30 2 x 40 2 x 45 155 DN 125 DN 125
VSD 2 XVM 45-9-2 3 400 2 x 30 2 x 40 2 x 45 169 DN 125 DN 125
VSD 2 XVM 45-9 3 400 2 x 37 2 x 50 2 x 45 177 DN 125 DN 125
VSD 2 XVM 45-10-2 3 400 2 x 37 2 x 50 2 x 45 188 DN 125 DN 125

904
VSD2
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 2 XVM 64-2-2 3 400 2 x 7,5 2 x 10 2 x 64 26 DN 150 DN 150
VSD 2 XVM 64-2-1 3 400 2 x 11 2 x 15 2 x 64 34 DN 150 DN 150
VSD 2 XVM 64-2 3 400 2 x 11 2 x 15 2 x 64 40 DN 150 DN 150
VSD 2 XVM 64-3-2 3 400 2 x 15 2 x 20 2 x 64 46 DN 150 DN 150
VSD 2 XVM 64-3-1 3 400 2 x 15 2 x 20 2 x 64 53 DN 150 DN 150
VSD 2 XVM 64-3 3 400 2 x 18,5 2 x 25 2 x 64 60 DN 150 DN 150
VSD 2 XVM 64-4-2 3 400 2 x 18,5 2 x 25 2 x 64 66 DN 150 DN 150
VSD 2 XVM 64-4-1 3 400 2 x 22 2 x 30 2 x 64 73 DN 150 DN 150
VSD 2 XVM 64-4 3 400 2 x 22 2 x 30 2 x 64 80 DN 150 DN 150
VSD 2 XVM 64-5-2 3 400 2 x 30 2 x 40 2 x 64 89 DN 150 DN 150
VSD 2 XVM 64-5-1 3 400 2 x 30 2 x 40 2 x 64 96 DN 150 DN 150
VSD 2 XVM 64-5 3 400 2 x 30 2 x 40 2 x 64 103 DN 150 DN 150
VSD 2 XVM 64-6-2 3 400 2 x 30 2 x 40 2 x 64 112 DN 150 DN 150
VSD 2 XVM 64-6-1 3 400 2 x 37 2 x 50 2 x 64 118 DN 150 DN 150
VSD 2 XVM 64-6 3 400 2 x 37 2 x 50 2 x 64 125 DN 150 DN 150
VSD 2 XVM 64-7-2 3 400 2 x 37 2 x 50 2 x 64 133 DN 150 DN 150
VSD 2 XVM 64-7-1 3 400 2 x 37 2 x 50 2 x 64 140 DN 150 DN 150
VSD 2 XVM 64-7 3 400 2 x 45 2 x 60 2 x 64 147 DN 150 DN 150
VSD 2 XVM 64-8-2 3 400 2 x 45 2 x 60 2 x 64 155 DN 150 DN 150
VSD 2 XVM 64-8-1 3 400 2 x 45 2 x 60 2 x 64 162 DN 150 DN 150

VSD 2 XVM 90-2-2 3 400 2 x 11 2 x 15 2 x 85 30 DN 150 DN 150


VSD 2 XVM 90-2 3 400 2 x 15 2 x 20 2 x 85 43 DN 150 DN 150
VSD 2 XVM 90-3-2 3 400 2 x 18,5 2 x 25 2 x 85 52 DN 150 DN 150
VSD 2 XVM 90-3 3 400 2 x 22 2 x 30 2 x 85 64 DN 150 DN 150
VSD 2 XVM 90-4-2 3 400 2 x 30 2 x 40 2 x 85 76 DN 150 DN 150
VSD 2 XVM 90-4 3 400 2 x 30 2 x 40 2 x 85 88 DN 150 DN 150
VSD 2 XVM 90-5-2 3 400 2 x 37 2 x 50 2 x 85 100 DN 150 DN 150
VSD 2 XVM 90-5 3 400 2 x 37 2 x 50 2 x 85 113 DN 150 DN 150
VSD 2 XVM 90-6-2 3 400 2 x 45 2 x 60 2 x 85 124 DN 150 DN 150
VSD 2 XVM 90-6 3 400 2 x 45 2 x 60 2 x 85 135 DN 150 DN 150

905
VSD2
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD2 WTM 32-160/3 3 400 2x3 2x4 2 x 18 25 DN 80 DN 80
VSD2 WTM 32-200/3 3 400 2x3 2x4 2 x 19 30 DN 80 DN 80
VSD2 WTM 32-200/4 3 400 2x4 2 x 5,5 2 x 19 40 DN 80 DN 80
VSD2 WTM 32-250/5,5 3 400 2 x 5,5 2 x 7,5 2 x 18 55 DN 80 DN 80
VSD2 WTM 32-250/7,5 3 400 2 x 7,5 2 x 10 2 x 20 70 DN 80 DN 80
VSD2 WTM 40-160/3 3 400 2x3 2x4 2 x 28 25 DN 100 DN 100
VSD2 WTM 40-160/4 3 400 2x4 2 x 5,5 2 x 32 30 DN 100 DN 100
VSD2 WTM 40-200/5,5 3 400 2 x 5,5 2 x 7,5 2 x 32 35 DN 100 DN 100
VSD2 WTM 40-200/7,5 3 400 2 x 7,5 2 x 10 2 x 32 45 DN 100 DN 100
VSD2 WTM 40-250/9,2 3 400 2 x 9,2 2 x 12,5 2 x 35 50 DN 100 DN 100
VSD2 WTM 40-250/11 3 400 2 x 11 2 x 15 2 x 35 55 DN 100 DN 100
VSD2 WTM 40-250/15 3 400 2 x 15 2 x 20 2 x 40 65 DN 100 DN 100
VSD2 WTM 50-160/5,5 3 400 2 x 5,5 2 x 7,5 2 x 60 25 DN 125 DN 125
VSD2 WTM 50-160/7,5 3 400 2 x 7,5 2 x 10 2 x 65 30 DN 125 DN 125
VSD2 WTM 50-200/9,2 3 400 2 x 9,2 2 x 12,5 2 x 60 38 DN 125 DN 125
VSD2 WTM 50-200/11 3 400 2 x 11 2 x 15 2 x 60 45 DN 125 DN 125
VSD2 WTM 50-250/15 3 400 2 x 15 2 x 20 2 x 60 55 DN 125 DN 125
VSD2 WTM 50-250/18,5 3 400 2 x 18,5 2 x 25 2 x 70 60 DN 125 DN 125
VSD2 WTM 50-250/22 3 400 2 x 22 2 x 30 2 x 70 70 DN 125 DN 125
VSD2 WTM 65-125/7,5 3 400 2 x 7,5 2 x 10 2 x 90 22 DN 200 DN 200
VSD2 WTM 65-160/9,2 3 400 2 x 9,2 2 x 12,5 2 x 95 25 DN 200 DN 200
VSD2 WTM 65-160/11 3 400 2 x 11 2 x 15 2 x 95 30 DN 200 DN 200
VSD2 WTM 65-160/15 3 400 2 x 15 2 x 20 2 x 105 35 DN 200 DN 200
VSD2 WTM 65-200/15 3 400 2 x 15 2 x 20 2 x 85 40 DN 200 DN 200
VSD2 WTM 65-200/18,5 3 400 2 x 18,5 2 x 25 2 x 85 47 DN 200 DN 200
VSD2 WTM 65-200/22 3 400 2 x 22 2 x 30 2 x 85 54 DN 200 DN 200
VSD2 WTM 65-250/22 3 400 2 x 22 2 x 30 2 x 100 50 DN 200 DN 200
VSD2 WTM 65-250/30 3 400 2 x 30 2 x 40 2 x 110 63 DN 200 DN 200
VSD2 WTM 65-250/37 3 400 2 x 37 2 x 50 2 x 110 77 DN 200 DN 200
VSD2 WTM 80-160/11 3 400 2 x 11 2 x 15 2 x 140 22 DN 250 DN 200
VSD2 WTM 80-160/15 3 400 2 x 15 2 x 20 2 x 140 27 DN 250 DN 200
VSD2 WTM 80-160/18,5 3 400 2 x 18,5 2 x 25 2 x 150 32 DN 250 DN 200
VSD2 WTM 80-200/22 3 400 2 x 22 2 x 30 2 x 160 36 DN 250 DN 200
VSD2 WTM 80-200/30 3 400 2 x 30 2 x 40 2 x 160 50 DN 250 DN 200
VSD2 WTM 80-250/37 3 400 2 x 37 2 x 50 2 x 150 58 DN 250 DN 200
VSD2 WTM 80-250/45 3 400 2 x 45 2 x 60 2 x 150 70 DN 250 DN 200
VSD2 WTM 80-250/55 3 400 2 x 55 2 x 75 2 x 165 80 DN 250 DN 200

906
VSD3
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 3 XVM 1-7 3 400 3 x 0,37 3 x 0,55 3 x 1,6 33 2" 2"
VSD 3 XVM 1-8 3 400 3 x 0,55 3 x 0,75 3 x 1,6 38 2” 2”
VSD 3 XVM 1-9 3 400 3 x 0,55 3 x 0,75 3 x 1,6 44 2” 2”
VSD 3 XVM 1-10 3 400 3 x 0,55 3 x 0,75 3 x 1,6 48 2” 2”
VSD 3 XVM 1-11 3 400 3 x 0,55 3 x 0,75 3 x 1,6 54 2” 2”
VSD 3 XVM 1-12 3 400 3 x 0,75 3x1 3 x 1,6 58 2” 2”
VSD 3 XVM 1-13 3 400 3 x 0,75 3x1 3 x 1,6 63 2” 2”
VSD 3 XVM 1-15 3 400 3 x 0,75 3x1 3 x 1,6 72 2” 2”
VSD 3 XVM 1-17 3 400 3 x 1,1 3 x 1,5 3 x 1,6 81 2” 2”
VSD 3 XVM 1-19 3 400 3 x 1,1 3 x 1,5 3 x 1,6 91 2” 2”
VSD 3 XVM 1-21 3 400 3 x 1,1 3 x 1,5 3 x 1,6 101 2” 2”
VSD 3 XVM 1-23 3 400 3 x 1,1 3 x 1,5 3 x 1,6 111 2” 2”
VSD 3 XVM 1-25 3 400 3 x 1,5 3x2 3 x 1,6 121 2” 2”
VSD 3 XVM 1-27 3 400 3 x 1,5 3x2 3 x 1,6 130 2” 2”
VSD 3 XVM 1-30 3 400 3 x 1,5 3x2 3 x 1,6 145 2” 2”
VSD 3 XVM 1-33 3 400 3 x 2,2 3x3 3 x 1,6 160 2” 2”
VSD 3 XVM 1-36 3 400 3 x 2,2 3x3 3 x 1,6 174 2” 2”

VSD 3 XVM 3-6 3 400 3 x 0,55 3 x 0,75 3x3 26 2” 2”


VSD 3 XVM 3-7 3 400 3 x 0,55 3 x 0,75 3x3 30 2” 2”
VSD 3 XVM 3-8 3 400 3 x 0,75 3x1 3x3 35 2” 2”
VSD 3 XVM 3-9 3 400 3 x 0,75 3x1 3x3 39 2” 2”
VSD 3 XVM 3-10 3 400 3 x 0,75 3x1 3x3 43 2” 2”
VSD 3 XVM 3-11 3 400 3 x 1,1 3 x 1,5 3x3 48 2” 2”
VSD 3 XVM 3-12 3 400 3 x 1,1 3 x 1,5 3x3 52 2” 2”
VSD 3 XVM 3-13 3 400 3 x 1,1 3 x 1,5 3x3 57 2” 2”
VSD 3 XVM 3-15 3 400 3 x 1,1 3 x 1,5 3x3 68 2” 2”
VSD 3 XVM 3-17 3 400 3 x 1,5 3x2 3x3 79 2” 2”
VSD 3 XVM 3-19 3 400 3 x 1,5 3x2 3x3 88 2” 2”
VSD 3 XVM 3-21 3 400 3 x 2,2 3x3 3x3 97 2” 2”
VSD 3 XVM 3-23 3 400 3 x 2,2 3x3 3x3 105 2” 2”
VSD 3 XVM 3-25 3 400 3 x 2,2 3x3 3x3 113 2” 2”
VSD 3 XVM 3-27 3 400 3 x 2,2 3x3 3x3 123 2” 2”
VSD 3 XVM 3-29 3 400 3 x 2,2 3x3 3x3 132 2” 2”
VSD 3 XVM 3-31 3 400 3x3 3x4 3x3 141 2” 2”
VSD 3 XVM 3-33 3 400 3x3 3x4 3x3 150 2” 2”
VSD 3 XVM 3-36 3 400 3x3 3x4 3x3 166 2” 2”

907
VSD3
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 3 XVM 5-6 3 400 3 x 1,1 3 x 1,5 3 x 5,5 28 2" 2"
VSD 3 XVM 5-7 3 400 3 x 1,1 3 x 1,5 3 x 5,5 33 2" 2"
VSD 3 XVM 5-8 3 400 3 x 1,1 3 x 1,5 3 x 5,5 38 2” 2”
VSD 3 XVM 5-9 3 400 3 x 1,5 3x2 3 x 5,5 42 2” 2”
VSD 3 XVM 5-10 3 400 3 x 1,5 3x2 3 x 5,5 47 2” 2”
VSD 3 XVM 5-11 3 400 3 x 2,2 3x3 3 x 5,5 52 2” 2”
VSD 3 XVM 5-12 3 400 3 x 2,2 3x3 3 x 5,5 58 2” 2”
VSD 3 XVM 5-13 3 400 3 x 2,2 3x3 3 x 5,5 64 2” 2”
VSD 3 XVM 5-14 3 400 3 x 2,2 3x3 3 x 5,5 69 2” 2”
VSD 3 XVM 5-15 3 400 3 x 2,2 3x3 3 x 5,5 75 2” 2”
VSD 3 XVM 5-16 3 400 3 x 2,2 3x3 3 x 5,5 80 2” 2”
VSD 3 XVM 5-18 3 400 3x3 3x4 3 x 5,5 90 2” 2”
VSD 3 XVM 5-20 3 400 3x3 3x4 3 x 5,5 99 2” 2”
VSD 3 XVM 5-22 3 400 3x4 3 x 5,5 3 x 5,5 110 2” 2”
VSD 3 XVM 5-24 3 400 3x4 3 x 5,5 3 x 5,5 120 2” 2”
VSD 3 XVM 5-26 3 400 3x4 3 x 5,5 3 x 5,5 131 2” 2”
VSD 3 XVM 5-29 3 400 3x4 3 x 5,5 3 x 5,5 150 2” 2”
VSD 3 XVM 5-32 3 400 3 x 5,5 3 x 7,5 3 x 5,5 166 2” 2”
VSD 3 XVM 5-36 3 400 3 x 5,5 3 x 7,5 3 x 5,5 188 2” 2”

VSD 3 XVM 10-3 3 400 3 x 1,1 3 x 1,5 3 x 10 25 3” 3”


VSD 3 XVM 10-4 3 400 3 x 1,5 3x2 3 x 10 32 3” 3”
VSD 3 XVM 10-5 3 400 3 x 2,2 3x3 3 x 10 39 3” 3”
VSD 3 XVM 10-6 3 400 3 x 2,2 3x3 3 x 10 46 3” 3”
VSD 3 XVM 10-7 3 400 3x3 3x4 3 x 10 54 3” 3”
VSD 3 XVM 10-8 3 400 3x3 3x4 3 x 10 62 3” 3”
VSD 3 XVM 10-9 3 400 3x3 3x4 3 x 10 71 3” 3”
VSD 3 XVM 10-10 3 400 3x4 3 x 5,5 3 x 10 81 3” 3”
VSD 3 XVM 10-12 3 400 3x4 3 x 5,5 3 x 10 95 3” 3”
VSD 3 XVM 10-14 3 400 3 x 5,5 3 x 7,5 3 x 10 110 3” 3”
VSD 3 XVM 10-16 3 400 3 x 5,5 3 x 7,5 3 x 10 125 3” 3”
VSD 3 XVM 10-18 3 400 3 x 7,5 3 x 10 3 x 10 144 3” 3”
VSD 3 XVM 10-20 3 400 3 x 7,5 3 x 10 3 x 10 160 3” 3”
VSD 3 XVM 10-22 3 400 3 x 7,5 3 x 10 3 x 10 178 3” 3”

908
VSD3
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 3 XVM 15-3 3 400 3x3 3x4 3 x 16 31 DN 100 3"
VSD 3 XVM 15-4 3 400 3x4 3 x 5,5 3 x 16 43 DN 100 3”
VSD 3 XVM 15-5 3 400 3x4 3 x 5,5 3 x 16 54 DN 100 3”
VSD 3 XVM 15-6 3 400 3 x 5,5 3 x 7,5 3 x 16 65 DN 100 3”
VSD 3 XVM 15-7 3 400 3 x 5,5 3 x 7,5 3 x 16 78 DN 100 3”
VSD 3 XVM 15-8 3 400 3 x 7,5 3 x 10 3 x 16 90 DN 100 3”
VSD 3 XVM 15-9 3 400 3 x 7,5 3 x 10 3 x 16 103 DN 100 3”
VSD 3 XVM 15-10 3 400 3 x 11 3 x 15 3 x 16 116 DN 100 3”
VSD 3 XVM 15-12 3 400 3 x 11 3 x 15 3 x 16 135 DN 100 3”
VSD 3 XVM 15-14 3 400 3 x 11 3 x 15 3 x 16 156 DN 100 3”
VSD 3 XVM 15-16 3 400 3 x 15 3 x 20 3 x 16 179 DN 100 3”
VSD 3 XVM 15-17 3 400 3 x 15 3 x 20 3 x 16 193 DN 100 3”

VSD 3 XVM 20-3 3 400 3x4 3 x 5,5 3 x 20 32 DN 100 DN 100


VSD 3 XVM 20-4 3 400 3 x 5,5 3 x 7,5 3 x 20 43 DN 100 DN 100
VSD 3 XVM 20-5 3 400 3 x 5,5 3 x 7,5 3 x 20 55 DN 100 DN 100
VSD 3 XVM 20-6 3 400 3 x 7,5 3 x 10 3 x 20 66 DN 100 DN 100
VSD 3 XVM 20-7 3 400 3 x 7,5 3 x 10 3 x 20 77 DN 100 DN 100
VSD 3 XVM 20-8 3 400 3 x 11 3 x 15 3 x 20 89 DN 100 DN 100
VSD 3 XVM 20-10 3 400 3 x 11 3 x 15 3 x 20 112 DN 100 DN 100
VSD 3 XVM 20-12 3 400 3 x 15 3 x 20 3 x 20 136 DN 100 DN 100
VSD 3 XVM 20-14 3 400 3 x 15 3 x 20 3 x 20 161 DN 100 DN 100
VSD 3 XVM 20-16 3 400 3 x 18,5 3 x 25 3 x 20 186 DN 100 DN 100
VSD 3 XVM 20-17 3 400 3 x 18,5 3 x 25 3 x 20 202 DN 100 DN 100

VSD 3 XVM 32-2 3 400 3x4 3 x 5,5 3 x 30 26 DN 125 DN 125


VSD 3 XVM 32-3-2 3 400 3x4 3 x 5,5 3 x 30 34 DN 125 DN 125
VSD 3 XVM 32-3 3 400 3 x 5,5 3 x 7,5 3 x 30 39 DN 125 DN 125
VSD 3 XVM 32-4-2 3 400 3 x 7,5 3 x 10 3 x 30 47 DN 125 DN 125
VSD 3 XVM 32-4 3 400 3 x 7,5 3 x 10 3 x 30 53 DN 125 DN 125
VSD 3 XVM 32-5-2 3 400 3 x 11 3 x 15 3 x 30 61 DN 125 DN 125
VSD 3 XVM 32-5 3 400 3 x 11 3 x 15 3 x 30 66 DN 125 DN 125
VSD 3 XVM 32-6-2 3 400 3 x 11 3 x 15 3 x 30 75 DN 125 DN 125
VSD 3 XVM 32-6 3 400 3 x 11 3 x 15 3 x 30 83 DN 125 DN 125
VSD 3 XVM 32-7-2 3 400 3 x 15 3 x 20 3 x 30 90 DN 125 DN 125
VSD 3 XVM 32-7 3 400 3 x 15 3 x 20 3 x 30 97 DN 125 DN 125

909
VSD3
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 3 XVM 32-8-2 3 400 3 x 15 3 x 20 3 x 30 104 DN 125 DN 125
VSD 3 XVM 32-8 3 400 3 x 15 3 x 20 3 x 30 111 DN 125 DN 125
VSD 3 XVM 32-9-2 3 400 3 x 18,5 3 x 25 3 x 30 119 DN 125 DN 125
VSD 3 XVM 32-9 3 400 3 x 18,5 3 x 25 3 x 30 126 DN 125 DN 125
VSD 3 XVM 32-10-2 3 400 3 x 18,5 3 x 25 3 x 30 135 DN 125 DN 125
VSD 3 XVM 32-10 3 400 3 x 18,5 3 x 25 3 x 30 142 DN 125 DN 125
VSD 3 XVM 32-11-2 3 400 3 x 22 3 x 30 3 x 30 149 DN 125 DN 125
VSD 3 XVM 32-11 3 400 3 x 22 3 x 30 3 x 30 157 DN 125 DN 125
VSD 3 XVM 32-12-2 3 400 3 x 22 3 x 30 3 x 30 165 DN 125 DN 125
VSD 3 XVM 32-12 3 400 3 x 22 3 x 30 3 x 30 171 DN 125 DN 125
VSD 3 XVM 32-13-2 3 400 3 x 30 3 x 40 3 x 30 179 DN 125 DN 125
VSD 3 XVM 32-13 3 400 3 x 30 3 x 40 3 x 30 187 DN 125 DN 125
VSD 3 XVM 32-14-2 3 400 3 x 30 3 x 40 3 x 30 197 DN 125 DN 125

VSD 3 XVM 45-2-2 3 400 3 x 5,5 3 x 7,5 3 x 45 30 DN 150 DN 150


VSD 3 XVM 45-2 3 400 3 x 7,5 3 x 10 3 x 45 39 DN 150 DN 150
VSD 3 XVM 45-3-2 3 400 3 x 11 3 x 15 3 x 45 50 DN 150 DN 150
VSD 3 XVM 45-3 3 400 3 x 11 3 x 15 3 x 45 58 DN 150 DN 150
VSD 3 XVM 45-4-2 3 400 3 x 15 3 x 20 3 x 45 69 DN 150 DN 150
VSD 3 XVM 45-4 3 400 3 x 15 3 x 20 3 x 45 77 DN 150 DN 150
VSD 3 XVM 45-5-2 3 400 3 x 18,5 3 x 25 3 x 45 88 DN 150 DN 150
VSD 3 XVM 45-5 3 400 3 x 18,5 3 x 25 3 x 45 97 DN 150 DN 150
VSD 3 XVM 45-6-2 3 400 3 x 22 3 x 30 3 x 45 109 DN 150 DN 150
VSD 3 XVM 45-6 3 400 3 x 22 3 x 30 3 x 45 118 DN 150 DN 150
VSD 3 XVM 45-7-2 3 400 3 x 30 3 x 40 3 x 45 128 DN 150 DN 150
VSD 3 XVM 45-7 3 400 3 x 30 3 x 40 3 x 45 136 DN 150 DN 150
VSD 3 XVM 45-8-2 3 400 3 x 30 3 x 40 3 x 45 147 DN 150 DN 150
VSD 3 XVM 45-8 3 400 3 x 30 3 x 40 3 x 45 155 DN 150 DN 150
VSD 3 XVM 45-9-2 3 400 3 x 30 3 x 40 3 x 45 169 DN 150 DN 150
VSD 3 XVM 45-9 3 400 3 x 37 3 x 50 3 x 45 177 DN 150 DN 150
VSD 3 XVM 45-10-2 3 400 3 x 37 3 x 50 3 x 45 188 DN 150 DN 150

910
VSD3
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 3 XVM 64-2-2 3 400 3 x 7,5 3 x 10 3 x 64 26 DN 200 DN 200
VSD 3 XVM 64-2-1 3 400 3 x 11 3 x 15 3 x 64 34 DN 200 DN 200
VSD 3 XVM 64-2 3 400 3 x 11 3 x 15 3 x 64 40 DN 200 DN 200
VSD 3 XVM 64-3-2 3 400 3 x 15 3 x 20 3 x 64 46 DN 200 DN 200
VSD 3 XVM 64-3-1 3 400 3 x 15 3 x 20 3 x 64 53 DN 200 DN 200
VSD 3 XVM 64-3 3 400 3 x 18,5 3 x 25 3 x 64 60 DN 200 DN 200
VSD 3 XVM 64-4-2 3 400 3 x 18,5 3 x 25 3 x 64 66 DN 200 DN 200
VSD 3 XVM 64-4-1 3 400 3 x 22 3 x 30 3 x 64 73 DN 200 DN 200
VSD 3 XVM 64-4 3 400 3 x 22 3 x 30 3 x 64 80 DN 200 DN 200
VSD 3 XVM 64-5-2 3 400 3 x 30 3 x 40 3 x 64 89 DN 200 DN 200
VSD 3 XVM 64-5-1 3 400 3 x 30 3 x 40 3 x 64 96 DN 200 DN 200
VSD 3 XVM 64-5 3 400 3 x 30 3 x 40 3 x 64 103 DN 200 DN 200
VSD 3 XVM 64-6-2 3 400 3 x 30 3 x 40 3 x 64 112 DN 200 DN 200
VSD 3 XVM 64-6-1 3 400 3 x 37 3 x 50 3 x 64 118 DN 200 DN 200
VSD 3 XVM 64-6 3 400 3 x 37 3 x 50 3 x 64 125 DN 200 DN 200
VSD 3 XVM 64-7-2 3 400 3 x 37 3 x 50 3 x 64 133 DN 200 DN 200
VSD 3 XVM 64-7-1 3 400 3 x 37 3 x 50 3 x 64 140 DN 200 DN 200
VSD 3 XVM 64-7 3 400 3 x 45 3 x 60 3 x 64 147 DN 200 DN 200
VSD 3 XVM 64-8-2 3 400 3 x 45 3 x 60 3 x 64 155 DN 200 DN 200
VSD 3 XVM 64-8-1 3 400 3 x 45 3 x 60 3 x 64 162 DN 200 DN 200

VSD 3 XVM 90-2-2 3 400 3 x 11 3 x 15 3 x 85 30 DN 200 DN 200


VSD 3 XVM 90-2 3 400 3 x 15 3 x 20 3 x 85 43 DN 200 DN 200
VSD 3 XVM 90-3-2 3 400 3 x 18,5 3 x 25 3 x 85 52 DN 200 DN 200
VSD 3 XVM 90-3 3 400 3 x 22 3 x 30 3 x 85 64 DN 200 DN 200
VSD 3 XVM 90-4-2 3 400 3 x 30 3 x 40 3 x 85 76 DN 200 DN 200
VSD 3 XVM 90-4 3 400 3 x 30 3 x 40 3 x 85 88 DN 200 DN 200
VSD 3 XVM 90-5-2 3 400 3 x 37 3 x 50 3 x 85 100 DN 200 DN 200
VSD 3 XVM 90-5 3 400 3 x 37 3 x 50 3 x 85 113 DN 200 DN 200
VSD 3 XVM 90-6-2 3 400 3 x 45 3 x 60 3 x 85 124 DN 200 DN 200
VSD 3 XVM 90-6 3 400 3 x 45 3 x 60 3 x 85 135 DN 200 DN 200

911
VSD3
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD3 WTM 32-160/3 3 400 3x3 3x4 3 x 18 25 DN 100 DN 100
VSD3 WTM 32-200/3 3 400 3x3 3x4 3 x 19 30 DN 100 DN 100
VSD3 WTM 32-200/4 3 400 3x4 3 x 5,5 3 x 19 40 DN 100 DN 100
VSD3 WTM 32-250/5,5 3 400 3 x 5,5 3 x 7,5 3 x 18 55 DN 100 DN 100
VSD3 WTM 32-250/7,5 3 400 3 x 7,5 3 x 10 3 x 20 70 DN 100 DN 100
VSD3 WTM 40-160/3 3 400 3x3 3x4 3 x 28 25 DN 150 DN 150
VSD3 WTM 40-160/4 3 400 3x4 3 x 5,5 3 x 32 30 DN 150 DN 150
VSD3 WTM 40-200/5,5 3 400 3 x 5,5 3 x 7,5 3 x 32 35 DN 150 DN 150
VSD3 WTM 40-200/7,5 3 400 3 x 7,5 3 x 10 3 x 32 45 DN 150 DN 150
VSD3 WTM 40-250/9,2 3 400 3 x 9,2 3 x 12,5 3 x 35 50 DN 150 DN 150
VSD3 WTM 40-250/11 3 400 3 x 11 3 x 15 3 x 35 55 DN 150 DN 150
VSD3 WTM 40-250/15 3 400 3 x 15 3 x 20 3 x 40 65 DN 150 DN 150
VSD3 WTM 50-160/5,5 3 400 3 x 5,5 3 x 7,5 3 x 60 25 DN 200 DN 200
VSD3 WTM 50-160/7,5 3 400 3 x 7,5 3 x 10 3 x 65 30 DN 200 DN 200
VSD3 WTM 50-200/9,2 3 400 3 x 9,2 3 x 12,5 3 x 60 38 DN 200 DN 200
VSD3 WTM 50-200/11 3 400 3 x 11 3 x 15 3 x 60 45 DN 200 DN 200
VSD3 WTM 50-250/15 3 400 3 x 15 3 x 20 3 x 60 55 DN 200 DN 200
VSD3 WTM 50-250/18,5 3 400 3 x 18,5 3 x 25 3 x 70 60 DN 200 DN 200
VSD3 WTM 50-250/22 3 400 3 x 22 3 x 30 3 x 70 70 DN 200 DN 200
VSD3 WTM 65-125/7,5 3 400 3 x 7,5 3 x 10 3 x 90 22 DN 250 DN 200
VSD3 WTM 65-160/9,2 3 400 3 x 9,2 3 x 12,5 3 x 95 25 DN 250 DN 200
VSD3 WTM 65-160/11 3 400 3 x 11 3 x 15 3 x 95 30 DN 250 DN 200
VSD3 WTM 65-160/15 3 400 3 x 15 3 x 20 3 x 105 35 DN 250 DN 200
VSD3 WTM 65-200/15 3 400 3 x 15 3 x 20 3 x 85 40 DN 250 DN 200
VSD3 WTM 65-200/18,5 3 400 3 x 18,5 3 x 25 3 x 85 47 DN 250 DN 200
VSD3 WTM 65-200/22 3 400 3 x 22 3 x 30 3 x 85 54 DN 250 DN 200
VSD3 WTM 65-250/22 3 400 3 x 22 3 x 30 3 x 100 50 DN 250 DN 200
VSD3 WTM 65-250/30 3 400 3 x 30 3 x 40 3 x 110 63 DN 250 DN 200
VSD3 WTM 65-250/37 3 400 3 x 37 3 x 50 3 x 110 77 DN 250 DN 200
VSD3 WTM 80-160/11 3 400 3 x 11 3 x 15 3 x 140 22 DN 350 DN 300
VSD3 WTM 80-160/15 3 400 3 x 15 3 x 20 3 x 140 27 DN 350 DN 300
VSD3 WTM 80-160/18,5 3 400 3 x 18,5 3 x 25 3 x 150 32 DN 350 DN 300
VSD3 WTM 80-200/22 3 400 3 x 22 3 x 30 3 x 160 36 DN 350 DN 300
VSD3 WTM 80-200/30 3 400 3 x 30 3 x 40 3 x 160 50 DN 350 DN 300
VSD3 WTM 80-250/37 3 400 3 x 37 3 x 50 3 x 150 58 DN 350 DN 300
VSD3 WTM 80-250/45 3 400 3 x 45 3 x 60 3 x 150 70 DN 350 DN 300
VSD3 WTM 80-250/55 3 400 3 x 55 3 x 75 3 x 165 80 DN 350 DN 300

912
VSD4
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 4 XVM 1-7 3 400 4 x 0,37 4 x 0,55 4 x 1,6 33 2" 2"
VSD 4 XVM 1-8 3 400 4 x 0,55 4 x 0,75 4 x 1,6 38 2” 2”
VSD 4 XVM 1-9 3 400 4 x 0,55 4 x 0,75 4 x 1,6 44 2” 2”
VSD 4 XVM 1-10 3 400 4 x 0,55 4 x 0,75 4 x 1,6 48 2” 2”
VSD 4 XVM 1-11 3 400 4 x 0,55 4 x 0,75 4 x 1,6 54 2” 2”
VSD 4 XVM 1-12 3 400 4 x 0,75 4x1 4 x 1,6 58 2” 2”
VSD 4 XVM 1-13 3 400 4 x 0,75 4x1 4 x 1,6 63 2” 2”
VSD 4 XVM 1-15 3 400 4 x 0,75 4x1 4 x 1,6 72 2” 2”
VSD 4 XVM 1-17 3 400 4 x 1,1 4 x 1,5 4 x 1,6 81 2” 2”
VSD 4 XVM 1-19 3 400 4 x 1,1 4 x 1,5 4 x 1,6 91 2” 2”
VSD 4 XVM 1-21 3 400 4 x 1,1 4 x 1,5 4 x 1,6 101 2” 2”
VSD 4 XVM 1-23 3 400 4 x 1,1 4 x 1,5 4 x 1,6 111 2” 2”
VSD 4 XVM 1-25 3 400 4 x 1,5 4x2 4 x 1,6 121 2” 2”
VSD 4 XVM 1-27 3 400 4 x 1,5 4x2 4 x 1,6 130 2” 2”
VSD 4 XVM 1-30 3 400 4 x 1,5 4x2 4 x 1,6 145 2” 2”
VSD 4 XVM 1-33 3 400 4 x 2,2 4x3 4 x 1,6 160 2” 2”
VSD 4 XVM 1-36 3 400 4 x 2,2 4x3 4 x 1,6 174 2” 2”

VSD 4 XVM 3-6 3 400 4 x 0,55 4 x 0,75 4x3 26 2” 2”


VSD 4 XVM 3-7 3 400 4 x 0,55 4 x 0,75 4x3 30 2” 2”
VSD 4 XVM 3-8 3 400 4 x 0,75 4x1 4x3 35 2” 2”
VSD 4 XVM 3-9 3 400 4 x 0,75 4x1 4x3 39 2” 2”
VSD 4 XVM 3-10 3 400 4 x 0,75 4x1 4x3 43 2” 2”
VSD 4 XVM 3-11 3 400 4 x 1,1 4 x 1,5 4x3 48 2” 2”
VSD 4 XVM 3-12 3 400 4 x 1,1 4 x 1,5 4x3 52 2” 2”
VSD 4 XVM 3-13 3 400 4 x 1,1 4 x 1,5 4x3 57 2” 2”
VSD 4 XVM 3-15 3 400 4 x 1,1 4 x 1,5 4x3 68 2” 2”
VSD 4 XVM 3-17 3 400 4 x 1,5 4x2 4x3 79 2” 2”
VSD 4 XVM 3-19 3 400 4 x 1,5 4x2 4x3 88 2” 2”
VSD 4 XVM 3-21 3 400 4 x 2,2 4x3 4x3 97 2” 2”
VSD 4 XVM 3-23 3 400 4 x 2,2 4x3 4x3 105 2” 2”
VSD 4 XVM 3-25 3 400 4 x 2,2 4x3 4x3 113 2” 2”
VSD 4 XVM 3-27 3 400 4 x 2,2 4x3 4x3 123 2” 2”
VSD 4 XVM 3-29 3 400 4 x 2,2 4x3 4x3 132 2” 2”
VSD 4 XVM 3-31 3 400 4x3 4x4 4x3 141 2” 2”
VSD 4 XVM 3-33 3 400 4x3 4x4 4x3 150 2” 2”
VSD 4 XVM 3-36 3 400 4x3 4x4 4x3 166 2” 2”

913
VSD4
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 4 XVM 5-6 3 400 4 x 1,1 4 x 1,5 4 x 5,5 28 2½” 2½”
VSD 4 XVM 5-7 3 400 4 x 1,1 4 x 1,5 4 x 5,5 33 2½” 2½”
VSD 4 XVM 5-8 3 400 4 x 1,1 4 x 1,5 4 x 5,5 38 2½” 2½”
VSD 4 XVM 5-9 3 400 4 x 1,5 4x2 4 x 5,5 42 2½” 2½”
VSD 4 XVM 5-10 3 400 4 x 1,5 4x2 4 x 5,5 47 2½” 2½”
VSD 4 XVM 5-11 3 400 4 x 2,2 4x3 4 x 5,5 52 2½” 2½”
VSD 4 XVM 5-12 3 400 4 x 2,2 4x3 4 x 5,5 58 2½” 2½”
VSD 4 XVM 5-13 3 400 4 x 2,2 4x3 4 x 5,5 64 2½” 2½”
VSD 4 XVM 5-14 3 400 4 x 2,2 4x3 4 x 5,5 69 2½” 2½”
VSD 4 XVM 5-15 3 400 4 x 2,2 4x3 4 x 5,5 75 2½” 2½”
VSD 4 XVM 5-16 3 400 4 x 2,2 4x3 4 x 5,5 80 2½” 2½”
VSD 4 XVM 5-18 3 400 4x3 4x4 4 x 5,5 90 2½” 2½”
VSD 4 XVM 5-20 3 400 4x3 4x4 4 x 5,5 99 2½” 2½”
VSD 4 XVM 5-22 3 400 4x4 4 x 5,5 4 x 5,5 110 2½” 2½”
VSD 4 XVM 5-24 3 400 4x4 4 x 5,5 4 x 5,5 120 2½” 2½”
VSD 4 XVM 5-26 3 400 4x4 4 x 5,5 4 x 5,5 131 2½” 2½”
VSD 4 XVM 5-29 3 400 4x4 4 x 5,5 4 x 5,5 150 2½” 2½”
VSD 4 XVM 5-32 3 400 4 x 5,5 4 x 7,5 4 x 5,5 166 2½” 2½”
VSD 4 XVM 5-36 3 400 4 x 5,5 4 x 7,5 4 x 5,5 188 2½” 2½”

VSD 4 XVM 10-3 3 400 4 x 1,1 4 x 1,5 4 x 10 25 3” 3”


VSD 4 XVM 10-4 3 400 4 x 1,5 4x2 4 x 10 32 3” 3”
VSD 4 XVM 10-5 3 400 4 x 2,2 4x3 4 x 10 39 3” 3”
VSD 4 XVM 10-6 3 400 4 x 2,2 4x3 4 x 10 46 3” 3”
VSD 4 XVM 10-7 3 400 4x3 4x4 4 x 10 54 3” 3”
VSD 4 XVM 10-8 3 400 4x3 4x4 4 x 10 62 3” 3”
VSD 4 XVM 10-9 3 400 4x3 4x4 4 x 10 71 3” 3”
VSD 4 XVM 10-10 3 400 4x4 4 x 5,5 4 x 10 81 3” 3”
VSD 4 XVM 10-12 3 400 4x4 4 x 5,5 4 x 10 95 3” 3”
VSD 4 XVM 10-14 3 400 4 x 5,5 4 x 7,5 4 x 10 110 3” 3”
VSD 4 XVM 10-16 3 400 4 x 5,5 4 x 7,5 4 x 10 125 3” 3”
VSD 4 XVM 10-18 3 400 4 x 7,5 4 x 10 4 x 10 144 3” 3”
VSD 4 XVM 10-20 3 400 4 x 7,5 4 x 10 4 x 10 160 3” 3”
VSD 4 XVM 10-22 3 400 4 x 7,5 4 x 10 4 x 10 178 3” 3”

914
VSD4
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 4 XVM 15-3 3 400 4x3 4x4 4 x 16 31 DN 100 DN 100
VSD 4 XVM 15-4 3 400 4x4 4 x 5,5 4 x 16 43 DN 100 DN 100
VSD 4 XVM 15-5 3 400 4x4 4 x 5,5 4 x 16 54 DN 100 DN 100
VSD 4 XVM 15-6 3 400 4 x 5,5 4 x 7,5 4 x 16 65 DN 100 DN 100
VSD 4 XVM 15-7 3 400 4 x 5,5 4 x 7,5 4 x 16 78 DN 100 DN 100
VSD 4 XVM 15-8 3 400 4 x 7,5 4 x 10 4 x 16 90 DN 100 DN 100
VSD 4 XVM 15-9 3 400 4 x 7,5 4 x 10 4 x 16 103 DN 100 DN 100
VSD 4 XVM 15-10 3 400 4 x 11 4 x 15 4 x 16 116 DN 100 DN 100
VSD 4 XVM 15-12 3 400 4 x 11 4 x 15 4 x 16 135 DN 100 DN 100
VSD 4 XVM 15-14 3 400 4 x 11 4 x 15 4 x 16 156 DN 100 DN 100
VSD 4 XVM 15-16 3 400 4 x 15 4 x 20 4 x 16 179 DN 100 DN 100
VSD 4 XVM 15-17 3 400 4 x 15 4 x 20 4 x 16 193 DN 100 DN 100

VSD 4 XVM 20-3 3 400 4x4 4 x 5,5 4 x 20 32 DN 125 DN 100


VSD 4 XVM 20-4 3 400 4 x 5,5 4 x 7,5 4 x 20 43 DN 125 DN 100
VSD 4 XVM 20-5 3 400 4 x 5,5 4 x 7,5 4 x 20 55 DN 125 DN 100
VSD 4 XVM 20-6 3 400 4 x 7,5 4 x 10 4 x 20 66 DN 125 DN 100
VSD 4 XVM 20-7 3 400 4 x 7,5 4 x 10 4 x 20 77 DN 125 DN 100
VSD 4 XVM 20-8 3 400 4 x 11 4 x 15 4 x 20 89 DN 125 DN 100
VSD 4 XVM 20-10 3 400 4 x 11 4 x 15 4 x 20 112 DN 125 DN 100
VSD 4 XVM 20-12 3 400 4 x 15 4 x 20 4 x 20 136 DN 125 DN 100
VSD 4 XVM 20-14 3 400 4 x 15 4 x 20 4 x 20 161 DN 125 DN 100
VSD 4 XVM 20-16 3 400 4 x 18,5 4 x 25 4 x 20 186 DN 125 DN 100
VSD 4 XVM 20-17 3 400 4 x 18,5 4 x 25 4 x 20 202 DN 125 DN 100

VSD 4 XVM 32-2 3 400 4x4 4 x 5,5 4 x 30 26 DN 150 DN 150


VSD 4 XVM 32-3-2 3 400 4x4 4 x 5,5 4 x 30 34 DN 150 DN 150
VSD 4 XVM 32-3 3 400 4 x 5,5 4 x 7,5 4 x 30 39 DN 150 DN 150
VSD 4 XVM 32-4-2 3 400 4 x 7,5 4 x 10 4 x 30 47 DN 150 DN 150
VSD 4 XVM 32-4 3 400 4 x 7,5 4 x 10 4 x 30 53 DN 150 DN 150
VSD 4 XVM 32-5-2 3 400 4 x 11 4 x 15 4 x 30 61 DN 150 DN 150
VSD 4 XVM 32-5 3 400 4 x 11 4 x 15 4 x 30 66 DN 150 DN 150
VSD 4 XVM 32-6-2 3 400 4 x 11 4 x 15 4 x 30 75 DN 150 DN 150
VSD 4 XVM 32-6 3 400 4 x 11 4 x 15 4 x 30 83 DN 150 DN 150
VSD 4 XVM 32-7-2 3 400 4 x 15 4 x 20 4 x 30 90 DN 150 DN 150
VSD 4 XVM 32-7 3 400 4 x 15 4 x 20 4 x 30 97 DN 150 DN 150

915
VSD4
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 4 XVM 32-8-2 3 400 4 x 15 4 x 20 4 x 30 104 DN 150 DN 150
VSD 4 XVM 32-8 3 400 4 x 15 4 x 20 4 x 30 111 DN 150 DN 150
VSD 4 XVM 32-9-2 3 400 4 x 18,5 4 x 25 4 x 30 119 DN 150 DN 150
VSD 4 XVM 32-9 3 400 4 x 18,5 4 x 25 4 x 30 126 DN 150 DN 150
VSD 4 XVM 32-10-2 3 400 4 x 18,5 4 x 25 4 x 30 135 DN 150 DN 150
VSD 4 XVM 32-10 3 400 4 x 18,5 4 x 25 4 x 30 142 DN 150 DN 150
VSD 4 XVM 32-11-2 3 400 4 x 22 4 x 30 4 x 30 149 DN 150 DN 150
VSD 4 XVM 32-11 3 400 4 x 22 4 x 30 4 x 30 157 DN 150 DN 150
VSD 4 XVM 32-12-2 3 400 4 x 22 4 x 30 4 x 30 165 DN 150 DN 150
VSD 4 XVM 32-12 3 400 4 x 22 4 x 30 4 x 30 171 DN 150 DN 150
VSD 4 XVM 32-13-2 3 400 4 x 30 4 x 40 4 x 30 179 DN 150 DN 150
VSD 4 XVM 32-13 3 400 4 x 30 4 x 40 4 x 30 187 DN 150 DN 150
VSD 4 XVM 32-14-2 3 400 4 x 30 4 x 40 4 x 30 197 DN 150 DN 150

VSD 4 XVM 45-2-2 3 400 4 x 5,5 4 x 7,5 4 x 45 30 DN 200 DN 150


VSD 4 XVM 45-2 3 400 4 x 7,5 4 x 10 4 x 45 39 DN 200 DN 150
VSD 4 XVM 45-3-2 3 400 4 x 11 4 x 15 4 x 45 50 DN 200 DN 150
VSD 4 XVM 45-3 3 400 4 x 11 4 x 15 4 x 45 58 DN 200 DN 150
VSD 4 XVM 45-4-2 3 400 4 x 15 4 x 20 4 x 45 69 DN 200 DN 150
VSD 4 XVM 45-4 3 400 4 x 15 4 x 20 4 x 45 77 DN 200 DN 150
VSD 4 XVM 45-5-2 3 400 4 x 18,5 4 x 25 4 x 45 88 DN 200 DN 150
VSD 4 XVM 45-5 3 400 4 x 18,5 4 x 25 4 x 45 97 DN 200 DN 150
VSD 4 XVM 45-6-2 3 400 4 x 22 4 x 30 4 x 45 109 DN 200 DN 150
VSD 4 XVM 45-6 3 400 4 x 22 4 x 30 4 x 45 118 DN 200 DN 150
VSD 4 XVM 45-7-2 3 400 4 x 30 4 x 40 4 x 45 128 DN 200 DN 150
VSD 4 XVM 45-7 3 400 4 x 30 4 x 40 4 x 45 136 DN 200 DN 150
VSD 4 XVM 45-8-2 3 400 4 x 30 4 x 40 4 x 45 147 DN 200 DN 150
VSD 4 XVM 45-8 3 400 4 x 30 4 x 40 4 x 45 155 DN 200 DN 150
VSD 4 XVM 45-9-2 3 400 4 x 30 4 x 40 4 x 45 169 DN 200 DN 150
VSD 4 XVM 45-9 3 400 4 x 37 4 x 50 4 x 45 177 DN 200 DN 150
VSD 4 XVM 45-10-2 3 400 4 x 37 4 x 50 4 x 45 188 DN 200 DN 150

916
VSD4
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 4 XVM 64-2-2 3 400 4 x 7,5 4 x 10 4 x 64 26 DN 250 DN 200
VSD 4 XVM 64-2-1 3 400 4 x 11 4 x 15 4 x 64 34 DN 250 DN 200
VSD 4 XVM 64-2 3 400 4 x 11 4 x 15 4 x 64 40 DN 250 DN 200
VSD 4 XVM 64-3-2 3 400 4 x 15 4 x 20 4 x 64 46 DN 250 DN 200
VSD 4 XVM 64-3-1 3 400 4 x 15 4 x 20 4 x 64 53 DN 250 DN 200
VSD 4 XVM 64-3 3 400 4 x 18,5 4 x 25 4 x 64 60 DN 250 DN 200
VSD 4 XVM 64-4-2 3 400 4 x 18,5 4 x 25 4 x 64 66 DN 250 DN 200
VSD 4 XVM 64-4-1 3 400 4 x 22 4 x 30 4 x 64 73 DN 250 DN 200
VSD 4 XVM 64-4 3 400 4 x 22 4 x 30 4 x 64 80 DN 250 DN 200
VSD 4 XVM 64-5-2 3 400 4 x 30 4 x 40 4 x 64 89 DN 250 DN 200
VSD 4 XVM 64-5-1 3 400 4 x 30 4 x 40 4 x 64 96 DN 250 DN 200
VSD 4 XVM 64-5 3 400 4 x 30 4 x 40 4 x 64 103 DN 250 DN 200
VSD 4 XVM 64-6-2 3 400 4 x 30 4 x 40 4 x 64 112 DN 250 DN 200
VSD 4 XVM 64-6-1 3 400 4 x 37 4 x 50 4 x 64 118 DN 250 DN 200
VSD 4 XVM 64-6 3 400 4 x 37 4 x 50 4 x 64 125 DN 250 DN 200
VSD 4 XVM 64-7-2 3 400 4 x 37 4 x 50 4 x 64 133 DN 250 DN 200
VSD 4 XVM 64-7-1 3 400 4 x 37 4 x 50 4 x 64 140 DN 250 DN 200
VSD 4 XVM 64-7 3 400 4 x 45 4 x 60 4 x 64 147 DN 250 DN 200
VSD 4 XVM 64-8-2 3 400 4 x 45 4 x 60 4 x 64 155 DN 250 DN 200
VSD 4 XVM 64-8-1 3 400 4 x 45 4 x 60 4 x 64 162 DN 250 DN 200

VSD 4 XVM 90-2-2 3 400 5 x11 5 x15 5 x85 30 DN 250 DN 250


VSD 4 XVM 90-2 3 400 5 x15 5 x20 5 x85 43 DN 250 DN 250
VSD 4 XVM 90-3-2 3 400 5 x18,5 5 x25 5 x85 52 DN 250 DN 250
VSD 4 XVM 90-3 3 400 5 x22 5 x30 5 x85 64 DN 250 DN 250
VSD 4 XVM 90-4-2 3 400 5 x30 5 x40 5 x85 76 DN 250 DN 250
VSD 4 XVM 90-4 3 400 5 x30 5 x40 5 x85 88 DN 250 DN 250
VSD 4 XVM 90-5-2 3 400 5 x37 5 x50 5 x85 100 DN 250 DN 250
VSD 4 XVM 90-5 3 400 5 x37 5 x50 5 x85 113 DN 250 DN 250
VSD 4 XVM 90-6-2 3 400 5 x45 5 x60 5 x85 124 DN 250 DN 250
VSD 4 XVM 90-6 3 400 5 x45 5 x60 5 x85 135 DN 250 DN 250

917
VSD5
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 5 XVM 1-7 3 400 5 x0,37 5 x0,55 5 x1,6 33 2" 2"
VSD 5 XVM 1-8 3 400 5 x0,55 5 x0,75 5 x1,6 38 2” 2”
VSD 5 XVM 1-9 3 400 5 x0,55 5 x0,75 5 x1,6 44 2” 2”
VSD 5 XVM 1-10 3 400 5 x0,55 5 x0,75 5 x1,6 48 2” 2”
VSD 5 XVM 1-11 3 400 5 x0,55 5 x0,75 5 x1,6 54 2” 2”
VSD 5 XVM 1-12 3 400 5 x0,75 5 x1 5 x1,6 58 2” 2”
VSD 5 XVM 1-13 3 400 5 x0,75 5 x1 5 x1,6 63 2” 2”
VSD 5 XVM 1-15 3 400 5 x0,75 5 x1 5 x1,6 72 2” 2”
VSD 5 XVM 1-17 3 400 5 x1,1 5 x1,5 5 x1,6 81 2” 2”
VSD 5 XVM 1-19 3 400 5 x1,1 5 x1,5 5 x1,6 91 2” 2”
VSD 5 XVM 1-21 3 400 5 x1,1 5 x1,5 5 x1,6 101 2” 2”
VSD 5 XVM 1-23 3 400 5 x1,1 5 x1,5 5 x1,6 111 2” 2”
VSD 5 XVM 1-25 3 400 5 x1,5 5 x2 5 x1,6 121 2” 2”
VSD 5 XVM 1-27 3 400 5 x1,5 5 x2 5 x1,6 130 2” 2”
VSD 5 XVM 1-30 3 400 5 x1,5 5 x2 5 x1,6 145 2” 2”
VSD 5 XVM 1-33 3 400 5 x2,2 5 x3 5 x1,6 160 2” 2”
VSD 5 XVM 1-36 3 400 5 x2,2 5 x3 5 x1,6 174 2” 2”

VSD 5 XVM 3-6 3 400 5 x0,55 5 x0,75 5 x3 26 2½” 2”


VSD 5 XVM 3-7 3 400 5 x0,55 5 x0,75 5 x3 30 2½” 2”
VSD 5 XVM 3-8 3 400 5 x0,75 5 x1 5 x3 35 2½” 2”
VSD 5 XVM 3-9 3 400 5 x0,75 5 x1 5 x3 39 2½” 2”
VSD 5 XVM 3-10 3 400 5 x0,75 5 x1 5 x3 43 2½” 2”
VSD 5 XVM 3-11 3 400 5 x1,1 5 x1,5 5 x3 48 2½” 2”
VSD 5 XVM 3-12 3 400 5 x1,1 5 x1,5 5 x3 52 2½” 2”
VSD 5 XVM 3-13 3 400 5 x1,1 5 x1,5 5 x3 57 2½” 2”
VSD 5 XVM 3-15 3 400 5 x1,1 5 x1,5 5 x3 68 2½” 2”
VSD 5 XVM 3-17 3 400 5 x1,5 5 x2 5 x3 79 2½” 2”
VSD 5 XVM 3-19 3 400 5 x1,5 5 x2 5 x3 88 2½” 2”
VSD 5 XVM 3-21 3 400 5 x2,2 5 x3 5 x3 97 2½” 2”
VSD 5 XVM 3-23 3 400 5 x2,2 5 x3 5 x3 105 2½” 2”
VSD 5 XVM 3-25 3 400 5 x2,2 5 x3 5 x3 113 2½” 2”
VSD 5 XVM 3-27 3 400 5 x2,2 5 x3 5 x3 123 2½” 2”
VSD 5 XVM 3-29 3 400 5 x2,2 5 x3 5 x3 132 2½” 2”
VSD 5 XVM 3-31 3 400 5 x3 5 x4 5 x3 141 2½” 2”
VSD 5 XVM 3-33 3 400 5 x3 5 x4 5 x3 150 2½” 2”
VSD 5 XVM 3-36 3 400 5 x3 5 x4 5 x3 166 2½” 2”

918
VSD5
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 5 XVM 5-6 3 400 5 x1,1 5 x1,5 5 x5,5 28 3” 2½”
VSD 5 XVM 5-7 3 400 5 x1,1 5 x1,5 5 x5,5 33 3” 2½”
VSD 5 XVM 5-8 3 400 5 x1,1 5 x1,5 5 x5,5 38 3” 2½”
VSD 5 XVM 5-9 3 400 5 x1,5 5 x2 5 x5,5 42 3” 2½”
VSD 5 XVM 5-10 3 400 5 x1,5 5 x2 5 x5,5 47 3” 2½”
VSD 5 XVM 5-11 3 400 5 x2,2 5 x3 5 x5,5 52 3” 2½”
VSD 5 XVM 5-12 3 400 5 x2,2 5 x3 5 x5,5 58 3” 2½”
VSD 5 XVM 5-13 3 400 5 x2,2 5 x3 5 x5,5 64 3” 2½”
VSD 5 XVM 5-14 3 400 5 x2,2 5 x3 5 x5,5 69 3” 2½”
VSD 5 XVM 5-15 3 400 5 x2,2 5 x3 5 x5,5 75 3” 2½”
VSD 5 XVM 5-16 3 400 5 x2,2 5 x3 5 x5,5 80 3” 2½”
VSD 5 XVM 5-18 3 400 5 x3 5 x4 5 x5,5 90 3” 2½”
VSD 5 XVM 5-20 3 400 5 x3 5 x4 5 x5,5 99 3” 2½”
VSD 5 XVM 5-22 3 400 5 x4 5 x5,5 5 x5,5 110 3” 2½”
VSD 5 XVM 5-24 3 400 5 x4 5 x5,5 5 x5,5 120 3” 2½”
VSD 5 XVM 5-26 3 400 5 x4 5 x5,5 5 x5,5 131 3” 2½”
VSD 5 XVM 5-29 3 400 5 x4 5 x5,5 5 x5,5 150 3” 2½”
VSD 5 XVM 5-32 3 400 5 x5,5 5 x7,5 5 x5,5 166 3” 2½”
VSD 5 XVM 5-36 3 400 5 x5,5 5 x7,5 5 x5,5 188 3” 2½”

VSD 5 XVM 10-3 3 400 5 x1,1 5 x1,5 5 x10 25 DN 100 DN 100


VSD 5 XVM 10-4 3 400 5 x1,5 5 x2 5 x10 32 DN 100 DN 100
VSD 5 XVM 10-5 3 400 5 x2,2 5 x3 5 x10 39 DN 100 DN 100
VSD 5 XVM 10-6 3 400 5 x2,2 5 x3 5 x10 46 DN 100 DN 100
VSD 5 XVM 10-7 3 400 5 x3 5 x4 5 x10 54 DN 100 DN 100
VSD 5 XVM 10-8 3 400 5 x3 5 x4 5 x10 62 DN 100 DN 100
VSD 5 XVM 10-9 3 400 5 x3 5 x4 5 x10 71 DN 100 DN 100
VSD 5 XVM 10-10 3 400 5 x4 5 x5,5 5 x10 81 DN 100 DN 100
VSD 5 XVM 10-12 3 400 5 x4 5 x5,5 5 x10 95 DN 100 DN 100
VSD 5 XVM 10-14 3 400 5 x5,5 5 x7,5 5 x10 110 DN 100 DN 100
VSD 5 XVM 10-16 3 400 5 x5,5 5 x7,5 5 x10 125 DN 100 DN 100
VSD 5 XVM 10-18 3 400 5 x7,5 5 x10 5 x10 144 DN 100 DN 100
VSD 5 XVM 10-20 3 400 5 x7,5 5 x10 5 x10 160 DN 100 DN 100
VSD 5 XVM 10-22 3 400 5 x7,5 5 x10 5 x10 178 DN 100 DN 100

919
VSD5
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 5 XVM 15-3 3 400 5 x3 5 x4 5 x16 31 DN 125 DN 125
VSD 5 XVM 15-4 3 400 5 x4 5 x5,5 5 x16 43 DN 125 DN 125
VSD 5 XVM 15-5 3 400 5 x4 5 x5,5 5 x16 54 DN 125 DN 125
VSD 5 XVM 15-6 3 400 5 x5,5 5 x7,5 5 x16 65 DN 125 DN 125
VSD 5 XVM 15-7 3 400 5 x5,5 5 x7,5 5 x16 78 DN 125 DN 125
VSD 5 XVM 15-8 3 400 5 x7,5 5 x10 5 x16 90 DN 125 DN 125
VSD 5 XVM 15-9 3 400 5 x7,5 5 x10 5 x16 103 DN 125 DN 125
VSD 5 XVM 15-10 3 400 5 x11 5 x15 5 x16 116 DN 125 DN 125
VSD 5 XVM 15-12 3 400 5 x11 5 x15 5 x16 135 DN 125 DN 125
VSD 5 XVM 15-14 3 400 5 x11 5 x15 5 x16 156 DN 125 DN 125
VSD 5 XVM 15-16 3 400 5 x15 5 x20 5 x16 179 DN 125 DN 125
VSD 5 XVM 15-17 3 400 5 x15 5 x20 5 x16 193 DN 125 DN 125

VSD 5 XVM 20-3 3 400 5 x4 5 x5,5 5 x20 32 DN 125 DN 125


VSD 5 XVM 20-4 3 400 5 x5,5 5 x7,5 5 x20 43 DN 125 DN 125
VSD 5 XVM 20-5 3 400 5 x5,5 5 x7,5 5 x20 55 DN 125 DN 125
VSD 5 XVM 20-6 3 400 5 x7,5 5 x10 5 x20 66 DN 125 DN 125
VSD 5 XVM 20-7 3 400 5 x7,5 5 x10 5 x20 77 DN 125 DN 125
VSD 5 XVM 20-8 3 400 5 x11 5 x15 5 x20 89 DN 125 DN 125
VSD 5 XVM 20-10 3 400 5 x11 5 x15 5 x20 112 DN 125 DN 125
VSD 5 XVM 20-12 3 400 5 x15 5 x20 5 x20 136 DN 125 DN 125
VSD 5 XVM 20-14 3 400 5 x15 5 x20 5 x20 161 DN 125 DN 125
VSD 5 XVM 20-16 3 400 5 x18,5 5 x25 5 x20 186 DN 125 DN 125
VSD 5 XVM 20-17 3 400 5 x18,5 5 x25 5 x20 202 DN 125 DN 125

VSD 5 XVM 32-2 3 400 5 x4 5 x5,5 5 x30 26 DN 200 DN 150


VSD 5 XVM 32-3-2 3 400 5 x4 5 x5,5 5 x30 34 DN 200 DN 150
VSD 5 XVM 32-3 3 400 5 x5,5 5 x7,5 5 x30 39 DN 200 DN 150
VSD 5 XVM 32-4-2 3 400 5 x7,5 5 x10 5 x30 47 DN 200 DN 150
VSD 5 XVM 32-4 3 400 5 x7,5 5 x10 5 x30 53 DN 200 DN 150
VSD 5 XVM 32-5-2 3 400 5 x11 5 x15 5 x30 61 DN 200 DN 150
VSD 5 XVM 32-5 3 400 5 x11 5 x15 5 x30 66 DN 200 DN 150
VSD 5 XVM 32-6-2 3 400 5 x11 5 x15 5 x30 75 DN 200 DN 150
VSD 5 XVM 32-6 3 400 5 x11 5 x15 5 x30 83 DN 200 DN 150
VSD 5 XVM 32-7-2 3 400 5 x15 5 x20 5 x30 90 DN 200 DN 150
VSD 5 XVM 32-7 3 400 5 x15 5 x20 5 x30 97 DN 200 DN 150

920
VSD5
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 5 XVM 32-8-2 3 400 5 x15 5 x20 5 x30 104 DN 200 DN 150
VSD 5 XVM 32-8 3 400 5 x15 5 x20 5 x30 111 DN 200 DN 150
VSD 5 XVM 32-9-2 3 400 5 x18,5 5 x25 5 x30 119 DN 200 DN 150
VSD 5 XVM 32-9 3 400 5 x18,5 5 x25 5 x30 126 DN 200 DN 150
VSD 5 XVM 32-10-2 3 400 5 x18,5 5 x25 5 x30 135 DN 200 DN 150
VSD 5 XVM 32-10 3 400 5 x18,5 5 x25 5 x30 142 DN 200 DN 150
VSD 5 XVM 32-11-2 3 400 5 x22 5 x30 5 x30 149 DN 200 DN 150
VSD 5 XVM 32-11 3 400 5 x22 5 x30 5 x30 157 DN 200 DN 150
VSD 5 XVM 32-12-2 3 400 5 x22 5 x30 5 x30 165 DN 200 DN 150
VSD 5 XVM 32-12 3 400 5 x22 5 x30 5 x30 171 DN 200 DN 150
VSD 5 XVM 32-13-2 3 400 5 x30 5 x40 5 x30 179 DN 200 DN 150
VSD 5 XVM 32-13 3 400 5 x30 5 x40 5 x30 187 DN 200 DN 150
VSD 5 XVM 32-14-2 3 400 5 x30 5 x40 5 x30 197 DN 200 DN 150

VSD 5 XVM 45-2-2 3 400 5 x5,5 5 x7,5 5 x45 30 DN 200 DN 200


VSD 5 XVM 45-2 3 400 5 x7,5 5 x10 5 x45 39 DN 200 DN 200
VSD 5 XVM 45-3-2 3 400 5 x11 5 x15 5 x45 50 DN 200 DN 200
VSD 5 XVM 45-3 3 400 5 x11 5 x15 5 x45 58 DN 200 DN 200
VSD 5 XVM 45-4-2 3 400 5 x15 5 x20 5 x45 69 DN 200 DN 200
VSD 5 XVM 45-4 3 400 5 x15 5 x20 5 x45 77 DN 200 DN 200
VSD 5 XVM 45-5-2 3 400 5 x18,5 5 x25 5 x45 88 DN 200 DN 200
VSD 5 XVM 45-5 3 400 5 x18,5 5 x25 5 x45 97 DN 200 DN 200
VSD 5 XVM 45-6-2 3 400 5 x22 5 x30 5 x45 109 DN 200 DN 200
VSD 5 XVM 45-6 3 400 5 x22 5 x30 5 x45 118 DN 200 DN 200
VSD 5 XVM 45-7-2 3 400 5 x30 5 x40 5 x45 128 DN 200 DN 200
VSD 5 XVM 45-7 3 400 5 x30 5 x40 5 x45 136 DN 200 DN 200
VSD 5 XVM 45-8-2 3 400 5 x30 5 x40 5 x45 147 DN 200 DN 200
VSD 5 XVM 45-8 3 400 5 x30 5 x40 5 x45 155 DN 200 DN 200
VSD 5 XVM 45-9-2 3 400 5 x30 5 x40 5 x45 169 DN 200 DN 200
VSD 5 XVM 45-9 3 400 5 x37 5 x50 5 x45 177 DN 200 DN 200
VSD 5 XVM 45-10-2 3 400 5 x37 5 x50 5 x45 188 DN 200 DN 200

921
VSD5
Industrial Boosters

Performance Table

Voltage Motor Power Flow Operating Diameter of Manifold


Model Phase
(V) kW HP (m3/h) Pressure (mWC) Suction Discharge
VSD 5 XVM 64-2-2 3 400 5 x7,5 5 x10 5 x64 26 DN 300 DN 250
VSD 5 XVM 64-2-1 3 400 5 x11 5 x15 5 x64 34 DN 300 DN 250
VSD 5 XVM 64-2 3 400 5 x11 5 x15 5 x64 40 DN 300 DN 250
VSD 5 XVM 64-3-2 3 400 5 x15 5 x20 5 x64 46 DN 300 DN 250
VSD 5 XVM 64-3-1 3 400 5 x15 5 x20 5 x64 53 DN 300 DN 250
VSD 5 XVM 64-3 3 400 5 x18,5 5 x25 5 x64 60 DN 300 DN 250
VSD 5 XVM 64-4-2 3 400 5 x18,5 5 x25 5 x64 66 DN 300 DN 250
VSD 5 XVM 64-4-1 3 400 5 x22 5 x30 5 x64 73 DN 300 DN 250
VSD 5 XVM 64-4 3 400 5 x22 5 x30 5 x64 80 DN 300 DN 250
VSD 5 XVM 64-5-2 3 400 5 x30 5 x40 5 x64 89 DN 300 DN 250
VSD 5 XVM 64-5-1 3 400 5 x30 5 x40 5 x64 96 DN 300 DN 250
VSD 5 XVM 64-5 3 400 5 x30 5 x40 5 x64 103 DN 300 DN 250
VSD 5 XVM 64-6-2 3 400 5 x30 5 x40 5 x64 112 DN 300 DN 250
VSD 5 XVM 64-6-1 3 400 5 x37 5 x50 5 x64 118 DN 300 DN 250
VSD 5 XVM 64-6 3 400 5 x37 5 x50 5 x64 125 DN 300 DN 250
VSD 5 XVM 64-7-2 3 400 5 x37 5 x50 5 x64 133 DN 300 DN 250
VSD 5 XVM 64-7-1 3 400 5 x37 5 x50 5 x64 140 DN 300 DN 250
VSD 5 XVM 64-7 3 400 5 x45 5 x60 5 x64 147 DN 300 DN 250
VSD 5 XVM 64-8-2 3 400 5 x45 5 x60 5 x64 155 DN 300 DN 250
VSD 5 XVM 64-8-1 3 400 5 x45 5 x60 5 x64 162 DN 300 DN 250

VSD 5 XVM 90-2-2 3 400 5 x11 5 x15 5 x85 30 DN 300 DN 300


VSD 5 XVM 90-2 3 400 5 x15 5 x20 5 x85 43 DN 300 DN 300
VSD 5 XVM 90-3-2 3 400 5 x18,5 5 x25 5 x85 52 DN 300 DN 300
VSD 5 XVM 90-3 3 400 5 x22 5 x30 5 x85 64 DN 300 DN 300
VSD 5 XVM 90-4-2 3 400 5 x30 5 x40 5 x85 76 DN 300 DN 300
VSD 5 XVM 90-4 3 400 5 x30 5 x40 5 x85 88 DN 300 DN 300
VSD 5 XVM 90-5-2 3 400 5 x37 5 x50 5 x85 100 DN 300 DN 300
VSD 5 XVM 90-5 3 400 5 x37 5 x50 5 x85 113 DN 300 DN 300
VSD 5 XVM 90-6-2 3 400 5 x45 5 x60 5 x85 124 DN 300 DN 300
VSD 5 XVM 90-6 3 400 5 x45 5 x60 5 x85 135 DN 300 DN 300

922