X-Roc Multibond LX: Multi-Purpose Primer and Mortar Additive
X-Roc Multibond LX: Multi-Purpose Primer and Mortar Additive
X-Roc MultiBond LX
Multi-purpose primer and mortar additive.
Mortars
Concrete repair mortar
Thickness is dependent on application but 15mm is normal.
50kg Type 1 Portland cement
On vertical surfaces this is built up in two applications.
125 kg Washed sharp sand (medium grading)
24 liters X-Roc MultiBond LX
Normal time between applications is 5 hours but this is
Yield 90 liters (approximate)
dependent on temperature.
Where more than one coat is applied ensure that the
Fairing coat intermediate coats are cross hatched to provide a mechanical
50kg Type 1 Portland cement key. If the surface dries out completely then the surface
100 kg Fine sand should be re-primed.
23 liters X-Roc MultiBond LX
Yield 80 liters (approximate)
Edition 4.2018
Version 1.2013
Renders Datasheet Validity
Two priming coats should be applied ideally at right NCC X-Calibur makes modifications to its product
angles to one another. The second coat should be applied datasheets on a continuous basis. Please check the
immediately after the first coat has dried, approximately datasheet update section on www.ncc.com.eg to ensure
30 minutes. Apply general purpose mortar while the you have the latest version.
primer is still tacky. Minimum thickness is 10mm. Where
more than one layer is applied, ensure that the Warranties
intermediate layers are hatched to provide a mechanical NCC X-Calibur supplies products that comply with the
key. If the surface dries out completely then the surface properties shown on the current datasheets. In the unlikely
should be re-primed. Allow 5 hours between layers. event that products supplied are proved not to comply with
these properties, then we will replace the non-compliant
Screeds product or refund the purchase price.
Apply up to 75mm in one application; the minimum NCC X-Calibur does not warrant or guarantee the
screed thickness should be 25mm. Ensure that the screed installation of the products as it does not have control over
is well bonded to the substrate and that it is fully the installation or end use of the products. Any suspected
compacted. Do not use water to finish the surface as this defects must be reported to X-Calibur in writing within five
will cause cracking, crazing and dusting of the surface. working days of being detected. NCC X-Calibur Construction
Chemistry Inc. makes no warranty as to
Curing merchantability or fitness for a particular purpose
Cure for a minimum of three days using a curing and this warranty is in lieu of all other warranties
compound or water. The longer the curing period (up to express or implied. NCC X-Calibur Construction Chemistry
seven days) the better will be the performance of the Inc. shall not be liable for damages of any sort including
mortar. Screeds should be continuously water cured for
remote or consequential damages, down time, or delay.
seven days.
Limitations
Do not allow to dry before applying mortar (when being
used as a primer).
Do not discard into the water system.
Avoid excessive application,
Avoid skin contact,
Quality Statement
All Products manufactured by NCC X-CALIBUR or imported from X-CALIBUR companies world-wide are
manufactured to procedures certified to conform the quality, environment, systems described in the
ISO 14001:2004. ISO 9001:2000.