<<Contents>> <<Index>>

General
Specifications Application Portfolios for
FCN/FCJ
GS 34P02P20-01E

■ GENERAL ■ FUNCTION SPECIFICATIONS


This GS describes the application portfolios for FCN/FCJ.
Yokogawa packed its control system expertise in ● Basic Portfolios
cassettes and offers collections of cassettes for individual
PAS Portfolio
processes and applications as Application Portfolios.
From among a range of function blocks used in
(Application Portfolio(s), though written in title cap, is not Yokogawa’s distributed control systems, functions that are
the name of a specific product, but is a bundle of difficult to achieve with IEC61131-3 are chosen and
software parts.) redesigned for IEC61131-3-stipulated languages. PAS
Portfolio provides:
■ FEATURES • Regulatory control blocks, such as indicator, PID
controller, and manual loader blocks, featuring easy-to-
• Packages of software parts carefully chosen and
use instrument faceplates as an operation interface
collected from many years of Yokogawa’s expertise in
• Various calculation blocks featuring frequently used
control system configuration
functions such as a line-segment function, time-delay,
• Sets of documented function specifications, control logic,
temperature and pressure correction
and an application example including operation and
• Using Logic Designer, simply performing wiring between
monitoring window designs
blocks will achieve complex calculations, mode control
• Application portfolios include:
logic, tracking logic, and more.
[Basic Portfolio]
• Sequence control blocks such as preset timers/counters
PAS Portfolio
and switch instrument blocks facilitating development of
SAMA Portfolio
sequence logic and operation and monitoring functions
General-purpose Portfolio
Webmetry Basic Library Portfolio SAMA Portfolio
Time Synchronization Server Portfolio Provides calculation functions compliant with Scientific
[Communication Portfolio] Apparatus Makers Association (SAMA) and often used in
FA-M3 Communication Portfolio power processes.
MELESEC-A Communication Portfolio • Assembling simple calculation functions such as adder,
SYSMAC Communication Portfolio high/low limiter, and PID blocks will build an advanced
Modbus Communication Portfolio control function.
Power Monitor Communication Portfolio • Regardless of using a larger number of function blocks
Temperature Controller Communication Portfolio than when using PAS Portfolio, a loop diagram based on
[Application-specific Portfolio] SAMA Portfolio facilitates much easier identification of a
Boiler Control Portfolio License loop’s functions.
Boiler Auxiliary Control Portfolio License • Use PAS Portfolio together to enable operation and
[Java Package] monitoring of a loop diagram based on SAMA Portfolio.
InfoWell
• Simply copying an application example and modifying it General-purpose Portfolio
to suit the application will build a complex control system Functions developed by drawing on Yokogawa’s years of
effortlessly and with reliability. experience configuring control systems are packed as
cassettes.
• Calculation cassettes, such as cross-limiting and high-
low range switching
• Use of application examples of calculation cassettes and
PAS Portfolio enable configuration of a complex
regulatory control loop.
• Cassettes comprised of calculation and sequence
control routines, such as the resource scheduler and
batch counter
• Use of a complicated sequence application example
such as a process management sequence and material
feed sequence slashes the time needed for engineering
and coding.

Yokogawa Electric Corporation GS 34P02P20-01E


2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan ©Copyright Nov. 2001
Tel.: 81-422-52-5616 URL: http://www.stardom.biz 7th Edition Sep.27, 2004
<<Contents>> <<Index>> 2
Webmetry Basic Library Portfolio ■ OFFERINGS
The Webmetry Basic Library Portfolio is used to facilitate
The following Application Portfolios are offered.
creation of Web-based monitor applications that run on the
FCN/FCJ Java functions. For more details, refer to GS
34P02P50-01E, “Webmetry Basic Library Portfolio.” ● Basic Portfolios

Time Synchronization Server Portfolio PAS Portfolio


FCN/FCJ enables time synchronization among equipment The PAS portfolios provide the following two types of
supporting SNTP (Simple Network Time Protocol). FCN/ POUs with different data properties:
FCJ can operate as an SNTP server or an SNTP client. • NPAS POU: Engineering quantity data is used(*1).
FCN/FCJ requires time synchronization server portfolios in • PAS POU: Normalized data is used(*2).
order to become an SNTP server. When the time synchro-
nization server portfolio license is installed, a time *1: Engineering quantity data means the numerical
synchronization server will start automatically. For details, values based on engineering units. Normally, it is
recommended that NPAS POU be used. NPAS
refer to GS 34P02Q01-01E “FCN/FCJ Autonomous
POU enables intuitive engineering, because
Controller Functions.” engineering quantity data is used.
*2: Normalized data means the numerical values
● Communication Portfolios
normalized from 0 to 100%. Since PAS POU and
Communication portfolios provide STARDOM’s controllers NPAS POU cannot be used at the same time, PAS
with functionality to directly communicate with different POU should be used at the time of using the function
controllers and devices. limited in PAS POU, or expanding system where PAS
• Simple settings in communication devices are all needed POU is used. Following Function are only provided
for bi-directional communication. with PAS POU: PAS_MLD_BT, PAS_FFSUM,
PAS_FFSUM_BL PAS_ASTM1 and PAS_ASTM2.
• For the Modbus Communication Portfolio, refer to GS
34P02P21-01E “Modbus Communication Portfolio.”
Table NPAS POU (1/2)
● Application-specific Portfolios
Application-specific Portfolios are packages of control POU Name Description
functions developed by drawing on Yokogawa's years of NPAS_AI_ANLG Standard analog input
experience configuring control systems and tailored to a
specific process or equipment unit. NPAS_AI_TEMP Measured temperature input

• Combined with functions in PAS and SAMA Portfolios, NPAS_AI_PULS_QT Pulse train input for metering
Application-specific Portfolios help achieve especially integration
hard-to-configure calculation assemblies. NPAS_AI_PULS_CI Pulse train input for control
• Currently offered are portfolios for boiler control and NPAS_AI_PCNT Normalized data input
boiler auxiliary control — more will be released in order.
NPAS_AO_ANLG Standard analog output
● Java Package
NPAS_DI_STS Status input
InfoWell
The InfoWell is designed to allow use of control application NPAS_DO_STS Status output
data by web screen or e-mail without programming. For NPAS_DO_STS_PW Pulse-width output
details, refer to 34P02P51-01E “InfoWell.” NPAS_DO_STS_TP Time-proportioning on/off output
NPAS_FFI_ANLG H1 FOUNDATION Fieldbus (FF-H1)
analog input
NPAS_FFI_STS FF-H1 status input
NPAS_FFO_ANLG FF-H1 analog output
NPAS_FFO_STS FF-H1 status output
NPAS_FFRD_ANLG FF-H1 analog data reading
NPAS_FFRD_STS FF-H1 status data reading
NPAS_FFRD_DINT FF-H1 integer data reading
NPAS_FFWT_ANLG FF-H1 analog data writing
NPAS_FFWT_STS FF-H1 status data writing
NPAS_FFWT_DINT FF-H1 integer data writing
NPAS_PVI Indicator block
NPAS_PID PID controller block
NPAS_PI_HLD Sampling PI controller block
NPAS_ONOFF Two-position on/off controller block
NPAS_ONOFF_G Three-position on/off controller block
NPAS_MLD Manual loader block
(without output tracking)
T26E.EPS

All Rights Reserved. Copyright © 2001, Yokogawa Electric Corporation GS 34P02P20-01E Sep.27,2004-00
<<Contents>> <<Index>> 3
Table NPAS POU (2/2) Table PAS POU (1/2)

POU Name Description POU Name Description


NPAS_MLD_PB Manual loader block PAS_AI_ANLG Standard analog input
(with output pushback)
PAS_AI_TEMP Measured temperature input
NPAS_RATIO Ratio set block (without ratio tracking)
PAS_AI_PULS_QT Pulse train input for metering
NPAS_RATIO_RT Ratio set block (with ratio tracking) integration
NPAS_PG_L30 30-zone program set block PAS_AI_PULS_CI Pulse train input for control
(without bumpless switching)
PAS_AI_PCNT Normalized data input
NPAS_PG_L30_BP 30-zone program set block
(with bumpless switching) PAS_AO_ANLG Standard analog output

NPAS_VELLIM Velocity limiter block PAS_DI_STS Status input


(without output pushback) PAS_DO_STS Status output
NPAS_VELLIM_PB Velocity limiter block PAS_DO_STS_PW Pulse-width output
(with output pushback)
PAS_DO_STS_TP Time-proportioning on/off output
NPAS_AS_H Auto-selector block
(high signal selector) PAS_FFI_ANLG H1 FOUNDATION Fieldbus (FF-H1)
analog input
NPAS_AS_M Auto-selector block
(medium signal selector) PAS_FFI_STS FF-H1 status input
NPAS_AS_L Auto-selector block PAS_FFO_ANLG FF-H1 analog output
(low signal selector)
PAS_FFO_STS FF-H1 status output
NPAS_FOUT Cascade signal distributor block
PAS_FFRD_ANLG FF-H1 analog data reading
NPAS_SW_13 One-pole three-position selector
PAS_FFRD_STS FF-H1 status data reading
(SW_31) switch block
NPAS_SW_19 One-pole nine-position selector PAS_FFRD_DINT FF-H1 integer data reading
(SW_91) switch block PAS_FFWT_ANLG FF-H1 analog data writing
NPAS_BPLS_SW Bumpless switching block PAS_FFWT_STS FF-H1 status data writing
NPAS_SI_1 Switch instrument block with 1 input PAS_FFWT_DINT FF-H1 integer data writing
NPAS_SI_2 Switch instrument block with 2 inputs PAS_PVI Indicator block
NPAS_SO_1 Switch instrument block with 1 output PAS_PID PID controller block
NPAS_SO_2 Switch instrument block with 2 outputs PAS_PI_HLD Sampling PI controller block
NPAS_SIO_11 Switch instrument block with 1 input PAS_ONOFF Two-position on/off controller block
and 1 output
PAS_ONOFF_G Three-position on/off controller block
NPAS_SIO_12 Switch instrument block with 1 input
and 2 outputs PAS_MLD Manual loader block
(without output tracking)
NPAS_SIO_21 Switch instrument block with 2 inputs
and 1 output PAS_MLD_PB Manual loader block
(with output pushback)
NPAS_SIO_22 Switch instrument block with 2 inputs
and 2 outputs PAS_MLD_BT Manual loader block
(with bias tracking)
NPAS_TM Timer with preset value
PAS_RATIO Ratio set block (without ratio tracking)
NPAS_CT Counter with preset value
PAS_RATIO_RT Ratio set block (with ratio tracking)
NPAS_BCD_CI16 16-bit BCD input block
PAS_PG_L30 30-zone program set block
NPAS_BCD_CO16 16-bit BCD output block (without bumpless switching)
NPAS_LDLAG Lead/lag PAS_PG_L30_BP 30-zone program set block
NPAS_DLAY Dead time (with bumpless switching)
NPAS_AVE_M Moving average PAS_VELLIM Velocity limiter block
(without output pushback)
NPAS_AVE_C Cumulative average
PAS_VELLIM_PB Velocity limiter block
NPAS_FUNC_VAR Variable line-segment function (with output pushback)
NPAS_TP_CFL Temperature and pressure correction T01E.EPS

NPAS_T_CFL Temperature correction


NPAS_P_CFL Pressure correction
NPAS_SQRT_LC Square root extraction with low-input
cutoff
NPAS_BDBUF_R Data buffer for real data
NPAS_BDBUF_T Data buffer for time data
T27E.EPS

All Rights Reserved. Copyright © 2001, Yokogawa Electric Corporation GS 34P02P20-01E Sep.27,2004-00
<<Contents>> <<Index>> 4
Table PAS POU (2/2) SAMA Portfolio
POU Name Description POU Name Description
PAS_AS_H Auto-selector block SD _S_MON2 Two-point (HI/LO) monitor switch
(high signal selector)
SD _S_MON4 Four-point (HH/HI/LO/LL) monitor
PAS_AS_M Auto-selector block switch
(medium signal selector)
SD _S_SQRT Square root extractor with low-input
PAS_AS_L Auto-selector block cutoff
(low signal selector)
SD _S_LAG Lag
PAS_FOUT Cascade signal distributor block
SD_S_AVE Moving average
PAS_FFSUM Feedforward signal summing block
(without balancing) SD_S_LDLAG Lead/lag
PAS_FFSUM_BL Feedforward signal summing block SD _S_DLY Dead time
(with balancing) SD _S_LEAD Derivative
PAS_SW_13 (SW_31) One-pole three-position selector SD _S_INTEG Integration
switch block
SD _S_FX Line-segment function
PAS_SW_19 (SW_91) One-pole nine-position selector
switch block SD _S_HSEL High signal selector
PAS_BPLS_SW Bumpless switching block SD _S_MSEL Medium signal selector
PAS_SI_1 Switch instrument block with 1 input SD _S_LSEL Low signal selector
PAS_SI_2 Switch instrument block with 2 inputs SD _S_RLIM Rate limiter
PAS_SO_1 Switch instrument block with 1 output SD _S_HLLIM High/low limiter
PAS_SO_2 Switch instrument block with 2 outputs SD _S_GB Gain and bias calculation
PAS_SIO_11 Switch instrument block with 1 input SD _S_ADD2 Adder
and 1 output
SD _S_DIF2 Subtractor
PAS_SIO_12 Switch instrument block with 1 input
SD _S_MUL2 Multiplier
and 2 outputs
SD _S_DIV2 Divider
PAS_SIO_21 Switch instrument block with 2 inputs
and 1 output SD _S_TSW Signal selector (without output
tracking to target value)
PAS_SIO_22 Switch instrument block with 2 inputs
and 2 outputs SD _S_TSW2 Signal selector (with output tracking
PAS_TM Timer with preset value to target value)
SD _S_PID PID calculation
PAS_CT Counter with preset value
SD _S_MA Manual loader
PAS_BCD_CI16 16-bit BCD input block
SD _S_AND4 Four-input AND
PAS_BCD_CO16 16-bit BCD output block
SD _S_AND8 Eight-input AND
PAS_LDLAG Lead/lag
SD _S_OR4 Four-input OR
PAS_DLAY Dead time
SD _S_OR8 Eight-input OR
PAS_AVE_M Moving average
SD _S_NOT NOT
PAS_AVE_C Cumulative average
SD _S_WOUT Wipeout
PAS_FUNC_VAR Variable line-segment function
SD_S_TDWO Time delay wipeout
PAS_TP_CFL Temperature and pressure correction
SD _S_RTRG Rising-edge trigger
PAS_T_CFL Temperature correction
SD _S_FTRG Falling-edge trigger
PAS_P_CFL Pressure correction
SD _S_FFS Set-dominant flip-flop
PAS_ASTM1 Old JIS-based ASTM correction
SD _S_FFR Reset-dominant flip-flop
PAS_ASTM2 New JIS-based ASTM correction
SD _S_OND On-delay
PAS_SQRT_LC Square root extraction with low-input
cutoff SD _S_OFD Off-delay
PAS_BDBUF_R Data buffer for real data T04E.EPS

PAS_BDBUF_T Data buffer for time data


T02E.EPS

All Rights Reserved. Copyright © 2001, Yokogawa Electric Corporation GS 34P02P20-01E Sep.27,2004-00
<<Contents>> <<Index>> 5
General-purpose Portfolio ● Communication Portfolios
FA-M3 Communication Portfolio
POU Name Description
SD_G_SPLT_FX Split-range calculation with POU Name Description
line-segment function
SD_CFAM3E_OPEN Communication channel opening
SD_G_XLMT_S Single cross-limit (*1) (*4)
SD_G_XLMT_D Double cross-limit SD_CFAM3E_BRD256 Bit device reading (max. 256 points)
(*1)
SD_G_A12SW_A Dual signal selector (type A)
SD_CFAM3E_WRD064 Word device reading (max. 64 points)
SD_G_A12SW_B Dual signal selector (type B) (*1)
SD_G_AI3SW_2OF3 Analog-input 2-out-of-3 circuit SD_CFAM3E_WRD502 Word device reading
SD_G_SLAI2SW_A High-low range switching (type A) (*1) (max. 502 points)
SD_G_SLAI2SW_B High-low range switching (type B) SD_CFAM3E_BWR256 Bit device writing (max. 256 points)
(*1)
SD_G_RS_A8 Eight-input resource scheduler
(permission non-holding) SD_CFAM3E_WWR064 Word device writing (max. 64 points)
(*1)
SD_G_RS_B8 Eight-input resource scheduler
(permission holding) SD_CFAM3E_WWR498 Word device writing (max. 498 points)
(*1)
SD_G_BSET_F Batch set block for flow measurement
SD_CPCLINKM_OPEN Communication channel opening
SD_G_BSET_LW Batch set block for weight (*2, *3)
measurement
SD_CPCLINKM_BRD Bit device reading
SD_G_FEED_SEQ Feed sequence (phase management) (*2, *3)
SD_G_FEED_REQ Feed sequence SD_CPCLINKM_WRD Word device reading
(feed request management) (*2, *3)
SD_G_FEED_REQ_I Feed sequence (feed-request- SD_CPCLINKM_BWR Bit device writing
management input processing) (*2, *3)
SD_G_FEED_REQ_O Feed sequence (feed-request- SD_CPCLINKM_WWR Word device writing
management output processing) (*2, *3)
SD_G_FEED_REQ_T Feed sequence (feed-request- SD_CPCLINKM_WRW Random word device writing
management tracking processing) (*2, *3)
SD_G_PB5 Five-pushbutton block T06E.EPS
*1: Ethernet communication.
SD_G_PB10 Ten-pushbutton block *2: Serial communication.
SD_G_DI3_2OF3 Digital-input 2-out-of-3 circuit *3: These POUs can also be run with the license for
FA-M3 Communication Portfolio, Power Monitor
T05E.EPS
Communication Portfolio, or Temperature Controller
• This portfolio uses normalized data. It should be used Communication Portfolio.
*4: The equipment (not including connections with
with PAS POU when using in combination with a PAS
VDS/ASTMAC and other FCNs/FCJs) to which
portfolio. FCN/FCJ is connected via Ethernet can use a total
of up to 15 channels.

All Rights Reserved. Copyright © 2001, Yokogawa Electric Corporation GS 34P02P20-01E Sep.27,2004-00
<<Contents>> <<Index>> 6
MELSEC-A Communication Portfolio (*1) Power Monitor Communication Portfolio
(All POUs are for Ethernet communication with MELSEC-A
controllers.) POU Name Description
SD_CPM_UPM UPM power monitor POU
POU Name Description (for UPM100)
SD_CMELSECE_ Communication channel opening SD_CPM_UZ_PR UZ/PR power monitor POU
OPEN (*2) (for UZ005/PR201)
SD_CMELSECE_ Bit device reading (max. 256 points) SD_CPM_UPM01 UPM01 power monitor POU
BRD256 (for UPM01/UPM02/UPM03)
SD_CMELSECE_ Word device reading (max. 64 points) SD_CPM_PDEMAND Power demand POU
WRD064
SD_CUPMORGM_ Communication task activation POU
SD_CMELSECE_ Word device reading (max. 256 OPEN for UPM01 only
WRD256 points) T24E.EPS

SD_CMELSECE_ Bit device writing (max. 256 points)


BWR256 • Power monitors that can be connected are shown below.
Note that they require a communication function (RS-
SD_CMELSECE_ Word device writing (max. 64 points) 485).
WWR064 Power monitors manufactured by Yokogawa M&C
SD_CMELSECE_ Word device writing (max. 256 Corporation:
WWR256 points) UPM100, UZ005 (S3 or later), PR201 (S2 or later),
T07E.EPS UPM01, UPM02, UPM03
*1: MELSC-A communication portfolio can communi- • A power monitor can be connected to a serial port (RS-
cate with MELSEC A Serise controllers.Some 232-C) of FCJ, a serial port (RS-232-C) of the FCJ’s
devices (elements) in a MELSEC controller are CPU module, an RS-232-C Communication Module
inaccessible depending on the MELSEC controller
(NFLR111), or an RS-422/RS-485 Communication
model. For communication with MELSEC Q Series
controllers, 1E frame data access is possible. Module (NFLR121). An RS-232-C/RS-485 converter is
*2: The equipment (not including connections with required to connect a power monitor using the RS-232-
VDS/ASTMAC and other FCNs/FCJs) to which C.
FCN/FCJ is connected via Ethernet can use a total • A total of up to eight modules can be installed for each
of up to 15 channels. FCN with respect to RS-232-C Communication Modules
(NFLR111) and RS-422/RS-485 Communication
SYSMAC Communication Portfolio Modules (NFLR121).
All POUs are for serial communication with SYSMAC • If an FCN’s CPU modules are configured in redundancy,
controllers.) it is not possible to use the serial ports (RS-232-C) of
these CPU modules.
POU Name Description • A power monitor and a temperature controller cannot be
used simultaneously on the same communication line.
SD_CSYSMACM_ Communication channel opening • Up to 31 power monitors can be connected on a
OPEN communication line.
SD_CSYSMACM_ Bit device reading • UPM01, UPM02, or UPM03 cannot be used with other
BRD464 power monitors on the same communication line.
SD_CSYSMACM_ Word device reading • The Power Demand POU is a data buffer designed to
WRD029 display power demand graphs. It does not provide data
acquisition and prediction calculation functions.
SD_CSYSMACM_ Bit device writing (Samples of data acquisition and prediction calculation
BWR464
processing are included in the software media.)
SD_CSYSMACM_ Word device writing • This portfolio uses normalized data. It should be used
WWR029 with PAS POU when using in combination with a PAS
SD_CSYSMACM_ Forcible setting/resetting portfolio.
SETRST
SD_CSYSMACM_ Status change
STSCHG
T08E.EPS

All Rights Reserved. Copyright © 2001, Yokogawa Electric Corporation GS 34P02P20-01E Sep.27,2004-00
<<Contents>> <<Index>> 7
Temperature Controller Communication Portfolio ■ STYLE OF SOFTWARE SUPPLY
Software Media
POU Name Description
The programs and documents for all Application Portfolios
SD_CDIC_SCDL UT Schduling excluding PAS Portfolio are supplied as a CD-ROM.
SD_CDIC_UT UT controller Hence, a CD-ROM drive is required for installation in the
computer you use.
SD_CDIC_UT_HC UT HC controller
PAS Portfolio is included in the media (CD-ROM) of FCN/
T10E.EPS
FCJ Software (Model NT203AJ).
• Temperature controllers that can be connected are
shown below. Note that they require a communication Order ID Sheet
function (RS-485). The portfolio licenses come with an order ID sheet with the
Digital Indicating Controllers manufactured by order ID number and password. Access the specified Web
Yokogawa M&C Corporation: site of Yokogawa and enter the order ID number and
SUT350, UT351, UT320, UT450, UT420, UT550, password shown. Then, a file containing the respective
UT520, UT750 license IDs for the supplied portfolios will be given. To use
• A temperature controller can be connected to a serial the Application Portfolio, register the supplied license ID to
port (RS-232-C) of FCJ, a serial port (RS-232-C) of the the FCN/FCJ system card.
FCJ’s CPU module, an RS-232-C Communication
Module (NFLR111), or an RS-422/RS-485 Communica- ■ MODELS AND SUFFIX CODES
tion Module (NFLR121). An RS-232-C/RS-485 converter
is required to connect a temperature controller using the ● Software Media
RS-232-C.
• A total of up to eight modules can be installed for each Description
FCN with respect to RS-232-C Communication Modules Model NT205AJ Application Portfolio software media
(NFLR111) and RS-422/RS-485 Communication
Modules (NFLR121). -P Programs (including electronic documents)
• If an FCN’s CPU modules are configured in redundancy, C CD-ROM
it is not possible to use the serial ports (RS-232-C) of Suffix 1 Always 1
these CPU modules. Codes
• A temperature controller cannot be connected to the 1 Always 1
same RS-485 line with power monitors, and vice versa. E English version
• Up to 16 temperature controllers can be connected per
T13E.EPS
RS-485 line. If a temperature controller performs dual-
loop control, it is counted as two controllers.
● Portfolio Licenses
• This portfolio uses normalized data. It should be used
with PAS POU when using in combination with a PAS
Description
portfolio.
Model NT8001J PAS Portfolio License
● Cassettes in Application-specific Portfolios
-L License
Boiler Control Portfolio
W License ID to be issued via Web
POU Name Description Suffix 1 Always 1
Codes
SD_A_DRMLVL_A Type A pressure compensation for 1 Always 1
drum level (based on SAMA)
A Standard
SD_A_DRMLVL_B Type B pressure compensation for
T14E.EPS
drum level (based on PAS) (*1)
SD_A_STMFL_A Type A steam flow calculation
(based on SAMA) Description
SD_A_STMFL_B Type B steam flow calculation Model NT8002J SAMA Portfolio License
(based on PAS) (*1)
-L License
T11E.EPS
*1: This POU uses normalized data. It should be used W License ID to be issued via Web
with PAS POU, which is a PAS portfolio. Suffix 1 Always 1
Boiler Auxiliary Control Portfolio Codes
1 Always 1
POU Name Description A Standard
SD_A_MOTOR_A Type A motor control (automatic T15E.EPS

failure detection and resetting)


SD_A_MOTOR_B Type B motor control (with external
failure/resetting conditions)
SD_A_VALVE_A Type A valve control (automatic
failure detection and resetting)
SD_A_VALVE_B Type B valve control (with external
failure/resetting conditions)
T12E.EPS

All Rights Reserved. Copyright © 2001, Yokogawa Electric Corporation GS 34P02P20-01E Sep.27,2004-00
<<Contents>> <<Index>> 8
Description Description
Model NT8005J General-purpose Portfolio License Model NT8030E Power Monitor Communication Portfolio
License
-L License
-L License
W License ID to be issued via Web
Suffix W License ID to be issued via Web
1 Always 1
Codes Suffix 1 Always 1
1 Always 1 Codes
1 Always 1
A Standard
T16E.EPS
A Standard
T20E.EPS

Description
NT8040J Time Synchronization Server Portfolio Description
Model
License Model NT8031E Temperature Controller Communication
Portfolio License
-L License
-L License
W The order ID sheet is delivered.
W License ID to be issued via Web
Suffix 1 Always 1
Suffix 1
Codes Always 1
1 Always 1 Codes
1 Always 1
A Standard (common to Japanese and
English versions) A Standard
T25E.EPS T21E.EPS
Note: This license is required only for FCN/FCJ which
implements a server function (SNTP server). It is
not required for clients (SNTP clients). Description
Model NT8101J Boiler Control Portfolio License
Description -L License
Model NT8020J FA-M3 Communication Portfolio License W License ID to be issued via Web
-L License Suffix 1 Always 1
Codes
W License ID to be issued via Web 1 Always 1
Suffix 1 Always 1 A Standard
Codes
1 Always 1 T22E.EPS

A Standard
T17E.EPS Description
Model NT8102J Boiler Auxiliary Control Portfolio License
Description -L License
Model NT8021J MELSEC-A Communication Portfolio W License ID to be issued via Web
License
Suffix 1 Always 1
-L License Codes
1 Always 1
W License ID to be issued via Web
Suffix A Standard
1 Always 1
Codes T23E.EPS
1 Always 1
A Standard
T18E.EPS
■ ORDERING INSTRUCTION
Specify the model and suffix codes.
Description
Model NT8022E SYSMAC Communication Portfolio
■ TRADEMARKS
License • STARDOM is a trademark of Yokogawa Electric
Corporation.
-L License
• MELSEC is a registered trademark of Mitsubishi Electric
W License ID to be issued via Web Corporation.
Suffix 1 • SYSMAC is a registered trademark of OMRON
Always 1
Codes Corporation.
1 Always 1 • Modbus is a registered trademark of AEG Schneider.
A Standard • Other company and product names appearing in this
T19E.EPS document are trademarks or registered trademarks of
their respective holders.

All Rights Reserved. Copyright © 2001, Yokogawa Electric Corporation GS 34P02P20-01E Sep.27,2004-00
Subject to change without notice.