Aquavolt+: Precision Moisture Analyzer

The AquaVolt+ is a precision moisture analyzer that provides accurate and calibration-free trace moisture analysis down to very low ppbV levels. It is suitable for a wide range of applications including semiconductor manufacturing, specialty gases, aerospace and military uses. The compact and easy to use device has adjustable outputs, mass flow control, on-line verification capabilities, and reliable electrolytic sensors. It offers flexible configuration, field upgradable software, and a two-year service warranty.

Uploaded by

Doge Captain
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
111 views

Aquavolt+: Precision Moisture Analyzer

The AquaVolt+ is a precision moisture analyzer that provides accurate and calibration-free trace moisture analysis down to very low ppbV levels. It is suitable for a wide range of applications including semiconductor manufacturing, specialty gases, aerospace and military uses. The compact and easy to use device has adjustable outputs, mass flow control, on-line verification capabilities, and reliable electrolytic sensors. It offers flexible configuration, field upgradable software, and a two-year service warranty.

Uploaded by

Doge Captain
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

AquaVolt+

Precision Moisture Analyzer


Industrial Gas Electronic Gas Natural Gas Medical & Aviation Aerospace & Military Glove Box Specialty Gases

Reliable and longstanding staple of the high purity gas industry, the AquaVolt+ provides accurate, calibration-
free technology for trace moisture analysis to very low ppbV. It excels across a range of applications,
among them:
● Semiconductor manufacturing ● Government research and industrial
● Refrigerant gases, such as C3H2F6, CF4, laboratories. Example: DNA research for drug
CH2F2, and CH3F, among others, used to etch development and genetic therapies
polysilicon and for Chemical Mechanical ● Shielding gases for orbital welding
Planarization (CMP) ● Aerospace and military
● Specialty gas applications, including Silane ● Helium and Nitrogen Gases: ~ 0.5 to 1 ppmV
used for wafer deposition and more for tube trailer moisture verification
● Hexafluoroethane (C2F6) for semiconductor ● Pressure Swing Adsorbers (PSAs) used in
tool chamber cleaning, removal of silicon Helium Recovery
dioxide from silicon wafers, and plasma etch ● Mobile cart applications

Well thought out features save space, ease operation, and boost confidence, including:

❑ Compact, flexible footprint: Two analyzers can fit neatly into ONE 19” RACK!

❑ Ease of Use: User-friendly keypad interface, bright vacuum fluorescent display (VFD) and helpful
menu-driven prompts make it simple to specify, to configure, and to start up for your specific
application.

❑ Flash upgradable software: Easily upgrade unit software via RS232 port.

❑ Adjustable outputs: Flexibility to change output scales in the field. No need to replace electronic
components or open the analyzer. Simply open the menu via Mode/Enter key and select Output scale.

❑ Mass Flow Control: Select your sample gas from the main menu and the microprocessor
automatically adjusts the mass flow controller to the proper set point.

❑ On-line verification: Conveniently verify proper cell operation using simple Delta Flow procedure to
check sensor linearity and performance on-line.

❑ Consistency and precision: The reliability and accuracy of MEECO’s time-proven electrolytic
sensors are unique among its peers. When you have been doing something since the early 1950’s,
you approach perfection...
AquaVolt+
Specifications:
Detection Limit (LDL): 35 ppbV

Operating Range (for


0-20 ppmV; for Oxygen, the range is 0-12 ppmV
inert gases):

Accuracy: ±5% of reading or 0.4 ppmV, whichever is greater


In Oxygen: ±20% of reading or 100 ppbV, whichever is greater.

Cell type (P2O5) AILR, AOLR, AHLR

Inert gases, Oxygen, Hydrogen, Clean Dry Air (CDA), Methane, Ethane, Propane, Normal
Gas Matrices Library: Butane, Isobutane, Carbon, and others, including gas mixtures. For other gases, please
consult factory.

*For Oxygen (mixtures) AOLR cell is required, for Hydrogen (mixtures) AHLR cell is required.

Inlet Pressure: 10-3000 psig (0.7 – 207 bar).

Operating
0°C to +60°C (32°F to +140°F), maximum 80% RH non-condensing
(Ambient) Conditions:

Cell: 100 sccm


Flow Rate:
Bypass 1000 sccm
Display unit options: ppmV, ppbV, ºC or ºF dewpoint

Gas Connections: Inlet: 1/4” VCR, Outlet: 1/8” compression. Bypass outlet 1/8” compression

Field Configurable Isolated 0-5 VDC or Isolated Current Output 4-20mA, 0-20mA, or 0-24 mA --
Signal Output:
RS - 232 Communications – Standard

Alarms: Two (2) user-adjustable moisture levels

Electrical: 100 – 240 VAC, 50/60 Hz, 50 watts.

User Interface: 5-key Membrane Keypad. 2-line x 20-character Vacuum Fluorescent Display (VFD).

Weight: 22 lbs. (10.0kg)

Dimensions
7” x 8.19” x 14.66” (17.78 cm x 20.80 cm x 37.24 cm)
(H x W x D):

Mounting Standalone (Optional: 19” Rack Mount (Size: 7”x 19” x 17” (17.8 cm x 20.3 cm x 35.6 cm))

Approval: CE Mark

Service with a Big Smile 😎: The AquaVolt+ comes with a full two-year Certificate of Calibration. The cell can
easily be replaced in the field, with no need to disconnect the unit from the sample stream! Also, spare cells now
have a two-year storage life if kept in their sealed shipment bags.