Logic Plus™: Wiring Devices WWW - Mkelectric.co - Uk
Logic Plus™: Wiring Devices WWW - Mkelectric.co - Uk
Logic Plus wiring devices from MK Electric have been Modern styling
designed to perfectly complement modern interiors, Smoothly formed front plates, rounded rocker switches and chamfered
radius corners
offering an unobtrusive and sophisticated look totally in
keeping with today’s design. Technically, they exceed
Total safety
British Standard requirements with patented features that 3-pin operated “child resistant shutter system”, which is designed to
make these products the most advanced and safest inhibit access to the electricity supply, unless all 3 pins of a standard
available. British 13 Amp plug are in position
They are easy to install and available through our extensive Unrivaled quality and reliability
distributor network. Products are made from the very best materials and are 100% tested
20 year guarantee
Gives total peace of mind to you and your customers (10 years Electronic
Devices)
Logic Plus 19
TERMINAL SCREWS
Backed out and held captive within
the terminal housing
IN-LINE TERMINALS
Allow wire to be cut stripped to the same length
Outboard rockers on switchsockets Combined TV, FM, satellite and Simple but effective screwless cord grip
reduce the likelihood of accidentally telephone sockets save on installation on connection units – securely holds the
switching appliances on or off time and space cable
20 Logic Plus
Specification Switchsocket
Notes Outlets
13 AMP
FLUSH
Switchsocket
Outlets
WITH OUTBOARD
ROCKERS RCD PROTECTED FILTERED
13 AMP 13 AMP 13 AMP
FLUSH FLUSH FLUSH
K2746 WHI K2746 D1 WHI K6211 WHI K6100 WHI K1816 WHI
K2746 GRA K2746 D1 RED K6233 WHI K6300 WHI K1826 WHI
K1800 WHI
K2476 GRA
K2746 WHI 10 K2746 D1 WHI 5 K6211 WHI 1 K6100 WHI 1 K1816 WHI 1
10 5 2 GANG 1 GANG 2 GANG DP
K2746 GRA K2746 D1 RED
10mA RATED TRIPPING CURRENT 10mA RATED TRIPPING CURRENT SPIKE
2 GANG DP 2 GANG DP
ACTIVE CONTROL CIRCUIT ACTIVE CONTROL CIRCUIT 1
WITH OUTBOARD ROCKERS WITH RED OUTBOARD ROCKERS K1816KOWHI
AND DUAL EARTH TERMINALS AND DUAL EARTH TERMINALS K6231 WHI 1 K6300 WHI 1 2 GANG DP
5 5 2 GANG 1 GANG SPIKE WITH
K2746 CE WHI K2476 D1 WHI
30mA RATED TRIPPING CURRENT 30mA RATED TRIPPING CURRENT TAMPERPROOF SCREW
2 GANG DP 5
K2476 D1 RED ACTIVE CONTROL CIRCUIT ACTIVE CONTROL CIRCUIT 1
WITH OUTBOARD ROCKERS
2 GANG DP
K1826 WHI
AND ‘CLEAN EARTH’ FACILITY K6233 WHI 1 K6303 WHI 1 2 GANG DP
WITH RED OUTBOARD ROCKERS, NEONS
5 2 GANG 1 GANG SPIKE AND RFI
K2476 WHI AND DUAL EARTH TERMINALS
30mA RATED TRIPPING CURRENT 30mA RATED TRIPPING CURRENT 1
K2476 GRA 5 K2746 D2 WHI 5 K1826KOWHI
PASSIVE CONTROL CIRCUIT PASSIVE CONTROL CIRCUIT
2 GANG DP
2 GANG DP 2 GANG DP
SPIKE AND RFI WITH
WITH OUTBOARD ROCKERS DUAL EARTH WITH GREEN OUTBOARD ROCKERS AND
TAMPERPROOF SCREW
& NEONS DUAL EARTH TERMINALS
K1800 WHI 5
K2476 CE WHI 5
REPLACEMENT FILTER CASSETTE
2 GANG DP WITH OUTBOARD ROCKERS,
NEONS AND ‘CLEAN EARTH’ FACILITY
MOUNTING BOXES MOUNTING BOXES
FLUSH: 886 ZIC - 35mm deep FLUSH: 886 ZIC
SURFACE: K2140 WHI, 30mm deep SURFACE: K2172 WHI
Earth pin operated shutter. K1816 provides filtering to reduce
voltage spikes only.
These a.c. and pulsating d.c. fault current sensitive products have up to 15mm thick K1826 provides two way filtering to
MOUNTING BOXES frontplates and are suitable for boxes with 30mm min. depth and supply voltages
of 240V 50Hz. reduce voltage spikes and radio
FLUSH: 862 ZIC (25mm) 886 ZIC (35mm for extra wiring space) frequency interference on the mains.
SURFACE: K2142 WHI A 25mm deep box (862 ZIC) can be used but conduit entry is restricted. Protected by thermal cut-out.
K2746 and K2746 D1 are fitted with two earth terminals to provide Refer to Sentrysocket section, page 260, for more information on active and passive
control circuits.
a double earth facility for use when installations are to comply with Section
607 of BS.7671, IEE Wiring Regulations DIMENSIONS: 86 x 146mm
FIXING CENTRES: 120.6mm
K2746 CE is provided with facility for ‘clean earth’ connection BS.7288: 1990
DIMENSIONS: 86 x 146mm All units are a.c. and pulsating d.c. fault current sensitive devices.
FIXING CENTRES:120.6mm Maximum total load 13 amps
BS.1363 Pt.2: 1995 (K2746) and where relevant for K2746 CE
22 Logic Plus
Switchsocket Socket
Outlets Outlets
K1257 WHI K2891 WHI K780 WHI K770 WHI K2251 WHI
K1246 WHI K2893 WHI K781 WHI K771 WHI K2252 WHI
K1246D1WHI
K1257 WHI 10 K2891 WHI 10 K780 WHI 10 K770 WHI 10 K2251 WHI 10
1 GANG DP 1 GANG 1 GANG 1 GANG 1 GANG
5 5 AMP DP SHUTTERED 2 AMP SHUTTERED SHUTTERED
K1246 WHI K781 WHI 5
(NON UK)
2 GANG DP K2893 WHI 10 K771 WHI 10
K781 RED 5
K1257 D1 WHI 10 1 GANG 1 GANG K2252 WHI 5
2 GANG
1 GANG DP WITH RED ROCKER 15 AMP DP SHUTTERED WITH DUAL EARTH TERMINALS 5 AMP SHUTTERED 2 GANG
SHUTTERED
K1246 D1 WHI 5 K2493 WHI 10 K772 WHI 10
(NON UK)
2 GANG DP WITH RED ROCKERS 1 GANG 1 GANG
K1246 D1 RED 5 15 AMP DP SHUTTERED 15 AMP SHUTTERED
2 GANG DP WITH RED WITH NEON
FRONTPLATE AND RED ROCKERS
MOUNTING BOXES AMOUNTING BOXES MOUNTING BOXES MOUNTING BOXES MOUNTING BOXES
FLUSH 25mm FLUSH: FLUSH 25mm FLUSH: FLUSH 25mm
1 GANG: 861 ZIC 861 ZIC (25mm) 1 GANG: 861 ZIC 861 ZIC (25mm) 1 GANG: 861 ZIC
2 GANG: 862 ZIC 866 ZIC (35mm for extra wiring space) 2 GANG: 862 ZIC 866 ZIC (35mm for extra wiring space) 2 GANG: 862 ZIC
FLUSH 35mm (for extra wiring space) FLUSH 35mm (for extra wiring space)
1 GANG: 866 ZIC SURFACE: SURFACE: FLUSH 35mm (for extra wiring space)
K2140 WHI 1 GANG: 866 ZIC K2140 WHI 1 GANG: 866 ZIC
2 GANG: 886 ZIC 2 GANG: 886 ZIC
DIMENSIONS: DIMENSIONS: 2 GANG: 886 ZIC
SURFACE SURFACE
1 GANG: K2140 WHI 86 x 86mm 1 GANG: K2140 WHI 86 x 86mm SURFACE
2 GANG: K2142 WHI FIXING CENTRES: 2 GANG: K2142 WHI FIXING CENTRES: 1 GANG: K2140 WHI
These products are provided with 60.3mm 60.3mm 2 GANG: K2142 WHI
facilities for ‘clean earth’ connection K781 is fitted with two earth
BS.546: 1950 terminals to provide a double earth BS.546: 1950 DIMENSIONS:
and are suitable for non standard plugs 1 gang: 86 x 86mm
with ‘T’ shaped earth pin. facility for use when installations
are to comply with Section 607 of 2 gang: 86 x 146mm
DIMENSIONS: 1 gang: 86 x 86mm BS.7671, IEE Wiring Regulations
2 gang: 86 x 146mm FIXING CENTRES:
DIMENSIONS: 1 gang: 86 x 86mm 1 gang: 60.3mm
FIXING CENTRES: 1 gang: 60.3mm 2 gang: 86 x 146mm 2 gang: 120.6mm
2 gang: 120.6mm
BS.1363 Pt.2: 1995 where relevant FIXING CENTRES: 1 gang: 60.3mm SSA: 444: 1985
2 gang: 120.6mm
BS.1363: Pt 2: 1995
Logic Plus 23
16 AMP
125/250V 16 AMP
UNIVERSAL 2P + E 10 AMP
FLUSH FLUSH FLUSH FLUSH FLUSH
K701 WHI
K4858
K706 WHI
K4155 WHI 10 K4150 WHI 10 K4857 WHI 10 K700 WHI 10 K701 WHI 1
1 GANG 1 GANG WITH SWITCHLOCK SHAVER SOCKET OUTLET SHAVER SUPPLY UNIT
SHUTTERED 16 AMP 250V AND PADLOCK 200-250 VOLTS.50/60Hz DUAL VOLTAGE.
(NON UK) SHUTTERED 10 FUSED. 115/230V OUTPUT
(NON UK)
K4859 WHI Incorporates a self-resetting (220/240V 50/60Hz INPUT)
WITHOUT SWITCHLOCK
overload device, limiting
K4152 WHI 5 10 K706 WHI 1
K4858 current to 20VA.
2 GANG SWITCHLOCK SHAVER SUPPLY UNIT
16 AMP 250V FOR FAN ISOLATOR DUAL VOLTAGE.
SHUTTERED 115/230V OUTPUT
(NON UK) K2000 1 (120/130V 50/60Hz INPUT)
PADLOCK (NON UK)
MOUNTING BOXES MOUNTING BOXES MOUNTING BOXES MOUNTING BOXES MOUNTING BOXES
FLUSH: FLUSH: (35mm) FLUSH: FLUSH: 861 ZIC FLUSH: 878 ZIC
861 ZIC 1 GANG: 866 ZIC 3995 ZIC SURFACE: K2140 WHI SURFACE: K2172 WHI
2 GANG: 886 ZIC
SURFACE: SURFACE: This design incorporates a double
K2140 WHI SURFACE: K2160 WHI wound isolating transformer rated
1 GANG: K2031 WHI Must not be installed in a
bathroom or shower room. 20VA at 230 or 115 volts it meets
2 GANG: K2172 WHI For local isolation of fans with or BS EN 61558 making it safe for use
The universal socket does not without timers for repair or routine Designed for wiring onto in bathrooms. Insertion of a shaver
incorporate an earth contact. These products are not suitable for maintenance.
installation in 25mm boxes lighting circuits plug automatically switches on by
Therefore, appliances needing earth energising the primary side of the
connection (class 1 equipment) DIMENSIONS: DIMENSIONS: 86 x 86mm
DIMENSIONS: 86 x 86mm isolating transformer – removal
must NOT be used with this socket. 1 gang: 86 x 86mm FIXING CENTRES: 60.3mm automatically switches off. The
The socket is intended for use with 2 gang: 86 x 146mm FIXING CENTRES: transformer is protected against
BS, USA and CEE standard plugs. FIXING CENTRES: 60.3mm BS.4573: 1970 overload by an automatic solid
1 gang: 60.3mm BS EN. 60947-3: 1992 state overload device with
DIMENSIONS: 86 x 86mm 2 gang: 120.6mm automatic resetting.
FIXING CENTRES: 60.3mm IEC 60884-1: 2002 DIMENSIONS: 146 x 86mm
BS.5733: 1995 FIXING CENTRES: 120.6mm.
BS EN 61558-2-5: 1998
24 Logic Plus
SWITCHED UNSWITCHED
FLUSH FLUSH
When servicing or
repairing appliances,
fuse carriers remain
attached to the
frontplate when K1030 WHI K1070 WHI K1070 D1 WHI
opened and can be
padlocked for safety 10 10 10
K330 WHI K1040 WHI K337 WHI
DP WITH FLEX OUTLET DP WITH FLEX OUTLET
IN BASE AND THICK FRONTPLATE K1040 KO WHI 10 IN BASE AND THICK FRONTPLATE
K370 WHI 10 DP WITH TAMPERPROOF SCREW K337 KO WHI 10
DP WITH NEON, FLEX OUTLET K1060 WHI 10 WITH FLEX OUTLET
IN BASE AND THICK FRONTPLATE DP WITH NEON IN BASE, THICK FRONTPLATE
An optional 10 AND TAMPERPROOF SCREW
K370 D1 WHI 10 K1060 D1 WHI
tamperproof screw DP WITH NEON AND RED ROCKER
FOR FUSE CARRIER
DP WITH NEON, FLEX OUTLET
on fuse carriers is IN BASE, THICK FRONTPLATE 10 K377 WHI 10
K1070 WHI
particularly useful AND RED ROCKER DP WITH FRONT FLEX OUTLET WITH FLEX OUTLET
for appliances in 10 AND NEON IN BASE, NEON AND
K1030 WHI THICK FRONTPLATE
public areas DP WITH FRONT FLEX OUTLET K1070 D1 WHI 10
DP WITH FRONT FLEX OUTLET,
NEON AND RED ROCKER
MOUNTING BOXES K2000 10 MOUNTING BOXES
K1030, K1040, K1060 and K1070 FUSE CARRIER PADLOCK
FLUSH:
FLUSH: 866 ZIC 866 ZIC (35mm)
SURFACE: K2031 WHI
K1030 and K1070 front flex outlet SURFACE:
In-line terminals, 330 and 370 products cannot be mounted K2140 WHI
FLUSH: 866 ZIC directly onto MI Cable Box K2131.
backed out captive SURFACE: K2140 WHI A mounting frame K2134 will have
All units are fitted with a 13 amp
fuse-link to BS.1362. See page 187
terminal screws and to be used between the product for spare fuse-links.
clear marking make All units are fitted with a 13 amp and the box.
Base entry frontplates are
wiring up easy fuse-link to BS.1362. See page 187 Base entry frontplates are 12.5mm deep
for spare fuse-links. 12.5mm deep
The fuse carrier can be locked in
The fuse carrier can be locked in DIMENSIONS: the open position by removing the
the open position by removing the 86 x 86mm fuse and using K2000 fuse carrier
fuse and using K2000 fuse carrier padlock
padlock FIXING CENTRES:
60.3mm DIMENSIONS: 86 x 86mm
Base entry frontplates are
12.5mm deep BS.1363 Pt.4: 1995 FIXING CENTRES: 60.3mm
BS.1363 Pt.4: 1995
Logic Plus 25
45 AMP
20 AMP 20 AMP 32 AMP MOULDED 45 AMP
FLUSH FLUSH FLUSH FLUSH METAL
K5423WHWHI
K5423D1WHI
K5208 WHI 10 K5403 WHI 10 K5105 WHI 1 K5205 WHI 1 K5230 WHI 1
WITH FLEX OUTLET IN BASE WITH NEON WITH NEON
10 K5215 WHI 1
K5207 WHI 10
SURFACE MOUNTED
WITH NEON K5423 WHI WITH NEON
WITH FLEX OUTLET IN BASE K5012 WHI 1
AND NEON K5215 CK WHI 1 WITH NEON
WITH NEON FLUSH MOUNTED
K5423 WH WHI 10 AND MARKED ‘COOKER’
WITH FLEX OUTLET IN BASE,
NEON AND MARKED K5215 SH WHI 1
‘WATER HEATER’. WITH NEON
AND MARKED ‘SHOWER’
K5423 D1 WHI 10
WITH FLEX OUTLET IN BASE,
NEON AND RED ROCKER
FOR CONTROLLING DUAL MOUNTING BOXES MOUNTING BOXES MOUNTING BOXES K5230
IMMERSION HEATERS Supplied with mounting box. Earth
FLUSH: FLUSH: FLUSH: terminal fitted on base of box.
866 ZIC 866 ZIC (6mm2 conductors) 886 ZIC (6mm2 conductors)
877 ZIC (10mm2 conductors) 878 ZIC (10mm2 conductors) Not recommended for switching
MOUNTING BOXES SURFACE: large banks of PCs
FLUSH: K2140 WHI SURFACE: SURFACE:
K2031 WHI K2140 WHI (6mm2 conductors) K2172 WHI DIMENSIONS: 150 x 89 x 50mm
866 ZIC
(for extra wiring space) K2031 WHI (10mm2 conductors) KNOCKOUTS: 8 x 20mm
SURFACE: K5205 WHI and K5215 WHI
K2140 WHI Base entry frontplates are Supplied with 8 self-adhesive Supplied with 8 self-adhesive TERMINAL CAPACITY:
12.5mm deep. plastic identification labels marked plastic identification labels marked 16mm2 conductors
Only mounting boxes with an earth hob, fan, oven, water heater, hob, fan, oven, water heater,
All switches are complete with BS EN 60669-1: 2000
terminal should be used. shower, air conditioner, cooker and shower, air conditioner, cooker and
earth terminals. washing machine. washing machine.
These products are marked ‘on’ and Not recommended for switching K5012
‘off’ against the one-way DP switch Not recommended for switching Not recommended for switching Not supplied with mounting box.
large banks of PCs large banks of PCs large banks of PCs
and ‘sink’ and ‘bath’ against the FLUSH: 5120 ALM
two-way SP switch. DIMENSIONS: DIMENSIONS: 86 x 86mm DIMENSIONS: 86 x 146mm
86 x 86mm Supplied with earth terminals
DIMENSIONS: 86 x 86mm
FIXING CENTRES: 60.3mm FIXING CENTRES:120.6mm Not recommended for switching
FIXING CENTRES: 60.3mm FIXING CENTRES:
60.3mm BS EN 60669-1: 2000 BS EN 60669-1: 2000 large banks of PCs
BS EN 60669-1: 2000 DIMENSIONS: 178 x 165mm
BS EN 60669-1: 2000
BS EN 60669-1: 2000
26 Logic Plus
Cooker Cooker
Connection Controls
Unit
45 AMP 45 AMP 45 AMP 45 AMP
MOULDED MOULDED METAL METAL
FLUSH FLUSH SURFACE FLUSH SURFACE
K5045 WHI 10 K5060 WHI 1 K5040 WHI 1 K5011 WHI 1 K5001 WHI 1
45 AMP 45 AMP 45 AMP 45 AMP
DP MAIN SWITCH DP MAIN SWITCH DP MAIN SWITCH DP MAIN SWITCH
AND 13 AMP AND 13 AMP AND 13 AMP AND 13 AMP
SWITCHSOCKET OUTLET SWITCHSOCKET OUTLET SWITCHSOCKET OUTLET SWITCHSOCKET OUTLET
WITH NEONS WITH NEONS
K5061 WHI 1 K5041 WHI 1
45 AMP 45 AMP
DP MAIN SWITCH DP MAIN SWITCH
AND 13 AMP AND 13 AMP
SWITCHSOCKET OUTLET SWITCHSOCKET OUTLET
WITH NEONS WITH NEONS
MOUNTING BOX MOUNTING BOXES Supplied complete with mounting MOUNTING BOX Supplied complete with mounting
box and cable restraint. box.
FLUSH: FLUSH: FLUSH:
877 ZIC 886 ZIC: Fitted with earth terminals. 5120 ALM Fitted with earth terminals.
(Up to 6mm2 conductor)
Supplied complete with terminal 878 ZIC: Rotary operated shutter. Fitted with earth terminals. Rotary operated shutter.
block, each terminal of which will (Up to 10mm2 conductor) DIMENSIONS: DIMENSIONS:
accommodate up to two 10mm2 Rotary operated shutter.
86 x 146 x 60mm 156 x 144 x 67mm
conductors. Rotary operated shutter. DIMENSIONS:
DIMENSIONS: BS.4177: 1992 178 x 165mm KNOCKOUTS:
Moulded cover plate, 5 x 25mm.
cable clamp included. 86 x 146mm BS.4177: 1992 Two in each of top and bottom,
FIXING CENTRES: one in back.
120.6mm
DIMENSIONS: BS.4177: 1992
86 x 86mm BS.4177: 1992
FIXING CENTRES:
60.3mm
BS.5733: 1995
Logic Plus 27
Plateswitches
NEON 10 AMP
LOCATOR FLUSH
K3041
K4875 WHI K4879 WHI
K4842 WHI
K1511 WHI K1731 WHI K1541 WHI K3825 WHI K3827 WHI K1090 WHI
K5033 WHI
K1533 WHI K1661 WHI
K1511 WHI 1 K1731 WHI 1 K1541 WHI 1 K3825 WHI 10 K1090 WHI 10
1 GANG SINGLE 1 GANG SINGLE 1 GANG SINGLE 1 GANG MOULDED FLEX OUTLET FRONTPLATE.
ONE WAY 65-450W ONE WAY ONE WAY ARCHITRAVE UNFUSED
K1531 WHI 1 40-250W 75-500W 50Hz 20 AMP RATING
K3827 WHI 10
1 GANG SINGLE 1 1
ONE WAY 40-250W
K1741 WHI K1561 WHI 1 GANG MOULDED
1 GANG SINGLE 1 GANG SINGLE
K1532 WHI 1 K3828 WHI 10
TWO WAY TWO WAY
1 GANG DOUBLE 60-450W 100-1000W 50Hz 2 GANG MOULDED
ONE WAY 2 x 40-250W
1 1 K5033 WHI 1
K1533 WHI 1 K1761 WHI K1631 WHI
2 GANG SINGLE DIMMER 1 GANG SINGLE METAL
1 GANG DOUBLE
TWO WAY 2 x 40-250W TWO WAY ONE WAY
90-650W 40-250W 60Hz
K1534 WHI 1
1 GANG SINGLE K1641 WHI 1
TWO WAY 40-250W MOUNTING BOXES 1 GANG SINGLE K3825 WHI Complete with three pairs of
K1535 WHI 1 FLUSH: ONE WAY For use with 3921 ZIC and K2151 terminals, each suitable for
1 GANG: 861 ZIC-25mm deep min 75-500W 60Hz WHI mounting boxes. 2 x 2.5mm2 conductors and a
1 GANG SINGLE 1.5mm2 flexible cord.
TWO WAY 65-450W 2 GANG: 886 ZIC-35mm deep min K5033 WHI
K1661 WHI 1 A cord-grip is also fitted.
SURFACE: For use with 5120 ALM deep metal
MOUNTING BOXES 1 GANG: K2140 WHI-30mm deep 1 GANG SINGLE box. Frontplate thickness is 12.5mm.
FLUSH: 861 ZIC-25mm deep. With 2 GANG: K2142 WHI-30mm deep TWO WAY Hole diameter is 11mm.
DIMENSIONS:
pattress: 3995 ZIC-16mm deep min DIMENSIONS: 100-1000W 60Hz 3825 WHI: 86 x 31mm DIMENSIONS:
SURFACE: K2140 WHI-30mm deep. K1731, K1741 1 3827 WHI: 86 x 86mm 86 x 86mm
With pattress: K2160 WHI-16mm deep K1539 WHI 3828 WHI: 86 x 146mm
86 x 86mm FAN CONTROLLER FIXING CENTRES:
min 5033 WHI: 178 x 165mm
K1761 1 GANG SINGLE ONE WAY 60.3mm
Only suitable for tungsten filament 146 x 86mm FIXING CENTRES:
lamps. 300 VA 50Hz 3825 WHI: 60.3mm BS.5733: 1995
NOT suitable for fluorescent FIXING CENTRES: 3827 WHI: 60.3mm
lamps or low voltage lighting. K1731, K1741 MOUNTING BOXES 3828 WHI: 120.6mm
DIMENSIONS: 86 x 86mm 60.3mm FLUSH: 861 ZIC-25mm deep min 5033 WHI: 133mm
FIXING CENTRES: 60.3mm K1761 SURFACE: K2140 WHI-30mm deep BS.5733: 1995
Conforms to BS EN 60669-2-1 120.6mm
and BS EN 55015 DIMENSIONS: 86 x 86mm
FIXING CENTRES:60.3mm
30 Logic Plus
MODULAR DATACOMS
Euro Datacom Power Euro Datacom
Frontplates Modules Modules
K181 WHI 10 K5830 WHI 10 K5833 WHI 10 K5887 WHI 5 K5846 WHI 5
1 GANG EURO FRONTPLATE K5887 BLK 5 K5846 BLK 5
K5830 BLK 10 K5833 BLK 10
ONE MODULE RJ11/12 RJ45 CAT 6
APERTURE SIZE 25 X 50MM UK 1 GANG EURO 2 MODULE UK 1 GANG EURO 2 MODULE
ONE MODULE 25 X 50MM ONE MODULE 25 X 50MM
13 AMP 250V SHUTTERED 5 AMP 250V SHUTTERED
K182 WHI 10 5
10 10 K5846s WHI
1 GANG EURO FRONTPLATE K5831 WHI K5834 WHI
K5846s BLK 5
TWO MODULE 10 10
K5831 BLK K5834 BLK RJ45 CAT 6 SCREENED
APERTURE SIZE 50 X 50MM
GERMAN 2P+E FRENCH/BELGIAN 2P+E ONE MODULE 25 X 50MM
K184 WHI 10 16 AMP 250V SHUTTERED 16 AMP 250V SHUTTERED 5
EURO 2 MODULE (NON UK) EURO 2 MODULE (NON UK) K5864 WHI
2 GANG EURO FRONTPLATE
RJ45 CAT 6 ANGLED
FOUR MODULE 10
K5832 WHI ONE MODULE 25 X 50MM
APERTURE SIZE 100 X 50MM
K5832 BLK 10
AMERICAN
MOUNTING BOXES Suitable for both RJ11 and RJ12 Enhanced Cat 6 performance.
15 AMP 127V SHUTTERED
jacks
Suitable for flush boxes to EURO 2 MODULE (NON UK) RJ11; 4 wire Suitable for both 568A and 568B
BS.4662: 1970 and surface boxes RJ12; 6 wire wiring schemes.
to BS.5733: 1995
K5830 K5833 MOUNTING BOXES
Refer to appropriate module for MOUNTING BOX: 35mm minimum MOUNTING BOX: 35mm minimum Minimum box depth 25mm MOUNTING BOXES
minimum box depth. 46mm (for extra wiring space) 46mm (for extra wiring space) FCC68 Minimum Box Depth
DIMENSIONS: 50 x 50mm DIMENSIONS: 50 x 50mm 32mm screened
FIXING CENTRES BS. 1363: Part 2: 1995 BS 546: 1950
1 gang: 60.3mm
2 gang: 120.6mm K5831 K5834 TIA/EIA TSB40A: Cat 6
MOUNTING BOX: 46mm MOUNTING BOX: 46mm TIA/EIA 568-A: Cat 6
BS.5733;1995 where applicable DIMENSIONS: 50 x 50mm DIMENSIONS: 50 x 50mm ISO/IEC11801: Cat 6
Note: No grid required, modules IEC 60884-1: 2002 NF C61-341
just clip into place K5832
MOUNTING BOX: 35mm
46mm (for extra wiring space)
DIMENSIONS: 50 x 50mm
SSA.444: 1985 Mains operated products and extra low voltage modules must not
be installed within the same frontplate. Refer to BS. 7671 IEE
Wiring Regulations for details.
Logic Plus 31
K5844 WHI K5840 WHI K5840 BLK K5820 WHI K5820 BLK K5801 WHI K5801 BLK
K5845s WHI
Enhanced Cat 5 performance. Incorporates line terminating MOUNTING BOXES 50 Ohm crimp connector suitable
Suitable for both 568A and 568B resistor. Minimum depth 16mm for use with RG58, URM43,
wiring schemes. URM76 and Beldon 9907 type
Supplied with cable tie and cable MOUNTING BOXES BS.6312 part 2
Minimum depth 25mm co-axial cables.
anchors to secure wires in the
connectors. TIA/EIA TSB40A MOUNTING BOXES
TIA/EIA 568-A Minimum box depth 25mm
MOUNTING BOXES
Minimum box depth ISO/IEC11801
25mm standard
32mm screened
TIA/EIA TSB40A: Cat 5e
TIA/EIA 568-A: Cat 5e
ISO/IEC11801: Cat 5e
Mains operated products and extra low voltage modules must not be installed within the same frontplate. Refer to BS. 7671 IEE Wiring
Regulations for details.
32 Logic Plus
TV CO-AXIAL OUTLETS
FOR DIGITAL TV
SCREENED
NON ISOLATED BLANKS FRONTPLATES
K172 WHI
K5850 WHI K5850 BLK K5852 WHI K5853 DAB WHI K180 WHI
K5851 WHI K5851 BLK K5852 DAB WHI K5854 DAB WHI K188 WHI K188 BLK
K5855 WHI K5855 BLK K5853 WHI K186 WHI K186 BLK
K5850 WHI 5 K5852 WHI 5 K5853 DAB WHI 5 K180 WHI 10 K172 WHI 10
K5850 BLK 5 K5852 BLK 5 K5853 DAB BLK 5 TWO MODULE 1 GANG TWIN
SINGLE OUTLET (IEC MALE) TWIN OUTLET TRIPLE OUTLET TV-FM/DAB-SAT BLANK 50 X 50MM LJU6C FRONTPLATE
ONE MODULE 25 X 50MM TV/FM DIPLEXER TRIPLEXER TWO MODULE 50 X 50MM TWO MODULE
K188 WHI 10
TWO MODULE 50 X 50MM APERTURE SIZE 22 X 37MM
K5851 WHI 5 K5854 DAB WHI 5 K188 BLK 10
5 K5852 DAB WHI 5 5 ONE MODULE
K5851 BLK K5854 DAB BLK
SINGLE OUTLET (IEC FEMALE) K5852 DAB BLK 5 QUAD OUTLET TV-FM/DAB-2XSAT BLANK 25 X 50MM
ONE MODULE 25 X 50MM TWIN OUTLET TV-FM/DAB DIPLEXER TWO MODULE 50 X 50MM 10
K186 WHI
TWO MODULE 50 X 50MM
K5855 WHI 5 K186 BLK 10
5 K5853 WHI 5 HALF MODULE
K5855 BLK
SINGLE F-TYPE SATELLITE SOCKET K5853 BLK 5 BLANK 12.5 X 50MM
ONE MODULE 25 X 50MM TRIPLE OUTLET
TV/FM/SATELLITE TRIPLEXER
Fully screened non isolated TV TWO MODULE 50 X 50MM MOUNTING BOXES MOUNTING BOXES
outlets containing a combination of Minimum depth 16mm suitable for flush boxes to
single, TV/FM Diplexer and BS.4662:1970 and surface boxes to
TV/FM/SAT Triplexer for use within BS.5733:1995 where applicable BS.5733:1995
digital TV systems and interactive TV/FM diplexer units for connection to a single co-axial aerial lead with Refer to appropriate module for
TV services. Single outlets for combined TV and FM signals. minimum box depth.
connection to a single TV, FM or TV/FM/SAT triplexer units for connection to a single co-axial aerial lead with
Satellite co-axial aerial lead. combined TV,FM and Satellite signals FIXING CENTRES
1 gang: 60.3mm
MOUNTING BOXES PERFORMANCE DIPLEXER AND TRIPLEXER PRODUCTS 2 gang: 120.6mm
Min box depth 32mm
DIMENSIONS SINGLE OUTLETS TV/FM/SAT PRODUCTS BS.5733:1995 where appropriate
1 Module 25 x 50mm OUTLET DIPLEXER TRIPLEXER
TV/FM IEC MALE OR FEMALE TV DC-68.5MHz, 174-862MHz DC-68.5MHz, 174-862MHz Note: No grid required, modules
2 Module 50 x 50mm DC-950MHz just clip into place
FM 87.5-108MHz 87.5-108MHz
BS.3041:1997 SAT F-TYPE SAT N/A DC-200kHz, 950-2400MHz
IEC 169-2:1965 DC-1.75GHz
BSEN 50083 & BS.5733:1995 TV/FM/DAB/SAT PRODUCTS FOR DIGITAL RADIO
where applicable OUTLET DIPLEXER TRIPLEXER / QUAD OUTLET
TV 470-862MHz 470-862MHz
FM/DAB 87.5-230MHz 87.5-230MHz
SAT OR SAT1 N/A 950-2400MHz
These products are fully compatible with Labgear TV distribution systems and SAT2 DC-2300MHz
are approved for use in “Sky Homes” and “Homes On” specifications
Logic Plus 33
LJU6C Datacom
Modules
K5787 WHI K5746 WHI K5745 WHI K5740 WHI K170 WHI
K5787 BLK K5746s WHI K5745s WHI K5740 BLK K170 BLK
K5787 WHI 5 K5746 WHI 5 K5745 WHI 5 K5740 WHI 5 K170 WHI 10
K5787 BLK 5 K5746 BLK 5 K5745 BLK 5 K5740 BLK 5 K170 BLK 10
RJ11/12 RJ45 CAT 6 RJ45 CAT 5E ISDN ONE MODULE BLANK
ONE MODULE ONE MODULE ONE MODULE ONE MODULE
K5746s WHI 5 K5745s WHI 5
K5746s BLK 5 K5745s BLK 5
RJ45 CAT 6 RJ45 CAT 5E
SCREENED SCREENED
ONE MODULE ONE MODULE
Suitable for both RJ11 and RJ12 Enhanced Cat 6 performance. Enhanced Cat 5 performance. Incorporates line terminating MOUNTING BOXES
jacks. Suitable for both 568A and 568B resistor Minimum box depth 16mm
RJ11: 4 wire Suitable for both 568A and 568B wiring schemes.
wiring schemes. MOUNTING BOXES BS.5733:1995 where appropriate
RJ12: 6 wire Supplied with cable tie and cable Minimum box depth 25mm
MOUNTING BOXES anchors to secure wires in the
connectors TIA/EIA TSB40A
Minimum box depth 25mm MOUNTING BOXES TIA/EIA 568-A
FCC68 Minimum Box Depth MOUNTING BOXES ISO/IEC11801
32mm screened Minimum box depth
25mm (unscreened)
32mm (screened)
TIA/EIA TSB40A: Cat 6 TIA/EIA TSB40A: Cat5e
TIA/EIA 568-A: Cat 6 TIA/EIA 568-A: Cat5e
ISO/IEC11801: Cat 6 ISO/IEC11801: Cat5e
34 Logic Plus
FLUSH
K3550 WHI K3552 DAB WHI K3557 WHI K3561 DAB WHI K3563 DAB WHI
K3551 WHI K3553 WHI K3560 WHI K3562 WHI K3564 DAB WHI
K3555 WHI K3553 DAB WHI K3560 DAB WHI K3563 WHI K3565 DAB WHI
K3550 WHI 10 K3552 DAB WHI 10 K3557 WHI 10 K3561 DAB WHI 5 K3563 DAB WHI 5
SINGLE OUTLET TWIN TV/FM SINGLE OUTLET (IEC MALE) TRIPLE TV/FM DAB/SAT TRIPLEXER TRIPLE TV/FM/SAT TRIPLEXER
(IEC MALE) DAB DIPLEXER WITH BT SECONDARY WITH BT SECONDARY WITH SINGLE TV (IEC MALE)
AND BT SECONDARY
K3551 WHI 10 K3553 WHI 10 K3560 WHI 5 K3562 WHI 5
SINGLE OUTLET TRIPLE TV/FM/SAT TWIN TV/FM DIPLEXER TWIN TV/FM DIPLEXER K3564 DAB WHI 5
(IEC FEMALE) TRIPLEXER WITH BT SECONDARY WITH SINGLE TV (IEC MALE) QUAD TV/FM DAB/SATX2 QUADPLEXER
AND BT SECONDARY WITH BT SECONDARY
K3555 WHI 10 K3553 DAB WHI 10 K3560 DAB WHI 5
SINGLE OUTLET TRIPLE TV/FM DAB/SAT TWIN TV/FM DAB DIPLEXER K3563 WHI 5 K3565 DAB WHI 5
F-TYPE SATELLITE SOCKET TRIPLEXER WITH BT SECONDARY TRIPLE TV/FM/SAT TRIPLEXER QUADPLEXER + RJ45
WITH SINGLE TV (IEC MALE) AND BT SECONDARY
K3552 WHI 10 K3554 DAB WHI 10 K3561 WHI 5 AND BT SECONDARY
TWIN TV/FM QUAD TV/FM DAB/SATX2 TRIPLE TV/FM/SAT TRIPLEXER
DIPLEXER QUADPLEXER WITH BT SECONDARY
Fully screened non isolated TV Single outlets for connection to a TV/FM/SAT triplexer units for BT Telephone Secondary outlet for
outlets containing a combination of single TV, FM or Satellite co-axial connection to a single co-axial use with interactive TV digital
single,TV/FM Diplexer, TV/FM/SAT aerial lead. aerial lead with combined TV, FM services.
Triplexer and secondary telephone TV/FM diplexer units for connection and Satellite signals
outlets for use within digital TV to a single co-axial aerial lead with K3562 and K3563 outlets with
systems and interactive TV services. combined TV and FM signals. additional single TV (male) outlet
for secondary distribution of TV
signal
K3636 WHI
K3520 WHI 10 K3521 WHI 10 K3631 WHI 10 K3636 WHI 1 K3639 WHI 1
SINGLE OUTLET SINGLE OUTLET 12 MODULE
K3631 GRA 10 K3636 GRA 1
K3523 WHI 10 K3522 WHI 10 1 MODULE 6 MODULE
TWIN OUTLET TWIN OUTLET
K3632 WHI 10 K3638 WHI 1
WITH FM/TV DIPLEXER
K3525 WHI 10
K3632 GRA 10 K3638 GRA 1
SINGLE F TYPE
SATELLITE SOCKET 2 MODULE 8 MODULE
10 K3633 WHI 10
K3525 D1 WHI
TWIN F TYPE K3633 GRA 10
SATELLITE SOCKET 3 MODULE
K3634 WHI 10
4 MODULE
MOUNTING BOXES MOUNTING BOXES
FLUSH: FLUSH:
861 ZIC 861 ZIC
SURFACE: SURFACE:
K2140 WHI K2140 WHI
Provides safety isolation rated at All modules from the Grid Plus
Single outlet for connection to a 2000Va.c. between aerial lead and range can be used with these
single TV or FM co-axial aerial lead. socket. frontplates.
Twin outlet for connection to each Single outlet for connection to a
of two separate TV/FM, co-axial single TV or FM co-axial aerial lead. DIMENSIONS:
aerial leads. Twin outlet with TV/FM diplexer for 1 & 2 MODULE: 86 x 86mm
connection to single co-axial aerial 3 & 4 MODULE: 86 x 146mm
DIMENSIONS: 86 x 86mm lead with combined TV & FM
FIXING CENTRES: 60.3mm signals. 6 & 8 MODULE: 146 x 146mm
12 MODULE: 206 x 146mm
BS. 5733: 1995 DIMENSIONS: 86 x 86mm
where applicable BS. 5733: 1995
FIXING CENTRES: 60.3mm
BS.3041: 1977 BS. 5733: 1995 where applicable
IEC 169-2: 1965 BS.3041: 1977 IEC 169-2: 1965
Case Study
MK wiring devices and Ackermann underfloor boxes A Heritage Lottery Fund of nearly £2million helped to finance
are installed in the futuristic new John Fieldhouse the construction of the building, which is named after the late
Building at the Royal Navy Submarine Museum, Admiral of the Fleet, Lord John Fieldhouse of Gosport, the
Gosport. most senior submariner in history. The ground floor contains a
combined information and reception area, plus lecture and
Shaped like a submarine, the building houses the corporate entertainment facilities. On the first floor is a new
reconditioned historic mini-submarine HMSX24, ‘Submarine and Science’ gallery containing seven themed
which was previously installed on an outside site aspects of submarine-related topics, such as oceanography.
where exposure to the elements was causing There is also a 60m2 space for temporary exhibitions.
deterioration of the submarine. The 51ft2 X24 was
one of several submarines that went on daring Electrical installation was the responsibility of the Portsmouth
missions during World War II. These operations Branch of Southern Electric Contracting, this and last year’s
included reconnaissance for the D-Day landings, and winner of the Major M&E Contractor Building Services Award.
some of the four-man crews received the Victoria SEC also produced the winner of the 2005 MK Apprentice of
Cross for their bravery. the Year, Douglas Orrell, who worked on the Fieldhouse
building.