Fiber Optic Light Cables: Innovative Technology From KARL STORZ, Bringing Light Into Darkness For 60 Years
Fiber Optic Light Cables: Innovative Technology From KARL STORZ, Bringing Light Into Darkness For 60 Years
The new 495 NCSC and 495 NAC cables have a safety lock to prevent accidental separation of the
light cable from the telescope. These are compatible with all endoscopes in the new telescope design
available from March 2012. Screw Base 495 G is required to connect all telescopes with the old design
and must be added to the order if the safety lock function should be implemented. 495 NCSC and 495
NAC are compatible with older telescopes without the lock function.
Recommended combination*
Adaptor for connecting KARL STORZ fiber optic light cables with endoscopes and light sources from
other manufacturers, see page 8
Fiber Optic Light Cables
Innovative Technology from KARL STORZ,
Bringing Light into Darkness for 60 Years
KARL STORZ offers a wide range of fiber optic light cables and adaptors that are designed to
meet the high levels of light required for minimally invasive surgery.
High-quality Components
KARL STORZ uses extremely heat-resistant materials in the endoscopic optic connectors.
Consequently, the light cables can easily be used with high-performance Xenon lamps. A
double reinforced silicone coating offers effective protection against damage or wear and tear
and prolongs the service life of the cables. High-quality glass fibers, manufactured according
to the most stringent quality requirements, provide excellent light transmission. This prevents
shadow formation and loss of light in procedures that require high light intensity, such as
cruciate ligament reconstruction in arthroscopy or bladder inspection in urology. The powerful
KARL STORZ cables also enable the use of telescopes with small diameters like those used in
ENT and Gynecology.
495 NE Fiber Optic Light Cable, dia. 4.8 mm, length 300 cm
495 NB Fiber Optic Light Cable, dia. 4.8 mm, length 180 cm
495 ND Fiber Optic Light Cable, dia. 3.5 mm, length 300 cm
495 NA Fiber Optic Light Cable, dia. 3.5 mm, length 230 cm
495 NL Fiber Optic Light Cable, dia. 3.5 mm, length 180 cm
495 NTA Fiber Optic Light Cable, dia. 2.5 mm, length 230 cm
495 NT Fiber Optic Light Cable, dia. 2.5 mm, length 180 cm
Fiber Optic Light Cable with 90° Deflection to the Light Source
495 NWMS Fiber Optic Light Cable, with 90° deflection to the
cold light fountain, diameter 3.5 mm, length 230 cm
495 NTXS Fiber Optic Light Cable, with 90° deflection to the
cold light fountain, diameter 2.5 mm, length 230 cm
495 NWL
495 NTW Fiber Optic Light Cable, with 90° deflection
to the cold light fountain on the fountain side,
diameter 2.5 mm, length 180 cm
Adaptor for connecting KARL STORZ fiber optic light cables with endoscopes and light sources from
other manufacturers, see page 8
Fiber Optic Light Cables
for Cold Light Fountains
The given diameter is the diameter of the built-in glass fibers on the
instrument side.
495 NAS Fiber Optic Light Cable, dia. 3.5 mm, length 230 cm
495 NTAS Fiber Optic Light Cable, dia. 2.5 mm, length 230 cm
495 NAS
Adaptor for connecting KARL STORZ fiber optic light cables with endoscopes and light sources from
other manufacturers, see page 8
6 7
495 NVL Fiber Optic Light Cable, with 90° deflection to the
instrument, diameter 3.5 mm, length 300 cm
495 NV/NVL 495 NVC
495 NV Fiber Optic Light Cable, with 90° deflection to the
instrument, diameter 3.5 mm, length 230 cm
The new Fiber Optic Light Cable 495 NVC has a 90° deflection to the instrument and a very narrow
radius of curvature. This space-saving feature makes it easier for the physician to handle the light
cable at the endoscope and considerably enhances light management. Furthermore, a newly
designed connector on the instrument side ensures that the light cable is securely attached to the
endoscope.
The Fiber Optic Light Cable 495 NVC replaces the combination of the Light Adaptor 495 EW with
the light cables of the 495 series.
Adaptor for connecting KARL STORZ fiber optic light cables with endoscopes and light sources from
other manufacturers, see page 8
Adaptors
for Light Sources and Light Cables
HOPKINS® Telescopes with Adaptor Light Cable
universal connector for light cables 495 G KARL STORZ
495 GO Olympus/Winter & Ibe
Olympus/Winter & Ibe
with attached lens
495 F Wolf
Fix mounted ACMI
Zimmer
CF 495 T – – –
Pentax
LC – 495 D – –
CF 495 Q – – –
HSW
LC – 495 E 495 N 495 N
I 495 ST – – –
CF 495 PA – – –
I 495 X – – –
Richard Wolf CF 495 Q – – –
LC – 495 E 495 M –
495 S:
CF 495 S – – – The use of KARL STORZ
fiberscopes with integrated
Olympus/ fiber optic light cable and
KARL STORZ light cables
Winter & Ibe with non-graduated distal
LC with connection (diameter 7 mm)
– – 495 GO 495 GO requires an additional adaptor
attached lens 495 PWS to adaptor 495 S.
8 9
Adaptor Series
for HALOGEN and XENON Light Sources
SCB
300
175
75 S
0 tw
CB
B
B
0 SC
5 SC
OVA ®
OVA ®
0
100
P SC
ED 1
C SC
C/AF
A 15
N 25
00 S
N 10
OVA
N 17
ON N
ER L
ON N
NOV
ON 3
GHT
GHT
OGE
GHT
or
O
t
Adap
POW
XEN
XEN
XEN
XEN
D-LI
D-LI
D-LI
XEN
HAL
LED
LED
487 A l – – – – l l l l – – –
487 M l – – – – l l l l – – –
487 O l – – – – l l l l – – –
487 VE l – – – – – – – – l l l
487 P l – – – – l l l l – – –
487 U l – – – – l l l l – – –
487 UO l – – – – l l l l – – –
487 W l – – – – l l l l – – –
487 WI l – – – – l l l l – – –
487 Z l – – – – l l l l – – –
Adaptor for connecting KARL STORZ fiber optic light cables with endoscopes and light sources from
other manufacturers, see page 8
Fluid Light Cables
for Cold Light Fountains
In fluid light cables, light is not transmitted via glass fibers, but through a special fluid inside
the light cable. Fluid light cables are stiffer than fiber optic light cables, and also should not
be bent too much. However, the light transmitted in them is more intensive than when using
fiber optic light cables of comparable diameters. Fluid light cables are therefore preferred
for photodynamic diagnosis (PDD) in conjunction with KARL STORZ light sources from the
D-LIGHT series.
Please note:
The high light concentration at the end of the light cable causes heat to be generated in the
focal point. The end of the light cable should never be placed on the patient’s drape or skin as
long as the cold light fountain is turned on, since the light intensity could cause burns in the
patient or set the drape on fire.
Notes
It is recommended to check the suitability of the product for the intended procedure prior to use.
Email Name
I agree to my data being stored at KARL STORZ for this purpose. I can withdraw my consent at any time and without giving reasons by emailing KARL STORZ
at [email protected]. KARL STORZ will not make these data available to third parties.
KARL STORZ GmbH & Co. KG KARL STORZ Endoscopy-America, Inc.
Mittelstraße 8, 78532 Tuttlingen, Germany 2151 East Grand Avenue
Postbox 230, 78503 Tuttlingen, Germany El Segundo, CA 90245-5017, USA
96202014 TP 26-8 06/2014/EW-E