Tap Stand Type 1 - Tap Stand To Be Constructed On Natural Ground
Tap Stand Type 1 - Tap Stand To Be Constructed On Natural Ground
90
REINFORCED REINFORCED
CONCRETE CONCRETE
TAP STAND TAP STAND
10 MM DIA. DEF. BARS
0.15 0.05 SPACED AT 0.20 M OCBW 4-10 MM DIA. DEF. MAIN BARS
BRASS FAUCET BRASS FAUCET
0.15 WITH 10 MM DIA. TIES
1
2"90 DEG. SPACED AT 0.15 M OC
GI ELBOW
WATER METER 0.20
1% SLOPE
0.60
3
1.00
1.00 4"DIA. GI PIPE 0.90 1.00 0.04
DISTRIBUTION LINE TAP 0.05
0.05 0.05 0.05
0.10
1% SLOPE SLOPE 2%
0.20
0.15
0.10 0.15 0.30
1.00
10 MM DIA. DEF. BARS
1/2" DIA. GI PIPE
SPACED AT 0.3 M. OCBW
1.50 DISTRIBUTION LINE TAP 10 MM DIA. DEF. BARS
0.25 1.00
REINFORCED CONCRETE 0.20 SPACED AT 0.30 M OCBW
WATER DISTRIBUTION LINE FAUCET PAD
WATER METER
2-FAUCET TAP STAND PLAN 1-FAUCET TAP STAND PLAN WATER DISTRIBUTION LINE
2-FAUCET TAP STAND DETAIL 1-FAUCET TAP STAND DETAIL
SCALE 1:16 SCALE 1:16
SCALE 1:16 SCALE 1:16
1.50
0.15
0.70
1.00
0.15
0.20
0.28
0.15 0.15
0.05
0.15 0.15
1.00 CONCRETE METER
0.20
1.20 BOX WITH COVER
AND LOCK
2-FAUCET TAP STAND FRONT ELEVATION 2-FAUCET TAP STAND LEFT SIDE ELEVATION 1-FAUCET TAP STAND FRONT ELEVATION 1-FAUCET TAP STAND LEFT SIDE ELEVATION
SCALE 1:16 SCALE 1:16 SCALE 1:16 SCALE 1:16
REPUBLIC OF THE PHILIPPINES PROJECT NAME AND LOCATION: SHEET CONTENTS: PREPARED BY: REVIEWED BY: RECOMMENDING APPROVAL: APPROVED: SHEET NO.
PHILIPPINE RURAL
DEVELOPMENT PROJECT
DEVELOPMENT OF TIWI POTABLE WATER SYSTEM 31
MUNICIPALITY OF TIWI PUBLIC FAUCET TYPE 1 DETAILS
LOCATION: Tiwi, Albay ENGR. MABEL P. KALLOS ENGR. ERIC MONICO B. BUSTILLO ENGR. EDMUND C. DANTES JAIME C. VILLANUEVA 167
PROVINCE OF ALBAY ENGINEERING ASSISTANT MUNICIPAL ENGINEER MPMIU/MPDO MUNICIPAL MAYOR
DATE: DATE: DATE: DATE: