Commander C Datasheet
Commander C Datasheet
COMMANDER C
Power & Control
100 V drive: 100 V to 120 V ±10 %
200 V drive: 200 V to 240 V ±10 %
400 V drive: 380 V to 480 V ±10 %
575 V drive: 500 V to 575 V ±10 %
Supply Requirements
690 V drive: 500 V to 690 V ±10 %
Maximum supply imbalance: 2 % negative phase
sequence (equivalent to 3 % voltage imbalance
between phases)
Input Displacement Power Factor 0.97
Reference standard IEC60068-2-27, IEC60068-2-29 bump test, IEC60068-2-64 random vibration test, IEC60068-2-6,
Vibration
EN61800-5-1 sinusoidal vibration test. Tested to Environmental Category ENV3
Mechanical Shock Tested in accordance with IEC 60068-2-27 and IEC 60068-2-29
E171230
C300 models only: The Safe Torque Off (STO) function may be used as a safety component of a machine.
Type examination certificates by TÜV Rheinland:
Frame sizes 1 - 4: No. 01/205/5383.03/18
Frame sizes 5 - 9: No. 01/205/5387.02/18
TÜV
Functional safety parameters:
EN ISO 13849-1 - Cat 4, PLe
EN61800-5-2/EN62061/IEC 61508 - SIL 3
UL functional safety approval: FSPC E171230
IEC/ EN 61800-3 Immunity and Emissions
EN 61000-6-2: Immunity for industrial environments
Product EMC Standards EN 61000-6-4: Emissions for industrial environments
EN 61000-3-2: Harmonic current emissions
An EMC data sheet is available on request
ISO Manufacturing facilities comply with ISO 9001:2015 and ISO 14001
Warranty
Warranty 5 Years (warranty terms and conditions apply)
Accessories
Remote Interfaces Remote keypad IP66 Remote, IP66 RTC Keypad , HMI
AI-485 24 V Adaptor, SI-EtherCAT, SI-PROFIBUS, SI-Ethernet , DeviceNET, SI-CANopen, SI-PROFINET , SI-POWERLINK, SI-
Communication & Feedback, SI-Options
Encoder
2
AI-Back-up Adaptor
Back-up & Cloning
AI-Smart Adaptor
Protection
Conformal Coating 100 % Coverage
100 V models: 175 Vdc
200 V models: 175 Vdc
DC Bus Undervoltage Error Level 400 V models: 330 Vdc
575 V models: 435 Vdc
690 V models: 435 Vdc
Frame sizes 1 - 4:
Motor Thermal Protection Electronically protects the motor from over-heating due to loading conditions
Keep Running Parameter set to avoid errors and machine downtime (needs to be configured)
Dedicated Thermistor Input Avoid downtime or machine damage due to overheated motor
General
Items supplied with the drive Step-By-Step Guide, Safety Information, Grounding bracket (Frames 1 to 4), Surface mounting brackets (frame 5 to 9)
FUNCTIONALITY
Modbus RTU Communications
(available with AI-485 Adaptor)
Control Word Control
Cloning
On Board PLC
• CODESYS based
User Software Tools • Included programming languages: ladder diagram, structure text, function block diagram,
(Free to Download) instruction list, sequential function chart, continuous function chart
• Function block libraries
• On-line monitoring of program variables with user defined watch windows
• Support for on-line change of program
Pre-set Programs
Unbalanced Load Detection (Laundry Application)
(Available on Request)
Reference
4 (Selectable: Analogue Ref. 1, Analogue Ref. 2,
Selectable References
Pre-set Frequency Ref., Keypad Ref.)
Jog Reference
Bi-Polar Reference
Pre-set Speeds 8
Pre-set Timer
Skip Frequencies 3
Local/Remote
S-Ramp
Acceleration Rates 8
Deceleration Rates 8
Run Reverse
Torque Reference
Application Specific
PID Feedforward
Reference Configuration
Run/Stop Configuration
Input Scaling
Limit Switches
Control
Slip Compensation
Auto-tune: Static
Auto-tune: Rotating
5
Analogue Input Control
Relay Control
Variable Selector
Temperature Monitoring
General
Diagnostics
Energy Meter
DIMENSIONS
Commander C200/C300 Dimentions
Frame Size mm in mm in
mm in kg lb
H W D H W D H W H W
1 160 75 130 6.30 2.95 5.1 143 53 5.7 2.08 5.0 0.20 0.75 1.65
2 205 75 150 8.07 2.95 5.9 194 55 7.63 2.17 5.0 0.20 1.3 3.0
3 226 90 160 8.90 3.54 6.3 315 70.7 8.46 2.80 5.0 0.20 1.5 3.3
4 277 115 175 10.90 4.50 6.9 265 86 10.43 3.40 6.0 0.23 3.13 6.9
5 391 143 200 15.39 5.63 7.87 375 106 14.76 4.17 6.5 0.26 7.4 16.3
6 291 210 227 15.39 8.27 8.94 378 196 14.88 7.72 7.0 0.28 14.0 30.9
7 557 270 280 21.93 10.63 11.02 538 220 21.18 8.66 9.0 0.35 28.0 61.7
8 804 310 290 31.65 12.21 11.42 884 259 30.87 10.20 9.0 0.35 52.0 114.6
9A 1069 310 290 42.09 12.21 11.42 1051 259 41.38 10.20 9.0 0.35 46.0 101.4
9E 1108 310 290 43.62 12.21 11.42 1090 259 42.91 10.20 9.0 0.35 66.5 146.6
7
WWW.CONTROLTECHNIQUES.COM
CONNECTIONS
PRODUCT CODES
C200- 03 4 00073 A - 101 00 AB100
Model: Frame Size Current Rating: CT Reserved Product Variant:
C200 – The lead product for 1 to 9
Commander C range Heavy Duty current rating x 10
AB100- Standard
C300 – As C200 + dual STO
8
WWW.CONTROLTECHNIQUES.COM
C200-04200176A10100AB100 3 04 17.6 4 5
C200-06200330A10100AB100 3 06 33 7.5 10 50 11 15
C200-06200440A10100AB100 3 06 44 11 15 58 15 20
C200-07200610A10100AB100 3 07 61 15 20 75 18.5 25
C200-07200750A10100AB100 3 07 75 18.5 25 94 22 30
C200-07200830A10100AB100 3 07 83 22 30 117 30 40
C200-03400073A10100AB100 3 03 7.3 3 3
C200-03400094A10100AB100 3 03 9.4 4 5
9
C200-04400135A10100AB100 3 04 13.5 5.5 7.5
C200-04400170A10100AB100 3 04 17 7.5 10
C200-05400270A10100AB100 3 05 27 11 20 30 15 20
C200-05400300A10100AB100 3 05 30 15 20 30 15 20
C200-06400350A10100AB100 3 06 35 15 25 38 18.5 25
C200-06400420A10100AB100 3 06 42 18.5 30 48 22 30
C200-06400470A10100AB100 3 06 47 22 30 63 30 40
C200-07400660A10100AB100 3 07 66 30 50 79 37 50
C200-07400770A10100AB100 3 07 77 37 60 94 45 60
C200-06500150A10100AB100 3 06 15 7.5 10 17 11 15
C200-06500190A10100AB100 3 06 19 11 15 22 15 20
C200-06500230A10100AB100 3 06 23 15 20 27 18.5 25
C200-06500290A10100AB100 3 06 29 18.5 25 34 22 30
C200-06500350A10100AB100 3 06 35 22 30 43 30 40
C200-07500440A10100AB100 3 07 44 30 40 53 37 50
C200-07500550A10100AB100 3 07 55 37 50 73 45 60
C200-08500630A10100AB100 3 08 63 45 60 86 55 75
C200-07600240A10100AB100 3 07 24 18.5 25 30 22 30
C200-07600290A10100AB100 3 07 29 22 30 36 30 40
C200-07600380A10100AB100 3 07 38 30 40 46 37 50
C200-07600440A10100AB100 3 07 44 37 50 52 45 60
C200-07600540A10100AB100 3 07 54 45 60 73 55 75
C200-08600630A10100AB100 3 08 63 55 75 86 75 100
Note: The listed ordering codes are for C200, 50 Hz default setting.
For C300 change the model digits (C200-xxxxxxxxxxxxxxxxxxx) from C200 to C300.
For 60 Hz change the Regional Default Setting digits (xxxx-xxxxxxxxxxxx00xxxxx) from 00 to 01.
© 2021 Nidec Control Techniques Limited. The information contained in this brochure is for guidance only and does not form part of any contract. The accuracy cannot be
guaranteed as Nidec Control Techniques Ltd have an ongoing process of development and reserve the right to change the specification of their products without notice.
Nidec Control Techniques Limited. Registered Office: The Gro, Newtown, Powys SY16 3BE. Registered in England and Wales. Company Reg. No. 01236886
Part No. 0781-0750-01 10/21