0% found this document useful (0 votes)
195 views

Electrical Design

1. The document provides general notes for a construction drawing including dimensions being checked on site and dimensions given in millimeters unless noted otherwise. 2. A list of symbols and their descriptions is given for various electrical items including lights, fans, switches, and power sources. 3. Locations of light fixtures, switches, and other electrical points are shown on the plan diagram.

Uploaded by

Trikam Patel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
195 views

Electrical Design

1. The document provides general notes for a construction drawing including dimensions being checked on site and dimensions given in millimeters unless noted otherwise. 2. A list of symbols and their descriptions is given for various electrical items including lights, fans, switches, and power sources. 3. Locations of light fixtures, switches, and other electrical points are shown on the plan diagram.

Uploaded by

Trikam Patel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

GENERAL NOTES

1. DIMENSIONS TO BE CHECKED AS PER THE SITE CONDITION

2. ALL DIMENSIONS ARE IN MM UNLESS MENTIONED

3. DRAWING ARE TO BE READ AND NOT TO BE SCALED

4. ALL DIMENSIONS ARE FROM UNFINISHED MASONARY

5. ANY DISCREPANCY IN THE DRAWING SHALL BE NOTIFIED


TO THE ARCHITECT BEFORE STARTING WORK

DESCRIPTION
SL.NO. SYMBOLS DESCRIPTION
1 2X36W FTL FIXTURE
A/C 705 2510 Socket
1'0" from FFL
[2'-4"] [8'-3"] 2 1X36W FTL FIXTURE

CEILING FAN
3

4 WALL MOUNTED FAN

5 CEILING LIGHT

A/C 6 LIGHT POINT


7 EXHAUST FAN

8
ONE WAY SWITCH
T

9 TWO WAY SWITCH

T Socket TWO WAY


10 5A RAW POWER
1'0" from FFL SWITCH

11 6/16A RAW POWER


12 SWITCH BOARD
UPS
UNDER THE
STAIRS 13 TV CABLE

14 T TELEPHONE POINT

TWO WAY 15
SWITCH
GEYSAR
16 BED LAMP
POINT FOR POINT FOR
CHANDELIER CHANDELIER
17 BELL PUSH

18 CALLING BELL

TWO WAY
SWITCH

TWO WAY
SWITCH

MDB

DB
Socket
TWO WAY 1'0" from FFL Socket
SWITCH 1'0" from FFL

PROJECT
REFRIGERATOR BELL PUSH
POINT
2-WAY NAME Mr.P.S. JAIN
PROJECT NO JY/15/001/
STATUS CONSTRUCTION
SCALE NOT TO SCALE
A/C DATE 09 DECEMBER 2017
AQUA- DRAWING GROUND & FIRST FLOOR ELECTRICAL DRAWING
GUARD
POINT DRAWN BY SURAJ
CHECKED BY ASHRAY

CHIMNEY
POINT

TWO WAY
SWITCH

N
JYAAMITI #662, 6TH CROSS, 17TH MAIN,
3RD BLOCK, KORAMANGALA,
BENGALURU -560034

[email protected]
ARCHITECTURAL STUDIO [email protected]