Final Set Calculation by Modified Hiley's Formula
Final Set Calculation by Modified Hiley's Formula
Final Set Table is prepared in accordance with PIL1.D390.8 of HKHA Specification Librarary 2018 and Code of Practice for Foundation 2017
For Q = 2000 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
- - - - - - - - - - - - - - - 50 50 50 50 50 50 50 50 50 50 46 41 36 31 26
10mm
For Q = 2200 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
- - - - - - - - - - - 50 50 50 50 50 50 50 50 50 50 49 44 39 34 29 - - - -
10mm
For Q = 2400 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
- - - - - - - - 50 50 50 50 50 50 50 50 50 50 49 44 39 34 29 - - - - - - -
10mm
For Q = 2600 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
- - - - - - 50 50 50 50 50 50 50 50 50 50 47 42 37 32 27 - - - - - - - - -
10mm
For Q = 2800 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
- - - - 50 50 50 50 50 50 50 50 50 50 47 42 37 32 27 - - - - - - - - - - -
10mm
For Q = 3000 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
- - 50 50 50 50 50 50 50 50 50 50 48 43 38 33 28 - - - - - - - - - - - - -
10mm
Final Set Calculation By Modified Hiley's Formula
Final Set Table is prepared in accordance with PIL1.D390.8 of HKHA Specification Librarary 2018 and Code of Practice for Foundation 2017
For Q = 2000 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
- - - - - - - - - - 50 50 50 50 50 50 50 50 50 50 47 42 37 32 27 - - - - -
10mm
For Q = 2200 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
- - - - - - - 50 50 50 50 50 50 50 50 50 50 47 42 37 32 27 - - - - - - - -
10mm
For Q = 2400 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
- - - - 50 50 50 50 50 50 50 50 50 50 50 45 40 35 30 - - - - - - - - - - -
10mm
For Q = 2600 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
- - 50 50 50 50 50 50 50 50 50 50 49 44 39 34 29 - - - - - - - - - - - - -
10mm
For Q = 2800 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
- 50 50 50 50 50 50 50 50 50 50 45 40 35 30 25 - - - - - - - - - - - - - -
10mm
For Q = 3000 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
50 50 50 50 50 50 50 50 50 47 42 37 32 27 - - - - - - - - - - - - - - - -
10mm
Final Set Calculation By Modified Hiley's Formula
Final Set Table is prepared in accordance with PIL1.D390.8 of HKHA Specification Librarary 2018 and Code of Practice for Foundation 2017
For Q = 2000 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
- - - - - 50 50 50 50 50 50 50 50 50 50 49 44 39 34 29 - - - - - - - - - -
10mm
For Q = 2200 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
- - - 50 50 50 50 50 50 50 50 50 50 46 41 36 31 26 - - - - - - - - - - - -
10mm
For Q = 2400 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
- 50 50 50 50 50 50 50 50 50 50 45 40 35 30 25 - - - - - - - - - - - - - -
10mm
For Q = 2600 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
50 50 50 50 50 50 50 50 50 46 41 36 31 26 - - - - - - - - - - - - - - - -
10mm
For Q = 2800 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
50 50 50 50 50 50 50 48 43 38 33 28 - - - - - - - - - - - - - - - - - -
10mm
For Q = 3000 kN
cp + cq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set per
50 50 50 50 50 50 47 42 37 32 27 - - - - - - - - - - - - - - - - - - -
10mm