0% found this document useful (0 votes)
415 views156 pages

Laboratory Atharva Laboratories Pvt. LTD., B-100, Phase-II, Noida, Uttar Pradesh

This document provides information on the biological testing capabilities of Atharva Laboratories Pvt. Ltd. at two locations in Noida, India. It lists the specific biological and microbiological tests the laboratory is accredited to perform on various products, including foods, beverages, water, and other agricultural and dairy products. Tests include those for detecting coliforms, E. coli, salmonella, yeast and mould counts, and total plate counts. Methods are in accordance with standards from the Indian Standards Institution. The scope of accreditation covers testing of microbiological contamination in foods and water samples.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
415 views156 pages

Laboratory Atharva Laboratories Pvt. LTD., B-100, Phase-II, Noida, Uttar Pradesh

This document provides information on the biological testing capabilities of Atharva Laboratories Pvt. Ltd. at two locations in Noida, India. It lists the specific biological and microbiological tests the laboratory is accredited to perform on various products, including foods, beverages, water, and other agricultural and dairy products. Tests include those for detecting coliforms, E. coli, salmonella, yeast and mould counts, and total plate counts. Methods are in accordance with standards from the Indian Standards Institution. The scope of accreditation covers testing of microbiological contamination in foods and water samples.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 156

Laboratory Atharva Laboratories Pvt. Ltd.

, B-100, Phase-II, Noida, Uttar Pradesh


Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 1 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed

BIOLOGICAL TESTING

LOCATION-1

I. FOOD AND AGRICULTURAL PRODUCTS

1. Beverages: Coliform IS 5401 (Part-1) ≥10 cfu/ml


Soft Drink, Fruit, TPC IS 5402 ≥10 cfu/ml
Juice Yeast & Mould IS 5403 ≥10 cfu/ml
Concentrate, Fruit
Beer
2. Bakery & conf. TPC IS 5402 ≥10 cfu/g
products: Coliform IS 5401 ≥10 cfu/g
Biscuits, Bread E-Coli IS 5887 P/A per 25g
Hard boiled sugar Salmonella IS 5887 P/A per 25g
Yeast & Mould Count IS 5403 ≥10 cfu/g
Shigella IS 5887 P/A per 25g
3. Stimulant foods E-Coli IS 5887 P/A per 25g
(Tea, Coffee, coca S. aureus IS 5887 P/A per 25g
products) Salmonella IS 5887 P/A per 25g
4. Fruit , Vegetable E-Coli IS 5887 P/A per 25g
and Their Salmonella IS 5887 P/A per 25g
products Shigella IS 5887 P/A per 25g
Fruit , Vegetable TPC IS 5402 ≥10 cfu/g
and Their Coliform IS 5401 (Part-1) ≥10 cfu/g
products Yeast & mould IS 5403 ≥10 cfu/g
5. Milk & Dairy E-Coli IS 5887: (Part-1) P/A per 25g
Products Salmonella IS 5887 (Part-3) P/A per 25g
(Milk: sterilized, TPC IS 5402 ≥10 cfu/g
flavored, Coliform IS 5401 (Part-1) ≥10 cfu/g
pasteurized, Yeast & mould IS 5403 ≥10 cfu/g

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 2 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
condensed, S. aureus IS 5887 (Part-2) P/A per 25g
Sweetened) Shigella IS 5887 (Part-7) P/A per 25g
cream, butter,
Skimmed Milk
powder
6. Sugar & sugar Total Plate Count IS 5402 ≥10 cfu/g
products Yeast & Mould Count IS 5403 ≥10 cfu/g
7. Gelatin & other Total Plate Count IS 5402 ≥10 cfu/g
gums
8. Cereals, pulses E-Coli IS 5887:(Part-1) P/A per 25g
and cereal Salmonella IS 5887 (Part-3) P/A per 25g
products: Shigella IS 5887 (Part-7) P/A per 25g
Maize, Maida, TPC IS 5402 ≥10 cfu/g
Soya Flour, Malt Coliform IS 5401:2012 (Part-1) ≥10 cfu/g
Extract Wheat Yeast & mould IS 5403 ≥10 cfu/g
Flour & Blends
9. Infant Food Coliform Count IS 5401( P-1) ≥10 cfu/g
Infant/ Milk Cereal
Based Weaning
Food
10. Canned & Yeast & Mould Count IS 5403 ≥10 cfu/g
Processed Foods Total Plate Count IS 5402 ≥10 cfu/g
Coliform Count IS 5401(Part-1 ) ≥10 cfu/g
11. Nut & Nut Salmonella IS 5887(Part-3) P/A per 25g
Products Shigella IS 5887 (Part-7) P/A per 25g
S. aureus IS 5887 (Part-2) P/A per 25g
II. WATER

1. Water Coliform IS 5401(Part-1)/ P/A per 250ml


(Drinking, Mineral, IS 1622 2 to 5300
Process, Natural, MPN/100ml
Packaged Drinking, E-Coli IS 1622/ P/A per 100ml
Irrigation, IS 5887 (Part-1) 2 to 5300

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 3 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Swimming Pool, MPN/100ml
Ice Manufacture) P/A per 250ml
Salmonella IS 5887(Part-3),/ IS: 15186 P/A per 250ml
Shigella IS 5887(Part-7) P/A per 250ml
Yeast & Mould Count IS 5403 P/A per 250ml
Aerobic Microbial Count IS 5402 ≥1 cfu/ml
(At 22 ºC)
Aerobic Microbial Count IS 5402 ≥1 cfu/ml
(At 37 ºC)
Faecal streptococci IS 5887(Part-2)/IS: 15186 P/A per 250ml
Staphylococcus aureus IS 5887(Part-2) P/A per 250ml
Vibrio cholera IS 5887(Part-5) P/A per 250ml
Vibrio parahaemolyticus IS 5887(Part-5) P/A per 250ml
Sulphite Reducing IS 13428 P/A per 50ml
anaerobes Annex-C
Pseudomonas IS 13428 P/A per 250ml
aeruginosa Annex-D
Standard Plate Count IS 1622 ≥1 cfu/ml
NOTE: The Laboratory has demonstrated competence for the stated scope for WATER. This however
does not fully cover the specification requirements of BIS for the Packaged Drinking Water as per IS:14543 and
the Packaged Natural Mineral Water IS:13428.

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 4 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed

CHEMICAL TESTING

I. FOOD & AGRICULTURAL PRODUCTS

1. Bakery products Moisture IS 12711 0.2% to 40%


1) Biscuit Determination of total IS 12711 1% to 90%
2) Bread solid content
3) Cake Protein content IS 6287 1% to 30%
Carbohydrate IS 1656 05% to 60%
Energy value USD/Agri/74 10 to1000 Kcal/100g
Fat IS 12711 1% to 60%
Acidity of Extracted Fat IS 12711 0.05% to 2%
Alcoholic Acidity IS: 6287 0.05% to 5%
Ash IS 12711 0.1% to 10%
Sugar IS 6287 0.1% to 30%
Acid Insoluble ash IS 1011 0.1% to 5%
2. Spices and Curcumin content IS 10925 0.2% to 5%
condiments (only in Turmeric)
(Whole & Ground) Total ash IS 1797 0.1% to 8%
Turmeric, Acid insoluble ash IS 1797 0.1% to 2%
Coriander, Alcohol soluble extract IS 1797 2% to 15%
Cardamom, Cold Water soluble IS 1797 1% to 50%
Cumin, Fennel, Extract
Fenugreek, Non Volatile Ether IS 1797 1% to 25%
Saffron, Garam- Extract
Masala
Starch IS 4706 (part 2) 0.1% to 75%
3. Stimulant Food Acid insoluble ash IS 13857 0.1% to 3%
Tea
4. Oil & Fats Oils Moisture IS 548 (Part I) 0.1% to 5%
(Mustard, Corn, Peroxide Value IS 548 (Part I) 0.5% to 75% mEq/kg
Groundnut, Acid value IS 548 (Part I) 0.05 to 5

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 5 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Sunflower) & Free Fatty Acid IS 548 (Part I) 0.1% to 5%
Ghee Soybean, (As oleic acid)
Coconut, Olive Specific Gravity IS 548 (Part I) 0.860 to 0.968
5. Sugar and Sugar Reducing sugars IS 6287 1% to 80%
Boiled & Confect- Sucrose IS 6287 0.5% to 95%
ionery/ Toffees Sulphate ash IS 6287 0.1% to 5%
Jaggery, Refined
sugar, Cube sugar
6. Honey Moisture IS 4941 1% to 30%
Specific gravity at 27ºC IS 4941 1.25 to 1.55
Reducing sugars IS 4941 50% to 80%
Fructose/Glucose Ratio IS 4941 0.5 to 2
Sucrose IS 4941 0.2% to 20%
Ash IS 4941 0.1% to 10%
Acidity(as Formic acid) IS 4941 0.01% to 2%
7. Salt Moisture IS 253 0.1% to 10%
Sodium Chloride IS 253 50% to 99.5%
8. Infant food Moisture IS 16072 1% to 5%
Infant Milk Powder Carbohydrate IS 1656-2007/AOAC 986.25 0.5% to 60%
& Vitamin C (As ascorbic IS 5838:/ AOAC 3 to 600 mg/100g
Cereal based acid ) Meth.985.3318th Edition /
infant food AOAC 967.21, 19th ed.
Energy Value USDA Agriculture Handbook 10-1000 Kcal/100 gm
No.74/By Calculation
Protein IS 6287 1% to 30%
Ash IS 14433 0.1% to 10%
Fat IS 12711 0.5% to 25%
Phosphorus AOAC 986.24 18th Ed., / 10 mg/kg to 50000
AOAC 965.17, 19th ed. mg/kg
Calcium (As Ca) IS 1797 10 to 1000 mg/100g
Iron (As Fe) IS 14433 1.0 to 500
mg/100g

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 6 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Acid insoluble ash IS 14433 0.01% to 10%

9. Vegetable, Fruit & Total Ash IS 3500 0.1% to 5%


Their Products Acidity IS 13844 0.01% to 5%
(Tomato Ketchup, Vitamin C IS 5838 3 to 600 mg/100g
Mango chutney, (As ascorbic acid ) AOAC Method 985.33,18th
Fruit Juice) Edition,/
AOAC 967.21, 19th ed.
Preservatives such as IS 3500 10 mg/kg to 1000
benzoic acid mg/kg
10. Pulses and Cereals Moisture IS 1155/ 0.1% to 10%
Whole & ground / IS 1009
Cereals products Alcoholic acidity IS 1155/ 0.02% to 1%
(Fortified Atta,Rice, IS 1009
Wheat,Maize, Total Ash IS 1155 0.1% to 10%
Chickpea, Rajma, IS 1009
Bengalgram, Soya Acid Insoluble Ash IS 1155 0.01% to 10%
bean, Dals, Maida, IS 1009
Wheat flour, Corn Gluten IS 1009 7% to 15%
flour, Soya, flour,
Besan,Soya chunk,
Corn Flakes)
II. WATER

1. Drinking Water Colour IS:3025(Part 4) 1 to 20 Hazen


Odour IS:3025(Part 5) Qualitative
Total hardness IS 3025 (Part 21) 5 mg/l to 2000 mg/l
(as CaCO3)
Chloride (as Cl ) IS 3025(Part 32) 10 mg/l to 1000 mg/l
Turbidity IS 3025 (Part10) 0.1 NTU to 200 NTU
Alkalinity (as HCO3) IS 3025(Part-23) 10 mg/l to 1000 mg/l
Total Dissolved solids IS 3025(Part-16) 15 mg/l to 2000 mg/l
Nitrate (as NO-3 ) IS 3025 (Part 34) 1 mg/l to 100 mg/l

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 7 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Residual Free chlorine IS 3025(Part-26) 0.05 mg/l to 2 mg/l

Sulphate (as SO42-) APHA (20nd Ed.) 5 mg/l to 1000 mg/l


(4500- NO-3 B)
Fluoride (As F) IS 3025(Part-60) 0.1mg/kg to100
mg/kg
Conductivity APHA (2510B.) 1micro/cm to 2000
micro/cm
Boron (as B) IS 3025 (Part-57) 0.01 mg/kg to10 mg/kg
Ammonia (NH3) IS 3025 (Part-34) 0.3 mg/kg to100 mg/kg
Phenolic compound IS 3025 (Part-43) 0.001 mg/kg to10
mg/kg
Calcium (as Ca) APHA (22nd Ed.)(3111B) 1 mg/l to 200 mg/l
pH IS 3025 (Part 2) 1 to 12
Magnesium (as Mg) APHA (22nd Ed.)( 3111B) 0.1 mg/l to 100 mg/l
III. POLLUTION & ENVIRONMENT

1. Waste Water pH IS 3025 (Part-11) 1 to 12


BOD APHA (22nd Ed.)( 5210B) 5 mg/kg to 1000
mg/kg
COD APHA (22nd Ed.)( 5220B) 5 mg/kg to10000
mg/kg
TSS APHA (22nd Ed.)( 2540D) 5 mg/kg to 500
mg/kg
Oil and grease IS 3025-Part 39 1 mg/kg to 100
mg/kg
Phosphate (PO4) APHA (22ndEd.) (4500D) 0.5 mg/kg to 100
mg/kg
Silica (SiO2) APHA (22nd Ed.) (4500 SiO2C) 5 mg/kg to 100
mg/kg
Ammonia (NH3) IS 3025(Part-34) 5 mg/kg to 100
mg/kg

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 8 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed

Nitrate (as NO-3 ) IS 3025-(Part 34) 1 mg/l to 100 mg/l


Total Kjedhal Nitrogen IS 3025-(Part 34) 0.5 mg/kg to 100
(TKN ) mg/kg
Ammonical nitrogen IS 3025-(Part 34) 0.5 mg/kg to 100
mg/kg
IV. PAINTS AND SURFACE COATING

1. Paints & Enamel Drying Time IS 101 (Part 3/Sec I) Qualitative


Consistency IS 2932: 13 Table 2 Cl. B Qualitative
Colour IS 101 (Part 4/Sec II) Qualitative
Flexibility and Adhesion IS 101 (Part 5/Sec II) Qualitative
Gloss IS 101 (Part 4/Sec IV) 50 to 100
Fineness of Grind IS 101 (Part 3/Sec V) 5 to 90
Mass in kg/10 l IS 101 (Part 1/Sec VII) 5 to 20 kg/10 Liter
Volatile Matter IS 101 (Part 2/Sec II) 10% to 60%
Non-Volatile Matter IS 101 (Part 8/Sec II) 10% to 60%
Lead Restriction IS 101 (Part 8/Sec IV) 5% to 50%
Fastness to Light IS 101 Part 4 sec 3 Qualitative Test
2. Polishes Odour IS 1746 Qualitative
Colour IS 1746 Qualitative
Consistency IS 1746 Qualitative
Applicability IS 1746 Qualitative
Softening Point IS 1746 40 °C to 80 °C
pH IS 1746 4 to 12
Nonvolatile Matter IS 1746 10% to 50%
Ooze Test IS 1746 Qualitative
V. PLASTIC & RESINS

1. Plastics and Filler content ASTMD 2584 0 to 100%


plastics product / Identification of fibres IS 667, IS 10146, IS 10141 Qualitative
Rubber & Rubber Loss on ignition/ Ash ASTMD 2584 / ASTMD 5630 0 to 100%

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 9 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Products content /IS 199

Migration test IS 9845 0.1 mg/l to 60 mg/l


Water Absorption ASTMD 570 0.1% to 100%
Carbon Black Content/ IS 3400 part 22 0.1% to 30%
Chemical Analysis
(In rubber and rubber
products)
2. Heavy Metals Lead IEC-62321, IS 9833 1 mg/kg to150
mg/kg
Cadmium 0.5 mg/kg to150 mg/kg
Mercury 0.2 mg/kg to100 mg/kg
Chromium VI 0.2 mg/kg to100 mg/kg
Antimony 15 mg/kg to100
mg/kg
Nickel 0.3 mg/kg to100 mg/kg
Copper 0.2 mg/kg to100 mg/kg
VI. TEXTILE (WOVEN & NON WOVEN)

1. Textiles & Related Colour Fastness to ISO 105 C 10 Qualitative


Products washing IS 764 (Grade 1 to 5)
(Fiber, yarn, IS 765
Fabrics, IS 687
Garments) IS 3361
IS 3417
Colour fastness to dry IS 4802 Qualitative
cleaning (Grade 1 to 5)
Colour fastness to IS 766 Qualitative
Rubbing/Crocking ISO 105-X12 (Grade 1 to 5)
Colorfastness to IS 971 / ISO:105 E04 Qualitative
Perspiration AATCC TM15 (Grade 1 to 5)
Colour fastness to IS 688 Qualitative
Organic solvent (Grade 1 to 5)

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 10 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Colour Fastness to IS 767 Qualitative
Water ISO-105-N01 (Grade 1 to 5)
IS 2530, Cl.no.13
IS 690
Colour fastness to hot IS 689 Qualitative
Pressing ISO105-XII (Grade 1 to 5)
AATCC-133
Colour Fastness to Light IS 2454 Qualitative
AATCC-TM 16 (Grade 1 to 5)
ISO 105-B02
IS 15844
Colour fastness to dry IS 4636 Qualitative
heat (Grade 1 to 5)
Colour fastness to IS 762 Qualitative
bleaching IS 763 (Grade 1 to 5)
ISO105 N02
Dimension changes to IS 2977 0.5% to 30%
soaking in water IS 665
IS 9543
Shrinkage on washing IS 2977/ IS 1299 Upto 10%
Heat shrinkage App-B of 0.5% to 10%
IS 11815
IS 15844
Water soluble matter IS 3456 Upto 1%
Ash content IS 199, Cl. No. 6 Upto 10%
Moisture content IS 199, Cl. No. 4 0.1% to 30%
Identification IS 667 Cotton/Viscos
AATCC–TM 20 /Polyester/Polymide/
IS 3412 Wool/Acrylic/Silk/
IS 9896 Linen/Asbestos/
IS 2006 Polyvinyl derivatives/
IS 3522(Part-2) Glass fibre/
Olefins & Cellulose

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 11 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Fibre
Blend Composition IS 3416 2% to 100%
IS 2006
IS 667
IS 3462
AATCC 20 & 20A
Wettability IS 2349 Subjective
BS 4554
Scouring Loss IS 1383 0.5% to 5%
Colur difference E AATCC 173 Upto 60
AATCC EP 7
pH value IS 1390 2 to 12
VII. PAPER & PULP

1. Writing and pH IS 1060(part 1) ±0.02 at 8.27


Printing Paper Moisture content IS 1060(part 1) ±0.28 at 19.65%
Computer Paper Ash IS 1060(part 1) ±0.10 at 4.33%
VIII. LEATHER

A. Leather & Leather


Product
1. Leather and Chromium VI Content IS 15298 pt 1,2,3&4 0.1 ppm to 30 ppm
Leather Products ISO 20344
(Upper, Linning, pH Value IS 15298 pt 1,2,3&4 2 to 12
Tongue, Insole ISO 20344
and Insocks) JSS 1010
JSS 1097 App. ‘G’ JSS 9330-
01App. ‘A’ & ‘B’
IND/ME/951(PROV)App. C IS
2530
AATCC TM 81
ISO 3071
IS 1390

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 12 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Total Lead Content ASTM E 1645 2 mg/kg to 30
ASTM E 1613 mg/kg
Lead IS 12074 0.5 mg/kg to 30
mg/kg
Chromium IS 13319 0.5 mg/kg to 30
mg/kg

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 13 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed

ELECTRICAL TESTING

I. CABLES AND ACCESSORIES

1. Electrical cable Annealing test (for Table 1 5 kN to 10 kN,


copper) ( ii-a, iii-a-1 ) of LC 0.5N
IS 694 & IEC 60227 3% to 40%
Cl. No 15.1 of
IS 1554 ( Pt-1)
Cl. No.15.1 of
IS 7098 (Pt-1)
Cl. No 21.1 of
IS 9968 (Part 1)
Cl. No 12.1 of
IS 2465
Cl. No 10.1 of
IS 9857
Cl. 5.2 c) of
IS 8783 part 3
Cl. 9.1 a) of
IS 5950
IS10810 (Pt-1)
Tensile test (for Table 1(ii-b, iii-a-2) of 5 kN to10 kN,
Aluminium) IS 694 & LC 0.5N
IEC 60227 50 N/mm2 to 300
Cl. No.15.1 of N/mm2
IS 1554 (pt-1)
Cl. No 15.1 of
IS 7098 (Pt-1)
Cl. No 21.1 of
IS 9968 (Pt-1)
Cl. No 12.1 of
IS 2465

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 14 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Cl. No 10.1 of
IS 9857
Cl. 10.2 a) of
IS 14255
IS10810(Pt-2)
Wrapping test (for Table 1 Visual test
Aluminium) ( ii-c, iii-a-3) of
IS 694 & IEC 60227
Cl. 15.1 of
IS 1554 ( pt-1)
Cl. No.15.1 of
IS 7098 (Pt-1)
Cl. 21.1 of
IS 9968 (Pt-1)
Cl. 10.2 c) of
IS 14255
IS10810(Pt-3)
Conductor Resistance Table 1 ( ii-d, iii-a-4 ) of 0.96 mΩ to 10Ω,
test IS 694 & IEC 60227 LC 0.2μΩ
Cl. No.15.1 of 1μΩ to 199.9kΩ
IS 1554 ( part 1)
Cl. No 15.1 of
IS 7098 (Part 1)
Cl. No 21.1 of
IS 9968 ( Part 1)
Cl. No 12.1 of
IS 2465-
Cl. 9.1 b) of
IS 5950
Cl. No 10.1 of
IS 9857
Table 2- 1.1) of
IEC 60245
Cl. 10.2 e) of

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 15 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
IS 14255
IS10810 (Pt-5)
Thickness of insulation Table 1 (ii-e, iii-b) of 0.2 mm to 10 mm,
IS 694 & IEC 60227 LC 0.001 mm
Cl. No.15.1 of
IS 1554 ( pt-1)
Cl. No 15.1 of
IS 7098 (Pt-1)
Cl. No 21.1 of
IS 9968 (Pt-1)
Cl. No 12.1 of
IS 2465-
Cl. No 4.2 of
IS 8783 (Pt-3)
Cl. No 10.1 of
IS 9857
Table 2- 2.3) of
IEC 60245
Cl. 9.1 c) of
IS 5950
IS10810 (Pt-6)
Tensile strength & Table 1( ii-f, iii-c-1,d-1)of 5 N to 10 kN
Elongation at break IS 694&IEC 60227 LC 0.01N
Cl. No.15.1 of IS 1554 ( pt-1)
Cl. No 15.1 of
IS 7098 (Pt-1)
Cl. No 21.1 of
IS 9968 (Pt-1)
Cl. No 12.1 of
IS 2465
Cl. No 4.2 of
IS 8783 (Pt-3)
Cl. No 10.1 of
IS 9857

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 16 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Cl. 9.1 d-i) of
IS 5950
Table 2- 3.1) of
IEC 60245
IS10810 (Pt-7)

Loss of mass in air oven Table 1(iii-c-2,d-2) of 30 to 150oC,


IS 694 & IEC 60227 LC 1 ⁰C
Cl. No.15.1 of 0.1 to 220 g
IS 1554 (pt-1) LC 0.1 g
Cl. No 15.1 of
IS 7098 (Pt-1)
Cl. 9.1 d-iii) of
IS 5950
IS10810 (Pt-10)
Ageing in air oven Table 1(iii-c-3,d-3) of 30 to 150⁰C
IS 694 & IEC 60227 LC 1 ⁰C
Cl. No.15.1 of
IS 1554 ( pt -1)
Cl. No 15.1 of
IS 7098 (Pt-1)
Cl. No 21.1of
IS 9968(Pt-1)
Cl. 12.1 of
IS 2465-
Cl. No 10.1 of
IS 9857
Cl. 9.1 d-ii) of
IS 5950
Cl. No 10.1 c-ii) of
IS 14255
Cl. No 4.2 of
IS 8783 (Pt-3)
Table 2- 3.2) of

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 17 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
IEC 60245
IS10810 (Pt-11)
Shrinkage tests Table 1(iii-c-4,d-4) of 0.25 to 10%
IS 694 & IEC 60227 0.5 to 220mm
Cl. No.15.1 of LC 0.5 mm
IS 1554 ( pt-1) 30 to 300oC/
Cl. No.15.1 of 0.1⁰C
IS 7098 (Pt-1)
Cl. No 12.1 of IS 2465
Cl. No 10.1 c-iv) of
IS 14255
Cl. No 4.3 of IS 8783 (Pt-3)
Cl. 9.1 d-vi) of IS 5950
IS10810 (Pt-12)
Heat shock tests Table 1(iii-c-5,d-5) of Qualitative,
IS 694 & IEC 60227 60 to 150⁰C
Cl. No.15.1 of Mandrels
IS 1554 ( pt 1 ) 3.5 to 80mm
Cl. 15.1 of
IS 7098 (Pt 1)
Cl. No 12.1 of
IS 2465-
Cl. No 4.2 of
IS 8783 (Pt-3)
Cl. 9.1 d-v) of
IS 5950
IS10810 (Pt-14)
Hot deformation tests Table 1(iii-c-6,d-6) of 30 to 250⁰C
IS 694 & IEC 60227 LC 1 ºC
Cl. No.15.1 of
IS 1554 (Pt-1)
Cl. No.15.1 of
IS 7098 (Pt-1)
Cl. No 12.1 of

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 18 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
IS 2465-
Cl. No 4.3 of
IS 8783 (Pt 3)
Cl. 9.1 d-iv) of
IS 5950
IS 10810 (Pt-15)
Cold bend/ Table 1 ( iii-c-8-9) of Qualitative
Cold Impact Test IS 694 & IEC 60227 -45 to -5° C,
Cl. 15.4 of LC 0.1° C
IS 1554 (pt-1) Mandrels
Cl. 15.4 of 3.5 to 80 mm
IS 7098 (Pt-1)
Cl. 21 of IS 2465
IS 10810 (Pt-20 & 21)
Vicat Softening Point Cl. 10.1 d - iv) of 40 to 300⁰C,
Test IS 14255 LC 0.1°C
IS 10810 (Pt-22) 0.01 to 25 mm,
LC 0.01 mm
Melt Flow Index Test Cl. 10.1d ) ii ) of 40 to 350ºC,
IS 14255 LC 0.1°C
IS10810 (Pt-23) 0.15 g to 50 g
per 10 min
Hot set Test Cl. No 4.2 &5.2 of 30 to 250ºC
IS 8783 (Pt-3) LC 0.1° C
Cl. No.15.1 of
IS 7098 (Pt-1)
Cl. 21.1 of
IS 9968 (Pt-1)
Cl. No 10.1 of
IS 9857
Table 2- 3.3) of
IEC 60245
Cl. 10.1 of
IS 14255

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 19 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
IS 10810(Pt-30)
Oil resistance test Cl. No.21.1 of 30 to 150ºC
IS 9968 (Pt-1) LC 0.1° C
Cl. 10.1 of
IS 9857
IS 10810 (Pt-31)
Water Absorption Cl. No 4.3 of 30 to 250 ºC
(Gravimetric method) IS 8783 (Pt-3) LC 0.1° C
Cl. No.15.1 of
IS 7098 (Pt-1)
Cl. 10.1 of IS 14255
IS 10810 (Pt-33)
Insulation resistance test Table-1 (ii- g) of 0.4 to 20 GΩ
IS 694 & IEC 60227 100 to 650 V DC
Cl. 15.1of IS 1554 (Pt-1)
Cl. No 21.1 of
IS 9968 (Pt-1)
Cl. No 15.1 of IS 7098(Pt-1)
Cl. No 4.3 of IS 8783 (Pt 3)
Cl. 9.1f) of IS 5950
Cl. 10.1 of IS 14255
IS 10810(Pt- 43)
High voltage (water Table-1 (iii-e-1) of IS 694 & Qualitative
immersion AC/DC test) IEC 60227 0.5 to 10 kV AC
At Room Temperature Cl. 15.1 of IS 1554(Pt-1) 0.5 to 2 kV DC
Cl. 15.1 of IS 7098 (Pt-1)
Cl. 21.1 of IS 9968 (Pt-1)
Cl.12.1 of IS 2465
Cl. 10.1 of IS 14255
Cl. 4.3 of IS 8783 (Pt-3)
Table-2-1.2 of IEC 60245
Cl. 9.1 e) of IS 5950
IS 10810 (Pt-45)

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 20 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Flammability test Table-1 ( iii-c-10 ) of 50 to 600mm
IS 694 & IEC 60227 LC 0.5mm
Cl. No 15.1 of 1 to 1800 seconds
IS 7098 (Pt-1) LC 0.01 sec
Cl. No 15.1 of
IS 1554 (Pt-1)
Cl. No 21.1 of
IS 9968 (Pt-1)
Cl. 9.1 g) of IS 5950
Cl. 12.4 of IS 2465
IS10810 (Pt-53)
Static Flexibility Test Cl. 11.3 of IS 9857 30 to 1000 mm
IS10810 (Pt-54) LC 0.5 mm
Thermal stability Table-1 ( iii-d-7 ) of 30 to 250oC
IS 694 LC 0.1oC
Cl. 15.1 of 10 to 200 minute
IS 1554 (Pt-1) LC 1 second
Cl. 15.1 of
IS 7098 (Pt-1)
IS 10810 (Pt-60)
Additional ageing test Cl. 10.9 of IS 694 Qualitative
IEC 60227 30 to 200 ⁰C
LC 0.1 ⁰C
2. Armored Wire Dimension Cl. No 7 of IS 3975 3 to 25 mm,
IS 10810-36 LC 0.01mm
0.2 to 25mm,
LC 0.001mm
Tensile Strength & Cl. No 8.1 of 3 to 10 kN,
Elongation at break IS 3975 LC 0.1 N, 4 to 30%
IS 10810-37 0.2 to 150 mm,
LC 0.01 mm
Torsion test Cl. No 8.2 of 1 to 50000 turns
IS 3975 LC 1 turns

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 21 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
IS 10810-38
Wrapping and Adhesion Cl. No 8.3 of Qualitative
test IS 3975 Mandrel upto 80 mm
IS 10810-39
Uniformity of Zinc Cl. No 9.2 of Qualitative
coating IS 3975 0.5 to 20gm,
IS 10810-40 LC 1mg
Mass of zinc coating Cl. No 9.1 of 1 mg to 320 g
IS 3975 LC 1 mg
IS 10810-41
Resistivity Cl. No 8.4 of 1 mili Ω to 10Ω,
IS 3975 LC 0.02 µΩ
IS 10810-42
3. Aluminium Diameter of Aluminium & Cl. 12.2 of 0.05 to 25 mm
Conductors Galvanized steel wire IS 398 (Pt 1&2) LC 0.001 mm
Table 1,2 &3 of
IS 398 (Part 3)
Table 1 & 2 of
IS 398 (Part - 4)
Cl. 13.3 of
IS 398 (Part 5)
Aluminizing test Cl. 12.6 of 1 mg to 320 g
IS 398 (part 3) LC 1 mg
Breaking load Test Cl. 12.3 of 5 N to 20 kN
Before and after IS 398 (part 1) LC 0.1 N
stranding Cl. 13.3 of
IS 398 (part 2)
Cl. 12.2 of
IS 398(part 3)
Cl. 12.2 of
IS 398 (part 4)
Cl. 13.5 of
IS 398 (part-5)

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 22 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Ductility Test Cl. 13.4 of 1 to 50000 count
IS 398 (part 2) LC 1 count
Cl. No 12.3 of 5 N to 10 kN
IS 398 (part 3) LC 0.1 N
Cl. 13.6 of
IS 398 (part 5)
Wrapping Test Cl. 12.4 of Qualitative
IS 398 (part1) Mandrels 3.5 to 80
Cl. 13.5 of mm
IS 398 (part 2)
Cl. 12.4 of
IS 398 (part3)
Cl. No 13.5
IS 398 (part 5)
Resistance Test Cl. 12.5 of 1μΩ to 19.99 kΩ
at 20 ⁰C IS 398 (part 1) 0.2μΩ to 11 Ω,
Cl. 13.6 of LC 0.2 μΩ
IS 398 (part 2)
Cl. 12.5 of
IS 398 (part 3)
Cl. 12.4 of
IS 398 (part 4)
Cl. No 13.6 of
IS 398 (part 5)
Galvanizing Test Cl. No 13.7 of 1 mg to 320 g
IS 398 (part 2 ) LC 1 mg
Cl. 13.9 of
IS 398 (part 5)
II. WIRING ACCESSORIES

1. Switch, Dimensions Cl. 9 of IS 1293 Qualitative


Socket –Outlets IEC 60884 4 A to 32A Switches
and Plug Cl. 9 of IS 3854

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 23 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
IEC 60669
Rating Cl. No 6 of IS 1293 Qualitative
IEC 60884 4 A to 32A Switches
Cl. No 6 of IS 3854
IEC 60669
Classification Cl. No 7 of IS 1293 Qualitative,
IEC 60884 4 to 32A Switches
Cl. No 7 of IS 3854 Without shutter flush
IEC 60669 type
Marking Cl. No 8 of IS 1293 Qualitative
IEC 60884
Cl. No 8 of IS 3854
IEC 60669
Protection against Cl. No 10 of IS 1293 Qualitative,
electric shock IEC 60884 40 V to70 V,
Cl. No 10 of LC 0.01 V
IS 3854 IEC 60669
Provision for earthing Cl. No 11 of IS 1293 0.3 to 5.50 V,
IEC 60884 LC 0.01V
Cl. No 11 of IS 3854 25 to 30A, LC 0.1A
IEC 60669 0.3 to 15V, LC 0.01V
25 to 250 A,
LC 0.1 A
Terminals Cl. No 12 of IS 1293 Qualitative
IEC 60884 2 to 10mm,
Cl. No 12 of IS 3854 LC 0.01 mm
IEC 60669 30N to 100N
Construction Cl. No 13 of Visual
requirements of switch IS 3854
IEC 60669
Mechanism Cl. No 14 of Qualitative
IS 3854
IEC 60669

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 24 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Construction Cl. No 13 of Visual
requirements of Fixed IS 1293
socket outlet IEC 60884

Construction of plug and Cl. No 14 of Qualitative


portable socket outlets IS 1293 1 mm to 150 mm,
IEC 60884 LC 0.01 mm
1 mm to 25 mm,
LC 0.01 mm
Interlocked socket – Cl. No 15 of Visual
outlet IS 1293
IEC 60884
Resistance to Ageing Cl. No 16.1of Qualitative
IS 1293 30 to 250 ⁰C,
IEC 60884 LC 1 ⁰C
Cl. No 15.1 of
IS 3854
IEC 60669
Resistance to Humidity Cl. No 16.3 of Qualitative
IS 1293 20 to 98% LC 0.1%
IEC 60884 RH
Cl. No 15.3 of 15 to 40C LC 0.10C
IS 3854
IEC 60669
Insulation resistance Cl. No 17.1 of 2 MΩ to 500 MΩ at
IS 1293- 500 ± 50 V DC
Cl. 16.1 of
IS 3854
IEC 60669
Electric Strength Cl. No 17.2 & 17.3 of Qualitative
IS 1293 0.5 kV to 5 kV,
IEC 60884 LC 0.1 kV
Cl. 16.2 & 16.3 of

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 25 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
IS 3854
IEC 60669
Temperature rise test Cl. No 19 of 30 to 100⁰C LC 10C
IS 1293 1.5 A to 50 A,
IEC 60884 LC 0.01A
Cl. No 17 of
IS 3854
IEC 60669
Making and breaking Cl. No 20 of Qualitative,
capacity test IS 1293 2 A to 40A , LC0.1A,
IEC 60884 10 to 300 V, LC 0.1V
Cl. No 18 of
IS 3854
IEC 60669
Normal operation test Cl. No 21 of Qualitative
IS 1293 2A to 40 A, LC 0.1A,
IEC 60884 10 V to 300 V,
Cl. No 19.1 of LC 0.1V
IS 3854- IEC 60669
Normal operation by Cl. 19.2 of Qualitative
fluorescent lamp circuit IS 3854 2 A to 40 A, LC 0.1A,
IEC 60669 10 V to 300 V,
LC 0.1V
Operation of earthing Cl. 18 of Qualitative,
contact IS 1293 6 A to 30A, LC 0.01A
IEC 60884 0.5 kV to 5 kV,
LC 0.1 kV
Resistance to heat Cl. No 25 of 30 to 1500C
IS 1293 LC 0.10C
IEC 60884 0.2 to 10 mm,
Cl. 21 of LC 0.01mm
IS 3854
IEC 60669

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 26 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Mechanical strength Cl. No 24 of Qualitative,
Test IS 1293 0.2 N to 250 N
IEC 60884 0.1Nm to 1.2 Nm
Cl. No 20 of LC 0.01Nm
IS 3854 1 Nm to 6 Nm,
IEC 60669 LC 0.1 Nm
Screws, current- Cl. No 26 of Qualitative
carrying parts and IS 1293 IEC 60884 0.1Nm to 1.2 Nm
connections Cl. No 22 of LC 0.01Nm
IS 3854 1 Nm to 6 Nm,
IEC 60669 LC 0.1 Nm
Creepage distance, Cl. No 27 of 0.1 to 150mm
clearance distance IS 1293 LC 0.01mm
Except transient voltage IEC 60884
Cl. No 23 of
IS 3854
IEC 60669
Resistance to Tracking Cl. No 28.2 of Qualitative,
IS 1293 10 to 600/0.1 V
IEC 60884 0.5 to 6/ 0.001 A
Cl. No 24.2 of
IS 3854
IEC 60669
Resistance to insulating Cl. No 28.1 of Qualitative
Material to Abnormal IS 1293 960⁰C
heat and fire IEC 60884 LC 1⁰C
Cl. No 24.1 of IS 3854
IEC 60669

Resistance to rusting Cl. No 29 of Qualitative


IS 1293 IEC 60884 30 to 100⁰C,
Cl. No 25 of IS 3854 LC 0.1 ⁰C

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 27 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
IEC 60669 20 to 98% RH LC 0.1
Additional Test on pins Cl. 30 of Qualitative, 0.5N to
provided with insulating IS 1293 100 N
sleeves. IEC 60884 30 to 250 ⁰C,
LC 1 ⁰C
1 to 1800 sec.,
LC 0.01 sec.
Up to -45⁰C, LC0.1⁰C
2. Conduit for Checking of Dimensions Cl. 7 of Qualitative,
Electrical IS 9537-1 0.5 to 5mm
Installation of IS 9537-3
Insulating Material IS 14930-2
Bending test Cl. 9.2 of Qualitative,
IS 9537-1 16 to 63mm
IS 9537-3
IS 14930-2
3. Conduit Systems Collapse test Cl. 9.5 of Qualitative,
for Electrical IS 9537-1 16 to 25mm
Installations IS 9537-3 30 to 150⁰C,
IS 14930-2 LC 0.1 °C
Compression test Cl. 9.3 of Qualitative,
IS 9537-1 Conduit of 16 to
IS 9537-3 63mm
IS 14930-2 Caliper 0 to 150 mm,
LC 0.01 mm
Load 0.75kN to 5kN
Impact test Cl. 9.4 of Qualitative,
IS 9537 – 1 (-)15⁰C to 60⁰C
IS 9537 – 3 LC 0.1°C
IS 14930-2
Electrical Characteristics Cl. 12 of 2 kV AC
Electrical Strength IS 9537-1 LC 0.05 kV
Insulation Resistance IS 9537-3 1Ω to 2GΩ,

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 28 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
IS 14930-2 Up to 600 V DC
Resistance to burning Cl. 11 of 50 to 600 mm, LC
IS 9537-1 0.5 mm
IS 9537-3 1 to 60 sec,
IS 14930-2 LC 0.01 sec
Marking Cl. 6 of Visual inspection
IS 9537-1
IS 9537-3
IS 14930-2
Resistance to heat Cl. 10 of Up to 60 oC ,
IS 9537-1 LC 0.1 oC
IS 9537-3 Up to 0.2mm,5 mm,
IS 14930-2 LC 0.001 mm
III. BATTERIES

1. Secondary Cells & Insulation and wiring IS 16046: & Resistance :


Batteries (Nickel system) IEC 62133: Clause. 5.2 1 kΩ to 2000 MΩ;
Containing 500VDC
Alkaline or Other Low Rate Charging IS 16046: & Voltage:0.7V to 22 V
Non Acid (Nickel system) IEC 62133: Clause. 7.2.1
Electrolytes Current: 30mA to
10A
Vibration IS 16046: & Frequency: 5 to 100
(Nickel system) IEC 62133: Clause. 7.2.2 Hz
Acceleration 1 to 10g
Voltage:0.7V to 22 V

Current: 30mA to
10A Amplitude +25 to
-25 mm
Moulded case stress IS 16046: & Heat Oven Temp :
(Nickel system) IEC 62133: Clause. 7.2.3 Upto 250 °C
Voltage:0.7V to 22 V

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 29 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed

Current: 30mA to
10A
Temperature Cycling IS 16046: & Environmental
(Nickel system) IEC 62133: Clause. 7.2.4 Chamber
Temp:170°C to -40°C
Voltage:0.7V to 22 V

Current: 30mA to
10A

Incorrect Installation IS 16046: & Voltage:0.7V to 22 V


(Nickel system) IEC 62133: Clause. 7.3.1
Current: 30mA to
10A
Resistance:1Ω
External Short Circuit IS 16046: & Voltage:0.7V to 22 V
(Nickel system) IEC 62133: Clause. 7.3.2
Current: 30mA to
10A
Resistance:80±20mΩ
Free Fall IS 16046: & Length:1 Mtr
(Nickel system) IEC 62133: Clause. 7.3.3 Voltage:0.7V to 22 V

Current: 30mA to
10A
Mechanical Shock IS 16046: & Upto 175g
(Nickel system) IEC 62133: Clause. 7.3.4 Voltage:0.7V to 22 V

Current: 30 mA to 10
A
Thermal Abuse IS 16046: & Heat Oven Temp :
(Nickel system) IEC 62133: Clause. 7.3.5 Upto 250 °C

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 30 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Voltage:0.7V to 22 V

Current: 30mA to
10A
Crush IS 16046: & Upto 13KN±1KN
(Nickel system) IEC 62133: Clause. 7.3.6 Voltage:0.7V to 22 V

Current: 30mA to
10A
Low Pressure IS 16046: & Voltage:0.7 V to 22
(Nickel system) IEC 62133: Clause. 7.3.7 V
Current: 30mA to
10A
Temp:15°C to 50°C
Vacuum Oven
Pressure: Up to
11.6kPa
Overcharge IS 16046: & Voltage:0.7 V to 22
(Nickel system) IEC 62133: Clause. 7.3.8 V
Current: 30mA to
10A
Forced Discharge IS 16046: & Voltage:0.7 V to 22
(Nickel system) IEC 62133: Clause. 7.3.9 V
Current: 30mA to
10A
Charge (Procedure 2) IS 16046: & Voltage:0.7 V to 22
IEC 62133: Clause.8.1 V
Current: 30mA to
10A
Continuous Charge IS 16046: & Voltage:0.7 V to 22
IEC 62133: Clause.8.2.1 V
Current: 30mA to
10A

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 31 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Moulded case stress IS 16046: & Heat Oven Temp :
(Nickel system) IEC 62133: Clause. 8.2.2 Upto 250°C
Voltage:0.7V to 22 V

Current: 30mA to
10A
External short IS 16046: & Voltage:0.7V to 22 V
circuit(cell) IEC 62133: Clause. 8.3.1
Current: 30mA to
10A
Resistance:80±20mΩ
External short IS 16046: & Voltage:0.7V to 22 V
circuit(battery) IEC 62133: Clause. 8.3.2
Current: 30mA to
10A
Resistance:80±20mΩ
Free Fall IS 16046: & Length:1 Mtr
IEC 62133: Clause. 8.3.3 Voltage:0.7V to 22 V
Current: 30mA to 10A
Thermal Abuse IS 16046: & Heat Oven Temp
IEC 62133: Clause. 8.3.4 :Upto 250 °C
Voltage:0.7V to 22 V

Current: 30mA to
10A
Crush IS 16046: & Upto 13KN±1KN
IEC 62133: Clause. 8.3.5 Voltage:0.7V to 22 V

Current: 30mA to
10A
Overcharge IS 16046: & Voltage:0.7 V to 22
IEC 62133: Clause. 8.3.6 V
Current: 30mA to

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 32 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
10A
Forced Discharge IS 16046: & Voltage:0.7 V to 22
IEC 62133: Clause. 8.3.7 V
Current: 30mA to
10A
IV. SAFETY TEST FACILITY

1. Safety of Marking and Instruction IS 15644 : 2006 Qualitative


Electrical Toys IEC 62115: (2003)
Cl. No 7.0
Power Input Test IS 15644 : 2006 Voltage: 30.0 V to
IEC 62115: (2003) 300 V AC/ 0.1V, up
Cl. No. 8.0 to
30V DC /0.1V
Current: 0.01A to 10
A
Wattage: 0.0001 W
to 03 kW
Heating and abnormal IS 15644 : 2006 Voltage: upto
operation IEC 62115: (2003) 400/0.01 AC V.
Cl. No. 9.0 Current: 0.001A to 10
A
Wattage: 0.001 W to
03 kW
Temp: 25 ºC to 300
ºC
Electrical strength at IS 15644 : 2006 Voltage: 30.0 V to
operating temperature IEC 62115: (2003) 600 V AC/0.001V
Cl. No. 10.0 Time: 10 ms to 9000
s
Moisture Resistance IS 15644 : 2006 Temp: 20 ºC to 30 ºC
IEC 62115: (2003) RH : 90% to 96 %
Cl. No. 11.0 IPX4: 0.56 L/min to

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 33 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
7.0 L/min
Electrical strength at IS 15644 : 2006 Voltage: 30.0 V to
room temperature IEC 62115: (2003) 600 V AC/0.001V
Cl. No. 12.0 Time: 10 ms to 9000
s
Mechanical Strength IS 15644 : 2006 Impact Energy:
IEC 62115: (2003) 0.1 to 6 J.
Cl. No. 13.0
Construction IS 15644 : 2006 Dead weight: 1kg
IEC 62115: (2003) Force: 0.1 N to 500 N
Cl. No. 14.0 Time: 10 ms to 9000
(Excluding Cl. No. 14.15) s
Measurement
0.01 mm to150mm
Electronic weighing
scale:0.001kg to 50
kg
Voltage: up to
300/0.1V AC, upto
30/0.1 V DC
Current: 0.01A to 10
A
Wattage:0.0001W to
03 kW
Protection of Cords and IS 15644 : 2006 Measurement
Wire IEC 62115: (2003) 0.01mm to 150mm
Cl. No. 15.0
Screws and IS 15644 : 2006 Torque: 0.4 to 6 Nm
Connections, IEC 62115: (2003) Measurement
Cl. No. 17.0 0.01mm to150mm
Clearances and IS 15644 : 2006 Measurement
Creepage IEC 62115: (2003) 0.01mm to150mm
Cl. No. 18.0

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 34 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Resistance to Heat and IS 15644 : 2006 Distance: 0.01mm to
Fire IEC 62115: (2003) 300mm
Cl. No. 19.0 Temp: 1 to 1000 °C
for Glow Wire
Upto 250°C for Ball
Pressure.
timer upto 99.9 sec
Ball Pressure: Dia
2.5mm, 20N

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 35 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed

ELECTRONICS TESTING

LOCATION-1

I. DOMESTIC ELECTRONIC APPLIANCES & ACCESSORIES

1. Electronics Normal operating IS 616: Voltage: upto 300/0.1


Product (Audio, condition (Input power) Clause No: 4.2 AC V,
Video and Similar upto 30/0.1 V DC
Electronic Current: 0.01A to 10
Apparatus) A
Wattage:
0.0001 W to 03 kW
Marking & Instructions IS 616: Qualitative
Clause No: 5
Heating under normal IS 616: Temp: 25 ºC to 300
operating conditions Clause No: 7.1 ºC
Construction IS 616: Qualitative
requirement with regard Clause No: 8 Force:0.1 N to 1000
to the protection against N
electric shock
Determination of IS 616: Voltage: upto 300/0.1
hazardous live parts Clause No: 9.1.1 AC V,
up to 30/0.1 V DC
Current: 0.01A to10
A
0.005 mA to 10 mA
Force: 0.1 N to 100 N
Opening of enclosure IS 616: Qualitative
Clause No: 9.1.3
Terminals IS 616: Qualitative
Clause No: 9.1.4

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 36 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Pre-set control IS 616: Qualitative
Clause No: 9.1.5 Force: 0.1N to 500 N
Withdrawal of mains IS 616: 0.1 V to 300 VAC
plug Clause No: 9.1.6 Time : 1 µs to 10 s
Resistance to external IS 616: Force: 0.1 N to 500 N
forces Clause No: 9.1.7
Surge test Clause No. 10.1 Surge Voltage up to
10kV
50 discharge 12/min.
C1 = 1 nF R1 = 1 kΩ
Rs= 15MΩ
Humidity Test IS 616: Temp: 25 ºC to 50 ºC
Clause No: 10.2, 8.3 RH : 30 to 95%
Insulation Resistance IS 616: Resistance :
Clause No: 10.3.2 1 kΩ to 2000 MΩ;
500VDC
Dielectric Strength IS 616: High Voltage:0.1 kV
Clause No: 10.3.2 to 5 kV
Current: 0.1 kV to 6
kV DC
Tripping current:
upto 100 mA
Time: 10 ms to 9000
s
Leakage current under IS 616: 0.1 mA to10 mA
fault condition Clause No: 11.1
Heating test under fault IS 616: Temp: up to 200/ 0.1
condition Clause No: 11.2 ºC
Bump Test IS 616: Qualitative
Clause No: 12. 1.1 Distance:
0.01 mm to 300 mm
Vibration Test IS 616: Qualitative
Clause No: 12. 1.2 Frequency: 5 to 100

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 37 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Hz
Acceleration 1 to 10g
Amplitude 0.35mm
Impact Test IS 616: Qualitative
Clause No: 12.1.3 Impact Energy: 0, 5 J
, Spring hammer
mass up to 500gm
Ball Dia: (50 ± 1)
mm,
Drop Test IS 616: Qualitative
Clause No: 12.1.4 Scale : 0.001 m to1
m
Length: 0.01mm to
300 mm
Stress relief Test IS 616:Clause No: 12.1.5 Temp: up to 180/ 0.1
ºC
Fixing of actuating IS 616: Qualitative
elements Clause No: 12.2 Force: 0.1 N to 500 N
Torque: 0.1 to 6 Nm
Mass: 0.1kg to 50 kg
Time: 10 ms to 9000
s
Drawer IS 616: Qualitative
Clause No: 12.4 Force gauge: 0.1N to
500 N
Time: 10 ms to 9000
s
Telescoping or rod IS 616: Qualitative
antennas Clause No: 12.6
Clearance & Creepage IS 616: Voltage: 0.5V to 300
distances Clause No: 13.1 to Clause V
13.3.4a) & Cl.13.4 Force : 0.1 N to 500
N

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 38 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Length: 0.01mm to
300 mm
Impulse 1.2/50µS
upto 0.01kV to 10kV
Earth bond Test IS 616: Voltage 0.10 Volt to
Clause No: 15.2 14.24 V
Current 0.1 A to 300
A
External flexible cord IS 616: Force: 0.1 N to 500 N
Clause No: 16 Torque: Up to 6 Nm
Weight: 0 to 50 kg
Electric connection and IS 616: Qualitative
Mechanical Fixing Clause No: 17 Torque: 0.4 to 6 Nm
Micrometer: 0.001 to
25mm
Stability IS 616: Qualitative
Clause No: 19.1 to 19.3 Angle : 10 º
Length: 0.01 mm to
300 mm Force: 0.1 N
to 500 N
Wall or ceiling mounting IS 616: Qualitative
means Clause No: 19.6 Force: 0.1 N to 500 N
Weight: 0 to 50 kg
Resistance to fire (Glow Clause No: 20 Temp: 1 to 1000 ºC
wire) fro Glow Wire
Weight 1N, Distance
200mm

Resistance to fire Clause No: 20 Temp: 1 to 1000 ºC


(Needle flame) Flame height upto
12mm
Information Technology
Equipment

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 39 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Double or Reinforced IS 13252(part- Voltage DC :
Insulation Bridged by 1):2010+A1:2013+A2:2015/IE 0 to 30/0.1V
components C:60950- Resistance: 0 to 20
1:2005+A1:2009+A2:2013 kΩ
Clause No: 1.5.7.3, 2.4.2 Temp.: 25±10 °C to
40±2°C
Humidity upto 95%
RH
Input Test IS 13252(part- Voltage: AC:
1):2010+A1:2013+A2:2015/IE 0 to 300V
C:60950- Current: AC: 0.01A
1:2005+A1:2009+A2:2013 to10 A
Clause No: 1.6.2 Wattage: 0.1W to1
kW
Voltage: DC: 0 to
30/0.1 V
Current DC : 0.01 A
to10 A
Durability of Marking IS 13252 (part-1): Qualitative
Test 2010+A1:2013+A2:2015/IEC:6
0950-
1:2005+A1:2009+A2:2013
Clause No: 1.7.11
Access to Energized IS 13252(part- Qualitative
parts test 1):2010+A1:2013+A2:2015/IE Force:0.1 N to1000 N
C:60950- Test Pin 2B , Test
1:2005+A1:2009+A2:2013 finger fig 2A,Test
Clause No: 2.1.1.1 Prob Fig.2C.
Energy hazard IS 13252(part- Voltage: AC: 0 to
measurements 1):2010+A1:2013+A2:2015/IE 300V
C:60950- Current: AC: 0.01A
1:2005+A1:2009+A2:2013 to10 A
Clause No: 2.1.1.5 Wattage: 0.1W to1
kW

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 40 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Voltage: DC: 0 to
30/0.1 V
Current DC : up
to10/0.1 A
Capacitance discharge IS 13252(part- Voltage: 0.1 V to 300
test 1):2010+A1:2013+A2:2015/IE V
C:60950- Time : 1µs to 10 s
1:2005+A1:2009+A2:2013
Clause No: 2.1.1.7
SELV reliability test IS 13252(part- Voltage: 0 to 300 V
1):2010+A1:2013+A2:2015/IE Current: 0 to10/0.1 A
C:60950-
1:2005+A1:2009+A2:2013
Clause No: 2.2.2, 2.2.3, 2.2.4
TNV Circuits IS 13252(part- Voltage: 0 to 300 V
1):2010+A1:2013+A2:2015/IE Current: 0 to 10/0.1A
C:60950-
1:2005+A1:2009+A2:2013
Clause No: 2.3
Limited Current Circuit IS 13252(part- 0.1 mA to 99 mA
measurements 1):2010+A1:2013+A2:2015/IE
C:60950-
1:2005+A1:2009+A2:2013
Clause No: 2.4.1, 2.4.2
Limited power source IS 13252(part- Voltage: 0 to 1000V
measurements 1):2010+A1:2013+A2:2015/IE Current: 0 to 8A
C:60950-
1:2005+A1:2009+A2:2013
Clause No: 2.5
Earthing test IS 13252(part- Voltage 0.10 Volt to
1):2010+A1:2013+A2:2015/IE 14.24 V
C:60950- Current 0.1Amp to
1:2005+A1:2009+A2:2013 300 Amp

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 41 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Clause No: 2.6.3.4, 2.6.1
Humidity Test IS 13252(part- Temperature :
1):2010+A1:2013+A2:2015/IE Up to 55/0.1 °C
C:60950- RH : 10% to 95%
1:2005+A1:2009+A2:2013
Clause No: 2.9.2
Determination of working IS 13252(part- Voltage: 0.5V to 300
voltage/ Clearance and 1):2010+A1:2013+A2:2015/IE V
Creepage measurement C:60950- Force : 0.1 N to 500
1:2005+A1:2009+A2:2013 N
Clause No: 2.10.2, 2.10.3, Length: 0.01mm to
2.10.3.9a, 2.10.4 300 mm
Impulse 1.2/50µS
upto 0.01kV to 10kV
Steady force test IS 13252(part- Qualitative
1):2010+A1:2013+A2:2015/IE Force gauge:0.1N to
C:60950- 1000N
1:2005+A1:2009+A2:2013
Clause No: 4.2.2, 4.2.3, 4.2.4
Transformer / Insulation IS 13252(part- Qualitative
Electric strength test 1):2010+A1:2013+A2:2015/IE High Voltage:
C:60950- up to 10/0.1 kV AC
1:2005+A1:2009+A2:2013 up to 5/0.1 kV DC
Clause No: 2.10.5.2, 2.9.5 Tripping current:
0 to100 mA
Time: 10 ms to 9000
s
Enclosed or hermitically IS 13252(part- Qualitative
sealed unit test 1):2010+A1:2013+A2:2015/IE Temperature :
C:60950- Up to180/0.1 °C
1:2005+A1:2009+A2:2013 RH : 10% to 95%
Clause No: 2.10.7, 2.10.8
Strain relief test IS 13252(part- Qualitative

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 42 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
1):2010+A1:2013+A2:2015/IE Force gauge:0.1N to
C:60950- 1000N
1:2005+A1:2009+A2:2013
Clause No: 3.2.6,4.2.7
Cord guard test IS 13252(part- Qualitative
1):2010+A1:2013+A2:2015/IE Force gauge:0.1N to
C:60950- 1000N
1:2005+A1:2009+A2:2013
Clause No: 3.2.8
Supply wiring test IS 13252(part- Qualitative
1):2010+A1:2013+A2:2015/IE
C:60950-
1:2005+A1:2009+A2:2013
Clause No: 3.3.8, 3.2.9
Stability tests IS 13252(part- Qualitative
1):2010+A1:2013+A2:2015/IE Angle : 10°
C:60950- Force gauge:0.1N
1:2005+A1:2009+A2:2013 to1000N
Clause No: 4.1
Steady force tests IS 13252(part- Qualitative
1):2010+A1:2013+A2:2015/IE Force gauge:0.1N to
C:60950- 500 N
1:2005+A1:2009+A2:2013
Clause No: 4.2.1 - 4.2.4
Impact Test IS 13252(part- Qualitative
1):2010+A1:2013+A2:2015/IE Scale :0.001 m to 3
C:60950- m
1:2005+A1:2009+A2:2013 Mass: 500 g
Clause No:. 4.2.5 Ball Dia : (50 ± 1)mm
Vernier:0.01mm to
300 mm
Drop test IS 13252(part- Qualitative
1):2010+A1:2013+A2:2015/IE Scale : 0.001m to 3m

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 43 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
C:60950-
1:2005+A1:2009+A2:2013
Clause No: 4.2.6
Stress relief test IS 13252 (part-1):2010+ Temperature :
A1:2013+A2:2015/IEC:60950- 01 to 250 °C
1:2005+A1:2009+A2:2013
Clause No: 4.2.7
Wall or ceiling mounted IS 13252(part- Qualitative
equipment 1):2010+A1:2013+A2:2015/IE Weight:1 mg to 100
C:60950- kg
1:2005+A1:2009+A2:2013 Time: 10 ms to 9000
Clause No: 4.2.10 s
Sharp edge test IS 13252(part- Qualitative (Visual)
1):2010+A1:2013+A2:2015/IE
C:60950-
1:2005+A1:2009+A2:2013
Clause No: 4.3.1
Knobs / Handles Pull IS 13252(part- Qualitative
Loading Test 1):2010+A1:2013+A2:2015/IE Force gauge:0.1N to
C:60950- 500N
1:2005+A1:2009+A2:2013 Time: 10 ms to 9000
Clause No: 4.3.2 s
Connector current IS 13252(part- Qualitative
interruption test 1):2010+A1:2013+A2:2015/IE
C:60950-
1:2005+A1:2009+A2:2013
Clause No: 4.3.5
Dust, powder, liquids IS 13252(part- Qualitative
and gases 1):2010+A1:2013+A2:2015/IE
C:60950-
1:2005+A1:2009+A2:2013
Clause No: 4.3.10
Protection against IS 13252(part- Qualitative (Visual )

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 44 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
hazardous moving parts 1):2010+A1:2013+A2:2015/IE Force: 0.1 N to1000 N
test C:60950- Mass: 0.1 kg to 300 kg
1:2005+A1:2009+A2:2013
Clause No: 4.4
Heating test IS 13252(part- Temp: 0.01 °C to 200
1):2010+A1:2013+A2:2015/IE °C
C:60950-
1:2005+A1:2009+A2:2013
Clause No: 4.5
Touch Current Test IS 13252(part- 0.1 mV to 100V
1):2010+A1:2013+A2:2015/IE
C:60950-
1:2005+A1:2009+A2:2013
Clause No: 5.1
Electric Strength Test IS 13252(part- H. V.: 0.1 kV to 10 kV
1):2010+A1:2013+A2:2015/IE AC
C:60950- DC: 0.1 kV to 5/0.1
1:2005+A1:2009+A2:2013 kV
Clause No: 5.2 Tripping current:
0 to100 mA
Time: 10 ms to 9000 s
III. SAFETY TESTING FACILITY

1. Safety of House Marking and instruction IS 302-2-25


Hold and Similar (Clause. 7) Qualitative (Visual)
Electrical /IEC 60335-2-25
Appliances Protection against IS 302-2-25 Force:0.1 N to 1000 N
Part-2 Particular access to live parts (Clause. 8) Length: 0.01mm to
Requirements /IEC 60335-2-25 300 mm
Section 25 Test probes
Microwave Oven Voltage: Upto
60V/LC0.01V
Input Test IS 302-2-25 Voltage: AC: 0 to

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 45 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
(Clause. 10) / 300V
IEC 60335-2-25 Current: AC: 0.01A
to10 A
Wattage: 0.1W to 2
kW
Temperature Rise IS 302-2-25 Voltage: AC: 0 to
(Clause. 11) /IEC 60335-2-25 300V
Current: AC: 0.001A
to10 A
Wattage: 0.1W to1
kW
Temp:0.1oC to 300 oC
Electrical Strength and IS 302-2-25 H. V.: 0.1 kV to 10 kV
Leakage Current at (Clause. 13) / AC
Operating Temperature IEC 60335-2-25 DC: 0.1 kV to 5/0.1 kV
Tripping
current:10mA to 300
mA
Time: 10 ms to 9000
s Leakage Current:
upto 1µA to 500mA
Transient over Voltage IS 302-2-25 Impulse Voltage upto
(Clause. 14) / 300 volt to 10kV
IEC 60335-2-25 Rise time 1.2/fall time
50µs
Moisture Resistance IS 302-2-25 Temp: 25 ºC to 50 ºC
(Clause. 15) / RH : 30% to 95%
IEC 60335-2-25
Insulation Resistance IS 302-2-25 Resistance :
and Electrical Strength (Clause. 16) / 1 kΩ to 2000 MΩ;
(After Humidity IEC 60335-2-25 500VDC
Treatment) H. V.: 0.1 kV to 10 kV
AC

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 46 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
DC: 0.1 kV to 5/0.1
kV
Tripping current:0
to300mA
Time: 10 ms to 9000 s

Endurance Test IS 302-2-25 Total


(Clause. 18) /IEC 60335-2-25 operation:1,00000
Count
/LC 1 Count
Abnormal Operation IS 302-2-25 Current AC: 5 mA to
(Clause.19) /IEC 60335-2-25 20 A
Wattage: 0.1W to 1
kW
Temperature:
0.01°C to 200°C
Mechanical Strength IS 302-2-25 Angle : 0 to 90 °
(Clause.21) /IEC 60335-2-25 Force gauge: 0.1 N
to 1000 N
Construction IS 302-2-25 Force gauge: 0.1 N
(Clause.22) / to 1000 N
IEC 60335-2-25 Microwave Leakage:
100w/m2
Internal Wiring IS 302-2-25 Qualitative (Visual)
(Clause.23) /
IEC 60335-2-25
Components IS 302-2-25 Qualitative(Visual)
(Clause.24) /
IEC 60335-2-25
Cord Grip And Cord IS 302-2-25 i) H. V.: 0.1 kV to 10
Guard (Clause.25) / kV AC
IEC 60335-2-25 DC: 0.1 kV to 5/0.1
kV

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 47 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Tripping current: 0
to300 mA
ii) Measurement
0.01mm to 150mm.
iii) Resistance: 0.2µΩ
to 11Ω
iv) Load: Upto 1000 N.
v) Flexing: 1 count to
99999 counts
Provision For Earthing IS 302-2-25 (Clause 27) / Voltage 0.10 V to
IEC 60335-2-25: 14.24 V
Current 0.1A to 300 A
Screws And IS 302-2-25 (Clause 28) / Torque: 0.4 to 6 Nm
Connections IEC 60335-2-25
Creepage Distances and IS 302-2-25 i) Peak Voltage VAC:
Clearances (Clause 29) / 50mVp-p to 400 Vp-p
IEC 60335-2-25 ii) Length: 0.01 mm
to 300 mm
iii) Force:0.1 N to 500
N
iv) CTI: Up to
600V,10Amp,100
Count
Resistance to Heat and IS 302-2-25 Distance: 0.01mm to
fire (Clause 30) / IEC 60335-2-25 300mm
Temp: 1 to 1000 ºC
fro Glow Wire & upto
250 ºC for Ball
Pressure.
timer upto 99.9 sec
Ball Pressure: Dia
2.5mm, 20N
Radiation, Toxicity and IS 302-2-25 (Clause 32) / IEC Microwave leakage:

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 48 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Similar Hazards 60335-2-25 upto 100W/m2
Marking & Instruction IS 302-2-26 Qualitative
(Clause.7) /IEC 60335-2-26 (Visual)
Protection Against IS 302-2-26 Force:0.1 N to 1000 N
Electric Shock & Energy (Clause.8) /IEC 60335-2-26 Length: 0.01mm to
Hazards 300 mm
Test probes
Voltage: Upto
60V/LC0.01V
Input IS 302-2-26 Voltage: AC: 0 to
(Clause.10) /IEC 60335-2-26 300V
Current: AC: 0.01A
to10 A
Wattage: 0.1W to1
kW
Temperature Rise IS 302-2-26 Voltage: AC: 0 to
(Heating) (Clause.11) /IEC 60335-2-26 300V
Current: AC: 0.001A
to10 A
Wattage: 0.1W to1
kW
Temp:0.1oC to 300 oC
Leakage Current and IS 302-2-26: H. V.: 0.1 kV to 10 kV
Electrical Insulation at (Clause.13) /IEC 60335-2-26: AC
Operating Temperature DC: 0.1 kV to 5/0.1
kV
Tripping
current:10mAto300
mA
Time: 10 ms to 9000
s Leakage Current:
upto
1 µA to 500 mA

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 49 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Transient over Voltage IS 302-2-26: Impulse Voltage upto
(Clause. 14) / 300 volt to 10 kV
IEC 60335-2-25:
Moisture Resistance IS 302-2-26: Temp: 25 ºC to 50 ºC
(Clause.15) / RH : 30% to 95%
IEC 60335-2-26:
Insulation Resistance IS 302-2-26: Resistance :
and Electrical Strength (Clause.16) / 1 kΩ to 2000 MΩ;
(After Humidity IEC 60335-2-26: 500VDC
Treatment) H. V.: 0.1 kV to 10 kV
AC
DC: 0.1 kV to 5/0.1
kV
Tripping current:0
to300 mA
Time: 10 ms to 9000 s
Abnormal Operation IS 302-2-26: Current AC: 5 mA to
(Clause.19) / 20 A
IEC 60335-2-26: Wattage: 0.1W to 1
kW
Temperature:
0.01°C to 200°C
Mechanical Strength IS 302-2-26: Angle : 0 to 90 °
(Clause.21) / Force gauge: 0.1 N
IEC 60335-2-26: to 1000 N
Voltage 0.1V to 10 kV
Construction IS 302-2-26: Force gauge: 0.1 N
(Clause.22) / to 1000 N
IEC 60335-2-26: Microwave Leakage:
100w/m2
Internal Wiring IS 302-2-26: Visual
(Clause.23) /
IEC 60335-2-26:

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 50 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Components IS 302-2-26: Visual
(Clause.24) /
IEC 60335-2-26:
Creepage Distances, IS 302-2-26: i) Peak Voltage VAC:
Clearances Distance (Clause.28)/ 50mVp-p to 400 Vp-p
and Tracking IEC 60335-2-26: ii) Length: 0.01 mm
to 300 mm
iii) Force : 0.1 N to
500 N
iv) CTI: Up to
600V,10Amp,100
Count
Resistance To Heat and IS 302-2-26: Distance: 0.01mm to
fire (Clause.30)/ 300mm
IEC 60335-2-26: Temp: 1 to 1000 ºC
fro Glow Wire & upto
250 ºC for Ball
Pressure.
timer upto 99.9 sec
Ball Pressure: Dia
2.5mm, 20N
2. Un-interruptible Marking & Instructions, IS 16242 (Part 1) Voltage: up to
Power Systems Power Rating (Clause. 4.7) 300/0.1 AC V, up to
(UPS) IEC 62040-1 30/0.1 V DC
Current: 0.01A to 10 A
Wattage:0.0001 W to
03 kW
Protection Against IS 16242 (Part 1) Qualitative
Electric Shock and (Clause. 5.1) i) Force:0.1 N to
Energy Hazards IEC 62040-1 1000 N
Length:0.01mm to
300 mm
Test probe fig. 2A
ii) Voltage: up to

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 51 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
300/0.1 AC V, up to
30/0.1 V DC
Current: 0.01A to10
A
0.005 mA to 10 mA
Force: 0.1 N to 1000
N
Safety Extra Low IS 16242 (Part 1) Peak Voltage VAC:
Voltage circuit -SELV (Clause. 5.2.1) 50mVp-p to 400 Vp-p
IEC 62040-1
Limited Current Circuit IS 16242 (Part 1) Resistance:
(Clause. 5.2.3) 2000Ohm
IEC 62040-1 Peak Voltage VAC:
50mVp-p to 400 Vp-p
Limited Power Source IS 16242 (Part 1) Voltage: up to
Measurement (Clause. 5.2.5) 300/0.1 AC V, up to
IEC 62040-1 30/0.1 V DC
Current: 0.01A to10 A
DC Voltage upto 50
Volt
DC Current upto 10
Amp.
Protective Earthing & IS 16242 (Part 1) Voltage 0.10 V to
Bonding (Clause. 5.3) 14.24 V
IEC 62040-1 Current 0.1 A to 300 A
Protection of Personnel IS 16242 (Part 1) Qualitative
– Safety Interlocks (Clause. 5.6) Force:0.1 N to 1000
IEC 62040-1 N
Length: 0.01mm to
300 mm
Test probe fig. 2A
Clearance, Creepage IS 16242 (Part 1) Voltage: 0.5V to 300
Distance and Distance (Clause. 5.7) V

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 52 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
through Insulation IEC 62040-1 Force : 0.1 N to 500
Clause No: 2.10.2, 2.10.3, N
2.10.3.9a, 2.10.4 Length: 0.01mm to
300 mm
Impulse 1.2/50µS
upto 0.01kV to 10kV
Stability IS 16242 (Part 1) Qualitative
(Clause. 7.2) Angle : 10 °
IEC 62040-1 Force gauge: 0.1 N
to 1000 N

Mechanical Strength IS 16242 (Part 1) Force gauge:0.1N to


(Clause. 7.3) 500N
IEC 62040-1 Scale :0.001 m to 3 m
Mass: 500 g
Ball Dia : (50 ± 1) mm
Vernier:0.01mm to
150 mm
Temperature :
1°C to 250 °C
Resistance to Fire IS 16242 (Part 1) Distance: 0.01mm to
(Clause. 7.5) 300mm
IEC 62040-1 Temp: 1 to 1000 ºC
for Glow Wire & upto
250 ºC for Ball
Pressure.
timer upto 99.9 sec
Ball Pressure: Dia
2.5mm, 20N
Temperature Rise IS 16242 (Part 1) Voltage: AC: 0 to
(Clause. 7.7) & (Clause. 8) 300V
IEC 62040-1 Current: AC: 0.001A
to10 A
Wattage: 0.1W to1

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 53 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
kW
Temp:0.1oC to 300 oC
Electrical Strength IS 16242 (Part 1) H. V.: 0.1 kV to 10 kV
(Clause. 8.2) AC
IEC 62040-1 DC: 0.1 kV to 5/0.1
kV
Tripping current:0 to
300 mA
Time: 10 ms to 9000 s

Abnormal Operating and IS 16242 (Part 1) Voltage: AC: 0 to


Fault Conditions (Clause. 8.3) 300V
IEC 62040-1 Current: AC: 0.01A
to10 A
Wattage: 0.1W to1
kW
3. General Purpose Marking IS 10322 (Part 1) Qualitative
Luminaires (Section 3) (Visual Inspection)
-General IEC 60598-1
Requirements and (Eight Edition)
Test EN 60598-1
Constructions IS 10322 (Part 1) Test Prob 13
(Cl.4.10.2 Section 4)
IEC 60598-1
(Eight Edition)
EN 60598-1
Screw and connections IS 10322 (Part 1) Force: 0.1 N to 1000 N
(Mechanical) (Cl.4.12.1, Section 4) Torque: Upto 6 Nm
IEC 60598-1
(Eight Edition)
EN 60598-1
Mechanical Strength IS 10322 (Part 1) Impact Energy: 0.1 to

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 54 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
(Cl.4.13.1 & Cl.4.13.3, 4.13.6, 6 J. Spring hammers.
Section 4) Ball Dia:(50 ± 1) mm
IEC 60598-1 & Mass 500gram
(Eight Edition) 30N test Finger
EN 60598-1 Tumbling Barrel
Upto 999999 count
Vibration Test IS 10322 (Part 1) Frequency:
(Cl.4.20 Section 4) 5 to 100 Hz
IEC 60598-1 Acceleration 1 to 10g
(Eight Edition) Amplitude +25 to
EN 60598-1 (-) 25 mm

Mechanical Hazard IS 10322 (Part 1) Qualitative


(Cl.4.25 Section 4) (Visual Inspection)
IEC 60598-1
(Eight Edition)
EN 60598-1
External and Internal IS 10322 (Part 1) i) Test probe fig. 2A
wiring Cl.5.1,Cl.5.2(Section 5) ii) H. V.: 0.1 kV to 10
IEC 60598-1 kV AC
(Eight Edition) DC: 0.1 kV to 5/0.1 kV
EN 60598-1 Tripping current: 0
to300 mA
iii) Measurement
0.01mm to 150mm
iv) Resistance: 0.2µΩ
to 11Ω.
v) Flexing: 1 count to
99999 counts.
vi) Load: Upto 1000 N.
Provision For Earthing IS 10322 (Part 1) Voltage 0.10 Volt to
(Section 7) 14.24 V
IEC 60598-1 Current 0.1Amp to
(Eight Edition) 300 Amp

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 55 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
EN 60598-1
Protection Against IS 10322 (Part 1) i) Force:0.1 N to
Electric Shock (Section 8) 1000 N
IEC 60598-1 Length: 0.01mm to
(Eight Edition) 300 mm
EN 60598-1 Test probe fig. 2A
ii) Voltage: up to
300/0.1 AC V, up to
30/0.1 V DC
Current: 0.01A to10 A
0.005 mA to 10 mA
Force: 0.1 N to1000 N
Resistance to Dust, IS 10322 (Part 1) Dust Test: Size
Solid Object and (Cl.9.1 to 9.2.9 Section 9) 1x1x1 mtr3
moisture IEC 60598-1 Test Finger:1 mm to
(Eight Edition) 5 mm
EN 60598-1 Force: 0.1 N to1000 N
Rain Test: pressure
upto 100kN/m2
IP1 drip Box, IP3
Oscillating Tube
Spray Test
Apparatus, IP5 Jet
Nozzle test
apparatus, IP6 Jet
Nozzle test
apparatus, IP7
Immersion tank.
Humidity Test IS 10322 (Part 1): Temp: upto 450C
(Cl.9.3 Section 9) RH: upto 95%
IEC 60598-1 (Eight Edition)
EN 60598-1
Insulation Resistance IS 10322 (Part 1): Resistance :
and Electric Strength (Cl.10.1 to 10.2 Section 10) 1 kΩ to 2000 MΩ;

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 56 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
IEC 60598-1 500VDC
(Eight Edition) H. V.: 0.1 kV to 10 kV
EN 60598-1 AC
DC: 0.1 kV to 5/0.1
kV
Tripping current:0
to300 mA
Time: 10 ms to 9000 s
Leakage Current IS 10322 (Part 1) 0.1 mA to100 mA
(Cl.10.3 Section 10)
IEC 60598-1 (Eight Edition)
EN 60598-1
Creepage Distances & IS 10322 (Part 1) i) Peak Voltage VAC:
Clearances (Section 11) 50mVp-p to 400 Vp-p
IEC 60598-1 ii)Length:0.01mm
(Eight Edition) to300 mm
EN 60598-1 iii) Force : 0.1 N to
1000 N
iv) CTI: Up to
600V,10Amp,100
Count ,
Resistance to Heat, Fire IS 10322 (Part 1) Distance:0.01mm to
and Tracking (Section 13) 300mm
IEC 60598-1 Temp: 1 to 1000 ºC
(Eight Edition) fro Glow Wire & upto
EN 60598-1 250 ºC for Ball
Pressure.
timer upto 99.9 sec
Ball Pressure: Dia
2.5 mm, 20N
CTI: Up to
600V,10Amp,100
Count ,
Screw Terminals IS 10322 (Part 1) Force: 0.1N to 1000N

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 57 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
(Section 14) Torque: Up to 6 Nm
IEC 60598-1
(Eight Edition)
EN 60598-1
Screwless Terminals IS 10322 (Part 1) Force: 0.1 N to1000 N
and Electrical (Section 15.5) Torque: Up to 6 Nm
Connections IEC 60598-1 (Eight Edition) Length:0.01mm to
EN 60598-1 300 mm

IV. ENVIRONMENTAL TEST FACILITY

1. Environmental I.P. (Degrees of Cl.5.1 & Cl.12.2 of IEC 60529 Dia. of probe:0.5mm
Test protection against to 50mm
access to hazardous
parts indicated by first
numeral 0 to 6 ):
I.P. (Degrees of Cl.5.2 & Cl.13.2 to 13.6 of IEC Dia. of probe:0.5mm
protection against solid 60529 to 50mm
foreign objects indicated Dust Chamber Size
by first numeral 0 to 6 ): 1x1x1mtr3
I.P. (Degrees of Cl.6 & Cl.14.2.1 to Cl.14.2.8 of Drop at 150 Angle,1
protection against IEC 60529 rpm to 10 rpm.
ingress of water Water Spray at 600
indicated by Second Angle: upto 1600mm
numeral 0 to 6 ): Radius & upto 200
kPa,2-lpm
Splashed Water
Jet Spray:6.3mm&
12.5mm,12.5l/m to
100l/m

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 58 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Immersion
Tanks:upto 1m
Dry Heat IS 9000 (Part 3/Sec I to V) Temp: 0 °C to 250 °C
IEC 60068(-)2-2 Rate of Change of
temp 0.5°C to 5°C
upto
Dry Cold IS 9000 (Part 2/ Sec I to IV) Temp: 0 °C to - 40 °C
IEC 60068-2-1 Rate of Change of
temp
(-)0.5°C to(-)5°C upto
Thermal Shock Test IS 9000 (Part 14/ Sec II) Temp: 250 °C to
IEC 60068-2-14 (-)40 °C

Damp Heat (Cyclic) IS 9000 (Part 5/ Sec I & II) Temp.: 25±10 °C to
IEC 60068-2-30 40±2°C
Humidity upto 95%
RH
Rate of Change of
temp 0.5°C to 5°C
upto
2. DC or AC Marking IS 15885 (Part 2/Sec XIII): / IS Qualitative (Visual)
supplied 15885-1 Clause. 7
electronic control Protection against IS 15885 (Part 2/Sec XIII): / IS Force:0.1 N to 1000 N
gear for LED accidental contact with 15885-1 Clause. 8 Length:0.01mm to
Modules live parts 300 mm
Test probes
Voltage: Upto
60V/LC0.01V
Terminals IS 15885 (Part 2/Sec XIII): / IS Force:0.1 N to 1000 N
15885-1 Clause. 9 Length:0.01mm to
300 mm
Provision for protective IS 15885 (Part 2/Sec XIII): / IS Voltage 0.10 V to
earthing 15885-1 Clause. 10 14.24 V

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 59 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Current 0.1A to 300 A
Moisture Resistance IS 15885 (Part 2/Sec XIII): / IS Temp: 25 ºC to 50 ºC
15885-1 Clause. 11 RH : 30% to 95%
Electric Strength IS 15885 (Part 2/Sec XIII): / IS H. V.: 0.1 kV to 10 kV
15885-1 Clause. 12 AC
DC: 0.1 kV to 5/0.1
kV
Tripping current:0
to300 mA
Time: 10 ms to 9000 s
Fault conditions IS 15885 (Part 2/Sec XIII): / IS Voltage: AC: 0 to
15885-1 Clause. 14 300V
Current: AC: 0.001A
to10 A
Wattage: 0.1W to1
kW
Transformer heating IS 15885 (Part 2/Sec XIII): / IS Voltage: AC: 0 to
15885-1 Clause. 15 300V
Current: AC: 0.001A
to10 A
Wattage: 0.1W to1
kW
Temp:0.1oC to 300 oC
Construction IS 15885 (Part 2/Sec XIII): / IS Angle : 0 to 90 °
15885-1 Clause. 16 Force gauge: 0.1 N
to 1000 N
Creepage distance and IS 15885 (Part 2/Sec XIII): / IS i) Peak Voltage VAC:
clearances 15885-1 Clause. 17 50mVp-p to 400 Vp-p
ii)Length:0.01mm
to300 mm
iii) Force : 0.1 N to
500 N
iv) CTI: Up to 600V,

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 60 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
10Amp,100 Count
Screws, current-carrying IS 15885 (Part 2/Sec XIII): / IS Force: 0.1 N to1000 N
parts and connections 15885-1: Clause. 18 Torque: 0.1 to 6 Nm
Time: 10 ms to 9000 s
Resistance to heat, fire IS 15885 (Part 2/Sec XIII): / IS Distance: 0.01mm to
and tracking 15885-1: Clause 19 300mm
Temp: 1 to 1000 ºC
fro Glow Wire & upto
250 ºC for Ball
Pressure.
timer upto 99.9 sec
CTI: Up to 600V,
10Amp,100 Count

3. Self Ballasted Led Marking IS 16102 (Part1) Qualitative (Visual)


Lamps For Clause. 5
General Lighting Interchange ability IS 16102 (Part1) Force: 0.1 N to
Services Clause. 6 1000N
Torque: 0.1 to 6 Nm
Time: 10 ms to 9000 s
Protection against IS 16102 (Part1) Force:0.1 N to 1000 N
Electric Shock Clause. 7 Length: 0.01mm to
300 mm
Test probes
Voltage: Upto
60V/LC0.01V
Insulation Resistance IS 16102 (Part1) Resistance :
and Electric Strength Clause. 8 1 kΩ to 2000 MΩ;
after Humidity Treatment 500VDC
H. V.:0.1 kV to10 kV
AC
DC: 0.1 kV to 5/0.1
kV

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 61 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Tripping current:
0 to 300 mA
Time: 10 ms to 9000 s
Temp: 25 ºC to 50 ºC
RH : 30% to 95%
Mechanical Strength IS 16102 (Part1) Angle : 0 to 90 °
Clause. 9 Force : 0.1 N to 100 N
Cap Temperature rise IS 16102 (Part1) Voltage: AC: 0 to
Clause. 10 300V
Current: AC: 0.001A
to10 A
Wattage: 0.1W to1
kW
Temp:0.1oC to 300 oC

Resistance to Heat IS 16102 (Part1): 2012 Ball Pressure: Dia 2.


Clause. 11 5mm, 20N
Resistance to Flame and IS 16102 (Part1): 2012 Distance: 0.01mm to
ignition Clause. 12 300mm
Temp: 1 to 1000 ºC
fro Glow Wire & upto
250 ºC for Ball
Pressure.
timer upto 99.9 sec
Fault conditions IS 16102 (Part1): 2012 Voltage: AC: 0 to
Clause. 13 300V
Current: AC: 0.001A
to10 A
Wattage: 0.1W to1
kW
Creepage distance and IS 16102 (Part1): 2012 i) Peak Voltage VAC:
clearances Clause. 14 50mVp-p to 400 Vp-p
ii)Length:0.01mm

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 62 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
to300 mm
iii) Force : 0.1 N to
500 N
iv) CTI: Up to
600V,10Amp,100
Count

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 63 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed

ELECTRONICS TESTING

LOCATION-2

I. DOMESTIC ELECTRONIC APPLIANCES & ACCESSORIES

1. Electronics Normal operating IS 616:2017 i) Programmable AC


Product condition /IEC 60065 : 2014 source: Voltage: up
(Audio, Video and Cl.4.2, Cl.4.2.1,Cl.4.2.2, to 300.0V/0.1 AC V,
Similar Electronic Cl.4.2.3,Cl.4.2.4,Cl.4.2.5 up to 424.20/0.1 V
Apparatus) Cl.4.2.6,Cl.4.2.7,Cl.4.2.8, DC Current:
Cl.4.2.9,Cl.4.2.10, 0.01A to 32.40A
IS 616:2017/IEC Cl.4.2.10.1, Cl.4.2.10.2, Wattage:
60065 : 2014 Cl.4.2.11,Cl.4.2.12, & 4.2.13 0.01 W to 03 kW
Frequency:
upto 100 Hz/0.01 Hz
ii) Digital Power
meter: Voltage:
up to 600V/0.01 AC
V, Current: up to
20A/0.001A AC,
Wattage: 0.001 W
iii) Pink Noise
generator:
Up to 1KHz
iv) Function
Generator:
up to 50MHz
v) Resistive Load:
up to 250 Ohm,50W
vi) Multimeter :
Voltage up to
600V/0.001V AC,

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 64 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
up to 600V/0.001V
DC, Current:
up to 10A/0.001A AC
and DC, Resistance:
600KΩ.
vii) Three Vertical bar
signal as per IEC
60107-1: 1997.
viii) Digital Storage
Oscilloscope:
Voltage: up to 300V,
Resistance: 1 MΩ,
ix) DC electronic
load: LV: up to 15V
DC/0.001V DC, HV:
up to 150V
DC/0.01VDC,
Low current: up to
2.1A/0,1mA, Middle
current:
up to 21A/0.001A
DC, High current:
210A/0.01A DC
x) Stop Watch:
99.9min./0.01 sec.
Fault Condition IS 616:2017/ i) Programmable AC
IEC 60065 : 2014 source: Voltage:
Cl.4.3, Cl.4.3.1, Cl.4.3.2, up to 300.0V/0.1 AC
Cl.4.3.3, Cl.4.3.4, Cl.4.3.5, V, up to 424.20/0.1 V
Cl.4.3.6, Cl.4.3.7, Cl.4.3.8, DC Current: 0.01A to
Cl.4.3.9, Cl.4.3.10, Cl.4.3.11, 32.40A
Cl.4.3.12, Cl.4.3.13, Cl 4.3.14, Wattage: 0.01 W to
Cl.4.3.15, Cl.4.3.16, Cl.4.3.17 03 kW
Frequency: up to 100

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 65 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Hz/0.01 Hz
Resistance: up to
20Ω,09Amp
ii) Multimeter :
Voltage up to
600V/0.001V AC,
up to 600V/0.001V iii)
Test Circuit as per fig
1: up to 999 min/
iv) Pink Noise
generator: Up to 1KHz
v) Piece of card:
200g/m2 density,
vi) Angle finder:
up to 90 deg.
vii) Three Vertical bar
signal as per IEC
60107-1: 1997
viii) Paper less
recorder
(Temperature data
logger):
Upto 1100deg.
/0.1deg.
Stop Watch:
99.9min./0.01sce.
Marking & Instructions IS 616:2017/ Qualitative
IEC 60065 : 2014
Clause No: 5
General Requirements IS 616:2017/ Petroleum spirit,
IEC 60065 : 2014 Water, Cotton Cloth
Cl.5.1 Stop Watch:
99.9min./0.01sce

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 66 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Identification and supply IS 616:2017/ Qualitative
ratings IEC 60065 : 2014 Cl.5.2
Terminals IS 616:2017/ Qualitative
IEC 60065 : 2014 Cl.5.3

Caution Marking IS 616:2017/ Qualitative


IEC 60065 : 2014 Cl.5.4
Instructions IS 616:2017/IEC 60065 : 2014 Qualitative
Cl.5.5, Cl.5.5.1, Cl.5.5.2,
Cl.5.5.3
Heating under normal IS 616:2017/IEC 60065 : 2014 i) Paper less recorder
operating conditions Cl.7, Cl.7.1, Cl.7.1.1, Cl.7.1.2, (Temperature data
Cl.7.1.3, Cl.7.1.4, Cl.7.1.5, logger): up to
Cl.7.1.6 1100deg. /0.1deg
ii) Resistive Load: up
to 250 Ohm,50W
iii) Multimeter :
Voltage up to
600V/0.001V AC, up
to 600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
iv) Multi Test Panel:
Voltage: up to
300Volt/
Current: 30A/LC
0.001A AC
v)Three Vertical bar
signal as per IEC
60107-1: 1997
vi) DC electronic
load: LV: up to 15V
DC/0.001V DC, HV:

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 67 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
up to 150V
DC/0.01VDC, Low
current: up to
2.1A/0,1mA, Middle
current: up to
21A/0.001A DC, High
current: 210A/0.01A
DC
vii) Pink Noise
generator: Up to
1KHz
viii) Function
Generator: up to
50MHz
ix) Scale: up to
150mm
Heat resistance of IS 616:2017/IEC 60065 : 2014 i)Vicat Softening
insulating material Cl.7.2 Temperature Test
apparatus
ii) Temp: Up to
150ºC
iii) Load: 10 N
Construction IS 616:2017/IEC 60065 : 2014 Qualitative
requirement with regard Cl.8, Cl.8.1
to the protection against
electric shock
Operations by Hand IS 616:2017/IEC 60065 : 2014 i) PAES: 0-70V/
Cl.8.2
ii) Multi Test Panel:
up to 300 Volt/
iii)Leakage current
Tester: 25V
Current: up to

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 68 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
20mA/
iv) Touch Current
measurement test
circuit: 0- 70 mA
200mV/
v) Multimeter :
Voltage up to
600V/0.001V AC, up
to 600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
vi) Test Probe B
vii) Test Probe 18
viii) Test probe 19
ix) Test Probe 13
x) Push Pull:
1000N/LC:0.1N
xi) Metal Test Pin
xii) Test Probe D
xiii) Test Probe C
xiv) Test Probe 11
xv) Digital Storage
Oscilloscope:
Voltage: up to 300V,
Resistance: 1 MΩ,
Up to 100 MHz
xvi) Stop Watch:
99.9min./0.01sec.
xvii) Test Hook
Hygroscopic materials. IS 616:2017/ i)Oven with humidity
IEC 60065 : 2014 Cl.8.3 Chamber: Temp: up
to 80deg/
Humidity: up to 98%

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 69 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed

ii)Insulation Meter:
106MΩ/
iii) AC-DC
withstanding voltage:
up to 5 KV/
AC Volt: Up to 5KV/
0.01KV
iii) Stop Watch:
99.9min./0.01sec.
iv) Metal foil
Electric shock IS 616:2017/IEC 60065 : 2014 Qualitative
hazardous Cl.8.4, Cl.8.5, Cl.8.6 & Cl. 8.7
IS 616:2017/IEC 60065 : 2014 i) Vernier: 150mm/
Cl.8.8,Cl.8.9,
Cl.8.10,Cl.8.11 & Cl.8.12 ii) Micrometer: up to
25mm/
iii) AC-DC
withstanding voltage:
up to 5 KV/
iv) Metal foil
v) Metal Rod: Length
10 cm.
vi) Push Pull Tester,:
Force : 1000N/

vii)Vibration machine
: Frequency: 5 to
100 Hz
Acceleration 1 to 10g
Amplitude 0.35mm

IS 616:2017/IEC 60065 : 2014 i) Push Pull Tester,

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 70 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Cl.8.13,Cl.8.14, Cl.8.15 & Force : 1000N/
Cl.8.16
ii) Timer: up to
1800/0.1 Sec.
Endurance test for IS 616:2017/IEC 60065 : 2014 i) Oven with humidity
wound components with Cl.8.17 Chamber: Temp: up
insulated winding wires to 80deg/,
without Humidity: up to 98%/
additional interleaved
ii) Vibration:
insulation
Frequency:5 to100
Hz
Acceleration 1 to 10g
Amplitude 0.35mm,
iii) Insulation
resistance, : 106 MΩ
iv) AC-DC
withstanding voltage:
up to 5 KV/
v) Vibration:
Frequency: 2000Hz
vi) Stop Watch:
99.9min.
Disconnection from the IS 616:2017/IEC 60065 : 2014 i) Vernier: up to
mains Cl.8.18 , Cl.8.19 & Cl.8.20 150mm/
ii) Micrometer: up to
25/0.001mm
Test specifications of IS 616:2017/IEC 60065 : 2014 i) Push Pull: Force:
non-separable thin sheet Cl.8.21 1000N/
material ii) Micrometer: up to
25mm/0.001 mm
iii) Scale: up to 300/
0.5 mm
iv) Stop Watch:

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 71 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
99.9min./0.01sec,
v) Metal Foil
vi) Multimeter :
Voltage up to
600V/0.001V AC, up
to 600V/0.001V
vii) AC-DC
withstanding voltage:
up to 5 KV/

Electric shock hazard IS 616:2017/IEC 60065 : 2014 i) PAES: 0-70V/


under normal operating Cl.9 ,Cl.9.1, Cl.9.1.1,
ii) AC Supply: up to
conditions Cl.9.1.1.1, Cl.9.1.1.2,
300 Volt
Cl.9.1.1.3
iii) Leakage current
Tester: 25V/,
Current: up to
20mA/0.001µA
iv)Touch Current
measurement test
circuit: 0- 70 mA
200mV/
v) Multimeter :
Voltage up to
600V/0.001V AC, up
to 600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
vi) Test Probe B
vii) Test Probe 18
viii) Test probe 19
ix) Test Probe 13
Shafts of operating IS 616:2017/IEC 60065 : 2014 AC Supply: up to 250

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 72 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
nonbs, Handles, Levers Clause No: 9.1.2 Volt
and the like Leakage current
Tester: 25V/,
Current: up to
20mA/0.001µA
Touch Current
measurement test
circuit: 0- 70 mA
200mV
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
Opening of the IS 616:2017/ Metal Test Pin
enclosure IEC 60065 : 2014
Clause No: 9.1.3
Terminals IS 616:2017/ Test Probe D
IEC 60065 : 2014 Push Pull : Force:
Clause No: 9.1.4 1000N

Pre-set control IS 616:2017/ Test Probe C


IEC 60065 : 2014 Push Pull Force:
Clause No: 9.1.5 1000N
Withdrawal of mains IS 616:2017 AC Supply: up to 250
plug /IEC 60065 : 2014 Volt
Clause No: 9.1.6 Leakage current
Tester: 25V/,
Current: up to
20mA/0.001µA
Touch Current
measurement test

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 73 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
circuit: 0- 70 mA
200mV/,
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
Resistance to external IS 616:2017/ Test Probe 11, Push
forces IEC 60065 : 2014 Pull Force:
Clause No: 9.1.7 1000N
Stop Watch:
99.9min./0.01sec ,
Test Hook,
Removal of protective IS 616:2017/ PAES: 0-70V/
covers IEC 60065 : 2014
Cl.9.2 AC Supply: up to 250
Volt/LC 1 Volt
Leakage current
Tester: 25V/,
Current: up to
20mA/0.001µA
Touch Current
measurement test
circuit: 0- 70 mA
200mV/
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 74 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Test Probe B, Test
Probe 18, Test probe
19, Test Probe 13,
Push Pull Force:
1000N/
Metal Test Pin, Test
Probe D, Test Probe
C, Test Probe 11,
Digital Storage
Oscilloscope:
Voltage: up to 300V,
Resistance: 1 MΩ,
Up to 100 MHz
Stop Watch:
99.9min./0.01sce.
Test Hook
Insulation requirements IS 616:2017/ Qualitative
IEC 60065 : 2014 Cl.10
Frequencies IS 616:2017/ upto 30 kHz
IEC 60065 : 2014 Cl.10.1

Surge test IS 616:2017/ Surge Test


IEC 60065 : 2014 Cl.10.2 Apparatus :
up to 10 kV,
50 Discharge , 12
Discharge /minute
Humidity Test IS 616:2017/ Oven with humidity
IEC 60065 : 2014 Clause No: Chamber: Temp: up
10.3 to 80deg/
Humidity: up to 98%
Insulation Resistance IS 616:2017/ Insulation

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 75 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
IEC 60065 : 2014 Clause No: Meter:106MΩ
10.4, Cl.10.4.1, Cl.10.4.2 AC-DC withstanding
voltage: up to 5 KV/
LC 0.001KV,
Stop Watch:
99.9min./0.01sec.
Metail foil
Fault condition IS 616:2017/ Qualitative
IEC 60065 : 2014 Cl.11
Electric shock hazard IS 616:2017/ PAES: 0-70V/ LC
IEC 60065 : 2014 Cl.11.1 0.1V
AC Supply: up to 300
Volt/LC 1 Volt
Leakage current
Tester: 25V/,
Current: up to
20mA/0.001µA
Touch Current
measurement test
circuit: 0- 70 mA
200mV/
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V
Heating test IS 616:2017/ Paper less recorder
IEC 60065 : 2014 Cl.11.2, (Temperature data
Cl.11.2.1, Cl.11.2.2, Cl.11.2.3, logger): up to
Cl.11.2.4, Cl.11.2.5, Cl.11.2.6, 1100deg. /0.1deg
Cl.11.2.7, Cl.11.2.8 Resistive Load: up to
250 Ohm,50W
Miultimeter : Voltage
up to 600V/0.001V
AC, up to

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 76 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
Multi Test Panel:
Voltage: upto 300Volt
Current: 30A
3 Vertical bar signal
as per IEC 60107-1:
1997
DC electronic load:
LV: up to 15V
DC/0.001V DC, HV:
up to 150V
DC/0.01VDC, Low
current: up to
2.1A/0,1mA, Middle
current: up to
21A/0.001A DC, High
current: 210A/0.01A
DC
Pink Noise
generator: Up to
1KHz
Function Generator:
up to 50MHz
Scale: up to 150mm
Mechanical strength IS 616:2017/IEC 60065 : 2014 Qualitative
Cl.12
Complete apparatus IS 616:2017/IEC 60065 : 2014 Qualitative
Cl.12.1
Requirements IS 616:2017/IEC 60065 : 2014 Qualitative
Cl.12.1.1

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 77 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Bump Test IS 616:2017/IEC 60065 : 2014 Weighing balance :
Cl.12. 1.2 upto 50kg/0.01kg
Bump Test : Height
5cm, 50 times
Vibration Test IS 616:2017/IEC 60065 : 2014 Frequency:5 to100 Hz
Cl.12.1.3 Acceleration 1 to 10g
Amplitude 0.35mm
Impact Test IS 616:2017/IEC 60065 : 2014 Impact Energy: 0.5
Cl.12.1.4 J , Spring hammer
mass up to 500gm
Vernier: upto 150/
0.01 mm
Ball Dia: (50 ± 1)
mm, 500g
AC-DC withstanding
voltage: up to 5 KV/
Stop Watch:
99.9min./0.01sec.
Metail foil
Drop Test IS 616:2017/IEC 60065 : 2014 Weighing balance :
Cl.12.1.5 upto 50kg/0.01kg
Measuring Test :
0.001 m to1 m
AC-DC withstanding
voltage: up to 5 KV,
Stop Watch:
99.9min./0.01sec.
Metal foil
Vernier: upto 150/
0.01 mm

Stress relief Test IS 616:2017/ Oven with humidity


IEC 60065 : 2014 Cl.12.1.6 Chamber: Temp: up

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 78 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
to 80deg/LC 0.1deg,
Humidity: up to 98%
Fixing of actuating IS 616:2017/ Push Pull: Force:
elements IEC 60065 : 2014 Cl.12.2 1000N/0.1N
Torque: 0.1 to 6 Nm
Weighing balance :
50kg/0.01kg
Stop Watch:
99.9min./0.01sec.
Remote Control Devices IS 616:2017/ Tumbling Barrel Test
held in hand IEC 60065 : 2014 Cl.12.3 Apparatus: Count:
Up to 999999/1 count
Weighing balance :
50kg/0.01kg
Vernier: upto 150/
0.01 mm
Drawer IS 616:2017/ Push Pull: Force:
IEC 60065 : 2014 Cl.12.4 1000N/
Stop Watch:
99.9min./0.01sec.
Test Probe B,
Antenna coaxial Sockets IS 616:2017/ Impact: up to 3.5 J
mounted on the IEC 60065 : 2014 Cl.12.5 Force: up to 300/1 N
apparatus Timer: up to 1800/0.1
Sec
Telescoping or rod IS 616:2017 Push Pull :
antennas /IEC 60065 : 2014 Cl.12.6, 1000N/
Cl.12.6.1, Cl.12.6.2 Stop Watch:
99.9min./0.01sec.
Vernier: upto 150/
0.01 mm
Micrometer: upto
25mm/

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 79 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Torque: 0.02 to 1.2 /
0.01 Nm
Appratus containing IS 616:2017/ Qualitative
coin/Button Cell Batteries IEC 60065 : 2014 Cl.12.7
General IS 616:2017/ Vernier: upto 150/
IEC 60065 : 2014 Cl. 12.7.1 0.01 mm
Construction IS 616:2017 Qualitative
Requirements /IEC 60065 : 2014 Cl. 12.7.2
Tests IS 616:2017/ Oven with humidity
IEC 60065 : 2014 Cl. 12.7.3, Chamber: Temp: up
Cl. 12.7.3.1, Cl 12.7.3.2, Cl. to 80deg
12.7.3.3, Cl. 12.7.3.4, Cl. Humidity: up to
12.7.3.5, Cl. 12.7.3.6 98%/
Torque: 0.02 – 1.2
/0.01Nm
Weighing balance :
50Kg/0.01kg
Measuring Test :
0.001 m to1 m
AC-DC withstanding
voltage: up to 5 KV/
Stop Watch:
99.9min./0.01sec.
Metal foil Vernier:
upto 150/ 0.01 mm
Impact Energy: 0.5J
to Vernier: upto 150/
0.01 mm
Ball Dia: (50 ± 1)
mm, 500g
AC-DC withstanding
voltage: up to 5 KV/ ,
Crush Test

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 80 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
apparatus: upto:
20kN:
Compliance IS 616:2017/ Test Probe 11
IEC 60065 : 2014 Stop Watch:
Cl. 12.7.4 99.9min./0.01sec.
Push Pull : Force:
1000N/0.1N
Test Probe B, Test
Hook
Clearance & Creepage IS 616:2017/ Qualitative
distances IEC 60065 : 2014
Cl: 13, & Cl.13.1
Determination of working IS 616:2017/ Digital Storage
Voltage IEC 60065 : 2014 Oscilloscope:
Cl.13.2 Voltage: up to 300V,
Resistance: 1 MΩ,
Up to 100 MHz,
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
Clearances IS 616:2017/ Vernier: 0-150
IEC 60065 : 2014 mm/LC 0.01mm
Cl.13.3,13.3.1, 13.3.2 & 13.3.3 PAES: 0-70V/
Test Probe B, Push
Pull1000N/
Test Probe 11
Measurement of IS 616:2017/ Digital Storage
transient Voltages IEC 60065 : 2014 Oscilloscope:
Cl.13.3.4 a Voltage: up to 300V,

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 81 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Resistance: 1 MΩ,
Up to 100 MHz,
Impulse: 1.2/50 µS

Measurement of IS 616:2017/ Impulse: 10/700 µS


transient Voltages IEC 60065 : 2014 upto 10kV
Cl.13.3.4 b
Creepage Distances IS 616:2017/ Digital Storage
IEC 60065 : 2014 Oscilloscope:
Cl.13.4 Voltage: up to 300V,
Resistance: 1 MΩ,
Up to 100 MHz,
Vernier: 0-150
mm/
PAES: 0-70V/
Test Probe B
Printed Boards IS 616:2017/ Qualitative
IEC 60065 : 2014
Cl.13.5
Jointed Insulation IS 616:2017/ Digital Storage
IEC 60065 : 2014 Oscilloscope:
Cl.13.6 Voltage: up to 300V,
Resistance: 1 MΩ,
Up to 100 MHz,
Vernier: 0-150
mm/
PAES: 0-70V/ Test
Probe B,
Oven with humidity
Chamber: Temp: up
to 80deg/
Humidity: up to 98%

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 82 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed

Enclosed and sealed IS 616:2017/ Oven with humidity


parts IEC 60065 : 2014 Cl.13.7, Chamber: Temp: up
Cl.13.8 to 80deg/
Humidity: up to 98% /
AC-DC withstanding
voltage: up to 5 KV/
Vernier: 150mm/

Micrometer: up to
25mm
Terminals IS 616:2017/ Qualitative
IEC 60065 : 2014 Cl.15
Plug & Sockets IS 616:2017/ Vernier: up to
IEC 60065 : 2014 Cl.15.1, 150/mm
Cl.15.1.1, Cl.15.1.2, Cl.15.1.3 Micrometer: up to
25/0.001 mm
Provisions for protective IS 616:2017/ Micrometer: 0-25/
earthing IEC 60065 : 2014 Cl.15.2
ECRT: 0-12/ 0.01 V
Stop Watch:
99.9min./0.01sec.
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC

Terminals for external IS 616:2017/ Vernier: upto


flexible cords and for IEC 60065 : 2014 Cl.15.3, 150mm
permanent connection to Cl.15.3.1, Cl.15.3.2, Cl.15.3.3, mm Push Pull :

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 83 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
the mains Cl.15.3.4, Cl.15.3.5, Cl.15.3.6, 1000N/
Cl.15.3.7, Cl.15.3.8, Cl.15.3.9 Micrometer: upto
25mm
Device forming a part of IS 616:2017/ Device forming test
the mains plug IEC 60065 : 2014 Cl. 15.4, Cl. apparatus.
15.4.1, Cl. 15.4.2, Cl. 15.4.3 Torque: 0.02-6
Nm/
Vernier: upto
150mm
Drop Test apparatus,
PAES: 0-70V
Test Probe B, Stop
Watch:
99.9min./0.01sec.
Push Pull:
1000N/
Oven with humidity
Chamber: Temp: up
to 80deg/
Humidity: up to 98%

External flexible cord IS 616:2017/ Micrometer: upto


IEC 60065 : 2014 Cl: 16, 25mm/
Cl.16.1, Cl.16.2, Cl.16.3, AC-DC withstanding
Cl.16.4, Cl.16.5, Cl.16.6, voltage: up to 5 KV/
Cl.16.7 Metal Foil Paper
less recorder

upto 1100deg.
/0.1deg

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 84 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Cord Flexing
Stop Watch:
99.9min./0.01sec.
Torque: 0.02-6 Nm

Vernier: upto
150mm
Electric connection and IS 616:2017/ Micrometer: upto
Mechanical Fixing IEC 60065 : 2014 Cl.17, 25mm/
Cl.17.1 Vernier: upto
150mm/
Torque: 0.02-6
Nm
IS 616:2017/ Qualitative
IEC 60065 : 2014 Cl.17.2
IS 616:2017/ Torque: 0.02-6
IEC 60065 : 2014 Cl.17.3 Nm
IS 616:2017/ Qualitative
IEC 60065 : 2014
Cl.17.4,Cl.17.5, Cl.17.6
IS 616:2017/ Vernier: upto
IEC 60065 : 2014 150mm
Cl.17.7,Cl.17.8, Cl.17.9 Micrometer: upto
25/0.001 mm
Torque: 0.02-6
Nm/
Push Pull:
1000N/LC:0.1N
PAES: 0-70V/
Test Probe 11,
Stop Watch:
99.9min./0.01sec.,
Test Probe B, Test

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 85 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Hook.
Mechanical IS 616:2017/ Qualitative
IEC 60065 : 2014 Cl.18
Stability and mechanical IS 616:2017/ Qualitative
hazards IEC 60065 : 2014 Cl.19
Stability requirements IS 616:2017/ Weighing Balance:
IEC 60065 : 2014 Cl.19.1 upto 50kg/0.01Kg
Measuring Tape:
upto5mtrs.
Test at 10° to the IS 616:2017/ Inclined plain 10 o
horizontal IEC 60065 : 2014 Cl.19.2 Measuring Tape:
upto5mtrs.
Vertical force test IS 616:2017/ Angle Finder: 360º
IEC 60065 : 2014 Cl.19.3
Push
Pull1000N
Measuring Tape:
upto 5mtrs.
Horizontal force test IS 616:2017/ Weight: upto 100 kg
IEC 60065 : 2014 Cl.19.4 Measuring Tape:
upto 5mtrs
Push Pull.
1000N/
Angle Finder: 360º
Test of edges and IS 616:2017/ Qualitative
corners IEC 60065 : 2014 Cl.19.5
Mechanical strength of IS 616:2017/ Qualitative
glass IEC 60065 : 2014 Cl.19.6
Requirements IS 616:2017/ Impact: up to 3.5 J
IEC 60065 : 2014 Cl.19.6.1 Vernier: upto
150mm/0.01 mm
Scale: upto 300/0.5

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 86 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
mm
Measuring Tape:
upto 5mtrs.
Weighing Balance:
upto 50kg/5gm
Fragmentation test IS 616:2017/ Vernier: upto
IEC 60065 : 2014 150mm/0.01 mm
Cl.19.6.2 , Stop Watch:
99.9min./0.01sec.,
Wall or ceiling mounting IS 616:2017/ Qualitative
means IEC 60065 : 2014
Cl.19.7
Requirements& Test IS 616:2017/ Stop Watch:
Method IEC 60065 : 2014 99.9min./0.01sec.,
Cl.19.7.1, Cl.19.7.2, Cl.19.7.3 Weight: As per
standard
requirements.
Torque: 0.02-6
Nm
Resistance to fire IS 616:2017/ Qualitative
IEC 60065 : 2014
Cl.20
Requirements IS 616:2017 Qualitative
/IEC 60065 : 2014
Cl.20.1
Electrical components IS 616:2017/ Paper less recorder
and mechanical parts IEC 60065 : 2014 (Temperature data
Cl.20.2, Cl.20.2.1, Cl.20.2.2, logger): up to
Cl.20.2.3, Cl.20.2.4, Cl.20.2.5 1100deg. /0.1deg
Vernier: upto
150mm/0.01mm
Micrometer: upto
25/0.001mm

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 87 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Stop Watch:
99.9min./0.01sec
Fire Enclosure IS 616:2017/IEC 60065 : 2014 Paper less recorder
Cl.20.3, Cl.20.3.1, Cl.20.3.2, (Temperature data
Cl.20.3.3, logger): up to
1100deg. /0.1deg
Vernier: upto
150/0.01mm
Micrometer: upto
25/0.001mm
Stop Watch:
99.9min./0.01sec
Needle Flame Test
Apparatus.
II. INFORMATION TECHNOLOGY EQUIPMENT

1. Information General Condition for IS 13252 (Part-1) Cl.1.4. Qualitative


Technology test
Equipment safety, Application of test IS 13252 (Part-1) Cl.1.4.1 Qualitative
Part – 1 : General Type Test IS 13252 (Part-1) Cl.1.4.2 Qualitative
Requirements Test Samples IS 13252 (Part-1) Cl.1.4.3 Qualitative
Operating parameters IS 13252 (Part-1) Cl.1.4.4 Qualitative
IS 13252 (Part- for test
1):2010+A1:2013 Supply Voltage & IS 13252 (Part-1) Cl.1.4.5 & Multi Test Panel:
A2:2015/IEC Supply frequency Cl.1.4.6 Voltage: up to
60950-1 : 2005 300Volt/
+A1-2009+A2- Current: 30A/
2013
Power: 9 kW
Power Analyzer: up
to 500V/
up to 10A/Up to
1000/0.1 W , Up to

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 88 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
500/0.001 V , up to 5/
0.001 A , Up to 1000
W/
1Wat Dimmer :
up to 300V
Measurement of Voltage IS 13252 (Part-1) Multi meter : Voltage
to earth Cl.1.4.9 up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
Resistor: 5000Ω
Multi Test Panel:
Voltage: up to
300Volt/
Current: 30A/
Power: 9 kW

Loading configuration of IS 13252 (Part-1) Multi Test Panel:


EUT & Power from a Cl.1.4.10 & Cl.1.4.11 Voltage: up to
telecommunication 300Volt/
network Current: 30A/
Power: 9 kW
Power Analyzer: up
to 500V/
up to 10A/
Up to 1000/0.1 W ,
Up to 500/0.001 V ,
up to 5/ 0.001 A , Up
to 1000 W

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 89 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Dimmer : up to 300V
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC,
DC electronic load:
LV: up to 15V
DC/0.001V DC, HV:
up to 150V
DC/0.01VDC, Low
current: up to
2.1A/0,1mA, Middle
current: up to
21A/0.001A DC, High
current: 210A/0.01A
DC
Rheostate: 20Ω/9A
Temperature IS 13252 (Part-1) Qualitative
measurement conditions Cl.1.4.12, Cl.1.4.12.1,
Cl.1.4.12.2, Cl.1.4.12.3,
Temperature rise of a IS 13252 (Part-1) Dry-Wet
winding Cl.1.4.13 Thermometer: -10°C
& Annex E to +50 °C
ii)Micro Ohm Meter:
20µΩ to 20KΩ/
Paper less recorder
(Temperature data
logger): up to
1100deg. /0.1deg

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 90 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Simulated faults and IS 13252 (Part-1) Qualitative
abnormal conditions C1.4.14
Compliance by IS 13252 (Part-1) Qualitative
inspection of relevant C1.4.15
data
Components IS 13252 (Part-1) N.A.
Cl.1.5
Double or Reinforced IS 13252 (Part-1) N.A.
Insulation Bridged by Cl.1.5.7.3, Cl.2.4.2
components
Power interface IS 13252 (Part-1) Cl.1.6 Qualitative

AC Power Distribution IS 13252 (Part-1) Cl.1.6.1 Qualitative


System
Input Test IS 13252 (Part-1) Cl.1.6.2 Power Analyzer: up
to 500V/
up to 10A/
Up to 1000/0.1 W ,
Up to 500/0.001 V ,
up to 5/ 0.001 A , Up
to 1000 W/
Dimmer : up to 300V
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
DC electronic load:
LV: up to 15V
DC/0.001V DC, HV:
up to 150V

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 91 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
DC/0.01VDC, Low
current: up to
2.1A/0,1mA, Middle
current: up to
21A/0.001A DC, High
current: 210A/0.01A
DC
Rheostate: 20Ω/9A
Voltage limit of hand- IS 13252 (Part-1) Cl.1.6.3 Qualitative
held Equipment
Neutral Conductor IS 13252 (Part-1) Cl.1.6.4 Qualitative

Marking and IS 13252 (Part-1) Qualitative


instructions, Cl.1.7, Cl.1.7.1, Cl.1.7.2,
Power Rating, Cl.1.7.2.1, Cl.1.7.2.2,
Safety Instruction and Cl.1.7.2.3, Cl.1.7.2.4,
marking, Cl.1.7.2.5, Cl.1.7.2.6, Cl.1.7.3,
Short duty cycle, Cl.1.7.4, Cl.1.7.5 & Cl.1.7.6
Supply Voltage
Adjustment,
Power outlets on the
equipment & Fuse
Identification
Wiring Terminals, IS 13252 (Part-1) Qualitative
Controls and Indicators, Cl.1.7.7, Cl.1.7.7.1, Cl.1.7.7.2,
Isolation of multiple Cl.1.7.7.3,Cl.1.7.8, Cl.1.7.8.1,
power source, & Cl.1.7.8.2, Cl.1.7.8.3,
Thermostats and other Cl.1.7.8.4,Cl.1.7.9,Cl.1.7.10
regulating devices.
Durability IS 13252 (Part-1) Petroleum spirit,
Cl.1.7.11 Water, Cotton Cloth
Stop Watch:
99.9min./0.01sce

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 92 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed

Removable parts, IS 13252 (Part-1) Qualitative


Replaceable Batteries & Cl.1.7.12, Cl.1.7.13,& Cl.1.7.14
Equipment for Restricted
access location.
Protection from Hazards IS 13252 (Part-1) Qualitative
Cl. 2
Protection from electric IS 13252 (Part-1) Qualitative
shock and energy Cl.2.1
hazards
Protection in operator IS 13252 (Part-1) PAES: 0-70V
access areas & Access Cl.2.1.1 & Cl.2.1.1.1
Test Probe B, Test
to energized parts
Probe 13, Test
Probe: As per fig. 2C,
Test fig. 2D,
Vernier: 0-150
mm
Micrometer: 0-25
mm/LC0.001mm
AC-DC withstanding
voltage: up to 5 kV/
Stop Watch:
99.9min./0.01sec.
Metail foil
Push Pull: Force:
1000N
Battery Compartments IS 13252 (Part-1) Cl.2.1.1.2 Qualitative
Access to ELV wiring & IS 13252 (Part-1) Cl.2.1.1.3 & Vernier: 0-150
Access to hazards Cl.2.1.1.4 mm
voltage circuit wiring Micrometer: 0-25 mm
AC-DC withstanding

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 93 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
voltage: up to 5 kV

Stop Watch:
99.9min./0.01sec.
Metail foil
Energy hazards IS 13252 (Part-1) Cl.2.1.1.5 Rheostate: 20Ω/9A
PAES: 0 to 70V/
Test Probe B
Stop Watch:
99.9min./0.01sec
LCR Meter: 1nF to
200 µF
Manual Controls IS 13252 (Part-1) Cl.2.1.1.6 AC-DC withstanding
voltage: up to 5 kV/
Stop Watch:
99.9min./0.01sec.
Metail foil
Discharge of capacitors IS 13252 (Part-1) Digital Storage
in Equipment Cl.2.1.1.7 Oscilloscope:
Voltage: up to 300V,
Resistance: 1 MΩ,
100 MHz/100MΩ in
parallel with 20pF
Stop Watch:
99.9min./0.01sec.
1nF – 200 µF.
Meter
Energy hazards d.c. IS 13252 (Part-1) Digital Storage
mains supply Cl.2.1.1.8 Oscilloscope:
Voltage: up to 300V,
Resistance: 1 MΩ,

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 94 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
100 MHz/100MΩ in
parallel with 20pF

Stop Watch:
99.9min./0.01sec
LCR Meter: 1nF –
200 µF
Audio amplifier in IS 13252 (Part-1) PAES: 0-70V/LC 0.1V
information technology Cl.2.1.1.9 Test Probe B, Test
equipment Probe 13, Test Probe:
As per fig. 2C, Test
fig. 2D,
Vernier: 0 to 150
mm
Micrometer: 0-25
mm/
AC-DC withstanding
voltage: up to 5 kV/
Stop Watch:
99.9min./0.01sec.
Metail foil
Push Pull Force:
1000N
AC Supply: up to 300
Volt/LC 1 Volt
Leakage current
Tester: 25V/,
Current: up to
20mA/0.001µA
Touch Current
measurement test
circuit: 0- 70 mA
200mV

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 95 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Miultimeter : Voltage
up to 600V/0.001V
AC, up to

600V/0.001V DC,
Current: up to
10A/0.001A
AC and DC
Protection in service IS 13252 (Part-1) Digital Storage
access areas & Cl.2.1.2 & Cl.2.1.3 Oscilloscope:
Protection in restricted Voltage: up to 300V,
access locations Resistance: 1 MΩ,
100 MHz/100MΩ in
parallel with 20pF
Stop Watch:
99.9min./0.01sec.
LCR Meter:1nF to
200 µF
Test Probe B.
SELV Circuits IS 13252 (Part-1) Miultimeter : Voltage
Cl.2.2, Cl.2.2.1, Cl.2.2.2, up to 600V/0.001V
Cl.2.2.3, & Cl.2.2.4 AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
Stop Watch:
99.9min./0.01sec.
TNV Circuits IS 13252 (Part-1) Qualitative
Cl.2.3,Cl.2.3.1, Cl.2.3.2,
Cl.2.3.2.1, Cl.2.3.2.2,
Cl.2.3.2.3, Cl.2.3.2.4,
Cl.2.3.3,Cl.2.3.4,& Cl.2.3.5
Limited Current circuits IS 13252 (Part-1) Miultimeter :

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 96 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Cl.2.4, Cl.2.4.1, Cl.2.4.2, & Voltage upto
Cl.2.4.3, 600V/0.001V AC, up
to 600V/0.001V DC,
Current: up to 10A/
0.001A AC and DC
Resistance: 2000 Ω
Power Analyzer: up
to 500V
up to 10A/
Up to 1000/0.1 W ,
Up to 500/0.001 V ,
up to 5/ 0.001 A , Up
to 1000 W
Dimmer : up to 300V
DC electronic load:
LV: up to 15V
DC/0.001V DC, HV:
up to 150V
DC/0.01VDC, Low
current: up to
2.1A/0,1mA, Middle
current: up to
21A/0.001A DC, High
current: 210A/0.01A
DC
Digital Storage
Oscilloscope:
Voltage: up to 300V,
Resistance: 1 MΩ,
100 MHz/100MΩ in
parallel with 20pF
Limited power sources IS 13252 (Part-1) Power Analyzer: up
Cl.2.5, to 500V/

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 97 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Upto 10A/
Upto 1000/0.1 W ,
Upto 500/0.001 V ,
upto 5/ 0.001 A , Up

to 1000 W/
Dimmer : up to 300V
Rheostat: 20Ω/9A
Miultimeter : Voltage
upto 600V/0.001V
AC, upto
600V/0.001V DC,
Current: upto
10A/0.001A AC and
DC
Stop Watch:
99.9min./0.01sec
Provisions for Earthing IS 13252 (Part-1) Micrometer: 0-
and Bonding Cl.2.6, 25/0.01mm
ECRT: 0-200AAmp/

0-12V/ LC 0.01 V
Miultimeter : Voltage
up to 600V/0.001V
AC, upto
600V/0.001V DC,
Current: upto
10A/0.001A AC and
DC
Stop Watch:
99.9min./0.01sec
Protective Earthing. IS 13252 (Part-1) Qualitative
Cl.2.6.1

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 98 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Functional Earthing IS 13252 (Part-1) Qualitative
Cl.2.6.2
Protective Earthing IS 13252 (Part-1) ECRT: 0 to
Conductor and Cl.2.6.3, Cl.2.6.3.1, Cl.2.6.3.2, 200AAmp/
protective bonding Cl.2.6.3.3, Cl.2.6.3.4,
conductor Cl.2.6.3.5 0 to 12V
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
Stop Watch:
99.9min./0.01sec
Terminals IS 13252 (Part-1) Qualitative
Cl.2.6.4
General IS 13252 (Part-1) Micrometer: 0 to
Cl.2.6.4.1, Cl.2.6.4.2, 25mm
Cl.2.6.4.3, Torque: 0.02 to
6/0.01,
upto 12cNm/0.5cNm
Integrity of protective IS 13252 (Part-1) Qualitative
Earthing Cl.2.6.5, Cl.2.6.5.1, Cl.2.6.5.2,
Cl.2.6.5.3, Cl.2.6.5.4,
Cl.2.6.5.5, Cl.2.6.5.6,
Cl.2.6.5.7, & Cl.2.6.5.8
Over Current and Earth IS 13252 (Part-1) Cl.2.7 Qualitative
fault protection in
primary circuits
Basic Requirements IS 13252 (Part-1) Cl.2.7.1 Qualitative
Faults Not simulated in IS 13252 (Part-1) Cl.2.7.2 Qualitative
5.3.7

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 99 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed

Short-circuit backup IS 13252 (Part-1) Cl.2.7.3 Miultimeter : Voltage


protection up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A
AC and DC
Number and location of IS 13252 (Part-1) Cl.2.7.4 Miultimeter : Voltage
protective device upto 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A
AC and DC
Protection by several IS 13252 (Part-1) Cl.2.7.5 Qualitative
devices
Warning To Service IS 13252 (Part-1) Cl.2.7.6 Qualitative
person
Safety Interlocks IS 13252 (Part-1) Cl.2.8 & Qualitative
&General Principles Cl.2.8.1
Protection Requirements IS 13252 (Part-1) Cl.2.8.2 PAES: 0 to 70V
Test Probe B
Inadvertent reactivation IS 13252 (Part-1) Cl.2.8.3 PAES: 0 to 70V
Test Probe B
Fail-safe IS 13252 (Part-1) Cl.2.8.4 Qualitative
Moving Parts IS 13252 (Part-1) Cl.2.8.5 Count:10000cycles/

Overriding IS 13252 (Part-1) Cl.2.8.6 Qualitative


Switches and relays IS 13252 (Part-1) Cl.2.8.7 10000 cycles & upto
40 amp

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 100 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Contact Gaps IS 13252 (Part-1) Cl.2.8.7.1 Vernier: 0 to 150
mm
Over Load Test IS 13252 (Part-1) Cl.2.8.7.2 999999 cycles/LC 1
Cycle, Upto
40Amp
Endurance Test IS 13252 (Part-1) Cl.2.8.7.3 999999 cycles/
Upto 40Amp/
Electric Strength Test IS 13252 (Part-1) Cl.2.8.7.4 AC-DC withstanding
voltage: up to 5 kV/

Mechanical actuators IS 13252 (Part-1) Cl.2.8.8 Vernier: 0 to 150


mm
Electric insulation IS 13252 (Part-1) Cl.2.9 Qualitative
Properties of Insulating IS 13252 (Part-1) Cl.2.9.1 & Humidity Chamber:
materials, Humidity Cl.2.9.2 Temp: up to 60
Conditioning. deg., RH.
upto 98%
AC-DC withstanding
voltage: up to 5 kV/
Grade of insulation IS 13252 (Part-1) Cl.2.9.3 Qualitative
Separation from IS 13252 (Part-1) Cl.2.9.4 Qualitative
Hazardous voltages
Clearances, Creepage IS 13252 (Part-1) Cl.2.10 Qualitative
distance and distance
through insulation
General IS 13252 (Part-1) Cl.2.10.1 Qualitative
Frequency IS 13252 (Part-1) Cl. 2.10.1.1 Digital Storage
Oscilloscope:
Voltage: up to 300V,
Resistance: 1 MΩ,
100 MHz
Pollution Degrees IS 13252 (Part-1) Cl.2.10.1.2 Qualitative

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 101 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Reduced values for IS 13252 (Part-1) Cl.2.10.1.3, Vernier: 0 to 150
functional insulation, Cl.2.10.1.4, Cl.2.10.1.5, mm
Intervening unconnected Cl.2.10.1.6 &
conductive parts, Cl.2.10.1.7
Insulation with varying
dimensions,
Special Separation

Requirements,
Insulation in Circuit
generating starting
pulses,
& Annex F
Determination of working IS 13252 (Part-1) Multi Test Panel:
voltage Cl.2.10.2 Voltage: up to
300Volt/
Current: 30A/
Power: 9 kW
Digital Storage
Oscilloscope:
Voltage: up to 300V,
Resistance: 1 MΩ,
100 MHz
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A
AC and DC
DC electronic load:
LV: up to 15V
DC/0.001V DC, HV:

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 102 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
up to 150V
DC/0.01VDC, Low
current: up to
2.1A/0,1mA, Middle
current: up to
21A/0.001A DC, High
current:

210A/0.01A DC
General IS 13252 (Part-1) Multi Test Panel:
Cl.2.10.2.1 Voltage: up to
300Volt ,
Current: 30A/
Power: 9 kW
Digital Storage
Oscilloscope:
Voltage: up to 300V,
Resistance: 1 MΩ,
100 MHz
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
DC electronic load:
LV: up to 15V
DC/0.001V DC, HV:
up to 150V
DC/0.01VDC, Low
current: up to

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 103 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
2.1A/0,1mA, Middle
current: up to
21A/0.001A DC,
High current:
210A/0.01A DC

RMS Working Voltage & IS 13252 (Part-1) Cl.2.10.2.2 Multi Test Panel:
Peak Working Voltage & Cl.2.10.2.3 Voltage: up to
300Volt/LC 0.1Volt ,
Current: 30A
Power: 9 kW
Digital Storage
Oscilloscope:
Voltage: up to 300V,
Resistance: 1 MΩ,
100 MHz
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
DC electronic load:
LV: up to 15V
DC/0.001V DC,
HV: up to 150V
DC/0.01VDC, Low
current: up to
2.1A/0,1mA, Middle
current: up to
21A/0.001A DC, High

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 104 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
current: 210A/0.01A
DC
Clearances & General IS 13252 (Part-1) Cl.2.10.3 & Vernier: 0 to 150
2.10.3.1 mm/LC 0.01mm
Digital Storage
Oscilloscope:
Voltage: up to 300V,

Resistance: 1 MΩ,
100 MHz
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
Mains Transient IS 13252 (Part-1) 2.10.3.2 Qualitative
Voltages
Clearances in primary IS 13252 (Part-1) Cl.2.10.3.3 Vernier: 0-150
circuits & Cl. 2.10.3.4 mm/
& Digital Storage
Clearances in Oscilloscope:
Secondary circuits Voltage: up to 300V,
Resistance: 1 MΩ,
100 MHz
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A
AC and DC

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 105 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Clearances in circuits IS 13252 (Part-1) 2.10.3.5 Vernier: 0-150
having starting pulses mm/
Digital Storage
Oscilloscope:
Voltage: up to 300V,
Resistance: 1 MΩ,
100 MHz
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A
AC and DC
AC-DC withstanding
voltage: up to 5 KV/

Transient from an a.c. IS 13252 (Part-1) Cl.2.10.3.6, Vernier: 0-150


and d.c. mains supply Cl. 2.10.3.7, Cl.2.10.3.8, mm/
And transient from Digital Storage
telecommunication Oscilloscope:
Network and cable Voltage: up to 300V,
distribution system Resistance: 1 MΩ,
100 MHz
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A
AC and DC
AC-DC withstanding
voltage: up to 5 KV/

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 106 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Measurement of IS 13252 (Part-1) Cl. 2.10.3.9 Digital Storage
transient voltages Oscilloscope:
Voltage: up to 300V,
Resistance: 1 MΩ,
100 MHz
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to

10A/0.001A
AC and DC
AC-DC withstanding
voltage: up to 5 kV/
Impulse: 1.2/50 µS
upto 10kV
Creepage Distances , IS 13252 (Part-1) Tracking Volt: upto
General, Material group Cl.2.10.4 , Cl.2.10.4.1, 600 & 6A
& Comparative tracking Cl.2.10.4.2 , Vernier: 0 to 150
Index mm
Test Probe B
Minimum Creepage IS 13252 (Part-1) Vernier: 0-150
Distances Cl.2.10.4.3 mm
Digital Storage
Oscilloscope:
Voltage: up to 300V,
Resistance: 1 MΩ,
100 MHz
Miultimeter : Voltage
up to 600V/0.001V
AC, upto600V/
0.001V DC,

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 107 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Current: up to 10A/
0.001A AC and DC
Test Probe B
Solid Insulation IS 13252 (Part-1) Vernier: 0-150
Cl.2.10.5 & Cl.2.10.5.1 mm
Digital Storage
Oscilloscope:
Voltage: up to 300V,
Resistance: 1 MΩ,
100 MHz

Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A
AC and DC
AC-DC withstanding
voltage: up to 5 kV
Distance through IS 13252 (Part-1) Vernier: 0-150
Insulation, Insulating Cl.2.10.5.2, Cl.2.10.5.3, mm/
Compound and solid Cl.2.10.5.4 & Cl.2.10.5.5 Digital Storage
Insulation, Oscilloscope:
Semiconductor devices, Voltage: up to 300V,
Cemented Joints Resistance: 1 MΩ,
100 MHz
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 108 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
DC
AC-DC withstanding
voltage: up to 5 kV/

Thin Sheet Material, IS 13252 (Part-1) AC-DC withstanding


Separable thin Sheet Cl.2.10.5.6, Cl.2.10.5.7, voltage: up to 5 kV/
Material, Non Separable Cl.2.10.5.8 , Cl.2.10.5.9, &
thin sheet material, Thin Cl.2.10.5.10
sheet material
Insulation in wound IS 13252 (Part-1) Vernier: 0 to 150
components, Wire in Cl.2.10.5.11, Cl.2.10.5.12, mm
wound components, wire Cl.2.10.5.13, & Cl.2.10.5.14 Digital Storage
with solvent based Oscilloscope:
enamel in wound Voltage: up to 300V,
components,& Additional Resistance: 1 MΩ,
Insulation in wound 100 MHz
components Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
AC-DC withstanding
voltage: up to 5 kV/
Micrometer: upto
25/0.001 mm
Construction of printed IS 13252 (Part-1) Vernier: 0-150
boards, Uncoated Cl.2.10.6, Cl.2.10.6.1, mm
printed boards, Coated Cl.2.10.6.2, Cl.2.10.6.3, & Digital Storage
printed boards, Cl.2.10.6.4, Oscilloscope:
Insulation Between Voltage: up to 300V,
conductors on same Resistance: 1 MΩ,

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 109 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
inner pand different 100 MHz
surface o f a printed Miultimeter : Voltage
board. up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
AC-DC withstanding
voltage: up to 5 kV

Component external IS 13252 (Part-1) Vernier: 0 to 150


terminations Cl.2.10.7 mm/LC 0.01mm
Oscilloscope: Up to
100 MHz
Voltmeter: Up to
1000 Volt DC & AC
AC Volt: 0-5kV
Temp.: (-)45ºC to
175 ºC
Abrasion: tip angle
400,Tip radius
0.25±0.02mm, Speed
of abrasion
20mm/S±5mm/S,
Force 10N±0.5N
Test on coated printed IS 13252 (Part-1) Cl.2.10.8,& Qualitative
boards and coated Cl.2.10.8.1
components & Sample
preparation and
preliminary Inspection
Thermal Conditioning IS 13252 (Part-1) Cl.2.10.8.2 Power Supply: 600V
Environment

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 110 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Conditional
Chamber: Temp.:
(-)20ºC to
Paper less recorder
(Temperature data
logger): up to
1100deg. /0.1deg
Electric Strength test IS 13252 (Part-1) Cl.2.10.8.3 Humidity Chamber:
Temp: up to 60 Deg

RH. upto
98%
AC-DC withstanding
voltage: up to 5 kV

Abrasion resistance test IS 13252 (Part-1) Cl.2.10.8.4 Abrasion: Tip angle


400,Tip radius
0.25±0.02mm,Speed
of abrasion
20mm/S±5mm/S,
Force 10N±0.5N
AC-DC withstanding
voltage: up to 5 kV/
Vernier: 0-150
mm
Thermal conditioning IS 13252 (Part-1) Environment
Cl.2.10.9 Conditional
Chamber: Temp.:
(-)20 ºC to 90 ºC

Test for pollution degree IS 13252 (Part-1) Environment


1 environment and for Cl.2.10.10 Conditional

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 111 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
insulating compound Chamber: Temp.:
(-)20 ºC to 90 ºC
Humidity Chamber:
Temp: up to 60
deg,RH.
upto 98
AC-DC withstanding
voltage: up to 5 kV/
LC 0.001kV

Test for semiconductor IS 13252 (Part-1) Environment


devices and for Cl.2.10.11 Conditional Chamber:
cemented joints Temp.:(-)20 ºC to
90 ºC
Humidity Chamber:
Temp: up to 60
deg. ,RH. upto
98%/LC:1%
AC-DC withstanding
voltage: upto 5 kV/

Enclosed and sealed IS 13252 (Part-1) Environment


parts Cl.2.10.12 Conditional
Chamber: Temp.:
(-)20 ºC to 90 ºC /
Humidity Chamber:
Temp: up to 60
deg,RH. upto
98%/LC:1%
AC-DC withstanding
voltage: up to 5 kV/

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 112 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Wiring, connections, and IS 13252 (Part-1) Miultimeter : Voltage
supply, General, & Cl.3, Cl.3.1, Cl.3.1.1 up to 600V/0.001V
Current rating and over AC, up to
current protection. 600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC,
Paper less recorder
(Temperature data
logger): up to
1100deg. /0.1deg

Protection against IS 13252 (Part-1) Qualitative


mechanical damage & Cl.3.1.2, & Cl.3.1.3
Securing of internal
wiring
Insulation of conductors IS 13252 (Part-1) AC-DC withstanding
Cl.3.1.4 voltage: up to 5 kV/
Measuring Tape:
upto 5meter/
Metal Foil.
Beads and ceramic IS 13252 (Part-1) Push Pull: Force:
insulators Cl.3.1.5 1000N
Screws for electrical IS 13252 (Part-1) Qualitative
connection, Insulation Cl.3.1.6, Cl.3.1.7,& Cl.3.1.8
material in electrical
connections, self-tapping
and spaced thread
screw
Termination of IS 13252 (Part-1) Push Pull : Force:
conductors Cl.3.1.9 1000N
Vernier: 0-150
mm

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 113 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Sleeving on wiring IS 13252 (Part-1) Qualitative
Cl.3.1.10
Connection to a.c. & d.c. IS 13252 (Part-1) Qualitative
mains supply, Cl3.2, Cl.3.2.1,&
Cl.3.2..1.1,Cl.3.2.1.2
Multiple supply IS 13252 (Part-1) PAES: 0-70V
connections Cl.3.2.2
Test Probe B
Permanently connected IS 13252 (Part-1) Vernier:upto 150mm/
equipment Cl.3.2.3
Micrometer: upto 25/
0.001 mm

Appliance inlets IS 13252 (Part-1) PAES: 0-


Cl.3.2.4 70V/
Test Probe B
A.C. & D.C. Power IS 13252 (Part-1) Counter: up to
supply cords Cl.3.2.5, Cl.3.2.5.1, Cl.3.2.5.2 999999 count/
upto 150/0.01 mm
Micrometer: upto 25/
0.001 mm
Vernier: upto
150mm/
AC-DC withstanding
voltage: up to 5 kV/
Cord anchorages and IS 13252 (Part-1) Push Pull: Force:
strain relief Test Cl.3.2.6 upto 100N
Vernire: upto 150/
0.01 mm
Stop Watch:
99.9min./0.01sec
Protection against IS 13252 (Part-1) Vernire: upto 150/
mechanical damage Cl3.2.7 0.01 mm
Micrometer: upto 25/

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 114 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
0.001 mm
Cord guards IS 13252 (Part-1) Vernire: upto
Cl.3.2.8 150/0.01 mm
Micrometer: upto 25/
0.001 mm
Supply wiring spaces IS 13252 (Part-1) Vernire: upto 150/
Cl.3.2.9 0.01 mm
Micrometer: upto 25/
0.001 mm

Wiring terminals for IS 13252 (Part-1) Qualitative


connection of external Cl.3.3
conductor
Wiring Terminals, IS 13252 (Part-1) Paper less recorder
Connections to non- Cl.3.3.1, Cl.3.3.2, Cl.3.3.3 (Temperature data
detachable power supply logger): up to
cords, 1100deg. /0.1deg
Screw Terminals Multi Test Panel:
Voltage: up to
300Volt/
Current: 30A/
Power: 9 kW

Power Analyzer: up
to 500V
up to 10A/
Up to 1000/0.1 W ,
Up to 500/0.001 V ,
up to 5/ 0.001 A ,
Up to 1000 W/

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 115 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Dimmer : up to 300V
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC,
DC electronic load:
LV: up to 15V
DC/0.001V DC, HV:
up to 150V

DC/0.01VDC, Low
current: up to
2.1A/0,1mA, Middle
current: up to
21A/0.001A DC, High
current: 210A/0.01A
DC
Rheostat: 20Ω/9A

Conductor sizes to be IS 13252 (Part-1) Vernire: upto


connected Cl.3.3.4 150/0.01 mm
Micrometer: 25
Wiring terminal sizes, IS 13252 (Part-1) Vernire: upto
Wiring terminal design , Cl.3.3.5, Cl.3.3.6 ,Cl.3.2.7 & 150/0.01 mm
Grouping of wiring Cl.3.3.8 Micrometer: 25
terminals & Stranded
Torque: 1.2Nm
wire
Disconnection from the IS 13252 (Part-1) Qualitative
mains supply, General Cl.3.4, Cl. 3.4.1, Cl. 3.4.2, Cl.
Requirements, 3.4.3, Cl. 3.4.4, Cl. 3.4.5, Cl.

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 116 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Disconnects device, 3.4.6, Cl. 3.4.7, Cl. 3.4.8, Cl.
Permanently connected 3.4.9, Cl. 3.4.10, Cl. 3.4.11
equipment, Parts which
remain energized,
Switches in flexible
cords, Number of poles-
single phase and DC
equipments, Number of
poles- three phase ,
Switches as disconnect
devices, Plugs as
disconnect devices,
Interconnected
equipment, Multiple
power sources
Interconnection of IS 13252 (Part-1) Qualitative
Equipments, General Cl.3.5, Cl.3.5.1, Cl.3.5.2,
Requirements, type of Cl.3.5.3
Interconnection circuits,
ELV circuits as
Interconnection circuits
Data Ports additional IS 13252 (Part-1) Power Analyzer: up
equipments Cl.3.5.4 to 500V
up to 10A/
Up to 1000/0.1 W ,
Up to 500/0.001 V ,
up to 5/ 0.001 A , Up
to 1000 W/
Dimmer : up to 300V
Rheostat: 20Ω/9A
Miultimeter : Voltage
up to 600V/0.001V
AC, up to

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 117 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
Stop Watch:
99.9min./0.01sec
Physical Requirements, IS 13252 (Part-1) Incline: 10 o
Stability Cl.4, Cl.4.1 Weigh balance: up to
50kg/
Push Pull: Force: up
to 1000N/
Vernire: upto
150/0.01 mm
Flat surface: 125mm
X 200mm
Mechanical Strength IS 13252 (Part-1) Push Pull Force:
General, Steady force Cl.4.2, Cl.4.2.1, Cl.4.2.2, 1000N
test for 10N, 30N, 250N. Cl.4.2.3 & Cl.4.2.4 Stop Watch:
99.9min./0.01sec
Test Probe B
Weigh balance: up to
50kg
AC-DC withstanding
voltage: up to 5 kV/
Impact Test IS 13252 (Part-1) Steel Ball: 50 mm,
Cl.4.2.5 Dia.500g
Measuring Tape: up
to 5 meter/1mm
AC-DC withstanding
voltage: up to 5 kV/
PAES:0 to70V/
Test Probe B

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 118 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed

Drop Test IS 13252 (Part-1) Weigh balance: up to


Cl.4.2.6 50kg
Measuring Tape: up
to 5 meter/1mm
AC-DC withstanding
voltage: up to 5 kV/
PAES:0 to 70V/
Test Probe B

Stress relief test IS 13252 (Part-1) Oven: Temp: up to


Cl.4.2.7 250 ºC

AC-DC withstanding
voltage: up to 5 kV/
Test Probe B
Vernier: upto
150/0.01 mm
Cathode ray tubes IS 13252 (Part-1) Qualitative
Cl.4.2.8
High pressure lamps IS 13252 (Part-1) Qualitative
Cl.4.2.9
Wall or ceiling mounted IS 13252 (Part-1) Push Pull: Force:
equipment Cl.4.2.10 1000N
Stop Watch:
99.9min./0.01sec
Weigh balance: up to
50kg
Design & Construction, IS 13252 (Part-1) Push Pull: Force: up
Edges and corner, Cl.4.3, Cl.4.3.1, Cl.4.3.2 to 1000N
Handles and manual Stop Watch:
controls. 99.9min./0.01sec

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 119 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed

Adjustable controls, IS 13252 (Part-1) Qualitative


Securing of parts & Cl.4.3.3,Cl.4.3.4 & Cl.4.3.5
Connection by the plug
and sockets.
Direct plug-in equipment IS 13252 (Part-1) Torque: 1.2Nm
Cl.4.3.6
Heating elements in IS 13252 (Part-1) Test Probe B,
earthed equipment Cl.4.3.7, Cl.4.3.8, Cl.4.3.9, Charging and
Batteries, Cl.4.3.10, Cl.4.3.11, Cl.4.3.12 discharging: upto:
Oil and grease 22V/0.01V, upto:
Dust, powder, liquids 10A
and gases AC-DC withstanding
Containers for liquids or voltage: up to 5 kV/
gases Flammable liquids
Radiation IS 13252 (Part-1) Qualitative
Cl.4.3.13, Cl.4.3.13.1
Ionizing radiation IS 13252 (Part-1) Qualitative
& Annex H Cl.4.3.13.2
Effect of ultraviolet IS 13252 (Part-1) Qualitative
radiation on materials Cl.4.3.13.3
Human Exposure to uv IS 13252 (Part-1) Qualitative
and Lesers Cl.4.3.13.4 an cl.4.3.13.5
Protection against IS 13252 (Part-1) Test Probe B, Push
Hazardous Moving Parts Cl.4.4, Cl. 4.4.1, Cl. 4.4.2, Cl. Pull: Force: 1000N
4.4.3, Cl. 4.4.4
Thermal Requirements, IS 13252 (Part-1) Paper less recorder
General, Cl.4.5, Cl.4.5.1, Cl.4.5.2, (Temperature data
Temperature Test, Cl.4.5.3, Cl.4.5.4 logger): up to
Temperature limits for 1100deg. /0.1deg
Materials, Multi Test Panel:

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 120 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Touch Temperature Voltage: up to
Limits. 300Volt/ ,
Current: 30A
Power: 9 kW
Power Analyzer: up
to 500V/
up to 10A/,
Up to 1000/0.1 W ,
Up to 500/0.001 V ,
up to 5/ 0.001 A ,
Up to 1000 W/
Dimmer : up to 300V
Miultimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC,
DC electronic load:
LV: up to 15V
DC/0.001V DC, HV:
up to 150V
DC/0.01VDC, Low
current: up to
2.1A/0,1mA, Middle
current: up to
21A/0.001A DC, High
current: 210A/0.01A
DC Rheostat:
20Ω/9A
Pink Noise: 1KHz
Micrometer: upto

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 121 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
25mm/LC: 0.001 mm
Resistance to abnormal IS 13252 (Part-1) Ball Pressure
Heat Cl.4.5.5 Instrument:
Force: 5mm Dia /20N
Load
Oven: Temp: up to
250 oC/LC 1oC
Micro Scope
Openings in enclosures IS 13252 (Part-1) Vernire: upto
Cl.4.6,Cl.4.6.1,Cl.4.6.2 & 150mm/LC: 0.01 mm
Cl.4.6.3
Openings in IS 13252 (Part-1) Pin: 1mm
transportable equipment Cl.4.6.4 Dia,100mm Length
Vernire: upto
150mm/
Micrometer: upto
25mm
Adhesives for IS 13252 (Part-1) Temp.: up to 250ºC/
constructional purposes Cl.4.6.5
Temp.: (-)40 ºC
Humidity Chamber:
Temp: up to 60
deg RH.
upto 98%
Resistance to fire IS 13252 (Part-1) Cl.4.7 Qualitative
Reducing the risk of IS 13252 (Part-1) Cl.4.7.1 Temp.: 960/0.1˚C
ignition and spread of Temp.: upto
flame 960/0.1oC
Vernire: upto 150/
0.01 mm
Micrometer: 25

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 122 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Condition for a fire IS 13252 (Part-1)Cl.4.7.2 Qualitative
enclosure
Materials & General IS 13252 (Part-1) Cl.4.7.3 & Temp: 960/0.1˚C
Cl.4.7.3.1
Materials for fire enclosure IS 13252 (Part-1) Cl.4.7.3.2 Temp: 960/0.1˚C
Materials for IS 13252 (Part-1) Cl.4.7.3.3 Temp: up to
components and other 960/0.1oCVernire:
parts outside fire upto 150/0.01 mm
enclosures Micrometer: 25

Material for components IS 13252 (Part-1) Cl.4.7.3.4 Temp: up to


and other parts inside 960/0.1oCVernire:
fire enclosure upto 150/0.01 mm
Micrometer: 25
Materials for air filter IS 13252 (Part-1) Cl.4.7.3.5 Temp: 960/0.1˚C
assemblies
Material used in high- IS 13252 (Part-1) Cl.4.7.3.6 Temp: up to 960/
Voltage Components 0.1 ºC
Electrical Requirements IS 13252 (Part-1) Cl.5, & Leakage current
and simulated abnormal Cl.5.1 Tester: 25V/,
conditions Current: up to
& Touch current and 20mA/0.001µA
protective conductor Touch Current
current measurement test
& Annex D circuit: 0 to 70 mA
200mV,
Miultimeter : Voltage
up to 600V/0.001V
AC, upto 600V/
0.001V DC, Current:
up to 10A/0.001A
AC and DC
DC electronic load:

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 123 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
LV: up to 15V
DC/0.001V DC, HV:
up to 150V
DC/0.01VDC, Low
current: up to
2.1A/0,1mA, Middle
current: up to
21A/0.001A DC, High
current: 210A/0.01A
DC
Rheostat: 20Ω/9A
Electric Strength Test IS 13252 (Part-1) AC-DC withstanding
Cl.5.2 voltage: up to 5 kV/
Stop Watch:
99.9min./
0.01sec
Abnormal Operating and IS 13252 (Part-1) Temp. Indicator: 0-
Fault Conditions & Cl.5.3, Cl.5.3.1 300/ 0.1˚C
Protection against AC Supply: 0-600/
overload and abnormal AC Supply: Upto 600
operation Volt/
Power Meter: 0-270
Timer: 999 minutes/1
sec
Motor IS 13252 (Part-1) DC Source: upto
Cl.5.3.2 & Annex B 150V
Paper less recorder
(Temperature data
logger): up to
1100deg. /0.1deg
Transformer IS 13252 (Part-1) Paper less recorder

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 124 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Cl.5.3.3 & Annex C.1 (Temperature data
logger): up to
1100deg. /0.1deg
DC electronic load:
DC/0.001V DC, HV:
up to 150V
DC/0.01VDC, Low
current: up to
2.1A/0,1mA, Middle
current: up to
21A/0.001A DC, High
current: 210A/0.01A
DC,
Power Analyzer: up
to 500V,
up to 10A/LC: 0.1 A ,
Up to 1000/0.1 W ,
Up to 500/0.001 V ,
up to 5/ 0.001 A , Up
to 1000 W/
Dimmer : up to 300V
Functional Insulation IS 13252 (Part-1) Vernier: upto
Cl.5.3.4 150mm/LC:0.01 mm
Micrometer: 25/

AC Volt: 0 to 5kV
Paper less recorder
(Temperature data
logger): up to
1100deg. /
0.1deg DC
AC-DC withstanding

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 125 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
voltage: up to 5 kV/

Electromechanical IS 13252 (Part-1) Cl.5.3.5 Paper less recorder


Components (Temperature data
logger): up to
1100deg. /0.1deg
Power Analyzer: up
to 500V/
up to 10A,
Up to 1000/0.1 W ,
Up to 500/0.001 V ,
up to 5/ 0.001 A ,
Up to 1000 W

Dimmer : up to 300V
AC-DC withstanding
voltage: up to 5 kV/

Audio Amplifier in IS 13252 (Part-1) Cl.5.3.6 Pink Noise: up to 1


Information Technology KHz
Equipment Power supply: 0-
600

Simulation of Faults IS 13252 (Part-1) Cl.5.3.7 Paper less recorder


(Temperature data
logger): up to
1100deg. /0.1deg
Power supply: 0-
600
Vernier: upto
150/0.01 mm
Micrometer: 25/

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 126 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
AC-DC withstanding
voltage: up to 5 kV/
Unattended Equipment IS 13252 (Part-1) Cl.5.3.8 Paper less recorder
(Temperature data
logger): up to
1100deg. /0.1deg
Power supply: 0-
600/
Vernier: upto
150/0.01 mm
Micrometer: 25
AC-DC withstanding
voltage: up to 5 kV

Compliance criteria for IS 13252 (Part-1) Cl.5.3.9, Vernier: upto


abnormal operating and Cl.5.3.9.1, Cl.5.3.9.2 150/0.01 mm
fault conditions, Micrometer: 25/lc-
During the test, 0.001 mm
After the Test. AC-DC withstanding
voltage: up to 5 kV/

Paper less recorder


(Temperature data
logger): up to
1100deg. /0.1deg
Connection to IS 13252 (Part-1) Cl.6.0 Qualitative
telecommunication
network
Protection of IS 13252 (Part-1) Cl.6.1 Qualitative
telecommunication
network service persons

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 127 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
and users of other
equipment connected to
the network from
hazards in the
equipment
Protection from IS 13252 (Part-1) Cl.6.1.1 Qualitative
hazardous Voltages
Separation of the IS 13252 (Part-1) Cl.6.1.2 & Vernier: upto
telecommunication Cl.6.1.2.1, Cl.6.1.2.2 150/0.01 mm
network from earth AC-DC withstanding
voltage: up to 5 kV/

Protection of equipment IS 13252 (Part-1) Cl.6.2, PAES: 0-


users from over voltages Cl.6.2.1, Cl.6.2.2, Cl.6.2.2.2 & 70V/LC:0.1V
on telecommunication Cl.6.2.2.3 Test Probe B, Test
networks Probe : Fig 2C,
AC-DC withstanding
voltage: up to 5 kV/
Upto 106 MΩ

Impulse test IS 13252 (Part-1) Digital Storage


Cl.6.2.2.1 Oscilloscope:
Voltage: up to 300V,
Resistance: 1 MΩ,
Up to 100 MHz
Impulse: 1.2/50 µS
AC-DC withstanding
voltage: up to 5 kV/

Steady state test and IS 13252 (Part-1) AC-DC withstanding


compliance criteria Cl.6.2.2.2 &cl.6.2.2.3 voltage: up to 5 kV/
Insulation meter:

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 128 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
106MΩ
Protection of the IS 13252 (Part-1) Vernier: upto 150/
telecommunication Cl.6.3 0.01 mm
wiring system from Power Supply:
overheating Voltmeter: Upto 600
Volt AC Rheostat:
20Ω/9A
Multimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A
AC and DC
Connection to cable IS 13252 (Part-1) Vernier: upto 150/
distribution system,& Cl.7,& Cl.7.1 0.01 mm
General Power Supply:
Voltmeter: Up to 600
Volt AC Rheostat:
20Ω/9A
Multimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A
AC and DC
Protection of cable IS 13252 (Part-1) Power Supply:
distribution system Cl.7.2 Voltmeter: Up to 600
service persons, and Volt AC Rheostat:
user of other equipment 20Ω/9A
connected to the system Multimeter:
,from hazardous voltage Voltage up to

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 129 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
in the equipment 600V/0.001V AC, up
to 600V/0.001V DC,
Current: up to
10A/0.001A
AC and DC
Protection of equipment IS 13252 (Part-1) AC-DC withstanding
users from over voltages Cl.7.3 voltage: up to 5 kV/
on the cable distribution
system Up to 106 MΩ
Insulation between IS 13252 (Part-1) AC-DC withstanding
primary circuits and Cl.7.4 & Cl.7.4.1 voltage: up to 5 kV/
cable distribution system
and General I.R.: Up to 106 MΩ
Power Supply:
Voltmeter: Up to 600
Volt AC Rheostat:
20Ω/9A
Multimeter : Voltage
up to 600V/0.001V
AC, up to
600V/0.001V DC,
Current: up to
10A/0.001A AC and
DC
Voltage Surge Test IS 13252 (Part-1) Surge: 10kV, 50
Cl.7.4.2 discharges, 12
pulses /min 1nF
capacitance,
AC-DC withstanding
voltage: up to 5 kV/

Impulse Test IS 13252 (Part-1) Digital Storage


Cl.7.4.3 Oscilloscope:
Voltage: up to 300V,

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 130 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Resistance: 1 MΩ,
Up to 100 MHz
Impulse: 1.2/50 µS

AC-DC withstanding
voltage: up to 5 kV/

III. BATTERIES

1. Secondary Cells Intended use IS 16046 (Part 1)/IEC 62133-1 i) 0 V-10 V


and Batteries Clause No: 7.2, 7.2.1
Containing 0.05A-3 A,
Alkaline or Other ii) up to 999 hrs/
Non-Acid
Electrolytes Vibration IS 16046 (Part 1)/IEC 62133-1 i) 1-2000Hz/1 Hz,
Safety Clause No: 7.2.2 0.1-25mm.0.01 mm
Requirements for ii) upto 999 hrs/
Portable Sealed
Secondary Cells, iii) 0.7V-22 V
and for Batteries
Made from Them, 0.02A-10 A,
for Use in
Portable Case IS 16046 (Part 1)/IEC 62133-1 i) Up to 250°C
Applications. Stress at high Ambient Clause No: 7.2.3
Part 1 Nickel Temperature (batteries) ii) Up to 999 hrs/
System
Temperature Cycling IS 16046 (Part 1)/IEC 62133-1 i) - 40°C to 175°C
IS 16046 (Part Clause No: 7.2.4
ii) 0.7V-22 V
1):2018/IEC 62133-
1:2017 0.02A-10 A

Incorrect Installation IS 16046 (Part 1)/IEC 62133-1 i)upto 300/0.1 ˚C


(cells) Clause No: 7.3.1 ii) 1 Ω
External Short Circuit IS 16046 (Part 1)/IEC 62133-1 i) up to250°C

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 131 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Clause No: 7.3.2
ii) 80±20 mΩ
iii) upto 300/

Free fall IS 16046 (Part 1)/IEC 62133-1 i) 1 mtr Height


Clause No: 7.3.3 ii) qualitative

Mechanical shock IS 16046 (Part 1)/IEC 62133-1 i) Average 75G &


(Crash Hazard) Clause No: 7.3.4 Peak acc. 125G to
175 G
Thermal Abuse IS 16046 (Part 1)/IEC 62133-1 i) up to250/ 1 ˚C
(Cells) Clause No: 7.3.5 5±2°C/min
ii) 1800/0.1 sec
iii) 0.7V to 22 V
0.02A to 10 A

Crushing of cells IS 16046 (Part 1)/IEC 62133-1 i) 15KN


Clause No: 7.3.6
ii) 1 mV to 60V DC
Low Pressure IS 16046 (Part 1)/IEC 62133-1 i) Up to 15kPa
Clause No: 7.3.7
ii) 0.7V to 22 V
0.02A to 10 A,
iii) upto 999 hrs

Overcharge IS 16046 (Part 1)/IEC 62133-1 0.7V-22 V


Clause No: 7.3.8 0.02A to 10 A,

Marking IS 16046 (Part 1)/IEC 62133-1 Qualitative


Clause No: 9

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 132 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
IS 16046 (Part 1)/IEC 62133-1 Qualitative
Cell Marking Clause No: 9.1
IS 16046 (Part 1)/IEC 62133-1 Qualitative
Battery Marking Clause No: 9.2

IS 16046 (Part 1)/IEC 62133-1 Qualitative


Other Information Clause No. 9.4
IV. Secondary Cells Continuous Charging at IS 16046 (Part 2)/IEC 62133-2 i) 0.7V to 22 V
and Batteries constant Voltage (cells) Clause No: 7.2.1
Containing 0.02A to 10 A
Alkaline or Other ii) upto 999 hrs
Non-Acid
Electrolytes Case IS 16046 (Part 2)/IEC 62133-2 i) Up to 250°C
Safety Stress at high Ambient Clause No: 7.2.2
Requirements for Temperature (Battery) ii) upto 999 hrs
Portable Sealed iii) 0.7V to 22 V
Secondary Cells,
and for Batteries 0.02A to 10 A,
Made from Them,
for Use in
External Short Circuit IS 16046 (Part 2)/IEC 62133-2 i) 80±20 mΩ
Portable
(Cell) Clause No: 7.3.1 ii) upto 300
Applications.
Part 2 Lithium iii) upto 999 hrs
System
iv) 0.7V to 22 V
IS 16046 (Part 0.02A to 10 A,
2):2018/IEC 62133-
2:2017 External Short Circuit IS 16046 (Part 2)/IEC 62133-2 i) up to250°C/
(Battery) Clause No: 7.3.2
ii) 80±20 mΩ
iii) upto 300
iv) upto 999 hrs/ lc-1

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 133 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
minute
v) 0.7V-22 V
0.02A to 10 A
Free Fall IS 16046 (Part 2)/IEC 62133-2 i)1Mtr Height
Clause No: 7.3.3 ii) 5 mtr
Qualitative

Thermal Abuse IS 16046 (Part 2)/IEC 62133-2 i) up to250


(Cells) Clause No: 7.3.4 LC 1 ˚C
ii)1800
iii) 0.7V to 22 V
0.02A to 10 A

Crush (Cells) IS 16046 (Part 2)/IEC 62133-2 i) 15kN


Clause No: 7.3.5 ii) 1 mV to 60V DC

iii) 0.7V-22 V

0.02A-10 A,

Over-charging of Battery IS 16046 (Part 2)/IEC 62133-2 i) 0.7V-22 V


Clause No: 7.3.6
0.02A-10 A,
ii) upto 300/
iii) up to 999 hrs

Forced discharge IS 16046 (Part 2)/IEC 62133-2 i) 0.7V-22 V /


(Cells) Clause No: 7.3.7
0.02A-10 A,
ii) upto 999 hrs

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 134 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed

Mechanical tests IS 16046 (Part 2):2018/IEC Qualitative


(batteries) 62133-2:2017
Clause No: 7.3.8
Vibration IS 16046 (Part 2)/IEC 62133-2 i) 1-2000Hz/1 Hz,
Clause No: 7.3.8.1
0.1-25mm.0.01 mm
ii) upto 999 hrs
iii) 0.7V-22 V
0.02A-10 A,

Mechanical chock IS 16046 (Part 2)/IEC 62133-2 i) Average 75G &


Clause No: 7.3.8.2 Peak acc. 125G to
175 G
ii) up to 999 hrs/
iii) 0.7V to 22 V

0.02A to 10 A,

Cell Marking IS 16046 (Part 2)/IEC 62133-2 Qualitative


Clause No: 9.1
IS 16046 (Part 2)/IEC 62133-2 Qualitative
Battery Marking
Clause No: 9.2
IS 16046 (Part 2)/IEC 62133-2 Qualitative
Other Information
Clause No: 9.4
V. BEE ELECTRONICS TESTING

1. Domestic Stand-By Power IEC 62301 AC:0.001 to 600V


Electronic DC: 0.001 to 600V
Appliances & AC 0.001 to 20A
Accessories: (e.g. DC 0.001 to 20A
Television, Desktop 0.001 to 4 kW

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 135 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Computer, Laptop, 0.001 to 100Whr
External Power
Adapter, Battery
Charger, Audio
Equipment,
Combination Units
(TV & DVD, VCR &
DVD), Office
Equipments
(Printers, Scanners,
Copiers, Fax
Machines and Multi
Function Devices)
2. Television Power Consumption IEC 62087 AC/DC :0.001 to
600V
AC/DC 0.001 to 20A
0.001 to 4kW
0.001 to 100Whr

1.0 to 2000 lux


3. AC-DC/DC-DC Energy Efficiency IEC 62301 AC:0.001 to 600V
External Power DC: 0.001 to 600V
Adapter AC 0.001 to 20A
DC 0.001 to 20A
0.001 to 4kW
0.001 to 100Whr
4. Desk Top Power Measurement in IEC 62301 AC:0.001 to 600V
Computers/ Off Mode, Sleep Mode, DC: 0.001 to 600V
Notebook Idle state AC 0.001 to 20A
Computers DC 0.001 to 20A
0.001 to 4 kW
0.001 to 100Whr
5. AC-DC/DC-DC Energy Efficiency IEC 62301 AC:0.001 to 600V
Power Supply DC: 0.001 to 600V

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 136 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
AC 0.001 to 20A
DC 0.001 to 20A
0.001 to 4KW
0.001 to 100Whr
6. Television Luminance IEC 62087 0.01 to 6000 cd/m2

7. Domestic Air delivery IS 374 CMM : 0 to 999,900


Electronic m^3/min,
Appliances & CFM : 0 to 999,900
Accessories: m^3/min.
(e.g. Ceiling Fan
8. Ceiling Fan Fan speed & power IS 374 AC:0.001 to 600V
input DC: 0.001 to 600V
AC 0.001 to 20A
DC 0.001 to 20A
0.001 to 4KW
0.001 to 100Whr
10000 RPM

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 137 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed

MECHANICAL TESTING

I. LEATHER AND LEATHER PRODUCTS

1. Leather- Finished Seat Region IS 15298, Pt-1, 2,3 & Qualitative


leather, leather 4/SASOISO:20344/345/346/34
accessories, 7: / BS EN 15090,
leather products, Construction IS 15298, Pt-1, 2,3 & Qualitative
Semi-finished 4/SASOISO:20344/345/346/34
leather, Synthetic 7: / BS EN 15090,
leather, Others Toe protection (General) IS 15298, Pt-1, 2,3 & Qualitative
4/SASOISO:20344/345/346/34
7: / BS EN 15090,
Specific ergonomic IS 15298, Pt-1, 2,3 & Qualitative
features 4/SASOISO:20344/345/346/34
7: / BS EN 15090,
Upper /Outsole and sole IS 15298, Pt-1, 2,3 & 0.1 to 1000N/mm
inter layer bond 4/SASOISO:20344/345/346/34 / 0.01 N
strength. 7: / BS EN 15090,
Internal Toe Cap Length IS 15298, Pt-1, 2,3 & 30 to 70 mm / 0.1
4/SASOISO:20344/345/346/34 mm
7: / BS EN 15090,
Impact Resistance IS 15298, Pt-1, 2,3 & 0.1 to 25mm / 0.1
4/SASOISO:20344/345/346/34 mm
7: / BS EN 15090,
Compression resistance IS 15298, Pt-1, 2,3 & 0.1 to 25 mm /0.1
4/SASOISO:20344/345/346/34 mm
7: / BS EN 15090,
Corrosion resistance of IS 15298, Pt-1, 2,3 & 0 to 5 mm
metallic toecaps or 4/SASOISO:20344/345/346/34
penetration resistance 7: / BS EN 15090,
metallic inserts

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 138 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed

Dimensional conformity IS 15298, Pt-1, 2,3 & 0.1 to 100 mm / 0.1


4/SASOISO:20344/345/346/34 mm
7: / BS EN 15090,
Penetration resistance IS 15298, Pt-1, 2,3 & 0.1to 20000N / 0.1 N
of inserts 4/SASOISO:20344/345/346/34
7: / BS EN 15090,
Flex resistance of IS 15298, Pt-1, 2,3 & Qualitative
penetration resistant 4/SASOISO:20344/345/346/34
inserts 7: / BS EN 15090,
Electrical resistance IS 15298, Pt-1, 2,3 & 100 KΩ 50000 MΩ,
(Antistatic Test) /ESD 4/SASOISO:20344/345/346/34 100 KΩ
7: / BS EN 15090,
EN 61340-4- 3
Electrical Insulation ISO:20344/345/346/347, , EN 0.1to 25 KV /0.1KV
50321, ASTMF 2412
Insulation against heat IS 15298, Pt-1, 2,3 & 01 to 300 °C / 1 °C
4/SASOISO:20344/345/346/34
7: / BS EN 15090,
Insulation against cold/ IS 15298, Pt-1, 2,3 & 20 to (-30)°C /0.1 °C
Antifreeze test/ Low 4/SASOISO:20344/345/346/34
Temperature Resistance 7: / BS EN 15090,
Energy absorption of the IS 15298, Pt-1,2,3 & 0.2 to 180 J / 1 J
seat region 4/SASOISO:20344/345/346/34
7:/ BS EN 15090,
Water Resistance IS 15298, Pt-1, 2,3 & Qualitative
4/SASOISO:20344/345/346/34
7: / BS EN 15090,
Metatarsal protection IS 15298, Pt-1, 2,3 & 0.1 to 25mm / 0.1
4/SASOISO:20344/345/346/34 mm
7: / BS EN 15090,
Thickness IS 15298, Pt-1, 2,3 & 0.1 to 10 mm / 0.01

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 139 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
4/SASOISO:20344/345/346/34 mm
7: / BS EN 15090,
Height of the upper IS 15298, Pt-1, 2,3 & 0.1 to 300 mm / 0.1
4/SASOISO:20344/345/346/34 mm
7: / BS EN 15090,
Tear Strength IS 15298, Pt-1, 2,3 & 4 0.1 to 20 kN / 0.1 N
SASOIS0:20344/345/346/347/I
S 5914/SATRA TM 162/ BS
EN 15090 / IS 15844/IS 3400
pt 1,
Tensile Strength IS 15298, Pt-1, 2,3 & 4 SASO 0.1 to 20 kN / 0.1 N
IS0:20344/345/346/347/SATR
A TM 43 / BS EN 15090/ IS
15844,
Water Vapour IS 15298, Pt-1, 2,3 & 4/ SASO 0.02 to 300g/0.001g
Permeability IS0:20344/345/346/347/SATR
A TM 23, SATRA TM 47/ BS
EN 15090/ISO 14268, IS 5914,
SATRA TM 172,
Water Vapour IS 15298, Pt-1, 2,3 & 4/SASO 0.02 to 300g / 0.001g
Coefficient ISO:20344/345/346/347/ BS
EN 15090,
Hydrolysis IS 15298, Pt-1, 2,3 & 4/ 01 to 300°C / 100%
SASO RH/1°C & 2% RH
ISO:20344/345/346/347/SATR (Qualitative)
A TM 344/ BS EN 15090,
Abrasion resistance of IS 15298, Pt-1, 2,3 & 4/SASO Qualitative
lining ISO:
20344/345/346/347:2004/SAT
RA TM 31 / BS EN 15090,
Water penetration & IS 15298, Pt-1, 2,3 & 4 / SASO 0.001 to 300g /
water absorption ISO : 20344/345/346/347, IS 0.001g
2925 / BS EN 15090/SATRA

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 140 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
TM 71,
Flexing IS 15844/IS 3400 pt 7 and part Qualitative
8
Thickness of the Insole IS 15298, Pt-1, 2,3 & 4/SASO 0.1 to 50 mm /
ISO:20344/345/346/347/ 0.01mm
SATRA TM -20041 / BS EN
15090,
Water absorption &de- IS 15298, Pt-1, 2,3 & 4/ 0.001 to 300g /
absorption ISO:20344/345/346/347/SATR 0.001g
A TM 6 / BS EN 15090
Abrasion resistance of IS 15298, Pt-1, 2,3 & 4)/ SASO Qualitative
insock ISO:20344/345/346/347/ BS
EN 15090,
Thickness of non IS 15298, Pt-1, 2,3 & 4/SASO 0.1 to 50 mm /0.01
cleated outsole ISO:20344/345/346/347 mm
/SATRA TM 136/ BS EN
15090 / FDDI 08,
Thickness of cleated IS 15298, Pt-1, 2,3 & 4/SASO 0.1 to 50 mm /0.01
outsole (Design) ISO:20344/345/346/347 : mm
/SATRA TM 136/ BS EN
15090/ FDDI 08,
Cleated Area/Height IS 15298, Pt-1, 2,3 & 4/SASO 0.1 - 50 mm /0.01
(Design) ISO:20344/345/346/347 : mm
/SATRA TM 136/ BS EN
15090,
Tear Strength IS 15298, Pt-1, 2,3 & 4/SASO 0.1 to 18 KN/ 0.01N
ISO 20344/345/346/347/
SATRA TM 218 / BS EN
15090/ IS 15844/IS3400 pt
17/ISO 20875,
Abrasion resistance IS 15298, Pt-1, 2,3 & 4 / SASO 0.001 to 300 g /0.001
ISO:20344/345/346/347/ g
SATRA TM 174 / BS EN

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 141 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
15090/IS 3400 pt-3/ IS
15844/ISO 20874

2. Natural rubber , Flexing Resistance IS 15298, Pt-1, 2,3 & 4(2016))/ Flexor 01 to 999999 /
Synthetic rubber, SASO 01 cycle, 0.1 to 10
Rubber ISO:20344/345/346/347/ mm /0.1 mm
compound, SATRA TM 161/ BS EN
Rubber, 15090,
vulcanizates , Resistance to fuel oil IS 15298, Pt-1, 2,3 &4/SASO 0.001 to 300 g /
Rubber Products ISO:20344/345/346/347/ 0.001 g
Thermoplastic SATRA TM 63 / BS EN 15090,
elastomers, Slip Resistance IS 15298, Pt-1, /SASO 0.1 to 1.30
Hard rubber , IS0:20344/345/346/347/ BS
ebonite Rubber EN 15090
Natural , synthetic Ross Flexing After IS 15298, Pt-1, 2,3 &/SASO Flexor 01
Latex Hydrolysis ISO:20344/345/346/347/ -999999/01cycle
Latex goods SATRA TM 60 / BS EN Heating Oven
Textile rubber 15090/IS 3400 pt 16/, 1 to 300 °C / 1 °C
composite Freezing Cabinet +25
Others to (-30)°C/ 1°C
0.1 to 50 mm /0.1mm
Inter Layer Bond IS 15298, Pt-1, 2,3& 4/SASO 0.1 to 10kN / 0.01 N
Strength ISO:20344/345/346/347:2011/
SATRA TM 60 / BS EN 15090/
IS 15844,
Accelerated Ageing IS3400 pt 4 Qualitative
Adhesion of rubber to IS3400 pt 5 Upto 1000 kg/cm
textile fabric
Resistance to liquid IS3400 pt 6 Qualitative
Adhesion to sole IS 15844 0.1 to 100 kg/cm
0.01 kg
Split tear IS 15844 0.1 to 10 kN/ 0.01N

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 142 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Die C tear IS 15844 0.1 to 100 kg/cm
0.1 kg
Adhesion to mid sole IS 15844 0.1 to 100 kg/cm
0.1 kg
3. Hand Gloves Abrasion resistance test EN 388 Visual
Blade cut resistance EN 388 Mass 5 Kg
(Index) Speed - 10 cm/sec
Counter 1 - 106
Accuracy – 1 / 10
cycle, Index 1.2 to
20.0
Tear Resistance EN 388 50 N to 18 000N/
1 to 500mm
Puncture resistance EN 388 50 N to 18 000N/
1 to500 mm
Burning behavior EN: 407 1to 100 sec
Visual observation
Accuracy - 1 second
Contact heat test EN: 407 2 to 500°C ±2°C
Convective heat EN: 407 2 to 300°C ±2°C
Dexterity EN 388/EN 420 Level-4
4. Safety belt Classification IS 3521 Qualitative
Identification of strap IS 3521 Nylon, Polyester
No of stitches per cm IS 3521 Up to 10
Length of lanyard IS 3521 1 meter to 2 meter
Thickness of metal IS 3521 0 to 50 micron
plating
Strength of metal IS 3521 Up to 2500 Kg
(Qualitative)
Attachment means IS 3521 Qualitative
Performance test IS 3521 Qualitative
Width of webbing IS 3521 Cl. 5.1 Up to 50 mm

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 143 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Strength of strap IS 3521 Cl. 5.1 Up to 2500 kg
(Qualitative)
Thickness of webbing IS 3521 Cl. 5.2.1 Up to 10 mm
Flammability of webbing IS 3521 Cl. 5.2.1 Qualitative
and rope
Static load IS 3521 Cl. 5.3.3 Up to 2000 Kg
(Qualitative)
Dynamic load IS 3521Cl. 5.3.4 Qualitative
II. PERFORMANCE/DURABILITY/ SAFETY TEST

1. Protective Shock absorption test IS 2925 Qualitative


helmet for Resistance to penetration IS 2925 0 to 10 mm
Motorcycle test
Riders/ Rigidity test IS 4151 0 to 55 mm
Industrial safety Dynamic test of retention IS 4151 Upto 45mm
helmet system
Audibility test IS 4151 100 dB,
250 to 2000 Hz
Retention test of helmet IS 4151 0 to 500
Opening Angle (Visor) test IS 4151 0 to 500
Flammability IS 2925 Qualitative
Electrical resistance IS 2925 0.1 to 100mA
Water absorption IS 2925 0.1 to 15%
Heat resistance IS 2925 Qualitative
(Temp Range:
(-)20 to 1100C)
2. Furniture Seat Static load test Cl. No. 5.4.1 of EN 12520/Cl Up to 2000 N
Table Seat front aged static load 6.4 of EN 1728 (Qualitative)
Chair test Cl. No. 5.4.1 of EN 12520/Cl
Stool Arm rest downward static 6.5 of EN 1728
load test Cl. No. 5.4.1 of EN 12520/Cl
Footrest static load test 6.11 of EN 1728

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 144 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Additional seat and legs Cl. No. 5.4.1 of EN 12520/Cl
rest static load test 6.8 of EN 1728
Vertical static load test Cl. No. 5.4.1 of EN 12520/Cl
8.3 of EN 1728
Cl. No. 5.4.1 of EN 12521/Cl
6.3 of EN 1730
3. Domestic Gas Strength and rigidity test IS 4246 Cl.15 Qualitative
Stove Used with Ignition and flame travel IS 4246 Cl 18 & IS 5116 Qualitative
LPG Cl 14
Flame stability test IS 4246 Cl 19 Qualitative
Noise control IS 4246 Cl.20 Qualitative
Flash back IS 4246 Cl 21 Qualitative
III. TEXTILE MATERIALS

1. Textiles (Woven & Ends/ Picks density IS;1963 5 to 1000/cm


Non- Woven) IS 14887
Fibre, Filaments, BS2862
Yarn, Cords, Grey ASTMD 3775,
Fabric, Apparels, Breaking Load and IS1969 1N to 15000N
Garments,Made- Elongation -Strip IS 1670 2 to 50%
ups, Carpets, IS 7016 (Pt-2)
Terry fabrics, ASTMD 5035
Domestics textile, Weight per sqmtr/linear IS 1964 10 to 1500 gsm
Industrial textile, meter of fabrics ASTMD 3776
sports textile ISO3801-1977,
Length and width of IS 1954 50 to 500 cm
fabric ASTMD 3773
ASTD 3774
ISO 22198,
Specification of Socks IS 3329
Cotton-
(Constructional Details) 5 to 100 cm
Foot Length, Leg

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 145 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Length, Width of Leg, 10 to100 /cm
Depth of rib 50 to 1500 gm
Wales/Course Qualitative
Weight
Type of knit

Pilling Resistance IS10971 Qualitative


(Box Type) ASTMD 4970 (Grade 1 to 5)
ISO 12945 Pt-1
Abrasion Resistance ASTM D 4966 1 to 99999 cycles
IS 12673
ISO 12947-1
Tear strength IS 7016(Part-3) 1N to 1500N
IS 6489-pt 4
Bursting Strength IS 7016(Part-6), IS 1966 1 to 40 Kg/Cm2
ISO 2960
Drape Coefficient IS 8357 5 to 80%
Crease Recovery Angle IS 4681 / AATCC TM 66 1 to 360o
ISO 2313 / BS 3086
Course / Wales IS 833 A4 & A5 IS 5524 10 to 1000 per dm
Cone Test IS 7941 Qualitative
Spray Test IS 390 / ISO 4920 Qualitative
Blocking Test, Pliability IS 7016(Part-9) Visual
Flammability UIC 5642 app-5 1 to 300mm/min
IS 11871 / IS 12467
ASTMD1230
Grade of wool & Fibre IS 5910 / IS 744 48S to 64 S
dia 0.01 to 1000µm
Dimensional stability to IS 12170 0.1 to100%
dry heat
Yarn breaking strength ISO 2062 ASTMD 204 300 to 2500 g
Loop Test ASTMD 204 300 to 2500 g

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 146 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Knot Test ASTMD 204 300 to 2500 g
Ageing test, Pliability IS 7016 Part 8 Qualitative
(Oven Method)
2. Plastic Zip, Slider, Designation (IS 14181 Pt. 1) Cl. No. 6 Qualitative
Puller, Fastener Slider Locking Type (IS 14181 Pt. 1) Cl. No. 4.1.7.1 Qualitative
Slider Finish (IS 14181 Pt. 1) Cl. No. 7.2 Qualitative
Colour (IS 14181 Pt. 1) Cl. No. 7.4 Qualitative
Length (IS 14181 Pt. 1) Cl. No. 8.2 5 to 100 cm
Textile Chain Width IS 14181 (Pt.1) Cl. No. 8.1 0.5 to 50 mm
Textile Chain Thickness IS 14181 (Pt.1) Cl. No. 8.1 0.1 to 15 mm
Exposed Tape Width IS 14181 (Pt.1) Cl. No. 8.1 0.5 to 30 mm
Puller Length IS 14181 (Pt.1) Cl. No. 8.1 0.5 to 100 mm
Security attachment of IS 14181 (Pt.1) Cl. No. 10.2 0.5N to 250N
top Stop
3. Geo textile Weight per unit area ISO 9864 :, ASTM D5261, 20g/m2 to 6000g/m2
ISO : 9073-1, EDANA 40.3
Tensile Strength ISO 9073-3, 1 N to 15kN
(Strip Method) ASTM D 5035
Trapezoidal tearing ASTM D 4533(Geo), ISO 9073 10N to 5000N
Strength 9073-4 IS 14293
Resistance to exposure ASTM D 4355 1N to 15000N
to light, Moisture & Heat
IV. TOYS AND SIMILAR PRODUCTS

1. Children Products Small Parts EN 71-1:+A2 Qualitative


& Toys (Choking Hazard Test) Clause. 8.2
Tension Test EN 71-1:+A2 Clause. 8.4 Qualitative
2. Expanding Toys Dimensional change in IS 9873-1 ISO 8124-1 0.1-20%
Expanding Material Cl 4.3.2 , Cl.5.21
3. Toys Small Parts Test IS 9873-1 ISO 8124-1 Qualitative
Cl. 4.4, Cl. 5.2
4. Squeeze toys, Template test IS 9873-1 ISO 8124-1 Qualitative

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 147 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Rattles, Cl. 4.5 ,Cl. 5.3
Small
bals,Pompoms, Play
School Play Figures,
Toy Pecifiers,
Balloons, Marbels,
Hemispheric-Shaped
Toys.
5. Small balls and Small ball Test IS 9873-1, ISO 8124-1 Qualitative
Projectiles Cl. 4.5.2 Cl. 5.4
6. Pompoms Test for Pompoms IS 9873-1, ISO 8124-1 Qualitative
Cl. 4.5.3 Cl. 5.5
7. Pre- School Play Pre-school play figures IS 9873-1, ISO 8124-1 Qualitative
Figures Cl. 4.5.4 Cl. 5.6
8. Plastic Films, Plastic film or Plastic IS 9873-1, ISO 8124-1 0.01 to 1.5 mm
Plastic Bags in bags in packaging and Cl.4.10, Cl. 5.10
Packaging of Toys in toys
i)Thickness
9. Toys and Elastic Cords and Elastics in IS 9873-1, ISO 8124-1 0.01 to 220 mm
in Toys toys for children under Cl. 4.11.1, Cl. 5.11.1
18 months
i) Length
ii) Thickness 0.01 to 200 mm
10. Self Retracting Cords and Elastics self IS 9873-1, ISO 8124-1 0.01 to 200 mm
pull Cords in toy retracting pull cords in Cl. No. 4.11.2, Cl. 5.11.2
toys intended for
children under 18
months
i) Length
11. Cords for pull Cords for pull toys IS 9873-1, ISO 8124-1 0.01 to 220 mm
Toys intended under 36 Cl. 4.11.3
months
i) Length

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 148 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
ii) Thickness 0.01 to 200 mm
12. Toy pushchairs, Test for Folding IS 9873-1, ISO 8124-1 Qualitative
perambulators mechanism Cl. 4.12.1, Cl. 5.22.2
and similar toys Toy pushchairs,
perambulators and
similar toys
13. Toys with folding Test for Other toys with IS 9873-1, ISO 8124-1 Qualitative
mechanism folding mechanism Cl. 4.12.2, Cl. 5.22.3

14, Chain or belts in Chain or belts in ride on IS 9873-1, ISO 8124-1 Qualitative
ride on toys toys Cl. 4.13.3, Cl.5.7
15, Ride-on Toys and Sideways stability feet IS 9873-1, ISO 8124-1 Qualitative
Seat available for stabilization Cl. 4.15.1 Cl. 5.12.2
Sideways stability feet IS 9873-1, ISO 8124-1 Qualitative
unavailable for Cl.4.15.1.2, Cl. 5.12.3
stabilization
16, Ride-on toys & Fore and aft stability IS 9873-1, ISO 8124-1 Qualitative
stationary toys Cl. 4.15.1.3, Cl. 5.12.4
17, Ride on toys & Overload requirement for IS 9873-1, ISO 8124-1 Qualitative
seats ride on toys and seats Cl. 4.15.2, Cl. 5.12.5
18, Stationary floor Satiability of stationary IS 9873-1, ISO 8124-1 Qualitative
toys floor toys Cl. 4.15.3, Cl. 5.12.6
19, Lids Doors and Lids Doors and Similar IS 9873-1, ISO 8124-1 Qualitative
Similar devices devices Cl. 4.16.2.1, Cl. 5.13.1

20, Toys containing Toys containing a heat IS 9873-1, ISO 8124-1 Qualitative
heat source source Cl.4.24, Cl. 5.18
21, Liquid filled toys Liquid filled toys IS 9873-1, ISO 8124-1 Qualitative
Cl.4.25, Cl. 5.19
22, Lid support for Closure and toy chest IS 9873-1, ISO 8124-1 Qualitative
toy chest s& lids Cl. 5.13
similar toy
23, Simulated Impact test for toys that IS 9873-1, ISO 8124-1 Qualitative

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 149 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
protective cover the face Cl. 5.14
equipment such
as helmets, hats &
goggles
24, Electrically driven Determination of speed IS 9873-1, ISO 8124-1 0.1 km/h to 15 km/h/
ride-on toys of electrically driven Cl. 5.17 0.1
ride-on toys
25, Toys Washable toys IS 9873-1, ISO 8124-1 Qualitative
Cl. 5.23

Toys Drop test IS 9873-1, ISO 8124-1 Qualitative


Cl. 5.24.2
Torque test IS 9873-1, ISO 8124-1 Qualitative
Cl. 5.24.5
Tension test IS 9873-1, ISO 8124-1 Qualitative
Cl. 5.24.6
Toys Compression test IS 9873-1, ISO 8124-1 Qualitative
Cl. 5.24
26, Mouth actuated Static strength IS 9873-1, ISO 8124-1 Qualitative
toy Cl. 5.26
27, Toy scooter Strength of toy scooter IS 9873-1, ISO 8124-1 Qualitative
steering tubes Cl. 5.29
28, Adjustable & Resistance to IS 9873-1, ISO 8124-1 Qualitative
folding steering separation of handlebar Cl. 5.30
tubes &
handlebars
29, Beards, Flammability – ISO 8124-2 10 to 300 mm/min
moustaches, 1) Burning rate IS 9873-2
wigs, etc. made
form pile or
material that 2) Burning Length Cl. 5.2, Cl. 5.3, Cl. 5.4 1 to 600 mm
behaves in a Cl. 5.5
similar manner to

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 150 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
hair Toy toy worm
on the head,
hood,
headdresses etc.,
Toy distinguish
costumes, soft
filled toys
30, Activity Toy Static strength of activity IS 9873-4, ISO 8124-4 Cl. Qualitative
toys 4.1.1 Cl. 6.2
Maximum Height IS 9873-4, ISO 8124-4 Cl.4.1.2 1 to 5000 mm

31, Barriers & Dynamic strength IS 9873-4, ISO 8124-4 Qualitative


handrails Cl. 6.3
32, Barriers, head & Head and neck IS 9873-4, ISO 8124-4 Cl.6.5 Qualitative
Neck Entrapment entrapment
33, Protrusions All Protrusions IS 9873-4, ISO 8124-4 Qualitative
Cl.6.7
Protrusion in motion IS 9873-4, ISO 8124-4 Cl 6.7.2 Qualitative
rides
34, Inflatable activity Deflation of inflatable IS 9873-4, ISO 8124-4 Qualitative
toys activity toys Cl. No. 6.9
35, Padding pools Static load test for IS 9873-4, ISO 8124-4 Qualitative
with non-inflatable padding pools with non- Cl. No. 6.10
walls inflatable walls
V. PAPER & PAPER PRODUCTS

1. All type of Tensile strength IS 1060 (Part1), IS 1060 (Part 5N to 100 N


Papers II), IS 1848
(Such as Base Burst strength and burst IS 1060 (Part1).IS 1060 (Part 1 kg/cm² to 25
Paper for factor II) kg/cm²
Carbon Paper, Tear strength and tear IS 1060 (Part1): IS 1060 (Part 0.2N to 0.98 N
Writing & factor II), IS 1848
Printing Paper, Thickness IS 5195 0.1 mm to 5 mm

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 151 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Computer Cobb value IS 1848 & Cl. No. 13.2.2 IS 5 to 50 g/m2
Paper, Coated 1060-(Part 1)
Paper & Board, Gloss percent IS 1848 1 to 100%
Cover Paper, Substance/Grammage IS 1060 (Part 1) 0.5 g/m2 to 600 g/m2
Plain Copier Breaking Strength IS 1060 (Part 1) Upto 50 N/mm
Paper, Base Sizing IS 5195 100 to 500 mm
Paper for Denomination IS 5195 10 to 1000 nos
Tracing Paper,
Binding IS 5195 1 to 20 no of stitch
Germination
Paper, Tracing Ruling IS 5195 1 to 50 lines
Paper, Map
Printing Paper)
VI. PLASTICS AND PLASTIC PRODUCTS

1. Plastics & Resins Density Test (Core ASTM D 3574 / ISO:845/ 7 to 300 kg/m3
(Resin, Plastics & Density, IS 7888 / JIS K6400/ ISO:
Polymers, Raw Overall Density, Bulk 2439/ ASTMD 792/ JASO
materials, Plastics Density) M305/IS-7328 /IS-13360 (Part
Films) 3)/IS 7933/IS 3400 pt 9/ISO
2781 IS 10146, IS 10141
Indentation Force ASTM D3574 / 0.1 to 4500 N
Deflection ISO: 2439 / IS 7888/ JIS
Test-Specified Deflection K6400/ DIN 53576/ IS 7933
Sag Factor / Load ASTM D 3574/ 10 to 4500 N
Quotient ISO 2439/ IS 7888/ JIS K6400/
DIN 53576
Compression Force ASTM D 3574 / 1to 50 kPa
Deflection ISO 3386/ IS 7888/ JIS K6400/
(CFD) Test DIN 53574
Constant Deflection ASTM D 3574 / ISO 1856/ 1 to 75%
Compression Set Test IS 7888/ JIS K6400/ ISO 815-2
(Compression set) /ASTM D395 /JASO M305-88 /
IS 7933/ IS 1741/IS 3400 pt

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 152 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
10/ IS 15844/ISO 815
Ultimate Tensile/Tensile ASTM D 3574 / IS 7888/ ISO 1 to 49.03 N/mm2
Strength 1798 /JIS K6400/ M0086/
JASO M305-88
/JASO M305-88 / IS 2530
/ASTMD 638 /IS 8543 (Part 4/
s-1) / IS 7933
Elongation at Break ASTM D 3574 / IS 7888/ ISO 1 to 1000%
1798: /JIS K6400/ M0086/
JASO M305-88
/JASO M305-88 / IS 2530
/ASTMD 638 /IS 8543 (Part 4/
s-1) / IS 7933
Tear Resistance Test ASTM D 3574 /IS 7888:/ 0.002 to 150 N/mm
ISO 8067/ JIS K 6301
ASTM D 624 / ISO 34/ ASTM
D 1004/ JIS K6400/JASO
M305-88P / IS 3400 pt 17 and
pt 12
Resilience (Ball ASTM D 3574 /IS 7888/ISO 5 to 90%
Rebound) Test 8307/ JIS K6400
Static Force Loss Test ASTM D 3574 Thickness Loss: 1 to
at Constant Deflection 75%
IFD range: 10 to
4500 N
Dynamic Fatigue Test ASTM D 3574 / IS 7888/ JIS Thickness Loss: 1to
by Constant Force K6400/ISO 3385 65% / IFD range:10
Pounding to 4500 N
Shear Fatigue ASTM D 3574/ IS 7888 Thickness Loss:1 to
65%/ IFD range:10 to
4500 N
Steam Autoclave Aging ASTM D 3574/ ISO 2440 Thickness Loss: 1 to
75% IFD Range:10

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 153 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
to 4500 N
CFD Range: 1 to 50
kPa
Flammability FMVSS 302/ IS 7888: / UIC Burn Length: 1 to
564- 2: Appendix 8/ ISO 3582/ 256 mm, Time: 01
ISO 3795/UL 94 Seconds
Fire Resistance UIC 564-2: Appendix 4/ UIC Area- 1cm2 to 640cm2
564-2: Appendix 6/ UIC 564-2: Class A, Class B,
Appendix 10/ UIC 564-2: Class C
Appendix 11/ UIC 564-2:
Appendix 12
Hysteresis Loss ASTM D3574/JIS K 6400 1 to 90%

Limited /minimum ASTM D 2863/ IS 13501/IS 10 to 50%


oxygen 13360 pt 6-/ UIC 564-2:
Index Appendix 7
Deterioration of visibility ASTMD 2843/ UIC 564-2: Illumination
due to smoke Appendix 15 Intensity :
1 to 1000 lux
Time: 01 second
Odor SAE J 1351/ISO 12219 (part Rating 1 to 10
-3)/ IS 1741 (Qualitative)
Dry Heat ageing ASTM D 3574 / IS 7888:/ISO: IFD Range 10 to
(calculate% change in 8067/ JIS K6400/IS 7933, IS 4500 N
Physical Properties) 14625 Tensile Test: 0.1to
20 kg/cm2
Tear resistance:0.1to
20 kg/cm2

Elongation at Break:
1 to 250%
Compression Set:

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 154 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
1to 75%
Wet Heat ageing ASTM D 3574 / IS 7888:/ ISO: IFD Range 10 to
(calculate% change in 8067/ JIS K6400 4500 N
Physical Properties) Tensile Test:
0.1 to 20 kg/cm2
Tear resistance:
0.1 to 20 Kg/cm2
Elongation at Break:
01 to 250%
Compression Set:1
to 75%
Humidity exposure ASTMD 2247 38±20 C and 95% to
100%
RH(Qualitative)

Environmental Cyclic JASO M 305-88 , -500 C to 1700 C &


Test JSS: 8110-01 95% to 100% RH
(Qualatitative)
Melt Flow Index(MFI) ASTMD 1238 / IS 2530 0.15 to 100 g/10 min
Co-efficient of friction ASTMD 1894
Compressive Strength ASTM D695 1 to 10000N
Flexural Strength & IS 13360(P5/S-7) -/ASTMD 1 to 10000 N
Modulus 790
Gloss ASTMD 523 1 to100
HDT (Heat Deflection ASTMD 648 40 to 300o C
Temperature)
VSP (Vicat Softening ASTMD 1525 40 to 300o C
point)
Melting Point ASTMD 2117 40 to 350 o C
Toxicity Test NCD 1409 Index 0.1 to 25
Fogging SAEJ1756 0.1 to 150 mg
UV Resistance IS 14887 UV 313 nm
Dimension IS 14887 300 cm

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 155 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
Breaking Load and IS 14887 10 kN load, 1to 500
Elongation -Strip mm Speed
Capacity IS 14887 50 Kg
Salt Spray ISO 9227 Qualitative
Mass IS 14887 0.1 to 200 gm
Vibration Test IS 9000 Part-VIII -2001 RA 5 to 2000Hz, 1 to 175
2015,JIS D 1601,JIS D 5500 g, 25 to 25 mm
displacement
Weathering test SES N 3292, SES 3293, SAE Qualitative
J 1960 SAE J 2527, JASO M
305, IS 2454, ISO 105 B02,
JASO D 001-94
2. Plastic Bottle Dimension of Bottle
a)Height of bottle IS 2798, IS 5168, IS 14625 10 to 300 mm
b)Nech dimension 5 to 60 mm
i)Neck height
ii)Neck dia
c)Wall Thickness 0.01 to 10 mm
Capacity Test IS 14625, IS 5168, IS 2798 100 to 2000ml
Leakage Test IS 2798, IS 14625 Qualitative
Portability Test IS 3025 (Part 5,7 & 8) Qualitative
Drop Test IS 2798, IS 14625 Qualitative

VII. WOOD AND WOOD PRODUCTS

1. Plywood/ Marine Dimensions IS 303 cl no.8/IS 710 cl no


Ply Wood / Timber i)Length 6/IS5509 cl no 8,IS 2380 part Upto 2000 cm
Wood/ Wooden ii)Width 2/IS 4020 Part 2, IS 1659 Cl 7 Upto 1000 cm
Door iii)Height Upto 250 cm
iv)Thickness Upto 40 mm
Moisture content IS 1734 Part 1 0.5 to 30%
IS 1708 Part 1
Density IS 1708 Part 2/ 50 to 1000 kg/m3

Malancha Das Nitan Garg


Convenor Program Manager
Laboratory Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 1: - Atharva Laboratories Pvt. Ltd., B-100, Phase-II, Noida, Uttar Pradesh
Location 2: - Atharva Laboratories Pvt. Ltd., B-140, Phase-II, Noida, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005


Certificate Number TC-6319 (in lieu of T-1554, T-3592, T-3593 & Page 156 of 156
T-1555)
Validity 11.09.2017 to 10.09.2019 Last Amended on 11.01.2019

Sl. Product / Material Specific Test Test Method Specification Range of Testing /
of Test Performed against which tests are Limits of Detection
performed
IS 2380 Part 2
Water absorption IS 2380 Part 16 0.2 to 50%

Malancha Das Nitan Garg


Convenor Program Manager

You might also like