Xpthc-4: Arc Voltage Plasma Height Controller
Xpthc-4: Arc Voltage Plasma Height Controller
,LTD
Tel:+86-755-26625800
Fax:+86-755-26729960
Http://www.hydcnc.com
XPTHC-4
Arc Voltage Plasma Height Controller
SAFETY:
Installation Note:
Power supply: AC 24V or DC 24V
Please offer the enough power supply: usually, 25W motor, the current couldn’t be
less than 3A, the AC24V transformer couldn’t be less than 50W.
Power supply= 2*motor’s power + 10W
GND Must follow THC instruction, GND resister≤4Ω。
UP/DOWN on THC must be same to Z-axis Lifter
To avoid interference, follow cables please use shield cable( connection between
CNC controller and THC, to motor, to voltage divider, to IHS card), especially the
cable from THC to voltage divider, please use shield twisted pair cable, and shield
net connected at THC side.
The plasma raw arc couldn’t connect to the THC directly, must connect to the
voltage divider correctly.
To Customer:
We only supply to re-seller as CNC cutting machine manufacturer, engineering
company… end-user please contact our local distributor for product
supplying.
We offer technical support to all distributors and users of our product.
。
IMPORTANT NOTE:
All our THCs have been tested on CNC cutting machine in our workshop
before delivery, all commissioning work was done. Please DO NOT change the
setting without informing your supplier.
Contents
1. Brief info ............................................................................................................................. 1
1.1 Product name and model......................................................................................... 4
1.2 Application ................................................................................................................ 4
1.3 Basic Parameter ....................................................................................................... 4
1.4 Components and installation .................................................................................. 5
2. XPTHC-4 Function and Setting......................................................................................... 8
2.1 Function .................................................................................................................... 8
2.2 XPTHC-4 operation panel ...................................................................................... 10
2.1.1Operation panel instruction Fig2-1 .............................................................. 10
2.2.2 Keys and LED light....................................................................................... 10
2.3 XPTHC-4 Brake adjusting and sensitivity adjusting............................................ 12
2.4 XPTHC-4 Parameter setting and Alarm diagnose…………………………………..12
2.4.1 Parameters details ....................................................................................... 13
2.4.2 Alarm codes details ..................................................................................... 14
3 .XPTHC-4 Connection ........................................................................................ 17
3.1 Power ............................................................................................................... 18
3.2 To IHS1 .......................................................................................................... 18
3.3 TO IHS2 ............................................................................................................ 18
3.4 TO CNC ............................................................................................................ 20
3.5 TO TORCH........................................................................................................ 21
3.6 TO PLASMA ..................................................................................................... 21
3.6.1 Voltage divide info ............................................................................................... 22
4. XPTHC-4 Diagram wiring ................................................................................................ 23
XPTHC-4 is the newest design THC, special for portable CNC cutting machine and small
bench type machine, with 32 ARM processors, and analogous circuit height control together.
Feature:
1, installation: user could install the THC’s operation panel on the work interface, or install
it at the convenient operation place. Install the main body at a suitable station.
2, height controller: could change the auto cutting height at any time
3, two modes of the setting arc volt:
A, Setting arc volt mode: set the setting arc volt on the operation panel, let the THC
work on the setting arc volt status. It’s the traditional work way.
B, sampling arc volt is the setting arc volt: when the THC control the torch finish the HIS
and plasma start, and CNC controller open the AUTO signal to THC, and THC will test the arc
XPTHC-4 is with full functions of the Stand alone Arc Voltage Torch Height Controller. But
as it’s with small body, the motor of the lifter should be less than 20W on the portable CNC
cutting machine, light gantry machine and small bench type machine etc.
D、RS232 A、XPTHC-4
Cables Control Module
B、operation
panel
E、Proximity
Switch C 、 Voltage
divider
1.4.2、Installation
A、XPTHC-4 control module installation size
Fig 1-3
Fig 1-4
Installation Size
Fig 1-5
C、Arc Voltage divider installation size
Plasma Arc Voltage is divided by Arc Voltage Divider (offered with THC) on 50:1 via none isolate
voltage divide, lead into THC after processed by Isolation Circuit. It can be installed inside of the plasma
or cnc control cabinet. (must use the shield cables)).Follow the fig 1-6 shows.
Anti-collision function
When THC stops work, it’ll send the collision signal within 0.2 second if any material
touches the torch and actives the proximity switch.
During auto work, except for IHS, it’ll send the collision signal within 0.2 second if any
material touches the torch and actives the micro switch or proximity switch. The collision
signal is using 200mA optical coupler OC door output, it could connect to the CNC’s collision
input directly.
Offering E1 to E5 warnings
E1:Communication error
E2:Corner signal logic setting error
E3:ARC detect failure
E4:Over-voltage protection (actual arc voltage - setting arc voltage> 30V ), it works at the
setting arc volt mode, doesn’t work at the sample arc volt mode.
E5:Collision warning
Parameter
codes and
alarm codes
8 function
LED lights
THC Auto work status: press and hold it to show the setting arc voltage. Checking the difference of the
setting arc volt and the actual arc volt.
When at the “P” status, press the “MENU” to save all the setting parameters.
(ARCON TEST)&SET:
1、In work stop status: press and hold it to test the arc start, press it until the plasma arc start,
loose it plasma arc stop.
2、setting status: press it one time to set parameters(SET)
UP/DOWN:
In work stop status: control the torch to go up and go down;
THC Auto work status: adjust the setting arc voltage, means to change the cutting height;
Setting status: change the parameter number and value
AUTO:
In work stop and THC auto work status: press it ON the auto or OFF the auto function. When stop
status, “AUTO” light is blink, means THC is allowed on auto status, if press “AUTO”, then the “AUTO”
light is off, then means the THC is on manual status.
Setting status: confirm the parameter setting(ENTER), will show “P” status on it.
IHS TEST
In work stop status: for IHS test; press it, begin the IHS, after the IHS finished, automatically
recover, or press this button or “UP” button to recover it.
Other status: no valid
8 Function LED indictors:
UP/DOWN: LED light turn on when torch go up/ go down.
ARCON: LED light turn on when THC has detected the arc start signal. If arc start
with IHS enable, this LED light is turn off until IHS completed.
AUTO: LED light turn on means THC is on AUTO mode. 4 conditions must be
satisfied:
1. In work stop status, “AUTO” LED light is blink, means THC panel allows it at the
AUTO status;
2. CNC send the arc start signal;
3. CNC Auto Height Control(THC) enables;
4. THC finds the divided arc volt from CNC( Trans turns on); Actual Arc Voltage is
not higher than setting Arc Voltage over 30V.
TRANS:LED light turn on when THC find divided arc get into THC, and send out the pierce
complete signal to CNC.
IHS: LED light turn on when do IHS.
UP_Limit:LED light turn on when torch go to up limit.
DN_Limit: LED light turn on when torch go to down limit.
Note: Press “UP” and ”DOWN” buttons When THC in work stop status, can be let the torch go up
and down.
When finished ARC start, press “MENU” use to monitor the setting arc voltage, and in
this status if press “UP”or “DOWN”, then to change the setting Arc Voltage or
Sampling Arc Voltage. When at stop status, it’s for set the parameters.
During THC power on and setting parameter, some LED lights will be blink , that’s according to the
different setting status.It’s use for remind the setting parameter’s meaning.
Brake-ADJ SEN-ADJ
(Brake adjusting) (Sensitivity adjusting)
Note:If sensitivity is too high, the torch would be shake, please test it carefully.
XPTHC-4 is tested on the 2800mm/min with lifter, so for 1000mm/min—3000mm/min speed
with lifter, user no need to adjust it. If user need the speed over 3000mm/min, then need
to decrease the sensitivity a little, according to the cutting situation (If it shake during
cutting, please decrease the sensitivity).
Sensitivity matters to the quality of lifter. If the lifter can lift torch up/down on with DC
motor Power Supply below 3V, it is qualify lifter for XPTHC-4.
off
proximity 0 0,1 0:low level effective,1: high level effective.
switch IHS If using the NPN(NO) proximity switch, the
logic “P9” value should be “1”;
If using the NPN(NC) proximity switch, the
“P9” value should be “0”
(NO: normally open; NC: normally closed.)
Alarm
Description Alarm reason Solution
code
1、 Connect the cables well again,
checking whether there has a poor
Wrong connection in cables connection or wrong connection;
Communica
between operation panel and THC 2、 Circuit board fault;
tion error
control module . Will be solved after correct
connection.
3、 XPTHC-4 Connection
INPUT POWER(AC24/
Motor cable GND TO CNC TO Proximity DC 24V)
Switch (IHS2)
+15V
SIGNAL
COM
Note:
A、 ALL to CNC controller’s signals use optical isolation, original set is low-level
effective.
B、 Arc OK signal(arc feedback 1、arc feedback 2)is a switch signal.
C、Arc feedback signal adopts the 200mA NPN OC door output, it could connect to the
input of the CNC’s arc enable directly, also could connect to the 24V/100mA relay.
TO CNC pin definition as follow:
Pin(s) Signal Description & Ratings
Auto Signal,Control level depends on P7
parameter setting,
1 EXAUTO
Controlled by CNC’s corner signal or THC
enable signal, Pin8 is control Com
Up signal, low-level effective
2 UP
Pin8 is control Com
Down signal, low-level effective
3 DOWN
Pin8 is control Com
ARC ON with IHS
Arc start with IHS, low-level effective
4 (IHS_ARCON)
Pin8 is control Com
Arc volt -
Arc volt +
Plasma
start 1; start2
Due to None Isolation Voltage Divide is directly connected with Plasma Power Supply, to
enable THC escape from interference caused by the HF during Plasma Arc Start, the Divided
Arc Voltage guided into THC is Time-Delayed. It just needs to prolong the time of lead Arc
Voltage into THC, this interference can be avoid effectively.
On XPTHC-4, the delay lead in arc volt into THC is setting by P2 parameter on the
operation panel.
According to Fig 3-8, only need to do with these three Resistors. After that then
could use plasma’s own voltage divider output.
5、Important :
1、XPTHC-4 is a new and smart THC with full function, while it’s designed for small
motor(<25W), so please don’t use it for a lifter which motor is more than 30W, avoid to
any damaged.
2、XPTHC-4 performance is no relationship with plasma’s current
3、Welcome to advise any suggestion and comment, it’ll help our company design and
develop good products to customers.