0% found this document useful (0 votes)
787 views2 pages

CENTER 337 Light Meter Instruction Manual

This document provides instructions for operating a light meter. It describes the device's safety information, general description, name and functions of buttons, and specifications. The light meter measures light levels in units of foot-candles and lux, has automatic and manual range selection, and an auto-power-off function. It is powered by a single 9V battery and has a measurement range from 4 to 40,000 lux or foot-candles.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
787 views2 pages

CENTER 337 Light Meter Instruction Manual

This document provides instructions for operating a light meter. It describes the device's safety information, general description, name and functions of buttons, and specifications. The light meter measures light levels in units of foot-candles and lux, has automatic and manual range selection, and an auto-power-off function. It is powered by a single 9V battery and has a measurement range from 4 to 40,000 lux or foot-candles.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

337

MINI LIGHT METER

337
LIGHTMETER

4 00

CAL

HOLD

fc lx

RANGE :

POWER-UP OPTIONS
HOLD

CENTER TECHNOLOGY CORP. Ver.00


4/F NO. 415,Jung-Jeng Rd.,238 Shu-Lin, Taipei, Taiwan
TEL : 886-2-26763926 E-Mail : [email protected]
FAX : 886-2-26763925 http : / / www.centertek.com
I. Safety Information Storage temp./humidity: During the measuring mode, press CAL button and the If appears, check the cap to make sure it is on
Read the following safety information carefully before -10℃ ~ 50℃(14℉ ~ 122℉),0 ~ 70﹪RH value of zero will be auto-displayed. properly.
attempting to operate or service the meter. Over range:"----" display 6 HOLD button :
○ Press and hold the HOLD button, and then power on the meter,
Use the meter only as specified in this manual; otherwise, Power supply : The user may hold the present reading and keep it on the release all button to disable the AUTO POWER OFF function.
the protection provided by the meter may be impaired. one 9V battery,006P or IEC 6F22 or NEDA 1604 LCD display by pressing the “HOLD” button. To release the “ ”symbol will disappear on the LCD display.
± Environment Conditions Power life:Approx. 170 hours (Alkaline battery) held data operation by pressing it again. The user can
… Altitude up to 2000 meters Dimensions: press the button when the value is hard to read, such as
196(L) ×54(W) ×33(H) mm measuring in the dark place.
† Relative humidity 90% max. VI、Replacement of battery:
7.7(L) X 2.1(W) X 1.3(H) inch 7 fc/lx selector button

‡ Operation Ambient 0 to 40℃ When the battery voltage drops below the operating voltage ,
Weight:Approx. 180g 8 Range selector button :

± Maintenance & Clearing a“ “ symbol will appear on the LCD display. In this
Accessories:9V battery , instruction manual This button is used to select automatic range and manual
… Repairs or servicing not covered in this manual should case, replace a new battery immediately.
range. Manual range enables an arbitrarily four range to be
only be performed by qualified personnel.
set. If a fixed range is used, measuring values will
† Periodically wipe the case with a dry cloth. Do not use
abrasives or solvents on this instrument.
IV、Name and functions: response quickly. The user can read easily.
VII、Characteristics of relative
The range configuration is as follows:
± Safety symbols
Auto , 40 , 400 , 4000 , 40000 lx
visible-spectrum response:
Comply with EMC Auto , 4 , 40 , 400 , 4000 fc
1 2
○9 Battery cabinet cover
When servicing, use only specified replacement Spectral Sensitivity
10 Indicate low battery voltage
CIE Photopic Curve Light Meter

parts. 100%
11 Measuring readout

Relative Sensitivity
LIGHTMETER

12 Indicate automatic range mode


○ 80
3 9V BAT TERY

13 Indicate meter in automatic power off mode



NEDA 1604 6F22 006P
4 00

60
II、General Description: 4
This Light Meter provides an automatic power-off function
Thank you for using our Light Meter. To ensure that you can 5 CAL in order to avoid using up the battery if you forget to turn 40

get the most from it, we recommend that you read and 6 HOLD off the power. The meter will power off itself after 30
20
follow the manual carefully before use. The Light Meter has 7 fc lx
OPEN
minutes if no key is operated.
been designed, manufactured, and delivered under strict 8 9 14 Indicate data hold
○ 0
RANGE :
400 500 600 700 800
quality control criteria by a factory certified. 15 Unit of illuminance

Wavelength(nm)
Easy to use 16 Indicate range

POWER-UP OPTIONS
HOLD

Automatic zero Note:1fc=10.76lx


Automatic range

13 ○
14 VIII、Precautions on handling:
Operating carefully, and do not drop the meter or hit it with a

10 V、Operation:
III、Specifications Press the power button to turn on the power. Notice that
hard object. Avoid using the meter in a dirty, dusty, or salt-air
Measuring ranges: ○
11

15 area or where there are corrosive gases. If dirt or dust
covering the light-detecting surface with the cap.. will
0.00 to 39.99/399.9/3999/39990 lx adhered to the surface of detecting light, will decrease

12 4 0000
auto-appear on the LCD display. After appears, the
0.000 to 3.999/39.99/399.9/3999 fc accuracy of the measuring value. To clean the surface by
meter enters the automatic zero adjustment. When automatic
automatic/manual selection of range wiping with a soft and dry cloth.

16 ○
16 zero adjustment is completed, disappears and “0.00 ”
Resolution : 0.01 lx ~ 10 lx ; 0.001 fc ~ 1 fc appears. After confirming the “0.00 ” display, remove the cap
Accuracy:±3﹪rdg ±5 dgts

1 Light detecting surface to start measuring.
Temperature characteristics:±0.1﹪/℃

2 Protect cover After the measurement has been completed, press the power
Response time:0.5 sec.

3 LCD display button again to turn off the power, and cover the light-detecting
Light detector:Si Photodiode

4 Power button surface with the cap for protecting against stray light.
Operation temp./humidity:

5 CAL button : Quick enter measuring mode Note :
0℃ ~ 40℃(32℉ ~ 104℉),0 ~ 80﹪RH

You might also like