0% found this document useful (0 votes)
44 views

TDR10003P DS en

The TDR1000/3P is a handheld time domain reflectometer for locating faults on metallic cables up to 5 km. It has a simple auto setup and trace HOLD feature for comparing cables. The IP54 rated device can identify near end faults with a 2 ns pulse and has adjustable display contrast for outdoor use.

Uploaded by

Mutahirrasool
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views

TDR10003P DS en

The TDR1000/3P is a handheld time domain reflectometer for locating faults on metallic cables up to 5 km. It has a simple auto setup and trace HOLD feature for comparing cables. The IP54 rated device can identify near end faults with a 2 ns pulse and has adjustable display contrast for outdoor use.

Uploaded by

Mutahirrasool
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

TDR1000/3P

Handheld TDR

TDR1000/3P
Handheld TDR

■■ Simple operation
■■ AUTO set up for instant use
■■ Ultra fast pulse for near end fault
identification
■■ Trace HOLD feature to allow comparison
between cables
■■ IP54 rating offers real life working
■■ Designed for use on all metallic cable
pairs

DESCRIPTION FEATURES AND BENIFITS


The TDR1000/3P is a hand held, compact Time Domain Reflectometer An AUTO selection option ensures that the most effective parameters
for locating faults on metallic cables. It has a minimum resolution are selected depending on the range required, aiding rapid diagnosis
of 0.1 m/0.3 ft and a 5 km/15 kft maximum range depending on of the TDR trace. Dual cursors allow complete flexibility, giving the
velocity factor selected and cable type. operator full control and instant indication of distance between two
Four output impedances are available (25, 50, 75, and 100 Ω) and points.
a velocity factor between 0.2 and 0.99 will meet any cable test A trace HOLD feature also allows comparison between conditions,
requirements something not seen on most other handheld TDRs. Extra high
The TDR1000 has a simple selection option which together with a 4 resolution together with white-light backlight and grey scale tones
way control switch offers an intuitive operation for the user. give the graphical display a vibrancy, aiding the user in identifying
key events on the trace.
nn Backlit graphics monochrome LCD (256 x 128)
nn Adjustable display contrast
nn Resolution to 0.1 m
nn For use on Telecom TNV-3 circuit, or 150 V CAT IV power
circuits
nn Power blocking filter not required
nn Environmental protection to IP54
nn Auto selected output impedance
(between 25, 50, 75 and 100 Ω)
nn 2 ns pulse for near end fault location
nn AUTO option selecting gain and pulse for each range
nn Display distance in metres or feet
nn Uses five AA (LR6) primary cells
TDR1000/3P
Handheld TDR
SPECIFICATIONS Case ABS

Range 10 m, 25 m, 100 m, 250 m, Connectors Two 4 mm-safety terminals


1000 m, 2500 m, 5000 m Test lead (19 mm spaced TDR1000/3P):
(30 ft, 75 ft, 300 ft, 750 ft, 1 pair 1.5 m retractable sheath,
3000 ft, 7500 ft, 15000 ft) fitted with 500 mA FF HBC 1 kV
Accuracy ±1% of range ± pixel at 0.67 VF 50 kA fuse

[Note- The measurement accuracy is for the indicated cursor Display 256 x 128 pixel Graphics LCD
position only and is conditional on the velocity factor being correct.] Operating temperature range and humidity
Resolution 1% of range -15 °C to +50 °C (5 °F to 122 °F)

Input protection This instrument complies with Storage temperature range and humidity
IEC61010-1 for connection to live -20 °C to 70 °C (-4 °F to 158 °F)
systems up to 150 V CAT IV when Safety When using the supplied fused test
used with the supplied fused test lead set this instrument complies with
lead set. IEC61010-1 for connection to live
Output pulse 5 volts peak to peak into open circuit. systems with less than 300 V
between the terminals and up to
Pulse widths determined by range 150 V CAT IV to earth
and cable
EMC Complies with Electromagnetic
Gain Set for each range with three user Compatibility Specifications
selectable steps (in Manual (Light industrial) BS EN 61326-1,
operating mode) with a minimum performance of
Velocity factor Variable from 0.2 to 0.99 in steps ‘B’ for all immunity tests
of 0.01
TX null Automatic
Power down Automatic after 5 minutes with
no key press
Backlight Stays on for 1 minute with
no key press
Battery Five LR6 (AA) type batteries,
Manganese alkali or nickel
metal-hydride cells
Battery life Up to 14 hours (Typical)
Dimensions 230 x 115 x 48 mm
( 9.0 x 4.5 x 2.0 inches)
Weight 0.6 kg (1.32 lbs)

ORDERING INFORMATION
Description Part number Description Part number
Time Domain Reflectometer 1001-789 Included accessories
Hard case
User guide CD
Retractable sheath fused test lead (1 pair)
Optional accessories
Miniature clip test lead set (1 pair) 6231-652
Red and black probes and clips -
for use with all Megger TDR Fused Test Leads. 1002-491
Split conductor fused test lead set (1 pair) 1002-015

SALES OFFICE TDR10003P_DS_en_V07