100% found this document useful (2 votes)
4K views

Geankoplis Unit Operation and Transportation

Uploaded by

Vinícius Pianta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
4K views

Geankoplis Unit Operation and Transportation

Uploaded by

Vinícius Pianta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1424

 

                           
                                                 
                                             
                                               
     

Preface
The title of this text has been changed from Transport Processes and Unit Operations to Transport
Processes and Separation Process Principles (Includes Unit Operations). This was done because the
term “unit operations” has been largely superseded by the term “separation processes,” which better
reflects the modern nomenclature being used.

In this fourth edition, the main objectives and the format of the third edition remain the same. The
sections on momentum transfer have been greatly expanded, especially the sections on fluidized beds,
flow meters, mixing, and non-Newtonian fluids. Material has been added to the chapters on mass
transfer. The chapters on absorption, distillation, and liquid–liquid extraction have also been enlarged.
More new material has been added to the sections on ion exchange and crystallization. The chapter on
membrane separation processes has been greatly expanded, especially for gas-membrane theory.

The field of chemical engineering involved with physical and physical–chemical changes of inorganic
and organic materials and, to some extent, biological materials is overlapping more and more with the
other process-engineering fields of ceramic engineering, process metallurgy, agricultural food
engineering, wastewater-treatment (civil) engineering, and bioengineering. The principles of momentum,
heat, and mass transport and the separation processes are widely used in these processing fields.

The principles of momentum transfer and heat transfer have been taught to all engineers. The study of
mass transfer has been limited primarily to chemical engineers. However, engineers in other fields have
become more interested in mass transfer in gases, liquids, and solids.

Since chemical and other engineering students must study so many topics today, a more unified
introduction to the transport processes of momentum, heat, and mass transfer and to the applications of
separation processes is provided. In this text the principles of the transport processes are covered first,
and then the separation processes (unit operations). To accomplish this, the text is divided into two
main parts.

PART 1: Transport Processes: Momentum, Heat, and Mass
This part, dealing with fundamental principles, includes the following chapters: 1. Introduction to
Engineering Principles and Units; 2. Principles of Momentum Transfer and Overall Balances; 3.
Principles of Momentum Transfer and Applications; 4. Principles of Steady-State Heat Transfer; 5.
Principles of Unsteady-State Heat Transfer; 6. Principles of Mass Transfer; and 7. Principles of Unsteady-
State and Convective Mass Transfer.

PART 2: Separation Process Principles (Includes Unit Operations)
This part, dealing with applications, covers the following separation processes: 8. Evaporation; 9.
Drying of Process Materials; 10. Stage and Continuous Gas–Liquid Separation Processes
(humidification, absorption); 11. Vapor–Liquid Separation Processes (distillation); 12. Liquid–Liquid
and Fluid–Solid Separation Processes (adsorption, ion exchange, extraction, leaching, crystallization);
13. Membrane Separation Processes (dialysis, gas separation, reverse osmosis, ultrafiltration,
microfiltration); 14. Mechanical–Physical Separation Processes (filtration, settling, centrifugal
separation, mechanical size reduction).

In Chapter 1 elementary principles of mathematical and graphical methods, laws of chemistry and
physics, material balances, and heat balances are reviewed. Many readers, especially chemical engineers,
may be familiar with most of these principles and may omit all or parts of this chapter.

A few topics, primarily those concerned with the processing of biological materials, may be omitted at the
discretion of the reader or instructor; these include Sections 5.5, 6.4, 8.7, 9.11, and 9.12. Over 240
example or sample problems and over 550 homework problems on all topics are included in the text.
Some of the homework problems involve biological systems, for those readers who are especially
interested in that area.

This text may be used for a course of study following any of the following five suggested plans. In all
plans, Chapter 1 may or may not be included.

1.  Study of transport processes of momentum, heat, and mass and separation processes. In this
plan, most of the entire text, covering the principles of the transport processes in Part 1 and the
separation processes in Part 2, is covered. This plan would be applicable primarily to chemical
engineering as well as to other process-engineering fields in a one-and-one-half-year course of
study at the junior and/or senior level.

2.  Study of transport processes of momentum, heat, and mass and selected separation processes.
Only the elementary sections of Part 1 (the principles chapters-2, 3, 4, 5, 6, and 7) are covered,
plus selected separation-processes topics in Part 2 applicable to a particular field, in a two-
semester or three-quarter course. Students in environmental engineering, food process
engineering, and process metallurgy could follow this plan.

3.  Study of transport processes of momentum, heat, and mass. The purpose of this plan in a two-
quarter or two-semester course is to obtain a basic understanding of the transport processes of
momentum, heat, and mass transfer. This involves studying sections of the principles chapters-2,
3, 4, 5, 6, and 7 in Part 1—and omitting Part 2, the applied chapters on separation processes.

4.  Study of separations processes. If the reader has had courses in the transport processes of
momentum, heat, and mass, Chapters 2–7 can be omitted and only the separation processes
chapters in Part 2 studied in a one-semester or two-quarter course. This plan could be used by
chemical and certain other engineers.

5.  Study of mass transfer. For those such as chemical or mechanical engineers who have had
momentum and heat transfer, or those who desire only a background in mass transfer in a one-
quarter or one-semester course, Chapters 6, 7, and 10 would be covered. Chapters 9, 11, 12, and 13
might be covered optionally, depending on the needs of the reader.

Different schools and instructors differ on the use of computers in engineering courses. All of the
equations and homework problems in this text can be solved by using ordinary hand-held computers.
However, more complicated problems involving numerical integration, finite-difference calculations,
steady- and unsteady-state two-dimensional diffusion and conduction, and so on, can easily be solved
with a computer using spreadsheets. Almost all undergraduate students are proficient in their use.

The SI (Système International d'Unités) system of units has been adopted by the scientific community.
Because of this, the SI system of units has been adopted in this text for use in the equations, example
problems, and homework problems. However, the most important equations derived in the text are also
given in a dual set of units, SI and English, when different. Many example and homework problems are
also given using English units.

Christie John Geankoplis
Chap ter 3. P rincip les  o f  Mo m entum  Trans f er and  A p p licatio ns

Sect on 3.1. FLOW PAST IMMERSED OBJECTS AND PACKED AND FLUIDIZED BEDS

Sect on 3.2. MEASUREMENT OF FLOW OF FLUIDS

Sect on 3.3. PUMPS AND GAS-MOVING EQUIPMENT

Sect on 3.4. AGITATION AND MIXING OF FLUIDS AND POWER REQUIREMENTS

Sect on 3.5. NON-NEWTONIAN FLUIDS

Sect on 3.6. DIFFERENTIAL EQUATIONS OF CONTINUITY

Sect on 3.7. DIFFERENTIAL EQUATIONS OF MOMENTUM TRANSFER OR MOTION

Sect on 3.8. USE OF DIFFERENTIAL EQUATIONS OF CONTINUITY AND MOTION

Sect on 3.9. OTHER METHODS FOR SOLUTION OF DIFFERENTIAL EQUATIONS OF MOTION

Sect on 3.10. BOUNDARY-LAYER FLOW AND TURBULENCE

Sect on 3.11. DIMENSIONAL ANALYSIS IN MOMENTUM TRANSFER

PROBLEMS

REFERENCES

Chap ter 4. P rincip les  o f  Stead y-State Heat Trans f er

Sect on 4.1. INTRODUCTION AND MECHANISMS OF HEAT TRANSFER

Sect on 4.2. CONDUCTION HEAT TRANSFER

Sect on 4.3. CONDUCTION THROUGH SOLIDS IN SERIES

Sect on 4.4. STEADY-STATE CONDUCTION AND SHAPE FACTORS

Sect on 4.5. FORCED CONVECTION HEAT TRANSFER INSIDE PIPES

Sect on 4.6. HEAT TRANSFER OUTSIDE VARIOUS GEOMETRIES IN FORCED CONVECTION

Sect on 4.7. NATURAL CONVECTION HEAT TRANSFER

Sect on 4.8. BOILING AND CONDENSATION

Sect on 4.9. HEAT EXCHANGERS

Sect on 4.10. INTRODUCTION TO RADIATION HEAT TRANSFER

Sect on 4.11. ADVANCED RADIATION HEAT-TRANSFER PRINCIPLES

Sect on 4.12. HEAT TRANSFER OF NON-NEWTONIAN FLUIDS

Sect on 4.13. SPECIAL HEAT-TRANSFER COEFFICIENTS

Sect on 4.14. DIMENSIONAL ANALYSIS IN HEAT TRANSFER

Sect on 4.15. NUMERICAL METHODS FOR STEADY-STATE CONDUCTION IN TWO DIMENSIONS

PROBLEMS

REFERENCES

Chap ter 5. P rincip les  o f  Uns tead y-State Heat Trans f er

Sect on 5.1. DERIVATION OF BASIC EQUATION

Sect on 5.2. SIMPLIFIED CASE FOR SYSTEMS WITH NEGLIGIBLE INTERNAL RESISTANCE

Sect on 5.3. UNSTEADY-STATE HEAT CONDUCTION IN VARIOUS GEOMETRIES

Sect on 5.4. NUMERICAL FINITE-DIFFERENCE METHODS FOR UNSTEADY-STATE CONDUCTION

Sect on 5.5. CHILLING AND FREEZING OF FOOD AND BIOLOGICAL MATERIALS

Sect on 5.6. DIFFERENTIAL EQUATION OF ENERGY CHANGE

Sect on 5.7. BOUNDARY-LAYER FLOW AND TURBULENCE IN HEAT TRANSFER

PROBLEMS

REFERENCES

Chap ter 6. P rincip les  o f  Mas s  Trans f er

Sect on 6.1. INTRODUCTION TO MASS TRANSFER AND DIFFUSION

Sect on 6.2. MOLECULAR DIFFUSION IN GASES

Sect on 6.3. MOLECULAR DIFFUSION IN LIQUIDS

Sect on 6.4. MOLECULAR DIFFUSION IN BIOLOGICAL SOLUTIONS AND GELS
Sect on 6.5. MOLECULAR DIFFUSION IN SOLIDS

Sect on 6.6. NUMERICAL METHODS FOR STEADY-STATE MOLECULAR DIFFUSION IN TWO DIMENSIONS

PROBLEMS

REFERENCES

Chap ter 7. P rincip les  o f  Uns tead y-State and  Co nvective Mas s  Trans f er

Sect on 7.1. UNSTEADY-STATE DIFFUSION

Sect on 7.2. CONVECTIVE MASS-TRANSFER COEFFICIENTS

Sect on 7.3. MASS-TRANSFER COEFFICIENTS FOR VARIOUS GEOMETRIES

Sect on 7.4. MASS TRANSFER TO SUSPENSIONS OF SMALL PARTICLES

Sect on 7.5. MOLECULAR DIFFUSION PLUS CONVECTION AND CHEMICAL REACTION

Sect on 7.6. DIFFUSION OF GASES IN POROUS SOLIDS AND CAPILLARIES

Sect on 7.7. NUMERICAL METHODS FOR UNSTEADY-STATE MOLECULAR DIFFUSION

Sect on 7.8. DIMENSIONAL ANALYSIS IN MASS TRANSFER

Sect on 7.9. BOUNDARY-LAYER FLOW AND TURBULENCE IN MASS TRANSFER

PROBLEMS

REFERENCES

P art: 2 Sep aratio n P ro ces s  P rincip les  (I nclud es  Unit Op eratio ns )

Chap ter 8. Evap o ratio n

Sect on 8.1. INTRODUCTION

Sect on 8.2. TYPES OF EVAPORATION EQUIPMENT AND OPERATION METHODS

Sect on 8.3. OVERALL HEAT-TRANSFER COEFFICIENTS IN EVAPORATORS

Sect on 8.4. CALCULATION METHODS FOR SINGLE-EFFECT EVAPORATORS

Sect on 8.5. CALCULATION METHODS FOR MULTIPLE-EFFECT EVAPORATORS

Sect on 8.6. CONDENSERS FOR EVAPORATORS

Sect on 8.7. EVAPORATION OF BIOLOGICAL MATERIALS

Sect on 8.8. EVAPORATION USING VAPOR RECOMPRESSION

PROBLEMS

REFERENCES

Chap ter 9. Drying  o f  P ro ces s  Materials

Sect on 9.1. INTRODUCTION AND METHODS OF DRYING

Sect on 9.2. EQUIPMENT FOR DRYING

Sect on 9.3. VAPOR PRESSURE OF WATER AND HUMIDITY

Sect on 9.4. EQUILIBRIUM MOISTURE CONTENT OF MATERIALS

Sect on 9.5. RATE-OF-DRYING CURVES

Sect on 9.6. CALCULATION METHODS FOR CONSTANT-RATE DRYING PERIOD

Sect on 9.7. CALCULATION METHODS FOR FALLING-RATE DRYING PERIOD

Sect on 9.8. COMBINED CONVECTION, RADIATION, AND CONDUCTION HEAT TRANSFER IN CONSTANT-RATE PERIOD

Sect on 9.9. DRYING IN FALLING-RATE PERIOD BY DIFFUSION AND CAPILLARY FLOW

Sect on 9.10. EQUATIONS FOR VARIOUS TYPES OF DRYERS

Sect on 9.11. FREEZE-DRYING OF BIOLOGICAL MATERIALS

Sect on 9.12. UNSTEADY-STATE THERMAL PROCESSING AND STERILIZATION OF BIOLOGICAL MATERIALS

PROBLEMS

REFERENCES

Chap ter 10. Stag e and  Co ntinuo us  Gas –Liq uid  Sep aratio n P ro ces s es

Sect on 10.1. TYPES OF SEPARATION PROCESSES AND METHODS

Sect on 10.2. EQUILIBRIUM RELATIONS BETWEEN PHASES

Sect on 10.3. SINGLE AND MULTIPLE EQUILIBRIUM CONTACT STAGES
Sect on 10.4. MASS TRANSFER BETWEEN PHASES

Sect on 10.5. CONTINUOUS HUMIDIFICATION PROCESSES

Sect on 10.6. ABSORPTION IN PLATE AND PACKED TOWERS

Sect on 10.7. ABSORPTION OF CONCENTRATED MIXTURES IN PACKED TOWERS

Sect on 10.8. ESTIMATION OF MASS-TRANSFER COEFFICIENTS FOR PACKED TOWERS

Sect on 10.9. HEAT EFFECTS AND TEMPERATURE VARIATIONS IN ABSORPTION

PROBLEMS

REFERENCES

Chap ter 11. Vap o r–Liq uid  Sep aratio n P ro ces s es

Sect on 11.1. VAPOR–LIQUID EQUILIBRIUM RELATIONS

Sect on 11.2. SINGLE-STAGE EQUILIBRIUM CONTACT FOR VAPOR–LIQUID SYSTEM

Sect on 11.3. SIMPLE DISTILLATION METHODS

Sect on 11.4. DISTILLATION WITH REFLUX AND McCABE–THIELE METHOD

Sect on 11.5. DISTILLATION AND ABSORPTION EFFICIENCIES FOR TRAY AND PACKED TOWERS

Sect on 11.6. FRACTIONAL DISTILLATION USING ENTHALPY–CONCENTRATION METHOD

Sect on 11.7. DISTILLATION OF MULTICOMPONENT MIXTURES

PROBLEMS

REFERENCES

Chap ter 12. Liq uid –Liq uid  and  Fluid –So lid  Sep aratio n P ro ces s es

Sect on 12.1. INTRODUCTION TO ADSORPTION PROCESSES

Sect on 12.2. BATCH ADSORPTION

Sect on 12.3. DESIGN OF FIXED-BED ADSORPTION COLUMNS

Sect on 12.4. ION-EXCHANGE PROCESSES

Sect on 12.5. SINGLE-STAGE LIQUID–LIQUID EXTRACTION PROCESSES

Sect on 12.6. TYPES OF EQUIPMENT AND DESIGN FOR LIQUID–LIQUID EXTRACTION

Sect on 12.7. CONTINUOUS MULTISTAGE COUNTERCURRENT EXTRACTION

Sect on 12.8. INTRODUCTION AND EQUIPMENT FOR LIQUID–SOLID LEACHING

Sect on 12.9. EQUILIBRIUM RELATIONS AND SINGLE-STAGE LEACHING

Sect on 12.10. COUNTERCURRENT MULTISTAGE LEACHING

Sect on 12.11. INTRODUCTION AND EQUIPMENT FOR CRYSTALLIZATION

Sect on 12.12. CRYSTALLIZATION THEORY

PROBLEMS

REFERENCES

Chap ter 13. Mem b rane Sep aratio n P ro ces s es

Sect on 13.1. INTRODUCTION AND TYPES OF MEMBRANE SEPARATION PROCESSES

Sect on 13.2. LIQUID PERMEATION MEMBRANE PROCESSES OR DIALYSIS

Sect on 13.3. GAS PERMEATION MEMBRANE PROCESSES

Sect on 13.4. COMPLETE-MIXING MODEL FOR GAS SEPARATION BY MEMBRANES

Sect on 13.5. COMPLETE-MIXING MODEL FOR MULTICOMPONENT MIXTURES

Sect on 13.6. CROSS-FLOW MODEL FOR GAS SEPARATION BY MEMBRANES

Sect on 13.7. DERIVATION OF EQUATIONS FOR COUNTERCURRENT AND COCURRENT FLOW FOR GAS SEPARATION FOR MEMBRANES

Sect on 13.8. DERIVATION OF FINITE-DIFFERENCE NUMERICAL METHOD FOR ASYMMETRIC MEMBRANES

Sect on 13.9. REVERSE-OSMOSIS MEMBRANE PROCESSES

Sect on 13.10. APPLICATIONS, EQUIPMENT, AND MODELS FOR REVERSE OSMOSIS

Sect on 13.11. ULTRAFILTRATION MEMBRANE PROCESSES

Sect on 13.12. MICROFILTRATION MEMBRANE PROCESSES

PROBLEMS

REFERENCES
Chap ter 14. Mechanical–P hys ical Sep aratio n P ro ces s es

Sect on 14.1. INTRODUCTION AND CLASSIFICATION OF MECHANICAL–PHYSICAL SEPARATION PROCESSES

Sect on 14.2. FILTRATION IN SOLID–LIQUID SEPARATION

Sect on 14.3. SETTLING AND SEDIMENTATION IN PARTICLE–FLUID SEPARATION

Sect on 14.4. CENTRIFUGAL SEPARATION PROCESSES

Sect on 14.5. MECHANICAL SIZE REDUCTION

PROBLEMS

REFERENCES

A p p end ix A .1: Fund am ental Co ns tants  and  Co nvers io n Facto rs

Sect on A.1-1. Gas Law Constant R

Sect on A.1-2. Volume and Density

Sect on A.1-3. Length

Sect on A.1-4. Mass

Sect on A.1-5. Standard Acceleration of Grav ty

Sect on A.1-6. Volume

Sect on A.1-7. Force

Sect on A.1-8. Pressure

Sect on A.1-9. Power

Sect on A.1-10. Heat, Energy, Work

Sect on A.1-11. Thermal Conductiv ty

Sect on A.1-12. Heat-Transfer Coefficient

Sect on A.1-13. Viscos ty

Sect on A.1-14. Diffusiv ty

Sect on A.1-15. Mass Flux and Molar Flux

Sect on A.1-16. Heat Flux and Heat Flow

Sect on A.1-17. Heat Capacity and Enthalpy

Sect on A.1-18. Mass-Transfer Coefficient

Sect on A.1-19. Temperature

Appendix A.2: Physical Properties of Water

Appendix A.3: Physical Properties of Inorganic and Organ c Compounds

A p p end ix A .4: P hys ical P ro p erties  o f  Fo o d s  and  Bio lo g ical Materials

Sect on A.4-2. Thermal Conductiv ties, Dens ties, and Viscosities of Foods

Appendix A.5: Properties of Pipes, Tubes, and Screens

Notat on

About the Author

Index
                             
                                                 
                                             
                                               
     

Part 1: Transport Processes: Momentum, Heat, and Mass
Introduction to Engineering Principles and Units

Principles of Momentum Transfer and Overall Balances

Principles of Momentum Transfer and Applications

Principles of Steady-State Heat Transfer

Principles of Unsteady-State Heat Transfer

Principles of Mass Transfer

Principles of Unsteady-State and Convective Mass Transfer
                             
                                                 
                                             
                                               
     

Chapter 1. Introduction to Engineering Principles and
Units
CLASSIFICATION OF TRANSPORT PROCESSES AND SEPARATION PROCESSES (UNIT
OPERATIONS)

SI SYSTEM OF BASIC UNITS USED IN THIS TEXT AND OTHER SYSTEMS

METHODS OF EXPRESSING TEMPERATURES AND COMPOSITIONS

GAS LAWS AND VAPOR PRESSURE

CONSERVATION OF MASS AND MATERIAL BALANCES

ENERGY AND HEAT UNITS

CONSERVATION OF ENERGY AND HEAT BALANCES

NUMERICAL METHODS FOR INTEGRATION

PROBLEMS

REFERENCES
                             
                                                 
                                             
                                               
     

1.1. CLASSIFICATION OF TRANSPORT PROCESSES AND
SEPARATION PROCESSES (UNIT OPERATIONS)

1.1A. Intr od u ction

In the chemical and other physical processing industries and the food and biological processing
industries, many similarities exist in the manner in which the entering feed materials are modified or
processed into final materials of chemical and biological products. We can take these seemingly different
chemical, physical, or biological processes and break them down into a series of separate and distinct
steps that were originally called unit operations. However, the term “unit operations” has largely been
superseded by the more modern and descriptive term “separation processes.” These separation processes
are common to all types of diverse process industries.

For example, the separation process distillation is used to purify or separate alcohol in the beverage
industry and hydrocarbons in the petroleum industry. Drying of grain and other foods is similar to
drying of lumber, filtered precipitates, and wool. The separation process absorption occurs in absorption
of oxygen from air in a fermentation process or in a sewage treatment plant and in absorption of
hydrogen gas in a process for liquid hydrogenation of oil. Evaporation of salt solutions in the chemical
industry is similar to evaporation of sugar solutions in the food industry. Settling and sedimentation of
suspended solids in the sewage industry and the mining industry are similar. Flow of liquid
hydrocarbons in the petroleum refinery and flow of milk in a dairy plant are carried out in a similar
fashion.

Many of these separation processes have certain fundamental and basic principles or mechanisms in
common. For example, the mechanism of diffusion or mass transfer occurs in drying, membrane
separation, absorption, distillation, and crystallization. Heat transfer occurs in drying, distillation,
evaporation, and so on. The following classification of a more fundamental nature is often made,
according to transfer or transport processes.

1.1B. Fu nd am e ntal Tr ansp or t Pr oce sse s

1. M oment u m t r a nsfer

This is concerned with the transfer of momentum which occurs in moving media, such as in the
separation processes of fluid flow, sedimentation, mixing, and filtration.

2. Hea t  t r a nsfer

In this fundamental process, we are concerned with the transfer of heat from one place to another; it
occurs in the separation processes of drying, evaporation, distillation, and others.

3. M a ss t r a nsfer

Here mass is being transferred from one phase to another distinct phase; the basic mechanism is the
same whether the phases are gas, solid, or liquid. This includes distillation, absorption, liquid–liquid
extraction, membrane separation, adsorption, crystallization, and leaching.

1.1C . C lassification of S e p ar ation Pr oce sse s

The separation processes deal mainly with the transfer and change of energy and the transfer and change
of materials, primarily by physical means but also by physical–chemical means. The important
separation processes, which can be combined in various sequences in a process and which are covered in
this text, are described next.

1. Ev a p or a t ion

This refers to the evaporation of a volatile solvent such as water from a nonvolatile solute such as salt or
any other material in solution.

2. Dr y ing

In this operation volatile liquids, usually water, are removed from solid materials.

3. Dist illa t ion

This is an operation whereby components of a liquid mixture are separated by boiling because of their
differences in vapor pressure.

4 . Ab sor p t ion

In this process a component is removed from a gas stream by treatment with a liquid.

5. M emb r a ne sep a r a t ion

This process involves the separation of a solute from a fluid by diffusion of this solute from a liquid or gas
through a semipermeable membrane barrier to another fluid.

6 . Liq u id –liq u id  ext r a ct ion

In this case a solute in a liquid solution is removed by contacting with another liquid solvent that is
relatively immiscible with the solution.

7. Ad sor p t ion

In this process a component of a gas or liquid stream is removed and adsorbed by a solid adsorbent.

8. Ion excha ng e

Certain ions in solution are removed from a liquid by an ion-exchange solid.

9 . Liq u id –solid  lea ching

This involves treating a finely divided solid with a liquid that dissolves out and removes a solute
contained in the solid.

10. C r y st a lliza t ion

This concerns the removal of a solute such as a salt from a solution by precipitating the solute from the
solution.
11. M echa nica l–p hy sica l sep a r a t ions

These involve separation of solids, liquids, or gases by mechanical means, such as filtration, settling,
centrifugation, and size reduction.

1.1D. Ar r ange m e nt in Par ts 1 and  2

This text is arranged in two parts:

Pa r t  1: Tr a nsp or t  Pr ocesses: M oment u m, Hea t , a nd  M a ss

These fundamental principles are covered extensively in Chapters 1 through 7 in order to provide the
basis for study of separation processes in Part 2 of this text.

Pa r t  2: S ep a r a t ion Pr ocess Pr incip les (Inclu d es Unit  Op er a t ions)

The various separation processes and their applications to process areas are studied in Part 2 of this text.

There are a number of elementary engineering principles, mathematical techniques, and laws of physics
and chemistry that are basic to a study of the principles of momentum, heat, and mass transfer and the
separation processes. These are reviewed for the reader in this first chapter. Some readers, especially
chemical engineers, agricultural engineers, civil engineers, and chemists, may be familiar with many of
these principles and techniques and may wish to omit all or parts of this chapter.

Homework problems at the end of each chapter are arranged in different sections, each corresponding to
the number of a given section in the chapter.
                             
                                                 
                                             
                                               
     

1.2. SI SYSTEM OF BASIC UNITS USED IN THIS TEXT AND OTHER
SYSTEMS
There are three main systems of basic units employed at present in engineering and science. The first and
most important of these is the SI (Système International d'Unités) system, which has as its three basic
units the meter (m), the kilogram (kg), and the second (s). The others are the English foot (ft)–pound
(lb)–second (s), or English system and the centimeter (cm)–gram (g)–second (s), or cgs system.

At present the SI system has been adopted officially for use exclusively in engineering and science, but
the older English and cgs systems will still be used for some time. Much of the physical and chemical
data and empirical equations are given in these latter two systems. Hence, the engineer not only should
be proficient in the SI system but must also be able to use the other two systems to a limited extent.

1.2A. S I S yste m  of Units

The basic quantities used in the SI system are as follows: the unit of length is the meter (m); the unit of
time is the second (s); the unit of mass is the kilogram (kg); the unit of temperature is the kelvin (K); and
the unit of an element is the kilogram mole (kg mol). The other standard units are derived from these
basic quantities.

The basic unit of force is the newton (N), defined as

The basic unit of work, energy, or heat is the newton-meter, or joule (J).

Power is measured in joules/s or watts (W).

The unit of pressure is the newton/m2 or pascal (Pa).

[Pressure in atmospheres (atm) is not a standard SI unit but is being used during the transition period.]
The standard acceleration of gravity is defined as
A few of the standard prefixes for multiples of the basic units are as follows: giga (G) = 109, mega (M) =
106, kilo (k) = 103, centi (c) = 10−2, milli (m) = 10−3, micro (µ) = 10−6, and nano (n) = 10−9. The prefix c
is not a preferred prefix.

Temperatures are defined in kelvin (K) as the preferred unit in the SI system. However, in practice, wide
use is made of the degree Celsius (°C) scale, which is defined by

Note that 1°C = 1 K and that in the case of temperature difference,

The standard preferred unit of time is the second (s), but time can be in nondecimal units of minutes
(min), hours (h), or days (d).

1.2B. C G S  S yste m  of Units

The cgs system is related to the SI system as follows:

The standard acceleration of gravity is

1.2C . English fp s S yste m  of Units

The English system is related to the SI system as follows:
The proportionality factor for Newton's law is

The factor g c in SI units and cgs units is 1.0 and is omitted.

In Appendix A.1, convenient conversion factors for all three systems are tabulated. Further discussions
and use of these relationships are given in various sections of the text.

This text uses the SI system as the primary set of units in the equations, sample problems, and
homework problems. However, the important equations derived in the text are given in a dual set of
units, SI and English, when these equations differ. Some example problems and homework problems are
also given using English units. In some cases, intermediate steps and/or answers in example problems
are also stated in English units.

1.2D. Dim e nsionally Hom oge ne ou s Eq u ations and  C onsiste nt Units

A dimensionally homogeneous equation is one in which all the terms have the same units. These units
can be the base units or derived ones (for example, kg/s2 · m or Pa). Such an equation can be used with
any system of units provided that the same base or derived units are used throughout the equation. No
conversion factors are needed when consistent units are used.

The reader should be careful in using any equation and always check it for dimensional homogeneity. To
do this, a system of units (SI, English, etc.) is first selected. Then units are substituted for each term in
the equation and like units in each term canceled out.
                             
                                                 
                                             
                                               
     

1.3. METHODS OF EXPRESSING TEMPERATURES AND
COMPOSITIONS

1.3A. Te m p e r atu r e

There are two temperature scales in common use in the chemical and biological industries. These are
degrees Fahrenheit (abbreviated °F) and Celsius (°C). It is often necessary to convert from one scale to
the other. Both use the freezing point and boiling point of water at 1 atmosphere pressure as base points.
Often temperatures are expressed as absolute degrees K (SI standard) or degrees Rankine (°R) instead of
°C or °F. Table 1.3-1 shows the equivalences of the four temperature scales.

Table 1.3-1. Temperature Scales and Equivalents

  Centigrade Fahrenheit Kelvin Rankine Celsius

Boiling water 100°C 212°F 373.15 K 671.67°R 100°C

Melting ice 0°C 32°F 273.15 K 491.67°R 0°C

Absolute zero −273.15°C −459.67°F 0 K 0°R −273.15°C

The difference between the boiling point of water and melting point of ice at 1 atm is 100°C or 180°F.
Thus, a 1.8°F change is equal to a 1°C change. Usually, the value of −273.15°C is rounded to −273.2°C
and −459.67°F to −460°F. The following equations can be used to convert from one scale to another:

Equation 1.3-1

Equation 1.3-2

Equation 1.3-3

Equation 1.3-4
1.3B. M ole  Units, and  W e ight or  M ass Units

There are many methods used to express compositions in gases, liquids, and solids. One of the most
useful is molar units, since chemical reactions and gas laws are simpler to express in terms of molar
units. A mole (mol) of a pure substance is defined as the amount of that substance whose mass is
numerically equal to its molecular weight. Hence, 1 kg mol of methane CH4 contains 16.04 kg. Also, 1.0
lb mol contains 16.04 lbm.

The mole fraction of a particular substance is simply the moles of this substance divided by the total
number of moles. In like manner, the weight or mass fraction is the mass of the substance divided by the
total mass. These two compositions, which hold for gases, liquids, and solids, can be expressed as
follows for component A in a mixture:

Equation 1.3-5

Equation 1.3-6

EXAMPLE 1.3-1. Mole and Mass or Weight Fraction of a
Solution
A container holds 50 g of water (B) and 50 g of NaOH (A). Calculate the weight fraction and
mole fraction of NaOH. Also, calculate the lbm of NaOH (A) and H2O (B).

S olu t ion: Taking as a basis for calculation 50 + 50 or 100 g of solution, the following data are
calculated:

Component G Wt Fraction Mol Wt G Moles Mole Fraction

H2 O (B) 50.0 18.02

NaOH (A) 50.0 40.0

Total 100.0 1.000   4.03 1.000

Hence, xA = 0.310 and xB = 0.690 and xA + xB = 0.310 + 0.690 = 1.00. Also, w A + w B = 0.500


+ 0.500 = 1.00. To calculate the lbm of each component, Appendix A.1 gives the conversion
factor of 453.6 g per 1 lbm. Using this,
Note that the g of A in the numerator cancels the g of A in the denominator, leaving lbm of A in
the numerator. The reader is cautioned to put all units down in an equation and cancel those
appearing in the numerator and denominator. In a similar manner we obtain 0.1102 lbm B
(0.0500 kg B).

The analyses of solids and liquids are usually given as weight or mass fraction or weight percent, and
gases as mole fraction or percent. Unless otherwise stated, analyses of solids and liquids will be assumed
to be weight (mass) fraction or percent, and of gases to be mole fraction or percent.

1.3C . C once ntr ation Units for  Liq u id s

In general, when one liquid is mixed with another miscible liquid, the volumes are not additive. Hence,
compositions of liquids are usually not expressed as volume percent of a component but as weight or
mole percent. Another convenient way to express concentrations of components in a solution is molarity,
which is defined as g mol of a component per liter of solution. Other methods used are kg/m3, g/liter,
g/cm3, lb mol/cu ft, lbm/cu ft, and lbm/gallon. All these concentrations depend on temperature, so the
temperature must be specified.

The most common method of expressing total concentration per unit volume is density, kg/m3, g/cm3,
or lbm/ft 3. For example, the density of water at 277.2 K (4°C) is 1000 kg/m3, or 62.43 lbm/ft 3. Sometimes
the density of a solution is expressed as specific gravity, which is defined as the density of the solution at
its given temperature divided by the density of a reference substance at its temperature. If the reference
substance is water at 277.2 K, the specific gravity and density of the substance are numerically equal.
                             
                                                 
                                             
                                               
     

1.4. GAS LAWS AND VAPOR PRESSURE

1.4 A. Pr e ssu r e

There are numerous ways of expressing the pressure exerted by a fluid or system. An absolute pressure of
1.00 atm is equivalent to 760 mm Hg at 0°C, 29.921 in. Hg, 0.760 m Hg, 14.696 lb force per square inch
(psia), or 33.90 ft of water at 4°C. Gage pressure is the pressure above the absolute pressure. Hence, a
pressure of 21.5 lb per square inch gage (psig) is 21.5 + 14.7 (rounded off), or 36.2 psia. In SI units, 1 psia
= 6.89476 × 103 pascal (Pa) = 6.89476 × 103 newtons/m2. Also, 1 atm = 1.01325 × 105 Pa.

In some cases, particularly in evaporation, one may express the pressure as inches of mercury vacuum.
This means the pressure as inches of mercury measured “below” the absolute barometric pressure. For
example, a reading of 25.4 in. Hg vacuum is 29.92 − 25.4, or 4.52 in. Hg absolute pressure. Pressure
conversion units are given in Appendix A.1.

1.4 B. Id e al G as Law

An ideal gas is defined as one that obeys simple laws. Also, in an ideal gas the gas molecules are
considered as rigid spheres which themselves occupy no volume and do not exert forces on one another.
No real gases obey these laws exactly, but at ordinary temperatures and pressures of not more than
several atmospheres, the ideal laws give answers within a few percent or less of the actual answers.
Hence, these laws are sufficiently accurate for engineering calculations.

The ideal gas law of Boyle states that the volume of a gas is directly proportional to the absolute
temperature and inversely proportional to the absolute pressure. This is expressed as

Equation 1.4-1

where p is the absolute pressure in N/m2, V the volume of the gas in m3, n the kg mol of the gas, T the
absolute temperature in K, and R the gas law constant of 8314.3 kg · m2/kg mol · s2 · K. When the volume
is in ft 3, n in lb moles, and T in °R, R has a value of 0.7302 ft 3 · atm/lb mol · °R. For cgs units (see
Appendix A.1), V = cm3, T = K, R = 82.057 cm3 · atm/g mol · K, and n = g mol.

In order that amounts of various gases may be compared, standard conditions of temperature and
pressure (abbreviated STP or SC) are arbitrarily defined as 101.325 kPa (1.0 atm) abs and 273.15 K (0°C).
Under these conditions the volumes are as follows:
EXAMPLE 1.4-1. Gas-Law Constant
Calculate the value of the gas-law constant R when the pressure is in psia, moles in lb mol,
volume in ft 3, and temperature in °R. Repeat for SI units.

S olu t ion: At standard conditions, p = 14.7 psia, V = 359 ft 3, and T = 460 + 32 = 492°R


(273.15 K). Substituting into Eq. (1.4-1) for n = 1.0 lb mol and solving for R,

A useful relation can be obtained from Eq. (1.4-1) for n moles of gas at conditions p1, V1, T1, and also at
conditions p2, V2, T2. Substituting into Eq. (1.4-1),

Combining gives

Equation 1.4-2

1.4 C . Id e al G as M ixtu r e s

Dalton's law for mixtures of ideal gases states that the total pressure of a gas mixture is equal to the sum
of the individual partial pressures:

Equation 1.4-3
where P is total pressure and pA, pB, pC, . . . are the partial pressures of the components A, B, C, . . . in the
mixture.

Since the number of moles of a component is proportional to its partial pressure, the mole fraction of a
component is

Equation 1.4-4

The volume fraction is equal to the mole fraction. Gas mixtures are almost always represented in terms of
mole fractions and not weight fractions. For engineering purposes, Dalton's law is sufficiently accurate to
use for actual mixtures at total pressures of a few atmospheres or less.

EXAMPLE 1.4-2. Composition of a Gas Mixture
A gas mixture contains the following components and partial pressures: CO2, 75 mm Hg; CO,
50 mm Hg; N2, 595 mm Hg; O2, 26 mm Hg. Calculate the total pressure and the composition
in mole fraction.

S olu t ion: Substituting into Eq. (1.4-3),

The mole fraction of CO2 is obtained by using Eq. (1.4-4).

In like manner, the mole fractions of CO, N2, and O2 are calculated as 0.067, 0.797, and
0.035, respectively.

1.4 D. Vap or  Pr e ssu r e  and  Boiling Point of Liq u id s

When a liquid is placed in a sealed container, molecules of liquid will evaporate into the space above the
liquid and fill it completely. After a time, equilibrium is reached. This vapor will exert a pressure just like
a gas and we call this pressure the vapor pressure of the liquid. The value of the vapor pressure is
independent of the amount of liquid in the container as long as some is present.

If an inert gas such as air is also present in the vapor space, it will have very little effect on the vapor
pressure. In general, the effect of total pressure on vapor pressure can be considered as negligible for
pressures of a few atmospheres or less.

The vapor pressure of a liquid increases markedly with temperature. For example, from Appendix A.2 for
water, the vapor pressure at 50°C is 12.333 kPa (92.51 mm Hg). At 100°C the vapor pressure has
increased greatly to 101.325 kPa (760 mm Hg).

The boiling point of a liquid is defined as the temperature at which the vapor pressure of a liquid equals
the total pressure. Hence, if the atmospheric total pressure is 760 mm Hg, water will boil at 100°C. On
top of a high mountain, where the total pressure is considerably less, water will boil at temperatures
below 100°C.

A plot of vapor pressure PA of a liquid versus temperature does not yield a straight line but a curve.
However, for moderate temperature ranges, a plot of log PA versus 1/T is a reasonably straight line, as
follows:

Equation 1.4-5

where m is the slope, b is a constant for the liquid A, and T is the temperature in K.
                             
                                                 
                                             
                                               
     

1.5. CONSERVATION OF MASS AND MATERIAL BALANCES

1.5A. C onse r v ation of M ass

One of the basic laws of physical science is the law of conservation of mass. This law, stated simply, says
that mass cannot be created or destroyed (excluding, of course, nuclear or atomic reactions). Hence, the
total mass (or weight) of all materials entering any process must equal the total mass of all materials
leaving plus the mass of any materials accumulating or left in the process:

Equation 1.5-1

In the majority of cases there will be no accumulation of materials in a process, and then the input will
simply equal the output. Stated in other words, “what goes in must come out.” We call this type of
process a steady-state process:

Equation 1.5-2

1.5B. S im p le  M ate r ial Balance s

In this section we do simple material (weight or mass) balances in various processes at steady state with
no chemical reaction occurring. We can use units of kg, lbm, lb mol, g, kg mol, and so on, in our balances.
The reader is cautioned to be consistent and not to mix several units in a balance. When chemical
reactions occur in the balances (as discussed in Section 1.5D), one should use kg mol units, since
chemical equations relate moles reacting. In Section 2.6, overall mass balances will be covered in more
detail and in Section 3.6, differential mass balances.

To solve a material-balance problem, it is advisable to proceed by a series of definite steps, as listed
below:

1.  Sketch a simple diagram of the process. This can be a simple box diagram showing each stream
entering by an arrow pointing in and each stream leaving by an arrow pointing out. Include on
each arrow the compositions, amounts, temperatures, and so on, of that stream. All pertinent
data should be on this diagram.

2.  Write the chemical equations involved (if any).

3.  Select a basis for calculation. In most cases the problem is concerned with a specific amount of
one of the streams in the process, which is selected as the basis.
4.  Make a material balance. The arrows into the process will be input items and the arrows going
out output items. The balance can be a total material balance in Eq. (1.5-2) or a balance on each
component present (if no chemical reaction occurs).

Typical processes that do not undergo chemical reactions are drying, evaporation, dilution of solutions,
distillation, extraction, and so on. These can be solved by setting up material balances containing
unknowns and solving these equations for the unknowns.

EXAMPLE 1.5-1. Concentration of Orange Juice
In the concentration of orange juice, a fresh extracted and strained juice containing 7.08 wt %
solids is fed to a vacuum evaporator. In the evaporator, water is removed and the solids
content increased to 58 wt % solids. For 1000 kg/h entering, calculate the amounts of the
outlet streams of concentrated juice and water.

S olu t ion: Following the four steps outlined, we make a process flow diagram (step 1) in Fig.
1.5-1. Note that the letter W represents the unknown amount of water and C the amount of
concentrated juice. No chemical reactions are given (step 2). Basis: 1000 kg/h entering juice
(step 3).

Figure 1.5-1. Process flow diagram for Example 1.5-1.

To make the material balances (step 4), a total material balance will be made using Eq. (1.5-2):

Equation 1.5-3

This gives one equation and two unknowns. Hence, a component balance on solids will be
made:

Equation 1.5-4

To solve these two equations, we solve Eq. (1.5-4) first for C since W drops out. We get C =
122.1 kg/h concentrated juice.

Substituting the value of C into Eq. (1.5-3),

and we obtain W = 877.9 kg/h water.

As a check on our calculations, we can write a balance on the water component:

Equation 1.5-5

Solving,

In Example 1.5-1 only one unit or separate process was involved. Often, a number of processes in series
are involved. Then we have a choice of making a separate balance over each separate process and/or a
balance around the complete overall process.

1.5C . M ate r ial Balance s and  R e cycle

Processes that have a recycle or feedback of part of the product into the entering feed are sometimes
encountered. For example, in a sewage treatment plant, part of the activated sludge from a
sedimentation tank is recycled back to the aeration tank where the liquid is treated. In some food-drying
operations, the humidity of the entering air is controlled by recirculating part of the hot, wet air that
leaves the dryer. In chemical reactions, the material that did not react in the reactor can be separated
from the final product and fed back to the reactor.

EXAMPLE 1.5-2. Crystallization of KNO3 and Recycle
In a process producing KNO3 salt, 1000 kg/h of a feed solution containing 20 wt % KNO3 is fed
to an evaporator, which evaporates some water at 422 K to produce a 50 wt % KNO3 solution.
This is then fed to a crystallizer at 311 K, where crystals containing 96 wt % KNO3 are
removed. The saturated solution containing 37.5 wt % KNO3 is recycled to the evaporator.
Calculate the amount of recycle stream R in kg/h and the product stream of crystals P in kg/h.

S olu t ion: Figure 1.5-2 gives the process flow diagram. As a basis we shall use 1000 kg/h of
fresh feed. No chemical reactions are occurring. We can make an overall balance on the entire
process for KNO3 and solve for P directly:

Equation 1.5-6
Figure 1.5-2. Process flow diagram for Example 1.5-2.

To calculate the recycle stream, we can make a balance around the evaporator or the
crystallizer. Using a balance on the crystallizer, since it now includes only two unknowns, S
and R, we get for a total balance,

Equation 1.5-7

For a KNO3 balance on the crystallizer,

Equation 1.5-8

Substituting S from Eq. (1.5-7) into Eq. (1.5-8) and solving, R = 766.6 kg recycle/h and S =
974.9 kg/h.

1.5D. M ate r ial Balance s and  C he m ical R e action

In many cases the materials entering a process undergo chemical reactions in the process, so that the
materials leaving are different from those entering. In these cases it is usually convenient to make a
molar and not a weight balance on an individual component, such as kg mol H2 or kg atom H, kg mol 

 ion, kg mol CaCO3, kg atom Na+, kg mol N2, and so on. For example, in the combustion of CH4
with air, balances can be made on kg mol of H2, C, O2, or N2.
EXAMPLE 1.5-3. Combustion of Fuel Gas
A fuel gas containing 3.1 mol % H2, 27.2% CO, 5.6% CO2, 0.5% O2, and 63.6% N2 is burned
with 20% excess air (i.e., the air over and above that necessary for complete combustion to CO2
and H2O). The combustion of CO is only 98% complete. For 100 kg mol of fuel gas, calculate
the moles of each component in the exit flue gas.

S olu t ion: First, the process flow diagram is drawn (Fig. 1.5-3). On the diagram the
components in the flue gas are shown. Let A be moles of air and F be moles of flue gas. Next the
chemical reactions are given:

Equation 1.5-9

Equation 1.5-10

Figure 1.5-3. Process flow diagram for Example 1.5-3.

An accounting of the total moles of O2 in the fuel gas is as follows:

For all the H2 to be completely burned to H2O, we need, from Eq. (1.5-10),   mol O2 for 1 mol

H2, or 3.1( ) = 1.55 total mol O2. For completely burning the CO from Eq. (1.5-9), we need
27.2( ) = 13.6 mol O2. Hence, the amount of O2 we must add is, theoretically, as follows:

For a 20% excess, we add 1.2(14.65), or 17.58 mol O2. Since air contains 79 mol % N2, the
amount of N2 added is (79/21)(17.58), or 66.1 mol N2.

To calculate the moles in the final flue gas, all the H2 gives H2O, or 3.1 mol H2O. For CO, 2.0%
does not react. Hence, 0.02(27.2), or 0.54 mol CO will be unburned.

A total carbon balance is as follows: inlet moles C = 27.2 + 5.6 = 32.8 mol C. In the outlet flue
gas, 0.54 mol will be as CO and the remainder of 32.8 − 0.54, or 32.26 mol as CO2.

For calculating the outlet mol O2, we make an overall O2 balance:

Equating inlet O2 to outlet, the free remaining O2 = 3.2 mol O2. For the N2 balance, the outlet
= 63.6 (in fuel gas) + 66.1 (in air), or 129.70 mol N2. The outlet flue gas contains 3.10 mol
H2O, 0.54 mol CO, 32.26 mol CO2, 3.20 mol O2, and 129.7 mol N2.

In chemical reactions with several reactants, the limiting reactant component is defined as that
compound which is present in an amount less than the amount necessary for it to react
stoichiometrically with the other reactants. Then the percent completion of a reaction is the amount of
this limiting reactant actually converted, divided by the amount originally present, times 100.
                             
                                                 
                                             
                                               
     

1.6. ENERGY AND HEAT UNITS

1.6 A. Jou le , C alor ie , and  Btu

In a manner similar to that used in making material balances on chemical and biological processes, we
can also make energy balances on a process. Often a large portion of the energy entering or leaving a
system is in the form of heat. Before such energy or heat balances are made, we must understand the
various types of energy and heat units.

In the SI system, energy is given in joules (J) or kilojoules (kJ). Energy is also expressed in btu (British
thermal units) or cal (calories). The g calorie (abbreviated cal) is defined as the amount of heat needed to
heat 1.0 g water 1.0°C (from 14.5°C to 15.5°C). Also, 1 kcal (kilocalorie) = 1000 cal. The btu is defined as
the amount of heat needed to raise 1.0 lb water 1°F. Hence, from Appendix A.1,

Equation 1.6-1

1.6 B. He at C ap acity

The heat capacity of a substance is defined as the amount of heat necessary to increase the temperature
by 1 degree. It can be expressed for 1 g, 1 lb, 1 g mol, 1 kg mol, or 1 lb mol of the substance. For example, a
heat capacity is expressed in SI units as J/kg mol · K; in other units as cal/g · °C, cal/g mol · °C, kcal/kg
mol · °C, btu/lbm · °F, or btu/lb mol · °F.

It can be shown that the actual numerical value of a heat capacity is the same in mass units or in molar
units. That is,

Equation 1.6-2

Equation 1.6-3

For example, to prove this, suppose that a substance has a heat capacity of 0.8 btu/lbm · °F. The
conversion is made using 1.8°F for 1°C or 1 K, 252.16 cal for 1 btu, and 453.6 g for 1 lbm, as follows:
The heat capacities of gases (sometimes called specific heat) at constant pressure cp are functions of
temperature and for engineering purposes can be assumed to be independent of pressure up to several
atmospheres. In most process engineering calculations, one is usually interested in the amount of heat
needed to heat a gas from one temperature t 1 to another at t 2. Since the cp varies with temperature, an
integration must be performed or a suitable mean cpm used. These mean values for gases have been
obtained for T1 of 298 K or 25°C (77°F) and various T2 values, and are tabulated in Table 1.6-1 at 101.325
kPa pressure or less as cpm in kJ/kg mol · K at various values of T2 in K or °C.

Table 1.6-1. Mean Molar Heat Capacities of Gases Between 298 and TK (25 and T°C) at 101.325
kPa or Less (SI Units: c p  =×kJ/kg mol · K)

T(K) T(°C) H2 N2 CO Air O2 H2 O CO2 CH4 SO2

298 25 28.86 29.14 29.16 29.19 29.38 33.59 37.20 35.8 39.9

373 100 28.99 29.19 29.24 29.29 29.66 33.85 38.73 37.6 41.2

473 200 29.13 29.29 29.38 29.40 30.07 34.24 40.62 40.3 42.9

573 300 29.18 29.46 29.60 29.61 30.53 34.39 42.32 43.1 44.5

673 400 29.23 29.68 29.88 29.94 31.01 35.21 43.80 45.9 45.8

773 500 29.29 29.97 30.19 30.25 31.46 35.75 45.12 48.8 47.0
873 600 29.35 30.27 30.52 30.56 31.89 36.33 46.28 51.4 47.9

973 700 29.44 30.56 30.84 30.87 32.26 36.91 47.32 54.0 48.8

1073 800 29.56 30.85 31.16 31.18 32.62 37.53 48.27 56.4 49.6

1173 900 29.63 31.16 31.49 31.48 32.97 38.14 49.15 58.8 50.3
1273 1000 29.84 31.43 31.77 31.79 33.25 38.71 49.91 61.0 50.9
1473 1200 30.18 31.97 32.30 32.32 33.78 39.88 51.29 64.9 51.9

1673 1400 30.51 32.40 32.73 32.76 34.19 40.90 52.34    

EXAMPLE 1.6-1. Heating of N2 Gas
The gas N2 at 1 atm pressure absolute is being heated in a heat exchanger. Calculate the amount of
heat needed in J to heat 3.0 g mol N2 in the following temperature ranges:

a.  298–673 K (25–400°C)

b.  298–1123 K (25–850°C)

c.  673–1123 K (400–850°C)
S olu t ion: For case (a), Table 1.6-1 gives cpm values at 1 atm pressure or less which can be used up
to several atm pressures. For N2 at 673 K, cpm = 29.68 kJ/kg mol · K or 29.68 J/g mol · K. This is
the mean heat capacity for the range 298–673 K:

Equation 1.6-4

Mean Molar Heat Capacities of Gases Between 25 and T°C at 1 atm Pressure or Less (English Units:
c p  =×btu/lb mol · °F)

T(°C) H2 N2 CO Air O2 NO H2 O CO2 HCl Cl2 CH4 SO2 C2 H4 SO3 C2 H6

25 6.894 6.961 6.965 6.972 7.017 7.134 8.024 8.884 6.96 8.12 8.55 9.54 10.45 12.11 12.63
100 6.924 6.972 6.983 6.996 7.083 7.144 8.084 9.251 6.97 8.24 8.98 9.85 11.35 12.84 13.76

200 6.957 6.996 7.017 7.021 7.181 7.224 8.177 9.701 6.98 8.37 9.62 10.25 12.53 13.74 15.27

300 6.970 7.036 7.070 7.073 7.293 7.252 8.215 10.108 7.00 8.48 10.29 10.62 13.65 14.54 16.72

400 6.982 7.089 7.136 7.152 7.406 7.301 8.409 10.462 7.02 8.55 10.97 10.94 14.67 15.22 18.11

500 6.995 7.159 7.210 7.225 7.515 7.389 8.539 10.776 7.06 8.61 11.65 11.22 15.60 15.82 19.39

600 7.011 7.229 7.289 7.299 7.616 7.470 8.678 11.053 7.10 8.66 12.27 11.45 16.45 16.33 20.58
700 7.032 7.298 7.365 7.374 7.706 7.549 8.816 11.303 7.15 8.70 12.90 11.66 17.22 16.77 21.68

800 7.060 7.369 7.443 7.447 7.792 7.630 8.963 11.53 7.21 8.73 13.48 11.84 17.95 17.17 22.72
900 7.076 7.443 7.521 7.520 7.874 7.708 9.109 11.74 7.27 8.77 14.04 12.01 18.63 17.52 23.69

1000 7.128 7.507 7.587 7.593 7.941 7.773 9.246 11.92 7.33 8.80 14.56 12.15 19.23 17.86 24.56

1100 7.169 7.574 7.653 7.660 8.009 7.839 9.389 12.10 7.39 8.82 15.04 12.28 19.81 18.17 25.40

1200 7.209 7.635 7.714 7.719 8.068 7.898 9.524 12.25 7.45 8.94 15.49 12.39 20.33 18.44 26.15
1300 7.252 7.692 7.772 7.778 8.123 7.952 9.66 12.39              

1400 7.288 7.738 7.818 7.824 8.166 7.994 9.77 12.50              


1500 7.326 7.786 7.866 7.873 8.203 8.039 9.89 12.69              

1600 7.386 7.844 7.922 7.929 8.269 8.092 9.95 12.75              

1700 7.421 7.879 7.958 7.965 8.305 8.124 10.13 12.70              


1800 7.467 7.924 8.001 8.010 8.349 8.164 10.24 12.94              
1900 7.505 7.957 8.033 8.043 8.383 8.192 10.34 13.01              

2000 7.548 7.994 8.069 8.081 8.423 8.225 10.43 13.10              


2100 7.588 8.028 8.101 8.115 8.460 8.255 10.52 13.17              

2200 7.624 8.054 8.127 8.144 8.491 8.277 10.61 13.24              


Source: O. A. Hougen, K. W. Watson, and R. A. Ragatz, Chemical Process Principles, Part I, 2nd ed. New
York: John Wiley & Sons, Inc., 1954. With permission.

Substituting the known values,
For case (b), the cpm at 1123 K (obtained by linear interpolation between 1073 and 1173 K) is 31.00
J/g mol · K:

For case (c), there is no mean heat capacity for the interval 673–1123 K. However, we can use the
heat required to heat the gas from 298 to 673 K in case (a) and subtract it from case (b), which
includes the heat to go from 298 to 673 K plus 673 to 1123 K:

Equation 1.6-5

Substituting the proper values into Eq. (1.6-5),

On heating a gas mixture, the total heat required is determined by first calculating the heat required for
each individual component and then adding the results to obtain the total.

The heat capacities of solids and liquids are also functions of temperature and independent of pressure.
Data are given in Appendix A.2, Physical Properties of Water; A.3, Physical Properties of Inorganic and
Organic Compounds; and A.4, Physical Properties of Foods and Biological Materials. More data are
available in (P1).

EXAMPLE 1.6-2. Heating of Milk
Rich cows' milk (4536 kg/h) at 4.4°C is being heated in a heat exchanger to 54.4°C by hot
water. How much heat is needed?

S olu t ion: From Appendix A.4, the average heat capacity of rich cows' milk is 3.85 kJ/kg · K.
Temperature rise ΔT = (54.4 − 4.4)°C = 50 K.

The enthalpy, H, of a substance in J/kg represents the sum of the internal energy plus the pressure–
volume term. For no reaction and a constant-pressure process with a change in temperature, the heat
change as computed from Eq. (1.6-4) is the difference in enthalpy, ΔH, of the substance relative to a
given temperature or base point. In other units, H = btu/lbm or cal/g.

1.6 C . Late nt He at and  S te am  Tab le s

Whenever a substance undergoes a change of phase, relatively large amounts of heat change are involved
at a constant temperature. For example, ice at 0°C and 1 atm pressure can absorb 6013.4 kJ/kg mol. This
enthalpy change is called the latent heat of fusion. Data for other compounds are available in various
handbooks (P1, W1).

When a liquid phase vaporizes to a vapor phase under its vapor pressure at constant temperature, an
amount of heat called the latent heat of vaporization must be added. Tabulations of latent heats of
vaporization are given in various handbooks. For water at 25°C and a pressure of 23.75 mm Hg, the
latent heat is 44 020 kJ/kg mol, and at 25°C and 760 mm Hg, 44 045 kJ/kg mol. Hence, the effect of
pressure can be neglected in engineering calculations. However, there is a large effect of temperature on
the latent heat of water. Also, the effect of pressure on the heat capacity of liquid water is small and can
be neglected.

Since water is a very common chemical, the thermodynamic properties of it have been compiled in steam
tables and are given in Appendix A.2 in SI and in English units.

EXAMPLE 1.6-3. Use of Steam Tables
Find the enthalpy change (i.e., how much heat must be added) for each of the following cases
using SI and English units:

a.  Heating 1 kg (lbm) water from 21.11°C (70°F) to 60°C (140°F) at 101.325 kPa (1 atm)
pressure.

b.  Heating 1 kg (lbm) water from 21.11°C (70°F) to 115.6°C (240°F) and vaporizing at
172.2 kPa (24.97 psia).

c.  Vaporizing 1 kg (lbm) water at 115.6°C (240°F) and 172.2 kPa (24.97 psia).

S olu t ion: For part (a), the effect of pressure on the enthalpy of liquid water is negligible. From
Appendix A.2,

In part (b), the enthalpy at 115.6°C (240°F) and 172.2 kPa (24.97 psia) of the saturated vapor
is 2699.9 kJ/kg or 1160.7 btu/lbm.
The latent heat of water at 115.6°C (240°F) in part (c) is

1.6 D. He at of R e action

When chemical reactions occur, heat effects always accompany these reactions. This area where energy
changes occur is often called thermochemistry. For example, when HCl is neutralized with NaOH, heat is
given off and the reaction is exothermic. Heat is absorbed in an endothermic reaction. This heat of
reaction is dependent on the chemical nature of each reacting material and product and on their physical
states.

For purposes of organizing data, we define a standard heat of reaction ΔH0 as the change in enthalpy
when 1 kg mol reacts under a pressure of 101.325 kPa at a temperature of 298 K (25°C). For example, for
the reaction

Equation 1.6-6

the ΔH0 is −285.840 × 103 kJ/kg mol or −68.317 kcal/g mol. The reaction is exothermic and the value is
negative since the reaction loses enthalpy. In this case, the H2 gas reacts with the O2 gas to give liquid
water, all at 298 K (25°C).

Special names are given to ΔH0 depending upon the type of reaction. When the product is formed from

the elements, as in Eq. (1.6-6), we call the ΔH0 the heat of formation of the product water,  . For

the combustion of CH4 to form CO2 and H2O, we call it heat of combustion,  . Data are given in

Appendix A.3 for various values of  .

EXAMPLE 1.6-4. Combustion of Carbon
A total of 10.0 g mol of carbon graphite is burned in a calorimeter held at 298 K and 1 atm. The
combustion is incomplete, and 90% of the C goes to CO2 and 10% to CO. What is the total
enthalpy change in kJ and kcal?

S olu t ion: From Appendix A.3 the   for carbon going to CO2 is −393.513 × 103 kJ/kg mol


or −94.0518 kcal/g mol, and for carbon going to CO it is −110.523 × 103 kJ/kg mol or
−26.4157 kcal/g mol. Since 9 mol CO2 and 1 mol CO are formed,

If a table of heats of formation,   of compounds is available, the standard heat of the reaction, ΔH0,
can be calculated by

Equation 1.6-7

In Appendix A.3, a short table of some values of ΔHf is given. Other data are also available (H1, P1, S1).

EXAMPLE 1.6-5. Reaction of Methane
For the following reaction of 1 kg mol of CH4 at 101.32 kPa and 298 K,

calculate the standard heat of reaction ΔH0 at 298 K in kJ.

S olu t ion: From Appendix A.3, the following standard heats of formation are obtained at 298
K:

   ( )
kJ/kg mol

CH4 (g) −74.848 × 103

H2 O(l) −285.840 × 103

CO(g) −110.523 × 103

H2 (g) 0

Note that the   of all elements is, by definition, zero. Substituting into Eq. (1.6-7),
                             
                                                 
                                             
                                               
     

1.7. CONSERVATION OF ENERGY AND HEAT BALANCES

1.7A. C onse r v ation of Ene r gy

In making material balances we used the law of conservation of mass, which states that the mass
entering is equal to the mass leaving plus the mass left in the process. In a similar manner, we can state
the law of conservation of energy, which says that all energy entering a process is equal to that leaving
plus that left in the process. In this section elementary heat balances will be made. More elaborate energy
balances will be considered in Sections 2.7 and 5.6.

Energy can appear in many forms. Some of the common forms are enthalpy, electrical energy, chemical
energy (in terms of ΔH reaction), kinetic energy, potential energy, work, and heat inflow.

In many cases in process engineering, which often takes place at constant pressure, electrical energy,
kinetic energy, potential energy, and work either are not present or can be neglected. Then only the
enthalpy of the materials (at constant pressure), the standard chemical reaction energy (ΔH0) at 25°C,
and the heat added or removed must be taken into account in the energy balance. This is generally called
a heat balance.

1.7B. He at Balance s

In making a heat balance at steady state we use methods similar to those used in making a material
balance. The energy or heat coming into a process in the inlet materials plus any net energy added to the
process are equal to the energy leaving in the materials. Expressed mathematically,

Equation 1.7-1

where ΣHR is the sum of enthalpies of all materials entering the reaction process relative to the reference
state for the standard heat of reaction at 298 K and 101.32 kPa. If the inlet temperature is above 298 K,

this sum will be positive.   = standard heat of the reaction at 298 K and 101.32 kPa. The reaction

contributes heat to the process, so the negative of   is taken to be positive input heat for an
exothermic reaction. Also, q = net energy or heat added to the system. If heat leaves the system, this item
will be negative. ΣHp = sum of enthalpies of all leaving materials referred to the standard reference state
at 298 K (25°C).

Note that if the materials coming into a process are below 298 K, ΣHR will be negative. Care must be
taken not to confuse the signs of the items in Eq. (1.7-1). If no chemical reaction occurs, then simple
heating, cooling, or phase change is occurring. Use of Eq. (1.7-1) will be illustrated by several examples.
For convenience it is common practice to call the terms on the left-hand side of Eq. (1.7-1) input items,
and those on the right, output items.

EXAMPLE 1.7-1. Heating of Fermentation Medium
A liquid fermentation medium at 30°C is pumped at a rate of 2000 kg/h through a heater,
where it is heated to 70°C under pressure. The waste heat water used to heat this medium
enters at 95°C and leaves at 85°C. The average heat capacity of the fermentation medium is
4.06 kJ/kg · K, and that for water is 4.21 kJ/kg · K (Appendix A.2). The fermentation stream
and the wastewater stream are separated by a metal surface through which heat is transferred
and do not physically mix with each other. Make a complete heat balance on the system.
Calculate the water flow and the amount of heat added to the fermentation medium assuming
no heat losses. The process flow is given in Fig. 1.7-1.

Figure 1.7-1. Process flow diagram for Example 1.7-1.

S olu t ion: It is convenient to use the standard reference state of 298 K (25°C) as the datum to
calculate the various enthalpies. From Eq. (1.7-1) the input items are as follows:

Input items. ΣHR of the enthalpies of the two streams relative to 298 K (25°C) (note that Δt =
30 − 25°C = 5°C = 5 K):

Output items. ΣHp of the two streams relative to 298 K (25°C):
Equating input to output in Eq. (1.7-1) and solving for W,

The amount of heat added to the fermentation medium is simply the difference of the outlet
and inlet liquid enthalpies:

Note in this example that since the heat capacities were assumed constant, a simpler balance
could have been written as follows:

Then, solving, W = 7720 kg/h. This simple balance works well when cp is constant. However,
when cp varies with temperature and the material is a gas, cpm values are only available
between 298 K (25°C) and t K, and the simple method cannot be used without obtaining new
cpm values over different temperature ranges.

EXAMPLE 1.7-2. Heat and Material Balance in Combustion
The waste gas from a process of 1000 g mol/h of CO at 473 K is burned at 1 atm pressure in a
furnace using air at 373 K. The combustion is complete and 90% excess air is used. The flue
gas leaves the furnace at 1273 K. Calculate the heat removed in the furnace.

S olu t ion: First, the process flow diagram is drawn in Fig. 1.7-2, and then a material balance
is made:
Figure 1.7-2. Process flow diagram for Example 1.7-2.

For the heat balance relative to the standard state at 298 K, we follow Eq. (1.7-1).

Input items

(The cpm of CO of 29.38 kJ/kg molK between 298 and 473 K is obtained from Table 1.6-1.)
(This will give a negative value here, indicating that heat was removed.)

Output items

Equating input to output and solving for q,

Hence, heat is removed: −34 837 W.

Often when chemical reactions occur in the process and the heat capacities vary with temperature, the
solution in a heat balance can be trial and error if the final temperature is the unknown.

EXAMPLE 1.7-3. Oxidation of Lactose
In many biochemical processes, lactose is used as a nutrient, which is oxidized as follows:

The heat of combustion   in Appendix A.3 at 25°C is −5648.8 × 103 J/g mol. Calculate
the heat of complete oxidation (combustion) at 37°C, which is the temperature of many
biochemical reactions. The cpm of solid lactose is 1.20 J/g · K, and the molecular weight is
342.3 g mass/g mol.

S olu t ion: This can be treated as an ordinary heat-balance problem. First, the process flow
diagram is drawn in Fig. 1.7-3. Next, the datum temperature of 25°C is selected and the input
and output enthalpies calculated. The temperature difference Δt = (37 − 25)°C = (37 − 25) K.

Figure 1.7-3. Process flow diagram for Example 1.7-3.
Input items

(The cpm of O2 was obtained from Table 1.6-1.)

Output items

(The cpm of liquid water was obtained from Appendix A.2.)

(The cpm of CO2 is obtained from Table 1.6-1.)

ΔH37°C:

Setting input = output and solving,
                             
                                                 
                                             
                                               
     

1.8. NUMERICAL METHODS FOR INTEGRATION

1.8A. Intr od u ction and  G r ap hical Inte gr ation

Often the mathematical function f(x) to be integrated is too complex and we are not able to integrate it
analytically. Or in some cases the function is one that has been obtained from experimental data, and no
mathematical equation is available to represent the data so that they can be integrated analytically. In
these cases, we can use either numerical or graphical integration.

Integration of a function f(x) between the limits x = a to x = b can be represented by

Equation 1.8-1

By graphically plotting f(x) versus x, the area under the curve is equal to the value of the integral.

1.8B. Nu m e r ical Inte gr ation and  S im p son's R u le

Often it is desirable or necessary to perform a numerical integration by computing the value of a definite
integral from a set of numerical values of the integrand f(x). This, of course, can be done graphically, but
in most cases numerical methods suitable for the digital computer are desired.

The integral to be evaluated is Eq. (1.8-1), where the interval is b − a. The most generally used numerical
method is the parabolic rule, often called Simpson's rule. This method divides the total interval b − a
into an even number of subintervals m, where

Equation 1.8-2

The value of h, a constant, is the spacing in x used. Then, approximating f(x) by a parabola on each
subinterval, Simpson's rule is

Equation 1.8-3
where f0 is the value of f(x) at x = a; f1 the value of f(x) at x = x1, . . . ; fm the value of f(x) at x = b. The
reader should note that m must be an even number and the increments evenly spaced. This method is
well suited for digital computation with a spreadsheet. Spreadsheets have numerical calculation
methods built into their programs. Simpson's rule is a widely used numerical integration method.

In some cases the available experimental data for f(x) are not at equally spaced increments of x. Then the
numerical integration can be performed using the sum of the single-interval rectangles (trapezoidal rule)
for the value of the interval. This is much less accurate than Simpson's rule. The trapezoidal-rule method
becomes more accurate as the interval becomes smaller.

Sometimes the experimental data for f(x) are spaced at large and/or irregular increments of x. These data
can be smoothed by fitting a polynomial, exponential, logarithmic, or some other function to the data,
which often can be integrated analytically. If the function is relatively complex, then it can be
numerically integrated using Simpson's rule. All of this can be done using Excel and a spreadsheet.
                             
                                                 
                                             
                                               
     

PROBLEMS
1.2-1.
Temp er a t u r e of a  C he mica l Pr ocess. The temperature of a chemical reaction was found to
be 353.2 K. What is the temperature in °F, °C, and °R?
A1:Ans. 176°F, 80°C, 636°R
1.2-2.
Temp er a t u r e for  S mok eho u se Pr ocessing  of M ea t . In smokehouse processing of sausage
meat, a final temperature of 155°F inside the sausage is often used. Calculate this temperature in
°C, K, and °R.
1.3-1.
M olecu la r  W eig ht  of Air . For purposes of most engineering calculations, air is assumed to be
composed of 21 mol % oxygen and 79 mol % nitrogen. Calculate the average molecular weight.
A3:Ans. 28.9 g mass/g mol, lb mass/lb mol, or kg mass/kg mol
1.3-2.
Oxid a t ion of C O a nd  M ole Unit s. The gas CO is being oxidized by O2 to form CO2. How
many kg of CO2 will be formed from 56 kg of CO? Also, calculate the kg of O2 theoretically
needed for this reaction. (Hint: First write the balanced chemical equation to obtain the mol O2
needed for 1.0 kg mol CO. Then calculate the kg mol of CO in 56 kg CO.)
A4 :Ans. 88.0 kg CO2, 32.0 kg O2
1.3-3.
C omp osit ion of a  G a s M ixt u r e. A gaseous mixture contains 20 g of N2, 83 g of O2, and 45 g
of CO2. Calculate the composition in mole fraction and the average molecular weight of the
mixture.
A5:Ans. Average mol wt = 34.2 g mass/g mol, 34.2 kg mass/kg mol
1.3-4 .
C omp osit ion of a  Pr ot ein S olu t ion. A liquid solution contains 1.15 wt % of a protein, 0.27
wt % KCl, and the remainder water. The average molecular weight of the protein by gel
permeation is 525000 g mass/g mol. Calculate the mole fraction of each component in solution.
1.3-5.
C oncent r a t ion of Na C l S olu t ion. An aqueous solution of NaCl has a concentration of 24.0
wt % NaCl with a density of 1.178 g/cm3 at 25°C. Calculate the following.

a.  Mole fraction of NaCl and water.

b.  Concentration of NaCl as g mol/liter, lbm/ft 3, lbm/gal, and kg/m3.

1.4 -1.
C onv er sion of Pr essu r e M ea su r ement s in Fr eeze Dr y ing . In the experimental
measurement of freeze drying of beef, an absolute pressure of 2.4 mm Hg was held in the
chamber. Convert this pressure to atm, in. of water at 4°C, μm of Hg, and Pa. (Hint: See
Appendix A.1 for conversion factors.)

A8: Ans.  3.16 × 10−3 atm, 1.285 in. H O, 2400 μm Hg, 320 Pa


2
1.4 -2.
C omp r ession a nd  C ooling  of Nit r og en G a s. A volume of 65.0 ft 3 of N2 gas at 90°F and
29.0 psig is compressed to 75 psig and cooled to 65°F. Calculate the final volume in ft 3 and the
final density in lbm/ft 3. [Hint: Be sure to convert all pressures to psia first and then to atm.
Substitute original conditions into Eq. (1.4-1) to obtain n, lb mol.]
1.4 -3.
G a s C omp osit ion a nd  Volu me. A gas mixture of 0.13 g mol NH3, 1.27 g mol N2, and 0.025 g
mol H2O vapor is contained at a total pressure of 830 mm Hg and 323 K. Calculate the
following.

a.  Mole fraction of each component.

b.  Partial pressure of each component in mm Hg.

c.  Total volume of mixture in m3 and ft 3.

1.4 -4 .
Ev a p or a t ion of a  Hea t -S ensit iv e Or g a nic Liq u id . An organic liquid is being evaporated
from a liquid solution containing a few percent nonvolatile dissolved solids. Since it is heat-
sensitive and may discolor at high temperatures, it will be evaporated under vacuum. If the
lowest absolute pressure that can be obtained in the apparatus is 12.0 mm Hg, what will be the
temperature of evaporation in K? It will be assumed that the small amount of solids does not
affect the vapor pressure, which is given as follows:

where PA is in mm Hg and T in K.
A11:Ans. T = 282.3 K or 9.1°C
1.5-1.
Ev a p or a t ion of C a ne S u g a r  S olu t ions. An evaporator is used to concentrate cane sugar
solutions. A feed of 10 000 kg/d of a solution containing 38 wt % sugar is evaporated, producing
a 74 wt % solution. Calculate the weight of solution produced and amount of water removed.
A12:Ans. 5135 kg/d of 74 wt % solution, 4865 kg/d water
1.5-2.
Pr ocessing  of Fish M ea l. Fish are processed into fish meal and used as a supplementary
protein food. In the processing the oil is first extracted to produce wet fish cake containing 80 wt
% water and 20 wt % bone-dry cake. This wet cake feed is dried in rotary-drum dryers to give a
“dry” fish cake product containing 40 wt % water. Finally, the product is finely ground and
packed. Calculate the kg/h of wet cake feed needed to produce 1000 kg/h of “dry” fish cake
product.
A13:Ans. 3000 kg/h wet cake feed
1.5-3.
Dr y ing  of Lu mb er . A batch of 100 kg of wet lumber containing 11 wt % moisture is dried to a
water content of 6.38 kg water/1.0 kg bone-dry lumber. What is the weight of “dried” lumber and
the amount of water removed?
1.5-4 .
Pr ocessing  of Pa p er  Pu lp . A wet paper pulp contains 68 wt % water. After the pulp was
dried, it was found that 55% of the original water in the wet pulp was removed. Calculate the
composition of the “dried” pulp and its weight for a feed of 1000 kg/min of wet pulp.
1.5-5.
Pr od u ct ion of Ja m fr om C r u shed  Fr u it  in Tw o S t a g es. In a process producing jam (C1),
crushed fruit containing 14 wt % soluble solids is mixed in a mixer with sugar (1.22 kg
sugar/1.00 kg crushed fruit) and pectin (0.0025 kg pectin/1.00 kg crushed fruit). The resultant
mixture is then evaporated in a kettle to produce a jam containing 67 wt % soluble solids. For a
feed of 1000 kg crushed fruit, calculate the kg mixture from the mixer, kg water evaporated, and
kg jam produced.
A16 :Ans. 2222.5 kg mixture, 189 kg water, 2033.5 kg jam
1.5-6 .
Dr y ing  of C a ssa v a  (Ta p ioca ) R oot . Tapioca flour is used in many countries for bread and
similar products. The flour is made by drying coarse granules of the cassava root containing 66
wt % moisture to 5% moisture and then grinding to produce a flour. How many kg of granules
must be dried and how much water removed to produce 5000 kg/h of flour?
1.5-7.
Pr ocessing  of S oy b ea ns in Thr ee S t a g es. A feed of 10 000 kg of soybeans is processed in a
sequence of three stages or steps (E1). The feed contains 35 wt % protein, 27.1 wt %
carbohydrate, 9.4 wt % fiber and ash, 10.5 wt % moisture, and 18.0 wt % oil. In the first stage
the beans are crushed and pressed to remove oil, giving an expressed-oil stream and a stream of
pressed beans containing 6% oil. Assume no loss of other constituents with the oil stream. In the
second step the pressed beans are extracted with hexane to produce an extracted-meal stream
containing 0.5 wt % oil and a hexane–oil stream. Assume no hexane in the extracted meal.
Finally, in the last step the extracted meal is dried to give a dried meal of 8 wt % moisture.
Calculate:

a.  Kg of pressed beans from the first stage.

b.  Kg of extracted meal from stage 2.

c.  Kg of final dried meal and the wt % protein in the dried meal.

A18:Ans. (a) 8723 kg; (b) 8241 kg; (c) 7816 kg, 44.8 wt % protein
1.5-8.
R ecy cle in a  Dr y er . A solid material containing 15.0 wt % moisture is dried so that it contains
7.0 wt % water by blowing fresh warm air mixed with recycled air over the solid in the dryer. The
inlet fresh air has a humidity of 0.01 kg water/kg dry air, the air from the drier that is recycled
has a humidity of 0.1 kg water/kg dry air, and the mixed air to the dryer, 0.03 kg water/kg dry
air. For a feed of 100 kg solid/h fed to the dryer, calculate the kg dry air/h in the fresh air, the kg
dry air/h in the recycled air, and the kg/h of “dried” product.
A19 :Ans. 95.6 kg/h dry air in fresh air, 27.3 kg/h dry air in recycled air, and 91.4 kg/h “dried”
product
1.5-9 .
C r y st a lliza t ion a nd  R ecy cle. It is desired to produce 1000 kg/h of Na3PO4 · 12H2O crystals
from a feed solution containing 5.6 wt % Na3PO4 and traces of impurity. The original solution is
first evaporated in an evaporator to a 35 wt % Na3PO4 solution and then cooled to 293 K in a
crystallizer, where the hydrated crystals and a mother-liquor solution are removed. One out of
every 10 kg of mother liquor is discarded to waste to get rid of the impurities, and the remaining
mother liquor is recycled to the evaporator. The solubility of Na3PO4 at 293 K is 9.91 wt %.
Calculate the kg/h of feed solution and kg/h of water evaporated.
A20:Ans. 7771 kg/h feed, 6739 kg/h water
1.5-10.
Ev a p or a t ion a nd  By p a ss in Or a ng e Ju ice C oncent r a t ion. In a process for concentrating
1000 kg of freshly extracted orange juice (C1) containing 12.5 wt % solids, the juice is strained,
yielding 800 kg of strained juice and 200 kg of pulpy juice. The strained juice is concentrated in
a vacuum evaporator to give an evaporated juice of 58% solids. The 200 kg of pulpy juice is
bypassed around the evaporator and mixed with the evaporated juice in a mixer to improve the
flavor. This final concentrated juice contains 42 wt % solids. Calculate the concentration of
solids in the strained juice, the kg of final concentrated juice, and the concentration of solids in
the pulpy juice bypassed. (Hint: First, make a total balance and then a solids balance on the
overall process. Next, make a balance on the evaporator. Finally, make a balance on the mixer.)
A21:Ans. 34.2 wt % solids in pulpy juice
1.5-11.
M a nu fa ct u r e of Acet y lene. For the making of 6000 ft 3 of acetylene (CHCH) gas at 70°F and
750 mm Hg, solid calcium carbide (CaC 2) which contains 97 wt % CaC 2 and 3 wt % solid inerts
is used along with water. The reaction is

The final lime slurry contains water, solid inerts, and Ca(OH)2 lime. In this slurry the total wt %
solids of inerts plus Ca(OH)2 is 20%. How many lb of water must be added and how many lb of
final lime slurry is produced? [Hint:  Use a basis of 6000 ft 3 and convert to lb mol. This gives
15.30 lb mol C 2H2, 15.30 lb mol Ca(OH)2, and 15.30 lb mol CaC 2 added. Convert lb mol CaC 2
feed to lb and calculate lb inerts added. The total lb solids in the slurry is then the sum of the
Ca(OH)2 plus inerts. In calculating the water added, remember that some is consumed in the
reaction.]
A22:Ans. 5200 lb water added (2359 kg), 5815 lb lime slurry (2638 kg)
1.5-12.
C omb u st ion of S olid  Fu el. A fuel analyzes 74.0 wt % C and 12.0% ash (inert). Air is added to
burn the fuel, producing a flue gas of 12.4% CO2, 1.2% CO, 5.7% O2, and 80.7% N2. Calculate the
kg of fuel used for 100 kg mol of outlet flue gas and the kg mol of air used. (Hint: First calculate
the mol O2 added in the air, using the fact that the N2 in the flue gas equals the N2 added in the
air. Then make a carbon balance to obtain the total moles of C added.)
1.5-13.
Bu r ning  of C ok e. A furnace burns a coke containing 81.0 wt % C, 0.8% H, and the rest inert
ash. The furnace uses 60% excess air (air over and above that needed to burn all C to CO2 and H
to H2O). Calculate the moles of all components in the flue gas if only 95% of the carbon goes to
CO2 and 5% to CO.
1.5-14 .
Pr od u ct ion of For ma ld ehy d e. Formaldehyde (CH2O) is made by the catalytic oxidation of
pure methanol vapor and air in a reactor. The moles from this reactor are 63.1 N2, 13.4 O2, 5.9
H2O, 4.1 CH2O, 12.3 CH3OH, and 1.2 HCOOH. The reaction is

A side reaction occurring is

Calculate the mol methanol feed, mol air feed, and percent conversion of methanol to
formaldehyde.
A25:Ans. 17.6 mol CH3OH, 79.8 mol air, 23.3% conversion
1.6 -1.
Hea t ing  of C O 2  G a s. A total of 250 g of CO2 gas at 373 K is heated to 623 K at 101.32 kPa total
pressure. Calculate the amount of heat needed in cal, btu, and kJ.
A26 :Ans. 15 050 cal, 59.7 btu, 62.98 kJ
1.6 -2.
Hea t ing  a  G a s M ixt u r e. A mixture of 25 lb mol N2 and 75 lb mol CH4 is being heated from
400°F to 800°F at 1 atm pressure. Calculate the total amount of heat needed in btu.
1.6 -3.
Fina l Temp er a t u r e in Hea t ing  Ap p lesa u ce. A mixture of 454 kg of applesauce at 10°C is
heated in a heat exchanger by adding 121 300 kJ. Calculate the outlet temperature of the
applesauce. (Hint: In Appendix A.4 a heat capacity for applesauce is given at 32.8°C. Assume
that this is constant and use this as the average cpm.)
A28:Ans. 76.5°C

1.6 -4 .
Use of S t ea m Ta b les. Using the steam tables, determine the enthalpy change for 1 lb water for
each of the following cases:

a.  Heating liquid water from 40°F to 240°F at 30 psia. (Note that the effect of total pressure
on the enthalpy of liquid water can be neglected.)

b.  Heating liquid water from 40°F to 240°F and vaporizing at 240°F and 24.97 psia.

c.  Cooling and condensing a saturated vapor at 212°F and 1 atm abs to a liquid at 60°F.

d.  Condensing a saturated vapor at 212°F and 1 atm abs.

A29 :Ans. (a) 200.42 btu/lbm; (b) 1152.7 btu/lbm; (c) −1122.4 btu/lbm; (d) −970.3 btu/lbm, −2256.9
kJ/kg
1.6 -5.
Hea t ing  a nd  Va p or iza t ion Using  S t ea m Ta b les. A flow rate of 1000 kg/h of water at
21.1°C is heated to 110°C when the total pressure is 244.2 kPa in the first stage of a process. In
the second stage at the same pressure the water is heated further, until it is all vaporized at its
boiling point. Calculate the total enthalpy change in the first stage and in both stages.
1.6 -6 .
C omb u st ion of C H 4  a nd  H 2 . For 100 g mol of a gas mixture of 75 mol % CH4 and 25% H2,
calculate the total heat of combustion of the mixture at 298 K and 101.32 kPa, assuming that
combustion is complete.
1.6 -7.
Hea t  of R ea ct ion fr om Hea t s of For ma t ion. For the reaction

calculate the heat of reaction, ΔH, at 298 K and 101.32 kPa for 4 g mol of NH3 reacting.
A32:Ans. ΔH, heat of reaction = −904.7 kJ
1.7-1.
Hea t  Ba la nce a nd  C ooling  of M ilk . In the processing of rich cows' milk, 4540 kg/h of milk
is cooled from 60°C to 4.44°C by a refrigerant. Calculate the heat removed from the milk.
A33:Ans. Heat removed = 269.6 kW
1.7-2.
Hea t ing  of Oil b y  Air . A flow of 2200 lbm/h of hydrocarbon oil at 100°F enters a heat
exchanger, where it is heated to 150°F by hot air. The hot air enters at 300°F and is to leave at
200°F. Calculate the total lb mol air/h needed. The mean heat capacity of the oil is 0.45 btu/lbm
· °F.
A34 :Ans. 70.1 lb mol air/h, 31.8 kg mol/h
1.7-3.
C omb u st ion of M et ha ne in a  Fu r na ce. A gas stream of 10 000 kg mol/h of CH4 at 101.32
kPa and 373 K is burned in a furnace using air at 313 K. The combustion is complete and 50%
excess air is used. The flue gas leaves the furnace at 673 K. Calculate the heat removed in the
furnace. (Hint: Use a datum of 298 K and liquid water at 298 K. The input items will be the
following: the enthalpy of CH4 at 373 K referred to 298 K; the enthalpy of the air at 313 K referred

to 298 K; −  the heat of combustion of CH4 at 298 K, which is referred to liquid water; and
q, the heat added. The output items will include: the enthalpies of CO2, O2, N2, and H2O gases
at 673 K referred to 298 K; and the latent heat of H2O vapor at 298 K and 101.32 kPa from
Appendix A.2. It is necessary to include this latent heat since the basis of the calculation and of

the   is liquid water.)

1.7-4 .
Pr ehea t ing  Air  b y  S t ea m for  Use in a  Dr y er . An air stream at 32.2°C is to be used in a
dryer and is first preheated in a steam heater, where it is heated to 65.5°C. The air flow is 1000
kg mol/h. The steam enters the heater saturated at 148.9°C, is condensed and cooled, and leaves
as a liquid at 137.8°C. Calculate the amount of steam used in kg/h.
A36 :Ans. 450 kg steam/h
1.7-5.
C ooling  of C a ns of Pot a t o S ou p  Aft er  Ther ma l Pr ocessing . A total of 1500 cans of potato
soup undergo thermal processing in a retort at 240°F. The cans are then cooled to 100°F in the
retort before being removed from the retort by cooling water, which enters at 75°F and leaves at
85°F. Calculate the lb of cooling water needed. Each can of soup contains 1.0 lb of liquid soup,
and the empty metal can weighs 0.16 lb. The mean heat capacity of the soup is 0.94 btu/lbm · °F
and that of the metal can is 0.12 btu/lbm · °F. A metal rack or basket which is used to hold the
cans in the retort weighs 350 lb and has a heat capacity of 0.12 btu/lbm · °F. Assume that the
metal rack is cooled from 240°F to 85°F, the temperature of the outlet water. The amount of heat
removed from the retort walls in cooling from 240 to 100°F is 10 000 btu. Radiation loss from
the retort during cooling is estimated as 5000 btu.
A37:Ans. 21 320 lb water, 9670 kg
1.8-1.
Nu mer ica l Int eg r a t ion Using  S imp son's M et hod . The following experimental data for y
= f(x) were obtained:

x f(x) x f(x)

0 100 0.4 53

0.1 75 0.5 60
0.2 60.5 0.6 72.5

0.3 53.5    
Determine the integral using Simpson's method:

A38:Ans. A = 38.45
1.8-2.
Nu mer ica l Int eg r a t ion t o Ob t a in W a st ew a t er  Flow . The rate of flow of wastewater in an
open channel has been measured and the following data obtained:

Time (min) Flow (m 3 /min) Time (min) Flow (m 3 /min)

0 655 70 800
10 705 80 725

20 780 90 670
30 830 100 640

40 870 110 620

50 890 120 610

60 870    

Determine the total flow in m3 for 120 min by numerical integration.
A39 : Ans.  92 350 m3
                             
                                                 
                                             
                                               
     

Chapter 2. Principles of Momentum Transfer and Overall
Balances
                             
                                                 
                                             
                                               
     

2.1. INTRODUCTION
The flow and behavior of fluids is important in many of the separation processes in process engineering.
A fluid may be defined as a substance that does not permanently resist distortion and, hence, will change
its shape. In this text gases, liquids, and vapors are considered to have the characteristics of fluids and to
obey many of the same laws.

In the process industries, many of the materials are in fluid form and must be stored, handled, pumped,
and processed, so it is necessary that we become familiar with the principles that govern the flow of fluids
as well as with the equipment used. Typical fluids encountered include water, air, CO2, oil, slurries, and
thick syrups.

If a fluid is inappreciably affected by changes in pressure, it is said to be incompressible. Most liquids are
incompressible. Gases are considered to be compressible fluids. However, if gases are subjected to small
percentage changes in pressure and temperature, their density changes will be small and they can be
considered to be incompressible.

Like all physical matter, a fluid is composed of an extremely large number of molecules per unit volume.
A theory such as the kinetic theory of gases or statistical mechanics treats the motions of molecules in
terms of statistical groups and not in terms of individual molecules. In engineering we are mainly
concerned with the bulk or macroscopic behavior of a fluid rather than the individual molecular or
microscopic behavior.

In momentum transfer we treat the fluid as a continuous distribution of matter, or a “continuum.” This
treatment as a continuum is valid when the smallest volume of fluid contains a number of molecules
large enough that a statistical average is meaningful and the macroscopic properties of the fluid, such as
density, pressure, and so on, vary smoothly or continuously from point to point.

The study of momentum transfer, or fluid mechanics as it is often called, can be divided into two
branches: fluid statics, or fluids at rest, and fluid dynamics, or fluids in motion. In Section 2.2 we treat
fluid statics; in the remaining sections of Chapter 2 and in Chapter 3, fluid dynamics. Since in fluid
dynamics momentum is being transferred, the term “momentum transfer” or “transport” is usually used.
In Section 2.3 momentum transfer is related to heat and mass transfer.
                             
                                                 
                                             
                                               
     

2.2. FLUID STATICS

2.2A. For ce , Units, and  Dim e nsions

In a static fluid an important property is the pressure in the fluid. Pressure is familiar as a surface force
exerted by a fluid against the walls of its container. Also, pressure exists at any point in a volume of a
fluid.

In order to understand pressure, which is defined as force exerted per unit area, we must first discuss a
basic law of Newton's. This equation for calculation of the force exerted by a mass under the influence of
gravity is

Equation 2.2-1

where in SI units F is the force exerted in newtons N (kg · m/s2), m the mass in kg, and g the standard
acceleration of gravity, 9.80665 m/s2.

In English units, F is in lbf, m in lbm, g is 32.1740 ft/s2, and g c (a gravitational conversion factor) is

32.174 lbm · ft/lbf · s2. The use of the conversion factor g c means that g/g c has a value of 1.0 lbf/lbm and


that 1 lbm conveniently gives a force equal to 1 lbf. Often when units of pressure are given, the word

“force” is omitted, as in lb/in. 2 (psi) instead of lbf/in. 2. When the mass m is given in g mass, F is g force,

g = 980.665 cm/s2, and g c = 980.665 g mass · cm/g force · s2. However, the units g force are seldom
used.

Another system of units sometimes used in Eq. (2.2-1) is that where the g c is omitted and the force (F =

mg) is given as lbm · ft/s2, called poundals. Then 1 lbm acted on by gravity will give a force of 32.174

poundals (lbm · ft/s2). Or if 1 g mass is used, the force (F = mg) is expressed in terms of dynes (g · cm/s2).
This is the centimeter–gram–second (cgs) systems of units.

Conversion factors for different units of force and of force per unit area (pressure) are given in Appendix
A.1. Note that always in the SI system, and usually in the cgs system, the term g c is not used.

EXAMPLE 2.2­1. Units and Dimensions of Force
Calculate the force exerted by 3 lb mass in terms of the following:

a.  Lb force (English units).
b.  Dynes (cgs units).

c.  Newtons (SI units).

S olu t ion: For part (a), using Eq. (2.2-1),

For part (b),

As an alternative method for part (b), from Appendix A.1,

To calculate newtons in part (c),

As an alternative method, using values from Appendix A.1,

2.2B. Pr e ssu r e  in a Flu id


Since Eq. (2.2-1) gives the force exerted by a mass under the influence of gravity, the force exerted by a
mass of fluid on a supporting area, or force/unit area (pressure), also follows from this equation. In Fig.
2.2-1 a stationary column of fluid of height h2 m and constant cross-sectional area A m2, where A = A0 =

A1 = A2, is shown. The pressure above the fluid is P0 N/m2; that is, this could be the pressure of the
atmosphere above the fluid. The fluid at any point, say h1, must support all the fluid above it. It can be
shown that the forces at any given point in a nonmoving or static fluid must be the same in all directions.
Also, for a fluid at rest, the force/unit area, or pressure, is the same at all points with the same elevation.
For example, at h1 m from the top, the pressure is the same at all points shown on the cross-sectional
area A1.

Figure 2.2-1. Pressure in a static fluid.

The use of Eq. (2.2-1) will be shown in calculating the pressure at different vertical points in Fig. 2.2-1.
The total mass of fluid for h2 m height and density ρ kg/m3 is

Equation 2.2-2

Substituting into Eq. (2.2-2), the total force F of the fluid on area A1 due to the fluid only is

Equation 2.2-3

The pressure P is defined as force/unit area:

Equation 2.2-4
This is the pressure on A2 due to the mass of the fluid above it. However, to get the total pressure P2 on
A2, the pressure P0 on the top of the fluid must be added:

Equation 2.2-5

Equation (2.2-5) is the fundamental equation for calculating the pressure in a fluid at any depth. To
calculate P1,

Equation 2.2-6

The pressure difference between points 2 and 1 is

Equation 2.2-7

Since it is the vertical height of a fluid that determines the pressure in a fluid, the shape of the vessel does
not affect the pressure. For example, in Fig. 2.2-2, the pressure P1 at the bottom of all three vessels is the
same and is equal to h1ρg + P0.

Figure 2.2-2. Pressure in vessels of various shapes.
EXAMPLE 2.2-2. Pressure in Storage Tank
A large storage tank contains oil having a density of 917 kg/m3 (0.917 g/cm3). The tank is 3.66
m (12.0 ft) tall and is vented (open) to the atmosphere of 1 atm abs at the top. The tank is filled
with oil to a depth of 3.05 m (10 ft) and also contains 0.61 m (2.0 ft) of water in the bottom of
the tank. Calculate the pressure in Pa and psia 3.05 m from the top of the tank and at the
bottom. Also calculate the gage pressure at the tank bottom.

S olu t ion: First a sketch is made of the tank, as shown in Fig. 2.2-3. The pressure P0 = 1 atm
abs = 14.696 psia (from Appendix A.1). Also,

Figure 2.2-3. Storage tank in Example 2.2-2.

From Eq. (2.2-6), using English and then SI units,

To calculate P2 at the bottom of the tank, ρwater  = 1.00 g/cm3 and
The gage pressure at the bottom is equal to the absolute pressure P2 minus 1 atm pressure:

2.2C . He ad  of a Flu id

Pressures are given in many different sets of units, such as psia, dyn/cm2, and newtons/m2, as given in
Appendix A.1. However, a common method of expressing pressures is in terms of head in m or feet of a
particular fluid. This height or head in m or feet of the given fluid will exert the same pressure as the
pressures it represents. Using Eq. (2.2-4), which relates pressure P and height h of a fluid, and solving for
h, which is the head in m,

Equation 2.2-8

EXAMPLE 2.2-3. Conversion of Pressure to Head of a
Fluid
Given the pressure of 1 standard atm as 101.325 kN/m2 (Appendix A.1), do as follows:

a.  Convert this pressure to head in m water at 4°C.

b.  Convert this pressure to head in m Hg at 0°C.

S olu t ion: For part (a), the density of water at 4°C in Appendix A.2 is 1.000 g/cm3. From A.1,
a density of 1.000 g/cm3 equals 1000 kg/m3. Substituting these values into Eq. (2.2-8),
For part (b), the density of Hg in Appendix A.1 is 13.5955 g/cm3. For equal pressures P from
different fluids, Eq. (2.2-8) can be rewritten as

Equation 2.2-9

Solving for hHg in Eq. (2.2-9) and substituting known values,

2.2D. De v ice s to M e asu r e  Pr e ssu r e  and  Pr e ssu r e  Diffe r e nce s

In chemical and other industrial processing plants, it is often important to measure and control the
pressure in a vessel or process and/or the liquid level in a vessel. Also, since many fluids are flowing in a
pipe or conduit, it is necessary to measure the rate at which the fluid is flowing. Many of these flow
meters depend upon devices for measuring a pressure or pressure difference. Some common devices are
considered in the following paragraphs.

1. S imp le U-t u b e ma nomet er

The U-tube manometer is shown in Fig. 2.2-4a. The pressure pa  N/m2 is exerted on one arm of the U tube
and pb on the other arm. Both pressures pa  and pb could be pressure taps from a fluid meter, or pa  could
be a pressure tap and pb the atmospheric pressure. The top of the manometer is filled with liquid B,

having a density of ρB kg/m3, and the bottom with a more dense fluid A, having a density of ρA kg/m3.
Liquid A is immiscible with B. To derive the relationship between pa  and pb, pa  is the pressure at point 1
and pb at point 5. The pressure at point 2 is

Equation 2.2-10

Figure 2.2-4. Manometers to measure pressure differences: (a) U tube; (b) two-fluid U tube.
where R is the reading of the manometer in m. The pressure at point 3 must be equal to that at 2 by the
principles of hydrostatics:

Equation 2.2-11

The pressure at point 3 also equals the following:

Equation 2.2-12

Equating Eq. (2.2-10) to (2.2-12) and solving,

Equation 2.2-13

Equation 2.2-14

The reader should note that the distance Z does not enter into the final result nor do the tube dimensions,
provided that pa  and pb are measured in the same horizontal plane.
EXAMPLE 2.2-4. Pressure Difference in a Manometer
A manometer, as shown in Fig. 2.2-4a, is being used to measure the head or pressure drop
across a flow meter. The heavier fluid is mercury, with a density of 13.6 g/cm3, and the top
fluid is water, with a density of 1.00 g/cm3. The reading on the manometer is R = 32.7 cm.
Calculate the pressure difference in N/m2 using SI units.

S olu t ion: Converting R to m,

Also converting ρA and ρB to kg/m3 and substituting into Eq. (2.2-14),

2. Tw o-flu id  U t u b e

In Fig. 2.2-4b a two-fluid U tube is shown, which is a sensitive device for measuring small heads or
pressure differences. Let A m2 be the cross-sectional area of each of the large reservoirs and a m2 be the
cross-sectional area of each of the tubes forming the U. Proceeding and making a pressure balance as for
the U tube,

Equation 2.2-15

where R0 is the reading when pa  = pb, R is the actual reading, ρA is the density of the heavier fluid, and
ρB is the density of the lighter fluid. Usually, a/A is made sufficiently small as to be negligible, and also
R0 is often adjusted to zero; then

Equation 2.2-16

If ρA and ρB are close to each other, the reading R is magnified.
EXAMPLE 2.2-5. Pressure Measurement in a Vessel
The U-tube manometer in Fig. 2.2-5a is used to measure the pressure pA in a vessel containing
a liquid with a density ρA. Derive the equation relating the pressure pA and the reading on the
manometer as shown.

Figure 2.2-5. Measurements of pressure in vessels: (a) measurement of pressure in a vessel, (b)
measurement of differential pressure.

S olu t ion: At point 2 the pressure is

Equation 2.2-17

At point 1 the pressure is

Equation 2.2-18

Equating p1 = p2 by the principles of hydrostatics and rearranging,

Equation 2.2-19

Another example of a U-tube manometer is shown in Fig. 2.2-5b. In this case the device is used to
measure the pressure difference between two vessels.

3. Bou r d on p r essu r e g a g e

Although manometers are used to measure pressures, the most common pressure-measuring device is
the mechanical Bourdon-tube pressure gage. A coiled hollow tube in the gage tends to straighten out
when subjected to internal pressure, and the degree of straightening depends on the pressure difference
between the inside and outside pressures. The tube is connected to a pointer on a calibrated dial.

4 . G r a v it y  sep a r a t or  for  t w o immiscib le liq u id s

In Fig. 2.2-6 a continuous gravity separator (decanter) is shown for the separation of two immiscible
liquids A (heavy liquid) and B (light liquid). The feed mixture of the two liquids enters at one end of the
separator vessel, and the liquids flow slowly to the other end and separate into two distinct layers. Each
liquid flows through a separate overflow line as shown. Assuming the frictional resistance to the flow of
the liquids is essentially negligible, the principles of fluid statics can be used to analyze the performance.

Figure 2.2-6. Continuous atmospheric gravity separator for immiscible liquids.

In Fig. 2.2-6, the depth of the layer of heavy liquid A is hA1 m and that of B is hB. The total depth hT = hA1
+ hB and is fixed by position of the overflow line for B. The heavy liquid A discharges through an overflow
leg hA2 m above the vessel bottom. The vessel and the overflow lines are vented to the atmosphere. A
hydrostatic balance gives

Equation 2.2-20

Substituting hB = hT − hA1 into Eq. (2.2-20) and solving for hA1,

Equation 2.2-21

This shows that the position of the interface or height hA1 depends on the ratio of the densities of the two
liquids and on the elevations hA2 and hT of the two overflow lines. Usually, the height hA2 is movable so
that the interface level can be adjusted.
                             
                                                 
                                             
                                               
     

2.3. GENERAL MOLECULAR TRANSPORT EQUATION FOR
MOMENTUM, HEAT, AND MASS TRANSFER

2.3A. G e ne r al M ole cu lar  Tr ansp or t Eq u ation and  G e ne r al Pr op e r ty Balance

1. Int r od u ct ion t o t r a nsp or t  p r ocesses

In molecular transport processes in general we are concerned with the transfer or movement of a given
property or entity by molecular movement through a system or medium which can be a fluid (gas or
liquid) or a solid. This property that is being transferred can be mass, thermal energy (heat), or
momentum. Each molecule of a system has a given quantity of the property mass, thermal energy, or
momentum associated with it. When a difference in concentration of the property exists for any of these
properties from one region to an adjacent region, a net transport of this property occurs. In dilute fluids
such as gases, where the molecules are relatively far apart, the rate of transport of the property should be
relatively fast, since few molecules are present to block the transport or interact. In dense fluids such as
liquids, the molecules are close together, and transport or diffusion proceeds more slowly. The molecules
in solids are even more closely packed than in liquids and molecular migration is even more restricted.

2. G ener a l molecu la r  t r a nsp or t  eq u a t ion

All three of the molecular transport processes of momentum, heat or thermal energy, and mass are
characterized in the elementary sense by the same general type of transport equation. First we start by
noting the following:

Equation 2.3-1

This states what is quite obvious—that we need a driving force to overcome a resistance in order to
transport a property. This is similar to Ohm's law in electricity, where the rate of flow of electricity is
proportional to the voltage drop (driving force) and inversely proportional to the resistance.

We can formalize Eq. (2.3-1) by writing an equation as follows for molecular transport or diffusion of a
property:

Equation 2.3-2
where   is defined as the flux of the property as amount of property being transferred per unit time per
unit cross-sectional area perpendicular to the z direction of flow in amount of property/s · m2, δ is a
proportionality constant called diffusivity in m2/s, Г is concentration of the property in amount of
property/m3, and z is the distance in the direction of flow in m.

If the process is at steady state, then the flux   is constant. Rearranging Eq. (2.3-2) and integrating,

Equation 2.3-3

Equation 2.3-4

A plot of the concentration Г versus z is shown in Fig. 2.3-1a and is a straight line. Since the flux is in the
direction 1 to 2 of decreasing concentration, the slope dГ/dz is negative, and the negative sign in Eq. (2.3-
2) gives a positive flux in the direction 1 to 2. In Section 2.3B the specialized equations for momentum,
heat, and mass transfer will be shown to be the same as Eq. (2.3-4) for the general property transfer.

Figure 2.3-1. Molecular transport of a property: (a) plot of concentration versus distance for steady state, (b)
unsteady-state general property balance.

EXAMPLE 2.3-1. Molecular Transport of a Property at
Steady State
A property is being transported by diffusion through a fluid at steady state. At a given point 1
the concentration is 1.37 × 10−2 amount of property/m3 and 0.72 × 10−2 at point 2 at a
distance z2 = 0.40 m. The diffusivity δ = 0.013 m2/s and the cross-sectional area is constant.

a.  Calculate the flux.

b.  Derive the equation for Г as a function of distance.

c.  Calculate Г at the midpoint of the path.

S olu t ion: For part (a), substituting into Eq. (2.3-4),

For part (b), integrating Eq. (2.3-2) between Г1 and Г and z1 and z and rearranging,

Equation 2.3-5

Equation 2.3-6

For part (c), using the midpoint z = 0.20 m and substituting into Eq. (2.3-6),

3. G ener a l p r op er t y  b a la nce for  u nst ea d y  st a t e

In calculating the rates of transport in a system using the molecular transport equation (2.3-2), it is
necessary to account for the amount of this property being transported in the entire system. This is done
by writing a general property balance or conservation equation for the property (momentum, thermal
energy, or mass) at unsteady state. We start by writing an equation for the z direction only, which
accounts for all the property entering by molecular transport, leaving, being generated, and
accumulating in a system shown in Fig. 2.3-1b, which is an element of volume Δz(1) m3 fixed in space.
Equation 2.3-7

The rate of input is   · 1 amount of property/s and the rate of output is   · 1, where the


cross-sectional area is 1.0 m2. The rate of generation of the property is R(Δz · 1), where R is rate of
generation of property/s · m3. The accumulation term is

Equation 2.3-8

Substituting the various terms into Eq. (2.3-7),

Equation 2.3-9

Dividing by Δz and letting Δz go to zero,

Equation 2.3-10

Substituting Eq. (2.3-2) for   into (2.3-10) and assuming that δ is constant,

Equation 2.3-11

For the case where no generation is present,

Equation 2.3-12
This final equation relates the concentration of the property Г to position z and time t.

Equations (2.3-11) and (2.3-12) are general equations for the conservation of momentum, thermal energy,
or mass and will be used in many sections of this text. The equations consider here only molecular
transport occurring and not other transport mechanisms such as convection and so on, which will be
considered when the specific conservation equations are derived in later sections of this text for
momentum, energy, and mass.

2.3B. Intr od u ction to M ole cu lar  Tr ansp or t

The kinetic theory of gases gives us a good physical interpretation of the motion of individual molecules
in fluids. Because of their kinetic energy the molecules are in rapid random movement, often colliding
with each other. Molecular transport or molecular diffusion of a property such as momentum, heat, or
mass occurs in a fluid because of these random movements of individual molecules. Each individual
molecule containing the property being transferred moves randomly in all directions, and there are fluxes
in all directions. Hence, if there is a concentration gradient of the property, there will be a net flux of the
property from high to low concentration. This occurs because equal numbers of molecules diffuse in each
direction between the high-concentration and low-concentration regions.

1. M oment u m t r a nsp or t  a nd  New t on's la w

When a fluid is flowing in the x direction parallel to a solid surface, a velocity gradient exists where the
velocity νx in the x direction decreases as we approach the surface in the z direction. The fluid has x-

directed momentum and its concentration is νxρ momentum/m3, where the momentum has units of kg ·

m/s. Hence, the units of νxρ are (kg · m/s)/m3. By random diffusion of molecules there is an exchange of
molecules in the z direction, an equal number moving in each direction (+z and −z directions) between
the faster-moving layer of molecules and the slower adjacent layer. Hence, the x-directed momentum has
been transferred in the z direction from the faster- to the slower-moving layer. The equation for this
transport of momentum is similar to Eq. (2.3-2) and is Newton's law of viscosity written as follows for
constant density ρ:

Equation 2.3-13

where τZX is flux of x-directed momentum in the z direction, (kg · m/s)/s · m2; v is μ/ρ, the momentum

diffusivity in m2/s; z is the distance of transport or diffusion in m; ρ is the density in kg/m3; and μ is the
viscosity in kg/m · s.

2. Hea t  t r a nsp or t  a nd  Fou r ier 's la w

Fourier's law for molecular transport of heat or heat conduction in a fluid or solid can be written as
follows for constant density ρ and heat capacity cp:

Equation 2.3-14

where qz/A is the heat flux in J/s · m2, α is the thermal diffusivity in m2/s, and ρcpT is the concentration

of heat or thermal energy in J/m3. When there is a temperature gradient in a fluid, equal numbers of
molecules diffuse in each direction between the hot and the colder region. In this way energy is
transferred in the z direction.

3. M a ss t r a nsp or t  a nd  Fick 's la w

Fick's law for molecular transport of mass in a fluid or solid for constant total concentration in the fluid
is

Equation 2.3-15

where   is the flux of A in kg mol A/s · m2, DAB is the molecular diffusivity of the molecule A in B in

m2/s, and cA is the concentration of A in kg mol A/m3. In a manner similar to momentum and heat
transport, when there is a concentration gradient in a fluid, equal numbers of molecules diffuse in each
direction between the high- and low-concentration regions and a net flux of mass occurs.

Hence, Eqs. (2.3-13), (2.3-14), and (2.3-15) for momentum, heat, and mass transfer are all similar to each
other and to the general molecular transport equation (2.3-2). All equations have a flux on the left-hand
side of each equation, a diffusivity in m2/s, and the derivative of the concentration with respect to
distance. All three of the molecular transport equations are mathematically identical. Thus, we state that
we have an analogy or similarity among them. It should be emphasized, however, that even though there
is a mathematical analogy, the actual physical mechanisms occurring may be totally different. For
example, in mass transfer two components are often being transported by relative motion through one
another. In heat transport in a solid, the molecules are relatively stationary and the transport is done
mainly by the electrons. Transport of momentum can occur by several types of mechanisms. More-
detailed considerations of each of the transport processes of momentum, energy, and mass are presented
in this and succeeding chapters.
                             
                                                 
                                             
                                               
     

2.4. VISCOSITY OF FLUIDS

2.4 A. Ne w ton's Law  and  Viscosity

When a fluid is flowing through a closed channel such as a pipe or between two flat plates, either of two
types of flow may occur, depending on the velocity of this fluid. At low velocities the fluid tends to flow
without lateral mixing, and adjacent layers slide past one another like playing cards. There are no cross
currents perpendicular to the direction of flow, nor eddies or swirls of fluid. This regime or type of flow is
called laminar flow. At higher velocities eddies form, which leads to lateral mixing. This is called
turbulent flow. The discussion in this section is limited to laminar flow.

A fluid can be distinguished from a solid in this discussion of viscosity by its behavior when subjected to
a stress (force per unit area) or applied force. An elastic solid deforms by an amount proportional to the
applied stress. However, a fluid, when subjected to a similar applied stress, will continue to deform, that
is, to flow at a velocity that increases with increasing stress. A fluid exhibits resistance to this stress.
Viscosity is that property of a fluid which gives rise to forces that resist the relative movement of adjacent
layers in the fluid. These viscous forces arise from forces existing between the molecules in the fluid and
are similar in character to the shear forces in solids.

The ideas above can be clarified by a more quantitative discussion of viscosity. In Fig. 2.4-1 a fluid is
contained between two infinite (very long and very wide) parallel plates. Suppose that the bottom plate is
moving parallel to the top plate and at a constant velocity Δνz m/s faster relative to the top plate because
of a steady force F newtons being applied. This force is called the viscous drag, and it arises from the
viscous forces in the fluid. The plates are Δy m apart. Each layer of liquid moves in the z direction. The
layer immediately adjacent to the bottom plate is carried along at the velocity of this plate. The layer just
above is at a slightly slower velocity, each layer moving at a slower velocity as we go up in the y direction.
This velocity profile is linear, with y direction as shown in Fig. 2.4-1. An analogy to a fluid is a deck of
playing cards, where, if the bottom card is moved, all the other cards above will slide to some extent.

Figure 2.4-1. Fluid shear between two parallel plates.

It has been found experimentally for many fluids that the force F in newtons is directly proportional to
the velocity Δνz in m/s and to the area A in m2 of the plate used, and inversely proportional to the
distance Δy in m. Or, as given by Newton's law of viscosity when the flow is laminar,
Equation 2.4-1

where μ is a proportionality constant called the viscosity of the fluid, in Pa · s or kg/m · s. If we let Δy
approach zero, then, using the definition of the derivative,

Equation 2.4-2

where τyz = F/A and is the shear stress or force per unit area in newtons/m2 (N/m2). In the cgs system, F
is in dynes, μ in g/cm · s, νz in cm/s, and y in cm. We can also write Eq. (2.2-2) as

Equation 2.4-3

where τyz is in units of lbf/ft 2.

The units of viscosity in the cgs system are g/cm · s, called poise or centipoise (cp). In the SI system,
viscosity is given in Pa · s (N · s/m2 or kg/m · s):

Other conversion factors for viscosity are given in Appendix A.1. Sometimes the viscosity is given as μ/p,
kinematic viscosity, in m2/s or cm2/s, where ρ is the density of the fluid.

EXAMPLE 2.4-1. Calculation of Shear Stress in a Liquid
Referring to Fig. 2.4-1, the distance between plates is Δy = 0.5 cm, Δνz = 10 cm/s, and the fluid
is ethyl alcohol at 273 K having a viscosity of 1.77 cp (0.0177 g/cm · s).

a.  Calculate the shear stress τyz and the velocity gradient or shear rate dνz/dy using cgs
units.

b.  Repeat, using lb force, s, and ft units (English units).

c.  Repeat, using SI units.
S olu t ion: We can substitute directly into Eq. (2.4-1) or we can integrate Eq. (2.4-2). Using
the latter method, rearranging Eq. (2.4-2), calling the bottom plate point 1, and integrating,

Equation 2.4-4

Equation 2.4-5

Substituting the known values,

Equation 2.4-6

To calculate the shear rate dνz/dy, since the velocity change is linear with y,

Equation 2.4-7

For part (b), using lb force units and the viscosity conversion factor from Appendix A.1,

Integrating Eq. (2.4-3),

Equation 2.4-8
Substituting known values into Eq. (2.4-8) and converting Δνz to ft/s and Δy to ft, τyz = 7.39 ×

10−4 lbf/ft 2. Also, dνz/dy = 20 s−1.

For part (c), Δy = 0.5/100 = 0.005 m, Δνz = 10/100 = 0.1 m/s, and μ = 1.77 × 10−3 kg/m · s =

1.77 × 10−3 Pa · s. Substituting into Eq. (2.4-5),

The shear rate will be the same at 20.0 s−1.

2.4 B. M om e ntu m  Tr ansfe r  in a Flu id

The shear stress τyz in Eqs. (2.4-1)–(2.4-3) can also be interpreted as a flux of z-directed momentum in
the y direction, which is the rate of flow of momentum per unit area. The units of momentum are mass
times velocity in kg · m/s. The shear stress can be written

Equation 2.4-9

This gives an amount of momentum transferred per second per unit area.

This can be shown by considering the interaction between two adjacent layers of a fluid in Fig. 2.4-1
which have different velocities, and hence different momentum, in the z direction. The random motions
of the molecules in the faster-moving layer send some of the molecules into the slower-moving layer,
where they collide with the slower-moving molecules and tend to speed them up or increase their
momentum in the z direction. Also, in the same fashion, molecules in the slower layer tend to retard
those in the faster layer. This exchange of molecules between layers produces a transfer or flux of z-
directed momentum from high-velocity to low-velocity layers. The negative sign in Eq. (2.4-2) indicates
that momentum is transferred down the gradient from high- to low-velocity regions. This is similar to
the transfer of heat from high- to low-temperature regions.

2.4 C . Viscositie s of Ne w tonian Flu id s

Fluids that follow Newton's law of viscosity, Eqs. (2.4-1)–(2.4-3), are called Newtonian fluids. For a
Newtonian fluid, there is a linear relation between the shear stress τyz and the velocity gradient dνz/dy
(rate of shear). This means that the viscosity μ is a constant and is independent of the rate of shear. For
non-Newtonian fluids, the relation between τyz and dνz/dy is not linear; that is, the viscosity μ does not
remain constant but is a function of shear rate. Certain liquids do not obey this simple law of Newton's.
These are primarily pastes, slurries, high polymers, and emulsions. The science of the flow and
deformation of fluids is often called rheology. A discussion of non-Newtonian fluids will not be given here
but will be included in Section 3.5.

The viscosity of gases, which are Newtonian fluids, increases with temperature and is approximately
independent of pressure up to a pressure of about 1000 kPa. At higher pressures, the viscosity of gases
increases with increase in pressure. For example, the viscosity of N2 gas at 298 K approximately doubles

in going from 100 kPa to about 5 × 104 kPa (R1). In liquids, the viscosity decreases with increasing
temperature. Since liquids are essentially incompressible, the viscosity is not affected by pressure.

In Table 2.4-1 some experimental viscosity data are given for some typical pure fluids at 101.32 kPa. The
viscosities for gases are the lowest and do not differ markedly from gas to gas, being about 5 × 10−6 to 3 ×
10−5 Pa · s. The viscosities for liquids are much greater. The value for water at 293 K is about 1 × 10−3 and
for glycerol 1.069 Pa · s. Hence, there are great differences between viscosities of liquids. More complete
tables of viscosities are given for water in Appendix A.2, for inorganic and organic liquids and gases in
Appendix A.3, and for biological and food liquids in Appendix A.4. Extensive data are available in other
references (P1, R1, W1, L1). Methods of estimating viscosities of gases and liquids when experimental
data are not available are summarized elsewhere (R1). These estimation methods for gases at pressures
below 100 kPa are reasonably accurate, with an error within about ±5%, but the methods for liquids are
often quite inaccurate.

Table 2.4-1. Viscosities of Some Gases and Liquids at 101.32 kPa Pressure

Gases Liquids

Viscosity Viscosity
(Pa · s) 103 (Pa · s) 103
or (kg/m · or (kg/m ·
Substance Temp., K s) 103 Ref. Substance Temp., K s) 103 Ref.

Air 293 0.01813 N1 Water 293 1.0019 S1

CO2 273 0.01370 R1   373 0.2821 S1

  373 0.01828 R1 Benzene 278 0.826 R1

CH4 293 0.01089 R1        

        Glycerol 293 1069 L1


SO2 373 0.01630 R1 Hg 293 1.55 R2

        Olive oil 303 84 E1
                             
                                                 
                                             
                                               
     

2.5. TYPES OF FLUID FLOW AND REYNOLDS NUMBER

2.5A. Intr od u ction and  Typ e s of Flu id  Flow

The principles of the statics of fluids, treated in Section 2.2, are almost an exact science. On the other
hand, the principles of the motions of fluids are quite complex. The basic relations describing the
motions of a fluid are the equations for the overall balances of mass, energy, and momentum, which will
be covered in the following sections.

These overall or macroscopic balances will be applied to a finite enclosure or control volume fixed in
space. We use the term “overall” because we wish to describe these balances from outside the enclosure.
The changes inside the enclosure are determined in terms of the properties of the streams entering and
leaving and the exchanges of energy between the enclosure and its surroundings.

When making overall balances on mass, energy, and momentum we are not interested in the details of
what occurs inside the enclosure. For example, in an overall balance, average inlet and outlet velocities
are considered. However, in a differential balance, the velocity distribution inside an enclosure can be
obtained by the use of Newton's law of viscosity.

In this section we first discuss the two types of fluid flow that can occur: laminar flow and turbulent flow.
Also, the Reynolds number used to characterize the regimes of flow is considered. Then in Sections 2.6,
2.7, and 2.8, the overall mass balance, energy balance, and momentum balance are covered together with
a number of applications. Finally, a discussion is given in Section 2.9 on the methods of making a shell
balance on an element to obtain the velocity distribution in the element and the pressure drop.

2.5B. Lam inar  and  Tu r b u le nt Flow

The type of flow occurring in a fluid in a channel is important in fluid dynamics problems. When fluids
move through a closed channel of any cross section, either of two distinct types of flow can be observed,
according to the conditions present. These two types of flow can commonly be seen in a flowing open
stream or river. When the velocity of flow is slow, the flow patterns are smooth. However, when the
velocity is quite high, an unstable pattern is observed, in which eddies or small packets of fluid particles
are present, moving in all directions and at all angles to the normal line of flow.

The first type of flow, at low velocities, where the layers of fluid seem to slide by one another without
eddies or swirls being present, is called laminar flow, and Newton's law of viscosity holds, as discussed
in Section 2.4A. The second type of flow, at higher velocities, where eddies are present giving the fluid a
fluctuating nature, is called turbulent flow.

The existence of laminar and turbulent flow is most easily visualized by the experiments of Reynolds. His
experiments are shown in Fig. 2.5-1. Water was allowed to flow at steady state through a transparent
pipe with the flow rate controlled by a valve at the end of the pipe. A fine, steady stream of dyed water
was introduced from a fine jet as shown and its flow pattern observed. At low rates of water flow, the dye
pattern was regular and formed a single line or stream similar to a thread, as shown in Fig. 2.5-1a. There
was no lateral mixing of the fluid, and it flowed in streamlines down the tube. By putting in additional
jets at other points in the pipe cross section, it was shown that there was no mixing in any parts of the
tube and the fluid flowed in straight parallel lines. This type of flow is called laminar or viscous flow.

Figure 2.5-1. Reynolds' experiment for different types of flow: (a) laminar flow; (b) turbulent flow.

As the velocity was increased, it was found that at a definite velocity the thread of dye became dispersed
and the pattern was very erratic, as shown in Fig. 2.5-1b. This type of flow is known as turbulent flow.
The velocity at which the flow changes is known as the critical velocity.

2.5C . R e ynold s Nu m b e r

Studies have shown that the transition from laminar to turbulent flow in tubes is not only a function of
velocity but also of density and viscosity of the fluid and the tube diameter. These variables are combined
into the Reynolds number, which is dimensionless:

Equation 2.5-1

where NRe is the Reynolds number, D the diameter in m, ρ the fluid density in kg/m3, μ the fluid
viscosity in Pa · s, and μ the average velocity of the fluid in m/s (where average velocity is defined as the
volumetric rate of flow divided by the cross-sectional area of the pipe). Units in the cgs system are D in
cm, ρ in g/cm3, μ in g/cm · s, and ν in cm/s. In the English system D is in ft, ρ in lbm/ft 3, μ in lbm/ft · s,
and ν in ft/s.

The instability of the flow that leads to disturbed or turbulent flow is determined by the ratio of the
kinetic or inertial forces to the viscous forces in the fluid stream. The inertial forces are proportional to
ρν2 and the viscous forces to μν/D, and the ratio ρν2/(μν/D) is the Reynolds number Dνρ/μ. Further
explanation and derivation of dimensionless numbers are given in Section 3.11.

For a straight circular pipe, when the value of the Reynolds number is less than 2100, the flow is always
laminar. When the value is over 4000, the flow will be turbulent, except in very special cases. In between
—called the transition region—the flow can be viscous or turbulent, depending upon the apparatus
details, which cannot be predicted.

EXAMPLE 2.5-1. Reynolds Number in a Pipe
Water at 303 K is flowing at the rate of 10 gal/min in a pipe having an inside diameter (ID) of
2.067 in. Calculate the Reynolds number using both English units and SI units.

S olu t ion: From Appendix A.1, 7.481 gal = 1 ft 3. The flow rate is calculated as

From Appendix A.2, for water at 303 K (30°C),

Substituting into Eq. (2.5-1).

Hence, the flow is turbulent. Using SI units,
                             
                                                 
                                             
                                               
     

2.6. OVERALL MASS BALANCE AND CONTINUITY EQUATION

2.6 A. Intr od u ction and  S im p le  M ass Balance s

In fluid dynamics fluids are in motion. Generally, they are moved from place to place by means of
mechanical devices such as pumps or blowers, by gravity head, or by pressure, and flow through systems
of piping and/or process equipment. The first step in the solution of flow problems is generally to apply
the principles of the conservation of mass to the whole system or to any part of the system. First, we will
consider an elementary balance on a simple geometry, and later we shall derive the general mass-balance
equation.

Simple mass or material balances were introduced in Section 1.5, where

Equation 1.5-1

Since, in fluid flow, we are usually working with rates of flow and usually at steady state, the rate of
accumulation is zero and we obtain

Equation 2.6-1

In Fig. 2.6-1 a simple flow system is shown, where fluid enters section 1 with an average velocity ν1 m/s

and density ρ1 kg/m3. The cross-sectional area is A1 m2. The fluid leaves section 2 with average velocity
ν2. The mass balance, Eq. (2.6-1), becomes

Equation 2.6-2

Figure 2.6-1. Mass balance on flow system.
where m = kg/s. Often, νρ is expressed as G = νρ, where G is mass velocity or mass flux in kg/s · m2. In
English units, ν is in ft/s, ρ in lbm/ft 3, A in ft 2, m in lbm/s, and G in lbm/s · ft 2.

EXAMPLE 2.6-1. Flow of Crude Oil and Mass Balance
A petroleum crude oil having a density of 892 kg/m3 is flowing through the piping
arrangement shown in Fig. 2.6-2 at a total rate of 1.388 × 10−3 m3/s entering pipe 1.

Figure 2.6-2. Piping arrangement for Example 2.6-1.

The flow divides equally in each of pipes 3. The steel pipes are schedule 40 pipe (see Appendix
A.5 for actual dimensions). Calculate the following, using SI units:

a.  The total mass flow rate m in pipe 1 and pipes 3.

b.  The average velocity v in 1 and 3.

c.  The mass velocity G in 1.

S olu t ion: From Appendix A.5, the dimensions of the pipes are as follows: 2-in. pipe: D1 (ID)
= 2.067 in.; cross-sectional area

-in. pipe: D3 (ID) = 1.610 in.; cross-sectional area

The total mass flow rate is the same through pipes 1 and 2 and is
Since the flow divides equally in each of pipes 3,

For part (b), using Eq. (2.6-2) and solving for v,

For part (c),

2.6 B. C ontr ol Volu m e  for  Balance s

The laws for the conservation of mass, energy, and momentum are all stated in terms of a system; these
laws give the interaction of a system with its surroundings. A system is defined as a collection of fluid of
fixed identity. However, in flow of fluids, individual particles are not easily identifiable. As a result,
attention is focused on a given space through which the fluid flows rather than on a given mass of fluid.
The method used, which is more convenient, is to select a control volume, which is a region fixed in space
through which the fluid flows.

In Fig. 2.6-3 the case of a fluid flowing through a conduit is shown. The control surface shown as a
dashed line is the surface surrounding the control volume. In most problems part of the control surface
will coincide with some boundary, such as the wall of the conduit. The remaining part of the control
surface is a hypothetical surface through which the fluid can flow, shown as point 1 and point 2 in Fig.
2.6-3. The control-volume representation is analogous to the open system of thermodynamics.

Figure 2.6-3. Control volume for flow through a conduit.
2.6 C . Ov e r all M ass-Balance  Eq u ation

In deriving the general equation for the overall balance of the property mass, the law of conservation of
mass may be stated as follows for a control volume where no mass is being generated.

Equation 2.6-3

We now consider the general control volume fixed in space and located in a fluid flow field, as shown in
Fig. 2.6-4. For a small element of area dA m2 on the control surface, the rate of mass efflux from this
element = (ρν)(dA cos α), where (dA cos α) is the area dA projected in a direction normal to the velocity
vector ν, α is the angle between the velocity vector ν and the outward-directed unit normal vector n to
dA, and ρ is the density in kg/m3. The quantity ρν has units of kg/s · m2 and is called a flux or mass
velocity G.

Figure 2.6-4. Flow through a differential area dA on a control surface.

From vector algebra we recognize that (ρν)(dA cos α) is the scalar or dot product ρ(v · n) dA. If we now
integrate this quantity over the entire control surface A, we have the net outflow of mass across the
control surface, or the net mass efflux in kg/s from the entire control volume V:

Equation 2.6-4

We should note that if mass is entering the control volume, that is, flowing inward across the control
surface, the next efflux of mass in Eq. (2.6-4) is negative, since α > 90° and cos α is negative. Hence,
there is a net influx of mass. If α < 90°, there is a net efflux of mass.

The rate of accumulation of mass within the control volume V can be expressed as follows:

Equation 2.6-5

where M is the mass of fluid in the volume in kg. Substituting Eqs. (2.6-4) and (2.6-5) into (2.6-3), we
obtain the general form of the overall mass balance:

Equation 2.6-6

The use of Eq. (2.6-6) can be shown for a common situation of steady-state one-dimensional flow, where
all the flow inward is normal to A1 and outward normal to A2, as shown in Fig. 2.6-3. When the velocity
ν2 leaving (Fig. 2.6-3) is normal to A2, the angle α2 between the normal to the control surface and the
direction of the velocity is 0°, and cos α2 = 1.0. Where ν1 is directed inward, α1 > π/2, and for the case in
Fig. 2.6-3, α1 is 180° (cos α1 = −1.0). Since α2 is 0° and α1 is 180°, using Eq. (2.6-4),

Equation 2.6-7

For steady state, dM/dt = 0 in Eq. (2.6-5), and Eq. (2.6-6) becomes

Equation 2.6-2
which is Eq. (2.6-2), derived earlier.

In Fig. 2.6-3 and Eqs. (2.6-3)–(2.6-7) we were not concerned with the composition of any of the streams.
These equations can easily be extended to represent an overall mass balance for component i in a
multicomponent system. For the case shown in Fig. 2.6-3, we combine Eqs. (2.6-5), (2.6-6), and (2.6-7),
add a generation term, and obtain

Equation 2.6-8

where mi2 is the mass flow rate of component i leaving the control volume and Ri is the rate of generation
of component i in the control volume in kg per unit time. (Diffusion fluxes are neglected here or are
assumed negligible.) In some cases, of course, Ri = 0 for no generation. Often it is more convenient to use
Eq. (2.6-8) written in molar units.

EXAMPLE 2.6-2. Overall Mass Balance in Stirred Tank
Initially, a tank holds 500 kg of salt solution containing 10% salt. At point (1) in the control
volume in Fig. 2.6-5, a stream enters at a constant flow rate of 10 kg/h containing 20% salt. A
stream leaves at point (2) at a constant rate of 5 kg/h. The tank is well stirred. Derive an
equation relating the weight fraction w A of the salt in the tank at any time t in hours.

Figure 2.6-5. Control volume for flow in a stirred tank for Example 2.6-2.

S olu t ion: First we make a total mass balance using Eq. (2.6-7) for the net total mass efflux
from the control volume:

Equation 2.6-9
From Eq. (2.6-5), where M is total kg of solution in control volume at time t,

Equation 2.6-5

Substituting Eqs. (2.6-5) and (2.6-9) into (2.6-6), and then integrating,

Equation 2.6-10

Equation 2.6-11

Equation (2.6-11) relates the total mass M in the tank at any time to t.

Next, making a component A salt balance, let w A = weight fraction of salt in tank at time t and
also the concentration in the stream m2 leaving at time t. Again using Eq. (2.6-7) but for a salt
balance,

Equation 2.6-12

Using Eq. (2.6-5) for a salt balance,

Equation 2.6-13

Substituting Eqs. (2.6-12) and (2.6-13) into (2.6-6),

Equation 2.6-14
Substituting the value for M from Eq. (2.6-11) into (2.6-14), separating variables, integrating,
and solving for w A,

Equation 2.6-15

Equation 2.6-16

Note that Eq. (2.6-8) for component i could have been used for the salt balance with Ri = 0 (no
generation).

2.6 D. Av e r age  Ve locity to Use  in Ov e r all M ass Balance

In solving the case in Eq. (2.6-7), we assumed a constant velocity ν1 at section 1 and constant ν2 at
section 2. If the velocity is not constant but varies across the surface area, an average or bulk velocity is
defined by

Equation 2.6-17

for a surface over which ν is normal to A and the density ρ is assumed constant.

EXAMPLE 2 6-3  Variation of Velocity Across Control


Surface and Average Velocity
For the case of incompressible flow (ρ is constant) through a circular pipe of radius R, the
velocity profile is parabolic for laminar flow as follows:

Equation 2.6-18

where νmax is the maximum velocity at the center where r = 0 and ν is the velocity at a radial
distance r from the center. Derive an expression for the average or bulk velocity νav  to use in
the overall mass-balance equation.

S olu t ion: The average velocity is represented by Eq. (2.6-17). In Cartesian coordinates dA is
dx dy. However, using polar coordinates, which are more appropriate for a pipe, dA = rdrdθ,
where θ is the angle in polar coordinates. Substituting Eq. (2.6-18), dA = rdrdθ, and A = πR2
into Eq. (2.6-17) and integrating,

Equation 2.6-19

Equation 2.6-20

In this discussion overall or macroscopic mass balances were made because we wish to describe these
balances from outside the enclosure. In this section on overall mass balances, some of the equations
presented may have seemed quite obvious. However, the purpose was to develop the methods which
should be helpful in the next sections. Overall balances will also be made on energy and momentum in
the next sections. These overall balances do not tell us the details of what happens inside. However, in
Section 2.9 a shell momentum balance will be made in order to obtain these details, which will give us
the velocity distribution and pressure drop. To further study these details of the processes occurring
inside the enclosure, differential balances rather than shell balances can be written; these are discussed
later in Sections 3.6–3.9 on differential equations of continuity and momentum transfer, Sections 5.6
and 5.7 on differential equations of energy change and boundary-layer flow, and Section 7.5B on
differential equations of continuity for a binary mixture.
                             
                                                 
                                             
                                               
     

2.7. OVERALL ENERGY BALANCE

2.7A. Intr od u ction

The second property to be considered in the overall balances on a control volume is energy. We shall
apply the principle of the conservation of energy to a control volume fixed in space in much the same
manner as the principle of conservation of mass was used to obtain the overall mass balance. The energy-
conservation equation will then be combined with the first law of thermodynamics to obtain the final
overall energy-balance equation.

We can write the first law of thermodynamics as

Equation 2.7-1

where E is the total energy per unit mass of fluid, Q is the heat absorbed per unit mass of fluid, and W is
the work of all kinds done per unit mass of fluid upon the surroundings. In the calculations, each term in
the equation must be expressed in the same type of units, such as J/kg (SI), btu/lbm, or ft · lbf/lbm
(English).

Since mass carries with it associated energy due to its position, motion, or physical state, we will find
that each of these types of energy will appear in the energy balance. In addition, we can also transport
energy across the boundary of the system without transferring mass.

2.7B. De r iv ation of Ov e r all Ene r gy-Balance  Eq u ation

The entity balance for a conserved quantity such as energy is similar to Eq. (2.6-3) and is as follows for a
control volume:

Equation 2.7-2

The energy E present within a system can be classified in three ways:

1.  Potential energy zg of a unit mass of fluid is the energy present because of the position of the mass
in a gravitational field g, where z is the relative height in meters from a reference plane. The units
for zg in the SI system are m · m/s2. Multiplying and dividing by kg mass, the units can be
expressed as (kg · m/s2) · (m/kg), or J/kg. In English units the potential energy is zg/g c in ft ·
lbf/lbm.
2.  Kinetic energy ν2/2 of a unit mass of fluid is the energy present because of translational or
rotational motion of the mass, where ν is the velocity in m/s relative to the boundary of the system
at a given point. Again, in the SI system the units of ν2/2 are J/kg. In the English system the
kinetic energy is ν2/2g c in ft · lbf/lbm.

3.  Internal energy U of a unit mass of a fluid is all of the other energy present, such as rotational and
vibrational energy in chemical bonds. Again the units are in J/kg or ft · lbf/lbm.

The total energy of the fluid per unit mass is then

Equation 2.7-3

The rate of accumulation of energy within the control volume V in Fig. 2.6-4 is

Equation 2.7-4

Next we consider the rate of energy input and output associated with mass in the control volume. The
mass added or removed from the system carries internal, kinetic, and potential energy. In addition,
energy is transferred when mass flows into and out of the control volume. Net work is done by the fluid as
it flows into and out of the control volume. This pressure–volume work per unit mass fluid is pV. The
contribution of shear work is usually neglected. The pV term and U term are combined using the
definition of enthalpy, H:

Equation 2.7-5

Hence, the total energy carried with a unit mass is (H + ν2/2 + zg).

For a small area dA on the control surface in Fig. 2.6-4, the rate of energy efflux is (H + ν2/2 + zg)(ρν)(dA
cos α), where (dA cos α) is the area dA projected in a direction normal to the velocity vector ν and α is the
angle between the velocity vector ν and the outward-directed unit normal vector n. We now integrate this
quantity over the entire control surface to obtain

Equation 2.7-6
Now we have accounted for all energy associated with mass in the system and moving across the
boundary in the entity balance, Eq. (2.7-2). Next we take into account heat and work energy which
transfers across the boundary and is not associated with mass. The term q is the heat transferred per unit
time across the boundary to the fluid because of a temperature gradient. Heat absorbed by the system is
positive by convention.

The work  , which is energy per unit time, can be divided into  , purely mechanical shaft work


identified with a rotating shaft crossing the control surface, and the pressure–volume work, which has
been included in the enthalpy term H in Eq. (2.7-6). By convention, work done by the fluid upon the
surroundings, that is, work out of the system, is positive.

To obtain the overall energy balance, we substitute Eqs. (2.7-4) and (2.7-6) into the entity balance Eq.

(2.7-2) and equate the resulting equation to q −  :

Equation 2.7-7

2.7C . Ov e r all Ene r gy Balance  for  S te ad y-S tate  Flow  S yste m

A common special case of the overall or macroscopic energy balance is that of a steady-state system with
one-dimensional flow across the boundaries, a single inlet, a single outlet, and negligible variation of
height z, density ρ, and enthalpy H across either inlet or outlet area. This is shown in Fig. 2.7-1. Setting
the accumulation term in Eq. (2.7-7) equal to zero and integrating,

Equation 2.7-8

Figure 2.7-1. Steady-state flow system for a fluid.
For steady state, m1 = ρ1ν1 av A1 = m2 = m. Dividing through by m so that the equation is on a unit mass
basis,

Equation 2.7-9

The term (ν3)av /(2νav ) can be replaced by  , where α is the kinetic-energy velocity correction factor

and is equal to  . The term α has been evaluated for various flows in pipes and is   for laminar


flow and close to 1.0 for turbulent flow. (See Section 2.7D.) Hence, Eq. (2.7-9) becomes

Equation 2.7-10

Some useful conversion factors from Appendix A.1 are as follows:
2.7D. K ine tic-Ene r gy Ve locity C or r e ction Factor  α

1. Int r od u ct ion

In obtaining Eq (2.7-8) it was necessary to integrate the kinetic-energy term,

Equation 2.7-11

which appeared in Eq. (2.7-7). To do this we first take ρ as a constant and cos α = 1.0. Then multiplying
the numerator and denominator by νav A, where νav  is the bulk or average velocity, and noting that m =
ρνav A, Eq. (2.7-11) becomes

Equation 2.7-12

Dividing through by m so that Eq. (2.7-12) is on a unit mass basis,

Equation 2.7-13

where α is defined as

Equation 2.7-14
and (ν3)av  is defined as follows:

Equation 2.7-15

The local velocity ν varies across the cross-sectional area of a pipe. To evaluate (ν3)av  and, hence, the
value of α, we must have an equation relating ν as a function of position in the cross-sectional area.

2. La mina r  flow

In order to determine the value of α for laminar flow, we first combine Eqs. (2.6-18) and (2.6-20) for
laminar flow to obtain ν as a function of position r:

Equation 2.7-16

Substituting Eq. (2.7-16) into (2.7-15) and noting that A = πR2 and dA = r dr dθ (see Example 2.6-3), Eq.
(2.7-15) becomes

Equation 2.7-17

Integrating Eq. (2.7-17) and rearranging,

Equation 2.7-18

Substituting Eq. (2.7-18) into (2.7-14),
Equation 2.7-19

Hence, for laminar flow the value of α to use in the kinetic-energy term of Eq. (2.7-10) is 0.50.

3. Tu r b u lent  flow

For turbulent flow a relationship is needed between ν and position. This can be approximated by the
following expression:

Equation 2.7-20

where r is the radial distance from the center. Eq. (2.7-20) is substituted into Eq. (2.7-15) and the
resultant integrated to obtain the value of (ν3)av . Next, Eq. (2.7-20) is substituted into Eq. (2.6-17) and

this equation integrated to obtain νav  and (νav )3. Combining the results for (ν3)av  and (νav )3 into Eq.


(2.7-14), the value of a α is 0.945. (See Problem 2.7-1 for solution.) The value of α for turbulent flow varies
from about 0.90 to 0.99. In most cases (except for precise work) the value of α is taken to be 1.0.

2.7E. Ap p lications of Ov e r all Ene r gy-Balance  Eq u ation

The total energy balance, Eq. (2.7-10), in the form given is not often used when appreciable enthalpy
changes occur or appreciable heat is added (or subtracted), since the kinetic- and potential-energy terms
are usually small and can be neglected. As a result, when appreciable heat is added or subtracted or large
enthalpy changes occur, the methods for doing heat balances described in Section 1.7 are generally used.
Examples will be given to illustrate this and other cases.

EXAMPLE 2.7-1. Energy Balance on Steam Boiler
Water enters a boiler at 18.33°C and 137.9 kPa through a pipe at an average velocity of 1.52
m/s. Exit steam at a height of 15.2 m above the liquid inlet leaves at 137.9 kPa, 148.9°C, and
9.14 m/s in the outlet line. At steady state, how much heat must be added per kg mass of
steam? The flow in the two pipes is turbulent.

S olu t ion: The process flow diagram is shown in Fig. 2.7-2. Rearranging Eq. (2.7-10) and
setting α = 1 for turbulent flow and WS = 0 (no external work),

Equation 2.7-21
Figure 2.7-2. Process flow diagram for Example 2.7-1.

To solve for the kinetic-energy terms,

Taking the datum height z1 at point 1, z2 = 15.2 m. Then,

From Appendix A.2, steam tables in SI units, H1 at 18.33°C = 76.97 kJ/kg, H2 of superheated
steam at 148.9°C = 2771.4 kJ/kg, and

Substituting these values into Eq. (2.7-21),

Hence, the kinetic-energy and potential-energy terms totaling 189.75 J/kg are negligible
compared to the enthalpy change of 2.694 × 106 J/kg. This 189.75 J/kg would raise the
temperature of liquid water about 0.0453°C, a negligible amount.

EXAMPLE 2.7-2. Energy Balance on a Flow System with a
Pump
Water at 85.0°C is being stored in a large, insulated tank at atmospheric pressure, as shown in
Fig. 2.7-3. It is being pumped at steady state from this tank at point 1 by a pump at the rate of
0.567 m3/min. The motor driving the pump supplies energy at the rate of 7.45 kW. The water
passes through a heat exchanger, where it gives up 1408 kW of heat. The cooled water is then
delivered to a second large open tank at point 2, which is 20 m above the first tank. Calculate
the final temperature of the water delivered to the second tank. Neglect any kinetic-energy
changes, since the initial and final velocities in the tanks are essentially zero.

Figure 2.7-3. Process flow diagram for energy balance for Example 2.7-2.

S olu t ion: From Appendix A.2, steam tables, H1 (85°C) = 355.90 × 103 J/kg and ρ1 =

1/0.0010325 = 968.5 kg/m3. Then, for steady state,

Also, z1 = 0 and z2 = 20 m. The work done by the fluid is WS, but in this case work is done on
the fluid and WS is negative:

The heat added to the fluid is also negative since it gives up heat and is

Setting   and substituting into Eq. (2.7-10),

Solving, H2 = 202.71 × 103 J/kg. From the steam tables this corresponds to t 2 = 48.41°C. Note
that in this example, WS and g(z2 − z1) are very small compared to Q.
EXAMPLE 2.7-3. Energy Balance in Flow Calorimeter
A flow calorimeter is being used to measure the enthalpy of steam. The calorimeter, which is a
horizontal insulated pipe, consists of an electric heater immersed in a fluid flowing at steady
state. Liquid water at 0°C at a rate of 0.3964 kg/min enters the calorimeter at point 1. The
liquid is vaporized completely by the heater, where 19.63 kW is added, and steam leaves point
2 at 250°C and 150 kPa absolute. Calculate the exit enthalpy H2 of the steam if the liquid
enthalpy at 0°C is set arbitrarily as 0. The kinetic-energy changes are small and can be
neglected. (It will be assumed that pressure has a negligible effect on the enthalpy of the
liquid.)

S olu t ion: For this case, WS = 0 since there is no shaft work between points 1 and 2. Also, 

 and g(z2 − z1) = 0. For steady state, m1 = m2 = 0.3964/60 =

6.607 × 10−3 kg/s. Since heat is added to the system,

The value of H1 = 0. Equation (2.7-10) becomes

The final equation for the calorimeter is

Equation 2.7-22

Substituting Q = 2971 kJ/kg and H1 = 0 into Eq. (2.7-22), H2 = 2971 kJ/kg at 250°C and 150
kPa, which is close to the value from the steam table of 2972.7 kJ/kg.

2.7F. Ov e r all M e chanical-Ene r gy Balance

A more useful type of energy balance for flowing fluids, especially liquids, is a modification of the total
energy balance to deal with mechanical energy. Engineers are often concerned with this special type of
energy, called mechanical energy, which includes the work term, kinetic energy, potential energy, and
the flow work part of the enthalpy term. Mechanical energy is a form of energy that is either work or a
form that can be directly converted into work. The other terms in the energy-balance equation (2.7-10),
heat terms and internal energy, do not permit simple conversion into work because of the second law of
thermodynamics and the efficiency of conversion, which depends on the temperatures. Mechanical-
energy terms have no such limitation and can be converted almost completely into work. Energy
converted to heat or internal energy is lost work or a loss in mechanical energy caused by frictional
resistance to flow.
It is convenient to write an energy balance in terms of this loss, Σ F, which is the sum of all frictional
losses per unit mass. For the case of steady-state flow, when a unit mass of fluid passes from inlet to
outlet, the batch work done by the fluid, W', is expressed as

Equation 2.7-23

This work W' differs from the W of Eq. (2.7-1), which also includes kinetic- and potential-energy effects.
Writing the first law of thermodynamics for this case, where ΔE becomes ΔU,

Equation 2.7-24

The equation defining enthalpy, Eq. (2.7-5), can be written as

Equation 2.7-25

Substituting Eq. (2.7-23) into (2.7-24) and then combining the resultant with Eq. (2.7-25), we obtain

Equation 2.7-26

Finally, we substitute Eq. (2.7-26) into (2.7-10) and 1/ρ for V, to obtain the overall mechanical-energy-
balance equation:

Equation 2.7-27

For English units the kinetic- and potential-energy terms of Eq. (2.7-27) are divided by g c.

The value of the integral in Eq. (2.7-27) depends on the equation of state of the fluid and the path of the
process. If the fluid is an incompressible liquid, the integral becomes (p2 − p1)/ρ and Eq. (2.7-27)
becomes

Equation 2.7-28

EXAMPLE 2.7-4. Mechanical-Energy Balance on Pumping
System
Water with a density of 998 kg/m3 is flowing at a steady mass flow rate through a uniform-
diameter pipe. The entrance pressure of the fluid is 68.9 kN/m2 abs in the pipe, which
connects to a pump that actually supplies 155.4 J/kg of fluid flowing in the pipe. The exit pipe
from the pump is the same diameter as the inlet pipe. The exit section of the pipe is 3.05 m
higher than the entrance, and the exit pressure is 137.8 kN/m2 abs. The Reynolds number in
the pipe is above 4000 in the system. Calculate the frictional loss Σ F in the pipe system.

S olu t ion: First a flow diagram of the system is drawn (Fig. 2.7-4), with 155.4 J/kg
mechanical energy added to the fluid. Hence, WS = −155.4, since the work done by the fluid is
positive.

Figure 2.7-4. Process flow diagram for Example 2.7-4.

Setting the datum height z1 = 0, z2 = 3.05 m. Since the pipe is of constant diameter, ν1 = ν2.
Also, for turbulent flow α = 1.0 and
Since the liquid can be considered incompressible, Eq. (2.7-28) is used:

Using Eq. (2.7-28) and solving for Σ F, the frictional losses,

Equation 2.7-29

Substituting the known values, and solving for the frictional losses,

EXAMPLE 2.7-5. Pump Horsepower in Flow System
A pump draws 69.1 gal/min of a liquid solution having a density of 114.8 lbm/ft 3 from an open
storage feed tank of large cross-sectional area through a 3.068-in.-ID suction line. The pump
discharges its flow through a 2.067-in.-ID line to an open overhead tank. The end of the
discharge line is 50 ft above the level of the liquid in the feed tank. The friction losses in the
piping system are Σ F = 10.0 ft-lb force/lb mass. What pressure must the pump develop and
what is the horsepower of the pump if its efficiency is 65% (η = 0.65)? The flow is turbulent.

S olu t ion: First, a flow diagram of the system is drawn (Fig. 2.7-5). Equation (2.7-28) will be
used. The term WS in Eq. (2.7-28) becomes

Equation 2.7-30

Figure 2.7-5. Process flow diagram for Example 2.7-5.
where −WS = mechanical energy actually delivered to the fluid by the pump or net mechanical
work, η = fractional efficiency, and Wp is the energy or shaft work delivered to the pump.

From Appendix A.5, the cross-sectional area of the 3.068-in. pipe is 0.05134 ft 2 and of the
2.067-in. pipe, 0.0233 ft 2. The flow rate is

ν1 = 0, since the tank is very large. Then   The pressure p1 = 1 atm and p2 = 1 atm.
Also, α = 1.0 since the flow is turbulent. Hence,

Using the datum of z1 = 0, we have

Using Eq. (2.4-28), solving for WS, and substituting the known values,
Using Eq. (2.7-30) and solving for Wp,

To calculate the pressure the pump must develop, Eq. (2.7-28) must be written over the pump
itself between points 3 and 4 as shown on the diagram:

Since the difference in level between z3 and z4 of the pump itself is negligible, it will be
neglected. Rewriting Eq. (2.7-28) between points 3 and 4 and substituting known values (Σ F
= 0, since this is for the piping system),

Equation 2.7-31
2.7G . Be r nou lli Eq u ation for  M e chanical-Ene r gy Balance

In the special case where no mechanical energy is added (WS = 0) and for no friction (Σ F= 0), then Eq.
(2.7-28) becomes the Bernoulli equation, Eq. (2.7-32), for turbulent flow, which is of sufficient
importance to deserve further discussion:

Equation 2.7-32

This equation covers many situations of practical importance and is often used in conjunction with the
mass-balance equation (2.6-2) for steady state:

Equation 2.6-2

Several examples of its use will be given.

EXAMPLE 2.7-6. Rate of Flow from Pressure
Measurements
A liquid with a constant density ρ kg/m3 is flowing at an unknown velocity ν1 m/s through a

horizontal pipe of cross-sectional area A1 m2 at a pressure p1 N/m2, and then it passes to a

section of the pipe in which the area is reduced gradually to A2 m2 and the pressure is p2.
Assuming no friction losses, calculate the velocities ν1 and ν2 if the pressure difference (p1 −
p2) is measured.

S olu t ion: In Fig. 2.7-6, the flow diagram is shown with pressure taps to measure p1 and p2.
From the mass-balance continuity equation (2.6-2), for constant ρ where ρ1 = ρ2 = ρ,

Equation 2.7-33

Figure 2.7-6. Process flow diagram for Example 2.7-6.

For the items in the Bernoulli equation (2.7-32), for a horizontal pipe,

Then Eq. (2.7-32) becomes, after substituting Eq. (2.7-33) for ν2,

Equation 2.7-34

Rearranging,

Equation 2.7-35

Equation 2.7-36
Performing the same derivation but in terms of ν2,

Equation 2.7-37

EXAMPLE 2.7-7. Rate of Flow from a Nozzle in a Tank
A nozzle of cross-sectional area A2 is discharging to the atmosphere and is located in the side
of a large tank, in which the open surface of the liquid in the tank is H m above the center line
of the nozzle. Calculate the velocity ν2 in the nozzle and the volumetric rate of discharge if no
friction losses are assumed.

S olu t ion: The process flow is shown in Fig. 2.7-7, with point 1 taken in the liquid at the
entrance to the nozzle and point 2 at the exit of the nozzle.

Figure 2.7-7. Nozzle flow diagram for Example 2.7-7.

Since A1 is very large compared to A2, ν1 ≅ 0. The pressure p1 is greater than 1 atm (101.3

kN/m2) by the head of fluid of H m. The pressure p2, which is at the nozzle exit, is at 1 atm.
Using point 2 as a datum, z2 = 0 and z1 = 0 m. Rearranging Eq. (2.7-32),

Equation 2.7-38
Substituting the known values,

Equation 2.7-39

Solving for ν2,

Equation 2.7-40

Since p1 − p3 = Hρg and p3 = p2 (both at 1 atm),

Equation 2.7-41

where H is the head of liquid with density ρ. Then Eq. (2.4-40) becomes

Equation 2.7-42

The volumetric flow rate is

Equation 2.7-43

To illustrate the fact that different points can be used in the balance, points 3 and 2 will be
used. Writing Eq. (2.7-32),

Equation 2.7-44
Equation 2.7-45
                             
                                                 
                                             
                                               
     

2.8. OVERALL MOMENTUM BALANCE

2.8A. De r iv ation of G e ne r al Eq u ation

A momentum balance can be written for the control volume shown in Fig. 2.6-3 which is somewhat
similar to the overall mass-balance equation. Momentum, in contrast to mass and energy, is a vector
quantity. The total linear momentum vector P of the total mass M of a moving fluid having a velocity of v
is

Equation 2.8-1

The term Mv is the momentum of this moving mass M enclosed at a particular instant in the control
volume shown in Fig. 2.6-4. The units of Mν are kg · m/s in the SI system.

Starting with Newton's second law, we will develop the integral momentum-balance equation for linear
momentum. Angular momentum will not be considered here. Newton's law may be stated: The time rate
of change of momentum of a system is equal to the summation of all forces acting on the system and
takes place in the direction of the net force:

Equation 2.8-2

where F is force. In the SI system F is in newtons (N) and 1 N = 1 kg · m/s2. Note that in the SI system g c
is not needed, but it is needed in the English system.

The equation for the conservation of momentum with respect to a control volume can be written as
follows:

Equation 2.8-3

This is in the same form as the general mass-balance equation (2.6-3), with the sum of the forces as the
generation rate term. Hence, momentum is not conserved, since it is generated by external forces on the
system. If external forces are absent, momentum is conserved.
Using the general control volume shown in Fig. 2.6-4, we shall evaluate the various terms in Eq. (2.8-3),
using methods very similar to the development of the general mass balance. For a small element of area
dA on the control surface, we write

Equation 2.8-4

Note that the rate of mass efflux is (ρν)(dA cos α). Also, note that (dA cos α) is the area dA projected in a
direction normal to the velocity vector ν, and α is the angle between the velocity vector ν and the
outward-directed-normal vector n. From vector algebra the product in Eq. (2.8-4) becomes

Equation 2.8-5

Integrating over the entire control surface A,

Equation 2.8-6

The net efflux represents the first two terms on the right-hand side of Eq. (2.8-3).

Similarly to Eq. (2.6-5), the rate of accumulation of linear momentum within the control volume V is

Equation 2.8-7

Substituting Equations (2.8-2), (2.8-6), and (2.8-7) into (2.8-3), the overall linear momentum balance
for a control volume becomes

Equation 2.8-8

We should note that Σ F in general may have a component in any direction, and that F is the force the
surroundings exert on the control-volume fluid. Since Eq. (2.8-8) is a vector equation, we may write the
component scalar equations for the x, y, and z directions:

Equation 2.8-9
Equation 2.8-10

Equation 2.8-11

The force term Σ Fx in Eq. (2.8-9) is composed of the sum of several forces. These are given as follows:

1.  Body force. The body force Fxg is the x-directed force caused by gravity acting on the total mass M
in the control volume. This force, Fxg, is Mg x. It is zero if the x direction is horizontal.

2.  Pressure force. The force Fxp is the x-directed force caused by the pressure forces acting on the
surface of the fluid system. When the control surface cuts through the fluid, the pressure is taken
to be directed inward and perpendicular to the surface. In some cases part of the control surface
may be a solid, and this wall is included inside the control surface. Then there is a contribution to
Fxp from the pressure on the outside of this wall, which typically is atmospheric pressure. If gage
pressure is used, the integral of the constant external pressure over the entire outer surface can be
automatically ignored.

3.  Friction force. When the fluid is flowing, an x-directed shear or friction force Fxs is present, which
is exerted on the fluid by a solid wall when the control surface cuts between the fluid and the solid
wall. In some or many cases, this frictional force may be negligible compared to the other forces
and is neglected.

4.  Solid surface force. In cases where the control surface cuts through a solid, there is present force
Rx, which is the x component of the resultant of the forces acting on the control volume at these
points. This occurs typically when the control volume includes a section of pipe and the fluid it
contains. This is the force exerted by the solid surface on the fluid.

The force terms of Eq. (2.8-9) can then be represented as

Equation 2.8-12
Similar equations can be written for the y and z directions. Then Eq. (2.8-9) becomes, for the x direction,

Equation 2.8-13

2.8B. Ov e r all M om e ntu m  Balance  in Flow  S yste m  in One  Dir e ction

A quite common application of the overall momentum-balance equation is the case of a section of a
conduit with its axis in the x direction. The fluid will be assumed to be flowing at steady state in the
control volume shown in Fig. 2.6-3 and in Fig. 2.8-1. Since ν = νx, Eq. (2.8-13) for the x direction becomes
as follows:

Equation 2.8-14

Figure 2.8-1. Flow through a horizontal nozzle in the x direction only.

Integrating, with cos α = ±1.0 and ρA = m/νav ,

Equation 2.8-15

where, if the velocity is not constant and varies across the surface area,
Equation 2.8-16

The ratio   is replaced by νxav /β where β, which is the momentum velocity correction

factor, has a value of 0.95 to 0.99 for turbulent flow and   for laminar flow. For most applications in

turbulent flow,   is replaced by νx av , the average bulk velocity. Note that the subscript x on


νx and Fx can be dropped, since νx = ν and Fx = F for one-directional flow.

The term Fxp, which is the force caused by the pressures acting on the surface of the control volume, is

Equation 2.8-17

The friction force will be neglected in Eq. (2.8-15), so Fxs = 0. The body force Fxg = 0 since gravity is

acting only in the y direction. Substituting Fxp from Eq. (2.8-17) into (2.8-15), replacing 
by ν/β (where νx av  = ν), setting β = 1.0, and solving for Rx in Eq. (2.8-15),

Equation 2.8-18

where Rx is the force exerted by the solid on the fluid. The force of the fluid on the solid (reaction force) is
the negative of this, or −Rx.

EXAMPLE 2.8-1. Momentum Velocity Correction Factor β
for Laminar Flow
The momentum velocity correction factor β is defined as follows for flow in one direction,
where the subscript x is dropped:

Equation 2.8-19
Equation 2.8-20

Determine β for laminar flow in a tube.

S olu t ion: Using Eq. (2.8-16),

Equation 2.8-21

Substituting Eq. (2.7-16) for laminar flow into Eq. (2.8-21) and noting that A = πR2 and dA = r
dr dθ, we obtain (see Example 2.6-3)

Equation 2.8-22

Integrating Eq. (2.8-22) and rearranging,

Equation 2.8-23

Substituting Eq. (2.8-23) into (2.8-20), β =  .

EXAMPLE 2.8-2. Momentum Balance for Horizontal Nozzle
Water is flowing at a rate of 0.03154 m3/s through a horizontal nozzle shown in Fig. 2.8-1 and
discharges to the atmosphere at point 2. The nozzle is attached at the upstream end at point 1
and frictional forces are considered negligible. The upstream ID is 0.0635 m and the
downstream 0.0286 m. Calculate the resultant force on the nozzle. The density of the water is
1000 kg/m3.

S olu t ion: First, the mass flow and average or bulk velocities at points 1 and 2 are calculated.
The area at point 1 is A1 = (π/4)(0.0635)2 = 3.167 × 10−3 m2 and A2 = (π/4)(0.0286)2 = 6.424

× 10−4 m2. Then,

The velocity at point 1 is ν1 = 0.03154/(3.167 × 10−3) = 9.96 m/s, and ν2 = 0.03154/(6.424 ×

10−4) = 49.1 m/s.

To evaluate the upstream pressure p1 we use the mechanical-energy-balance equation (2.7-28)
assuming no frictional losses and turbulent flow. (This can be checked by calculating the
Reynolds number.) This equation then becomes, for α = 1.0,

Equation 2.8-24

Setting p2 = 0 gage pressure, ρ = 1000 kg/m3, ν1 = 9.96 m/s, ν2 = 49.1 m/s, and solving for p1,

For the x direction, the momentum-balance equation (2.8-18) is used. Substituting the known
values and solving for Rx,

Since the force is negative, it is acting in the negative x direction, or to the left. This is the force
of the nozzle on the fluid. The force of the fluid on the solid is −Rx, or +2427 N.

2.8C . Ov e r all M om e ntu m  Balance  in Tw o Dir e ctions

Another application of the overall momentum balance is shown in Fig. 2.8-2 for a flow system with fluid
entering a conduit at point 1 inclined at an angle of α1 relative to the horizontal x direction and leaving a
conduit at point 2 at an angle α2. The fluid will be assumed to be flowing at steady state and the
frictional force Fxs will be neglected. Then Eq. (2.8-13) for the x direction becomes as follows for no
accumulation:

Equation 2.8-25

Figure 2.8-2. Overall momentum balance for flow system with fluid entering at point 1 and leaving at 2.

Integrating the surface (area) integral,

Equation 2.8-26

The term (ν2)av /νav  can again be replaced by νav /β, with β being set at 1.0. From Fig. 2.8-2, the term Fxp


is

Equation 2.8-27

Then Eq. (2.8-26) becomes as follows after solving for Rx:

Equation 2.8-28
The term Fxg = 0 in this case.

For Ry  the body force Fyg is in the negative y direction and Fyg = −mtg, where mt is the total mass fluid in
the control volume. Replacing cos α by sin α, the equation for the y direction becomes

Equation 2.8-29

EXAMPLE 2.8-3. Momentum Balance in a Pipe Bend
Fluid is flowing at steady state through a reducing pipe bend, as shown in Fig. 2.8-3.
Turbulent flow will be assumed with frictional forces negligible. The volumetric flow rate of the
liquid and the pressure p2 at point 2 are known, as are the pipe diameters at both ends. Derive
the equations to calculate the forces on the bend. Assume that the density ρ is constant.

Figure 2.8-3. Flow through a reducing bend in Example 2.8-3.

S olu t ion: The velocities ν1 and ν2 can be obtained from the volumetric flow rate and the
areas. Also, m = ρ1ν1A1 = ρ2ν2A2. As in Example 2.8-2, the mechanical-energy-balance
equation (2.8-24) is used to obtain the upstream pressure, p1. For the x direction, Eq. (2.8-28)
is used for the momentum balance. Since α1 = 0°, cos α1 = 1.0. Equation (2.8-28) becomes

Equation 2.8-30

For the y direction, the momentum-balance equation (2.8-29) is used, where sin α1 = 0:

Equation 2.8-31
where mt is total mass fluid in the pipe bend. The pressures at points 1 and 2 are gage
pressures since the atmospheric pressures acting on all surfaces cancel. The magnitude of the
resultant force of the bend acting on the control volume fluid is

Equation 2.8-32

The angle this makes with the vertical is θ = arctan(Rx/Ry ). Often the gravity force Fyg is small
compared to the other terms in Eq. (2.8-31) and is neglected.

EXAMPLE 2.8-4. Friction Loss in a Sudden Enlargement
A mechanical-energy loss occurs when a fluid flows from a small pipe to a large pipe through
an abrupt expansion, as shown in Fig. 2.8-4. Use the momentum balance and mechanical-
energy balance to obtain an expression for the loss for a liquid. (Hint: Assume that p0 = p1 and
ν0 = ν1. Make a mechanical-energy balance between points 0 and 2 and a momentum balance
between points 1 and 2. It will be assumed that p1 and p2 are uniform over the cross-sectional
area.)

Figure 2.8-4. Losses in expansion flow.

S olu t ion: The control volume is selected so that it does not include the pipe wall and Rx
drops out. The boundaries selected are points 1 and 2. The flow through plane 1 occurs only
through an area A0. The frictional drag force will be neglected, and all the loss is assumed to be
from eddies in this volume. Making a momentum balance between points 1 and 2 using Eq.
(2.8-18) and noting that p0 = p1, ν1 = ν0, and A1 = A2,

Equation 2.8-33

The mass flow rate is m = ν0ρA0 and ν2 = (A0/A2)ν0. Substituting these terms into Eq. (2.8-
33) and rearranging gives us

Equation 2.8-34

Applying the mechanical-energy-balance equation (2.7-28) to points 1 and 2,

Equation 2.8-35

Finally, combining Eqs. (2.8-34) and (2.8-35),

Equation 2.8-36

2.8D. Ov e r all M om e ntu m  Balance  for  Fr e e  Je t S tr iking a Fixe d  Vane

When a free jet impinges on a fixed vane as in Fig. 2.8-5, the overall momentum balance can be applied
to determine the force on the smooth vane. Since there are no changes in elevation or pressure before and
after impact, there is no loss in energy, and application of the Bernoulli equation shows that the
magnitude of the velocity is unchanged. Losses due to impact are neglected. The frictional resistance
between the jet and the smooth vane is also neglected. The velocity is assumed to be uniform throughout
the jet upstream and downstream. Since the jet is open to the atmosphere, the pressure is the same at all
ends of the vane.

Figure 2.8-5. Free jet impinging on a fixed vane: (a) smooth, curved vane, (b) smooth, flat vane.
In making a momentum balance for the control volume shown for the curved vane in Fig. 2.8-5a, Eq.
(2.8-28) is written as follows for steady state, where the pressure terms are zero, ν1 = ν2, A1 = A2, and m =
ν1A1ρ1 = ν2A2ν2:

Equation 2.8-37

Using Eq. (2.8-29) for the y direction and neglecting the body force,

Equation 2.8-38

Hence, Rx and Ry  are the force components of the vane on the control volume fluid. The force components
on the vane are −Rx and −Ry .

EXAMPLE 2.8-5. Force of Free Jet on a Curved, Fixed
Vane
A jet of water having a velocity of 30.5 m/s and a diameter of 2.54 × 10−2 m is deflected by a
smooth, curved vane as shown in Fig. 2.8-5a, where α2 = 60°. What is the force of the jet on

the vane? Assume that ρ = 1000 kg/m3.

S olu t ion: The cross-sectional area of the jet is A1 = π(2.54 × 10−2)2/4 = 5.067 × 10−4 m2.

Then, m = ν1A1ρ1 = 30.5 × 5.067 × 10−4 × 1000 = 15.45 kg/s. Substituting into Eqs. (2.8-37)
and (2.8-38),
The force on the vane is −Rx = +235.6 N and −Ry  = −408.1 N. The resultant force is calculated
using Eq. (2.8-32).

In Fig. 2.8-5b a free jet at velocity ν1 strikes a smooth, inclined flat plate and the flow divides into two
separate streams whose velocities are all equal (ν1 = ν2 = ν3) since there is no loss in energy. It is
convenient to make a momentum balance in the p direction parallel to the plate. No force is exerted on
the fluid by the flat plate in this direction; that is, there is no tangential force. Then, the initial
momentum component in the p direction must equal the final momentum component in this direction.
This means Σ F p = 0. Writing an equation similar to Eq. (2.8-26), where m1 is kg/s entering at 1 and m2
leaves at 2 and m3 at 3,

Equation 2.8-39

By the continuity equation,

Equation 2.8-40

Combining and solving,

Equation 2.8-41

The resultant force exerted by the plate on the fluid must be normal to it. This means the resultant force
is simply m1ν1 sin α2. Alternatively, the resultant force on the fluid can be calculated by determining Rx
and Ry  from Eqs. (2.8-28) and (2.8-29) and then using Eq. (2.8-32). The force on the bend is the opposite
of this.
                             
                                                 
                                             
                                               
     

2.9. SHELL MOMENTUM BALANCE AND VELOCITY PROFILE IN
LAMINAR FLOW

2.9 A. Intr od u ction

In Section 2.8 we analyzed momentum balances using an overall, macroscopic control volume. From this
we obtained the total or overall changes in momentum crossing the control surface. This overall
momentum balance did not tell us the details of what happens inside the control volume. In the present
section we analyze a small control volume and then shrink this control volume to differential size. In
doing this we make a shell momentum balance using the momentum-balance concepts of the preceding
section, and then, using the equation for the definition of viscosity, we obtain an expression for the
velocity profile inside the enclosure and the pressure drop. The equations are derived for flow systems of
simple geometry in laminar flow at steady state.

In many engineering problems a knowledge of the complete velocity profile is not needed, but a
knowledge of the maximum velocity, the average velocity, or the shear stress on a surface is needed. In
this section we show how to obtain these quantities from the velocity profiles.

2.9 B. S he ll M om e ntu m  Balance  Insid e  a Pip e

Engineers often deal with the flow of fluids inside a circular conduit or pipe. In Fig. 2.9-1 we have a
horizontal section of pipe in which an incompressible Newtonian fluid is flowing in one-dimensional,
steady-state, laminar flow. The flow is fully developed; that is, it is not influenced by entrance effects and
the velocity profile does not vary along the axis of flow in the x direction.

Figure 2.9-1. Contr ol volume for shell momentum balance on a fluid flowing in a circular tube.

The cylindrical control volume is a shell with an inside radius r, thickness Δr, and length Δx. At steady
state the conservation of momentum, Eq. (2.8-3), becomes as follows: sum of forces acting on control
volume = rate of momentum out − rate of momentum into volume. The pressure forces become, from Eq.
(2.8-17),

Equation 2.9-1

The shear force or drag force acting on the cylindrical surface at the radius r is the shear stress τrx times
the area 2πr Δx. However, this can also be considered as the rate of momentum flow into the cylindrical
surface of the shell as described by Eq. (2.4-9). Hence, the net rate of momentum efflux is the rate of
momentum out − rate of momentum in and is

Equation 2.9-2

The net convective momentum flux across the annular surface at x and x + Δx is zero, since the flow is
fully developed and the terms are independent of x. This is true since νx at x is equal to νx at x + Δx.

Equating Eq. (2.9-1) to (2.9-2) and rearranging,

Equation 2.9-3

In fully developed flow, the pressure gradient (Δp/Δx) is constant and becomes (Δp/L), where Δp is the
pressure drop for a pipe of length L. Letting Δr approach zero, we obtain

Equation 2.9-4

Separating variables and integrating,

Equation 2.9-5

The constant of integration C 1 must be zero if the momentum flux is not infinite at r = 0. Hence,

Equation 2.9-6
This means that the momentum flux varies linearly with the radius, as shown in Fig. 2.9-2, and the
maximum value occurs at r = R at the wall.

Figure 2.9-2. Velocity and momentum flux profiles for laminar flow in a pipe.

Substituting Newton's law of viscosity,

Equation 2.9-7

into Eq. (2.9-6), we obtain the following differential equation for the velocity:

Equation 2.9-8

Integrating using the boundary condition that at the wall, νx = 0 at r = R, we obtain the equation for the
velocity distribution:

Equation 2.9-9
This result shows us that the velocity distribution is parabolic, as shown in Fig. 2.9-2.

The average velocity νxav  for a cross section is found by summing up all the velocities over the cross
section and dividing by the cross-sectional area, as in Eq. (2.6-17). Following the procedure given in
Example 2.6-3, where dA = rdrdθ and A = πR2,

Equation 2.9-10

Combining Eqs. (2.9-9) and (2.9-10) and integrating,

Equation 2.9-11

where diameter D = 2R. Hence, Eq. (2.9-11), which is the Hagen–Poiseuille equation, relates the
pressure drop and average velocity for laminar flow in a horizontal pipe.

The maximum velocity for a pipe is found from Eq. (2.9-9) and occurs at r = 0:

Equation 2.9-12

Combining Eqs. (2.9-11) and (2.9-12), we find that

Equation 2.9-13

Also, dividing Eq. (2.9-9) by (2.9-11),

Equation 2.9-14

2.9 C . S he ll M om e ntu m  Balance  for  Falling Film


We now use an approach similar to that used for laminar flow inside a pipe for the case of flow of a fluid
as a film in laminar flow down a vertical surface. Falling films have been used to study various
phenomena in mass transfer, coatings on surfaces, and so on. The control volume for the falling film is
shown in Fig. 2.9-3a, where the shell of fluid considered is Δx thick and has a length of L in the vertical z
direction. This region is sufficiently far from the entrance and exit regions so that the flow is not affected
by these regions. This means the velocity νz(x) does not depend on position z.

Figure 2.9-3. Vertical laminar flow of a liquid film: (a) shell momentum balance for a control volume Δx thick;
(b) velocity and momentum flux profiles.

To start we set up a momentum balance in the z direction over a system Δx thick, bounded in the z
direction by the planes z = 0 and z = L, and extending a distance W in the y direction. First, we consider
the momentum flux due to molecular transport. The rate of momentum out − rate of momentum in is the
momentum flux at point x + Δx minus that at x times the area LW:

Equation 2.9-15

The net convective momentum flux is the rate of momentum entering the area ΔxW at z = L minus that
leaving at z = 0. This net efflux is equal to 0, since νz at z = 0 is equal to νz at z = L for each value of x:

Equation 2.9-16
The gravity force acting on the fluid is

Equation 2.9-17

Then, using Eq. (2.8-3) for the conservation of momentum at steady state,

Equation 2.9-18

Rearranging Eq. (2.9-18) and letting Δx → 0,

Equation 2.9-19

Equation 2.9-20

Integrating using the boundary conditions at x = 0, τxz = 0 at the free liquid surface and at x = x, τxz =
τxz,

Equation 2.9-21

This means the momentum-flux profile is linear, as shown in Fig. 2.9-3b, and the maximum value is at
the wall. For a Newtonian fluid using Newton's law of viscosity,

Equation 2.9-22

Combining Eqs. (2.9-21) and (2.9-22) we obtain the following differential equation for the velocity:

Equation 2.9-23
Separating variables and integrating gives

Equation 2.9-24

Using the boundary condition that νz = 0 at x = δ, C 1 = (ρg/2μ)δ2. Hence, the velocity-distribution
equation becomes

Equation 2.9-25

This means the velocity profile is parabolic, as shown in Fig. 2.9-3b. The maximum velocity occurs at x =
0 in Eq. (2.9-25) and is

Equation 2.9-26

The average velocity can be found by using Eq. (2.6-17):

Equation 2.9-27

Substituting Eq. (2.9-25) into (2.9-27) and integrating,

Equation 2.9-28
Combining Eqs. (2.9-26) and (2.9-28), we obtain  . The volumetric flow rate q is
obtained by multiplying the average velocity νzav  times the cross-sectional area δW:

Equation 2.9-29

Often in falling films, the mass rate of flow per unit width of wall Г in kg/s · m is defined as Г = ρδνzav
and a Reynolds number is defined as

Equation 2.9-30

Laminar flow occurs for NRe < 1200. Laminar flow with rippling present occurs above a NRe of 25.

EXAMPLE 2.9-1. Falling Film Velocity and Thickness
An oil is flowing down a vertical wall as a film 1.7 mm thick. The oil density is 820 kg/m3 and
the viscosity is 0.20 Pa · s. Calculate the mass flow rate per unit width of wall, Г, needed and
the Reynolds number. Also calculate the average velocity.

S olu t ion: The film thickness is δ = 0.0017 m. Substituting Eq. (2.9-28) into the definition of
Г,

Equation 2.9-31

Using Eq. (2.9-30),

Hence, the film is in laminar flow. Using Eq. (2.9-28),
                             
                                                 
                                             
                                               
     

2.10. DESIGN EQUATIONS FOR LAMINAR AND TURBULENT FLOW
IN PIPES

2.10A. Ve locity Pr ofile s in Pip e s

One of the most important applications of fluid flow is flow inside circular conduits, pipes, and tubes.
Appendix A.5 gives sizes of commercial standard steel pipe. Schedule 40 pipe in the different sizes is the
standard usually used. Schedule 80 has a thicker wall and will withstand about twice the pressure of
schedule 40 pipe. Both have the same outside diameter so that they will fit the same fittings. Pipes of
other metals have the same outside diameters as steel pipe to permit interchanging parts of a piping
system. Sizes of tubing are generally given by the outside diameter and wall thickness. Perry and Green
(P1) give detailed tables of various types of tubing and pipes.

When fluid is flowing in a circular pipe and the velocities are measured at different distances from the
pipe wall to the center of the pipe, it has been shown that in both laminar and turbulent flow, the fluid in
the center of the pipe is moving faster than the fluid near the walls. These measurements are made at a
reasonable distance from the entrance to the pipe. Figure 2.10-1 is a plot of the relative distance from the
center of the pipe versus the fraction of maximum velocity ν′/νmax, where ν′ is local velocity at the given
position and νmax the maximum velocity at the center of the pipe. For viscous or laminar flow, the
velocity profile is a true parabola, as derived in Eq. (2.9-9). The velocity at the wall is zero.

Figure 2.10-1. Velocity  distr ibution of a fluid across a pipe.

In many engineering applications the relation between the average velocity νav  in a pipe and the
maximum velocity νmax is useful, since in some cases only the νmax at the center point of the tube is
measured. Hence, from only one point measurement this relationship between νmax and νav  can be used
to determine νav . In Fig. 2.10-2 experimentally measured values of νav /νmax are plotted as a function of
the Reynolds numbers Dνav  ρ/μ and Dνmax ρ/μ.

Figure 2.10-2. Ratio ν av /ν max  as a function of Reynolds number for pipes.

The average velocity over the whole cross section of the pipe is precisely 0.5 times the maximum velocity
at the center as given by the shell momentum balance in Eq. (2.9-13) for laminar flow. On the other hand,
for turbulent flow, the curve is somewhat flattened in the center (see Fig. 2.10-1) and the average velocity
is about 0.8 times the maximum. This value of 0.8 varies slightly, depending upon the Reynolds
number, as shown in the correlation in Fig. 2.10-2. (Note: See Problem 2.6-3, where a value of 0.817 is

derived using the  -power law.)

2.10B. Pr e ssu r e  Dr op  and  Fr iction Loss in Lam inar  Flow

1. Pr essu r e d r op  a nd  loss d u e t o fr ict ion

When the fluid is in steady-state laminar flow in a pipe, then for a Newtonian fluid the shear stress is
given by Eq. (2.4-2), which is rewritten for change in radius dr rather than distance dy, as follows:

Equation 2.10-1

Using this relationship and making a shell momentum balance on the fluid over a cylindrical shell, the
Hagen–Poiseuille equation (2.9-11) for laminar flow of a liquid in circular tubes is obtained. This can be
written as

Equation 2.10-2

where p1 is upstream pressure at point 1, N/m2; p2 is pressure at point 2; ν is average velocity in tube,
m/s; D is inside diameter, m; and (L2 − L1) or ΔL is length of straight tube, m. For English units, the
right-hand side of Eq. (2.10-2) is divided by g c.

The quantity (p1 − p2)f or Δpf is the pressure loss due to skin friction. Then, for constant ρ, the friction
loss Ff is

Equation 2.10-3

This is the mechanical-energy loss due to skin friction for the pipe in N · m/kg of fluid and is part of the Σ
F term for frictional losses in the mechanical-energy-balance equation (2.7-28). This term (p1 − p2)f for
skin-friction loss is different from the (p1 − p2) term, owing to velocity head or potential head changes in
Eq. (2.7-28). That part of Σ F which arises from friction within the channel itself by laminar or turbulent
flow is discussed in Sections 2.10B and 2.10C. The part of friction loss due to fittings (valves, elbows,
etc.), bends, and the like, which sometimes constitute a large part of the friction, is discussed in Section
2.10F. Note that if Eq. (2.7-28) is applied to steady flow in a straight, horizontal tube, we obtain (p1 −
p2)/ρ = Σ F.

One of the uses of Eq. (2.10-2) is in the experimental measurement of the viscosity of a fluid by
measuring the pressure drop and volumetric flow rate through a tube of known length and diameter.
Slight corrections for kinetic energy and entrance effects are usually necessary in practice. Also, Eq. (2.10-
2) is often used in the metering of small liquid flows.

EXAMPLE 2.10-1. Metering of Small Liquid Flows
A small capillary with an inside diameter of 2.22 × 10−3 m and a length 0.317 m is being used
to continuously measure the flow rate of a liquid having a density of 875 kg/m3 and μ = 1.13 ×
10−3 Pa · s. The pressure-drop reading across the capillary during flow is 0.0655 m water
(density 996 kg/m3). What is the flow rate in m3/s if end-effect corrections are neglected?

S olu t ion: Assuming that the flow is laminar, Eq. (2.10-2) will be used. First, to convert the
height h of 0.0655 m water to a pressure drop using Eq. (2.2-4),
Substituting into Eq. (2.10-2) the values μ = 1.13 × 10−3 Pa · s, L2 − L1 = 0.317 m, D = 2.22 ×

10−3 m, and Δpf = 640 N/m2, and solving for ν,

Equation 2.10-2

The volumetric rate is then

Since it was assumed that laminar flow is occurring, the Reynolds number will be calculated to
check this:

Hence, the flow is laminar as assumed.

2. Use of fr ict ion fa ct or  for  fr ict ion loss in la mina r  flow

A common parameter used in laminar and especially in turbulent flow is the Fanning friction factor, f,
which is defined as the drag force per wetted surface unit area (shear stress τs at the surface) divided by

the product of density times velocity head, or  . The force is Δpf times the cross-sectional area πR2
and the wetted surface area is 2πR ΔL. Hence, the relation between the pressure drop due to friction and f
is as follows for laminar and turbulent flow:
Equation 2.10-4

Rearranging, this becomes

Equation 2.10-5

Equation 2.10-6

For laminar flow only, combining Eqs. (2.10-2) and (2.10-5),

Equation 2.10-7

Equations (2.10-2), (2.10-5), (2.10-6), and (2.10-7) for laminar flow hold up to a Reynolds number of
2100. Beyond that, at a NRe value above 2100, Eqs. (2.10-2) and (2.10-7) do not hold for turbulent flow.
For turbulent flow, Eqs. (2.10-5) and (2.10-6), however, are used extensively along with empirical
methods for predicting the friction factor f, as discussed in the next section.

EXAMPLE 2.10-2. Use of Friction Factor in Laminar Flow
Assume the same known conditions as in Example 2.10-1 except that the velocity of 0.275 m/s
is known and the pressure drop Δpf is to be predicted. Use the Fanning friction factor method.

S olu t ion: The Reynolds number is, as before,
From Eq. (2.10-7) the friction factor f is

Using Eq. (2.10-5) with ΔL = 0.317 m, ν = 0.275 m/s, D = 2.22 × 10−3 m, and ρ = 875 kg/m3,

This, of course, agrees with the value in Example 2.10-1.

When the fluid is a gas and not a liquid, the Hagen–Poiseuille equation (2.10-2) can be written as follows
for laminar flow:

Equation 2.10-8

where m = kg/s, M = molecular weight in kg/kg mol, T = absolute temperature in K, and R = 8314.3 N ·
m/kg mol · K. In English units, R = 1545.3 ft · lbf/lb mol · °R.

2.10C . Pr e ssu r e  Dr op  and  Fr iction Factor  in Tu r b u le nt Flow

In turbulent flow, as in laminar flow, the friction factor also depends on the Reynolds number. However,
it is not possible to predict theoretically the Fanning friction factor f for turbulent flow as was done for
laminar flow. The friction factor must be determined empirically (experimentally), and it not only
depends upon the Reynolds number but also on surface roughness of the pipe. In laminar flow the
roughness has essentially no effect.

Dimensional analysis also shows the dependence of the friction factor on these factors. In Sections 3.11
and 4.14, methods of obtaining the dimensionless numbers and their importance are discussed.

A large number of experimental data on friction factors for smooth pipe and pipes of varying degrees of
equivalent roughness have been obtained and the data correlated. For design purposes, to predict the
friction factor f and, hence, the frictional pressure drop for round pipe, the friction-factor chart in Fig.
2.10-3 can be used. It is a log–log plot of f versus NRe. This friction factor f is then used in Eqs. (2.10-5)
and (2.10-6) to predict the friction loss Δpf or Ff:

Equation 2.10-5
Equation 2.10-6

Figure 2.10-3. Friction factors for fluids inside pipes. [Based on L. F. Moody, Trans. A.S.M.E., 66, 671 (1944):
Mech. Eng. 69, 1005 (1947). With permission.]

For the region with a Reynolds number below 2100, the line is the same as Eq. (2.10-7). For a Reynolds
number above 4000 for turbulent flow, the lowest line in Fig. 2.10-3 represents the friction-factor line for
smooth pipes and tubes, such as glass tubes and drawn copper and brass tubes. The other lines, for
higher friction factors, represent lines for different relative roughness factors, ε/D, where D is the inside
pipe diameter in m and ε is a roughness parameter, which represents the average height in m of
roughness projections from the wall (M1). In Fig. 2.10-3, values for the equivalent roughness of new pipes
are given (M1). The most common pipe, commercial steel, has a roughness of ε = 4.6 × 10−5 m (1.5 ×
10−4 ft).

The reader should be cautioned about using friction factors f from other sources. The Fanning friction
factor f in Eq. (2.10-6) is the one used here. Others use a friction factor that may be four times larger.

EXAMPLE 2.10-3. Use of Friction Factor in Turbulent Flow
A liquid is flowing through a horizontal straight pipe at 4.57 m/s. The pipe used is commercial
steel, schedule 40, 2-in. nominal diameter. The viscosity of the liquid is 4.46 cp and the
density 801 kg/m3. Calculate the mechanical-energy friction loss Ff in J/kg for a 36.6-m
section of pipe.

S olu t ion: The following data are given: From Appendix A.5, D = 0.0525 m, ν = 4.57 m/s, ρ =
801 kg/m3, ΔL = 36.6 m, and

The Reynolds number is calculated as

Hence, the flow is turbulent. For commercial steel pipe from the table in Fig. 2.10-3, the
equivalent roughness is 4.6 × 10−5 m:

For a NRe of 4.310 × 104, the friction factor from Fig. 2.10-3 is f = 0.0060. Substituting into Eq.
(2.10-6), the friction loss is

In problems involving the friction loss Ff in pipes, Ff is usually the unknown, with the diameter D,
velocity ν, and pipe length ΔL known. Then a direct solution is possible, as in Example 2.10-3. However,
in some cases, the friction loss Ff is already set by the available head of liquid. Then if the volumetric flow
rate and pipe length are set, the unknown to be calculated is the diameter. This solution must be by trial
and error, since the velocity y appears in both NRe and f, which are unknown. In another case, with Ff
again being already set, the diameter and pipe length are specified. This solution is also by trial and
error, to calculate the velocity. Example 2.10-4 indicates the method to be used to calculate the pipe
diameter with Ff set. Others (M2) give a convenient chart to aid in these types of calculations.

EXAMPLE 2.10-4. Trial-and-Error Solution to Calculate
Pipe Diameter
Water at 4.4°C is to flow through a horizontal commercial steel pipe having a length of 305 m
at the rate of 150 gal/min. A head of water of 6.1 m is available to overcome the friction loss Ff.
Calculate the pipe diameter.

S olu t ion: From Appendix A.2, the density ρ = 1000 kg/m3 and the viscosity μ is

The solution is by trial and error since v appears in NRe and f. Assume that D = 0.089 m for
the first trial.

For commercial steel pipe and using Fig. 2.10-3, ε = 4.6 × 10−5 m. Then,

From Fig. 2.10-3 for NRe = 8.730 × 104 and ε/D = 0.00052, f = 0.0051. Substituting into Eq.
(2.10-6),

Solving for D, D = 0.0945 m. This does not agree with the assumed value of 0.089 m.

For the second trial, D will be assumed to be 0.0945 m.
From Fig. 2.10-3, f = 0.0052. It can be seen that f does not change much with NRe in the
turbulent region:

Solving, D = 0.0954 m or 3.75 in. Hence, the solution agrees closely with the assumed value of
D.

2.10D. Pr e ssu r e  Dr op  and  Fr iction Factor  in Flow  of G ase s

The equations and methods discussed in this section for turbulent flow in pipes hold for incompressible
liquids. They also hold for a gas if the density (or the pressure) changes by less than 10%. Then an
average density, ρav  in kg/m3, should be used and the errors involved will be less than the uncertainty
limits in the friction factor f. For gases, Eq. (2.10-5) can be rewritten as follows for laminar and turbulent
flow:

Equation 2.10-9

where ρav  is the density at pav  = (p1 + p2)/2. Also, the NRe used is DG/μ, where G is kg/m2 · s and is a


constant independent of the density and velocity variations for the gas. Equation (2.10-5) can also be
written for gases as

Equation 2.10-10
where R is 8314.3 J/kg mol · K or 1545.3 ft · lbf/lb mol · °R and M is molecular weight.

The derivation of Eqs. (2.10-9) and (2.10-10) applies only to cases with gases where the relative pressure
change is small enough that large changes in velocity do not occur. If the exit velocity becomes large, the
kinetic-energy term, which has been omitted, becomes important. For pressure changes above about
10%, compressible flow is occurring, and the reader should refer to Section 2.11. In adiabatic flow in a
uniform pipe, the velocity in the pipe cannot exceed the velocity of sound.

EXAMPLE 2.10-5. Flow of Gas in Line and Pressure Drop
Nitrogen gas at 25°C is flowing in a smooth tube having an inside diameter of 0.010 m at the
rate of 9.0 kg/s · m2. The tube is 200 m long and the flow can be assumed to be isothermal. The
pressure at the entrance to the tube is 2.0265 × 105 Pa. Calculate the outlet pressure.

S olu t ion: The viscosity of the gas from Appendix A.3 is μ = 1.77 × 10−5 Pa · s at T = 298.15 K.
Inlet gas pressure p1 = 2.0265 × 105 Pa, G = 9.0 kg/s · m2, D = 0.010 m, M = 28.02 kg/kg mol,
ΔL = 200 m, and R = 8314.3 J/kg mol · K. Assuming that Eq. (2.10-10) holds for this case and
that the pressure drop is less than 10%, the Reynolds number is

Hence, the flow is turbulent. Using Fig. 2.10-3, f = 0.0090 for a smooth tube.

Substituting into Eq. (2.10-10),

Solving, p2 = 1.895 × 105 Pa. Hence, Eq. (2.10-10) can be used, since the pressure drop is less
than 10%.

2.10E. Effe ct of He at Tr ansfe r  on Fr iction Factor

The friction factor f in Fig. 2.10-3 is given for isothermal flow, that is, no heat transfer. When a fluid is
being heated or cooled, the temperature gradient will cause a change in physical properties of the fluid,
especially the viscosity. For engineering practice the following method of Sieder and Tate (P1, S3) can be
used to predict the friction factor for nonisothermal flow for liquids and gases:

1.  Calculate the mean bulk temperature t a  as the average of the inlet and outlet bulk fluid


temperatures.
2.  Calculate the NRe using the viscosity μa  at t a  and use Fig. 2.10-3 to obtain f.

3.  Using the tube wall temperature t w , determine μw  at t w .

4.  Calculate ψ for the appropriate case:

Equation 2.10-11

Equation 2.10-12

Equation 2.10-13

Equation 2.10-14

5.  The final friction factor is obtained by dividing f from step 2 by ψ from step 4.

Hence, when the liquid is being heated, ψ is greater than 1.0 and the final f decreases. The reverse occurs
on cooling the liquid.

2.10F. Fr iction Losse s in Exp ansion, C ontr action, and  Pip e  Fittings

Skin-friction losses in flow through straight pipe are calculated by using the Fanning friction factor.
However, if the velocity of the fluid is changed in direction or magnitude, additional friction losses occur.
This results from additional turbulence which develops because of vortices and other factors. Methods for
estimating these losses are discussed below.

1. S u d d en enla r g ement  losses

If the cross section of a pipe enlarges very gradually, very little or no extra losses are incurred. If the
change is sudden, it results in additional losses due to eddies formed by the jet expanding in the enlarged
section. This friction loss can be calculated by the following for turbulent flow in both sections. The
following equation was derived in Example 2.8-4 as Eq. (2.8-3.6):

Equation 2.10-15

where hex is the friction loss in J/kg, Kex is the expansion-loss coefficent and equals (1 − A1/A2)2, ν1 is the
upstream velocity in the smaller area in m/s, ν2 is the downstream velocity, and α = 1.0. If the flow is

laminar in both sections, the factor α in the equation becomes  . For English units the right-hand side of
Eq. (2.10-15) is divided by g c. Also, h = ft · lbf/lbm.

2. S u d d en cont r a ct ion losses

When the cross section of the pipe is suddenly reduced, the stream cannot follow around the sharp
corner, and additional frictional losses due to eddies occur. For turbulent flow, this is given by

Equation 2.10-16

where hc is the friction loss, α = 1.0 for turbulent flow, ν2 is the average velocity in the smaller or
downstream section, and Kc is the contraction-loss coefficient (P1) and approximately equals 0.55 (1 −

A2/A1). For laminar flow, the same equation can be used with α =   (S2). For English units the right side
is divided by g c.

3. Losses in fit t ing s a nd  v a lv es

Pipe fittings and valves also disturb the normal flow lines in a pipe and cause additional friction losses.
In a short pipe with many fittings, the friction loss from these fittings could be greater than in the
straight pipe. The friction loss for fittings and valves is given by the following equation:

Equation 2.10-17

where Kf is the loss factor for the fitting or valve and ν1 is the average velocity in the pipe leading to the
fitting. Experimental values for Kf are given in Table 2.10-1 for turbulent flow (P1) and in Table 2.10-2 for
laminar flow.
Table 2.10-1. Friction Loss for Turbulent Flow Through Valves and Fittings

Frictional Loss, Equivalent
Frictional Loss, Numberof Length of Straight Pipe in
Type of Fitting or Valve Velocity Heads, K f Pipe Diameters, Le /D

Elbow, 45° 0.35 17
Elbow, 90° 0.75 35
Tee 1 50

Return bend 1.5 75

Coupling 0.04 2
Union 0.04 2

Gate valve    
  Wide open 0.17 9
  Half open 4.5 225

Globe valve    
  Wide open 6.0 300
  Half open 9.5 475

Angle valve, wide open 2.0 100

Check valve    

  Ball 70.0 3500

  Swing 2.0 100


Water meter, disk 7.0 350
Source: R. H. Perry and C. H. Chilton, Chemical Engineers' Handbook, 5th ed. New York: McGraw-
Hill Book Company, 1973. With permission.

Table 2.10-2. Friction Loss for Laminar Flow Through Valves and Fittings (K1)

  Frictional Loss, Number of Velocity Heads, K f Reynolds
Number

Type of Fitting or Valve 50 100 200 400 1000 Turbulent

Elbow, 90° 17 7 2.5 1.2 0.85 0.75


Tee 9 4.8 3.0 2.0 1.4 1.0
Globe valve 28 22 17 14 10 6.0

Check valve, swing 55 17 9 5.8 3.2 2.0

As an alternative method, some texts and references (B1) give data for losses in fittings as an equivalent
pipe length in pipe diameters. These data, also given in Table 2.10-1, are presented as Le/D, where Le is
the equivalent length of straight pipe in m having the same frictional loss as the fitting, and D is the
inside pipe diameter in m. The K values in Eqs. (2.10-15) and (2.10-16) can be converted to Le/D values
by multiplying the K by 50 (P1). The Le values for the fittings are simply added to the length of the
straight pipe to get the total length of equivalent straight pipe to use in Eq. (2.10-6).
4 . Fr ict iona l losses in mecha nica l-ener g y -b a la nce eq u a t ion

The frictional losses from the friction in the straight pipe (Fanning friction), enlargement losses,
contraction losses, and losses in fittings and valves are all incorporated in the ΣF term of Eq. (2.7-28) for
the mechanical-energy balance, so that

Equation 2.10-18

If all the velocities, ν, ν1, and ν2, are the same, then by factoring, Eq. (2.10-18) becomes, for this special
case,

Equation 2.10-19

The use of the mechanical-energy-balance equation (2.7-28) along with Eq. (2.10-18) will be shown in the
following examples.

EXAMPLE 2.10-6. Friction Losses and Mechanical-Energy
Balance
An elevated storage tank contains water at 82.2°C, as shown in Fig. 2.10-4. It is desired to
have a discharge rate at point 2 of 0.223 ft 3/s. What must be the height H in ft of the surface of
the water in the tank relative to the discharge point? The pipe used is commercial steel pipe,
schedule 40, and the lengths of the straight portions of pipe are shown.

Figure 2.10-4. Process flow diagram for Example 2.10-6.
S olu t ion: The mechanical-energy-balance equation (2.7-28) is written between points 1 and
2.

Equation 2.10-20

From Appendix A.2, for water, ρ = 0.970(62.43) = 60.52 lbm/ft 3 and μ = 0.347 cp =

0.347(6.7197 × 10−4) = 2.33 × 10−4 lbm/ft · s. The diameters of the pipes are

The velocities in the 4-in. and 2-in. pipe are

The Σ F term for frictional losses in the system includes the following: (1) contraction loss at
tank exit, (2) friction in the 4-in. straight pipe, (3) friction in 4-in. elbow, (4) contraction loss
from 4-in. to 2-in. pipe, (5) friction in the 2-in. straight pipe, and (6) friction in the two 2-in.
elbows. Calculations for the six items are as follows:

1.  Contraction loss at tank exit. From Eq. (2.10-16), for contraction from A1 to A3 cross-
sectional area, since A1 of the tank is very large compared to A3,

2.  Friction in the 4-in. pipe. The Reynolds number is
Hence, the flow is turbulent. From Fig. 2.10-3, ε = 4.6 × 10−5 m (1.5 × 10−4 ft).

Then, for NRe = 219 300, the Fanning friction factor f = 0.0047. Substituting into Eq.
(2.10-6) for ΔL = 20.0 ft of 4-in. pipe,

3.  Friction in 4-in. elbow. From Table 2.10-1, Kf = 0.75. Then, substituting into Eq. (2.10-
17),

4.  Contraction loss from 4- to 2-in. pipe. Using Eq. (2.10-16) again for contraction from
A3 to A4 cross-sectional area,

5.  Friction in the 2-in pipe. The Reynolds number is

The Fanning friction factor from Fig. 2.10-3 is f = 0.0048. The total length ΔL = 125 +
10 + 50 = 185 ft. Substituting into Eq. (2.10-6),
6.  Friction in the two 2-in. elbows. For a Kf = 0.75 and two elbows,

The total frictional loss Σ F is the sum of items (1) through (6):

Using as a datum level z2, z1 = H ft, z2 = 0. Since turbulent flow exists, α = 1.0. Also, ν1 = 0
and ν2 = ν4 = 9.57 ft/s. Since p1 and p2 are both at 1 atm abs pressure and ρ1 = ρ2,

Also, since no pump is used, WS = 0. Substituting these values into Eq. (2.10-20),

Solving, H(g/g c) = 33.77 ft · lbf/lbm (100.9 J/kg) and H is 33.77 ft (10.3 m) height of water
level above the discharge outlet.

EXAMPLE 2.10-7. Friction Losses with Pump in
Mechanical-Energy Balance
Water at 20°C is being pumped from a tank to an elevated tank at the rate of 5.0 × 10−3 m3/s.
All of the piping in Fig. 2.10-5 is 4-in. schedule 40 pipe. The pump has an efficiency of 65%.
Calculate the kW power needed for the pump.

Figure 2.10-5. Process flow diagram for Example 2.10-7.
S olu t ion: The mechanical-energy-balance equation (2.7-28) is written between points 1 and
2, with point 1 being the reference plane:

Equation 2.7-28

From Appendix A.2, for water, ρ = 998.2 kg/m3 and μ = 1.005 × 10−3 Pa · s. For 4-in. pipe,
from Appendix A.5, D = 0.1023 m and A = 8.219 × 10−3 m2. The velocity in the pipe is ν = 5.0
× 10−3/(8.219 × 10−3) = 0.6083 m/s. The Reynolds number is

Hence, the flow is turbulent.

The Σ F term for frictional losses includes the following: (1) contraction loss at tank exit, (2)
friction in the straight pipe, (3) friction in the two elbows, and (4) expansion loss at the tank
entrance.

1.  Contraction loss at tank exit. From Eq. (2.10-16), for contraction from a large A1 to a
small A2,

2.  Friction in the straight pipe. From Fig. 2.10-3, ε = 4.6 × 10−5 m and ε/D = 4.6 ×
10−5/0.1023 = 0.00045. Then for NRe = 6.181 × 104, f = 0.0051. Substituting into Eq.
(2.10-6) for ΔL = 5 + 50 + 15 + 100 = 170 m,

3.  Friction in the two elbows. From Table 2.10-1, Kf = 0.75. Then, substituting into Eq.
(2.10-7) for two elbows,

4.  Expansion loss at the tank entrance. Using Eq. (2.10-15),

The total frictional loss is Σ F:

Substituting into Eq. (2.7-28), where   and (p2 − p1) = 0,

Solving, WS = −153.93 J/kg. The mass flow rate is m = 5.0 × 10−3(998.2) = 4.991 kg/s. Using
Eq. (2.7-30),
2.10G . Fr iction Loss in Noncir cu lar  C ond u its

The friction loss in long, straight channels or conduits of noncircular cross section can be estimated by
using the same equations employed for circular pipes if the diameter in the Reynolds number and in the
friction-factor equation (2.10-6) is taken as the equivalent diameter. The equivalent diameter D is defined
as four times the hydraulic radius r H. The hydraulic radius is defined as the ratio of the cross-sectional
area of the channel to the wetted perimeter of the channel for turbulent flow only. Hence,

Equation 2.10-21

For example, for a circular tube,

For an annular space with outside diameter D1 and inside D2,

Equation 2.10-22

For a rectangular duct of sides a and b ft,

Equation 2.10-23

For open channels and partly filled ducts in turbulent flow, the equivalent diameter and Eq. (2.10-6) are
also used (P1). For a rectangle with depth of liquid y and width b,

Equation 2.10-24

For a wide, shallow stream of depth y,

Equation 2.10-25
For laminar flow in ducts running full and in open channels with various cross-sectional shapes other
than circular, equations are given elsewhere (P1).

2.10H. Entr ance  S e ction of a Pip e

If the velocity profile at the entrance region of a tube is flat, a certain length of tube is necessary for the
velocity profile to be fully established. This length for the establishment of fully developed flow is called
the transition length or entry length. This is shown in Fig. 2.10-6 for laminar flow. At the entrance the
velocity profile is flat; that is, the velocity is the same at all positions. As the fluid progresses down the
tube, the thickness of the boundary layers increases until finally they meet at the center of the pipe and
the parabolic velocity profile is fully established.

Figure 2.10-6. Velocity profiles near a pipe entrance for laminar flow.

The approximate entry length Le of a pipe of diameter D for a fully developed velocity profile to be formed
in laminar flow is (L2)

Equation 2.10-26

For turbulent flow, no relation is available to predict the entry length for a fully developed turbulent
velocity profile to form. As an approximation, the entry length is nearly independent of the Reynolds
number and is fully developed after 50 diameters downstream.

EXAMPLE 2.10-8. Entry Length for a Fluid in a Pipe
Water at 20°C is flowing through a tube of diameter 0.010 m at a velocity of 0.10 m/s.

a.  Calculate the entry length.

b.  Calculate the entry length for turbulent flow.

S olu t ion: For part (a), from Appendix A.2, ρ = 998.2 kg/m3, μ = 1.005 × 10−3 Pa · s. The
Reynolds number is
Using Eq. (2.10-26) for laminar flow,

Hence, Le = 0.571 m.

For turbulent flow in part (b), Le = 50(0.01) = 0.50 m.

The pressure drop or friction factor in the entry length is greater than in fully developed flow. For laminar
flow the friction factor is highest at the entrance (L2) and then decreases smoothly to the fully developed
flow value. For turbulent flow there will be some portion of the entrance over which the boundary layer is
laminar and the friction-factor profile is difficult to express. As an approximation, the friction factor for
the entry length can be taken as two to three times the value of the friction factor in fully developed flow.

2.10I. S e le ction of Pip e  S ize s

In large or complex process piping systems, the optimum size of pipe to use for a specific situation
depends upon the relative costs of capital investment, power, maintenance, and so on. Charts are
available for determining these optimum sizes (P1). However, for small installations, approximations are
usually sufficiently accurate. Representative values for ranges of velocity in pipes are shown in Table
2.10-3. For stainless-steel pipes, recent data (D1) show that the velocities in Table 2.10-3 for process lines
or pump discharge should be increased by 70%.

Table 2.10-3. Representative Ranges of Velocities in Steel Pipes

    Velocity
Type of Fluid Type of Flow ft/s m/s

Nonviscous liquid Inlet to pump 2–3 0.6–0.9


  Process line or pump 5.7 1.7
discharge
Viscous liquid Inlet to pump 0.2–0.8 0.06–0.25

  Process line or pump 3 0.9
discharge

Gas air Process line 53 16
Steam 100 psig Process line 38 11.6
                             
                                                 
                                             
                                               
     

2.11. COMPRESSIBLE FLOW OF GASES

2.11A. Intr od u ction and  Basic Eq u ation for  Flow  in Pip e s

When pressure changes in gases occur which are greater than about 10%, the friction-loss equations
(2.10-9) and (2.10-10) may be in error since compressible flow is occurring. Then the solution of the
energy balance is more complicated because of the variation of the density or specific volume with
changes in pressure. The field of compressible flow is very large and covers a very wide range of variation
in geometry, pressure, velocity, and temperature. In this section we restrict our discussion to isothermal
and adiabatic flow in uniform, straight pipes and do not cover flow in nozzles, which is discussed in
some detail in other references (M2, P1).

The general mechanical-energy-balance equation (2.7-27) can be used as a starting point. Assuming
turbulent flow, so that α = 1.0, and no shaft work, so that WS = 0, and writing the equation for a
differential length dL, Eq. (2.7-27) becomes

Equation 2.11-1

For a horizontal duct, dz = 0. Using only the wall shear frictional term for dF and writing Eq. (2.10-6) in
differential form,

Equation 2.11-2

where V = 1/ρ. Assuming steady-state flow and a uniform pipe diameter, G is constant and

Equation 2.11-3

Equation 2.11-4
Substituting Eqs. (2.11-3) and (2.11-4) into (2.11-2) and rearranging,

Equation 2.11-5

This is the basic differential equation that is to be integrated. To do this the relation between V and p
must be known so that the integral of dp/V can be evaluated. This integral depends upon the nature of
the flow, and two important conditions used are isothermal and adiabatic flow in pipes.

2.11B. Isothe r m al C om p r e ssib le  Flow

To integrate Eq. (2.11-5) for isothermal flow, an ideal gas will be assumed, where

Equation 2.11-6

Solving for V in Eq. (2.11-6), and substituting it into Eq. (2.11-5) and integrating, assuming f is constant,

Equation 2.11-7

Equation 2.11-8

Substituting p1/p2 for V2/V1 and rearranging,

Equation 2.11-9

where M = molecular weight in kg mass/kg mol, R = 8314.34 N · m/kg mol · K, and T = temperature K.
The quantity RT/M = pav /pav , where pav  = (p1 + p2)/2 and ρav  is the average density at T and pav . In
English units, R = 1545.3 ft · lbf/lb · mol · °R and the right-hand terms are divided by g c. Equation (2.11-
9) then becomes
Equation 2.11-10

The first term on the right in Eqs. (2.11-9) and (2.11-10) represents the frictional loss as given by Eqs.
(2.10-9) and (2.10-10). The last term in both equations is generally negligible in ducts of appreciable
length unless the pressure drop is very large.

EXAMPLE 2.11-1. Compressible Flow of a Gas in a Pipe
Line
Natural gas, which is essentially methane, is being pumped through a 1.016-m-ID pipeline for
a distance of 1.609 × 105 m (D1) at a rate of 2.077 kg mol/s. It can be assumed that the line is
isothermal at 288.8 K. The pressure p2 at the discharge end of the line is 170.3 × 103 Pa
absolute. Calculate the pressure p1 at the inlet of the line. The viscosity of methane at 288.8 K

is 1.04 × 10−5 Pa · s.

S olu t ion: D = 1.016 m, A = πD2/4 = π(1.016)2/4 = 0.8107 m2. Then,

From Fig. 2.10-3, ε = 4.6 × 105 m.

The friction factor f = 0.0027.

In order to solve for p1 in Eq. (2.11-9), trial and error must be used. Estimating p1 at 620.5 ×

103 Pa, R = 8314.34 N · m/kg mol · K, and ΔL = 1.609 × 105 m. Substituting into Eq. (2.11-9),
Now, P2 = 170.3 × 103 Pa. Substituting this into the above and solving for p1, p1 = 683.5 × 103
Pa. Substituting this new value of p1 into Eq. (2.11-9) again and solving for p1, the final result

is p1 = 683.5 × 103 Pa. Note that the last term in Eq. (2.11-9) in this case is almost negligible.

When the upstream pressure p1 remains constant, the mass flow rate G changes as the downstream
pressure p2 is varied. From Eq. (2.11-9), when p1 = p2, G = 0, and when p2 = 0, G = 0. This indicates that
at some intermediate value of p2, the flow G must be a maximum. This means that the flow is a
maximum when dG/dp2 = 0. Performing this differentiation on Eq. (2.11-9) for constant p1 and f and
solving for G,

Equation 2.11-11

Using Eqs. (2.11-3) and (2.11-6),

Equation 2.11-12

This is the equation for the velocity of sound in the fluid at the conditions for isothermal flow. Thus, for
isothermal compressible flow there is a maximum flow for a given upstream p1, and further reduction of
p2 will not give any further increase in flow. Further details as to the length of pipe and the pressure at
maximum flow conditions are discussed elsewhere (D1, M2, P1).

EXAMPLE 2.11-2. Maximum Flow for Compressible Flow
of a Gas
For the conditions of Example 2.11-1, calculate the maximum velocity that can be obtained
and the velocity of sound at these conditions. Compare with Example 2.11-1.

S olu t ion: Using Eq. (2.11-12) and the conditions in Example 2.11-1,

This is the maximum velocity obtainable if p2 is decreased. This is also the velocity of sound in
the fluid at the conditions for isothermal flow. To compare with Example 2.11-1, the actual
velocity at the exit pressure p2 is obtained by combining Eqs. (2.11-3) and (2.11-6) to give

Equation 2.11-13
2.11C . Ad iab atic C om p r e ssib le  Flow

When heat transfer through the wall of the pipe is negligible, the flow of gas in compressible flow in a
straight pipe of constant cross section is adiabatic. Equation (2.11-5) has been integrated for adiabatic
flow and details are given elsewhere (D1, M1, P1). Convenient charts for solving this case are also
available (P1). The results for adiabatic flow often deviate very little from isothermal flow, especially in
long lines. For very short pipes and relatively large pressure drops, the adiabatic flow rate is greater than
the isothermal, but the maximum possible difference is about 20% (D1). For pipes of length about 1000
diameters or longer, the difference is generally less than 5%. Equation (2.11-8) can also be used when the
temperature change over the conduit is small by using an arithmetic-average temperature.

Using the same procedures for finding maximum flow that were used in the isothermal case, maximum
flow occurs when the velocity at the downstream end of the pipe is the sonic velocity for adiabatic flow.
This is

Equation 2.11-14

where, γ = cp/cν , the ratio of heat capacities. For air, γ = 1.4. Hence, the maximum velocity for adiabatic
flow is about 20% greater than for isothermal flow. The rate of flow may not be limited by the flow
conditions in the pipe, in practice, but by the development of sonic velocity in a fitting or valve in the
pipe. Hence, care should be used in the selection of fittings in such pipes for compressible flow. Further
details as to the length of pipe and pressure at maximum flow conditions are given elsewhere (D1, M2,
P1).

A convenient parameter often used in compressible-flow equations is the Mach number, NMa , which is
defined as the ratio of ν, the speed of the fluid in the conduit, to νmax, the speed of sound in the fluid at
the actual flow conditions:

Equation 2.11-15

At a Mach number of 1.0, the flow is sonic. At a value less than 1.0, the flow is subsonic, and supersonic
at a number above 1.0.
                             
                                                 
                                             
                                               
     

PROBLEMS
2.2-1.
Pr essu r e in a  S p he r ica l Ta nk . Calculate the pressure in psia and kN/m2 at the bottom of a
spherical tank filled with oil having a diameter of 8.0 ft. The top of the tank is vented to the
atmosphere having a pressure of 14.72 psia. The density of the oil is 0.922 g/cm3.
A1: Ans.  17.92 lb /in. 2 (psia), 123.5 kN/m2
f
2.2-2.
Pr essu r e w it h Tw o Liq u id s, Hg  a nd  W a t er . An open test tube at 293 K is filled at the
bottom with 12.1 cm of Hg, and 5.6 cm of water is placed above the Hg. Calculate the pressure at
the bottom of the test tube if the atmospheric pressure is 756 mm Hg. Use a density of 13.55
g/cm3 for Hg and 0.998 g/cm3 for water. Give the answer in terms of dyn/cm2, psia, and
kN/m2. See Appendix A.1 for conversion factors.
A2: Ans.  1.175 × 106 dyn/cm2, 17.0 psia, 2.3 psig, 117.5 kN/m2
2.2-3.
Hea d  of a  Flu id  of Jet  Fu el a nd  Pr essu r e. The pressure at the top of a tank of jet fuel is
180.6 kN/m2. The depth of liquid in the tank is 6.4 m. The density of the fuel is 825 kg/m3.
Calculate the head of the liquid in m that corresponds to the absolute pressure at the bottom of
the tank.
2.2-4 .
M ea su r ement  of Pr essu r e. An open U-tube manometer similar to Fig. 2.2-4a is being used to
measure the absolute pressure pa  in a vessel containing air. The pressure pb is atmospheric
pressure, which is 754 mm Hg. The liquid in the manometer is water having a density of 1000
kg/m3. Assume that the density ρB is 1.30 kg/m3 and that the distance Z is very small. The
reading R is 0.415 m. Calculate pa  in psia and kPa.
A4 :Ans. pa  = 15.17 psia, 104.6 kPa
2.2-5.
M ea su r ement  of S ma ll Pr essu r e Differ ences. The two-fluid U-tube manometer is being
used to measure the difference in pressure at two points in a line containing air at 1 atm abs
pressure. The value of R0 = 0 for equal pressures. The lighter fluid is a hydrocarbon with a

density of 812 kg/m3 and the heavier water has a density of 998 kg/m3. The inside diameters of
the U tube and reservoir are 3.2 mm and 54.2 mm, respectively. The reading R of the manometer
is 117.2 mm. Calculate the pressure difference in mm Hg and pascal.
2.2-6 .
Pr essu r e in a  S ea  La b . A sea lab 5.0 m high is to be designed to withstand submersion to 150
m, measured from sea level to the top of the sea lab. Calculate the pressure on top of the sea lab
and also the pressure variation on the side of the container measured as the distance x in m from
the top of the sea lab downward. The density of seawater is 1020 kg/m3.
A6 : Ans.  p = 10.00(150 + × ) kN/m2
2.2-7.
M ea su r ement  of Pr essu r e Differ ence in Vessels. In Fig. 2.2-5b the differential manometer
is used to measure the pressure difference between two vessels. Derive the equation for the
pressure difference pA − pB in terms of the liquid heights and densities.
2.2-8.
Desig n of S et t ler  a nd  S ep a r a t or  for  Immiscib le Liq u id s. A vertical cylindrical settler–
separator is to be designed for separating a mixture flowing at 20.0 m3/h and containing equal
volumes of a light petroleum liquid (ρB = 875 kg/m3) and a dilute solution of wash water (ρA =

1050 kg/m3). Laboratory experiments indicate a settling time of 15 min is needed to adequately
separate the two phases. For design purposes use a 25-min settling time and calculate the size of
the vessel needed, the liquid levels of the light and heavy liquids in the vessel, and the height hA2
of the heavy-liquid overflow. Assume that the ends of the vessel are approximately flat, that the
vessel diameter equals its height, and that one-third of the volume is vapor space vented to the
atmosphere. Use the nomenclature given in Fig. 2.2-6.
A8:Ans. hA2 = 1.537 m
2.3-1.
M olecu la r  Tr a nsp or t  of a  Pr op er t y  w it h a  Va r ia b le Diffu siv it y . A property is being
transported through a fluid at steady state through a constant cross-sectional area. At point 1
the concentration Г1 is 2.78 × 10−2 amount of property/m3 and 1.50 × 10−2 at point 2 at a
distance of 2.0 m away. The diffusivity depends on concentration Г as follows:

a.  Derive the integrated equation for the flux in terms of Г1 and Г2. Then calculate the flux.

b.  Calculate Г at z = 1.0 m and plot Г versus z for the three points.

A9 :  

Ans.
2.3-2.
Int eg r a t ion of G ener a l-Pr op er t y  Eq u a t ion for  S t ea d y  S t a t e. Integrate the general-
property equation (2.3-11) for steady state and no generation between the points Г1 at z1 and Г2
at z2. The final equation should relate Г to z.
A10:Ans. Г = (Г2 − Г1)(z − z1)/(z2 − z1) + Г1
2.4 -1.
S hea r  S t r ess in S oy b ea n Oil. Using Fig. 2.4-1, the distance between the two parallel plates is
0.00914 m, and the lower plate is being pulled at a relative velocity of 0.366 m/s greater than
the top plate. The fluid used is soybean oil with viscosity 4 × 10−2 Pa · s at 303 K (Appendix
A.4).

a.  Calculate the shear stress τ and the shear rate using lb force, ft, and s units.

b.  Repeat, using SI untis.

c.  If glycerol at 293 K having a viscosity of 1.069 kg/m ·s is used instead of soybean oil, what
relative velocity in m/s is needed using the same distance between plates so that the same
shear stress is obtained as in part (a)? Also, what is the new shear rate?

A11: Ans.  (a) Shear stress = 3.34 × 10−2 lb /ft 2, shear rate = 40.0 s−1; (b) 1.60 N/m2; (c) relative


f
velocity = 0.01369 m/s, shear rate = 1.50 s−1
2.4 .-2
S hea r  S t r ess a nd  S hea r  R a t e in Flu id s. Using Fig. 2.4-1, the lower plate is being pulled at
a relative velocity of 0.40 m/s greater than the top plate. The fluid used is water at 24°C.

a.  How far apart should the two plates be placed so that the shear stress τ is 0.30 N/m2?
Also, calculate the shear rate.

b.  If oil with a viscosity of 2.0 × 10−2 Pa · s is used instead at the same plate spacing and
velocity as in part (a), what are the shear stress and the shear rate?

2.5-1.
R ey nold s Nu mb er  for  M ilk  Flow . Whole milk at 293 K having a density of 1030 kg/m3 and
viscosity of 2.12 cp is flowing at the rate of 0.605 kg/s in a glass pipe having a diameter of 63.5
mm.

a.  Calculate the Reynolds number. Is this turbulent flow?

b.  Calculate the flow rate needed in m3/s for a Reynolds number of 2100 and velocity in m/s.

A13:Ans. (a) NRe = 5723, turbulent flow
2.5-2.
Pip e Dia met er  a nd  R ey nold s Nu mb er . An oil is being pumped inside a 10.0-mm-diameter
pipe at a Reynolds number of 2100. The oil density is 855 kg/m3 and the viscosity is 2.1 × 10−2
Pa · s.

a.  What is the velocity in the pipe?

b.  It is desired to maintain the same Reynolds number of 2100 and the same velocity as in
part (a) using a second fluid with a density of 925 kg/m3 and a viscosity of 1.5 × 10−2 Pa ·
s. What pipe diameter should be used?

2.6 -1.
Av er a g e Velocit y  for  M a ss Ba la nce in Flow  Dow n Ver t ica l Pla t e. For a layer of liquid
flowing in laminar flow in the z direction down a vertical plate or surface, the velocity profile is

where δ is the thickness of the layer, × is the distance from the free surface of the liquid toward
the plate, and νz is the velocity at a distance × from the free surface.

a.  What is the maximum velocity νz max?

b.  Derive the expression for the average velocity νz av  and also relate it to νz max.

A15:
 

Ans.
2.6 -2.
Flow  of Liq u id  in a  Pip e a nd  M a ss Ba la nce. A hydrocarbon liquid enters a simple flow
system shown in Fig. 2.6-1 at an average velocity of 1.282 m/s, where A1 = 4.33 × 10−3 m2 and ρ1

= 902 kg/m3. The liquid is heated in the process and the exit density is 875 kg/m3. The cross-
sectional area at point 2 is 5.26 × 10−3 m2. The process is steady state.

a.  Calculate the mass flow rate m at the entrance and exit.

b.  Calculate the average velocity ν in 2 and the mass velocity G in 1.

A16 : Ans.  (a) m  = m  = 5.007 kg/s, (b) G  = 1156 kg/s · m2


1 2 1
2.6 -3.
Av er a g e Velocit y  for  M a ss Ba la nce in Tu r b u lent  Flow . For turbulent flow in a smooth,
circular tube with a radius R, the velocity profile varies according to the following expression at a
Reynolds number of about 105:

where r is the radial distance from the center and νmax the maximum velocity at the center.
Derive the equation relating the average velocity (bulk velocity) νav  to νmax for an incompressible
fluid. (Hint: The integration can be simplified by substituting z for R − r.)
A17:  

Ans.
2.6 -4 .
Bu lk  Velocit y  for  Flow  Bet w een Pa r a llel Pla t es. A fluid flowing in laminar flow in the x
direction between two parallel plates has a velocity profile given by the following:

where 2y 0 is the distance between the plates, y is the distance from the center line, and νx is the
velocity in the × direction at position y. Derive an equation relating νx av  (bulk or average
velocity) to νx max.
A18:  

Ans.
2.6 -5.
Ov er a ll M a ss Ba la nce for  Dilu t ion Pr ocess. A well-stirred storage vessel contains 10 000
kg of solution of a dilute methanol solution (w A = 0.05 mass fraction alcohol). A constant flow of
500 kg/min of pure water is suddenly introduced into the tank and a constant rate of
withdrawal of 500 kg/min of solution is started. These two flows are continued and remain
constant. Assuming that the densities of the solutions are the same and that the total contents
of the tank remain constant at 10000 kg of solution, calculate the time for the alcohol content to
drop to 1.0 wt%.
A19 :Ans. 32.2 min
2.6 -6 .
Ov er a ll M a ss Ba la nce for  Unst ea d y -S t a t e Pr ocess. A storage vessel is well stirred and
contains 500 kg of total solution with a concentration of 5.0% salt. A constant flow rate of 900
kg/h of salt solution containing 16.67% salt is suddenly introduced into the tank and a constant
withdrawal rate of 600 kg/h is also started. These two flows remain constant thereafter. Derive
an equation relating the outlet withdrawal concentration as a function of time. Also, calculate
the concentration after 2.0 h.
2.6 -7
M a ss Ba la nce for  Flow  of S u cr ose S olu t ion. A 20 wt % sucrose (sugar) solution having a
density of 1074 kg/m3 is flowing through the same piping system as in Example 2.6-1 (Fig. 2.6-
2). The flow rate entering pipe 1 is 1.892 m3/h. The flow divides equally in each of pipes 3.
Calculate the following:

a.  The velocity in m/s in pipes 2 and 3.

b.  The mass velocity G kg/m2 · s in pipes 2 and 3.

2.7-1.
K inet ic-Ener g y  Velocit y  C or r ect ion Fa ct or  for  Tu r b u lent  Flow . Derive the equation to
determine the value of α, the kinetic-energy velocity correction factor, for turbulent flow. Use Eq.
(2.7-20) to approximate the velocity profile and substitute this into Eq. (2.7-15) to obtain (ν3)av .
Then use Eqs. (2.7-20), (2.6-17), and (2.7-14) to obtain α.

A22:Ans. α = 0.9448
2.7-2.
Flow  Bet w een Pa r a llel Pla t es a nd  K inet ic-Ener g y  C or r ect ion Fa ct or . The equation for
the velocity profile of a fluid flowing in laminar flow between two parallel plates is given in
Problem 2.6-4. Derive the equation to determine the value of the kinetic-energy velocity
correction factor α. [Hint: First derive an equation relating ν to νav . Then derive the equation for

(ν3)av  and, finally, relate these results to α.]
2.7-3.
Temp er a t u r e Dr op  in Thr ot t ling  Va lv e a nd  Ener g y  Ba la nce. Steam is flowing through
an adiabatic throttling valve (no heat loss or external work). Steam enters point 1 upstream of
the valve at 689 kPa abs and 171.1°C and leaves the valve (point 2) at 359 kPa. Calculate the
temperature t 2 at the outlet. [Hint: Use Eq. (2.7-21) for the energy balance and neglect the
kinetic-energy and potential-energy terms as shown in Example 2.7-1. Obtain the enthalpy H1
from Appendix A.2, steam tables. For H2, linear interpolation of the values in the table will have
to be done to obtain t 2.] Use SI units.
A24 :Ans. t 2 = 160.6°C
2.7-4 .
Ener g y  Ba la nce on a  Hea t  Excha ng er  a nd  a  Pu mp . Water at 93.3°C is being pumped
from a large storage tank at 1 atm abs at a rate of 0.189 m3/min by a pump. The motor that
drives the pump supplies energy to the pump at the rate of 1.49 kW. The water is pumped
through a heat exchanger, where it gives up 704 kW of heat and is then delivered to a large open
storage tank at an elevation of 15.24 m above the first tank. What is the final temperature of the
water to the second tank? Also, what is the gain in enthalpy of the water due to the work input?
(Hint: Be sure to use the steam tables for the enthalpy of the water. Neglect any kinetic-energy
changes but not potential-energy changes.)
A25:Ans. t 2 = 38.2°C, work input gain = 0.491 kJ/kg
2.7-5.
S t ea m Boiler  a nd  Ov er a ll Ener g y  Ba la nce. Liquid water under pressure at 150 kPa enters
a boiler at 24°C through a pipe at an average velocity of 3.5 m/s in turbulent flow. The exit steam
leaves at a height of 25 m above the liquid inlet at 150°C and 150 kPa absolute, and the velocity
in the outlet line is 12.5 m/s in turbulent flow. The process is steady state. How much heat must
be added per kg of steam?
2.7-6 .
Ener g y  Ba la nce on a  Flow  S y st em w it h a  Pu mp  a nd  Hea t  Excha ng er . Water stored in
a large, well-insulated storage tank at 21.0°C and atmospheric pressure is being pumped at
steady state from this tank by a pump at the rate of 40 m3/h. The motor driving the pump
supplies energy at the rate of 8.5 kW. The water is used as a cooling medium and passes through
a heat exchanger, where 255 kW of heat is added to the water. The heated water then flows to a
second large, vented tank, which is 25 m above the first tank. Determine the final temperature of
the water delivered to the second tank.

2.7-7.
M echa nica l-Ener g y  Ba la nce in Pu mp ing  S oy b ea n Oil. Soybean oil is being pumped
through a uniform-diameter pipe at a steady mass-flow rate. A pump supplies 209.2 J/kg mass
of fluid flowing. The entrance abs pressure in the inlet pipe to the pump is 103.4 kN/m2. The exit
section of the pipe downstream from the pump is 3.35 m above the entrance and the exit
pressure is 172.4 kN/m2. Exit and entrance pipes are the same diameter. The fluid is in turbulent
flow. Calculate the friction loss in the system. See Appendix A.4 for the physical properties of
soybean oil. The temperature is 303 K.
A28:Ans. ∑F = 101.3 J/kg
2.7-8.
Pu mp  Hor sep ow er  in Br ine S y st em. A pump pumps 0.200 ft 3/s of brine solution having a
density of 1.15 g/cm3 from an open feed tank having a large cross-sectional area. The suction line
has an inside diameter of 3.548 in. and the discharge line from the pump a diameter of 2.067 in.
The discharge flow goes to an open overhead tank, and the open end of this line is 75 ft above the
liquid level in the feed tank. If the friction losses in the piping system are 18.0 ft lbf/lbm, what
pressure must the pump develop and what is the horsepower of the pump if the efficiency is
70%? The flow is turbulent.
2.7-9 .
Pr essu r e M ea su r ement s fr om Flow s. Water having a density of 998 kg/m3 is flowing at the
rate of 1.676 m/s in a 3.068-in.-diameter horizontal pipe at a pressure p1 of 68.9 kPa abs. It then
passes to a pipe having an inside diameter of 2.067 in.

a.  Calculate the new pressure p2 in the 2.067-in. pipe. Assume no friction losses.

b.  If the piping is vertical and the flow is upward, calculate the new pressure p2. The
pressure tap for p2 is 0.457 m above the tap for p1.

A30:Ans. (a) p2 = 63.5 kPa; (b) p2 = 59.1 kPa
2.7-10.Dr a ining  C ot t onseed  Oil fr om a  Ta nk . A cylindrical tank 1.52 m in diameter and 7.62 m
high contains cottonseed oil having a density of 917 kg/m3. The tank is open to the atmosphere.
A discharge nozzle of inside diameter 15.8 mm and cross-sectional area A2 is located near the
bottom of the tank. The surface of the liquid is located at H = 6.1 m above the center line of the
nozzle. The discharge nozzle is opened, draining the liquid level from H = 6.1 m to H = 4.57 m.
Calculate the time in seconds to do this. [Hint: The velocity on the surface of the reservoir is
small and can be neglected. The velocity ν2 m/s in the nozzle can be calculated for a given H by
Eq. (2.7-36). However, H, and hence ν2, are varying. Set up an unsteady-state mass balance as
follows: The volumetric flow rate in the tank is (At dH)/dt, where At is the tank cross section in

m2 and At dH is the m3 liquid flowing in dt s. This rate must equal the negative of the volumetric

rate in the nozzle, or −A2ν2 m3/s. The negative sign is present since dH is the negative of ν2.
Rearrange this equation and integrate between H = 6.1 m at t = 0 and H = 4.57 m at t = t F.]

A31:Ans. t F = 1388 s
2.7-11.
Fr ict ion Loss in Tu r b ine W a t er  Pow er  S y st em. Water is stored in an elevated reservoir. To
generate power, water flows from this reservoir down through a large conduit to a turbine and
then through a similar-sized conduit. At a point in the conduit 89.5 m above the turbine, the
pressure is 172.4 kPa, and at a level 5 m below the turbine, the pressure is 89.6 kPa. The water
flow rate is 0.800 m3/s. The output of the shaft of the turbine is 658 kW. The water density is
1000 kg/m3. If the efficiency of the turbine in converting the mechanical energy given up by the
fluid to the turbine shaft is 89% (ηt = 0.89), calculate the friction loss in the turbine in J/kg.
Note that in the mechanical-energy-balance equation, the Ws is equal to the output of the shaft
of the turbine over ηt.
A32:Ans. ∑F = 85.3 J/kg
2.7-12.
Pip eline Pu mp ing  of Oil. A pipeline laid cross-country carries oil at the rate of 795 m3/d. The
pressure of the oil is 1793 kPa gage leaving pumping station 1. The pressure is 862 kPa gage at
the inlet to the next pumping station, 2. The second station is 17.4 m higher than the first
station. Calculate the lost work ( ∑F friction loss) in J/kg mass oil. The oil density is 769 kg/m3.
2.7-13.
Test  of C ent r ifu g a l Pu mp  a nd  M echa nica l-Ener g y  Ba la nce. A centrifugal pump is
being tested for performance, and during the test the pressure reading in the 0.305-m-diameter
suction line just adjacent to the pump casing is −20.7 kPa (vacuum below atmospheric
pressure). In the discharge line with a diameter of 0.254 m at a point 2.53 m above the suction
line, the pressure is 289.6 kPa gage. The flow of water from the pump is measured as 0.1133
m3/s. (The density can be assumed as 1000 kg/m3.) Calculate the kW input of the pump.
A34 :Ans. 38.11 kW
2.7-14 .
Fr ict ion Loss in Pu mp  a nd  Flow  S y st em. Water at 20°C is pumped from the bottom of a
large storage tank where the pressure is 310.3 kPa gage to a nozzle which is 15.25 m above the
tank bottom and discharges to the atmosphere with a velocity in the nozzle of 19.81 m/s. The
water flow rate is 45.4 kg/s. The efficiency of the pump is 80% and 7.5 kW are furnished to the
pump shaft. Calculate the following:

a.  The friction loss in the pump.
b.  The friction loss in the rest of the process.

2.7-15.
Pow er  for  Pu mp ing  in Flow  S y st em. Water is being pumped from an open water reservoir
at the rate of 2.0 kg/s at 10°C to an open storage tank 1500 m away. The pipe used is schedule

40 3 in. pipe and the frictional losses in the system are 625 J/kg. The surface of the water
reservoir is 20 m above the level of the storage tank. The pump has an efficiency of 75%.

a.  What is the kW power required for the pump?

b.  If the pump is not present in the system, will there be a flow?

A36 :Ans. (a) 1.143 kW
2.8-1.
M oment u m Ba la nce in a  R ed u cing  Bend . Water is flowing at steady state through the
reducing bend in Fig. 2.8-3. The angle α2 = 90° (a right-angle bend). The pressure at point 2 is

1.0 atm abs. The flow rate is 0.020 m3/s and the diameters at points 1 and 2 are 0.050 m and
0.030 m, respectively. Neglect frictional and gravitational forces. Calculate the resultant forces
on the bend in newtons and lb force. Use ρ = 1000 kg/m3.
A37:Ans. −Rx = +450.0 N, −Ry  = −565.8 N.
2.8-2.
For ces on R ed u cing  Bend . Water is flowing at steady state and 363 K at a rate of 0.0566
m3/s through a 60° reducing bend (α2 = 60°) in Fig. 2.8-3. The inlet pipe diameter is 0.1016 m

and the outlet 0.0762 m. The friction loss in the pipe bend can be estimated as   Neglect
gravity forces. The exit pressure p2 = 111.5 kN/m2 gage. Calculate the forces on the bend in
newtons.
A38:Ans. −Rx = +1344 N, −Ry  = −1026 N
2.8-3.
For ce of W a t er  S t r ea m on a  W a ll. Water at 298 K discharges from a nozzle and travels
horizontally, hitting a flat, vertical wall. The nozzle has a diameter of 12 mm and the water
leaves the nozzle with a flat velocity profile at a velocity of 6.0 m/s. Neglecting frictional
resistance of the air on the jet, calculate the force in newtons on the wall.
A39 :Ans. −Rx = 4.059 N
2.8-4 .
Flow  Thr ou g h a n Exp a nd ing  Bend . Water at a steady-state rate of 0.050 m3/s is flowing
through an expanding bend that changes direction by 120°. The upstream diameter is 0.0762 m
and the downstream is 0.2112 m. The upstream pressure is 68.94 kPa gage. Neglect energy
losses within the elbow and calculate the downstream pressure at 298 K. Also calculate Rx and
Ry .
2.8-5.
For ce of S t r ea m on a  W a ll. Repeat Problem 2.8-3 for the same conditions except that the
wall is inclined 45° to the vertical. The flow is frictionless. Assume no loss in energy. The amount
of fluid splitting in each direction along the plate can be determined by using the continuity
equation and a momentum balance. Calculate this flow division and the force on the wall.

A4 1:Ans. m2 = 0.5774 kg/s, m3 = 0.09907 kg/s, −Rx = 2.030 N, −Ry  = −2.030 N (force on wall).
2.8-6 .M oment u m Ba la nce for  Fr ee Jet  on a  C u r v ed , Fixed  Va ne. A free jet having a velocity of
30.5 m/s and a diameter of 5.08 × 10−2 m is deflected by a curved, fixed vane as in Fig. 2.8-5a.
However, the vane is curved downward at an angle of 60° instead of upward. Calculate the force
of the jet on the vane. The density is 1000 kg/m3.

A4 2:Ans. −Rx = 942.8 N, −Ry  = 1633 N
2.8-7.
M oment u m Ba la nce for  Fr ee Jet  on a  U-Ty p e, Fixed  Va ne. A free jet having a velocity of
30.5 m/s and a diameter of 1.0 × 10−2 m is deflected by a smooth, fixed vane as in Fig. 2.8-5a.
However, the vane is in the form of a U so that the exit jet travels in a direction exactly opposite
to the entering jet. Calculate the force of the jet on the vane. Use ρ = 1000 kg/m3.
A4 3:Ans. −Rx = 146.1 N, −Ry  = 0
2.8-8.
M oment u m Ba la nce on R ed u cing  Elb ow  a nd  Fr ict ion Losses. Water at 20°C is flowing
through a reducing bend, where α2 (see Fig. 2.8-3) is 120°. The inlet pipe diameter is 1.829 m,

the outlet is 1.219 m, and the flow rate is 8.50 m3/s. The exit point z2 is 3.05 m above the inlet

and the inlet pressure is 276 kPa gage. Friction losses are estimated as 0.5  /2 and the mass of
water in the elbow is 8500 kg. Calculate the forces Rx and Ry  and the resultant force on the
control-volume fluid.
2.8-9 .
M oment u m Velocit y  C or r ect ion Fa ct or  β  for  Tu r b u lent  Flow . Determine the
momentum velocity correction factor β for turbulent flow in a tube. Use Eq. (2.7-20) for the
relationship between ν and position.
2.9 -1.
Film of W a t er  on W et t ed -W a ll Tow er . Pure water at 20°C is flowing down a vertical
wetted-wall column at a rate of 0.124 kg/s · m. Calculate the film thickness and the average
velocity.
A4 6 : Ans.  δ = 3.370 × 10−4 m, ν  = 0.3687 m/s
z av
2.9 -2.
S hell M oment u m Ba la nce for  Flow  Bet w een Pa r a llel Pla t es. A fluid of constant density
is flowing in laminar flow at steady state in the horizontal x direction between two flat and
parallel plates. The distance between the two plates in the vertical y direction is 2y 0. Using a
shell momentum balance, derive the equation for the velocity profile within this fluid and the
maximum velocity for a distance L m in the x direction. [Hint: See the method used in Section
2.9B to derive Eq. (2.9-9). One boundary condition used is dνx/dy = 0 at y = 0.]
A4 7:  

Ans.

2.9 -3.
Velocit y  Pr ofile for  Non-New t onia n Flu id . The stress rate of shear for a non-Newtonian
fluid is given by
where K and n are constants. Find the relation between velocity and radial position r for this
incompressible fluid at steady state. [Hint: Combine the equation given here with Eq. (2.9-6).
Then raise both sides of the resulting equation to the 1/n power and integrate.]
A4 8:  

Ans.
2.9 -4 .
S hell M oment u m Ba la nce for  Flow  Dow n a n Inclined  Pla ne. Consider the case of a
Newtonian fluid in steady-state laminar flow down an inclined plane surface that makes an
angle θ with the horizontal. Using a shell momentum balance, find the equation for the velocity
profile within the liquid layer having a thickness L and the maximum velocity of the free surface.
(Hint: The convective-momentum terms cancel for fully developed flow and the pressure-force
terms also cancel, because of the presence of a free surface. Note that there is a gravity force on
the fluid.)
A4 9 : Ans.  ν    = ρgL2 sin θ/2μ
x max
2.10-1.
Viscosit y  M ea su r ement  of a  Liq u id . One use of the Hagen–Poiseuille equation (2.10-2) is
in determining the viscosity of a liquid by measuring the pressure drop and velocity of the liquid
in a capillary of known dimensions. The liquid used has a density of 912 kg/m3, and the
capillary has a diameter of 2.222 mm and a length of 0.1585 m. The measured flow rate is 5.33 ×
10−7  m3/s of liquid and the pressure drop 131 mm of water (density 996 kg/m3). Neglecting end
effects, calculate the viscosity of the liquid in Pa · s.
A50: Ans.  μ = 9.06 × 10−3 Pa · s
2.10-2.
Fr ict iona l Pr essu r e Dr op  in Flow  of Oliv e Oil. Calculate the frictional pressure drop in
pascal for olive oil at 293 K flowing through a commercial pipe having an inside diameter of
0.0525 m and a length of 76.2 m. The velocity of the fluid is 1.22 m/s. Use the friction factor
method. Is the flow laminar or turbulent? Use physical data from Appendix A.4.
2.10-3.
Fr ict iona l Loss in S t r a ig ht  Pip e a nd  Effect  of Ty p e of Pip e. A liquid having a density of
801 kg/m3 and a viscosity of 1.49 × 10−3 Pa · s is flowing through a horizontal straight pipe at a

velocity of 4.57 m/s. The commercial steel pipe is  in. nominal pipe size, schedule 40. For a
length of pipe of 61 m, do as follows:

a.  Calculate the friction loss Ff.

b.  For a smooth tube of the same inside diameter, calculate the friction loss. What is the
percent reduction of Ff for the smooth tube?
A52:Ans. (a) 348.9 J/kg; (b) 274.2 J/kg (91.7 ft · lbf/lbm), 21.4% reduction
2.10-4 .
Tr ia l-a nd -Er r or  S olu t ion for  Hy d r a u lic Dr a ina g e. In a hydraulic project a cast-iron pipe
having an inside diameter of 0.156 m and a 305-m length is used to drain wastewater at 293 K.
The available head is 4.57 m of water. Neglecting any losses in fittings and joints in the pipe,
calculate the flow rate in m3/s. (Hint: Assume the physical properties of pure water. The
solution is trial and error, since the velocity appears in NRe, which is needed to determine the
friction factor. As a first trial, assume that ν = 1.7 m/s.)
2.10-5.
M echa nica l-Ener g y  Ba la nce a nd  Fr ict ion Losses. Hot water is being discharged from a
storage tank at the rate of 0.223 ft 3/s. The process flow diagram and conditions are the same as
given in Example 2.10-6, except for different nominal pipe sizes of schedule 40 steel pipe as

follows. The 20-ft-long outlet pipe from the storage tank is   pipe instead of 4-in. pipe. The
other piping, which was 2-in. pipe, is now 2.5-in. pipe. Note that now a sudden expansion

occurs after the elbow in the   pipe to a   pipe.


2.10-6 .
Fr ict ion Losses a nd  Pu mp  Hor sep ow er . Hot water in an open storage tank at 82.2°C is
being pumped at the rate of 0.379 m3/min from the tank. The line from the storage tank to the
pump suction is 6.1 m of 2-in. schedule 40 steel pipe and it contains three elbows. The discharge
line after the pump is 61 m of 2-in. pipe and contains two elbows. The water discharges to the
atmosphere at a height of 6.1 m above the water level in the storage tank.

a.  Calculate all frictional losses Σ F.

b.  Make a mechanical-energy balance and calculate WS of the pump in J/kg.

c.  What is the kW power of the pump if its efficiency is 75%?

A55:Ans. (a) Σ F = 122.8 J/kg; (b) WS = −186.9 J/kg; (c) 1.527 kW
2.10-7.
Pr essu r e Dr op  of a  Flow ing  G a s. Nitrogen gas is flowing through a 4-in. schedule 40
commercial steel pipe at 298 K. The total flow rate is 7.40 × 10−2 kg/s and the flow can be
assumed as isothermal. The pipe is 3000 m long and the inlet pressure is 200 kPa. Calculate the
outlet pressure.

A56 :Ans. p2 = 188.5 kPa
2.10-8.
Ent r y  Leng t h for  Flow  in a  Pip e. Air at 10°C and 1.0 atm abs pressure is flowing at a
velocity of 2.0 m/s inside a tube having a diameter of 0.012 m.

a.  Calculate the entry length.

b.  Calculate the entry length for water at 10°C and the same velocity.

2.10-9 .
Fr ict ion Loss in Pu mp ing  Oil t o Pr essu r ized  Ta nk . An oil having a density of 833 kg/m3
and a viscosity of 3.3 × 10−3 Pa · s is pumped from an open tank to a pressurized tank held at
345 kPa gage. The oil is pumped from an inlet at the side of the open tank through a line of
commercial steel pipe having an inside diameter of 0.07792 m at the rate of 3.494 × 10−3 m3/s.
The length of straight pipe is 122 m, and the pipe contains two elbows (90°) and a globe valve
half open. The level of the liquid in the open tank is 20 m above the liquid level in the pressurized
tank. The pump efficiency is 65%. Calculate the kW power of the pump.
2.10-
Flow  in a n Annu lu s a nd  Pr essu r e Dr op . Water flows in the annulus of a horizontal,
10.
concentric-pipe heat exchanger and is being heated from 40°C to 50°C in the exchanger, which
has a length of 30 m of equivalent straight pipe. The flow rate of the water is 2.90 × 10−3 m3/s.
The inner pipe is 1-in. schedule 40 and the outer is 2-in. schedule 40. What is the pressure drop?
Use an average temperature of 45°C for bulk physical properties. Assume that the wall
temperature is an average of 4°C higher than the average bulk temperature so that a correction
can be made for the effect of heat transfer on the friction factor.
2.11-1.
Der iv a t ion of M a ximu m Velocit y  for  Isot her ma l C omp r essib le Flow . Starting with
Eq. (2.11-9), derive Eqs. (2.11-11) and (2.11-12) for the maximum velocity in isothermal
compressible flow.
2.11-2.
Pr essu r e Dr op  in C omp r essib le Flow . Methane gas is being pumped through a 305-m
length of 52.5-mm-ID steel pipe at the rate of 41.0 kg/m2 · s. The inlet pressure is p1 = 345 kPa
abs. Assume isothermal flow at 288.8 K.

a.  Calculate the pressure p2 at the end of the pipe. The viscosity is 1.04 × 10−5 Pa · s.

b.  Calculate the maximum velocity that can be attained at these conditions and compare
with the velocity in part (a).

A6 1:Ans. (a) p2 = 298.4 kPa; (b) νmax = 387.4 m/s, ν2 = 20.62 m/s
2.11-3.
Pr essu r e Dr op  in Isot her ma l C omp r essib le Flow . Air at 288 K and 275 kPa abs enters a
pipe and is flowing in isothermal compressible flow in a commercial pipe having an ID of 0.080
m. The length of the pipe is 60 m. The mass velocity at the entrance to the pipe is 165.5 kg/m2 ·
s. Assume 29 for the molecular weight of air. Calculate the pressure at the exit. Also, calculate
the maximum allowable velocity that can be attained and compare with the actual.
                             
                                                 
                                             
                                               
     

Chapter 3. Principles of Momentum Transfer and
Applications
FLOW PAST IMMERSED OBJECTS AND PACKED AND FLUIDIZED BEDS

MEASUREMENT OF FLOW OF FLUIDS

PUMPS AND GAS-MOVING EQUIPMENT

AGITATION AND MIXING OF FLUIDS AND POWER REQUIREMENTS

NON-NEWTONIAN FLUIDS

DIFFERENTIAL EQUATIONS OF CONTINUITY

DIFFERENTIAL EQUATIONS OF MOMENTUM TRANSFER OR MOTION

USE OF DIFFERENTIAL EQUATIONS OF CONTINUITY AND MOTION

OTHER METHODS FOR SOLUTION OF DIFFERENTIAL EQUATIONS OF MOTION

BOUNDARY-LAYER FLOW AND TURBULENCE

DIMENSIONAL ANALYSIS IN MOMENTUM TRANSFER

PROBLEMS

REFERENCES
                             
                                                 
                                             
                                               
     

3.1. FLOW PAST IMMERSED OBJECTS AND PACKED AND
FLUIDIZED BEDS

3.1A. De finition of Dr ag C oe fficie nt for  Flow  Past Im m e r se d  Ob je cts

1. Int r od u ct ion a nd  t y p es of d r a g

In Chapter 2 we were concerned primarily with the momentum transfer and frictional losses for flow of
fluids inside conduits or pipes. In this section we consider in some detail the flow of fluids around solid,
immersed objects.

The flow of fluids outside immersed bodies appears in many chemical engineering applications and other
processing applications. These occur, for example, in flow past spheres in settling, flow through packed
beds in drying and filtration, flow past tubes in heat exchangers, and so on. It is useful to be able to
predict the frictional losses and/or the force on the submerged objects in these various applications.

In the examples of fluid friction inside conduits that we considered in Chapter 2, the transfer of
momentum perpendicular to the surface resulted in a tangential shear stress or drag on the smooth
surface parallel to the direction of flow. This force exerted by the fluid on the solid in the direction of flow
is called skin or wall drag. For any surface in contact with a flowing fluid, skin friction will exist. In
addition to skin friction, if the fluid is not flowing parallel to the surface but must change direction to
pass around a solid body such as a sphere, significant additional frictional losses will occur; this is called
form drag.

In Fig. 3.1-1a the flow of fluid is parallel to the smooth surface of the flat, solid plate, and the force F in
newtons on an element of area dA m2 of the plate is the wall shear stress τw  times the area dA, or τw  dA.
The total force is the sum of the integrals of these quantities evaluated over the entire area of the plate.
Here the transfer of momentum to the surface results in a tangential stress or skin drag on the surface.

Figure 3.1-1. Flow past immersed objects : (a) flat plate, (b) sphere, (c) str eamlined object.


In many cases, however, the immersed body is a blunt-shaped solid which presents various angles to the
direction of the fluid flow. As shown in Fig. 3.1-1b, the free-stream velocity is ν0 and is uniform on
approaching the blunt-shaped body suspended in a very large duct. Lines called streamlines represent
the path of fluid elements around the suspended body. The thin boundary layer adjacent to the solid
surface is shown as a dashed line; at the edge of this layer the velocity is essentially the same as the bulk
fluid velocity adjacent to it. At the front center of the body, called the stagnation point, the fluid velocity
will be zero; boundary-layer growth begins at this point and continues over the surface until the layer
separates. The tangential stress on the body because of the velocity gradient in the boundary layer is the
skin friction. Outside the boundary layer the fluid changes direction to pass around the solid and also
accelerates near the front and then decelerates. Because of these effects, an additional force is exerted by
the fluid on the body. This phenomenon, called form drag, is in addition to the skin drag in the
boundary layer.

In Fig. 3.1-1b, as shown, separation of the boundary layer occurs and a wake, covering the entire rear of
the object, occurs where large eddies are present and contribute to the form drag. The point of separation
depends on the shape of the particle, Reynolds number, and so on, and is discussed in detail elsewhere
(S3).

Form drag for bluff bodies can be minimized by streamlining the body (Fig. 3.1-1c), which forces the
separation point toward the rear of the body, greatly reducing the size of the wake. Additional discussion
of turbulence and boundary layers is given in Section 3.10.

2. Dr a g  coefficient

From the preceding discussion it is evident that the geometry of the immersed solid is a major factor in
determining the amount of total drag force exerted on the body. Correlations of the geometry and flow
characteristics for solid objects suspended or held in a free stream (immersed objects) are similar in
concept and form to the friction factor-Reynolds number correlation given for flow inside conduits. In
flow through conduits, the friction factor was defined as the ratio of the drag force per unit area (shear
stress) to the product of density times velocity head, as given in Eq. (2.10-4).
In a similar manner, for flow past immersed objects the drag coefficient C D is defined as the ratio of the

total drag force per unit area to  /2:

Equation 3.1-1

where FD is the total drag force in N, Ap is an area in m2, C D is dimensionless, ν0 is free-stream velocity in

m/s, and ρ is density of fluid in kg/m3. In English units, FD is in 1bf, ν0 is in ft/s, ρ is in 1bm/ft 3, and Ap

is in ft 2. The area Ap used is the area obtained by projecting the body on a plane perpendicular to the line

of flow. For a sphere, Ap =  , where Dp is sphere diameter; for a cylinder whose axis is perpendicular
to the flow direction, Ap = LDP, where L = cylinder length. Solving Eq. (3.1-1) for the total drag force,

Equation 3.1-2

The Reynolds number for a given solid immersed in a flowing liquid is

Equation 3.1-3

where G0 = ν0ρ.

3.1B. Flow  Past S p he r e , Long C ylind e r , and  Disk

For each particular shape of object and orientation of the object with respect to the direction of flow, a
different relation of C D versus NRe exists. Correlations of drag coefficient versus Reynolds number are
shown in Fig. 3.1-2 for spheres, long cylinders, and disks. The face of the disk and the axis of the cylinder
are perpendicular to the direction of flow. These curves have been determined experimentally. However,
in the laminar region for low Reynolds numbers, less than about 1.0, the experimental drag force for a
sphere is the same as the theoretical Stokes' law equation as follows:

Equation 3.1-4
Figure 3.1-2. Drag coefficients for flow past immersed spheres, long cylinders, and disks. (Reprinted with
permission from C. E. Lapple and C. B. Shepherd, Ind. Eng. Chem., 32, 606 (1940). Copyright by the American
Chemical Society.)

Combining Eqs. (3.1-2) and (3.1-4) and solving for C D, the drag coefficient predicted by Stokes' law is

Equation 3.1-5

The variation of C D with NRe (Fig. 3.1-2) is quite complicated because of the interaction of the factors that
control skin drag and form drag. For a sphere, as the Reynolds number is increased beyond the Stokes'
law range, separation occurs and a wake is formed. Further increases in NRe cause shifts in the

separation point. At about NRe = 3 × 105 the sudden drop in C D is the result of the boundary layer
becoming completely turbulent and the point of separation moving downstream. In the region of NRe

about 1 × 103 to 2 × 105, the drag coefficient is approximately constant for each shape and C D = 0.44 for

a sphere. Above NRe about 5 × 105, the drag coefficients are again approximately constant, with C D being
0.13 for a sphere, 0.33 for a cylinder, and 1.12 for a disk. Additional discussions and theory concerning
flow past spheres are given in Section 3.9E.

For derivations of theory and detailed discussions of the drag force for flow parallel to a flat plate, Section
3.10 on boundary-layer flow and turbulence should be consulted. The flow of fluids normal to banks of
cylinders or tubes occurs in heat exchangers and other processing applications. The banks of tubes can be
arranged in a number of different geometries. Because of the many possible geometric tube configurations
and spacings, it is not possible to have one correlation for the data on pressure drop and friction factors.
Details of the many correlations available are given elsewhere (P1).

EXAMPLE 3.1-1. Force on a Submerged Sphere
Air at 37.8°C and 101.3 kPa absolute pressure flows at a velocity of 23 m/s past a sphere
having a diameter of 42 mm. What are the drag coefficient C D and the force on the sphere?

S olu t ion: From Appendix A.3, for air at 37.8°C, ρ = 1.137 kg/m3 and μ = 1.90 × 10-5 Pa · s.
Also, Dp = 0.042 m and ν0 = 23.0 m/s. Using Eq. (3.1-3),

From Fig. 3.1-2 for a sphere, C D = 0.47. Substituting into Eq. (3.1-2), where Ap =   for a


sphere,

EXAMPLE 3.1-2. Force on a Cylinder in a Tunnel
Water at 24°C is flowing past a long cylinder at a velocity of 1.0 m/s in a large tunnel. The axis
of the cylinder is perpendicular to the direction of flow. The diameter of the cylinder is 0.090
m. What is the force per meter length on the cylinder?

S olu t ion: From Appendix A.2, for water at 24°C, ρ = 997.2 kg/m3  and μ = 0.9142 × 10−3  Pa ·


s. Also, Dp = 0.090 m, L = 1.0 m, and v0 = 1.0 m/s. Using Eq. (3.1-3),

From Fig. 3.1-2 for a long cylinder, C D  = 1.4. Substituting into Eq. (3.1-2), where Ap = LDp =

1.0(0.090) = 0.090 m2 ,
3.1C . Flow  in Packe d  Be d s

1. Int r od u ct ion

A system of considerable importance in chemical and other process engineering fields is the packed bed
or packed column, which is used for a fixed-bed catalytic reactor, adsorption of a solute, absorption, filter
bed, and so on. The packing material in the bed may be spheres, irregular particles, cylinders, or various
kinds of commercial packings. In the discussion to follow it is assumed that the packing is everywhere
uniform and that little or no channeling occurs. The ratio of diameter of the tower to packing diameter
should be a minimum of 8:1 to 10:1 for wall effects to be small. In the theoretical approach used, the
packed column is regarded as a bundle of crooked tubes of varying cross-sectional area. The theory
developed in Chapter 2 for single straight tubes is used to develop the results for the bundle of crooked
tubes.

2. La mina r  flow  in p a ck ed  b ed s

Certain geometric relations for particles in packed beds are used in the derivations for flow. The void
fraction ε in a packed bed is defined as

Equation 3.1-6

The specific surface of a particle a v  in m−1 is defined as

Equation 3.1-7

where Sp is the surface area of a particle in m2  and vp the volume of a particle in m3 . For a spherical


particle,

Equation 3.1-8

where Dp is diameter in m. For a packed bed of nonspherical particles, the effective particle diameter Dp
is defined as

Equation 3.1-9
Since (1 - ε) is the volume fraction of particles in the bed,

Equation 3.1-10

where a is the ratio of total surface area in the bed to total volume of bed (void volume plus particle
volume) in m−1.

EXAMPLE 3.1-3. Surface Area in Packed Bed of Cylinders
A packed bed is composed of cylinders having a diameter D = 0.02 m and a length h = D. The
bulk density of the overall packed bed is 962 kg/m3 and the density of the solid cylinders is
1600 kg/m3.

a.  Calculate the void fraction ε.

b.  Calculate the effective diameter Dp of the particles.

c.  Calculate the value of a in Eq. (3.1-10).

S olu t ion: For part (a), taking 1.00 m3 of packed bed as a basis, the total mass of the bed is
(962 kg/m3 )(1.00 m3) = 962 kg. This mass of 962 kg is also the mass of the solid cylinders.
Hence, volume of cylinders = 962 kg/(1600 kg/m3) = 0.601 m3. Using Eq. (3.1-6),

For the effective particle diameter Dp in part (b), for a cylinder where h = D, the surface area of
a particle is

The volume vp of a particle is
Substituting into Eq. (3.1-7),

Finally, substituting into Eq. (3.1-9),

Hence, the effective diameter to use is Dp = D = 0.02 m. For part (c), using Eq. (3.1-10),

The average interstitial velocity in the bed is v m/s and is related to the superficial velocity v' based on
the cross section of the empty container by

Equation 3.1-11

The hydraulic radius r H for flow defined in Eq. (2.10-21) is modified as follows (B2):

Equation 3.1-12

Combining Eqs. (3.1-10) and (3.1-12),

Equation 3.1-13
Since the equivalent diameter D for a channel is D = 4r H, the Reynolds number for a packed bed is as
follows, using Eq. (3.1-13) and v' = εv:

Equation 3.1-14

For packed beds Ergun (E1) defined the Reynolds number as above but without the 4/6 term:

Equation 3.1-15

where G' = ν'ρ.

For laminar flow, the Hagen-Poiseuille equation (2.10-2) can be combined with Eq. (3.1-13) for r H and
Eq. (3.1-11) to give

Equation 3.1-16

The true ΔL is larger because of the tortuous path, and use of the hydraulic radius predicts too large a v'.
Experimental data show that the constant should be 150, which gives the Blake-Kozeny equation for
laminar flow, void fractions less than 0.5, effective particle diameter Dp, and NRe,p < 10:

Equation 3.1-17

3. Tu r b u lent  flow  in p a ck ed  b ed s

For turbulent flow we use the same procedure by starting with Eq. (2.10-5) and substituting Eqs. (3.1-11)
and (3.1-13) into this equation to obtain

Equation 3.1-18
For highly turbulent flow the friction factor should approach a constant value. Also, it is assumed that
all packed beds should have the same relative roughness. Experimental data indicate that 3f = 1.75.
Hence, the final equation for turbulent flow for NRe,p > 1000, which is called the Burke-Plummer
equation, becomes

Equation 3.1-19

Adding Eq. (3.1-17) for laminar flow and Eq. (3.1-19) for turbulent flow, Ergun (E1) proposed the
following general equation for low, intermediate, and high Reynolds numbers, which has been tested
experimentally:

Equation 3.1-20

Rewriting Eq. (3.1-20) in terms of dimensionless groups,

Equation 3.1-21

See also Eq. (3.1-33) for another form of Eq. (3.1-21). The Ergun equation (3.1-21) can be used for gases by
taking the density ρ of the gas as the arithmetic average of the inlet and outlet pressures. The velocity v'
changes throughout the bed for a compressible fluid, but G' is a constant. At high values of NRe,p, Eqs.
(3.1-20) and (3.1-21) reduce to Eq. (3.1-19), and to Eq. (3.1-17) for low values. For large pressure drops
with gases, Eq. (3.1-20) can be written in differential form (P1).

EXAMPLE 3.1-4. Pressure Drop and Flow of Gases in
Packed Bed
Air at 311 K is flowing through a packed bed of spheres having a diameter of 12.7 mm. The void
fraction ε of the bed is 0.38 and the bed has a diameter of 0.61 m and a height of 2.44 m. The
air enters the bed at 1.10 atm abs at the rate of 0.358 kg/s. Calculate the pressure drop of the
air in the packed bed. The average molecular weight of air is 28.97.

S olu t ion: From Appendix A.3, for air at 311 K, μ = 1.90 × 10−5 Pa · s. The cross-sectional area
of the bed is A = (π/4)D2 = (π/4)(0.61)2 = 0.2922 m2. Hence, G' = 0.358/0.2922 = 1.225
kg/m2 · s (based on empty cross section of container or bed). Dp = 0.0127 m, ΔL = 2.44 m, and

inlet pressure p1 = 1.1(1.01325 × 105) = 1.115 × 105 Pa.
From Eq. (3.1-15),

To use Eq. (3.1-21) for gases, the density ρ to use is the average at the inlet p1 and outlet p2
pressures, or at (pl + p2)/2. This is trial and error since p2 is unknown. Assuming that Δp =

0.05 × 105 Pa, p2  = 1.115 × 105 - 0.05 × 105 = 1.065 × 105 Pa. The average pressure is pav  =

(1.115 × 105 + 1.065 × 105)/2 = 1.090 × 105 Pa. The average density to use is

Equation 3.1-22

Substituting into Eq. (3.1-21) and solving for Δp,

Solving, Δp = 0.0497 × 105 Pa. This is close enough to the assumed value, so a second trial is
not needed.

4 . S ha p e fa ct or s

Many particles in packed beds are often irregular in shape. The equivalent diameter of a particle is
defined as the diameter of a sphere having the same volume as this particle. The sphericity shape factor
φS of a particle is the ratio of the surface area of this sphere having the same volume as the particle to the

actual surface area of the particle. For a sphere, the surface area   and the volume 

 Hence, for any particle,  , where Sp is the actual surface area of the
particle and Dp is the diameter (equivalent diameter) of the sphere having the same volume as the
particle. Then

Equation 3.1-23
From Eq. (3.1-7),

Equation 3.1-24

Then Eq. (3.1-10) becomes

Equation 3.1-25

For a sphere, φS = 1.0. For a cylinder where diameter = length, φS is calculated to be 0.874, and for a
cube, φS is calculated to be 0.806. For granular materials it is difficult to measure the actual volume and
surface area to obtain the equivalent diameter. Hence, Dp is usually taken to be the nominal size from a
screen analysis or visual length measurements. The surface area is determined by adsorption
measurements or measurement of the pressure drop in a bed of particles. Then Eq. (3.1-23) is used to
calculate φS (Table 3.1-1). Typical values for many crushed materials are between 0.6 and 0.7. For
convenience, for the cylinder and the cube, the nominal diameter is sometimes used (instead of the
equivalent diameter), which then gives a shape factor of 1.0.

Table 3.1-1. Shape Factors (Sphericity) of Some Materials

Material Shape Factor, φS Reference

Spheres 1.0  

Cubes 0.81  
Cylinders, Dp  = h (length) 0.87  

Berl saddles 0.3 (B4)

Raschig rings 0.3 (C2)


Coal dust, pulverized 0.73 (C2)

Sand, average 0.75 (C2)


Crushed glass 0.65 (C2)

5. M ixt u r es of p a r t icles


For mixtures of particles of various sizes we can define a mean specific surface a vm as

Equation 3.1-26

where xi is volume fraction. Combining Eqs. (3.1-24) and (3.1-26),

Equation 3.1-27

where Dpm is the effective mean diameter for the mixture.

EXAMPLE 3.1-5. Mean Diameter for a Particle Mixture
A mixture contains three sizes of particles: 25% by volume of 25 mm size, 40% of 50 mm, and
35% of 75 mm. The sphericity is 0.68. Calculate the effective mean diameter.

S olu t ion: The following data are given: x1 = 0.25, Dp1 = 25 mm; x2 = 0.40, Dp2 = 50; x3 =
0.35, Dp3 = 75; φS = 0.68. Substituting into Eq. (3.1-27),

6 . Da r cy 's emp ir ica l la w  for  la mina r  flow

Equation (3.1-17) for laminar flow in packed beds shows that the flow rate is proportional to Δp and
inversely proportional to the viscosity μ and length ΔL. This is the basis for Darcy's law, as follows, for
purely viscous flow in consolidated porous media:

Equation 3.1-28

where v' is superficial velocity based on the empty cross section in cm/s, q' is flow rate in cm3/s, A is
empty cross section in cm2, μ is viscosity in cp, Δp is pressure drop in atm, ΔL is length in cm, and k is
permeability in (cm3 flow/s) · (cp) · (cm length)/(cm2 area) · (atm pressure drop). The units used for k of
cm2 · cp/s · atm are often given in darcy or in millidarcy (1/1000 darcy). Hence, if a porous medium has a
permeability of 1 darcy, a fluid of 1 cp viscosity will flow at 1 cm3/s per 1 cm2 cross section with a Δp of 1
atm per cm length. This equation is often used in measuring permeabilities of underground oil reservoirs.

3.1D. Flow  in Flu id ize d  Be d s

1. Ty p es of flu id iza t ion in b ed s

In a packed bed of small particles, when a fluid enters at sufficient velocity from the bottom and passes
up through the particles, the particles are pushed upward and the bed expands and becomes fluidized.
Two general types of fluidization, particulate fluidization and bubbling fluidization, can occur.

In particulate fluidization, as the fluid velocity is increased the bed continues to expand and remains
homogeneous for a time. The particles move farther apart and their motion becomes more rapid. The
average bed density at a given velocity is the same in all regions of the bed. An example is catalytic
cracking catalysts fluidized by gases. This type of fluidization is very desirable in promoting intimate
contact between the gas and solids. Liquids often give particulate fluidization.

In bubbling fluidization, the gas passes through the bed as voids or bubbles which contain few particles,
and only a small percentage of the gas passes in the spaces between individual particles. The expansion
of the bed is small as gas velocity is increased. Sand and glass beads provide examples of this behavior.
Since most of the gas is in bubbles, little contact occurs between the individual particles and the bubbles.

Particles which behave as above have been classified by Geldart (G2) into classes. Those called Type A,
which exhibit particulate fluidization in gases, fall into the following approximate ranges: For Δρ = (ρp −

ρ) = 2000 kg/m3, Dp = 20–125 μm; Δρ = 1000, Dp = 25−250; Δρ = 500, Dp = 40–450; Δρ = 200, Dp =
100–1000. For those called Type B, which exhibit bubbling fluidization, approximate ranges are as
follows: Δρ = 2000, Dp = 125−700 μm; Δρ = 1000, Dp = 250−1000; Δρ = 500, Dp = 450−1500; Δρ = 200,
Dp = 1000−2000.

Another type of behavior, called slugging, can occur in bubbling since the bubbles tend to coalesce and
grow as they rise in the bed. If the column is small in diameter with a deep bed, bubbles can become large
and fill the entire cross section and travel up the tower separated by slugs of solids.

2. M inimu m v elocit y  a nd  p or osit y  for  p a r t icu la t e flu id iza t ion

When a fluid flows upward through a packed bed of particles at low velocities, the particles remain
stationary. As the fluid velocity is increased, the pressure drop increases according to the Ergun equation
(3.1-20). Upon further increases in velocity, conditions finally occur where the force of the pressure drop
times the cross-sectional area equals the gravitational force on the mass of particles. Then the particles
begin to move, and this is the onset of fluidization or minimum fluidization. The fluid velocity at which

fluidization begins is the minimum fluidization velocity   in m/s based on the empty cross section of
the tower (superficial velocity).

The porosity of the bed when true fluidization occurs is the minimum porosity for fluidization, εmf. Some
typical values of εmf for various materials are given in Table 3.1-2. The bed expands to this voidage or
porosity before particle motion appears. This minimum voidage can be determined experimentally by
subjecting the bed to a rising gas stream and measuring the height of the bed Lmf in m. Generally, it
appears best to use gas as the fluid rather than a liquid, since liquids give somewhat higher values of εmf.
Table 3.1-2. Void Fraction, ε mf, at Minimum Fluidization Conditions (L2)

Particle Size, DP (mm)

Type of Particles 0.06 0.10 0.20 0.40

  Void fraction, εmf

Sharp sand (φS = 0.67) 0.60 0.58 0.53 0.49

Round sand (φS = 0.86) 0.53 0.48 0.43 (0.42)

Anthracite coal (φS = 0.63) 0.61 0.60 0.56 0.52

Absorption carbon 0.71 0.69    

Fischer Tropsch catalyst (φS = 0.58)   0.58 0.56 (0.54)

As stated earlier, the pressure drop increases as the gas velocity is increased until the onset of minimum
fluidization. Then, as the velocity is further increased, the pressure drop decreases very slightly, and then
it remains practically unchanged as the bed continues to expand or increase in porosity with increases in
velocity. The bed resembles a boiling liquid. As the bed expands with increase in velocity, it continues to
retain its top horizontal surface. Eventually, as the velocity is increased much further, entrainment of
particles from the actual fluidized bed becomes appreciable.

The relation between bed height L and porosity ε is as follows for a bed having a uniform cross-sectional
area A. Since the volume LA(1 − ε) is equal to the total volume of solids if they existed as one piece,

Equation 3.1-29

Equation 3.1-30

where L1 is height of bed with porosity ε1 and L2 is height with porosity ε2.

3. Pr essu r e d r op  a nd  minimu m flu id izing  v elocit y

As a first approximation, the pressure drop at the start of fluidization can be determined as follows. The
force obtained from the pressure drop times the cross-sectional area must equal the gravitational force
exerted by the mass of the particles minus the buoyant force of the displaced fluid:

Equation 3.1-31

Hence,
Equation 3.1-32

Often we have irregular-shaped particles in the bed, and it is more convenient to use the particle size and
shape factor in the equations. First we substitute for the effective mean diameter Dp the term φSDP,
where DP now represents the particle size of a sphere having the same volume as the particle and φS the
shape factor. Often, the value of DP is approximated by using the nominal size from a sieve analysis.
Then Eq. (3.1-20) for pressure drop in a packed bed becomes

Equation 3 1 33

where ΔL = L, bed length in m.

Equation (3.1-33) can now be used by a small extrapolation for packed beds to calculate the minimum

fluid velocity   at which fluidization begins by substituting   for v', εmf for ε, and Lmf for L, and


combining the result with Eq. (3.1-32) to give

Equation 3.1-34

Defining a Reynolds number as

Equation 3.1-35

Eq. (3.1-34) becomes

Equation 3.1-36
When NRe,mf < 20 (small particles), the first term of Eq. (3.1-36) can be dropped, and when NRe,mf >
1000 (large particles), the second term drops out.

If the terms εmf and/or φS are not known, Wen and Yu (W4) found for a variety of systems that

Equation 3.1-37

Substituting into Eq. (3.1-36), the following simplified equation is obtained:

Equation 3.1-38

This equation holds for a Reynolds-number range of 0.001 to 4000, with an average deviation of ± 25%.
Alternative equations are available in the literature (K1, W4).

EXAMPLE 3.1-6. Minimum Velocity for Fluidization
Solid particles having a size of 0.12 mm, a shape factor φS of 0.88, and a density of 1000

kg/m3 are to be fluidized using air at 2.0 atm abs and 25°C. The voidage at minimum
fluidizing conditions is 0.42.

a.  If the cross section of the empty bed is 0.30 m2 and the bed contains 300 kg of solid,
calculate the minimum height of the fluidized bed.

b.  Calculate the pressure drop at minimum fluidizing conditions.

c.  Calculate the minimum velocity for fluidization.

d.  Use Eq. (3.1-38) to calculate   assuming that data for φS and εmf are not available.

S olu t ion: For part (a), the volume of solids = 300 kg/(1000 kg/m3) = 0.300 m3. The height
the solids would occupy in the bed if ε1 = 0 is L1 = 0.300 m3/(0.30 m2 cross section) = 1.00 m.
Using Eq. (3.1-30) and calling Lmf = L2 and εmf = ε2,
Solving, Lmf = 1.724 m.

The physical properties of air at 2.0 atm and 25°C (Appendix A.3) are μ = 1.845 × 10-5  Pa · s, ρ
= 1.187 × 2 = 2.374 kg/m3 , and p = 2.0265 × 105  Pa. For the particle, DP  = 0.00012 m, ρp =

1000 kg/m3 , φS  = 0.88, and εmf = 0.42.

For part (b), using Eq. (3.1-32) to calculate Δp,

To calculate   for part (c), Eq. (3.1-36) is used:
[View full size image]

Solving,

Using the simplified Eq. (3.1-38) for part (d),
[View full size image]
Solving,   = 0.004618 m/s.

4 . Exp a nsion of flu id ized  b ed s

For the case of small particles and where NRe,f = Dpν'ρ/μ < 20, we can estimate the variation of porosity
or bed height L as follows. We assume that Eq. (3.1-36) applies over the whole range of fluid velocities,
with the first term being neglected. Then, solving for ν',

Equation 3.1-39

We find that all terms except ε are constant for the particular system, and ε depends upon ν'. This
equation can be used with liquids to estimate ε with ε < 0.80. However, because of clumping and other
factors, errors can occur when used for gases.

The flow rate in a fluidized bed is limited on the one hand by the minimum   and on the other by
entrainment of solids from the bed proper. This maximum allowable velocity is approximated as the

terminal settling velocity   of the particles. (See Section 13.3 for methods for calculating this settling
velocity.) Approximate equations for calculating the operating range are as follows (P2). For fine solids
and NRe,f < 0.4,

Equation 3.1-40

For large solids and NRe,f > 1000,

Equation 3.1-41

EXAMPLE 3.1-7. Expansion of Fluidized Bed

Using the data from Example 3.1-6, estimate the maximum allowable velocity  . Using an
operating velocity of 3.0 times the minimum, estimate the voidage of the bed.

S olu t ion: From Example 3.1-6, NRe,mf = 0.07764,   = 0.005029 m/s, and εmf = 0.42.


Using Eq. (3.1-40), the maximum allowable velocity is

Using an operating velocity ν' of 2.0 times the minimum,

To determine the voidage at this new velocity, we substitute into Eq. (3.1-39) using the known
values at minimum fluidizing conditions to determine K1:

Solving K1 = 0.03938. Then using the operating velocity in Eq. (3.1-39),

Solving, the voidage of the bed ε = 0.503 at the operating velocity.

5. M inimu m b u b b ling  v elocit y

The fluidization velocity at which bubbles are first observed is called the minimum bubbling velocity,

. For Group B particles, which exhibit bubbling fluidization,   is reasonably close to  . For

Group A particles,   is substantially greater than  . The following equation (G3) can be used to

calculate  :

Equation 3.1-42
where   is minimum bubbling velocity in m/s, μ is viscosity in Pa · s, and ρ is gas density in kg/m3. If

the calculated   is greater than the calculated   by Eq. (3.1-42), then the   should be used as the


minimum bubbling velocity (G4).

EXAMPLE 3.1-8. Minimum Bubbling Velocity

Using data from Example 3.1-6, calculate the  .

S olu t ion: Substituting into Eq. (3.1-42),

This is substantially greater than the   of 0.005029 m/s.
                             
                                                 
                                             
                                               
     

3.2. MEASUREMENT OF FLOW OF FLUIDS
It is important to be able to measure and control the amount of material entering and leaving a chemical
or other processing plant. Since many of the materials are in the form of fluids, they are flowing in pipes
or conduits. Many different types of devices are used to measure the flow of fluids. The simplest are those
that measure directly the volume of the fluids, such as ordinary gas and water meters and positive-
displacement pumps. Current meters make use of an element, such as a propeller or cups on a rotating
arm, which rotates at a speed determined by the velocity of the fluid passing through it. Very widely used
for fluid metering are the pitot tube, venturi meter, orifice meter, and open-channel weirs.

3.2A. Pitot Tu b e

The pitot tube is used to measure the local velocity at a given point in the flow stream and not the
average velocity in the pipe or conduit. In Fig. 3.2-1a, a sketch of this simple device is shown. One tube,
the impact tube, has its opening normal to the direction of flow, while the static tube has its opening
parallel to the direction of flow.

Figure 3.2-1. Diagram of pitot tube: (a) simple tube, (b) tube with static pressure holes.

The fluid flows into the opening at point 2; pressure builds up and then remains stationary at this point,
called the stagnation point. The difference in the stagnation pressure at point 2 and the static pressure
measured by the static tube represents the pressure rise associated with deceleration of the fluid. The
manometer measures this small pressure rise. If the fluid is incompressible, we can write the Bernoulli
equation (2.7-32) between point 1, where the velocity ν1 is undisturbed before the fluid decelerates, and
point 2, where the velocity ν2 is zero:

Equation 3.2-1
Setting ν2 = 0 and solving for ν1,

Equation 3.2-2

where ν is the velocity v1 in the tube at point 1 in m/s, p2 is the stagnation pressure, ρ is the density of the
flowing fluid at the static pressure p1, and C p is a dimensionless coefficient to take into account
deviations from Eq. (3.2-1) that generally varies between about 0.98 and 1.0. For accurate use, the
coefficient should be determined by calibration of the pitot tube. This equation applies to incompressible
fluids but can be used to approximate the flow of gases at moderate velocities and pressure changes of
about 10% or less of the total pressure. For gases the pressure change is often quite low and, hence,
accurate measurement of velocities is difficult.

The value of the pressure drop p2 - p1 or Δp in Pa is related to Δh, the reading on the manometer, by Eq.
(2.2-14) as follows:

Equation 3.2-3

where ρA is the density of the fluid in the manometer in kg/m3 and Δh is the manometer reading in m. In
Fig. 3.2-1b, a more compact design is shown with concentric tubes. In the outer tube, static pressure
holes are parallel to the direction of flow. Further details are given elsewhere (P1).

Since the pitot tube measures velocity at only one point in the flow, several methods can be used to
obtain the average velocity in the pipe. In the first method the velocity is measured at the exact center of
the tube to obtain νmax. Then by using Fig. 2.10-2, the νav  can be obtained. Care should be taken to have
the pitot tube at least 100 diameters downstream from any pipe obstruction. In the second method,
readings are taken at several known positions in the pipe cross section and then, using Eq. (2.6-17), a
graphical or numerical integration is performed to obtain νav .

EXAMPLE 3.2-1. Flow Measurement Using a Pitot Tube
A pitot tube similar to Fig. 3.2-1a is used to measure the airflow in a circular duct 600 mm in
diameter. The flowing air temperature is 65.6°C. The pitot tube is placed at the center of the
duct and the reading Δh on the manometer is 10.7 mm of water. A static-pressure
measurement obtained at the pitot tube position is 205 mm of water above atmospheric. The
pitot-tube coefficient C p = 0.98.

a.  Calculate the velocity at the center and the average velocity.
b.  Calculate the volumetric flow rate of the flowing air in the duct.

S olu t ion: For part (a), the properties of air at 65.6°C. from Appendix A.3 are μ = 2.03 × 10-5
Pa · s, ρ = 1.043 kg/m3 (at 101.325 kPa). To calculate the absolute static pressure, the
manometer reading Δh = 0.205 m of water indicates the pressure above 1 atm abs. Using Eq.
(2.2-14), the water density as 1000 kg/m3, and assuming 1.043 kg/m3 as the air density,

Then the absolute static pressure p1 = 1.01325 × 105 + 0.02008 × 105 = 1.0333 × 105 Pa. The

correct air density in the flowing air is (1.0333 × 105/1.01325 × 105)(1.043) = 1.063 kg/m3.
This correct value, when used instead of 1.043, would have a negligible effect on the
recalculation of p1.

To calculate Δp for the pitot tube, Eq. (3.2-3) is used:

Using Eq. (3.2-2), the maximum velocity at the center is

The Reynolds number, using the maximum velocity, is

From Fig. 2.10-2, νav /νmax = 0.85. Then, νav  = 0.85(13.76) = 11.70 m/s.

To calculate the flow rate for part (b), the cross-sectional area of the duct, A = (π/4)(0.600)2 =
0.2827 m2. The flow rate = 0.2827(11.70) = 3.308 m3/s.

3.2B. Ve ntu r i M e te r

A venturi meter, shown in Fig. 3.2-2, is usually inserted directly into a pipeline. A manometer or other
device is connected to the two pressure taps shown and measures the pressure difference p1 − p2 between
points 1 and 2. The average velocity at point 1 where the diameter is D1 m is ν1 m/s, and at point 2 or the
throat the velocity is ν2 and the diameter D2. Since the narrowing down from D1 to D2 and the expansion
from D2 back to D1 is gradual, little frictional loss due to contraction and expansion is incurred.
Figure 3.2-2. Venturi flow meter.

To derive the equation for the venturi meter, friction is neglected and the pipe is assumed horizontal.
Assuming turbulent flow and writing the mechanical-energy-balance equation (2.7-28) between points 1
and 2 for an incompressible fluid,

Equation 3.2-4

The continuity equation for constant p is

Equation 3.2-5

Combining Eqs. (3.2-4) and (3.2-5) and eliminating ν1,

Equation 3.2-6

To account for the small friction loss, an experimental coefficient C ν  is introduced to give

Equation 3.2-7
This holds for liquids and very small pressure drops in gases of less than 1%. For many meters and a
Reynolds number >104 at point 1, C ν  is about 0.98 for pipe diameters below 0.2 m and 0.99 for larger
sizes. However, these coefficients can vary, and individual calibration is recommended if the
manufacturer's calibration is not available.

To calculate the volumetric flow rate, the velocity ν2 is multiplied by the area A2:

Equation 3.2-8

For the measurement of compressible flow of gases, the adiabatic expansion from p1 to p2 pressure must
be allowed for in Eq. (3.2-7). A similar equation and the same coefficient C ν  are used along with the
dimensionless expansion correction factor Y (shown in Fig. 3.2-3 for air) as follows:

Equation 3.2-9

Figure 3.2-3. Expansion factor for air in venturi, flow nozzle, and orifice. [Calculated from equations and data
in references (A2, M2, S3).]

where m is flow rate in kg/s, ρ1 is density of the fluid upstream at point 1 in kg/m3, and A2 is cross-

sectional area at point 2 in m2.

The pressure difference p1 − p2 occurs because the velocity is increased from ν1 to ν2. However, farther
down the tube the velocity returns to its original value of ν1 for liquids. Because of frictional losses, some
of the difference p1 − p2 is not fully recovered downstream to the original p1. In a properly designed
venturi meter, the permanent loss is about 10% of the differential p1 − p2, and this represents power loss.
A venturi meter is often used to measure flows in large lines, such as city water systems.

3.2C . Or ifice  M e te r

For ordinary installations in a process plant the venturi meter has several disadvantages. It occupies a
lot of space and is expensive. Also, the throat diameter is fixed, so that if the flow-rate range is changed
considerably, inaccurate pressure differences may result. The orifice meter overcomes these objections
but at the price of a much larger permanent head or power loss.

A typical sharp-edged orifice is shown in Fig. 3.2-4. A machined and drilled plate having a hole of
diameter D0 is mounted between two flanges in a pipe of diameter D1. Pressure taps at points 1 upstream
and 2 downstream measure p1 − p2. The exact positions of the two taps are somewhat arbitrary: in one
type of meter the taps are installed about 1 pipe diameter upstream and 0.3 to 0.8 pipe diameter
downstream. The fluid stream, once past the orifice plate, forms a vena contracta or free-flowing jet.

Figure 3.2-4. Orifice flow meter.

The equation for the orifice is similar to Eq. (3.2-7):

Equation 3.2-10

where ν0 is the velocity in the orifice in m/s, D0 is the orifice diameter in m, and C 0 is the dimensionless
orifice coefficient. The orifice coefficient C 0 is always determined experimentally. If the NRe at the orifice
is above 20000 and D0/D1 is less than about 0.5, the value of C 0 is approximately constant and has the
value 0.61, which is adequate for design for liquids or gases (M2, P1). Below 20000 the coefficient rises
sharply and then drops, and a correlation for C 0 is given elsewhere (P1).
As in the case of the venturi, for the measurement of compressible flow of gases in an orifice, a correction
factor Y given in Fig. 3.2-3 for air is used as follows:

Equation 3.2-11

where m is flow rate in kg/s, ρ1 is upstream density in kg/m3, and A0 is the cross-sectional area of the
orifice. For liquids, Y is 1.0.

The permanent pressure loss is much higher than for a venturi because of the eddies formed when the jet
expands below the vena contracta. This loss depends on D0/D1 and is as follows:

Equation 3.2-12

where β = D0/D1 (P1) and p4 is the fully recovered pressure 4 -8 pipe diameters downstream. For β =  ,
this power loss is 75% of p1 - p2.

EXAMPLE 3.2-2. Metering Oil Flow by an Orifice
A sharp-edged orifice having a diameter of 0.0566 m is installed in a 0.1541-m pipe through
which oil having a density of 878 kg/m3 and a viscosity of 4.1 cp is flowing. The measured
pressure difference across the orifice is 93.2 kN/m2. Calculate the volumetric flow rate in m3/s.
Assume that C 0 = 0.61.

S olu t ion:

Substituting into Eq. (3.2-10).
The NRe is calculated see if it is greater than 2 × 104 for C 0 = 0.61:

Hence, the Reynolds number is above 2 × 104.

3.2D. Flow -Nozzle  M e te r

A typical flow nozzle is shown in Fig. 3.2-5. It is essentially a short cylinder with the approach being
elliptical in shape. This meter has characteristics similar to those of the venturi meter but is shorter and
much less expensive. The length of the straight portion of the throat is about one-half the diameter of the
throat, D2. The upstream pressure tap p1 is 1 pipe diameter from the inlet-nozzle face, and the

downstream tap p2 is   pipe diameter from the inlet-nozzle face.

Figure 3.2-5. Flow-nozzle meter.
The equation for flow for liquids is the same as Eq. (3.2-7) for the venturi, with the coefficient C n  for the
flow nozzle replacing C v  for the venturi. Also, the equation for compressible flow of gases for the flow
nozzle is the same as Eq. (3.2-9) for the venturi, with the coefficient C n . The expansion factor Y is the
same for the flow nozzle and the venturi.

For the flow nozzle the coefficient C n  ranges from 0.95 at a pipe Reynolds number of 104, 0.98 at 105, and

0.99 at 106 or above (P1, S3). The permanent pressure loss (p1 − p4) is as follows, where p4 is the final,
fully recovered downstream pressure:

Equation 3.2-13

where β = D2/D1. This loss is greater than that for venturi meters and less than that for orifice meters. For

β =  , this power loss is 60% of p1 − p2.

3.2E. Var iab le -Ar e a Flow  M e te r s (R otam e te r s)

In Fig. 3.2-6 a variable-area flow meter is shown. The fluid enters at the bottom of the tapered glass tube,
flows through the annular area around the tube, and exits at the top. The float remains stationary. The
differential head or pressure drop is held constant. At a higher flow rate the float rises and the annular
area increases to keep a constant pressure drop. The height of rise in the tube is calibrated with the flow
rate, and the relation between the meter reading and the flow rate is approximately linear.

Figure 3.2-6. Rotameter: (a) flow diagram with glass tube, (b) spherical float, (c) viscosity-insensitive float.

For a given float of density pf and a fluid density ρA, the mass flow rate mA is given by
Equation 3.2-14

where qA, volumetric flow rate, is the reading on the rotameter, and K is a constant which is determined
experimentally. If a fluid ρB is used instead of ρA, at the same height or reading of qA on the rotameter
and assuming K does not vary appreciably, the following approximation can be used:

Equation 3.2-15

For gases where ρf ≫ ρA and ρB,   Note that the reading on the rotameter is taken at
the highest and widest point of the float.

3.2F. Othe r  Typ e s of Flow  M e te r s

Many other types of flow meters are available; the more important ones are discussed briefly as follows:

1. Tu r b ine- a nd  p a d d le-w heel met er s

A turbine wheel or a paddle wheel is placed inside a pipe, and the rotary speed depends on the flow rate
of the fluid. Residential and industrial gas and water meters are often of the rotary wheel type.

2. Ther ma l-g a s ma ss flow  met er s

Gas flowing in a tube is divided into a constant ratio because of laminar flow into a main stream and a
small stream in a sensor tube. A small but constant amount of heat is added to the sensor tube flow. By
measuring the temperature rise, the output temperature rise can be related to the gas mass flow rate.
These meters are mass flow meters and are unaffected by temperature and pressure.

3. M a g net ic flow  met er s

A magnetic field is generated across the conductive fluid flowing in a pipe. Using Faraday's law of
electromagnetic inductance, the induced voltage is directly proportional to the flow velocity (D3). The
meter is insensitive to changes in density and viscosity. The meter cannot be used with most
hydrocarbons because of their low conductivity.

4 . C or iolis ma ss flow  met er

This meter is insensitive to operating conditions of viscosity, density, type of fluid, and slurries. Fluid
from the main flow enters two U-tube side channels (D3). The fluid induces a Coriolis force according to
Newton's second law. The tubes then twist slightly, and the measured twist angle is proportional to the
mass flow rate.
5. Vor t ex-shed d ing  flow  met er

When a fluid flows past a blunt object, the fluid forms vortices or eddies (D3). The vortices are counted
and the signal is proportional to the flow rate.

3.2G . Flow  in Op e n C hanne ls and  W e ir s

In many instances in process engineering and in agriculture, liquids are flowing in open channels rather
than closed conduits. To measure the flow rates, weir devices are often used. A weir is a dam over which
the liquid flows. The two main types of weirs are the rectangular weir and the triangular weir shown in
Fig. 3.2-7. The liquid flows over the weir, and the height h0 (weir head) in m is measured above the flat
base or the notch as shown. This head should be measured at a distance of about 3h0 m upstream of the
weir by a level or float gage.

Figure 3.2-7. Types of weirs: (a) rectangular, (b) triangular.

The equation for the volumetric flow rate q in m3 /s for a rectangular weir is given by

Equation 3.2-16

where L = crest length in m, g = 9.80665 m/s2, and h0 = weir head in m. This is called the modified
Francis weir formula and it agrees with experimental values within 3% if L > 2h0, velocity upstream <
0.6 m/s, h0 > 0.09 m, and the height of the crest above the bottom of the channel > 3h0. In English units

L and h are in ft, q in ft 3/s, and g = 32.174 ft/s2.

For the triangular notch weir,

Equation 3.2-17

Both Eqs. (3.2-16) and (3.2-17) apply only to water. For other liquids, see data given elsewhere (P1).
                             
                                                 
                                             
                                               
     

3.3. PUMPS AND GAS­MOVING EQUIPMENT

3.3A. Intr od u ction

In order to make a fluid flow from one point to another in a closed conduit or pipe, it is necessary to have
a driving force. Sometimes this force is supplied by gravity, where differences in elevation occur. Usually,
the energy or driving force is supplied by a mechanical device such as a pump or blower, which increases
the mechanical energy of the fluid. This energy may be used to increase the velocity (move the fluid), the
pressure, or the elevation of the fluid, as seen in the mechanical-energy-balance equation (2.7-28), which
relates ν, p, ρ, and work. The most common methods of adding energy are by positive displacement or
centrifugal action.

Generally, the word "pump" designates a machine or device for moving an incompressible liquid. Fans,
blowers, and compressors are devices for moving gas (usually air). Fans discharge large volumes of gas at
low pressures on the order of several hundred mm of water. Blowers and compressors discharge gases at
higher pressures. In pumps and fans the density of the fluid does not change appreciably, and
incompressible flow can be assumed. Compressible flow theory is used for blowers and compressors.

3.3B. Pu m p s

1. Pow er  a nd  w or k  r eq u ir ed

Using the total mechanical-energy-balance equation (2.7-28) on a pump and piping system, the actual
or theoretical mechanical energy WS J/kg added to the fluid by the pump can be calculated. Example 2.7-
5 shows such a case. If η is the fractional efficiency and Wp the shaft work delivered to the pump, Eq.
(2.7-30) gives

Equation 3.3-1

The actual or brake power of a pump is as follows:

Equation 3.3-2

where Wp is J/kg, m is the flow rate in kg/s, and 1000 is the conversion factor W/kW. In English units,
WS is in ft · lbf/lbm and m in lbm/s. The theoretical or fluid power is

Equation 3.3-3

The mechanical energy WS in J/kg added to the fluid is often expressed as the developed head H of the
pump in m of fluid being pumped, where

Equation 3.3-4

To calculate the power of a fan where the pressure difference is on the order of a few hundred mm of
water, a linear average density of the gas between the inlet and outlet of the fan is used to calculate WS
and brake kW or horsepower.

2. Elect r ic mot or  efficiency

Since most pumps are driven by electric motors, the efficiency of the electric motor must be taken into
account to determine the total electric power to the motor. Typical efficiencies ηe of electric motors are as

follows: 77% for  -kW motors, 82% for 2 kW, 85% for 5 kW, 88% for 20 kW, 90% for 50 kW, 91% for 100
kW, and 93% for 500 kW and larger. Hence, the total electric power input equals the brake power divided
by the electric motor drive efficiency ηe:

Equation 3.3-5

3. S u ct ion lift  of p u mp s (NPS H)

The power calculated by Eq. (3.3-4) depends on the differences in pressures and not on the actual
pressures being above or below atmospheric pressure. However, the lower limit of the absolute pressure in
the suction (inlet) line to the pump is fixed by the vapor pressure of the liquid at the temperature of the
liquid in the suction line. If the pressure on the liquid in the suction line drops below the vapor pressure,
some of the liquid flashes into vapor (cavitation). Then no liquid can be drawn into the pump, and
vibration can occur.

To avoid flashes of vapor or cavitation, the pressure at the inlet of the pump must be greater than this
vapor pressure and exceed it by a value termed the net positive suction head required, or (NPSH)R.
Pump manufacturers measure these values experimentally and include them with the pumps furnished.
For water below 100°C at 1750 rpm and centrifugal pumps, typical values of (NPSH)R are as follows
(P4): For pressures 3500 kPa (500 psig) or below: up to 200 gpm, 1.5 m (5 ft); 500 gpm, 2.1 m (7 ft); 1000
gpm, 3 m (10 ft); 2000 gpm, 5.5 m (18 ft). At pressures of 7000 kPa (1000 psig) the values are doubled at
200 gpm or less and at 2000 gpm increased by 20%. At an rpm of 3550, the (NPSH)R increases by about
a factor of 2.2.

To calculate the net positive suction head that will be available (NPSH)A at the pump suction for the
system shown in Fig. 3.3-1, Eq. (3.3-6) can be used:

Equation 3.3-6

Figure 3.3-1. Diagram for (NPSH)A available in a pumping system.

where (NPSH)A is in m (ft), ρ is density of liquid in kg/m3 (lbm/ft 3), p1 is pressure above liquid surface in

N/m2 (lbf/ft 2), pvp is vapor pressure of fluid at the given temperature in N/m2 (lbf/ft 2), z1 is height of


open surface of liquid above pump centerline in m (ft), ΣF is friction loss in suction line to pump from Eq.
(2.10-18) in J/kg (ft lbf/lbm), and ν2/2 is velocity head in J/kg (ν2/2g c is ft lbf/lbm). Note that in Eq. (3.3-
6) for SI units, the (NPSH)A in m is multiplied by g to give J/kg.

For cold water and the case where all the terms in Eq. (3.3-6) are small except p1, at atmospheric
pressure the (NPSH)A is 10.3 m (33.9 ft). However, a practical limit is about 7.5 m (24.6 ft). The available
NPSH for a given pump should be at least 1 m (3 ft) more than that required by the manufacturer.

EXAMPLE 3.3-1. (NPSH)A  Available for Pump
Water at 50°C is in an open tank at atmospheric pressure. The pump is 3.0 m above the open
tank level. The velocity in the pipe is 0.9 m/s. The friction head loss in the pipe has been
calculated as 1.0 m. The required (NPSH)R for this pump is 2.0 m. Calculate the available
(NPSH)A.

S olu t ion: From Appendix A.2-3, ρ = 988.07 kg/m3. Also, the vapor pressure pvp = 12.349

kPa from A.2-9 and p1 = 1.01325 × 105 Pa. Substituting into Eq. (3.3-6) and noting that z1 is
negative and that the friction loss head of 1.0 m is multiplied by g,

Solving, (NPSH)A = 5.14m

Hence, the available (NPSH)A of 5.14 m is sufficiently greater than that required of 2.0 m.

4 . C ent r ifu g a l p u mp s

Process industries commonly use centrifugal pumps. They are available in sizes of about 0.004 to 380
m3/min (1 to 100000 gal/min) and for discharge pressures from a few m of head to 5000 kPa or so. A
centrifugal pump in its simplest form consists of an impeller rotating inside a casing. Figure 3.3-2 shows
a schematic diagram of a simple centrifugal pump.

Figure 3.3-2. Simple centrifugal pump.

The liquid enters the pump axially at point 1 in the suction line and then enters the rotating eye of the
impeller, where it spreads out radially. On spreading radially it enters the channels between the vanes at
point 2 and flows through these channels to point 3 at the periphery of the impeller. From here it is
collected in the volute chamber 4 and flows out the pump discharge at 5. The rotation of the impeller
imparts a high-velocity head to the fluid, which is changed to a pressure head as the liquid passes into
the volute chamber and out the discharge. Some pumps are also made as two-stage or even multistage
pumps.

Many complicating factors determine the actual efficiency and performance characteristics of a pump.
Hence, the actual experimental performance of the pump is usually employed. The performance is
usually expressed by the pump manufacturer in terms of curves called characteristic curves, which are
usually for water. The head H in m produced will be the same for any liquid of the same viscosity. The
pressure produced, p = Hρ g, will be in proportion to the density. Viscosities of less than 0.05 Pa · s (50
cp) have little effect on the head produced. The brake kW varies directly as the density.

Pump efficiencies typical of centrifugal pumps at rated capacities are as follows: 50% for 0.075 m 3 /min
(20 gal/min), 62% for 0.19 m3/min (50 gal/min), 68% for 0.38 m3/min (100 gal/min), 75% for 0.76 m3
/min (200 gal/min), 82% for 1.89 m3/min (500 gal/min), and 85% for 3.8 m3/min (1000 gal/min).

As rough approximations, the following relationships, called affinity laws, can be used for a given pump.
The capacity q1 in m3/s is directly proportional to the rpm N1 or

Equation 3.3-7

The head H1 is proportional to   or

Equation 3.3-8

The power consumed W1 is proportional to the product of H1q1, or

Equation 3.3-9

A given pump can be modified when needed for a different capacity by changing the impeller size. Then
the affinity laws for a constant-rpm N are as follows: The capacity q is proportional to the diameter D,
the head H is proportional to D2, and the brake horsepower W is proportional to D3.

In most pumps, the speed is generally not varied. Characteristic curves for a typical single-stage
centrifugal pump operating at a constant speed are given in Fig. 3.3-3 Most pumps are usually rated on
the basis of head and capacity at the point of peak efficiency. The efficiency reaches a peak at about 50
gal/min flow rate. As the discharge rate in gal/min increases, the developed head drops. The brake hp
increases, as expected, with flow rate.
Figure 3.3-3. Characteristic curves for a single-stage centrifugal pump with water. (From W. L. Badger and J.
T. Banchero, Introduction to Chemical Engineering. New York: McGraw-Hill Book Company, 1955. With
permission.)

EXAMPLE 3.3-2. Calculation of Brake Horsepower of a
Pump
In order to see how the brake-hp curve is determined, calculate the brake hp at 40 gal/min flow
rate for the pump in Fig. 3.3-3.

S olu t ion: At 40 gal/min, the efficiency η from the curve is about 60% and the head H is 38.5
ft. A flow rate of 40 gal/min of water with a density of 62.4 lb mass/ft 3 is

The work WS is as follows, from Eq. (3.3-4):

The brake hp from Eq. (3.3-2) is

This value agrees with the value on the curve in Fig. 3.3-3.
5. Posit iv e-d isp la cement  p u mp s

In this class of pumps, a definite volume of liquid is drawn into a chamber and then forced out of the
chamber at a higher pressure. There are two main types of positive-displacement pumps. In the
reciprocating pump the chamber is a stationary cylinder, and liquid is drawn into the cylinder by
withdrawal of a piston in the cylinder. Then the liquid is forced out by the piston on the return stroke. In
the rotary pump the chamber moves from inlet to discharge and back again. In a gear rotary pump two
intermeshing gears rotate, and liquid is trapped in the spaces between the teeth and forced out the
discharge.

Reciprocating and rotary pumps can be used to very high pressures, whereas centrifugal pumps are
limited in their head and are used for lower pressures. Centrifugal pumps deliver liquid at uniform
pressure without shocks or pulsations and can handle liquids with large amounts of suspended solids. In
general, in chemical and biological processing plants, centrifugal pumps are primarily used.

Equations (3.3-1) through (3.3-5) hold for calculation of the power of positive-displacement pumps. At a
constant speed, the flow capacity will remain constant with different liquids. In general, the discharge
rate will be directly dependent upon the speed. The power increases directly as the head, and the
discharge rate remains nearly constant as the head increases.

Pump efficiencies η of reciprocating pumps used to calculate brake horsepower are as follows: 55% at 2.2
kW (3 hp), 70% at 7.5 kW (10 hp), 77% at 14.9 kW (20 hp), 85% at 37 kW (50 hp), and 90% at 373 kW
(500 hp).

3.3C . G as-M ov ing M achine r y

Gas-moving machinery comprises mechanical devices used for compressing and moving gases. They are
often classified or considered from the standpoint of the pressure heads produced and include fans for
low pressures, blowers for intermediate pressures, and compressors for high pressures.

1. Fa ns

The commonest method for moving small volumes of gas at low pressures is by means of a fan. Large
fans are usually centrifugal and their operating principle is similar to that of centrifugal pumps. The
discharge heads are low, from about 0.1 m to 1.5 m H2O. However, in some cases much of the added
energy of the fan is converted to velocity energy and a small amount to pressure head.

In a centrifugal fan, the centrifugal force produced by the rotor causes a compression of the gas, called the
static pressure head. Also, since the velocity of the gas is increased, a velocity head is produced. Both the
static-pressure-head increase and velocity-head increase must be included in estimating efficiency and
power. Operating efficiencies are in the range 40–70%. The operating pressure of a fan is generally given
as inches of water gage and is the sum of the velocity head and the static pressure of the gas leaving the
fan. Incompressible flow theory can be used to calculate the power of fans.

When the rpm or speed of centrifugal fans varies, the performance equations are similar to Eqs. (3.3-7)-
(3.3-9) for centrifugal pumps.

EXAMPLE 3.3-3. Brake-kW Power of a Centrifugal Fan
It is desired to use 28.32 m3/min of air (metered at a pressure of 101.3 kPa and 294.1 K) in a
process. This amount of air, which is at rest, enters the fan suction at a pressure of 741.7 mm
Hg and a temperature of 366.3 K and is discharged at a pressure of 769.6 mm Hg and a
velocity of 45.7 m/s. A centrifugal fan having a fan efficiency of 60% is to be used. Calculate
the brake-kW power needed.

S olu t ion: Incompressible flow can be assumed, since the pressure drop is only
(27.9/741.7)100, or 3.8% of the upstream pressure. The average density of the flowing gas can
be used in the mechanical-energy-balance equation.

The density at the suction, point 1, is

(The molecular weight of 28.97 for air, the volume of 22.414 m3/kg mol at 101.3 kPa, and 273.2
K were obtained from Appendix A.1.) The density at the discharge, point 2, is

The average density of the gas is

The mass flow rate of the gas is

The developed pressure head is

The developed velocity head for ν1 = 0 is
Writing the mechanical-energy-balance equation (2.7-28),

Setting z1 = 0, z2 = 0, v1 = 0, and Σ F = 0, and solving for WS,

Substituting into Eq. (3.3-2),

2. Blow er s a nd  comp r essor s

For handling gas volumes at higher pressure rises than fans, several distinct types of equipment are
used. Turboblowers or centrifugal compressors are widely used to move large volumes of gas for
pressure rises from about 5 kPa to several thousand kPa. The principles of operation for a turboblower are
the same as for a centrifugal pump. The turboblower resembles the centrifugal pump in appearance, the
main difference being that the gas in the blower is compressible. The head of the turboblower, as in a
centrifugal pump, is independent of the fluid handled. Multistage turboblowers are often used to go to
the higher pressures.

Rotary blowers and compressors are machines of the positive-displacement type and are essentially
constant-volume flow-rate machines with variable discharge pressure. Changing the speed will change
the volume flow rate. Details of construction of the various types (P1) vary considerably, and pressures
up to about 1000 kPa can be obtained, depending on the type.

Reciprocating compressers which are of the positive displacement type using pistons are available for
higher pressures. Multistage machines are also available for pressures up to 10 000 kPa or more.

3.3D. Eq u ations for  C om p r e ssion of G ase s

In blowers and compressors, pressure changes are large and compressible flow occurs. Since the density
changes markedly, the mechanical-energy-balance equation must be written in differential form and then
integrated to obtain the work of compression. In compression of gases the static-head terms, velocity-
head terms, and friction terms are dropped and only the work term dW and the dp/ρ term remain in the
differential form of the mechanical-energy equation; or,

Equation 3.3-10
Integration between the suction pressure p1 and discharge pressure p2 gives the work of compression:

Equation 3.3-11

1. Isot her ma l comp r ession

To integrate Eq. (3.3-11) for a perfect gas, either isothermal or adiabatic compression is assumed. For
isothermal compression, where the gas is cooled on compression, p/ρ is a constant equal to RT/M, where
R = 8314.3 J/kg mol · K in SI units and 1545.3 ft · lbf/lb mol · °R in English units. Then,

Equation 3.3-12

Solving for ρ in Eq. (3.3-12) and substituting it in Eq. (3.3-11), the work for isothermal compression is

Equation 3.3-13

Also, T1 = T2, since the process is isothermal.

2. Ad ia b a t ic comp r ession

For adiabatic compression, the fluid follows an isentropic path and

Equation 3.3-14

where γ = cp/cν , the ratio of heat capacities. By combining Eqs. (3.3-11) and (3.3-14) and integrating,

Equation 3.3-15
The adiabatic temperatures are related by

Equation 3.3-16

To calculate the brake power when the efficiency is η,

Equation 3.3-17

where m = kg gas/s and WS = J/kg.

The values of γ are approximately 1.40 for air, 1.31 for methane, 1.29 for SO2, 1.20 for ethane, and 1.40 for
N2 (P1). For a given compression ratio, the work for isothermal compression in Eq. (3.3-13) is less than
the work for adiabatic compression in Eq. (3.3-15). Hence, cooling is sometimes used in compressors.

EXAMPLE 3.3-4. Compression of Methane
A single-stage compressor is to compress 7.56 × 10-3 kg mol/s of methane gas at 26.7°C and
137.9 kPa abs to 551.6 kPa abs.

a.  Calculate the power required if the mechanical efficiency is 80% and the compression is
adiabatic.

b.  Repeat, but for isothermal compression.

S olu t ion: For part (a), p1 = 137.9 kPa, p2 = 551.6 kPa, M = 16.0 kg mass/kg mol, and T1 =
273.2 + 26.7 = 299.9 K. The mass flow rate per sec is

Substituting into Eq. (3.3-15) for γ = 1.31 for methane and p2/p1 = 551.6/137.9 = 4.0/1,
Using Eq. (3.3-17),

For part (b), using Eq. (3.3-13) for isothermal compression,

Hence, isothermal compression uses 15.8% less power.

3. Poly t r op ic comp r ession

In large compressors neither isothermal nor adiabatic compression is achieved. This polytropic path is

Equation 3.3-18

For isothermal compression n = 1.0 and for adiabatic, n = γ. The value of n is found by measuring the
pressure p1 and density ρ1 at the inlet and p2 and ρ2 at the discharge and substituting these values into
Eq. (3.3-18).

4 . M u lt ist a g e comp r ession r a t ios

Water cooling is used between each stage in multistage compressors to reduce the outlet temperature to
near the inlet temperature for minimum power requirement. The compression ratios should be the same
for each stage so that the total power is a minimum. This gives the same power in each stage. Hence, for
n stages, the compression ratio (pb/pa ) for each stage is

Equation 3.3-19

where p1 is the inlet pressure and pn  the outlet pressure from n stages. For two stages, the compression
ratio is  .
                             
                                                 
                                             
                                               
     

3.4. AGITATION AND MIXING OF FLUIDS AND POWER
REQUIREMENTS

3.4 A. Pu r p ose s of Agitation

In the chemical and other processing industries, many operations are dependent to a great extent on
effective agitation and mixing of fluids. Generally, agitation refers to forcing a fluid by mechanical
means to flow in a circulatory or other pattern inside a vessel. Mixing usually implies the taking of two or
more separate phases, such as a fluid and a powdered solid or two fluids, and causing them to be
randomly distributed through one another.

There are a number of purposes for agitating fluids, some of which are briefly summarized:

1.  Blending of two miscible liquids, such as ethyl alcohol and water.

2.  Dissolving solids in liquids, such as salt in water.

3.  Dispersing a gas in a liquid as fine bubbles, such as oxygen from air in a suspension of
microorganisms for fermentation or for the activated sludge process in waste treatment.

4.  Suspending of fine solid particles in a liquid, as in the catalytic hydrogenation of a liquid, where
solid catalyst particles and hydrogen bubbles are dispersed in the liquid.

5.  Agitation of the fluid to increase heat transfer between the fluid and a coil or jacket in the vessel
wall.

3.4 B. Eq u ip m e nt for  Agitation

Generally, liquids are agitated in a cylindrical vessel which can be closed or open to the air. The height of
liquid is approximately equal to the tank diameter. An impeller mounted on a shaft is driven by an
electric motor. A typical agitator assembly is shown in Fig. 3.4-1.

Figure 3.4-1. Baffl ed tank and three-blade propeller agitator with axial-flow patte rn: (a) side view, (b) botto m


view.
1. Thr ee-b la d e p r op eller  a g it a t or

There are several types of agitators that are widely used. A common type, shown in Fig. 3.4-1, is a three-
bladed marine-type propeller similar to the propeller blade used in driving boats. The propeller can be a
side-entering type in a tank or be clamped on the side of an open vessel in an off-center position. These
propellers turn at high speeds of 400 to 1750 rpm (revolutions per minute) and are used for liquids of low
viscosity. The flow pattern in a baffled tank with a propeller positioned on the center of the tank is shown
in Fig. 3.4-1. This type of flow pattern is called axial flow since the fluid flows axially down the center
axis or propeller shaft and up on the sides of the tank as shown.

2. Pa d d le a g it a t or s

Various types of paddle agitators are often used at low speeds, between about 20 and 200 rpm. Two-
bladed and four-bladed flat paddles are often used, as shown in Fig. 3.4-2a. The total length of the

paddle impeller is usually 60–80% of the tank diameter and the width of the blade   to   of its length.


At low speeds mild agitation is obtained in an unbaffled vessel. At higher speeds baffles are used, since,
without baffles, the liquid is simply swirled around with little actual mixing. The paddle agitator is
ineffective for suspending solids, since good radial flow is present but little vertical or axial flow. An
anchor or gate paddle, shown in Fig. 3.4-2b, is often used. It sweeps or scrapes the tank walls and
sometimes the tank bottom. It is used with viscous liquids where deposits on walls can occur and to
improve heat transfer to the walls. However, it is a poor mixer. Paddle agitators are often used to process
starch pastes, paints, adhesives, and cosmetics.

Figure 3.4-2. Various types of agitators: (a) four-blade paddle, (b) gate or anchor paddle, (c) six-blade open
turbine, (d) pitched-blade (45°) turbine.
3. Tu r b ine a g it a t or s

Turbines that resemble multibladed paddle agitators with shorter blades are used at high speeds for
liquids with a very wide range of viscosities. The diameter of a turbine is normally between 30 and 50% of
the tank diameter. The turbines usually have four or six blades. Figure 3.4-3 shows a flat six-blade
turbine agitator with disk. In Fig. 3.4-2c a flat six-blade open turbine is shown. The turbines with flat
blades give radial flow, as shown in Fig. 3.4-3. They are also useful for good gas dispersion; the gas is
introduced just below the impeller at its axis and is drawn up to the blades and chopped into fine
bubbles. In the pitched-blade turbine shown in Fig. 3.4-2d, with the blades at 45°, some axial flow is
imparted so that a combination of axial and radial flow is present. This type is useful in suspending
solids since the currents flow downward and then sweep up the solids.

Figure 3.4-3. Baffled tank with six-blade turbine agitator with disk showing flow patterns: (a) side view, (b)
bottom view, (c) dimensions of turbine and tank.

Often a pitched-blade turbine with only four blades is used in suspension of solids. A high-efficiency,
three-blade impeller (B6, F2) shown in Fig. 3.4-4a is similar to a four-blade pitched turbine; however, it
features a larger pitch angle of 30–60° at the hub and a smaller angle of 10–30° at the tip. This axial-
flow impeller produces more fluid motion and mixing per unit of power and is very useful in suspension
of solids.

Figure 3.4-4. Other types of agitators: (a) high-efficiency, three-blade impeller, (b) double-helical-ribbon, (c)
helical-screw. [Reprinted with permission from André Bakker and Lewis E. Gates, Chem. Eng. Progr., 91
(Dec.), 25 (1995). Copyright by the American Institute of Chemical Engineers.]

4 . Helica l-r ib b on a g it a t or s

This type of agitator is used in highly viscous solutions and operates at a low RPM in the laminar region.
The ribbon is formed in a helical path and is attached to a central shaft. The liquid moves in a tortuous
flow path down the center and up along the sides in a twisting motion. Similar types are the double-
helical-ribbon agitator shown in Fig. 3.4-4b and the helical-screw impeller shown in Fig. 3.4-4c.

5. Ag it a t or  select ion a nd  v iscosit y  r a ng es

The viscosity of the fluid is one of several factors affecting the selection of the type of agitator. Indications
of the viscosity ranges of these agitators are as follows. Propellers are used for fluid viscosities below
about 3 Pa · s (3000 cp); turbines can be used below about 100 Pa · s (100 000 cp); modified paddles such
as anchor agitators can be used above 50 Pa · s to about 500 Pa · s (500 000 cp); helical and ribbon-type
agitators are often used above this range to about 1000 Pa · s and have been used up to 25 000 Pa · s. For
viscosities greater than about 2.5 to 5 Pa · s (5000 cp) and above, baffles are not needed since little
swirling is present above these viscosities.

3.4 C . Flow  Patte r ns in Agitation

The flow patterns in an agitated tank depend upon the fluid properties, the geometry of the tank, the
types of baffles in the tank, and the agitator itself. If a propeller or other agitator is mounted vertically in
the center of a tank with no baffles, a swirling flow pattern usually develops. Generally, this is
undesirable, because of excessive air entrainment, development of a large vortex, surging, and the like,
especially at high speeds. To prevent this, an angular off-center position can be used with propellors with
small horsepower. However, for vigorous agitation at higher power, unbalanced forces can become severe
and limit the use of higher power.

For vigorous agitation with vertical agitators, baffles are generally used to reduce swirling and still
promote good mixing. Baffles installed vertically on the walls of the tank are shown in Fig. 3.4-3. Usually
four baffles are sufficient, with their width being about   of the tank diameter for turbines and
propellers. The turbine impeller drives the liquid radially against the wall, where it divides with one
portion flowing upward near the surface and back to the impeller from above and the other flowing
downward. Sometimes, in tanks with large liquid depths much greater than the tank diameter, two or
three impellers are mounted on the same shaft, each acting as a separate mixer. The bottom impeller is
about 1.0 impeller diameter above the tank bottom.

In an agitation system, the volume flow rate of fluid moved by the impeller, or circulation rate, is
important in sweeping out the whole volume of the mixer in a reasonable time. Also, turbulence in the
moving stream is important for mixing, since it entrains the material from the bulk liquid in the tank
into the flowing stream. Some agitation systems require high turbulence with low circulation rates,
others low turbulence with high circulation rates. This often depends on the types of fluids being mixed
and on the amount of mixing needed.

3.4 D. Typ ical " S tand ar d "  De sign of Tu r b ine

The turbine agitator shown in Fig. 3.4-3 is the most commonly used agitator in the process industries.
For design of an ordinary agitation system, this type of agitator is often used in the initial design. The
geometric proportions of the agitation system which are considered as a typical "standard" design are
given in Table 3.4-1. These relative proportions are the basis for the major correlations of agitator
performance in numerous publications. (See Fig. 3.4-3c for nomenclature.)

Table 3.4-1. Geometric Proportions for a " Standard"  Agitation System

In some cases W/Da  =   for agitator correlations. The number of baffles is four in most uses. The


clearance or gap between the baffles and the wall is usually 0.10–0.15 J to ensure that liquid does not
form stagnant pockets next to the baffle and wall. In a few correlations the ratio of baffle to tank diameter

is J/Dt =   instead of  .

3.4 E. Pow e r  Use d  in Agitate d  Ve sse ls

In the design of an agitated vessel, an important factor is the power required to drive the impeller. Since
the power required for a given system cannot be predicted theoretically, empirical correlations have been
developed to predict the power required. The presence or absence of turbulence can be correlated with the

impeller Reynolds number  , defined as
Equation 3.4-1

where Da  is the impeller (agitator) diameter in m, N is rotational speed in rev/s, ρ is fluid density in

kg/m3, and μ is viscosity in kg/m · s. The flow is laminar in the tank for   < 10, turbulent for   >


104, and for a range between 10 and 104, the flow is transitional, being turbulent at the impeller and
laminar in remote parts of the vessel.

Power consumption is related to fluid density ρ, fluid viscosity μ, rotational speed N, and impeller

diameter Da  by plots of power number Np versus  . The power number is

Equation 3.4-2

where P = power in J/s or W. In English units, P = ft · lbf/s.

Figure 3.4-5 is a correlation (B3, R1) for frequently used impellers with Newtonian liquids contained in
baffled, cylindrical vessels. Dimensional measurements of baffle, tank, and impeller sizes are given in

Fig. 3.4-3c. These curves may also be used for the same impellers in unbaffled tanks when   is 300 or

less (B3, R1). When   is above 300, the power consumption for an unbaffled vessel is considerably less
than for a baffled vessel. Curves for other impellers are also available (B3, R1).

Figure 3.4-5. Power correlations for various impellers and baffles (see Fig. 3.4-3c for dimension Da , Dt, J, and

W).

Curve 1. Flat six-blade turbine with disk (like Fig. 3.4-3 but six blades); Da/W = 5; four baffles each Dt /J = 12. Curve 2. Flat six-blade
open turbine (like Fig. 3.4-2c); Da/W = 8; four baffles each Dt /J = 12. Curve 3. Six-blade open turbine (pitched-blade) but blades at 45°
(like Fig. 3.4-2d); Da/W = 8; four baffles each Dt /J = 12. Curve 4. Propeller (like Fig. 3.4-1); pitch = 2Da; four baffles each Dt /J = 10; also
holds for same propeller in angular off-center position with no baffles. Curve 5. Propeller; pitch = Da; four baffles each Dt /J = 10; also
holds for same propeller in angular off-center position with no baffles. Curve 6. High-efficiency impeller (like Fig. 3-4-4a); four baffles
each Dt /J = 12. [Curves 1, 2, and 3 reprinted with permission from R. L. Bates. P. L. Fondy, and R. R. Corpstein, Ind. Eng. Chem. Proc.
Des. Dev., 2, 310 (1963). Copyright by the American Chemical Society. Curves 4 and 5 from J. H. Rushton, E. W. Costich, and H. J.
Everett, Chem. Eng. Progr., 46, 395, 467 (1950). With permission.]
The power-number curve for Np for the high-efficiency, three-blade impeller is shown as curve 6 in Fig. 3-
4-5.

EXAMPLE 3.4-1. Power Consumption in an Agitator
A flat-blade turbine agitator with disk having six blades is installed in a tank similar to Fig.
3.4-3. The tank diameter Dt is 1.83 m, the turbine diameter Da  is 0.61 m, Dt = H, and the
width W is 0.122 m. The tank contains four baffles, each having a width J of 0.15 m. The
turbine is operated at 90 rpm and the liquid in the tank has a viscosity of 10 cp and a density
of 929 kg/m3.

a.  Calculate the required kW of the mixer.

b.  For the same conditions, except for the solution having a viscosity of 100 000 cp,
calculate the required kW.

S olu t ion: For part (a) the following data are given: Da  = 0.61 m, W = 0.122 m, Dt = 1.83 m, J

= 0.15 m, N = 90/60 = 1.50 rev/s, ρ = 929 kg/m3, and

Using Eq. (3.4-1), the Reynolds number is
Using curve 1 in Fig. 3.4-5, since Da /W = 5 and Dt/J = 12, NP = 5 for   = 5.185 × 104.
Solving for P in Eq. (3.4-2) and substituting known values,

For part (b),

This is in the laminar flow region. From Fig. 3.4-5, NP = 14.

Hence, a 10 000-fold increase in viscosity only increases the power from 1.324 to 3.71 kW.

Variations of various geometric ratios from the "standard" design can have different effects on the power
number NP in the turbulent region of the various turbine agitators as follows (B3):

1.  For the flat six-blade open turbine, NP ∝ (W/Da )1.0.

2.  For the flat six-blade open turbine, varying Da /Dt from 0.25 to 0.50 has practically no effect on


NP.

3.  With two six-blade open turbines installed on the same shaft and the spacing between the two
impellers (vertical distance between the bottom edges of the two turbines) being at least equal to
Da , the total power is 1.9 times a single flat-blade impeller. For two six-blade pitched-blade (45°)
turbines, the power is also about 1.9 times that of a single pitched-blade impeller.

4.  A baffled, vertical square tank or a horizontal cylindrical tank has the same power number as a
vertical cylindrical tank. However, marked changes in the flow patterns occur.

The power number for a plain anchor-type agitator similar to Fig. 3.4-2b but without the two horizontal

crossbars is as follows for   < 100 (H2):

Equation 3.4-3
where Da /Dt = 0.90, W/Dt = 0.10, and C/Dt = 0.05.

The power number for a helical-ribbon agitator for very viscous liquids for   < 20 is as follows (H2,
P3):

Equation 3.4-4

Equation 3.4-5

The typical dimensional ratios used are Da /Dt = 0.95, with some ratios as low as 0.75, and W/Dt =
0.095. The agitator pitch is the vertical distance of a single flight of the helix in a 360° rotation (B6).

3.4 F. Agitator  S cale -Up

1. Int r od u ct ion

In the process industries, experimental data are often available for a laboratory-size or pilot-unit-size
agitation system, and it is desired to scale up the results to design a full-scale unit. Since the processes to
be scaled up are very diverse, no single method can handle all types of scale-up problems, and many
approaches to scale-up exist. Geometric similarity is, of course, important and simplest to achieve.
Kinematic similarity can be defined in terms of ratios of velocities or of times (R2). Dynamic similarity
requires fixed ratios of viscous, inertial, or gravitational forces. Even if geometric similarity is achieved,
dynamic and kinematic similarity often cannot be obtained at the same time. Hence, it is frequently up
to the designer to rely on judgment and experience in the scale-up.

In many cases, the main objectives usually present in an agitation process are as follows: equal liquid
motion, such as in liquid blending, where the liquid motion or corresponding velocities are
approximately the same in both cases; equal suspension of solids, where the levels of suspension are the
same; and equal rates of mass transfer, where mass transfer is occurring between a liquid and a solid
phase, liquid-liquid phases, and so on, and the rates are the same.

2. S ca le-u p  p r oced u r e

A suggested step-by-step procedure to follow in the scale-up is detailed as follows for scaling up from the
initial conditions, where the geometric sizes given in Table 3.4-1 are Da1, DT1, H1, W1, and so on, to the
final conditions of Da2, DT2, and so on.

1.  Calculate the scale-up ratio R. Assuming that the original vessel is a standard cylinder with DT1 =
H1, the volume V1 is

Equation 3.4-6

Then the ratio of the volumes is

Equation 3.4-7

The scale-up ratio is then

Equation 3.4-8

2.  Using this value of R, apply it to all of the dimensions in Table 3.4-1 to calculate the new
dimensions. For example,

Equation 3.4-9

3.  Then a scale-up rule must be selected and applied to determine the agitator speed N2 to be used to
duplicate the small-scale results using N1. This equation is as follows (R2):

Equation 3.4-10

where n = 1 for equal liquid motion, n =   for equal suspension of solids, and n =   for equal rates


of mass transfer (which is equivalent to equal power per unit volume). This value of n is based on
empirical and theoretical considerations.

4.  Knowing N2, the power required can be determined using Eq. (3.4-2) and Fig. 3.4-5.
EXAMPLE 3.4-2. Derivation of Scale-Up Rule Exponent
For the scale-up-rule exponent n in Eq. (3.4-10), show the following for turbulent agitation:

a.  That when n =  , the power per unit volume is constant in the scale-up.

b.  That when n = 1.0, the tip speed is constant in the scale-up.

S olu t ion: For part (a), from Fig. 3.4-5, NP is constant for the turbulent region. From Eq. (3.4-
2),

Equation 3.4-11

Then for equal power per unit volume, P1/V1 = P2/V2, or, using Eq. (3.4-6),

Equation 3.4-12

Substituting Pl from Eq. (3.4-11) together with a similar equation for P2 into Eq. (3.4-12) and
combining with Eq. (3.4-8).

Equation 3.4-13

For part (b), using Eq. (3.4-10) with n = 1.0, rearranging, and multiplying by π,

Equation 3.4-14

Equation 3.4-15

where πDT2 N2 is the tip speed in m/s.

To aid the designer of new agitation systems as well as serve as a guide for evaluating existing systems,
some approximate guidelines are given as follows for liquids of normal viscosities (M2): for mild
agitation and blending, 0.1 to 0.2 kW/m3 of fluid (0.0005 to 0.001 hp/gal); for vigorous agitation, 0.4 to
0.6 kW/m3 (0.002 to 0.003 hp/gal); for intense agitation or where mass transfer is important, 0.8 to 2.0
kW/m3 (0.004 to 0.010 hp/gal). This power in kW is the actual power delivered to the fluid as given in
Fig. 3.4-5 and Eq. (3.4-2). This does not include the power used in the gear boxes and bearings. Typical
efficiencies of electric motors are given in Section 3.3B. As an approximation, the power lost in the gear
boxes and bearings and in inefficiency of the electric motor is about 30 to 40% of P, the actual power
input to the fluid.

EXAMPLE 3.4-3. Scale-Up of Turbine Agitation System
An existing agitation system is the same as given in Example 3.4-1a for a flat-blade turbine
with a disk and six blades. The given conditions and sizes are DT1 = 1.83 m, Da1 = 0.61 m, W1

= 0.122 m, J1 = 0.15 m, N1 = 90/60 = 1.50 rev/s, ρ = 929 kg/m3, and μ = 0.01 Pa · s. It is
desired to scale up these results for a vessel whose volume is 3.0 times as large. Do this for the
following two process objectives:

a.  Where equal rate of mass transfer is desired.

b.  Where equal liquid motion is needed.

S olu t ion: Since H1 = DT1 = 1.83 m, the original tank volume V1 = (π /4)(H1) = π(1.83)3/4

= 4.813 m3. Volume V2 = 3.0(4.813) = 14.44 m3. Following the steps in the scale-up
procedure, and using Eq. (3.4-8),

The dimensions of the larger agitation system are as follows: DT
2  = R D T 1 = 1.4 4 2(1.83) = 2.6 4  m , D a 2  = 1.4 4 2(0.6 1) = 0.880 m , W 2  = 1.4 4 2(0.122) =
0.176  m , and  J 2  = 1.4 4 2(0.15) = 0.216  m .

For part (a), for equal mass transfer, n =   in Eq. (3.4-10).

Using Eq. (3.4-1),
Using NP = 5.0 in Eq. (3.4-2),

The power per unit volume is

The value of 0.2752 kW/m3 is somewhat lower than the approximate guidelines of 0.8 to 2.0
for mass transfer.

For part (b), for equal liquid motion, n = 1.0.

3.4 G . M ixing Tim e s of M iscib le  Liq u id s

In one method used to study the blending or mixing time for two miscible liquids, an amount of HCl acid
is added to an equivalent of NaOH and the time required for the indicator to change color is noted. This is
a measure of molecule-molecule mixing. Other experimental methods are also used. Rapid mixing takes
place near the impeller, with slower mixing, which depends on the pumping circulation rate, in the outer
zones.

In Fig. 3.4-6, a correlation of mixing time is given for a turbine agitator (B5, M5, N1). The dimensionless
mixing factor ft is defined as

Equation 3.4-16
Figure 3.4-6. Correlation of mixing time for miscible liquids using a turbine in a baffled tank (for a plain turbine,
turbine with disk, and pitched-blade turbine). [From " Flow Patterns and Mixing Rates in Agitated Vessels"  by
K. W. Norwood and A. B. Metzner, A.I.Ch.E.J., 6, 432 (1960). Reproduced by permission of the American
Institute of Chemical Engineers, 1960.]

where t T is the mixing time in seconds. For   > 1000, since ft is approximately constant, then t TN2/3


is constant. For some other mixers it has been shown that t TN is approximately constant. For scaling up
from vessel 1 to another size vessel 2 with similar geometry and with the same power/unit volume in the
turbulent region, the mixing times are related by

Equation 3.4-17

Hence, the mixing time increases for the larger vessel. For scaling up while keeping the same mixing
time, the power/unit volume P/V increases markedly:

Equation 3.4-18

Usually, in scaling up to large-size vessels, a somewhat larger mixing time is used so that the power/unit
volume does not increase markedly.
The mixing time for a helical-ribbon agitator is as follows for   < 20 (H2):

Equation 3.4-19

Equation 3.4-20

For very viscous liquids the helical-ribbon mixer gives a much smaller mixing time than a turbine for the
same power/unit volume (M5). For nonviscous liquids, however, it gives longer times.

For a propellor agitator in a baffled tank, a mixing-time correlation is given by Biggs (B5), and that for an
unbaffled tank by Fox and Gex (F1).

For a high-efficiency impeller in a baffled tank, mixing-time correlations are given by reference (F2),
which shows that mixing times are lower than for pitched-blade agitators.

EXAMPLE 3.4-4. Scale-Up of Mixing Time in a Turbine
Agitation System.
Using the existing conditions for the turbine with a disk as in Example 3.4-1, part (a), do as
follows:

a.  Calculate the mixing time.

b.  Calculate the mixing time for a smaller vessel with a similar geometric ratio, where Dt is
0.30 m instead of 1.83 m. Do this for the same power per unit volume as used in part
(a).

c.  Using the same mixing time calculated for the smaller vessel in part (b), calculate the
new power per unit volume for the larger vessel in part (a).

S olu t ion: In part (a), Dt = 1.83 m, Da  = 0.61 m, Dt = H, N = 90/60 = 1.50 rev/s, ρ = 929

kg/m3, μ = 10 cp = 0.01 Pa · s. From Example 3.4-1,   = 5.185 × 104, Np = 5, P1 = 1.324
kW. For the tank volume,

The power per unit volume is
From Fig. 3.4-6 for   = 5.185 × 104, ft = 4.0. Substituting into Eq. (3.4-16),

For part (b), the scale-down ratio R from Eq. (3.4-8) is

Also, H2 = DT2 = 0.300 m. Using the same Pl/V1 = P2/V2 = 0.2751 kW/m3 in the turbulent
region, and Eq. (3.4-17),

Hence, t T2 = 5.73 s. This shows that the larger vessel has a marked increase in mixing time
from 5.73 to 17.30 s for equal power per unit volume.

For part (c), using the same mixing time of 5.73 s for the smaller vessel, the power per unit
volume of the larger vessel is calculated from Eq. (3.4-18) for equal mixing times:
Solving, P1/V1 = 39.73 kW/m3. This, of course, is a very large and impractical increase.

3.4 H. Flow  Nu m b e r  and  C ir cu lation R ate  in Agitation

An agitator acts like a centrifugal pump impeller without a casing and gives a flow at a certain pressure
head. This circulation rate Q in m3/s from the edge of the impeller is the flow rate perpendicular to the
impeller discharge area. Fluid velocities have been measured in mixers and have been used to calculate
the circulation rates. Data for baffled vessels have been correlated using the dimensionless flow number
NQ (U1):

Equation 3.4-21

3.4 I. S p e cial Agitation S yste m s

1. S u sp ension of solid s

In some agitation systems a solid is suspended in the agitated liquid. Examples are when a finely
dispersed solid is to be dissolved in the liquid, microorganisms are suspended in fermentation, a
homogeneous liquid-solid mixture is to be produced for feed to a process, and a suspended solid is used
as a catalyst to speed up a reaction. The suspension of solids is somewhat similar to a fluidized bed. In
the agitated system, circulation currents of the liquid keep the particles in suspension. The amount and
type of agitation needed depend mainly on the terminal settling velocity of the particles, which can be
calculated using the equations in Section 14.3. Empirical equations for predicting the power required to
suspend particles are given in references (M2, W1). Equations for pitched-blade turbines and high-
efficiency impellers are given by Corpstein et al. (C4).

2. Disp er sion of g a ses a nd  liq u id s in liq u id s

In gas-liquid dispersion processes, the gas is introduced below the impeller, which chops the gas into
very fine bubbles. The type and degree of agitation affect the size of the bubbles and the total interfacial
area. Typical of such processes are aeration in sewage treatment plants, hydrogenation of liquids by
hydrogen gas in the presence of a catalyst, absorption of a solute from the gas by the liquid, and
fermentation. Correlations are available for predicting the bubble size, holdup, and kW power needed
(C3, L1, Z1). For liquids dispersed in immiscible liquids, see reference (T1). The power required for the
agitator in gas-liquid dispersion systems can be as much as 10 to 50% less than that required when no
gas is present (C3, T2).

3. M ot ionless mixer s

Mixing of two fluids can be accomplished in motionless mixers in a pipe with no moving parts. In such
commercial devices, stationary elements inside a pipe successively divide portions of the stream and
then recombine these portions.

Laminar-flow mixers are used to mix highly viscous mixtures. One type of static mixer has a series of
fixed helical elements as shown in Fig. 3.4-7. (Note that most mixers have from six to 20 elements.) In
the first element, the flow is split into two semicircular channels and the helical shape gives the streams
a 180° twist. The next and successive elements are placed at 90° relative to each other and split the flows
into two for each element. Each split in flow creates more interfacial area between layers. When these
layers become sufficiently thin, molecular diffusion will eliminate concentration differences remaining.
When each element divides the flow into two flow channels (M6),

Equation 3.4-22

Figure 3.4-7. Two-element helical motionless mixer with element length L and pipe diameter D (M2, M6).

where n is the number of elements in series, d is the maximum striation thickness, and D is pipe
diameter. When n = 20, then about 106 divisions occur and d is a very small thickness, which enhances
the rate of diffusion.

In another commercial type of static mixer (K3), the stream is divided four times for each element. Each
element has interacting bars or corrugated sheets placed lengthwise in the pipe and at a 45° angle to the
pipe axis. The lengths L of the various types of elements vary from about 1.0 to 1.5 times the pipe
diameter. These mixers are also used in turbulent-flow mixing.

In laminar flow with helical mixers the pressure drop (and, hence, power required) is approximately six
times as large as that in the empty pipe. In turbulent flow, because of energy losses due to changes of
direction, the pressure drop can be up to several hundred times as large (M6, P1). The power loss is
typically about 10% of the power of a dynamic mixer (K3). Motionless mixers are also used for heat
transfer, chemical reactions, and dispersion of gases in liquids.

3.4 J. M ixing of Pow d e r s, Viscou s M ate r ials, and  Paste s

1. Pow d er s

In mixing of solid particles or powders it is necessary to displace parts of the powder mixture with
respect to other parts. The simplest class of devices suitable for gentle blending is the tumbler. However,
it is not usually used for breaking up agglomerates. A common type of tumbler is the double-cone
blender, in which two cones are mounted with their open ends fastened together and rotated, as shown
in Fig. 3.4-8a. Baffles can also be used internally. If an internal rotating device is also used in the double
cone, agglomerates can also be broken up. Other geometries used are a cylindrical drum with internal
baffles or twin-shell V type. Tumblers used specifically for breaking up agglomerates are rotating
cylindrical or conical shells charged with metal or porcelain steel balls or rods.

Figure 3.4-8. Mixers for powders and pastes: (a) double-cone powder mixer, (b) ribbon powder mixer with two
ribbons, (c) kneader mixer for pastes.

Another class of devices for blending solids is the stationary shell device, in which the container is
stationary and the material displacement is accomplished by single or multiple rotating inner devices. In
the ribbon mixer in Fig. 3.4-8b, a shaft with two open helical screws numbers 1 and 2 attached to it
rotates. One screw is left-handed and one right-handed. As the shaft rotates, sections of powder move in
opposite directions and mixing occurs. Other types of internal rotating devices are available for special
situations (P1). Also, in some devices both the shell and the internal device rotate.

2. Dou g h, p a st es, a nd  v iscou s ma t er ia ls

In the mixing of dough, pastes, and viscous materials, large amounts of powder are required as the
material is divided, folded, or recombined, and as different parts of the material are displaced relative to
each other so that fresh surfaces recombine as often as possible. Some machines may require jacketed
cooling to remove the heat generated.

The first type of device for this purpose is somewhat similar to those for agitating fluids, with an impeller
slowly rotating in a tank. The impeller can be a close-fitting anchor agitator as in Fig. 3.4-2b, where the
outer sweep assembly may have scraper blades. A gate impeller can also be used which has horizontal
and vertical bars that cut the paste at various levels and at the wall, which may have stationary bars. A
modified gate mixer is the shear-bar mixer, which contains vertical rotating bars or paddles passing
between vertical stationary fingers. Other modifications of these types are those where the can or
container will rotate as well as the bars and scrapers. These are called change-can mixers.

The most commonly used mixer for heavy pastes and dough is the double-arm kneader mixer. The
mixing action is bulk movement, smearing, stretching, dividing, folding, and re-combining. The most
widely used design employs two contrarotating arms of sigmoid shape which may rotate at different
speeds, as shown in Fig. 3.4-8c.
                             
                                                 
                                             
                                               
     

3.5. NON­NEWTONIAN FLUIDS

3.5A. Typ e s of Non-Ne w tonian Flu id s

As discussed in Section 2.4, Newtonian fluids are those which follow Newton's law, Eq. (3.5-1):

Equation 3.5-1

where μ is the viscosity and is a constant independent of shear rate. In Fig. 3.5-1 a plot is shown of shear
stress τ versus shear rate −dv/dr. The line for a Newtonian fluid is straight, the slope being μ.

Figure 3.5-1. Shear diagram for Newtonian and time-independent non-Newtonian fluids.

If a fluid does not follow Eq. (3.5-1), it is a non-Newtonian fluid. Then a plot of τ versus −dν/dr is not
linear through the origin for these fluids. Non-Newtonian fluids can be divided into two broad categories
on the basis of their shear-stress/shear-rate behavior: those whose shear stress is independent of time or
duration of shear (time-independent) and those whose shear stress is dependent on time or duration of
shear (time-dependent). In addition to unusual shear-stress behavior, some non-Newtonian fluids also
exhibit elastic (rubberlike) behavior, which is a function of time and results in their being called
viscoelastic fluids. These fluids exhibit normal stresses perpendicular to the direction of flow in addition
to the usual tangential stresses. Most of the emphasis here will be put on the time-independent class,
which includes the majority of non-Newtonian fluids.

3.5B. Tim e -Ind e p e nd e nt Flu id s

1. Bing ha m p la st ic flu id s

These are the simplest because, as shown in Fig. 3.5-1, they differ from Newtonian only in that the linear
relationship does not go through the origin. A finite shear stress τC (called yield stress) in N/m2 is needed
to initiate flow. Some fluids have a finite yield (shear) stress τO, but the plot of τ versus -dvldr is curved
upward or downward. However, this departure from exact Bingham plasticity is often small. Examples
of fluids with a yield stress are drilling muds, peat slurries, margarine, chocolate mixtures, greases, soap,
grain-water suspensions, toothpaste, paper pulp, and sewage sludge.

2. Pseu d op la st ic flu id s

The majority of non-Newtonian fluids are in this category and include polymer solutions or melts,
greases, starch suspensions, mayonnaise, biological fluids, detergent slurries, dispersion media in
certain pharmaceuticals, and paints. The shape of the flow curve is shown in Fig. 3.5-1, and it generally
can be represented by a power-law equation (sometimes called the Ostwald-de Waele equation):

Equation 3.5-2

where K is consistency index in N · sn /m2 or lbf · sn ft 2, and n is the flow behavior index, dimensionless.


The apparent viscosity μa  in Eq. (3.5-3) is obtained from Eqs. (3.5-1) and (3.5-2) and decreases with
increasing shear rate:

Equation 3.5-3

3. Dila t a nt  flu id s

These fluids are far less common than pseudoplastic fluids, and their flow behavior (Fig. 3.5-1) shows an
increase in apparent viscosity with increasing shear rate. The power-law equation (3.5-2) is often
applicable, but with n > 1:

Equation 3.5-4
For a Newtonian fluid, n = 1. Solutions showing dilatancy are some corn flour-sugar solutions, wet beach
sand, starch in water, potassium silicate in water, and some solutions containing high concentrations of
powder in water.

3.5C . Tim e -De p e nd e nt Flu id s

1. Thixot r op ic flu id s

These fluids exhibit a reversible decrease in shear stress with time at a constant rate of shear. This shear
stress approaches a limiting value that depends on the shear rate. Examples include some polymer
solutions, shortening, some food materials, and paints. At present the theory for time-dependent fluids
is still not completely developed.

2. R heop ect ic flu id s

These fluids are quite rare in occurrence and exhibit a reversible increase in shear stress with time at a
constant rate of shear. Examples are bentonite clay suspensions, certain sols, and gypsum suspensions.
In design procedures for thixotropic and rheopectic fluids for steady flow in pipes, the limiting flow-
property values at a constant rate of shear are sometimes used (S2, W3).

3.5D. Viscoe lastic Flu id s

Viscoelastic fluids exhibit elastic recovery from the deformations that occur during flow. They show both
viscous and elastic properties. Part of the deformation is recovered upon removal of the stress. Examples
are flour dough, napalm, polymer melts, and bitumens.

3.5E. Lam inar  Flow  of Tim e -Ind e p e nd e nt Non-Ne w tonian Flu id s

1. Flow  p r op er t ies of a  flu id

In determining the flow properties of a time-independent non-Newtonian fluid, a capillary-tube
viscometer is often used. The pressure drop ΔP N/m2 for a given flow rate q m3/s is measured in a
straight tube of length L m and diameter D m. This is repeated for different flow rates or average
velocities V m/s. If the fluid is time-independent, these flow data can be used to predict the flow in any
other pipe size.

A plot of D Δp/4L, which is τw , the shear stress at the wall in N/m2, versus 8V/D, which is proportional
to the shear rate at the wall, is shown in Fig. 3.5-2 for a power-law fluid following Eq. (3.5-5):

Equation 3.5-5

Figure 3.5-2. General flow curve for a power-law fluid in laminar flow in a tube.
where n' is the slope of the line when the data are plotted on logarithmic coordinates and K' has units of
N · sn'/m2. For n' = 1, the fluid is Newtonian; for n' < 1, pseudoplastic, or Bingham plastic if the curve
does not go through the origin; and for n' > 1, dilatant. The K', the consistency index in Eq. (3.5-5), is the
value of D Δp/4L for 8V/D = 1. The shear rate at the wall, (-dv/dr)w , is

Equation 3.5-6

Also, K' = μ for Newtonian fluids.

Equation (3.5-5) is simply another statement of the power-law model of Eq. (3.5-2) applied to flow in
round tubes, and is more convenient to use for pipe-flow situations (D2). Hence, Eq. (3.5-5) defines the
flow characteristics just as completely as Eq. (3.5-2). It has been found experimentally (M3) that for most
fluids K' and n' are constant over wide ranges of 8V/D or D Δp/4L. For some fluids this is not the case,
and K' and n' vary. Then the particular values of K' and n' used must be valid for the actual 8V/D or D
Δp/4L with which one is dealing in a design problem. This method using flow in a pipe or tube is often
used to determine the flow properties of a non-Newtonian fluid.

In many cases the flow properties of a fluid are determined using a rotational viscometer. The flow
properties K and n in Eq. (3.5-2) are determined in this manner. A discussion of the rotational viscometer
is given in Section 3.5I.

When the flow properties are constant over a range of shear stresses that occurs for many fluids, the
following equations hold (M3):

Equation 3.5-7

Equation 3.5-8
Often a generalized viscosity coefficient γ is defined as

Equation 3.5-9

where γ has units of N · sn'/m2 or lbm/ft · s2-n'

Typical flow-property constants (rheological constants) for some fluids are given in Table 3.5-1. Some
data give γ values instead of K' values, but Eq. (3.5-9) can be used to convert these values if necessary. In
some cases in the literature, K or K' values are given as dyn · sn'/cm2 or lbf · sn'/ft 2. From Appendix A.1,
the conversion factors are

Table 3.5-1. Flow-Property Constants for Non-Newtonian Fluids

  Flow-Property Constants

Fluid n' Ref.

1.5% carboxymethylcellulose in water 0.554 1.369   (S1)


3.0% CMC in water 0.566 4.17   (S1)

4% paper pulp in water 0.575 9.12   (A1)

14.3% clay in water 0.350 0.0512   (W2)


10% napalm in kerosene 0.520 1.756   (S1)
25% clay in water 0.185 0.3036   (W2)

Applesauce, brand A (297 K), density = 0.645   0.500 (C1)


1.10 g/cm3

Banana purée, brand A (297 K), density 0.458   6.51 (C1)


= 0.977 g/cm3

Honey (297 K) 1.00   5.61 (C1)


Cream, 30% fat (276 K) 1.0   0.01379 (M4)

Tomato concentrate, 5.8% total solids 0.59   0.2226 (H1)


(305 K)

2. Eq u a t ions for  flow  in a  t u b e

In order to predict the frictional pressure drop Δp in laminar flow in a tube, Eq. (3.5-5) is solved for Δp
(p0 - pL):

Equation 3.5-10

If the average velocity is desired, Eq. (3.5-5) can be rearranged to give

Equation 3.5-11

If the equations are desired in terms of K instead of K', Eqs. (3.5-7) and (3.5-8) can be substituted into
(3.5-10) and (3.5-11). Substituting Eqs. (3.5-7) and (3.5-8) into Eq. (3.5-11) and noting that V = vx av ,

Equation 3.5-12

The flow must be laminar. The generalized Reynolds number has been defined as

Equation 3.5-13

3. Fr ict ion fa ct or  met hod

Alternatively, using the Fanning friction factor method given in Eqs. (2.10-5)–(2.10-7) for Newtonian
fluids, but using the generalized Reynolds numbers,

Equation 3.5-14
Equation 3.5-15

EXAMPLE 3.5-1. Pressure Drop of Power-Law Fluid in
Laminar Flow
A power-law fluid having a density of 1041 kg/m3 is flowing through 14.9 m of a tubing having
an inside diameter of 0.0524 m at an average velocity of 0.0728 m/s. The rheological or flow
properties of the fluid are K' = 15.23 N · sn'/m2 (0.318 lbf · sn'/ft 2) and n' = 0.40.

a.  Calculate the pressure drop and friction loss using Eq. (3.5-10) for laminar flow. Check
the generalized Reynolds number to make sure that the flow is laminar.

b.  Repeat part (a) but use the friction factor method.

S olu t ion: The known data are as follows: K' = 15.23, n' = 0.40, D = 0.0524 m, V = 0.0728
m/s, L = 14.9 m, and ρ = 1041 kg/m3. For part (a), using Eq. (3.5-10),

Also, to calculate the friction loss,

Using Eq. (3.5-13),

Hence, the flow is laminar.

For part (b), using Eq. (3.5-14)
Substituting into Eq. (3.5-15),

3.5F. Fr iction Losse s in C ontr actions, Exp ansions, and  Fittings in Lam inar  Flow

Since non-Newtonian power-law fluids flowing in conduits are often in laminar flow because of their
usually high effective viscosity, losses in sudden changes of velocity and fittings are important in
laminar flow.

1. K inet ic ener g y  in la mina r  flow

In application of the total mechanical-energy balance in Eq. (2.7-28), the average kinetic energy per unit
mass of fluid is needed. For fluids, this is (S2)

Equation 3.5-16

For Newtonian fluids, α =   for laminar flow. For power-law non-Newtonian fluids,

Equation 3.5-17

For example, if n = 0.50, α = 0.585. If n = 1.00, α =  . For turbulent flow for Newtonian and non-
Newtonian flow, α = 1.0(D1).

2. Losses in cont r a ct ions a nd  fit t ing s


Skelland (S2) and Dodge and Metzner (D2) state that when a fluid leaves a tank and flows through a
sudden contraction to a pipe of diameter D2 or flows from a pipe of diameter D1 through a sudden
contraction to a pipe of D2, a vena contracta is usually formed downstream from the contraction. General
indications are that the frictional pressure losses for pseudoplastic and Bingham plastic fluids are very
similar to those for Newtonian fluids at the same generalized Reynolds numbers in laminar and
turbulent flow for contractions as well as for fittings and valves.

For contraction losses, Eq. (2.10-16) can be used, where α = 1.0 for turbulent flow; and for laminar flow
Eq. (3.5-17) can be used to determine α, since n is not 1.00.

For fittings and valves, friction losses should be determined using Eq. (2.10-17) and values from Table
2.10-1.

3. Losses in su d d en exp a nsion

For the friction loss for a non-Newtonian fluid in laminar flow through a sudden expansion from D1 to D2
diameter, Skelland (S2) gives

Equation 3.5-18

where hex is the friction loss in J/kg. In English units Eq. (3.5-18) is divided by g c and hex is in ft ·
lbf/lbm.

Equation (2.10-15) for laminar flow with α =   for a Newtonian fluid gives values reasonably close to
those of Eq. (3.5-18) for n = 1 (Newtonian fluid). For turbulent flow the friction loss can be approximated
by Eq. (2.10-15), with α = 1.0 for non-Newtonian fluids (S2).

3.5G . Tu r b u le nt Flow  and  G e ne r alize d  Fr iction Factor s

In turbulent flow of time-independent fluids the Reynolds number at which turbulent flow occurs varies
with the flow properties of the non-Newtonian fluid. In a comprehensive study Dodge and Metzner (D2)
derived a theoretical equation for turbulent flow of non-Newtonian fluids through smooth, round tubes.
The final equation is plotted in Fig. 3.5-3, where the Fanning friction factor is plotted versus the
generalized Reynolds number, NRe,gen , given in Eq. (3.5-13). Power-law fluids with flow-behavior indexes

n' between 0.36 and 1.0 were experimentally studied at Reynolds numbers up to 3.5 × 104 and the
derivation was confirmed.

Figure 3.5-3. Fanning friction factor versus generalized Reynolds number for time-independent non-
Newtonian and Newtonian fluids flowing in smooth tubes. [From D. W. Dodge and A. B. Metzner, A.I.Ch.E. J., 5,
189 (1959). With permission.]
The curves for different n' values break off from the laminar line at different Reynolds numbers to enter
the transition region. For n' = 1.0 (Newtonian), the transition region starts at NRe,gen  = 2100. Since many
non-Newtonian power-law fluids have high effective viscosities, they are often in laminar flow. The
correlation for a smooth tube also holds for a rough pipe in laminar flow.

For rough commercial pipes with various values of roughness ε/D, Fig. 3.5-3 cannot be used for turbulent
flow, since it is derived for smooth tubes. The functional dependence of the roughness values ε/D on n'
requires experimental data which are not yet available. Metzner and Reed (M3, S3) recommend use of the
existing relationship, Fig. 2.10-3, for Newtonian fluids in rough tubes using the generalized Reynolds
number NRe,gen . This is somewhat conservative, since preliminary data indicate that friction factors for
pseudoplastic fluids may be slightly smaller than for Newtonian fluids. This is also consistent with Fig.
3.5-3 for smooth tubes, which indicates lower f values for fluids with n' below 1.0 (S2).

EXAMPLE 3.5-2. Turbulent Flow of Power-Law Fluid
A pseudoplastic fluid that follows the power law, having a density of 961 kg/m3, is flowing
through a smooth, circular tube having an inside diameter of 0.0508 m at an average velocity
of 6.10 m/s. The flow properties of the fluid are n' = 0.30 and K' = 2.744 N · s n'/m2. Calculate
the frictional pressure drop for a tubing 30.5 m long.

S olu t ion: The data are as follows: K' = 2.744, n' = 0.30, D = 0.0508 m, V = 6.10 m/s, ρ = 961
kg/m3, and L = 30.5 m. Using the general Reynolds-number equation (3.5-13),
Hence, the flow is turbulent. Using Fig. 3.5-3 for NRe,gen  = 1.328 × 104 and n' = 0.30, f =
0.0032.

Substituting into Eq. (3.5-15),

3.5H. Ve locity Pr ofile s for  Non-Ne w tonian Flu id s

1. Pseu d op la st ic a nd  d ila t a nt  flu id s

For pipe flow, Eq. (3.5-2) can be written as

Equation 3.5-19

Equation (2.9-6) holds for all fluids:

Equation 2.9-6

which relates τrx with the radial distance r from the center. Equating the above two equations and
integrating between r = r and r = R0 where vx = 0,

Equation 3.5-20

At r = 0, vx = vx max and Eq. (3.5-20) becomes

Equation 3.5-21
The average velocity vx av  is given by Eq. (3.5-12):

Equation 3.5-12

Dividing Eq. (3.5-20) by (3.5-12),

Equation 3.5-22

Using Eq. (3.5-22), the velocity profile can be calculated for laminar flow of a Newtonian fluid for n = 1 to
show the parabolic profile in Fig. 3.5-4. The velocity profiles for pseudoplastic fluids (n < 1) show a flatter
profile compared to the velocity profile for a Newtonian fluid. For extreme pseudoplastic behavior for n =
0, plug flow is obtained across the entire pipe. For dilatant behavior (n > 1) the velocity profile is more
pointed and narrower. For extreme dilatant fluids (n = ∞) the velocity profile is a linear function of the
radius.

Figure 3.5-4. Dimensionless velocity profile v x /v x  av  for power-law non-Newtonian fluids.

2. Bing ha m p la st ic flu id s


For Bingham plastic fluids a finite yield stress τ0 in N/m2 is needed to initiate flow, as given in Eq. (3.5-
23):

Equation 3.5-23

The velocity profile for this fluid is more complex than that for non-Newtonian fluids. This velocity
profile for Bingham plastic fluids is shown in Fig. 3.5-5. Note the plug-flow region r = 0 to r = r 0. In this
region dvx/dr = 0 because the momentum flux or shear stress τrx is less than the yield value τ0.

Figure 3.5-5. Velocity profile and shear diagram for flow of a Bingham plastic fluid in a pipe.

In Table 3.5-2 some typical values for the rheological constants for Bingham plastic fluids are given.

Table 3.5-2. Rheological Constants for Bingham Plastic Fluids

Fluid τ , N/m 2 μ, Pa · s Ref.


0

Coal slurry (ρ = 1500 kg/m3 ) 2.0 0.03 (D4)

Molten chocolate (100°F) 20 2.0 (D4)


Printing pigment in varnish (10% by wt) 0.4 0.25 (C5)
To derive the equation for pipe flow, note that Eq. (2.9-6) holds for all fluids:

Equation 2.9-6

Substituting Eq. (2.9-6) into (3.5-23),

Equation 3.5-24

Rearranging and integrating, where νx = νx at r = r and νx = 0 at r = R,

Equation 3.5-25

The equation holds for the region where r > r 0 and up to r = R. For the plug-flow region r ≤ r 0, dvx/dr =


0. In this region, using Eq. (2.9-6) and setting τrx = τ0 at r 0,

Equation 3.5-26

Substituting Eq. (3.5-26) into (3.5-25) for r = r 0, where plug flow occurs,

Equation 3.5-27

To obtain the flow rate Q in m3/s, the following integral must be evaluated:

Equation 3.5-28
Substituting Eq. (3.5-27) into the first part of Eq. (3.5-28) and (3.5-25) into the last part and integrating,

Equation 3.5-29

where τR = (p0 - pL)R/2L, the momentum flux at the wall. This is the Buckingham-Reiner equation.

When τ0 is zero, Eq. (3.5-29) reduces to the Hagen-Poiseuille Eq. (2.9-11) for Newtonian fluids.

EXAMPLE 3.5-3. Flow Rate of a Bingham Plastic Fluid
A printing-pigment solution with properties similar to those in Table 3.5-2 is flowing in a 1.0-
cm-diameter pipe which is 10.2 m long. A pressure driving force of 4.35 kN/m2 is being used.
Calculate the flow rate Q in m3/s.

S olu t ion: From Table 3.5-2, τ0 = 0.4 N/m2 and μ = 0.25 Pa · s. Also, (p0 - p) = 4.35 kN/m2 =

4350 N/m2, L = 10.2 m, R = 1.0/2 cm = 0.005 m. Substituting into Eq. (3.5-26),

Solving,

Substituting into the following for τR,

Finally, substituting into Eq. (3.5-29),
3.5I. De te r m ination of Flow  Pr op e r tie s of Non-Ne w tonian Flu id s Using R otational
Viscom e te r

The flow-property or rheological constants of non-Newtonian fluids can be measured using pipe flow, as
discussed in Section 3.5E. Another, more important method for measuring flow properties is by using a
rotating concentric-cylinder viscometer, first described by Couette in 1890. In this device a concentric
rotating cylinder (spindle) spins at a constant rotational speed inside another cylinder. Generally, there
is a very small gap between the walls. This annulus is filled with the fluid. The torque needed to maintain
this constant rotation rate of the inner spindle is measured by means of a torsion wire from which the
spindle is suspended. A typical commercial instrument of this type is the Brookfield viscometer. Some
types rotate the outer cylinder.

The shear stress at the wall of the bob or spindle is given by

Equation 3.5-30

where τw  is the shear stress at the wall, N/m2 or kg/s2 · m; T is the measured torque, kg · m2/s2; Rb is the
radius of the spindle, m; and L is the effective length of the spindle, m. Note that Eq. (3.5-30) holds for
Newtonian and non-Newtonian fluids.

The shear rate at the surface of the spindle for non-Newtonian fluids is as follows (M6) for 0.5 < Rb/Rc <
0.99:

Equation 3.5-31

where Rc is the radius of the outer cylinder or container, m; and ω is the angular velocity of the spindle,
rad/s. Also, ω = 2πN/60, when N is the RPM. Results calculated using Eq. (3.5-31) give values very close
to those using the more complicated equation of Krieger and Maron (K2), also given in (P4, S2).

The power-law equation is given as
Equation 3.5-2

where K = N · sn /m2, kg · sn-2/m. Substituting Eqs. (3.5-30) and (3.5-31) into (3.5-2) gives

Equation 3.5-32

or,

Equation 3.5-33

where

Equation 3.5-34

Experimental data are obtained by measuring the torque T at different values of ω for a given fluid. The
flow-property constants may be evaluated by plotting log T versus log ω. The parameter n is the slope of
the straight line and the intercept is log A. The consistency factor K is now easily evaluated from Eq. (3.5-
34).

Various special cases can be derived for Eq. (3.5-31):

1. New t onia n flu id . (n = 1)

Equation 3.5-35

2. Ver y  la r g e g a p  (R b /R c  < 0.1)

This is the case of a spindle immersed in a large beaker of test fluid. Equation (3.5-31) becomes

Equation 3.5-36
Substituting Eqs. (3.5-30) and (3.5-36) into (3.5-2),

Equation 3.5-37

Again, as before, the flow-property constants can be evaluated by plotting log T versus log ω.

3. Ver y  na r r ow  g a p  (R b /R c  > 0.9 9 )

This is similar to flow between parallel plates. Taking the shear rate at radius (Rb + Rc)/2,

Equation 3.5-38

This equation, then, is the same as Eq. (3.5-35).

3.5J. Pow e r  R e q u ir e m e nts in Agitation and  M ixing of Non-Ne w tonian Flu id s

For correlating the power requirements in agitation and mixing of non-Newtonian fluids, the power
number NP is defined by Eq. (3.4-2), which is also the equation used for Newtonian fluids. However, the
definition of the Reynolds number is much more complicated than for Newtonian fluids, since the
apparent viscosity is not constant for non-Newtonian fluids but varies with the shear rates or velocity
gradients in the vessel. Several investigators (G1, M1) have used an average apparent viscosity μa , which
is used in the Reynolds number as follows:

Equation 3.5-39

The average apparent viscosity can be related to the average shear rate or average velocity gradient by the
following method. For a power-law fluid,

Equation 3.5-40
For a Newtonian fluid,

Equation 3.5-41

Combining Eqs. (3.5-40) and (3.5-41),

Equation 3.5-42

Metzner and others (G1, M1) found experimentally that the average shear rate (dv/dy)av  for
pseudoplastic liquids (n < 1) varies approximately as follows with the rotational speed:

Equation 3.5-43

Hence, combining Eqs. (3.5-42) and (3.5-43),

Equation 3.5-44

Substituting into Eq. (3.5-39),

Equation 3.5-45

Equation (3.5-45) has been used to correlate data for a flat six-blade turbine with disk in pseudoplastic
liquids, and the dashed curve in Fig. 3.5-6 shows the correlation (M1). The solid curve applies to
Newtonian fluids (R1). Both sets of data were obtained for four baffles with Dt/J = 10, Da /W = 5, and 
. However, since it has been shown that the difference in results for Dt/J = 10 and Dt/J = 12 is
very slight (R1), this Newtonian line can be considered the same as curve 1 in Fig. 3.4-5. The curves in
Fig. 3.5-6 show that the results are identical for the Reynolds number range 1–2000, except that they
differ only in the Reynolds number range 10–100, where the pseudoplastic fluids use less power than the
Newtonian fluids. The flow patterns for the pseudoplastic fluids show much greater velocity-gradient
changes than do the Newtonian fluids in the agitator. The fluid far from the impeller may be moving in
slow laminar flow with a high apparent viscosity. Data for fan turbines and propellers are also available
(M1).

Figure 3.5-6. Power correlation in agitation for a flat, six-blade turbine with disk in pseudoplastic non-
Newtonian and Newtonian fluids (G1, M1, R1): Da /W = 5, L/W = 5/4, Dt/J = 10.
                             
                                                 
                                             
                                               
     

3.6. DIFFERENTIAL EQUATIONS OF CONTINUITY

3.6 A. Intr od u ction

In Sections 2.6, 2.7, and 2.8, overall mass, energy, and momentum balances allowed us to solve many
elementary problems in fluid flow. These balances were done on an arbitrary finite volume sometimes
called a control volume. In these total-energy, mechanical-energy, and momentum balances, we only
needed to know the state of the inlet and outlet streams and the exchanges with the surroundings.

These overall balances were powerful tools in solving various flow problems because they did not require
knowledge of what goes on inside the finite control volume. Also, in the simple shell-momentum
balances made in Section 2.9, expressions were obtained for the velocity distribution and pressure drop.
However, to advance in our study of these flow systems, we must investigate in greater detail what goes
on inside this finite control volume. To do this, we now use a differential element for a control volume.
The differential balances will be somewhat similar to the overall and shell balances, but now we shall
make the balance in a single phase and integrate to the phase boundary using the boundary conditions.
In the balances done earlier, a balance was made for each new system studied. It is not necessary to
formulate new balances for each new flow problem. It is often easier to start with the differential
equations for the conservation of mass (equation of continuity) and the conservation of momentum in
general form. Then these equations are simplified by discarding unneeded terms for each particular
problem.

For nonisothermal systems, a general differential equation for conservation of energy will be considered
in Chapter 5. Also, in Chapter 7, a general differential equation of continuity for a binary mixture will be
derived. The differential-momentum-balance equation to be derived is based on Newton's second law and
allows us to determine the way velocity varies with position and time as well as the pressure drop in
laminar flow. The equation of momentum balance can be used for turbulent flow with certain
modifications.

Often these conservation equations are called equations of change, since they describe the variations in
the properties of the fluid with respect to position and time. Before we derive these equations, a brief
review of the different types of derivatives with respect to time which occur in these equations and a brief
description of vector notation will be given.

3.6 B. Typ e s of Tim e  De r iv ativ e s and  Ve ctor  Notation

1. Pa r t ia l t ime d er iv a t iv e

Various types of time derivatives are used in the derivations to follow. The most common type of
derivative is the partial time derivative. For example, suppose that we are interested in the mass
concentration or density ρ in kg/m3 in a flowing stream as a function of position x, y, z and time t. The
partial time derivative of ρ is ∂ρ/∂t. This is the local change of density with time at a fixed point x, y, z.

2. Tot a l t ime d er iv a t iv e


Suppose that we want to measure the density in the stream while we are moving about in the stream with
velocities in the x, y, and z directions of dx/dt, dy/dt, and dz/dt, respectively. The total derivative dρ/dt
is

Equation 3.6-1

This means that the density is a function of t and of the velocity components dx/dt, dy/dt, and dz/dt at
which the observer is moving.

3. S u b st a nt ia l t ime d er iv a t iv e

Another useful type of time derivative is obtained if the observer floats along with the velocity ν of the
flowing stream and notes the change in density with respect to time. This is called the derivative that
follows the motion, or the substantial time derivative, Dρ/Dt:

Equation 3.6-2

where νx, νy , and νz are the velocity components of the stream velocity ν, which is a vector. This
substantial derivative is applied to both scalar and vector variables. The term (ν · ∇ρ) will be discussed
in part 6 of Section 3.6B.

4 . S ca la r s

The physical properties encountered in momentum, heat, and mass transfer can be placed in several
categories: scalars, vectors, and tensors. Scalars are quantities such as concentration, temperature,
length, volume, time, and energy. They have magnitude but no direction and are considered to be zero-
order tensors. The common mathematical algebraic laws hold for the algebra of scalars. For example, bc
= cd, b(cd) = (bc)d, and so on.

5. Vect or s

Velocity, force, momentum, and acceleration are considered vectors since they have magnitude and
direction. They are regarded as first-order tensors and are written in boldface letters in this text, such as ν
for velocity. The addition of two vectors B + C  by parallelogram construction and the subtraction of two
vectors B - C  are shown in Fig. 3.6-1. The vector B is represented by its three projections Bx, By , and Bz
on the x, y, and z axes, and

Equation 3.6-3
Figure 3.6-1. Addition and subtraction of vectors: (a) addition of vectors, B + C; (b) subtraction of vectors, B - 
C.

where i, j, and k  are unit vectors along the axes x, y, and z, respectively.

In multiplying a scalar quantity r or s by a vector B, the following hold:

Equation 3.6-4

Equation 3.6-5

Equation 3.6-6

The following also hold:

Equation 3.6-7

Equation 3.6-8

Equation 3.6-9

Equation 3.6-10
where ϕBC is the angle between two vectors and is <180°.

Second-order tensors τ arise primarily in momentum transfer and have nine components. They are
discussed elsewhere (B2).

6 . Differ ent ia l op er a t ions w it h sca la r s a nd  v ect or s

The gradient or "grad" of a scalar field is

Equation 3.6-11

where ρ  is a scalar such as density.

The divergence or "div" of a vector ν is

Equation 3.6-12

where ν is a function of νx, νy , and νz.

The Laplacian of a scalar field is

Equation 3.6-13

Other operations that may be useful are

Equation 3.6-14

Equation 3.6-15

Equation 3.6-16
3.6 C . Diffe r e ntial Eq u ation of C ontinu ity

1. Der iv a t ion of eq u a t ion of cont inu it y

A mass balance will be made for a pure fluid flowing through a stationary volume element Δx Δy Δz
which is fixed in space as in Fig. 3.6-2. The mass balance for the fluid with a concentration of ρ kg/m3  is

Equation 3.6-17

Figure 3.6-2. Mass balance for a pure fluid flowing through a fixed volume Δx Δy Δz in space.

In the x direction the rate of mass entering the face at x having an area of Δy Δz m2 is (ρvx)x Δy Δz kg/s

and that leaving at x + Δx is (ρνx)x+Δx Δy Δz. The term (ρνx) is a mass flux in kg/s · m2. Mass entering
and mass leaving in the y  and z directions are also shown in Fig. 3.6-2.

The rate of mass accumulation in the volume Δx Δy Δz is

Equation 3.6-18

Substituting all these expressions into Eq. (3.6-17) and dividing both sides by Δx Δy Δz,
Equation 3.6-19

[View full size image]

Taking the limit as Δx, Δy, and Δz approach zero, we obtain the equation of continuity or conservation of
mass for a pure fluid:

Equation 3.6-20

The vector notation on the right side of Eq. (3.6-20) comes from the fact that ν is a vector. Equation (3.6-
20) tells us how density ρ changes with time at a fixed point resulting from the changes in the mass
velocity vector ρν.

We can convert Eq. (3.6-20) into another form by carrying out the actual partial differentiation:

Equation 3.6-21

Rearranging Eq. (3.6-21),

Equation 3.6-22

The left-hand side of Eq. (3.6-22) is the same as the substantial derivative in Eq. (3.6-2). Hence, Eq. (3.6-
22) becomes

Equation 3.6-23

2. Eq u a t ion of cont inu it y  for  const a nt  d ensit y

Often in engineering with liquids that are relatively incompressible, the density ρ  is essentially constant.
Then ρ  remains constant for a fluid element as it moves along a path following the fluid motion, or
Dρ /Dt = 0. Hence, Eq. (3.6-23) becomes, for a fluid of constant density at steady or unsteady state,
Equation 3.6-24

At steady state, ∂p /∂t = 0 in Eq. (3.6-22).

EXAMPLE 3.6-1. Flow over a Flat Plate
An incompressible fluid flows past one side of a flat plate. The flow in the x direction is parallel
to the flat plate. At the leading edge of the plate the flow is uniform at the free stream velocity
νx0. There is no velocity in the z direction. The y  direction is the perpendicular distance from
the plate. Analyze this case using the equation of continuity.

S olu t ion: For this case where ρ  is constant, Eq. (3.6-24) holds:

Equation 3.6-24

Since there is no velocity in the z direction, we obtain

Equation 3.6-25

At a given small value of y  close to the plate, the value of νx must decrease from its free stream
velocity vx0 as it passes the leading edge in the x direction because of fluid friction. Hence,
∂νx/∂x is negative. Then from Eq. (3.6-25), ∂νy /∂y  is positive and there is a component of
velocity away from the plate.

3. C ont inu it y  eq u a t ion in cy lind r ica l a nd  sp her ica l coor d ina t es

It is often convenient to use cylindrical coordinates to solve the equation of continuity if fluid is flowing
in a cylinder. The coordinate system as related to rectangular coordinates is shown in Fig. 3.6-3a. The
relations between rectangular x, y , z and cylindrical r, θ , z coordinates are

Equation 3.6-26
Figure 3.6-3. Curvilinear coordinate systems: (a) cylindrical coordinates, (b) spherical coordinates.

Using the relations from Eq. (3.6-26) with Eq. (3.6-20), the equation of continuity in cylindrical
coordinates is

Equation 3.6-27

For spherical coordinates the variables r, θ, and ϕ are related to x, y, z by the following, as shown in Fig.
3.6-3b:

Equation 3.6-28

The equation of continuity in spherical coordinates becomes

Equation 3.6-29
                             
                                                 
                                             
                                               
     

3.7. DIFFERENTIAL EQUATIONS OF MOMENTUM 
TRANSFER OR MOTION

3.7A. De r iv ation of Eq u ations of M om e ntu m  Tr ansfe r

The equation of motion is really the conservation-of-momentum equation (2.8-3), which we can write as

Equation 3.7-1

We will make a balance on an element as in Fig. 3.6-2. First we shall consider only the x component of
each term in Eq. (3.6-30). The y and z components can be described in an analogous manner.

The rate at which the x component of momentum enters the face at x in the x direction by convection is
(ρνxνx)x Δy Δz, and the rate at which it leaves at x + Δx is (ρνxνx)x+Δx Δy Δz. The quantity (ρvx) is the

concentration in momentum/m3 or (kg · m/s)/m3, and it is multiplied by νx to give the momentum flux

as momentum/s · m2.

The x component of momentum entering the face at y is (ρνy νx)y  Δx Δz, and leaving at y + Δy it is


(ρνy νx)y+Δy  Δx Δz. For the face at z we have (ρνzνx)z Δx Δy entering, and at z + Δz we have (ρνzνx)z+Δz Δx
Δy leaving. Hence, the net convective x momentum flow into the volume element Δx Δy Δz is

Equation 3.7-2

[View full size image]

Momentum flows in and out of the volume element by the mechanisms of convection or bulk flow as
given in Eq. (3.7-2) and also by molecular transfer (by virtue of the velocity gradients in laminar flow).
The rate at which the x component of momentum enters the face at x by molecular transfer is (τxx)x Δy
Δz, and the rate at which it leaves the surface at x + Ax is (τxx)x+Δx Δy Δz. The rate at which it enters the
face at y is (τyx)y  Δx Δz, and it leaves at y + Δy at a rate of (τyx)y+Δy  Δx Δz. Note that τyx is the flux of x
momentum through the face perpendicular to the y axis. Writing a similar equation for the remaining
faces, the net x component of momentum by molecular transfer is

Equation 3.7-3

[View full size image]
These molecular fluxes of momentum may be considered as shear stresses and normal stresses. Hence,
τyx is the x-direction shear stress on the y face and τzx the shear stress on the z face. Also, τxx is the
normal stress on the x face.

The net fluid-pressure force acting on the element in the x direction is the difference between the forces
acting at x and x + Δx:

Equation 3.7-4

The gravitational force g x acting on a unit mass in the x direction is multiplied by the mass of the
element to give

Equation 3.7-5

where g x is the x component of the gravitational vector g .

The rate of accumulation of x momentum in the element is

Equation 3.7-6

Substituting Eqs. (3.7-2)-(3.7-6) into (3.7-1), dividing by Δx Δy Δz, and taking the limit as Δx, Δy, and
Δz approach zero, we obtain the x component of the differential equation of motion:

Equation 3.7-7

The y and z components of the differential equation of motion are, respectively,

Equation 3.7-8
Equation 3.7-9

We can use Eq. (3.6-20), which is the continuity equation, and Eq. (3.7-7) to obtain an equation of
motion for the x component and also do the same for the y and z components as follows:

Equation 3.7-10

[View full size image]

Equation 3.7-11

[View full size image]

Equation 3.7-12

[View full size image]

Adding vectorially, we obtain an equation of motion for a pure fluid:

Equation 3.7-13

We should note that Eqs. (3.7-7)-(3.7-13) are valid for any continuous medium.

3.7B. Eq u ations of M otion for  Ne w tonian Flu id s w ith Var ying De nsity and  Viscosity
In order to use Eqs. (3.7-7)-(3.7-13) to determine velocity distributions, expressions must be used for the
various stresses in terms of velocity gradients and fluid properties. For Newtonian fluids the expressions
for the stresses τxx, τyx, τzx, and so on, have been related to the velocity gradients and the fluid viscosity
μ (B1, B2, D1) and are as follows:

1. S hea r -st r ess comp onent s for  New t onia n flu id s in r ect a ng u la r  coor d ina t es

Equation 3.7-14

Equation 3.7-15

Equation 3.7-16

Equation 3.7-17

Equation 3.7-18

Equation 3.7-19

Equation 3.7-20
2. S hea r -st r ess comp onent s for  New t onia n flu id s in cy lind r ica l coor d ina t es

Equation 3.7-21

Equation 3.7-22

Equation 3.7-23

Equation 3.7-24

Equation 3.7-25

Equation 3.7-26

Equation 3.7-27
3. S hea r -st r ess comp onent s for  New t onia n flu id s in sp her ica l coor d ina t es

Equation 3.7-28

Equation 3.7-29

Equation 3.7-30

Equation 3.7-31

Equation 3.7-32

Equation 3.7-33

Equation 3.7-34
4 . Eq u a t ion of mot ion for  New t onia n flu id s w it h v a r y ing  d ensit y  a nd  v iscosit y

After Eqs. (3.7-14)-(3.7-20) for shear-stress components are substituted into Eq. (3.7-10) for the x
component of momentum, we obtain the general equation of motion for a Newtonian fluid with varying
density and viscosity:

Equation 3.7-35

Similar equations are obtained for the y  and z components of momentum.

3.7C . Eq u ations of M otion for  Ne w tonian Flu id s w ith C onstant De nsity and  Viscosity

The equations above are seldom used in their complete forms. When the density ρ  and the viscosity μ are
constant where (∇ · ν) = 0, the equations are simplified and we obtain the equations of motion for
Newtonian fluids. These equations are also called the Navier-Stokes equations.

1. Eq u a t ion of mot ion in r ect a ng u la r  coor d ina t es

For Newtonian fluids for constant ρ  and μ for the x component, y  component, and z component we


obtain, respectively,

Equation 3.7-36

Equation 3.7-37

Equation 3.7-38
Combining the three equations for the three components, we obtain

Equation 3.7-39

2. Eq u a t ion of mot ion in cy lind r ica l coor d ina t es

These equations are as follows for Newtonian fluids for constant ρ and μ for the r, θ , and z components,
respectively:

Equation 3.7-40

[View full size image]

Equation 3.7-41

[View full size image]

Equation 3.7-42

[View full size image]

3. Eq u a t ion of mot ion in sp her ica l coor d ina t es

The equations for Newtonian fluids are given below for constant ρ and μ for the r, θ, and ϕ components,
respectively:

Equation 3.7-43

[View full size image]
Equation 3.7-44

[View full size image]

Equation 3.7-45

[View full size image]

where in the three equations above,

Equation 3.7-46

Significant advantages and uses arise in the transformation from rectangular coordinates to cylindrical

coordinates. For example, in Eq. (3.7-40) the term   is the centrifugal force. This gives the force in
the r direction (radial) resulting from the motion of the fluid in the θ direction. Note that this term is
obtained automatically from the transformation from rectangular to cylindrical coordinates. It does not
have to be added to the equation on physical grounds.

The Coriolis force ρνr νθ/r also arises automatically in the transformation of coordinates in Eq. (3.7-41).
It is the effective force in the θ direction when there is flow in both the r and the θ directions, as in the
case of flow near a rotating disk.
                             
                                                 
                                             
                                               
     

3.8. USE OF DIFFERENTIAL EQUATIONS OF CONTINUITY AND
MOTION

3.8A. Intr od u ction

The purpose and uses of the differential equations of motion and continuity, as mentioned previously,
are to apply these equations to any viscous-flow problem. For a given specific problem, the terms that are
zero or near zero are simply discarded and the remaining equations used to solve for the velocity, density,
and pressure distributions. Of course, it is necessary to know the initial conditions and the boundary
conditions to solve the equations. Several examples will be given to illustrate the general methods used.

We will consider cases for flow in specific geometries that can easily be described mathematically, such as
flow between parallel plates and in cylinders.

3.8B. Diffe r e ntial Eq u ations of C ontinu ity and  M otion for  Flow  b e tw e e n Par alle l Plate s

Two examples will be considered, one for horizontal plates and one for vertical plates.

EXAMPLE 3.8­1. Laminar Flow Between Horizontal Parallel
Plates
Derive the equation giving the velocity distribution at steady state for laminar flow of a
constant-density fluid with constant viscosity flowing between two flat and parallel plates.
The velocity profile desired is at a point far from the inlet or outlet of the channel. The two
plates will be considered to be fixed and of infinite width, with the flow driven by the pressure
gradient in the x direction.

S olu t ion: Assuming that the channel is horizontal, Fig. 3.8-1 shows the axes selected, with
flow in the x direction and the width in the z direction. The velocities νy  and νz are then zero.
The plates are a distance 2y 0 apart.

Figure 3.8-1. Flow between two parallel plates in Example 3.8-1.
The continuity equation (3.6-24) for constant density is

Equation 3.6-24

Since νy  and νz are zero, Eq. (3.6-24) becomes

Equation 3.8-1

The Navier-Stokes equation for the x component is

Equation 3.7-36

[View full size image]

Also, ∂νx/∂t = 0 for steady state, νy  = 0, νz = 0, ∂ νx/∂x = 0, ∂2νx/∂x2 = 0. We can see that

∂νx/∂z = 0, since there is no change of νx with z. Then ∂2νx/∂z2 = 0. Making these
substitutions into Eq. (3.7-36), we obtain

Equation 3.8-2
In fluid-flow problems we will be concerned with gravitational force only in the vertical
direction for g x, which is g, the gravitational force, in m/s2. We shall combine the static
pressure p and the gravitational force and call them simply p, as follows (note that g x = 0 for
the present case of a horizontal pipe but is not zero for the general case of a nonhorizontal
pipe):

Equation 3.8-3

where h is the distance upward from any chosen reference plane (h is in the direction opposed
to gravity). Then Eq. (3.8-2) becomes

Equation 3.8-4

We can see that p is not a function of z. Also, assuming that 2y 0 is small, p is not a function of
y. (Some references avoid this problem and simply use p as a dynamic pressure, which is
rigorously correct since dynamic pressure gradients cause flow. In a fluid at rest, the total
pressure gradient is the hydrostatic pressure gradient, and the dynamic pressure gradient is
zero.) Also, ∂p/∂x is a constant in this problem, since νx is not a function of x. Then Eq. (3.8-
4) becomes an ordinary differential equation:

Equation 3.8-5

Integrating Eq. (3.8-5) once, using the condition dνx/dy = 0 at y = 0 for symmetry,

Equation 3.8-6

Integrating again, using νx = 0 at y = y 0,

Equation 3.8-7
The maximum velocity in Eq. (3.8-7) occurs when y = 0, giving

Equation 3.8-8

Combining Eqs. (3.8-7) and (3.8-8),

Equation 3.8-9

Hence, a parabolic velocity profile is obtained. This result was also obtained in Eq. (2.9-9)
when using a shell-momentum balance.

The results obtained in Example 3.8-1 could also have been obtained by making a force balance on a
differential element of fluid and using the symmetry of the system to omit certain terms.

EXAMPLE 3.8-2. Laminar Flow Between Vertical Plates
with One Plate Moving
A Newtonian fluid is confined between two parallel and vertical plates as shown in Fig. 3.8-2
(W6). The surface on the left is stationary and the other is moving vertically at a constant
velocity ν0. Assuming that the flow is laminar, solve for the velocity profile.

Figure 3.8-2. Flow between vertical parallel plates in Example 3.8-2.

S olu t ion: The equation to use is the Navier-Stokes equation for the y  coordinate, Eq. (3.7-37):

Equation 3.7-37
At steady state, ∂νy /∂t = 0. The velocities νx and νz  = 0. Also, ∂νy /∂y  = 0 from the continuity
equation, ∂νy /∂z = 0, and ρ g y  = -ρ g . The partial derivatives become derivatives and Eq. (3.7-
37) becomes

Equation 3.8-10

This is similar to Eq. (3.8-2) in Example 3.8-1. The pressure gradient dp/dy is constant.
Integrating Eq. (3.8-10) once yields

Equation 3.8-11

Integrating again gives

Equation 3.8-12

The boundary conditions are at x = 0, νy  = 0 and at x = H, νy  = ν0. Solving for the constants,


C 1 = ν0/H - (H/2μ)(dp/dy + ρg) and C 2 = 0. Hence, Eq. (3.8-12) becomes

Equation 3.8-13

3.8C . Diffe r e ntial Eq u ations of C ontinu ity and  M otion for  Flow  in S tationar y and  R otating
C ylind e r s
Several examples will be given for flow in stationary and rotating cylinders.

EXAMPLE 3.8-3. Laminar Flow in a Circular Tube
Derive the equation for steady-state viscous flow in a horizontal tube of radius r 0, where the
fluid is far from the tube inlet. The fluid is incompressible and μ is a constant. The flow is
driven in one direction by a constant-pressure gradient.

S olu t ion: The fluid will be assumed to flow in the z direction in the tube, as shown in Fig. 3.8-
3. The y direction is vertical and the x direction horizontal. Since νx and νy  are zero, the
continuity equation becomes ∂vz/∂z = 0. For steady state ∂vz/∂t = 0. Then substituting into
Eq. (3.7-38) for the z component, we obtain

Equation 3.8-14

Figure 3.8-3. Horizontal flow in a tube in Example 3.8-3.

To solve Eq. (3.8-14), we can use cylindrical coordinates from Eq. (3.6-26), giving

Equation 3.6-26

Substituting these into Eq. (3.8-14),

Equation 3.8-15
The flow is symmetrical about the z axis, so ∂2νz/∂θ2 is zero in Eq. (3.8-15). As before, dp/dz is
a constant, and Eq. (3.8-15) becomes

Equation 3.8-16

Alternatively, Eq. (3.7-42) in cylindrical coordinates can be used for the z component and the
terms that are zero discarded:

Equation 3.7-42

As before, ∂νz/∂t = 0, ∂2νz/∂θ2 = 0, νr  = 0, ∂vz/∂θ = 0, ∂νz/∂z = 0. Then Eq. (3.7-42) becomes
identical to Eq. (3.8-16).

The boundary conditions for the first integration are dνz/dr = 0 at r = 0. For the second
integration, νz = 0 at r = r 0 (tube radius). The result is

Equation 3.8-17

Converting to the maximum velocity as before,

Equation 3.8-18

If Eq. (3.8-17) is integrated over the pipe cross section using Eq. (2.9-10) to give the average
velocity νz av ,
Equation 3.8-19

Integrating to obtain the pressure drop from z = 0 for p = p1 to z = L for p = p2, we obtain

Equation 3.8-20

where D = 2r 0. This is the Hagen-Poiseuille equation, derived previously as Eq. (2.9-11).

EXAMPLE 3.8-4. Laminar Flow in a Cylindrical Annulus
Derive the equation for steady-state laminar flow inside the annulus between two concentric
horizontal pipes. This type of flow occurs often in concentric-pipe heat exchangers.

S olu t ion: In this case Eq. (3.8-16) also still holds. However, the velocity in the annulus will
reach a maximum at some radius r = r max which is between r 1 and r 2, as shown in Fig. 3.8-4.
For the first integration of Eq. (3.8-16), the boundary conditions are dνz/dr = 0 at r = r max,
which gives

Equation 3.8-21

Figure 3.8-4. Flow through a cylindrical annulus.

Also, for the second integration of Eq. (3.8-21), νz = 0 at the inner wall where r = r 1, giving
Equation 3.8-22

Repeating the second integration but for νz = 0 at the outer wall where r = r 2, we obtain

Equation 3.8-23

Combining Eqs. (3.8-22) and (3.8-23) and solving for r max,

Equation 3.8-24

In Fig. 3.8-4 the velocity profile predicted by Eq. (3.8-23) is plotted. For the case where r 1 = 0,
r max in Eq. (3.8-24) becomes zero and Eq. (3.8-23) reduces to Eq. (3.8-17) for a single circular
pipe.

EXAMPLE 3.8-5. Velocity Distribution for Flow Between
Coaxial Cylinders
Tangential laminar flow of a Newtonian fluid with constant density is occurring between two
vertical coaxial cylinders in which the outer one is rotating (S4) with an angular velocity of ω,
as shown in Fig. 3.8-5. It can be assumed that end effects can be neglected. Determine the
velocity and the shear-stress distributions for this flow.

Figure 3.8-5. Laminar flow in the region between two coaxial cylinders in Example 3.8-5.
S olu t ion: On physical grounds the fluid moves in a circular motion; the velocity νr  in the
radial direction is zero and νz in the axial direction is zero. Also, ∂ρ/∂t = 0 at steady state.
There is no pressure gradient in the θ direction. The equation of continuity in cylindrical
coordinates as derived before is

Equation 3.6-27

All terms in this equation are zero.

The equations of motion in cylindrical coordinates, Eqs. (3.7-40), (3.7-41), and (3.7-42),
reduce to the following, respectively:

Equation 3.8-25

Equation 3.8-26

Equation 3.8-27

Integrating Eq. (3.8-26),

Equation 3.8-28

To solve for the integration constants C 1 and C 2, the following boundary conditions are used:


at r = R1, νθ = 0; at r = R2, νθ = ωR2. The final equation is

Equation 3.8-29
Using the shear-stress component for Newtonian fluids in cylindrical coordinates,

Equation 3.7-31

The last term in Eq. (3.7-31) is zero. Substituting Eq. (3.8-29) into (3.7-31) and differentiating
gives

Equation 3.8-30

The torque T that is necessary to rotate the outer cylinder is the product of the force times the
lever arm:

Equation 3.8-31

where H is the length of the cylinder. This type of device has been used to measure fluid
viscosities from observations of angular velocities and torque and has also been used as a
model for some friction bearings.

EXAMPLE 3.8-6. Rotating Liquid in a Cylindrical Container
A Newtonian fluid of constant density is in a vertical cylinder of radius R (Fig. 3.8-6) with the
cylinder rotating about its axis at angular velocity ω (B2). Find the shape of the free surface at
steady state.

Figure 3.8-6. Liquid being rotated in a container with a free surface in Example 3.8-6.
S olu t ion: The system can be described in cylindrical coordinates. As in Example 3.8-5, at
steady state, νr  = νz = 0 and g r  = g θ = 0. The final equations in cylindrical coordinates given
below are the same as Eqs. (3.8-25)-(3.8-27) for Example 3.8-5, except that g z = -g in Eq. (3.8-
27):

Equation 3.8-32

Equation 3.8-33

Equation 3.8-34

Integration of Eq. (3.8-33) gives the same equation as in Example 3.8-5:

Equation 3.8-28

The constant C 2 must be zero since νθ cannot be infinite at r = 0. At r = R, the velocity νθ = Rω.
Hence, C 1 = ω and we obtain
Equation 3.8-35

Combining Eqs. (3.8-35) and (3.8-32),

Equation 3.8-36

Hence, we see that Eqs. (3.8-36) and (3.8-34) show that pressure depends upon r because of
the centrifugal force and upon z because of the gravitational force:

Equation 3.8-34

Since the term p is a function of position, we can write the total differential of pressure as

Equation 3.8-37

Combining Eqs. (3.8-34) and (3.8-36) with (3.8-37) and integrating,

Equation 3.8-38

The constant of integration can be determined, since p = p0 at r = 0 and z = z0. The equation
becomes

Equation 3.8-39

The free surface consists of all points on this surface at p = p0. Hence,

Equation 3.8-40
This shows that the free surface is in the shape of a parabola.
                             
                                                 
                                             
                                               
     

3.9. OTHER METHODS FOR SOLUTION OF DIFFERENTIAL
EQUATIONS OF MOTION

3.9 A. Intr od u ction

In Section 3.8 we considered examples where the Navier-Stokes differential equations of motion could be
solved analytically. These cases were used where there was only one non-vanishing component of the
velocity. To solve these equations for flows in two and three directions is quite complex.

In this section we will consider some approximations that simplify the differential equations to allow us
to obtain analytical solutions. Terms will be omitted which are quite small compared to the terms
retained.

Three cases will be considered in this section: inviscid flow, potential flow, and creeping flow. The fourth
case, for boundary-layer flow, will be considered in Section 3.10. The solution of these equations may be
simplified by using a stream function ψ(x, y) and/or a velocity potential φ(x, y) rather than the terms of
the velocity components νx, νy , and vz.

3.9 B. S tr e am  Fu nction

The stream function ψ(x, y) is a convenient parameter by which we can represent two-dimensional,
steady, incompressible flow. This stream function ψ in m2/s is related to the velocity components νx and
νy  by

Equation 3.9-1

These definitions of νx and νy  can then be used in the x and y components of the differential equation of
motion, Eqs. (3.7-36) and (3.7-37), together with νz = 0, to obtain a differential equation for ψ that is
equivalent to the Navier-Stokes equation. Details are given elsewhere (B2).

The stream function is very useful because of its physical significance, that is, that in steady flow, lines
defined by ψ = constant are streamlines, which are the actual curves traced out by the particles of fluid. A
stream function exists for all two-dimensional, steady, incompressible flow whether viscous or inviscid
and whether rotational or irrotational.

EXAMPLE 3.9­1. Stream Function and Streamlines
The stream function relationship is given as ψ = xy. Find the equations for the components of
velocity. Also plot the streamlines for a constant ψ = 4 and ψ = 1.

S olu t ion: Using Eq. (3.9-1),
To determine the streamline for ψ = constant = 1 = xy, assume that y = 0.5 and solve for x:

Hence, x = 2. Repeating, for y = 1, x = 1; for y = 2, x = 0.5; for y = 5, x = 0.2, and so on. Doing
the same for ψ = constant = 4, the streamlines for ψ = 1 and ψ = 4 are plotted in Fig. 3.9-1. A
possible flow model is flow around a corner.

Figure 3.9-1. Plot of streamlines for ψ = xy for Example 3.9-1.

3.9 C . Diffe r e ntial Eq u ations of M otion for  Id e al Flu id s (Inv iscid  Flow )

Special equations for ideal or inv iscid  fluids can be obtained for a fluid having a constant density and


zero viscosity. These are called the Euler equations. Equations (3.7-36)-(3.7-38) for the x, y, and z
components of momentum become

Equation 3.9-2
Equation 3.9-3

Equation 3.9-4

At very high Reynolds numbers the viscous forces are quite small compared to the inertia forces and the
viscosity can be assumed as zero. These equations are useful in calculating pressure distribution at the
outer edge of the thin boundary layer in flow past immersed bodies. Away from the surface outside the
boundary layer this assumption of an ideal fluid is often valid.

3.9 D. Pote ntial Flow  and  Ve locity Pote ntial

The velocity potential or potential function ϕ(x, y) in m2/s is useful in inviscid flow problems and is
defined as

Equation 3.9-5

This potential exists only for a flow with zero angular velocity, or irrotationality. This type of flow of an
ideal or inviscid fluid (ρ  = constant, μ = 0) is called potential flow. Additionally, the velocity potential ϕ
exists for three-dimensional flows, whereas the stream function does not. The vorticity of a fluid is
defined as follows:

Equation 3.9-6

or,

Equation 3.9-7
where 2ω z is the vorticity and ω z in s-1 is angular velocity about the z axis. If 2ω z = 0, the flow is
irrotational and a potential function exists.

Using Eq. (3.6-24), the conservation-of-mass equation for flows in the x and y directions is as follows for
constant density:

Equation 3.9-8

Differentiating νx in Eq. (3.9-5) with respect to x and νy  with respect to y  and substituting into Eq. (3.9-


8),

Equation 3.9-9

This is Laplace's equation in rectangular coordinates. If suitable boundary conditions exist or are known,
Eq. (3.9-9) can be solved to give ϕ(x, y). Then the velocity at any point can be obtained using Eq. (3.9-5).
Techniques for solving this equation include using numerical analysis, conformal mapping, and
functions of a complex variable, and are given elsewhere (B2, S3). Euler's equations can then be used to
find the pressure distribution.

When the flow is inviscid and irrotational, a similar type of Laplace equation is obtained from Eq. (3.9-7)
for the stream function:

Equation 3.9-10

Lines of constant φ are called equal potential lines and for potential flow are everywhere perpendicular
(orthogonal) to lines of constant ψ. This can be proved as follows. A line of constant ψ would be such that
the change in ψ is zero:

Equation 3.9-11

Then, substituting Eq. (3.9-1) into the above,

Equation 3.9-12
Also, for lines of constant φ,

Equation 3.9-13

Equation 3.9-14

Hence,

Equation 3.9-15

An example of the use of the stream function is in obtaining the flow pattern for inviscid, irrotational flow
past a cylinder of infinite length. The fluid approaching the cylinder has a steady and uniform velocity of
v∞ in the x direction. Laplace's equation (3.9-10) can be converted to cylindrical coordinates to give

Equation 3.9-16

where the velocity components are given by

Equation 3.9-17

Using four boundary conditions which are needed and the method of separation of variables, the stream
function ψ is obtained. Converting to rectangular coordinates,
Equation 3.9-18

where R is the cylinder radius. The streamlines and the constant-velocity-potential lines are plotted in
Fig. 3.9-2 as a flow net.

Figure 3.9-2. Streamlines (ψ = constant) and constant velocity potential lines (ϕ  = constant) for the steady
and irrotational flow of an inviscid and incompressible fluid about an infinite circular cylinder.

EXAMPLE 3.9-2. Stream Function for a Flow Field
The velocity components for a flow field are as follows:

Prove that it satisfies the conservation of mass and determine ψ.

S olu t ion: First we determine ∂vx/∂x = 2ax and ∂vy /∂y = -2ax. Substituting these values into


Eq. (3.6-24), the conservation of mass for two-dimensional flow,

Then using Eq. (3.9-1),

Equation 3.9-19
Integrating Eq. (3.9-19) for vx,

Equation 3.9-20

Integrating Eq. (3.9-19) for vy ,

Equation 3.9-21

Equating Eq. (3.9-20) to (3.9-21),

Equation 3.9-22

Canceling like terms,

Equation 3.9-23

Hence, f(x) = 0 and f(y) = a y 3 /3. Substituting f(x) = 0 into Eq. (3.9-20),

Equation 3.9-24

EXAMPLE 3.9-3. Stream Function and Velocities from
Potential Function
The potential function for a two-dimensional, irrotational, incompressible flow field is given as
ϕ = x2 − 2y - y 2. Find the stream function ψ and the velocity components vx and  v y .

S olu t ion: Using Eqs. (3.9-1) and (3.9-5),

Combining,

Equation 3.9-25

Differentiating the potential function with respect to x and equating the result to ∂ψ/∂y  from
Eq. (3.9-25),

Equation 3.9.26

Differentiating the potential function with respect to y  and equating the result to -∂ψ/∂x
from Eq. (3.9-25),

Equation 3.9-27

Integrating Eq. (3.9-26),

Equation 3.9-28

Integrating Eq. (3.9-27),

Equation 3.9-29

Equating Eq. (3.9-28) to (3.9-29),
Equation 3.9-30

Hence, after canceling 2xy from both sides,

Equation 3.9-31

Therefore, f(x) = 2x and f(y) = 0. Substituting f(x) = 2x into Eq. (3.9-28),

Equation 3.9-32

The velocities are, from Eqs. (3.9-26) and (3.9-27),

Equation 3.9-33

In potential flow, the stream function and potential function are used to represent the flow in
the main body of the fluid. These ideal fluid solutions do not satisfy the condition that νx = νy
= 0 on the wall surface. Near the wall we have viscous drag and we use boundary-layer theory,
where we obtain approximate solutions for the velocity profiles in this thin boundary layer
taking into account viscosity. This is discussed in Section 3.10. Then we splice this solution
onto the ideal flow solution that describes flow outside the boundary layer.

3.9 E. Diffe r e ntial Eq u ations of M otion for  C r e e p ing Flow

At very low Reynolds numbers, below about 1, the term creeping flow is used to describe flow at very low
velocities. This type of flow applies for the fall or settling of small particles through a fluid. Stokes' law is
derived using this type of flow in problems of settling and sedimentation.

In flow around a sphere, for example, the fluid changes velocity and direction in a complex manner. If the
inertia effects in this case were important, it would be necessary to keep all the terms in the three Navier-
Stokes equations. Experiments show that at a Reynolds number below about 1, the inertia effects are
small and can be omitted. Hence, the equations of motion, Eqs. (3.7-36)-(3.7-38) for creeping flow of an
incompressible fluid, become

Equation 3.9-34
Equation 3.9-35

Equation 3.9-36

For flow past a sphere the stream function ψ can be used in the Navier-Stokes equation in spherical
coordinates to obtain the equation for the stream function and the velocity distribution and pressure
distribution over the sphere. Then by integration over the whole sphere, the form drag, caused by the
pressure distribution, and the skin friction or viscous drag, caused by the shear stress at the surface, can
be summed to give the total drag:

Equation 3.9-37

where FD is total drag force in N, Dp is particle diameter in m, ν is free stream velocity of fluid
approaching the sphere in m/s, and μ is viscosity in kg/m · s. This is Stokes' equation for the drag force
on a sphere.

Often Eq. (3.9-37) is rewritten as follows:

Equation 3.9-38

where C D is a drag coefficient, equal to 24/NRe for Stokes' law, and A is the projected area of the sphere, 
. This is discussed in more detail in Section 3.1 for flow past spheres.
                             
                                                 
                                             
                                               
     

3.10. BOUNDARY­LAYER FLOW AND TURBULENCE

3.10A. Bou nd ar y-Laye r  Flow

In Sections 3.8 and 3.9, the Navier-Stokes equations were used to find relations that described laminar
flow between flat plates and inside circular tubes, flow of ideal fluids, and creeping flow. In this section
the flow of fluids around objects will be considered in more detail, with particular attention being given
to the region close to the solid surface, called the boundary layer.

In the boundary-layer region near the solid, the fluid motion is greatly affected by this solid surface. In
the bulk of the fluid away from the boundary layer, the flow can often be adequately described by the
theory of ideal fluids with zero viscosity. However, in the thin boundary layer, viscosity is important.
Since the region is thin, simplified solutions can be obtained for the boundary-layer region. Prandtl
originally suggested this division of the problem into two parts, which has been used extensively in fluid
dynamics.

In order to help explain boundary layers, an example of boundary-layer formation in the steady-state
flow of a fluid past a flat plate is given in Fig. 3.10-1. The velocity of the fluid upstream of the leading
edge at x = 0 of the plate is uniform across the entire fluid stream and has the value v∞. The velocity of
the fluid at the interface is zero and the velocity vx in the x direction increases as one goes farther from the
plate. The velocity vx approaches asymptotically the velocity v∞ of the bulk of the stream.

Figure 3.10-1. Boundary layer for flow past a flat plate.

The dashed line L is drawn so that the velocity at that point is 99% of the bulk velocity v∞. The layer or
zone between the plate and the dashed line constitutes the boundary layer. When the flow is laminar, the

thickness δ of the boundary layer increases with   as we move in the x direction. The Reynolds number
is defined as NRe,x = xv∞ρ/μ, where x is the distance downstream from the leading edge. When the

Reynolds number is less than 2 × 105, the flow is laminar, as shown in Fig. 3.10-1.
The transition from laminar to turbulent flow on a smooth plate occurs in the Reynolds-number range 2
× 105 to 3 × 106, as shown in Fig. 3.10-1. When the boundary layer is turbulent, a thin, viscous sublayer
persists next to the plate. The drag caused by the viscous shear in the boundary layers is called skin
friction and is the only drag present for flow past a flat plate.

The type of drag occurring when fluid flows by a bluff or blunt shape such as a sphere or cylinder, which
is mostly caused by a pressure difference, is termed form drag. This drag predominates in flow past such
objects at all except low values of the Reynolds number, and often a wake is present. Skin friction and
form drag both occur in flow past a bluff shape, and the total drag is the sum of the skin friction and the
form drag. (See also Section 3.1A.)

3.10B. Bou nd ar y-Laye r  S e p ar ation and  For m ation of W ake s

We discussed the growth of the boundary layer at the leading edge of a plate as shown in Fig. 3.10-2.
However, some important phenomena also occur at the trailing edge of this plate and other objects. At
the trailing edge or rear edge of the flat plate, the boundary layers are present at the top and bottom sides
of the plate. On leaving the plate, the boundary layers gradually intermingle and disappear.

Figure 3.10-2. Flow perpendicular to a flat plate and boundarylayer separation.

If the direction of flow is at right angles to the plate, as shown in Fig. 3.10-2, a boundary layer forms as
before in the fluid that is flowing over the upstream face. Once at the edge of the plate, however, the
momentum in the fluid prevents it from making the abrupt turn around the edge of the plate, and it
separates from the plate. A zone of decelerated fluid is present behind the plate and large eddies
(vortices), called the wake, are formed in this area. The eddies consume large amounts of mechanical
energy. This separation of boundary layers occurs when the change in velocity of the fluid flowing past an
object is too large in direction or magnitude for the fluid to adhere to the surface.

Since formation of a wake causes large losses in mechanical energy, it is often necessary to minimize or
prevent boundary-layer separation by streamlining the objects or by other means. This is also discussed
in Section 3.1A for flow past immersed objects.

3.10C . Lam inar  Flow  and  Bou nd ar y-Laye r  The or y

1. Bou nd a r y -la y er  eq u a t ions

When laminar flow is occurring in a boundary layer, certain terms in the Navier-Stokes equations become
negligible and can be neglected. The thickness of the boundary layer δ is arbitrarily taken as the distance
away from the surface where the velocity reaches 99% of the free stream velocity. The concept of a
relatively thin boundary layer leads to some important simplifications of the Navier-Stokes equations.

For two-dimensional laminar flow in the x and y  directions of a fluid having a constant density, Eqs.
(3.7-36) and (3.7-37) become as follows for flow at steady state as shown in Figure 3.10-1 when we
neglect the body forces g x and g y :

Equation 3.10-1

Equation 3.10-2

The continuity equation for two-dimensional flow becomes

Equation 3.10-3

In Eq. (3.10-1), the term (μ/ρ)(∂ 2νx/∂x2) is negligible in comparison with the other terms in the
equation. Also, it can be shown that all the terms containing νy  and its derivatives are small. Hence, the
final two boundary-layer equations to be solved are Eqs. (3.10-3) and (3.10-4):

Equation 3.10-4

2. S olu t ion for  la mina r  b ou nd a r y  la y er  on a  fla t  p la t e

An important case in which an analytical solution has been obtained for the boundary-layer equations is
for the laminar boundary layer on a flat plate in steady flow, as shown in Fig. 3.10-1. A further
simplification can be made in Eq. (3.10-4) in that dp/dx is zero since v∞ is constant.

The final boundary-layer equations reduce to the equation of motion for the x direction and the
continuity equation as follows:

Equation 3.10-5
Equation 3.10-3

The boundary conditions are νx = νy  = 0 at y = 0 (y is distance from plate), and νx = v∞ at y = ∞.

The solution of this problem for laminar flow over a flat plate giving νx and νy  as a function of x and y
was first obtained by Blasius and later elaborated by Howarth (B1, B2, S3). The mathematical details of
the solution are quite tedious and complex and will not be given here. The general procedure will be
outlined. Blasius reduced the two equations to a single ordinary differential equation which is nonlinear.
The equation could not be solved to give a closed form, but a series solution was obtained.

The results of the work by Blasius are given as follows. The boundary-layer thickness δ, where νx ≅
0.99v∞, is given approximately by

Equation 3.10-6

where NRe,x = xν∞ρ/μ. Hence, the thickness δ varies as 

The drag in flow past a flat plate consists only of skin friction and is calculated from the shear stress at
the surface at y = 0 for any x as follows:

Equation 3.10-7

From the relation of νx as a function of x and y obtained from the series solution, Eq. (3.10-7) becomes

Equation 3.10-8
The total drag is given by the following for a plate of length L and width b:

Equation 3.10-9

Substituting Eq. (3.10-8) into (3.10-9) and integrating,

Equation 3.10-10

The drag coefficient C D related to the total drag on one side of the plate having an area A = bL is defined
as

Equation 3.10-11

Substituting the value for A and Eq. (3.10-10) into (3.10-11),

Equation 3.10-12

where NRe,L = Lv∞ρ/μ. A form of Eq. (3.10-11) is used in Section 14.3 for particle movement through a
fluid. The definition of C D in Eq. (3.10-12) is similar to the Fanning friction factor f for pipes.

The equation derived for C D applies to the laminar boundary layer only for NRe,L less than about 5 × 105.
Also, the results are valid only for positions where x is sufficiently far from the leading edge so that x or L
is much greater than δ. Experimental results on the drag coefficient to a flat plate confirm the validity of
Eq. (3.10-12). Boundary-layer flow past many other shapes has been successfully analyzed using similar
methods.

3.10D. Natu r e  and  Inte nsity of Tu r b u le nce

1. Na t u r e of t u r b u lence

Since turbulent flow is important in many areas of engineering, the nature of turbulence has been
extensively investigated. Measurements of the velocity fluctuations of the eddies in turbulent flow have
helped explain turbulence.
For turbulent flow there are no exact solutions of flow problems as there are in laminar flow, since the
approximate equations used depend on many assumptions. However, useful relations have been
obtained by combining experimental data and theory. Some of these relations will be discussed.

Turbulence can be generated by contact between two layers of fluid moving at different velocities or by a
flowing stream in contact with a solid boundary, such as a wall or sphere. When a jet of fluid from an
orifice flows into a mass of fluid, turbulence can arise. In turbulent flow at a given place and time, large
eddies are continually being formed which break down into smaller eddies and finally disappear. Eddies
can be as small as about 0.1-1 mm and as large as the smallest dimension of the turbulent stream. Flow
inside an eddy is laminar because of its large size.

In turbulent flow the velocity is fluctuating in all directions. In Fig. 3.10-3 a typical plot of the variation
of the instantaneous velocity νx in the x direction at a given point in turbulent flow is shown. The velocity

 is the deviation of the velocity from the mean velocity   in the x direction of flow of the stream.
Similar relations also hold for the y and z directions:

Equation 3.10-13

Equation 3.10-14

Figure 3.10-3. Velocity fluctuations in turbulent flow.

where the mean velocity   is the time-averaged velocity for time t, νx the instantaneous total velocity
in the x direction, and   the instantaneous deviating or fluctuating velocity in the x direction. These

fluctuations can also occur in the y  and z directions. The value of   fluctuates about zero as an average

and, hence, the time-averaged values  . However, the values of 

, will not be zero. Similar expressions can also be written for pressure, which also
fluctuates.

2. Int ensit y  of t u r b u lence

The time average of the fluctuating components vanishes over a time period of a few seconds. However,
the time average of the mean square of the fluctuating components is a positive value. Since the
fluctuations are random, the data have been analyzed by statistical methods. The level or intensity of
turbulence can be related to the square root of the sum of the mean squares of the fluctuating
components. This intensity of turbulence is an important parameter in the testing of models and the
theory of boundary layers. The intensity of turbulence I can be defined mathematically as

Equation 3.10-15

This parameter I is quite important. Such factors as boundary-layer transition, separation, and heat- and
mass-transfer coefficients depend upon the intensity of turbulence. Simulation of turbulent flows in
testing of models requires that the Reynolds number and the intensity of turbulence be the same. One
method used to measure intensity of turbulence is to utilize a hot-wire anemometer.

3.10E. Tu r b u le nt S he ar  or  R e ynold s S tr e sse s

In a fluid flowing in turbulent flow, shear forces occur wherever there is a velocity gradient across a shear
plane, and these are much larger than those occurring in laminar flow. The velocity fluctuations in Eq.
(3.10-13) give rise to turbulent shear stresses. The equations of motion and the continuity equation are
still valid for turbulent flow. For an incompressible fluid having a constant density ρ  and viscosity μ, the
continuity equation (3.6-24) holds:

Equation 3.6-24

Also, the x component of the equation of motion, Eq. (3.7-36), can be written as follows if Eq. (3.6-24)
holds:

Equation 3.10-16

[View full size image]

We can rewrite the continuity equation (3.6-24) and Eq. (3.10-16) by replacing νx by 

Equation 3.10-17

Equation 3.10-18

[View full size image]

Now we use the fact that the time-averaged value of the fluctuating velocities is zero 

, and that the time-averaged product   is not zero. Then Eqs. (3.10-17)
and (3.10-18) become

Equation 3.10-19

Equation 3.10-20

[View full size image]

By comparing these two time-smoothed equations with Eqs. (3.6-24) and (3.10-16), we see that the
time-smoothed values everywhere replace the instantaneous values. However, in Eq. (3.10-20) new
terms arise in the set of brackets which are related to turbulent velocity fluctuations. For convenience we
use the notation

Equation 3.10-21

These are the components of the turbulent momentum flux and are called Reynolds stresses.

3.10F. Pr and tl M ixing Le ngth

The equations derived for turbulent flow must be solved to obtain velocity profiles. To do this, more
simplifications must be made before the expressions for the Reynolds stresses can be evaluated. A
number of semiempirical equations have been used; the eddy-diffusivity model of Boussinesq is one early
attempt to evaluate these stresses. By analogy to the equation for shear stress in laminar flow, τyx = -μ(
dvx/dy), the turbulent shear stress can be written as

Equation 3.10-22

where η t  is a turbulent or eddy viscosity, which is a strong function of position and flow. This equation
can also be written as follows:

Equation 3.10-23

where εt = ηt/ρ is eddy diffusivity of momentum in m2/s, by analogy to the momentum diffusivity μ/ρ
for laminar flow.

In his mixing-length model Prandtl developed an expression to evaluate these stresses by assuming that
eddies move in a fluid in a manner similar to the movement of molecules in a gas. The eddies move a
distance called the mixing length L before they lose their identity.

Actually, the moving eddy or "lump" of fluid will gradually lose its identity. However, in the definition of
the Prandtl mixing length L, this small packet of fluid is assumed to retain its identity while traveling
the entire length L and then lose its identity or be absorbed in the host region.

Prandtl assumed that the velocity fluctuation   is due to a "lump" of fluid moving a distance L in the y
direction and retaining its mean velocity. At point L, the lump of fluid will differ in mean velocity from
the adjacent fluid by   Then the value of   is

Equation 3.10-24

The length L is small enough that the velocity difference can be written as

Equation 3.10-25

Hence,

Equation 3.10-26

Prandtl also assumed   Then the time average,   is

Equation 3.10-27

The minus sign and the absolute value were used to make the quantity   agree with experimental
data. Substituting Eq. (3.10-27) into (3.10-21),

Equation 3.10-28

Comparing with Eq. (3.10-23),
Equation 3.10-29

3.10G . Univ e r sal Ve locity Distr ib u tion in Tu r b u le nt Flow

To determine the velocity distribution for turbulent flow at steady state inside a circular tube, we divide
the fluid inside the pipe into two regions: a central core where the Reynolds stress approximately equals
the shear stress; and a thin, viscous sublayer adjacent to the wall where the shear stress is due only to
viscous shear and the turbulence effects are assumed negligible. Later we include a third region, the
buffer zone, where both stresses are important.

Dropping the subscripts and superscripts on the shear stresses and velocity, and considering the thin,
viscous sublayer, we can write

Equation 3.10-30

where τ0 is assumed constant in this region. On integration,

Equation 3.10-31

Defining a friction velocity as follows and substituting into Eq. (3.10-31),

Equation 3.10-32

Equation 3.10-33

The dimensionless velocity ratio on the left can be written as

Equation 3.10-34
The dimensionless number on the right can be written as

Equation 3.10-35

where y  is the distance from the wall of the tube. For a tube of radius r 0, y = r 0 - r, where r  is the distance


from the center. Hence, for the viscous sublayer, the velocity distribution is

Equation 3.10-36

Next, considering the turbulent core where any viscous stresses are neglected, Eq. (3.10-28) becomes

Equation 3.10-37

where dv/dy is always positive and the absolute value sign is dropped. Prandtl assumed that the mixing
length is proportional to the distance from the wall, or

Equation 3.10-38

and that τ = τ0 = constant. Equation (3.10-37) now becomes

Equation 3.10-39
Hence,

Equation 3.10-40

Upon integration,

Equation 3.10-41

where K1 is a constant. The constant K1 can be found by assuming that ν is zero at a small value of y, say
y 0:

Equation 3.10-42

Introducing the variable y +  by multiplying the numerator and denominator of the term y/y 0 by ν*/ν,


where ν = μ/ρ, we obtain

Equation 3.10-43

Equation 3.10-44

A large amount of velocity distribution data by Nikuradse and others for a range of Reynolds numbers of
4000 to 3.2 × 106 have been obtained, and the data fit Eq. (3.10-36) in the region up to y + of 5 and also fit
Eq. (3.10-44) above y + of 30, with K and C 1 being universal constants. For the region of y + from 5 to 30,
which is defined as the buffer region, an empirical equation of the form of Eq. (3.10-44) fits the data. In
Fig. 3.10-4 the following relations which are valid are plotted to give a universal velocity profile for fluids
flowing in smooth, circular tubes:

Equation 3.10-45
Equation 3.10-46

Equation 3.10-47

Figure 3.10-4. Universal velocity profile for turbulent flow in smooth circular tubes.

Three distinct regions are apparent in Fig. 3.10-4. The first region next to the wall is the viscous sublayer
(historically called "laminar" sublayer), given by Eq. (3.10-45), where the velocity is proportional to the
distance from the wall. The second region, called the buffer layer, is given by Eq. (3.10-46), and is a
region of transition between the viscous sublayer with practically no eddy activity and the violent eddy
activity in the turbulent core region given by Eq. (3.10-47). These equations can then be used and related
to the Fanning friction factor discussed earlier in this chapter. They can also be used in solving turbulent
boundary-layer problems.

3.10H. Inte gr al M om e ntu m  Balance  for  Bou nd ar y-Laye r  Analysis

1. Int r od u ct ion a nd  d er iv a t ion of int eg r a l exp r ession

In the solution for the laminar boundary layer on a flat plate, the Blasius solution is quite restrictive,
since it is only for laminar flow over a flat plate. Other, more complex systems cannot be solved by this
method. An approximate method developed by von Kármán can be used when the configuration is more
complicated or the flow is turbulent. This is an approximate momentum integral analysis of the
boundary layer using an empirical or assumed velocity distribution.

In order to derive the basic equation for a laminar or turbulent boundary layer, a small control volume in
the boundary layer on a flat plate is used, as shown in Fig. 3.10-5. The depth in the z direction is b. Flow
is only through the surfaces A1 and A 2  and also from the top curved surface at δ. An overall integral
momentum balance using Eq. (2.8-8) and overall integral mass balance using Eq. (2.6-6) are applied to
the control volume inside the boundary layer at steady state, and the final integral expression by von
Kármán is (B2, S3)

Equation 3.10-48

Figure 3.10-5. Control volume for integral analysis of the boundary-layer flow.

where τ0 is the shear stress at the surface y  = 0 at point x along the plate. Also, δ and τ0 are functions of
x.

Equation (3.10-48) is an expression whose solution requires knowledge of the velocity νx as a function of
the distance from the surface, y . The accuracy of the results will, of course, depend on how closely the
assumed velocity profile approaches the actual profile.

2. Int eg r a l moment u m b a la nce for  la mina r  b ou nd a r y  la y er

Before we use Eq. (3.10-48) for the turbulent boundary layer, this equation will be applied to the laminar
boundary layer over a flat plate so that the results can be compared with the exact Blasius solution in
Eqs. (3.10-6)-(3.10-12).

In this analysis certain boundary conditions must be satisfied in the boundary layer:
Equation 3.10-49

The conditions above are fulfilled in the following simple, assumed velocity profile:

Equation 3.10-50

The shear stress τ0 at a given x can be obtained from

Equation 3.10-51

Differentiating Eq. (3.10-50) with respect to y and setting y = 0,

Equation 3.10-52

Substituting Eq. (3.10-52) into (3.10-51),

Equation 3.10-53

Substituting Eq. (3.10-50) into Eq. (3.10-48) and integrating between y = 0 and y = δ, we obtain

Equation 3.10-54
Combining Eqs. (3.10-53) and (3.10-54) and integrating between δ = 0 and δ = δ, and x = 0 and x = L,

Equation 3.10-55

where the length of plate is x = L. Proceeding in a manner similar to Eqs. (3.10-6)-(3.10-12), the drag
coefficient is

Equation 3.10-56

A comparison of Eq. (3.10-6) with (3.10-55) and (3.10-12) with (3.10-56) shows the success of this
method. Only the numerical constants differ slightly. This method can be used with reasonable accuracy
for cases where an exact analysis is not feasible.

3. Int eg r a l moment u m a na ly sis for  t u r b u lent  b ou nd a r y  la y er

The procedures used for the integral momentum analysis for a laminar boundary layer can be applied to
the turbulent boundary layer on a flat plate. A simple empirical velocity distribution for pipe flow which
is valid up to a Reynolds number of 105 can be adapted for the boundary layer on a flat plate, to become

Equation 3.10-57

This is the Blasius  -power law, which is often used.

Equation (3.10-57) is substituted into the integral relation equation (3.10-48):

Equation 3.10-58
The power-law equation does not hold, as y goes to zero at the wall. Another useful relation is the Blasius
correlation for shear stress for pipe flow, which is consistent at the wall for the wall shear stress τ0. For
boundary-layer flow over a flat plate, it becomes

Equation 3.10-59

Integrating Eq. (3.10-58), combining the result with Eq. (3.10-59), and integrating between δ = 0 and δ =
δ, and x = 0 and x = L,

Equation 3.10-60

Integration of the drag force as before gives

Equation 3.10-61

In this development the turbulent boundary layer was assumed to extend to x = 0. Actually, a certain
length at the front has a laminar boundary layer. Experimental data agree with Eq. (3.10-61) reasonably
well from a Reynolds number of 5 × 105 to 107 . More-accurate results at higher Reynolds numbers can be
obtained by using a logarithmic velocity distribution, Eqs. (3.10-45)-(3.10-47).
                             
                                                 
                                             
                                               
     

3.11. DIMENSIONAL ANALYSIS IN MOMENTUM TRANSFER

3.11A. Dim e nsional Analysis of Diffe r e ntial Eq u ations

In this chapter we have derived several differential equations describing various flow situations.
Dimensional homogeneity requires that every term in a given equation have the same units. Then, the
ratio of one term in the equation to another term is dimensionless. Knowing the physical meaning of each
term in the equation, we are then able to give a physical interpretation to each of the dimensionless
parameters or numbers formed. These dimensionless numbers, such as the Reynolds number and others,
are useful in correlating and predicting transport phenomena in laminar and turbulent flow.

Often it is not possible to integrate the differential equation describing a flow situation. However, we can
use the equation to find out which dimensionless numbers can be used in correlating experimental data
for this physical situation.

An important example of this involves the use of the Navier-Stokes equation, which often cannot be
integrated for a given physical situation. To start, we use Eq. (3.7-36) for the x component of the Navier-
Stokes equation. At steady state this becomes

Equation 3.11-1

Each term in this equation has the units length/time2, or L/t 2.

In this equation each term has a physical significance. First we use a single characteristic velocity v and a
single characteristic length L for all terms. Then the expression of each term in Eq. (3.11-1) is as follows:
The left-hand side can be expressed as v2/L and the right-hand terms, respectively, as g, p/ρL, and μv/
ρL2. We then write

Equation 3.11-2

This expresses a dimensional equality and not a numerical equality. Each term has dimensions L/t 2.

The left-hand term in Eq. (3.11-2) represents the inertia force and the terms on the right-hand side
represent, respectively, the gravity force, pressure force, and viscous force. Dividing each of the terms in
Eq. (3.11-2) by the inertia force [v 2/L], the following dimensionless groups or their reciprocals are
obtained:
Equation 3.11-3

Equation 3.11-4

Equation 3.11-5

Note that this method not only gives the various dimensionless groups for a differential equation but also
gives physical meaning to these dimensionless groups. The length, velocity, and so forth to be used in a
given case will be that value which is most significant. For example, the length may be the diameter of a
sphere, the length of a flat plate, and so on.

Systems that are geometrically similar are said to be dynamically similar if the parameters representing
ratios of forces pertinent to the situation are equal. This means that the Reynolds, Euler, or Froude
numbers must be equal between the two systems.

This dynamic similarity is an important requirement in obtaining experimental data for a small model
and extending these data to scale up to the large prototype. Since experiments with full-scale prototypes
would often be difficult and/or expensive, it is customary to study small models. This is done in the
scale-up of chemical process equipment and in the design of ships and airplanes.

3.11B. Dim e nsional Analysis Using the  Bu ckingham  M e thod

The method of obtaining the important dimensionless numbers from the basic differential equations is
generally the preferred method. In many cases, however, we are not able to formulate a differential
equation which clearly applies. Then a more general procedure is required, known as the Buckingham
method. In this method the listing of the important variables in the particular physical problem is done
first. Then we determine the number of dimensionless parameters into which the variables may be
combined by using the Buckingham pi theorem.

The Buckingham theorem states that the functional relationship among q quantities or variables whose
units may be given in terms of u  fundamental units or dimensions may be written as (q − u)
independent dimensionless groups, often called π's. [This quantity u  is actually the maximum number
of these variables that will not form a dimensionless group. However, only in a few cases is u  not equal to
the number of fundamental units (B1).]

Let us consider the following example, to illustrate the use of this method. An incompressible fluid is
flowing inside a circular tube of inside diameter D. The significant variables are pressure drop Δp,
velocity v, diameter D, tube length L, viscosity μ, and density ρ . The total number of variables is q = 6.
The fundamental units or dimensions are u = 3 and are mass M , length L, and time t. The units of the
variables are as follows: Δp in M/Lt 2, v in L/t, D in L, L in L, μ in M/Lt, and ρ  in M/L 3 . The number of
dimensionless groups or π's is q − u, or 6  − 3 = 3. Thus,

Equation 3.11-6

Next, we must select a core group of u (or 3) variables which will appear in each π group and among them
contain all the fundamental dimensions. Also, no two of the variables selected for the core can have the
same dimensions. In choosing the core, the variable whose effect one desires to isolate is often excluded
(for example, Δp). This leaves us with the variables ν, D, μ and ρ to be used. (L and D have the same
dimensions.)

We will select D, ν, and ρ to be the core variables common to all three groups. Then the three
dimensionless groups are

Equation 3.11-7

Equation 3.11-8

Equation 3.11-9

To be dimensionless, the variables must be raised to certain exponents a, b, c, and so forth. First we
consider the π1 group:

Equation 3.11-7

To evaluate these exponents, we write Eq. (3.11-7) dimensionally by substituting the dimensions for each
variable:

Equation 3.11-10
Next we equate the exponents of L on both sides of this equation, of M, and finally of t:

Equation 3.11-11

Solving these equations, a = 0, b = −2, and c = −1. Substituting these values into Eq. (3.11-7),

Equation 3.11-12

Repeating this procedure for π2 and π3,

Equation 3.11-13

Equation 3.11-14

Finally, substituting π1, π2, and π3 into Eq. (3.11-6),

Equation 3.11-15

Combining Eq. (2.10-5) with the left-hand side of Eq. (3.11-15), the result obtained shows that the
friction factor is a function of the Reynolds number (as was shown before in the empirical correlation of
friction factor and Reynolds number) and of the length/diameter ratio. In pipes with L/D >> 1 or pipes
with fully developed flow, the friction factor is found to be independent of L/D.

This type of analysis is useful in empirical correlations of data. However, it does not tell us the
importance of each dimensionless group, which must be determined by experimentation, nor does it
select the variables to be used.
                             
                                                 
                                             
                                               
     

PROBLEMS
3.1-1.
For ce on a  C y lind er  in a  W ind  Tu nnel. Air at 101.3 kPa absolute and 25°C is flowing at a
velocity of 10 m/s in a wind tunnel. A long cylinder having a diameter of 90 mm is placed in the
tunnel and the axis of the cylinder is held perpendicular to the air flow. What is the force on the
cylinder per meter length?
A1:Ans. C D = 1.3, FD = 6.94 N
3.1-2.
W ind  For ce on a  S t ea m Boiler  S t a ck . A cylindrical steam boiler stack has a diameter of 1.0
m and is 30.0 m high. It is exposed to a wind at 25°C having a velocity of 50 miles/h. Calculate
the force exerted on the boiler stack.
A2:Ans. C D = 0.33, FD = 2935 N
3.1-3.
Effect  of Velocit y  on For ce on a  S p he r e a nd  S t ok es' La w . A sphere having a diameter of
0.042 m is held in a small wind tunnel, where air at 37.8°C and 1 atm abs and various velocities
is forced past it.

a.  Determine the drag coefficient and force on the sphere for a velocity of 2.30 × 10−4 m/s.
Use Stokes' law here if it is applicable.

b.  Also determine the force for velocities of 2.30 × 10−3, 2.30 × 10-2, 2.30 × 10−1, and 2.30
m/s. Make a plot of FD versus velocity

3.1-4 .
Dr a g  For ce on Br id g e Pier  in R iv er . A cylindrical bridge pier 1.0 m in diameter is
submerged to a depth of 10 m. Water in the river at 20°C is flowing past at a velocity of 1.2 m/s.
Calculate the force on the pier.
3.1-5.
S u r fa ce Ar ea  in a  Pa ck ed  Bed . A packed bed is composed of cubes 0.020 m on a side and the
bulk density of the packed bed is 980 kg/m3. The density of the solid cubes is 1500 kg/m3.

a.  Calculate ε, effective diameter Dp, and a.

b.  Repeat for the same conditions but for cylinders having a diameter of D = 0.02 m and a
length h = 1.5D.

A5: Ans.  (a) ε = 0.3467, D  = 0.020 m, a  = 196.0 m−1


p
3.1-6 .
Der iv a t ion for  Nu mb er  of Pa r t icles in a  Bed  of C y lind er s. For a packed bed containing
cylinders, where the diameter D of the cylinders is equal to the length h, do as follows for a bed
having a void fraction ε:

a.  Calculate the effective diameter.

b.  Calculate the number of cylinders, n, in 1 m3 of the bed.
A6 :Ans. (a) Dp = D
3.1-7.
Der iv a t ion of Dimensionless Eq u a t ion for  Pa ck ed  Bed . Starting with Eq. (3.1-20), derive
the dimensionless equation (3.1-21). Show all steps in the derivation.
3.1-8.
Flow  a nd  Pr essu r e Dr op  of G a ses in Pa ck ed  Bed . Air at 394.3 K flows through a packed
bed of cylinders having a diameter of 0.0127 m and length the same as the diameter. The bed
void fraction is 0.40 and the length of the packed bed is 3.66 m. The air enters the bed at 2.20
atm abs at the rate of 2.45 kg/m2 · s based on the empty cross section of the bed. Calculate the
pressure drop of air in the bed.
A8: Ans.  Δp = 0.1547 × 105 Pa
3.1-9 .
Flow  of W a t er  in a  Filt er  Bed . Water at 24°C is flowing by gravity through a filter bed of
small particles having an equivalent diameter of 0.0060 m. The void fraction of the bed is
measured as 0.42. The packed bed has a depth of 1.50 m. The liquid level of water above the bed
is held constant at 0.40 m. What is the water velocity ν' based on the empty cross section of the
bed?
3.1-10.
M ea n Dia met er  of Pa r t icles in Pa ck ed  Bed . A mixture of particles in a packed bed contains
the following volume percent of particles and sizes: 15%, 10 mm; 25%, 20 mm; 40%, 40 mm;
20%, 70 mm. Calculate the effective mean diameter, Dpm, if the shape factor is 0.74.
A10:Ans. Dpm = 18.34 mm
3.1-11.
Per mea b ilit y  a nd  Da r cy 's La w . A sample core of porous rock obtained from an oil reservoir
is 8 cm long and has a diameter of 2.0 cm. It is placed in a core holder. With a pressure drop of
1.0 atm, the water flow at 20.2°C through the core is measured as 2.60 cm3/s. What is the
permeability in darcy?
3.1-12.
M inimu m Flu id iza t ion a nd  Exp a nsion of Flu id  Bed . Particles having a size of 0.10 mm,
a shape factor of 0.86, and a density of 1200 kg/m3 are to be fluidized using air at 25°C and
202.65 kPa abs pressure. The void fraction at minimum fluidizing conditions is 0.43. The bed
diameter is 0.60 m and the bed contains 350 kg of solids.

a.  Calculate the minimum height of the fluidized bed.

b.  Calculate the pressure drop at minimum fluidizing conditions.

c.  Calculate the minimum velocity for fluidization.

d.  Using 4.0 times the minimum velocity, estimate the porosity of the bed.

A12:  (a)   = 1.810 m; (b) Δ  = 0.1212 × 10  Pa; (c)   = 0.004374 m/s; (d)   = 0.604

Ans. Lmf p 5 ε
3.1-13.
M inimu m Flu id iza t ion Velocit y  Using  a  Liq u id . A tower having a diameter of 0.1524 m is
being fluidized with water at 20.2°C. The uniform spherical beads in the tower bed have a
diameter of 4.42 mm and a density of 1603 kg/m3. Estimate the minimum fluidizing velocity
and compare with the experimental value of 0.02307 m/s found by Wilhelm and Kwauk (W5).
3.1-14 .
Flu id iza t ion of a  S a nd -Bed  Filt er . To clean a sand-bed filter, it is fluidized at minimum
conditions using water at 24°C. The round sand particles have a density of 2550 kg/m3 and an
average size of 0.40 mm. The sand has the properties given in Table 3.1-2.

a.  The bed diameter is 0.40 m and the desired height of the bed at these minimum fluidizing
conditions is 1.75 m. Calculate the amount of solids needed.

b.  Calculate the pressure drop at these conditions and the minimum velocity for
fluidization.

c.  Using 4.0 times the minimum velocity, estimate the porosity and height of the expanded
bed.

A14 : Ans.  (a) 325.2 kg solids; (b) 1.546 × 104 Pa


3.2-1.
Flow  M ea su r ement  Using  a  Pilot  Tu b e. A pitot tube is used to measure the flow rate of
water at 20°C in the center of a pipe having an inside diameter of 102.3 mm. The manometer
reading is 78 mm of carbon tetrachloride at 20°C. The pitot tube coefficient is 0.98.

a.  Calculate the velocity at the center and the average velocity.

b.  Calculate the volumetric flow rate of the water.

A15: Ans.  (a) ν  = 0.9372 m/s, ν  = 0.773 m/s; (b) 6.35 × 10−3 m3/s


max av
3.2-2.
G a s Flow  R a t e Using  a  Pit ot  Tu b e. The flow rate of air at 37.8°C is being measured at the
center of a duct having a diameter of 800 mm by a pitot tube. The pressure-difference reading on
the manometer is 12.4 mm of water. At the pitot-tube position, the static-pressure reading is 275
mm of water above 1 atm abs. The pitot-tube coefficient is 0.97. Calculate the velocity at the
center and the volumetric flow rate of the air.
3.2-3.
Pit ot -Tu b e Tr a v er se for  Flow -R a t e M ea su r ement . In a pitot-tube traverse of a pipe
having an inside diameter of 155.4 mm in which water at 20°C is flowing, the following data
were obtained:

Distance from Wall (mm) Reading in Manometer (mm of Carbon Tetrachloride)

26.9 122
52.3 142

77.7 157
103.1 137

128.5 112

The pitot-tube coefficient is 0.98.

a.  Calculate the maximum velocity at the center.

b.  Calculate the average velocity. [Hint: Use Eq. (2.6-17) and do a numerical or a graphical
integration.]

3.2-4 .
M et er ing  Flow  b y  a  Vent u r i. A venturi meter having a throat diameter of 38.9 mm is
installed in a line having an inside diameter of 102.3 mm. It meters water having a density of
999 kg/m3. The measured pressure drop across the venturi is 156.9 kPa. The venturi coefficient
C ν  is 0.98. Calculate the gal/min and m3/s flow rate.
A18: Ans.  330 gal/min, 0.0208 m3/s
3.2-5.
Use of a  Vent u r i t o M et er  W a t er  Flow . Water at 20°C is flowing in a 2-in. schedule 40 steel
pipe. Its flow rate is measured by a venturi meter having a throat diameter of 20 mm. The
manometer reading is 214 mm of mercury. The venturi coefficient is 0.98. Calculate the flow
rate.
3.2-6 .
M et er ing  of Oil Flow  b y  a n Or ifice. A heavy oil at 20°C having a density of 900 kg/m3 and
a viscosity of 6 cp is flowing in a 4-in. schedule 40 steel pipe. When the flow rate is 0.0174 m3/s,
it is desired to have a pressure-drop reading across the manometer equivalent to 0.93 × 105 Pa.
What size orifice should be used if the orifice coefficient is assumed as 0.61? What is the
permanent pressure loss?
3.2-7.
W a t er  Flow  R a t e in a n Ir r ig a t ion Dit ch. Water is flowing in an open channel in an
irrigation ditch. A rectangular weir having a crest length L = 1.75 ft is used. The weir head is
measured as h0 = 0.47 ft. Calculate the flow rate in ft 3/s and m3/s.
A21: Ans.  Flow rate = 1.776 ft 3/s, 0.0503 m3/s
3.2-8.
S izing  a  Flow  Nozzle. A flow nozzle is to be sized for use in a pipe having an internal diameter
of 1.25 in. to meter 0.60 ft 3/min of water at 25°C. A pressure drop of 10.0 in. of water is to be
used. Calculate the size of the flow nozzle and the permanent power loss in hp. Assume the
coefficient C n  = 0.96.
A22: Ans.  D  = 0.506 in., p  − p  =  37.38 lb /ft 2 (1.789 kPa)
2 1 4 f

3.3-1.
Br a k e Hor sep ow er  of C ent r ifu g a l Pu mp . Using Fig. 3.3-2 and a flow rate of 60 gal/min, do
as follows:

a.  Calculate the brake hp of the pump using water with a density of 62.4 lbm/ft 3. Compare


with the value from the curve.

b.  Do the same for a nonviscous liquid having a density of 0.85 g/cm3.

A23:Ans. (b) 0.69 brake hp (0.51 kW)
3.3-2.
k W  Pow er  of a  Fa n. A centrifugal fan is to be used to take a flue gas at rest (zero velocity) and
at a temperature of 352.6 K and a pressure of 749.3 mm Hg and discharge this gas at a pressure
of 800.1 mm Hg and a velocity of 38.1 m/s. The volume flow rate of gas is 56.6 std m3/min of
gas (at 294.3 K and 760 mm Hg). Calculate the brake kW of the fan if its efficiency is 65% and
the gas has a molecular weight of 30.7. Assume incompressible flow.
3.3-3.
Ad ia b a t ic C omp r ession of Air . A compressor operating adiabatically is to compress 2.83
m3/min of air at 29.4°C and 102.7 kN/m2 to 311.6 kN/m2. Calculate the power required if the
efficiency of the compressor is 75%. Also, calculate the outlet temperature.
3.3-4 .
(NPS H) R  for Feed  t o Dist illa t ion Tow er . A feed rate of 200 gpm of a hydrocarbon mixture
at 70°C is being pumped from a tank at 1 atm abs pressure to a distillation tower. The density of
the feed is 46.8 lbm/ft 3 and its vapor pressure is 8.45 psia. The velocity in the inlet line to the
pump is 3 ft/s and the friction loss between the tank and pump is 3.5 ft of fluid. The net positive
suction head required is 6 ft.

a.  How far below the liquid level in the tank must the pump be to obtain this required
(NPSH)R?

b.  If the feed is at the boiling point, calculate the pump position.

A26 :Ans. (a) z1 = −9.57 ft (−2.92 m)
3.4 -1.
Pow er  for  Liq u id  Ag it a t ion. It is desired to agitate a liquid having a viscosity of 1.5 × 10−3
Pa · s and a density of 969 kg/m3 in a tank having a diameter of 0.91 m. The agitator will be a
six-blade open turbine having a diameter of 0.305 m operating at 180 rpm. The tank has four
vertical baffles, each with a width J of 0.076 m. Also, W = 0.0381 m. Calculate the required kW.
Use curve 2, Fig. 3.4-4.
A27:Ans. NP = 2.5, power = 0.172 kW (0.231 hp)
3.4 -2.
Pow er  for  Ag it a t ion a nd  S ca le-Up . A turbine agitator having six flat blades and a disk has a
diameter of 0.203 m and is used in a tank having a diameter of 0.61 m and height of 0.61 m. The
width W = 0.0405 m. Four baffles are used having a width of 0.051 m. The turbine operates at
275 rpm in a liquid having a density of 909 kg/m3 and viscosity of 0.020 Pa · s.

a.  Calculate the kW power of the turbine and kW/m3 of volume.

b.  Scale up this system to a vessel having a volume of 100 times the original for the case of
equal mass transfer rates.

A28: Ans.  (a) P = 0.1508 kW, P/V =  0.845 kW/m3; (b) P  = 15.06 kW, P /V  = 0.845 kW/m3


2 2 2
3.4 -3.
S ca le-d ow n of Pr ocess Ag it a t ion S y st em. An existing agitation process operates using the
same agitation system and fluid as described in Example 3.4-1a. It is desired to design a small
pilot unit with a vessel volume of 2.0 liters so that effects of various process variables on the
system can be studied in the laboratory. The rates of mass transfer appear to be important in this
system, so the scale-down should be on this basis. Design the new system specifying sizes, rpm,
and kW power.
3.4 -4 .
Anchor  Ag it a t ion S y st em. An anchor-type agitator similar to that described for Eq. (3.4-3) is
to be used to agitate a fluid having a viscosity of 100 Pa · s and a density of 980 kg/m3. The
vessel size is Dt = 0.90 m and H = 0.90 m. The rpm is 50. Calculate the power required.
3.4 -5.
Desig n of Ag it a t ion S y st em. An agitation system is to be designed for a fluid having a
density of 950 kg/m3 and viscosity of 0.005 Pa · s. The vessel volume is 1.50 m3 and a standard
six-blade open turbine with blades at 45°C (curve 3, Fig. 3.4-4) is to be used with Da /W = 8 and

Da /Dt = 0.35. For the preliminary design a power of 0.5 kW/m3 volume is to be used. Calculate
the dimensions of the agitation system, rpm, and kW power.
3.4 -6 .S ca le-Up  of M ixing  Times for  a  Tu r b ine. For scaling up a turbine-agitated system, do as
follows:

a.  Derive Eq. (3.4-17) for the same power/unit volume.

b.  Derive Eq. (3.4-18) for the same mixing times.

3.4 -7.
M ixing  Time in a  Tu r b ine-Ag it a t ed  S y st em. Do as follows:

a.  Predict the time of mixing for the turbine system in Example 3.4-1a.

b.  Using the same system as part (a) but with a tank having a volume of 10.0 m3 and the
same power/unit volume, predict the new mixing time.

A33:Ans. (a) ft = 4.0, t T = 17.3 s

3.4 -8.
Effect  of Viscosit y  on M ixing  Time. Using the same conditions for the turbine mixer as in
Example 3.4-4, part (a), except for a viscous fluid with a viscosity of 100 Pa · s (100 000 cp),
calculate the mixing time. Compare this mixing time with that for the viscosity of 10 cp. Also
calculate the power per unit volume.
A34 :Ans. t T = 562 s
3.4 -9 .
M ixing  Time in a  Helica l M ixer . A helical mixer with an agitator pitch/tank diameter = 1.0
and with Dt = 1.83 m and Da /Dt = 0.95 is being used to agitate a viscous fluid having a viscosity

of 200 000 cp and a density of 950 kg/m3. The value of N = 0.3 rev/s. Calculate the mixing time
and the power per unit volume.
A35:Ans. t T = 420 s
3.5-1.
Pr essu r e Dr op  of Pow er -La w  Flu id , Ba na na  Pu r ée. A power-law biological fluid, banana
purée, is flowing at 23.9°C, with a velocity of 1.018 m/s, through a smooth tube 6.10 m long
having an inside diameter of 0.01267 m. The flow properties of the fluid are K = 6.00 N ·
s0.454/m2 and n = 0.454. The density of the fluid is 976 kg/m3.

a.  Calculate the generalized Reynolds number and also the pressure drop using Eq. (3.5-9).
Be sure to convert K to K' first.

b.  Repeat part (a), but use the friction factor method.

Ans.  (a) NRe,gen  = 63.6, Δp = 245.2 kN/m2 (5120 lbf/ft 2)


3.5-2.
Pr essu r e Dr op  of Pseu d op la st ic Flu id . A pseudoplastic power-law fluid having a density of
63.2 lbm/ft 3 is flowing through 100 ft of pipe having an inside diameter of 2.067 in. at an

average velocity of 0.500 ft/s. The flow properties of the fluid are K = 0.280 lbf · sn /ft 2 and n =


0.50. Calculate the generalized Reynolds number and also the pressure drop, using the friction
factor method.
3.5-3.
Tu r b u lent  Flow  of Non-New t onia n Flu id , Ap p lesa u ce. Applesauce having the flow
properties given in Table 3.5-1 is flowing in a smooth tube having an inside diameter of 50.8 mm
and a length of 3.05 m at a velocity of 4.57 m/s.

a.  Calculate the friction factor and the pressure drop in the smooth tube.

b.  Repeat, but for a commercial pipe having the same inside diameter with a roughness of ε
= 4.6 × 10−5 m.

A38:Ans. (a) NRe,gen  = 4855, f = 0.0073; (b) f = 0.0100
3.5-4 .
Ag it a t ion of a  Non-New t onia n Liq u id . A pseudoplastic liquid having the properties n =
0.53, K = 26.49 N · sn'/m2, and ρ = 975 kg/m3 is being agitated in a system such as in Fig. 3.5-4

where Dt = 0.304 m, Da  = 0.151 m, and N = 5 rev/s. Calculate μa ,  , and the kW power for


this system.

A39 :    = 4.028 Pa · s,   = 27.60,     3.1,   = 0.02966 kW

Ans. μa NP = P
3.5-5.
Velocit y  Pr ofile of a  Bing ha m Pla st ic Flu id . For the conditions of Example 3.5-3, do as
follows:

a.  Calculate the velocity for the plug-flow region at r = r 0.

b.  Calculate the velocity for values of r of 0.35 cm, 0.45 cm, and 0.50 cm and plot the
complete velocity profile versus radial position.

3.5-6
Pr essu r e Dr op  for  Bing ha m Pla st ic Flu id . A Bingham plastic fluid has a value of τ0 = 1.2

N/m2 and a viscosity μ = 0.4 Pa · s. The fluid is flowing at 5.70 × 10−5 m3/s in a pipe 2.5 m long
with an internal diameter of 3.0 cm. Calculate the pressure drop (p0 − pL) in N/m2 and r 0.
(Hint: This is a trial-and-error solution. As a first trial, assume τ0 = 0.)
A4 1: Ans.  (p  − p ) =  3400 N/m2
0 L
3.5-7.
Flow  Pr op er t ies of a  Non-New t onia n Flu id  fr om R ot a t iona l Viscomet er  Da t a .
Following are data obtained on a fluid using a Brookfield rotational viscometer:

RPM 0.5 1 2.5 5 10 20 50


Torque (dyn-cm) 86.2 168.9 402.5 754 1365 2379 4636

The diameter of the inner concentric rotating spindle is 25.15 mm, the outer cylinder diameter is
27.62 mm, and the effective length is 92.39 mm. Determine the flow properties of this non-
Newtonian fluid.
A4 2:Ans. n = 0.870
3.6 -1.
Eq u a t ion of C ont inu it y  in a  C y lind er . Fluid having a constant density ρ is flowing in the z
direction through a circular pipe with axial symmetry. The radial direction is designated by r.
a.  Using a cylindrical shell balance with dimensions dr and dz, derive the equation of
continuity for this system.

b.  Use the equation of continuity in cylindrical coordinates to derive the equation.

3.6 -2.
C ha ng e of C oor d ina t es for  C ont inu it y  Eq u a t ion. Using the general equation of
continuity given in rectangular coordinates, convert it to Eq. (3.6-27), which is the equation of
continuity in cylindrical coordinates. Use the relationships in Eq. (3.6-26) to do this.

3.7-1.
C omb ining  Eq u a t ions of C ont inu it y  a nd  M ot ion. Using the continuity equation and the
equations of motion for the x, y, and z components, derive Eq. (3.7-13).
3.8-1.
Av er a g e Velocit y  in a  C ir cu la r  Tu b e. Using Eq. (3.8-17) for the velocity in a circular tube as
a function of radius r,

Equation 3.8-17

derive Eq. (3.8-19) for the average velocity:

Equation 3.8-19

3.8-2.
La mina r  Flow  in a  C y lind r ica l Annu lu s. Derive all the equations given in Example 3.8-4
showing all the steps. Also, derive the equation for the average velocity νz av . Finally, integrate to
obtain the pressure drop from z = 0 for p = p0 to z = L for p = pL.
A4 7:  

Ans.
3.8-3.
Velocit y  Pr ofile in W et t ed -W a ll Tow er . In a vertical wetted-wall tower, the fluid flows
down the inside as a thin film δ m thick in laminar flow in the vertical z direction. Derive the
equation for the velocity profile νz, as a function of x, the distance from the liquid surface toward
the wall. The fluid is at a large distance from the entrance. Also, derive expressions for νz av  and
νz max. (Hint: At x = δ, which is at the wall, νz = 0. At x = 0, the surface of the flowing liquid, νz
= vz max.) Show all steps.
A4 8: Ans.  ν  = (ρgδ2/2μ)[1 − (x/δ)2], ν    = ρgδ2/3μ,  ν    =  2/2μ
z z av z max ρgδ
3.8-4 .
Velocit y  Pr ofile in Fa lling  Film a nd  Differ ent ia l M oment u m Ba la nce. A Newtonian
liquid is flowing as a falling film on an inclined flat surface. The surface makes an angle β with
the vertical. Assume that in this case the section being considered is sufficiently far from both
ends that there are no end effects on the velocity profile. The thickness of the film is δ. The
apparatus is similar to Fig. 2.9-3 but is not vertical. Do as follows:

a.  Derive the equation for the velocity profile of νz as a function of x in this film using the
differential momentum balance equation.

b.  What are the maximum velocity and the average velocity?

c.  What is the equation for the momentum flux distribution of τxz? [Hint: Can Eq. (3.7-19)
be used here?]

A4 9 : Ans.  (a) v  = (ρgδ2 cos β /2μ)[1 − (x/δ)2]; (c) τ  = ρgx cos β


z xz
3.8-5.
Velocit y  Pr ofiles for  Flow  Bet w een Pa r a llel Pla t es. In Example 3.8-2 a fluid is flowing
between vertical parallel plates with one plate moving. Do as follows:

a.  Determine the average velocity and the maximum velocity.

b.  Make a sketch of the velocity profile for three cases where the surface is moving upward,
moving downward, and stationary.

3.8-6 .
C onv er sion of S hea r  S t r esses in Ter ms of Flu id  M ot ion. Starting with the x component
of motion, Eq. (3.7-10), which is in terms of shear stresses, convert it to the equation of motion,
Eq. (3.7-36), in terms of velocity gradients, for a Newtonian fluid with constant ρ and μ. Note
that (∇·ν) = 0 in this case. Also, use of Eqs. (3.7-14)-(3.7-20) should be considered.
3.8-7.
Der iv a t ion of Eq u a t ion of C ont inu it y  in C y lind r ica l C oor d ina t es. By means of a mass
balance over a stationary element whose volume is r Δr Δθ Δz, derive the equation of continuity
in cylindrical coordinates.
3.8-8.
Flow  b et w een Tw o R ot a t ing  C oa xia l C y lind er s. The geometry of two coaxial cylinders is
the same as in Example 3.8-5. In this case, however, both cylinders are rotating, the inner
rotating with an annular velocity of ω 1 and the outer at ω 2. Determine the velocity and the
shear-stress distributions using the differential equation of momentum.
A53:  

Ans.
3.9 -1.
Pot ent ia l Fu nct ion. The potential function ϕ for a given flow situation is ϕ = C(x2 - y 2), where
C is a constant. Check to see if it satisfies Laplace's equation. Determine the velocity components
νx and νy .
A54 :Ans. vx = 2Cx, νy  = −2Cy (C = constant)
3.9 -2.
Det er mining  t he Velocit ies fr om t he Pot ent ia l Fu nct ion. The potential function for flow
is given as ϕ = Ax + By, where A and B are constants. Determine the velocities νx and νy .
3.9 -3.
S t r ea m Fu nct ion a nd  Velocit y  Vect or . Flow of a fluid in two dimensions is given by the
stream function ψ = Bxy, where B = 50s-1 and the units of x and y are in cm. Determine the value
of vx, vy , and the velocity vector at x = 1 cm and y = 1 cm.
A56 :Ans. ν = 70.7 cm/s
3.9 -4 .
S t r ea m Fu nct ion a nd  Pot ent ia l Fu nct ion. A liquid is flowing parallel to the x axis. The
flow is uniform and is represented by νx = U and vy  = 0.

a.  Find the stream function ψ for this flow field and plot the streamlines.

b.  Find the potential function and plot the potential lines.

A57:Ans. (a) ψ = Uy
3.9 -5.
Velocit y  C omp onent s a nd  S t r ea m Fu nct ion. A liquid is flowing in a uniform manner at an
angle of β with respect to the x axis. Its velocity components are νx = U cos β and νy  = U sin β.
Find the stream function and the potential function.
A58:Ans. ψ = Uy cos β − Ux sin β
3.9 -6 .
Flow  Field  w it h C oncent r ic S t r ea mlines. The flow of a fluid that has concentric
streamlines has a stream function represented by ψ = 1/(x2 + y 2). Find the components of
velocity νx and νy . Also, determine if the flow is rotational and, if so, determine the vorticity,
2ω z.
3.9 -7.
Pot ent ia l Fu nct ion a nd  Velocit y  Field . In Example 3.9-2 the velocity components were
given. Show if a velocity potential exists and, if so, also determine ϕ.
A6 0: Ans.  ϕ = ax3/3 − axy 2
3.9 -8.
Eu ler 's Eq u a t ion of M ot ion for  a n Id ea l Flu id . Using the Euler equations (3.9-2)–(3.9-4)
for ideal fluids with constant density and zero viscosity, obtain the following equation:

3.9 -9 .
Plot  of S t r ea mlines. For Ex. (3.9-3) plot the streamlines for ψ = 0 and ψ = 2 when x > 0.
3.9 -10.
S t r ea m Fu nct ion for  Tw o-Dimensiona l Flow . Find the stream function of the two-
dimensional flow with constant density where νx = U[(y/L)2 − (y/L)] and νy  = 0. The flow is
between two parallel plates spaced L distance apart. Also plot the velocity profile of νx versus y.

A6 3: . 

Ans
3.9 -11.
S t r ea m a nd  Pot ent ia l Fu nct ions a nd  Plot s of These Fu nct ions. Determine the stream
function ψ when the velocities are νx = 2x and νy  = -2y. Also determine the potential function ϕ.
Plot the stream function for ψ = 1 and ψ = 2. Also plot the equal potential lines for ϕ = 1 and ϕ =
4.
A6 4 : Ans.  ψ = 2xy, ϕ = x2 − y 2
3.9 -12. Velocit y  Field  fr om S t r ea m Fu nct ion. Given the stream function ψ = 3x2 + 2y 2, calculate
νx and νy  and draw the streamlines for ψ = 1 and ψ = 2.

A6 5:Ans. vx = 4y, vy  = −6x
3.9 -13.
S t r ea mline fr om Velocit ies. The velocity vx = x2 and vy  = -2xy. Determine the stream
function ψ.
A6 6 : Ans.  ψ = x2y
3.9 -14 .
S t r ea m Fu nct ion fr om Velocit y  Pot ent ia l. Find the stream function ψ from the velocity
potential ϕ = UL[(x/L)3 − (3xy 2)/L3], where U and L are constants. Also, find νx and νy .
A6 7:  

Ans.
3.10-1.
La mina r  Bou nd a r y  La y er  on Fla t  Pla t e. Water at 20°C is flowing past a flat plate at 0.914
m/s. The plate is 0.305 m wide.

a.  Calculate the Reynolds number 0.305 m from the leading edge to determine if the flow is
laminar.

b.  Calculate the boundary-layer thickness at x = 0.152 and x = 0.305 m from the leading
edge.

c.  Calculate the total drag on the 0.305-m-long plate.

A6 8: Ans.  (a) N  = 2.77 × 105; (b) δ =  0.0029 m at x =  0.305 m


Re,L
3.10-2.
Air  Flow  Pa st  a  Pla t e. Air at 294.3 K and 101.3 kPa is flowing past a flat plate at 6.1 m/s.
Calculate the thickness of the boundary layer at a distance of 0.3 m from the leading edge and
the total drag for a 0.3-m-wide plate.
3.10-3.
Bou nd a r y -La y er  Flow  Pa st  a  Pla t e. Water at 293 K is flowing past a flat plate at 0.5 m/s.
Do as follows:

a.  Calculate the boundary-layer thickness in m at a point 0.1 m from the leading edge.

b.  At the same point, calculate the point shear stress τ0. Also calculate the total drag
coefficient.

3.10-4 .
Tr a nsit ion Point  t o Tu r b u lent  Bou nd a r y  La y er . Air at 101.3 kPa and 293 K is flowing
past a smooth, flat plate at 100 ft/s. The turbulence in the air stream is such that the transition
from a laminar to a turbulent boundary layer occurs at NRe,L = 5 × 105.

a.  Calculate the distance from the leading edge where the transition occurs.

b.  Calculate the boundary-layer thickness δ at a distance of 0.5 ft and 3.0 ft from the leading
edge. Also calculate the drag coefficient for both distances L = 0.5 and 3.0 ft.
3.11-1.Dimensiona l Ana ly sis for  Flow  Pa st  a  Bod y . A fluid is flowing external to a solid body.
The force F exerted on the body is a function of the fluid velocity ν, fluid density ρ, fluid viscosity
μ, and a dimension of the body L. By dimensional analysis, obtain the dimensionless groups
formed from the variables given. (Note: Use the M, L, t system of units. The units of F are ML/t 2.
Select ν, ρ, and L as the core variables.)

A72: Ans.  π  =  (F/L2)/ρv2, π  = μ/Lvρ


1 2
3.11-2.
Dimensiona l Ana ly sis for  Bu b b le For ma t ion. Dimensional analysis is to be used to
correlate data on bubble size with the properties of the liquid when gas bubbles are formed by a
gas issuing from a small orifice below the liquid surface. Assume that the significant variables
are bubble diameter D, orifice diameter d, liquid density ρ, surface tension σ in N/m, liquid
viscosity μ, and g. Select d, ρ, and g as the core variables.
A73: Ans.  π  = D/d, π  = σ/ρd2g, π  = μ2/ρ2d3g
1 2 3
                             
                                                 
                                             
                                               
     

Chapter 4. Principles of Steady­State Heat Transfer
                             
                                                 
                                             
                                               
     

4.1. INTRODUCTION AND MECHANISMS OF HEAT TRANSFER

4 .1A. Intr od u ction to S te ad y-S tate  He at Tr ansfe r

The transfer of energy in the form of heat occurs in many chemical and other types of processes. Heat
transfer often occurs in combination with other separation processes, such as drying of lumber or foods,
alcohol distillation, burning of fuel, and evaporation. The heat transfer occurs because of a temperature-
difference driving force and heat flows from the high to the low-temperature region.

In Section 2.3 we derived an equation for a general property balance of momentum, thermal energy, or
mass at unsteady state by writing Eq. (2.3-7). Writing a similar equation but specifically for heat
transfer,

Equation 4.1-1

Assuming the rate of transfer of heat occurs only by conduction, we can rewrite Eq. (2.3-14), which is
Fourier's law, as

Equation 4.1-2

Making an unsteady-state heat balance for the x direction only on the element of volume or control
volume in Fig. 4.1-1 by using Eqs. (4.1-1) and (4.1-2), with the cross-sectional area being A m2,

Equation 4.1-3

Figure 4.1-1. Unsteady-state balance for heat tr ansfer in contr ol volume.


where   is rate of heat generated per unit volume. Assuming no heat generation and also assuming
steady-state heat transfer, where the rate of accumulation is zero, Eq. (4.1-3) becomes

Equation 4.1-4

This means the rate of heat input by conduction = the rate of heat output by conduction; or qx is a
constant with time for steady-state heat transfer.

In this chapter we are concerned with a control volume where the rate of accumulation of heat is zero and
we have steady-state heat transfer. The rate of heat transfer is then constant with time, and the
temperatures at various points in the system do not change with time. To solve problems in steady-state
heat transfer, various mechanistic expressions in the form of differential equations for the different
modes of heat transfer such as Fourier's law are integrated. Expressions for the temperature profile and
heat flux are then obtained in this chapter.

In Chapter 5 the conservation-of-energy equations (2.7-2) and (4.1-3) will be used again when the rate of
accumulation is not zero and unsteady-state heat transfer occurs. The mechanistic expression for
Fourier's law in the form of a partial differential equation will be used where the temperature at various
points and the rate of heat transfer change with time. In Section 5.6 a general differential equation of
energy change will be derived and integrated for various specific cases to determine the temperature
profile and heat flux.

4 .1B. Basic M e chanism s of He at Tr ansfe r

Heat transfer may occur by any one or more of the three basic mechanisms of heat transfer: conduction,
convection, and radiation.

1. C ond u ct ion

In conduction, heat can be conducted through solids, liquids, and gases. The heat is conducted by the
transfer of the energy of motion between adjacent molecules. In a gas the "hotter" molecules, which have
greater energy and motions, impart energy to the adjacent molecules at lower energy levels. This type of
transfer is present to some extent in all solids, gases, or liquids in which a temperature gradient exists. In
conduction, energy can also be transferred by "free" electrons, which is quite important in metallic solids.
Examples of heat transfer mainly by conduction are heat transfer through walls of exchangers or a
refrigerator, heat treatment of steel forgings, freezing of the ground during the winter, and so on.

2. C onv ect ion

The transfer of heat by convection implies the transfer of heat by bulk transport and mixing of
macroscopic elements of warmer portions with cooler portions of a gas or liquid. It also often refers to the
energy exchange between a solid surface and a fluid. A distinction must be made between forced-
convection heat transfer, where a fluid is forced to flow past a solid surface by a pump, fan, or other
mechanical means, and natural or free convection, where warmer or cooler fluid next to the solid surface
causes a circulation because of a density difference resulting from the temperature differences in the fluid.
Examples of heat transfer by convection are loss of heat from a car radiator where the air is being
circulated by a fan, cooking of foods in a vessel being stirred, cooling of a hot cup of coffee by blowing over
the surface, and so on.

3. R a d ia t ion

Radiation differs from heat transfer by conduction and convection in that no physical medium is needed
for its propagation. Radiation is the transfer of energy through space by means of electromagnetic waves
in much the same way as electromagnetic light waves transfer light. The same laws that govern the
transfer of light govern the radiant transfer of heat. Solids and liquids tend to absorb the radiation being
transferred through them, so that radiation is important primarily in transfer through space or gases.
The most important example of radiation is the transport of heat to the earth from the sun. Other
examples are cooking of food when passed below red-hot electric heaters, heating of fluids in coils of
tubing inside a combustion furnace, and so on.

4 .1C . Fou r ie r 's Law  of He at C ond u ction

As discussed in Section 2.3 for the general molecular transport equation, all three main types of rate-
transfer processes—momentum transfer, heat transfer, and mass transfer—are characterized by the same
general type of equation. The transfer of electric current can also be included in this category. This basic
equation is as follows:

Equation 2.3-1

This equation states what we know intuitively: that in order to transfer a property such as heat or mass,
we need a driving force to overcome a resistance.

The transfer of heat by conduction also follows this basic equation and is written as Fourier's law for heat
conduction in fluids or solids:

Equation 4.1-2
where qx is the heat-transfer rate in the x direction in watts (W), A is the cross-sectional area normal to

the direction of flow of heat in m2, T is temperature in K, x is distance in m, and k is the thermal
conductivity in W/m · K in the SI system. The quantity qx/A is called the heat flux in W/m2. The
quantity dT/dx is the temperature gradient in the x direction. The minus sign in Eq. (4.1-2) is required
because if the heat flow is positive in a given direction, the temperature decreases in this direction.

The units in Eq. (4.1-2) may also be expressed in the cgs system, with qx in cal/s, A in cm2, k in cal/s · °C

· cm, T in °C, and x in cm. In the English system, qx is in btu/h, A in ft 2, T in °F, x in ft, k in btu/h · °F ·

ft, and qx/A in btu/h · ft 2. From Appendix A.1, the conversion factors are, for thermal conductivity,

Equation 4.1-5

Equation 4.1-6

For heat flux and power,

Equation 4.1-7

Equation 4.1-8

Fourier's law, Eq. (4.1-2), can be integrated for the case of steady-state heat transfer through a flat wall of
constant cross-sectional area A, where the inside temperature is T1 at point 1 and T2 at point 2, a
distance of x2 - x1 m away. Rearranging Eq. (4.1-2),

Equation 4.1-9

Integrating, assuming that k is constant and does not vary with temperature and dropping the subscript
x on qx for convenience,

Equation 4.1-10
EXAMPLE 4.1-1. Heat Loss Through an Insulating Wall
Calculate the heat loss per m2 of surface area for an insulating wall composed of 25.4-mm-
thick fiber insulating board, where the inside temperature is 352.7 K and the outside
temperature is 297.1 K.

S olu t ion: From Appendix A.3, the thermal conductivity of fiber insulating board is 0.048
W/m · K. The thickness x2 - x1 = 0.0254 m. Substituting into Eq. (4.1-10),

4 .1D. The r m al C ond u ctiv ity

The defining equation for thermal conductivity is given as Eq. (4.1-2), and with this definition,
experimental measurements have been made to determine the thermal conductivity of different
materials. In Table 4.1-1 thermal conductivities are given for a few materials for the purpose of
comparison. More-detailed data are given in Appendix A.3 for inorganic and organic materials and
Appendix A.4 for food and biological materials. As seen in Table 4.1-1, gases have quite low values of
thermal conductivity, liquids intermediate values, and solid metals very high values.

Table 4.1-1. Thermal Conductivities of Some Materials at 101.325 kPa (1 Atm) Pressure (k in W/m
· K)

Temp. Temp.
Substance (K) k Ref. Substance (K) k Ref.

Gases       Solids      

  Air 273 0.0242 (K2)   Ice 273 2.25 (C1)


    373 0.0316     Fire claybrick 473 1.00 (P1)
  H2 273 0.167 (K2)   Paper — 0.130 (M1)
  n-Butane 273 0.0135 (P2)   Hard rubber 273 0.151 (M1)

Liquids         Cork board 303 0.043 (M1)


  Water 273 0.569 (P1)   Asbestos 311 0.168 (M1)

    366 0.680     Rock wool 266 0.029 (K1)

  Benzene 303 0.159 (P1)   Steel 291 45.3 (P1)


    333 0.151       373 45  

Biological         Copper 273 388 377 (P1)


materials and 373
foods
  Olive oil 293 0.168 0.164 (P1)   Aluminum 273 202 (P1)
373
  Lean beef 263 1.35 (C1)        

  Skim milk 275 0.538 (C1)        

  Applesauce 296 0.692 (C1)        


  Salmon 277 0.502 (C1)        
    248 1.30          

1. G a ses

In gases the mechanism of thermal conduction is relatively simple. The molecules are in continuous
random motion, colliding with one another and exchanging energy and momentum. If a molecule moves
from a high-temperature region to a region of lower temperature, it transports kinetic energy to this
region and gives up this energy through collisions with lower-energy molecules. Since smaller molecules
move faster, gases such as hydrogen should have higher thermal conductivities, as shown in Table 4.1-1.

Theories to predict thermal conductivities of gases are reasonably accurate and are given elsewhere (R1).
The thermal conductivity increases approximately as the square root of the absolute temperature and is
independent of pressure up to a few atmospheres. At very low pressures (vacuum), however, the thermal
conductivity approaches zero.

2. Liq u id s

The physical mechanism of conduction of energy in liquids is somewhat similar to that of gases, where
higher-energy molecules collide with lower-energy molecules. However, the molecules are packed so
closely together that molecular force fields exert a strong effect on the energy exchange. Since an adequate
molecular theory of liquids is not available, most correlations to predict the thermal conductivities are
empirical. Reid et al. (R1) discuss these in detail. The thermal conductivity of liquids varies moderately
with temperature and often can be expressed as a linear variation.

Equation 4.1-11

where a and b are empirical constants. Thermal conductivities of liquids are essentially independent of
pressure.

Water has a high thermal conductivity compared to organic-type liquids such as benzene. As shown in
Table 4.1-1, the thermal conductivities of most unfrozen foodstuffs, such as skim milk and applesauce,
which contain large amounts of water have thermal conductivities near that of pure water.

3. S olid s

The thermal conductivity of homogeneous solids varies quite widely, as may be seen for some typical
values in Table 4.1-1. The metallic solids of copper and aluminum have very high thermal conductivities,
while some insulating nonmetallic materials such as rock wool and corkboard have very low
conductivities.

Heat or energy is conducted through solids by two mechanisms. In the first, which applies primarily to
metallic solids, heat, like electricity, is conducted by free electrons which move through the metal lattice.
In the second mechanism, present in all solids, heat is conducted by the transmission of energy of
vibration between adjacent atoms.

Thermal conductivities of insulating materials such as rock wool approach that of air since the insulating
materials contain large amounts of air trapped in void spaces. Superinsulations to insulate cryogenic
materials such as liquid hydrogen are composed of multiple layers of highly reflective materials
separated by evacuated insulating spacers. Values of thermal conductivity are considerably lower than
for air alone.

Ice has a thermal conductivity much greater than water. Hence, the thermal conductivities of frozen
foods such as lean beef and salmon given in Table 4.1-1 are much higher than for unfrozen foods.

4 .1E. C onv e ctiv e  He at-Tr ansfe r  C oe fficie nt

It is well known that a hot piece of material will cool faster when air is blown or forced past the object.
When the fluid outside the solid surface is in forced or natural convective motion, we express the rate of
heat transfer from the solid to the fluid, or vice versa, by the following equation:

Equation 4.1-12

where q is the heat-transfer rate in W, A is the area in m2, Tw  is the temperature of the solid surface in K,
Tf is the average or bulk temperature of the fluid flowing past in K, and h is the convective heat-transfer

coefficient in W/m2 · K. In English units, h is in btu/h · ft 2 · °F.

The coefficient h is a function of the system geometry, fluid properties, flow velocity, and temperature
difference. In many cases, empirical correlations are available to predict this coefficient, since it often
cannot be predicted theoretically. Since we know that when a fluid flows past a surface there is a thin,
almost stationary layer or film of fluid adjacent to the wall which presents most of the resistance to heat
transfer, we often call the coefficient h a film coefficient.

In Table 4.1-2 some order-of-magnitude values of h for different convective mechanisms of free or natural
convection, forced convection, boiling, and condensation are given. Water gives the highest values of the
heat-transfer coefficients.

Table 4.1-2. Approximate Magnitude of Some Heat-Transfer Coefficients

  Range of Values of h

Mechanism btu/h · ft 2  · °F W/m 2  · K

Condensing steam 1000–5000 5700–28000


Condensing organics 200–500 1100–2800

Boiling liquids 300–5000 1700–28000


Moving water 50–3000 280–17000

Moving hydrocarbons 10–300 55–1700

Still air 0.5–4 2.8–23


Moving air 2–10 11.3–55

To convert the heat-transfer coefficient h from English to SI units,
                             
                                                 
                                             
                                               
     

4.2. CONDUCTION HEAT TRANSFER

4 .2A. C ond u ction Thr ou gh a Flat S lab  or  W all

In this section Fourier's equation (4.1-2) will be used to obtain equations for one-dimensional steady-
state conduction of heat through some simple geometries. For a flat slab or wall where the cross-sectional
area A and k in Eq. (4.1-2) are constant, we obtained Eq. (4.1-10), which we rewrite as

Equation 4.2-1

This is shown in Fig. 4.2-1, where Δx = x2 - x1. Equation (4.2-1) indicates that if T is substituted for T2
and x for X2, the temperature varies linearly with distance, as shown in Fig. 4.2-1b .

Figure 4.2-1. Heat conduction in a flat wall: (a) geometr y of wall, (b) temperature plot.

If the thermal conductivity is not constant but varies linearly with temperature, then substituting Eq.
(4.1-11) into Eq. (4.1-2) and integrating,

Equation 4.2-2
where

Equation 4.2-3

This means that the mean value of k (i.e., km) to use in Eq. (4.2-2) is the value of k evaluated at the linear
average of T 1 and T 2.

As stated in the introduction to transport processes in Eq. (2.3-1), the rate of a transfer process equals the
driving force over the resistance. Equation (4.2-1) can be rewritten in that form:

Equation 4.2-4

where R = Δx/kA and is the resistance in K/W or h · °F/btu.

4 .2B. C ond u ction Thr ou gh a Hollow  C ylind e r

In many instances in the process industries, heat is being transferred through the walls of a thick-walled
cylinder, such as a pipe that may or may not be insulated. Consider the hollow cylinder in Fig. 4.2-2 with
an inside radius of r 1,  where the temperature is T1, an outside radius of r 2 having a temperature of T2,
and a length of L m. Heat is flowing radially from the inside surface to the outside. Rewriting Fourier's
law, Eq. (4.1-2), with distance dr instead of dx,

Equation 4.2-5

Figure 4.2-2. Heat conduction in a cylinder.
The cross-sectional area normal to the heat flow is

Equation 4.2-6

Substituting Eq. (4.2-6) into (4.2-5), rearranging, and integrating,

Equation 4.2-7

Equation 4.2-8

Multiplying numerator and denominator by (r 2 - r 1),

Equation 4.2-9

where

Equation 4.2-10

Equation 4.2-11

The log mean area is Alm. In engineering practice, if A2/A1 < 1.5/1, the linear mean area of (A1 + A2)/2 is
within 1.5% of the log mean area. From Eq. (4.2-8), if r is substituted for r 2 and T for T2, the temperature
is seen to be a linear function of In r instead of r as in the case of a flat wall. If the thermal conductivity
varies with temperature as in Eq. (4.1-10), it can be shown that the mean value to use in a cylinder is still
km of Eq. (4.2-3).

EXAMPLE 4.2-1. Length of Tubing for Cooling Coil
A thick-walled cylindrical tubing of hard rubber having an inside radius of 5 mm and an
outside radius of 20 mm is being used as a temporary cooling coil in a bath. Ice water is
flowing rapidly inside, and the inside wall temperature is 274.9 K. The outside surface
temperature is 297.1 K. A total of 14.65 W must be removed from the bath by the cooling coil.
How many m of tubing are needed?

S olu t ion: From Appendix A.3, the thermal conductivity at 0°C (273 K) is k = 0.151 W/m · K.
Since data at other temperatures are not available, this value will be used for the range of 274.9
to 297.1 K.

The calculation will be done first for a length of 1.0 m of tubing. Solving for the areas A1, A2,
and Alm in Eq. (4.2-10),

Substituting into Eq. (4.2-9) and solving,

The negative sign indicates that the heat flow is from r 2 on the outside to r 1 on the inside.


Since 15.2 W is removed for a 1-m length, the needed length is

Note that the thermal conductivity of rubber is quite small. Generally, metal cooling coils are used, since
the thermal conductivity of metals is quite high. The liquid film resistances in this case are quite small
and are neglected.

4 .2C . C ond u ction Thr ou gh a Hollow  S p he r e


Heat conduction through a hollow sphere is another case of one-dimensional conduction. Using Fourier's
law for constant thermal conductivity with distance d r , where r  is the radius of the sphere,

Equation 4.2-5

The cross-sectional area normal to the heat flow is

Equation 4.2-12

Substituting Eq. (4.2-12) into (4.2-5), rearranging, and integrating,

Equation 4.2-13

Equation 4.2-14

It can easily be shown that the temperature varies hyperbolically with the radius. (See Problem 4.2-5.)
                             
                                                 
                                             
                                               
     

4.3. CONDUCTION THROUGH SOLIDS IN SERIES

4 .3A. Plane  W alls in S e r ie s

In the case where there is a multilayer wall of more than one material present, as shown in Fig. 4.3-1, we
proceed as follows. The temperature profiles in the three materials A, B, and C  a r e shown. Since the heat
flow q  must be the same in each layer, we can write Fourier's equation for each layer as

Equation 4.3-1

Figure 4.3-1. Heat flow through a multilayer wall.

Solving each equation for ΔT,

Equation 4.3-2

Adding the equations for T1 − T2, T2 − T3, and T3 − T4, the internal temperatures T2 and T3 drop out and
the final rearranged equation is

Equation 4.3-3
where the resistance RA = ΔxA/kAA, and so on.

Hence, the final equation is in terms of the overall temperature drop, T1 − T4, and the total resistance, RA
+ RB + Rc.

EXAMPLE 4.3-1. Heat Flow Through an Insulated Wall of a
Cold Room
A cold-storage room is constructed of an inner layer of 12.7 mm of pine, a middle layer of 101.6
mm of cork board, and an outer layer of 76.2 mm of concrete. The wall surface temperature is
255.4 K inside the cold room and 297.1 K at the outside surface of the concrete. Use
conductivities from Appendix A.3 for pine, 0.151; for cork board, 0.0433; and for concrete,
0.762 W/m · K. Calculate the heat loss in W for 1 m2 and the temperature at the interface
between the wood and cork board.

S olu t ion: Calling T1 = 255.4, T4 = 297.1 K, pine as material A, cork as B, and concrete as C, a
tabulation of the properties and dimensions is as follows:

The resistances for each material are, from Eq. (4.3-3), for an area of 1 m2,

Substituting into Eq. (4.3-3),

Since the answer is negative, heat flows in from the outside.
To calculate the temperature T2 at the interface between the pine wood and cork,

Substituting the known values and solving,

An alternative procedure for calculating T2 is to use the fact that the temperature drop is
proportional to the resistance:

Equation 4.3-4

Substituting,

Hence, T2 = 256.79 K, as calculated before.

4 .3B. M u ltilaye r  C ylind e r s

In the process industries, heat transfer often occurs through multilayers of cylinders, as for example
when heat is being transferred through the walls of an insulated pipe. Figure 4.3-2 shows a pipe with two
layers of insulation around it, that is, a total of three concentric hollow cylinders. The temperature drop
is T1 − T2 across material A, T2 − T3 across B, and T3 − T4 across C.

Figure 4.3-2. Radial heat flow through multiple cylinders in series.
The heat-transfer rate q will, of course, be the same for each layer, since we are at steady state. Writing an
equation similar to Eq. (4.2-9) for each concentric cylinder,

Equation 4.3-5

where

Equation 4.3-6

Using the same method of combining the equations to eliminate T2 and T3 as was done for the flat walls
in series, the final equations are

Equation 4.3-7

Equation 4.3-8

Hence, the overall resistance is again the sum of the individual resistances in series.
EXAMPLE 4.3-2. Heat Loss from an Insulated Pipe
A thick-walled tube of stainless steel (A) having a k = 21.63 W/m · K with dimensions of
0.0254 m ID and 0.0508 m OD is covered with a 0.0254-m-thick layer of an insulation (B), k
= 0.2423 W/m · K. The inside-wall temperature of the pipe is 811 K and the outside surface of
the insulation is at 310.8 K. For a 0.305-m length of pipe, calculate the heat loss and also the
temperature at the interface between the metal and the insulation.

S olu t ion: Calling T1 = 811 K, T2 the interface, and T3 = 310.8 K, the dimensions are

The areas are as follows for L = 0.305 m:

From Eq. (4.3-6), the log mean areas for the stainless steel (A) and insulation (B) are

From Eq. (4.3-7) the resistances are

Hence, the heat-transfer rate is

To calculate the temperature T2,
Solving, 811 − T2 = 5.5 K and T2 = 805.5 K. Only a small temperature drop occurs across the
metal wall because of its high thermal conductivity.

4 .3C . C ond u ction Thr ou gh M ate r ials in Par alle l

Suppose that two plane solids A and B are placed side by side in parallel, and the direction of heat flow is
perpendicular to the plane of the exposed surface of each solid. Then the total heat flow is the sum of the
heat flow through solid A plus that through B. Writing Fourier's equation for each solid and summing,

Equation 4.3-9

where qT is total heat flow, T1 and T2 are the front and rear surface temperatures for solid A, and T3 and
T4 are those for solid B.

If we assume that T1 = T3 (front temperatures the same for A and B) and T2 = T4 (equal rear
temperatures),

Equation 4.3-10

An example would be an insulated wall (A) of a brick oven where steel reinforcing members (B) are in
parallel and penetrate the wall. Even though the area AB of the steel would be small compared to the
insulated brick area AA, the higher conductivity of the metal (which could be several hundred times
larger than that of the brick) could allow a large portion of the heat lost to be conducted by the steel.

Another example is a method of increasing heat conduction to accelerate the freeze-drying of meat.
Spikes of metal in the frozen meat conduct heat more rapidly into the insides of the meat.

It should be mentioned that in some cases some two-dimensional heat flow can occur if the thermal
conductivities of the materials in parallel differ markedly. Then the results using Eq. (4.3-10) would be
affected somewhat.

4 .3D. C om b ine d  C onv e ction and  C ond u ction and  Ov e r all C oe fficie nts

In many practical situations the surface temperatures (or boundary conditions at the surface) are not
known, but there is a fluid on both sides of the solid surfaces. Consider the plane wall in Fig. 4.3-3a, with
a hot fluid at temperature T1 on the inside surface and a cold fluid at T4 on the outside surface. The
convective coefficient on the outside is ho W/m2 · K and hi on the inside. (Methods for predicting the
convective h will be given later, in Section 4.4 of this chapter.)

Figure 4.3-3. Heat flow with convective boundaries: (a) plane wall, (b) cylindrical wall.

The heat-transfer rate using Eqs. (4.1-12) and (4.3-1) is given as

Equation 4.3-11

Expressing 1/hiA, ΔxA/kAA, and 1/hoA as resistances and combining the equations as before,

Equation 4.3-12

The overall heat transfer by combined conduction and convection is often expressed in terms of an overall
heat-transfer coefficient U defined by

Equation 4.3-13

where ΔToverall = T1 − T4 and U is

Equation 4.3-14
A more important application is heat transfer from a fluid outside a cylinder, through a metal wall, to a
fluid inside the tube, as often occurs in heat exchangers. In Fig. 4.3-3b, such a case is shown.

Using the same procedure as before, the overall heat-transfer rate through the cylinder is

Equation 4.3-15

where Ai represents 2πLr i, the inside area of the metal tube; AA lm the log mean area of the metal tube;
and A0 the outside area.

The overall heat-transfer coefficient U for the cylinder may be based on the inside area Ai or the outside
area A0 of the tube. Hence,

Equation 4.3-16

Equation 4.3-17

Equation 4.3-18

EXAMPLES 4.3-3. Heat Loss by Convection and
Conduction and Overall U

Saturated steam at 267°F is flowing inside a   -in. steel pipe having an ID of 0.824 in. and an
OD of 1.050 in. The pipe is insulated with 1.5 in. of insulation on the outside. The convective
coefficient for the inside steam surface of the pipe is estimated as hi = 1000 btu/h · ft 2 · °F, and

the convective coefficient on the outside of the lagging is estimated as ho = 2 btu/h · ft 2 · °F.
The mean thermal conductivity of the metal is 45 W/m · K or 26 btu/h · ft · °F and 0.064 W/m
· K or 0.037 btu/h · ft · °F for the insulation.

a.  Calculate the heat loss for 1 ft of pipe using resistances if the surrounding air is at 80°F

b.  Repeat, using the overall Ui based on the inside area Ai.

S olu t ion: Calling r i the inside radius of the steel pipe, r 1 the outside radius of the pipe, and r 0


the outside radius of the lagging, then

For 1 ft of pipe, the areas are as follows:

From Eq. (4.3-6), the log mean areas for the steel (A) pipe and lagging (B) are

From Eq. (4.3-15) the various resistances are
Using an equation similar to Eq. (4.3-15),

Equation 4.3-19

For part (b), the equation relating Ui to q is Eq. (4.3-16), which can be equated to Eq. (4.3-19):

Equation 4.3-20

Solving for Ui,

Equation 4.3-21

Substituting known values,

Then to calculate q,

4 .3E. C ond u ction w ith Inte r nal He at G e ne r ation

In certain systems heat is generated inside the conducting medium; that is, a uniformly distributed heat
source is present. Examples of this are electric-resistance heaters and nuclear fuel rods. Also, if a
chemical reaction is occurring uniformly in a medium, a heat of reaction is given off. In the agricultural
and sanitation fields, compost heaps and trash heaps in which biological activity is occurring will have
heat given off.

Other important examples are in food processing, where the heat of respiration of fresh fruits and
vegetables is present. These heats of generation can be as high as 0.3 to 0.6 W/kg or 0.5 to 1 btu/h · lbm.
1. Hea t  g ener a t ion in p la ne w a ll

In Fig. 4.3-4 a plane wall is shown with internal heat generation. Heat is conducted only in the x
direction. The other walls are assumed to be insulated. The temperature Tw  in K at x = L and x = −L is

held constant. The volumetric rate of heat generation is   W/m3 and the thermal conductivity of the
medium is k W/m · K.

Figure 4.3-4. Plane wall with internal heat generation at steady state.

To derive the equation for this case of heat generation at steady state, we start with Eq. (4.1-3) but drop
the accumulation term:

Equation 4.3-22

where A is the cross-sectional area of the plate. Rearranging, dividing by Δx, and letting Δx approach
zero,

Equation 4.3-23

Substituting Eq. (4.1-2) for qx,

Equation 4.3-24
Integration gives the following for   constant:

Equation 4.3-25

where C 1 and C 2 are integration constants. The boundary conditions are at x = L or −L, T = Tw , and at x


= 0, T = T0 (center temperature). Then, the temperature profile is

Equation 4.3-26

The center temperature is

Equation 4.3-27

The total heat lost from the two faces at steady state is equal to the total heat generated,  , in W:

Equation 4.3-28

where A is the cross-sectional area (surface area at T w ) of the plate.

2. Hea t  g ener a t ion in cy lind er

In a similar manner an equation can be derived for a cylinder of radius R with uniformly distributed heat
sources and constant thermal conductivity. The heat is assumed to flow only radially, that is, the ends
are neglected or insulated. The final equation for the temperature profile is

Equation 4.3-29
where r  is distance from the center. The center temperature T 0  is

Equation 4.3-30

EXAMPLE 4.3-4. Heat Generation in a Cylinder
An electric current of 200 A is passed through a stainless-steel wire having a radius R of
0.001268 m. The wire is L = 0.91 m long and has a resistance R of 0.126 ohms. The outer
surface temperature T w  is held at 422.1 K. The average thermal conductivity is k = 22.5 W/m ·
K. Calculate the center temperature.

S olu t ion: First the value of   must be calculated. Since power = I 2 R , w he r e  I is current in


amps and R is resistance in ohms,

Equation 4.3-31

Substituting known values and solving,

Substituting into Eq. (4.3-30) and solving, T 0  = 441.7 K.

4 .3F. C r itical Thickne ss of Insu lation for  a C ylind e r

In Fig. 4.3-5 a layer of insulation is installed around the outside of a cylinder whose radius r 1 is fixed and
with a length L. The cylinder has a high thermal conductivity and the inner temperature T1 at point r 1
outside the cylinder is fixed. An example is the case where the cylinder is a metal pipe with saturated
steam inside. The outer surface of the insulation at T 2 is exposed to an environment at T 0 where
convective heat transfer occurs. It is not obvious if adding more insulation with a thermal conductivity of
k  w ill decrease the heat-transfer rate.

Figure 4.3-5. Critical radius for insulation of cylinder or pipe.
At steady state the heat-transfer rate q  through the cylinder and the insulation equals the rate of
convection from the surface:

Equation 4.3-32

As insulation is added, the outside area, which is A = 2πr 2 L, increases, but T2 decreases. However, it is
not apparent whether q increases or decreases. To determine this, an equation similar to Eq. (4.3-15)
with the resistance of the insulation represented by Eq. (4.2-11) is written using the two resistances:

Equation 4.3-33

To determine the effect of the thickness of insulation on q, we take the derivative of q with respect to r 2,
equate this result to zero, and obtain the following for maximum heat flow:

Equation 4.3-34

Solving,

Equation 4.3-35
where (r2)cr  is the value of the critical radius when the heat-transfer rate is a maximum. Hence, if the
outer radius r2 is less than the critical value, adding more insulation will actually increase the heat-
transfer rate q. Also, if the outer radius is greater than the critical, adding more insulation will decrease
the heat-transfer rate. Using values of k and ho typically encountered, the critical radius is only a few
mm. As a result, adding insulation on small electrical wires could increase the heat loss. Adding
insulation to large pipes decreases the heat-transfer rate.

EXAMPLE 4.3-5. Insulating an Electrical Wire and Critical
Radius
An electric wire having a diameter of 1.5 mm and covered with a plastic insulation (thickness
= 2.5 mm) is exposed to air at 300 K and h0 = 20 W/m2 · K. The insulation has a k of 0.4 W/m 
· K. It is assumed that the wire surface temperature is constant at 400 K and is not affected by
the covering.

a.  Calculate the value of the critical radius.

b.  Calculate the heat loss per m of wire length with no insulation.

c.  Repeat (b) for insulation being present.

S olu t ion: For part (a), using Eq. (4.3-35),

For part (b), L = 1.0 m, r 2 = 1.5/(2 × 1000) = 0.75 × 10–3 m, A = 2πr 2L. Substituting into Eq.


(4.3-32),

For part (c) with insulation, r 1 = 1.5/(2 × 1000) = 0.75 × 10–3 m, r 2 = (2.5 + 1.5/2)/1000 =

3.25 × 10–3 m. Substituting into Eq. (4.3-33),

Hence, adding insulation greatly increases the heat loss.

4 .3G . C ontact R e sistance  at an Inte r face

In the equations derived in this section for conduction through solids in series (see Fig. 4.3-1), it has been
assumed that the adjacent touching surfaces are at the same temperature, that is, that completely
perfect contact is made between the surfaces. For many engineering designs in industry, this assumption
is reasonably accurate. However, in cases such as in nuclear power plants, where very high heat fluxes are
present, a significant drop in temperature may be present at the interface. This interface resistance,
called contact resistance, occurs when the two solids do not fit tightly together and a thin layer of
stagnant fluid is trapped between the two surfaces. At some points the solids touch at peaks in the
surfaces and at other points the fluid occupies the open space.

This interface resistance is a complex function of the roughness of the two surfaces, the pressure applied
to hold the surfaces in contact, the interface temperature, and the interface fluid. Heat transfer takes
place by conduction, radiation, and convection across the trapped fluid and also by conduction through
the points of contact of the solids. No completely reliable empirical correlations or theories are available
to predict contact resistances for all types of materials. See references (C7, R2) for detailed discussions.

The equation for the contact resistance is often given as follows:

Equation 4.3-36

where hc is the contact-resistance coefficient in W/m2 · K, ΔT the temperature drop across the contact
resistance in K, and Rc the contact resistance. The contact resistance Rc can be added to the other
resistances in Eq. (4.3-3) to include this effect for solids in series. For contact between two ground-metal
surfaces, hc values on the order of magnitude of about 0.2 × 104 to 1 × 104 W/m2 · K have been obtained.

An approximation of the maximum contact resistance can be obtained if the maximum gap Δx between
the surfaces can be estimated. Then, assuming that the heat transfer across the gap is by conduction only
through the stagnant fluid, hc is estimated as

Equation 4.3-37

If any actual convection, radiation, or point-to-point contact is present, it will reduce this assumed
resistance.
                             
                                                 
                                             
                                               
     

4.4. STEADY­STATE CONDUCTION AND SHAPE FACTORS

4 .4 A. Intr od u ction and  G r ap hical M e thod  for  Tw o-Dim e nsional C ond u ction

In previous sections of this chapter we discussed steady-state heat conduction in one direction. In many
cases, however, steady-state heat conduction is occurring in two directions, that is, two-dimensional
conduction is occurring. The two-dimensional solutions are more involved and in most cases analytical
solutions are not available. One important approximate method for solving such problems is to use a
numerical method discussed in detail in Section 4.15. Another important approximate method is the
graphical method, which is a simple method that can provide reasonably accurate answers for the heat-
transfer rate. This method is particularly applicable to systems having isothermal boundaries.

In the graphical method we first note that for one-dimensional heat conduction through a flat slab (see
Fig. 4.2-1) the direction of the heat flux or flux lines is always perpendicular to the isotherms. The
graphical method for two-dimensional conduction is also based on the requirement that the heat-flux
lines and isotherm lines intersect each other at right angles while forming a network of curvilinear
squares. This means, as shown in Fig. 4.4-1, that we can sketch the isotherms and also the flux lines
until they intersect at right angles (are perpendicular to each other). With care and experience we can
obtain reasonably accurate results. General steps to use in this graphical method are as follows:

1. Draw a model to scale of the two-dimensional solid. Label the isothermal boundaries. In Fig. 4.4-1,
T1 and T2 are isothermal boundaries.

2. Select a number N that is the number of equal temperature subdivisions between the isothermal
boundaries. In Fig. 4.4-1, N = 4 subdivisions between T1 and T2. Sketch in the isotherm lines and the
heat-flow or -flux lines so that they are perpendicular to each other at the intersections. Note that
isotherms are perpendicular to adiabatic (insulated) boundaries and also lines of symmetry.

3. Keep adjusting the isotherm and flux lines until for each curvilinear square the condition Δx = Δy is
satisfied.

Figure 4.4-1. Graphical curvilinear-square method for two-dimensional heat conduction in a rectangular flue.
In order to calculate the heat flux using the results of the graphical plot, we first assume unit depth of the
material. The heat flow q' through the curvilinear section shown in Fig. 4.4-1 is given by Fourier's law:

Equation 4.4-1

This heat flow q' will be the same through each curvilinear square within this heat-flow lane. Since Δx =
Δy, each temperature subdivision ΔT is equal. This temperature subdivision can be expressed in terms of
the overall temperature difference T1 − T2 and N, the number of equal subdivisions:

Equation 4.4-2

Also, the heat flow q' through each lane is the same, since Δx = Δy in the construction and in Eq. (4.4-1).
Hence, the total heat transfer q through all of the lanes is

Equation 4.4-3

where M is the total number of heat-flow lanes as determined by the graphical procedure. Substituting
Eq. (4.4-2) into (4.4-3),

Equation 4.4-4
EXAMPLE 4.4-1. Two-Dimensional Conduction by
Graphical Procedure
Determine the total heat transfer through the walls of the flue shown in Fig. 4.4-1 if T 1
= 6 00 K , T 2  = 400 K, k = 0.90 W/m · K, and L (length of flue) = 5 m.

S olu t ion: In Fig. 4.4-1, N = 4 temperature subdivisions and M = 9.25. The total heat-transfer
rate through the four identical sections with a depth or length L of 5 m is obtained by using Eq.
(4.4-4):

4 .4 B. S hap e  Factor s in C ond u ction

In Eq. (4.4-4) the factor M/N is called the conduction shape factor S , where

Equation 4.4-5

Equation 4.4-6

This shape factor S has units of m and is used in two-dimensional heat conduction where only two
temperatures are involved. The shape factors for a number of geometries have been obtained and some
are given in Table 4.4-1.

Table 4.4-1. Conduction Shape Factors for q = kS(T1  − T2 )[*]

Cylinder of length L
in a square
Horizontal buried
cylinder of length
L

Two parallel cylinders
of length
L

Sphere buried

[*]
 The thermal conductivity of the medium is k.

For a three-dimensional geometry such as a furnace, separate shape factors are used to obtain the heat
flow through the edge and corner sections. When each of the interior dimensions is greater than one-fifth
of the wall thickness, the shape factors are as follows for a uniform wall thickness T w :

Equation 4.4-7

where A is the inside area of wall and L the length of inside edge. For a completely enclosed geometry,
there are six wall sections, 12 edges, and eight corners. Note that for a single flat wall, q = kSwall(T1 − T2)
= k(A/Tw )(T1 − T2), which is the same as Eq. (4.2-1) for conduction through a single flat slab.

For a long, hollow cylinder of length L such as that in Fig. 4.2-2,

Equation 4.4-8

For a hollow sphere, from Eq. (4.2-14),

Equation 4.4-9
                             
                                                 
                                             
                                               
     

4.5. FORCED CONVECTION HEAT TRANSFER INSIDE PIPES

4 .5A. Intr od u ction and  Dim e nsionle ss Nu m b e r s

In most situations involving a liquid or a gas in heat transfer, convective heat transfer usually occurs as
well as conduction. In most industrial processes where heat transfer is occurring, heat is being
transferred from one fluid through a solid wall to a second fluid. In Fig. 4.5-1 heat is being transferred
from the hot flowing fluid to the cold flowing fluid. The temperature profile is shown.

Figure 4.5-1. Temperature profile for heat tr ansfer by convection fr om one fluid to another

The velocity gradient, when the fluid is in turbulent flow, is very steep next to the wall in the thin viscous
sublayer where turbulence is absent. Here the heat transfer is mainly by conduction, with a large
temperature difference of T2 − T3 in the warm fluid. As we move farther away from the wall, we approach
the turbulent region, where rapidly moving eddies tend to equalize the temperature. Hence, the
temperature gradient is less and the difference T1 − T2 is small. The average temperature of fluid A is
slightly less than the peak value T1. A similar explanation can be given for the temperature profile in the
cold fluid.

The convective coefficient for heat transfer through a fluid is given by

Equation 4.5-1

where h is the convective coefficient in W/m2 · K, A is the area in m2, T is the bulk or average temperature
of the fluid in K, Tw  is the temperature of the wall in contact with the fluid in K, and q is the heat-transfer
rate in W. In English units, q is in btu/h, h in btu/h · ft 2 · °F, A in ft 2, and T and Tw  in °F.

The type of fluid flow, whether laminar or turbulent, of the individual fluid has a great effect on the heat-
transfer coefficient h, which is often called a film coefficient, since most of the resistance to heat transfer
is in a thin film close to the wall. The more turbulent the flow, the greater the heat-transfer coefficient.

There are two main classifications of convective heat transfer. The first is free or natural convection,
where the motion of the fluid results from the density changes in heat transfer. The buoyant effect
produces a natural circulation of the fluid, so it moves past the solid surface. In the second type, forced
convection, the fluid is forced to flow by pressure differences, a pump, a fan, and so on.

Most of the correlations for predicting film coefficients h are semiempirical in nature and are affected by
the physical properties of the fluid, the type and velocity of flow, the temperature difference, and the
geometry of the specific physical system. Some approximate values for convective coefficients were
presented in Table 4.1-2. In the following correlations, either SI or English units can be used, since the
equations are dimensionless.

To correlate these data for heat-transfer coefficients, dimensionless numbers such as the Reynolds and
Prandtl numbers are used. The Prandtl number is the ratio of the shear component of diffusivity for
momentum μ/ρ to the diffusivity for heat k/ρcp and physically relates the relative thicknesses of the
hydrodynamic layer and thermal boundary layer:

Equation 4.5-2

Values of the NPr  for gases are given in Appendix A.3 and range from about 0.5 to 1.0. Values for liquids

range from about 2 to well over 104. The dimensionless Nusselt number, NNu, is used to relate data for
the heat-transfer coefficient h to the thermal conductivity k of the fluid and a characteristic dimension D:

Equation 4.5-3

For example, for flow inside a pipe, D is the diameter.

4 .5B. He at-Tr ansfe r  C oe fficie nt for  Lam inar  Flow  Insid e  a Pip e

Certainly, the most important convective heat-transfer process industrially is that of cooling or heating a
fluid flowing inside a closed circular conduit or pipe. Different types of correlations for the convective
coefficient are needed for laminar flow (NRe below 2100), for fully turbulent flow (NRe above 6000), and
for the transition region (NRe between 2100 and 6000).

For laminar flow of fluids inside horizontal tubes or pipes, the following equation of Sieder and Tate (S1)
can be used for NRe < 2100:

Equation 4.5-4
where D = pipe diameter in m, L = pipe length before mixing occurs in the pipe in m, μb = fluid viscosity
at bulk average temperature in Pa · s, μw  = viscosity at the wall temperature, cp = heat capacity in J/kg ·

K, k = thermal conductivity in W/m · K, ha  = average heat-transfer coefficient in W/m2 · K, and NNu =
dimensionless Nusselt number. All the physical properties are evaluated at the bulk fluid temperature
except μw . The Reynolds number is

Equation 4.5-5

and the Prandtl number,

Equation 4.5-6

This equation holds for (NReNPr D/L) > 100. If used down to (NReNPr D/L) > 10, it still holds to ±20%


(B1). For (NReNPr D/L) < 100, another expression is available (P1).

In laminar flow the average coefficient ha  depends strongly on heated length. The average (arithmetic
mean) temperature drop ΔTa  is used in the equation to calculate the heat-transfer rate q:

Equation 4.5-7

where Tw  is the wall temperature in K, Tbi the inlet bulk fluid temperature, and Tbo the outlet bulk fluid
temperature.

For large pipe diameters and large temperature differences ΔT between pipe wall and bulk fluid, natural
convection effects can increase h (P1). Equations are also available for laminar flow in vertical tubes.

4 .5C . He at-Tr ansfe r  C oe fficie nt for  Tu r b u le nt Flow  Insid e  a Pip e

When the Reynolds number is above 6000, the flow is fully turbulent. Since the rate of heat transfer is
greater in the turbulent region, many industrial heat-transfer processes are in the turbulent region.

The following equation has been found to hold for tubes but is also used for pipes. It holds for a NRe >
6000, a NPr  between 0.7 and 16 000, and L/D > 60.
Equation 4.5-8

where hL is the heat-transfer coefficient based on the log mean driving force ΔTlm (see Section 4.5H). The
fluid properties except for μw  are evaluated at the mean bulk temperature. If the bulk fluid temperature
varies from the inlet to the outlet of the pipe, the mean of the inlet and outlet temperatures is used. For
an LID < 60, where the entry is an abrupt contraction, an approximate correction is provided by
multiplying the right-hand side of Eq. (4.5-8) by a correction factor given in Section 4.5F.

The use of Eq. (4.5-8) may be trial and error, since the value of hL must be known in order to evaluate Tw ,
and hence μw , at the wall temperature. Also, if the mean bulk temperature increases or decreases in the
tube length L because of heat transfer, the bulk temperature at length L must be estimated in order to
have a mean bulk temperature of the entrance and exit to use.

The heat-transfer coefficient for turbulent flow is somewhat greater for a pipe than for a smooth tube.
This effect is much less than in fluid friction, and it is usually neglected in calculations. Also, for liquid
metals that have Prandtl numbers << 1, other correlations must be used to predict the heat-transfer
coefficient. (See Section 4.5G.) For shapes of tubes other than circular, the equivalent diameter can be
used, as discussed in Section 4.5E.

For air at 1 atm total pressure, the following simplified equation holds for turbulent flow in pipes:

Equation 4.5-9

where D is in m, ν in m/s, and hL in W/m2 · K for SI units; and D' is in in., νs in ft/s, and hL in btu/h · ft 2 ·
°F for English units.

Water is often used in heat-transfer equipment. A simplified equation to use for a temperature range of T
= 4−105°C (40−220°F) is

Equation 4.5-10
For organic liquids, a very simplified equation to use for approximations is as follows (P3):

Equation 4.5-11

For flow inside helical coils and NRe above 104, the predicted film coefficient for straight pipes should be
increased by the factor (1 + 3.5D/Dcoil).

EXAMPLE 4.5-1. Heating of Air in Turbulent Flow
Air at 206.8 kPa and an average of 477.6 K is being heated as it flows through a tube of 25.4
mm inside diameter at a velocity of 7.62 m/s. The heating medium is 488.7 K steam
condensing on the outside of the tube. Since the heat-transfer coefficient of condensing steam
is several thousand W/m2 · K and the resistance of the metal wall is very small, it will be
assumed that the surface wall temperature of the metal in contact with the air is 488.7 K.
Calculate the heat-transfer coefficient for an L/D > 60 and also the heat-transfer flux q/A.

S olu t ion: From Appendix A.3, for physical properties of air at 477.6 K (204.4°C), μb = 2.60 ×

10-5 Pa · s, k = 0.03894 W/m, NPr  = 0.686. At 488.7 K (215.5°C), μw  = 2.64 × KT5 Pa · s.

The Reynolds number calculated at the bulk fluid temperature of 477.6 K is

Hence, the flow is turbulent and Eq. (4.5-8) will be used. Substituting into Eq. (4.5-8),
Solving, hL = 63.2 W/m2 · K (11.13 btu/h · ft 2 · °F). To solve for the flux q/A,

4 .5D. He at-Tr ansfe r  C oe fficie nt for  Tr ansition Flow  Insid e  a Pip e

In the transition region for a NRe between 2100 and 6000, the empirical equations are not well defined,
just as in the case of fluid friction factors. No simple equation exists for accomplishing a smooth
transition from heat transfer in laminar flow to that in turbulent flow, that is, a transition from Eq. (4.5-
4) at a NRe = 2100 to Eq. (4.5-8) at a NRe = 6000.

The plot in Fig. 4.5-2 represents an approximate relationship to use between the various heat-transfer
parameters and the Reynolds number between 2100 and 6000. For below a NRe, of 2100, the curves

represent Eq. (4.5-4), and above 104, Eq. (4.5-8). The mean ΔTa  of Eq. (4.5-7) should be used with the ha
in Fig. 4.5-2.

Figure 4.5-2. Correlation of heat-transfer parameters for transition region for Reynolds numbers between
2100 and 6000. (From R. H. Perry and C. H. Chilton, Chemical Engineers' Handbook. 5th ed. New York:
McGraw-Hill Book Company, 1973. With permission.)

4 .5E. He at-Tr ansfe r  C oe fficie nt for  Noncir cu lar  C ond u its

A heat-transfer system often used is one in which fluids flow at different temperatures in concentric
pipes. The heat-transfer coefficient of the fluid in the annular space can be predicted by using the same
equations as for circular pipes. However, the equivalent diameter defined in Section 2.10G must be used.
For an annular space, Deq is the ID of the outer pipe D1 minus the OD of the inner pipe D2. For other
geometries, an equivalent diameter can also be used.
EXAMPLE 4.5-2. Water Heated by Steam and Trial-and-
Error Solution
Water is flowing in a horizontal 1-in. schedule 40 steel pipe at an average temperature of
65.6°C and a velocity of 2.44 m/s. It is being heated by condensing steam at 107.8°C on the
outside of the pipe wall. The steam-side coefficient has been estimated as h0 = 10 500 W/m2 ·
K.

a.  Calculate the convective coefficient hi for water inside the pipe.

b.  Calculate the overall coefficient Ui based on the inside surface area.

c.  Calculate the heat-transfer rate q for 0.305 m of pipe with the water at an average
temperature of 65.6°C.

S olu t ion: From Appendix A.5, the various dimensions are Di = 0.0266 m and D0 = 0.0334
m. For water at a bulk average temperature of 65.6°C, from Appendix A.2, NPr  = 2.72, ρ =

0.980(1000) = 980 kg/m3, k = 0.633 W/m · K, and μ = 4.32 × 10-4 Pa · S = 4.32 × 10-4 kg/m ·
s.

The temperature of the inside metal wall is needed and will be assumed as about one-third the
difference between 65.6 and 107.8, or 80°C = Tw , for the first trial. Hence, μw  at 80°C = 3.56 ×

10-4 Pa · s.

First, the Reynolds number of the water is calculated at the bulk average temperature:

Hence, the flow is turbulent. Using Eq. (4.5-8) and substituting known values,

Solving, hL = hi = 13 324 W/m2 · K.

For part (b), the various areas are as follows for 0.305-m pipe:
The k for steel is 45.0 W/m · K. The resistances are

The overall temperature difference is (107.8 - 65.6)°C = 42.2°C = 42.2 K. The temperature
drop across the water film is

Hence, Tw  = 65.6 + 14.5 = 80.1°C. This is quite close to the original estimate of 80°C. The only
physical property changing in the second estimate would be μw . This would have a negligible
effect on hi, and a second trial is not necessary.

For part (b), the overall coefficient is, by Eq. (4.3-16),

For part (c), with the water at an average temperature of 65.6°C,
4 .5F. Entr ance -R e gion Effe ct on He at-Tr ansfe r  C oe fficie nt

Near the entrance of a pipe where the fluid is being heated, the temperature profile is not fully developed
and the local coefficient h is greater than the fully developed heat-transfer coefficient hL for turbulent
flow. At the entrance itself, where no temperature gradient has been established, the value of h is infinite.
The value of h drops rapidly and is approximately the same as hL at L/D ≅ 60, where L is the entrance
length. These relations for turbulent flow inside a pipe are as follows where the entrance is an abrupt
contraction:

Equation 4.5-12

Equation 4.5-13

where h is the average value for a tube of finite length L and hL is the value for a very long tube.

4 .5G . Liq u id -M e tals He at-Tr ansfe r  C oe fficie nt

Liquid metals are sometimes used as heat-transfer fluids in cases where a fluid is needed over a wide
temperature range at relatively low pressures. Liquid metals are often used in nuclear reactors and have
high heat-transfer coefficients as well as a high heat capacity per unit volume. The high heat-transfer
coefficients are due to the very high thermal conductivities and, hence, low Prandtl numbers. In liquid
metals in pipes, heat transfer by conduction is very important in the entire turbulent core because of the
high thermal conductivity and is often more important than the convection effects.

For fully developed turbulent flow in tubes with uniform heat flux, the following equation can be used
(L1):

Equation 4.5-14

where the Peclet number NPe = NReNPr . This holds for L/D > 60 and NPe between 100 and 104. For
constant wall temperatures,

Equation 4.5-15
for L/D > 60 and NPe > 100. All physical properties are evaluated at the average bulk temperature.

EXAMPLE 4.5-3. Liquid-Metal Heat Transfer Inside a Tube
A liquid metal flows at a rate of 4.00 kg/s through a tube having an inside diameter of 0.05 m.
The liquid enters at 500 K and is heated to 505 K in the tube. The tube wall is maintained at a
temperature of 30 K above the fluid bulk temperature and constant heat flux is also
maintained. Calculate the required tube length. The average physical properties are as follows:
μ = 7.1 × 10-4 Pa · s, ρ = 7400 kg/m3, cp = 120 J/kg · K, k = 13 W/m · K.

S olu t ion: The area is A = πD2/4 = π(0.05)2/4 = 1.963 × 10–3 m2. Then G = 4.0/1.963 × 10–3
= 2.038 × 103 kg/m2 · s. The Reynolds number is

Using Eq. (4.5-14),

Using a heat balance,

Equation 4.5-16

Substituting into Eq. (4.5-1),

Hence, A = 2400/75 360 = 3.185 × 10-2 m2. Then,
Solving, L = 0.203 m.

4 .5H. Log M e an Te m p e r atu r e  Diffe r e nce  and  Var ying Te m p e r atu r e  Dr op

Equations (4.5-1) and (4.3-12) as written apply only when the temperature drop (Ti − T0) is constant for
all parts of the heating surface. Hence, the equation

Equation 4.5-17

only holds at one point in the apparatus when the fluids are being heated or cooled. However, as the
fluids travel through the heat exchanger, they become heated or cooled and either Ti or T0 or both vary.
Then (Ti − T0) or ΔT varies with position, and some mean ΔTm must be used over the whole apparatus.

In a typical heat exchanger, a hot fluid inside a pipe is cooled from  to   by a cold fluid which is


flowing on the outside in a double pipe countercurrently (in the reverse direction) and is heated from T2
to T1, as shown in Fig. 4.5-3a. The ΔT shown is varying with distance. Hence, ΔT in Eq. (4.5-17) varies as
the area A goes from 0 at the inlet to A at the outlet of the exchanger.

Figure 4.5-3. Temperature profiles for one-pass double-pipe heat exchangers: (a) counter-current flow; (b)
cocurrent or parallel flow.

For countercurent flow of the two fluids as in Fig. 4.5-3a, the heat-transfer rate is

Equation 4.5-18
where ΔTm is a suitable mean temperature difference to be determined. For a dA area, a heat balance on
the hot and the cold fluids gives

Equation 4.5-19

where m is flow rate in kg/s. The values of m, m', cp,  , and U are assumed constant. Also,

Equation 4.5-20

From Eq. (4.5-19), dT' = -dq/  and dT = dq/mcp. Then,

Equation 4.5-21

Substituting Eq. (4.5-20) into (4.5-21),

Equation 4.5-22

Integrating between points 1 and 2,

Equation 4.5-23

Making a heat balance between the inlet and outlet,

Equation 4.5-24
Solving for   and mcp in Eq. (4.5-24) and substituting into Eq. (4.5-23),

Equation 4.5-25

Comparing Eqs. (4.5-18) and (4.5-25), we see that ΔTm is the log mean temperature difference ΔTlm.
Hence, in the case where the overall heat-transfer coefficient U is constant throughout the equipment and
the heat capacity of each fluid is constant, the proper temperature driving force to use over the entire
apparatus is the log mean driving force,

Equation 4.5-26

where

Equation 4.5-27

It can be also shown that for parallel flow, as pictured in Fig. 4.5-3b, the log mean temperature difference

should be used. In some cases, where steam is condensing,  and   may be the same. The equations


still hold for this case. When U varies with distance or other complicating factors occur, other references
should be consulted (B2, P3, W1).

EXAMPLE 4.5-4. Heat-Transfer Area and Log Mean
Temperature Difference
A heavy hydrocarbon oil which has a cpm = 2.30 kJ/kg · K is being cooled in a heat exchanger
from 371.9 K to 349.7 K and flows inside the tube at a rate of 3630 kg/h. A flow of 1450 kg
water/h enters at 288.6 K for cooling and flows outside the tube.

a.  Calculate the water outlet temperature and heat-transfer area if the overall Ui = 340

W/m2 · K and the streams are countercurrent.

b.  Repeat for parallel flow.

S olu t ion: Assume a cpm = 4.187 kJ/kg · K for water. The water inlet T2 = 288.6 K, outlet = T1;
oil inlet   = 371.9, outlet   = 349.7 K. Calculating the heat lost by the oil,

By a heat balance, the q must also equal the heat gained by the water:

Solving, T1 = 319.1 K.

To solve for the log mean temperature difference, ΔT2 =   − T2 = 349.7 − 288.6 = 61.1 K, ΔT1

=   - T1 = 371.9 - 319.1 = 52.8 K. Substituting into Eq. (4.5-27),

Using Eq. (4.5-26),

Solving, Ai = 2.66 m2.

For part (b), the water outlet is still T1 = 319.1 K. Referring to Fig. 4.5-3b, ΔT2 = 371.9 − 288.6
= 83.3K and ΔT1 = 349.7 - 319.1 = 30.6 K. Again, using Eq. (4.5-27) and solving, ΔTlm = 52.7

K. Substituting into Eq. (4.5-26), Ai = 2.87 m2. This is a larger area than for counterflow. This
occurs because counterflow gives larger temperature driving forces, and it is usually preferred
over parallel flow for this reason.

EXAMPLE 4.5-5. Laminar Heat Transfer and Trial and Error
A hydrocarbon oil at 150°F enters inside a pipe with an inside diameter of 0.0303 ft and a
length of 15 ft with a flow rate of 80 lbm/h. The inside pipe surface is assumed constant at
350°F, since steam is condensing outside the pipe wall, and has a very large heat-transfer
coefficient. The properties of the oil are cpm = 0.50 btu/lbm · °F and km = 0.083 btu/h · ft · °F.
The viscosity of the oil varies with temperature as follows: 150°F, 6.50 cp; 200°F, 5.05 cp;
250°F, 3.80 cp; 300°F, 2.82 cp; 350°F, 1.95 cp. Predict the heat-transfer coefficient and the oil
outlet temperature, Tbo.

S olu t ion: This is a trial-and-error solution since the outlet temperature of the oil Tbo is
unknown. The value of Tbo = 250°F will be assumed and checked later. The bulk mean
temperature of the oil to use for the physical properties is (150 + 250)/2 or 200°F. The
viscosity at 200°F is

At the wall temperature of 350°F,

The cross-section area of the pipe A is

The Reynolds number at the bulk mean temperature is

The Prandtl number is

Since the NRe is below 2100, the flow is in the laminar region and Eq. (4.5-4) will be used.
Even at the outlet temperature of 250°F, the flow is still laminar. Substituting,
Solving, ha  = 20.1 btu/h · ft 2 · °F (114 W/m2 · K). Next, making a heat balance on the oil,

Equation 4.5-28

Using Eq. (4.5-7)

Equation 4.5-7

For ΔTa ,

Equating Eq. (4.5-28) to (4.5-7) and substituting,

Solving, Tbo = 255°F.

This is higher than the assumed value of 250°F. For the second trial, the mean bulk
temperature of the oil would be (150 + 255)/2 or 202.5°F. The new viscosity is 5.0 cp compared
with 5.05 for the first estimate. This only affects the (μb/μw )0.14 factor in Eq. (4.5-4), since the
viscosity effect in the (NRe)(NPr ) factor cancels out. The heat-transfer coefficient will change by
less than 0.2%, which is negligible. Hence, the outlet temperature of T1 = 255°F (123.9°C) is
correct.
                             
                                                 
                                             
                                               
     

4.6. HEAT TRANSFER OUTSIDE VARIOUS GEOMETRIES IN
FORCED CONVECTION

4 .6 A. Intr od u ction

In many cases a fluid is flowing over completely immersed bodies such as spheres, tubes, plates, and so
on, and heat transfer is occurring between the fluid and the solid only. Many of these shapes are of
practical interest in process engineering. The sphere, cylinder, and flat plate are perhaps of greatest
importance, with heat transfer between these surfaces and a moving fluid frequently encountered.

When heat transfer occurs during immersed flow, the flux is dependent on the geometry of the body, the
position on the body (front, side, back, etc.), the proximity of other bodies, the flow rate, and the fluid
properties. The heat-transfer coefficient varies over the body. The average heat-transfer coefficient is
given in the empirical relationships to be discussed in the following sections.

In general, the average heat-transfer coefficient on immersed bodies is given by

Equation 4.6-1

where C and m are constants that depend on the various configurations. The fluid properties are
evaluated at the film temperature Tf = (Tw  + Tb)/2, where Tw  is the surface or wall temperature and Tb
the average bulk fluid temperature. The velocity in the NRe is the undisturbed free stream velocity v of the
fluid approaching the object.

4 .6 B. Flow  Par alle l to Flat Plate

When the fluid is flowing parallel to a flat plate and heat transfer is occurring between the whole plate of
length L m and the fluid, the NNu is as follows for a NRe,L below 3 × 105 in the laminar region and a NPr  >
0.7:

Equation 4.6-2

where NRe,L = Lνρ/μ and NNu = hL/k.

For the completely turbulent region at a NRe,L above 3 × 105 (K1, K3) and NPr  > 0.7,

Equation 4.6-3
However, turbulence can start at a NRe,L below 3 × 105 if the plate is rough (K3), and then Eq. (4.6-3) will

hold and give a NNu greater than that given by Eq. (4.6-2). For a NRe,L below about 2 × 104, Eq. (4.6-2)
gives the larger value of NNu.

EXAMPLE 4.6-1. Cooling a Copper Fin
A smooth, flat, thin fin of copper extending out from a tube is 51 mm by 51 mm square. Its
temperature is approximately uniform at 82.2°C. Cooling air at 15.6°C and 1 atm abs flows
parallel to the fin at a velocity of 12.2 m/s.

a.  For laminar flow, calculate the heat-transfer coefficient, h.

b.  If the leading edge of the fin is rough so that all of the boundary layer or film next to the
fin is completely turbulent, calculate h.

S olu t ion: The fluid properties will be evaluated at the film temperature Tf = (Tw  + Tb)/2:

The physical properties of air at 48.9°C from Appendix A.3 are k = 0.0280 W/m · K, ρ = 1.097
kg/m3, μ = 1.95 × 10-5 Pa · s, NPr  = 0.704. The Reynolds number is, for L = 0.051 m,

Substituting into Eq. (4.6-2),

Solving, h = 60.7 W/m2 · K (10.7 btu/h · ft 2 · °F).

For part (b), substituting into Eq. (4.6-3) and solving, h = 77.2 W/m2 · K (13.6 btu/h · ft 2 ·
°F).
4 .6 C . C ylind e r  w ith Axis Pe r p e nd icu lar  to Flow

Often a cylinder containing a fluid inside is being heated or cooled by a fluid flowing perpendicular to its
axis. The equation for predicting the average heat-transfer coefficient of the outside of the cylinder for
gases and liquids is (K3, P3) Eq. (4.6-1), with C and m as given in Table 4.6-1. The NRe = Dνρ/μ, where D
is the outside tube diameter and all physical properties are evaluated at the film temperature Tf. The
velocity is the undisturbed free stream velocity approaching the cylinder.

Figure 4.6-1. Nomenclature for banks of tubes in Table 4.6-2: (a) in-line tube rows, (b) staggered tube rows.

Table 4.6-1. Constants for Use in Eq. (4.6-1) for Heat Transfer to Cylinders with Axis
Perpendicular to Flow (NPr  > 0.6)

NRe m C

1–4 0.330 0.989


4–40 0.385 0.911
40−4 × 103 0.466 0.683

4 × 103 −4 × 104 0.618 0.193

4 × 104 −2.5 × 105 0.805 0.0266

4 .6 D. Flow  Past S ingle  S p he r e

When a single sphere is being heated or cooled by a fluid flowing past it, the following equation can be
used to predict the average heat-transfer coefficient for a NRe = Dνρ/μ of 1 to 70 000 and a NPr  of 0.6 to
400:

Equation 4.6-4
The fluid properties are evaluated at the film temperature Tf. A somewhat more accurate correlation,
which takes into account the effects of natural convection at these lower Reynolds numbers, is available
for a NRe range 1–17 000 from other sources (S2).

EXAMPLE 4.6-2. Cooling of a Sphere
Using the same conditions as Example 4.6-1, where air at 1 atm abs pressure and 15.6°C is
flowing at a velocity of 12.2 m/s, predict the average heat-transfer coefficient for air flowing
past a sphere having a diameter of 51 mm and an average surface temperature of 82.2°C.
Compare this with the value of h = 77.2 W/m2 · K for the flat plate in turbulent flow.

S olu t ion: The physical properties at the average film temperature of 48.9°C are the same as
for Example 4.6-1. The NRe is

Substituting into Eq. (4.6-4) for a sphere,

Solving, h = 56.1 W/m2 · K (9.88 btu/h · ft 2 · °F). This value is somewhat smaller than the
value of h = 77.2 W/m2 · K (13.6 btu/h · ft 2 · °F) for a flat plate.

4 .6 E. Flow  Past Banks of Tu b e s or  C ylind e r s

Many types of commercial heat exchangers are constructed with multiple rows of tubes, where the fluid
flows at right angles to the bank of tubes. An example is a gas heater in which a hot fluid inside the tubes
heats a gas passing over the outside of the tubes. Another example is a cold liquid stream inside the tubes
being heated by a hot fluid on the outside.

Figure 4.6-1 shows the arrangement for banks of tubes in-line and banks of tubes staggered, where D is
tube OD in m (ft), Sn  is distance m (ft) between the centers of the tubes normal to the flow, and Sp that
parallel to the flow. The open area to flow for in-line tubes is (Sn  − D) and (Sp − D); for staggered tubes it

is (Sn  − D) and (  − D). Values of C and m to be used in Eq. (4.6-1) for a Reynolds-number range of


2000 to 40 000 for heat transfer to banks of tubes containing more than 10 transverse rows in the
direction of flow are given in Table 4.6-2. For less than 10 rows, Table 4.6-3 gives correction factors.

Table 4.6-2. Values of C and m To Be Used in Eq. (4.6-1) for Heat Transfer to Banks of Tubes
Containing More Than 10 Transverse Rows
 

Arrangement C m C m C m

In-line 0.386 0.592 0.278 0.620 0.254 0.632

Staggered 0.575 0.556 0.511 0.562 0.535 0.556


Source: E. D. Grimison, Trans. ASME, 59, 583 (1937).

Table 4.6-3. Ratio of h for N Transverse Rows Deep to h for 10 Transverse Rows Deep (for Use
with Table 4.6-2)

N 1 2 3 4 5 6 7 8 9 10

Ratio for
staggered 0.68 0.75 0.83 0.89 0.92 0.95 0.97 0.98 0.99 1.00
tubes
Ratio for in-line
0.64 0.80 0.87 0.90 0.92 0.94 0.96 0.98 0.99 1.00
tubes
Source: W. M. Kays and R. K. Lo, Stanford Univ. Tech. Rept. 15, Navy Contract N6-ONR-251 T.O.6,
1952.

For cases where Sn /D and Sp/D are not equal to each other, the reader should consult Grimison (G1) for
more data. In baffled exchangers where there is normal leakage where all the fluid does not flow normal
to the tubes, the average values of h obtained should be multiplied by about 0.6 (P3). The Reynolds
number is calculated using the minimum area open to flow for the velocity. All physical properties are
evaluated at Tf.

EXAMPLE 4.6-3. Heating Air by a Bank of Tubes
Air at 15.6°C and 1 atm abs flows across a bank of tubes containing four transverse rows in the
direction of flow and 10 rows normal to the flow at a velocity of 7.62 m/s as the air approaches
the bank of tubes. The tube surfaces are maintained at 57.2°C. The outside diameter of the
tubes is 25.4 mm and the tubes are in-line to the flow. The spacing Sn  of the tubes normal to
the flow is 38.1 mm and Sp is also 38.1 mm parallel to the flow. For a 0.305-m length of the
tube bank, calculate the heat-transfer rate.

S olu t ion: Referring to Fig. 4.6-1a,

Since the air is heated in passing through the four transverse rows, an outlet bulk temperature
of 21.1°C will be assumed. The average bulk temperature is then
The average film temperature is

From Appendix A.3, for air at 37.7°C,

The ratio of the minimum-flow area to the total frontal area is (Sn  − D)/Sn . The maximum


velocity in the tube banks is then

For Sn /D = Sp/D = 1.5/1, the values of C and m from Table 4.6-2 are 0.278 and 0.620,
respectively. Substituting into Eq. (4.6-1) and solving for h,

This h is for 10 rows. For only four rows in the transverse direction, the h must be multiplied by
0.90, as given in Table 4.6-3.

Since there are 10 × 4 or 40 tubes, the total heat-transfer area per 0.305 m length is

The total heat-transfer rate q using an arithmetic average temperature difference between the
wall and the bulk fluid is
Next, a heat balance on the air is made to calculate its temperature rise ΔT using the
calculated q. First, the mass flow rate of air m must be calculated. The total frontal area of the
tube-bank assembly of 10 rows of tubes each 0.305 m long is

The density of the entering air at 15.6°C is ρ = 1.224 kg/m3. The mass flow rate m is

For the heat balance, the mean cp of air at 18.3°C is 1.0048 kJ/kg · K, and then

Solving, ΔT = 5.37°C.

Hence, the calculated outlet bulk gas temperature is 15.6 + 5.37 = 20.97°C, which is close to
the assumed value of 21.1°C. If a second trial were to be made, the new average Tb to use would
be (15.6 + 20.97)/2 or 18.28°C.

4 .6 F. He at Tr ansfe r  for  Flow  in Packe d  Be d s

Correlations for heat-transfer coefficients for packed beds are useful in designing fixed-bed systems such
as catalytic reactors, dryers for solids, and pebble-bed heat exchangers. In Section 3.1C the pressure drop
in packed beds was considered and discussions of the geometry factors in these beds were given. For
determining the rate of heat transfer in packed beds for a differential length dz in m,

Equation 4.6-5

where a is the solid-particle surface area per unit volume of bed in m-1, S the empty cross-sectional area
of bed in m2, T1 the bulk gas temperature in K. and T2 the solid surface temperature.

For the heat transfer of gases in beds of spheres (G2, G3) and a Reynolds number range of 10–10 000,

Equation 4.6-6

where ν' is the superficial velocity based on the cross section of the empty container in m/s [see Eq. (3.1-
11)], ε is the void fraction, NRe = DpG'/μf, and G' = v'ρ is the superficial mass velocity in kg/m2 · s. The
subscript f indicates properties evaluated at the film temperature, with others at the bulk temperature.
This correlation can also be used for a fluidized bed. An alternate equation to use in place of Eq. (4.6-6)
for fixed and fluidized beds is Eq. (7.3-36) for a Reynolds-number range of 10–4000. The term JH is
called the Colburn J factor and is defined as in Eq. (4.6-6) in terms of h.

Equations for heat transfer to noncircular cylinders such as hexagons and so forth are given elsewhere
(H1, J1, P3).
                             
                                                 
                                             
                                               
     

4.7. NATURAL CONVECTION HEAT TRANSFER

4 .7A. Intr od u ction

Natural convection heat transfer occurs when a solid surface is in contact with a gas or liquid which is at
a different temperature from the surface. Density differences in the fluid arising from the heating process
provide the buoyancy force required to move the fluid. Free or natural convection is observed as a result of
the motion of the fluid. An example of heat transfer by natural convection is a hot radiator used for
heating a room. Cold air encountering the radiator is heated and rises in natural convection because of
buoyancy forces. The theoretical derivation of equations for natural convection heat-transfer coefficients
requires the solution of motion and energy equations.

An important heat-transfer system occurring in process engineering is that in which heat is being
transferred from a hot vertical plate to a gas or liquid adjacent to it by natural convection. The fluid is not
moving by forced convection but only by natural or free convection. In Fig. 4.7-1 the vertical flat plate is
heated and the free convection boundary layer is formed. The velocity profile differs from that in a forced
convection system in that the velocity at the wall is zero and also is zero at the other edge of the boundary
layer, since the free stream velocity is zero for natural convection. The boundary layer initially is laminar
as shown, but at some distance from the leading edge it starts to become turbulent. The wall temperature
is Tw  K and the bulk temperature Tb.

Figure 4.7-1. Boundary-layer velocity  profile for natural convection heat tr ansfer fr om a heated, vertical plate.

The differential momentum-balance equation is written for the x and y directions for the control volume
(dx dy · 1). The driving force is the buoyancy force in the gravitational field and is due to the density
difference of the fluid. The momentum balance becomes

Equation 4.7-1
where ρb is the density at the bulk temperature Tb and ρ the density at T. The density difference can be
expressed in terms of the volumetric coefficient of expansion β and substituted back into Eq. (4.7-1):

Equation 4.7-2

For gases, β = 1/T. The energy-balance equation can be expressed as follows:

Equation 4.7-3

The solutions of these equations have been obtained by using integral methods of analysis discussed in
Section 3.10. Results have been obtained for a vertical plate, which is the simplest case and serves to
introduce the dimensionless Grashof number discussed below. However, in other physical geometries the
relations are too complex and empirical correlations have been obtained. These are discussed in the
following sections.

4 .7B. Natu r al C onv e ction fr om  Var iou s G e om e tr ie s

1. Na t u r a l conv ect ion fr om v er t ica l p la nes a nd  cy lind er s

For an isothermal vertical surface or plate with height L less than 1 m (P3), the average natural
convection heat-transfer coefficient can be expressed by the following general equation:

Equation 4.7-4

where a and m are constants from Table 4.7-1, NGr  the Grashof number, ρ density in kg/m3, μ viscosity
in kg/m · s, ΔT the positive temperature difference between the wall and bulk fluid or vice versa in K, k
the thermal conductivity in W/m · K, cp the heat capacity in J/kg · K, β the volumetric coefficient of

expansion of the fluid in 1/K [for gases β is 1/(TfK)], and g is 9.80665 m/s2. All the physical properties
are evaluated at the film temperature Tf = (Tw  + Tb)/2. In general, for a vertical cylinder with length L m,
the same equations can be used as for a vertical plate. In English units β is 1/(Tf °F + 460) in 1/°R and g
is 32.174 × (3600)2 ft/h2.

Table 4.7-1. Constants for Use with Eq. (4.7-4) for Natural Convection

Physical Geometry NGr NPr a m Ref.

Vertical planes and cylinders        
  [vertical height L < 1 m (3 ft)]        

   
<104 1.36 (P3)

    104 -109 0.59 (M1)

   
>109 0.13 (M1)

Horizontal cylinders        
  [diameter D used for L and D <        
0.20 m (0.66 ft)]

    <10-5 0.49 0 (P3)

    10-5 -10-3 0.71 (P3)

    10-3 -1 1.09 (P3)

   
1-104 1.09 (P3)

    104 -109 0.53 (M1)

    >109 0.13 (P3)

Horizontal plates        
  Upper surface of heated plates 105 -2 × 107  2 × 0.54 (M1)
or ower surface of cooled plates 0.14   (M1)
107 -3 × 1010

  Lower surface of heated plates
or upper surface of cooled plates 105 -1011 0.58 (F1)

The Grashof number can be interpreted physically as a dimensionless number that represents the ratio of
the buoyancy forces to the viscous forces in free convection and plays a role similar to that of the
Reynolds number in forced convection.

EXAMPLE 4.7-1. Natural Convection from Vertical Wall of
an Oven
A heated vertical wall 1.0 ft (0.305 m) high of an oven for baking food with the surface at
450°F (505.4 K) is in contact with air at 100°F (311 K). Calculate the heat-transfer coefficient
and the heat transfer/ft (0.305 m) width of wall. Note that heat transfer for radiation will not
be considered. Use English and SI units.

S olu t ion: The film temperature is
The physical properties of air at 275°F are k = 0.0198 btu/h · ft · °F, 0.0343 W/m · K; ρ =
0.0541 lbm/ft 3, 0.867 kg/m3; NPr  = 0.690; μ = (0.0232 cp) × (2.4191) = 0.0562 lbm/ft · h =

2.32 × 10-5 Pa · s; β = 1/408.2 = 2.45 × 10–3 K-1, β = 1/(460 + 275) = 1.36 × 10–3 °R-1; ΔT =
Tw  - Tb = 450 - 100 = 350°F (194.4 K). The Grashof number is, in English units,

In SI units,

The Grashof numbers calculated using English and SI units must, of course, be the same as
shown:

Hence, from Table 4.7-1, a = 0.59 and m =   for use in Eq. (4.7-4). Solving for h in Eq. (4.7-4)
and substituting known values,

For a 1-ft width of wall, A = 1 × 1 = 1.0 ft 2  (0.305 × 0.305 m2 ). Then

A considerable amount of heat will also be lost by radiation. This will be considered in Section
4.10.

Simplified equations for the natural convection heat transfer from air to vertical planes and cylinders at 1
atm abs pressure are given in Table 4.7-2. In SI units the equation for the range of NGr NPr  of 104 to 109 is

the one usually encountered, and this holds for (L3 ΔT) values below about 4.7 m3 · K and film
temperatures between 255 and 533 K. To correct the value of h to pressures other than 1 atm, the values of
h in Table 4.7-2 can be multiplied by (p/101.32)1/2 for NGr NPr  104 to 109 and by (p/101.32)2/3 for NGr NPr

> 109, where p = pressure in kN/m2. In English units the range of NGr NPr  of 104 to 109 is encountered

when (L3 ΔT) is less than about 300 ft 3 · °F. The value of h can be corrected to pressures other than 1.0
atm abs by multiplying the h at 1 atm by p1/2 for NGr NPr  of 104 to 109 and by p2/3 for NGr NPr  above 109,
where p = atm abs pressure. Simplified equations are also given for water and organic liquids.

Table 4.7-2. Simplified Equations for Natural Convection from Various Surfaces

      Equation

h = btu/h · ft2 · °F h = W/m 2  · K

L = ft , ΔT = °F L = m, ΔT = K


Physical Geometry NGr NPr D = ft D = m Ref.

Air at 101.32 pa (1 atm) abs pressure

Vertical planes and 104 -109  >109 h = 0.28(ΔT/L)1/4  h = h = 1.37(ΔT/L)1/4  h = (P1) (P1)


cylinders 0.18(ΔT)1/3 1.24 ΔT1/3

Horizontal cylinders 103 -109  >109 h = 0.27(ΔT/D)1/4  h = h = 1.32(ΔT/D)1/4  h = (M1) (M1)


0.18(ΔT)1/3 1.24 ΔT1/3

Horizontal plates        

  Heated plate facing 105 -2 × 107  2 × h = 0.2T(ΔT/L)1/4  h = h = 1.32(ΔT/L)1/4  h = (M1) (M1)


upward or cooled 107 -3 × 1010 0.22(ΔT)1/3 1.52 ΔT1/3
plate facing
downward
  Heated plate facing 3 × 105 -3 × h = 0.12(ΔT/L)1/4 h = 0.59(ΔT/L)1/4 (M1)
downward or 1010
cooled plate facing
upward

Water at 70°F (294 K)
Vertical planes and 104 -109 h = 26(ΔT/L)1/4 h = 12T(ΔT/L)1/4 (P1)
cylinders
Organic liquids at 70°F (294 K)
Vertical planes and 104 -109 h = 12(ΔT/L)1/4 h = 59(ΔT/L)1/4 (P1)
cylinders

EXAMPLE 4.7-2. Natural Convection and Simplified
Equation
Repeat Example 4.7-1 but use the simplified equation.

S olu t ion: The film temperature of 408.2 K is in the range 255–533 K. Also,
This is slightly greater than the value of 4.7 given as the approximate maximum for use of the
simplified equation. However, in Example 4.7-1 the value of NGr NPr  is below 109, so the
simplified equation from Table 4.7-2 will be used:

The heat-transfer rate q is

This value is reasonably close to the value of 127.1 W for Example 4.7-1.

2. Na t u r a l conv ect ion fr om hor izont a l cy lind er s

For a horizontal cylinder with an outside diameter of D m, Eq. (4.7-4) is used with the constants given in
Table 4.7-1. The diameter D is used for L in the equation. Simplified equations are given in Table 4.7-2.
The usual case for pipes is for the NGr NPr  range 104  to 109 (M1).

3. Na t u r a l conv ect ion fr om hor izont a l p la t es

For horizontal flat plates Eq. (4.7-4) is also used with the constants given in Table 4.7-1 and simplified
equations in Table 4.7-2. The dimension L to be used is the length of a side of a square plate, the linear
mean of the two dimensions for a rectangle, and 0.9 times the diameter of a circular disk.

4 . Na t u r a l conv ect ion in enclosed  sp a ces

Free convection in enclosed spaces occurs in a number of processing applications. One example is in an
enclosed double window in which two layers of glass are separated by a layer of air for energy
conservation. The flow phenomena inside these enclosed spaces are complex, since a number of different
types of flow patterns can occur. At low Grashof numbers the heat transfer is mainly by conduction
across the fluid layer. As the Grashof number is increased, different flow regimes are encountered.

The system for two vertical plates of height L m containing the fluid with a gap of δ m is shown in Fig.
4.7-2, where the plate surfaces are at temperatures T1 and T2. The Grashof number is defined as

Equation 4.7-5
Figure 4.7-2. Natural convection in enclosed vertical space.

The Nusselt number is defined as

Equation 4.7-6

The heat flux is calculated from

Equation 4.7-7

The physical properties are all evaluated at the mean temperature between the two plates. For gases
enclosed between vertical plates and L/δ > 3 (H1, J1, K1, P1),

Equation 4.7-8

Equation 4.7-9
Equation 4.7-10

For liquids in vertical plates,

Equation 4.7-11

Equation 4.7-12

For gases or liquids in a vertical annulus, the same equations hold as for vertical plates.

For gases in horizontal plates with the lower plate hotter than the upper,

Equation 4.7-13

Equation 4.7-14

For liquids in horizontal plates with the lower plate hotter than the upper (G5),

Equation 4.7-15

[View full size image]

EXAMPLE 4.7-3. Natural Convection in Enclosed Vertical
Space
Air at 1 atm abs pressure is enclosed between two vertical plates where L = 0.6 m and δ = 30
mm. The plates are 0.4 m wide. The plate temperatures are T1 = 394.3 K and T2 = 366.5 K.
Calculate the heat-transfer rate across the air gap.

S olu t ion: The mean temperature between the plates is used to evaluate the physical
properties: Tf = (T1 + T2)/2 = (394.3 + 366.5)/2 = 380.4 K. Also, δ = 30/1000 = 0.030 m.

From Appendix A.3, ρ = 0.9295 kg/m3, μ = 2.21 × 10-5 Pa · s, k = 0.03219 W/m · K, NPr  =

0.693, β = 1/Tf = 1/380.4 = 2.629 × 10–3 K-1.

5. Na t u r a l conv ect ion fr om ot her  sha p es

For spheres, blocks, and other types of enclosed air spaces, references elsewhere (H1, K1, M1, P1, P3)
should be consulted. In some cases when a fluid is forced over a heated surface at low velocity in the
laminar region, combined forced convection plus natural convection heat transfer occurs. For further
discussion of this, see (H1, K1, M1).
                             
                                                 
                                             
                                               
     

4.8. BOILING AND CONDENSATION

4 .8A. Boiling

1. M echa nisms of b oiling

Heat transfer to a boiling liquid is very important in evaporation and distillation as well as in other kinds
of chemical and biological processing, such as petroleum processing, control of the temperature of
chemical reactions, evaporation of liquid foods, and so on. The boiling liquid is usually contained in a
vessel with a heating surface of tubes or vertical or horizontal plates which supply the heat for boiling.
The heating surfaces can be heated electrically or by a hot or condensing fluid on the other side of the
heated surface.

In boiling, the temperature of the liquid is the boiling point of this liquid at the pressure in the
equipment. The heated surface is, of course, at a temperature above the boiling point. Bubbles of vapor
are generated at the heated surface and rise through the mass of liquid. The vapor accumulates in a vapor
space above the liquid level and is withdrawn.

Boiling is a complex phenomenon. Suppose we consider a small heated horizontal tube or wire immersed
in a vessel containing water boiling at 373.2 K (100°C). The heat flux is q/A W/m2; ΔT = Tw  − 373.2 K,

where Tw  is the tube or wire wall temperature; and h is the heat-transfer coefficient in W/m2 · K. Starting
with a low ΔT, the q/A and h values are measured. This is repeated at higher values of ΔT and the data
obtained are plotted as q/A versus ΔT, as shown in Fig. 4.8-1.

Figure 4.8-1. Boiling mechanisms for water at atm ospheric pressure, heat flux vs. temperature drop: (A)
natural convection, (B) nucleate boiling, (C) tr ansition boiling, (D) film boiling.
In the first region A of the plot in Fig. 4.8-1, at low temperature drops, the mechanism of boiling is
essentially that of heat transfer to a liquid in natural convection. The variation of h with ΔT0.25 is
approximately the same as that for natural convection to horizontal plates or cylinders. The very few
bubbles formed are released from the surface of the metal and rise without appreciably disturbing the
normal natural convection.

In the region B of nucleate boiling for a ΔT of about 5–25 K (9–45°F), the rate of bubble production
increases so that the velocity of circulation of the liquid increases. The heat-transfer coefficient h
increases rapidly and is proportional to ΔT2 to ΔT3 in this region.

In the region C of transition boiling, many bubbles are formed so quickly that they tend to coalesce and
form a layer of insulating vapor. Increasing the ΔT increases the thickness of this layer and the heat flux
and h drop as ΔT is increased. In the region D of film boiling, bubbles detach themselves regularly and
rise upward. At higher ΔT values radiation through thevapor layer next to the surface helps increase the
q /A and h. Similar-shaped curves are obtained for other shapes of surfaces (M1).

The curve of h versus ΔT has approximately the same shape as in Fig. 4.8-1. The values of h are quite
large. At the beginning of region B in Fig. 4.8-1 for nucleate boiling, h has a value of about 5700–11 400
W/m2 · K, or 1000–2000 btu/h · ft 2 · °F, and at the end of this region h has a peak value of almost 57
000 W/m2 · K, or 10 000 btu/hr · ft 2 · °F. These values are quite high, and in most cases the percent
resistance of the boiling film is only a few percent of the overall resistance to heat transfer.

The regions of commercial interest are the nucleate and film-boiling regions (P3). Nucleate boiling occurs
in kettle-type and natural-circulation reboilers.

2. Nu clea t e b oiling

In the nucleate-boiling region, the heat flux is affected by ΔT, pressure, nature and geometry of the
surface and system, and physical properties of the vapor and liquid. Equations have been derived by
Rohesenow et al. (P1). They apply to single tubes or flat surfaces and are quite complex.

Simplified empirical equations for estimating the boiling heat-transfer coefficients for water boiling on
the outside of submerged surfaces at 1.0 atm abs pressure have been developed (J2).

For a horizontal surface (SI and English units),

Equation 4.8-1

Equation 4.8-2

For a vertical surface,

Equation 4.8-3
Equation 4.8-4

where ΔT = Tw  - Tsat K or °F.

If the pressure is p atm abs, the values of h at 1 atm given above are multiplied by (p/1)0.4. Equations
(4.8-1) and (4.8-3) are in the natural convection region.

For forced convection boiling inside tubes, the following simplified relation can be used (J3):

Equation 4.8-5

where p in this case is in kPa (SI units) and psia (English units).

3. Film b oiling

In the film-boiling region, the heat-transfer rate is low in view of the large temperature drop used, which
is not utilized effectively. Film boiling has been subjected to considerable theoretical analysis. Bromley
(B3) gives the following equation to predict the heat-transfer coefficient in the film-boiling region on a
horizontal tube:

Equation 4.8-6

where kν  is the thermal conductivity of the vapor in W/m · K, ρν  the density of the vapor in kg/m3, ρl the

density of the liquid in kg/m3, hfg the latent heat of vaporization in J/kg, ΔT = Tw  - Tsat, Tsat the
temperature of saturated vapor in K, D the outside tube diameter in m, μν  the viscosity of the vapor in Pa

· s, and g the acceleration of gravity in m/s2. The physical properties of the vapor are evaluated at the
film temperature of Tf = (Tw  + Tsat)/2, and hfg at the saturation temperature. If the temperature
difference is quite high, some additional heat transfer occurs by radiation (H1).
EXAMPLE 4.8-1. Rate of Heat Transfer in a Jacketed Kettle
Water is being boiled at 1 atm abs pressure in a jacketed kettle with steam condensing in the
jacket at 115.6°C. The inside diameter of the kettle is 0.656 m and the height is 0.984 m. The
bottom is slightly curved but it will be assumed to be flat. Both the bottom and the sides up to
a height of 0.656 m are jacketed. The kettle surface for heat transfer is 3.2-mm stainless steel
with a k of 16.27 W/m · K. The condensing-steam coefficient hi inside the jacket has been

estimated as 10 200 W/m2 · K. Predict the boiling heat-transfer coefficient ho for the bottom
surface of the kettle.

S olu t ion: A diagram of the kettle is shown in Fig. 4.8-2. The simplified equations will be used
for the boiling coefficient ho. The solution is trial and error, since the inside metal surface
temperature Tw  is unknown. Assuming that Tw  = 110°C,

Figure 4.8-2. Steam-jacketed kettle and boiling water for Example 4.8-1.

Substituting into Eq. (4.8-2),

To check the assumed Tw , the resistance Ri of the condensing steam, Rw  of the metal wall, and


Ro of the boiling liquid must be calculated. Assuming equal areas of the resistances for A = 1

m2, then by Eq. (4.3-12),
The temperature drop across the boiling film is then

Hence, Tw  = 100 + 5.9 = 105.9°C. This is lower than the assumed value of 110°C.

For the second trial, Tw  = 108.3°C will be used. Then, ΔT = 108.3 − 100 = 8.3°C and, from Eq.

(4.8-2), the new ho = 3180. Calculating the new Ro = 31.44 × 10-5, and

and

This value is reasonably close to the assumed value of 108.3°C, so no further trials will be
made.

4 .8B. C ond e nsation

1. M echa nisms of cond ensa t ion

Condensation of a vapor to a liquid and vaporization of a liquid to a vapor both involve a change of phase
of a fluid with large heat-transfer coefficients. Condensation occurs when a saturated vapor such as
steam comes in contact with a solid whose surface temperature is below the saturation temperature, to
form a liquid such as water.

Normally, when a vapor condenses on a surface such as a vertical or horizontal tube or other surface, a
film of condensate is formed on the surface and flows over the surface by the action of gravity. It is this
film of liquid between the surface and the vapor that forms the main resistance to heat transfer. This is
called film-type condensation.

Another type of condensation, dropwise condensation, can occur, where small drops are formed on the
surface. These drops grow and coalesce, and the liquid flows from the surface. During this condensation,
large areas of tube are devoid of any liquid and are exposed directly to the vapor. Very high rates of heat
transfer occur on these bare areas. The average coefficient can be as high as 110 000 W/m2 · K (20 000
btu/h · ft 2 · °F), which is five to 10 times larger than film-type coefficients. Film-condensation
coefficients are normally much greater than those in forced convection and are on the order of magnitude
of several thousand W/m2 · K or more.

Dropwise condensation occurs on contaminated surfaces and when impurities are present. Film-type
condensation is more dependable and more common. Hence, for normal design purposes, film-type
condensation is assumed.

2. Film-cond ensa t ion coefficient s for  v er t ica l su r fa ces

Film-type condensation on a vertical wall or tube can be analyzed analytically by assuming laminar flow
of the condensate film down the wall. The film thickness is zero at the top of the wall or tube and
increases in thickness as it flows downward because of condensation. Nusselt (H1, W1) assumed that the
heat transfer from the condensing vapor at Tsat K, through this liquid film, and to the wall at Tw  K was
by conduction. Equating this heat transfer by conduction to that from condensation of the vapor, a final
expression can be obtained for the average heat-transfer coefficient over the whole surface.

In Fig. 4.8-3a, vapor at Tsat is condensing on a wall whose temperature is Tw  K. The condensate is
flowing downward in laminar flow. Assuming unit thickness, the mass of the element with liquid density
ρl in Fig. 4.8-3b is (δ − y)(dx · 1)ρl. The downward force on this element is the gravitational force minus
the buoyancy force, or (δ - y)(dx) × (ρl - ρν )g, where ρv  is the density of the saturated vapor. This force is
balanced by the viscous-shear force at the plane y of μl (dv/dy) (dx · 1). Equating these forces,

Equation 4.8-7

Figure 4.8-3. Film condensation on a vertical plate: (a) increase in film thickness with position, (b) balance on
element of condensate.
Integrating and using the boundary condition that ν = 0 at y = 0,

Equation 4.8-8

The mass flow rate of film condensate at any point x for unit depth is

Equation 4.8-9

Integrating,

Equation 4.8-10

At the wall, for area (dx · 1) m2, the rate of heat transfer is as follows if a linear temperature distribution is
assumed in the liquid between the wall and the vapor:

Equation 4.8-11
In a dx distance, the rate of heat transfer is qx. Also, in this dx distance, the increase in mass from
condensation is dm. Using Eq. (4.8-10),

Equation 4.8-12

Making a heat balance for dx distance, the mass flow rate dm times the latent heat hfg must equal the qx
from Eq. (4.8-11):

Equation 4.8-13

Integrating, with δ = 0 at x = 0 and δ = δ at x = x,

Equation 4.8-14

Using the local heat-transfer coefficient hx at x, a heat balance gives

Equation 4.8-15

This gives

Equation 4.8-16

Combining Eqs. (4.8-14) and (4.8-16),

Equation 4.8-17
By integrating over the total length L, the average value of h is obtained as follows:

Equation 4.8-18

Equation 4.8-19

However, for laminar flow, experimental data are about 20% above Eq. (4.8-19).

Hence, the final recommended expression for vertical surfaces in laminar flow is (M1)

Equation 4.8-20

where ρl is the density of liquid in kg/m3 and ρν  that of the vapor, g is 9.8066 m/s2, L is the vertical
height of the surface or tube in m, μl is the viscosity of liquid in Pa · s, kl is the liquid thermal
conductivity in W/m · K, ΔT = Tsat − Tw  in K, and hfg is the latent heat of condensation in J/kg at Tsat.
All physical properties of the liquid except hfg are evaluated at the film temperature Tf = (Tsat + TW)/2.
For long vertical surfaces the flow at the bottom can be turbulent. The Reynolds number is defined as

Equation 4.8-21

Equation 4.8-22

where m is total kg mass/s of condensate at tube or plate bottom and Г = m/πD or m/W. The NRe should
be below about 1800 for Eq. (4.8-20) to hold. The reader should note that some references define NRe as
Г/μ. Then this NRe should be below 450.
For turbulent flow for NRe > 1800 (M1),

Equation 4.8-23

Solution of this equation is by trial and error, since a value of NRe must first be assumed in order to
calculate h.

EXAMPLE 4.8-2. Condensation on a Vertical Tube
Steam saturated at 68.9 kPa (10 psia) is condensing on a vertical tube 0.305 m (1.0 ft) long
having an OD of 0.0254 m (1.0 in.) and a surface temperature of 86.11°C (187°F). Calculate
the average heat-transfer coefficient using English and SI units.

S olu t ion: From Appendix A.2,

Assuming a laminar film, using Eq. (4.8-20) in English as well as SI units, and neglecting ρν
as compared to ρl,
Solving, h = 2350 btu/h · ft 2 · °F = 13 350 W/m2 · K.

Next, the NRe will be calculated to see if laminar flow occurs as assumed. To calculate the total
heat transferred for a tube of area

Equation 4.8-24

However, this q must also equal that obtained by condensation of m lbm/h or kg/s. Hence,

Equation 4.8-25

Substituting the values given and solving for m,

Substituting into Eq. (4.8-21),

Hence, the flow is laminar as assumed.

3. Film-cond ensa t ion coefficient s ou t sid e hor izont a l cy lind er s


The analysis of Nusselt can also be extended to the practical case of condensation outside a horizontal
tube. For a single tube the film starts out with zero thickness at the top of the tube and increases in
thickness as it flows around to the bottom and then drips off. If there is a bank of horizontal tubes, the
condensate from the top tube drips onto the one below; and so on.

For a vertical tier of N horizontal tubes placed one below the other with outside tube diameter D (M1),

Equation 4.8-26

In most practical applications, the flow is in the laminar region and Eq. (4.8-26) holds (C3, M1).
                             
                                                 
                                             
                                               
     

4.9. HEAT EXCHANGERS

4 .9 A. Typ e s of Exchange r s

1. Int r od u ct ion

In the process industries the transfer of heat between two fluids is generally done in heat exchangers. The
most common type is one in which the hot and cold fluids do not come into direct contact with each
other but are separated by a tube wall or a flat or curved surface. The transfer of heat from the hot fluid to
the wall or tube surface is accomplished by convection, through the tube wall or plate by conduction, and
then by convection to the cold fluid. In the preceding sections of this chapter we have discussed the
calculation procedures for these various steps. Now we will discuss some of the types of equipment used
and overall thermal analyses of exchangers. Complete, detailed design methods have been highly
developed and will not be considered here.

2. Dou b le-p ip e he a t  excha ng er

The simplest exchanger is the double-pipe or concentric-pipe exchanger. This is shown in Fig. 4.9-1,
where one fluid flows inside one pipe and the other fluid flows in the annular space between the two
pipes. The fluids can be in cocurrent or countercurrent flow. The exchanger can be made from a pair of
single lengths of pipe with fittings at the ends or from a number of pairs interconnected in series. This
type of exchanger is useful mainly for small flow rates.

Figure 4.9-1. Flow in a double-pipe heat exchanger.

3. S he ll-a nd -t u b e excha ng er

If larger flows are involved, a shell-and-tube exchanger is used, which is the most important type of
exchanger in use in the process industries. In these exchangers the flows are continuous. Many tubes in
parallel are used, where one fluid flows inside these tubes. The tubes, arranged in a bundle, are enclosed
in a single shell and the other fluid flows outside the tubes in the shell side. The simplest shell-and-tube
exchanger is shown in Fig. 4.9-2a for one shell pass and one tube pass, or a 1-1 counterflow exchanger.
The cold fluid enters and flows inside through all the tubes in parallel in one pass. The hot fluid enters at
the other end and flows counterflow across the outside of the tubes. Cross-baffles are used so that the
fluid is forced to flow perpendicular across the tube bank rather than parallel with it. The added
turbulence generated by this cross-flow increases the shell-side heat-transfer coefficient.

Figure 4.9-2. Shell-and-tube heat exchangers: (a) 1 shell pass and 1 tube pass (1-1 exchanger); (b) 1 shell
pass and 2 tube passes (1–2 exchanger).

In Fig. 4.9-2b a 1-2 parallel-counterflow exchanger is shown. The liquid on the tube side flows in two
passes as shown and the shell-side liquid flows in one pass. In the first pass of the tube side, the cold
fluid is flowing counterflow to the hot shell-side fluid; in the second pass of the tube side, the cold fluid
flows in parallel (cocurrent) with the hot fluid. Another type of exchanger has two shell-side passes and
four tube passes. Other combinations of number of passes are also used sometimes, with the 1-2 and 2-4
types being the most common.

4 . C r oss-flow  excha ng er

When a gas such as air is being heated or cooled, a common device used is the cross-flow heat exchanger
shown in Fig. 4.9-3a. One of the fluids, which is a liquid, flows inside through the tubes, and the exterior
gas flows across the tube bundle by forced or sometimes natural convection. The fluid inside the tubes is
considered to be unmixed, since it is confined and cannot mix with any other stream. The gas flow
outside the tubes is mixed, since it can move about freely between the tubes, and there will be a tendency
for the gas temperature to equalize in the direction normal to the flow. For the unmixed fluid inside the
tubes, there will be a temperature gradient both parallel and normal to the direction of flow.
Figure 4.9-3. Flow patterns of cross-flow heat exchangers: (a) one fluid mixed (gas) and one fluid unmixed; (b)
both fluids unmixed.

A second type of cross-flow heat exchanger shown in Fig. 4.9-3b is typically used in air-conditioning and
space-heating applications. In this type the gas flows across a finned-tube bundle and is unmixed, since
it is confined in separate flow channels between the fins as it passes over the tubes. The fluid in the tubes
is unmixed.

Discussions of other types of specialized heat-transfer equipment will be deferred to Section 4.13. The
remainder of this section deals primarily with shell-and-tube and cross-flow heat exchangers.

4 .9 B. Log-M e an-Te m p e r atu r e -Diffe r e nce  C or r e ction Factor s

In Section 4.5H it was shown that when the hot and cold fluids in a heat exchanger are in true
countercurrent flow or in cocurrent (parallel) flow, the log mean temperature difference should be used:

Equation 4.9-1

where ΔT2 is the temperature difference at one end of the exchanger and ΔT1 at the other end. This ΔT1m
holds for a double-pipe heat exchanger and a 1-1 exchanger with one shell pass and one tube pass in
parallel or counterflow.

In cases where a multiple-pass heat exchanger is involved, it is necessary to obtain a different expression
for the mean temperature difference, depending on the arrangement of the shell and tube passes.
Considering first the one-shell-pass, two-tube-pass exchanger in Fig. 4.9-2b, the cold fluid in the first
tube pass is in counterflow with the hot fluid. In the second tube pass, the cold fluid is in parallel flow
with the hot fluid. Hence, the log mean temperature difference, which applies either to parallel or to
counterflow but not to a mixture of both types, as in a 1-2 exchanger, cannot be used to calculate the true
mean temperature drop without a correction.

The mathematical derivation of the equation for the proper mean temperature to use is quite complex.
The usual procedure is to use a correction factor FT which is so defined that when it is multiplied by the
ΔT1m, the product is the correct mean temperature drop ΔTm to use. In using the correction factors FT, it
is immaterial whether the warmer fluid flows through the tubes or the shell (K1). The factor FT has been
calculated (B4) for a 1-2 exchanger and is shown in Fig. 4.9-4a. Two dimensionless ratios are used as
follows:

Equation 4.9-2

Equation 4.9-3

Figure 4.9-4. Correction factor FT to log mean temperature difference: (a) 1-2 and 1-4 exchangers, (b) 2-4

exchangers. [From R. A. Bowman, A. C. Mueller, and W. M. Nagle, Trans. A.S.M.E., 62, 284, 285 (1940). With
permission.]
where Thi = inlet temperature of hot fluid in K (°F), Tho = outlet of hot fluid, Tci inlet of cold fluid, and Tco
= outlet of cold fluid.

In Fig. 4.9-4b, the factor FT (B4) for a 2-4 exchanger is shown. In general, it is not recommended to use a
heat exchanger for conditions under which FT < 0.75. Another shell-and-tube arrangement should be
used. Correction factors for two types of cross-flow exchanger are given in Fig. 4.9-5. Other types are
available elsewhere (B4, P1).

Figure 4.9-5. Correction factor FT to log mean temperature difference for cross-flow exchangers [Z = (Thi  −

Tho )/(Tc o  − Tc i )]: (a) single pass, shell fluid mixed, other fluid unmixed, (b) single pass, both fluids unmixed.


[From R. A. Bowman, A. C. Mueller, and W. M. Nagle, Trans. A.S.M.E., 62, 288, 289 (1940). With permission.]
Using the nomenclature of Eqs. (4.9-2) and (4.9-3), the ΔT1m of Eq. (4.9-1) can be written as

Equation 4.9-4

Then the equation for an exchanger is

Equation 4.9-5

where

Equation 4.9-6

EXAMPLE 4.9-1. Temperature Correction Factor for a Heat
Exchanger
A 1-2 heat exchanger containing one shell pass and two tube passes heats 2.52 kg/s of water
from 21.1 to 54.4°C by using hot water under pressure entering at 115.6 and leaving at 48.9°C.
The outside surface area of the tubes in the exchanger is Ao = 9.30 m2.

a.  Calculate the mean temperature difference ΔTm in the exchanger and the overall heat-
transfer coefficient Uo.

b.  For the same temperatures but using a 2-4 exchanger, what would be the ΔTm?

S olu t ion: The temperatures are as follows:
First making a heat balance on the cold water, assuming a cpm of water of 4187 J/kg · K and
Tco − Tci = (54.4 − 21.1)°C = 33.3°C = 33.3 K,

The log mean temperature difference using Eq. (4.9-4) is

Next, substituting into Eqs. (4.9-2) and (4.9-3),

Equation 4.9-2

Equation 4.9-3

From Fig. 4.9-4a, FT = 0.74. Then, by Eq. (4.9-6),

Equation 4.9-6

Rearranging Eq. (4.9-5) to solve for Uo and substituting the known values, we have

For part (b), using a 2-4 exchanger and Fig. 4.9-4b, FT = 0.94. Then,
Hence, in this case the 2-4 exchanger utilizes more of the available temperature driving force.

4 .9 C . He at-Exchange r  Effe ctiv e ne ss

1. Int r od u ct ion

In the preceding section the log mean temperature difference was used in the equation q = UA ΔT1m in
the design of heat exchangers. This form is convenient when the inlet and outlet temperatures of the two
fluids are known or can be determined by a heat balance. Then the surface area can be determined if U is
known. However, when the temperatures of the fluids leaving the exchanger are not known and a given
exchanger is to be used, a tedious trial-and-error procedure is necessary. To solve these cases, a method
called the heat-exchanger effectiveness ε is used which does not involve any of the outlet temperatures.

The heat-exchanger effectiveness is defined as the ratio of the actual rate of heat transfer in a given
exchanger to the maximum possible amount of heat transfer if an infinite heat-transfer area were
available. The temperature profile for a counterflow heat exchanger is shown in Fig. 4.9-6.

Figure 4.9-6. Temperature profile for countercurrent heat exchanger.

2. Der iv a t ion of effect iv eness eq u a t ion

The heat balance for the cold (C) and hot (H) fluids is

Equation 4.9-7

Calling (mcp)H = C H and (mcp)c = C C, then in Fig. 4.9-6, C H > C C, and the cold fluid undergoes a greater


temperature change than the hot fluid. Hence, we designate C C as C min  or minimum heat capacity.
Then, if there is an infinite area available for heat transfer, TCo = THi. Then the effectiveness ε is

Equation 4.9-8
If the hot fluid is the minimum fluid, THo = TCi, and

Equation 4.9-9

In both equations the denominators are the same and the numerator gives the actual heat transfer:

Equation 4.9-10

Note that Eq. (4.9-10) uses only inlet temperatures, which is an advantage when inlet temperatures are
known and it is desired to predict the outlet temperatures for a given existing exchanger.

For the case of a single-pass, counterflow exchanger, combining Eqs. (4.9-8) and (4.9-9),

Equation 4.9-11

We consider first the case when the cold fluid is the minimum fluid. Rewriting Eq. (4.5-25) using the
present nomenclature,

Equation 4.9-12

Combining Eq. (4.9-7) with the left side of Eq. (4.9-11) and solving for THi,

Equation 4.9-13

Subtracting TCo from both sides,

Equation 4.9-14
From Eq. (4.9-7) for C min  = C C and C max = C H,

Equation 4.9-15

This can be rearranged to give the following:

Equation 4.9-16

Substituting Eq. (4.9-13) into (4.9-16),

Equation 4.9-17

Finally, substituting Eqs. (4.9-14) and (4.9-17) into (4.9-12), rearranging, taking the antilog of both
sides, and solving for ε,

Equation 4.9-18

We define NTU as the number of transfer units as follows:

Equation 4.9-19

The same result would have been obtained if C H = C min . For parallel flow we obtain

Equation 4.9-20
In Fig. 4.9-7, Eqs. (4.9-18) and (4.9-20) have been plotted in convenient graphical form. Additional
charts are available for different shell-and-tube and cross-flow arrangements (K1).

Figure 4.9-7. Heat-exchanger effectiveness ε: (a) counterflow exchanger, (b) parallel flow exchanger.

EXAMPLE 4.9-2. Effectiveness of Heat Exchanger
Water flowing at a rate of 0.667 kg/s enters a countercurrent heat exchanger at 308 K and is
heated by an oil stream entering at 383 K at a rate of 2.85 kg/s (cp = 1.89 kJ/kg · K). The

overall U = 300 W/m2 · K and the area A = 15.0 m2. Calculate the heat-transfer rate and the
exit water temperature.

S olu t ion: Assuming that the exit water temperature is about 370 K, the cp for water at an
average temperature of (308 + 370)/2 = 339 K is 4.192 kJ/kg · K (Appendix A.2). Then, (mcp)H

= C H = 2.85(1.89 × 103) = 5387 W/K and (mcp)C = C C = 0.667(4.192 × 103) = 2796 W/K =


C min . Since C C is the minimum, C min /C max = 2796/5387 = 0.519.

Using Eq. (4.9-19), NTU = UA/C min  = 300(15.0)/2796 = 1.607. Using Fig. (4.9-7a) for a


counterflow exchanger, ε = 0.71. Substituting into Eq. (4.9-10),
Using Eq. (4.9-7),

Solving, TCo = 361.3 K.

4 .9 D. Fou ling Factor s and  Typ ical Ov e r all U Valu e s

In actual practice, heat-transfer surfaces do not remain clean. Dirt, soot, scale, and other deposits form
on one or both sides of the tubes of an exchanger and on other heat-transfer surfaces. These deposits offer
additional resistance to the flow of heat and reduce the overall heat-transfer coefficient U. In petroleum
processes coke and other substances can deposit. Silting and deposits of mud and other materials can
occur. Corrosion products which could constitute a serious resistance to heat transfer may form on the
surfaces. Biological growth such as algae can occur with cooling water and in the biological industries.

To avoid or lessen these fouling problems, chemical inhibitors are often added to minimize corrosion, salt
deposition, and algae growth. Water velocities above 1 m/s are generally used to help reduce fouling.
Large temperature differences may cause excessive deposition of solids on surfaces and should be
avoided if possible.

The effect of such deposits and fouling is usually taken care of in design by adding a term for the
resistance of the fouling on the inside and outside of the tube in Eq. (4.3-17) as follows:

Equation 4.9-21

where hdi is the fouling coefficient for the inside and hdo the fouling coefficient for the outside of the tube

in W/m2 · K. A similar expression can be written for U0 using Eq. (4.3-18).

Fouling coefficients recommended for use in designing heat-transfer equipment are available in many
references (P3, N1). A short tabulation of some typical fouling coefficients is given in Table 4.9-1.

Table 4.9-1. Typical Fouling Coefficients (P3, N1)

  hd  (W/m 2  · K) hd  (btu/h · ft 2  · °F)

Distilled and seawater 11 350 2000


City water 5680 1000

Muddy water 1990–2840 350–500

Gases 2840 500


Vaporizing liquids 2840 500

Vegetable and gas oils 1990 350


In order to perform preliminary estimates of sizes of shell-and-tube heat exchangers, typical values of
overall heat-transfer coefficients are given in Table 4.9-2. These values should be useful as a check on the
results of the design methods described in this chapter.

Table 4.9-2. Typical Values of Overall Heat-Transfer Coefficients in Shell-and-Tube Exchangers
(H1, P3, W1)

  U U

  (W/m 2 · K) (btu/h · ft 2  · °F)

Water to water 1140–1700 200–300

Water to brine 570–1140 100–200

Water to organic liquids 570–1140 100–200


Water to condensing steam 1420–2270 250–400
Water to gasoline 340–570 60–100

Water to gas oil 140–340 25–60

Water to vegetable oil 110–285 20–50


Gas oil to gas oil 110–285 20–50

Steam to boiling water 1420–2270 250–400

Water to air (finned tube) 110–230 20–40

Light organics to light organics 230–425 40–75

Heavy organics to heavy organics 55–230 10–40


                             
                                                 
                                             
                                               
     

4.10. INTRODUCTION TO RADIATION HEAT TRANSFER

4 .10A. Intr od u ction and  Basic Eq u ation for  R ad iation

1. Na t u r e of r a d ia nt  he a t  t r a nsfer

In the preceding sections of this chapter we have studied conduction and convection heat transfer. In
conduction, heat is transferred from one part of a body to another, and the intervening material is
heated. In convection, heat is transferred by the actual mixing of materials and by conduction. In radiant
heat transfer, the medium through which the heat is transferred usually is not heated. Radiation heat
transfer is the transfer of heat by electromagnetic radiation.

Thermal radiation is a form of electromagnetic radiation similar to X rays, light waves, gamma rays, and
so on, differing only in wavelength. It obeys the same laws as light: It travels in straight lines, can be
transmitted through space and vacuum, and so on. It is an important mode of heat transfer and is
especially important where large temperature differences occur, as, for example, in a furnace with boiler
tubes, in radiant dryers, or in an oven baking food. Radiation often occurs in combination with
conduction and convection. An elementary discussion of radiant heat transfer will be given here, with a
more advanced and comprehensive discussion being given in Section 4.11.

In an elementary sense the mechanism of radiant heat transfer is composed of three distinct steps or
phases:

1.  The thermal energy of a hot source, such as the wall of a furnace at T1, is converted into energy in
the form of electromagnetic-radiation waves.

2.  These waves travel through the intervening space in straight lines and strike a cold object at T2,
such as a furnace tube containing water to be heated.

3.  The electromagnetic waves that strike the body are absorbed by the body and converted back to
thermal energy or heat.

2. Ab sor p t iv it y  a nd  b la ck  b od ies

When thermal radiation (such as light waves) falls upon a body, part is absorbed by the body in the form
of heat, part is reflected back into space, and part may actually be transmitted through the body. For
most cases in process engineering, bodies are opaque to transmission, so this will be neglected. Hence, for
opaque bodies,

Equation 4.10-1

where α is absorptivity or fraction absorbed and ρ is reflectivity or fraction reflected.
A black body is defined as one that absorbs all radiant energy and reflects none. Hence, ρ = 0 and α = 1.0
for a black body. Actually, in practice there are no perfect black bodies, but a close approximation is a
small hole in a hollow body, as shown in Fig. 4.10-1. The inside surface of the hollow body is blackened
by charcoal. The radiation enters the hole and impinges on the rear wall; part is absorbed there and part
is reflected in all directions. The reflected rays impinge again, part is absorbed, and the process
continues. Hence, essentially all of the energy entering is absorbed and the area of the hole acts as a
perfect black body. The surface of the inside walls is "rough" and rays are scattered in all directions,
unlike a mirror, where they are reflected at a definite angle.

Figure 4.10-1. Concept of a perfect black body.

As stated previously, a black body absorbs all radiant energy falling on it and reflects none. Such a black
body also emits radiation, depending on its temperature, and does not reflect any. The ratio of the
emissive power of a surface to that of a black body is called emissivity ε and is 1.0 for a black body.
Kirchhoff's law states that at the same temperature T1, α1 and ε1 of a given surface are the same, or

Equation 4.10-2

Equation (4.10-2) holds for any black or nonblack solid surface.

3. R a d ia t ion fr om a  b od y  a nd  emissiv it y

The basic equation for heat transfer by radiation from a perfect black body with an emissivity ε = 1.0 is

Equation 4.10-3

where q is heat flow in W, A is m2 surface area of body, σ is a constant 5.676 × 10-8 W/m2 · K4 (0.1714 X
10-8 btu/h · ft 2 · °R4), and T is temperature of the black body in K (°R).

For a body that is not a black body and has an emissivity ε < 1.0, the emissive power is reduced by ε, or

Equation 4.10-4
Substances that have emissivities of less than 1.0 are called gray bodies when the emissivity is
independent of the wavelength. All real materials have an emissivity ε < 1.

Since the emissivity ε and absorptivity α of a body are equal at the same temperature, the emissivity, like
absorptivity, is low for polished metal surfaces and high for oxidized metal surfaces. Typical values are
given in Table 4.10-1 but do vary some with temperature. Most non-metallic substances have high
values. Additional data are tabulated in Appendix A.3.

Table 4.10-1. Total Emissivity, ε, of Various Surfaces

Surface T(K) T(°F) Emissivity, ε

Polished aluminum 500 850 440 1070 0.039 0.057

Polished iron 450 350 0.052


Oxidized iron 373 212 0.74

Polished copper 353 176 0.018

Asbestos board 296 74 0.96

Oil paints, all colors 373 212 0.92–0.96

Water 273 32 0.95

4 .10B. R ad iation to a S m all Ob je ct fr om  S u r r ou nd ings

In the case of a small gray object of area A1 m2 at temperature T1 in a large enclosure at a higher
temperature T2, there is a net radiation to the small object. The small body emits an amount of radiation

to the enclosure given by Eq. (4.10-4) as  . The emissivity ε1 of this body is taken at T1. The

small body also absorbs an amount of energy from the surroundings at T2 given by  . The α12
is the absorptivity of body 1 for radiation from the enclosure at T2. The value of α12 is approximately the
same as the emissivity of this body at T2. The net heat of absorption is then, by the Stefan-Boltzmann
equation,

Equation 4.10-5

A further simplification of Eq. (4.10-5) is usually made for engineering purposes by using only one
emissivity for the small body, at temperature T2. Thus,

Equation 4.10-6
EXAMPLE 4.10-1. Radiation to a Metal Tube
A small oxidized horizontal metal tube with an OD of 0.0254 m (1 in.), 0.61 m (2 ft) long, and
with a surface temperature at 588 K (600°F) is in a very large furnace enclosure with fire-brick
walls and the surrounding air at 1088 K (1500°F). The emissivity of the metal tube is 0.60 at
1088 K and 0.46 at 588 K. Calculate the heat transfer to the tube by radiation using SI and
English units.

S olu t ion: Since the large-furnace surroundings are very large compared to the small enclosed
tube, the surroundings, even if gray, when viewed from the position of the small body appear
black, and Eq. (4.10-6) is applicable. Substituting given values into Eq. (4.10-6) with an ε of
0.6 at 1088 K,

Other examples of small objects in large enclosures occurring in the process industries are a
loaf of bread in an oven receiving radiation from the walls around it, a package of meat or food
radiating heat to the walls of a freezing enclosure, a hot ingot of solid iron cooling and
radiating heat in a large room, and a thermometer measuring the temperature in a large duct.

4 .10C . C om b ine d  R ad iation and  C onv e ction He at Tr ansfe r

When radiation heat transfer occurs from a surface, it is usually accompanied by convective heat
transfer, unless the surface is in a vacuum. When the radiating surface is at a uniform temperature, we
can calculate the heat transfer for natural or forced convection using the methods described in the
previous sections of this chapter. The radiation heat transfer is calculated by the Stefan-Boltzmann
equation (4.10-6). Then the total rate of heat transfer is the sum of convection plus radiation.

As discussed before, the heat-transfer rate by convection and the convective coefficient are given by

Equation 4.10-7

where qconv  is the heat-transfer rate by convection in W, hc the natural or forced convection coefficient in

W/m2 · K, T1 the temperature of the surface, and T2 the temperature of the air and the enclosure. A

radiation heat-transfer coefficient hr  in W/m2 · K can be defined as

Equation 4.10-8
where qrad is the heat-transfer rate by radiation in W. The total heat transfer is the sum of Eqs. (4.10-7)
and (4.10-8),

Equation 4.10-9

To obtain an expression for hr , we equate Eq. (4.10-6) to (4.10-8) and solve for hr :

Equation 4.10-10

A convenient chart giving values of hr  in English units calculated from Eq. (4.10-10) with ε = 1.0 is given
in Fig. 4.10-2. To use values from this figure, the value obtained from the figure should be multiplied by ε
to give the value of hr  to use in Eq. (4.10-9). If the air temperature is not the same as T2 of the enclosure,
Eqs. (4.10-7) and (4.10-8) must be used separately and not combined together as in (4.10-9).

Figure 4.10-2. Radiation heat-transfer coefficient as a function of temperature. (From R. H. Perry and C. H.
Chilton, Chemical Engineers' Handbook, 5th ed. New York: McGraw-Hill Book Company, 1973. With
permission.)
EXAMPLE 4.10-2. Combined Convection Plus Radiation
from a Tube
Recalculate Example 4.10-1 for combined radiation plus natural convection to the horizontal
0.0254-m tube.

S olu t ion: The area A of the tube = π(0.0254)(0.61) = 0.0487 m2. For the natural convection
coefficient to the 0.0254-m horizontal tube, the simplified equation from Table 4.7-2 will be
used as an approximation even though the film temperature is quite high:

Substituting the known values,

Using Eq. (4.10-10) and ε = 0.6,
Substituting into Eq. (4.10-9),

Hence, the heat loss of -2130 W for radiation is increased to only -2507 W when natural
convection is also considered. In this case, because of the large temperature difference,
radiation is the most important factor.

Perry and Green (P3, pp. 10-14) give a convenient table of natural convection plus radiation
coefficients (hc + hr ) from single horizontal oxidized steel pipes as a function of the outside
diameter and temperature difference. The coefficients for insulated pipes are about the same as
those for a bare pipe (except that lower surface temperatures are involved for the insulated
pipes), since the emissivity of cloth insulation wrapping is about that of oxidized steel,
approximately 0.8. A more detailed discussion of radiation will be given in Section 4.11.

4 .10D. Effe ct of R ad iation on Te m p e r atu r e  M e asu r e m e nt of a G as

When a temperature sensor or probe (thermometer, thermocouple, etc.) is used to measure the
temperature of a gas flowing in an enclosure, significant errors can occur. Radiation heat exchange will
take place between the sensor and the wall and convection heat transfer between the sensor and the gas.
The sensor will indicate a temperature between the true gas and wall surface temperatures. This is shown
in Fig. 4.10-3, where the wall temperature Tw  is less than the true gas temperature Tg.

Figure 4.10-3. Temperature measurement of a gas showing radiation and convection heat transfer for a bare
probe and a shielded probe.

The equations for the heat transfer qc by convection to the probe and radiation qr  from the probe to the
wall are as follows for Tw  < Tg:
Equation 4.10-11

where Ap is the area of the tube in m2 and ε is the emissivity of the probe.

EXAMPLE 4.10-3. Effect of Radiation on Temperature
Measurement in a Gas
A thermocouple is measuring the temperature of hot air flowing in a pipe whose walls are at
Tw  = 400 K (260°F). The true gas temperature Tg = 465 K (377°F). Calculate the temperature
Tp indicated by the thermocouple. The emissivity of the probe is assumed as ε = 0.6 and the

convection heat-transfer coefficient hc = 40 W/m2 · K.

S olu t ion: Substituting into Eq. (4.10-11) for convection, qc, and for radiation, qr ,

Equating qc = qr , canceling out the term Ap, and solving by trial and error, Tp = 451.4 K.
Hence, the thermocouple reading of Tp = 451.4 K (352.5°F) is 13.6 K (24.5°F) lower than the
true gas temperature of 465 K (377°F).

Probes with a radiation shield as shown in Fig. 4.10-3 are often used to reduce radiation errors. The
shield will have a temperature which is closer to the gas temperature than is the wall. Since the probe
now radiates heat to a surface which is closer to the gas temperature, the radiation loss is less. It can be
shown that with one shield, the radiation heat loss will be halved. Multiple shields can be used to further
reduce the error. Using a polished surface on the probe to reduce the emissivity lowers the radiation heat
loss. This also reduces the measurement error.
                             
                                                 
                                             
                                               
     

4.11. ADVANCED RADIATION HEAT­TRANSFER PRINCIPLES

4 .11A. Intr od u ction and  R ad iation S p e ctr u m

1. Int r od u ct ion

This section will cover some basic principles together with some advanced topics on radiation that were
not covered in Section 4.10. The exchange of radiation between two surfaces depends upon the size,
shape, and relative orientation of these two surfaces and also upon their emissivities and absorptivities.
In the cases to be considered the surfaces are separated by nonabsorbing media such as air. When gases
such as CO2 and H2O vapor are present, some absorption by the gases occurs, which is not considered
until later in this section.

2. R a d ia t ion sp ect r u m a nd  t he r ma l r a d ia t ion

Energy can be transported in the form of electromagnetic waves, which travel at the speed of light. Bodies
may emit many forms of radiant energy, such as gamma rays, thermal energy, radio waves, and so on. In
fact, there is a continuous spectrum of electromagnetic radiation. This electromagnetic spectrum is
divided into a number of wavelength ranges, such as cosmic rays (λ < 10-13 m), gamma rays (λ = 10-13 to
10–10 m), thermal radiation (λ = 10-7  to 10-4 m), and so on. The electromagnetic radiation produced
solely because of the temperature of the emitter is called thermal radiation and exists between the
wavelengths of 10-7  and 10-4 m. This portion of the electromagnetic spectrum is of importance in radiant
thermal heat transfer. Electromagnetic waves having wavelengths between 3.8 × 10-7  and 7.6 × 10-7  m,
called visible radiation, can be detected by the human eye. This visible radiation lies within the thermal
radiation range.

When different surfaces are heated to the same temperature, they do not all emit or absorb the same
amount of thermal radiant energy. A body that absorbs and emits the maximum amount of energy at a
given temperature is called a black body. A black body is a standard to which other bodies can be
compared.

3. Pla nck 's la w  a nd  emissiv e p ow er

When a black body is heated to a temperature T, photons are emitted from the surface which have a
definite distribution of energy. Planck's equation relates the monochromatic emissive power EBλ in W/m3
at a temperature T in K and a wavelength λ in m:

Equation 4.11-1
A plot of Eq. (4.11-1) is given in Fig. 4.11-1 and shows that the energy given off increases with T. Also, for
a given T, the emissive power reaches a maximum value at a wavelength that decreases as the
temperature T increases. At a given temperature the radiation emitted extends over a spectrum of
wavelengths. The visible-light spectrum occurs in the low λ region. The sun has a temperature of about
5800 K and the solar spectrum straddles this visible range.

Figure 4.11-1. Spectral distribution of total energy emitted by a black body at various temperatures of the
black body.

For a given temperature, the wavelength at which the black-body emissive power is a maximum can be
determined by differentiating Eq. (4.11-1) with respect to λ at constant T and setting the result equal to
zero. The result is as follows and is known as Wien's displacement law:

Equation 4.11-2

The locus of the maximum values is shown in Fig. 4.11-1.

4 . S t efa n-Bolt zma nn la w

The total emissive power is the total amount of radiation energy per unit area leaving a surface with
temperature T over all wavelengths. For a black body, the total emissive power is given by the integral of
Eq. (4.11-1) at a given T over all wavelengths, or the area under the curve in Fig. 4.11-1:
Equation 4.11-3

This gives

Equation 4.11-4

The result is the Stefan-Boltzmann law with σ = 5.676 × 10-8 W/m2 · K4. The units of EB are W/m2.

5. Emissiv it y  a nd  K ir chhoff's la w

An important property in radiation is the emissivity of a surface. The emissivity ε of a surface is defined
as the total emitted energy of the surface divided by the total emitted energy of a black body at the same
temperature:

Equation 4.11-5

Since a black body emits the maximum amount of radiation, ε is always <1.0.

We can derive a relationship between the absorptivity α1 and emissitivy ε1 of a material by placing this
material in an isothermal enclosure and allowing the body and enclosure to reach the same temperature
at thermal equilibrium. If G is the irradiation on the body, the energy absorbed must equal the energy
emitted:

Equation 4.11-6

If this body is removed and replaced by a black body of equal size, then at equilibrium,

Equation 4.11-7

Dividing Eq. (4.11-6) by (4.11-7),

Equation 4.11-8
But α2 = 1.0 for a black body. Hence, since E1/EB = ε1,

Equation 4.11-9

This is Kirchhoff's law, which states that at thermal equilibrium α = ε of a body. When a body is not at
equilibrium with its surroundings, the result is not valid.

6 . C oncep t  of g r a y  b od y

A gray body is defined as a surface for which the monochromatic properties are constant over all
wavelengths. For a gray surface,

Equation 4.11-10

Hence, the total absorptivity a and the monochromatic absorptivity αλ of a gray surface are equal, as are
ε and ελ:

Equation 4.11-11

Applying Kirchhoff's law to a gray body, αλ = ελ and

Equation 4.11-12

As a result, the total absorptivity and emissivity are equal for a gray body even if the body is not in
thermal equilibrium with its surroundings.

Gray bodies do not exist in practice; the concept of a gray body is an idealized one. The absorptivity of a
surface actually varies with the wavelength of the incident radiation. Engineering calculations can often
be based on the assumption of a gray body with reasonable accuracy. The a is assumed constant even
with a variation in λ of the incident radiation. Also, in actual systems, various surfaces may be at
different temperatures. In these cases, α for a surface is evaluated by determining the emissivity not at
the actual surface temperature but at the temperature of the source of the other radiating surface or
emitter, since this is the temperature the absorbing surface would reach if the absorber and emitter were
at thermal equilibrium. The temperature of the absorber has only a slight effect on the absorptivity.

4 .11B. De r iv ation of Vie w  Factor s in R ad iation for  Var iou s G e om e tr ie s

1. Int r od u ct ion

The concepts and definitions presented in Section 4.11A form a sufficient foundation so that the net
radiant exchange between surfaces can be determined. If two surfaces are arranged so that radiant energy
can be exchanged, a net flow of energy will occur from the hotter surface to the colder surface. The size,
shape, and orientation of two radiating surfaces or a system of surfaces are factors in determining the net
heat-flow rate between them. To simplify the discussion we assume that the surfaces are separated by a
nonabsorbing medium such as air. This assumption is adequate for many engineering applications.
However, in cases such as a furnace, the presence of CO2 and H2O vapor make such a simplification
impossible because of their high absorptivities.

The simplest geometrical configuration will be considered first, that of radiation exchange between
parallel, infinite planes. This assumption implies that there are no edge effects in the case of finite
surfaces. First, the simplest case will be treated, in which the surfaces are black bodies, and then more
complicated geometries and gray bodies will be treated.

2. View  fa ct or  for  infinit e p a r a llel b la ck  p la nes

If two parallel and infinite black planes at T1 and T2 are radiating toward each other, plane 1 emits 

radiation to plane 2, which is all absorbed. Also, plane 2 emits   radiation to plane 1, which is all
absorbed. Then for plane 1, the net radiation is from plane 1 to 2,

Equation 4.11-13

In this case all the radiation from 1 to 2 is intercepted by 2; that is, the fraction of radiation leaving 1 that
is intercepted by 2 is F 12, which is 1.0. The factor F 12 is called the geometric view factor or simply view
factor. Hence,

Equation 4.11-14

where F12 is fraction of radiation leaving surface 1 in all directions which is intercepted by surface 2. Also,

Equation 4.11-15
In the case of parallel plates, F12 = F21 = 1.0 and the geometric factor is simply omitted.

3. View  fa ct or  for  infinit e p a r a llel g r a y  p la nes

If both of the parallel plates A 1 and A 2 are gray, with emissivities and absorptivities of ε1 = α1 and ε2 =


α2, respectively, we can proceed as follows. Since each surface has an unobstructed view of the other, the

view factor is 1.0. In unit time, surface A1 emits   radiation to A2. Of this, the fraction ε2 (where
α2 = ε2) is absorbed:

Equation 4.11-16

Also, the fraction (1 - ε2) or the amount (1 - ε2)( ) is reflected back to A1. Of this amount A1

reflects back to A2 a fraction (1 - ε1) or an amount (1 - ε1)(1 - ε2)( ). The surface A2 absorbs the
fraction ε2, or

Equation 4.11-17

The amount reflected back to A1 from A2 is (1 - ε2)(1 - ε1)(1 - ε2)( ). Then A1 absorbs ε1 of this

and reflects back to A2 an amount (1 - ε1)(1 - ε2)(1 - ε1)(1 - ε2) × ( ). The surface A2 then absorbs

Equation 4.11-18

This continues, and the total amount absorbed at A2 is the sum of Eqs. (4.11-16), (4.11-17), (4.11-18),
and so on:

Equation 4.11-19
The result is a geometric series (M1):

Equation 4.11-20

Repeating the above for the amount absorbed at A1 which comes from A2,

Equation 4.11-21

The net radiation is the difference of Eqs. (4.11-20) and (4.11-21):

Equation 4.11-22

If ε1 = ε2 = 1.0 for black bodies, Eq. (4.11-22) becomes Eq. (4.11-13).

EXAMPLE 4.11-1. Radiation Between Parallel Planes
Two parallel gray planes which are very large have emissivities of ε1 = 0.8 and ε2 = 0.7; surface
1 is at 1100°F (866.5 K) and surface 2 at 600°F (588.8 K). Use English and SI units for the
following:

a.  What is the net radiation from 1 to 2?

b.  If the surfaces are both black, what is the net radiation?

S olu t ion: For part (a), using Eq. (4.11-22) and substituting the known values,

For black surfaces in part (b), using Eq. (4.11-13),
Note the large reduction in radiation when surfaces with emissivities less than 1.0 are used.

Example 4.11-1 shows the large influence that emissivities less than 1.0 have on radiation. This fact is
used to reduce radiation loss or gain from a surface by using planes as a radiation shield. For example,
for two parallel surfaces of emissivity ε at T1 and T2, the interchange is, by Eq. (4.11-22),

Equation 4.11-23

The subscript 0 indicates that there are no planes in between the two surfaces. Suppose that we now
insert one or more radiation planes between the original surfaces. Then it can be shown that

Equation 4.11-24

where N is the number of radiation planes or shields between the original surfaces. Hence, a great
reduction in radiation heat loss is obtained by using these shields.

4 . Der iv a t ion of g ener a l eq u a t ion for  v iew  fa ct or  b et w een b la ck  b od ies

Suppose that we consider radiation between two parallel black planes of finite size as shown in Fig. 4.11-
2a. Since the planes are not infinite in size, some of the radiation from surface 1 does not strike surface 2,
and vice versa. Hence, the net radiation interchange is less, since some is lost to the surroundings. The
fraction of radiation leaving surface 1 in all directions which is intercepted by surface 2 is called F12 and
must be determined for each geometry by taking differential surface elements and integrating over the
entire surface.

Figure 4.11-2. Radiation between two black surfaces: (a) two planes alone, (b) two planes connected by
refractory reradiating walls.
Before we can derive a general relationship for the view factor between two finite bodies, we must consider
and discuss two quantities, a solid angle and the intensity of radiation. A solid angle ω is a
dimensionless quantity which is a measure of an angle in solid geometry. In Fig. 4.11-3a the differential
solid angle dω 1 is equal to the normal projection of dA2 divided by the square of the distance between the
point P and area dA2:

Equation 4.11-25

Figure 4.11-3. Geometry for a solid angle and intensity of radiation: (a) solid-angle geometry, (b) intensity of
radiation from emitting area dA.

The units of a solid angle are steradian or sr. For a hemisphere the number of sr subtended by this surface
is 2π.

The intensity of radiation for a black body, IB, is the rate of radiation emitted per unit area projected in a
direction normal to the surface and per unit solid angle in a specified direction as shown in Fig. 4.11-3b.
The projection of dA on the line between centers is dA cos θ.

Equation 4.11-26

where q is in W and IB is in W/m2 · sr. We assume that the black body is a diffuse surface which emits
with equal intensity in all directions, that is, I = constant. The emissive power EB which leaves a black-
body plane surface is determined by integrating Eq. (4.11-26) over all solid angles subtended by a
hemisphere covering the surface. The final result is as follows [see references (C3, H1, K1) for details]:

Equation 4.11-27

where EB is in W/m2.

In order to determine the radiation heat-transfer rates between two black surfaces, we must determine
the general case for the fraction of the total radiant heat that leaves a surface and arrives on a second
surface. Using only black surfaces, we consider the case shown in Fig. 4.11-4, in which radiant energy is
exchanged between area elements dA1 and dA2. The line r is the distance between the areas, and the
angles between this line and the normals to the two surfaces are θ1 and θ2. The rate of radiant energy that
leaves dA1 in the direction given by the angle θ1 is IB1 dA cos θ1. The rate that leaves dA1 and arrives on
dA2 is given by Eq. (4.11-28):

Equation 4.11-28

Figure 4.11-4. Area elements for radiation shape factor.
where dω 1 is the solid angle subtended by the area dA2 as seen from dA1. Combining Eqs. (4.11-25) and
(4.11-28),

Equation 4.11-29

From Eq. (4.11-27), IB1 = EB1 /π. Substituting EB1 /π for IB1 into Eq. (4.11-29),

Equation 4.11-30

The energy leaving dA2 and arriving at dA1 is

Equation 4.11-31

Substituting   for EB1 and   for EB2 from Eq. (4.11-4) and taking the difference of Eqs. (4.11-30)


and (4.11-31) for the net heat flow,

Equation 4.11-32

Performing the double integrations over surfaces A1 and A2 will yield the total net heat flow between the
finite areas:

Equation 4.11-33

Equation (4.11-33) can also be written as

Equation 4.11-34
where F12 is a geometric shape factor or view factor and designates the fraction of the total radiation
leaving A1 which strikes A2, and F21 represents the fraction leaving A2 which strikes A1. Also, the
following relation exists:

Equation 4.11-35

which is valid for black surfaces and nonblack surfaces. The view factor F12 is then

Equation 4.11-36

Values of the view factor can be calculated for a number of geometrical arrangements.

5. View  fa ct or s b et w een b la ck  b od ies for  v a r iou s g eomet r ies

A number of basic relationships between view factors are given below.

The reciprocity relationship given by Eq. (4.11-35) is

Equation 4.11-35

This relationship can be applied to any two surfaces i and j:

Equation 4.11-37

If surface A1 can only see surface A2, then F12 = 1.0.

If surface A1 sees a number of surfaces A2,A3, . . ., and all the surfaces form an enclosure, then the
enclosure relationship is

Equation 4.11-38
If the surface A1 cannot see itself (surface is flat or convex), F11 = 0.

EXAMPLE 4.11-2. View Factor from a Plane to a
Hemisphere
Determine the view factors between a plane A1 covered by a hemisphere A2 as shown in Fig.
4.11-5.

Figure 4.11-5. Radiant exchange between a flat surface and a hemisphere for Example 4.11-2.

S olu t ion: Since surface A1 sees only A2, the view factor F12 = 1.0. Using Eq. (4.11-35),

Equation 4.11-35

The area A1 = πR2;A2 = 2πR2. Substituting into Eq. (4.11-35) and solving for F21,

Using Eq. (4.11-38) for surface A1, F11 = 1.0 - F12 = 1.0 - 1.0 = 0. Also, writing Eq. (4.11-38) for
surface A2,

Equation 4.11-39

Solving for F22, F22 = 1.0 - F21 = 1.0 -   =  .

EXAMPLE 4.11-3. Radiation Between Parallel Disks
In Fig. 4.11-6 a small disk of area A1 is parallel to a large disk of area A2, with A1 centered
directly below A2. The distance between the centers of the disks is R and the radius of A2 is a.
Determine the view factor for radiant heat transfer from A1 to A2.

Figure 4.11-6. View factor for radiation from a small element to a parallel disk for Example 4.11-3.

S olu t ion: The differential area for A2 is taken as the circular ring of radius x so that dA2 = 2πx
dx. The angle θ1 = θ2. Using Eq. (4.11-36),

In this case the area A1 is very small compared to A2, so dA1 can be integrated to A1 and the

other terms inside the integral can be assumed constant. From the geometry shown, r = (R2 +
x2)1/2, cos θ1 = R/(R2 + x2)1/2. Making these substitutions into the equation for F12,

Integrating,

The integration of Eq. (4.11-36) has been performed for numerous geometrical configurations
and values of F12 tabulated. Then,

Equation 4.11-34
where F12 is the fraction of the radiation leaving A1 which is intercepted by A2 and F21 the
fraction reaching A1 from A2. Since the flux from 1 to 2 must equal that from 2 to 1, Eq. (4.11-
34) becomes Eq. (4.11-35) as given previously:

Equation 4.11-35

Hence, one selects the surface whose view factor can be determined most easily. For example,
the view factor F12 for a small surface A1 completely enclosed by a large surface A2 is 1.0, since
all the radiation leaving A1 is intercepted by A2. In Fig. 4.11-7 the view factors F12 between
parallel planes are given, and in Fig. 4.11-8 the view factors for adjacent perpendicular
rectangles. View factors for other geometries are given elsewhere (H1, K1, P3, W1).

Figure 4.11-7. View factor between parallel planes directly opposed. (From W. H. McAdams, Heat
Transmission, 3rd ed. New York McGraw-Hill Book Company, 1954. With permission.)

Figure 4.11-8. View factor for adjacent perpendicular rectangles. [From H. C. Hottel, Mech. Eng., 
52, 699 (1930). With permission.]
4 .11C . Vie w  Factor s W he n S u r face s Ar e  C onne cte d  b y R e r ad iating W alls

If the two black-body surfaces A1 and A2 are connected by nonconducting (refractory) but reradiating
walls as in Fig. 4.11-2b, a larger fraction of the radiation from surface 1 is intercepted by 2. This view

factor is called  . The case of two surfaces connected by the walls of an enclosure such as a furnace is a
common example of this. The general equation for this case assuming a uniform refractory temperature
has been derived (M1, C3) for two radiant sources A1 and A2 which are not concave, so they do not see
themselves:

Equation 4.11-40

Also, as before,

Equation 4.11-41

Equation 4.11-42
The factor   for parallel planes is given in Fig. 4.11-7 and for other geometries can be calculated from

Eq. (4.11-36). For view factors F12 and   for parallel tubes adjacent to a wall as in a furnace as well as
for variation in refractory wall temperature, see elsewhere (M1, P3). If there are no reradiating walls,

Equation 4.11-43

4 .11D. Vie w  Factor s and  G r ay Bod ie s

A general and more practical case, which is the same as for Eq. (4.11-40) but with the surfaces A1 and A2
being gray with emissivities ε1 and ε2, will be considered. Nonconducting reradiating walls are present as
before. Since the two surfaces are now gray, there will be some reflection of radiation, which will decrease
the net radiant exchange between the surfaces below that for black surfaces. The final equations for this
case are

Equation 4.11-44

Equation 4.11-45

where   is the new view factor for two gray surfaces A1 and A2 which cannot see themselves and are

connected by reradiating walls. If no refractory walls are present, F12 is used in place of   in Eq. (4.11-
41). Again,

Equation 4.11-46

EXAMPLE 4.11-4. Radiation Between Infinite Parallel Gray
Planes
Derive Eq. (4.11-22) by starting with the general equation for radiation between two gray
bodies A1 and A2 which are infinite parallel planes having emissivities ε1 and ε2, respectively.

S olu t ion: Since there are no reradiating walls, by Eq. (4.11-43)   becomes F12. Also, since


all the radiation from surface 1 is intercepted by surface 2, F12 = 1.0. Substituting into Eq.
(4.11-45), noting that A1/A2 = 1.0,

Then using Eq. (4.11-44),

This is identical to Eq. (4.11-22).

EXAMPLE 4.11-5. Complex View Factor for Perpendicular
Rectangles
Find the view factor F12 for the configuration shown in Fig. 4.11-9 of the rectangle with area A2
displaced from the common edge of rectangle A1 and perpendicular to A1. The temperature of
A1 is T1 and that of A2 and A3 is T2.

Figure 4.11-9. Configuration for Example 4.11-5.
S olu t ion: The area A3 is a fictitious area between areas A2 and A1. Designate the area A2 plus
A3 as A(23). The view factor F1(23) for areas A1 and A(23) can be obtained from Fig. 4.11-8 for
adjacent perpendicular rectangles. Also, F13 can be obtained from Fig. 4.11-8. The radiation
interchange between A1 and A(23) is equal to that intercepted by A2 and by A3:

Equation 4.11-47

Hence,

Equation 4.11-48

Solving for F12,

Equation 4.11-49

Methods similar to those used in this example can be employed to find the shape factors for a general
orientation of two rectangles in perpendicular planes or parallel rectangles (C3, H1, K1).

EXAMPLE 4.11-6. Radiation to a Small Package
A small, cold package having an area A1 and emissivity ε1 is at temperature T1. It is placed in a
warm room with the walls at T2 and an emissivity ε2. Using Eq. (4.11-45), derive the view
factor for this and the equation for the radiation heat transfer.
S olu t ion: For the small surface A1 completely enclosed by the enclosure A2,   = F12 by Eq.
(4.11-43), since there are no reradiating (refractory) walls. Also, F12 = 1.0, since all the
radiation from A1 is intercepted by the enclosure A2 because A1 does not have any concave
surfaces and cannot "see" itself. Since A2 is very large compared to A1, A1/A2 = 0. Substituting
into Eq. (4.11-45),

Substituting into Eq. (4.11-44),

This is the same as Eq. (4.10-6) derived previously.

For solving complicated radiation problems involving more than four or five heat-transfer surfaces,
matrix methods have been developed and are discussed in detail elsewhere (H1, K1).

4 .11E. R ad iation in Ab sor b ing G ase s

1. Int r od u ct ion t o a b sor b ing  g a ses in r a d ia t ion

As discussed in this section, solids and liquids emit radiation over a continuous spectrum. However,
most gases that are monatomic or diatomic, such as He, Ar, H2, O2, and N2, are virtually transparent to
thermal radiation; that is, they emit practically no radiation and do not absorb radiation. Gases with a
dipole moment and higher polyatomic gases emit significant amounts of radiation and also absorb
radiant energy within the same bands in which they emit radiation. These gases include CO2, H2O, CO,
SO2, NH3, and organic vapors.

For a particular gas, the width of the absorption or emission bands depends on the pressure and also the
temperature. If an absorbing gas is heated, it radiates energy to the cooler surroundings. The net
radiation heat-transfer rate between surfaces is decreased in these cases because the gas absorbs some of
the radiant energy being transported between the surfaces.

2. Ab sor p t ion of r a d ia t ion b y  a  g a s

The absorption of radiation in a gas layer can be described analytically, since the absorption by a given
gas depends on the number of molecules in the path of radiation. Increasing the partial pressure of the
absorbing gas or the path length increases the amount of absorption. We define IλO as the intensity of
radiation at a particular wavelength before it enters the gas and IλL as the intensity at the same
wavelength after having traveled a distance of L in the gas. If the beam impinges on a gas layer of
thickness dL, the decrease in intensity, dIλ, is proportional to Iλ and dL:
Equation 4.11-50

where Iλ is in W/m2. Integrating,

Equation 4.11-51

The constant αλ depends on the particular gas, its partial pressure, and the wavelength of radiation. This
equation is called Beer's law. Gases frequently absorb only in narrow-wavelength bands.

3. C ha r a ct er ist ic mea n b ea m leng t h of a b sor b ing  g a s

The calculation methods for gas radiation are quite complicated. For the purpose of engineering
calculations, Hottel (M1) has presented approximate methods for calculating radiation and absorption
when gases such as CO2 and water vapor are present. Thick layers of a gas absorb more energy than do
thin layers. Hence, in addition to specifying the pressure and temperature of a gas, we must specify a
characteristic length (mean beam length) of a gas mass to determine the emissivity and absorptivity of a
gas. The mean beam length L depends on the specific geometry.

For a black differential receiving surface area dA located in the center of the base of a hemisphere of radius
L containing a radiating gas, the mean beam length is L. The mean beam length has been evaluated for
various geometries, as presented in Table 4.11-1. For other shapes, L can be approximated by

Equation 4.11-52

Table 4.11-1. Mean Beam Length for Gas Radiation to Entire Enclosure Surface (M1, R2, P3)

Geometry of Enclosure Mean Beam Length, L

Sphere, diameter D 0.65D
Infinite cylinder, diameter D 0.95D

Cylinder, length = diameter D 0.60D

Infinite parallel plates, separation distance D 1.8D
Hemisphere, radiation to element in base, radius R R

Cube, radiation to any face, side D 0.60D
Volume surrounding bank of long tubes with centers on
equilateral triangle, clearance = tube diameter D 2.8D
where V is volume of the gas in m3, A is surface area of the enclosure in m2, and L is in m.

4 . Emissiv it y , a b sor p t iv it y , a nd  r a d ia t ion of a  g a s

Gas emissivities have been correlated and Fig. 4.11-10 gives the gas emissivity εG of CO2 at a total
pressure of the system of 1.0 atm abs. The pG is the partial pressure of CO2 in atm and L is the mean
beam length in m. The emissivity εG is defined as the ratio of the rate of energy transfer from the
hemispherical body of gas to a surface element at the midpoint divided by the rate of energy transfer from
a black hemisphere surface of radius L and temperature TG to the same element.

Figure 4.11-10. Total emissivity of the gas carbon dioxide at a total pressure of 1.0 atm. (From W. H.
McAdams, Heat Transmission, 3rd ed. New York: McGraw-Hill Book Company, 1954. With permission.)

The rate of radiation emitted from the gas is   in W/m2 of receiving surface element, where εG is
evaluated at TG. If the surface element at the midpoint at T1 is radiating heat back to the gas, the

absorption rate of the gas will be  , where αG is the absorptivity of the gas for black-body
radiation from the surface at T1. The αG of CO2 is determined from Fig. 4.11-10 at T1, but instead of the
parameter pGL, the parameter pG L(T1/TG) is used. The resulting value from the chart is then multiplied

by (TG/T1)0.65 to give αG. The net rate of radiant transfer between a gas at TG and a black surface of finite
area A1 at T1 is then

Equation 4.11-53

When the total pressure is not 1.0 atm, a correction chart is available to correct the emissivity of CO2.
Charts are also available for water vapor (H1, K1, M1, P3). When both CO2 and H2O are present the total
radiation is reduced somewhat, since each gas is somewhat opaque to radiation from the other gas.
Charts for these interactions are also available (H1, K1, M1, P3).

EXAMPLE 4.11-7. Gas Radiation to a Furnace Enclosure
A furnace is in the form of a cube 0.3 m on a side inside, and these interior walls can be
approximated as black surfaces. The gas inside at 1.0 atm total pressure and 1100 K contains
10 mol % CO2 and the rest is O2 and N2. The small amount of water vapor present will be
neglected. The walls of the furnace are maintained at 600 K by external cooling. Calculate the
total heat transfer to the walls neglecting heat transfer by convection.

S olu t ion: From Table 4.11-1, the mean beam length for radiation to a cube face is L = 0.60D =
0.60(0.30) = 0.180 m. The partial pressure of CO2 is pG = 0.10(100) = 0.10 atm. Then pGL =
0.10(0.180) = 0.0180 atm m. From Fig. 4.11-10, εG = 0.064 at TG = 1100 K.

To obtain αG, we evaluate αG at T1 = 600 K and pGL(T1/TG) = (0.0180) (600/1100) = 0.00982
atm · m. From Fig. 4.11-10, the uncorrected value of αG = 0.048. Multiplying this by the

correction factor (TG/T1)0.65, the final correction value is

Substituting into Eq. (4.11-53),

For six sides, A = 6(0.3 × 0.3) = 0.540 m2. Then,

For the case where the walls of the enclosure are not black, some of the radiation striking the walls is
reflected back to the other walls and into the gas. As an approximation when the emissivity of the walls is
greater than 0.7, an effective emissivity ε' can be used:

Equation 4.11-54

where ε is the actual emissivity of the enclosure walls. Then Eq. (4.11-53) is modified to give the following
(M1):

Equation 4.11-55

Other approximate methods are available for gases containing suspended luminous flames, clouds of
nonblack particles, refractory walls and absorbing gases present, and so on (M1, P3).
                             
                                                 
                                             
                                               
     

4.12. HEAT TRANSFER OF NON­NEWTONIAN FLUIDS

4 .12A. Intr od u ction

Most of the studies on heat transfer with fluids have been done with Newtonian fluids. However, a wide
variety of non-Newtonian fluids are encountered in the industrial chemical, biological, and food
processing industries. To design equipment to handle these fluids, the flow-property constants
(rheological constants) must be available or must be measured experimentally. Section 3.5 gave a
detailed discussion of rheological constants for non-Newtonian fluids. Since many non-Newtonian fluids
have high effective viscosities, they are often in laminar flow. Since the majority of non-Newtonian fluids
are pseudoplastic fluids, which can usually be represented by the power law, Eq. (3.5-2), the discussion
will be concerned with such fluids. For other fluids, the reader is referred to Skelland (S3).

4 .12B. He at Tr ansfe r  Insid e  Tu b e s

1. La mina r  flow  in t u b es

A large portion of the experimental investigations have been concerned with heat transfer of non-
Newtonian fluids in laminar flow through cylindrical tubes. The physical properties that are needed for
heat-transfer coefficients are density, heat capacity, thermal conductivity, and the rheological constants
K' and n' or K and n.

In heat transfer in a fluid in laminar flow, the mechanism is primarily one of conduction. However, for
low flow rates and low viscosities, natural convection effects can be present. Since many non-Newtonian
fluids are quite "viscous," natural convection effects are reduced substantially. For laminar flow inside
circular tubes of power-law fluids, the equation of Metzner and Gluck (M2) can be used with highly
"viscous" non-Newtonian fluids with negligible natural convection for horizontal or vertical tubes for the
Graetz number NGz > 20 and n' > 0.10:

Equation 4.12-1

where

Equation 4.12-2
Equation 4.12-3

The viscosity coefficients γb at temperature Tb and γw  at Tw  are defined as

Equation 4.12-4

The nomenclature is as follows: k in W/m · K, cp in J/kg · K, ρ in kg/m3, flow rate m in kg/s, length of

heated section of tube L in m, inside diameter D in m, the mean coefficient ha  in W/m2 · K, and K and n'
rheological constants (see Section 3.5). The physical properties and Kb are all evaluated at the mean bulk
temperature Tb and Kw  at the average wall temperature Tw .

The value of the rheological constant n' or n has been found not to vary appreciably over wide
temperature ranges (S3). However, the rheological constant K' or K has been found to vary appreciably. A
plot of log K' versus 1/Tabs (C1) or versus T°C (S3) can often be approximated by a straight line. Often
data for the temperature effect on K are not available. Since the ratio Kb/Kw  is taken to the 0.14 power,
this factor can sometimes be neglected without causing large errors. For a value of the ratio of 2:1, the
error is only about 10%. A plot of log viscosity versus 1/T for Newtonian fluids is also often a straight line.
The value of ha  obtained from Eq. (4.12-1) is the mean value to use over the tube length L with the
arithmetic temperature difference ΔTa :

Equation 4.12-5

when Tw  is the average wall temperature for the whole tube and Tbi is the inlet bulk temperature and Tbo
the outlet bulk temperature. The heat flux q is

Equation 4.12-6

EXAMPLE 4.12-1. Heating a Non-Newtonian Fluid in
Laminar Flow
A non-Newtonian fluid flowing at a rate of 7.56 × 10-2 kg/s inside a 25.4-mm-ID tube is being
heated by steam condensing outside the tube. The fluid enters the heating section of the tube,
which is 1.524 m long, at a temperature of 37.8°C. The inside wall temperature Tw  is constant

at 93.3°C. The mean physical properties of the fluid are ρ = 1041 kg/m3, cpm = 2.093 kJ/kg · K,
and k = 1.212 W/m · K. The fluid is a power-law fluid having the following flow-property
(rheological) constants: n = n' = 0.40, which is approximately constant over the temperature
range encountered, and K = 139.9 N · sn'/m2 at 37.8°C and 62.5 at 93.3°C. For this fluid a plot
of log K versus T°C is approximately a straight line. Calculate the outlet bulk temperature of
the fluid if it is in laminar flow.

S olu t ion: The solution is trial and error, since the outlet bulk temperature Tbo of the fluid
must be known in order to calculate ha  from Eq. (4.12-2). Assuming Tbo = 54.4°C for the first
trial, the mean bulk temperature Tb is (54.4 + 37.8)/2, or 46.1°C.

Plotting the two values of K given at 37.8 and 93.3°C as log K versus T°C and drawing a
straight line through these two points, a value for Kb of 123.5 at Tb = 46.1°C is read from the
plot. At Tw  = 93.3°C, Kw  = 62.5.

Next, δ is calculated using Eq. (4.12-2):

Substituting into Eq. (4.12-3),

From Eq. (4.12-4),

Then substituting into Eq. (4.12-1),

Equation 4.12-1
Solving, ha  = 448.3 W/m2 · K.

By a heat balance, the value of q in W is as follows:

Equation 4.12-7

This is equated to Eq. (4.12-6) to obtain

Equation 4.12-8

The arithmetic mean temperature difference ΔTa  by Eq. (4.12-5) is

Substituting the known values in Eq. (4.12-8) and solving for Tbo,

This value of 54.1°C is close enough to the assumed value of 54.5°C that a second trial is not
needed. Only the value of Kb would be affected. Known values can be substituted into Eq. (3.5-
11) for the Reynolds number to show that it is less than 2100 and that the flow is laminar.

For less "viscous" non-Newtonian power-law fluids in laminar flow, natural convection may affect the
heat-transfer rates. Metzner and Gluck (M2) recommend use of an empirical correction to Eq. (4.12-1) for
horizontal tubes.

2. Tu r b u lent  flow  in t u b es

For turbulent flow of power-law fluids through tubes. Clapp (C4) presents the following empirical
equation for heat transfer:

Equation 4.12-9
where NRe,gen  is defined by Eq. (3.5-11) and hL is the heat-transfer coefficient based on the log mean
temperature driving force. The fluid properties are evaluated at the bulk mean temperature. Metzner and
Friend (M3) also give equations for turbulent heat transfer.

4 .12C . Natu r al C onv e ction

Acrivos (A1, S3) gives relationships for natural convection heat transfer to power-law fluids from various
geometries of surfaces such as spheres, cylinders, and plates.
                             
                                                 
                                             
                                               
     

4.13. SPECIAL HEAT­TRANSFER COEFFICIENTS

4 .13A. He at Tr ansfe r  in Agitate d  Ve sse ls

1. Int r od u ct ion

Many chemical and biological processes are often carried out in agitated vessels. As discussed in Section
3.4, the liquids are generally agitated in cylindrical vessels with an impeller mounted on a shaft and
driven by an electric motor. Typical agitators and vessel assemblies have been shown in Figs. 3.4-1 and
3.4-3. Often it is necessary to cool or heat the contents of the vessel during agitation. This is usually done
by heat-transfer surfaces, which may be in the form of cooling or heating jackets in the wall of the vessel
or coils of pipe immersed in the liquid.

2. Vessel w it h he a t ing  ja ck e

In Fig. 4.13-1a, a vessel with a cooling or heating jacket is shown. When heating, the fluid entering is
often steam, which condenses inside the jacket and leaves at the bottom. The vessel is equipped with an
agitator and in most cases also with baffles (not shown).

Figure 4.13-1. Heat tr ansfer in agitated vessels: (a) vessel with heating jacket, (b) vessel with heating coils.

Correlations for the heat-transfer coefficient from the agitated Newtonian liquid inside the vessel to the
jacket walls of the vessel have the following form:

Equation 4.13-1
where h is the heat-transfer coefficient for the agitated liquid to the inner wall in W/m2 · K, Dt is the
inside diameter of the tank in m, k is thermal conductivity in W/m · K, Da  is diameter of agitator in m, N

is rotational speed in revolutions per sec, ρ is fluid density in kg/m3, and μ, is liquid viscosity in Pa · s.
All the liquid physical properties are evaluated at the bulk liquid temperature except μw , which is
evaluated at the wall temperature Tw . Below are listed some available correlations and the Reynolds-

number range ( ).

1.  Paddle agitator with no baffles (C5, U1)

2.  Flat-blade turbine agitator with no baffles (B4)

3.  Flat-blade turbine agitator with baffles (B4, B5)

4.  Anchor agitator with no baffles (U1)

5.  Helical-ribbon agitator with no baffles (G4)

Some typical overall U values for jacketed vessels for various process applications are tabulated in Table
4.13-1.
Table 4.13-1. Typical Overall Heat-Transfer Coefficients in Jacketed Vessels

btu W
Fluid in
Jacket Fluid in Vessel Wall Material Agitation h · ft 2  · °F m 2  · K Ref.

Steam Water Copper None 150 852 (P1)

Simple stirring 250 1420  

Steam Paste Cast iron Double scrapers 125 710 (P1)


Steam Boiling water Copper None 250 1420 (P1)

Steam Milk Enameled cast None 200 1135 (P1)


iron
Stirring 300 1700  
Hot water Cold water Enameled cast None 70 398 (P1)
iron

Steam Tomato purée Metal Agitation 30 170 (C1)

EXAMPLE 4.13-1. Heat-Transfer Coefficient in Agitated
Vessel with Jacket
A jacketed 1.83-m-diameter agitated vessel with baffles is being used to heat a liquid which is
at 300 K. The agitator is 0.61 m in diameter and is a flat-blade turbine rotating at 100 rpm.
Hot water is in the heating jacket. The wall surface temperature is constant at 355.4 K. The
liquid has the following bulk physical properties: ρ = 961 kg/m3, cp = 2500 J/kg · K, k = 0.173
W/m · K, and μ = 1.00 Pa · s at 300 K and 0.084 Pa · s at 355.4 K. Calculate the heat-transfer
coefficient to the wall of the jacket.

S olu t ion: The following are given:

First, calculating the Reynolds number at 300 K,

The Prandtl number is
Using Eq. (4.13-1) with a = 0.74, b =  , and m = 0.14,

Equation 4.13-1

Substituting and solving for h,

A correlation to predict the heat-transfer coefficient of a power-law non-Newtonian fluid in a jacketed
vessel with a turbine agitator is also available elsewhere (C6).

3. Vessel w it h hea t ing  coils

In Fig. 4.13-1b, an agitated vessel with a helical heating or cooling coil is shown. Correlations for the
heat-transfer coefficient to the outside surface of the coils in agitated vessels are listed below for various
types of agitators.

For a paddle agitator with no baffles (C5),

Equation 4.13-2

This holds for a Reynolds-number range of 300 to 4 × 105.

For a flat-blade turbine agitator with baffles, see (O1).

When the heating or cooling coil is in the form of vertical tube baffles with a flat-blade turbine, the
following correlation can be used (D1):

Equation 4.13-3
where D0 is the outside diameter of the coil tube in m, nb is the number of vertical baffle tubes, and μf is
the viscosity at the mean film temperature.

Perry and Green (P3) give typical values of overall heat-transfer coefficients U for coils immersed in
various liquids in agitated and nonagitated vessels.

4 .13B. S cr ap e d -S u r face  He at Exchange r s

Liquid-solid suspensions, viscous aqueous and organic solutions, and numerous food products, such as
margarine and orange juice concentrate, are often cooled or heated in a scraped-surface exchanger. This
consists of a double-pipe heat exchanger with a jacketed cylinder containing steam or cooling liquid and
an internal shaft rotating and fitted with wiper blades, as shown in Fig. 4.13-2.

Figure 4.13-2. Scraped-surface heat exchanger.

The viscous liquid product flows at low velocity through the central tube between the rotating shaft and
the inner pipe. The rotating scrapers or wiper blades continually scrape the surface of liquid, preventing
localized overheating and giving rapid heat transfer. In some cases this device is also called a votator
heat exchanger.

Skelland et al. (S4) give the following equation to predict the inside heat-transfer coefficient for the
votator:

Equation 4.13-4
where D = diameter of vessel in m, DS = diameter of rotating shaft in m, v = axial flow velocity of liquid in
m/s, N = agitator speed in rev/s, and nB = number of blades on agitator. Data cover a region of axial flow
velocities of 0.076 to 0.38 m/min and rotational speeds of 100 to 750 rpm.

Typical overall heat-transfer coefficients in food applications are U = 1700 W/m2 · K (300 btu/h · ft 2 · F)
for cooling margarine with NH3, 2270 (400) for heating applesauce with steam, 1420 (250) for chilling
shortening with NH3, and 2270 (400) for cooling cream with water (B6).

4 .13C . Exte nd e d  S u r face  or  Finne d  Exchange r s

1. Int r od u ct ion

The use of fins or extended surfaces on the outside of a heat-exchanger pipe wall to give relatively high
heat-transfer coefficients in the exchanger is quite common. An automobile radiator is such a device,
where hot water passes inside through a bank of tubes and loses heat to the air. On the outside of the
tubes, extended surfaces receive heat from the tube walls and transmit it to the air by forced convection.

Two common types of fins attached to the outside of a tube wall are shown in Fig. 4.13-3. In Fig. 4.13-3a
there are a number of longitudinal fins spaced around the tube wall and the direction of gas flow is
parallel to the axis of the tube. In Fig. 4.13-3b the gas flows normal to the tubes containing many circular
or transverse fins.

Figure 4.13-3. Two common types of fins on a section of circular tube: (a) longitudinal fin, (b) circular or
transverse fin.

The qualitative effect of using extended surfaces can be shown approximately in Eq. (4.13-5) for a fluid
inside a tube having a heat-transfer coefficient of hi and an outside coefficient of h0:

Equation 4.13-5
The resistance Rmetal of the wall can often be neglected. The presence of the fins on the outside increases
A0 and hence reduces the resistance 1/h0A0 of the fluid on the outside of the tube. For example, if we
have hi for condensing steam, which is very large, and h0 for air outside the tube, which is quite small,
increasing A0 greatly reduces 1/h0A0. This in turn greatly reduces the total resistance, which increases
the heat-transfer rate. If the positions of the two fluids are reversed, with air inside and steam outside,
little increase in heat transfer could be obtained by using fins.

Equation (4.13-5) is only an approximation, since the temperature on the outside surface of the bare tube
is not the same as that at the end of the fin because of the added resistance to heat flow by conduction
from the fin tip to the base of the fin. Hence, a unit area of fin surface is not as efficient as a unit area of
bare tube surface at the base of the fin. A fin efficiency ηf has been mathematically derived for various
geometries of fins.

2. Der iv a t ion of eq u a t ion for  fin efficiency

We will consider a one-dimensional fin exposed to a surrounding fluid at temperature T∞ as shown in
Fig. 4.13-4. At the base of the fin the temperature is T0 and at point x it is T. At steady state, the rate of
heat conducted into the element at x is qx|x and is equal to the rate of heat conducted out plus the rate of
heat lost by convection:

Equation 4.13-6

Figure 4.13-4. Heat balance for one-dimensional conduction and convection in a rectangular fin with constant
cross-sectional area.

Substituting Fourier's equation for conduction and the convection equation,
Equation 4.13-7

where A is the cross-sectional area of the fin in m2, P the perimeter of the fin in m, and (P Δx) the area for
convection. Rearranging Eq. (4.13-7), dividing by Δx, and letting Δx approach zero,

Equation 4.13-8

Letting θ = T - T∞, Eq. (4.13-8) becomes

Equation 4.13-9

The first boundary condition is that θ = θ0 = T0 − T∞ at x = 0. For the second boundary condition needed
to integrate Eq. (4.13-9), several cases can be considered, depending upon the physical conditions at x =
L. In the first case, the end of the fin is insulated and dθ/dx = 0 at x = L. In the second case, the fin loses
heat by convection from the tip surface, so that -k(dT/dx)L = h(TL − T∞). The solution using the second
case is quite involved and will not be considered here. Using the first case, where the tip is insulated,
integration of Eq. (4.13-9) gives

Equation 4.13-10

where m = (hP/kA)1/2.

The heat lost by the fin is expressed as

Equation 4.13-11

Differentiating Eq. (4.13-10) with respect to x and combining it with Eq. (4.13-11),

Equation 4.13-12
In the actual fin the temperature T in the fin decreases as the tip of the fin is approached. Hence, the rate
of heat transfer per unit area decreases as the distance from the tube base is increased. To indicate this
effectiveness of the fin in transferring heat, the fin efficiency ηf is defined as the ratio of the actual heat
transferred from the fin to the heat transferred if the entire fin were at the base temperature T0:

Equation 4.13-13

where PL is the entire surface area of fin. The expression for mL is

Equation 4.13-14

For fins which are thin, 2t is small compared to 2w, and

Equation 4.13-15

Equation (4.13-15) holds for a fin with an insulated tip. This equation can be modified to hold for the
case where the fin loses heat from its tip. This can be done by extending the length of the fin by t/2, where
the corrected length Lc to use in Eqs. (4.13-13)–(4.13-15) is

Equation 4.13-16

The fin efficiency calculated from Eq. (4.13-13) for a longitudinal fin is shown in Fig. 4.13-5a. In Fig.
4.13-5b, the fin efficiency for a circular fin is presented. Note that the abscissa on the curves is Lc(h/kt)1/2

and not Lc(2h/kt)1/2 as in Eq. (4.13-15).

Figure 4.13-5. Fin efficiency ηf for various fins: (a) longitudinal or straight fins, (b) circular or transverse fins.

(See Fig. 4.13-3 for the dimensions of the fins.)
EXAMPLE 4.13.-2. Fin Efficiency and Heat Loss from Fin
A circular aluminum fin as shown in Fig. 4.13-3b (k = 222 W/m · K) is attached to a copper
tube having an outside radius of 0.04 m. The length of the fin is 0.04 m and the thickness is 2
mm. The outside wall or tube base is at 523.2 K and the external surrounding air at 343.2 K
has a convective coefficient of 30 W/m2 · K. Calculate the fin efficiency and rate of heat loss
from the fin.

S olu t ion: The given data are T0 = 523.2 K, T∞ = 343.2 K, L = 0.04 m, r l = 0.04 m, t = 0.002

m, k = 222 W/m · K, h = 30 W/m2 · K. By Eq. (4.13-16), Lc = L + t/2 = 0.040 + 0.002/2 =
0.041 m. Then,

Also, (Lc + r 1)/r 1 = (0.041 + 0.040)/0.040 = 2.025. Using Fig. 4.13-5b, ηf = 0.89. The heat


transfer from the fin itself is

Equation 4.13-17

where Af is the outside surface area (annulus) of the fin and is given by the following for both
sides of the fin:

Equation 4.13-18
Hence,

Substituting into Eq. (4.13-17),

3. Ov er a ll hea t -t r a nsfer  coefficient  for  finned  t u b es

We consider here the general case similar to Fig. 4.3-3b, where heat transfer occurs from a fluid inside a
cylinder or tube, through the cylinder metal wall A of thickness ΔxA, and then to the fluid outside the
tube, where the tube has fins on the outside. The heat is transferred through a series of resistances. The
total heat q leaving the outside of the tube is the sum of heat loss by convection from the base of the bare
tube qt and the loss by convection from the fins, qf:

Equation 4.13-19

This can be written as a resistance since the paths are in parallel:

Equation 4.13-20

where At is the area of the bare tube between the fins, Af the area of the fins, and h0 the outside convective
coefficient. The resistance in Eq. (4.3-20) can be substituted for the resistance (1/h0A0) in Eq. (4.3-15) for
a bare tube to give the overall equation for a finned tube exchanger:

Equation 4.13-21
where T4 is the temperature of the fluid inside the tube and T1 the outside fluid temperature. Writing Eq.
(4.13-21) in the form of an overall heat-transfer coefficient Ui based on the inside area Ai, q = UiAi(T4 - T1)
and

Equation 4.13-22

The presence of fins on the outside of the tube changes the characteristics of the fluid flowing past the
tube (either flowing parallel to the longitudinal finned tube or transverse to the circular finned tube).
Hence, the correlations for fluid flow parallel to or transverse to bare tubes cannot be used to predict the
outside convective coefficient h0. Correlations are available in the literature (K4, M1, P1, P3) for heat
transfer to various types of fins.
                             
                                                 
                                             
                                               
     

4.14. DIMENSIONAL ANALYSIS IN HEAT TRANSFER

4 .14 A. Intr od u ction

As seen in many of the correlations for fluid flow and heat transfer, many dimensionless groups, such as
the Reynolds number and Prandtl number, occur in these correlations. Dimensional analysis is often
used to group the variables in a given physical situation into dimensionless parameters or numbers
which can be useful in experimentation and correlating data.

An important way of obtaining these dimensionless groups is to use dimensional analysis of differential
equations as described in Section 3.11. Another useful method is the Buckingham method, in which the
listing of the significant variables in the particular physical problem is done first. Then we determine the
number of dimensionless parameters into which the variables may be combined.

4 .14 B. Bu ckingham  M e thod

1. Hea t  t r a nsfer  insid e a  p ip e

The Buckingham theorem, given in Section 3.11, states that the function relationship among q quantities
or variables whose units may be given in terms of u fundamental units or dimensions may be written as
(q –u) dimensionless groups.

As an additional example to illustrate the use of this method, let us consider a fluid flowing in turbulent
flow at velocity v inside a pipe of diameter D and undergoing heat transfer to the wall. We wish to predict
the dimensionless groups relating the heat-transfer coefficient h to the variables D, ρ, μ, cp, k, and v. The
total number of variables is q = 7.

The fundamental units or dimensions are u = 4 and are mass M, length L, time t, and temperature T. The
units of the variables in terms of these fundamental units are as follows:

Hence, the number of dimensionless groups or π's can be assumed to be 7 – 4, or 3. Then

Equation 4.14-1

We will choose the four variables D, k, μ, and v to be common to all the dimensionless groups. Then the
three dimensionless groups are

Equation 4.14-2
Equation 4.14-3

Equation 4.14-4

For π1, substituting the actual dimensions,

Equation 4.14-5

Summing for each exponent,

Equation 4.14-6

Solving these equations simultaneously, a = 1, b = 0, c = -1, and d = 1.

Substituting these values into Eq. (4.14-2),

Equation 4.14-7

Repeating for π2 and π 3 and substituting the actual dimensions,

Equation 4.14-8
Equation 4.14-9

Substituting π1, π2, and π3 into Eq. (4.14-1) and rearranging,

Equation 4.14-10

This is in the form of the familiar equation for heat transfer inside pipes, Eq. (4.5-8).

This type of analysis is useful in empirical correlations of heat-transfer data. The importance of each
dimensionless group, however, must be determined by experimentation (B1, M1).

2. Na t u r a l conv ect ion hea t  t r a nsfer  ou t sid e a  v er t ica l p la ne

In the case of natural convection heat transfer from a vertical plane wall of length L to an adjacent fluid,
different dimension-less groups should be expected as compared to forced convection inside a pipe, since
velocity is not a variable. The buoyant force due to the difference in density between the cold and the
heated fluid should be a factor. As seen in Eqs. (4.7-1) and (4.7-2), the buoyant force depends upon the
variables β, g, ρ, and ΔT. Hence, the list of variables to be considered and their fundamental units are as
follows:

The number of variables is q = 9. Since u = 4, the number of dimensionless groups or π's is 9 - 4, or 5.
Then π1 = f(π2, π3, π4,π5).

We will choose the four variables L, μ, k, and g to be common to all the dimensionless groups:

For π1, substituting the dimensions,
Equation 4.14-11

Solving for the exponents as before,  , b = -1, c = 0, and  . Then π1 becomes

Equation 4.14-12

Taking the square of both sides to eliminate fractional exponents,

Equation 4.14-13

Repeating for the other π equations,

Combining the dimensionless groups π1, π3, and π4 as follows,

Equation 4.14-14

Equation (4.14-14) is the Grashof group given in Eq. (4.7-4). Hence,

Equation 4.14-15
                             
                                                 
                                             
                                               
     

4.15. NUMERICAL METHODS FOR STEADY­STATE CONDUCTION
IN TWO DIMENSIONS

4 .15A. Analytical Eq u ation for  C ond u ction

In Section 4.4 we discussed methods for solving two-dimensional heat-conduction problems using
graphical procedures and shape factors. In this section we consider analytical and numerical methods.

The equation for conduction in the x direction is as follows:

Equation 4.15-1

Now we shall derive an equation for steady-state conduction in two directions x and y. Referring to Fig.
4.15-1, a rectangular block Δx by Δy by L is shown. The total heat input to the block is equal to the
output:

Equation 4.15-2

Figure 4.15-1. Steady-state conduction in two directions.

Now, from Eq. (4.15-1),

Equation 4.15-3
Writing similar equations for the other three terms and substituting into Eq. (4.15-2),

Equation 4.15-4

[View full size image]

Dividing through by Δx ΔyL and letting Δx and Δy approach zero, we obtain the final equation for
steady-state conduction in two directions:

Equation 4.15-5

This is called the Laplace equation.. There are a number of analytical methods for solving this equation.
In the method of separation of variables, the final solution is expressed as an infinite Fourier series (H1,
G2, K1). We consider the case shown in Fig. 4.15-2. The solid is called a semi-infinite solid since one of its
dimensions is ∞. The two edges or boundaries at x = 0 and x = L are held constant at T1 K. The edge at y
= 0 is held at T2. And at y = ∞, T = T1. The solution relating T to position y and x is

Equation 4.15-6

Figure 4.15-2. Steady-state heat conduction in two directions in a semi-infinite plate.
Other analytical methods are available and are discussed in many texts (C2, H1, G2, K1). A large number
of such analytical solutions have been given in the literature. However, there are many practical
situations where the geometry or boundary conditions are too complex for analytical solutions, so that
finite-difference numerical methods are used. These are discussed in the next section.

4 .15B. Finite -Diffe r e nce  Nu m e r ical M e thod s

1. Der iv a t ion of t he met hod

Since the advent of fast digital computers, solutions to many complex two-dimensional heat-conduction
problems by numerical methods are readily possible. In deriving the equations we can start with the
partial differential equation (4.15-5). Setting up the finite difference of ∂·2T/∂·x2,

Equation 4.15-7

where the index m stands for a given value of y, m + 1 stands for y + 1 Δy, and n is the index indicating
the position of T on the x scale. This is shown in Fig. 4.15-3. The two-dimensional solid is divided into
squares. The solid inside a square is imagined to be concentrated at the center of the square, and this
concentrated mass is a "node." Each node is imagined to be connected to the adjacent nodes by a small
conducting rod as shown.

Figure 4.15-3. Temperatures and arrangement of nodes for two-dimensional steady-state heat conduction.
The finite difference of ∂·2T/∂·y 2 is written in a similar manner:

Equation 4.15-8

Substituting Eqs. (4.15-7) and (4.15-8) into Eq. (4.15-5) and setting Δx = Δy,

Equation 4.15-9

This equation states that the net heat flow into any point or node is zero at steady state. The shaded area
in Fig. 4.15-3 represents the area on which the heat balance was made. Alternatively, Eq. (4.15-9) can be
derived by making a heat balance on this shaded area. The total heat in for unit thickness is

Equation 4.15-10

[View full size image]

Rearranging, this becomes Eq. (4.15-9). In Fig. 4.15-3 the rods connecting the nodes act as fictitious
heat-conducting rods.
To use the numerical method, Eq. (4.15-9) is written for each node or point. Hence, for N unknown
nodes, N linear algebraic equations must be written and the system of equations solved for the various
node temperatures. For a hand calculation using a modest number of nodes, the iteration method can be
used to solve the system of equations.

2. It er a t ion met hod  of solu t ion

In using the iteration method, the right-hand side of Eq. (4.15-9) is set equal to a residual  :

Equation 4.15-11

Since   = 0 at steady state, solving for Tn,m in Eq. (4.15-11) or (4.15-9),

Equation 4.15-12

Equations (4.15-11) and (4.15-12) are the final equations to be used. Their use is illustrated in the
following example.

EXAMPLE 4.15-1. Steady-State Heat Conduction in Two
Directions
Figure 4.15-4 shows a cross section of a hollow rectangular chamber with inside dimensions 4
× 2 m and outside dimensions 8 × 8 m. The chamber is 20 m long. The inside walls are held at
600 K and the outside at 300 K. The k is 1.5 W/m · K. For steady-state conditions find the heat
loss per unit chamber length. Use grids 1 ×‐ 1 m.

Figure 4.15-4. Square grid pattern for Example 4.15-1.
S olu t ion: Since the chamber is symmetrical, one-fourth of the chamber (shaded part) will be
used. Preliminary estimates will be made for the first approximation: T1,2 = 450 K, T2,2 = 400,
T3,2 = 400, T3,3 = 400, T3,4 = 450, T3,5 = 500, T4,2 = 325, T4,3 = 350, T4,4 = 375, and T4,5 =
400. Note that T0,2 = T2,2, T3,6 = T3,4, and T4,6 = T4,4 by symmetry.

To start the calculation, one can select any interior point, but it is usually better to start near a

boundary. Using T1,2, we calculate the residual   by Eq. (4.15-11):

Hence, T1,2 is not at steady state. Next, we set   to 0 and calculate a new value of T1,2 by
Eq. (4.15-12):

This new value of T1,2 of 425 K will replace the old one of 450 and be used to calculate the other
nodes. Next,
Setting   to zero and using Eq. (4.15-12),

Continuing for all the rest of the interior nodes,

Using Eq. (4.15-12), T3,2 = 364,

Having completed one sweep across the grid map, we can start a second approximation,
using, of course, the new values calculated. We can start again with T1,2 or we can select the
node with the largest residual. Starting with T1,2 again,
This is continued until the residuals are as small as desired. The final values are as follows:

To calculate the total heat loss from the chamber per unit chamber length, we use Fig. 4.15-5.
For nodes T2,4 to T3,4 with Δx = Δy and 1 m deep,

Equation 4.15-13

Figure 4.15-5. Drawing for calculation of total heat conduction.

The heat flux for nodes T2,5 to T3,5 and for T1,3 to T1,2 should be multiplied by   because of
symmetry. The total heat conducted is the sum of the five paths for one-fourth of the solid. For
four duplicate parts,

Equation 4.15-14
Also, the total heat conducted can be calculated using the nodes at the outside, as shown in
Fig. 4.15-5. This gives qII = 3430 W. The average value is

If a larger number of nodes, that is, a smaller grid size, is used, a more accurate solution can be obtained.
Using a grid size of 0.5 m instead of 1.0 m for Example 4.15-1, a qav  of 3250 W is obtained. If a very fine
grid is used, more accuracy can be obtained, but a digital computer would be needed for the large number
of calculations. Matrix methods are also available for solving a set of simultaneous equations on a
computer. The iteration method used here is often called the Gauss-Seidel method. The simplest and
most convenient method is to use a spreadsheet calculation with a computer. This avoids the
complication of using complex matrix methods and so forth.

3. Eq u a t ions for  ot her  b ou nd a r y  cond it ions

In Example 4.15-1 the conditions at the boundaries were such that the node points were known and
constant. For the case where there is convection at the boundary to a constant temperature T∞, a heat
balance on the node n, m in Fig. 4.15-6a is as follows, where heat in = heat out (K1):

Equation 4.15-15

Figure 4.15-6. Other types of boundary conditions: (a) convection at a boundary, (b) insulated boundary, (c)
exterior corner with convective boundary, (d) interior corner with convective boundary.
Setting Δx = Δy, rearranging, and setting the resultant equation =   residual, the following results:

a.  For convection at a boundary,

Equation 4.15-16

In a similar manner, for the cases in Fig. 4.15-6:

b.  For an insulated boundary,

Equation 4.15-17

c.  For an exterior corner with convection at the boundary,

Equation 4.15-18
d.  For an interior corner with convection at the boundary,

Equation 4.15-19

[View full size image]

For curved boundaries and other types of boundaries, see (C3, K1). To use Eqs. (4.15-16)–(4.15-19), the

residual   is first obtained using the proper equation. Then   is set equal to zero and Tn,m solved


for in the resultant equation.
                             
                                                 
                                             
                                               
     

PROBLEMS
4 .1-1.
Insu la t ion in a  C old  R oom. Calculate the heat loss per m2 of surface area for a temporary
insulating wall of a food cold storage room where the outside temperature is 299.9 K and the
inside temperature 276.5 K. The wall is composed of 25.4 mm of corkboard having a k of 0.0433
W/m · K.
A1: Ans.  39.9 W/m2
4 .1-2.
Det er mina t ion of The r ma l C ond u ct iv it y . In determining the thermal conductivity of an
insulating material, the temperatures were measured on both sides of a flat slab of 25 mm of the
material and were 318.4 and 303.2 K. The heat flux was measured as 35.1 W/m2. Calculate the
thermal conductivity in btu/h · ft · °F and in W/m · K.
4 .2-1.
M ea n The r ma l C ond u ct iv it y  in a  C y lind er . Prove that if the thermal conductivity varies
linearly with temperature as in Eq. (4.1-11), the proper mean value km to use in the cylindrical
equation is given by Eq. (4.2-3) as in a slab.
4 .2-2.
Hea t  R emov a l of a  C ooling  C oil. A cooling coil of 1.0 ft of 304 stainless-steel tubing having
an inside diameter of 0.25 in. and an outside diameter of 0.40 in. is being used to remove heat
from a bath. The temperature at the inside surface of the tube is 40°F and is 80°F on the outside.
The thermal conductivity of 304 stainless steel is a function of temperature:

where k is in btu/h · ft · °F and T is in °F. Calculate the heat removal in btu/s and watts.
A4 :Ans. 1.225 btu/s, 1292 W
4 .2-3.
R emov a l of Hea t  fr om a  Ba t h.  Repeat Problem 4.2-2 but for a cooling coil made of 308
stainless steel having an average thermal conductivity of 15.23 W/m · K.
4 .2-4 .
Va r ia t ion of The r ma l C ond u ct iv it y . A flat plane of thickness Δx has one surface
maintained at T1 and the other at T2. If the thermal conductivity varies according to
temperature as

where a, b, and c are constants, derive an expression for the one-dimensional heat flux q/A.

4 .2-5.
Temp er a t u r e Dist r ib u t ion in a  Hollow  S p he r e. Derive Eq. (4.2-14) for the steady-state
conduction of heat in a hollow sphere. Also, derive an equation which shows that the
temperature varies hyperbolically with the radius r.
A7:
 

Ans.
4 .3-1.
Insu la t ion Need ed  for  Food  C old  S t or a g e R oom. A food cold storage room is to be
constructed of an inner layer of 19.1 mm of pine wood, a middle layer of cork board, and an outer
layer of 50.8 mm of concrete. The inside wall surface temperature is -17.8°C and the outside
surface temperature is 29.4°C at the outer concrete surface. The mean conductivities are for pine,
0.151; cork, 0.0433; and concrete, 0.762 W/m · K. The total inside surface area of the room to use
in the calculation is approximately 39 m2 (neglecting corner and end effects). What thickness of
cork board is needed to keep the heat loss to 586 W?
A8:Ans. 0.128 m thickness
4 .3-2.
Insu la t ion of a  Fu r na ce. A wall of a furnace 0.244 m thick is constructed of material having a
thermal conductivity of 1.30 W/m · K. The wall will be insulated on the outside with material
having an average k of 0.346 W/m · K, so the heat loss from the furnace will be equal to or less
than 1830 W/m2. The inner surface temperature is 1588 K and the outer 299 K. Calculate the
thickness of insulation required.
A9 :Ans. 0.179 m
4 .3-3.
Hea t  Loss Thr ou g h Ther mop a ne Dou b le W ind ow . A double window called ther-mopane
is one in which two layers of glass are separated by a layer of dry, stagnant air. In a given
window, each of the glass layers is 6.35 mm thick separated by a 6.35-mm space of stagnant air.
The thermal conductivity of the glass is 0.869 W/m · K and that of air is 0.026 over the
temperature range used. For a temperature drop of 27.8 K over the system, calculate the heat
loss for a window 0.914 m X 1.83 m. (Note: This calculation neglects the effect of the convective
coefficient on one outside surface of one side of the window, the convective coefficient on the
other outside surface, and convection inside the window.)
4 .3-4 .
Hea t  Loss fr om S t ea m Pip eline. A steel pipeline, 2-in. schedule 40 pipe, contains saturated
steam at 121.1°C. The line is covered with 25.4 mm of insulation. Assuming that the inside
surface temperature of the metal wall is at 121.1°C and the outer surface of the insulation is at
26.7°C, calculate the heat loss for 30.5 m of pipe. Also, calculate the kg of steam condensed per
hour in the pipe due to the heat loss. The average k for steel from Appendix A.3 is 45 W/m · K
and the k for the insulation is 0.182.
A11:Ans. 5384 W, 8.81 kg steam/h
4 .3-5.
Hea t  Loss w it h Tr ia l-a nd -Er r or  S olu t ion. The exhaust duct from a heater has an inside
diameter of 114.3 mm with ceramic walls 6.4 mm thick. The average k = 1.52 W/m · K. Outside
this wall, an insulation of rock wool 102 mm thick is installed. The thermal conductivity of the
rock wool is k = 0.046 + 1.56 × 10-4 T°C (W/m · K). The inside surface temperature of the
ceramic is T1 = 588.7 K, and the outside surface temperature of the insulation is T3 = 311 K.
Calculate the heat loss for 1.5 m of duct and the interface temperature T2 between the ceramic
and the insulation. [Hint: The correct value of km for the insulation is that evaluated at the
mean temperature of (T2 + T3)/2. Hence, for the first trial assume a mean temperature of, say,
448 K. Then calculate the heat loss and T2. Using this new T2, calculate a new mean
temperature and proceed as before.]
4 .3-6 .
Hea t  Loss b y  C onv ect ion a nd  C ond u ct ion. A glass window with an area of 0.557 m2 is
installed in the wooden outside wall of a room. The wall dimensions are 2.44 × 3.05 m. The
wood has a k of 0.1505 W/m · K and is 25.4 mm thick. The glass is 3.18 mm thick and has a k of
0.692. The inside room temperature is 299.9 K (26.7°C) and the outside air temperature is
266.5 K. The convection coefficient hi on the inside wall of the glass and the wood is estimated as

8.5 W/m2 · K; the outside h0 is also estimated as 8.5 for both surfaces. Calculate the heat loss
through the wooden wall, through the glass, and the total.
A13:Ans. 569.2 W (wood) (1942 btu/h), 77.6 W (glass) (265 btu/h), 646.8 W (total) (2207 btu/h)
4 .3-7.
C onv ect ion, C ond u ct ion, a nd  Ov er a ll U. A gas at 450 K is flowing inside a 2-in. steel pipe,
schedule 40. The pipe is insulated with 51 mm of lagging having a mean k = 0.0623 W/m · K.
The convective heat-transfer coefficient of the gas inside the pipe is 30.7 W/m2 · K and the
convective coefficient on the outside of the lagging is 10.8. The air is at a temperature of 300 K.

a.  Calculate the heat loss per unit length of 1 m of pipe using resistances.

b.  Repeat, using the overall U0 based on the outside area A0.

4 .3-8.
Hea t  Tr a nsfer  in S t ea m Hea t er . Water at an average of 70°F is flowing in a 2-in. steel pipe,
schedule 40. Steam at 220°F is condensing on the outside of the pipe. The convective coefficient
for the water inside the pipe is h = 500 btu/h · ft 2 · °F and the condensing steam coefficient on
the outside is h = 1500.

a.  Calculate the heat loss per unit length of 1 ft of pipe using resistances.

b.  Repeat, using the overall Ui based on the inside area Ai.

c.  Repeat, using Uo.

A15: Ans.  (a) q = 26 710 btu/h (7.828 kW), (b) U  = 329.1 btu/h · ft 2 · °F (1869 W/m2 · K), (c) U  =


i o
286.4 btu/h · ft 2 · °F (1626 W/m2 · K)
4 .3-9 .
Hea t  Loss fr om Temp er a t u r e M ea su r ement s. A steel pipe carrying steam has an outside
diameter of 89 mm. It is lagged with 76 mm of insulation having an average k = 0.043 W/m · K.
Two thermocouples, one located at the interface between the pipe wall and the insulation and
the other at the outer surface of the insulation, give temperatures of 115°C and 32°C,
respectively. Calculate the heat loss in W per m of pipe.
4 .3-10.
Effect  of C onv ect iv e C oefficient s on Hea t  Loss in Dou b le W ind ow . Repeat Problem 4.3-
3 for heat loss in the double window. However, include a convective coefficient of h = 11.35 W/m2
· K on one outside surface of one side of the window and an h of 11.35 on the other outside
surface. Also calculate the overall U.
A17: Ans.  q = 106.7 W, U = 2.29 W/m2 · K
4 .3-11.
Unifor m C hemica l Hea t  G ener a t ion. Heat is being generated uniformly by a chemical
reaction in a long cylinder of radius 91.4 mm. The generation rate is constant at 46.6 W/m3. The
walls of the cylinder are cooled so that the wall temperature is held at 311.0 K. The thermal
conductivity is 0.865 W/m · K. Calculate the center-line temperature at steady state.
A18:Ans. To = 311.112 K
4 .3-12.Hea t  of R esp ir a t ion of a  Food  Pr od u ct . A fresh food product is held in cold storage at 278.0
K. It is packed in a container in the shape of a flat slab with all faces insulated except for the top
flat surface, which is exposed to the air at 278.0 K. For estimation purposes the surface
temperature will be assumed to be 278 K. The slab is 152.4 mm thick and the exposed surface
area is 0.186 m2. The density of the foodstuff is 641 kg/m3. The heat of respiration is 0.070
kJ/kg · h and the thermal conductivity is 0.346 W/m · K. Calculate the maximum temperature
in the food product at steady state and the total heat given off in W. (Note: It is assumed in this
problem that there is no air circulation inside the foodstuff. Hence, the results will be
conservative, since circulation during respiration will reduce the temperature.)

A19 :Ans. 278.42 K, 0.353 W (1.22 btu/h)
4 .3-13.
Temp er a t u r e R ise in Hea t ing  W ir e. A current of 250 A is passing through a stainless-steel
wire having a diameter of 5.08 mm. The wire is 2.44 m long and has a resistance of 0.0843 Ω.
The outer surface is held constant at 427.6 K. The thermal conductivity is k = 22.5 W/m · K.
Calculate the center-line temperature at steady state.
4 .3-14 .
C r it ica l R a d iu s for  Insu la t ion. A metal steam pipe having an outside diameter of 30 mm
has a surface temperature of 400 K and is to be insulated with an insulation having a thickness
of 20 mm and a k of 0.08 W/m · K. The pipe is exposed to air at 300 K and a convection
coefficient of 30 W/m2 · K.

a.  Calculate the critical radius and the heat loss per m of length for the bare pipe.

b.  Calculate the heat loss for the insulated pipe assuming that the surface temperature of
the pipe remains constant.

A21:Ans. (b) q = 54.4 W
4 .4 -1.
C u r v ilinea r -S q u a r es G r a p hica l M et hod . Repeat Example 4.4-1 but with the following
changes:

a.  Select the number of equal temperature subdivisions between the isothermal boundaries
to be five instead of four. Draw in the curvilinear squares and determine the total heat
flux. Also calculate the shape factor S. Label each isotherm with the actual temperature.

b.  Repeat part (a), but in this case the thermal conductivity is not constant but k = 0.85 (1 +
0.00040T), where T is temperature in K. [Note: To calculate the overall q, the mean value
of k at the mean temperature is used. The spacing of the isotherms is independent of how
k varies with T (M1). However, the temperatures corresponding to the individual
isotherms are a function of how the value of k depends upon T. Write the equation for q'
for a given curvilinear section using the mean value of k over the temperature interval.
Equate this to the overall value of q divided by M or q/M. Then solve for the isotherm
temperature.]

4 .4 -2.
Hea t  Loss fr om a  Fu r na ce. A rectangular furnace with inside dimensions of 1.0 × 1.0 × 2.0 m
has a wall thickness of 0.20 m. The k of the walls is 0.95 W/m · K. The inside of the furnace is
held at 800 K and the outside at 350 K. Calculate the total heat loss from the furnace.
A23:Ans. q = 25 171 W
4 .4 -3.
Hea t  Loss fr om a  Bu r ied  Pip e. A water pipe whose wall temperature is 300 K has a diameter
of 150 mm and a length of 10 m. It is buried horizontally in the ground at a depth of 0.40 m
measured to the center line of the pipe. The ground surface temperature is 280 K and k = 0.85
W/m · K. Calculate the loss of heat from the pipe.
A24 :Ans. q = 451.2 W
4 .5-1.
Hea t ing  Air  b y  C ond ensing  S t ea m. Air is flowing through a tube having an inside diameter
of 38.1 mm at a velocity of 6.71 m/s, average temperature of 449.9 K, and pressure of 138 kPa.
The inside wall temperature is held constant at 204.4°C (477.6 K) by steam condensing outside
the tube wall. Calculate the heat-transfer coefficient for a long tube and the heat-transfer flux.

A25: Ans.  h =  39.38 W/m2 · K (6.94 btu/h · ft 2 · °F)


4 .5-2.

Tr ia l-a nd -Er r or  S olu t ion for  Hea t ing  W a t er . Water is flowing inside a horizontal 1 -in.


schedule 40 steel pipe at 37.8°C and a velocity of 1.52 m/s. Steam at 108.3°C is condensing on
the outside of the pipe wall and the steam coefficient is assumed constant at 9100 W/m2 · K.

a.  Calculate the convective coefficient hi for the water. (Note that this is trial and error. A
wall temperature on the inside must be assumed first.)

b.  Calculate the overall coefficient Ui based on the inside area and the heat-transfer flux q/Ai

in W/m2.

4 .5-3.
Hea t -Tr a nsfer  Ar ea  a nd  Use of Log  M ea n Temp er a t u r e Differ ence. A reaction mixture
having a cpm = 2.85 kJ/kg · K is flowing at a rate of 7260 kg/h and is to be cooled from 377.6 K to
344.3 K. Cooling water at 288.8 K is available and the flow rate is 4536 kg/h. The overall Uo is

653 W/m2 · K.

a.  For counterflow, calculate the outlet water temperature and the area Ao of the exchanger.

b.  Repeat for cocurrent flow.

A27: Ans.  (a) T  = 325.2 K, A  =  5.43 m2; (b) A  =  6.46 m2


1 o o
4 .5-4 .
Hea t ing  W a t er  w it h Hot  G a ses a nd  Hea t -Tr a nsfer  Ar ea . Water flowing at the rate of
13.85 kg/s is to be heated from 54.5 to 87.8°C in a heat exchanger by 54 430 kg/h of hot gas
flowing counterflow and entering at 427°C (cpm = 1.005 kJ/kg · K). The overall Uo = 69.1 W/m2 ·
K. Calculate the exit-gas temperature and the heat-transfer area.
A28:Ans. T = 299.5°C
4 .5-5.
C ooling  Oil a nd  Ov er a ll U. Oil flowing at the rate of 7258 kg/h with a cpm = 2.01 kJ/kg · K is
cooled from 394.3 K to 338.9 K in a counterflow heat exchanger by water entering at 294.3 K and
leaving at 305.4 K. Calculate the flow rate of the water and the overall Ui if the Ai is 5.11 m2.
A29 : Ans.  17 420 kg/h, U  =  686 W/m2 · K
i
4 .5-6 .
La mina r  Flow  a nd  Hea t ing  of Oil. A hydrocarbon oil having the same physical properties
as the oil in Example 4.5-5 enters at 175°F inside a pipe having an inside diameter of 0.0303 ft
and a length of 15 ft. The inside pipe surface temperature is constant at 325°F. The oil is to be
heated to 250°F in the pipe. How many lbm/h oil can be heated? (Hint: This solution is trial and
error. One method is to assume a flow rate of, say, m = 75 lb mass/h. Calculate the NRe and the
value of ha . Then make a heat balance to solve for q in terms of m. Equate this q to the q from the
equation q = ha A ΔTa . Solve for m. This is the new m to use for the second trial.)
A30:Ans. m = 84.2 lbm/h (38.2 kg/h)
4 .5-7.
Hea t ing  Air  b y  C ond ensing  S t ea m. Air at a pressure of 101.3 kPa and 288.8 K enters inside
a tube having an inside diameter of 12.7 mm and a length of 1.52 m with a velocity of 24.4 m/s.
Condensing steam on the outside of the tube maintains the inside wall temperature at 372.1 K.
Calculate the convection coefficient of the air. (Note: This solution is trial and error. First
assume an outlet temperature of the air.)
4 .5-8.
Hea t  Tr a nsfer  w it h a  Liq u id  M et a l. The liquid metal bismuth at a flow rate of 2.00 kg/s
enters a tube having an inside diameter of 35 mm at 425°C and is heated to 430°C in the tube.
The tube wall is maintained at a temperature of 25°C above the liquid bulk temperature.
Calculate the tube length required. The physical properties are as follows (H1): k = 15.6 W/m · K,
cp = 149 J/kg · K, μ = 1.34 ×‐ 10–3 Pa · s.
4 .6 -1.
Hea t  Tr a nsfer  fr om a  Fla t  Pla t e. Air at a pressure of 101.3 kPa and a temperature of 288.8 K
is flowing over a thin, smooth, flat plate at 3.05 m/s. The plate length in the direction of flow is
0.305 m and its temperature is 333.2 K. Calculate the heat-transfer coefficient assuming laminar
flow.
A33: Ans.  h =  12.35 W/m2 · K (2.18 btu/h · ft 2 · °F)
4 .6 -2.
C hilling  Fr ozen M ea t . Cold air at -28.9°C and 1 atm is recirculated at a velocity of 0.61 m/s
over the exposed top flat surface of a piece of frozen meat. The sides and bottom of this
rectangular slab of meat are insulated and the top surface is 254 mm by 254 mm square. If the
surface of the meat is at -6.7°C, predict the average heat-transfer coefficient to the surface. As an
approximation, assume that either Eq. (4.6-2) or (4.6-3) can be used, depending on the NRe,L.
A34 : Ans.  h =  6.05 W/m2 · K
4 .6 -3.
Hea t  Tr a nsfer  t o a n Ap p le. It is desired to predict the heat-transfer coefficient for air being
blown past an apple lying on a screen with large openings. The air velocity is 0.61 m/s at 101.32
kPa pressure and 316.5 K. The surface of the apple is at 277.6 K and its average diameter is 114
mm. Assume that it is a sphere.
4 .6 -4 .
Hea t ing  Air  b y  a  S t ea m Hea t er . A total of 13 610 kg/h of air at 1 atm abs pressure and
15.6°C is to be heated by passing over a bank of tubes in which steam at 100°C is condensing.
The tubes are 12.7 mm OD, 0.61 m long, and arranged in-line in a square pattern with Sp = Sn  =
19.05 mm. The bank of tubes contains six transverse rows in the direction of flow and 19 rows
normal to the flow. Assume that the tube surface temperature is constant at 93.33°C. Calculate
the outlet air temperature.

4 .7-1.
Na t u r a l C onv ect ion fr om a n Ov en W a ll. The oven wall in Example 4.7-1 is insulated so
that the surface temperature is 366.5 K instead of 505.4 K. Calculate the natural convection
heat-transfer coefficient and the heat-transfer rate per m of width. Use both Eq. (4.7-4) and the
simplified equation. (Note: Radiation is being neglected in this calculation.) Use both SI and
English units.
4 .7-2.Losses b y  Na t u r a l C onv ect ion fr om a  C y lind er . A vertical cylinder 76.2 mm in diameter
and 121.9 mm high is maintained at 397.1 K at its surface. It loses heat by natural convection to
air at 294.3 K. Heat is lost from the cylindrical side and the flat circular end at the top. Calculate
the heat loss neglecting radiation losses. Use the simplified equations of Table 4.7-2 and those
equations for the lowest range of NGr  NPr . The equivalent L to use for the top flat surface is 0.9
times the diameter.

A38:Ans. q = 26.0 W
4 .7-3.
Hea t  Loss fr om a  Hor izont a l Tu b e. A horizontal tube carrying hot water has a surface
temperature of 355.4 K and an outside diameter of 25.4 mm. The tube is exposed to room air at
294.3 K. What is the natural convection heat loss for a 1-m length of pipe?
4 .7-4 .
Na t u r a l C onv ect ion C ooling  of a n Or a ng e. An orange 102 mm in diameter having a
surface temperature of 21.1°C is placed on an open shelf in a refrigerator held at 4.4°C. Calculate
the heat loss by natural convection, neglecting radiation. As an approximation, the simplified
equation for vertical planes can be used with L replaced by the radius of the sphere (M1). For a
more accurate correlation, see (S2).
4 .7-5.
Na t u r a l C onv ect ion in Enclosed  Hor izont a l S p a ce. Repeat Example 4.7-3 but for the
case where the two plates are horizontal and the bottom plate is hotter than the upper plate.
Compare the results.
A4 1:Ans. q = 18.64 W
4 .7-6 .
Na t u r a l C onv ect ion Hea t  Loss in Dou b le W ind ow . A vertical double plate-glass window
has an enclosed air-gap space of 10 mm. The window is 2.0 m high by 1.2 m wide. One window
surface is at 25°C and the other at 10°C. Calculate the free convection heat-transfer rate through
the air gap.
4 .7-7.
Na t u r a l C onv ect ion Hea t  Loss for  W a t er  in Ver t ica l Pla t es. Two vertical square metal
plates having dimensions of 0.40 X 0.40 m are separated by a gap of 12 mm and this enclosed
space is filled with water. The average surface temperature of one plate is 65.6°C and the other
plate is at 37.8°C. Calculate the heat-transfer rate through this gap.
4 .7-8.
Hea t  Loss fr om a  Fu r na ce. Two horizontal metal plates having dimensions of 0.8 X 1.0 m
comprise the top of a furnace and are separated by a distance of 15 mm. The lower plate is at
400°C and the upper at 100°C, and air at 1 atm abs is enclosed in the gap. Calculate the heat-
transfer rate between the plates.
4 .8-1.
Boiling  C oefficient  in a  Ja ck et ed  K et t le. Predict the boiling heat-transfer coefficient for the
vertical jacketed sides of the kettle given in Example 4.8-1. Then, using this coefficient for the
sides and the coefficient from Example 4.8-1 for the bottom, predict the total heat transfer.
A4 5: Ans.  T  = 107.65°C, ΔT = 7.65 K, and h(vertical) = 3560 W/m2 · K
w
4 .8-2.
Boiling  C oefficient  on a  Hor izont a l Tu b e. Predict the boiling heat-transfer coefficient for

water under pressure boiling at 250°F for a horizontal surface of  -in.-thick stainless steel
having a k of 9.4 btu/h · ft · °F. The heating medium on the other side of this surface is a hot
fluid at 290°F having an h of 275 btu/h · ft 2 · °F. Use the simplified equations. Be sure to correct
this h value for the effect of pressure.
4 .8-3.
C ond ensa t ion on a  Ver t ica l Tu b e. Repeat Example 4.8-2 but for a vertical tube 1.22 m (4.0
ft) high instead of 0.305 m (1.0 ft) high. Use SI and English units.
A4 7: Ans.  h =  9438 W/m2 · K, 1663 btu/h · ft 2 · °F; N  = 207.2 (laminar flow)
Re
4 .8-4 .
C ond ensa t ion of S t ea m on Ver t ica l Tu b es. Steam at 1 atm abs pressure and 100°C is
condensing on a bank of five vertical tubes each 0.305 m high and having an OD of 25.4 mm.
The tubes are arranged in a bundle spaced far enough apart that they do not interfere with each
other. The surface temperature of the tubes is 97.78°C. Calculate the average heat-transfer
coefficient and the total kg condensate per hour.
A4 8: Ans.  h =  15 240 W/m2 · K
4 .8-5.
C ond ensa t ion on a  Ba nk  of Hor izont a l Tu b es. Steam at 1 atm abs pressure and 100°C is
condensing on a horizontal tube bank with five layers of tubes (N = 5) placed one below the
other. Each layer has four tubes (total tubes = 4 × 5 = 20) and the OD of each tube is 19.1 mm.
The tubes are each 0.61 m long and the tube surface temperature is 97.78°C. Calculate the
average heat-transfer coefficient and the kg condensate per second for the whole condenser.
Make a sketch of the tube bank.
4 .9 -1.
M ea n Temp er a t u r e Differ ence in a n Excha ng er . A 1-2 exchanger with one shell pass and
two tube passes is used to heat a cold fluid from 37.8°C to 121.1°C by using a hot fluid entering
at 315.6°C and leaving at 148.9°C. Calculate the ΔTlm and the mean temperature difference ΔTm
in K.
A50:Ans. ΔTlm = 148.9 K, ΔTm = 131.8 K
4 .9 -2.
C ooling  Oil b y  W a t er  in a n Excha ng er . Oil flowing at the rate of 5.04 kg/s (cpm = 2.09
kJ/kg · K) is cooled in a 1-2 heat exchanger from 366.5 K to 344.3 K by 2.02 kg/s of water
entering at 283.2 K. The overall heat-transfer coefficient Uo is 340 W/m2 · K. Calculate the area
required. (Hint: A heat balance must first be made to determine the outlet water temperature.)

4 .9 -3.
Hea t  Excha ng e Bet w een Oil a nd  W a t er . Water is flowing at the rate of 1.13 kg/s in a 1-2
shell-and-tube heat exchanger and is heated from 45°C to 85°C by an oil having a heat capacity
of 1.95 kJ/kg · K. The oil enters at 120°C and leaves at 85°C. Calculate the area of the exchanger
if the overall heat-transfer coefficient is 300 W/m2 · K.
4 .9 -4 .
Ou t let  Temp er a t u r e a nd  Effect iv eness of a n Excha ng er . Hot oil at a flow rate of 3.00
kg/s (cp = 1.92 kJ/kg · K) enters an existing counterflow exchanger at 400 K and is cooled by
water entering at 325 K (under pressure) and flowing at a rate of 0.70 kg/s. The overall U = 350
W/m2 · K and A = 12.9 m2. Calculate the heat-transfer rate and the exit oil temperature.
4 .10-1.
R a d ia t ion t o a  Tu b e fr om a  La r g e Enclosu r e. Repeat Example 4.10-1 but use the slightly
more accurate Eq. (4.10-5) with two different emissivities.
A54 :Ans. q = -2171 W (-7410 btu/h)
4 .10-2.
Ba k ing  a  Loa f of Br ea d  in a n Ov en. A loaf of bread having a surface temperature of 373 K is
being baked in an oven whose walls and the air are at 477.4 K. The bread moves continuously
through the large oven on an open chain belt conveyor. The emissivity of the bread is estimated
as 0.85, and the loaf can be assumed to be a rectangular solid 114.3 mm high × 114.3 mm wide ×
330 mm long. Calculate the radiation heat-transfer rate to the bread, assuming that it is small
compared to the oven and neglecting natural convection heat transfer.
A55:Ans. q = 278.4 W (950 btu/h)
4 .10-3.R a d ia t ion a nd  C onv ect ion fr om a  S t ea m Pip e. A horizontal oxidized steel pipe carrying
steam and having an OD of 0.1683 m has a surface temperature of 374.9 K and is exposed to air
at 297.1 K in a large enclosure. Calculate the heat loss for 0.305 m of pipe from natural
convection plus radiation. For the steel pipe, use an ε of 0.79.

A56 :Ans. q = 163.3 W (557 btu/h)
4 .10-4 .
R a d ia t ion a nd  C onv ect ion t o a  Loa f of Br ea d . Calculate the total heat-transfer rate to the
loaf of bread in Problem 4.10-2, including the radiation plus natural convection heat transfer.
For radiation first calculate a value of hr . For natural convection, use the simplified equations for
the lower NGr NPr  range. For the four vertical sides, the equation for vertical planes can be used
with an L of 114.3 mm. For the top surface, use the equation for a cooled plate facing upward,
and for the bottom, a cooled plate facing downward. The characteristic L for a horizontal
rectangular plate is the linear mean of the two dimensions.
4 .10-5.
Hea t  Loss fr om a  Pip e. A bare stainless-steel tube having an outside diameter of 76.2 mm
and an ε of 0.55 is placed horizontally in air at 294.2 K. The pipe surface temperature is 366.4 K.
Calculate the value of hc + hr  for convection plus radiation and the heat loss for 3 m of pipe.
4 .11-1.
R a d ia t ion S hield ing . Two very large and parallel planes each have an emissivity of 0.7.
Surface 1 is at 866.5 K and surface 2 is at 588.8 K. Use SI and English units.

a.  What is the net radiation loss of surface 1?

b.  To reduce this loss, two additional radiation shields also having an emissivity of 0.7 are
placed between the original surfaces. What is the new radiation loss?

A59 : Ans.  (a) 13 565 W/m2, 4304 btu/h · ft 2; (b) 4521 W/m2, 1435 btu/h · ft 2


4 .11-2.
R a d ia t ion fr om a  C r a ft  in S p a ce. A space satellite in the shape of a sphere is traveling in
outer space, where its surface temperature is held at 283.2 K. The sphere "sees" only outer space,
which can be considered as a black body with a temperature of 0 K. The polished surface of the
sphere has an emissivity of 0.1. Calculate the heat loss per m2 by radiation.
A6 0: Ans.  q /A  = 36.5 W/m2
12 1
4 .11-3.
R a d ia t ion a nd  C omp lex View  Fa ct or . Find the view factor F12 for the configuration shown
in Fig. P4.11-3. The area A4 and A3 are fictitious areas (C3). The area A2 + A4 is called A(24) and
A1 + A3 is called A(13). Areas A(24) and A(13) are perpendicular to each other. [Hint: Follow the
methods in Example 4.11-5. First, write an equation similar to Eq. (4.11-48) which relates the
interchange between A3 and A(24). Then relate the interchange between A(13) and A(24). Finally,
relate A(13) and A4.]

Figure P4.11-3. Geometric configuration for Problem 4.11-3.
A6 1:Ans. A1F12 = A(13)F(13)(24) + A3F34 - A3F3(24) - A(13)F(13)4
4 .11-4 .
R ad iation Be tw e e n Par alle l S u r face s. Two parallel surfaces each 1.83 × 1.83 m square are
spaced 0.91 m apart. The surface temperature of A1 is 811 K and that of A2 is 533 K. Both are
black surfaces.

a.  Calculate the radiant heat transfer between the two surfaces.

b.  Do the same as for part (a), but for the case where the two surfaces are connected by
nonconducting reradiating walls.

c.  Repeat part (b), but A1 has an emissivity of 0.8 and A2 an emissivity of 0.7.

4 .11-5.
R a d ia t ion Bet w een Ad ja cent  Per p end icu la r  Pla t es. Two adjacent rectangles are
perpendicular to each other. The first rectangle is 1.52 × 2.44 m and the second 1.83 × 2.44 m,
with the 2.44-m side common to both. The temperature of the first surface is 699 K and that of
the second is 478 K. Both surfaces are black. Calculate the radiant heat transfer between the two
surfaces.
4 .11-6 .View  Fa ct or  for  C omp lex G eomet r y . Using the dimensions given in Fig. P4.11-3, calculate
the individual view factors and also F12.
4 .11-7. R a d ia t ion fr om a  S u r fa ce t o t he S k y .  A plane surface having an area of 1.0 m2 is insulated
on the bottom side and is placed on the ground exposed to the atmosphere at night. The upper
surface is exposed to air at 290 K, and the convective heat-transfer coefficient from the air to the
plane is 12 W/m2 · K. The plane radiates to the clear sky. The effective radiation temperature of
the sky can be assumed as 80 K. If the plane is a black body, calculate the temperature of the
plane at equilibrium.
Ans.T = 266.5 K = -6.7°C
4 .11-8.
R a d ia t ion a nd  Hea t ing  of Pla nes. Two plane disks each 1.25 m in diameter are parallel and
directly opposite each other. They are separated by a distance of 0.5 m. Disk 1 is heated by
electrical resistance to 833.3 K. Both disks are insulated on all faces except the two faces directly
opposite each other. Assume that the surroundings emit no radiation and that the disks are in
space. Calculate the temperature of disk 2 at steady state and also the electrical energy input to
disk 1. (Hint: The fraction of heat lost from area number 1 to space is 1 – F12.)
A6 6 :Ans. F12 = 0.45, T2 = 682.5 K
4 .11-9 .R a d ia t ion b y  Disk s t o Ea ch Ot her  a nd  t o S u r r ou nd ing s. Two disks each 2.0 m in
diameter are parallel and directly opposite each other and are separated by a distance of 2.0 m.
Disk 1 is held at 1000 K by electric heating and disk 2 at 400 K by cooling water in a jacket at the
rear of the disk. The disks radiate only to each other and to the surrounding space at 300 K.
Calculate the electric heat input and also the heat removed by the cooling water.

4 .11-
2
10. View  Fa ct or  b y  Int eg r a t ion. A small black disk is vertical, with an area of 0.002 m , and
radiates to a vertical black plane surface that is 0.03 m wide and 2.0 m high and is opposite and
parallel to the small disk. The disk source is 2.0 m away from the vertical plane and placed
opposite the bottom of the plane. Determine F12 by integration of the view-factor equation.

A6 8:Ans. F12 = 0.00307
4 .11-11.
G a s R a d ia t ion t o G r a y  Enclosu r e. Repeat Example 4.11-7 but with the following changes:

a.  The interior walls are not black surfaces but gray surfaces with an emissivity of 0.75.

b.  The same conditions as part (a) with gray walls, but in addition heat is transferred by
natural convection to the interior walls. Assume an average convective coefficient of 8.0
W/m2 · K.

Ans.(b) q(convection + radiation) = 4.426 W
4 .11-
G a s R a d ia t ion a nd  C onv ect ion t o a  S t a ck . A furnace discharges hot flue gas at 1000 K and
12.
1 atm abs pressure containing 5% CO2 into a stack having an inside diameter of 0.50 m. The
inside walls of the refractory lining are at 900 K and the emissivity of the lining is 0.75. The
convective heat-transfer coefficient of the gas has been estimated as 10 W/m2 · K. Calculate the
rate of heat transfer q/A from the gas by radiation plus convection.
4 .12-1.
La mina r  Hea t  Tr a nsfer  of a  Pow er -La w  Flu id . A non-Newtonian power-law fluid banana
purée flowing at a rate of 300 lbm/h inside a 1.0-in.-ID tube is being heated by a hot fluid flowing
outside the tube. The banana purée enters the heating section of the tube, which is 5 ft long, at a
temperature of 60°F. The inside wall temperature is constant at 180°F. The fluid properties as
given by Charm (C1) are ρ = 69.9 lbm/ft 3, cp = 0.875 btu/lbm · °F, and k = 0.320 btu/h · ft · °F.
The fluid has the following rheological constants: n = n' = 0.458, which can be assumed
constant, and K = 0.146 lbf · sn  · ft -2 at 70°F and 0.0417 at 190°F A plot of log K versus T°F can
be assumed to be a straight line. Calculate the outlet bulk temperature of the fluid in laminar
flow.
4 .12-2.
Hea t ing  a  Pow er -La w  Flu id  in La mina r  Flow . A non-Newtonian power-law fluid having
the same physical properties and rheological constants as the fluid in Example 4.12-1 is flowing
in laminar flow at a rate of 6.30 × 10-2 kg/s inside a 25.4-mm-ID tube. It is being heated by a hot
fluid outside the tube. The fluid enters the heating section of the tube at 26.7°C and leaves the
heating section at an outlet bulk temperature of 46.1°C. The inside wall temperature is constant
at 82.2°C. Calculate the length of tube needed in m. (Note: In this case the unknown tube length
L appears in the equation for ha  and in the heat-balance equation.)
Ans.L = 1.722 m
4 .13-1.
Hea t  Tr a nsfer  in a  Ja ck et ed  Vessel w it h a  Pa d d le Ag it a t or . A vessel with a paddle
agitator and no baffles is used to heat a liquid at 37.8°C. A steam-heated jacket furnishes the
heat. The vessel's inside diameter is 1.22 m; the agitator diameter is 0.406 m and it is rotating at
150 rpm. The wall surface temperature is 93.3°C. The physical properties of the liquid are ρ =
977 kg/m3, cp = 2.72 kJ/kg · K, k = 0.346 W/m · K, and μ = 0.100 kg/m · s at 37.8°C and 7.5 ×

10–3 at 93.3°C. Calculate the heat-transfer coefficient to the wall of the jacket.
4 .13-2.
Hea t  Loss fr om C ir cu la r  Fins. Use the data and conditions from Example 4.13-2 and
calculate the fin efficiency and rate of heat loss from the following different fin materials:

a.  Carbon steel (k = 44 W/m · K).

b.  Stainless steel (k = 17.9 W/m · K).

A74 :Ans. (a) ηf = 0.66, q = 111.1 W
4 .13-3.
Hea t  Loss fr om Long it u d ina l Fin. A longitudinal aluminum fin as shown in Fig. 4.13-3a (k
= 230 W/m · K) is attached to a copper tube having an outside radius of 0.04 m. The length of
the fin is 0.080 m and the thickness is 3 mm. The tube base is held at 450 K and the external
surrounding air at 300 K has a convective coefficient of 25 W/m2 · K. Calculate the fin efficiency
and the heat loss from the fin per 1.0 m of length.
4 .13-4 .
Hea t  Tr a nsfer  in Finned  Tu b e Excha ng er . Air at an average temperature of 50°C is being
heated by flowing outside a steel tube (k = 45.1 W/m · K) having an inside diameter of 35 mm
and a wall thickness of 3 mm. The outside of the tube is covered with 16 longitudinal steel fins
with a length L = 13 mm and a thickness of t = 1.0 mm. Condensing steam inside at 120°C has a
coefficient of 7000 W/m2 · K. The outside coefficient of the air has been estimated as 30 W/m2 ·
K. Neglecting fouling factors and using a tube 1.0 m long, calculate the overall heat-transfer
coefficient Ui based on the inside area Ai.
4 .14 -1.
Dimensiona l Ana ly sis for  Na t u r a l C onv ect ion. Repeat the dimensional analysis for
natural convection heat transfer to a vertical plate as given in Section 4.14. However, do as
follows:

a.  Carry out all the detailed steps solving for all the exponents in the π's.

b.  Repeat, but in this case select the four variables L, μ, cp, and g to be common to all the
dimensionless groups.

4 .14 -2.
Dimensiona l Ana ly sis for  Unst ea d y -S t a t e C ond u ct ion. For unsteady-state conduction
in a solid, the following variables are involved: ρ, cp, L (dimension of solid), t, k, and z (location
in solid). Determine the dimensionless groups relating the variables.
A78:  

Ans.

4 .15-1.
Temp er a t u r es in a  S emi-Infinit e Pla t e. A semi-infinite plate is similar to that in Fig. 4.15-
2. At the surfaces x = 0 and x = L, the temperature is held constant at 200 K. At the surface y =
0, the temperature is held at 400 K. If L = 1.0 m, calculate the temperature at the point y = 0.5
m and x = 0.5 m at steady state.
4 .15-2.
Hea t  C ond u ct ion in a  Tw o-Dimensiona l S olid . For two-dimensional heat conduction as
given in Example 4.15-1, derive the equation to calculate the total heat loss from the chamber
per unit length using the nodes at the outside. There should be eight paths for one-fourth of the
chamber. Substitute the actual temperatures into the equation and obtain the heat loss.
Ans.q = 3426 W
4 .15-3.
S t ea d y -S t a t e Hea t  Loss fr om a  R ect a ng u la r  Du ct . A chamber that is in the shape of a
long, hollow, rectangular duct has outside dimensions of 3 × 4 m and inside dimensions of 1 × 2
m. The walls are 1 m thick. The inside surface temperature is constant at 800 K and the outside
constant at 200 K. The k = 1.4 W/m · K. Calculate the steady-state heat loss per unit m of length
of duct. Use a grid size of Δx = Δy = 0.5 m. Also, use the outside nodes to calculate the total heat
conduction. Use a spreadsheet for the calculation.
A80:Ans. q = 7428 W
4 .15-4 .
Tw o-Dimensiona l Hea t  C ond u ct ion a nd  Differ ent  Bou nd a r y  C ond it ions. A very long,
solid piece of material 1 by 1 m square has its top face maintained at a constant temperature of
1000 K and its left face at 200 K. The bottom face and right face are exposed to an environment
at 200 K and have a convection coefficient of h = 10 W/m2 · K. The k = 10 W/m · K. Use a grid

size of Δx = Δy =  m and calculate the steady-state temperatures of the various nodes.
4 .15-5.
Nod a l Point  a t  Ext er ior  C or ner  Bet w een Insu la t ed  S u r fa ces. Derive the finite-difference
equation for the case for the nodal point Tn,m at an exterior corner between insulated surfaces.
The diagram is similar to Fig. 4.15-6c except that the two boundaries are insulated.
A82:  

Ans.
                             
                                                 
                                             
                                               
     

Chapter 5. Principles of Unsteady­State Heat Transfer
                             
                                                 
                                             
                                               
     

5.1. DERIVATION OF BASIC EQUATION

5.1A. Intr od u ction

In Chapter 4 we considered various heat-transfer systems in which the temperature at any given point
and the heat flux were always constant over time, that is, in steady state. In the present chapter we will
study processes in which the temperature at any given point in the system changes with time, that is,
heat transfer is unsteady state or transient.

Before steady-state conditions can be reached in a process, some time must elapse after the heat-transfer
process is initiated to allow the unsteady-state conditions to disappear. For example, in Section 4.2A we
determined the heat flux through a wall at steady state. We did not consider the period during which one
side of the wall was being heated up and the temperatures were increasing.

Unsteady-state heat transfer is important because of the large number of heating and cooling problems
occurring industrially. In metallurgical processes it is necessary to predict cooling and heating rates for
various geometries of metals in order to predict the time required to reach certain temperatures. In food
processing, for example, the canning industry, perishable canned foods are heated by immersion in
steam baths or chilled by immersion in cold water. In the paper industry wood logs are immersed in
steam baths before processing. In most of these processes the material is suddenly immersed in a fluid of
higher or lower temperature.

5.1B. De r iv ation of Unste ad y-S tate  C ond u ction Eq u ation

To derive the equation for unsteady-state conduction in one direction in a solid, we refer to Fig. 5.1-1.
Heat is being conducted in the x direction in the cube Δx, Δy, Δz in size. For conduction in the x
direction, we write

Equation 5.1-1

Figure 5.1-1. Unsteady-state conduction in one direction.
The term ∂T/∂x means the partial or derivative of T with respect to x, with the other variables, y, z, and
time t, being held constant. Next, making a heat balance on the cube, we can write

Equation 5.1-2

The rate of heat input to the cube is

Equation 5.1-3

Also,

Equation 5.1-4

The rate of accumulation of heat in the volume Δx Δy Δz in time ∂t is

Equation 5.1-5

The rate of heat generation in volume Δx Δy Δz is

Equation 5.1-6
Substituting Eqs. (5.1-3)–(5.1-6) into (5.1-2) and dividing by Δx Δy Δz,

Equation 5.1-7

Letting Δx approach zero, we have the second partial of T with respect to x or ∂2T/∂x2 on the left side.
Then, rearranging,

Equation 5.1-8

where α is k/pcp, thermal diffusivity. This derivation assumes constant k, p, and cp. In SI units, α =

m2/s, T = K, t = s, k = W/m · K, p = kg/m3,  = W/m3, and cp = J/kg · K. In English units, α = ft 2/h, T =

°F, t = h, k = btu/h · ft·°F, ρ = lbm/ft 3,   = btu/h · ft 3, and cp = btu/lbm · °F.

For conduction in three dimensions, a similar derivation gives

Equation 5.1-9

In many cases, unsteady-state heat conduction is occurring but the rate of heat generation is zero. Then
Eqs. (5.1-8) and (5.1-9) become

Equation 5.1-10

Equation 5.1-11

Equations (5.1-10) and (5.1-11) relate the temperature T with position x, y, and z and time t. The
solutions of Eqs. (5.1-10) and (5.1-11) for certain specific cases as well as for the more general cases are
considered in much of the remainder of this chapter.
                             
                                                 
                                             
                                               
     

5.2. SIMPLIFIED CASE FOR SYSTEMS WITH NEGLIGIBLE
INTERNAL RESISTANCE

5.2A. Basic Eq u ation

We begin our treatment of transient heat conduction by analyzing a simplified case. In this situation we
consider a solid which has a very high thermal conductivity or very low internal conductive resistance
compared to the external surface resistance, where convection occurs from the external fluid to the
surface of the solid. Since the internal resistance is very small, the temperature within the solid is
essentially uniform at any given time.

An example would be a small, hot cube of steel at T0 K at time t = 0, suddenly immersed in a large bath of

cold water at T∞ which is held constant with time. Assume that the heat-transfer coefficient h in W/m2 ·
K is constant with time. Making a heat balance on the solid object for a small time interval of time dt s,
the heat transfer from the bath to the object must equal the change in internal energy of the object:

Equation 5.2-1

where A is the surface area of the object in m2, T the average temperature of the object at time t in s, ρ the
density of the object in kg/m3, and V the volume in m3. Rearranging the equation and integrating
between the limits of T = T0 when t = 0 and T = T when t = t,

Equation 5.2-2

Equation 5.2-3

This equation describes the time–temperature history of the solid object. The term cp ρV is often called
the lumped thermal capacitance of the system. This type of analysis is often called the lumped capacity
method or Newtonian heating or cooling method.

5.2B. Eq u ation for  Diffe r e nt G e om e tr ie s


In using Eq. (5.2-3) the surface/volume ratio of the object must be known. The basic assumption of
negligible internal resistance was made in the derivation. This assumption is reasonably accurate when

Equation 5.2-4

where hx1/k is called the Biot number NBi, which is dimensionless, and x1 is a characteristic dimension of
the body obtained from x1 = V/A. The Biot number compares the relative values of internal conduction
resistance and surface convective resistance to heat transfer.

For a sphere,

Equation 5.2-5

For a long cylinder,

Equation 5.2-6

For a long square rod,

Equation 5.2-7

EXAMPLE 5.2-1. Cooling of a Steel Ball
A steel ball having a radius of 1.0 in. (25.4 mm) is at a uniform temperature of 800°F (699.9
K). It is suddenly plunged into a medium whose temperature is held constant at 250°F (394.3
K). Assuming a convective coefficient of h = 2.0 btu/h · ft 2 · °F (11.36 W/m2 · K), calculate the
temperature of the ball after 1 h (3600 s). The average physical properties are k = 25 btu/h · ft ·
°F (43.3 W/m · K), ρ = 490 lbm/ft 3 (7849 kg/m3), and cp = 0.11 btu/lbm · °F (0.4606 kJ/kg ·
K). Use SI and English units.

S olu t ion: For a sphere from Eq. (5.2-5),
From Eq. (5.2-4) for the Biot number,

This value is <0.1; hence, the lumped capacity method can be used. Then,

Substituting into Eq. (5.2-3) for t = 1.0 h and solving for T,

5.2C . Total Am ou nt of He at Tr ansfe r r e d

The temperature of the solid at any time t can be calculated from Eq. (5.2-3). At any time t, the
instantaneous rate of heat transfer q(t) in W from the solid of negligible internal resistance can be
calculated from

Equation 5.2-8

Substituting the instantaneous temperature T from Eq. (5.2-3) into Eq. (5.2-8),

Equation 5.2-9
To determine the total amount of heat Q in W · s or J transferred from the solid from time t = 0 to t = t,
we can integrate Eq. (5.2-9):

Equation 5.2-10

Equation 5.2-11

EXAMPLE 5.2-2. Total Amount of Heat in Cooling
For the conditions in Example 5.2-1, calculate the total amount of heat removed up to time t =
3600 s.

S olu t ion: From Example 5.2-1, hA/cpρV = 3.71 × 10−4 s−1. Also, V = 4πr 3/3 = 4(π)

(0.0254)3/3 = 6.864 × 10−5 m3. Substituting into Eq. (5.2-11),
                             
                                                 
                                             
                                               
     

5.3. UNSTEADY­STATE HEAT CONDUCTION IN VARIOUS
GEOMETRIES

5.3A. Intr od u ction and  Analytical M e thod s

In Section 5.2 we considered a simplified case of negligible internal resistance where the object has a very
high thermal conductivity. Now we will consider the more general situation where the internal resistance
is not small, and hence the temperature is not constant in the solid. The first case that we shall consider
is one where the surface convective resistance is negligible compared to the internal resistance. This could
occur because of a very large heat-transfer coefficient at the surface or because of a relatively large
conductive resistance in the object.

To illustrate an analytical method of solving this first case, we will derive the equation for unsteady-state
conduction in the x direction only in a flat plate of thickness 2H as shown in Fig. 5.3-1. The initial profile
of the temperature in the plate at t = 0 is uniform at T = T0. At time t = 0, the ambient temperature is
suddenly changed to T1 and held there. Since there is no convection resistance, the temperature of the
surface is also held constant at T1. Since this is conduction in the x direction, Eq. (5.1-10) holds:

Equation 5.1-10

Figure 5.3-1. Unsteady-state conduction in a flat plate with negligible surface resistance.
The initial and boundary conditions are

Equation 5.3-1

Generally, it is convenient to define a dimensionless temperature Y so that it varies between 0 and 1.
Hence,

Equation 5.3-2

Substituting Eq. (5.3-2) into (5.1-10),

Equation 5.3-3

Redefining the boundary and initial conditions,

Equation 5.3-4

A convenient procedure to use to solve Eq. (5.3-3) is the method of separation of variables, which leads to
a product solution

Equation 5.3-5

where A and B are constants and a is a parameter. Applying the boundary and initial conditions of Eq.
(5.3-4) to solve for these constants in Eq. (5.3-5), the final solution is an infinite Fourier series (G1):
Equation 5.3-6

Hence from Eq. (5.3-6), the temperature T at any position x and time t can be determined. However,
these types of equations are very time-consuming to use, and convenient charts have been prepared,
which are discussed in Sections 5.3B, 5.3C, 5.3D, and 5.3E, where a surface resistance is present.

5.3B. Unste ad y-S tate  C ond u ction in a S e m i-infinite  S olid

In Fig. 5.3-2 a semi-infinite solid is shown that extends to ∞ in the +x direction. Heat conduction occurs
only in the x direction. Originally, the temperature in the solid is uniform at T0. At time t = 0, the solid is
suddenly exposed to or immersed in a large mass of ambient fluid at temperature T1, which is constant.

The convection coefficient h in W/m2 · K or btu/h · ft 2 · °F is present and is constant; that is, a surface
resistance is present. Hence, the temperature TS at the surface is not the same as T1.

Figure 5.3-2. Unsteady-state conduction in a semi-infinite solid.

The solution of Eq. (5.1-10) for these conditions has been obtained (S1) and is

Equation 5.3-7

where x is the distance into the solid from the surface in m (SI units), t = time in s, α = k/ρcp in m2/s. In

English units, x = ft, t = h, and α = ft 2/h. The function erfc is (1 − erf), where erf is the error function and
numerical values are tabulated in standard tables and texts (G1, P1, S1); Y is fraction of unaccomplished
change (T1 − T)/(T1 − T0); and 1 − Y is fraction of change.
Figure 5.3-3, calculated using Eq. (5.3-7), is a convenient plot used for unsteady-state heat conduction
into a semi-infinite solid with surface convection. If conduction into the solid is slow enough or h is very

large, the top line with   is used.

Figure 5.3-3. Unsteady-state heat conducted in a semi-infinite solid with surface convection. Calculated from
Eq. (5.3-7)(S1).

EXAMPLE 5.3-1. Freezing Temperature in the Ground
The depth in the soil of the earth at which freezing temperatures penetrate is often of
importance in agriculture and construction. On a certain fall day, the temperature in the earth
is constant at 15.6°C (60°F) to a depth of several meters. A cold wave suddenly reduces the air
temperature from 15.6 to −17.8°C (0°F). The convective coefficient above the soil is 11.36
W/m2 · K (2 btu/h · ft 2 · °F). The soil properties can be assumed as α = 4.65 × 10−7  m2/s
(0.018 ft 2/h) and k = 0.865 W/m · K (0.5 btu/h · ft · °F). Neglect any latent heat effects. Use SI
and English units.

a.  What is the surface temperature after 5 h?

b.  To what depth in the soil will the freezing temperature of 0°C (32°F) penetrate in 5 h?

S olu t ion: This is a case of unsteady-state conduction in a semi-infinite solid. For part (a), the
value of x which is the distance from the surface is x = 0 m. Then the value of   is
calculated as follows for t = 5 h, α = 4.65 × 10−7  m2/s, k = 0.865 W/m · °C, and h = 11.36
W/m2 · °C. Using SI and English units,

Also,

Using Fig. 5.3-3, for   = 0 and  , the value of 1 − Y = 0.63 is read off the


curve. Converting temperatures to K, T0 = 15.6°C + 273.2 = 288.8 K (60°F) and T1 = −17.8°C
+ 273.2 = 255.4 K (0°F). Then

Solving for T at the surface after 5 h,

For part (b), T = 273.2 K or 0°C, and the distance x is unknown. Substituting the known
values,

From Fig. 5.3-3 for (T − T0)/(T1 − T0) = 0.467 and  , a value of 0.16 is read off

the curve for  . Hence,
Solving for x, the distance the freezing temperature penetrates in 5 h,

5.3C . Unste ad y-S tate  C ond u ction in a Lar ge  Flat Plate

A geometry that often occurs in heat-conduction problems is a flat plate of thickness 2x1 in the x
direction and having large or infinite dimensions in the y and z directions, as shown in Fig. 5.3-4. Heat is
being conducted only from the two flat and parallel surfaces in the x direction. The original uniform
temperature of the plate is T0; at time t = 0, the solid is exposed to an environment at temperature T1
and unsteady-state conduction occurs. A surface resistance is present.

Figure 5.3-4. Unsteady-state conduction in a large flat plate.

The numerical results of this case are presented graphically in Figs. 5.3-5 and 5.3-6. Figure 5.3-5, from
Gurney and Lurie (G2), is a convenient chart for determining the temperatures at any position in the
plate and at any time t. The dimensionless parameters used in this and subsequent unsteady-state
charts in this section are given in Table 5.3-1 (x is the distance from the center of the flat plate, cylinder,
or sphere; x1 is one-half the thickness of the flat plate, radius of cylinder, or radius of sphere; x = distance
from the surface for a semi-infinite solid.)

Table 5.3-1. Dimensionless Parameters for Use in Unsteady-State Conduction Charts

SI units: α = m2 /s, T = K, t = s, x = m, x  = m, k = W/m · K, h = W/m2  · K


1

English units: α = ft2 /h, T = °F, t = h, x = ft, x  = ft, k = btu/h · ft · °F, h = btu/h · ft2  · °F


1

Cgs units: α = cm2 /s, T = °C, t = s, x = cm, x  = cm, k = cal/s · cm · °C, h = cal/s · cm2  · °C


1
Figure 5.3-5. Unsteady-state heat conduction in a large flat plate. [From H. P. Gurney and J. Lurie, Ind. Eng.
Chem., 15, 1170 (1923).]

Figure 5.3-6. Chart for determining temperature at the center of a large flat plate for unsteady-state heat
conduction. [From H. P. Heisler, Trans. A.S.M.E., 69, 227 (1947). With permission.]
When n = 0, the position is at the center of the plate in Fig. 5.3-5. Often the temperature history at the
center of the plate is quite important. A more accurate chart for determining only the center temperature
is given in Fig. 5.3-6, the Heisler (H1) chart. Heisler (H1) has also prepared multiple charts for
determining the temperatures at other positions.

EXAMPLE 5.3-2. Heat Conduction in a Slab of Butter
A rectangular slab of butter which is 46.2 mm thick at a temperature of 277.6 K (4.4°C) in a
cooler is removed and placed in an environment at 297.1 K (23.9°C). The sides and bottom of
the butter container can be considered to be insulated by the container side walls. The flat top
surface of the butter is exposed to the environment. The convective coefficient is constant at
8.52 W/m2 · K. Calculate the temperature in the butter at the surface, at 25.4 mm below the
surface, and at 46.2 mm below the surface at the insulated bottom after 5 h of exposure.

S olu t ion: The butter can be considered as a large, flat plate with conduction vertically in the x
direction. Since heat is entering only at the top face and the bottom face is insulated, the 46.2
mm of butter is equivalent to a half plate with thickness x1 = 46.2 mm. In a plate with two
exposed surfaces, as in Fig. 5.3-4, the center at x = 0 acts as an insulated surface, and both
halves are mirror images of each other.

The physical properties of butter from Appendix A.4 are k = 0.197 W/m · K, cp = 2.30 kJ/kg · K

= 2300 J/kg · K, and ρ = 998 kg/m3. The thermal diffusivity is

Also, x1 = 46.2/1000 = 0.0462 m.

The parameters needed for use in Fig. 5.3-5 are

For the top surface, where x = x1 = 0.0462 m,

Then, using Fig. 5.3-5,
Solving, T = 292.2 K (19.0°C).

At the point 25.4 mm from the top surface, or 20.8 mm from the center, x = 0.0208 m, and

From Fig. 5.3-5,

Solving, T = 288.3 K (15.1°C).

For the bottom point, or 0.0462 m from the top, x = 0 and

Then, from Fig. 5.3-5,

Solving, T = 287.4 K (14.2°C). Alternatively, using Fig. 5.3-6, which is only for the center
point, Y = 0.53 and T = 286.8 K (13.6°C).

5.3D. Unste ad y-S tate  C ond u ction in a Long C ylind e r

Here we consider unsteady-state conduction in a long cylinder where conduction occurs only in the
radial direction. The cylinder is long so that either conduction at the ends can be neglected or the ends
are insulated. Charts for this case are presented in Fig. 5.3-7 for determining the temperatures at any
position and Fig. 5.3-8 for the center temperature only.

Figure 5.3-7. Unsteady-state heat conduction in a long cylinder. [From H. P. Gurney and J. Lurie, Ind. Eng.
Chem., 15, 1170 (1923).]
Figure 5.3-8. Chart for determining temperature at the center of a long cylinder for unsteady-state heat
conduction. [From H. P. Heisler, Trans. A.S.M.E., 69, 227 (1947). With permission.]

[View full size image]
EXAMPLE 5.3-3. Transient Heat Conduction in a Can of
Pea Purée
A cylindrical can of pea purée (C2) has a diameter of 68.1 mm and a height of 101.6 mm and is
initially at a uniform temperature of 29.4°C. The cans are stacked vertically in a retort, and
steam at 115.6°C is admitted. For a heating time of 0.75 h at 115.6°C, calculate the
temperature at the center of the can. Assume that the can is in the center of a vertical stack of
cans and that it is insulated on its two ends by the other cans. The heat capacity of the metal
wall of the can will be neglected. The heat-transfer coefficient of the steam is estimated as 4540
W/m2 · K. Physical properties of purée are k = 0.830 W/m · K and α = 2.007 × 10−7  m2/s.

S olu t ion: Since the can is insulated at the two ends, we can consider it as a long cylinder. The
radius is x1 = 0.0681/2 = 0.03405 m. For the center with x = 0,

Also,

Using Fig. 5.3-8 from Heisler for the center temperature,

Solving, T = 104.4°C.
5.3E. Unste ad y-S tate  C ond u ction in a S p he r e

Figure 5.3-9 shows a chart by Gurney and Lurie for determining the temperatures at any position in a
sphere. Figure 5.3-10 is a chart by Heisler for determining only the center temperature in a sphere.

Figure 5.3-9. Unsteady-state heat conduction in a sphere. [From H. P. Gurney and J. Lurie, Ind. Eng. Chem., 
15, 1170 (1923).]

[View full size image]

Figure 5.3-10. Chart for determining the temperature at the center of a sphere for unsteady-state heat
conduction [From H. P. Heisler, Trans. A.S.M.E., 69, 227 (1947). With Permission.]

[View full size image]
5.3F. Unste ad y-S tate  C ond u ction in Tw o- and  Thr e e -Dim e nsional S yste m s

The heat-conduction problems considered so far have been limited to one dimension. However, many
practical problems involve simultaneous unsteady-state conduction in two and three directions. We
shall illustrate how to combine one-dimensional solutions to yield solutions for several-dimensional
systems.

Newman (N1) used the principle of superposition and showed mathematically how to combine the
solutions for one-dimensional heat conduction in the x, the y, and the z direction into an overall solution
for simultaneous conduction in all three directions. For example, a rectangular block with dimensions
2x1, 2y 1, and 2z1 is shown in Fig. 5.3-11. For the Y value in the x direction, as before,

Equation 5.3-8

Figure 5.3-11. Unsteady-state conduction in three directions in a rectangular block.
where Tx is the temperature at time t and position x distance from the center line, as before. Also, n =

x/x1, m = k/hx1, and  , as before. Then for the y direction,

Equation 5.3-9

and n = y/y 1, m = k/hy 1, and  . Similarly, for the z direction,

Equation 5.3-10

Then, for simultaneous transfer in all three directions,

Equation 5.3-11

where Tx,y,z is the temperature at the point x, y, z from the center of the rectangular block. The value of Yx
for the two parallel faces is obtained from Figs. 5.3-5 and 5.3-6 for conduction in a flat plate. The values
of Yy  and Yz are similarly obtained from the same charts.

For a short cylinder with radius x1 and length 2y 1, the following procedure is followed. First Yx for the
radical conduction is obtained from the figures for a long cylinder. Then Yy  for conduction between two
parallel planes is obtained from Fig. 5.3-5 or 5.3-6 for conduction in a flat plate. Then,

Equation 5.3-12

EXAMPLE 5.3-4. Two-Dimensional Conduction in a Short
Cylinder
Repeat Example 5.3-3 for transient conduction in a can of pea purée but assume that
conduction also occurs from the two flat ends.
S olu t ion: The can, which has a diameter of 68.1 mm and a height of 101.6 mm, is shown in
Fig. 5.3-12. The given values from Example 5.3-3 are x1 = 0.03405 m, y 1 = 0.1016/2 = 0.0508

m, k = 0.830 W/m · K, α = 2.007 × 10−7  m2/s, h = 4540 W/m2 · K, and t = 0.75(3600) = 2700
s.

Figure 5.3-12. Two dimensional conduction in a short cylinder in Example 5.3-4.

For conduction in the x (radial) direction as calculated previously,

From Fig. 5.3-8 for the center temperature,

For conduction in the y (axial) direction for the center temperature,

Using Fig. 5.3-6 for the center of a large plate (two parallel opposed planes),
Substituting into Eq. (5.3-12),

Then,

This compares with 104.4°C obtained in Example 5.3-3 for only radial conduction.

5.3G . C har ts for  Av e r age  Te m p e r atu r e  in a Plate , C ylind e r , and  S p he r e  w ith Ne gligib le
S u r face  R e sistance

If the surface resistance is negligible, the curves given in Fig. 5.3-13 will give the total fraction of
unaccomplished change, E, for slabs, cylinders, or spheres for unsteady-state conduction. The value of E
is

Equation 5.3-13

Figure 5.3-13. Unsteady-state conduction and average temperatures for negligible surface resistance. (From
R. E. Treybal, Mass Transfer Operations, 2nd ed. New York: McGraw-Hill Book Company, 1968. With
permission.)
where T0 is the original uniform temperature, T1 is the temperature of the environment to which the solid
is suddenly subjected, and Tav  is the average temperature of the solid after t hours.

The values of Ea , Eb, and Ec are each used for conduction between a pair of parallel faces, as in a plate.
For example, for conduction in the a and b directions in a rectangular bar,

Equation 5.3-14

For conduction from all three sets of faces,

Equation 5.3-15

For conduction in a short cylinder 2c long and radius a,

Equation 5.3-16
                             
                                                 
                                             
                                               
     

5.4. NUMERICAL FINITE­DIFFERENCE METHODS FOR UNSTEADY­
STATE CONDUCTION

5.4 A. Unste ad y-S tate  C ond u ction in a S lab

1. Int r od u ct ion

As discussed in previous sections of this chapter, the partial differential equations for unsteady-state
conduction in various simple geometries can be solved analytically if the boundary conditions are
constant at T = T1 with time. Also, in the solutions the initial profile of the temperature at t = 0 is
uniform at T = T0. The unsteady-state charts used also have these same boundary conditions and initial
condition. However, when the boundary conditions are not constant with time and/or the initial
conditions are not constant with position, numerical methods must be used.

Numerical calculation methods for unsteady-state heat conduction are similar to numerical methods for
steady state discussed in Section 4.15. The solid is subdivided into sections or slabs of equal length and a
fictitious node is placed at the center of each section. Then a heat balance is made for each node. This
method differs from the steady-state method in that we have heat accumulation in a node for unsteady-
state conduction. The methods are well suited for a spreadsheet calculation.

2. Eq u a t ions for  a  sla b

The unsteady-state equation for conduction in the x direction in a slab is

Equation 5.1-10

This can be set up for a numerical solution by expressing each partial derivative as an actual finite
difference in ΔT, Δt, and Δx. However, an alternative method will be used to derive the final result by
making a heat balance. Figure 5.4-1 shows a slab centered at position n, represented by the shaded area.
The slab has a width of Δx m and a cross-sectional area of A m2. The node at position n having a
temperature of Tn  is placed at the center of the shaded section; this node represents the total mass and
heat capacity of the section or slab. Each node is imagined to be connected to the adjacent node by a
fictitious, small conducting rod. (See Fig. 4.15-3 for an example.)

Figure 5.4-1. Unsteady-state conduction in a slab.
The figure shows the temperature profile at a given instant of time t s. Making a heat balance on this
node or slab, the rate of heat in – the rate of heat out = the rate of heat accumulation in Δt s:

Equation 5.4-1

where tTn  is the temperature at point n at time t and t+ΔtTn  is the temperature at point n at time t + 1 Δt


later. Rearranging and solving for t+ΔtTn ,

Equation 5.4-2

where

Equation 5.4-3

Note that in Eq. (5.4-2) the temperature t+ΔtTn  at position or node n and at a new time t + Δt is
calculated from the three points which are known at time t, the starting time. This is called the explicit
method, because the temperature at a new time can be calculated explicitly from the temperatures at the
previous time. In this method the calculation proceeds directly from one time increment to the next until
the final temperature distribution is calculated at the desired final time. Of course, the temperature
distribution at the initial time and the boundary conditions must be known.

Once the value of Δx has been selected, then from Eq. (5.4-3) a value of M or the time increment Δt may
be picked. For a given value of M, smaller values of Δx mean smaller values of Δt. The value of M must be
as follows:

Equation 5.4-4

If M is less than 2, the second law of thermodynamics is violated. It also can be shown that for stability
and convergence of the finite-difference solution, M must be ≥2.

Stability means the errors in the solution do not grow exponentially as the solution proceeds but damp
out. Convergence means that the solution of the difference equation approaches the exact solution of the
partial differential equation as Δt and Δx go to zero with M fixed. Using smaller sizes of Δt and Δx
increases the accuracy in general but greatly increases the number of calculations required. Hence, a
digital computer is often ideally suited for this type of calculation using a spreadsheet.

3. S imp lified  S chmid t  met hod  for  a  sla b

If the value of M = 2, then a great simplification of Eq. (5.4-2) occurs, giving the Schmidt method:

Equation 5.4-5

This means that when a time 1 Δt has elapsed, the new temperature at a given point n at t + Δt is the
arithmetic average of the temperatures at the two adjacent nodes n + 1 and n − 1 at the original time t.

5.4 B. Bou nd ar y C ond itions for  Nu m e r ical M e thod  for  a S lab

1. C onv ect ion a t  t he b ou nd a r y

For the case where there is a finite convective resistance at the boundary and the temperature of the
environment or fluid outside is suddenly changed to Ta , we can derive the following for a slab. Referring
to Fig. 5.4-1, we make a heat balance on the outside half-element. The rate of heat in by convection − the
rate of heat out by conduction = the rate of heat accumulations in Δt s:

Equation 5.4-6

where tT1.25 is the temperature at the midpoint of the 0.5 Δx outside slab. As an approximation, the
temperature T1 at the surface can be used to replace that of T1.25. Rearranging,

Equation 5.4-7
where

Equation 5.4-8

Note that the value of M must be such that

Equation 5.4-9

2. Insu la t ed  b ou nd a r y  cond it ion

In the case for the boundary condition where the rear face is insulated, a heat balance is made on the rear 

 slab just as on the front   slab in Fig. 5.4-1. The resulting equation is the same as Eqs. (5.4-6)
and (5.4-7), but h = 0 or N = 0 and tTf−1 = tTf+1 because of symmetry.

Equation 5.4-10

3. Alt er na t iv e conv ect iv e cond it ion

To use the equations above for a given problem, the same values of M, Δx, and Δt must be used. If N gets
too large, so that M may be inconveniently too large, another form of Eq. (5.4-7) can be derived. By
neglecting the heat accumulation in the front half-slab in Eq. (5.4-6),

Equation 5.4-11

Here the value of M is not restricted by the N value. This approximation works fairly well when a large
number of increments in Δx are used so that the amount of heat neglected is small compared to the total.

4 . Pr oced u r es for  u se of init ia l b ou nd a r y  t emp er a t u r e

When the temperature of the environment outside is suddenly changed to Ta , the following procedures
should be used.

1.  When M = 2 and a hand calculation of a limited number of increments is used, a special procedure
should be used in Eqs. (5.4-5) and (5.4-7) or (5.4-11). For the first time increment, one should use
an average value for 1Ta  of (Ta  + 0T1)/2, where 0T1 is the initial temperature at point 1. For all
succeeding Δt values, the value of Ta  should be used (D1, K1). This special procedure for
determining the value of Ta  to use for the first time increment increases the accuracy of the
numerical method, especially after a few time intervals. If Ta  varies with time t, a new value can be
used for each Δt interval.

2.  When M = 2 and many time increments are used with a digital computer, this special procedure is
not needed, and the same value of Ta  is used for all time increments.

3.  When M = 3 or more and a hand calculation of a limited number of increments or a digital-
computer calculation of many increments is used, only one value of Ta  is used for all time
increments. Note that when M = 3 or more, many more calculations are needed compared to the
case for M = 2. The most accurate results are obtained when M = 4, which is the preferred method,
with slightly less accurate results for M = 3 (D1, K1, K2).

EXAMPLE 5.4-1. Unsteady-State Conduction and the
Schmidt Numerical Method
A slab of material 1.00 m thick is at a uniform temperature of 100°C. The front surface is
suddenly exposed to a constant environmental temperature of 0°C. The convective resistance
is zero (h = ∞). The back surface of the slab is insulated. The thermal diffusivity α = 2.00 ×
10−5 m2/s. Using five slices each 0.20 m thick and the Schmidt numerical method with M =
2.0, calculate the temperature profile at t = 6000 s. Use the special procedure for the first time
increment.

S olu t ion: Figure 5.4-2 shows the temperature profile at t = 0 and the environmental
temperature of Tα = 0°C with five slices used. For the Schmidt method, M = 2. Substituting

into Eq. (5.4-3) with α = 2.00 × 10−5 and Δx = 0.20 and solving for Δt,

Equation 5.4-3

Figure 5.4-2. Temperature for numerical method, Example 5.4-1.
This means that (6000 s)/(1000 s/increment), or six time increments, must be used to reach
6000 s.

For the front surface, where n = 1, the temperature 1Ta  to use for the first Δt time increment, as
stated previously, is

Equation 5.4-12

where 0T1 is the initial temperature at point 1. For the remaining time increments,

Equation 5.4-13

To calculate the temperatures for all time increments for the slabs n = 2 to 5, using Eq. (5.4-5),

Equation 5.4-14

For the insulated end for all time increments at n = 6, substituting M = 2 and f = 6 into Eq.
(5.4-10),

Equation 5.4-15
For the first time increment of t + Δt, and calculating the temperature at n = 1 by Eq. (5.4-12),

For n = 2, using Eq. (5.4-14),

Continuing for n = 3, 4, 5, we have

For n = 6, using Eq. (5.4-15),

For 2 Δt, using Eq. (5.4-13) for n = 1, and continuing for n = 2 to 6, using Eqs. (5.4-14) and
(5.4-15),
For 3 Δt,

For 4 Δt,

For 5 Δt,
For 6 Δt (final time),

The temperature profiles for 3 Δt increments and the final time of 6 Δt increments are plotted
in Fig. 5.4-2. This example shows how a hand calculation can be done. To increase the
accuracy, more slab increments and more time increments are required. This, then, is ideally
suited for computation using a spreadsheet with a computer.

EXAMPLE 5.4-2. Unsteady-State Conduction Using the
Digital Computer
Repeat Example 5.4-1 using the digital computer. Use Δx = 0.05 m. Write the spreadsheet
program and compare the final temperatures with Example 5.4-1. Use the explicit method of
Schmidt for M = 2. Although not needed for many time increments using the digital computer,
use the special procedure for the value of 1Ta  for the first time increment. Thus a direct
comparison can be made with Example 5.4-1 of the effect of the number of increments on the
results.
S olu t ion: The number of slabs to use is 1.00 m/(0.05 m/slab) or 20 slabs. Substituting into
Eq. (5.4-3) with α = 2.00 × 10−5 m2/s, Δx = 0.05 m, and M = 2, and solving for Δt,

Hence, (6000/62.5) = 96 time increments to be used. The value of n goes from n = 1 to 21.

The equations to use to calculate the temperatures are again Eqs. (5.4-12)– (5.4-15). However,
the only differences are that in Eq. (5.4-14) n goes from 2 to 20, and in Eq. (5.4-15) n = 21, so
that t+ΔtT21 = tT20.

The spreadsheet for these equations is easily written and is left up to the reader. The results are
tabulated in Table 5.4-1 for comparison with Example 5.4-1, where only five slices were used.
The table shows that the results for five slices are reasonably close to those for 20 slices, with
values in both cases deviating by 2% or less from each other.

Table 5.4-1. Comparison of Results for Examples 5.4-1 and 5.4-2

  Results Using Δx = 0.20 m Results Using Δx = 0.05 m

Distance from Front Face   Temperature   Temperature

m n °C n °C

0 1 0.0 1 0.0

0.20 2 31.25 5 31.65

0.40 3 58.59 9 58.47

0.60 4 78.13 13 77.55

0.80 5 89.84 17 88.41


1.00 6 93.75 21 91.87

As a rule-of-thumb guide for hand calculations, using a minimum of five slices and at least 8–10 time
increments should give sufficient accuracy for most purposes. Only when very high accuracy is desired or
several cases are to be solved is it desirable to solve the problem using a spreadsheet calculation with a
computer.

EXAMPLE 5.4-3. Unsteady-State Conduction with
Convective Boundary Condition
Use the same conditions as Example 5.4-1, but a convective coefficient of h = 25.0 W/m2 · K is
now present at the surface. The thermal conductivity k = 10.0 W/m · K.

S olu t ion: Equations (5.4-7) and (5.4-8) can be used for convection at the surface. From Eq.
(5.4-8), N = hΔ×/k = 25.0(0.20)/10.0 = 0.50. Then 2N + 2 = 2(0.50) + 2 = 3.0. However, by
Eq. (5.4-9), the value of M must be equal to or greater than 2N + 2. This means that a value of
M = 2 cannot be used. We will select the preferred method where M = 4.0. [Another, less
accurate alternative is to use Eq. (5.4-11) for convection, and then the value of M is not
restricted by the N value.]

Substituting into Eq. (5.4-3) and solving for Δt,

Hence, 6000/500 = 12 time increments must be used.

For the first Δt time increment and for all time increments, the value of the environmental
temperature Ta  to use is Ta  = 0°C since M > 3. For convection at the node or point n = 1 we use
Eq. (5.4-7), where M = 4 and N = 0.50:

Equation 5.4-16

For n = 2, 3, 4, 5, we use Eq. (5.4-2),

Equation 5.4-17

For n = 6 (insulated boundary), we use Eq. (5.4-10) and f = 6.

Equation 5.4-18

For 1 Δt, for the first time increment of t + Δt, Ta  = 0. Using Eq. (5.4-16) to calculate the
temperature at node 1,

For n = 2, 3, 4, 5, using Eq. (5.4-17),
Also, in a similar calculation, T3, T4, and T5 = 100.0. For n = 6, using Eq. (5.4-18), T6 = 100.0.

For 2 Δt, Ta  = 0. Using Eq. (5.4-16),

Using Eq. (5.4-17) for n = 2, 3, 4, 5,

Also, T4 and T5 = 100.0. For n = 6, using Eq. (5.4-18), T6 = 100.0.

For 3 Δt, Ta  = 0. Using Eq. (5.4-16),

Using Eq. (5.4-17) for n = 2, 3, 4, 5,

Also, T5 = 100.0 and T6 = 100.0.

In a similar manner the calculations can be continued for the remaining time until a total of 12
Δt increments have been used.

5.4 C . Othe r  Nu m e r ical M e thod s for  Unste ad y-S tate  C ond u ction

1. Unst ea d y -st a t e cond u ct ion in a  cy lind er

In deriving the numerical equations for unsteady-state conduction in a flat slab, the cross-sectional area
was constant throughout. In a cylinder it changes radially. To derive the equation for a cylinder, Fig. 5.4-
3 is used, where the cylinder is divided into concentric hollow cylinders whose walls are Δ× m thick.
Assuming a cylinder 1 m long and making a heat balance on the slab at point n, the rate of heat in − rate
of heat out = rate of heat accumulation:

Equation 5.4-19
Figure 5.4-3. Unsteady-state conduction in a cylinder.

Rearranging, the final equation is

Equation 5.4-20

where M = (Δ×)2/(α Δt) as before. Also, at the center where n = 0,

Equation 5.4-21

To use Equations (5.4-20) and (5.4-21),

Equation 5.4-22

Equations for convection at the outer surface of the cylinder have been derived (D1). If the heat capacity
of the outer half-slab is neglected,

Equation 5.4-23
where Tn  is the temperature at the surface and Tn−1 the temperature at a position in the solid 1 Δ× below
the surface.

Equations for numerical methods for two-dimensional unsteady-state conduction have been derived and
are available in a number of references (D1, K2).

2. Unst ea d y -st a t e cond u ct ion a nd  imp licit  nu mer ica l met hod

In some practical problems the restrictions imposed on the value M ≥ 2 by stability requirements may
prove inconvenient.Also, to minimize the stability problems, implicit methods using different finite-
difference formulas have been developed.An important one of these formulas is the Crank–Nicolson
method, which will be considered here.

In deriving Eqs. (5.4-1) and (5.4-2), the rate at which heat entered the slab in Fig. 5.4-1 was taken to be
the rate at time t:

Equation 5.4-24

It was then assumed that this rate could be used during the whole interval from t to t + Δt. This is an
approximation, however since the rate changes during this Δt interval. A better value would be the
average value of the rate at t and at t + Δt, or

Equation 5.4-25

For the heat leaving, a similar type of average is used. The final equation is

Equation 5.4-26

This means that now a new value of t+ΔtTn  cannot be calculated only from values at time t, as in Eq.
(5.4-2), but that all the new values of T at t + Δt at all points must be calculated simultaneously. To do
this, an equation similar to Eq. (5.4-26) is written for each of the internal points. Each of these equations
and the boundary equations are linear algebraic equations. These then can be solved simultaneously by
the standard methods, such as the Gauss–Seidel iteration technique, matrix inversion technique, and so
on (G1, K1).
An important advantage of Eq. (5.4-26) is that the stability and convergence criteria are satisfied for all
positive values of M. This means that M can have values less than 2.0. A disadvantage of the implicit
method is the larger number of calculations needed for each time step. Explicit methods are simpler to
use, but because of stability considerations, especially in complex situations, implicit methods are often
preferred.
                             
                                                 
                                             
                                               
     

5.5. CHILLING AND FREEZING OF FOOD AND BIOLOGICAL
MATERIALS

5.5A. Intr od u ction

Unlike many inorganic and organic materials which are relatively stable, food and other biological
materials decay and deteriorate more or less rapidly with time at room temperature. This spoilage is due
to a number of factors. Tissues of foods such as fruits and vegetables continue to undergo metabolic
respiration after harvesting, and ripen and eventually spoil. Enzymes of the dead tissues of meats and
fish remain active and induce oxidation and other deteriorating effects. Microorganisms attack all types
of foods by decomposing the foods so that spoilage occurs; chemical reactions also occur, such as the
oxidation of fats.

At low temperatures the growth rate of microorganisms will be slowed if the temperature is below that
which is optimum for growth. Enzyme activity and chemical reaction rates are also reduced at low
temperatures. The rates of most chemical and biological reactions in storage of chilled or frozen foods and

biological materials are reduced by factors of   to   for each 10 K (10°C) drop in temperature.

Water plays an important part in these rates of deterioration, and it is present to a substantial
percentage in most biological materials. To reach a temperature low enough for most of these rates to
approximately cease, most of the water must be frozen. Materials such as food do not freeze at 0°C
(32°F), as pure water does, but at a range of temperatures below 0°C. However, because of some of the
physical effects of ice crystals and other effects, such as concentrating of solutions, chilling of biological
materials is often used for preservation instead of freezing.

Chilling of materials involves removing the sensible heat and heat of metabolism and reducing the
temperature, usually to a range of 4.4°C (40°F) to just above freezing. Essentially no latent heat of
freezing is involved. The materials can be stored for a week or so up to a few months, depending on the
product stored and the gaseous atmosphere. Each material has its optimum chill storage temperature.

In the freezing of food and biological materials, the temperature is reduced so that most of the water is
frozen to ice. Depending on the final storage temperature, down to as low as −30°C, the materials can be
stored for up to a year or so. Often in the production of frozen foods, they are first treated by blanching or
scalding to destroy enzymes.

5.5B. C hilling of Food  and  Biological M ate r ials

In the chilling of food and biological materials, the temperature of the materials is reduced to the desired
chill storage temperature, which can be about −1.1°C (30°F) to 4.4°C (40°F). For example, after
slaughter, beef has a temperature of 37.8°C (100°F) to 40°C (104°F), and it is often cooled to about
4.4°C (40°F). Milk from cows must be chilled quickly to temperatures just above freezing. Some fish
fillets at the time of packing are at a temperature of 7.2°C (45°F) to 10°C (50°F) and are chilled to close to
0°C.
These rates of chilling or cooling are governed by the laws of unsteady-state heat conduction discussed in
Sections 5.1 to 5.4. The heat is removed by convection at the surface of the material and by unsteady-
state conduction in the material. The fluid outside the foodstuff or biological materials is used to remove
this heat; in many cases it is air. The air has previously been cooled by refrigeration to −1.1°C to +4.4°C,
depending on the material and other conditions. The convective heat-transfer coefficients, which usually
include radiation effects, can also be predicted by the methods in Chapter 4; for air the coefficient varies
from about 8.5 to 40 W/m2 · K (1.5 to 7 btu/h · ft 2 · °F), depending primarily on air velocity.

In some cases the fluid used for chilling is a liquid flowing over the surface, and the values of h can vary
from about 280 to 1700 W/m2 · K (50–300 btu/h · ft 2 · °F). In other cases, a contact or plate cooler is
used, where chilled plates are in direct contact with the material. Then the temperature of the surface of
the material is usually assumed to be equal or close to that of the contact plates. Contact freezers are used
for freezing biological materials.

Where the food is packaged in boxes or the material is tightly covered by a film of plastic, this additional
resistance must be considered. One method for doing this is to add the resistance of the package covering
to that of the convective film:

Equation 5.5-1

where RP is the resistance of covering, RC the resistance of the outside convective film, and RT the total
resistance. Then, for each resistance,

Equation 5.5-2

Equation 5.5-3

Equation 5.5-4

where hc is the convective gas or liquid coefficient, A is the area, Δ× is the thickness of the covering, k is
the thermal conductivity of the covering, and h is the overall coefficient. The overall coefficient h is the
one to use in the unsteady-state charts. This assumes a negligible heat capacity of the covering, which is
usually the case. Also, it assumes that the covering closely touches the food material so there is no
resistance between the covering and the food.
The major sources of error in using the unsteady-state charts are inadequate data on the density, heat
capacity, and thermal conductivity of the foods and the prediction of the convective coefficient. Food
materials are irregular anisotropic substances, whose physical properties are often difficult to evaluate.
Also, if evaporation of water occurs on chilling, latent heat losses can affect the accuracy of the results.

EXAMPLE 5.5-1. Chilling Dressed Beef
Hodgson (H2) gives physical properties of beef carcasses during chilling of ρ = 1073 kg/m3, cp
= 3.48 kJ/kg · K, and k = 0.498 W/m · K. A large slab of beef 0.203 m thick and initially at a
uniform temperature of 37.8°C is to be cooled so that the center temperature is 10°C. Chilled
air at 1.7°C (assumed constant) with an h = 39.7 W/m2 · K is used. Calculate the time needed.

S olu t ion: The thermal diffusivity α is

Then, for the half-thickness x1 of the slab,

For the center of the slab,

Also,

Using Fig. 5.3-6 for the center of a large flat plate,

Solving, t = 6.95 × 104 s (19.3 h).
5.5C . Fr e e zing of Food  and  Biological M ate r ials

1. Int r od u ct ion

In the freezing of food and other biological materials, the removal of sensible heat in chilling occurs first
and then the removal of the latent heat of freezing. The latent heat of freezing water of 335 kJ/kg (144
btu/lbm) is a substantial portion of the total heat removed on freezing. Other slight effects, such as the
heats of solution of salts and so on, may be present but are quite small. Actually, when materials such as
meats are frozen to −29°C, only about 90% of the water is frozen to ice, with the rest thought to be bound
water (B1).

Riedel (R1) gives enthalpy–temperature–composition charts for the freezing of many different foods.
These charts show that freezing does not occur at a given temperature but extends over a range of several
degrees. As a consequence, there is no one freezing point with a single latent heat of freezing.

Since the latent heat of freezing is present in the unsteady-state process of freezing, the standard
unsteady-state conduction equations and charts given in this chapter cannot be used for prediction of
freezing times. A full analytical solution of the rate of freezing of food and biological materials is very
difficult because of the variation of physical properties with temperature, the amount of freezing varying
with temperature, and other factors. An approximate solution by Plank is often used.

2. Ap p r oxima t e solu t ion of Pla nk  for  fr eezing

Plank (P2) has derived an approximate solution for the time of freezing which is often sufficient for
engineering purposes. The assumptions in the derivation are as follows. Initially, all the food is at the
freezing temperature but is unfrozen. The thermal conductivity of the frozen part is constant. All the
material freezes at the freezing point, with a constant latent heat. The heat transfer by conduction in the
frozen layer occurs slowly enough that it is under pseudo-steady-state conditions.

In Fig. 5.5-1 a slab of thickness a m is cooled from both sides by convection. At a given time t s, a
thickness of x m of frozen layer has formed on both sides. The temperature of the environment is constant
at T1 K and the freezing temperature is constant at Tf. An unfrozen layer in the center at Tf is present.

Figure 5.5-1. Temperature profile during freezing.
The heat leaving at time t is q W. Since we are at pseudo-steady state, at time t, the heat leaving by
convection on the outside is

Equation 5.5-5

where A is the surface area. Also, the heat being conducted through the frozen layer of x thickness at
steady state is

Equation 5.5-6

where k is the thermal conductivity of the frozen material. In a given time dt s, a layer dx thick of
material freezes. Then multiplying A times dx times ρ gives the kg mass frozen. Multiplying this by the
latent heat λ in J/kg and dividing by dt,

Equation 5.5-7

where ρ is the density of the unfrozen material.

Next, to eliminate TS from Eqs. (5.5-5) and (5.5-6), Eq. (5.5-5) is solved for TS and substituted into Eq.
(5.5-6), giving

Equation 5.5-8

Equating Eq. (5.5-8) to (5.5-7),

Equation 5.5-9

Rearranging and integrating between t = 0 and x = 0, to t = t and x = a/2,

Equation 5.5-10
Integrating and solving for t,

Equation 5.5-11

To generalize the equation for other shapes,

Equation 5.5-12

where a is the thickness of an infinite slab (as in Fig. 5.5-1), diameter of a sphere, diameter of a long
cylinder, or smallest dimension of a rectangular block or brick. Also,

For a rectangular brick having dimensions a by β 1a by β 2a, where a is the shortest side, Ede (B1) has


prepared a chart to determine the values of P and R to be used to calculate t in Eq. (5.5-12). Equation
(5.5-11) can also be used for calculation of thawing times by replacing the k of the frozen material by the k
of the thawed material.

EXAMPLE 5.5-2. Freezing of Meat
Slabs of meat 0.0635 m thick are to be frozen in an air-blast freezer at 244.3 K (−28.9°C). The
meat is initially at the freezing temperature of 270.4 K (−2.8°C). The meat contains 75%
moisture. The heat-transfer coefficient is h = 17.0 W/m2 · K. The physical properties are ρ =
1057 kg/m3 for the unfrozen meat and k = 1.038 W/m · K for the frozen meat. Calculate the
freezing time.

S olu t ion: Since the latent heat of fusion of water to ice is 335 kJ/kg (144 btu/lbm), for meat
with 75% water,
The other given variables are a = 0.0635 m, Tf = 270.4 K, T1 = 244.3 K, ρ = 1057 kg/m3, h =

17.0 W/m2 · K, k = 1.038 W/m · K. Substituting into Eq. (5.5-11),

3. Ot her  met hod s for  ca lcu la t ing  fr eezing  t imes

Neumann (C1, C2) has derived a complicated equation for freezing in a slab. He assumes the following
conditions. The surface temperature is the same as the environment, that is, no surface resistance. The
temperature of freezing is constant. This method suffers from the limitation that a convection coefficient
cannot be used at the surface, since it assumes no surface resistance. However, the method does include
the effect of cooling from an original temperature, which may be above the freezing point.

Plank's equation does not make provision for an original temperature, which may be above the freezing
point. An approximate method for calculating the additional time necessary to cool from temperature T0
down to the freezing point Tf is as follows. Using the unsteady-state charts calculate the time for the
average temperature in the material to reach Tf, assuming that no freezing occurs and using the physical
properties of the unfrozen material. If there is no surface resistance, Fig. 5.3-13 can be used directly for
this. If a resistance is present, the temperature at several points in the material will have to be obtained
from the unsteady-state charts and the average temperature calculated from these point temperatures.
This may be partially trial and error, since the time is unknown and must be assumed. If the average
temperature calculated is not at the freezing point, a new time must be assumed. This is an approximate
method since some material will actually freeze.
                             
                                                 
                                             
                                               
     

5.6. DIFFERENTIAL EQUATION OF ENERGY CHANGE

5.6 A. Intr od u ction

In Sections 3.6 and 3.7 we derived a differential equation of continuity and a differential equation of
momentum transfer for a pure fluid. These equations were derived because overall mass, energy, and
momentum balances made on a finite volume in the earlier parts of Chapter 2 did not tell us what goes
on inside a control volume. In the overall balances performed, a new balance was made for each new
system studied. However, it is often easier to start with the differential equations of continuity and
momentum transfer in general form and then simplify the equations by discarding unneeded terms for
each specific problem.

In Chapter 4 on steady-state heat transfer and Chapter 5 on unsteady-state heat transfer, new overall
energy balances were made on a finite control volume for each new situation. To progress further in our
study of heat or energy transfer in flow and nonflow systems, we must use a differential volume to
investigate in greater detail what goes on inside this volume. The balance will be made on a single phase
and the boundary conditions at the phase boundary will be used for integration.

In the next section we derive a general differential equation of energy change: the conservation-of-energy
equation. Then this equation is modified for certain special cases that occur frequently. Finally,
applications of the uses of these equations are given. Cases for both steady-state and unsteady-state
energy transfer are studied using this conservation-of-energy equation, which is perfectly general and
holds for steady- or unsteady-state conditions.

5.6 B. De r iv ation of Diffe r e ntial Eq u ation of Ene r gy C hange

As in the derivation of the differential equation of momentum transfer, we write a balance on an element
of volume of size Δ×, Δy, Δz which is stationary. We then write the law of conservation of energy, which is
really the first law of thermodynamics for the fluid in this volume element at any time. The following is
the same as Eq. (2.7-7) for a control volume given in Section 2.7.

Equation 5.6-1

As in momentum transfer, the transfer of energy into and out of the volume element is by convection and
molecular transport or conduction. There are two kinds of energy being transferred. The first is internal
energy U in J/kg (btu/lbm) or any other set of units. This is the energy associated with random
translational and internal motions of the molecules plus molecular interactions. The second is kinetic
energy ρν2/2, which is the energy associated with the bulk fluid motion, where ν is the local fluid
velocity, m/s (ft/s). Hence, the total energy per unit volume is (ρU + ρν2/2). The rate of accumulation of
energy in the volume element in m3 (ft 3) is then

Equation 5.6-2

The total energy entering by convection in the x direction at x minus that leaving at x + Δx is

Equation 5.6-3

Similar equations can be written for the y and z directions using velocities νy  and νz, respectively.

The net rate of energy entering the element by conduction in the x direction is

Equation 5.6-4

Similar equations can be written for the y and z directions, where qx, qy , and qz are the components of the

heat flux vector q , which is in W/m2 (btu/s · ft 2) or any other convenient set of units.

The net work done by the system on its surroundings is the sum of the following three parts for the x
direction. For the net work done against the gravitational force,

Equation 5.6-5

where g x is gravitational force. The net work done against the static pressure p is

Equation 5.6-6

where p is N/m2 (lbf/ft 2) or any other convenient set of units. For the net work against the viscous forces,

Equation 5.6-7
In Section 3.7 these viscous forces are discussed in more detail.

Writing equations similar to (5.6-3)–(5.6-7) in all three directions; substituting these equations and Eq.
(5.6-2) into (5.6-1); dividing by Δx, Δy, and Δz; and letting Δx, Δy, and Δz approach zero, we obtain

Equation 5.6-8

[View full size image]

For further details of this derivation, see (B2).

Equation (5.6-8) is the final equation of energy change relative to a stationary point. However, it is not in
a convenient form. We first combine Eq. (5.6-8) with the equation of continuity, Eq. (3.6-23), with the
equation of motion, Eq. (3.7-13), and express the internal energy in terms of fluid temperature T and heat
capacity. Then writing the resultant equation for a Newtonian fluid with constant thermal conductivity
k, we obtain

Equation 5.6-9

This equation utilizes Fourier's second law in three directions, where

Equation 5.6-10

The viscous-dissipation term μφ is generally negligible except where extremely large velocity gradients
exist. It will be omitted in the discussions to follow. Equation (5.6-9) is the equation of energy change for
a Newtonian fluid with constant k in terms of the fluid temperature T.

5.6 C . S p e cial C ase s of the  Eq u ation of Ene r gy C hange


The following special forms of Eq. (5.6-9) for a Newtonian fluid with constant thermal conductivity are
commonly encountered. First, Eq. (5.6-9) will be written in rectangular coordinates without the μφ term:

Equation 5.6-11

1. Flu id  a t  const a nt  p r essu r e

The equations below can be used for constant-density fluids as well as for constant pressure.

Equation 5.6-12

In rectangular coordinates,

Equation 5.6-13

In cylindrical coordinates,

Equation 5.6-14

In spherical coordinates,

Equation 5.6-15

For definitions of cylindrical and spherical coordinates, see Section 3.6. If the velocity ν is zero, DT/Dt
becomes ∂T/∂t.
2. Flu id  a t  const a nt  d ensit y

Equation 5.6-16

Note that this is identical to Eq. (5.6-12) for constant pressure.

3. S olid

Here we consider ρ is constant and ν = 0.

Equation 5.6-17

This is often referred to as Fourier's second law of heat conduction. This also holds for a fluid with zero
velocity at constant pressure.

4 . Hea t  g ener a t ion

If there is heat generation in the fluid by electrical or chemical means, then   can be added to the right
side of Eq. (5.6-17).

Equation 5.6-18

where   is the rate of heat generation in W/m3 (btu/h · ft 3) or other suitable units. Viscous dissipation is


also a heat source, but its inclusion greatly complicates problem solving because the equations for energy
and motion are then coupled.

5. Ot her  coor d ina t e sy st ems

Fourier's second law of unsteady-state heat conduction can be written as follows.

For rectangular coordinates,

Equation 5.6-19
where α = k/pcp, thermal diffusivity in m2/s (ft 2/h).

For cylindrical coordinates,

Equation 5.6-20

For spherical coordinates,

Equation 5.6-21

5.6 D. Use s of Eq u ation of Ene r gy C hange

In Section 3.8 we used the differential equations of continuity and motion to set up fluid-flow problems.
We did this by discarding the terms that are zero or near zero and using the remaining equations to solve
for the velocity and pressure distributions. This was done instead of making new mass and momentum
balances for each new situation. In a similar manner, to solve problems of heat transfer, the differential
equations of continuity, motion, and energy will be used, with the unneeded terms being discarded.
Several examples will be given to illustrate the general methods used.

EXAMPLE 5.6-1. Temperature Profile with Heat Generation

A solid cylinder in which heat generation is occurring uniformly as   W/m3 is insulated on the
ends. The temperature of the surface of the cylinder is held constant at Tw  K. The radius of the
cylinder is r = R m. Heat flows only in the radial direction. Derive the equation for the
temperature profile at steady state if the solid has a constant thermal conductivity.

S olu t ion: Equation (5.6-20) will be used for cylindrical coordinates. The term  /ρcp for


generation will be added to the right side, giving

Equation 5.6-22

For steady state ∂T/∂t = 0. Also, for conduction only in the radial direction, ∂2T/∂z2 = 0 and
∂2T/∂θ2 = 0. This gives the following differential equation:
Equation 5.6-23

This can be rewritten as

Equation 5.6-24

Note that Eq. (5.6-24) can be rewritten as follows:

Equation 5.6-25

Integrating Eq. (5.6-25) once,

Equation 5.6-26

where K1 is a constant. Integrating again,

Equation 5.6-27

where K2 is a constant. The boundary conditions are when r = 0, dT/dr = 0 (by symmetry),
and when r = R, T = Tw . The final equation is

Equation 5.6-28

This is the same as Eq. (4.3-29), which was obtained by another method.
EXAMPLE 5.6-2. Laminar Flow and Heat Transfer Using
Equation of Energy Change
Using the differential equation of energy change, derive the partial differential equation and
boundary conditions needed for the case of laminar flow of a constant-density fluid in a
horizontal tube which is being heated. The fluid is flowing at a constant velocity νz. At the wall
of the pipe where the radius r = r 0, the heat flux is constant at q0. The process is at steady
state and it is assumed at z = 0 at the inlet that the velocity profile is established. Constant
physical properties will be assumed.

S olu t ion: From Example 3.8-3, the equation of continuity gives ∂νz/∂z = 0. Solution of the
equation of motion for steady state using cylindrical coordinates gives the parabolic velocity
profile:

Equation 5.6-29

Since the fluid has a constant density, Eq. (5.6-14) in cylindrical coordinates will be used for
the equation of energy change. For this case νr  = 0 and νθ = 0. Since this will be symmetrical,

∂T/∂θ and ∂2T/∂θ2 will be zero. For steady state, ∂T/∂t = 0. Hence, Eq. (5.6-14) reduces to

Equation 5.6-30

Usually conduction in the z direction (∂2T/∂z2 term) is small compared to the convective term
νz ∂T/∂z and can be dropped. Finally, substituting Eq. (5.6-29) into (5.6-30), we obtain

Equation 5.6-31

The boundary conditions are

For details on the actual solution of this equation, see Siegel et al. (S2).
                             
                                                 
                                             
                                               
     

5.7. BOUNDARY­LAYER FLOW AND TURBULENCE IN HEAT
TRANSFER

5.7A. Lam inar  Flow  and  Bou nd ar y-Laye r  The or y in He at Tr ansfe r

In Section 3.10C an exact solution was obtained for the velocity profile for isothermal laminar flow past a
flat plate. The solution of Blasius can be extended to include the convective heat-transfer problem for the
same geometry and laminar flow. In Fig. 5.7-1 the thermal boundary layer is shown. The temperature of
the fluid approaching the plate is T∞ and that of the plate is TS at the surface.

Figure 5.7-1. Laminar flow of fluid past a flat plate and thermal boundary layer.

We start by writing the differential energy balance, Eq. (5.6-13):

Equation 5.7-1

If the flow is in the x and y directions, νz = 0. At steady state, ∂T/∂t = 0. Conduction is neglected in the x

and z directions, so ∂2T/∂x2 = ∂2T/∂z2 = 0. Conduction occurs in the y direction. The result is

Equation 5.7-2
The simplified momentum-balance equation used in the velocity boundary-layer derivation is very
similar:

Equation 3.10-5

The continuity equation used previously is

Equation 3.10-3

Equations (3.10-5) and (3.10-3) were used by Blasius for solving the case for laminar boundary-layer
flow. The boundary conditions used were

Equation 5.7-3

The similarity between Eqs. (3.10-5) and (5.7-2) is obvious. Hence, the Blasius solution can be applied if
k/ρcp = μ/ρ. This means the Prandtl number cpμ/k = 1. Also, the boundary conditions must be the same.
This is done by replacing the temperature T in Eq. (5.7-2) by the dimensionless variable (T − TS)/(T∞ −
TS). The boundary conditions become

Equation 5.7-4
We see that the equations and boundary conditions are identical for the temperature profile and the
velocity profile. Hence, for any point x, y in the flow system, the dimensionless velocity variables νx/ν∞
and (T − TS)/(T∞ − TS) are equal. The velocity-profile solution is the same as the temperature-profile
solution.

This means that the transfer of momentum and heat are directly analogous, and the boundary-layer
thickness δ for the velocity profile (hydrodynamic boundary layer) and the thermal boundary-layer
thickness δT are equal. This is important for gases, where the Prandtl numbers are close to 1.

By combining Eqs. (3.10-7) and (3.10-8), the velocity gradient at the surface is

Equation 5.7-5

where NRe,x = xν∞ρ/μ. Also,

Equation 5.7-6

Combining Eqs. (5.7-5) and (5.7-6),

Equation 5.7-7

The convective equation can be related to the Fourier equation by the following, where qy  is in J/s or W
(btu/h):

Equation 5.7-8

Combining Eqs. (5.7-7) and (5.7-8),

Equation 5.7-9
where NNu,x is the dimensionless Nusselt number and hx is the local heat-transfer coefficient at point x
on the plate.

Pohlhausen (K1) was able to show that the relation between the hydrodynamic and thermal boundary
layers for fluids with Prandtl number >0.6 gives approximately

Equation 5.7-10

As a result, the equation for the local heat-transfer coefficient is

Equation 5.7-11

Also,

Equation 5.7-12

The equation for the mean heat-transfer coefficient h from x = 0 to x = L for a plate of width b and area bL
is

Equation 5.7-13

Integrating,

Equation 5.7-14

Equation 5.7-15
As pointed out previously, this laminar boundary layer on smooth plates holds up to a Reynolds number
of about 5 × 105. In using the results above, the fluid properties are usually evaluated at the film
temperature Tf = (TS + T∞)/2.

5.7B. Ap p r oxim ate  Inte gr al Analysis of the  The r m al Bou nd ar y Laye r

As discussed in the analysis of the hydrodynamic boundary layer, the Blasius solution is accurate but
limited in its scope. Other, more complex systems cannot be solved by this method. The approximate
integral analysis used by von Kármán to calculate the hydrodynamic boundary layer was covered in
Section 3.10. This approach can be used to analyze the thermal boundary layer.

This method will be outlined briefly. First, a control volume, as previously given in Fig. 3.10-5, is used to
derive the final energy integral expression:

Equation 5.7-16

This equation is analogous to Eq. (3.10-48) combined with Eq. (3.10-51) for the momentum analysis,
giving

Equation 5.7-17

Equation (5.7-16) can be solved if both a velocity profile and temperature profile are known. The assumed
velocity profile used is Eq. (3.10-50):

Equation 3.10-50

The same form of temperature profile is assumed:

Equation 5.7-18
Substituting Eqs. (3.10-50) and (5.7-18) into the integral expression and solving,

Equation 5.7-19

This is only about 8% greater than the exact result in Eq. (5.7-11), which indicates that this approximate
integral method can be used with confidence in cases where exact solutions cannot be obtained.

In a similar fashion, the integral momentum analysis method used for the turbulent hydrodynamic
boundary layer in Section 3.10 can be used for the thermal boundary layer in turbulent flow. Again, the

Blasius  -power law is used for the temperature distribution. These give results that are quite similar to
the experimental equations given in Section 4.6.

5.7C . Pr and tl M ixing Le ngth and  Ed d y The r m al Diffu siv ity

1. Ed d y  moment u m d iffu siv it y  in t u r b u lent  flow

In Section 3.10F the total shear stress   for turbulent flow was written as follows when the molecular
and turbulent contributions are summed together:

Equation 5.7-20

The molecular momentum diffusivity μ/ρ in m2/s is a function only of the fluid molecular properties.
However, the turbulent momentum eddy diffusivity εt depends on the fluid motion. In Eq. (3.10-29) we
related εt to the Prandtl mixing length L as follows:

Equation 3.10-29

2. Pr a nd t l mixing  leng t h a nd  ed d y  t her ma l d iffu siv it y

We can derive the eddy thermal diffusivity αt for turbulent heat transfer in a similar manner, as follows.
Eddies or clumps of fluid are transported a distance L in the y direction. At this point L the clump of
fluid differs in mean velocity from the adjacent fluid by the velocity  , which is the fluctuating velocity

component discussed in Section 3.10F. Energy is also transported the distance L with a velocity   in
the y direction together with the mass being transported. The instantaneous temperature of the fluid is 

 where   is the mean value and   the deviation from the mean value. This fluctuating

 is similar to the fluctuating velocity  . The mixing length is small enough that the temperature
difference can be written as

Equation 5.7-21

The rate of energy transported per unit area is qy /A and is equal to the mass flux in the y direction times
the heat capacity times the temperature difference:

Equation 5.7-22

In Section 3.10F we assumed   and that

Equation 5.7-23

Substituting Eq. (5.7-23) into (5.7-22),

Equation 5.7-24
According to Eq. (3.10-29) the term   is the momentum eddy diffusivity εt. When this term
is in the turbulent heat-transfer equation (5.7-24), it is called αt, eddy thermal diffusivity. Then Eq. (5.7-
24) becomes

Equation 5.7-25

Combining this with the Fourier equation written in terms of the molecular thermal diffusivity α,

Equation 5.7-26

3. S imila r it ies a mong  moment u m, hea t , a nd  ma ss t r a nsp or t

Equation (5.7-26) is similar to Eq. (5.7-20) for total momentum transport. The eddy thermal diffusivity
αt and the eddy momentum diffusivity εt have been assumed equal in the derivations. Experimental data
show that this equality is only approximate. An eddy mass diffusivity for mass transfer has been defined
in a similar manner using the Prandtl mixing length theory and is assumed equal to αt and εt.
                             
                                                 
                                             
                                               
     

PROBLEMS
5.2-1.
Temp er a t u r e R esp onse in C ooling  a  W ir e. A small copper wire with a diameter of 0.792
mm and initially at 366.5 K is suddenly immersed in a liquid held constant at 311 K. The
convection coefficient h = 85.2 W/m2 · K. The physical properties can be assumed constant and
are k = 374 W/m · K, cp = 0.389 kJ/kg · K, and ρ = 8890 kg/m3.

a.  Determine the time in seconds for the average temperature of the wire to drop to 338.8 K
(one-half the initial temperature difference).

b.  Do the same but for h = 11.36 W/m2 · K.

c.  For part (b), calculate the total amount of heat removed for a wire 1.0 m long.

A1:Ans. (a) t = 5.66 s
5.2-2.
Qu enchi ng  Lea d  S ho t  in a  Ba t h.  Lead shot having an average diameter of 5.1 mm is at an
initial temperature of 204.4°C. To quench the shot it is added to a quenching oil bath held at
32.2°C and falls to the bottom. The time of fall is 15 s. Assuming an average convection
coefficient of h = 199 W/m2 · K, what will be the temperature of the shot after the fall? For lead, ρ
= 11 370 kg/m3 and cp = 0.138 kJ/kg · K.
5.2-3.
Unst ea d y -S t a t e Hea t ing  of a  S t ir r ed  Ta nk . A vessel is filled with 0.0283 m3 of water
initially at 288.8 K. The vessel, which is well stirred, is suddenly immersed in a steam bath held
at 377.6 K. The overall heat-transfer coefficient U between the steam and water is 1136 W/m2 · K
and the area is 0.372 m2. Neglecting the heat capacity of the walls and agitator, calculate the
time in hours to heat the water to 338.7 K. [Hint: Since the water is well stirred, its temperature
is uniform. Show that Eq. (5.2-3) holds by starting with Eq. (5.2-1).]
5.3-1.
Temp er a t u r e in a  R efr a ct or y  Lining . A combustion chamber has a 2-in.-thick refractory
lining to protect the outer shell. To predict the thermal stresses at start-up, the temperature 0.2
in. below the surface is needed 1 min after start-up. The following data are available. The initial
temperature T0 = 100°F, the hot gas temperature T1 = 3000°F, h = 40 btu/h · ft 2 · °F, k = 0.6

btu/h · ft · °F, and α = 0.020 ft 2/h. Calculate the temperature at a 0.2-in. depth and a 0.6-in.
depth. Use Fig. 5.3-3 and justify its use by seeing if the lining acts as a semi-infinite solid during
this 1-min period.
A4 :Ans. For x = 0.2 in., (T − T0)/(T1 − T0) = 0.28 and T = 912°F (489°C); for x = 0.6 in., (T −
T0)/(T1 − T0) = 0.02 and T = 158°F (70°C)
5.3-2.
Fr eezing  Temp er a t u r e in t he  S oil. The average temperature of the soil to a considerable
depth is approximately 277.6 K (40°F) during a winter day. If the outside air temperature
suddenly drops to 255.4 K (0°F) and stays there, how long will it take for a pipe 3.05 m (10 ft)
below the surface to reach 273.2 K (32°F)? The convective coefficient is h = 8.52 W/m2 · K (1.5
btu/h · ft 2 · °F). The soil physical properties can be taken as 5.16 × 10−7  m2/s (0.02 ft 2/h) for the
thermal diffusivity and 1.384 W/m · K (0.8 btu/h · ft · °F) for the thermal conductivity. (Note:
The solution is trial and error, since the unknown time appears twice in the graph for a semi-
infinite solid.)
5.3-3.
C ooling  a  S la b  of Alu minu m. A large piece of aluminum that can be considered a semi-
infinite solid initially has a uniform temperature of 505.4 K. The surface is suddenly exposed to
an environment at 338.8 K with a surface convection coefficient of 455 W/m2 · K. Calculate the
time in hours for the temperature to reach 388.8 K at a depth of 25.4 mm. The average physical
properties are α = 0.340 m2/h and k = 208 W/m · K.
5.3-4 .
Tr a nsient  Hea t ing  of a  C oncr et e W a ll. A wall made of concrete 0.305 m thick is insulated
on the rear side. The wall at a uniform temperature of 10°C (283.2 K) is exposed on the front side
to a gas at 843°C (1116.2 K). The convection coefficient is 28.4 W/m2 · K, the thermal diffusivity
is 1.74 × 10−3 m2/h, and the thermal conductivity is 0.935 W/m · K.

a.  Calculate the time for the temperature at the insulated face to reach 232°C (505.2 K).

b.  Calculate the temperature at a point 0.152 m below the surface at this same time.

A7:  (a)  ,t =13.4 h

Ans.
5.3-5.
C ook ing  a  S la b  of M ea t . A slab of meat 25.4 mm thick originally at a uniform temperature of
10°C is to be cooked from both sides until the center reaches 121°C in an oven at 177°C. The
convection coefficient can be assumed constant at 25.6 W/m2 · K. Neglect any latent heat
changes and calculate the time required. The thermal conductivity is 0.69 W/m · K and the
thermal diffusivity 5.85 × 10−4 m2/h. Use the Heisler chart.
A8:Ans. 0.80 h (2880 s)
5.3-6 .
Unst ea d y -S t a t e C ond u ct ion in a  Br ick  W a ll. A flat brick wall 1.0 ft thick is the lining on
one side of a furnace. If the wall is at a uniform temperature of 100°F and one side is suddenly
exposed to a gas at 1100°F, calculate the time for the furnace wall at a point 0.5 ft from the
surface to reach 500°F. The rear side of the wall is insulated. The convection coefficient is 2.6
btu/h · ft 2 · °F and the physical properties of the brick are k = 0.65 btu/h · ft · °F and α = 0.02
ft 2/h.

5.3-7.
C ooling  a  S t eel R od . A long steel rod 0.305 m in diameter is initially at a temperature of 588
K. It is immersed in an oil bath maintained at 311 K. The surface convective coefficient is 125
W/m2 · K. Calculate the temperature at the center of the rod after 1 h. The average physical
properties of the steel are k = 38 W/m · K and α = 0.0381 m2/h.
A10:Ans. T = 391 K
5.3-8.
Effect  of S ize on Hea t  Pr ocessing  M ea t . An autoclave held at 121.1°C is being used to
process sausage meat 101.6 mm in diameter and 0.61 m long which is originally at 21.1°C. After
2 h the temperature at the center is 98.9°C. If the diameter is increased to 139.7 mm, how long
will it take for the center to reach 98.9°C? The heat-transfer coefficient to the surface is h = 1100
W/m2 · K, which is very large, so the surface resistance can be considered negligible. (Show this.)
Neglect the heat transfer from the ends of the cylinder. The thermal conductivity k = 0.485 W/m
· K.
A11:Ans. 3.78 h
5.3-9 .
Temp er a t u r e of Or a ng es on Tr ees Du r ing  Fr eezing  W ea t her . In orange-growing areas,
the freezing of the oranges on the trees during cold nights is of serious economic concern. If the
oranges are initially at a temperature of 21.1°C, calculate the center temperature of the orange if
exposed to air at −3.9°C for 6 h. The oranges are 102 mm in diameter and the convective
coefficient is estimated as 11.4 W/m2 · K. The thermal conductivity k is 0.431 W/m · K and α is
4.65 × 10−4 m2/h. Neglect any latent heat effects.
A12:Ans. (T1 − T)/(T1 − T0) = 0.05, T = −2.65°C
5.3-10.
Ha r d ening  a  S t eel S p her e. To harden a steel sphere having a diameter of 50.8 mm, it is
heated to 1033 K and then dunked into a large water bath at 300 K. Determine the time for the
center of the sphere to reach 366.5 K. The surface coefficient can be assumed as 710 W/m2 · K, k
= 45 W/m · K, and α = 0.0325 m2/h.
5.3-11.
Unst ea d y -S t a t e C ond u ct ion in a  S hor t  C y lind er . An aluminum cylinder is initially
heated to a uniform temperature of 204.4°C. Then it is plunged into a large bath held at 93.3°C,
where h = 568 W/m2 · K. The cylinder has a diameter of 50.8 mm and is 101.6 mm long.
Calculate the center temperature after 60 s. The physical properties are α = 9.44 × 10−5 m2/s
and k = 207.7 W/m · K.
5.3-12.
C ond u ct ion in Thr ee Dimensions in a  R ect a ng u la r  Block . A rectangular steel block
0.305 m by 0.457 m by 0.61 m is initially at 315.6°C. It is suddenly immersed in an environment
at 93.3°C. Determine the temperature at the center of the block after 1 h. The surface convection
coefficient is 34 W/m2 · K. The physical properties are k = 38 W/m · K and α = 0.0379 m2/h.

5.4 -1.
S chmid t  Nu mer ica l M et hod  for  Unst ea d y -S t a t e C ond u ct ion. A material in the form of
an infinite plate 0.762 m thick is at an initial uniform temperature of 366.53 K. The rear face of
the plate is insulated. The front face is suddenly exposed to a temperature of 533.2 K. The
convective resistance at this face can be assumed as zero. Calculate the temperature profile after
0.875 h using the Schmidt numerical method with M = 2 and slabs 0.1524 m thick. The thermal
diffusivity is 0.0929 m2/h.
A16 :Ans. Δt = 0.125 h, seven time increments needed
5.4 -2.
Unst ea d y -S t a t e C ond u ct ion w it h Nonu nifor m Init ia l Temp er a t u r e Pr ofile. Use the
same conditions as in Problem 5.4-1 but with the following change. The initial temperature
profile is not uniform but is 366.53 K at the front face and 422.1 K at the rear face with a linear
variation between the two faces.
5.4 -3.
Unst ea d y -S t a t e C ond u ct ion Using  t he Dig it a l C omp u t er . Repeat Problem 5.4-2 but use
the computer and a spreadsheet. Use slabs 0.03048 m thick and M = 2.0. Calculate the
temperature profile after 0.875 h.
5.4 -4 .
C hilling  M ea t  Using  Nu mer ica l M et hod s. A slab of beef 45.7 mm thick and initially at a
uniform temperature of 283 K is being chilled by a surface contact cooler at 274.7 K on the front
face. The rear face of the meat is insulated. Assume that the convection resistance at the front
surface is zero. Using five slices and M = 2, calculate the temperature profile after 0.54 h. The
thermal diffusivity is 4.64 × 10−4 m2/h.
A19 :Ans. Δt = 0.090 h, six time increments
5.4 -5.
C ooling  Beef w it h C onv ect iv e R esist a nce. A large slab of beef is 45.7 mm thick and is at an
initial uniform temperature of 37.78°C. It is being chilled at the front surface in a chilled air blast
at −1.11°C with a convective heat-transfer coefficient of h = 38.0 W/m2 · K. The rear face of the
meat is insulated. The thermal conductivity of the beef is k = 0.498 W/m · K and α = 4.64 ×
10−4 m2/h. Using a numerical method with five slices and M = 4.0, calculate the temperature
profile after 0.27 h. [Hint: Since there is a convective resistance, the value of N must be
calculated. Also, Eq. (5.4-7) should be used.]
A20:Ans. 17.16°C (n = 1), 28.22°C (2), 34.48°C (3), 37.00°C (4), 37.67°C (5), 37.77°C (6)
5.4 -6 .
C ooling  Beef Using  t he Dig it a l C omp u t er . Repeat Problem 5.4-5 using the digital
computer. Use 20 slices and M = 4.0. Use a spreadsheet calculation.
5.4 -7.
C onv ect ion a nd  Unst ea d y -S t a t e C ond u ct ion. For the conditions of Example 5.4-3,
continue the calculations for a total of 12 time increments. Plot the temperature profile.

5.4 -8.
Alt er na t iv e C onv ect iv e Bou nd a r y  C ond it ion for  Nu mer ica l M et hod . Repeat Example
5.4-3 but instead use the alternative boundary condition, Eq. (5.4-11). Also, use M = 4.
Calculate the profile for the full 12 time increments.
5.4 -9 .
Nu mer ica l M et hod  for  S emi-infinit e S olid  a nd  C onv ect ion. A semi-infinite solid
initially at a uniform temperature of 200°C is cooled at its surface by convection. The cooling
fluid at a constant temperature of 100°C has a convective coefficient of h = 250 W/m2 · K. The
physical properties of the solid are k = 20 W/m · K and α = 4 × 10−5 m2/s. Using a numerical
method with Δx = 0.040 m and M = 4.0, calculate the temperature profile after 50 s total time.
A24 :Ans. T1 = 157.72, T2 = 181.84, T3 = 194.44, T4 = 198.93, T5 = 199.90°C
5.5-1.
C hilling  S la b  of Beef. Repeat Example 5.5-1, where the slab of beef is cooled to 10°C at the
center, but use air of 0°C at a lower value of h = 22.7 W/m2 · K.
A25:Ans. (T1 − T)/(T1 − T0) = 0.265, X = 0.92, t = 19.74 h
5.5-2.
C hilling  Fish Fillet s. Codfish fillets originally at 10°C are packed to a thickness of 102 mm.
Ice is packed on both sides of the fillets and wet-strength paper separates the ice and fillets. The
surface temperature of the fish can be assumed as essentially 0°C. Calculate the time for the
center of the fillets to reach 2.22°C and the temperature at this time at a distance of 25.4 mm
from the surface. Also, plot temperature versus position for the slab. The physical properties are
(B1) k = 0.571 W/m · K, ρ = 1052 kg/m3, and cp = 4.02 kJ/kg · K.
5.5-3.
Av er a g e Temp er a t u r e in C hilling  Fish. Fish fillets having the same physical properties
given in Problem 5.5-2 are originally at 10°C. They are packed to a thickness of 102 mm with ice
on each side. Assuming that the surface temperature of the fillets is 0°C, calculate the time for
the average temperature to reach 1.39°C. (Note: This is a case where the surface resistance is
zero. Can Fig. 5.3-13 be used for this case?)
5.5-4 .
Time t o Fr eeze a  S la b  of M ea t . Repeat Example 5.5-2 using the same conditions except that
a plate or contact freezer is used where the surface coefficient can be assumed as h = 142 W/m2 ·
K.
A28:Ans. t = 2.00 h
5.5-5.
Fr eezing  a  C y lind er  of M ea t . A package of meat containing 75% moisture and in the form of
a long cylinder 5 in. in diameter is to be frozen in an air-blast freezer at −25°F. The meat is
initially at the freezing temperature of 27°F. The heat-transfer coefficient is h = 3.5 btu/h · ft 2 ·
°F. The physical properties are ρ = 64 lbm/ft 3 for the unfrozen meat and k = 0.60 btu/h · ft · °F
for the frozen meat. Calculate the freezing time.
5.6 -1.
Hea t  G ener a t ion Using  Eq u a t ion of Ener g y  C ha ng e. A plane wall with uniform internal

heat generation of   W/m3 is insulated at four surfaces, with heat conduction only in the x
direction. The wall has a thickness of 2L m. The temperature at one wall at x = +L and at the
other wall at x = −L is held constant at Tw  K. Using the differential equation of energy change,
Eq. (5.6-18), derive the equation for the final temperature profile.

A30:  

Ans.
5.6 -2.
Hea t  Tr a nsfer  in a  S olid  Using  Eq u a t ion of Ener g y  C ha ng e. A solid of thickness L is at
a uniform temperature of T0 K. Suddenly the front surface temperature of the solid at z = 0 m is
raised to T1 at t = 0 and held there, and at z = L at the rear to T2 and held constant. Heat transfer
occurs only in the z direction. For constant physical properties and using the differential
equation of energy change, do as follows:

a.  Derive the partial differential equation and the boundary conditions (B.C.) for unsteady-
state energy transfer.

b.  Do the same for steady state and integrate the final equation.

A31: Ans.  (a) ∂T/∂t  = α ∂2T/∂z2; B.C.(1): t  = 0, z = z, T = T ; B.C.(2): t  = t, z = 0, T = T ; B.C.(3): t  =


0 1
t, z = L, T = T2; (b) T = (T2 − T1)z/L + T1
5.6 -3.
R a d ia l Temp er a t u r e Pr ofile Using  t he Eq u a t ion of Ener g y  C ha ng e. Radial heat
transfer is occurring by conduction through a long, hollow cylinder of length L with the ends
insulated.

a.  What is the final differential equation for steady-state conduction? Start with Fourier's
second law in cylindrical coordinates, Eq. (5.6-20).

b.  Solve the equation for the temperature profile from part (a) for the boundary conditions
given as follows: T = Ti for r = r i, T = To for r = r o.

c.  Using part (b), derive an expression for the heat flow q in W.

A32:
 

Ans.
5.6 -4 .
Hea t  C ond u ct ion in a  S p her e. Radial energy flow is occurring in a hollow sphere with an
inside radius of r i and an outside radius of r o. At steady state the inside surface temperature is
constant at Ti and constant at To on the outside surface.

a.  Using the differential equation of energy change, solve the equation for the temperature
profile.

b.  Using part (a), derive an expression for the heat flow in W.

5.6 -5.
Va r ia b le Hea t  G ener a t ion a nd  Eq u a t ion of Ener g y  C ha ng e. A plane wall is insulated
so that conduction occurs only in the x direction. The boundary conditions which apply at
steady state are T = T0 at x = 0 and T = TL at x = L. Internal heat generation per unit volume is

occurring and varies as  , where   and ß are constants. Solve the general


differential equation of energy change for the temperature profile.
5.7-1.
Ther ma l a nd  Hy d r od y na mic Bou nd a r y  La y er  Thick nesses. Air at 294.3 K and 101.3
kPa with a free stream velocity of 12.2 m/s is flowing parallel to a smooth, flat plate held at a
surface temperature of 383 K. Do the following:

a.  At the critical NRe,L = 5 × 105, calculate the critical length x = L of the plate, the thickness
δ of the hydrodynamic boundary layer, and the thickness δT of the thermal boundary
layer. Note that the Prandtl number is not 1.0.

b.  Calculate the average heat-transfer coefficient over the plate covered by the laminar
boundary layer.

5.7-2.
Bou nd a r y -La y er  Thick nesses a nd  Hea t  Tr a nsfer . Air at 37.8°C and 1 atm abs flows at a
velocity of 3.05 m/s parallel to a flat plate held at 93.3°C. The plate is 1 m wide. Calculate the
following at a position 0.61 m from the leading edge:

a.  The thermal boundary-layer thickness δT and the hydrodynamic boundary-layer
thickness δ.

b.  Total heat transfer from the plate.
                             
                                                 
                                             
                                               
     

Chapter 6. Principles of Mass Transfer
                             
                                                 
                                             
                                               
     

6.1. INTRODUCTION TO MASS TRANSFER AND DIFFUSION

6 .1A. S im ilar ity of M ass, He at, and  M om e ntu m  Tr ansfe r  Pr oce sse s

1. Int r od u ct ion

In Chapter 1 we noted that the various separation processes have certain basic principles which can be
classified into three fundamental transfer (or “transport”) processes: momentum transfer, heat transfer,
and mass transfer. The fundamental process of momentum transfer occurs in such operations as fluid
flow, mixing, sedimentation, and filtration. Heat transfer occurs in conductive and convective transfer
of heat, evaporation, distillation, and drying.

The third fundamental transfer process, mass transfer, occurs in distillation, absorption, drying, liquid–
liquid extraction, adsorption, ion exchange, crystallization, and membrane processes. When mass is
being transferred from one distinct phase to another or through a single phase, the basic mechanisms are
the same whether the phase is a gas, liquid, or solid. This was also shown for heat transfer, where the
transfer of heat by conduction followed Fourier's law in a gas, solid, or liquid.

2. G ener a l molecu la r  t r a nsp or t  eq u a t ion

All three of the molecular transport processes—momentum, heat, and mass—are characterized by the
same general type of equation, given in Section 2.3A:

Equation 2.3-1

This can be written as follows for molecular diffusion of the property momentum, heat, or mass:

Equation 2.3-2

3. M olecu la r  d iffu sion eq u a t ions for  moment u m, he a t , a nd  ma ss t r a nsfer

Newton's equation for momentum transfer for constant density can be written as follows in a manner
similar to Eq. (2.3-2):

Equation 6.1-1
where τzx is momentum transferred/s · m2, μ/ρ is kinematic viscosity in m2/s, z is distance in m, and vx

ρ is momentum/m3, where the momentum has units of kg · m/s.

Fourier's law for heat conduction can be written as follows for constant ρ and cp:

Equation 6.1-2

where qz/A is heat flux in W/m2, α is the thermal diffusivity in m2/s, and ρcp T is J/m3.

The equation for molecular diffusion of mass is Fick's law and is also similar to Eq. (2.3-2). It is written
as follows for constant total concentration in a fluid:

Equation 6.1-3

where   is the molar flux of component A in the z direction due to molecular diffusion in kg · mol A/s ·
m2, DAB the molecular diffusivity of the molecule A in B in m2/s, cA the concentration of A in kg ·

mol/m3, and z the distance of diffusion in m. In cgs units   is g mol A/s · cm2, DAB is cm2/s, and cA is

g mol A/cm3. In English units,   is lb mol/h · ft 2, DAB is ft 2/h, and cA is lb mol/ft 3.

The similarity of Eqs. (6.1-1), (6.1-2), and (6.1-3) for momentum, heat, and mass transfer should be
obvious. All the fluxes on the left-hand side of the three equations have as units transfer of a quantity of
momentum, heat, or mass per unit time per unit area. The transport properties μ/ρ, α and DAB all have

units of m2/s, and the concentrations are represented as momentum/m3, J/m3, or kg mol/m3.

4 . Tu r b u lent  d iffu sion eq u a t ions for  moment u m, hea t , a nd  ma ss t r a nsfer

In Section 5.7C equations were given showing the similarities among momentum, heat, and mass
transfer in turbulent transfer. For turbulent momentum transfer and constant density,

Equation 6.1-4
For turbulent heat transfer for constant ρ and cp,

Equation 6.1-5

For turbulent mass transfer for constant c,

Equation 6.1-6

In these equations εt is the turbulent or eddy momentum diffusivity in m2/s, αt the turbulent or eddy

thermal diffusivity in m2/s, and εM the turbulent or eddy mass diffusivity in m2/s. Again, these
equations are quite similar to each other. Many of the theoretical equations and empirical correlations for
turbulent transport to various geometries are also quite similar.

6 .1B. Exam p le s of M ass-Tr ansfe r  Pr oce sse s

Mass transfer is important in many areas of science and engineering. Mass transfer occurs when a
component in a mixture migrates in the same phase or from phase to phase because of a difference in
concentration between two points. Many familiar phenomena involve mass transfer. Liquid in an open
pail of water evaporates into still air because of the difference in concentration of water vapor at the water
surface and the surrounding air. There is a “driving force” from the surface to the air. A piece of sugar
added to a cup of coffee eventually dissolves by itself and diffuses to the surrounding solution. When
newly cut and moist green timber is exposed to the atmosphere, the wood will dry partially when water
in the timber diffuses through the wood to the surface and then to the atmosphere. In a fermentation
process nutrients and oxygen dissolved in the solution diffuse to the microorganisms. In a catalytic
reaction the reactants diffuse from the surrounding medium to the catalyst surface, where reaction
occurs.

Many purification processes involve mass transfer. In uranium processing, a uranium salt in solution is
extracted by an organic solvent. Distillation to separate alcohol from water involves mass transfer.
Removal of SO2 from flue gas is done by absorption in a basic liquid solution.

We can treat mass transfer in a manner somewhat similar to that used in heat transfer with Fourier's law
of conduction. However, an important difference is that in molecular mass transfer, one or more of the
components of the medium is moving. In heat transfer by conduction, the medium is usually stationary
and only energy in the form of heat is being transported. This introduces some differences between heat
and mass transfer that will be discussed in this chapter.
6 .1C . Fick's Law  for  M ole cu lar  Diffu sion

Molecular diffusion or molecular transport can be defined as the transfer or movement of individual
molecules through a fluid by means of the random, individual movements of the molecules. We can
imagine the molecules traveling only in straight lines and changing direction by bouncing off other
molecules after collision. Since the molecules travel in a random path, molecular diffusion is often called
a random-walk process.

In Fig. 6.1-1 the molecular diffusion process is shown schematically. A random path that molecule A
might take in diffusing through B molecules from point (1) to (2) is shown.If there are a greater number of
A molecules near point (1) than at (2), then, since molecules diffuse randomly in both directions, more A
molecules will diffuse from (1) to (2) than from (2) to (1). The net diffusion of A is from high- to low-
concentration regions.

Figure 6.1-1. Schematic diagram of molecular diffusion process.

As another example, a drop of blue liquid dye is added to a cup of water. The dye molecules will diffuse
slowly by molecular diffusion to all parts of the water. To increase this rate of mixing of the dye, the
liquid can be mechanically agitated by a spoon and convective mass transfer will occur. The two modes
of heat transfer, conduction and convective heat transfer, are analogous to molecular diffusion and
convective mass transfer.

First, we will consider the diffusion of molecules when the whole bulk fluid is not moving but is
stationary. Diffusion of the molecules is due to a concentration gradient. The general Fick's law equation
can be written as follows for a binary mixture of A and B:

Equation 6.1-7

where c is total concentration of A and B in kg mol A + B/m3, and xA is the mole fraction of A in the
mixture of A and B. If c is constant, then since cA = cxA,

Equation 6.1-8
Substituting into Eq. (6.1-7) we obtain Eq. (6.1-3) for constant total concentration:

Equation 6.1-3

This equation is the one more commonly used in many molecular diffusion processes. If c varies some, an
average value is often used with Eq. (6.1-3).

EXAMPLE 6.1-1. Molecular Diffusion of Helium in Nitrogen
A mixture of He and N2 gas is contained in a pipe at 298 K and 1 atm total pressure which is
constant throughout. At one end of the pipe at point 1 the partial pressure pA1 of He is 0.60
atm and at the other end 0.2 m (20 cm) pA2 = 0.20 atm. Calculate the flux of He at steady

state if DAB of the He–N2 mixture is 0.687 × 10−4 m2/s (0.687 cm2/s). Use SI and cgs units.

S olu t ion: Since total pressure P is constant, then c is constant, where c is as follows for a gas
according to the perfect gas law:

Equation 6.1-9

Equation 6.1-10

where n is kg · mol A plus B, V is volume in m3, T is temperature in K, R is 8314.3 m3 · Pa/kg ·
mol · K or R is 82.057 × 10−3 m3 · atm/kg mol · K, and c is kg mol A plus B/m3. In cgs units, R
is 82.057 cm3 · atm/g mol · K.

For steady state the flux   in Eq. (6.1-3) is constant. Also, DAB for a gas is constant.
Rearranging Eq. (6.1-3) and integrating,

Equation 6.1-11
Also, from the perfect gas law, pAV = nART, and

Equation 6.1-12

Substituting Eq. (6.1-12) into (6.1-11),

Equation 6.1-13

This is the final equation to use, which is in a form easily used for gases. Partial pressures are
pA1 = 0.6 atm = 0.6 × 1.01325 × 105 = 6.08 × 104 Pa and pA2 = 0.2 atm = 0.2 × 1.01325 × 105

= 2.027 × 104 Pa. Then, using SI units,

If pressures in atm are used with SI units,

For cgs units, substituting into Eq. (6.1-13),

Other driving forces (besides concentration differences) for diffusion also occur because of temperature,
pressure, electrical potential, and other gradients. Details are given elsewhere (B3).
6 .1D. C onv e ctiv e  M ass-Tr ansfe r  C oe fficie nt

When a fluid is flowing outside a solid surface in forced convection motion, we can express the rate of
convective mass transfer from the surface to the fluid, or vice versa, by the following equation:

Equation 6.1-14

where kc is a mass-transfer coefficient in m/s, cL1 the bulk fluid concentration in kg mol A/m3, and cLi
the concentration in the fluid next to the surface of the solid. This mass-transfer coefficient is very similar
to the heat-transfer coefficient h and is a function of the system geometry, fluid properties, and flow
velocity. In Chapter 7 we consider convective mass transfer in detail.
                             
                                                 
                                             
                                               
     

6.2. MOLECULAR DIFFUSION IN GASES

6 .2A. Eq u im olar  C ou nte r d iffu sion in G ase s

In Fig. 6.2-1 a diagram is given of two gases A and B at constant total pressure P in two large chambers
connected by a tube where molecular diffusion at steady state is occurring. Stirring in each chamber
keeps the concentrations in each chamber uniform. The partial pressure pA1 > pA2 and pB2 > pB1.
Molecules of A diffuse to the right and B to the left. Since the total pressure P is constant throughout, the
net moles of A diffusing to the right must equal the net moles of B to the left. If this is not so, the total
pressure would not remain constant. This means that

Equation 6.2-1

Figure 6.2-1. Equimolar counterdiffu sion of gases A and B.

The subscript z is often dropped when the direction is obvious. Writing Fick's law for B for constant c,

Equation 6.2-2

Now since P = pA + pB = constant, then
Equation 6.2-3

Differentiating both sides,

Equation 6.2-4

Equating Eq. (6.1-3) to (6.2-2),

Equation 6.2-5

Substituting Eq. (6.2-4) into (6.2-5) and canceling like terms,

Equation 6.2-6

This shows that for a binary gas mixture of A and B, the diffusivity coefficient DAB for A diffusing into B
is the same as DBA for B diffusing into A.

EXAMPLE 6.2-1. Equimolar Counterdiffusion
Ammonia gas (A) is diffusing through a uniform tube 0.10 m long containing N2 gas (B) at

1.0132 × 105 Pa pressure and 298 K. The diagram is similar to Fig. 6.2-1. At point 1, pA1 =

1.013 × 104 Pa and at point 2, pA2 = 0.507 × 104 Pa. The diffusivity DAB = 0.230 × 10−4 m2/s.

a.  Calculate the flux   at steady state.

b.  Repeat for 

S olu t ion: Equation (6.1-13) can be used, where P = 1.0132 × 105 Pa, z2 − z1 = 0.10 m, and T =
298 K. Substituting into Eq. (6.1-13) for part (a),
Rewriting Eq. (6.1-13) for component B for part (b) and noting that pB1 = P − pA1 = 1.0132 ×

105 − 1.013 × 104 = 9.119 × 104 Pa and pB2 = P − pA2 = 1.0132 × 105 − 0.507 × 104 = 9.625 ×

104 Pa,

The negative value for   means the flux goes from point 2 to point 1.

6 .2B. G e ne r al C ase  for  Diffu sion of G ase s A and  B Plu s C onv e ction

Up to now we have considered Fick's law for diffusion in a stationary fluid; that is, there has been no net

movement or convective flow of the entire phase of the binary mixture A and B. The diffusion flux 
occurred because of the concentration gradient. The rate at which moles of A passed a fixed point to the

right, which will be taken as a positive flux, is   kg mol A/s · m2. This flux can be converted to a
velocity of diffusion of A to the right by

Equation 6.2-7

where νAd is the diffusion velocity of A in m/s.

Now let us consider what happens when the whole fluid is moving in bulk or convective flow to the right.
The molar average velocity of the whole fluid relative to a stationary point is νM m/s. Component A is
still diffusing to the right, but now its diffusion velocity νAd is measured relative to the moving fluid. To a
stationary observer A is moving faster than the bulk of the phase, since its diffusion velocity νAd is added
to that of the bulk phase νM. Expressed mathematically, the velocity of A relative to the stationary point
is the sum of the diffusion velocity and the average or convective velocity:

Equation 6.2-8

where νA is the velocity of A relative to a stationary point. Expressed pictorially,
Multiplying Eq. (6.2-8) by cA,

Equation 6.2-9

Each of the three terms represents a flux. The first term, cAνA, can be represented by the flux NA kg mol

A/s · m2. This is the total flux of A relative to the stationary point. The second term is  , the diffusion
flux relative to the moving fluid. The third term is the convective flux of A relative to the stationary point.
Hence, Eq. (6.2-9) becomes

Equation 6.2-10

Let N be the total convective flux of the whole stream relative to the stationary point. Then,

Equation 6.2-11

Or, solving for vM,

Equation 6.2-12

Substituting Eq. (6.2-12) into (6.2-10),

Equation 6.2-13

Since   is Fick's law, Eq. (6.1-7),

Equation 6.2-14
Equation (6.2-14) is the final general equation for diffusion plus convection to use when the flux NA is
used, which is relative to a stationary point. A similar equation can be written for NB.

Equation 6.2-15

To solve Eq. (6.2-14) or (6.2-15), the relation between the flux NA and NB must be known. Equations
(6.2-14) and (6.2-15) hold for diffusion in a gas, liquid, or solid.

For equimolar counterdiffusion, NA = −NB and the convective term in Eq. (6.2-14) becomes zero. Then,

NA =   = −NB =× .

6 .2C . S p e cial C ase  for  A Diffu sing Thr ou gh S tagnant, Nond iffu sing B

The case of diffusion of A through stagnant or nondiffusing B at steady state often occurs. In this case
one boundary at the end of the diffusion path is impermeable to component B, so it cannot pass through.
One example, shown in Fig. 6.2-2a, is in the evaporation of a pure liquid such as benzene (A) at the
bottom of a narrow tube, where a large amount of inert or nondiffusing air (B) is passed over the top. The
benzene vapor (A) diffuses through the air (B) in the tube. The boundary at the liquid surface at point 1 is
impermeable to air, since air is insoluble in benzene liquid. Hence, air (B) cannot diffuse into or away
from the surface. At point 2 the partial pressure pA2 = 0, since a large volume of air is passing by.

Figure 6.2-2. Diffusion of A through stagnant, nondiffusing B: (a) benzene evaporating into air, (b) ammonia in
air being absorbed into water.

Another example, shown in Fig. 6.2-2b, occurs in the absorption of NH3 (A) vapor which is in air (B) by
water. The water surface is impermeable to the air, since air is only very slightly soluble in water. Thus,
since B cannot diffuse, NB = 0.

To derive the case for A diffusing in stagnant, nondiffusing B, NB = 0 is substituted into the general Eq.
(6.2-14):

Equation 6.2-16

The convective flux of A is (cA/c)(NA + 0). Keeping the total pressure P constant, substituting c = P/RT,
pA = xAP, and cA/c = pA/P into Eq. (6.2-16),

Equation 6.2-17

Rearranging and integrating,

Equation 6.2-18

Equation 6.2-19

Equation 6.2-20

Equation (6.2-20) is the final equation to be used to calculate the flux of A. However, it is often written in
another form. A log mean value of the inert B is defined as follows. Since P = pA1 + pB1 = pA2 + pB2, pB1 =
P − pA1, and pB2 = P − pA2,

Equation 6.2-21
Substituting Eq. (6.2-21) into (6.2-20),

Equation 6.2-22

EXAMPLE 6.2-2. Diffusion of Water Through Stagnant,
Nondiffusing Air
Water in the bottom of a narrow metal tube is held at a constant temperature of 293 K. The
total pressure of air (assumed dry) is 1.01325 × 105 Pa (1.0 atm) and the temperature is 293 K
(20°C). Water evaporates and diffuses through the air in the tube, and the diffusion path z2 −
z1 is 0.1524 m (0.5 ft) long. The diagram is similar to Fig. 6.2-2a. Calculate the rate of

evaporation at steady state in lb mol/h · ft 2 and kg mol/s · m2. The diffusivity of water vapor
at 293 K and 1 atm pressure is 0.250 × 10−4 m2/s. Assume that the system is isothermal. Use
SI and English units.

S olu t ion: The diffusivity is converted to ft 2/h by using the conversion factor from Appendix


A.1:

From Appendix A.2 the vapor pressure of water at 20°C is 17.54 mm, or pA1 = 17.54/760 =

0.0231 atm = 0.0231(1.01325 × 105) = 2.341 × 103 Pa, pA2 = 0 (pure air). Since the

temperature is 20°C (68°F), T = 460 + 68 = 528°R = 293 K. From Appendix A.1, R = 0.730 ft 3
· atm/lb · mol·°R. To calculate the value of pBM from Eq. (6.2-21),

Since pB1 is close to pB2, the linear mean (pB1 + pB2)/2 could be used and would be very close
to pBM.

Substituting into Eq. (6.2-22) with z2 − z1 = 0.5 ft (0.1524 m),
EXAMPLE 6.2-3. Diffusion in a Tube with Change in Path
Length
Diffusion of water vapor in a narrow tube is occurring as in Example 6.2-2 under the same
conditions. However, as shown in Fig. 6.2-2a, at a given time t, the level is z m from the top.
As diffusion proceeds, the level drops slowly. Derive the equation for the time t F for the level to
drop from a starting point of z0 m at t = 0 to zF at t = t F s as shown.

S olu t ion: We assume a pseudo-steady-state condition since the level drops very slowly. As
time progresses, the path length z increases. At any time t, Eq. (6.2-22) holds; but the path
length is z and Eq. (6.2-22) becomes as follows, where NA and z are now variables:

Equation 6.2-23

Assuming a cross-sectional area of 1 m2, the level drops dz m in dt s, and ρA(dz · 1)/MA is the
kg mol of A that have left and diffused. Then,

Equation 6.2-24

Equating Eq. (6.2-24) to (6.2-23), rearranging, and integrating between the limits of z = z0
when t = 0 and z = zF when t = t F,

Equation 6.2-25

Solving for t F,
Equation 6.2-26

The method shown in Example 6.2-3 has been used to experimentally determine the diffusivity DAB. In
this experiment the starting path length z0 is measured at t = 0 together with the final zF at t F. Then Eq.
(6.2-26) is used to calculate DAB.

6 .2D. Diffu sion Thr ou gh a Var ying C r oss-S e ctional Ar e a

So far, in the cases at steady state we have considered NA and   as constants in the integrations. In

these cases the cross-sectional area A m2 through which the diffusion occurs has been constant with
varying distance z. In some situations the area A may vary. Then it is convenient to define NA as

Equation 6.2-27

where   is kg moles of A diffusing per second or kg mol/s. At steady state,   will be constant but not


A for a varying area.

1. Diffu sion fr om a  sp her e

To illustrate the use of Eq. (6.2-27), the important case of diffusion to or from a sphere in a gas will be
considered. This situation appears often, in such cases as the evaporation of a drop of liquid, the
evaporation of a ball of naphthalene, and the diffusion of nutrients to a sphere-like microorganism in a
liquid. In Fig. 6.2-3a is shown a sphere of fixed radius r 1 m in an infinite gas medium. Component (A) at
partial pressure pA1 at the surface is diffusing into the surrounding stagnant medium (B), where pA2 = 0
at some large distance away. Steady-state diffusion will be assumed.

Figure 6.2-3. Diffusion through a varying cross-sectional area: (a) from a sphere to a surrounding medium, (b)
through a circular conduit that is tapered uniformally.
The flux NA can be represented by Eq. (6.2-27), where A is the cross-sectional area 4πr 2 at point r

distance from the center of the sphere. Also,   is a constant at steady state:

Equation 6.2-28

Since this is a case of A diffusing through stagnant, nondiffusing B, Eq. (6.2-18) will be used in its
differential form and NA will be equated to Eq. (6.2-28), giving

Equation 6.2-29

Note that dr was substituted for dz. Rearranging and integrating between r 1 and some point r 2 a large


distance away,

Equation 6.2-30

Equation 6.2-31

Since  , 1/r 2 ≅ 0. Substituting pBM from Eq. (6.2-21) into Eq. (6.2-31),


Equation 6.2-32

This equation can be simplified further. If pA1 is small compared to P (a dilute gas phase),PBM ≅ P . Also,
setting 2r 1 = D1, diameter, and cA1 = pA1/RT, we obtain

Equation 6.2-33

This equation can also be used for liquids, where DAB is the diffusivity of A in the liquid.

EXAMPLE 6.2-4. Evaporation of a Naphthalene Sphere
A sphere of naphthalene having a radius of 2.0 mm is suspended in a large volume of still air
at 318 K and 1.01325 × 105 Pa (1 atm). The surface temperature of the naphthalene can be
assumed to be at 318 K and its vapor pressure at 318 K is 0.555 mm Hg. The DAB of

naphthalene in air at 318 K is 6.92 × 10−6 m2/s. Calculate the rate of evaporation of
naphthalene from the surface.

S olu t ion: The flow diagram is similar to Fig. 6.2-3a. DAB = 6.92 × 10−6 m2/s, pA1 =

(0.555/760)(1.01325 × 105) = 74.0 Pa, pA2 = 0, r 1 = 2/1000 m, R = 8314 m3· Pa/kg mol · K,

pB1 = P − pA1 = 1.01325 × 105 − 74.0 = 1.01251 × 105 Pa, pB2 = P − pA2 = 1.01325 × 105 − 0.
Since the values of pB1 and pB2 are close to each other,

Substituting into Eq. (6.2-32),

If the sphere in Fig. 6.2-3a is evaporating, the radius r of the sphere decreases slowly with time. The
equation for the time it takes for the sphere to evaporate completely can be derived by assuming pseudo-
steady state and by equating the diffusion flux equation (6.2-32), where r is now a variable, to the moles
of solid A evaporated per dt time and per unit area as calculated from a material balance. (See Problem
6.2-9 for this case.) The material-balance method is similar to Example 6.2-3. The final equation is

Equation 6.2-34

where r 1 is the original sphere radius, ρA the density of the sphere, and MA the molecular weight.

2. Diffu sion t hr ou g h a  cond u it  of nonu nifor m cr oss-sect iona l a r ea

In Fig. 6.2-3b component A is diffusion at steady state through a circular conduit which is tapered
uniformally as shown. At point 1 the radius is r 1 and at point 2 it is r 2. At position z in the conduit, for A
diffusing through stagnant, nondiffusing B,

Equation 6.2-35

Using the geometry shown, the variable radius r can be related to position z in the path as follows:

Equation 6.2-36

This value of r is then substituted into Eq. (6.2-35) to eliminate r and the equation integrated:

Equation 6.2-37

[View full size image]

A case similar to this is given in Problem 6.2-10.

6 .2E. Diffu sion C oe fficie nts for  G ase s

1. Exp er iment a l d et er mina t ion of d iffu sion coefficient s

A number of different experimental methods have been used to determine the molecular diffusivity for
binary gas mixtures. Several of the important methods are as follows. One method is to evaporate a pure
liquid in a narrow tube with a gas passed over the top, as shown in Fig. 6.2-2a. The fall in liquid level is
measured with time and the diffusivity calculated from Eq. (6.2-26).
In another method, two pure gases having equal pressures are placed in separate sections of a long tube
separated by a partition. The partition is slowly removed and diffusion proceeds. After a given time the
partition is reinserted and the gas in each section analyzed. The diffusivities of the vapor of solids such as
naphthalene, iodine, and benzoic acid in a gas have been obtained by measuring the rate of evaporation
of a sphere. Equation (6.2-32) can be used. See Problem 6.2-9 for an example of this.

A method often used is the two-bulb method (N1). The apparatus consists of two glass bulbs with
volumes V1 and V2 m3 connected by a capillary of cross-sectional area A m2 and length L whose volume
is small compared to V1 and V2, as shown in Fig. 6.2-4. Pure gas A is added to V1 and pure B to V2 at the
same pressures. The valve is opened, diffusion proceeds for a given time, and then the valve is closed and
the mixed contents of each chamber are sampled separately.

Figure 6.2-4. Diffusivity measurement of gases by the two-bulb method.

The equations can be derived by neglecting the capillary volume and assuming each bulb is always of a
uniform concentration. Assuming quasi-steady-state diffusion in the capillary,

Equation 6.2-38

where c2 is the concentration of A in V2 at time t and c1 in V1. The rate of diffusion of A going to V2 is
equal to the rate of accumulation in V2:

Equation 6.2-39

The average value cav  at equilibrium can be calculated by a material balance from the starting

compositions   and   at t = 0:

Equation 6.2-40
A similar balance at time t gives

Equation 6.2-41

Substituting c1 from Eq. (6.2-41) into (6.2-39), rearranging, and integrating between t = 0 and t = t, the
final equation is

Equation 6.2-42

If c2 is obtained by sampling at t, DAB can be calculated.

2. Exp er iment a l d iffu siv it y  d a t a

Some typical data are given in Table 6.2-1. Other data are tabulated in Perry and Green (P1) and Reid et
al. (R1). The values range from about 0.05 × 10−4 m2/s, where a large molecule is present, to about 1.0 ×
10−4 m2/s, where H2 is present at room temperatures. The relation between diffusivity in m2/s and ft 2/h

is 1 m2/s = 3.875 × 104 ft 2/h.

Table 6.2-1. Diffusion Coefficients of Gases at 101.32 kPa Pressure

Temperature

System °C K Diffusivity [(m 2 /s)104  or cm 2 /s] Ref.

Air–NH3 0 273 0.198 (W1)

Air–H2 O 0 273 0.220 (N2)

  25 298 0.260 (L1)

  42 315 0.288 (M1)


Air–CO2 3 276 0.142 (H1)

  44 317 0.177  

Air–H2 0 273 0.611 (N2)

Air–C2 H5 OH 25 298 0.135 (M1)

  42 315 0.145  

Air–CH3 COOH 0 273 0.106 (N2)

Air–n-hexane 21 294 0.080 (C1)


Air–benzene 25 298 0.0962 (L1)
Air–toluene 25.9 298.9 0.086 (G1)
Air–n-butanol 0 273 0.0703 (N2)

  25.9 298.9 0.087  

H2 –CH4 25 298 0.726 (C2)

H2 –N2 25 298 0.784 (B1)

  85 358 1.052  
H2 –benzene 38.1 311.1 0.404 (H2)

H2 –Ar 22.4 295.4 0.83 (W2)

H2 –NH3 25 298 0.783 (B1)

H2 –SO2 50 323 0.61 (S1)

H2 –C2 H5 OH 67 340 0.586 (T1)

He–Ar 25 298 0.729 (S2)


He–n-butanol 150 423 0.587 (S2)

He–air 44 317 0.765 (H1)


He–CH4 25 298 0.675 (C2)

He–N2 25 298 0.687 (S2)

He–O2 25 298 0.729 (S2)

Ar–CH4 25 298 0.202 (C2)

CO2 –N2 25 298 0.167 (W3)

CO2 –O2 20 293 0.153 (W4)

N2 –n-butane 25 298 0.0960 (B2)

H2 O–CO2 34.3 307.3 0.202 (S3)

CO–N2 100 373 0.318 (A1)

CH3 Cl–SO2 30 303 0.0693 (C3)

(C2 H5 )2 O–NH3 26.5 299.5 0.1078 (S4)

3. Pr ed ict ion of d iffu siv it y  for  g a ses

The diffusivity of a binary gas mixture in the dilute gas region, that is, at low pressures near atmospheric,
can be predicted using the kinetic theory of gases. The gas is assumed to consist of rigid spherical
particles that are completely elastic on collision with another molecule, which implies that momentum is
conserved.

In a simplified treatment it is assumed that there are no attractive or repulsive forces between the
molecules. The derivation uses the mean free path λ, which is the average distance that a molecule has
traveled between collisions. The final equation is

Equation 6.2-43
where ū is the average velocity of the molecules. The final equation obtained after substituting
expressions for ū and λ into Eq. (6.2-43) is approximately correct, since it correctly predicts DAB
proportional to 1/pressure and approximately predicts the temperature effect.

A more accurate and rigorous treatment must consider the intermolecular forces of attraction and
repulsion between molecules as well as the different sizes of molecules A and B. Chapman and Enskog
(H3) solved the Boltzmann equation, which uses a distribution function instead of the mean free path λ.
To solve the equation, a relation between the attractive and repulsive forces between a given pair of
molecules must be used. For a pair of nonpolar molecules, a reasonable approximation to the forces is the
Lennard–Jones function.

The final relation for predicting the diffusivity of a binary gas pair of A and B molecules is

Equation 6.2-44

where DAB is the diffusivity in m2/s, T temperature in K, MA molecular weight of A in kg mass/kg mol,
MB molecular weight of B, and P absolute pressure in atm. The term σAB is an “average collision
diameter” and ΩD,AB is a collision integral based on the Lennard–Jones potential. Values of σA and σB as
well as ΩD,AB can be obtained from a number of sources (B3, G2, H3, R1).

The collision integral ΩD,AB is a ratio giving the deviation of a gas with interactions as compared to a gas
of rigid, elastic spheres. This value would be 1.0 for a gas with no interactions. Equation (6.2-44)
predicts diffusivities with an average deviation of about 8% up to about 1000 K (R1). For a polar–
nonpolar gas mixture, Eq. (6.2-44) can be used if the correct force constant is used for the polar gas (M1,
M2). For polar–polar gas pairs, the potential-energy function commonly used is the Stockmayer
potential (M2).

The effect of concentration of A in B in Eq. (6.2-44) is not included. However, for real gases with
interactions, the maximum effect of concentration on diffusivity is about 4% (G2). In most cases the
effect is considerably less, and hence it is usually neglected.

Equation (6.2-44) is relatively complicated to use, and often some of the constants such as σAB are not
available or are difficult to estimate. Hence, the semiempirical method of Fuller et al. (F1), which is much
more convenient to use is often preferred. The equation was obtained by correlating many recent data and
uses atomic volumes from Table 6.2-2, which are summed for each gas molecule. The equation is

Equation 6.2-45
Table 6.2-2. Atomic Diffusion Volumes for Use with the Fuller, Schettler, and Giddings Method[*]
Atomic and structural diffusion volume increments, v
C 16.5 (C1) 19.5

H 1.98 (S) 17.0


O 5.48 Aromatic ring −20.2
(N) 5.69 Heterocyclic ring −20.2

Diffusion volumes for simple molecules, Ε v
H2 7.07 CO 18.9

D2 6.70 CO2 26.9

He 2.88 N2 O 35.9

N2 17.9 NH3 14.9

O2 16.6 H2 O 12.7

Air 20.1 (CCl2 F2 ) 114.8

Ar 16.1 (SF6 ) 69.7

Kr 22.8 (Cl2 ) 37.7

(Xe) 37.9 (Br2 ) 67.2

Ne 5.59 (SO2 ) 41.1


Source: Reprinted with permission from E. N. Fuller, P. D. Schettler, and J. C. Giddings, Ind. Eng.
Chem., 58, 19(1966). Copyright by the American Chemical Society.

[*]
 Parentheses indicate that the value listed is based on only a few data points.

where Ε vA = sum of structural volume increments, Table 6.2-2, and DAB = m2/s. This method can be
used for mixtures of nonpolar gases or for a polar–nonpolar mixture. Its accuracy is not quite as good as
that of Eq. (6.2-44).

The equation shows that DAB is proportional to 1/P and to T1.75. If an experimental value of DAB is
available at a given T and P and it is desired to have a value of DAB at another T and P, one should correct

the experimental value to the new T and P by means of the relationship DAB ∝ T1.75/P.

4 . S chmid t  nu mb er  of g a ses

The Schmidt number of a gas mixture of dilute A in B is dimensionless and is defined as

Equation 6.2-46

where µ is viscosity of the gas mixture, which is viscosity of B for a dilute mixture in Pa · s or kg/m · s,
DAB is diffusivity in m2/s, and ρ is the density of the mixture in kg/m3. For a gas the Schmidt number
can be assumed independent of temperature over moderate ranges and independent of pressure up to
about 10 atm or 10 × 105 Pa.

The Schmidt number is the dimensionless ratio of the molecular momentum diffusivity μ/ρ to the
molecular mass diffusivity DAB. Values of the Schmidt number for gases range from about 0.5 to 2. For
liquids Schmidt numbers range from about 100 to over 10 000 for viscous liquids.

EXAMPLE 6.2-5. Estimation of Diffusivity of a Gas Mixture
Normal butanol (A) is diffusing through air (B) at 1 atm abs. Using the Fuller et al. method,
estimate the diffusivity DAB for the following temperatures and compare with the
experimental data:

a.  For 0°C.

b.  For 25.9°C.

c.  For 0°C and 2.0 atm abs.

S olu t ion: For part (a), P = 1.00 atm, T = 273 + 0 = 273 K, MA (butanol) = 74.1, MB (air) = 29.
From Table 6.2-2,

Substituting into Eq. (6.2-45),

This value deviates by +10% from the experimental value of 7.03 × 10−6 m2/s from Table 6.2-1.

For part (b), T = 273 + 25.9 = 298.9. Substituting into Eq. (6.2-45), DAB = 9.05 × 10−6 m2/s.

This value deviates by +4% from the experimental value of 8.70 × 10−6 m2/s.

For part (c), the total pressure P = 2.0 atm. Using the value predicted in part (a) and
correcting for pressure,
                             
                                                 
                                             
                                               
     

6.3. MOLECULAR DIFFUSION IN LIQUIDS

6 .3A. Intr od u ction

Diffusion of solutes in liquids is very important in many industrial processes, especially in such
separation operations as liquid–liquid extraction or solvent extraction, gas absorption, and distillation.
Diffusion in liquids also occurs in many situations in nature, such as oxygenation of rivers and lakes by
the air and diffusion of salts in blood.

It should be apparent that the rate of molecular diffusion in liquids is considerably slower than in gases.
The molecules in a liquid are very close together compared to a gas. Hence, the molecules of the diffusing
solute A will collide with molecules of liquid B more often and diffuse more slowly than in gases. In
general, the diffusion coefficient in a gas will be on the order of magnitude of about 105 times greater than
in a liquid. However, the flux in a gas is not that much greater, being only about 100 times faster, since
the concentrations in liquids are considerably higher than in gases.

6 .3B. Eq u ations for  Diffu sion in Liq u id s

Since the molecules in a liquid are packed together much more closely than in gases, the density and the
resistance to diffusion in a liquid are much greater. Also, because of this closer spacing of the molecules,
the attractive forces between molecules play an important role in diffusion. Since the kinetic theory of
liquids is only partially developed, we write the equations for diffusion in liquids similar to those for
gases.

In diffusion in liquids an important difference from diffusion in gases is that the diffusivities are often
quite dependent on the concentration of the diffusing components.

1. Eq u imola r  cou nt er d iffu sion

Starting with the general equation (6.2-14), we can obtain for equimolal counterdiffusion, where NA =
−NB, an equation similar to Eq. (6.1-11) for gases at steady state:

Equation 6.3-1

where NA is the flux of A in kg mol A/s · m2, DAB the diffusivity of A in B in m2/s, cA1 the concentration of

A in kg mol A/m3 at point 1, xA1 the mole fraction of A at point 1, and cav  defined by

Equation 6.3-2
where cav  is the average total concentration of A + B in kg mol/m3, M1 the average molecular weight of

the solution at point 1 in kg mass/kg mol, and ρ1 the average density of the solution in kg/m3 at point 1.

Equation (6.3-1) uses the average value of DAB, which may vary some with concentration, and the
average value of c, which may also vary with concentration. Usually, the linear average of c is used, as in
Eq. (6.3-2). The case of equimolar counterdiffusion in Eq. (6.3-1) only occurs very infrequently in liquids.

2. Diffu sion of A t hr ou g h nond iffu sing  B

The most important case of diffusion in liquids is that where solute A is diffusing and solvent B is
stagnant or nondiffusing. An example is a dilute solution of propionic acid (A) in a water (B) solution
being contacted with toluene. Only the propionic acid (A) diffuses through the water phase, to the
boundary, and then into the toluene phase. The toluene–water interface is a barrier to diffusion of B and
NB = 0. Such cases often occur in industry (T2). If Eq. (6.2-22) is rewritten in terms of concentrations by
substituting cav  = P/RT, cA1 = pA1/RT, and xBM = pBM/P, we obtain the equation for liquids at steady
state:

Equation 6.3-3

where

Equation 6.3-4

Note that xA1 + xB1 = xA2 + xB2 = 1.0. For dilute solutions xBM is close to 1.0 and c is essentially constant.
Then Eq. (6.3-3) simplifies to

Equation 6.3-5

EXAMPLE 6.3-1. Diffusion of Ethanol (A) Through Water
(B)
An ethanol (A)–water (B) solution in the form of a stagnant film 2.0 mm thick at 293 K is in
contact at one surface with an organic solvent in which ethanol is soluble and water is
insoluble. Hence, NB = 0. At point 1 the concentration of ethanol is 16.8 wt % and the solution

density is ρ1 = 972.8 kg/m3. At point 2 the concentration of ethanol is 6.8 wt % and ρ2 = 988.1

kg/m3 (P1). The diffusivity of ethanol is 0.740 × 10−9 m2/s (T2). Calculate the steady-state
flux NA.

S olu t ion: The diffusivity is DAB = 0.740 × 10−9 m2/s. The molecular weights of A and B are
MA = 46.05 and MB = 18.02. For a wt % of 6.8, the mole fraction of ethanol (A) is as follows
when using 100 kg of solution:

Then xB2 = 1 − 0.0277 = 0.9723. Calculating xA1 in a similar manner, xA1 = 0.0732 and xB1 = 1
− 0.0732 = 0.9268. To calculate the molecular weight M2 at point 2,

Similarly, M1 = 20.07. From Eq. (6.3-2),

[View full size image]

To calculate xBM from Eq. (6.3-4), we can use the linear mean since xB1 and xB2 are close to
each other:

Substituting into Eq. (6.3-3) and solving,

6 .3C . Diffu sion C oe fficie nts for  Liq u id s

1. Exp er iment a l d et er mina t ion of d iffu siv it ies

Several different methods are used to determine diffusion coefficients experimentally in liquids. In one
method, unsteady-state diffusion in a long capillary tube is carried out and the diffusivity determined
from the concentration profile. If the solute A is diffusing in B, the diffusion coefficient determined is
DAB. Also, the value of diffusivity is often very dependent upon the concentration of the diffusing solute
A. For liquids, unlike gases, the diffusivity DAB does not equal DBA.

In a fairly common method a relatively dilute solution and a slightly more concentrated solution are
placed in chambers on opposite sides of a porous membrane of sintered glass as shown in Fig. 6.3-1.
Molecular diffusion takes place through the narrow passageways of the pores in the sintered glass while
the two compartments are stirred. The effective diffusion length is τδ, where the tortuosity τ > 1 is a
constant and corrects for the fact that the path is actually greater than δ cm. In this method, discussed
by Bidstrup and Geankoplis (B4), the effective diffusion length is obtained by calibrating with a solute
such as KCl having a known diffusivity.

Figure 6.3-1. Diffusion cell for determination of diffusivity in a liquid.

To derive the equation, quasi-steady-state diffusion in the membrane is assumed:

Equation 6.3-6

where c is the concentration in the lower chamber at a time t, c' is the concentration in the upper
chamber, and ε is the fraction of area of the glass open to diffusion. Making a balance on solute A in the
upper chamber, where the rate in = rate out + rate of accumulation, making a similar balance on the
lower chamber, using volume V = V', and combining and integrating, the final equation is

Equation 6.3-7

where 2εA/τδV is a cell constant that can be determined using a solute of known diffusivity, such as KCl.

The values c0 and   are initial concentrations and c and   final concentrations.

2. Exp er iment a l liq u id  d iffu siv it y  d a t a


Experimental diffusivity data for binary mixtures in the liquid phase are given in Table 6.3-1. All the data
are for dilute solutions of the diffusing solute in the solvent. In liquids the diffusivities often vary quite
markedly with concentration. Hence, the values in Table 6.3-1 should be used with some caution when
outside the dilute range. Additional data are given in (P1). Values for biological solutes in solution are
given in the next section. As noted in the table, the diffusivity values are quite small and in the range of
about 0.5 × 10−9 to 5 × 10−9 m2/s for relatively nonviscous liquids. Diffusivities in gases are larger by a
factor of 104–105.

Table 6.3-1. Diffusion Coefficients for Dilute Liquid Solutions

Temperature Diffusivity
[(m 2 /s)109  or
Solute Solvent °C K (cm 2 /s)105 ] Ref.

NH3 Water 12 285 1.64 (N2)

    15 288 1.77  
O2 Water 18 291 1.98 (N2)

    25 298 2.41 (V1)

CO2 Water 25 298 2.00 (V1)

H2 Water 25 298 4.8 (V1)

Methyl alcohol Water 15 288 1.26 (J1)

Ethyl alcohol Water 10 283 0.84 (J1)

    25 298 1.24 (J1)

n-Propyl alcohol Water 15 288 0.87 (J1)

Formic acid Water 25 298 1.52 (B4)

Acetic acid Water 9.7 282.7 0.769 (B4)

    25 298 1.26 (B4)

Propionic acid Water 25 298 1.01 (B4)


HCl (9 g mol/liter) Water 10 283 3.3 (N2)

  10 283 2.5 (N2)


(2.5 g
mol/liter)

Benzoic acid Water 25 298 1.21 (C4)

Acetone Water 25 298 1.28 (A2)


Acetic acid Benzene 25 298 2.09 (C5)

Urea Ethanol 12 285 0.54 (N2)


Water Ethanol 25 298 1.13 (H4)
KCl Water 25 298 1.870 (P2)

KCl Ethylene glycol 25 298 0.119 (P2)

6 .3D. Pr e d iction of Diffu siv itie s in Liq u id s


The equations for predicting diffusivities of dilute solutes in liquids are by necessity semiempirical, since
the theory for diffusion in liquids is not well established as yet. The Stokes–Einstein equation, one of the
first theories, was derived for a very large spherical molecule (A) diffusing in a liquid solvent (B) of small
molecules. Stokes' law was used to describe the drag on the moving solute molecule. Then the equation
was modified by assuming that all molecules are alike and arranged in a cubic lattice, and by expressing
the molecular radius in terms of the molar volume (W5),

Equation 6.3-8

where DAB is diffusivity in m2/s, T is temperature in K, μ is viscosity of solution in Pa · s or kg/m · s, and

VA is the solute molar volume at its normal boiling point in m3/kg mol. This equation applies very well to
very large unhydrated and sphere-like solute molecules of about 1000 molecular weight or greater (R1),
or where the VA is above about 0.500 m3/kg mol (W5) in aqueous solution.

For smaller solute molar volumes, Eq. (6.3-8) does not hold. Several other theoretical derivations have
been attempted, but the equations do not predict diffusivities very accurately. Hence, a number of
semitheoretical expressions have been developed (R1). The Wilke–Chang (T3, W5) correlation can be
used for most general purposes where the solute (A) is dilute in the solvent (B):

Equation 6.3-9

where MB is the molecular weight of solvent B, μB is the viscosity of B in Pa · s or kg/m · s, VA is the solute
molar volume at the boiling point (L2), which can be obtained from Table 6.3-2, and φ is an “association
parameter” of the solvent, where φ is 2.6 for water, 1.9 for methanol, 1.5 for ethanol, 1.0 for benzene, 1.0
for ether, 1.0 for heptane, and 1.0 for other unassociated solvents. When values of VA are above 0.500

m3/kg mol (500 cm3/g mol), Eq. (6.3-8) should be used.

Table 6.3-2. Atomic and Molar Volumes at the Normal Boiling Point

Material Atomic Material Atomic Volume


( 3
Volume m /kg (m 3 /kg mol) 103
mol) 103

C 14.8 Ring, 3-membered −6
as in ethylene
H 3.7 oxide
O (except as below) 7.4
  Doubly bound as carbonyl 7.4 4-membered 5- −8.5 −11.5
membered
  Coupled to two other elements   6-membered −15 −30
Naphthalene ring
    In aldehydes, ketones 7.4 Anthracene ring −47.5
    In methyl esters 9.1    
    In methyl ethers 9.9    

    In ethyl esters 9.9    
    In ethyl ethers 9.9   Molecular Volume
(m3 /kg mol) 103
    In higher esters 11.0  

    In higher ethers 11.0 Air 29.9


    In acids (−OH) 12.0 O2 25.6

  Joined to S, P, N 8.3 N2 31.2

N   Br2 53.2

  Doubly bonded 15.6 Cl2 48.4

  In primary amines 10.5 CO 30.7


  In secondary amines 12.0 CO2 34.0

Br     27.0   H2 14.3

Cl in RCHClR' 24.6 H2 O 18.8

Cl in RCl (terminal) 21.6 H2 S 32.9

F 8.7 NH3 25.8

I 37.0 NO 23.6

S 25.6 N2 O 36.4

P 27.0 SO2 44.8


Source: G. Le Bas, The Molecular Volumes of Liquid Chemical Compounds. New York: David McKay
Co., Inc., 1915.

When water is the solute, values from Eq. (6.3-9) should be multiplied by a factor of 1/2.3 (R1). Equation
(6.3-9) predicts diffusivities with a mean deviation of 10–15% for aqueous solutions and about 25% in
nonaqueous solutions. Outside the range 278–313 K, the equation should be used with caution. For
water as the diffusing solute, an equation by Reddy and Doraiswamy is preferred (R2). Skelland (S5)
summarizes the correlations available for binary systems. Geankoplis (G2) discusses and gives an
equation to predict diffusion in a ternary system, where a dilute solute A is diffusing in a mixture of B
and C solvents. This case is often approximated in industrial processes.

EXAMPLE 6.3-2. Prediction of Liquid Diffusivity
Predict the diffusion coefficient of acetone (CH3COCH3) in water at 25° and 50°C using the

Wilke–Chang equation. The experimental value is 1.28 × 10−9 m2/s at 25°C (298 K).

S olu t ion: From Appendix A.2 the viscosity of water at 25.0°C is μB = 0.8937 × 10−3 Pas and

at 50°C, 0.5494 × 10−3. From Table 6.3-2 for CH3COCH3 with 3 carbons + 6 hydrogens + 1
oxygen,
For water the association parameter φ = 2.6 and MB = 18.02 kg mass/kg mol. For 25°C, T =
298 K. Substituting into Eq. (6.3-9),

For 50°C or T = 323 K,

6 .3E. Pr e d iction of Diffu siv itie s of Ele ctr olyte s in Liq u id s

Electrolytes in aqueous solution such as KCl dissociate into cations and anions. Each ion diffuses at a
different rate. If the solution is to remain electrically neutral at each point (assuming the absence of any
applied electric-potential field), the cations and anions diffuse effectively as one component, and the ions
have the same net motion or flux. Hence, the average diffusivity of the electrolyte KCl is a combination of
the diffusion coefficients of the two ions. Its value is in between the diffusivity values for the two ions.

The well-known Nernst–Haskell equation for dilute, single-salt solutions can be used at 25°C to predict
the overall diffusivity DAB of the salt A in the solvent B (R1):

Equation 6.3-10

where   is in cm2/s, n+ is the valence of the cation, n− is the valence of the anion, and λ + and λ − are

the limiting ionic conductances in very dilute solutions in (A/cm2)(V/cm)(g equiv./cm2). Values of the
conductances are given in Table 6.3-3 at 25°C. The value of T = 298.2 in Eq. (6.3-10) when using values
of λ + and λ − at 25°C.

Table 6.3-3. Limiting Ionic Conductances in Water at 25°C (R4)

Anion λ− Cation λ+

OH− 197.6 H+ 349.8

76.3 38.7
Cl− Li+
Br− 78.3 Na+ 50.1

71.4 K+ 73.5

40.9 73.4

80 59.5

68.0 53

    69.5

Ionic conductances in (A/cm2 )(V/cm)(g equiv./cm2 )

The diffusion coefficient of an individual ion i at 25°C can be calculated from

Equation 6.3-11

Then Eq. (6.3-10) becomes as follows:

Equation 6.3-12

To correct   for temperature, first calculate   at 25°C from Eq. (6.3-10) using the λ + and λ − values

given in Table 6.3-3 at 25°C. Then, multiply this   at 25°C by T/(334 μW), where μW is the viscosity
of water in cp at the new T (R1).

EXAMPLE 6.3-3. Diffusivities of Electrolytes
Predict the diffusion coefficients of dilute electrolytes for the following cases:

a.  For KCl at 25°C, predict   and compare with the value in Table 6.3-1.

b.  Predict the value for KCl at 18.5°C. The experimental value is 1.7 × 10−5 cm2/s (S9).

c.  For CaCl2 predict DAB at 25°C. Compare with the experimental value of 1.32 × 10−5

cm2/s (C10). Also predict Di of the ion Ca2+ and of Cl− and use Eq. (6.3-12).

S olu t ion: For part (a) from Table 6.3-3, λ +(K+) = 73.5 and λ −(Cl−) = 76.3. Substituting into


Eq. (6.3-10),

The experimental value in Table 6.3-1 is 1.87 × 10−5 cm2/s, which is reasonably close
considering that this value is not at infinite dilution.

For part (b) the correction factor for temperature is T/(334 μw ). For T = 273.2 + 18.5 = 291.7 K
from Table A.2-4, μw  = 1.042 cp. Then T/(334 μw ) = 291.7/(334 × 1.042) = 0.8382. Correcting

the value of   at 25°C to 18.5°C,

This compares with the experimental value of 1.7 × 10−5 cm2/s.

For part (c), for CaCl2, from Table 6.3-3, λ +(Ca2+/2) = 59.5, λ −(Cl−) = 76.3, n+ = 2, and n− = 1.


Again, using Eq. (6.3-10),

This compares well with the experimental value of 1.32 × 10−5 (C10).

To calculate the individual ion diffusivities at 25°C using Eq. (6.3-11),

Substituting into Eq. (6.3-12) for 25°C,
Hence, one can see that the diffusivity of the salt is in between that of the two ions.
                             
                                                 
                                             
                                               
     

6.4. MOLECULAR DIFFUSION IN BIOLOGICAL SOLUTIONS AND
GELS

6 .4 A. Diffu sion of Biological S olu te s in Liq u id s

1. Int r od u ct ion

The diffusion of small solute molecules and especially macromolecules (e.g., proteins) in aqueous
solutions are important in the processing and storing of biological systems and in the life processes of
microorganisms, animals, and plants. Food processing is an important area where diffusion plays an
important role. In the drying of liquid solutions of fruit juice, coffee, and tea, water and frequently
volatile flavor or aroma constituents are removed. These constituents diffuse through the liquid during
evaporation.

In fermentation processes, nutrients, sugars, oxygen, and so on diffuse to the microorganisms, and waste
products and at times enzymes diffuse away. In the artificial kidney machine various waste products
diffuse through the blood solution to a membrane and then through the membrane to an aqueous
solution.

Macromolecules in solution having molecular weights of tens of thousands or more were often called
colloids, but now we know they generally form true solutions. The diffusion behavior of protein
macromolecules in solution is affected by their large sizes and shapes, which can be random coils,
rodlike, or globular (spheres or ellipsoids). Also, interactions of the large molecules with the small
solvent and/or solute molecules affect the diffusion of the macromolecules as well as the small solute
molecules.

Besides the Fickian diffusion to be discussed here, mediated transport often occurs in biological systems
where chemical interactions occur. This latter type of transport will not be discussed here.

2. Int er a ct ion a nd  “ b ind ing ”  in d iffu sion

Protein macromolecules are very large compared to small solute molecules such as urea, KCl, and
sodium caprylate, and often have a number of sites for interaction or “binding” of the solute or ligand
molecules. An example is the binding of oxygen to hemoglobin in the blood. Human serum albumin
protein binds most of the free fatty acids in the blood and increases their apparent solubility. Bovine
serum albumin, which is in milk, binds 23 mol sodium caprylate/mol albumin when the albumin
concentration is 30 kg/m3 solution and the sodium caprylate is about 0.05 molar (G6). Hence, Fickian-
type diffusion of macromolecules and small solute molecules can be greatly affected by the presence
together of both types of molecules even in dilute solutions.

3. Exp er iment a l met ho d s for  d et er mining  d iffu siv it y

Methods for determining the diffusivity of biological solutes are similar to those discussed previously in
Section 6.3 with some modifications. In the diaphragm diffusion cell shown in Fig. 6.3-1, the chamber is
made of Lucite® or Teflon® instead of glass, since protein molecules bind to glass. Also, the porous
membrane through which the molecular diffusion occurs is composed of cellulose acetate or other
polymers (G5, G6, K1).

4 . Exp er iment a l d a t a  for  b iolog ica l solu t es

Most of the experimental data in the literature on protein diffusivities have been extrapolated to zero
concentration since the diffusivity is often a function of concentration. A tabulation of diffusivities of a
few proteins and also of small solutes often present in biological systems is given in Table 6.4-1.

Table 6.4-1. Diffusion Coefficients for Dilute Biological Solutes in Aqueous Solution

Solute Temperature Diffusivity Molecular Ref.


(m 2 /s ) Weight
°C K

Urea 20 293 1.20 × 10−9 60.1 (N2)

  25 298 1.378 × 10−9   (G5)

Glycerol 20 293 0.825 × 10−9 92.1 (G3)

Glycine 25 298 1.055 × 10−9 75.1 (L3)

Sodium caprylate 25 298 8.78 × 10−10 166.2 (G6)

Bovine serum albumin 25 298 6.81 × 10−11 67 500 (C6)

Urease 25 298 4.01 × 10−11 482 700 (C7)

  20 293 3.46 × 10−11   (S6)

Soybean protein 20 293 2.91 × 10−11 361 800 (S6)

Lipoxidase 20 293 5.59 × 10−11 97 440 (S6)

Fibrinogen, human 20 293 1.98 × 10−11 339 700 (S6)

Human serum albumin 20 293 5.93 × 10−11 72 300 (S6)

γ-Globulin, human 20 293 4.00 × 10−11 153 100 (S6)

Creatinine 37 310 1.08 × 10−9 113.1 (C8)

Sucrose 37 310 0.697 × 10−9 342.3 (C8)

  20 293 0.460 × 10−9   (P3)

The diffusion coefficients for the large protein molecules are on the order of magnitude of 5 × 10−11 m2/s
compared to the values of about 1 × 10−9 m2/s for the small solutes in Table 6.4-1. This means
macromolecules diffuse at a rate about 20 times as slow as small solute molecules for the same
concentration differences.

When the concentration of macromolecules such as proteins increases, the diffusion coefficient would be
expected to decrease, since the diffusivity of small solute molecules decreases with increasing
concentration. However, experimental data (G4, C7) show that the diffusivity of macromolecules such as
proteins decreases in some cases and increases in others as protein concentration increases. Surface
charges on the molecules appear to play a role in these phenomena.
When small solutes such as urea, KCl, and sodium caprylate, which are often present with protein
macromolecules in solution, diffuse through these protein solutions, the diffusivity decreases with
increasing polymer concentration (C7, G5, G6, N3). Experimental data for the diffusivity of the solute
sodium caprylate (A) diffusing through bovine serum albumin (P) solution show that the diffusivity DAP
of A through P is markedly reduced as the protein (P) concentration is increased (G5, G6). A large part of
the reduction is due to the binding of A to P so that there is less free A to diffuse. The rest is due to
blockage by the large molecules.

5. Pr ed ict ion of d iffu siv it ies for  b iolog ica l solu t es

For predicting the diffusivity of small solutes alone in aqueous solution with molecular weights less than
about 1000 or solute molar volumes less than about 0.500 m3/kg mol, Eq. (6.3-9) should be used. For
larger solutes the equations to be used are not as accurate. As an approximation the Stokes–Einstein
equation (6.3-8) can be used:

Equation 6.3-8

Probably a better approximate equation to use is the semiempirical equation of Polson (P3), which is
recommended for a molecular weight above 1000. A modification of his equation to take into account
different temperatures is as follows for dilute aqueous solutions:

Equation 6.4-1

where MA is the molecular weight of the large molecule A. When the shape of the molecule deviates
greatly from a sphere, this equation should be used with caution.

EXAMPLE 6.4-1. Prediction of Diffusivity of Albumin
Predict the diffusivity of bovine serum albumin at 298 K in water as a dilute solution using the
modified Polson equation (6.4-1) and compare with the experimental value in Table 6.4-1.

S olu t ion: The molecular weight of bovine serum albumin (A) from Table 6.4-1 is MA = 67 500

kg/kg mol. The viscosity of water at 25°C is 0.8937 × 10−3 Pa · s and T = 298 K. Substituting
into Eq. (6.4-1),
This value is 11% higher than the experimental value of 6.81 × 10−11 m2/s.

6 . Pr ed ict ion of d iffu siv it y  of sma ll solu t es in p r ot ein solu t ion

When a small solute (A) diffuses through a macromolecule (P) protein solution, Eq. (6.3-9) cannot be
used for prediction for the small solute because of blockage to diffusion by the large molecules. The data
needed to predict these effects are the diffusivity DAB of solute A in water alone, the water of hydration on
the protein, and an obstruction factor. A semitheoretical equation that can be used to approximate the
diffusivity DAP of A in globular-type protein P solutions is as follows, where only the blockage effect is
considered (C8, G5, G6) and no binding is present:

Equation 6.4-2

where cp = kg P/m3. Then the diffusion equation is

Equation 6.4-3

where cA1 is concentration of A in kg mol A/m3.

7. Pr ed ict ion of d iffu siv it y  w it h b ind ing  p r esent

When A is in a protein solution P and binds to P, the diffusion flux of A is equal to the flux of unbound
solute A in the solution plus the flux of the protein–solute complex. Methods for predicting this flux are
available (G5, G6) when binding data have been experimentally obtained. The equation used is

Equation 6.4-4

where DP is the diffusivity of the protein alone in the solution, m2/s, and free A is that A not bound to the
protein, which is determined from the experimental binding coefficient. Then Eq. (6.4-3) is used to
calculate the flux, where cA is the total concentration of A in the solution.

6 .4 B. Diffu sion in Biological G e ls

Gels can be looked upon as semisolid materials which are “porous.” They are composed of
macromolecules which are usually in dilute aqueous solution with the gel comprising a few wt % of the
water solution. The “pores” or open spaces in the gel structure are filled with water. The rates of diffusion
of small solutes in the gels are somewhat less than in aqueous solution. The main effect of the gel
structure is to increase the path length for diffusion, assuming no electrical-type effects (S7).

Recent studies by electron microscopy (L4) have shown that the macromolecules of the gel agarose (a
major constituent of agar) exist as long and relatively straight threads. This suggests a gel structure of
loosely interwoven, extensively hydrogen-bonded polysaccharide macromolecules.

Some typical gels are agarose, agar, and gelatin. A number of organic polymers exist as gels in various
types of solutions. To measure the diffusivity of solutes in gels, unsteady-state methods are used. In one
method the gel is melted and poured into a narrow tube open at one end. After solidification, the tube is
placed in an agitated bath containing the solute for diffusion. The solute leaves the solution at the gel
boundary and diffuses through the gel itself. After a period of time the amount diffusing in the gel is
determined to give the diffusion coefficient of the solute in the gel.

A few typical values of diffusivities of some solutes in various gels are given in Table 6.4-2. In some cases
the diffusivity of the solute in pure water is given so that the decrease in diffusivity due to the gel can be
seen. For example, from Table 6.4-2, at 278 K urea in water has a diffusivity of 0.880 × 10−9 m2/s and in
2.9 wt % gelatin, has a value of 0.640 × 10−9 m2/s, a decrease of 27%.

Table 6.4-2. Typical Diffusivities of Solutes in Dilute Biological Gels in Aqueous Solution

Temperature

Solute Gel Wt % Gel in Solution K °C Diffusivity (m 2 /s) Ref.

Sucrose Gelatin 0 278 5 0.285 × 10−9 (F2)

    3.8 278 5 0.209 × 10−9 (F2)

    10.35 278 5 0.107 × 10−9 (F2)

    5.1 293 20 0.252 × 10−9 (F3)

Urea Gelatin 0 278 5 0.880 × 10−9 (F2)

    2.9 278 5 0.644 × 10−9 (F2)

    5.1 278 5 0.609 × 10−9 (F3)

    10.0 278 5 0.542 × 10−9 (F2)

    5.1 293 20 0.859 × 10−9 (F3)

Methanol Gelatin 3.8 278 5 0.626 × 10−9 (F3)

Urea Agar 1.05 278 5 0.727 × 10−9 (F3)

    3.16 278 5 0.591 × 10−9 (F3)

    5.15 278 5 0.472 × 10−9 (F3)

Glycerin Agar 2.06 278 5 0.297 × 10−9 (F3)

    6.02 278 5 0.199 × 10−9 (F3)

Dextrose Agar 0.79 278 5 0.327 × 10−9 (F3)

Sucrose Agar 0.79 278 5 0.247 × 10−9 (F3)

Ethanol Agar 5.15 278 5 0.393 × 10−9 (F3)

NaCl (0.05 M) Agarose 0 298 25 1.511 × 10−9 (S7)


    2 298 25 1.398 × 10−9 (S7)

In both agar and gelatin the diffusivity of a given solute decreases more or less linearly with an increase
in wt % gel. However, extrapolation to 0% gel gives a value smaller than that shown for pure water. It
should be noted that in different preparations or batches of the same type of gel, the diffusivities can vary
by as much as 10 to 20%.

EXAMPLE 6.4-2. Diffusion of Urea in Agar
A tube or bridge of a gel solution of 1.05 wt % agar in water at 278 K is 0.04 m long and
connects two agitated solutions of urea in water. The urea concentration in the first solution is
0.2 g mol urea per liter solution and is 0 in the other. Calculate the flux of urea in kg mol/s ·
m2 at steady state.

S olu t ion: From Table 6.4-2 for the solute urea at 278 K, DAB = 0.727 × 10−9 m2/s. For urea
diffusing through stagnant water in the gel, Eq. (6.3-3) can be used. However, since the value
of xA1 is less than about 0.01, the solution is quite dilute and xBM ≅ 1.00. Hence, Eq. (6.3-5)

can be used. The concentrations are cA1 = 0.20/1000 = 0.0002 g mol/cm3 = 0.20 kg mol/m3
and cA2 = 0. Substituting into Eq. (6.3-5),
                             
                                                 
                                             
                                               
     

6.5. MOLECULAR DIFFUSION IN SOLIDS

6 .5A. Intr od u ction and  Typ e s of Diffu sion in S olid s

Even though rates of diffusion of gases, liquids, and solids in solids are generally slower than rates in
liquids and gases, mass transfer in solids is quite important in chemical and biological processing. Some
examples are leaching of foods, such as soybeans, and of metal ores; drying of timber, salts, and foods;
diffusion and catalytic reaction in solid catalysts; separation of fluids by membranes; diffusion of gases
through polymer films used in packaging; and treating of metals at high temperatures by gases.

We can broadly classify transport in solids into two types of diffusion: diffusion that can be considered to
follow Fick's law and does not depend primarily on the actual structure of the solid, and diffusion in
porous solids where the actual structure and void channels are important. These two broad types of
diffusion will be considered.

6 .5B. Diffu sion in S olid s Follow ing Fick's Law

1. Der iv a t ion of eq u a t ions

This type of diffusion in solids does not depend on the actual structure of the solid. The diffusion occurs
when the fluid or solute diffusing is actually dissolved in the solid to form a more or less homogeneous
solution—for example, in leaching, where the solid contains a large amount of water and a solute is
diffusing through this solution, or in the diffusion of zinc through copper, where solid solutions are
present. Also, the diffusion of nitrogen or hydrogen through rubber, or in some cases diffusion of water in
foodstuffs, can be classified here, since equations of similar type can be used.

Generally, simplified equations are used. Using the general Eq. (6.2-14) for binary diffusion,

Equation 6.2-14

the bulk-flow term, (cA/c)(NA + NB), even if present, is usually small, since cA/c or xA is quite small.
Hence, it is neglected. Also, c is assumed constant, giving for diffusion in solids

Equation 6.5-1

where DAB is diffusivity in m2/s of A through B and is usually assumed constant, independent of
pressure for solids. Note that DAB ≠ DBA in solids.
Integration of Eq. (6.5-1) for a solid slab at steady state gives

Equation 6.5-2

For the case of diffusion radially through a cylinder wall of inner radius r 1 and outer r 2 and length L,

Equation 6.5-3

Equation 6.5-4

This case is similar to conduction heat transfer radially through a hollow cylinder, as shown in Fig. 4.3-
2.

The diffusion coefficient DAB in the solid as stated above is not dependent upon the pressure of the gas or
liquid on the outside of the solid. For example, if CO2 gas is outside a slab of rubber and is diffusing
through the rubber, DAB would be independent of pA, the partial pressure of CO2 at the surface. The
solubility of CO2 in the solid, however, is directly proportional to pA. This is similar to the case of the
solubility of O2 in water being directly proportional to the partial pressure of O2 in the air by Henry's law.

The solubility of a solute gas (A) in a solid is usually expressed as S in m3 solute (at STP of 0°C and 1
atm) per m3 solid per atm partial pressure of (A). Also, S = cm3(STP)/atm · cm3 solid in the cgs system.
To convert this to cA concentration in the solid in kg mol A/m3 using SI units,

Equation 6.5-5

Using cgs units,

Equation 6.5-6
EXAMPLE 6.5-1. Diffusion of H2 Through Neoprene
Membrane
The gas hydrogen at 17°C and 0.010 atm partial pressure is diffusing through a membrane of
vulcanized neoprene rubber 0.5 mm thick. The pressure of H2 on the other side of the neoprene
is zero. Calculate the steady-state flux, assuming that the only resistance to diffusion is in the
membrane. The solubility S of H2 gas in neoprene at 17°C is 0.051 m3 (at STP of 0°C and 1

atm)/m3 solid · atm and the diffusivity DAB is 1.03 × 10−10 m2/s at 17°C.

S olu t ion: A sketch showing the concentration is shown in Fig. 6.5-1. The equilibrium
concentration cA1 at the inside surface of the rubber is, from Eq. (6.5-5),

Figure 6.5-1. Concentrations for Example 6.5-1.

Since pA2 at the other side is 0, cA2 = 0. Substituting into Eq. (6.5-2) and solving,

2. Per mea b ilit y  eq u a t ions for  d iffu sion in solid s

In many cases the experimental data for diffusion of gases in solids are not given as diffusivities and
solubilities but as permeabilities, PM, in m3 of solute gas A at STP (0°C and 1 atm press) diffusing per

second per m2 cross-sectional area through a solid 1 m thick under a pressure difference of 1 atm
pressure. This can be related to Fick's equation (6.5-2) as follows:

Equation 6.5-2
From Eq. (6.5-5),

Equation 6.5-7

Substituting Eq. (6.5-7) into (6.5-2),

Equation 6.5-8

where the permeability PM is

Equation 6.5-9

Permeability (PM) is also given in the literature in several other sets of units. For the cgs system, the

permeability is given as cm3(STP)/(s · cm2C.S. · atm/cm). In some cases in the literature the
permeability is given as cm3(STP)/(s · cm2C.S. · cm Hg/cm thickness). These are related as follows:

Equation 6.5-10

Equation 6.5-11

When there are several solids 1, 2, 3, . . . , in series and L1, L2, . . . , represent the thickness of each, then
Eq. (6.5-8) becomes

Equation 6.5-12
where pA1 − pA2 is the overall partial pressure difference.

3. Exp er iment a l d iffu siv it ies, solu b ilit ies, a nd  p er mea b ilit ies

Accurate prediction of diffusivities in solids is generally not possible because of the lack of knowledge of
the theory of the solid state. Hence, experimental values are needed. Some experimental data for
diffusivities, solubilities, and permeabilities are given in Table 6.5-1 for gases diffusing in solids and
solids diffusing in solids.

Table 6.5-1. Diffusivities and Permeabilities in Solids

DAB, Diffusion Solubility, S Permeability, PM


Solute Coefficient
(A) Solid (B) T (K) [m2/s] Ref.

H2 Vulcanized 298 0.85(10−9 ) 0.040 0.342(10−10 ) (B5)


rubber

O2   298 0.21(10−9 ) 0.070 0.152(10−10 ) (B5)

N2   298 0.15(10−9 ) 0.035 0.054(10−10 ) (B5)

CO2   298 0.11(10−9 ) 0.90 1.01(10−10 ) (B5)

H2 Vulcanized 290 0.103(10−9 ) 0.051   (B5)


neoprene

    300 0.180(10−9 ) 0.053   (B5)

H2 Polyethylene 298     6.53(10−12 ) (R3)

O2   303     4.17(10−12 ) (R3)

N2   303     1.52(10−12 ) (R3)

O2 Nylon 303     0.029(10−12 ) (R3)

N2   303     0.0152(10−12 ) (R3)

Air English          
  leather 298     0.15−0.68 × 10−4 (B5)

H2 O Wax 306     0.16(10−10 ) (B5)

H2 O Cellophane 311     0.91−1.82(10−10 ) (B5)

He Pyrex glass 293     4.86(10−15 ) (B5)

    373     20.1(10−15 ) (B5)

He SiO2 293 2.4−5.5(10−14 ) 0.01   (B5)

H2 Fe 293 2.59(10−13 )     (B5)

Al Cu 293 1.3(10−34 )     (B5)


For the simple gases such as He, H2, O2, N2, and CO2, with gas pressures up to 1 or 2 atm, the solubility
in solids such as polymers and glasses generally follows Henry's law and Eq. (6.5-5) holds. Also, for
these gases the diffusivity and permeability are independent of concentration, and hence pressure. For
the effect of temperature T in K, the ln PM is approximately a linear function of 1/T. Also, the diffusion of
one gas, say H2, is approximately independent of the other gases present, such as O2 and N2.

For metals such as Ni, Cd, and Pt, where gases such as H2 and O2 are diffusing, it has been found

experimentally that the flux is approximately proportional to ( ) so Eq. (6.5-8) does not
hold (B5). When water is diffusing through polymers, unlike the simple gases, PM may depend
somewhat on the relative pressure difference (C9, B5). Further data are available in monographs by
Crank and Park (C9) and Barrer (B5).

EXAMPLE 6.5-2. Diffusion Through a Packaging Film
Using Permeability
A polyethylene film 0.00015 m (0.15 mm) thick is being considered for use in packaging a
pharmaceutical product at 30°C. If the partial pressure of O2 outside the package is 0.21 atm
and inside it is 0.01 atm, calculate the diffusion flux of O2 at steady state. Use permeability
data from Table 6.5-1. Assume that the resistances to diffusion outside the film and inside are
negligible compared to the resistance of the film.

S olu t ion: From Table 6.5-1, PM = 4.17(10−12) m3 solute(STP)/(s · m2 · atm/m). Substituting
into Eq. (6.5-8),

Note that a film made of nylon has a much smaller value of permeability PM for O2 and would
make a more suitable barrier.

4 . M emb r a ne sep a r a t ion p r ocesses

In Chapter 13 a detailed discussion is given of the various membrane separation processes for gas
separation by membranes, dialysis, reverse osmosis, ultrafiltration, and microfiltration.

6 .5C . Diffu sion in Por ou s S olid s That De p e nd s on S tr u ctu r e

1. Diffu sion of liq u id s in p or ou s solid s

In Section 6.5B we used Fick's law and treated the solid as a uniform homogeneous-like material with an
experimental diffusivity DAB. In this section we are concerned with porous solids that have pores or
interconnected voids in the solid which affect the diffusion. A cross section of a typical porous solid is
shown in Fig. 6.5-2.
Figure 6.5-2. Sketch of a typical porous solid.

For the situation where the voids are filled completely with liquid water, the concentration of salt in
water at boundary 1 is cA1 and at point 2 is cA2. The salt, in diffusing through the water in the void
volume, takes a tortuous path which is unknown and greater than (z2 − z1) by a factor τ, called
tortuosity. Diffusion does not occur in the inert solid. For a dilute solution using Eq. (6.3-5) for diffusion
of salt in water at steady state,

Equation 6.5-13

where ε is the open void fraction, DAB is the diffusivity of salt in water, and τ is a factor which corrects for
the path longer than (z2 − z1). For inert-type solids τ can vary from about 1.5 to 5. Often the terms are
combined into an effective diffusivity:

Equation 6.5-14

EXAMPLE 6.5-3. Diffusion of KCl in Porous Silica
A sintered solid of silica 2.0 mm thick is porous, with a void fraction ε of 0.30 and a tortuosity
τ of 4.0. The pores are filled with water at 298 K. At one face the concentration of KCl is held at
0.10 g mol/liter, and fresh water flows rapidly past the other face. Neglecting any other
resistance but that in the porous solid, calculate the diffusion of KCl at steady state.

S olu t ion: The diffusivity of KCl in water from Table 6.3-1 is DAB = 1.87 × 10−9 m2/s. Also, cA1

= 0.10/1000 = 1.0 × 10−4 g mol/cm3 = 0.10 kg mol/m3, and cA2 = 0. Substituting into Eq.
(6.5-13),
2. Diffu sion of g a ses in p or ou s solid s

If the voids shown in Fig. 6.5-2 are filled with gases, then a somewhat similar situation exists. If the
pores are very large so that diffusion occurs only by Fickian-type diffusion, then Eq. (6.5-13) becomes, for
gases,

Equation 6.5-15

Again the value of the tortuosity must be determined experimentally. Diffusion is assumed to occur only
through the voids or pores and not through the actual solid particles.

A correlation of tortuosity versus the void fraction of various unconsolidated porous media of beds of
glass spheres, sand, salt, talc, and so on (S8) gives the following approximate values of τ for different
values of ε: ε = 0.2, τ = 2.0; ε = 0.4, τ = 1.75; ε = 0.6, τ = 1.65.

When the pores are quite small in size and on the order of magnitude of the mean free path of the gas,
other types of diffusion occur, which are discussed in Section 7.6.
                             
                                                 
                                             
                                               
     

6.6. NUMERICAL METHODS FOR STEADY­STATE MOLECULAR
DIFFUSION IN TWO DIMENSIONS

6 .6 A. De r iv ation of Eq u ations for  Nu m e r ical M e thod s

1. Der iv a t ion of met ho d s for  st ea d y  st a t e

In Fig. 6.6-1 a two-dimensional solid shown with unit thickness is divided into squares. The numerical
methods for steady-state molecular diffusion are very similar to those for steady-state heat conduction
discussed in Section 4.15. Hence, only a brief summary will be given here. The solid inside of a square is
imagined to be concentrated at the center of the square at cn,m and is called a “node”, which is connected
to adjacent nodes by connecting rods through which the mass diffuses.

Figure 6.6-1. Concentr ations and spacing of nodes for two-dimensional steady-state molecular diffu sion.

A total mass balance is made at steady state by stating that the sum of the molecular diffusion to the
shaded area for unit thickness must equal zero:

Equation 6.6-1

[View full size image]

where cn,m is concentration of A at node n,m in kg mol A/m3. Setting Δx = Δy, and rearranging,

Equation 6.6-2
2. It er a t ion met hod  of nu mer ica l solu t ion

In order to solve Eq. (6.6-2), a separate equation is written for each unknown point giving N linear
algebraic equations for N unknown points. For a hand calculation using a modest number of nodes, the
iteration method can be used to solve the equations, where the right-hand side of Eq. (6.6-2) is set equal

to a residual  :

Equation 6.6-3

Setting the equation equal to zero,   = 0 for steady state and cn,m is calculated by

Equation 6.6-4

Equations (6.6-3) and (6.6-4) are the final equations to be used to calculate all the concentrations at
steady state.

Example 4.15-1 for steady-state heat conduction illustrates the detailed steps for the iteration method,
which are identical to those for steady-state diffusion.

Once the concentrations have been calculated, the flux can be calculated for each element as follows.
Referring to Fig. 6.6-1, the flux for the node or element cn,m to cn,m−1 is (Δx = Δy)

Equation 6.6-5

where the area A is Δx times 1 m deep and N is kg mol A/s. Equations are written for the other
appropriate elements and the sum of the fluxes calculated. This numerical method is well suited for use
with a computer spreadsheet.

6 .6 B. Eq u ations for  S p e cial Bou nd ar y C ond itions for  Nu m e r ical M e thod

1. Eq u a t ions for  b ou nd a r y  cond it ions

When one of the nodal points cn,m is at a boundary where convective mass transfer is occurring to a
constant concentration c∞ in the bulk fluid shown in Fig. 6.6-2a, a different equation must be derived.
Making a mass balance on the node n, m, where mass in = mass out at steady state,

Equation 6.6-6

Figure 6.6-2. Different boundary conditions for steady-state diffusion: (a) convection at a boundary, (b)
insulated boundary, (c) exterior corner with convective boundary, (d) interior corner with convective
boundary.

where kc is the convective mass-transfer coefficient in m/s defined by Eq. (6.1-14).

Setting Δx = Δy, rearranging, and setting the resultant equation equal to  , the residual, the
following results:

1.  For convection at a boundary (Fig. 6.6-2a),

Equation 6.6-7
This equation is similar to Eq. (4.15-16) for heat conduction and convection, with kc Δx/DAB being
used in place of h Δx/k. Similarly, Eqs. (6.6-8)–(6.6-10) have been derived for the other boundary
conditions shown in Fig. 6.6-2.

2.  For an insulated boundary (Fig. 6.6-2b),

Equation 6.6-8

3.  For an exterior corner with convection at the boundary (Fig. 6.6-2c),

Equation 6.6-9

4.  For an interior corner with convection at the boundary (Fig. 6.6-2d),

Equation 6.6-10

2. Bou nd a r y  cond it ions w it h d ist r ib u t ion coefficient

When Eq. (6.6-7) was derived, the distribution coefficient K between the liquid and the solid at the
surface interface was 1.0. The distribution coefficient as shown in Fig. 6.6-3 is defined as

Equation 6.6-11

Figure 6.6-3. Interface concentrations for convective mass transfer at a solid surface and an equilibrium
distribution coefficient K =×c n,mL /c n,m .
where cn,mL is the concentration in the liquid adjacent to the surface and cn,m is the concentration in the
solid adjacent to the surface. Then in deriving Eq. (6.6-6), the right-hand side kc Δy(cn,m − c∞) becomes

Equation 6.6-12

where c∞ is the concentration in the bulk fluid. Substituting Kcn,m for cn,mL from Eq. (6.6-11) into (6.6-
12) and multiplying and dividing by K,

Equation 6.6-13

Hence, whenever kc appears as in Eq. (6.6-7), Kkc should be substituted, and when c∞ appears, c∞/K
should be used. Then Eq. (6.6-7) becomes as follows:

1.  For convection at a boundary (Fig. 6.6-2a),

Equation 6.6-14

[View full size image]

Equations (6.6-9) and (6.6-10) can be rewritten in a similar manner as follows:

2.  For an exterior corner with convection at the boundary (Fig. 6.6-2c),

Equation 6.6-15

3.  For an interior corner with convection at the boundary (Fig. 6.6-2d),

Equation 6.6-16
[View full size image]

EXAMPLE 6.6-1. Numerical Method for Convection and
Steady-State Diffusion
For the two-dimensional hollow solid chamber shown in Fig. 6.6-4, determine the
concentrations at the nodes as shown at steady state. At the inside surfaces the concentrations
remain constant at 6.00 × 10−3 kg mol/m3. At the outside surfaces the convection coefficient
kc = 2 × 10−7  m/s and c∞ = 2.00 × 10−3 kg mol/m3. The diffusivity in the solid is DAB = 1.0 ×

10−9 m2/s. The grid size is Δx = Δy = 0.005 m. Also, determine the diffusion rates per 1.0 m
depth. The distribution coefficient K = 1.0.

Figure 6.6-4. Concentrations for hollow chamber for Example 6.6-1.

S olu t ion: To simplify the calculations, all the concentrations will be multiplied by 103. Since

the chamber is symmetrical, we do the calculations on the   shaded portion shown. The fixed
known values are c1,3 = 6.00, c1,4 = 6.00, c∞ = 2.00. Because of symmetry, c1,2 = c2,3, c2,5 =
c2,3, c2,1 = c3,2, c3,3 = c3,5. To speed up the calculations, we will make estimates of the
unknown concentrations as follows: c2,2 = 3.80, c2,3 = 4.20, c2,4 = 4.40, c3,1 = 2.50, c3,2 =
2.70, c3,3 = 3.00, c3,4 = 3.20.

For the interior points c2,2, c2,3, and c2,4 we use Eqs. (6.6-3) and (6.6-4); for the corner
convection point c3,1, Eq. (6.6-9); for the other convection points c3,2, c3,3, c3,4, Eq. (6.6-7).

The term kc Δx/DAB = (2 × 10−7 )(0.005)/(1.0 × 10−9) = 1.00.
First approximation. Starting with c2,2 we use Eq. (6.6-3) and calculate the residual  :

Hence, c2,2 is not at steady state. Next we set   equal to zero and calculate a new value of
c2,2 from Eq. (6.6-4):

This new value of c2,2 replaces the old value.

For c2,3,

For c2,4,

For c3,1, we use Eq. (6.6-9):

Setting Eq. (6.6-9) equal to zero and solving for c3,1,
For c3,2, we use Eq. (6.6-7):

For c3,3,

For c3,4,

Having completed one sweep across the grid map, we can perform a second approximation
using the new values calculated, starting with c2,2 or any other node. We continue until all the
residuals are as small as desired. The final values after three approximations are c2,2 = 3.47,
c2,3 = 4.24, c2,4 = 4.41, c3,1 = 2.36, c3,2 = 2.72, c3,3 = 3.06, c3,4 = 3.16.

To calculate the diffusion rates we first calculate the total convective diffusion rate, leaving the
bottom surface at nodes c3,1, c3,2, c3,3, and c3,4 for 1.0 m depth:

Note that the first and fourth paths include only one-half of a surface. Next we calculate the
total diffusion rate in the solid entering the top surface inside, using an equation similar to Eq.
(6.6-5):

At steady state the diffusion rate leaving by convection should equal that entering by
diffusion. These results indicate a reasonable check. Using smaller grids would give even more
accuracy. Note that the results for the diffusion rate should be multiplied by 8.0 for the whole
chamber.
                             
                                                 
                                             
                                               
     

PROBLEMS
6 .1-1.
Diffu sion of M et ha ne Thr ou g h Heliu m. A gas of CH4 and He is contained in a tube at
101.32 kPa pressure and 298 K. At one point the partial pressure of methane is pA1 = 60.79 kPa,
and at a point 0.02 m distance away, pA2 = 20.26 kPa. If the total pressure is constant
throughout the tube, calculate the flux of CH4 (methane) at steady state for equimolar
counterdiffusion.
A1:  

Ans.
6 .1-2.
Diffu sion of C O 2  in a  Bina r y  G a s M ixt u r e. The gas CO2 is diffusing at steady state
through a tube 0.20 m long having a diameter of 0.01 m and containing N2 at 298 K. The total
pressure is constant at 101.32 kPa. The partial pressure of CO2 is 456 mm Hg at one end and 76

mm Hg at the other end. The diffusivity DAB is 1.67 × 10−5 m2/s at 298 K. Calculate the flux of
CO2 in cgs and SI units for equimolar counterdiffusion.
6 .2-1.
Eq u imola r  C ou nt er d iffu sion of a  Bina r y  G a s M ixt u r e. Helium and nitrogen gas are
contained in a conduit 5 mm in diameter and 0.1 m long at 298 K and a uniform constant
pressure of 1.0 atm abs. The partial pressure of He at one end of the tube is 0.060 atm and at the
other end is 0.020 atm. The diffusivity can be obtained from Table 6.2-1. Calculate the following
for steady-state equimolar counterdiffusion:

a.  Flux of He in kg mol/s · m2 and g mol/s · cm2.

b.  Flux of N2.

c.  Partial pressure of He at a point 0.05 m from either end.

6 .2-2.
Eq u imola r  C ou nt er d iffu sion of NH 3  a nd  N 2  a t  S t ea d y  S t a t e. Ammonia gas (A) and
nitrogen gas (B) are diffusing in counterdiffusion through a straight glass tube 2.0 ft (0.610 m)
long with an inside diameter of 0.080 ft (24.4 mm) at 298 K and 101.32 kPa. Both ends of the
tube are connected to large mixed chambers at 101.32 kPa. The partial pressure of NH3 is
constant at 20.0 kPa in one chamber and 6.666 kPa in the other. The diffusivity at 298 K and
101.32 kPa is 2.30 × 10−5 m2/s.

a.  Calculate the diffusion of NH3 in lb mol/h and kg mol/s.

b.  Calculate the diffusion of N2.

c.  Calculate the partial pressures at a point 1.0 ft (0.305 m) in the tube and plot ρA, ρB, and
P versus distance z.
A4 : Ans.  (a) Diffusion of NH  = 7.52 × 10−7  lb mol A/h, 9.48 × 10−11 kg mol A/s; (c) ρ  = 1.333 × 104
3 A
Pa
6 .2-3.
Diffu sion of A Thr ou g h S t a g na nt  B a nd  Effect  of Ty p e of Bou nd a r y  on Flu x.
Ammonia gas is diffusing through N2 under steady-state conditions with N2 nondiffusing since

it is insoluble in one boundary. The total pressure is 1.013 × 105 Pa and the temperature is 298
K. The partial pressure of NH3 at one point is 1.333 × 104 Pa, and at the other point 20 mm away

it is 6.666 × 103 Pa. The DAB for the mixture at 1.013 × 105 Pa and 298 K is 2.30 × 10−5 m2/s.

a.  Calculate the flux of NH3 in kg mol/s · m2.

b.  Do the same as (a) but assume that N2 also diffuses; that is, both boundaries are
permeable to both gases and the flux is equimolar counterdiffusion. In which case is the
flux greater?

A5: Ans.  (a) N  = 3.44 × 10−6 kg mol/s · m2


A
6 .2-4 .
Diffu sion of M et ha ne Thr ou g h Nond iffu sing  Heliu m. Methane gas is diffusing in a
straight tube 0.1 m long containing helium at 298 K and a total pressure of 1.01325 × 105 Pa.
The partial pressure of CH4 is 1.400 × 104 Pa at one end and 1.333 × 103 Pa at the other end.
Helium is insoluble in one boundary, and hence is nondiffusing or stagnant. The diffusivity is
given in Table 6.2-1. Calculate the flux of methane in kg mol/sm2 at steady state.
6 .2-5.
M a ss Tr a nsfer  fr om a  Na p ht ha lene S p her e t o Air . Mass transfer is occurring from a
sphere of naphthalene having a radius of 10 mm. The sphere is in a large volume of still air at
52.6°C and 1 atm abs pressure. The vapor pressure of naphthalene at 52.6°C is 1.0 mm Hg. The
diffusivity of naphthalene in air at 0°C is 5.16 × 10−6 m2/s. Calculate the rate of evaporation of
naphthalene from the surface in kg mol/s · m2. [Note: The diffusivity can be corrected for
temperature using the temperature-correction factor from the Fuller et al. equation (6.2-45).]
6 .2-6 .
Est ima t ion of Diffu siv it y  of a  Bina r y  G a s. For a mixture of ethanol (CH3CH2OH) vapor
and methane (CH4), predict the diffusivity using the method of Fuller et al.

a.  At 1.0132 × 105 Pa and 298 and 373 K.

b.  At 2.0265 × 105 Pa and 298 K.

A8: Ans.  (a) D  = 1.43 × 10−5 m2/s (298 K)


AB
6 .2-7.
Diffu sion Flu x a nd  Effect  of Temp er a t u r e a nd  Pr essu r e. Equimolar counterdiffusion is
occurring at steady state in a tube 0.11 m long containing N2 and CO gases at a total pressure of
1.0 atm abs. The partial pressure of N2 is 80 mm Hg at one end and 10 mm at the other end.
Predict the DAB by the method of Fuller et al.

a.  Calculate the flux in kg mol/s · m2 at 298 K for N2.
b.  Repeat at 473 K. Does the flux increase?

c.  Repeat at 298 K but for a total pressure of 3.0 atm abs. The partial pressure of N2 remains
at 80 and 10 mm Hg, as in part (a). Does the flux change?

A9 : Ans.  (a) D  = 2.05 × 10−5 m2/s, N  = 7.02 × 10−7  kg mol/s · m2; (b) N  = 9.92 × 10−7  kg mol/s


AB A A
· m2; (c) N  = 2.34 × 10−7  kg mol/s · m2
A
6 .2-8.
Ev a p or a t ion Losses of W a t er  in Ir r ig a t ion Dit ch. Water at 25°C is flowing in a covered
irrigation ditch below ground. Every 100 ft there is a vent line 1.0 in. inside diameter and 1.0 ft
long to the outside atmosphere at 25°C. There are 10 vents in the 1000-ft ditch. The outside air
can be assumed to be dry. Calculate the total evaporation loss of water in lbm/d. Assume that
the partial pressure of water vapor at the surface of the water is the vapor pressure, 23.76 mm Hg
at 25°C. Use the diffusivity from Table 6.2-1.
6 .2-9 .
Time t o C omp let ely  Ev a p or a t e a  S p her e. A drop of liquid toluene is kept at a uniform
temperature of 25.9°C and is suspended in air by a fine wire. The initial radius r 1 = 2.00 mm.
The vapor pressure of toluene at 25.9°C is PA1 = 3.84 kPa and the density of liquid toluene is 866

kg/m3.

a.  Derive Eq. (6.2-34) to predict the time t F for the drop to evaporate completely in a large


volume of still air. Show all steps.

b.  Calculate the time in seconds for complete evaporation.

A11:Ans. (b) t F = 1388 s
6 .2-10.
Diffu sion in a  Nonu nifor m C r oss-S ect iona l Ar ea . The gas ammonia (A) is diffusing at
steady state through N2 (B) by equimolar counterdiffusion in a conduit 1.22 m long at 25°C and
a total pressure of 101.32 kPa abs. The partial pressure of ammonia at the left end is 25.33 kPa
and at the other end 5.066 kPa. The cross section of the conduit is in the shape of an equilateral
triangle, the length of each side of the triangle being 0.0610 m at the left end and tapering
uniformally to 0.0305 m at the right end. Calculate the molar flux of ammonia. The diffusivity is
DAB = 0.230 × 10−4 m2/s.

6 .3-1.
Diffu sion of A Thr ou g h S t a g na nt  B in a  Liq u id . The solute HCl (A) is diffusing through a
thin film of water (B) 2.0 mm thick at 283 K. The concentration of HCl at point 1 at one
boundary of the film is 12.0 wt % HCl (density ρ1 = 1060.7 kg/m3), and at the other boundary at

point 2 it is 6.0 wt % HCl (ρ2 = 1030.3 kg/m3). The diffusion coefficient of HCl in water is 2.5 ×

10−9 m2/s. Assuming steady state and one boundary impermeable to water, calculate the flux of
HCl in kg mol/s · m2.
A13: Ans.  N  = 2.372 × 10−6 kg mol/s · m2
A
6 .3-2.
Diffu sion of Ammonia  in a n Aq u eou s S olu t ion. An ammonia (A)–water (B) solution at
278 K and 4.0 mm thick is in contact at one surface with an organic liquid at this interface. The
concentration of ammonia in the organic phase is held constant and is such that the equilibrium
concentration of ammonia in the water at this surface is 2.0 wt % ammonia (density of aqueous
solution 991.7 kg/m3) and the concentration of ammonia in water at the other end of the film
4.0 mm away is 10 wt % (density 961.7 kg/m3). Water and the organic are insoluble in each
other. The diffusion coefficient of NH3 in water is 1.24 × 10−9 m2/s.

a.  At steady state, calculate the flux NA in kg mol/s·m2.

b.  Calculate the flux NB. Explain.

6 .3-3.
Est ima t ion of Liq u id  Diffu siv it y . It is desired to predict the diffusion coefficient of dilute
acetic acid (CH3COOH) in water at 282.9 K and at 298 K using the Wilke–Chang method.
Compare the predicted values with the experimental values in Table 6.3-1.
A15: Ans.  D  = 0.897 × 10−9 m2/s (282.9 K), D  = 1.396 × 10−9 m2/s (288 K)
AB AB
6 .3-4 .
Est ima t ion of Diffu siv it y  of M et ha nol in H 2 O. The diffusivity of dilute methanol in water

has been determined experimentally to be 1.26 × 10−9 m2/s at 288 K.

a.  Estimate the diffusivity at 293 K using the Wilke–Chang equation.

b.  Estimate the diffusivity at 293 K by correcting the experimental value at 288 K to 293 K.
(Hint: Do this by using the relationship DAB ∝ T/μB.)

6 .3-5.
Est ima t ion of Diffu siv it y  of Elect r oly t e Na OH. Dilute NaOH is diffusing in an aqueous
solution. Do as follows:

a.  Estimate the diffusivity of NaOH at 25°C. Also, calculate the diffusivity of the individual
ions Na+ and OH−.

b.  Estimate the diffusivity of NaOH at 15°C.

A17:  

Ans.
6 .3.6 .
Est ima t ion of Diffu siv it y  of La C l 3  a nd  Temp er a t u r e Effect . Estimate the diffusion
coefficient of the salt LaCl3 in dilute aqueous solution at 25°C and at 35°C. Also, calculate the

diffusion coefficient for the ions La3+ and Cl− at 25°C. What percent increase in rate of diffusion
will occur in going from 25 to 35°C if the same dilute concentration difference is present at both
temperatures?
A18:  

Ans.
6 .4 -1.
Pr ed ict ion of Diffu siv it y  of Enzy me Ur ea se in S olu t ion. Predict the diffusivity of the
enzyme urease in a dilute solution in water at 298 K using the modified Polson equation and
compare the result with the experimental value in Table 6.4-1.
A19 : Ans.  Predicted D  = 3.995 × 10−11 m2/s
AB
6 .4 -2.
Diffu sion of S u cr ose in G ela t in. A layer of gelatin in water 5 mm thick containing 5.1 wt %
gelatin at 293 K separates two solutions of sucrose. The concentration of sucrose in the solution
at one surface of the gelatin is constant at 2.0 g sucrose/100 mL solution, and 0.2 g/100 mL at
the other surface. Calculate the flux of sucrose in kg sucrose/s·m2 through the gel at steady state.
6 .4 -3.
Diffu siv it y  of Oxy g en in Pr ot ein S olu t ion. Oxygen is diffusing through a solution of
bovine serum albumin (BSA) at 298 K. Oxygen has been shown not to bind to BSA. Predict the
diffusivity DAP of oxygen in a protein solution containing 11 g protein/100 mL solution. (Note:
See Table 6.3-1 for the diffusivity of O2 in water.)
A21: Ans.  D  = 1.930 × 10−9 m2/s
AP
6 .4 -4 .
Diffu sion of Ur ic Acid  in Pr ot ein S olu t ion a nd  Bind ing . Uric acid (A) at 37°C is diffusing
in an aqueous solution of proteins (P) containing 8.2 g protein/100 mL solution. Uric acid binds
to the proteins, and over the range of concentrations present, 1.0 g mol of acid binds to the
proteins for every 3.0 g mol of total acid present in the solution. The diffusivity DAB of uric acid

in water is 1.21 × 10−5 cm2/s and DP = 0.091 × 10−5 cm2/s.

a.  Assuming no binding, predict the ratio DAP/DAB due only to blockage effects.

b.  Assuming blockage plus binding effects, predict the ratio DAP/DAB. Compare this with
the experimental value for DAP/DAB of 0.616 (C8).

c.  Predict the flux in g uric acid/s.·.cm2 for a concentration of acid of 0.05 g/L at point (1)
and 0 g/L at point (2) a distance 1.5 μm away.

A22: Ans.  (c) N  = 2.392 × 10−6 g/s · cm2


A
6 .5-1.
Diffu sion of C O 2  Thr ou g h R u b b er . A flat plug 30 mm thick having an area of 4.0 × 10−4 m2
and made of vulcanized rubber is used for closing an opening in a container. The gas CO2 at 25°C
and 2.0 atm pressure is inside the container. Calculate the total leakage or diffusion of CO2
through the plug to the outside in kg mol CO2/s at steady state. Assume that the partial

pressure of CO2 outside is zero. From Barrer (B5) the solubility of the CO2 gas is 0.90 m3 gas (at

STP of 0°C and 1 atm) per m3 rubber per atm pressure of CO2. The diffusivity is 0.11 × 10−9

m2/s.
A23: Ans.  1.178 × 10−13 kg mol CO /s
2
6 .5-2.
Lea k a g e of Hy d r og en Thr ou g h Neop r ene R u b b er . Pure hydrogen gas at 2.0 atm abs
pressure and 27°C is flowing past a vulcanized neoprene rubber slab 5 mm thick. Using the data
from Table 6.5-1, calculate the diffusion flux in kg mol/s · m2 at steady state. Assume no
resistance to diffusion outside the slab and zero partial pressure of H2 on the outside.
6 .5-3.
R ela t ion Bet w een Diffu siv it y  a nd  Per mea b ilit y . The gas hydrogen is diffusing through a
sheet of vulcanized rubber 20 mm thick at 25°C. The partial pressure of H2 is 1.5 atm inside and
0 outside. Using the data from Table 6.5-1, calculate the following:

a.  The diffusivity DAB from the permeability PM and solubility S, and compare with the
value in Table 6.5-1.
b.  The flux NA of H2 at steady state.

A25: Ans.  (b) N  = 1.144 × 10−10 kg mol/s · m2


A
6 .5-4 .
Loss fr om a  Tu b e of Neop r ene. Hydrogen gas at 2.0 atm and 27°C is flowing in a neoprene
tube 3.0 mm inside diameter and 11 mm outside diameter. Calculate the leakage of H2 through a
tube 1.0 m long in kg mol H2/s at steady state.
6 .5-5.
Diffu sion Thr ou g h M emb r a nes in S er ies. Nitrogen gas at 2.0 atm and 30°C is diffusing
through a membrane of nylon 1.0 mm thick and polyethylene 8.0 mm thick in series. The partial
pressure at the other side of the two films is 0 atm. Assuming no other resistances, calculate the
flux NA at steady state.
6 .5-6 .
Diffu sion of C O 2  in a  Pa ck ed  Bed  of S a nd . It is desired to calculate the rate of diffusion of
CO2 gas in air at steady state through a loosely packed bed of sand at 276 K and a total pressure

of 1.013 × 105 Pa. The bed depth is 1.25 m and the void fraction ε is 0.30. The partial pressure of
CO2 is 2.026 × 103 Pa at the top of the bed and 0 Pa at the bottom. Use a τ of 1.87.
A28: Ans.  N  = 1.609 × 10−9 kg mol CO /s · m2
A 2
6 .5-7.
Pa ck a g ing  t o K eep  Food  M oist . Cellophane is being used to keep food moist at 38°C.
Calculate the loss of water vapor in g/d at steady state for a wrapping 0.10 mm thick and an area
of 0.200 m2 when the vapor pressure of water vapor inside is 10 mm Hg and the air outside
contains water vapor at a pressure of 5 mm Hg. Use the larger permeability in Table 6.5-1.
A29 :Ans. 0.1663 g H2O/day.
6 .5-8.
Loss of Heliu m a nd  Per mea b ilit y . A window of SiO2 2.0 mm thick and 1.0 × 10−4 m2 in
area is used to view the contents in a metal vessel at 20°C. Helium gas at 202.6 kPa is contained
in the vessel. To be conservative use DAB = 5.5 × 10−14 m2/s from Table 6.5-1.

a.  Calculate the loss of He in kg mol/h at steady state.

b.  Calculate the permeability PM.

A30: Ans.  (a) Loss = 8.833 × 10−15 kg mol He/h


6 .6 -1.
Nu mer ica l M et hod  for  S t ea d y -S t a t e Diffu sion. Using the results from Example 6.6-1,
calculate the total diffusion rate in the solid using the bottom nodes and paths of c2,2 to c3,2, c2,3
to c3,3, and so on. Compare with the other diffusion rates in Example 6.6-1.
A31: Ans.  N = 2.555 × 10−12 kg mol/s
6 .6 -2.
Nu mer ica l M et hod  for  S t ea d y -S t a t e Diffu sion w it h Dist r ib u t ion C oefficient . Use the
conditions given in Example 6.6-1 except that the distribution coefficient defined by Eq. (6.6-11)
between the concentration in the liquid adjacent to the external surface and the concentration in
the solid adjacent to the external surface is K = 1.2. Calculate the steady-state concentrations
and the diffusion rates.
6 .6 -3.
S p r ea d sheet  S olu t ion for  S t ea d y -S t a t e Diffu sion. Use the conditions given in Example
6.6-1 but instead of using Δx = 0.005 m, use Δx = Δy = 0.001 m. The overall dimensions of the
hollow chamber remain as in Example 6.6-1; the only difference is that more nodes will be used.
Write the spreadsheet program and solve for the steady-state concentrations using the
numerical method. Also, calculate the diffusion rates and compare with Example 6.6-1.

6 .6 -4 .
Nu mer ica l M et hod  w it h Fixed  S u r fa ce C oncent r a t ions. Steady-state diffusion is
occurring in a two-dimensional solid as shown in Fig. 6.6-4. The grid Δx = Δy = 0.010 m. The
diffusivity DAB = 2.00 × 10−9 m2/s. At the inside of the chamber the surface concentration is

held constant at 2.00 × 10−3 kg mol/m3. At the outside surfaces, the concentration is constant
at 8.00 × 10−3. Calculate the steady-state concentrations and the diffusion rates per m of depth.
                             
                                                 
                                             
                                               
     

Chapter 7. Principles of Unsteady­State and Convective
Mass Transfer
                             
                                                 
                                             
                                               
     

7.1. UNSTEADY­STATE DIFFUSION

7.1A. De r iv ation of Basic Eq u ation

In Chapter 6 we considered various mass-transfer systems where the concentration or partial pressure at
any point and the diffusion flux were constant with time, hence at steady state. Before steady state can
be reached, time must elapse after the mass-transfer process is initiated for the unsteady-state
conditions to disappear.

In Section 2.3 a general property balance for unsteady-state molecular diffusion was made for the
properties momentum, heat, and mass. For no generation present, this was

Equation 2.13-12

In Section 5.1 an unsteady-state equation for heat conduction was derived,

Equation 5.1-10

The derivation of the unsteady-state diffusion equation in one direction for mass transfer is similar to
that performed for heat transfer in obtaining Eq. (5.1-10). We refer to Fig. 7.1-1, where mass is diffusing
in the x direction in a cube composed of a solid, stagnant gas, or stagnant liquid and having dimensions
Δx, Δy, Δz. For diffusion in the x direction we write

Equation 7.1-1

Figure 7.1-1. Unsteady-state diffu sion in one direction.
The term ∂cA/∂x means the partial of cA with respect to x or the rate of change of cA with x when the other
variable, time t, is kept constant.

Next we make a mass balance on component A in terms of moles for no generation:

Equation 7.1-2

The rate of input and rate of output in kg mol A/s are

Equation 7.1-3

Equation 7.1-4

The rate of accumulation is as follows for the volume Δx Δy Δz m3:

Equation 7.1-5

Substituting Eqs. (7.1-3), (7.1-4), and (7.1-5) into (7.1-2) and dividing by Δx Δy Δz,

Equation 7.1-6
Letting Δx approach zero,

Equation 7.1-7

The above holds for a constant diffusivity DAB. If DAB is a variable,

Equation 7.1-8

Equation (7.1-7) relates the concentration cA with position x and time t. For diffusion in all three
directions a similar derivation gives

Equation 7.1-9

In the remainder of this section, the solutions of Eqs. (7.1-7) and (7.1-9) will be considered. Note the
mathematical similarity between the equation for heat conduction,

Equation 5.1-6

and Eq. (7.1-7) for diffusion. Because of this similarity, the mathematical methods used for solution of
the unsteady-state heat-conduction equation can be used for unsteady-state mass transfer. This is
discussed more fully in Sections 7.1B, 7.1C, and 7.7.

7.1B. Diffu sion in a Flat Plate  w ith Ne gligib le  S u r face  R e sistance

To illustrate an analytical method of solving Eq. (7.1-7), we will derive the solution for unsteady-state
diffusion in the x direction for a plate of thickness 2x1, as shown in Fig. 7.1-2. For diffusion in one
direction,
Equation 7.1-7

Figure 7.1-2. Unsteady-state diffusion in a flat plate with negligible surface resistance.

Dropping the subscripts A and B for convenience,

Equation 7.1-10

The initial profile of the concentration in the plate at t = 0 is uniform at c = c0 for all x values, as shown
in Fig. 7.1-2. At time t = 0 the concentration of the fluid in the environment outside is suddenly changed
to c1. For a very high mass-transfer coefficient outside the surface resistance will be negligible and the
concentration at the surface will be equal to that in the fluid, which is c1.

The initial and boundary conditions are

Equation 7.1-11
Redefining the concentration so it goes between 0 and 1,

Equation 7.1-12

Equation 7.1-13

The solution of Eq. (7.1-13) is an infinite Fourier series and is identical to the solution of Eq. (5.1-6) for
heat transfer:

Equation 7.1-14

where

, dimensionless

c = concentration at point x and time t in slab
Y = (c1 -c)/(c1 -c0 ) = fraction of unaccomplished change, dimensionless

1-Y = (c-c0 )/(c1 -c0 ) = fraction of change

Solution of equations similar to Eq. (7.1-14) are time-consuming; convenient charts for various
geometries are available and will be discussed in the next section.

7.1C . Unste ad y-S tate  Diffu sion in Var iou s G e om e tr ie s


1. C onv ect ion a nd  b ou nd a r y  cond it ions a t  t he su r fa ce

In Fig. 7.1-2 there was no convective resistance at the surface. However, in many cases when a fluid is
outside the solid, convective mass transfer is occurring at the surface. A convective mass-transfer
coefficient kc, similar to a convective heat-transfer coefficient, is defined as follows:

Equation 7.1-15

where kc is a mass-transfer coefficient in m/s, cL1 is the bulk fluid concentration in kg mol A/m3, and cLi
is the concentration in the fluid just adjacent to the surface of the solid. The coefficient kc is an empirical
coefficient and will be discussed more fully in Section 7.2.

In Fig. 7.1-3a the case where a mass-transfer coefficient is present at the boundary is shown. The
concentration drop across the fluid is cL1 − cLi. The concentration in the solid ci at the surface is in
equilibrium with cLi.

Figure 7.1-3. Interface conditions for convective mass transfer and an equilibrium distribution coefficient K
=c Li /c i : (a) K = 1. (b) K > 1, (c) K < 1, (d) K > 1 and k c  = ∞.

In Fig. 7.1-3a the concentration cLi in the liquid adjacent to the solid and ci in the solid at the surface are
in equilibrium and are equal. However, unlike heat transfer, where the temperatures are equal, the
concentrations here are in equilibrium and are related by

Equation 7.1-16
where K is the equilibrium distribution coefficient (similar to Henry's law coefficient for a gas and liquid).
The value of K in Fig. 7.1-3a is 1.0.

In Fig. 7.1-3b the distribution coefficient K > 1 and cLi > ci, even though they are in equilibrium. Other
cases are shown in Fig. 7.1-3c and d. This was also discussed in Section 6.6B.

2. R ela t ion b et w een ma ss- a nd  hea t -t r a nsfer  p a r a met er s

In order to use the unsteady-state heat-conduction charts in Chapter 5 for solving unsteady-state
diffusion problems, the dimensionless variables or parameters for heat transfer must be related to those
for mass transfer. In Table 7.1-1 the relations between these variables are tabulated. For K ≠ 1.0, whenever
kc appears, it is given as Kkc, and whenever c1 appears, it is given as c1/K.

Table 7.1-1. Relation Between Mass- and Heat-Transfer Parameters for Unsteady-State
Diffusion[*]

  Mass Transfer

Heat Transfer K = c L /c = 1.0 K = c L /c ≠ 1.0

[*]
 x is the distance from the center of the slab, cylinder, or sphere; for a semi-infinite slab, x is the distance from the surface, c0
is the original uniform concentration in the solid, c1 the concentration in the fluid outside the slab, and c the concentration in the
solid at position x and time t.

3. C ha r t s for  d iffu sion in v a r iou s g eomet r ies


The various heat-transfer charts for unsteady-state conduction can be used for unsteady-state diffusion
and are as follows:

1.  Semi-infinite solid, Fig. 5.3-3.

2.  Flat plate, Figs. 5.3-5 and 5.3-6.

3.  Long cylinder, Figs. 5.3-7 and 5.3-8.

4.  Sphere, Figs. 5.3-9 and 5.3-10.

5.  Average concentrations, zero convective resistance, Fig. 5.3-13.

EXAMPLE 7.1-1. Unsteady-State Diffusion in a Slab of
Agar Gel
A solid slab of 5.15 wt % agar gel at 278 K is 10.16 mm thick and contains a uniform
concentrations of urea of 0.1 kg mol/m3. Diffusion is only in the x direction through two
parallel flat surfaces 10.16 mm apart. The slab is suddenly immersed in pure turbulent water,
so the surface resistance can be assumed to be negligible; that is, the convective coefficient kc is

very large. The diffusivity of urea in the agar from Table 6.4-2 is 4.72 × 10−10 m2/s.

a.  Calculate the concentration at the midpoint of the slab (5.08 mm from the surface) and
2.54 mm from the surface after 10 h.

b.  If the thickness of the slab is halved, what would be the midpoint concentration in 10 h?

S olu t ion: For part (a), c0 = 0.10 kg mol/m3, c1 = 0 for pure water, and c = concentration at
distance x from center line and time t s. The equilibrium distribution coefficient K in Eq. (7.1-
16) can be assumed to be 1.0, since the water in the aqueous solution in the gel and outside
should be very similar in properties. From Table 7.1-1,

Also, x1 = 10.16/(1000 × 2) = 5.08 × 10−3 m (half-slab thickness), x = 0 (center), X = 

 = (4.72 × 10−10)(10 × 3600)/(5.08 × 10−3)2 = 0.658. The relative position n = x/x1

= 0/5.08 × 10−3 = 0, and relative resistance m = DAB/Kkcx1 = 0, since kc is very large (zero
resistance).

From Fig. 5.3-5 for X = 0.658, m = 0, and n = 0,
Solving, c = 0.0275 kg mol/m3 for x = 0.

For the point 2.54 mm from the surface or 2.54 mm from center, x = 2.54/1000 = 2.54 × 10−3
m, X = 0.658, m = 0, n = x/x1 = 2.54 × 10−3/5.08 × 10−3 = 0.5. Then from Fig. 5.3-5, Y =

0.172. Solving, c = 0.0172 kg mol/m3.

For part (b) and half the thickness, X = 0.658/(0.5)2 = 2.632, n = 0, and m = 0. Hence, Y =
0.0020 and c = 2.0 × 10−4 kg mol/m3.

EXAMPLE 7.1-2. Unsteady-State Diffusion in a Semi-
infinite Slab
A very thick slab has a uniform concentration of solute A of c0 = 1.0 × 10−2 kg mol A/m3.
Suddenly, the front face of the slab is exposed to a flowing fluid having a concentration c1 =

0.10 kg mol A/m3 and a convective coefficient kc = 2 × 10−7  m/s. The equilibrium distribution
coefficient K = cLi/ci = 2.0. Assuming that the slab is a semi-infinite solid, calculate the
concentration in the solid at the surface (x = 0) and x = 0.01 m from the surface after t = 3 ×
104 s. The diffusivity in the solid is DAB = 4 × 10−9 m2/s.

S olu t ion: To use Fig. 5.3-3, use Table 7.1-1.

For x = 0.01 m from the surface in the solid,

From the chart, 1 − Y = 0.26. Then, substituting into the equation for (1 − Y) from Table 7.1-1
and solving,

For x = 0 m (i.e., at the surface of the solid),
From the chart, 1 − Y = 0.62. Solving, c = 3.48 × 10−2. This value is the same as ci, as shown in
Fig. 7.1-3b. To calculate the concentration cLi in the liquid at the interface,

A plot of these values will be similar to Fig. 7.1-3b.

4 . Unst ea d y -st a t e d iffu sion in mor e t ha n one d ir ect ion

In Section 5.3F a method was given for unsteady-state heat conduction, in which the one-dimensional
solutions were combined to yield solutions for several-dimensional systems. The same method can be
used for unsteady-state diffusion in more than one direction. Rewriting Eq. (5.3-11) for diffusion in a
rectangular block in the x, y, and z directions,

Equation 7.1-17

where cx,y,z is the concentration at the point x, y, z from the center of the block. The value of Yx for the two
parallel faces is obtained from Fig. 5.3-5 or 5.3-6 for a flat plate in the x direction. The values of Yy  and Yz
are similarly obtained from the same charts. For a short cylinder, an equation similar to Eq. (5.3-12) is
used, and for average concentrations, ones similar to Eqs. (5.3-14), (5.3-15), and (5.3-16) are used.
                             
                                                 
                                             
                                               
     

7.2. CONVECTIVE MASS­TRANSFER COEFFICIENTS

7.2A. Intr od u ction to C onv e ctiv e  M ass Tr ansfe r

In the previous sections of this chapter and in Chapter 6 we have emphasized molecular diffusion in
stagnant fluids or fluids in laminar flow. In many cases the rate of diffusion is slow, and more rapid
transfer is desired. To do this, the fluid velocity is increased until turbulent mass transfer occurs.

To have a fluid in convective flow usually requires the fluid to be flowing past another immiscible fluid or
a solid surface. An example is a fluid flowing in a pipe, where part of the pipe wall is made by a slightly
dissolving solid material such as benzoic acid. The benzoic acid dissolves and is transported
perpendicular to the main stream from the wall. When a fluid is in turbulent flow and is flowing past a
surface, the actual velocity of small particles of fluid cannot be described clearly as in laminar flow. In
laminar flow the fluid flows in streamlines and its behavior can usually be described mathematically.
However, in turbulent motion there are no streamlines; instead there are large eddies or “chunks” of fluid
moving rapidly in seemingly random fashion.

When a solute A is dissolving from a solid surface, there is a high concentration of this solute in the fluid
at the surface, and its concentration, in general, decreases as the distance from the wall increases.
However, minute samples of fluid adjacent to each other do not always have concentrations close to each
other. This occurs because eddies having solute in them move rapidly from one part of the fluid to
another, transferring relatively large amounts of solute. This turbulent diffusion or eddy transfer is quite
fast in comparison to molecular transfer.

Three regions of mass transfer can be visualized. In the first, which is adjacent to the surface, a thin,
viscous sublayer film is present. Most of the mass transfer occurs by molecular diffusion, since few or no
eddies are present. A large concentration drop occurs across this film as a result of the slow diffusion rate.

The transition or buffer region is adjacent to the first region. Some eddies are present, and the mass
transfer is the sum of turbulent and molecular diffusion. There is a gradual transition in this region from
the transfer by mainly molecular diffusion at one end to mainly turbulent at the other end.

In the turbulent region adjacent to the buffer region, most of the transfer is by turbulent diffusion, with a
small amount by molecular diffusion. The concentration decrease is very small here since the eddies tend
to keep the fluid concentration uniform. A more detailed discussion of these three regions is given in
Section 3.10G.

A typical plot for the mass transfer of a dissolving solid from a surface to a turbulent fluid in a conduit is
given in Fig. 7.2-1. The concentration drop from cA1 adjacent to the surface is very abrupt close to the
surface and then levels off. This curve is very similar to the shapes found for heat and momentum

transfer. The average or mixed concentration   is shown and is slightly greater than the minimum cA2.

Figure 7.2-1. Concentr ation profile in turbulent mass tr ansfer fr om a surface to a fluid.


7.2B. Typ e s of M ass-Tr ansfe r  C oe fficie nts

1. Definit ion of ma ss-t r a nsfer  coefficient

Since our understanding of turbulent flow is incomplete, we attempt to write the equations for turbulent
diffusion in a manner similar to that for molecular diffusion. For turbulent mass transfer for constant c,
Eq. (6.1-6) is written as

Equation 7.2-1

where DAB is the molecular diffusivity in m2/s and εM the mass eddy diffusivity in m2/s. The value of εM
is variable and is near zero at the interface or surface and increases as the distance from the wall

increases. We therefore use an average value   since the variation of εM is not generally known.
Integrating Eq. (7.2-1) between points 1 and 2,

Equation 7.2-2

The flux   is based on the surface area A1 since the cross-sectional area may vary. The value of z2 − z1,
the distance of the path, is often not known. Hence, Eq. (7.2-2) is simplified and is written using a
convective mass-transfer coefficient  :

Equation 7.2-3

where   is the flux of A from the surface A1 relative to the whole bulk phase,   is (DAB +  )/(z2 −

z1), an experimental mass-transfer coefficient in kg mol/s · m2 · (kg mol/m3) or simplified as m/s, and

cA2 is the concentration at point 2 in kg mol A/m3 or, more usually, the average bulk concentration 

This definition of a convective mass-transfer coefficient   is quite similar to the convective heat-
transfer coefficient h.

2. M a ss-t r a nsfer  coefficient  for  eq u imola r  cou nt er d iffu sion

Generally, we are interested in NA, the flux of A relative to stationary coordinates. We can start with the
following equation, which is similar to that for molecular diffusion with the term εM added:

Equation 7.2-4

For the case of equimolar counterdiffusion, where NA = −NB, and integrating at steady state, calling 

Equation 7.2-5

Equation (7.2-5) is the defining equation for the mass-transfer coefficient. Often, however, we define the
concentration in terms of mole fraction if a liquid or gas, or in terms of partial pressure if a gas. Hence, we
can define the mass-transfer coefficient in several ways. If y A is mole fraction in a gas phase and xA in a
liquid phase, then Eq. (7.2-5) can be written as follows for equimolar counterdiffusion:

Equation 7.2-6
Equation 7.2-7

All of these mass-transfer coefficients can be related to each other. For example, using Eq. (7.2-6) and
substituting y A1 = cA1/c and y A2 = cA2/c into the equation,

Equation 7.2-8

Hence,

Equation 7.2-9

These relations among mass-transfer coefficients, together with the various flux equations, are given in
Table 7.2-1.

Table 7.2-1. Flux Equations and Mass-Transfer Coefficients

Flux equations for equimolar counterdiffusion

Flux equations for A diffusing through stagnant, nondiffusing B

Conversions between mass-transfer coefficients
Gases:      

Liquids:      

(where ρ is density of liquid and M is molecular weight)
Units of mass-transfer coefficients

  (preferred)    

3. M a ss-t r a nsfer  coefficient  for  A d iffu sing  t hr ou g h st a g na nt , nond iffu sing  B

For A diffusing through stagnant, nondiffusing B, where NB = 0, Eq. (7.2-4) gives for steady state

Equation 7.2-10

where the xBM and its counterpart y BM are similar to Eq. (6.2-21) and kc is the mass-transfer coefficient
for A diffusing through stagnant B. Also,

Equation 7.2-11

Rewriting Eq. (7.2-10) using other units,

Equation 7.2-12

Equation 7.2-13

Again all the mass-transfer coefficients can be related to each other and are given in Table 7.2-1. For
example, setting Eq. (7.2-10) equal to (7.2-13),

Equation 7.2-14
Hence,

Equation 7.2-15

EXAMPLE 7.2-1. Vaporizing A and Convective Mass
Transfer
A large volume of pure gas B at 2 atm pressure is flowing over a surface from which pure A is
vaporizing. The liquid A completely wets the surface, which is a blotting paper. Hence, the
partial pressure of A at the surface is the vapor pressure of A at 298 K, which is 0.20 atm. The 

 has been estimated to be 6.78 × 10−5 kg mol/s · m2 · mol frac. Calculate NA, the
vaporization rate, and also the value of ky  and kG.

S olu t ion: This is the case of A diffusing through B, where the flux of B normal to the surface is
zero, since B is not soluble in liquid A. pA1 = 0.20 atm and pA2 = 0 in the pure gas B. Also, y A1
= pA1/P = 0.20/2.0 = 0.10 and y A2 = 0. We can use Eq. (7.2-12) with mole fractions:

Equation 7.2-12

However, we have a value for   which is related to ky  from Table 7.2-1 by

Equation 7.2-16

The term y BM is similar to xBM and is, from Eq. (7.2-11),

Equation 7.2-11
Substituting into Eq. (7.2-11),

Then, from Eq. (7.2-16),

Also, from Table 7.2-1,

Equation 7.2-17

Hence, solving for kG and substituting knowns,

For the flux, using Eq. (7.2-12),

Also,

Using Eq. (7.2-12) again,
Note that in this case, since the concentrations were dilute, y BM is close to 1.0 and ky  and 
differ very little.

7.2C . M ass Tr ansfe r  C oe fficie nts for  G e ne r al C ase  of A and  B Diffu sing and  C onv e ctiv e
Flow  Using Film  The or y

Equation (7.2-4) can be integrated assuming a simplified film theory where the mass transfer is assumed
to occur through a thin film next to the wall of thickness δf and by molecular diffusion. Then the

experimental value of  for dilute solutions is used to determine the film thickness δf:

Equation 7.2-18

Rewriting Eq. (7.2-4),

Equation 7.2-19

The convective term is xA(NA + NB). Rearranging and integrating,

Equation 7.2-20

Equation 7.2-21
For NB = 0, Eq. (7.2-21) reduces to Eq. (7.2-10).

7.2D. M ass Tr ansfe r  C oe fficie nts u nd e r  High Flu x C ond itions

The final Eq. (7.2-21) is a result of assuming the film theory where molecular diffusion occurs across the
film δf. This assumes that this film thickness is unaffected by high fluxes and bulk or convective flow
(diffusion-induced convection). As a result, other definitions of the mass-transfer coefficient that include
this effect of diffusion-induced convection have been derived. One common method by Bird et al. (B1)
and Skelland (S8) is given as follows for the case of A diffusing through stagnant, nondiffusing B where
diffusion-induced convection is present.

Rewriting Eq. (7.2-19) for the flux NA at the surface z = 0 where xA = xA1,

Equation 7.2-22

Note that the convective term is defined in terms of xA1 and not the average value.

Defining a mass-transfer coefficient in terms of the diffusion flux,

Equation 7.2-23

Substituting Eq. (7.2-23) into (7.2-22) and solving for NA,

Equation 7.2-24

At low concentrations and fluxes,   approaches   for no bulk flow, or 

In general, a coefficient kc may be defined without regard to convective flow:

Equation 7.2-25
Combining (7.2-24) and (7.2-25),

Equation 7.2-26

The relationship between   or kc for high flux and   for low flux will be considered. These corrections


or relationships will be derived using the film theory for the transfer of A by molecular diffusion and
convective flow, with B being stagnant and nondiffusing. This has been done previously and is obtained
by setting NB = 0 in Eq. (7.2-21) to obtain the following, which is identical to Eq. (7.2-10):

Equation 7.2-27

Hence, for the film theory,

Equation 7.2-28

Combining Eqs. (7.2-26) and (7.2-28),

Equation 7.2-29

For this film theory, Eqs. (7.2-28) and (7.2-29) are independent of the Schmidt number. These correction
factors predicted by the film theory give results that are reasonably close to those using more complex
theories—the penetration theory and boundary layer theory— which are discussed later in Section 7.9C.
An advantage of this simple film theory is that it is quite useful in solving complex systems.

EXAMPLE 7.2-2. High Flux Correction Factors
Toluene A is evaporating from a wetted porous slab by having inert pure air at 1 atm flowing
parallel to the flat surface. At a certain point the mass-transfer coefficient   for very low
fluxes has been estimated as 0.20 lb mol/hr · ft 2. The gas composition at the interface at this

point is xA1 = 0.65. Calculate the flux NA and the ratios kc/  or kx/  and  /  or 

 to correct for high flux.

S olu t ion: For the flux NA, using Eq. (7.2-11),

Using Eq. (7.2-10) in terms of   where  ,

Using Eq. (7.2-28),

Then, kx = 1.616   = 1.616(0.20) = 0.323 lb mol/hr · ft 2. Using Eq. (7.2-29),

and   = 0.565(0.200) = 0.113 lb mol/hr · ft 2.

7.2E. M e thod s for  Exp e r im e ntally De te r m ining M ass-Tr ansfe r  C oe fficie nts

Many different experimental methods have been employed to obtain mass-transfer coefficients. In
determining the mass-transfer coefficient to a sphere, Steele and Geankoplis (S3) used a solid sphere of
benzoic acid held rigidly by a rear support in a pipe. Before the run the sphere was weighed. After flow of
the fluid for a timed interval, the sphere was removed, dried, and weighed again to give the amount of
mass transferred, which was small compared to the weight of the sphere. From the mass transferred and
the area of the sphere, the flux NA was calculated. Then the driving force (cAS − 0) was used to calculate
kL, where cAS is the solubility and the water contained no benzoic acid.

Another method used is to flow gases over various geometries wet with evaporating liquids. For mass
transfer from a flat plate, a porous blotter wet with the liquid serves as the plate.

If the solution is quite dilute, then the mass-transfer coefficient measured is   and the dilute

low flux coefficient   or   is experimentally obtained.


                             
                                                 
                                             
                                               
     

7.3. MASS­TRANSFER COEFFICIENTS FOR VARIOUS GEOMETRIES

7.3A. Dim e nsionle ss Nu m b e r s Use d  to C or r e late  Data

The experimental data for mass-transfer coefficients obtained using various kinds of fluids, different
velocities, and different geometries are correlated using dimensionless numbers similar to those for heat
and momentum transfer. Methods of dimensional analysis are discussed in Sections 3.11, 4.14, and 7.8.

The most important dimensionless number is the Reynolds number NRe, which indicates degree of
turbulence:

Equation 7.3-1

where L is diameter Dp for a sphere, diameter D for a pipe, or length L for a flat plate. The velocity ν is the
mass average velocity if in a pipe. In a packed bed the superficial velocity ν' in the empty cross section is
often used, or sometimes ν = ν'/ε is used, where ν is interstitial velocity and є void fraction of bed.

The Schmidt number is

Equation 7.3-2

The viscosity μ and density ρ used are for the actual flowing mixture of solute A and fluid B. If the
mixture is dilute, properties of the pure fluid B can be used. The Prandtl number cpμ/k for heat transfer is
analogous to the Schmidt number for mass transfer. The Schmidt number is the ratio of the shear
component for diffusivity μ/ρ to the diffusivity for mass transfer DAB; it physically relates the relative
thickness of the hydrodynamic layer and mass-transfer boundary layer.

The Sherwood number, which is dimensionless, is

Equation 7.3-3
Other substitutions from Table 7.2-1 can be made for   in Eq. (7.3-3).

The Stanton number occurs often and is

Equation 7.3-4

Again, substitution for   can be made. GM = νρ/Mav  = νc.

Often the mass-transfer coefficient is correlated as a dimensionless JD factor, which is related to   and
NSh as follows:

Equation 7.3-5

For heat transfer a dimensionless JH factor is as follows:

Equation 7.3-6

7.3B. Analogie s Am ong M ass, He at, and  M om e ntu m  Tr ansfe r

1. Int r od u ct ion

In molecular transport of momentum, heat, or mass there are many similarities, which were pointed out
in Chapters 2–6. The molecular diffusion equations of Newton for momentum, Fourier for heat, and Fick
for mass are very similar, and we can say that we have analogies among these three molecular transport
processes. There are also similarities in turbulent transport, as discussed in Sections 5.7C and 6.1A,
where the flux equations were written using the turbulent eddy momentum diffusivity εt, the turbulent
eddy thermal diffusivity αt, and the turbulent eddy mass diffusivity εM. However, these similarities are
not as well defined mathematically or physically and are more difficult to relate to each other.

A great deal of effort has been devoted in the literature to developing analogies among these three
transport processes for turbulent transfer so as to allow prediction of one from any of the others. We
discuss several next.
2. R ey nold s a na log y

Reynolds was the first to note similarities in transport processes and relate turbulent momentum and
heat transfer. Since then, mass transfer has also been related to momentum and heat transfer. We derive
this analogy from Eqs. (6.1-4)–(6.1-6) for turbulent transport. For fluid flow in a pipe, for heat transfer
from the fluid to the wall, Eq. (6.1-5) becomes as follows, where z is distance from the wall:

Equation 7.3-7

For momentum transfer, Eq. (6.1-4) becomes

Equation 7.3-8

Next we assume that α and μ/ρ are negligible and that αt = εt. Then dividing Eq. (7.3-7) by (7.3-8),

Equation 7.3-9

If we assume that heat flux q/A in a turbulent system is analogous to momentum flux τ, the ratio τ/(q/A)
must be constant for all radial positions. We now integrate between conditions at the wall where T = Ti
and ν = 0 to some point in the fluid where T is the same as the bulk T, and assume that the velocity at
this point is the same as νav , the bulk velocity. Also, q/A is understood to be the flux at the wall, as is the
shear at the wall, written as τs. Hence,

Equation 7.3-10

Also, substituting q/A = h(T − Ti) and   from Eq. (2.10-4) into Eq. (7.3-10),

Equation 7.3-11
In a similar manner, using Eq. (6.1-6) for   and  , we can relate this to Eq.
(7.3-8) for momentum transfer. Then, the complete Reynolds analogy is

Equation 7.3-12

Experimental data for gas streams agree approximately with Eq. (7.3-12) if the Schmidt and Prandtl
numbers are near 1.0 and only skin friction is present in flow past a flat plate or inside a pipe. When
liquids are present and/or form drag is present, the analogy is not valid.

3. Ot her  a na log ies

The Reynolds analogy assumes that the turbulent diffusivities εt, αt, and εM are all equal and that the
molecular diffusivities μ/ρ, α, and DAB are negligible compared to the turbulent diffusivities. When the
Prandtl number (μ/ρ)/α is 1.0, then μ/ρ = α; also, for NSc = 1.0, μ/ρ = DAB. Then, (μ/ρ + εt) = (α + αt) =
(DAB + εM) and the Reynolds analogy can be obtained with the molecular terms present. However, the
analogy breaks down when the viscous sublayer becomes important, since the eddy diffusivities diminish
to zero and the molecular diffusivities become important.

Prandtl modified the Reynolds analogy by writing the regular molecular diffusion equation for the
viscous sublayer and a Reynolds analogy equation for the turbulent core region. Then, since these
processes are in series, these equations were combined to produce an overall equation (G1). The results
again are poor for fluids where the Prandtl and Schmidt numbers differ from 1.0.

Von Kármán further modified the Prandtl analogy by considering the buffer region in addition to the
viscous sublayer and the turbulent core. These three regions are shown in the universal velocity profile in
Fig. 3.10-4. Again, an equation is written for molecular diffusion in the viscous sublayer using only the
molecular diffusivity and a Reynolds analogy equation for the turbulent core. Both the molecular and
eddy diffusivity are used in an equation for the buffer layer, where the velocity in this layer is used to
obtain an equation for the eddy diffusivity. These three equations are then combined to give the von
Kármán analogy. Since then, numerous other analogies have appeared (P1, S4).

4 . C hilt on a nd  C olb u r n J-fa ct or  a na log y

The most successful and most widely used analogy is the Chilton and Colburn J-factor analogy (C2).
This analogy is based on experimental data for gases and liquids in both the laminar and turbulent flow
regions and is written as follows:

Equation 7.3-13
Although this is an equation based on experimental data for both laminar and turbulent flow, it can be
shown to satisfy the exact solution derived from laminar flow over a flat plate in Sections 3.10 and 5.7.

Equation (7.3-13) has been shown to be quite useful in correlating momentum, heat, and mass-transfer
data. It permits the prediction of an unknown transfer coefficient when one of the other coefficients is
known. In momentum transfer the friction factor is obtained for the total drag or friction loss, which
includes form drag or momentum losses due to blunt objects as well as skin friction. For flow past a flat
plate or in a pipe, where no form drag is present, f/2 = JH = JD. When form drag is present, as in flow in
packed beds or past other blunt objects, f/2 is greater than JH or JD, and JH ≅ JD.

7.3C . De r iv ation of M ass-Tr ansfe r  C oe fficie nts in Lam inar  Flow

1. Int r od u ct ion

When a fluid is flowing in laminar flow and mass transfer by molecular diffusion is occurring, the
equations are very similar to those for heat transfer by conduction in laminar flow. The phenomena of
heat and mass transfer are not always completely analogous, since in mass transfer several components
may be diffusing. Also, the flux of mass perpendicular to the direction of the flow must be small so as not
to distort the laminar velocity profile.

In theory it is not necessary to have experimental mass-transfer coefficients for laminar flow, since the
equations for momentum transfer and diffusion can be solved. However, in many actual cases it is
difficult to describe mathematically the laminar flow for certain geometries, such as flow past a cylinder
or in a packed bed. Hence, experimental mass-transfer coefficients are often obtained and correlated. A
simplified theoretical derivation will be given for two cases of laminar flow.

2. M a ss t r a nsfer  in la mina r  flow  in a  t u b e

We consider the case of mass transfer from a tube wall to a fluid inside in laminar flow, where, for
example, the wall is made of solid benzoic acid which is dissolving in water. This is similar to heat
transfer from a wall to the flowing fluid where natural convection is negligible. For fully developed flow,
the parabolic velocity derived as Eqs. (2.6-18) and (2.6-20) is

Equation 7.3-14

where νx is the velocity in the x direction at the distance r from the center. For steady state diffusion in a
cylinder, a mass balance can be made on a differential element where the rate in by convection plus
diffusion equals the rate out radially by diffusion to give

Equation 7.3-15
Then, ∂2cA/∂x2 = 0 if the diffusion in the x direction is negligible compared to that by convection.
Combining Eqs. (7.3-14) and (7.3-15), the final solution (S1) is a complex series similar to the Graetz
solution for heat transfer and a parabolic velocity profile.

If it is assumed that the velocity profile is flat, as in rodlike flow, the solution is more easily obtained (S1).
A third solution, called the approximate Leveque solution, has been obtained, where there is a linear
velocity profile near the wall and the solute diffuses only a short distance from the wall into the fluid.
This is similar to the parabolic-velocity-profile solution at high flow rates. Experimental design
equations are presented in Section 7.3D for this case.

3. Diffu sion in a  la mina r  fa lling  film

In Section 2.9C we derived the equation for the velocity profile in a falling film shown in Fig. 7.3-1a. We
will consider mass transfer of solute A into a laminar falling film, which is important in wetted-wall
columns, in developing theories to explain mass transfer in stagnant pockets of fluids, and in turbulent
mass transfer. The solute A in the gas is absorbed at the interface and then diffuses a distance into the
liquid so that it has not penetrated the whole distance × = δ at the wall. At steady state the inlet
concentration cA = 0. The concentration profile of cA at a point z distance from the inlet is shown in Fig.
7.3-1a.

Figure 7.3-1. Diffusion of solute A in a laminar falling film: (a) velocity profile and concentration profile, (b)
small element for mass balance.

A mass balance will be made on the element shown in Fig. 7.3-1b. For steady state, rate of input = rate of
output:

Equation 7.3-16
For a dilute solution the diffusion equation for A in the x direction is

Equation 7.3-17

For the z direction the diffusion is negligible:

Equation 7.3-18

Dividing Eq. (7.3-16) by Δx Δz, letting Δx and Δz approach zero, and substituting Eqs. (7.3-17) and (7.3-
18) into the result, we obtain

Equation 7.3-19

From Eqs. (2.9-24) and (2.9-25), the velocity profile is parabolic and is νz = νzmax [1 − (×/δ2)]. Also, 

. If the solute has penetrated only a short distance into the fluid, that is, short
contact times of t = z/νmax, then the A that has diffused has been carried along at the velocity νzmax, or
νmax if the subscript z is dropped. Then Eq. (7.3-19) becomes

Equation 7.3-20

Using the boundary conditions of cA = 0 at z = 0, cA = cA0 at × = 0, and cA = 0 at × = ∞, we can integrate
Eq. (7.3-20) to obtain

Equation 7.3-21
where erf y is the error function and erfc y = 1 − erf y. Values of erf y are standard tabulated functions.

To determine the local molar flux at the surface × = 0 at position z from the top entrance, we write (B1)

Equation 7.3-22

The total moles of A transferred per second to the liquid over the entire length z = 0 to z = L, where the
vertical surface is unit width, is

Equation 7.3-23

The term L/νmax is t L, time of exposure of the liquid to the solute A in the gas. This means the rate of

mass transfer is proportional to   and  . This is the basis for the penetration theory in


turbulent mass transfer where pockets of liquid are exposed to unsteady-state diffusion (penetration) for
short contact times.

7.3D. M ass Tr ansfe r  for  Flow  Insid e  Pip e s

1. M a ss t r a nsfer  for  la mina r  flow  insid e p ip es

When a liquid or gas is flowing inside a pipe and the Reynolds number Dνρ/μ is below 2100, laminar flow
occurs. Experimental data obtained for mass transfer from the walls for gases (G2, L1) are plotted in Fig.
7.3-2 for values of W/DABρL less than about 70. The ordinate is (cA − cA0)/(cAi − cA0), where cA is the exit
concentration, cA0 inlet concentration, and cAi concentration at the interface between the wall and the
gas. The dimensionless abscissa is W/DABρL or NReNSc(D/L)(π/4), where W is flow in kg/s and L is
length of mass-transfer section in m. Since the experimental data follow the rodlike plot, that line should
be used. The velocity profile is assumed fully developed to parabolic form at the entrance.

Figure 7.3-2. Data for diffusion in a fluid in streamline flow inside a pipe: filled circles, vaporization data of
Gilliland and Sherwood; open circles, dissolving-solids data of Linton and Sherwood. [From W. H. Linton and T.
K. Sherwood, Chem. Eng. Progr., 46, 258 (1950). With permission.]

For liquids that have small values of DAB, data follow the parabolic flow line, which is as follows for
W/DABρL over 400:

Equation 7.3-24

2. M a ss t r a nsfer  for  t u r b u lent  flow  insid e p ip es

For turbulent flow when Dνρ/μ > 2100 for gases or liquids flowing inside a pipe,

Equation 7.3-25

The equation holds for NSc of 0.6 to 3000 (G2, L1). Note that the NSc for gases is in the range 0.5–3 and
for liquids is above 100 in general. Equation (7.3-25) for mass transfer and Eq. (4.5-8) for heat transfer
inside a pipe are similar to each other.

3. M a ss t r a nsfer  for  flow  insid e w et t ed -w a ll t ow er s


When a gas is flowing inside the core of a wetted-wall tower, the same correlations that are used for mass
transfer of a gas in laminar or turbulent flow in a pipe are applicable. This means that Eqs. (7.3-24) and
(7.3-25) can be used to predict mass transfer for the gas. For the mass transfer in the liquid film flowing
down the wetted-wall tower, Eqs. (7.3-22) and (7.3-23) can be used for Reynolds numbers of 4Г/μ as
defined by Eq. (2.9-29) up to about 1200, and the theoretically predicted values should be multiplied by
about 1.5 because of ripples and other factors. These equations hold for short contact times or Reynolds
numbers above about 100 (S1).

EXAMPLE 7.3-1. Mass Transfer Inside a Tube
A tube is coated on the inside with naphthalene and has an inside diameter of 20 mm and a
length of 1.10 m. Air at 318 K and an average pressure of 101.3 kPa flows through this pipe at a
velocity of 0.80 m/s. Assuming that the absolute pressure remains essentially constant,
calculate the concentration of naphthalene in the exit air. Use the physical properties given in
Example 6.2-4.

S olu t ion: From Example 6.2-4, DAB = 6.92 × 10−6 m2/s and the vapor pressure pAi = 74.0 Pa

or cAi = pAi/RT = 74.0/(8314.3 × 318) = 2.799 × 10−5 kg mol/m3. For air, from Appendix A.3,

μ = 1.932 × 10−5 Pa · s, ρ = 1.114 kg/m3. The Schmidt number is

The Reynolds number is

Hence, the flow is laminar. Then,

Using Fig. 7.3-2 and the rodlike flow line, (cA − cA0)/(cAi − cA0) = 0.55. Also, cA0(inlet) = 0.

Then, (cA − 0)/(2.799 × 10−5 − 0) = 0.55. Solving cA (exit concentration) = 1.539 × 10−5 kg

mol/m3.

7.3E. M ass Tr ansfe r  for  Flow  Ou tsid e  S olid  S u r face s

1. M a ss t r a nsfer  in flow  p a r a llel t o fla t  p la t es

The mass transfer and vaporization of liquids from a plate or flat surface to a flowing stream is of interest
in the drying of inorganic and biological materials, in the evaporation of solvents from paints, for plates
in wind tunnels, and in flow channels in chemical process equipment.

When the fluid flows past a plate in a free stream in an open space the boundary layer is not fully
developed. For gases or evaporation of liquids in the gas phase and for the laminar region of NRe,L = Lνρ/
μ less than 15 000, the data can be represented within ±25% by the equation (S4)

Equation 7.3-26

Writing Eq. (7.3-26) in terms of the Sherwood number NSh,

Equation 7.3-27

where L is the length of plate in the direction of flow. Also, JD = JH = f/2 for this geometry. For gases and
NRe,L of 15 000–300 000, the data are represented within ±30% by JD = JH = f/2 as

Equation 7.3-28

Experimental data for liquids are correlated within about ±40% by the following for a NRe,L of 600–50
000 (L2):

Equation 7.3-29

EXAMPLE 7.3-2. Mass Transfer from a Flat Plate
A large volume of pure water at 26.1°C is flowing parallel to a flat plate of solid benzoic acid,
where L = 0.244 m in the direction of flow. The water velocity is 0.061 m/s. The solubility of
benzoic acid in water is 0.02948 kg mol/m3. The diffusivity of benzoic acid is 1.245 × 10−9
m2/s. Calculate the mass-transfer coefficient kL and the flux NA.

S olu t ion: Since the solution is quite dilute, the physical properties of water at 26.1°C from
Appendix A.2 can be used:
The Schmidt number is

The Reynolds number is

Using Eq. (7.3-29),

The definition of JD from Eq. (7.3-5) is

Equation 7.3-5

Solving for  . Substituting known values and solving,

In this case, diffusion is for A through nondiffusing B, so kc in Eq. (7.2-10) should be used:

Equation 7.2-10
Since the solution is very dilute, xBM ≅ 1.0 and   Also, cA1 = 2.948 × 10−2 kg mol/m3
(solubility) and cA2 = 0 (large volume of fresh water). Substituting into Eq. (7.2-10),

2. M a ss t r a nsfer  for  flow  p a st  sing le sp her es

For flow past single spheres and for very low NRe = Dρνρ/μ, where ν is the average velocity in the empty

test section before the sphere, the Sherwood number, which is  , should approach a value of
2.0. This can be shown from Eq. (6.2-33), which was derived for a stagnant medium. Rewriting Eq. (6.2-
33) as follows, where Dp is the sphere diameter,

Equation 7.3-30

The mass-transfer coefficient kc, which is   for a dilute solution, is then

Equation 7.3-31

Rearranging,

Equation 7.3-32

Of course, natural convection effects could increase  .

For gases, for a Schmidt number range of 0.6–2.7 and a Reynolds number range of 1–48 000, a modified
equation (G1) can be used:
Equation 7.3-33

This equation also holds for heat transfer, where the Prandtl number replaces the Schmidt number and
the Nusselt number hDp/k replaces the Sherwood number.

For liquids (G3) and a Reynolds number range of 2 to about 2000, the following can be used:

Equation 7.3-34

For liquids and a Reynolds number of 2000–17 000, the following can be used (S5):

Equation 7.3-35

EXAMPLE 7.3-3. Mass Transfer from a Sphere
Calculate the value of the mass-transfer coefficient and the flux for mass transfer from a sphere
of naphthalene to air at 45°C and 1 atm abs flowing at a velocity of 0.305 m/s. The diameter of
the sphere is 25.4 mm. The diffusivity of naphthalene in air at 45°C is 6.92 × 10−6 m2/s and
the vapor pressure of solid naphthalene is 0.555 mm Hg. Use English and SI units.

S olu t ion: In English units DAB = 6.92 × 10−6(3.875 × 104) = 0.2682 ft 2/h. The diameter Dp =


0.0254 m = 0.0254(3.2808) = 0.0833 ft. From Appendix A.3 the physical properties of air will
be used, since the concentration of naphthalene is low:

The Schmidt number is
The Reynolds number is

Equation (7.3-33) for gases will be used:

From Eq. (7.3-3),

Substituting the knowns and solving,

From Table 7.2-1,

Hence, for T = 45 + 273 = 318 K = 318(1.8) = 574°R,
Since the gas is very dilute, y BM ≅ 1.0 and  . Substituting into Eq. (7.2-12) for A

diffusing through stagnant B and noting that pA1 = 0.555/760 = 7.303 × 10−4 atm = 74.0 Pa
and pA2 = 0 (pure air),

The area of the sphere is

Total amount evaporated = NA A = (1.18 × 10−4)(2.18 × 10−2) = 2.572 × 10−6 lb mol/h =

(1.599 × 10−7 )(2.025 × 10−3) = 3.238 × 10−10 kg mol/s

3. M a ss t r a nsfer  t o p a ck ed  b ed s

Mass transfer to and from packed beds occurs often in processing operations, including drying
operations, adsorption or desorption of gases or liquids by solid particles such as charcoal, and mass
transfer of gases and liquids to catalyst particles. By using a packed bed a large amount of mass-transfer
area can be contained in a relatively small volume.

The void fraction in a bed is ε m3 volume void space divided by the m3 total volume of void space plus
solid. The values range from 0.3 to 0.5 in general. Because of flow channeling, nonuniform packing, and
so forth, accurate experimental data are difficult to obtain and data from different investigators can
deviate considerably.

For a Reynolds number range of 10–10 000 for gases in a packed bed of spheres (D4), the recommended
correlation with an average deviation of about ±20% and a maximum of about ±50% is

Equation 7.3-36

It has been shown (G4, G5) that JD and JH are approximately equal. The Reynolds number is defined as
NRe = Dpν'ρ/μ, where Dp is diameter of the spheres and ν' is the superficial mass average velocity in the
empty tube without packing. For Eqs. (7.3-36)–(7.3-39) and Eqs. (7.3-5)–(7.3-6), ν' is used.
For mass transfer of liquids in packed beds, the correlations of Wilson and Geankoplis (W1) should be
used. For a Reynolds number Dpν'ρ/μ range of 0.0016–55 and a Schmidt number range of 165–70 000,
the equation to use is

Equation 7.3-37

For liquids and a Reynolds number range of 55–1500 and a Schmidt number range of 165–10 690,

Equation 7.3-38

Or, as an alternate, Eq. (7.3-36) can be used for liquids for a Reynolds number range of 10–1500.

For fluidized beds of spheres, Eq. (7.3-36) can be used for gases and liquids and a Reynolds number range
of 10–4000. For liquids in a fluidized bed and a Reynolds number range of 1–10 (D4),

Equation 7.3-39

If packed beds of solids other than spheres are used, approximate correction factors can be used with Eqs.
(7.3-36)–(7.3-38) for spheres. This is done, for example, for a given nonspherical particle as follows. The
particle diameter to use in the equations for predicting JD is the diameter of a sphere with the same
surface area as the given solid particle. The flux to these particles in the bed is then calculated using the
area of the given particles. An alternative approximate procedure is given elsewhere (G6).

4 . C a lcu la t ion met hod  for  p a ck ed  b ed s

To calculate the total flux in a packed bed, JD is first obtained and then kc in m/s from the JD. Then,

knowing the total volume Vb m3 of the bed (void plus solids), the total external surface area A m2 of the
solids for mass transfer is calculated using Eqs. (7.3-40) and (7.3-41):

Equation 7.3-40

where a is the m2 surface area/m3 total volume of bed when the solids are spheres, and

Equation 7.3-41
To calculate the mass-transfer rate, the log mean driving force at the inlet and outlet of the bed should be
used:

Equation 7.3-42

where the final term is the log mean driving force: cAi is the concentration at the surface of the solid, in kg

mol/m3; cA1 is the inlet bulk fluid concentration; and cA2 is the outlet. The material-balance equation on
the bulk stream is

Equation 7.3-43

where V is volumetric flow rate of fluid entering in m3/s. Equations (7.3-42) and (7.3-43) must both be
satisfied. The use of these two equations is similar to the use of the log mean temperature difference and
heat balance in heat exchangers. These two equations can also be used for a fluid flowing in a pipe or past
a flat plate, where A is the pipe wall area or plate area.

EXAMPLE 7.3-4. Mass Transfer of a Liquid in a Packed
Bed
Pure water at 26.1°C flows at the rate of 5.514 × 10−7  m3/s through a packed bed of benzoic-
acid spheres having a diameter of 6.375 mm. The total surface area of the spheres in the bed is
0.01198 m2 and the void fraction is 0.436. The tower diameter is 0.0667 m. The solubility of
benzoic acid in water is 2.948 × 10−2 kg mol/m3.

a.  Predict the mass-transfer coefficient kc. Compare with the experimental value of 4.665

× 10−6 m/s by Wilson and Geankoplis (W1).

b.  Using the experimental value of kc, predict the outlet concentration of benzoic acid in
the water.

S olu t ion: Since the solution is dilute, the physical properties of water will be used at 26.1°C
from Appendix A.2. At 26.1°C, μ = 0.8718 × 10−3 Pa · s, ρ = 996.7 kg/m3. At 25.0°C, μ =
0.8940 × 10−3 Pa · s, and from Table 6.3-1, DAB = 1.21 × 10−9 m2/s. To correct DAB to 26.1°C

using Eq. (6.3-9),  . Hence,
The tower cross-sectional area = (π/4)(0.0667)2 = 3.494 × 10−3 m2. Then ν' = (5.514 ×
10−7 )/(3.494 × 10−3) = 1.578 × 10−4 m/s. Then,

The Reynolds number is

Using Eq. (7.3-37) and assuming kc =   for dilute solutions,

Then, using Eq. (7.3-5) and solving,

The predicted   = 4.447 × 10−6 m/s. This compares with the experimental value of 4.665 ×
10−6 m/s.

For part (b), using Eqs. (7.3-42) and (7.3-43),

Equation 7.3-44
The values to substitute into Eq. (7.3-44) are cAi = 2.948 × 10−2, cA1 = 0, A = 0.01198, V =

5.514 × 10−7 .

Solving, cA2 = 2.842 × 10−3 kg mol/m3.

5. M a ss t r a nsfer  for  flow  p a st  sing le cy lind er s

Experimental data have been obtained for mass transfer from single cylinders when the flow is
perpendicular to the cylinder. The cylinders are long and mass transfer to the ends of the cylinder is not
considered. For the Schmidt number range of 0.6 to 2.6 for gases and 1000 to 3000 for liquids and a
Reynolds number range of 50 to 50 000, data from many references (B3, L1, M1, S4, V1) have been
plotted, and the correlation to use is as follows:

Equation 7.3-45

The data scatter considerably by up to ±30%. This correlation can also be used for heat transfer, with JD
= JH.

6 . Liq u id  met a ls ma ss t r a nsfer

In recent years several correlations for mass-transfer coefficients of liquid metals have appeared in the
literature. It has been found (G1) that with moderate safety factors, the correlations for nonliquid metals
mass transfer may be used for liquid metals mass transfer. Care must be taken to ensure that the solid
surface is wetted. Also, if the solid is an alloy, there may exist a resistance to diffusion in the solid phase.
                             
                                                 
                                             
                                               
     

7.4. MASS TRANSFER TO SUSPENSIONS OF SMALL PARTICLES

7.4 A. Intr od u ction

Mass transfer from or to small suspended particles in an agitated solution occurs in a number of process
applications. In liquid-phase hydrogenation, hydrogen diffuses from gas bubbles, through an organic
liquid, and then to small suspended catalyst particles. In fermentation, oxygen diffuses from small gas
bubbles, through the aqueous medium, and then to small suspended microorganisms.

For a liquid–solid dispersion, increased agitation over and above that necessary to freely suspend very
small particles has very little effect on the mass-transfer coefficient kL to the particle (B2). When the
particles in a mixing vessel are just completely suspended, turbulence forces balance those due to
gravity, and the mass-transfer rates are the same as for particles freely moving under gravity. With very
small particles of, say, a few μm or so, which is the size of many microorganisms in fermentations and
some catalyst particles, their size is smaller than eddies, which are about 100 μm or so in size. Hence,
increased agitation will have little effect on mass transfer except at very high agitation.

For a gas–liquid–solid dispersion, such as in fermentation, the same principles hold. However,
increased agitation increases the number of gas bubbles and hence the interfacial area. The mass-transfer
coefficients from the gas bubble to the liquid and from the liquid to the solid are relatively unaffected.

7.4 B. Eq u ations for  M ass Tr ansfe r  to S m all Par ticle s

1. M a ss t r a nsfer  t o sma ll p a r t icles <0.6  mm

Equations for predicting mass transfer to small particles in suspension have been developed which cover
three size ranges of particles. The equation for particles <0.6 mm (600 μm) is discussed first.

The following equation has been shown to hold for predicting mass-transfer coefficients from small gas
bubbles such as oxygen or air to the liquid phase or from the liquid phase to the surface of small catalyst
particles, microorganisms, other solids, or liquid drops (B2, C3):

Equation 7.4-1

where DAB is the diffusivity of the solute A in solution in m2/s, Dp is the diameter of the gas bubble or the

solid particle in m, μc is the viscosity of the solution in kg/m · s, g = 9.80665 m/s2, Δρ = (ρc − ρp) or (ρp

− ρc), ρc is the density of the continuous phase in kg/m3, and ρp is the density of the gas or solid particle.
The value of Δρ is always positive.

The first term on the right in Eq. (7.4-1) is the molecular diffusion term, and the second term is that due
to free fall or rise of the sphere due to gravitational forces. This equation has been experimentally checked
for dispersions of low-density solids in agitated dispersions and for small gas bubbles in agitated
systems.

EXAMPLE 7.4-1. Mass Transfer from Air Bubbles in
Fermentation
Calculate the maximum rate of absorption of O2 in a fermenter from air bubbles at 1 atm abs
pressure having diameters of 100 μm at 37°C into water having a zero concentration of
dissolved O2. The solubility of O2 from air in water at 37°C is 2.26 × 10−7  g mol O2/cm3 liquid

or 2.26 × 10−4 kg mol O2/m3. The diffusivity of O2 in water at 37°C is 3.25 × 10−9 m2/s.
Agitation is used to produce the air bubbles.

S olu t ion: The mass-transfer resistance inside the gas bubble to the outside interface of the

bubble can be neglected since it is negligible (B2). Hence, the mass-transfer coefficient 
outside the bubble is needed. The given data are

At 37°C,

Substituting into Eq. (7.4-1),

The flux is as follows, assuming   for dilute solutions:
Knowing the total number of bubbles and their area, the maximum possible rate of transfer of
O2 to the fermentation liquid can be calculated.

In Example 7.4-1, kL was small. For mass transfer of O2 in a solution to a microorganism with Dp ≅ 1
μm, the term 2DAB/Dp would be 100 times larger. Note that at large diameters the second term in Eq.
(7.4-1) becomes small and the mass-transfer coefficient kL becomes essentially independent of size Dp. In
agitated vessels with gas introduced below the agitator in aqueous solutions, or when liquids are aerated
with sintered plates, the gas bubbles are often in the size range covered by Eq. (7.4-1) (B2, C3, T1).

In aerated mixing vessels, the mass-transfer coefficients are essentially independent of the power input.
However, as the power is increased, the bubble size decreases and the mass transfer coefficient continues
to follow Eq. (7.4-1). The dispersions include those in which the solid particles are just completely
suspended in mixing vessels. Increase in agitation intensity above the level needed for complete
suspension of these small particles results in only a small increase in kL (C3).

Equation (7.4-1) has also been shown to apply to heat transfer and can be written as follows (B2, C3):

Equation 7.4-2

2. M a ss t r a nsfer  t o la r g e g a s b u b b les >2.5 mm

For large gas bubbles or liquid drops >2.5 mm, the mass-transfer coefficient can be predicted by

Equation 7.4-3

Large gas bubbles are produced when pure liquids are aerated in mixing vessels and sieve-plate columns

(C1). In this case the mass-transfer coefficient   or kL is independent of the bubble size and is constant
for a given set of physical properties. For the same physical properties the large-bubble Eq. (7.4-3) gives
values of kL about three to four times larger than Eq. (7.4-1) for small particles. Again, Eq. (7.4-3) shows
that the kL is essentially independent of agitation intensity in an agitated vessel and gas velocity in a
sieve-tray tower.
3. M a ss t r a nsfer  t o p a r t icles in t r a nsit ion r eg ion

In mass transfer in the transition region between small and large bubbles in the size range 0.6–2.5 mm,
the mass-transfer coefficient can be approximated by assuming that it increases linearly with bubble
diameter (B2, C3).

4 . M a ss t r a nsfer  t o p a r t icles in hig hly  t u r b u lent  mixer s

In the preceding three regions, the density difference between phases is sufficiently large to cause the
force of gravity to primarily determine the mass-transfer coefficient. This also includes solids just
completely suspended in mixing vessels. When agitation power is increased beyond that needed for
suspension of solid or liquid particles and the turbulence forces become larger than the gravitational
forces, Eq. (7.4-1) is not followed, and Eq. (7.4-4) should be used where small increases in are observed
(B2, C3):

Equation 7.4-4

where P/V is power input per unit volume as defined in Section 3.4. The data deviate substantially by up
to 60% from this correlation. In the case of gas–liquid dispersions it is quite impractical for agitation
systems to exceed gravitational forces.

The experimental data are complicated by the fact that very small particles are easily suspended, and if
their size is on the order of the smallest eddies, the mass-transfer coefficient will remain constant until a
large increase in power input is added above that required for suspension.
                             
                                                 
                                             
                                               
     

7.5. MOLECULAR DIFFUSION PLUS CONVECTION AND CHEMICAL
REACTION

7.5A. Diffe r e nt Typ e s of Flu xe s and  Fick's Law

In Section 6.2B the flux   was defined as the molar flux of A in kg mol A/s · m2 relative to the molar
average velocity νM of the whole or bulk stream. Also, NA was defined as the molar flux of A relative to
stationary coordinates. Fluxes and velocities can also be defined in other ways. Table 7.5-1 lists the
different types of fluxes and velocities often used in binary systems.

Table 7.5-1. Diffe rent Types of Fluxes and Velocities in Binary Systems

    Mass Flux  (kg A/s · m 2 ) Molar Flux (kg mol A/s ·


m 2)

Relative to fixed coordinates nA = ρAνA NA = cAνA

Relative to molar average velocity νM

Relative to mass average velocity ν jA =ρA(νA − ν) JA = cA(νA − ν)

Relations Between Fluxes Above
  NA + NB = cνM NA = nA/MA NA = JA + cAν

  JA = jA/MA nA + nB = ρν

  jA + jB = 0 nA = jA + ρAν

Different Forms of Fick's Law for Diffusion Flux

The velocity ν is the mass average velocity of the stream relative to stationary coordinates and can be
obtained by actually weighing the flow for a timed increment. It is related to the velocity νA and νB by

Equation 7.5-1

where w A is ρA/ρ, the weight fraction of A; w B is the weight fraction of B; and νA is the velocity of A


relative to stationary coordinates in m/s. The molar average velocity νM in m/s is relative to stationary
coordinates:

Equation 7.5-2

The molar diffusion flux relative to the molar average velocity νM defined previously is

Equation 7.5-3

The molar diffusion flux JA relative to the mass average velocity ν is

Equation 7.5-4

Fick's law from Table 7.5-1 as given previously is relative to νM:

Equation 7.5-5

Fick's law can also be defined in terms of a mass flux relative to ν as given in Table 7.5-1:

Equation 7.5-6

EXAMPLE 7.5-1. Proof of Mass Flux Equation
Table 7.5-1 gives the following relation:

Equation 7.5-7

Prove this relationship using the definitions of the fluxes in terms of velocities.

S olu t ion: From Table 7.5-1, substituting ρA(νA − ν) for jA and ρB(νB − ν) for jB, and
rearranging,

Equation 7.5-8

Equation 7.5-9

Substituting Eq. (7.5-1) for ν and ρ for ρA + ρB, the identity is proved.

7.5B. Eq u ation of C ontinu ity for  a Binar y M ixtu r e

A general equation can be derived for a binary mixture of A and B for diffusion and convection that also
includes the terms for unsteady-state diffusion and chemical reaction. We shall make a mass balance on
component A on an element Δx Δy Δz fixed in space as shown in Fig. 7.5-1. The general mass balance on
A is

Equation 7.5-10

Figure 7.5-1. Mass balance for A in a binary mixture.

The rate of mass A entering in the direction relative to stationary coordinates is (nAx|x)Δy Δz kg A/s and
leaving is (nAx|x+Δx)Δy Δz. Similar terms can be written for the y and z directions. The rate of chemical

production of A is r A kg A generated/s · m3 volume and the total rate generated is r A(Δx Δy Δz) kg A/s.


The rate of accumulation of A is (∂ρA/∂t)Δx Δy Δz. Substituting into Eq. (7.5-10) and letting Δx, Δy, and
Δz approach zero,

Equation 7.5-11

In vector notation,

Equation 7.5-12

Dividing both sides of Eq. (7.5-11) by MA,

Equation 7.5-13

where RA is kg mol A generated/s · m3. Substituting NA and Fick's law from Table 7.5-1,

Equation 7.5-14

and writing the equation for all three directions, Eq. (7.5-13) becomes

Equation 7.5-15

This is the final general equation.

7.5C . S p e cial C ase s of the  Eq u ation of C ontinu ity


1. Eq u a t ion for  const a nt  c a nd  D AB

In diffusion with gases the total pressure P is often constant. Then, since c = P/RT, c is constant for
constant temperature T. Starting with the general equation (7.5-15) and substituting ∇xA = ∇cA/c, we
obtain

Equation 7.5-16

2. Eq u imola r  cou nt er d iffu sion for  g a ses

For the special case of equimolar counterdiffusion of gases at constant pressure and no reaction, c =
constant, νM = 0, DAB = constant, RA = 0, and Eq. (7.5-15) becomes

Equation 7.1-9

This equation is Eq. (7.1-9), derived previously, which is also used for unsteady-state diffusion of a dilute
solute A in a solid or a liquid when DAB is constant.

3. Eq u a t ion for  const a nt  ρ  a nd  D AB  (liq u id s)

In dilute liquid solutions, the mass density ρ and DAB can often be considered constant. Starting with
Eq. (7.5-12) we substitute n A = −ρDAB∇w A + ρAν from Table 7.5-1 into this equation. Then using the fact
that for constant ρ, ∇w A = ∇ρA/ρ and also that (▽ · ν) = 0, substituting these into the resulting
equation, and dividing both sides by MA, we obtain

Equation 7.5-17

7.5D. S p e cial C ase s of the  G e ne r al Diffu sion Eq u ation at S te ad y S tate

1. Int r od u ct ion a nd  p hy sica l cond it ions a t  t he b ou nd a r ies

The general equation for diffusion and convection of a binary mixture in one direction with no chemical
reaction has been given previously:

Equation 6.2-14
To integrate this equation at steady state, it is necessary to specify the boundary conditions at z1 and z2.
In many mass-transfer problems the molar ratio NA/NB is determined by the physical conditions
occurring at the two boundaries.

As an example, one boundary of the diffusion path may be impermeable to species B because B is
insoluble in the phase at this boundary. Diffusion of ammonia (A) and nitrogen (B) through a gas phase
to a water phase at the boundary is such a case, since nitrogen is essentially insoluble in water. Hence,
NB = 0, since at steady state NB must have the same value at all points in the path of z2 − z1. In some
cases, a heat balance in the adjacent phase at the boundary can determine the flux ratios. For example, if
component A condenses at a boundary and releases its latent heat to component B, which vaporizes and
diffuses back, the ratios of the latent heats determine the flux ratio.

In another example, the boundary concentration can be fixed by having a large volume of a phase flowing
rapidly by with a given concentration xA1. In some cases the concentration xA1 may be set by an
equilibrium condition, whereby xA1 is in equilibrium with some fixed composition at the boundary.
Chemical reactions can also influence the rates of diffusion and the boundary conditions.

2. Eq u imola r  cou nt er d iffu sion

For the special case of equimolar counterdiffusion, where NA = −NB, Eq. (6.2-14) becomes, as shown
previously, for steady state and constant c,

Equation 7.5-18

3. Diffu sion of A t hr ou g h st a g na nt , nond iffu sing  B

For gas A diffusing through stagnant nondiffusing gas B, NB = 0, and integration of Eq. (6.2-14) gives
Eq. (6.2-22):

Equation 6.2-22

Several other more complicated cases of integration of Eq. (6.2-14) are considered next.

4 . Diffu sion a nd  chemica l r ea ct ion a t  a  b ou nd a r y

Often in catalytic reactions, where A and B are diffusing to and from a catalyst surface, the relation
between the fluxes NA and NB at steady state is controlled by the stoichiometry of a reaction at a
boundary. An example is gas A diffusing from the bulk gas phase to the catalyst surface, where it reacts
instantaneously and irreversibly in a heterogeneous reaction as follows:

Equation 7.5-19

Gas B then diffuses back, as shown in Fig. 7.5-2.

Figure 7.5-2. Diffusion of A and heterogeneous reaction at a surface.

At steady state 1 mol of A diffuses to the catalyst for every 2 mol of B diffusing away, or NB = −2NA. The
negative sign indicates that the fluxes are in opposite directions. Rewriting Eq. (6.2-14) in terms of mole
fractions,

Equation 7.5-20

Next, substituting NB = −2NA into Eq. (7.5-20),

Equation 7.5-21

Rearranging and integrating with constant c (P = constant), we obtain the following:

1. Inst a nt a neou s su r fa ce r ea ct ion

Equation 7.5-22
Equation 7.5-23

Since the reaction is instantaneous, xA2 = 0, because no A can exist next to the catalyst surface. Equation
(7.5-23) describes the overall rate of the process of diffusion plus instantaneous chemical reaction.

2. S low  su r fa ce r ea ct ion

If the heterogeneous reaction at the surface is not instantaneous but slow for the reaction A → 2B, and
the reaction is first order,

Equation 7.5-24

where   is the first-order heterogeneous reaction velocity constant in m/s. Equation (7.5-23) still holds
for this case, but the boundary condition xA2 at z = δ is obtained by solving for xA in Eq. (7.5-24),

Equation 7.5-25

For steady state, NAz=δ = NA. Substituting Eq. (7.5-25) into (7.5-23),

Equation 7.5-26

The rate in Eq. (7.5-26) is less than in Eq. (7.5-23), since the denominator in the latter equation is 1 + xA2

= 1 + 0 and in the former is  .
EXAMPLE 7.5-2. Diffusion and Chemical Reaction at a
Boundary
Pure gas A diffuses from point 1 at a partial pressure of 101.32 kPa to point 2 a distance 2.00
mm away. At point 2 it undergoes a chemical reaction at the catalyst surface and A → 2B.
Component B diffuses back at steady state. The total pressure is P = 101.32 kPa. The
temperature is 300 K and DAB = 0.15 × 10−4 m2/s.

a.  For instantaneous rate of reaction, calculate xA2 and NA.

b.  For a slow reaction where   m/s, calculate xA2 and NA.

S olu t ion: For part (a), pA2 = xA2 = 0 since no A can exist next to the catalyst surface. Since NB

= −2NA, Eq. (7.5-23) will be used as follows: δ = 2.00 × 10−3m, T = 300 K, c = P/RT = 101.32 ×

103/(8314 × 300) = 4.062 × 10−2 kg mol/m3, xA1 = pA1/P = 101.32 × 103/101.32 × 103 = 1.00.

For part (b), from Eq. (7.5-25),  .
Substituting into Eq. (7.5-26),

Solving by trial and error, NA = 1.004 × 10−4 kg mol A/s · m2. Then xA2 = (1.004 × 10−4)/(5.63

× 10−3 × 4.062 × 10−2) = 0.4390.

Even though in part (a) of Example 7.5-2 the rate of reaction is instantaneous, the flux NA is diffusion-
controlled. As the reaction rate slows, the flux NA is decreased also.

5. Diffu sion a nd  homog eneou s r ea ct ion in a  p ha se

Equation (7.5-23) was derived for the case of chemical reaction of A at the boundary on a catalyst surface.
In some cases component A undergoes an irreversible chemical reaction in the homogeneous phase B
while diffusing, as follows: A → C. Assume that component A is very dilute in phase B, which can be a
gas or a liquid. Then at steady state the equation for diffusion of A is as follows, where the bulk-flow term
is dropped:

Equation 7.5-27
Writing a material balance on A shown in Fig. 7.5-3 for the Δz element for steady state,

Equation 7.5-28

Figure 7.5-3. Homogeneous chemical reaction and diffusion in a fluid.

The first-order reaction rate of A per m3 volume is

Equation 7.5-29

where k' is the reaction velocity constant in s−1. Substituting into Eq. (7.5-28) for a cross-sectional area of
1 m2 with the rate of accumulation being 0 at steady state,

Equation 7.5-30

Next we divide through by Δz and let Δz approach zero:

Equation 7.5-31
Substituting Eq. (7.5-27) into (7.5-31),

Equation 7.5-32

The boundary conditions are cA = cA1 for z = 0 and cA = cA2 for z = L. Solving,

Equation 7.5-33

This equation can be used at steady state to calculate cA at any z and can be used for reactions in gases,
liquids, or even solids, where the solute A is dilute.

As an alternative derivation of Eq. (7.5-32), we can use Eq. (7.5-17) for constant ρ and DAB:

Equation 7.5-17

We set the first term ∂cA/∂t = 0 for steady state. Since we are assuming dilute solutions and neglecting
the bulk flow term, ν = 0, making the second term in Eq. (7.5-17) zero. For a first-order reaction of A

where A disappears,   kg mol A generated/s · m3. Writing the diffusion term   for


the z direction only, we obtain

Equation 7.5-34

which is, of course, identical to Eq. (7.5-32).

7.5E. Unste ad y-S tate  Diffu sion and  R e action in a S e m i-infinite  M e d iu m


Here we consider a case where dilute A is absorbed at the surface of a solid or stagnant fluid phase and
then unsteady-state diffusion and reaction occur in the phase. The fluid or solid phase B is considered
semi-infinite. At the surface, where z = 0, the concentration of cA is kept constant at cA0. The dilute
solute A reacts by a first-order mechanism

Equation 7.5-35

and the rate of generation is  . The same diagram as in Fig. 7.5-3 holds. Using Eq. (7.5-30) but
substituting (∂cA/∂t)(Δz)(1) for the rate of accumulation,

Equation 7.5-36

This becomes

Equation 7.5-37

The initial and boundary conditions are

Equation 7.5-38

The solution by Danckwerts (D1) is

Equation 7.5-39
The total amount Q of A absorbed up to time t is

Equation 7.5-40

where Q is kg mol A absorbed/m2. Many actual cases are approximated by this case. The equation is
useful where absorption occurs at the surface of a stagnant fluid or a solid and unsteady-state diffusion
and reaction occur in the solid or fluid. The results can be used to measure the diffusivity of a gas in a
solution, to determine reaction rate constants k' of dissolved gases, and to determine solubilities of gases
in liquids with which they react. Details are given elsewhere (D3).

EXAMPLE 7.5-3. Reaction and Unsteady-State Diffusion
Pure CO2 gas at 101.32 kPa pressure is absorbed into a dilute alkaline buffer solution
containing a catalyst. The dilute, absorbed solute CO2 undergoes a first-order reaction, with k'

= 35 s−1 and DAB = 1.5 × 10−9 m2/s. The solubility of CO2 is 2.961 × 10−7  kg mol/m3 · Pa (D3).

The surface is exposed to the gas for 0.010 s. Calculate the kg mol CO2 absorbed/m2 surface.

S olu t ion: For use in Eq. (7.5-40), k't = 35(0.01) = 0.350. Also, cA0 = 2.961 × 10−7  (kg mol/m3

· Pa)(101.32 × 103 Pa) = 3.00 × 10−2 kg mol SO2/m3.

7.5F. M u lticom p one nt Diffu sion of G ase s

The equations derived in this chapter have been for a binary system of A and B, which is probably the
most important and most useful one. However, multicomponent diffusion sometimes occurs where three
or more components A, B, C, . . . are present. The simplest case is for diffusion of A in a gas through a
stagnant, nondiffusing mixture of B, C, D, . . . at constant total pressure. Hence, NB = 0, Nc = 0, . . . . The
final equation derived using the Stefan–Maxwell method (G1) for steady-state diffusion is

Equation 7.5-41

where piM is the log mean of pi1 = P − pA1 and pi2 = P − pA2. Also,

Equation 7.5-42
where   = mol B/mol inerts = xB/(1−xA),  .

EXAMPLE 7.5-4. Diffusion of A Through Nondiffusing B
and C
At 298 K and 1 atm total pressure, methane (A) is diffusing at steady state through
nondiffusing argon (B) and helium (C). At z1 = 0, the partial pressures in atm are pA1 = 0.4,
pB1 = 0.4, and pC1 = 0.2, and at z2 = 0.005 m, pA2 = 0.1, pB2 = 0.6, and pC2 = 0.3. The binary

diffusivities from Table 6.2-1 are DAB = 2.02 × 10−5 m2/s, DAC = 6.75 × 10−5 m2/s, and DBC =

7.29 × 10−5 m2/s. Calculate NA.

S olu t ion: At point 1,   = xB/(1 − xA) = 0.4/(1 − 0.4) = 0.667. At point 2,   = 0.6/(1 − 0.1)

= 0.667. The value of   is constant throughout the path. Also, 

Substituting into Eq. (7.5-42),

For calculating piM, pi1 = P − pA1 = 1.0 − 0.4 = 0.6 atm, pi2 = P − pA2 = 1.0 − 0.1 = 0.90. Then,

Substituting into Eq. (7.5-41),
Using atm pressure units,

A number of analytical solutions have been obtained for other cases, such as for equimolar
diffusion of three components, diffusion of components A and B through stagnant C, and the
general case of two or more components diffusing in a multicomponent mixture. These are
discussed in detail with examples by Geankoplis (G1); the reader is referred there for further
details.
                             
                                                 
                                             
                                               
     

7.6. DIFFUSION OF GASES IN POROUS SOLIDS AND CAPILLARIES

7.6 A. Intr od u ction

In Section 6.5C diffusion in porous solids that depends on structure was discussed for liquids and gases.
For gases it was assumed that the pores were very large and Fickian-type diffusion occurred. However,
the pores are often small in diameter and the mechanism of diffusion is basically changed.

Diffusion of gases in small pores frequently occurs in heterogeneous catalysis where gases diffuse through
very small pores to react on the surface of the catalyst. In freeze-drying of foods such as turkey meat,
gaseous H2O diffuses through very fine pores of the porous structure.

Since the pores or capillaries of porous solids are often small, the diffusion of gases may depend upon the
diameter of the pores. We first define a mean free path λ, which is the average distance a gas molecule
travels before it collides with another gas molecule:

Equation 7.6-1

where λ is in m, μ is viscosity in Pa · s, P is pressure in N/m2, T is temperature in K, M = molecular
weight in kg/kg mol, and R = 8.3143 × 103 N · m/kg mol · K. Note that low pressures give large values of
λ. For liquids, since λ is so small, diffusion follows Fick's law.

In the next sections we shall consider what happens to the basic mechanisms of diffusion in gases as the
relative value of the mean free path compared to the pore diameter varies. The total pressure P in the
system will be constant, but partial pressures of A and B may be different.

7.6 B. K nu d se n Diffu sion of G ase s

In Fig. 7.6-1a a gas molecule A at partial pressure pA1 at the entrance to a capillary is diffusing through
the capillary having a diameter d m. The total pressure P is constant throughout. The mean free path λ is
large compared to the diameter d. As a result, the molecule collides with the wall and molecule–wall
collisions are important. This type of diffusion is called Knudsen diffusion.

Figure 7.6-1. Types of diffu sion of gases in small capillary tubes: (a) Knudsen gas diffu sion, (b) molecular or


Fick's gas diffu sion, (c) tr ansition gas diffu sion.
The Knudsen diffusivity is independent of pressure P and is calculated from

Equation 7.6-2

where DKA is diffusivity in m2/s,   is average pore radius in m, and   is the average molecular velocity

for component A in m/s. Using the kinetic theory of gases to evaluate   the final equation for DKA is

Equation 7.6-3

where MA is molecular weight of A in kg/kg mol and T is temperature in K.

EXAMPLE 7.6-1. Knudsen Diffusivity of Hydrogen
A H2(A)—C 2H6(B) gas mixture is diffusing in a pore of a nickel catalyst used for

hydrogenation at 1.01325 × 105 Pa pressure and 373 K. The pore radius is 60 Å (angstrom).
Calculate the Knudsen diffusivity DKA of H2.

S olu t ion: Substituting into Eq. (7.6-3) for  , MA = 2.016, and T = 373 K,

The flux equation for Knudsen diffusion in a pore is

Equation 7.6-4
Integrating between z1 = 0, pA = pA1 and z2 = L, pA = pA2,

Equation 7.6-5

The diffusion of A for Knudsen diffusion is completely independent of B, since A collides with the walls of
the pore and not with B. A similar equation can be written for component B.

When the Knudsen number NKn  defined as

Equation 7.6-6

is ≥10/1, the diffusion is primarily Knudsen, and Eq. (7.6-5) predicts the flux to within about a 10%
error. As NKn  gets larger, this error decreases, since the diffusion approaches the Knudsen type.

7.6 C . M ole cu lar  Diffu sion of G ase s

As shown in Fig. 7.6-1b, when the mean free path λ is small compared to the pore diameter d or where
NKn  ≤ 1/100, molecule–molecule collisions predominate and molecule–wall collisions are few. Ordinary
molecular or Fickian diffusion holds and Fick's law predicts the diffusion to within about 10%. The error
diminishes as NKn  gets smaller since the diffusion approaches more closely the Fickian type.

The equation for molecular diffusion given in previous sections is

Equation 7.6-7

A flux ratio factor α can be defined as

Equation 7.6-8
Combining Eqs. (7.6-7) and (7.6-8) and integrating for a path length of L cm,

Equation 7.6-9

If the diffusion is equimolar, NA = −NB and Eq. (7.6-7) becomes Fick's law. The molecular diffusivity DAB
is inversely proportional to the total pressure P.

7.6 D. Tr ansition-R e gion Diffu sion of G ase s

As shown in Fig. 7.6-1c, when the mean free path λ and pore diameter are intermediate in size between
the two limits given for Knudsen and molecular diffusion, transition-type diffusion occurs, where
molecule–molecule and molecule–wall collisions are important in diffusion.

The transition-region diffusion equation can be derived by adding the momentum loss due to molecule–
wall collisions in Eq. (7.6-4) and that due to molecule–molecule collisions in Eq. (7.6-7) on a slice of
capillary. No chemical reactions are occurring. The final differential equation is (G1)

Equation 7.6-10

where

Equation 7.6-11

This transition region diffusivity DNA depends slightly on concentration xA.

Integrating Eq. (7.6-10),

Equation 7.6-12

This equation has been shown experimentally to be valid over the entire transition region (R1). It reduces
to the Knudsen equation at low pressures and to the molecular diffusion equation at high pressures. An
equation similar to Eq. (7.6-12) can also be written for component B.

The term DAB/DKA is proportional to 1/P. Hence, as the total pressure P increases, the term DAB/DKA
becomes very small and NA in Eq. (7.6-12) becomes independent of total pressure, since DABP is
independent of P. At low total pressures Eq. (7.6-12) becomes the Knudsen diffusion equation (7.6-5),
and the flux NA becomes directly proportional to P for constant xA1 and xA2.

This is illustrated, in Fig. 7.6-2, for a fixed capillary diameter where the flux increases as total pressure
increases and then levels off at high pressure. The relative position of the curve depends, of course, on the
capillary diameter and the molecular and Knudsen diffusivities. Using only a smaller diameter, DKA
would be smaller, and the Knudsen flux line would be parallel to the existing line at low pressures. At
high pressures the flux line would asymptotically approach the existing horizontal line, since molecular
diffusion is independent of capillary diameter.

Figure 7.6-2. Effect of total pressure P on the diffusion flux NA in the transition region.

If A is diffusing in a catalytic pore and reacts at the surface at the end of the pore so that A → B, then at
steady state, equimolar counterdiffusion occurs, or NA = −NB. Then from Eq. (7.6-8), α = 1 − 1 = 0. The
effective diffusivity DNA from Eq. (7.6-11) becomes

Equation 7.6-13

The diffusivity is then independent of concentration and is constant. Integration of (7.6-10) then gives

Equation 7.6-14
This simplified diffusivity   is often used in diffusion in porous catalysts even when equimolar
counterdiffusion is not occurring. It greatly simplifies the equations for diffusion and reaction to use this
simplified diffusivity.

An alternative simplified diffusivity can be obtained by using an average value of xA in Eq. (7.6-11), to
give

Equation 7.6-15

where xAav  = (xA1 + xA2)/2. This diffusivity is more accurate than  . Integration of Eq. (7.6-10) gives

Equation 7.6-16

7.6 E. Flu x R atios for  Diffu sion of G ase s in C ap illar ie s

1. Diffu sion in op en sy st em

If diffusion in porous solids or channels with no chemical reaction is occurring where the total pressure P
remains constant, then for an open binary counterdiffusing system, the ratio of NA/NB is constant in all
of the three diffusion regimes and is (G1)

Equation 7.6-17

Hence,

Equation 7.6-18

In this case, gas flows past the two open ends of the system. However, when chemical reaction occurs,
stoichiometry determines the ratio NB/NA, and not Eq. (7.6-17).
2. Diffu sion in closed  sy st em

When molecular diffusion is occurring in a closed system, shown in Fig. 6.2-1, at constant total pressure
P, equimolar counterdiffusion occurs.

EXAMPLE 7.6-2. Transition-Region Diffusion of He and N2
A gas mixture at a total pressure of 0.10 atm abs and 298 K is composed of N2 (A) and He (B).

The mixture is diffusing through an open capillary 0.010 m long having a diameter of 5 × 10−6
m. The mole fraction of N2 at one end is xA1 = 0.8 and at the other end is xA2 = 0.2. The

molecular diffusivity DAB is 6.98 × 10−5 m2/s at 1 atm, which is an average value determined
by several investigators.

a.  Calculate the flux NA at steady state.

b.  Use the approximate equations (7.6-14) and (7.6-16) for this case.

S olu t ion: The given values are T = 273 + 25 = 298 K,   = 5 × 10−6/2 = 2.5 × 10−6 m, L = 0.01


m, P = 0.1(1.01325 × 105) = 1.013 × 104 Pa, xA1 = 0.8, xA2 = 0.2, DAB = 6.98 × 10−5 m2/s at 1
atm. Other values needed are MA = 28.02 kg/kg mol, MB = 4.003.

The molecular diffusivity at 0.1 atm is DAB = 6.98 × 10−5/0.1 = 6.98 × 10−4 m2/s.
Substituting into Eq. (7.6-3) for the Knudsen diffusivity,

From Eq. (7.6-17),

From Eq. (7.6-8),

Substituting into Eq. (7.6-12) for part (a),
For part (b), the approximate equation (7.6-13) is used:

Substituting into Eq. (7.6-14), the approximate flux is

Hence, the calculated flux is approximately 40% high when using the approximation of
equimolar counterdiffusion (α = 0).

The more accurate approximate equation (7.6-15) is used next. The average concentration is
xAav  = (xA1 + xA2)/2 = (0.8 + 0.2)/2 = 0.50.

Substituting into Eq. (7.6-16),

In this case the flux is only −1.1% low.

7.6 F. Diffu sion of G ase s in Por ou s S olid s

In actual diffusion in porous solids, the pores are not straight and cylindrical but irregular. Hence, the
equations for diffusion in pores must be modified somewhat for actual porous solids. The problem is
further complicated by the fact that the pore diameters vary and the Knudsen diffusivity is a function of
pore diameter.
As a result of these complications, investigators often measure effective diffusivities DA eff in porous
media, where

Equation 7.6-19

If a tortuosity factor τ is used to correct the length L in Eq. (7.6-16), and the right-hand side is multiplied
by the void fraction ε, Eq. (7.6-16) becomes

Equation 7.6-20

Comparing Eqs. (7.6-19) and (7.6-20),

Equation 7.6-21

In some cases investigators measure DA eff but use   instead of the more accurate   in Eq. (7.6-


21).

Experimental data (G4, S2, S6) show that τ varies from about 1.5 to over 10. A reasonable range for many
commercial porous solids is about 2–6 (S2). If the porous solid consists of a bidispersed system of
micropores and macropores instead of a monodispersed pore system, the above approach should be
modified (C4, S6).

Discussions and references for diffusion in porous inorganic-type solids, organic solids, and freeze-dried
foods such as meat and fruit are given elsewhere (S2, S6).

Another type of diffusion that may occur is surface diffusion. When a molecular layer of adsorption
occurs on the solid, the molecules can migrate on the surface. Details are given elsewhere (S2, S6).
                             
                                                 
                                             
                                               
     

7.7. NUMERICAL METHODS FOR UNSTEADY­STATE MOLECULAR
DIFFUSION

7.7A. Intr od u ction

Unsteady-state diffusion often occurs in inorganic, organic, and biological solid materials. If the
boundary conditions are constant with time, if they are the same on all sides or surfaces of the solid, and
if the initial concentration profile is uniform throughout the solid, the methods described in Section 7.1
can be used. However, these conditions are not always fulfilled, in which case numerical methods must
be used.

7.7B. Unste ad y-S tate  Nu m e r ical M e thod s for  Diffu sion

1. Der iv a t ion for  u nst ea d y  st a t e for  a  sla b

For unsteady-state diffusion in one direction, Eq. (7.1-9) becomes

Equation 7.7-1

Since this equation is identical mathematically to the unsteady-state heat-conduction Eq. (5.10-10),

Equation 5.10-10

identical mathematical methods can be used for solving both diffusion and conduction numerically.

Figure 7.7-1 shows a slab of width Δx centered at point n, represented by the shaded area. Making a mole
balance of A on this slab at the time t when the rate in − rate out = rate of accumulation in Δt s,

Equation 7.7-2

Figure 7.7-1. Unsteady-state diffu sion in a slab.
where A is cross-sectional area and t+Δtcn  is concentration at point n one Δt later. Rearranging,

Equation 7.7-3

where M is a constant.

Equation 7.7-4

As in heat conduction, M ≥ 2.

In using Eq. (7.7-3), the concentration t+ΔtC n  at position n and the new time t + Δt is calculated
explicitly from the known three points at t. In this calculation method, starting with the known
concentrations at t = 0, the calculations proceed directly from one time increment to the next until the
final time is reached.

2. S imp lified  S chmid t  met hod  for  a  sla b

If the value of M = 2, a simplification of Eq. (7.7-3) occurs, giving the Schmidt method:

Equation 7.7-5
7.7C . Bou nd ar y C ond itions for  Nu m e r ical M e thod s for  a S lab

1. C onv ect ion a t  a  b ou nd a r y

For the case where convection occurs outside in the fluid and the concentration of the fluid outside is
suddenly changed to ca , we can make a mass balance on the outside half-slab in Fig. 7.7-1. Following the
methods used for heat transfer to derive Eq. (5.4-7), we write rate of mass entering by convection − rate of
mass leaving by diffusion = rate of mass accumulation in Δt hours:

Equation 7.7-6

where tc1.25 is the concentration at the midpoint of the 0.5 Δx outside slab. As an approximation, using
tc1 for tc1.25 and rearranging Eq. (7.7-6),

Equation 7.7-7

Equation 7.7-8

where kc is the convective mass-transfer coefficient in m/s. Again, note that M ≥ (2N + 2).

2. Insu la t ed  b ou nd a r y  cond it ion

For the insulated boundary at f in Fig. 7.7-1, setting kc = 0 (N = 0) in Eq. (7.7-7), we obtain

Equation 7.7-9

3. Alt er na t iv e conv ect iv e eq u a t ion a t  t he b ou nd a r y

Another form of Eq. (7.7-7) to use if N gets too large can be obtained by neglecting the accumulation in
the front half-slab of Eq. (7.7-6) to give

Equation 7.7-10
The value of M is not restricted by the N value in this equation. When a large number of increments in Δx
are used, the amount of mass neglected is small compared to the total.

4 . Pr oced u r e for  u se of init ia l b ou nd a r y  concent r a t ion

For the first time increment, we should use an average value for 1ca  of (ca  + 0c1)/2, where 0c1 is the initial


concentration at point 1. For succeeding times, the full value of ca  should be used. This special procedure
for the value of ca  increases the accuracy of the numerical method, especially after a few time intervals.

In Section 5.4B, concerning numerical methods for heat-transfer, a detailed discussion is given on the
best value of M to use in Eq. (7.7-3). The most accurate results are obtained for M = 4.

5. Bou nd a r y  cond it ions w it h d ist r ib u t ion coefficient

Equations for boundary conditions in Eqs. (7.7-7) and (7.7-10) were derived for the distribution
coefficient K given in Eq. (7.7-7) being 1.0. When K is not 1.0, as in the boundary conditions for steady
state, Kkc should be substituted for kc in Eq. (7.7-8) to become as follows (see also Sections 6.6B and
7.1C):

Equation 7.7-11

Also, in Eqs. (7.7-7) and (7.7-10), the term ca /K should be substituted for ca .

Other cases, such as for diffusion between dissimilar slabs in series, resistance between slabs in series,
and so on, are covered in detail elsewhere (G1), with actual numerical examples being given. In reference
(G1) the implicit numerical method is discussed.

EXAMPLE 7.7-1. Numerical Solution for Unsteady-State
Diffusion with a Distribution Coefficient
A slab of material 0.004 m thick has an initial concentration profile of solute A as follows,
where x is distance in m from the exposed surface:

x(m) Concentration (kg mol A/m 3 ) Position, n

0 1.0 × 10−3 1 (exposed)

0.001 1.25 × 10−3 2

0.002 1.5 × 10−3 3

0.003 1.75 × 10−3 4

0.004 2.0 × 10−3 5 (insulated)


The diffusivity DAB = 1.0 × 10−9 m2/s. Suddenly, the top surface is exposed to a fluid having a

constant concentration ca  = 6 × 10−3 kg mol A/m3. The distribution coefficient K = ca /cn  =


1.50. The rear surface is insulated, so that unsteady-state diffusion is occurring only in the x
direction. Calculate the concentration profile after 2500 s. The convective mass-transfer
coefficient kc can be assumed as infinite. Use Δx = 0.001 m and M = 2.0.

S olu t ion: Figure 7.7-2 shows the initial concentration profile for four slices and ca  = 6 × 10−3.


Since M = 2, substituting into Eq. (7.7-4) with Δx = 0.001 m and solving for Δt,

Figure 7.7-2. Concentrations for numerical method for unsteady-state diffusion, Example 7.7-1.

Hence, 2500 s/(500 s/increment) or five time increments are needed.

For the front surface, where n = 1, the concentration to use for the first time increment, as
stated previously, is

Equation 7.7-12

where 0c1 is the initial concentration at n = 1. For the remaining time increments,

Equation 7.7-13
To calculate the concentrations for all time increments for slabs n = 2, 3, 4, using Eq. (7.7-5)
for M = 2,

Equation 7.7-14

For the insulated end at n = 5, substituting M = 2 and f = n = 5 into Eq. (7.7-9),

Equation 7.7-15

For 1 Δt or t + 1 Δt, the first time increment, calculating the concentration for n = 1 by Eq. (7.7-
12),

For n = 2, 3, and 4, using Eq. (7.7-14),

For n = 5, using Eq. (7.7-15),

For 2 Δt, using Eq. (7.7-13) for n = 1, using Eq. (7.7-14) for n = 2–4, and using Eq. (7.7-15) for
n = 5,
For 3 Δt,

For 4 Δt,

For 5 Δt,
The final concentration profile is plotted in Fig. 7.7-2. To increase the accuracy, more slab
increments and time increments are needed. This type of calculation is suitable for use with a
computer spreadsheet.
                             
                                                 
                                             
                                               
     

7.8. DIMENSIONAL ANALYSIS IN MASS TRANSFER

7.8A. Intr od u ction

The use of dimensional analysis enables us to predict the various dimensional groups which are very
helpful in correlating experimental mass-transfer data. As we saw for fluid flow and heat transfer, the
Reynolds number, Prandtl number, Grashof number, and Nusselt number are often used in correlating
experimental data. The Buckingham theorem discussed in Sections 3.11 and 4.14 states that the
functional relationship among q quantities or variables whose units may be given in terms of u
fundamental units or dimensions may be written as (q − u) dimensionless groups.

7.8B. Dim e nsional Analysis for  C onv e ctiv e  M ass Tr ansfe r

We consider a case of convective mass transfer where a fluid is flowing by forced convection in a pipe and
mass transfer is occurring from the wall to the fluid. The fluid flows at a velocity ν inside a pipe of

diameter D, and we wish to relate the mass-transfer coefficient   to the variables D, ρ, μ, ν, and DAB.
The total number of variables is q = 6. The fundamental units or dimensions are u = 3 and are mass M,
length L, and time t. The units of the variables are

The number of dimensionless groups of π's are then 6 − 3, or 3. Then,

Equation 7.8-1

We choose the variables DAB, ρ, and D to be the variables common to all the dimensionless groups, which
are

Equation 7.8-2

Equation 7.8-3
Equation 7.8-4

For π1 we substitute the actual dimensions as follows:

Equation 7.8-5

Summing for each exponent,

Equation 7.8-6

Solving these equation simultaneously, a = −1, b = 0, c = 1. Substituting these values into Eq. (7.8-2),

Equation 7.8-7

Repeating for π2 and π3,

Equation 7.8-8

Equation 7.8-9

If we divide π2 by π3 we obtain the Reynolds number:

Equation 7.8-10
Hence, substituting into Eq. (7.8-1),

Equation 7.8-11
                             
                                                 
                                             
                                               
     

7.9. BOUNDARY­LAYER FLOW AND TURBULENCE IN MASS
TRANSFER

7.9 A. Lam inar  Flow  and  Bou nd ar y-Laye r  The or y in M ass Tr ansfe r

In Section 3.10C an exact solution was obtained for the hydrodynamic boundary layer for isothermal
laminar flow past a plate, and in Section 5.7A an extension of the Blasius solution was also used to derive
an expression for convective heat transfer. In an analogous manner we use the Blasius solution for
convective mass transfer for the same geometry and laminar flow. In Fig. 7.9-1 the concentration
boundary layer is shown, where the concentration of the fluid approaching the plate is cA∞ and cAS in the
fluid adjacent to the surface.

Figure 7.9-1. Laminar flow of fluid past a flat plate and concentr ation boundary layer.

We start by using the differential mass balance, Eq. (7.5-17), and simplifying it for steady state where
∂cA/∂t = 0; RA = 0; flow only in the x and y directions, so νz = 0; and neglecting diffusion in the x and z
directions to give

Equation 7.9-1

The momentum boundary-layer equation is very similar:

Equation 3.10-5
The thermal boundary-layer equation is also similar:

Equation 5.7-2

The continuity equation used previously is

Equation 3.10-3

The dimensionless concentration boundary conditions are

Equation 7.9-2

The similarity among the three differential equations (7.9-1), (3.10-5), and (5.7-2) is obvious, as is the
similarity among the three sets of boundary conditions in Eq. (7.9-2). In Section 5.7A the Blasius
solution was applied to convective heat transfer when (μ/ρ)/α = NPr  = 1.0. We use the same type of
solution for laminar convective mass transfer when (μ/ρ)/DAB = NSc = 1.0.

The velocity gradient at the surface was derived previously:

Equation 5.7-5

where NRe,x = xν∞ρ/μ. Also, from Eq. (7.9-2),

Equation 7.9-3
Differentiating Eq. (7.9-3) and combining the result with Eq. (5.7-5),

Equation 7.9-4

The convective mass-transfer equation can be written as follows and related to Fick's equation for dilute
solutions:

Equation 7.9-5

Combining Eqs. (7.9-4) and (7.9-5),

Equation 7.9-6

This relationship is restricted to gases with a NSc = 1.0.

The relationship between the thickness δ of the hydrodynamic and δc of the concentration boundary
layers where the Schmidt number is not 1.0 is

Equation 7.9-7

As a result, the equation for the local convective mass-transfer coefficient is

Equation 7.9-8
We can obtain the equation for the mean mass-transfer coefficient   from x = 0 to x = L for a plate of
width b by integrating as follows:

Equation 7.9-9

The result is

Equation 7.9-10

This is similar to the heat-transfer equation for a flat plate, Eq. (5.7-15), and also agrees with the
experimental mass-transfer equation (7.3-27) for a flat plate.

In Section 3.10 an approximate integral analysis was performed for the laminar hydrodynamic and the
turbulent hydrodynamic boundary layers. This was also done in Section 5.7 for the thermal boundary
layer. An approximate integral analysis can also be done in exactly the same manner for the laminar and
turbulent concentration boundary layers.

7.9 B. Pr and tl M ixing Le ngth and  Tu r b u le nt Ed d y M ass Diffu siv ity

In many applications the flow in mass transfer is turbulent and not laminar. The turbulent flow of a fluid
is quite complex as the fluid undergoes a series of random eddy movements throughout the turbulent
core. When mass transfer is occurring, we refer to this as eddy mass diffusion. In Sections 3.10 and 5.7 we
derived equations for turbulent eddy thermal diffusivity and momentum diffusivity using the Prandtl
mixing length theory.

In a similar manner we can derive a relation for the turbulent eddy mass diffusivity, εM. Eddies are
transported a distance L, called the Prandtl mixing length, in the y direction. At this point L the fluid

eddy differs in velocity from the adjacent fluid by the velocity  , which is the fluctuating velocity

component given in Section 3.10F. The instantaneous rate of mass transfer of A at a velocity   for a
distance L in the y direction is

Equation 7.9-11
where   is the instantaneous fluctuating concentration. The instantaneous concentration of the fluid is 

, where   is the mean value and   the deviation from the mean value. The mixing


length L is small enough that the concentration difference is

Equation 7.9-12

The rate of mass transported per unit area is  . Combining Eqs. (7.9-11) and (7.9-12),

Equation 7.9-13

From Eq. (5.7-23),

Equation 7.9-14

Substituting Eq. (7.9-14) into (7.9-13),

Equation 7.9-15

The term   is called the turbulent eddy mass diffusivity εM. Combining Eq. (7.9-15) with the
diffusion equation in terms of DAB, the total flux is

Equation 7.9-16
The similarities between Eq. (7.9-16) for mass transfer and heat and momentum transfer have been
pointed out in detail in Section 6.1A.

7.9 C . M od e ls for  M ass-Tr ansfe r  C oe fficie nts

1. Int r od u ct ion

For many years mass-transfer coefficients, which were based primarily on empirical correlations, have
been used in the design of process equipment. A better understanding of the mechanisms of turbulence is
needed before we can give a theoretical explanation of convective mass-transfer coefficients. Several
theories of convective mass transfer, such as the eddy diffusivity theory, have been presented in this
chapter. In the following sections we present briefly some of these theories and discuss how they can be
used to extend empirical correlations.

2. Film ma ss-t r a nsfer  t heor y

The film theory, which is the simplest and most elementary theory, assumes the presence of a fictitious
laminar film next to the boundary. This film, where only molecular diffusion is assumed to be occurring,
has the same resistance to mass transfer as actually exists in the viscous, transition, and turbulent core

regions. Then the actual mass-transfer coefficient   is related to this film thickness δf by

Equation 7.9-17

Equation 7.9-18

The mass-transfer coefficient is proportional to  . However, since we have shown that in Eq. (7.3-13)

JD is proportional to (μ/ρDAB)2/3, then  . Hence, the film theory is not correct. The great
advantage of the film theory is its simplicity where it can be used in complex situations such as
simultaneous diffusion and chemical reaction.
3. Penet r a t ion t heor y

The penetration theory derived by Higbie and modified by Danckwerts (D3) was derived for diffusion or
penetration into a laminar falling film for short contact times in Eq. (7.3-23) and is as follows:

Equation 7.9-19

where t L is the time of penetration of the solute in seconds. This was extended by Danckwerts. He
modified this for turbulent mass transfer and postulated that a fluid eddy has a uniform concentration in
the turbulent core and is swept to the surface and undergoes unsteady-state diffusion. Then the eddy is
swept away to the eddy core and other eddies are swept to the surface and stay for a random amount of
time. A mean surface renewal factor s in s−1 is defined as follows:

Equation 7.9-20

The mass-transfer coefficient   is proportional to  . In some systems, such as where liquid flows


over packing and semistagnant pockets occur where the surface is being renewed, the results
approximately follow Eq. (7.9-20). The value of s must be obtained experimentally. Others (D3, T2) have
derived more complex combination film-surface renewal theories predicting a gradual change of the
exponent on DAB from 0.5 to 1.0 depending on turbulence and other factors. Penetration theories have
been used in cases where diffusion and chemical reaction are occurring (D3).

4 . Bou nd a r y -la y er  t heor y

The boundary-layer theory has been discussed in detail in Section 7.9 and is useful in predicting and
correlating data for fluids flowing past solid surfaces. For laminar flow and turbulent flow the mass-

transfer coefficient  . This has been experimentally verified for many cases.
                             
                                                 
                                             
                                               
     

PROBLEMS
7.1-1.
Unst ea d y -S t a t e Diffu sion in a  Thi ck  S la b . Repeat Example 7.1-2 but use a distribution
coefficient K = 0.50 instead of 2.0. Plot the data.
A1: Ans.  c = c  = 5.75 × 10−2 (x = 0), c = 2.78 × 10−2 (x = 0.01 m), c  = 2.87 × 10−2 kg mol/m3
i Li
7.1-2.
Plot  of C oncent r a t ion Pr ofile in Unst ea d y -S t a t e Diffu sion. Using the same conditions
as in Example 7.1-2, calculate the concentration at the points x = 0, 0.005, 0.01, 0.015, and 0.02
m from the surface. Also calculate cLi in the liquid at the interface. Plot the concentrations in a
manner similar to Fig. 7.1-3b, showing interface concentrations.
7.1-3.
Unst ea d y -S t a t e Diffu sion in S ev er a l Dir ect ions. Use the same conditions as in Example
7.1-1 except that the solid is a rectangular block 10.16 mm thick in the x direction, 7.62 mm
thick in the y direction, and 10.16 mm thick in the z direction, and diffusion occurs at all six
faces. Calculate the concentration at the midpoint after 10 h.
A3: Ans.  c = 6.20 × 10−4 kg mol/m3
7.1-4 .
Dr y ing  of M oist  C la y . A very thick slab of clay has an initial moisture content of c0 = 14 wt
%. Air is passed over the top surface to dry the clay. Assume a relative resistance of the gas at the
surface of zero. The equilibrium moisture content at the surface is constant at c1 = 3.0 wt %. The

diffusion of the moisture in the clay can be approximated by a diffusivity of DAB = 1.29 × 10−8

m2/s. After 1.0 h of drying, calculate the concentration of water at points 0.005, 0.01, and 0.02
m below the surface. Assume that the clay is a semi-infinite solid and that the Y value can be
represented using concentrations of wt % rather than kg mol/m3. Plot the values versus x.
7.1-5.
Unst ea d y -S t a t e Diffu sion in a  C y lind er  of Ag a r  G el. A wet cylinder of agar gel at 278 K
containing a uniform concentration of urea of 0.1 kg mol/m3 has a diameter of 30.48 mm and is
38.1 mm long with flat, parallel ends. The diffusivity is 4.72 × 10−10 m2/s. Calculate the
concentration at the midpoint of the cylinder after 100 h for the following cases if the cylinder is
suddenly immersed in turbulent pure water:

a.  For radial diffusion only.

b.  Diffusion occurs radially and axially.

7.1-6 .
Dr y ing  of W ood . A flat slab of Douglas fir wood 50.8 mm thick containing 30 wt % moisture is
being dried from both sides (neglecting ends and edges). The equilibrium moisture content at the
surface of the wood due to the drying air blown over it is held at 5 wt % moisture. The drying can
be assumed to be represented by a diffusivity of 3.72 × 10−6 m2/h. Calculate the time for the
center to reach 10% moisture.
7.2-1.
Flu x a nd  C onv er sion of M a ss-Tr a nsfer  C oefficient . A value of kG was experimentally
determined to be 1.08 lb mol/h · ft 2 · atm for A diffusing through stagnant B. For the same flow

and concentrations it is desired to predict   and the flux of A for equimolar counterdiffusion.
The partial pressures are pA1 = 0.20 atm, pA2 = 0.05 atm, and P = 1.0 atm abs total. Use English
and SI units.
A7:  

Ans.
7.2-2.
C onv er sion of M a ss-Tr a nsfer  C oefficient s. Prove or show the following relationships,
starting with the flux equations:

a.  Convert   to ky  and kG.

b.  Convert kL to kx and  .

c.  Convert kG to ky  and kc.

7.2-3.
Ab sor p t ion of H 2 S  b y  W a t er . In a wetted-wall tower an air–H2S mixture is flowing by a film
of water that is flowing as a thin film down a vertical plate. The H2S is being absorbed from the

air to the water at a total pressure of 1.50 atm abs and 30°C. A value for   of 9.567 × 10−4 m/s
has been predicted for the gas-phase mass-transfer coefficient. At a given point the mole fraction
of H2S in the liquid at the liquid–gas interface is 2.0(10−5) and pA of H2S in the gas is 0.05 atm.
The Henry's law equilibrium relation is pA (atm) = 609xA (mole fraction in liquid). Calculate the
rate of absorption of H2S. (Hint: Call point 1 the interface and point 2 the gas phase. Then
calculate pA1 from Henry's law and the given xA. The value of pA2 is 0.05 atm.)
A9 : Ans.  N  = −1.485 × 10−6 kg mol/s · m2
A
7.2-4 .
Effect  of Hig h Flu x on M a ss-Tr a nsfer  C oefficient s. Using the data from Example 7.2-2,

also calculate the flux ratios   for xA1 = 0.20 and xA1 = 0.01. Tabulate these ratios for the
three values of xA1 and plot the ratio versus xA1.

7.3-1.
M a ss Tr a nsfer  fr om a  Fla t  Pla t e t o a  Liq u id . Using the data and physical properties of
Example 7.3-2 calculate the flux for a water velocity of 0.152 m/s and a plate length of L = 0.137
m. Do not assume that xBM = 1.0 but actually calculate its value.
7.3-2.
M a ss Tr a nsfer  fr om a  Pip e W a ll. Pure water at 26.1°C is flowing at a velocity of 0.0305 m/s
in a tube having an inside diameter of 6.35 mm. The tube is 1.829 m long, with the last 1.22 m
having the walls coated with benzoic acid. Assuming that the velocity profile is fully developed,
calculate the average concentration of benzoic acid at the outlet. Use the physical property data
from Example 7.3-2. [Hint: First calculate the Reynolds number Dνρ/μ. Then calculate
NReNSc(D/L)(π/4), which is the same as W/DABρL.]
A12: Ans.  (c  − c )/(c  − c ) = 0.0744, c  = 2.193 × 10−3 kg mol/m3
A A0 Ai A0 A
7.3-3.
M a ss-Tr a nsfer  C oefficient  for  Va r iou s G eomet r ies. It is desired to estimate the mass-
transfer coefficient kG in kg mol/s · m2· Pa for water vapor in air at 338.6 K and 101.32 kPa
flowing in a large duct past solids of different geometries. The velocity in the duct is 3.66 m/s.
The water vapor concentration in the air is small, so the physical properties of air can be used.
Water vapor is being transferred to the solids. Do this for the following geometries:

a.  A single 25.4-mm-diameter sphere.

b.  A packed bed of 25.4-mm spheres with ε = 0.35.

A13: Ans.  (a) k  = 1.984 × 10−8 kg mol/s · m2· Pa (1.482 lb mol/h · ft 2· atm)


G
7.3-4 .
M a ss Tr a nsfer  t o Definit e S ha p es. Estimate the value of the mass-transfer coefficient in a
stream of air at 325.6 K flowing in a duct past the following shapes made of solid naphthalene.
The velocity of the air is 1.524 m/s at 325.6 K and 202.6 kPa. The DAB of naphthalene in air is

5.16 × 10−6 m2/s at 273 K and 101.3 kPa.

a.  For air flowing parallel to a flat plate 0.152 m in length.

b.  For air flowing past a single sphere 12.7 mm in diameter.

7.3-5.
M a ss Tr a nsfer  t o Pa ck ed  Bed  a nd  Dr iv ing  For ce. Pure water at 26.1°C is flowing at a rate
of 0.0701 ft 3/h through a packed bed of 0.251-in. benzoic-acid spheres having a total surface
area of 0.129 ft 2. The solubility of benzoic acid in water is 0.00184 lb mol benzoic acid/ft 3
solution. The outlet concentration cA2 is 1.80 × 10−4 lb mol/ft 3. Calculate the mass-transfer
coefficient kc.

7.3-6 .
M a ss Tr a nsfer  in Liq u id  M et a ls. Mercury at 26.5°C is flowing through a packed bed of lead
spheres having a diameter of 2.096 mm with a void fraction of 0.499. The superficial velocity is
0.02198 m/s. The solubility of lead in mercury is 1.721 wt %, the Schmidt number is 124.1, the
viscosity of the solution is 1.577 × 10−3 Pa · s, and the density is 13 530 kg/m3.

a.  Predict the value of JD. Use Eq. (7.3-38) if applicable. Compare with the experimental
value of JD = 0.076 (D2).

b.  Predict the value of kc for the case of A diffusing through nondiffusing B.

A16 : Ans.  (a) J  = 0.0784; (b) k  = 6.986 × 10−5 m/s


D c
7.3-7.
M a ss Tr a nsfer  fr om a  Pip e a nd  Log  M ea n Dr iv ing  For ce. Use the same physical
conditions as in Problem 7.3-2, but the velocity in the pipe is now 3.05 m/s. Do as follows:

a.  Predict the mass-transfer coefficient  . (Is this turbulent flow?)


b.  Calculate the average benzoic acid concentration at the outlet. [Note: In this case, Eqs.
(7.3-42) and (7.3-43) must be used with the log mean driving force, where A is the surface
area of the pipe.]

c.  Calculate the total kg mol of benzoic acid dissolved per second.

7.3-8.
Der iv a t ion of R ela t ion Bet w een J D  a nd  N Sh . Equation (7.3-3) defines the Sherwood
number and Eq. (7.3-5) defines the JD factor. Derive the relation between NSh and JD in terms of
NRe and NSc.
A18:  

Ans.
7.3-9 .
Dr iv ing  For ce t o Use in M a ss Tr a nsfer . Derive Eq. (7.3-42) for the log mean driving force to
use for a fluid flowing in a packed bed or in a tube. (Hint: Start by making a mass balance and a
diffusion rate balance over a differential area dA as follows:

where V = m3/s flow rate. Assume dilute solutions.)
7.4 -1.
M a ximu m Oxy g en Up t a k e of a  M icr oor g a nism. Calculate the maximum possible rate of

oxygen uptake at 37°C of microorganisms having a diameter of   μm suspended in an agitated
aqueous solution. It is assumed that the surrounding liquid is saturated with O2 from air at 1
atm abs pressure. It will be assumed that the microorganism can utilize the oxygen much faster
than it can diffuse to it. The microorganism has a density very close to that of water. Use
physical-property data from Example 7.4-1. (Hint: Since the oxygen is consumed faster than it
is supplied, the concentration cA2 at the surface is zero. The concentration cA1 in the solution is
at saturation.)

A20: Ans.  k  = 9.75 × 10−3 m/s, N  = 2.20 × 10−6 kg mol O /s · m2


c A 2
7.4 -2.
M a ss Tr a nsfer  of O 2  in Fer ment a t ion Pr ocess. A total of 5.0 g of wet microorganisms

having a density of 1100 kg/m3 and a diameter of 0.667 μm are added to 0.100 L of aqueous
solution at 37°C in a shaker flask for a fermentation. Air can enter through a porous stopper. Use
physical property data from Example 7.4-1.

a.  Calculate the maximum rate possible for mass transfer of oxygen in kg mol O2/s to the
surface of the microorganisms, assuming that the solution is saturated with air at 101.32
kPa abs pressure.

b.  By material balances on other nutrients, the actual utilization of O2 by the

microorganisms is 6.30 × 10−6 kg mol O2/s. What would be the actual concentration of
O2 in the solution as percent saturation during the fermentation?
A21:  (a)   = 9.82 × 10  m/s,   = 9.07 × 10  kgmol O /s; (b) 6.95% saturation

Ans. −3 NAA −5
2
7.5-1.
S u m of M ola r  Flu xes. Prove the following equation using the definitions in Table 7.5-1:

7.5-2.
Pr oof of Der iv ed  R ela t ion. Using the definitions from Table 7.5-1, prove the following:

7.5-3.
Differ ent  For ms of Fick 's La w . Using Eq. (1), prove Eq. (2):

Equation 1

Equation 2

(Hint: First relate w A to xA. Then differentiate this equation to relate dw A and dxA. Finally, use


M = xAMA + xBMB to simplify.)

7.5-4 .
Ot her  For m of Fick 's La w . Show that the following form of Fick's law is valid:

(  Start with  . Substitute the expression for   from   and

Hint: Table 7.5-1
simplify.)
7.5-5.
Differ ent  For m of Eq u a t ion of C ont inu it y . Starting with Eq. (7.5-12),

Equation 7.5-12
convert this to the following for constant ρ:

Equation 1

[Hint: From Table 7.5-1, substitute n A = j A + ρAν into Eq. (7.5-12). Note that (∇ · ν) = 0 for


constant ρ. Then substitute Fick's law in terms of j A.]
7.5-6 .
Diffu sion a nd  R ea ct ion a t  a  S u r fa ce. Gas A is diffusing from a gas stream at point 1 to a
catalyst surface at point 2 and reacts instantaneously and irreversibly as follows:

Gas B diffuses back to the gas stream. Derive the final equation for NA at constant pressure P and
steady state in terms of partial pressures.

A27:  

Ans.
7.5-7.
Unst ea d y -S t a t e Diffu sion a nd  R ea ct ion. Solute A is diffusing at unsteady state into a
semi-infinite medium of pure B and undergoes a first-order reaction with B. Solute A is dilute.
Calculate the concentration cA at points z = 0, 4, and 10 mm from the surface for t = 1 × 105 s.

Physical property data are DAB = 1 × 10−9 m2/s, k' = 1 × 10−4 s−1, cA0 = 1.0 kg mol/m3. Also

calculate the kg mol absorbed/m2.
7.5-8.
M u lt icomp onent  Diffu sion. At a total pressure of 202.6 kPa and 358 K, ammonia gas (A) is
diffusing at steady state through an inert, nondiffusing mixture of nitrogen (B) and hydrogen
(C). The mole fractions at z1 = 0 are xA1 = 0.8, xB1 = 0.15, and xC1 = 0.05; and at z2 = 4.0 mm,
xA2 = 0.2, xB2 = 0.6, and xC2 = 0.2. The diffusivities at 358 K and 101.3 kPa are DAB = 3.28 ×

10−5 m2/s and DAC = 1.093 × 10−4 m2/s. Calculate the flux of ammonia.
A29 : Ans.  N  = 4.69 × 10−4 kg mol A/s · m2
A
7.5-9 .
Diffu sion in Liq u id  M et a ls a nd  Va r ia b le Diffu siv it y . The diffusion of tin (A) in liquid
lead (B) at 510°C was carried out by using a 10.0-mm-long capillary tube and maintaining the
mole fraction of tin at xA1 at the left end and xA2 at the right end of the tube. In the range of
concentrations of 0.2 ≤ xA ≤ 0.4 the diffusivity of tin in lead has been found to be a linear
function of xA (S7):

where A and B are constants and D  is in m2/s.
AB

a.  Assuming the molar density to be constant at c = cA + cB = cav , derive the final integrated


equation for the flux NA, assuming steady state and that A diffuses through stagnant B.

b.  For this experiment, A = 4.8 × 10−9, B = −6.5 × 10−9, cav  = 50 kg mol/m3, xA1 = 0.4, xA2


= 0.2. Calculate NA.

A30: Ans.  (b) N  = 4.055 × 10−6 kg mol A/s · m2


A
7.5-10.
Diffu sion a nd  C hemica l R ea ct ion of M olt en Ir on in Pr ocess M et a llu r g y . In a
steelmaking process using molten pig iron containing carbon, a spray of molten iron particles
containing 4.0 wt % carbon falls through a pure-oxygen atmosphere. The carbon diffuses
through the molten iron to the surface of the drop, where it is assumed that it reacts instantly at
the surface because of the high temperature, as follows, according to a first-order reaction:

Calculate the maximum drop size allowable so that the final drop after a 2.0-s fall contains an
average of 0.1 wt % carbon. Assume that the mass-transfer rate of gases at the surface is very
great, so there is no outside resistance. Assume no internal circulation of the liquid. Hence, the
decarburization rate is controlled by the rate of diffusion of carbon to the surface of the droplet.
The diffusivity of carbon in iron is 7.5 × 10−9 m2/s (S7). (Hint:  Can Fig. 5.3-13 be used for this
case?)
A31:Ans. radius = 0.217 mm
7.5-11.
Effect  of S low  R ea ct ion R a t e on Diffu sion. Gas A diffuses from point 1 to a catalyst surface
at point 2, where it reacts as follows: 2A → B. Gas B diffuses back a distance δ to point 1.

a.  Derive the equation for NA for a very fast reaction using mole fraction units xA1, and so on.

b.  For DAB = 0.2 × 10−4 m2/s, xA1 = 0.97, P = 101.32 kPa, δ = 1.30 mm, and T = 298 K, solve
for NA.

c.  Do the same as in part (a) but for a slow first-order reaction where   is the reaction


velocity constant.

d.  Calculate NA and xA2 for part (c) where   = 0.53 × 10−2 m/s.

A32: Ans.  (b) N  = 8.35 × 10−4 kg mol/s · m2


A
7.5-12.
Diffu sion a nd  Het er og eneou s R ea ct ion on S u r fa ce. In a tube of radius R m filled with a
liquid, dilute component A is diffusing in the nonflowing liquid phase represented by

where z is distance along the tube axis. The inside wall of the tube exerts a catalytic effect and
decomposes A so that the heterogeneous rate of decomposition on the wall in kg mol A/s is equal
to kc A , where k is a first-order constant and A  is the wall area in m2. Neglect any radial
A w w
gradients (this means a uniform radial concentration).

Derive the differential equation for unsteady state for diffusion and reaction for this system.
[Hint: First make a mass balance for A for a Δz length of tube as follows: rate of input (diffusion)
+ rate of generation (heterogeneous) = rate of output (diffusion) + rate of accumulation.]
A33:  

Ans.
7.6 -1.
K nu d sen Diffu siv it ies. A mixture of He (A) and Ar (B) is diffusing at 1.013 × 105 Pa total
pressure and 298 K through a capillary having a radius of 100 Å.

a.  Calculate the Knudsen diffusivity of He (A).

b.  Calculate the Knudsen diffusivity of Ar (B).

c.  Compare with the molecular diffusivity DAB.

A34 : Ans.  (a) D  = 8.37 × 10−6 m2/s; (c) D  = 7.29 × 10−5 m2/s


KA AB
7.6 -2.
Tr a nsit ion-R eg ion Diffu sion. A mixture of He (A) and Ar (B) at 298 K is diffusing through
an open capillary 15 mm long with a radius of 1000 Å. The total pressure is 1.013 × 105 Pa. The
molecular diffusivity DAB at 1.013 × 105 Pa is 7.29 × 10−5 m2/s.

a.  Calculate the Knudsen diffusivity of He (A).

b.  Predict the flux NA using Eq. (7.6-18) and Eq. (7.6-12) if xA1 = 0.8 and xA2 = 0.2. Assume
steady state.

c.  Predict the flux NA using the approximate Eqs. (7.6-14) and (7.6-16).

7.6 -3.
Diffu sion in a  Por e in t he Tr a nsit ion R eg ion. Pure H2 gas (A) at one end of a noncatalytic
pore of radius 50 Å and length 1.0 mm (xA1 = 1.0) is diffusing through this pore with pure C 2H6
gas (B) at the other end at xA2 = 0. The total pressure is constant at 1013.2 kPa. The predicted

molecular diffusivity of H2–C 2H6 is 8.60 × 10−5 m2/s at 101.32 kPa and 373 K. Calculate the
Knudsen diffusivity of H2 and flux NA of H2 in the mixture at 373 K and steady state.
A36 : Ans.  D  = 6.60 × 10−6 m2/s, N  = 1.472 × 10−3 kg mol A/s · m2
KA A
7.6 -4 .
Tr a nsit ion-R eg ion Diffu sion in C a p illa r y . A mixture of nitrogen gas (A) and helium (B) at
298 K is diffusing through a capillary 0.10 m long in an open system with a diameter of 10 μm.
The mole fractions are constant at xA1 = 1.0 and xA2 = 0. See Example 7.6-2 for physical
properties.

a.  Calculate the Knudsen diffusivity DKA and DKB at the total pressures of 0.001, 0.1, and
10.0 atm.

b.  Calculate the flux NA at steady state at these pressures.

c.  Plot NA versus P on log–log paper. What are the limiting lines at lower pressures and very
high pressures? Calculate and plot these lines.

7.7-1.
Nu mer ica l M et hod  for  Unst ea d y -S t a t e Diffu sion. A solid slab 0.01 m thick has an initial
uniform concentration of solute A of 1.00 kg mol/m3. The diffusivity of A in the solid is DAB = 1.0

× 10−10 m2/s. All surfaces of the slab are insulated except the top surface. The surface
concentration is suddenly dropped to zero concentration and held there. Unsteady-state
diffusion occurs in the one x direction with the rear surface insulated. Using a numerical
method, determine the concentrations after 12 × 104 s. Use Δx = 0.002 m and M = 2.0. The value
of K is 1.0.
A38:Ans. c1 = 0 (front surface, x = 0 m)

c2 = 0.3125 kg mol/m3 (x = 0.002 m)

c3 = 0.5859 (x = 0.004 m)

c4 = 0.7813 (x = 0.006 m)

c5 = 0.8984 (x = 0.008 m)

c6 = 0.9375 (insulated surface, x = 0.01 m)
7.7-2.
Dig it a l C omp u t er  a nd  Unst ea d y -S t a t e Diffu sion. Using the conditions of Problem 7.7-1,
solve that problem by digital computer. Use Δx = 0.0005 m. Write the spreadsheet program and
plot the final concentrations. Use the explicit method, M = 2.
7.7-3.
Nu mer ica l M et hod  a nd  Differ ent  Bou nd a r y  C ond it ion. Use the same conditions as for
Example 7.7-1, but in this case the rear surface is not insulated. At time t = 0 the concentration
at the rear surface is also suddenly changed to c5 = 0 and held there. Calculate the concentration
profile after 2500 s. Plot the initial and final concentration profiles and compare with the final
profile of Example 7.7-1.
7.8-1.
Dimensiona l Ana ly sis in M a ss Tr a nsfer . A fluid is flowing in a vertical pipe and mass
transfer is occurring from the pipe wall to the fluid. Relate the convective mass-transfer

coefficient   to the variables D, ρ, μ, ν, DAB, g, and Δρ, where D is pipe diameter, L is pipe
length, and Δρ is the density difference.
A4 1:
 

Ans.
7.9 -1.
M a ss Tr a nsfer  a nd  Tu r b u lence M od els. Pure water at a velocity of 0.11 m/s is flowing at
26.1°C past a flat plate of solid benzoic acid where L = 0.40 m. Do as follows:

a.  Assuming dilute solutions, calculate the mass-transfer coefficient kc. Use physical-
property data from Example 7.3-2.

b.  Using the film model, calculate the equivalent film thickness.

c.  Using the penetration model, calculate the time of penetration.

d.  Calculate the mean surface renewal factor using the modified penetration model.

A4 2: Ans.  (b) δ  = 0.2031 mm; (d) s = 3.019 × 10−2 s−1


f
                             
                                                 
                                             
                                               
     

Part 2: Separation Process Principles (Includes Unit Operations)
Evaporation

Drying of Process Materials

Stage and Continuous Gas–Liquid Separation Processes

Vapor–Liquid Separation Processes

Liquid–Liquid and Fluid–Solid Separation Processes

Membrane Separation Processes

Mechanical–Physical Separation Processes

Fundamental Constants and Conversion Factors

Physical Properties of Water

Physical Properties of Inorganic and Organic Compounds

Physical Properties of Foods and Biological Materials

Properties of Pipes, Tubes, and Screens

Notation

About the Author
                             
                                                 
                                             
                                               
     

Chapter 8. Evaporation
INTRODUCTION

TYPES OF EVAPORATION EQUIPMENT AND OPERATION METHODS

OVERALL HEAT-TRANSFER COEFFICIENTS IN EVAPORATORS

CALCULATION METHODS FOR SINGLE-EFFECT EVAPORATORS

CALCULATION METHODS FOR MULTIPLE-EFFECT EVAPORATORS

CONDENSERS FOR EVAPORATORS

EVAPORATION OF BIOLOGICAL MATERIALS

EVAPORATION USING VAPOR RECOMPRESSION

PROBLEMS

REFERENCES
                             
                                                 
                                             
                                               
     

8.1. INTRODUCTION

8.1A. Pu r p ose

In Section 4.8 we discussed the case of heat transfer to a boiling liquid. An important instance of this
type of heat transfer occurs quite often in the process industries and is given the general name
evaporation. In evaporation the vapor from a boiling liquid solution is removed and a more concentrated
solution remains. In the majority of cases the separation process called evaporation refers to the removal
of water from an aqueous solution.

Typical examples of evaporation are concentration of aqueous solutions of sugar, sodium chloride,
sodium hydroxide, glycerol, glue, milk, and orange juice. In these cases the concentrated solution is the
desired product and the evaporated water is normally discarded. In a few cases, water, which contains a
small amount of minerals, is evaporated to give a solids-free water to be used as boiler feed, for special
chemical processes, or for other purposes. Evaporation processes to evaporate seawater to provide
drinking water have been developed and used. In some cases, the primary purpose of evaporation is to
concentrate a solution so that upon cooling, salt crystals will form and be separated. This special
evaporation process, termed crystallization, is discussed in Chapter 12.

8.1B. Pr oce ssing Factor s

The physical and chemical properties of the solution being concentrated and of the vapor being removed
bear greatly on the type of evaporator used and the pressure and temperature of the process. Some of the
properties which affect the processing methods are discussed next.

1. C oncent r a t ion in t he  liq u id

Usually, the liquid feed to an evaporator is relatively dilute, so its viscosity is low, similar to that of
water, and relatively high heat-transfer coefficients are obtained. As evaporation proceeds, the solution
may become very concentrated and quite viscous, causing the heat-transfer coefficient to drop markedly.
Adequate circulation and/or turbulence must be present to keep the coefficient from becoming too low.

2. S olu b ilit y

As solutions are heated and the concentration of the solute or salt increases, the solubility limit of the
material in solution may be exceeded and crystals may form. This may limit the maximum concentration
in solution which can be obtained by evaporation. In Fig. 8.1-1 some solubilities of typical salts in water
are shown as a function of temperature. In most cases the solubility of the salt increases with
temperature. This means that when a hot, concentrated solution from an evaporator is cooled to room
temperature, crystallization may occur.

Figure 8.1-1. Solubility  curves for some ty pical salts  in water.


3. Temp er a t u r e sensit iv it y  of ma t er ia ls

Many products, especially food and other biological materials, may be temperature-sensitive and
degrade at higher temperatures or after prolonged heating. Such products include pharmaceutical
products; food products such as milk, orange juice, and vegetable extracts; and fine organic chemicals.
The amount of degradation is a function of the temperature and the length of time.

4 . Foa ming  or  fr ot hing

In some cases materials composed of caustic solutions, food solutions such as skim milk, and some
fatty-acid solutions form a foam or froth during boiling. This foam accompanies the vapor coming out of
the evaporator and entrainment losses occur.

5. Pr essu r e a nd  t emp er a t u r e

The boiling point of the solution is related to the pressure of the system. The higher the operating
pressure of the evaporator, the higher the temperature at boiling. Also, as the concentration of the
dissolved material in solution increases by evaporation, the temperature of boiling may rise. This
phenomenon is called boiling-point rise or elevation and is discussed in Section 8.4. To keep the
temperatures low in heat-sensitive materials, it is often necessary to operate under 1 atm pressure, that
is, under vacuum.

6 . S ca le d ep osit ion a nd  ma t er ia ls of const r u ct ion

Some solutions deposit solid materials called scale on the heating surfaces. These could be formed by
decomposition products or by decreases in solubility. The result is that the overall heat-transfer
coefficient decreases, and the evaporator must eventually be cleaned. The materials used in construction
of the evaporator should be chosen to minimize corrosion.
                             
                                                 
                                             
                                               
     

8.2. TYPES OF EVAPORATION EQUIPMENT AND OPERATION
METHODS

8.2A. G e ne r al Typ e s of Ev ap or ator s

In evaporation, heat is added to a solution to vaporize the solvent, which is usually water. The heat is
generally provided by the condensation of a vapor such as steam on one side of a metal surface, with the
evaporating liquid on the other side. The type of equipment used depends primarily on the configuration
of the heat-transfer surface and on the means employed to provide agitation or circulation of the liquid.
The general types of equipment are discussed below.

1. Op en k et t le or  p a n

The simplest evaporator consists of an open pan or kettle in which the liquid is boiled. The heat is
supplied by condensation of steam in a jacket or in coils immersed in the liquid. In some cases the kettle
is direct-fired. These evaporators are inexpensive and simple to operate, but the heat economy is poor. In
some cases, paddles or scrapers are used for agitation.

2. Hor izont a l-t u b e na t u r a l cir cu la t ion ev a p or a t or

The horizontal-tube natural circulation evaporator is shown in Fig. 8.2-1a. The horizontal bundle of
heating tubes is similar to the bundle of tubes in a heat exchanger. The steam enters the tubes, where it
condenses. The steam condensate leaves at the other end of the tubes. The boiling liquid solution covers
the tubes. The vapor leaves the liquid surface, often goes through some de-entraining device such as a
baffle to prevent carryover of liquid droplets, and leaves out the top. This type of evaporator is relatively
cheap and is used for nonviscous liquids with high heat-transfer coefficients and liquids that do not
deposit scale. Since liquid circulation is poor, they are unsuitable for viscous liquids. In almost all cases,
this evaporator and the types discussed below are operated continuously, that is, the feed enters at a
constant rate and the concentrate leaves at a constant rate.

Figure 8.2-1. Diffe rent ty pes of evaporators: (a) horizontal-tube ty pe, (b) vertical-tube ty pe, (c) long-tube


vertical ty pe, (d) forced-circulation ty pe.
3. Ver t ica l-t y p e na t u r a l cir cu la t ion ev a p or a t or

In this type of evaporator, vertical rather than horizontal tubes are used; the liquid is inside the tubes
and the steam condenses outside the tubes. Because of boiling and decreases in density, the liquid rises
in the tubes by natural circulation, as shown in Fig. 8.2-1b, and flows downward through a large, central
open space or downcomer. This natural circulation increases the heat-transfer coefficient. This type of
evaporator is not used with viscous liquids. It is often called the short-tube evaporator. A variation is the
basket type, where vertical tubes are used but the heating element is held suspended in the body so there
is an annular open space as the downcomer. In this way, it differs from the vertical natural circulation
evaporator, which has a central instead of annular open space as the downcomer. The basket type is
widely used in the sugar, salt, and caustic-soda industries.

4 . Long -t u b e v er t ica l-t y p e ev a p or a t or

Since the heat-transfer coefficient on the steam side is very high compared to that on the evaporating-
liquid side, high liquid velocities are desirable. In a long-tube vertical-type evaporator, shown in Fig. 8.2-
1c, the liquid is inside the tubes. The tubes are 3 to 10 m long and the formation of vapor bubbles inside
the tubes causes a pumping action, which gives quite high liquid velocities. Generally, the liquid passes
through the tubes only once and is not recirculated. Contact times can be quite low in this type. In some
cases, as when the ratio of feed to evaporation rate is low, natural recirculation of the product through
the evaporator is effected by adding a large pipe connection between the outlet concentrate line and the
feed line. This is widely used for producing condensed milk.

5. Fa lling -film-t y p e ev a p or a t or

A variation on the long-tube-type evaporator is the falling-film evaporator, wherein the liquid is fed to
the top of the tubes and flows down the walls as a thin film. Vapor-liquid separation usually takes place
at the bottom. This type is widely used for concentrating heat-sensitive materials such as orange juice
and other fruit juices, because the holdup time is very small (5 to 10 s or more) and the heat-transfer
coefficients are high.

6 . For ced -cir cu la t ion-t y p e ev a p or a t or

The liquid-film heat-transfer coefficient can be increased by pumping to cause forced circulation of the
liquid inside the tubes. This could be done in the long-tube vertical type shown in Fig. 8.2-1c by adding a
pipe connection shown with a pump between the outlet concentrate line and the feed line. In the forced-
circulation type, however, the vertical tubes are usually shorter than in the long-tube type, as shown in
Fig. 8.2-1d. Additionally, in some cases a separate and external horizontal heat exchanger is used. This
type of evaporator is very useful for viscous liquids.

7. Ag it a t ed -film ev a p or a t or

The main resistance to heat transfer in an evaporator is on the liquid side. One way to increase turbulence
in this film, and hence the heat-transfer coefficient, is by actual mechanical agitation of this liquid film.
This is done in a modified falling-film evaporator with only a single, large, jacketed tube containing an
internal agitator. Liquid enters at the top of the tube and as it flows downward, it is spread out into a
turbulent film by the vertical agitator blades. The concentrated solution leaves at the bottom and vapor
leaves through a separator and out the top. This type of evaporator is very useful with highly viscous
materials, since the heat-transfer coefficient is greater than in forced-circulation evaporators. It is used
with heat-sensitive viscous materials such as rubber latex, gelatin, antibiotics, and fruit juices. However,
it has a high cost and small capacity. For interested readers, Perry and Green (P1) give more-detailed
discussions and descriptions of evaporation equipment.

8. Op en-p a n sola r  ev a p or a t or

A very old yet still-used process is solar evaporation in open pans. Saltwater is put in shallow open pans
or troughs and allowed to evaporate slowly in the sun to crystallize the salt.

8.2B. M e thod s of Op e r ation of Ev ap or ator s

1. S ing le-effect  ev a p or a t or s

A simplified diagram of a single-stage or single-effect evaporator is given in Fig. 8.2-2. The feed enters at
TF K and saturated steam at Ts enters the heat-exchange section. Condensed steam leaves as condensate
or drips. Since the solution in the evaporator is assumed to be completely mixed, the concentrated
product and the solution in the evaporator have the same composition and temperature T1, which is the
boiling point of the solution. The temperature of the vapor is also T1, since it is in equilibrium with the
boiling solution. The pressure is P1, which is the vapor pressure of the solution at T1.
Figure 8.2-2. Simplified diagram of single-effect evaporator.

If the solution to be evaporated is assumed to be dilute and like water, then 1 kg of steam condensing will
evaporate approximately 1 kg of vapor. This will hold if the feed entering has a temperature TF near the
boiling point.

The concept of an overall heat-transfer coefficient is used in the calculation of the rate of heat transfer in
an evaporator. The general equation can be written

Equation 8.2-1

where q is the rate of heat transfer in W (btu/h), U is the overall heat-transfer coefficient in W/m2 · K
(btu/h · ft 2 · °F), A is the heat-transfer area in m2 (ft 2), Ts is the temperature of the condensing steam in
K (°F), and T1 is the boiling point of the liquid in K (°F).

Single-effect evaporators are often used when the required capacity of operation is relatively small and/or
the cost of steam is relatively cheap compared to the evaporator cost. However, for large-capacity
operation, using more than one effect will markedly reduce steam costs.

2. For w a r d -feed  mu lt ip le-effect  ev a p or a t or s

A single-effect evaporator as shown in Fig. 8.2-2 is wasteful of energy, since the latent heat of the vapor
leaving is not used but is discarded. Much of this latent heat, however, can be recovered and reused by
employing a multiple-effect evaporator. A simplified diagram of a forward-feed triple-effect evaporation
system is shown in Fig. 8.2-3.

Figure 8.2-3. Simplified diagram of forward-feed triple-effect evaporator.
If the feed to the first effect is near the boiling point at the pressure in the first effect, 1 kg of steam will
evaporate almost 1 kg of water. The first effect operates at a temperature that is high enough that the
evaporated water serves as the heating medium to the second effect. Here, again, almost another kg of
water is evaporated, which can then be used as the heating medium to the third effect. As a very rough
approximation, almost 3 kg of water will be evaporated for 1 kg of steam in a three-effect evaporator.
Hence, the steam economy, which is kg vapor evaporated/kg steam used, is increased. This also holds
approximately for more than three effects. However, the increased steam economy of a multiple-effect
evaporator is gained at the expense of the original first cost of these evaporators.

In forward-feed operation as shown in Fig. 8.2-3, the fresh feed is added to the first effect and flows to the
next in the same direction as the vapor flow. This method of operation is used when the feed is hot or
when the final concentrated product might be damaged at high temperatures. The boiling temperatures
decrease from effect to effect. This means that if the first effect is at P1 = 1 atm abs pressure, the last effect
will be under vacuum at a pressure P3.

3. Ba ck w a r d -feed  mu lt ip le-effect  ev a p or a t or s

In the backward-feed operation shown in Fig. 8.2-4 for a triple-effect evaporator, the fresh feed enters the
last and coldest effect and continues on until the concentrated product leaves the first effect. This
method of reverse feed is advantageous when the fresh feed is cold, since a smaller amount of liquid must
be heated to the higher temperatures in the second and first effects. However, liquid pumps must be used
in each effect, since the flow is from low to high pressure. This reverse-feed method is also used when the
concentrated product is highly viscous. The high temperatures in the early effects reduce the viscosity
and give reasonable heat-transfer coefficients.

Figure 8.2-4. Simplified diagram of backward-feed triple-effect evaporator.
4 . Pa r a llel-feed  mu lt ip le-effect  ev a p or a t or s

Parallel feed in multiple-effect evaporators involves the adding of fresh feed and withdrawal of
concentrated product from each effect. The vapor from each effect is still used to heat the next effect. This
method of operation is mainly used when the feed is almost saturated and solid crystals are the product,
as in the evaporation of brine to make salt.
                             
                                                 
                                             
                                               
     

8.3. OVERALL HEAT­TRANSFER COEFFICIENTS IN EVAPORATORS
The overall heat-transfer coefficient U in an evaporator is composed of the steam-side condensing
coefficient, which has a value of about 5700 W/m2 · K (1000 btu/h · ft 2 · °F); the metal wall, which has a
high thermal conductivity and usually a negligible resistance; the resistance of the scale on the liquid
side; and the liquid film coefficient, which is usually inside the tubes.

The steam-side condensing coefficient outside the tubes can be estimated using Eq. (4.8-20) through
(4.8-26). The resistance due to scale formation usually cannot be predicted. Increasing the velocity of the
liquid in the tubes greatly decreases the rate of scale formation, which is one important advantage of
forced-circulation evaporators. The scale may be salts, such as calcium sulfate or sodium sulfate, which
decrease in solubility with an increase in temperature and hence tend to deposit on the hot tubes.

For forced-circulation evaporators the coefficient h inside the tubes can be predicted if there is little or no
vaporization inside the tube. The liquid hydrostatic head in the tubes prevents most boiling in the tubes.
The standard equations for predicting the h value of liquids inside tubes can be used. Velocities used
often range from 2 to 5 m/s (7 to 15 ft/s). The heat-transfer coefficient can be predicted from Eq. (4.5-8),
using a constant of 0.028 instead of 0.027 (B1). If there is some or appreciable boiling in part or all of the
tubes, use of the equation assuming no boiling will give conservative safe results (P1).

For long-tube vertical natural-circulation evaporators the heat-transfer coefficient is more difficult to
predict, since there is a nonboiling zone in the bottom of the tubes and a boiling zone in the top. The
length of the nonboiling zone depends on the heat transfer in the two zones and the pressure drop in the
boiling two-phase zone. The film heat-transfer coefficient in the nonboiling zone can be estimated using
Eq. (4.5-8) with a constant of 0.028. For the boiling two-phase zone, a number of equations are given by
Perry and Green (P2).

For short-tube vertical evaporators the heat-transfer coefficients can be estimated by using the same
methods as for long-tube vertical natural-circulation evaporators. Horizontal-tube evaporators have
heat-transfer coefficients on the same order of magnitude as short-tube vertical evaporators.

For the agitated-film evaporator, the heat-transfer coefficient may be estimated using Eq. (4.13-4) for a
scraped surface heat exchanger.

The methods given above are useful for actual evaporator design and/or for evaluating the effects of
changes in operating conditions on the coefficients. In making preliminary designs or cost estimates, it is
helpful to have available overall heat-transfer coefficients usually encountered in commercial practice.
Some preliminary values and ranges of values for various types of evaporators are given in Table 8.3-1.

Table 8.3-1. Typical Heat-Transfer Coeffi cients  for Various Evaporators [*]  (B3, B4, L1, P1)

  Overall U

Type of Evaporator W/m 2  · K btu/h · ft 2  · °F

Short-tube vertical, natural circulation 1100-2800 200-500


Horizontal-tube, natural circulation 1100-2800 200-500
Long-tube vertical, natural circulation 1100-4000 200-700

Long-tube vertical, forced circulation 2300-11 000 400-2000


Agitated film 680-2300 120-400

[*]
 Generally, nonviscous liquids have the higher coefficients and viscous liquids the lower coefficients in the ranges given.
                             
                                                 
                                             
                                               
     

8.4. CALCULATION METHODS FOR SINGLE­EFFECT
EVAPORATORS

8.4 A. He at and  M ate r ial Balance s for  Ev ap or ator s

The basic equation for solving for the capacity of a single-effect evaporator is Eq. (8.2-1), which can be
written as

Equation 8.4-1

where ΔTK (°F) is the difference in temperature between the condensing steam and the boiling liquid in
the evaporator. In order to solve Eq. (8.4-1) the value of q in W (btu/h) must be determined by making a
heat and material balance on the evaporator shown in Fig. 8.4-1. The feed to the evaporator is F kg/h
(lbm/h) having a solids content of xF mass fraction, temperature TF, and enthalpy hF J/kg (btu/lbm).
Coming out as a liquid is the concentrated liquid L kg/h (lbm/h) having a solids content of xL,
temperature T1, and enthalpy hL. The vapor V kg/h (lbm/h) is given off as pure solvent having a solids
content of y V = 0, temperature T1, and enthalpy HV. Saturated steam entering is S kg/h (lbm/h) and has
a temperature of Ts and enthalpy of HS. The condensed steam leaving of S kg/h is assumed usually to be
at Ts, the saturation temperature, with an enthalpy of hS. This means that the steam gives off only its
latent heat, λ, where

Equation 8.4-2

Figure 8.4-1. Heat and mass balance for single-effe ct evaporator.
Since the vapor V is in equilibrium with the liquid L, the temperatures of vapor and liquid are the same.
Also, the pressure P1 is the saturation vapor pressure of the liquid of composition xL at its boiling point
T1. (This assumes no boiling-point rise.)

For the material balance, since we are at steady state, the rate of mass in = rate of mass out. Then, for a
total balance,

Equation 8.4-3

For a balance on the solute (solids) alone,

Equation 8.4-4

For the heat balance, since the total heat entering = total heat leaving,

Equation 8.4-5

This assumes no heat lost by radiation or convection. Substituting into Eq. (8.4-5),

Equation 8.4-6

Substituting Eq. (8.4-2) into (8.4-6),

Equation 8.4-7

The heat q transferred in the evaporator is then

Equation 8.4-8

In Eq. (8.4-7) the latent heat λ of steam at the saturation temperature Ts can be obtained from the steam
tables in Appendix A.2. However, the enthalpies of the feed and products are often not available; these
enthalpy-concentration data are available for only a few substances in solution. Hence, some
approximations are made in order to make a heat balance. These are as follows:

1.  It can be demonstrated as an approximation that the latent heat of evaporation of 1 kg mass of the
water from an aqueous solution can be obtained from the steam tables using the temperature of
the boiling solution T1 (exposed surface temperature) rather than the equilibrium temperature for
pure water at P1.

2.  If the heat capacities   of the liquid feed and   of the product are known, they can be used to


calculate the enthalpies. (This neglects heats of dilution, which in most cases are not known.)

EXAMPLE 8.4-1. Heat-Transfer Area in Single-Effect
Evaporator
A continuous single-effect evaporator concentrates 9072 kg/h of a 1.0 wt % salt solution
entering at 311.0 K (37.8°C) to a final concentration of 1.5 wt %. The vapor space of the
evaporator is at 101.325 kPa (1.0 atm abs) and the steam supplied is saturated at 143.3 kPa.
The overall coefficient U = 1704 W/m2 · K. Calculate the amounts of vapor and liquid product
and the heat-transfer area required. Assume that, since it is dilute, the solution has the same
boiling point as water.

S olu t ion: The flow diagram is the same as in Fig. 8.4-1. For the material balance,
substituting into Eq. (8.4-3),

Equation 8.4-3

Substituting into Eq. (8.4-4) and solving,

Equation 8.4-4

Substituting into Eq. (8.4-3) and solving,

The heat capacity of the feed is assumed to be   = 4.14 kJ/kg · K. (Often, for feeds of
inorganic salts in water, the cp can be assumed to be approximately that of water alone.) To
make a heat balance using Eq. (8.4-7), it is convenient to select the boiling point of the dilute
solution in the evaporator, which is assumed to be that of water at 101.32 kPa, T1 = 373.2 K
(100°C), as the datum temperature. Then HV is simply the latent heat of water at 373.2 K,
which from the steam tables in Appendix A.2 is 2257 kJ/kg (970.3 btu/lbm). The latent heat λ
of the steam at 143.3 kPa [saturation temperature TS = 383.2 K (230°F)] is 2230 kJ/kg (958.8
btu/lbm).

The enthalpy of the feed can be calculated from

Equation 8.4-9

Substituting into Eq. (8.4-7) with hL = 0, since it is at the datum of 373.2 K,

The heat q transferred through the heating surface area A is, from Eq. (8.4-8),

Equation 8.4-8

Substituting into Eq. (8.4-1), where ΔT = Ts – T1,

Solving, A = 149.3 m2.

8.4 B. Effe cts of Pr oce ssing Var iab le s on Ev ap or ator  Op e r ation

1. Effect  of feed  t emp er a t u r e

The inlet temperature of the feed has a large effect on the operation of the evaporator. In Example 8.4-1
the feed entering was at a temperature of 311.0 K, cold as compared to the boiling temperature of 373.2 K.

About   of the steam used for heating was used to heat the cold feed to the boiling point. Hence, only

about   of the steam was left for vaporization of the feed. If the feed is under pressure and enters the
evaporator at a temperature above the boiling point in the evaporator, additional vaporization is
obtained by flashing part of the entering hot feed. Preheating the feed can reduce the size of evaporator
heat-transfer area needed.

2. Effect  of p r essu r e

In Example 8.4-1 a pressure of 101.32 kPa abs was used in the vapor space of the evaporator. This set the
boiling point of the solution at 373.2 K and gave a ΔT for use in Eq. (8.4-1) of 383.2 – 373.2, or 10 K. In
many cases a larger ΔT is desirable, since, as ΔT increases, the heating-surface area A and cost of the
evaporator decrease. To reduce the pressure below 101.32 kPa, that is, to be under vacuum, a condenser
and vacuum pump can be used. For example, if the pressure were reduced to 41.4 kPa, the boiling point
of water would be 349.9 K and the new ΔT would be 383.2 – 349.9, or 33.3 K. A large decrease in heating-
surface area would be obtained.

3. Effect  of st ea m p r essu r e

Using higher-pressure, saturated steam increases ΔT, which decreases the size and cost of the
evaporator. However, high-pressure steam is more costly as well as often being more valuable as a source
of power elsewhere. Hence, overall economic balances are really needed to determine the optimum steam
pressures.

8.4 C . Boiling-Point R ise  of S olu tions

In the majority of cases in evaporation, the solutions are not dilute solutions such as those considered in
Example 8.4-1. In most cases, the thermal properties of the solution being evaporated may differ
considerably from those of water. The concentrations of the solutions are high enough that the heat
capacity and boiling point are quite different from those for water.

For strong solutions of dissolved solutes the boiling-point rise due to the solutes in the solution usually
cannot be predicted. However, a useful empirical law known as Dühring's rule can be applied. According
to this rule, a straight line is obtained if the boiling point of a solution in °C or °F is plotted against the
boiling point of pure water at the same pressure for a given concentration at different pressures. A
different straight line is obtained for each given concentration. In Fig. 8.4-2 such a Dühring-line chart is
given for solutions of sodium hydroxide in water. It is necessary to know the boiling point of a given
solution at only two pressures to determine a line.

Figure 8.4-2. Dühring lines for aqueous solutions of sodium hydroxide.
EXAMPLE 8.4-2. Use of Dühring Chart for Boiling-Point
Rise
As an example of use of the chart, the pressure in an evaporator is given as 25.6 kPa (3.72 psia)
and a solution of 30% NaOH is being boiled. Determine the boiling temperature of the NaOH
solution and the boiling-point rise BPR of the solution over that of water at the same pressure.

S olu t ion: From the steam tables in Appendix A.2, the boiling point of water at 25.6 kPa is
65.6°C. From Fig. 8.4-2 for 65.6°C (150°F) and 30% NaOH, the boiling point of the NaOH
solution is 79.5°C (175°F). The boiling-point rise is 79.5 – 65.6 = 13.9°C (25°F).

In Perry and Green (P1) a chart is given for estimating the boiling-point rise of a large number of common
aqueous solutions used in chemical and biological processes. In addition to the common salts and
solutes, such as NaNO3, NaOH, NaCl, and H2SO4, the biological solutes sucrose, citric acid, kraft
solution, and glycerol are given. These biological solutes have quite small boiling-point-rise values
compared to those of common salts.

8.4 D. Enthalp y-C once ntr ation C har ts of S olu tions

If the heat of solution of the aqueous solution being concentrated in the evaporator is large, neglecting it
could cause errors in the heat balances. This heat-of-solution phenomenon can be explained as follows. If
pellets of NaOH are dissolved in a given amount of water, it is found that a considerable temperature rise
occurs; that is, heat is evolved, called heat of solution. The amount of heat evolved depends on the type
of substance and the amount of water used. Also, if a strong solution of NaOH is diluted to a lower
concentration, heat is liberated. Conversely, if a solution is concentrated from a low to a high
concentration, heat must be added.

In Fig. 8.4-3 an enthalpy-concentration chart for NaOH is given (M1), where the enthalpy is in kJ/kg
(btu/lbm) solution, temperature in °C (°F), and concentration in weight fraction NaOH in solution. Such
enthalpy-concentration charts are usually not made for solutions having negligible heats of solution,
since the heat capacities can be easily used to calculate enthalpies. Also, such charts are available for
only a few solutions.

Figure 8.4-3. Enthalpy-concentration chart for the system NaOH-water. [Reference state liquid water at 0°C
(273 K) or 32°F.] [From W. L. McCabe, Trans. A.I.Ch.E., 31, 129 (1935). With permission.]

The enthalpy of the liquid water in Fig. 8.4-3 is referred to the same datum or reference state as in the
steam tables, that is, liquid water at 0°C (273 K). This means that enthalpies from the figure can be used
with those in the steam tables. In Eq. (8.4-7) values for hF and hL can be taken from Fig. 8.4-3 and values
for λ and HV from the steam tables. The uses of Fig. 8.4-3 will be better understood from the following
example.

EXAMPLE 8.4-3. Evaporation of an NaOH Solution
An evaporator is used to concentrate 4536 kg/h (10 000 lbm/h) of a 20% solution of NaOH in
water entering at 60°C (140°F) to a product of 50% solids. The pressure of the saturated steam
used is 172.4 kPa (25 psia) and the pressure in the vapor space of the evaporator is 11.7 kPa
(1.7 psia). The overall heat-transfer coefficient is 1560 W/m2 · K (275 btu/h · ft 2 · °F). Calculate
the steam used, the steam economy in kg vaporized/kg steam used, and the heating surface
area in m2.

S olu t ion: The process flow diagram and nomenclature are the same as in Fig. 8.4-1. The
given variables are F = 4536 kg/h, xF = 0.20 wt fraction, TF = 60°C, P1 = 11.7 kPa, steam
pressure = 172.4 kPa, and xL = 0.50 wt fraction. For the overall material balance, substituting
into Eq. (8.4-3),

Equation 8.4-3

Substituting into Eq. (8.4-4) and solving (8.4-3) and (8.4-4) simultaneously,

Equation 8.4-4

To determine the boiling point T1 of the 50% concentrated solution, we first obtain the boiling
point of pure water at 11.7 kPa from the steam tables, Appendix A.2, as 48.9°C (120°F). From
the Dühring chart, Fig. 8.4-2, for a boiling point of water of 48.9°C and 50% NaOH, the
boiling point of the solution is T1 = 89.5°C (193°F). Hence,

From the enthalpy–concentration chart (Fig. 8.4-3), for 20% NaOH at 60°C (140°F), hf = 214
kJ/kg (92 btu/lbm). For 50% NaOH at 89.5°C (193°F), hL = 505 kJ/kg (217 btu/lbm).

For the superheated vapor V at 89.5°C (193°F) and 11.7 kPa [superheated 40.6°C (73°F) since
the boiling point of water is 48.9°C (120°F) at 11.7 kPa], from the steam tables, HV = 2667
kJ/kg (1147 btu/lbm). An alternative method for calculating the HV is first to obtain the
enthalpy of saturated vapor at 48.9°C (120°F) and 11.7 kPa of 2590 kJ/kg (1113.5 btu/lbm).
Then, using a heat capacity of 1.884 kJ/kg · K for superheated steam with the superheat of
(89.5 – 48.9)°C = (89.5 – 48.9) K,

For the saturated steam at 172.4 kPa, the saturation temperature from the steam tables is
115.6°C (240°F) and the latent heat is λ = 2214 kJ/kg (952 btu/lbm).

Substituting into Eq. (8.4-7) and solving for S,

Equation 8.4-7
Substituting into Eq. (8.4-8),

Substituting into Eq. (8.4-1) and solving,

Hence, A = 49.2 m2. Also, steam economy = 2722/3255 = 0.836.
                             
                                                 
                                             
                                               
     

8.5. CALCULATION METHODS FOR MULTIPLE­EFFECT
EVAPORATORS

8.5A. Intr od u ction

In evaporation of solutions in a single-effect evaporator, a major cost is the cost of the steam used to
evaporate the water. A single-effect evaporator is wasteful in terms of steam costs, since the latent heat of
the vapor leaving the evaporator is usually not used. To reduce this cost, multiple-effect evaporators are
used, which recover the latent heat of the vapor leaving and reuse it.

A three-effect evaporator, discussed briefly in Section 8.2B, is shown in Fig. 8.2-3. In this system each
effect in itself acts as a single-effect evaporator. Raw steam is used as the heating medium to the first
effect, which is boiling at temperature T1 and pressure P1. The vapor removed from the first effect is then
used as the heating medium, condensing in the second effect and vaporizing water at temperature T2 and
pressure P2 in this effect. To transfer heat from the condensing vapor to the boiling liquid in this second
effect, the boiling temperature T2 must be less than the condensing temperature. This means that the
pressure P2 in the second effect is lower than P1 in the first effect. In a similar manner, vapor from the
second effect is condensed in heating the third effect. Hence, pressure P3 is less than P2. If the first effect
is operating at 1 atm abs pressure, the second and third effects will be under vacuum.

In the first effect, raw, dilute feed is added and is partly concentrated. Then this partly concentrated
liquid (Fig. 8.2-3) flows to the second evaporator in series, where it is further concentrated. This liquid
from the second effect flows to the third effect for final concentration.

When a multiple-effect evaporator is at steady-state operation, the flow rates and rate of evaporation in
each effect are constant. The pressures, temperatures, and internal flow rates are automatically kept
constant by the steady-state operation of the process itself. To change the concentration in the final
effect, the feed rate to the first effect must be changed. The overall material balance made over the whole
system and over each evaporator itself must be satisfied. If the final solution is too concentrated, the feed
rate must be increased, and vice versa. Then the final solution will reach a new steady state at the desired
concentration.

8.5B. Te m p e r atu r e  Dr op s and  C ap acity of M u ltip le -Effe ct Ev ap or ator s

1. Temp er a t u r e d r op s in mu lt ip le-effect  ev a p or a t or s

The amount of heat transferred per hour in the first effect of a triple-effect evaporator with forward feed as
in Fig. 8.2-3 will be

Equation 8.5-1
where ΔT1 is the difference between the condensing steam and the boiling point of the liquid, Ts – T1.
Assuming that the solutions have no boiling-point rise and no heat of solution and neglecting the
sensible heat necessary to heat the feed to the boiling point, approximately all the latent heat of the
condensing steam appears as latent heat in the vapor. This vapor then condenses in the second effect,
giving up approximately the same amount of heat:

Equation 8.5-2

This same reasoning holds for q3. Since q1 = q2 = q3, then, approximately,

Equation 8.5-3

In commercial practice the areas in all effects are usually equal and

Equation 8.5-4

Hence, the temperature drops ΔT in a multiple-effect evaporator are approximately inversely
proportional to the values of U. Calling ∑ ΔT as follows for no boiling-point rise,

Equation 8.5-5

Note that ΔT1 °C = ΔT1 K, ΔT2 °C = ΔT2 K, and so on. Since ΔT1 is proportional to 1/U1, then

Equation 8.5-6

Similar equations can be written for ΔT2 and ΔT3.

2. C a p a cit y  of mu lt ip le-effect  ev a p or a t or s

A rough estimate of the capacity of a three-effect evaporator compared to a single-effect can be obtained
by adding the value of q for each evaporator:

Equation 8.5-7
If we make the assumptions that the value of U is the same in each effect and that the values of A are
equal, Eq. (8.5-7) becomes

Equation 8.5-8

where ΔT = ∑ ΔT = ΔT1 + ΔT2 + ΔT3 = TS – T3.

If a single-effect evaporator is used with the same area A, the same value of U, and the same total
temperature drop ΔT, then

Equation 8.5-9

This, of course, gives the same capacity as for the multiple-effect evaporator. Hence, the increase in
steam economy obtained by using multiple-effect evaporators is obtained at the expense of reduced
capacity.

8.5C . C alcu lations for  M u ltip le -Effe ct Ev ap or ator s

In doing calculations for a multiple-effect evaporator system, the values to be obtained are usually the
area of the heating surface in each effect, the kg of steam per hour to be supplied, and the amount of
vapor leaving each effect, especially the last one. The given or known values are usually as follows: (1)
steam pressure to the first effect, (2) final pressure in the vapor space of the last effect, (3) feed conditions
and flow to the first effect, (4) the final concentration in the liquid leaving the last effect, (5) physical
properties such as enthalpies and/or heat capacities of the liquid and vapors, and (6) overall heat-
transfer coefficients in each effect. Usually, the areas of each effect are assumed equal.

The calculations are done using material balances, heat balances, and the capacity equations q = UA ΔT
for each effect. A convenient way to solve these equations is by trial and error. The basic steps to follow
are given as follows for a triple-effect evaporator.

8.5D. S te p -b y-S te p  C alcu lation M e thod s for  Tr ip le -Effe ct Ev ap or ator s

1. From the known outlet concentration and pressure in the last effect, determine the boiling point in
the last effect. (If a boiling-point rise is present, this can be determined from a Dühring-line plot.)

2. Determine the total amount of vapor evaporated by performing an overall material balance. For this
first trial, apportion the total amount of vapor among the three effects. (Usually, equal amounts of
vapor are produced in each effect, so that V1 = V2 = V3 is assumed for the first trial.) Make a total
material balance on effects 1, 2, and 3 to obtain L1, L2, and L3. Then calculate the solids
concentration in each effect by a solids balance on each effect.
3. Using Eq. (8.5-6), estimate the temperature drops ΔT1, ΔT2, and ΔT3 in the three effects. Any effect
that has an extra heating load, such as a cold feed, requires a proportionately larger ΔT. Then
calculate the boiling point in each effect.

[If a boiling-point rise (BPR) in °C is present, estimate the pressure in effects 1 and 2 and determine
the BPR in each of the three effects. Only a crude pressure estimate is needed, since BPR is almost
independent of pressure. Then the ∑ ΔT available for heat transfer without the superheat is obtained
by subtracting the sum of all three BPRs from the overall ΔT of TS – T3 (saturation). Using Eq. (8.5-
6), estimate ΔT1, ΔT2, and ΔT3. Then calculate the boiling point in each effect.]

4 . Using heat and material balances in each effect, calculate the amount vaporized and the flows of
liquid in each effect. If the amounts vaporized differ appreciably from those assumed in step 2, then
steps 2, 3, and 4 can be repeated using the amounts of evaporation just calculated. (In step 2 only
the solids balance is repeated.)

5. Calculate the value of q transferred in each effect. Using the rate equation q = UA ΔT for each effect,
calculate the areas A1, A2, and A3. Then calculate the average value Am by

Equation 8.5-10

If these areas are reasonably close to each other, the calculations are complete and a second trial is
not needed. If these areas are not almost equal, a second trial should be performed as follows.

6 . To start trial 2, use the new values of L1, L2, L3, V1, V2, and V3 calculated by the heat balances in step
4 and calculate the new solids concentration in each effect by a solids balance on each effect.

7.

Obtain new values  ,  , and   from

Equation 8.5-11

The sum   +   +   must equal the original ∑ ΔT. If not, proportionately readjust all ΔT'


values so that this is so. Then calculate the boiling point in each effect.

[If a boiling-point rise is present, determine the new BPRs in the three effects using the new
concentrations from step 6. To get a new value of ∑ ΔT available for heat transfer, subtract the sum of
all three BPRs from the overall ΔT. Calculate the new values of ΔT' by Eq. (8.5-11). The sum of the
ΔT' values just calculated must be readjusted to the new ∑ ΔT value. Then calculate the boiling point
in each effect.] Step 7 is essentially a repeat of step 3 but using Eq. (8.5-11) to obtain a better estimate
of the ΔT' values.

8. Using the new ΔT' values from step 7, repeat the calculations starting with step 4. Two trials are
usually sufficient so that the areas are reasonably close to being equal.

EXAMPLE 8.5-1. Evaporation of Sugar Solution in a Triple-
Effect Evaporator
A triple-effect forward-feed evaporator is being used to evaporate a sugar solution containing
10 wt % solids to a concentrated solution of 50%. The boiling-point rise of the solutions
(independent of pressure) can be estimated from BPR°C = 1.78x + 6.22x2 (BPR°F = 3.2x +
11.2x2), where x is wt fraction of sugar in solution (K1). Saturated steam at 205.5 kPa (29.8
psia) [121.1°C (250°F) saturation temperature] is being used. The pressure in the vapor space
of the third effect is 13.4 kPa (1.94 psia). The feed rate is 22 680 kg/h (50 000 lbm/h) at 26.7°C
(80°F). The heat capacity of the liquid solutions is (K1) cp = 4.19 – 2.35x kJ/kg · K (1.0 –
0.56x btu/lbm · °F). The heat of solution is considered to be negligible. The coefficients of heat

transfer have been estimated as U1 = 3123, U2 = 1987, and U3 = 1136 W/m2 · K, or 550, 350,

and 200 btu/h · ft 2 · °F. If each effect has the same surface area, calculate the area, the steam
rate used, and the steam economy.

S olu t ion: The process flow diagram is given in Fig. 8.5-1. Following the eight steps outlined,
the calculations are as follows:

S te p  1. For 13.4 kPa (1.94 psia), the saturation temperature is 51.67°C (125°F) from the
steam tables. Using the equation for BPR for evaporator number 3 with x = 0.5,

S te p  2. Making an overall and a solids balance to calculate the total amount vaporized (V1 +
V2 + V3) and L3,
Assuming equal amount vaporized in each effect, V1 = V2 = V3 = 6048 kg/h (13 333
lbm/h). Making a total material balance on effects 1, 2, and 3 and solving,

(1) F = 22 680 = V1  + L1  = 6048 + L1 , L1  = 16 632 kg/h (33 667 lbm/h)

(2) L1  = 16 632 = V2  + L2  = 6048 + L2 , L2  = 10 584 (23 334)

(3) L2  = 10 584 = V3  + L3  = 6048 + L3 , L3  = 4536(10 000)

Making a solids balance on effects 1, 2, and 3 and solving for x,

(1) 22 680(0.1) = L 1 x1 = 16 632(x1 ), x1  = 0.136  

(2) 16 632(0.136) = L 2 x2 = 10 584(x2 ), x2  = 0.214  

(3) 10 584(0.214) = L 3 x3 = 4536(x3 ), x3  = 0.500 (check balance)

S te p  3. The BPR in each effect is calculated as follows:

1.  BPR1 = 1.78x1 + 6.22  = 1.78(0.136) + 6.22(0.136)2 = 0.36°C (0.7°F)

2.  BPR2 = 1.78(0.214) + 6.22(0.214)2 = 0.65°C (1.2°F)

3.  BPR3 = 1.78(0.5) + 6.22(0.5)2 = 2.45°C (4.4°F)

Using Eq. (8.5-6) for ΔT1 and similar equations for ΔT2 and ΔT3,
However, since a cold feed enters effect number 1, this effect requires more heat.
Increasing ΔT1 and lowering ΔT2 and ΔT3 proportionately as a first estimate,

To calculate the actual boiling point of the solution in each effect,

(1) T1 = TS1  – ΔT1

    = 121.1 – 15.56 = 105.54°C

  TS1 = 121.1°C (condensing temperature of saturated steam to effect 1)

(2) T2 = T1  – BPR1  – ΔT2

    = 105.54 – 0.36 – 18.34 = 86.84°C

  Ts2 = T1  – BPR1  = 105.54 – 0.36

    = 105.18°C (condensing temperature of steam to effect 2)

(3) T3 = T2  – BPR2  – ΔT3

    = 86.84 – 0.65 – 32.07 = 54.12°C

  TS3 = T2  – BPR2

    = 86.84 – 0.65 = 86.19°C (condensing temperature of steam to effect 3)

The temperatures in the three effects are as follows:

S te p  4 . The heat capacity of the liquid in each effect is calculated from the equation cP = 4.19
– 2.35x:
The values of the enthalpy H of the various vapor streams relative to water at 0°C as
a datum are obtained from the steam table as follows:

Effect 1:

Effect 2:

Effect 3:

(Note that the superheat corrections in this example are small and could possibly
have been neglected. However, the corrections were used to demonstrate the method
of calculation.) Flow relations to be used in heat balances are

Write a heat balance on each effect. Using 0°C as a datum, since the values of H of
the vapors are relative to 0°C (32°F), and noting that (TF – 0)°C = (TF – 0) K and (T1
– 0)°C = (T1 – 0) K,

(1) Fcp (TF – 0) + SλS1  = L1 cp (T1  – 0) + V1 H1


Substituting the known values,

22 680(3.955)(26.7 – 0) + S(2200)

        = L1 (3.869)(105.54 – 0) + (22 680 – L1 )
(2685)
(2)   L1 cp (T1  – 0) + V1 λS2  = L2 cp (T2  – 0) + V2 H2

L1 (3.869)(105.54 – 0) + (22 680 – L1 )(2244)

  = L2 (3.684)(86.84 – 0) + (L1  – L2 )(2655)

(3) L2 cp (T2  – 0) + V2 λS3  = L3 cp (T3  – 0) + V3 H3

L2 (3.684)(86.84 – 0) + (L1  – L2 )(2294)

      = 4536(3.015)(54.12 – 0) + (L2  – 4536)(2600)

Solving the last two equations simultaneously for L1 and L2 and substituting into
the first equation,

The calculated values of V1, V2, and V3 are close enough to the assumed values that
steps 2, 3, and 4 do not need to be repeated. If the calculation were repeated, the
calculated values of V1, V2, and V3 would be used starting with step 2 and a solids
balance in each effect would be made.

S te p  5. Solving for the values of q in each effect and area,
The average area Am = 104.4 m2. The areas differ from the average value by less than
10% and a second trial is not really necessary. However, a second trial will be made
starting with step 6 to demonstrate the calculation methods used.

S te p  6 . Making a new solids balance on effects 1, 2, and 3, using the new L1 = 17 078, L2 = 11
068, and L3 = 4536, and solving for x,

(1) 22 680(0.1) = 17 078(x1 ), x1  = 0.133  

(2) 17 078(0.133) = 11 068(x2 ), x2  = 0.205  

(3) 11 068(0.205) = 4536(x3 ), x3  = 0.500 (check balance)

S te p  7. The new BPR in each effect is then

1.  BPR1 = 1.78x1 + 6.22  = 1.78(0.133) + 6.22(0.133)2 = 0.35°C

2.  BPR2 = 1.78(0.205) + 6.22(0.205)2 = 0.63°C

3.  BPR3 = 1.78(0.5) + 6.22(0.5)2 = 2.45°C

The new values for ΔT are obtained using Eq. (8.5-11):
These ΔT' values are readjusted so that   = 16.77,   = 16.87,   = 32.36,
and ∑ ΔT = 16.77 + 16.87 + 32.36 = 66.00°C. To calculate the actual boiling point of
the solution in each effect,

(1) T1 =  –   = 121.1 – 16.77 = 104.33°C, TS1  = 121.1°C


TS1

(2) T2 =  – BPR  –   = 104.33 – 0.35 – 16.87 = 87.11°C


T1 1

  TS2 = T1  – BPR1  = 104.33 – 0.35 = 103.98°C

(3) T3 =  – BPR  –   = 87.11 – 0.63 – 32.36 = 54.12°C


T2 2

  TS3 = T2  – BPR2  = 87.11 – 0.63 = 86.48°C

S te p  8. Following step 4, the heat capacity of the liquid is cp = 4.19 – 2.35x:

The new values of the enthalpy H are as follows in each effect:

(1) H1 = HS2  + 1.884(°C superheat) = 2682 + 1.884(0.35) = 2683 kJ/kg

  λS1 = HS1  – hs1  = 2708 – 508 = 2200 kJ/kg

(2) H2 = HS3  + 1.884(0.63) = 2654 + 1.884(0.63) = 2655 kJ/kg

  =
λs2 H1  – hS2  = 2683 – 440 = 2243 kJ/kg

(3) H3 = HS4  + 1.884(2.45) = 2595 + 1.884(2.45) = 2600 kJ/kg

  λs3 = H2  – hS3  = 2655 – 362 = 2293 kJ/kg

Writing a heat balance on each effect,

(1) 22 680(3.955)(26.7 – 0) + S(2200)
      = L1 (3.877)(104.33 – 0) + (22 680 – L1 )(2683)

(2) L1 (3.877)(104.33 – 0) + (22 680 – L1 )(2243)

        = L2 (3.708)(87.11 – 0) + (L1
– L2 )(2655)

(3) L2 (3.708)(87.11 – 0) + (L1  – L2 )(2293)

    = 4536(3.015)(54.12 – 0) + (L2  – 4536)(2600)

Solving,

Note that these values from trial 2 differ very little from the trial 1 results. Following
step 5, and solving for q in each effect and A,

The average area to use in each effect is Am = 105.0 m2. Note that this value of 105.0

m2 is quite close to the average value of 104.4 m2 from the first trial.
Figure 8.5-1. Flow diagram for triple-effect evaporation for Example 8.5-1.
                             
                                                 
                                             
                                               
     

8.6. CONDENSERS FOR EVAPORATORS

8.6 A. Intr od u ction

In multiple-effect evaporators the vapors from the last effect are usually leaving under vacuum, that is,
at less than atmospheric pressure. These vapors must be condensed and discharged as a liquid at
atmospheric pressure. This is done by using cooling water to condense the vapors. The condenser can be
a surface condenser, where the vapor to be condensed and the cooling liquid are separated by a metal
wall, or a direct-contact condenser, where the vapor and cooling liquid are mixed directly.

8.6 B. S u r face  C ond e nse r s

Surface condensers are employed where actual mixing of the condensate with condenser cooling water is
not desired. In general, they are shell-and-tube condensers, with the vapor on the shell side and cooling
water in multipass flow on the tube side. Noncondensable gases such as air, CO2, N2, or another gas are
usually present in the vapor stream. They may have entered as dissolved gases in the liquid feed or occur
because of decomposition in the solutions. These noncondensable gases may be vented from any well-
cooled point in the condenser. If the vapor being condensed is below atmospheric pressure, the
condensed liquid leaving the surface condenser can be removed by pumping and the noncondensable
gases by using a vacuum pump. Surface condensers are much more expensive and use more cooling
water, so they are usually not used in cases where a direct-contact condenser is suitable.

8.6 C . Dir e ct-C ontact C ond e nse r s

In direct-contact condensers cooling water directly contacts and condenses the vapors. One of the most
common types of direct-contact condenser is the countercurrent barometric condenser shown in Fig. 8.6-
1. The vapor enters the condenser and is condensed by rising upward against a shower of cooling water
droplets. The condenser is located on top of a long discharge tailpipe. The condenser is high enough
above the discharge point in the tailpipe that the water column established in the pipe more than
compensates for the difference in pressure between the low absolute pressure in the condenser and the
atmosphere. The water can then discharge by gravity through a seal pot at the bottom. A height of about
10.4 m (34 ft) is used.

Figure 8.6-1. Schematic of barometr ic condenser.
The barometric condenser is inexpensive and economical of water consumption. It can maintain a
vacuum corresponding to a saturated vapor temperature within about 2.8 K (5°F) of the water
temperature leaving the condenser. For example, if the discharge water is at 316.5 K (110°F), the pressure
corresponding to 316.5 + 2.8 or 319.3 K is 10.1 kPa (1.47 psia).

The water consumption can be estimated by a simple heat balance for a barometric condenser. If the
vapor flow to the condenser is V kg/h at temperature TS and the water flow is W kg/h at an entering
temperature of T1 and a leaving temperature of T2, the derivation is as follows:

Equation 8.6-1

where HS is the enthalpy from the steam tables of the vapor at TS K and the pressure in the vapor stream.
Solving,

Equation 8.6-2

The noncondensable gases can be removed from the condenser by a vacuum pump, either a mechanical
pump or a steam-jet ejector. In the ejector high-pressure steam enters a nozzle at high speed and entrains
the noncondensable gases from the space under vacuum.

Another type of direct-contact condenser is the jet barometric condenser. High-velocity jets of water act
as both a vapor condenser and an entrainer of the noncondensables out of the tail pipe. Jet condensers
usually require more water than the more-common barometric condensers and are more difficult to
throttle at low vapor rates.
                             
                                                 
                                             
                                               
     

8.7. EVAPORATION OF BIOLOGICAL MATERIALS

8.7A. Intr od u ction and  Pr op e r tie s of Biological M ate r ials

The evaporation of many biological materials frequently differs from the evaporation of inorganic
materials such as NaCl and NaOH and organic materials such as ethanol and acetic acid. Biological
materials such as pharmaceuticals, milk, citrus juices, and vegetable extracts are usually quite heat-
sensitive and often contain fine particles of suspended matter in solution. In addition, because of
problems due to bacteria growth, the equipment must be designed for easy cleaning. Many biological
materials in solution exhibit only a small boiling-point rise when concentrated. This is because
suspended solids in a fine, dispersed form and dissolved solutes of large molecular weight contribute
little to this rise.

The amount of degradation of biological materials on evaporation is a function of the temperature and
length of time. To keep the temperature low, the evaporation must be done under vacuum, which reduces
the boiling point of the solution. To keep the time of contact low, the equipment must provide for a low
holdup time (contact time) for the material being evaporated. Typical types of equipment used and some
biological materials processed are listed below. Detailed descriptions of the equipment are given in
Section 8.2.

1.  Long-tube vertical evaporator: condensed milk

2.  Falling-film evaporator: fruit juices

3.  Agitated-film (wiped-film) evaporator: rubber latex, gelatin, antibiotics, fruit juices

4.  Heat-pump cycle evaporator: fruit juices, milk, pharmaceuticals

8.7B. Fr u it Ju ice s

In the evaporation of fruit juices, such as orange juice, problems arise that are quite different from those
associated with the evaporation of a typical salt such as NaCl. The fruit juices are heat-sensitive and the
viscosity increases greatly as concentration increases. Also, solid suspended matter in fruit juices has a
tendency to cling to the heating surface, thus causing overheating which leads to burning and spoilage of
the matter (B2).

To reduce this tendency to stick and to reduce residence time, high rates of circulation over the heat-
transfer surface are necessary. Since the material is heat-sensitive, low-temperature operation is also
necessary. Hence, a fruit juice concentration plant usually employs a single and not a multiple
evaporation unit. Vacuum is used to reduce the temperature of evaporation.

A typical fruit juice evaporation system using the heat-pump cycle is shown in the literature (P1, C1); it
employs low-temperature ammonia as the heating fluid. A frozen concentrated citrus juice process is
described by Charm (C1). The process uses a multistage falling-film evaporator. A major fault of
concentrated orange juice is a flat flavor due to the loss of volatile constituents during evaporation. To
overcome this, a portion of the fresh pulpy juice bypasses the evaporation cycle and is blended with the
evaporated concentrate.
8.7C . S u gar  S olu tions

Sugar (sucrose) is obtained primarily from sugarcane and sugar beets. Sugar tends to caramelize if kept
at high temperatures for long periods (B2). The general tendency is to use short-tube evaporators of the
natural circulation type. In the evaporation process for sugar solutions, a clear solution of sugar having a
concentration of 10-13° Brix (10-13 wt %) is evaporated to 40-60° Brix (K1, S1).

The feed is first preheated by exhaust steam and then typically enters a six-effect forward-feed evaporator
system. The first effect operates at a pressure in the vapor space of the evaporator of about 207 kPa (30
psia) [121.1°C (250°F) saturation temperature] and the last effect under vacuum at about 24 kPa (63.9°C
saturation). Examples of the relatively small boiling-point rise of sugar solutions and the heat capacity
are given in Example 8.5-1.

8.7D. Pap e r -Pu lp  W aste  Liq u or s

In the manufacture of paper pulp in the sulfate process, wood chips are digested or cooked and spent
black liquor is obtained after washing the pulp. This solution contains primarily sodium carbonate and
organic sulfide compounds. It is concentrated by evaporation in a six-effect system (K1, S1).
                             
                                                 
                                             
                                               
     

8.8. EVAPORATION USING VAPOR RECOMPRESSION

8.8A. Intr od u ction

In the single-effect evaporator, the vapor from the unit is generally condensed and discarded. In the
multiple-effect evaporator, the pressure in each succeeding effect is lowered so that the boiling point of
the liquid is also lowered in each effect. Hence, there is a temperature difference created for the vapor
from one effect to condense in the next effect and boil the liquid to form vapor.

In a single-effect vapor-recompression (sometimes called vapor-compression) evaporator, the vapor is
compressed so that its condensing or saturation temperature is increased. This compressed vapor is
returned back to the heater of steam chest and condenses so that vapor is formed in the evaporator (B5,
W1, Z1). In this manner the latent heat of the vapor is used and not discarded. The two types of vapor-
recompression units are the mechanical and the thermal type.

8.8B. M e chanical Vap or -R e com p r e ssion Ev ap or ator

In a mechanical vapor-recompression evaporator, a conventional single-effect evaporator similar to that
in Fig. 8.2-2 is used, as shown in Fig. 8.8-1. The cold feed is preheated by exchange with the hot outlet
liquid product and then flows to the unit. The vapor coming overhead does not go to a condenser but is
sent to a centrifugal or positive-displacement compressor driven by an electric motor or steam. This
compressed vapor or steam is sent back to the heat exchanger or steam chest. The compressed vapor
condenses at a temperature higher than the boiling point of the hot liquid in the effect, and a temperature
difference is set up. Vapor is again generated and the cycle repeated.

Figure 8.8-1. Simplified process flow for mechanical vapor recompression evaporator.

Sometimes it is necessary to add a small amount of makeup steam to the vapor line before the
compressor (B5, K2). Also, a small amount of condensate may be added to the compressed vapor to
remove any superheat, if present.

Vapor-recompression units generally operate at low optimum-temperature differences of 5-10°C. Hence,
large heat-transfer areas are needed. These units usually have higher capital costs than multiple-effect
units because of the larger area and the costs of the relatively expensive compressor and drive unit. The
main advantage of vapor-recompression units is their lower energy costs. Using the steam equivalent of
the power to drive the compressor, the steam economy is equivalent to a multiple-effect evaporator of up
to 10 or more units (Z1).

Some typical applications of mechanical vapor-recompression units are evaporation of seawater to give
distilled water, evaporation of kraft black liquor in the paper industry (L2), evaporation of heat-sensitive
materials such as fruit juices, and crystallization of salts having inverse solubility curves, where the
solubility decreases with increasing temperature (K2, M3).

Falling-film evaporators are well suited for vapor-recompression systems (W1) because they operate at
low-temperature-difference values and have very little entrained liquid which can cause problems in the
compressor. Vapor recompression has been used in distillation towers where the overhead vapor is
recompressed and used in the reboiler as the heating medium (M2).

8.8C . The r m al Vap or -R e com p r e ssion Ev ap or ator

A steam jet can also be used to compress the vapor, in what is called a thermal vapor-recompression
evaporator. Its main disadvantages are the low efficiency of the steam jet, necessitating the removal of
this excess heat, and the lack of flexibility to changes in process variables (M3). Steam jets are cheaper
and more durable than mechanical compressors and can more easily handle large volumes of low-
pressure vapors.
                             
                                                 
                                             
                                               
     

PROBLEMS
8.4 -1.
Hea t -Tr a nsfer  C oefficient  in S ing le-Effect  Ev a p or a t or . A feed of 4535 kg/h of a 2.0 wt %
salt solution at 311 K enters continuously a single-effect evaporator and is being concentrated to
3.0%. The evaporation is at atmospheric pressure and the area of the evaporator is 69.7 m2.
Saturated steam at 383.2 K is supplied for heating. Since the solution is dilute, it can be
assumed to have the same boiling point as water. The heat capacity of the feed can be taken as cp
= 4.10 kJ/kg · K. Calculate the amounts of vapor and liquid product and the overall heat-
transfer coefficient U.
A1: Ans.  U =  1823 W/m2 · K
8.4 -2.
Effect s of Incr ea sed  Feed  R a t e in Ev a p or a t or . Using the same area, value of U, steam
pressure, evaporator pressure, and feed temperature as in Problem 8.4-1, calculate the amounts
of liquid and vapor leaving and the liquid outlet concentration if the feed rate is increased to
6804 kg/h.
A2:Ans. V = 1256 kg/h, L = 5548 kg/h, xL = 2.45%
8.4 -3.
Effect  of Ev a p or a t or  Pr essu r e on C a p a cit y  a nd  Pr od u ct  C omp osit ion. Recalculate
Example 8.4-1 but use an evaporator pressure of 41.4 kPa instead of 101.32 kPa abs. Use the
same steam pressure, area A, and heat-transfer coefficient U in the calculations.

a.  Do this to obtain the new capacity or feed rate under these new conditions. The
composition of the liquid product will be the same as before.

b.  Do this to obtain the new product composition if the feed rate is increased to 18 144 kg/h.

8.4 -4 .
Pr od u ct ion of Dist illed  W a t er . An evaporator having an area of 83.6 m2 and U = 2270
W/m2 · K is used to produce distilled water for a boiler feed. Tap water having 400 ppm
dissolved solids at 15.6°C is fed to the evaporator operating at 1 atm pressure abs. Saturated
steam at 115.6°C is available for use. Calculate the amount of distilled water produced per hour
if the outlet liquid contains 800 ppm solids.
8.4 -5.
Boiling -Point  R ise of Na OH S olu t ions. Determine the boiling temperature of the solution
and the boiling-point rise for the following cases:

a.  A 30% NaOH solution boiling in an evaporator at a pressure of 172.4 kPa (25 psia).

b.  A 60% NaOH solution boiling in an evaporator at a pressure of 3.45 kPa (0.50 psia).

A5:Ans. (a) Boiling point = 130.6°C, boiling-point rise = 15°C
8.4 -6 .
Boiling -Point  R ise of Biolog ica l S olu t es in S olu t ion. Determine the boiling-point rise for
the following solutions of biological solutes in water. Use the figure in (P1), pp. 11-112.
a.  A 30 wt % solution of citric acid in water boiling at 220°F (104.4°C).

b.  A 40 wt % solution of sucrose in water boiling at 220°F (104.4°C).

A6 :Ans. (a) Boiling-point rise = 2.2°F (1.22°C)
8.4 -7.
Effect  of Feed  Temp er a t u r e on Ev a p or a t ing  a n Na OH S olu t ion. A single-effect
evaporator is concentrating a feed of 9072 kg/h of a 10 wt % solution of NaOH in water to a
product of 50% solids. The pressure of the saturated steam used is 42 kPa (gage) and the
pressure in the vapor space of the evaporator is 20 kPa (abs). The overall heat-transfer coefficient
is 1988 W/m2 · K. Calculate the steam used, the steam economy in kg vaporized/kg steam, and
the area for the following feed conditions:

a.  Feed temperature of 288.8 K (15.6°C).

b.  Feed temperature of 322.1 K (48.9°C).

A7: Ans.  (a) S =  8959 kg/h of steam, A =  296.9 m2


8.4 -8.
Hea t -Tr a nsfer  C oefficient  t o Ev a p or a t e Na OH. In order to concentrate 4536 kg/h of an
NaOH solution containing 10 wt % NaOH to a 20 wt % solution, a single-effect evaporator is
being used, with an area of 37.6 m2. The feed enters at 21.1°C (294.3 K). Saturated steam at
110°C (383.2 K) is used for heating and the pressure in the vapor space of the evaporator is 51.7
kPa. Calculate the kg/h of steam used and the overall heat-transfer coefficient.
8.4 -9 .
Thr ou g hp u t  of a  S ing le-Effect  Ev a p or a t or . An evaporator is concentrating F kg/h at 311 K
of a 20 wt % solution of NaOH to 50%. The saturated steam used for heating is at 399.3 K. The
pressure in the vapor space of the evaporator is 13.3 kPa abs. The overall coefficient is 1420
W/m2 · K and the area is 86.4 m2. Calculate the feed rate F of the evaporator.
A9 :Ans. F = 9072 kg/h
8.4 -10.
S u r fa ce Ar ea  a nd  S t ea m C onsu mp t ion of a n Ev a p or a t or . A single-effect evaporator is
concentrating a feed solution of organic colloids from 5 to 50 wt %. The solution has a negligible
boiling-point elevation. The heat capacity of the feed is cp = 4.06 kJ/kg · K (0.97 btu/lbm · °F)
and the feed enters at 15.6°C (60°F). Saturated steam at 101.32 kPa is available for heating, and
the pressure in the vapor space of the evaporator is 15.3 kPa. A total of 4536 kg/h (10 000 lbm/h)

of water is to be evaporated. The overall heat-transfer coefficient is 1988 W/m2 · K (350 btu/h ·
°F). What is the required surface area in m2 and the steam consumption?

8.4 -11.
Ev a p or a t ion of Toma t o Ju ice Und er  Va cu u m. Tomato juice having a concentration of 12
wt % solids is being concentrated to 25% solids in a film-type evaporator. The maximum
allowable temperature for the tomato juice is 135°F, which will be the temperature of the
product. The feed enters at 100°F. Saturated steam at 25 psia is used for heating. The overall
heat-transfer coefficient U is 600 btu/h · ft 2 · °F and the area A is 50 ft 2. The heat capacity of the
feed cp is estimated as 0.95 btu/lbm · °F Neglect any boiling-point rise if present. Calculate the
feed rate of tomato juice to the evaporator.
8.4 -12.
C oncent r a t ion of C a ne S u g a r  S olu t ion. A single-effect evaporator is being used to
concentrate a feed of 10 000 lbm/h of a cane sugar solution at 80°F and containing a sugar
content of 15° Brix (degrees Brix is wt % sugar) to 30° Brix for use in a food process. Saturated
steam at 240°F is available for heating. The vapor space in the evaporator will be at 1 atm abs
pressure. The overall U = 350 btu/h · ft 2 · °F and the heat capacity of the feed is cp = 0.91
btu/lbm · °F The boiling-point rise can be estimated from Example 8.5-1. The heat of solution
can be considered negligible and neglected. Calculate the area required for the evaporator and
the amount of steam used per hour.
A12: Ans.  Boiling-point rise = 2.0°F (1.1°C), A = 667 ft 2 (62.0 m2)
8.5-1.
Boiling  Point s in a  Tr ip le-Effect  Ev a p or a t or . A solution with a negligible boiling-point
rise is being evaporated in a triple-effect evaporator using saturated steam at 121.1°C (394.3 K).
The pressure in the vapor of the last effect is 25.6 kPa abs. The heat-transfer coefficients are U1 =

2840, U2 = 1988, and U3 = 1420 W/m2 · K, and the areas are equal. Estimate the boiling point
in each of the evaporators.
A13:Ans. T1 = 108.6°C (381.8 K)
8.5-2.
Ev a p or a t ion of S u g a r  S olu t ion in a  M u lt ip le-Effect  Ev a p or a t or . A triple-effect
evaporator with forward feed is evaporating a sugar solution with negligible boiling-point rise
(less than 1.0 K, which will be neglected) and containing 5 wt % solids to 25% solids. Saturated
steam at 205 kPa abs is being used. The pressure in the vapor space of the third effect is 13.65
kPa. The feed rate is 22 680 kg/h and the temperature 299.9 K. The liquid heat capacity is cp =
4.19 – 2.35 x, where cp is in kJ/kg · K and x in wt fraction (K1). The heat-transfer coefficients are

U1 = 3123, U2 = 1987, and U3 = 1136 W/m2 · K. Calculate the surface area of each effect if each
effect has the same area, and the steam rate.
A14 : Ans.  Area A =  99.1 m2, steam rate S =  8972 kg/h
8.5-3.
Ev a p or a t ion in Dou b le-Effect  R ev er se-Feed  Ev a p or a t or s. A feed containing 2 wt %
dissolved organic solids in water is fed to a double-effect evaporator with reverse feed. The feed
enters at 100°F and is concentrated to 25% solids. The boiling-point rise can be considered
negligible, as can the heat of solution. Each evaporator has a 1000-ft 2 surface area, and the heat-
transfer coefficients are U1 = 500 and U2 = 700 btu/h · ft 2 · °F. The feed enters evaporator
number 2 and steam at 100 psia is fed to number 1. The pressure in the vapor space of evaporator
number 2 is 0.98 psia. Assume that the heat capacity of all liquid solutions is that of liquid
water. Calculate the feed rate F and the product rate L1 of a solution containing 25% solids.
(Hint: Assume a feed rate of, say, F = 1000 lbm/h and a value of T1. Calculate the area and T1.
Then calculate the actual feed rate by multiplying 1000 by 1000/calculated area.)
A15:Ans. F = 133 800 lbm/h (60 691 kg/h), L1 = 10 700 lbm/h (4853 kg/h)
8.5-4 .
C oncent r a t ion of Na OH S olu t ion in Tr ip le-Effect  Ev a p or a t or . A forced-circulation
triple-effect evaporator using forward feed is to be used to concentrate a 10 wt % NaOH solution
entering at 37.8°C to 50%. The steam used enters at 58.6 kPa gage. The absolute pressure in the
vapor space of the third effect is 6.76 kPa. The feed rate is 13 608 kg/h. The heat-transfer
coefficients are U1 = 6246, U2 = 3407, and U3 = 2271 W/m2 · K. All effects have the same area.
Calculate the surface area and steam consumption.
A16 : Ans.  A =  97.3 m2, S =  5284 kg steam/h
8.5-5.
Tr ip le-Effect  Ev a p or a t or  w it h R ev er se Feed . A feed rate of 20 410 kg/h of 10 wt % NaOH
solution at 48.9°C is being concentrated in a triple-effect reverse-feed evaporator to produce a
50% solution. Saturated steam at 178.3°C is fed to the first evaporator and the pressure in the
third effect is 10.34 kPa abs. The heat-transfer coefficient for each effect is assumed to be 2840
W/m2 · K. Calculate the heat-transfer area and the steam consumption rate.
8.5-6 .
Ev a p or a t ion of S u g a r  S olu t ion in Dou b le-Effect  Ev a p or a t or . A double-effect
evaporator with reverse feed is used to concentrate 4536 kg/h of a 10 wt % sugar solution to 50%.
The feed enters the second effect at 37.8°C. Saturated steam at 115.6°C enters the first effect and
the vapor from this effect is used to heat the second effect. The absolute pressure in the second
effect is 13.65 kPa abs. The overall coefficients are U1 = 2270 and U2 = 1705 W/m2 · K. The
heating areas for both effects are equal. Use boiling-point-rise and heat-capacity data from
Example 8.5-1. Calculate the area and steam consumption.
8.6 -1.
W a t er  C onsu mp t ion a nd  Pr essu r e in Ba r omet r ic C ond enser . The concentration of
NaOH solution leaving the third effect of a triple-effect evaporator is 50 wt %. The vapor flow
rate leaving is 5670 kg/h and this vapor goes to a barometric condenser. The discharge water
from the condenser leaves at 40.5°C. Assuming that the condenser can maintain a vacuum in
the third effect corresponding to a saturated vapor pressure of 2.78°C above 40.5°C, calculate
the pressure in the third effect and the cooling-water flow to the condenser. The cooling water
enters at 29.5°C. (Note: The vapor leaving the evaporator will be superheated because of the
boiling-point rise.)

A19 :Ans. Pressure = 8.80 kPa abs, W = 306 200 kg water/h
                             
                                                 
                                             
                                               
     

Chapter 9. Drying of Process Materials
                             
                                                 
                                             
                                               
     

9.1. INTRODUCTION AND METHODS OF DRYING

9 .1A. Pu r p ose s of Dr ying

The discussions of drying in this chapter are concerned with the removal of water from process materials
and other substances. The term “drying” is also used to refer to removal of other organic liquids, such as
benzene or organic solvents, from solids. Many of the types of equipment and calculation methods
discussed for removal of water can also be used for removal of organic liquids.

Drying generally means removal of relatively small amounts of water from material. Evaporation refers
to removal of relatively large amounts of water from material. In evaporation the water is removed as
vapor at its boiling point. In drying the water is usually removed as a vapor by air.

In some cases water may be removed mechanically from solid materials by means of presses,
centrifuging, and other methods. This is cheaper than drying by thermal means for removal of water,
which will be discussed here. The moisture content of the final dried product varies depending upon the
type of product. Dried salt contains about 0.5% water, coal about 4%, and many food products about 5%.
Drying is usually the final processing step before packaging and makes many materials, such as soap
powders and dyestuffs, more suitable for handling.

Drying or dehydration of biological materials, especially foods, is used as a preservation technique.
Microorganisms that cause food spoilage and decay cannot grow and multiply in the absence of water.
Also, many enzymes that cause chemical changes in food and other biological materials cannot function
without water. When the water content is reduced below about 10 wt %, the microorganisms are not
active. However, it is usually necessary to lower the moisture content below 5 wt % in foods to preserve
flavor and nutrition. Dried foods can be stored for extended periods of time.

Some biological materials and pharmaceuticals, which may not be heated for ordinary drying, may be
freeze-dried, as discussed in Section 9.11. Also, in Section 9.12, sterilization of foods and other biological
materials is discussed, which is another method often employed to preserve such materials.

9 .1B. G e ne r al M e thod s of Dr ying

Drying methods and processes can be classified in several different ways. Drying processes can be
classified as batch, where the material is inserted into the drying equipment and drying proceeds for a
given period of time, or as continuous, where the material is continuously added to the dryer and dried
material is continuously removed.

Drying processes can also be categorized according to the physical conditions used to add heat and
remove water vapor: (1) in the first category, heat is added by direct contact with heated air at
atmospheric pressure, and the water vapor formed is removed by the air; (2) in vacuum drying, the
evaporation of water proceeds more rapidly at low pressures, and the heat is added indirectly by contact
with a metal wall or by radiation (low temperatures can also be used under vacuum for certain materials
that may discolor or decompose at higher temperatures); and (3) in freeze-drying, water is sublimed from
the frozen material.
                             
                                                 
                                             
                                               
     

9.2. EQUIPMENT FOR DRYING

9 .2A. Tr ay Dr ye r

In tray dryers, which are also called shelf, cabinet, or compartment dryers, the material, which may be a
lumpy solid or a pasty solid, is spread uniformly on a metal tray to a depth of 10 to 100 mm. Such a
typical tray dryer, shown in Fig. 9.2-1, contains removable trays loaded in a cabinet.

Figure 9.2-1. Tray or shelf dryer.

Steam-heated air is recirculated by a fan over and parallel to the surface of the trays. Electrical heat is
also used, especially for low heating loads. About 10 to 20% of the air passing over the trays is fresh air,
the remainder being recirculated air.

After drying, the cabinet is opened and the trays are replaced with a new batch of trays. A modification of
this type is the tray–truck type, where trays are loaded on trucks which are pushed into the dryer. This
saves considerable time, since the trucks can be loaded and unloaded outside the dryer.

In the case of granular materials, the material can be loaded on screens which form the bottom of each
tray. Then, in this through-circulation dryer, heated air passes through the permeable bed, yielding
shorter drying times because of the greater surface area exposed to the air.

9 .2B. Vacu u m -S he lf Ind ir e ct Dr ye r s

Vacuum-shelf dryers are indirectly heated batch dryers similar to tray dryers. Such a dryer consists of a
cabinet made of cast-iron or steel plates with tightly fitted doors so that it can be operated under
vacuum. Hollow shelves of steel are fastened permanently inside the chamber and are connected in
parallel to inlet and outlet steam headers. The trays containing the solids to be dried rest upon the
hollow shelves. The heat is conducted through the metal walls and aided by radiation from the shelf
above. For low-temperature operation, circulating warm water is used instead of steam for furnishing the
heat to vaporize the moisture. The vapors usually pass to a condenser.

These dryers are used to dry expensive or temperature-sensitive or easily oxidizable materials. They are
useful for handling materials with toxic or valuable solvents.
9 .2C . C ontinu ou s Tu nne l Dr ye r s

Continuous tunnel dryers are often batch truck or tray compartments operated in series, as shown in Fig.
9.2-2a. The solids are placed on trays or on trucks which move continuously through a tunnel with hot
gases passing over the surface of each tray. The hot air flow can be countercurrent, cocurrent, or a
combination. Many foods are dried in this way.

Figure 9.2-2. Continuous tunnel dryers: (a) tunnel dryer trucks with countercurrent air flow, (b) through-
circulation screen conveyor dryer.

When granular particles of solids are to be dried, perforated or screen-belt continuous conveyors are often
used, as in Fig. 9.2-2b. The wet granular solids are conveyed as a layer 25 to about 150 mm deep on a
screen or perforated apron while heated air is blown upward through the bed or downward. The dryer
consists of several sections in series, each with a fan and heating coils. A portion of the air is exhausted to
the atmosphere by a fan. In some cases pasty materials can be preformed into cylinders and placed on
the bed to be dried.

9 .2D. R otar y Dr ye r s

A rotary dryer consists of a hollow cylinder which is rotated and usually slightly inclined toward the
outlet. The wet granular solids are fed at the high end as shown in Fig. 9.2-3 and move through the shell
as it rotates. The heating shown is by direct contact with hot gases in countercurrent flow. In some cases
the heating is by indirect contact through the heated wall of the cylinder.

Figure 9.2.3. Schematic drawing of a direct-heat rotary dryer.
The granular particles move forward slowly a short distance before they are showered downward through
the hot gases as shown. Many other variations of this rotary dryer are available; these are discussed
elsewhere (P1).

9 .2E. Dr u m  Dr ye r s

A drum dryer consists of a heated metal roll, shown in Fig. 9.2-4, on the outside of which a thin layer of
liquid or slurry is evaporated to dryness. The final dry solid is scraped off the roll, which is revolving
slowly.

Figure 9.2.4. Rotary-drum dryer.

Drum dryers are suitable for handling slurries or pastes of solids in fine suspension and for solutions. The
drum functions partly as an evaporator as well as a dryer. Other variations of the single-drum type are
twin rotating drums with dip feeding or with top feeding to the two drums. Potato slurry is dried using
drum dryers, to give potato flakes.

9 .2F. S p r ay Dr ye r s

In a spray dryer a liquid or slurry solution is sprayed into a hot gas stream in the form of a mist of fine
droplets. The water is rapidly vaporized from the droplets, leaving particles of dry solid which are
separated from the gas stream. The flow of gas and liquid in the spray chamber may be countercurrent,
cocurrent, or a combination.

The fine droplets are formed from the liquid feed by spray nozzles or high-speed rotating spray disks
inside a cylindrical chamber, as shown in Fig. 9.2-5. It is necessary to ensure that the droplets or wet
particles of solid do not strike and stick to solid surfaces before drying has taken place; hence, large
chambers are used. The dried solids leave at the bottom of the chamber through a screw conveyor. The
exhaust gases flow through a cyclone separator to remove any fines. The particles produced are usually
light and quite porous. Dried milk powder is made from spray-drying milk.

Figure 9.2-5. Process flow diagram of spray-drying apparatus.

9 .2G . Dr ying of C r op s and  G r ains

In the drying of grain from a harvest, the grain contains about 30 to 35% moisture, and for safe storage
for about 1 year should be dried to about 13 wt % moisture (H1). A typical continuous-flow dryer is shown
in Fig. 9.2-6. In the drying bin the thickness of the layer of grain, through which the hot air passes, is 0.5
m or less. Unheated air in the bottom section cools the dry grain before it leaves. Other types of crop
dryers and storage bins are described by Hall (H1).

Figure 9.2-6. Vertical continuous-flow grain dryer.
                             
                                                 
                                             
                                               
     

9.3. VAPOR PRESSURE OF WATER AND HUMIDITY

9 .3A. Vap or  Pr e ssu r e  of W ate r

1. Int r od u ct ion

In a number of the separation processes and transport processes, it is necessary to make calculations
involving the properties of mixtures of water vapor and air. These calculations involve knowledge of the
concentration of water vapor in air under various conditions of temperature and pressure, the thermal
properties of these mixtures, and the changes occurring when these mixtures are brought into contact
with water or with wet solids in drying.

Humidification involves the transfer of water from the liquid phase into a gaseous mixture of air and
water vapor. Dehumidification involves the reverse transfer, whereby water vapor is transferred from the
vapor state to the liquid state. Humidification and dehumidification can also refer to vapor mixtures of
materials such as benzene, but most practical applications occur with water. To better understand
humidity, it is first necessary to discuss the vapor pressure of water.

2. Va p or  p r essu r e of w a t er  a nd  p hy sica l st a t es

Pure water can exist in three different physical states: solid ice, liquid, and vapor. The physical state in
which it exists depends on the pressure and temperature.

Figure 9.3-1 illustrates the various physical states of water and the pressure–temperature relationships
at equilibrium. In Fig. 9.3-1 the regions of the solid, liquid, and vapor states are shown. Along the line
AB, the phases liquid and vapor coexist. Along line AC, the phases ice and liquid coexist. Along line AD,
ice and vapor coexist. If ice at point (1) is heated at constant pressure, the temperature rises and the
physical condition is represented as moving horizontally. As the horizontal line crosses AC, the solid
melts, and on crossing AB the liquid vaporizes. Moving from point (3) to (4), ice sublimes (vaporizes) to
a vapor without becoming a liquid.

Figure 9.3-1. Phase diagram for water.
Liquid and vapor coexist in equilibrium along the line AB, which is the vapor-pressure line for water.
Boiling occurs when the vapor pressure of the water is equal to the total pressure above the water surface.
For example, at 100°C (212°F) the vapor pressure of water is 101.3 kPa (1.0 atm), and therefore it will boil
at 1 atm pressure. At 65.6°C (150°F), from the steam tables in Appendix A.2, the vapor pressure of water
is 25.7 kPa (3.72 psia). Hence, at 25.7 kPa and 65.6°C, water will boil.

If a pan of water is held at 65.6°C in a room at 101.3 kPa abs pressure, the vapor pressure of water will
again be 25.7 kPa. This illustrates an important property of the vapor pressure of water, which is not
influenced by the presence of an inert gas such as air; that is, the vapor pressure of water is essentially
independent of the total pressure of the system.

9 .3B. Hu m id ity and  Hu m id ity C har t

1. Definit ion of hu mid it y

The humidity H of an air–water vapor mixture is defined as the kg of water vapor contained in 1 kg of dry
air. The humidity so defined depends only on the partial pressure pA of water vapor in the air and on the
total pressure P (assumed throughout this chapter to be 101.325 kPa, 1.0 atm abs, or 760 mm Hg). Using
the molecular weight of water (A) as 18.02 and of air as 28.97, the humidity H in kg H2O/kg dry air, or in
English units as lb H2O/lb dry air, is as follows:

Equation 9.3-1

Saturated air is air in which the water vapor is in equilibrium with liquid water at the given conditions of
pressure and temperature. In this mixture the partial pressure of the water vapor in the air–water
mixture is equal to the vapor pressure pAS of pure water at the given temperature. Hence, the saturation
humidity HS is

Equation 9.3-2

2. Per cent a g e hu mid it y

The percentage humidity HP is defined as 100 times the actual humidity H of the air divided by the
humidity HS if the air were saturated at the same temperature and pressure:

Equation 9.3-3
3. Per cent a g e r ela t iv e hu mid it y

The amount of saturation of an air–water vapor mixture is also given as percentage relative humidity HR
using partial pressures:

Equation 9.3-4

Note that HR ≠ HP, since HP expressed in partial pressures by combining Eqs. (9.3-1), (9.3-2), and (9.3-
3) is

Equation 9.3-5

This, of course, is not the same as Eq. (9.3-4).

EXAMPLE 9.3-1. Humidity from Vapor-Pressure Data
The air in a room is at 26.7°C (80°F) and a pressure of 101.325 kPa and contains water vapor
with a partial pressure pA = 2.76 kPa. Calculate the following:

a.  Humidity, H.

b.  Saturation humidity, HS, and percentage humidity, HP.

c.  Percentage relative humidity, HR.

S olu t ion: From the steam tables at 26.7°C, the vapor pressure of water is pAS = 3.50 kPa
(0.507 psia). Also, pA = 2.76 kPa and P = 101.3 kPa (14.7 psia). For part (a), using Eq. (9.3-1),

For part (b), using Eq. (9.3-2), the saturation humidity is
The percentage humidity, from Eq. (9.3-3), is

For part (c), from Eq. (9.3-4), the percentage relative humidity is

4 . Dew  p oint  of a n a ir –w a t er  v a p or  mixt u r e

The temperature at which a given mixture of air and water vapor would be saturated is called the dew-
point temperature or simply the dew point. For example, at 26.7°C (80°F), the saturation vapor
pressure of water is pAS = 3.50 kPa (0.507 psia). Hence, the dew point of a mixture containing water
vapor having a partial pressure of 3.50 kPa is 26.7°C. If an air–water vapor mixture is at 37.8°C (often
called the dry bulb temperature, since this is the actual temperature a dry thermometer bulb would
indicate in this mixture) and contains water vapor of pA = 3.50 kPa, the mixture would not be saturated.
On cooling to 26.7°C, the air would be saturated, that is, at the dew point. On further cooling, some
water vapor would condense, since the partial pressure cannot be greater than the saturation vapor
pressure.

5. Hu mid  hea t  of a n a ir –w a t er  v a p or  mixt u r e

The humid heat cs is the amount of heat in J (or kJ) required to raise the temperature of 1 kg of dry air
plus the water vapor present by 1 K or 1°C. The heat capacity of air and water vapor can be assumed
constant over the temperature ranges usually encountered at 1.005 kJ/kg dry air · K and 1.88 kJ/kg
water vapor · K, respectively. Hence, for SI and English units,

Equation 9.3-6

[In some cases cS will be given as (1.005 + 1.88H)103 J/kg · K.]

6 . Hu mid  v olu me of a n a ir –w a t er  v a p or  mixt u r e

The humid volume νH is the total volume in m3 of 1 kg of dry air plus the vapor it contains at 101.325 kPa
(1.0 atm) abs pressure and the given gas temperature. Using the ideal gas law,

Equation 9.3-7

For a saturated air–water vapor mixture, H = HS, and νH is the saturated volume.

7. Tot a l ent ha lp y  of a n a ir –w a t er  v a p or  mixt u r e

The total enthalpy of 1 kg of air plus its water vapor is Hy  J/kg or kJ/kg dry air. If T0 is the datum
temperature chosen for both components, the total enthalpy is the sensible heat of the air–water vapor
mixture plus the latent heat λ 0 in J/kg or kJ/kg water vapor of the water vapor at T0. Note that (T −
T0)°C = (T − T0) K and that this enthalpy is referred to liquid water.

Equation 9.3-8

If the total enthalpy is referred to a base temperature T0 of 0°C (32°F), the equation for Hy  becomes

Equation 9.3-9

8. Hu mid it y  cha r t  of a ir –w a t er  v a p or  mixt u r es

A convenient chart of the properties of air–water vapor mixtures at 1.0 atm abs pressure is the humidity
chart in Fig. 9.3-2. In this figure the humidity H is plotted versus the actual temperature of the air–water
vapor mixture (dry bulb temperature).

Figure 9.3-2. Humidity chart for mixtures of air and water vapor at a total pressure of 101.325 kPa (760 mm
Hg). (From R. E. Treybal, Mass-Transfer Operations, 3rd ed. New York: McGraw-Hill Book Company, 1980.
With permission.)
The curve marked 100% running upward to the right gives the saturation humidity HS as a function of
temperature. In Example 9.3-1, for 26.7°C, HS was calculated as 0.02226 kg H2O/kg air. Plotting this
point for 26.7°C (80°F) and HS = 0.02226 on Fig. 9.3-2, it falls on the 100% saturated line.

Any point below the saturation line represents unsaturated air–water vapor mixtures. The curved lines
below the 100% saturation line and running upward to the right represent unsaturated mixtures of
definite percentage humidity HP. Going downward vertically from the saturation line at a given
temperature, the line between 100% saturation and zero humidity H (the bottom horizontal line) is
divided evenly into 10 increments of 10% each.

All the percentage humidity lines HP mentioned and the saturation humidity line HS can be calculated
from the data for vapor pressure of water.

EXAMPLE 9.3-2. Use of Humidity Chart
Air entering a dryer has a temperature (dry bulb temperature) of 60°C (140°F) and a dew point
of 26.7°C (80°F). Using the humidity chart, determine the actual humidity H, percentage
humidity HP, humid heat cS, and humid volume νH in SI and English units.

S olu t ion: The dew point of 26.7°C is the temperature when the given mixture is at 100%
saturation. Starting at 26.7°C (Fig. 9.3-2), and drawing a vertical line until it intersects the
line for 100% humidity, a humidity of H = 0.0225 kg H2O/kg dry air is read off the plot. This is
the actual humidity of the air at 60°C. Stated in another way, if air at 60°C and having a
humidity H = 0.0225 is cooled, its dew point will be 26.7°C. In English units, H = 0.0225 lb
H2O/lb dry air.

Locating this point where H = 0.0225 and t = 60°C on the chart, the percentage humidity HP
is found to be 14%, by linear interpolation vertically between the 10 and 20% lines. The humid
heat for H = 0.0225 is, from Eq. (9.3-6),
The humid volume at 60°C (140°F), from Eq. (9.3-7), is

In English units,

9 .3C . Ad iab atic S atu r ation Te m p e r atu r e s

Consider the process shown in Fig. 9.3-3, where the entering gas of air–water vapor mixture is contacted
with a spray of liquid water. The gas leaves having a different humidity and temperature and the process
is adiabatic. The water is recirculated, with some makeup water added.

Figure 9.3-3. Adiabatic air–water vapor saturator.

The temperature of the water being recirculated reaches a steady-state temperature called the adiabatic
saturation temperature, TS. If the entering gas at temperature T having a humidity of H is not
saturated, TS will be lower than T. If the contact between the entering gas and the spray of droplets is
enough to bring the gas and liquid to equilibrium, the leaving air is saturated at TS, having a humidity
HS.

Writing an enthalpy balance (heat balance) over the process, a datum of TS is used. The enthalpy of the
makeup H2O is then zero. This means that the total enthalpy of the entering gas mixture = enthalpy of
the leaving gas mixture, or, using Eq. (9.3-8),
Equation 9.3-10

Or, rearranging, and using Eq. (9.3-6) for cS,

Equation 9.3-11

Equation (9.3-11) is the equation of an adiabatic humidification curve when plotted on Fig. 9.3-2, which
passes through the point HS and TS on the 100% saturation curve and other points of H and T. These
series of lines, running upward to the left, are called adiabatic humidification lines or adiabatic
saturation lines. Since cS contains the term H, the adiabatic lines are not quite straight when plotted on
the humidity chart.

If a given gas mixture at T1 and H1 is contacted for a sufficiently long time in an adiabatic saturator, it
will leave saturated at HS1 and TS1. The values of HS1 and TS1 are determined by following the adiabatic
saturation line going through point T1, H1 until it intersects the 100% saturation line. If contact is not
sufficient, the leaving mixture will be at a percentage saturation less than 100% but on the same line.

EXAMPLE 9.3-3. Adiabatic Saturation of Air
An air stream at 87.8°C having a humidity H = 0.030 kg H2O/kg dry air is contacted in an
adiabatic saturator with water. It is cooled and humidified to 90% saturation.

a.  What are the final values of H and T?

b.  For 100% saturation, what would be the values of H and T?

S olu t ion: For part (a), the point H = 0.030 and T = 87.8°C is located on the humidity chart.
The adiabatic saturation curve through this point is followed upward to the left until it
intersects the 90% line at 42.5°C and H = 0.0500 kg H2O/kg dry air.

For part (b), the same line is followed to 100% saturation, where T = 40.5°C and H = 0.0505
kg H2O/kg dry air.

9 .3D. W e t Bu lb  Te m p e r atu r e

The adiabatic saturation temperature is the steady-state temperature attained when a large amount of
water is contacted by the entering gas. The wet bulb temperature is the steady-state nonequilibrium
temperature reached when a small amount of water is contacted under adiabatic conditions by a
continuous stream of gas. Since the amount of liquid is small, the temperature and humidity of the gas
are not changed, contrary to the case of adiabatic saturation, where the temperature and humidity of the
gas are changed.

The method used to measure the wet bulb temperature is illustrated in Fig. 9.3-4, where a thermometer
is covered by a wick or cloth. The wick is kept wet by water and is immersed in a flowing stream of air–
water vapor having a temperature of T (dry bulb temperature) and humidity H. At steady state, water is
evaporating to the gas stream. The wick and water are cooled to TW and stay at this constant
temperature. The latent heat of evaporation is exactly balanced by the convective heat flowing from the
gas stream at T to the wick at a lower temperature TW.

Figure 9.3-4. Measurement of wet bulb temperature.

A heat balance on the wick can be made. The datum temperature is taken at TW. The amount of heat lost
by vaporization, neglecting the small sensible heat change of the vaporized liquid and radiation, is

Equation 9.3-12

where q is kW (kJ/s), MA is the molecular weight of water, NA is kg mol H2O evaporating/s · m2, A is

surface area m2, and λ W is the latent heat of vaporization at TW in kJ/kg H2O. In English units, q is

btu/h, NA is lb mol/h · ft 2, and λ W is btu/lbm H2O. The flux NA is

Equation 9.3-13

where   is the mass-transfer coefficient in kg mol/s · m2 · mol frac, xBM is the log mean inert mole
fraction of the air, y W is the mole fraction of water vapor in the gas at the surface, and y is the mole
fraction in the gas. For a dilute mixture xBM ≅ 1.0 and  . The relation between H and y is

Equation 9.3-14

where MB is the molecular weight of air and MA the molecular weight of H2O. Since H is small, as an
approximation,

Equation 9.3-15

Substituting Eq. (9.3-15) into (9.3-13) and then substituting the resultant into Eq. (9.3-12),

Equation 9.3-16

The rate of convective heat transfer from the gas stream at T to the wick at TW is

Equation 9.3-17

where h is the heat-transfer coefficient in kW/m2 · K (btu/h · ft 2 · °F).

Equating Eq. (9.3-16) to (9.3-17) and rearranging,

Equation 9.3-18

Experimental data on the value of h/MBky , called the psychrometric ratio, show that for water vapor–air
mixtures, the value is approximately 0.96–1.005. Since this value is close to the value of cS in Eq. (9.3-
11), approximately 1.005, Eqs. (9.3-18) and (9.3-11) are almost the same. This means that the adiabatic
saturation lines can also be used for wet bulb lines with reasonable accuracy. (Note that this is only true
for water vapor and not for other vapors, such as benzene.) Hence, the wet bulb determination is often
used to measure the humidity of an air–water vapor mixture.
EXAMPLE 9.3-4. Wet Bulb Temperature and Humidity
A water vapor–air mixture having a dry bulb temperature of T = 60°C is passed over a wet
bulb, as shown in Fig. 9.3-4, and the wet bulb temperature obtained is TW = 29.5°C. What is
the humidity of the mixture?

S olu t ion: The wet bulb temperature of 29.5°C can be assumed to be the same as the adiabatic
saturation temperature TS, as discussed. Following the adiabatic saturation curve of 29.5°C
until it reaches the dry bulb temperature of 60°C, the humidity is H = 0.0135 kg H2O/kg dry
air.
                             
                                                 
                                             
                                               
     

9.4. EQUILIBRIUM MOISTURE CONTENT OF MATERIALS

9 .4 A. Intr od u ction

As in other transfer processes, such as mass transfer, the process of drying of materials must be
approached from the viewpoint of the equilibrium relationships together with the rate relationships. In
most of the drying apparatus discussed in Section 9.2, material is dried in contact with an air–water
vapor mixture. The equilibrium relationships between the air–water vapor and the solid material will be
discussed in this section.

An important variable in the drying of materials is the humidity of the air in contact with a solid of given
moisture content. Suppose that a wet solid containing moisture is brought into contact with a stream of
air having a constant humidity H and temperature. A large excess of air is used, so its conditions remain
constant. Eventually, after exposure of the solid sufficiently long for equilibrium to be reached, the solid
will attain a definite moisture content. This is known as the equilibrium moisture content of the material
under the specified humidity and temperature of the air. The moisture content is usually expressed on a
dry basis as kg of water per kg of moisture-free (bone-dry) solid or kg H2O/100 kg dry solid; in English
units as lb H2O/100 lb dry solid.

For some solids the value of the equilibrium moisture content depends on the direction from which
equilibrium is approached. A different value for the equilibrium moisture content is obtained according
to whether a wet sample is allowed to dry by desorption or a dry sample adsorbs moisture by adsorption.
For drying calculations it is the desorption equilibrium that is the larger value and is of particular
interest.

9 .4 B. Exp e r im e ntal Data of Eq u ilib r iu m  M oistu r e  C onte nt for  Inor ganic and  Biological


M ate r ials

1. Ty p ica l d a t a  for  v a r iou s ma t er ia ls

If the material contains more moisture than its equilibrium value in contact with a gas of a given
humidity and temperature, it will dry until it reaches its equilibrium value. If the material contains less
moisture than its equilibrium value, it will adsorb water until it reaches its equilibrium value. For air
having 0% humidity, the equilibrium moisture value of all materials is zero.

The equilibrium moisture content varies greatly with the type of material for any given percent relative
humidity, as shown in Fig. 9.4-1 for some typical materials at room temperature. Nonporous insoluble
solids tend to have equilibrium moisture contents which are quite low, as shown for glass wool and
kaolin. Certain spongy, cellular materials of organic and biological origin generally show large
equilibrium moisture contents. Examples of these in Fig. 9.4-1 are wool, leather, and wood.

Figure 9.4-1. Typical equilibrium moisture contents  of some solids at approximately 298 K (25°C). [From
National Research Council, International Critical Tables, Vol. II. New York: McGraw-Hill Book Company, 1929.
Reproduced with permission of the National Academy of Sciences.]
2. Ty p ica l food  ma t er ia ls

In Fig. 9-4.2 the equilibrium moisture contents for some typical food materials are plotted versus percent
relative humidity. These biological materials also show large values for equilibrium moisture content.
Data in this figure and in Fig. 9.4-1 for biological materials show that at high percent relative humidities
of about 60 to 80%, the equilibrium moisture content increases very rapidly with increases in relative
humidity.

Figure 9.4-2. Typical equilibrium moisture contents of some food materials at approximately 298 K (25°C): (1)
macaroni, (2) flour, (3) bread, (4) crackers, (5) egg albumin. [Curve (5) from ref. (E1). Curves (1) to (4) from
National Research Council, International Critical Tables, Vol. II. New York: McGraw-Hill Book Company, 1929.
Reproduced with permission of the National Academy of Sciences.]
In general, at low relative humidities the equilibrium moisture content is greatest for food materials high
in protein, starch, or other high-molecular-weight polymers and lower for food materials high in soluble
solids. Crystalline salts and sugars as well as fats generally adsorb small amounts of water.

3. Effect  of t emp er a t u r e

The equilibrium moisture content of a solid decreases somewhat with an increase in temperature. For
example, for raw cotton at a relative humidity of 50%, the equilibrium moisture content decreased from
7.3 kg H2O/100 kg dry solid at 37.8°C (311 K) to about 5.3 at 93.3°C (366.5 K), a decrease of about 25%.
Often, for moderate temperature ranges, the equilibrium moisture content will be assumed constant
when experimental data are not available at different temperatures.

At present, theoretical understanding of the structure of solids and surface phenomena does not enable
us to predict the variation of equilibrium moisture content of various materials from first principles.
However, by using models such as those used for adsorption isotherms of multilayers of molecules and
others, attempts have been made to correlate experimental data. Henderson (H2) gives an empirical
relationship between equilibrium moisture content and percent relative humidity for some agricultural
materials. In general, empirical relationships are not available for most materials, and equilibrium
moisture contents must be determined experimentally. Also, equilibrium moisture relationships often
vary from sample to sample of the same kind of material.

9 .4 C . Bou nd  and  Unb ou nd  W ate r  in S olid s

In Fig. 9.4-1, if the equilibrium moisture content of a given material is continued to its intersection with
the 100% humidity line, the moisture is called bound water. This water in the solid exerts a vapor
pressure less than that of liquid water at the same temperature. If such a material contains more water
than indicated by intersection with the 100% humidity line, it can still exert a vapor pressure only as
high as that of ordinary water at the same temperature. This excess moisture content is called unbound
water, and it is held primarily in the voids of the solid. Substances containing bound water are often
called hygroscopic materials.

As an example, consider curve 10 for wood in Fig. 9.4-1. This intersects the curve for 100% humidity at
about 30 kg H2O/100 kg dry solid. Any sample of wood containing less than 30 kg H2O/100 kg dry solid
contains only bound water. If the wood sample contained 34 kg H2O/100 kg dry solid, 4 kg H2O would
be unbound and 30 kg H2O bound per 100 kg dry solid.

The bound water in a substance may exist under several different conditions. Moisture in cell or fiber
walls may have solids dissolved in it and have a lower vapor pressure. Liquid water in capillaries of very
small diameter will exert a lowered vapor pressure because of the concave curvature of the surface. Water
in natural organic materials is in chemical and physical–chemical combination.

9 .4 D. Fr e e  and  Eq u ilib r iu m  M oistu r e  of a S u b stance

Free moisture content in a sample is the moisture above the equilibrium moisture content. This free
moisture is the moisture that can be removed by drying under the given percent relative humidity. For
example, in Fig. 9.4-1 silk has an equilibrium moisture content of 8.5 kg H2O/100 kg dry material in
contact with air of 50% relative humidity and 25°C. If a sample contains 10 kg H2O/100 kg dry material,
only 10.0 − 8.5, or 1.5, kg H2O/100 kg dry material is removable by drying; this is the free moisture of the
sample under these drying conditions.

In many texts and references, the moisture content is given as percent moisture on a dry basis. This is
exactly the same as the kg H2O/100 kg dry material multiplied by 100.
                             
                                                 
                                             
                                               
     

9.5. RATE­OF­DRYING CURVES

9 .5A. Intr od u ction and  Exp e r im e ntal M e thod s

1. Int r od u ct ion

In the drying of various types of process materials from one moisture content to another, it is usually
desired to estimate the size of dryer needed, the various operating conditions of humidity and
temperature for the air used, and the time needed to perform the amount of drying required. As discussed
in Section 9.4, equilibrium moisture contents of various materials cannot be predicted and must be
determined experimentally. Similarly, since our knowledge of the basic mechanisms of rates of drying is
quite incomplete, it is necessary in most cases to obtain some experimental measurements of drying
rates.

2. Exp er iment a l d et er mina t ion of r a t e of d r y ing

To experimentally determine the rate of drying for a given material, a sample is usually placed on a tray.
If it is a solid material it should fill the tray so that only the top surface is exposed to the drying air
stream. By suspending the tray from a balance in a cabinet or duct through which the air is flowing, the
loss in weight of moisture during drying can be determined at different intervals without interrupting the
operation.

In doing batch-drying experiments, certain precautions should be observed to obtain usable data under
conditions that closely resemble those to be used in the large-scale operations. The sample should not be
too small in weight and should be supported in a tray or frame similar to the large-scale one. The ratio of
drying to nondrying surface (insulated surface) and the bed depth should be similar. The velocity,
humidity, temperature, and direction of the air should be the same and constant to simulate drying
under constant drying conditions.

9 .5B. R ate  of Dr ying C u r v e s for  C onstant-Dr ying C ond itions

1. C onv er sion of d a t a  t o r a t e-of-d r y ing  cu r v e

Data obtained from a batch-drying experiment are usually obtained as W total weight of the wet solid
(dry solid plus moisture) at different times t hours in the drying period. These data can be converted to
rate-of-drying data in the following ways. First, the data are recalculated. If W is the weight of the wet
solid in kg total water plus dry solid and WS is the weight of the dry solid in kg,

Equation 9.5-1

For the given constant drying conditions, the equilibrium moisture content X* kg equilibrium
moisture/kg dry solid is determined. Then the free moisture content X in kg free water/kg dry solid is
calculated for each value of Xt:

Equation 9.5-2

Using the data calculated from Eq. (9.5-2), a plot of free moisture content X versus time t in h is made, as
in Fig. 9.5-1a. To obtain the rate-of-drying curve from this plot, the slopes of the tangents drawn to the
curve in Fig. 9.5-1a can be measured, which give values of dX/dt at given values of t. The rate R is
calculated for each point by

Equation 9.5-3

Figure 9.5-1. Typical drying-rate curve for constant drying conditions: (a) plot of data as free moisture versus
time, (b) rate of drying curve as rate versus free moisture content.
where R is drying rate in kg H2O/h · m2, LS kg of dry solid used, and A exposed surface area for drying in

m2. In English units, R is lbm H2O/h · ft 2, LS is lbm dry solid, and A is ft 2. For obtaining R from Fig. 9.5-

1a, a value of LS/A of 21.5 kg/m2 was used. The drying-rate curve is then obtained by plotting R versus
the moisture content, as in Fig. 9.5-1b.

Another method for obtaining the rate-of-drying curve is to first calculate the weight loss ΔX for a Δt
time. For example, if X1 = 0.350 at a time t 1 = 1.68 h and x2 = 0.325 at a time t 2 = 2.04 h, ΔX/Δt = (0.350
− 0.325)/(2.04 − 1.68). Then, using Eq. (9.5-4) and LS/A = 21.5,

This rate R is the average over the period 1.68 to 2.04 h and should be plotted at the average
concentration X = (0.350 + 0.325)/2 = 0.338.
2. Plot  of r a t e-of-d r y ing  cu r v e

In Fig. 9.5-1b the rate-of-drying curve for constant-drying conditions is shown. At zero time the initial
free moisture content is shown at point A. In the beginning the solid is usually at a colder temperature
than its ultimate temperature, and the evaporation rate will increase. Eventually, at point B, the surface
temperature rises to its equilibrium value. Alternatively, if the solid is quite hot to start with, the rate
may start at point A'.This initial unsteady-state adjustment period is usually quite short and it is often
ignored in the analysis of times of drying.

From point B to point C in Fig. 9.5-1a the line is straight, and hence the slope and rate are constant
during this period. This constant-rate-of-drying period is shown as line BC in Fig. 9.5-1b.

At point C on both plots, the drying rate starts to decrease in the falling-rate period until it reaches point
D. In this first falling-rate period, the rate shown as line CD in Fig. 9.5-1b is often linear.

At point D the rate of drying falls even more rapidly, until it reaches point E, where the equilibrium
moisture content is X* and X = X* − X* = 0. In some materials being dried, the region CD may be missing
completely, or it may constitute all of the falling-rate period.

9 .5C . Dr ying in the  C onstant-R ate  Pe r iod

Drying of different solids under different constant conditions of drying will often give curves of different
shapes in the falling-rate period, but in general the two major portions of the drying-rate curve—
constant-rate period and falling-rate period—are present.

In the constant-rate drying period, the surface of the solid is initially very wet and a continuous film of
water exists on the drying surface. This water is entirely unbound water and it acts as if the solid were not
present. The rate of evaporation under the given air conditions is independent of the solid and is
essentially the same as the rate from a free liquid surface. Increased roughness of the solid surface,
however, may lead to higher rates than from a flat surface.

If the solid is porous, most of the water evaporated in the constant-rate period is supplied from the
interior of the solid. This period continues only as long as the water is supplied to the surface as fast as it
is evaporated. Evaporation during this period is similar to that in determining the wet bulb temperature,
and in the absence of heat transfer by radiation or conduction, the surface temperature is approximately
the same as the wet bulb temperature.

9 .5D. Dr ying in the  Falling-R ate  Pe r iod

Point C in Fig. 9.5-1b is at the critical free moisture content XC. At this point there is insufficient water
on the surface to maintain a continuous film of water. The entire surface is no longer wetted, and the
wetted area continually decreases in this first falling-rate period until the surface is completely dry, at
point D in Fig. 9.5-1b.

The second falling-rate period begins at point D when the surface is completely dry. The plane of
evaporation slowly recedes from the surface. Heat for the evaporation is transferred through the solid to
the zone of vaporization. Vaporized water moves through the solid into the air stream.

In some cases no sharp discontinuity occurs at point D, and the change from partially wetted to
completely dry conditions at the surface is so gradual that no distinct change is detectable.

The amount of moisture removed in the falling-rate period may be relatively small, but the time required
may be long. This can be seen in Fig. 9.5-1. The period BC for constant-rate drying lasts for about 3.0 h
and reduces X from 0.40 to about 0.19, a reduction of 0.21 kg H2O/kg dry solid. The falling-rate period
CE lasts about 9.0 h and reduces X only from 0.19 to 0.

9 .5E. M oistu r e  M ov e m e nts in S olid s Du r ing Dr ying in the  Falling-R ate  Pe r iod

When drying occurs by evaporation of moisture from the exposed surface of a solid, moisture must move
from the depths of the solid to the surface. The mechanisms of this movement affect the drying during
the constant-rate and falling-rate periods. Some of the theories advanced to explain the various types of
falling-rate curves will be briefly reviewed.

1. Liq u id  d iffu sion t heor y

According to this theory, diffusion of liquid moisture occurs when there is a concentration difference
between the depths of the solid and the surface. This method of transport of moisture is usually found in
nonporous solids where single-phase solutions are formed with the moisture, such as in paste, soap,
gelatin, and glue. It is also found in drying the last portions of moisture from clay, flour, wood, leather,
paper, starches, and textiles. In drying many food materials, the movement of water in the falling-rate
period also occurs by diffusion.

The shapes of the moisture-distribution curves in the solid at given times are qualitatively consistent
with the unsteady-state diffusion equations given in Chapter 7. The moisture diffusivity DAB usually
decreases with decreased moisture content, so that the diffusivities are usually average values over the
range of concentrations used. Materials drying in this way are usually said to be drying by diffusion,
although the actual mechanisms may be quite complicated. Since the rate of evaporation from the
surface is quite fast, that is, the resistance is quite low, compared to the diffusion rate through the solid
in the falling-rate period, the moisture content at the surface is at the equilibrium value.

The shape of a diffusion-controlled curve in the falling-rate period is similar to Fig. 9.5-2a. If the initial
constant-rate drying is quite high, the first falling-rate period of unsaturated surface evaporation may
not appear. If the constant-rate drying is quite low, the period of unsaturated surface evaporation is
usually present in region CD in Fig. 9.5-1b and the diffusion-controlled curve is in region DE. Equations
for calculating drying in this period where diffusion controls are given in Section 9.9. Also, Problem 7.1-4
for the drying of clay and Problem 7.1-6 for the drying of wood using diffusion theory are given in the
Chapter 7 Problems.

2. C a p illa r y  mov ement  in p or ou s solid s

When granular and porous solids such as clays, sand, soil, paint pigments, and minerals are being dried,
unbound or free moisture moves through the capillaries and voids of the solids by capillary action, not by
diffusion. This mechanism, involving surface tension, is similar to the movement of oil in a lamp wick.

Figure 9.5-2. Typical drying-rate curves: (a) diffusion-controlled falling-rate period, (b) capillary-controlled
falling-rate period in a fine porous solid.
A porous solid contains interconnecting pores and channels of varying pore sizes. As water is evaporated,
a meniscus of liquid water is formed across each pore in the depths of the solid. This sets up capillary
forces by the interfacial tension between the water and the solid. These capillary forces provide the
driving force for moving water through the pores to the surface. Small pores develop greater forces than
do large pores.

At the beginning of the falling-rate period at point C in Fig. 9.5-1b, the water is being brought to the
surface by capillary action, but the surface layer of water starts to recede below the surface. Air rushes in
to fill the voids. As the water is continuously removed, a point is reached where there is insufficient water
left to maintain continuous films across the pores, and the rate of drying suddenly decreases at the start
of the second falling-rate period at point D. Then the rate of diffusion of water vapor in the pores and rate
of conduction of heat in the solid may become the main factors in drying.

In fine pores in solids, the rate-of-drying curve in the second falling-rate period may conform to the
diffusion law; the curve is concave upward, as shown in Fig. 9.5-2b. For very porous solids, such as a bed
of sand, where the pores are large, the rate-of-drying curve in the second falling-rate period is often
straight, and hence the diffusion equations do not apply.

3. Effect  of shr ink a g e

A factor often greatly affecting the drying rate is the shrinkage of the solid as moisture is removed. Rigid
solids do not shrink appreciably, but colloidal and fibrous materials such as vegetables and other
foodstuffs do undergo shrinkage. The most serious effect is that there may be developed a hard layer on
the surface which is impervious to the flow of liquid or vapor moisture and slows the drying rate;
examples are clay and soap. In many foodstuffs, if drying occurs at too high a temperature, a layer of
closely packed, shrunken cells, which are sealed together, forms at the surface. This presents a barrier to
moisture migration and is known as case hardening. Another effect of shrinkage is to cause the material
to warp and change its structure. This can happen in drying wood.

Sometimes, to decrease these effects of shrinkage, it is desirable to dry with moist air. This decreases the
rate of drying so that the effects of shrinkage on warping or hardening at the surface are greatly reduced.
                             
                                                 
                                             
                                               
     

9.6. CALCULATION METHODS FOR CONSTANT­RATE DRYING
PERIOD

9 .6 A. M e thod  Using Exp e r im e ntal Dr ying C u r v e

1. Int r od u ct ion

Probably the most important factor in drying calculations is the length of time required to dry a material
from a given initial free moisture content X1 to a final moisture content X2. For drying in the constant-
rate period, we can estimate the time needed by using experimental batch-drying curves or by using
predicted mass- and heat-transfer coefficients.

2. M et ho d  u sing  d r y ing  cu r v e

To estimate the time of drying for a given batch of material, the best method is based on actual
experimental data obtained under conditions where the feed material, relative exposed surface area, gas
velocity, temperature, and humidity are essentially the same as in the final drier. Then the time required
for the constant-rate period can be determined directly from the drying curve of free moisture content
versus time.

EXAMPLE 9.6­1. Time of Drying from Drying Curve
A solid whose drying curve is represented by Fig. 9.5-1a is to be dried from a free moisture
content X1 = 0.38 kg H2O/kg dry solid to X2 = 0.25 kg H2O/kg dry solid. Estimate the time
required.

S olu t ion: From Fig. 9.5-1a for X1 = 0.38, t 1 is read off as 1.28 h. For X2 = 0.25, t 2 = 3.08 h.


Hence, the time required is

3. M et ho d  u sing  r a t e-of-d r y ing  cu r v e for  const a nt -r a t e p er iod

Instead of using the drying curve, the rate-of-drying curve can be used. The drying rate R is defined by
Eq. (9.5-3) as

Equation 9.5-3
This can be rearranged and integrated over the time interval for drying from X1 at t 1 = 0 to X2 at t 2 = t:

Equation 9.6-1

If the drying takes place within the constant-rate period, so that both X1 and X2 are greater than the
critical moisture content XC, then R = constant = RC. Integrating Eq. (9.6-1) for the constant-rate period,

Equation 9.6-2

EXAMPLE 9.6-2. Drying Time from Rate-of-Drying Curve
Repeat Example 9.6-1 but use Eq. (9.6-2) and Fig. 9.5-1b.

S olu t ion: As stated previously, a value of 21.5 for LS/A was used to prepare Fig. 9.5-1b from

9.5-1a. From Fig. 9.5-1b, RC = 1.51 kg H2O/h · m2. Substituting into Eq. (9.6-2),

This is close to the value of 1.80 h in Example 9.6-1.

9 .6 B. M e thod  Using Pr e d icte d  Tr ansfe r  C oe fficie nts for  C onstant-R ate  Pe r iod

1. Int r od u ct ion

In the constant-rate period of drying, the surfaces of the grains of solid in contact with the drying air flow
remain completely wetted. As stated previously, the rate of evaporation of moisture under a given set of
air conditions is independent of the type of solid and is essentially the same as the rate of evaporation
from a free liquid surface under the same conditions. However, surface roughness may increase the rate of
evaporation.

During this constant-rate period, the solid is so wet that the water acts as if the solid were not there. The
water evaporated from the surface is supplied from the interior of the solid. The rate of evaporation from
a porous material occurs by the same mechanism as that occurring at a wet bulb thermometer, which is
essentially constant-rate drying.

2. Eq u a t ions for  p r ed ict ing  const a nt -r a t e d r y ing

Drying of a material occurs by mass transfer of water vapor from the saturated surface of the material
through an air film to the bulk gas phase or environment. The rate of moisture movement within the
solid is sufficient to keep the surface saturated. The rate of removal of the water vapor (drying) is
controlled by the rate of heat transfer to the evaporating surface, which furnishes the latent heat of
evaporation for the liquid. At steady state, the rate of mass transfer balances the rate of heat transfer.

To derive the equation for drying, we neglect heat transfer by radiation to the solid surface and also
assume no heat transfer by conduction from metal pans or surfaces. Conduction and radiation will be
considered in Section 9.8. Assuming only heat transfer to the solid surface by convection from the hot gas
to the surface of the solid and mass transfer from the surface to the hot gas (Fig. 9.6-1), we can write
equations which are the same as those for deriving the wet bulb temperature TW in Eq. (9.3-18).

Figure 9.6-1. Heat and mass transfer in constant-rate drying.

The rate of convective heat transfer q in W (J/s, btu/h) from the gas at T°C (°F) to the surface of the solid
at TW°C, where (T − TW)°C = (T − TW) K is

Equation 9.6-3

where h is the heat-transfer coefficient in W/m2 · K (btu/h · ft 2 · °F) and A is the exposed drying area in
m2 (ft 2). The equation of the flux of water vapor from the surface is the same as Eq. (9.3-13) and is

Equation 9.6-4

Using the approximation from Eq. (9.3-15) and substituting into Eq. (9.6-4),

Equation 9.6-5

The amount of heat needed to vaporize NA kg mol/s · m2 (lb mol/h · ft 2) water, neglecting the small
sensible heat changes, is the same as Eq. (9.3-12):
Equation 9.6-6

where λ W is the latent heat at TW in J/kg (btu/lbm).

Equating Eqs. (9.6-3) and (9.6-6) and substituting Eq. (9.6-5) for NA,

Equation 9.6-7

Equation (9.6-7) is identical to Eq. (9.3-18) for the wet bulb temperature. Hence, in the absence of heat
transfer by conduction and radiation, the temperature of the solid is at the wet bulb temperature of the
air during the constant-rate drying period. Thus, the rate of drying RC can be calculated using the heat-
transfer equation h(T − TW)/λ W or the mass-transfer equation ky MB(HW − H). However, it has been
found more reliable to use the heat-transfer equation (9.6-8), since an error in determining the interface
temperature TW at the surface affects the driving force (T − TW) much less than it affects (HW − H).

Equation 9.6-8

To predict RC in Eq. (9.6-8), the heat-transfer coefficient must be known. For the case where the air is
flowing parallel to the drying surface, Eq. (4.6-3) can be used for air. However, because the shape of the
leading edge of the drying surface causes more turbulence, the following can be used for an air
temperature of 45–150°C and a mass velocity G of 2450–29 300 kg/h · m2 (500–6000 lbm/h · ft 2) or a
velocity of 0.61–7.6 m/s (2–25 ft/s):

Equation 9.6-9

where in SI units G is νρ kg/h · m2 and h is W/m2 · K. In English units, G is in lbm/h · ft 2 and h in btu/h ·

ft 2 · °F. When air flows perpendicular to the surface for a G of 3900–19 500 kg/h · m2 or a velocity of
0.9–4.6 m/s (3–15 ft/s),

Equation 9.6-10
Equations (9.6-8)–(9.6-10) can be used to estimate the rate of drying during the constant-rate period.
However, when possible, experimental measurements of the drying rate are preferred.

To estimate the time of drying during the constant-rate period, substituting Eq. (9.6-7) into (9.6-2),

Equation 9.6-11

EXAMPLE 9.6-3. Prediction of Constant-Rate Drying
An insoluble wet granular material is dried in a pan 0.457 × 0.457 m (1.5 × 1.5 ft) and 25.4
mm deep. The material is 25.4 mm deep in the pan, and the sides and bottom can be
considered to be insulated. Heat transfer is by convection from an air stream flowing parallel
to the surface at a velocity of 6.1 m/s (20 ft/s). The air is at 65.6°C (150°F) and has a humidity
of 0.010 kg H2O/kg dry air. Estimate the rate of drying for the constant-rate period using SI
and English units.

S olu t ion: For a humidity H = 0.010 and dry bulb temperature of 65.6°C, using the humidity
chart, Fig. 9.3-2, the wet bulb temperature TW is found to be 28.9°C (84°F) and HW = 0.026
by following the adiabatic saturation line (the same as the wet bulb line) to the saturated
humidity. Using Eq. (9.3-7) to calculate the humid volume,

The density for 1.0 kg dry air + 0.010 kg H2O is

The mass velocity G is
Using Eq. (9.6-9),

At TW = 28.9°C (84°F), λ W = 2433 kJ/kg (1046 btu/lbm) from steam tables.

Substituting into Eq. (9.6-8) and noting that (65.6 − 28.9)°C = (65.6 − 28.9) K,

The total evaporation rate for a surface area of 0.457 × 0.457 m2 is

9 .6 C . Effe ct of Pr oce ss Var iab le s on C onstant-R ate  Pe r iod

As stated previously, experimental measurements of the drying rate are usually preferred over using the
equations for prediction. However, these equations are quite helpful in predicting the effect of changing
the drying-process variables when limited experimental data are available.

1. Effect  of a ir  v elocit y

When conduction and radiation heat transfer are not present, the rate RC of drying in the constant-rate

region is proportional to h and hence to G0.8 as given by Eq. (9.6-9) for air flow parallel to the surface.
The effect of gas velocity is less important when radiation and conduction are present.

2. Effect  of g a s hu mid it y

If the gas humidity H is decreased for a given T of the gas, then from the humidity chart the wet bulb
temperature TW will decrease. Then, using Eq. (9.6-7), RC will increase. For example, if the original
conditions are RC1, T1, TW1, H1, and HW1, then if H1 is changed to H2 and HW1 is changed to HW2, RC2
becomes

Equation 9.6-12
However, since λ W1 ≅ λ W2,

Equation 9.6-13

3. Effect  of g a s t emp er a t u r e

If the gas temperature T is increased, TW is also increased somewhat, but not as much as the increase in
T. Hence, RC increases as follows:

Equation 9.6-14

4 . Effect  of t hick ness of solid  b eing  d r ied

For heat transfer by convection only, the rate RC is independent of the thickness x1 of the solid. However,
the time t for drying between fixed moisture contents X1 and X2 will be directly proportional to the
thickness x1. This is shown by Eq. (9.6-2), where increasing the thickness with a constant A will directly
increase the amount of LS kg dry solid.

5. Exp er iment a l effect  of p r ocess v a r ia b les

Experimental data tend to bear out the conclusions reached on the effects of material thickness,
humidity, air velocity, and T − TW.
                             
                                                 
                                             
                                               
     

9.7. CALCULATION METHODS FOR FALLING­RATE DRYING
PERIOD

9 .7A. M e thod  Using Nu m e r ical Inte gr ation

In the falling-rate drying period, as shown in Fig. 9.5-1b, the rate of drying R is not constant but
decreases when drying proceeds past the critical free moisture content XC. When the free moisture
content X is zero, the rate drops to zero.

The time of drying for any region between X1 and X2 has been given by Eq. (9.6-1):

Equation 9.6-1

If the rate is constant, Eq. (9.6-1) can be integrated to give Eq. (9.6-2). However, in the falling-rate
period, R varies. For any shape of falling-rate drying curve, Eq. (9.6-1) can be integrated by plotting 1/R
versus X and determining the area under the curve using graphical integration or numerical integration
with a spreadsheet. (See Section 1.8 for methods of numerical integration.)

EXAMPLE 9.7­1. Numerical Integration in Falling­Rate
Period
A batch of wet solid whose drying-rate curve is represented by Fig. 9.5-1b is to be dried from a
free moisture content of X1 = 0.38 kg H2O/kg dry solid to X2 = 0.04 kg H2O/kg dry solid. The

weight of the dry solid is LS = 399 kg dry solid and A = 18.58 m2 of top drying surface.

Calculate the time for drying. Note that LS/A = 399/18.58 = 21.5 kg/m2.

S olu t ion: From Fig. 9.5-1b, the critical free moisture content is XC = 0.195 kg H2O/kg dry
solid. Hence, the drying occurs in the constant-rate and falling-rate periods.

For the constant-rate period, X1 = 0.38 and X2 = XC = 0.195. From Fig. 9.5-1b, RC = 1.51 kg

H2O/hm2. Substituting into Eq. (9.6-2),

For the falling-rate period, reading values of R for various values of X from Fig. 9.5-1b, the
following table is prepared:

X R 1/R X R 1/R
0.195 1.51 0.663 0.065 0.71 1.41

0.150 1.21 0.826 0.050 0.37 2.70

0.100 0.90 1.11 0.040 0.27 3.70

To determine this area by numerical integration using a spreadsheet, the calculations are
given in the following table:

X R 1/R ΔX (1/R)av   (ΔX)(1/R)av

0.195 0.51 0.663 0.045 0.745   0.0335


0.150 1.21 0.826 0.050 0.969   0.0485
0.100 0.90 1.111 0.035 1.260   0.0441

0.065 0.71 1.408 0.015 2.055   0.0308


0.050 0.37 2.702 0.010 3.203   0.0320

0.040 0.27 3.704   Total = 0.1889

The area of the first rectangle is the average height (0.663 + 0.826)/2, or 0.745, times the
width ΔX (0.195 − 0.150), or 0.045, giving 0.0335. Other values are similarly calculated,
giving a total of 0.1889.

Substituting into Eq. (9.6-1),

The total time is 2.63 + 4.06 = 6.69 h.

9 .7B. C alcu lation M e thod s for  S p e cial C ase s in Falling-R ate  R e gion

In certain special cases in the falling-rate region, the equation for the time of drying, Eq. (9.6-1), can be
integrated analytically.

1. R a t e is a  linea r  fu nct ion of X

If both X1 and X2 are less than XC and the rate R is linear in X over this region,

Equation 9.7-1

where a is the slope of the line and b is a constant. Differentiating Eq. (9.7-1) gives dR = a dX.
Substituting this into Eq. (9.6-1),

Equation 9.7-2
Since R1 = aX1 + b and R2 = aX2 + b,

Equation 9.7-3

Substituting Eq. (9.7-3) into (9.7-2),

Equation 9.7-4

2. R a t e is a  linea r  fu nct ion t hr ou g h or ig in

In some cases a straight line from the critical moisture content passing through the origin adequately
represents the whole falling-rate period. In Fig. 9.5-1b this would be a straight line from C to E at the
origin. Often, for lack of more detailed data, this assumption is made. Then, for a straight line through
the origin, where the rate of drying is directly proportional to the free moisture content,

Equation 9.7-5

Differentiating, dX = dR/a. Substituting into Eq. (9.6-1),

Equation 9.7-6

The slope a of the line is RC/XC, and for X1 = XC at R1 = RC,

Equation 9.7-7

Noting also that RC/R2 = XC/X2,
Equation 9.7-8

or

Equation 9.7-9

EXAMPLE 9.7-2. Approximation of Straight Line for
Falling-Rate Period
Repeat Example 9.7-1, but as an approximation assume a straight line for the rate R versus X
through the origin from point XC to X = 0 for the falling-rate period.

S olu t ion: RC = 1.51 kg H2O/h · m2 and XC = 0.195. Drying in the falling-rate region is from
XC to X2 = 0.040. Substituting into Eq. (9.7-8),

This value of 4.39 h compares favorably with the value of 4.06 h obtained in Example 9.7-1 by
numerical integration.
                             
                                                 
                                             
                                               
     

9.8. COMBINED CONVECTION, RADIATION, AND CONDUCTION
HEAT TRANSFER IN CONSTANT­RATE PERIOD

9 .8A. Intr od u ction

In Section 9.6B an equation was derived for predicting the rate of drying in the constant-rate period.
Equation (9.6-7) was derived assuming heat transfer to the solid by convection only from the
surrounding air to the drying surface. Often the drying is done in an enclosure, where the enclosure
surface radiates heat to the drying solid. Also, in some cases the solid may be resting on a metal tray, and
heat transfer by conduction through the metal to the bottom of the solid may occur.

9 .8B. De r iv ation of Eq u ation for  C onv e ction, C ond u ction, and  R ad iation

In Fig. 9.8-1 a solid material being dried by a stream of air is shown. The total rate of heat transfer to the
drying surface is

Equation 9.8-1

Figure 9.8-1. Heat and mass tr ansfer in drying a solid fr om the top surface.

where qC is the convective heat transfer from the gas at T°C to the solid surface at TS°C in W (J/s), qR is
the radiant heat transfer from the surface at TR to TS in W (J/s), and qK is the rate of heat transfer by
conduction from the bottom in W. The rate of convective heat transfer is similar to Eq. (9.6-3) and is as
follows, where (T − TS)°C = (T − TS) K:

Equation 9.8-2
where A is the exposed surface area in m2. The radiant heat transfer is

Equation 9.8-3

where hR is the radiant-heat-transfer coefficient defined by Eq. (4.10-10):

Equation 4.10-10

Note that in Eq. (4.10-10) TR and TS are in K. For the heat transfer by conduction from the bottom, the
heat transfer is first by convection from the gas to the metal plate, then by conduction through the metal,
and finally by conduction through the solid. Radiation to the bottom of the tray is often small if the tray
is placed above another tray, and it will be neglected here. Also, if the gas temperatures are not too high,
radiation from the top surface to the tray will be small. Hence, the heat by radiation should not be
overemphasized. The heat by conduction is

Equation 9.8-4

Equation 9.8-5

where zM is the metal thickness in m, kM the metal thermal conductivity in W/m · K, zS the solid
thickness in m, and kS the solid thermal conductivity. The value of hC in Eq. (9.8-4) is assumed to be the
same as in Eq. (9.8-2).

The equation for the rate of mass transfer is similar to Eq. (9.6-5) and is

Equation 9.8-6
Also, rewriting Eq. (9.6-6),

Equation 9.8-7

Combining Eqs. (9.8-1), (9.8-2), (9.8-3), (9.8-4), (9.8-6), and (9.8-7),

Equation 9.8-8

This equation can be compared to Eq. (9.6-7), which gives the wet bulb temperature TW when radiation
and conduction are absent. Equation (9.8-8) gives surface temperature TS greater than the wet bulb
temperature TW. Equation (9.8-8) must also intersect the saturated humidity line at TS and HS, and TS
> TW and HS > HW. The equation must be solved by trial and error.

To facilitate solution of Eq. (9.8-8), it can be rearranged (T1) in the following way:

Equation 9.8-9

The ratio hC/ky MB was shown in the wet bulb derivation of Eq. (9.3-18) to be approximately cS in Eq.
(9.3-6):

Equation 9.3-6

EXAMPLE 9.8-1. Constant-Rate Drying When Radiation,
Conduction, and Convection Are Present
An insoluble granular material wet with water is being dried in a pan 0.457 × 0.457 m and
25.4 mm deep. The material is 25.4 mm deep in the metal pan, which has a metal bottom of
thickness zM = 0.610 mm having a thermal conductivity kM = 43.3 W/m · K. The thermal
conductivity of the solid can be assumed as kS = 0.865 W/m · K. Heat transfer is by convection
from an air stream flowing parallel to the top drying surface and the bottom metal surface at a
velocity of 6.1 m/s and having a temperature of 65.6°C and humidity H = 0.010 kg H2O/kg
dry air. The top surface also receives direct radiation from steam-heated pipes whose surface
temperature TR = 93.3°C. The emissivity of the solid is є = 0.92. Estimate the rate of drying for
the constant-rate period.
S olu t ion: Some of the given values are as follows:

The velocity, temperature, and humidity of the air are the same as in Example 9.6-3 and the
convective coefficient was predicted as hC = 62.45 W/m2 · K.

The solution of Eq. (9.8-9) is by trial and error. The temperature TS will be above the wet bulb
temperature of TW = 28.9°C and will be estimated as TS = 32.2°C. Then λ S = 2424 kJ/kg from
the steam tables. To predict hR from Eq. (4.10-10) for є = 0.92, Tl = 93.3 + 273.2 = 366.5 K,
and T2 = 32.2 + 273.2 = 305.4 K,

Using Eq. (9.8-5),

From Eq. (9.3-6),

This can be substituted for (hC/ky MB) into Eq. (9.8-9). Also, substituting other knowns,

Equation 9.8-10

For TS assumed as 32.2°C, λ S = 2424 × 103 J/kg. From the humidity chart for TS = 32.2°C, the
saturation humidity HS = 0.031. Substituting into Eq. (9.8-10) and solving for TS,
For the second trial, assuming that TS = 32.5°C, λ S = 2423 × 103, and HS from the humidity
chart at saturation is 0.032. Substituting into Eq. (9.8-10) while assuming that hR does not
change appreciably, a value of TS = 32.8°C is obtained. Hence, the final value is 32.8°C. This is
3.9°C greater than the wet bulb temperature of 28.9°C in Example 9.6-3, where radiation and
conduction were absent.

Using Eq. (9.8-8),

This compares favorably with 3.39 kg/h · m2 for Example 9.6-3 for no radiation or conduction.
                             
                                                 
                                             
                                               
     

9.9. DRYING IN FALLING­RATE PERIOD BY DIFFUSION AND
CAPILLARY FLOW

9 .9 A. Intr od u ction

In the falling-rate period, the surface of the solid being dried is no longer completely wetted, and the rate
of drying steadily falls with time. In Section 9.7 empirical methods were used to predict the time of
drying. In one method the actual rate-of-drying curve was numerically or graphically integrated to
determine the time of drying.

In another method an approximately straight line from the critical free moisture content to the origin at
zero free moisture was assumed. Here the rate of drying was assumed to be a linear function of the free
moisture content. The rate of drying R is defined by Eq. (9.5-3):

Equation 9.5-3

When R is a linear function of X in the falling-rate period,

Equation 9.7-5

where a is a constant. Equating Eq. (9.7-5) to Eq. (9.5-3),

Equation 9.9-1

Rearranging,

Equation 9.9-2

In many instances, however, as mentioned briefly in Section 9.5E, the rate of moisture movement in the
falling-rate period is governed by the rate of internal movement of the liquid by liquid diffusion or by
capillary movement. These two mechanisms of moisture movement will be considered in more detail and
the theories related to experimental data in the falling-rate region.

9 .9 B. Liq u id  Diffu sion of M oistu r e  in Dr ying

When liquid diffusion of moisture controls the rate of drying in the falling-rate period, the equations for
diffusion described in Chapter 7 can be used. Using the concentrations as X kg free moisture/kg dry solid
instead of kg mol moisture/m3, Fick's second law for unsteady-state diffusion, Eq. (7.10-10), can be
written as

Equation 9.9-3

where DL is the liquid diffusion coefficient in m2/h and x is distance in the solid in m.

This type of diffusion is often characteristic of relatively slow drying in nongranular materials such as
soap, gelatin, and glue, and in the later stages of drying of bound water in clay, wood, textiles, leather,
paper, foods, starches, and other hydrophilic solids.

A major difficulty in analyzing diffusion drying data is that the initial moisture distribution is not
uniform throughout the solid at the start if a drying period at constant rate precedes this falling-rate
period. During diffusion-type drying, the resistance to mass transfer of water vapor from the surface is
usually very small, and the diffusion in the solid controls the rate of drying. Then the moisture content at
the surface is at the equilibrium value X*. This means that the free moisture content X at the surface is
essentially zero.

Assuming that the initial moisture distribution is uniform at t = 0, Eq. (9.9-3) may be integrated by the
methods in Chapter 7 to give the following:

Equation 9.9-4

[View full size image]

where X = average free moisture content at time t h, X1 = initial free moisture content at t = 0, X* =

equilibrium free moisture content, x1 =   the thickness of the slab when drying occurs from the top and
bottom parallel faces, and x1 = total thickness of slab if drying occurs only from the top face.

Equation (9.9-4) assumes that DL is constant, but DL is rarely constant; it varies with moisture content,
temperature, and humidity. For long drying times, only the first term in Eq. (9.9-4) is significant, and
the equation becomes

Equation 9.9-5
Solving for the time of drying,

Equation 9.9-6

In this equation, if the diffusion mechanism starts at X = XC, then X1 = XC. Differentiating Eq. (9.9-6)
with respect to time and rearranging,

Equation 9.9-7

Multiplying both sides by −LS/A,

Equation 9.9-8

Hence, Eqs. (9.9-7) and (9.9-8) state that when internal diffusion controls for long periods of time, the
rate of drying is directly proportional to the free moisture X and the liquid diffusivity, and that the rate of
drying is inversely proportional to the thickness squared. Or, stated as the time of drying between fixed
moisture limits, the time varies directly as the square of the thickness. The drying rate should be
independent of gas velocity and humidity.

EXAMPLE 9.9-1. Drying Slabs of Wood When Diffusion of
Moisture Controls
The experimental average diffusion coefficient of moisture in a given wood is 2.97 × 10−6 m2/h
(3.20 × 10−5 ft 2/h). Large planks of wood 25.4 mm thick are dried from both sides by air
having a humidity such that the equilibrium moisture content in the wood is X* = 0.04 kg
H2O/kg dry wood. The wood is to be dried from a total average moisture content of Xt1 = 0.29
to Xt = 0.09. Calculate the time needed.

S olu t ion: The free moisture content X1 = Xt1 − X* = 0.29 − 0.04 = 0.25, X = Xt − X* = 0.09 −
0.04 = 0.05. The half-slab thickness x1 = 25.4/(2 × 1000) = 0.0127 m. Substituting into Eq.
(9.9-6),
Alternatively, Fig. 5.3-13 for the average concentration in a slab can be used. The ordinate Ea  =

X/X1 = 0.05/0.25 = 0.20. Reading off the plot a value of 0.56 =  , substituting, and
solving for t,

9 .9 C . C ap illar y M ov e m e nt of M oistu r e  in Dr ying

Water can flow from regions of high concentration to those of low concentration as a result of capillary
action rather than by diffusion if the pore sizes of the granular materials are suitable.

The capillary theory (P1) assumes that a packed bed of nonporous spheres contains a void space between
the spheres called pores. As water is evaporated, capillary forces are set up by the interfacial tension
between the water and the solid. These forces provide the driving force for moving the water through the
pores to the drying surface.

A modified form of Poiseuille's equation for laminar flow can be used in conjunction with the capillary-
force equation to derive an equation for the rate of drying when flow is by capillary movement. If the
moisture movement follows the capillary-flow equations, the rate of drying R will vary linearly with X.
Since the mechanism of evaporation during this period is the same as during the constant-rate period,
the effects of the variables gas velocity, temperature of the gas, humidity of the gas, and so on, will be the
same as for the constant-rate drying period.

The defining equation for the rate of drying is

Equation 9.5-3

For the rate R varying linearly with X, given previously,

Equation 9.7-9
Equation 9.7-8

We define t as the time when X = X2 and

Equation 9.9-9

where ρS = solid density kg dry solid/m3. Substituting Eq. (9.9-9) and X = X2 into Eq. (9.7-8),

Equation 9.9-10

Substituting Eq. (9.6-7) for RC,

Equation 9.9-11

Hence, Eqs. (9.9-10) and (9.9-11) state that when capillary flow controls in the falling-rate period, the
rate of drying is inversely proportional to the thickness. The time of drying between fixed moisture limits
varies directly as the thickness and depends upon the gas velocity, temperature, and humidity.

9 .9 D. C om p ar ison of Liq u id  Diffu sion and  C ap illar y Flow

To determine the mechanism of drying in the falling-rate period, the experimental data obtained for
moisture content at various times using constant drying conditions are often analyzed as follows. The
unaccomplished moisture change, defined as the ratio of free moisture present in the solid after drying
for t hours to the total free moisture content present at the start of the falling-rate period, X/XC, is plotted
versus time on semilog paper. If a straight line is obtained, such as curve B in Fig. 9.9-1 using the upper
scale for the abscissa, then either Eqs. (9.9-4)–(9.9-6) for diffusion or Eqs. (9.9-10) and (9.9-11) for
capillary flow are applicable.

Figure 9.9-1. Plot of equations for falling-rate period: (A) Eq. (9.9-4) for moisture movement by diffusion, (B)
Eq. (9.9-10) for moisture movement by capillary flow. (From R. H. Perry and C. H. Chilton, Chemical Engineers
Handbook, 5th ed. New York: McGraw-Hill Book Company, 1973. With permission.)
If the equations for capillary flow apply, the slope of the falling-rate drying line B in Fig. 9.9-1 is related
to Eq. (9.9-10), which contains the constant drying rate RC. The value of RC is calculated from the
measured slope of the line, which is −RC/x1ρSXC, and if it agrees with the experimental value of RC in the
constant-drying period or the predicted value of RC, the moisture movement is by capillary flow.

If the values of RC do not agree, the moisture movement is by diffusion and the slope of line B in Fig. 9.9-

1 from Eq. (9.9-6) should equal −π2DL/4 . In actual practice, however, the diffusivity DL is usually
less at small moisture contents than at large moisture contents, and an average value of DL is usually
determined experimentally over the moisture range of interest. A plot of Eq. (9.9-4) is shown as line A,

where ln(X/X1) or ln(X/XC) is plotted versus DLt/ . This is the same plot as Fig. 5.3-13 for a slab and
shows a curvature in the line for values of X/XC between 1.0 and 0.6 and a straight line for X/XC < 0.6.

When the experimental data show that the movement of moisture follows the diffusion law, the average
experimental diffusivities can be calculated as follows for different concentration ranges. A value of X/XC
is chosen at 0.4, for example. From an experimental plot similar to curve B, Fig. 9.9-1, the experimental

value of t is obtained. From curve A at X/XC = 0.4, the theoretical value of (DLt/ )theor  is obtained.


Then, by substituting the known values of t and x1 into Eq. (9.9-12), the experimental average value of
DL over the range X/XC = 1.0–0.4 is obtained:

Equation 9.9-12
This is repeated for various values of X/XC. Values of DL obtained for X/XC > 0.6 are in error because of
the curvature of line A.

EXAMPLE 9.9-2. Diffusion Coefficient in the Tapioca Root
Tapioca flour is obtained from drying and then milling the tapioca root. Experimental data on
drying thin slices of the tapioca root 3 mm thick on both sides in the falling-rate period under
constant-drying conditions are tabulated below. The time t = 0 is the start of the falling-rate
period.

X/XC t (h) X/XC t (h) X/XC t (h)

1.0 0 0.55 0.40 0.23 0.94


0.80 0.15 0.40 0.60 0.18 1.07

0.63 0.27 0.30 0.80    

It has been determined that the data do not follow the capillary-flow equations but appear to
follow the diffusion equations. Plot the data as X/XC versus t on semilog coordinates and
determine the average diffusivity of the moisture up to a value of X/XC = 0.20.

S olu t ion: In Fig. 9.9-2 the data are plotted as X/XC on the log scale versus t on a linear scale
and a smooth curve is drawn through the data. At X/XC = 0.20, a value of t = 1.02 h is read off
the plot. The value of x1 = 3 mm/2 = 1.5 mm for drying from both sides. From Fig. 9.9-1, line

A, for X/XC = 0.20, (DLt/ )theor  = 0.56. Then substituting into Eq. (9.9-12),

Figure 9.9-2. Plot of drying data for Example 9.9-2.
                             
                                                 
                                             
                                               
     

9.10. EQUATIONS FOR VARIOUS TYPES OF DRYERS

9 .10A. Thr ou gh-C ir cu lation Dr ying in Packe d  Be d s

For through-circulation drying, where the drying gas passes upward or downward through a bed of wet
granular solids, both a constant-rate period and a falling-rate period of drying may result. Often the
granular solids are arranged on a screen so that the gas passes through the screen and through the open
spaces or voids between the solid particles.

1. Der iv a t ion of eq u a t ions

To derive the equations for this case, no heat losses will be assumed, so the system is adiabatic. The
drying will be for unbound moisture in the wet granular solids. We shall consider a bed of uniform cross-
sectional area A m2, where a gas flow of G kg dry gas/h · m2 cross section enters with a humidity of H1.
By a material balance on the gas at a given time, the gas leaves the bed with a humidity H2. The amount
of water removed from the bed by the gas is equal to the rate of drying at this time:

Equation 9.10-1

where R = kg H2O/h · m2 cross section and G = kg dry air/h · m2 cross section.

In Fig. 9.10-1 the gas enters at T1 and H1 and leaves at T2 and H2. Hence, the temperature T and
humidity H both vary through the bed. Making a heat balance over the short section dz m of the bed,

Equation 9.10-2

Figure 9.10-1. Heat and material balances in a through­ circulation dryer in a packed bed.
where A = m2 cross-sectional area, q is the heat-transfer rate in W (J/s), and cS is the humid heat of the

air–water vapor mixture in Eq. (9.3-6). Note that G in this equation is in kg/s · m2. The heat-transfer
equation gives

Equation 9.10-3

where TW = wet bulb temperature of solid, h is the heat-transfer coefficient in W/m2 · K, and a is m2

surface area of solids/m3 bed volume. Equating Eq. (9.10-2) to (9.10-3), rearranging, and integrating,

Equation 9.10-4

Equation 9.10-5

where z = bed thickness = x1 m.

For the constant-rate period of drying by air flowing parallel to a surface, Eq. (9.6-11) was derived:

Equation 9.6-11

Using Eq. (9.9-9) and the definition of a, we obtain
Equation 9.10-6

Substituting Eq. (9.10-6) into (9.6-11) and setting X2 = XC for drying to XC, we obtain the equation for
through-circulation drying in the constant-rate period:

Equation 9.10-7

In a similar manner, Eq. (9.7-8) for the falling-rate period, which assumes that R is proportional to X,
becomes, for through-circulation drying,

Equation 9.10-8

Both Eqs. (9.10-7) and (9.10-8), however, hold for only one point in the bed in Fig. 9.10-1, since the
temperature T of the gas varies throughout the bed. Hence, in a manner similar to the derivation in heat
transfer, a log mean temperature difference can be used as an approximation for the whole bed in place of
T − TW in Eqs. (9.10-7) and (9.10-8):

Equation 9.10-9

Substituting Eq. (9.10-5) for the denominator of Eq. (9.10-9) and substituting the value of T2 from Eq.
(9.10-5) into (9.10-9),

Equation 9.10-10

Substituting Eq. (9.10-10) into (9.10-7) for the constant-rate period and setting x1 = z,

Equation 9.10-11
Similarly, for the falling-rate period an approximate equation is obtained:

Equation 9.10-12

A major difficulty with the use of Eq. (9.10-12) is that the critical moisture content is not easily
estimated. Different forms of Eqs. (9.10-11) and (9.10-12) can also be derived, using humidity instead of
temperature (T1).

2. Hea t -t r a nsfer  coefficient s

For through-circulation drying, where the gases pass through a bed of wet granular solids, the following
equations for estimating h for adiabatic evaporation of water can be used (G1, W1):

Equation 9.10-13

Equation 9.10-14

where h is in W/m2 · K, Dp is diameter in m of a sphere having the same surface area as the particle in the

bed, Gt is the total mass velocity entering the bed in kg/h · m2, and μ is viscosity in kg/m · h. In English

units, h is btu/h · ft 2 · °F, Dp is ft, Gt is lbm/h · ft 2, and μ is lbm/ft · h.

3. G eomet r y  fa ct or s in a  b ed

To determine the value of a, m2 surface area/m3 of bed, in a packed bed for spherical particles having a
diameter Dp m,

Equation 9.10-15
where ε is the void fraction in the bed. For cylindrical particles,

Equation 9.10-16

where Dc is diameter of cylinder in m and h is length of cylinder in m. The value of Dp to use in Eqs.
(9.10-13) and (9.10-14) for a cylinder is the diameter of a sphere having the same surface area as the
cylinder, as follows:

Equation 9.10-17

4 . Eq u a t ions for  v er y  fine p a r t icles

The equations derived for the constant- and falling-rate periods in packed beds hold for particles of about
3–19 mm in diameter in shallow beds about 10–65 mm thick (T1, M1). For very fine particles of 10–200
mesh (1.66–0.079 mm) and bed depth greater than 11 mm, the interfacial area a varies with the
moisture content. Empirical expressions are available for estimating a and the mass-transfer coefficient
(T1, A1).

EXAMPLE 9.10-1. Through-Circulation Drying in a Bed
A granular paste material is extruded into cylinders with a diameter of 6.35 mm and length of
25.4 mm. The initial total moisture content Xt1 = 1.0 kg H2O/kg dry solid and the equilibrium

moisture is X* = 0.01. The density of the dry solid is 1602 kg/m3 (100 lbm/ft 3). The cylinders
are packed on a screen to a depth of x1 = 50.8 mm. The bulk density of the dry solid in the bed

is ρS = 641 kg/m3. The inlet air has a humidity H1 = 0.04 kg H2O/kg dry air and a
temperature T1 = 121.1°C. The gas superficial velocity is 0.811 m/s and the gas passes through
the bed. The total critical moisture content is XtC = 0.50. Calculate the total time to dry the
solids to Xt = 0.10 kg H2O/kg dry solid.

S olu t ion: For the solid,
For the gas, T1 = 121.1°C and H1 = 0.04 kg H2O/kg dry air. The wet bulb temperature TW =
47.2°C and HW = 0.074. The solid temperature is at TW if radiation and conduction are
neglected. The density of the entering air at 121.1°C and 1 atm is as follows:

Equation 9.3-7

The mass velocity of the dry air is

Since the inlet H1 = 0.040 and the outlet will be less than 0.074, an approximate average H of
0.05 will be used to calculate the total average mass velocity. The approximate average Gt is

For the packed bed, the void fraction є is calculated as follows for 1 m3 of bed containing solids
plus voids. A total of 641 kg dry solid is present. The density of the dry solid is 1602 kg dry
solid/m3 solid. The volume of the solids in 1 m3 of bed is then 641/1602, or 0.40 m3 solid.
Hence, є = 1 − 0.40 = 0.60. The solid cylinder length h = 0.0254 m. The diameter Dc =
0.00635 m. Substituting into Eq. (9.10-16),

To calculate the diameter Dp of a sphere with the same area as the cylinder using Eq. (9.10-17),

The bed thickness x1 = 50.8 mm = 0.0508 m.

To calculate the heat-transfer coefficient, the Reynolds number is first calculated. Assuming
an approximate average air temperature of 93.3°C, the viscosity of air is μ = 2.15 × 10−5 kg/m
s = 2.15 × 10−5(3600) = 7.74 × 10−2 kg/m · h. The Reynolds number is

Using Eq. (9.10-13),

For TW = 47.2°C, λ W = 2389 kJ/kg, or 2.389 × 106 J/kg (1027 btu/lbm), from steam tables.
The average humid heat, from Eq. (9.3-6), is

To calculate the time of drying for the constant-rate period using Eq. (9.10-11) and G =
2459/3600 = 0.6831 kg/s · m2,
[View full size image]

For the time of drying for the falling-rate period, using Eq. (9.10-12),
[View full size image]

9 .10B. Tr ay Dr ying w ith Var ying Air  C ond itions

For drying in a compartment or tray dryer where the air passes in parallel flow over the surface of the
tray, the air conditions do not remain constant. Heat and material balances similar to those for through
circulation must be made to determine the exit-gas temperature and humidity.
In Fig. 9.10-2 air is shown passing over a tray. It enters having a temperature of T1 and humidity H1 and

leaves at T2 and H2. The spacing between the trays is b m and dry air flow is G kg dry air/s m2 cross-
sectional area. Writing a heat balance over a length dLt of tray for a section 1 m wide,

Equation 9.10-18

Figure 9.10-2. Heat and material balances in a tray dryer.

The heat-transfer equation is

Equation 9.10-19

Rearranging and integrating,

Equation 9.10-20

Defining a log mean temperature difference similar to Eq. (9.10-10) and substituting into Eqs. (9.6-11)
and (9.7-8), we obtain the following. For the constant-rate period,

Equation 9.10-21
For the falling-rate period, an approximate equation is obtained:

Equation 9.10-22

9 .10C . M ate r ial and  He at Balance s for  C ontinu ou s Dr ye r s

1. S imp le hea t  a nd  ma t er ia l b a la nces

In Fig. 9.10-3 a flow diagram is given for a continuous-type dryer where the drying gas flows
countercurrently to the solids flow. The solid enters at a rate of LS kg dry solid/h, having a free moisture
content X1 and a temperature TS1. It leaves at X2 and TS2. The gas enters at a rate G kg dry air/h, having
a humidity H2 kg H2O/kg dry air and a temperature of TG2. The gas leaves at TG1 and H1.

Figure 9.10-3. Process flow for a counter-current continuous dryer.

For a material balance on the moisture,

Equation 9.10-23

For a heat balance a datum of T0°C is selected. A convenient temperature is 0°C (32°F). The enthalpy of
the wet solid is composed of the enthalpy of the dry solid plus that of the liquid as free moisture. The heat

of wetting is usually neglected. The enthalpy of the gas   in kJ/kg dry air is

Equation 9.10-24

where λ 0 is the latent heat of water at T0°C, 2501 kJ/kg (1075.4 btu/lbm) at 0°C, and cS is the humid
heat, given as kJ/kg dry air · K:
Equation 9.3-6

The enthalpy of the wet solid   in kJ/kg dry solid, where (TS – T0)°C = (TS – T0) K, is

Equation 9.10-25

where cpS is the heat capacity of the dry solid in kJ/kg dry solid · K and cpA is the heat capacity of liquid
moisture in kJ/kg H2O · K. The heat of wetting or adsorption is neglected.

A heat balance on the dryer is

Equation 9.10-26

where Q is the heat loss in the dryer in kJ/h. For an adiabatic process Q = 0, and if heat is added, Q is
negative.

EXAMPLE 9.10-2. Heat Balance on a Dryer
A continuous countercurrent dryer is being used to dry 453.6 kg dry solid/h containing 0.04
kg total moisture/kg dry solid to a value of 0.002 kg total moisture/kg dry solid. The granular
solid enters at 26.7°C and is to be discharged at 62.8°C. The dry solid has a heat capacity of
1.465 kJ/kg K, which is assumed constant. Heating air enters at 93.3°C, having a humidity of
0.010 kg H2O/kg dry air, and is to leave at 37.8°C. Calculate the air flow rate and the outlet
humidity, assuming no heat losses in the dryer.

S olu t ion: The flow diagram is given in Fig. 9.10-3. For the solid, LS = 453.6 kg/h dry solid,
cpS = 1.465 kJ/kg dry solid · K, X1 = 0.040 kg H2O/kg dry solid, cpA = 4.187 kJ/kg H2OK, TS1
= 26.7°C, TS2 = 62.8°C, X2 = 0.002. (Note that X values used are Xt values.) For the gas, TG2 =
93.3°C, H2 = 0.010 kg H2O/kg dry air, and TG1 = 37.8°C.

Making a material balance on the moisture using Eq. (9.10-23),

Equation 9.10-27

For the heat balance, the enthalpy of the entering gas at 93.3°C, using 0°C as a datum, is, by
Eq. (9.10-24), ΔT°C = ΔT K and λ 0 = 2501 kJ/kg, from Table A.2-9,

For the exit gas,

For the entering solid, using Eq. (9.10-25),

Substituting into Eq. (9.10-26) for the heat balance with Q = 0 for no heat loss,

Equation 9.10-28

Solving Eqs. (9.10-27) and (9.10-28) simultaneously,

2. Air  r ecir cu la t ion in d r y er s

In many dryers it is desired to control the wet bulb temperature at which the drying of the solid occurs.
Also, since steam costs are often important in heating the drying air, recirculation of the drying air is
sometimes used to reduce costs and control humidity. Part of the moist, hot air leaving the dryer is
recirculated (recycled) and combined with the fresh air. This is shown in Fig. 9.10-4. Fresh air having a
temperature TG1 and humidity H1 is mixed with recirculated air at TG2 and H2 to give air at TG3 and H3.
This mixture is heated to TG4 with H4 = H3. After drying, the air leaves at a lower temperature TG2 and a
higher humidity H2.

Figure 9.10-4. Process flow for air recirculation in drying.
The following material balances on the water can be made. For a water balance on the heater, noting that
H6 = H5 = H2,

Equation 9.10-29

Making a water balance on the dryer,

Equation 9.10-30

In a similar manner heat balances can be made on the heater and dryer and on the overall system.

9 .10D. C ontinu ou s C ou nte r cu r r e nt Dr ying

1. Int r od u ct ion a nd  t emp er a t u r e p r ofiles

Drying continuously offers a number of advantages over batch-drying. Smaller sizes of equipment can
often be used, and the product has a more uniform moisture content. In a continuous dryer the solid is
moved through the dryer while in contact with a moving gas stream that may flow parallel or
countercurrent to the solid. In countercurrent adiabatic operation, the entering hot gas contacts the
leaving solid, which has been dried. In parallel adiabatic operation, the entering hot gas contacts the
entering wet solid.

In Fig. 9.10-5 typical temperature profiles of the gas TG and the solid TS are shown for a continuous
countercurrent dryer. In the preheat zone, the solid is heated up to the wet bulb or adiabatic saturation
temperature. Little evaporation occurs here, and for low-temperature drying this zone is usually ignored.
In the constant-rate zone, I, unbound and surface moisture are evaporated, and the temperature of the
solid remains essentially constant at the adiabatic saturation temperature if heat is transferred by
convection. The rate of drying would be constant here but the gas temperature is changing, as well as the
humidity. The moisture content falls to the critical value XC at the end of this period.

Figure 9.10-5. Temperature profiles for a continuous countercurrent dryer.
In zone II, unsaturated surface and bound moisture are evaporated and the solid is dried to its final value
X2. The humidity of the gas entering zone II is H2 and it rises to HC. The material-balance equation
(9.10-23) may be used to calculate HC as follows:

Equation 9.10-31

where LS is kg dry solid/h and G is kg dry gas/h.

2. Eq u a t ion for  const a nt -r a t e p er iod

The rate of drying in the constant-rate region in zone I would be constant if it were not for the varying gas
conditions. The rate of drying in this section is given by an equation similar to Eq. (9.6-7):

Equation 9.10-32

The time for drying is given by Eq. (9.6-1) using limits between X1 and XC:

Equation 9.10-33

where A/LS is the exposed drying surface m2/kg dry solid. Substituting Eq. (9.10-32) into (9.10-33) and
(G/LS) dH for dX,

Equation 9.10-34
where G = kg dry air/h, LS = kg dry solid/h, and A/LS = m2/kg dry solid. This can be integrated
graphically or numerically.

For the case where TW or HW is constant for adiabatic drying, Eq. (9.10-34) can be integrated:

Equation 9.10-35

The above can be modified by use of a log mean humidity difference:

Equation 9.10-36

Substituting Eq. (9.10-36) into (9.10-35), an alternative equation is obtained:

Equation 9.10-37

From Eq. (9.10-31), HC can be calculated as follows:

Equation 9.10-38

3. Eq u a t ion for  fa lling -r a t e p er iod

For the situation where unsaturated surface drying occurs, HW is constant for adiabatic drying, the rate
of drying is directly dependent upon X as in Eq. (9.7-9), and Eq. (9.10-32) applies:

Equation 9.10-39
Substituting Eq. (9.10-39) into (9.6-1),

Equation 9.10-40

Substituting G dH/LS for dX and (H − H2)G/LS + X2 for X,

Equation 9.10-41

Equation 9.10-42

Again, to calculate HC, Eq. (9.10-38) can be used.

These equations for the two periods can also be derived using the last part of Eq. (9.10-32) and
temperatures instead of humidities.
                             
                                                 
                                             
                                               
     

9.11. FREEZE­DRYING OF BIOLOGICAL MATERIALS

9 .11A. Intr od u ction

Certain foodstuffs, pharmaceuticals, and biological materials, which may not be heated even to moderate
temperatures in ordinary drying, may be freeze-dried. The substance to be dried is usually frozen by
exposure to very cold air. In freeze-drying, the water is removed as a vapor by sublimation from the frozen
material in a vacuum chamber. After the moisture sublimes to a vapor, it is removed by mechanical
vacuum pumps or steam jet ejectors.

As a rule, freeze-drying produces the highest-quality food product obtainable by any drying method. A
prominent factor is the structural rigidity afforded by the frozen substance when sublimation occurs.
This prevents collapse of the remaining porous structure after drying. When water is added later, the
rehydrated product retains much of its original structural form. Freeze-drying of biological and food
materials also has the advantage of little loss of flavor and aroma. The low temperatures involved
minimize the degrading reactions which normally occur in ordinary drying processes. However, freeze-
drying is an expensive form of dehydration for foods because of the slow drying rate and the use of
vacuum.

Since the vapor pressure of ice is very small, freeze-drying requires very low pressures or high vacuum. If
the water were in a pure state, freeze-drying at or near 0°C (273 K) at a pressure of 4580 μm (4.58 mm Hg
abs) could be performed. (See Appendix A.2 for the properties of ice.) However, since the water usually
exists in a solution or a combined state, the material must be cooled below 0°C to keep the water in the
solid phase. Most freeze-drying is done at −10°C (263 K) or lower at pressures of about 2000 μm or less.

9 .11B. De r iv ation of Eq u ations for  Fr e e ze -Dr ying

In the freeze-drying process the original material is composed of a frozen core of material. As the ice
sublimes, the plane of sublimation, which started at the outside surface, recedes, and a porous shell of
material already dried remains. The heat for the latent heat of sublimation of 2838 kJ/kg (1220 btu/lbm)
ice is usually conducted inward through the layer of dried material. In some cases it is also conducted
through the frozen layer from the rear. The vaporized water is transferred through the layer of dried
material. Hence, heat and mass transfer are occurring simultaneously.

In Fig. 9.11-1 a material being freeze-dried is pictured. Heat by conduction, convection, and/or radiation
from the gas phase reaches the dried surface and is then transferred by conduction to the ice layer. In
some cases heat may also be conducted through the frozen material to reach the sublimation front or
plane. The total drying time must be long enough that the final moisture content is below about 5 wt % to
prevent degradation of the final material on storage. The maximum temperatures reached in the dried
food and the frozen food must be low enough to keep degradation to a minimum.

Figure 9.11-1. Heat and mass tr ansfer in fr eeze drying.


The most widely used freeze-drying process is based upon the heat of sublimation being supplied from
the surrounding gases to the sample surface. Then the heat is transferred by conduction through the
dried material to the ice surface. A simplified model by Sandall et al. (S1) is shown in Fig. 9.11-2.

Figure 9.11-2. Model for uniformly retreating ice front in freeze drying.

The heat flux to the surface of the material in Fig. 9.11-2 occurs by convection and in the dry solid by
conduction to the sublimation surface. The heat flux to the surface is equal to that conducted through the
dry solid, assuming pseudo-steady state:

Equation 9.11-1

where q is heat flux in W (J/s), h is external heat-transfer coefficient in W/m2 · K, Te is external
temperature of the gas in °C, Ts is surface temperature of the dry solid in °C, Tf is temperature of the
sublimation front or ice layer in °C, k is thermal conductivity of the dry solid in W/m · K, and ΔL is the
thickness of the dry layer in m. Note that (Ts − Tf)°C = (Ts − Tf) K.

In a similar manner, the mass flux of the water vapor from the sublimation front is

Equation 9.11-2
where NA is flux of water vapor in kg mol/s · m2, kg is external mass-transfer coefficient in kg mol/s · m2 ·
atm, psw  is partial pressure of water vapor at the surface in atm, pew  is partial pressure of water vapor in
the external bulk gas phase in atm, T is the average temperature in the dry layer, D' is an average effective
diffusivity in the dry layer in m2/s, and pfw  is the partial pressure of water vapor in equilibrium with the
sublimation ice front in atm.

Equation (9.11-1) can be rearranged to give

Equation 9.11-3

Also, Eq. (9.11-2) can be rearranged to give

Equation 9.11-4

The coefficients h and kg are determined by the gas velocities and characteristics of the dryer and hence
are constant. The values of Te and pew  are set by the external operating conditions. The values of k and D'
are determined by the nature of the dried material.

The heat flux and mass flux at pseudo-steady state are related by

Equation 9.11-5

where ΔHs is the latent heat of sublimation of ice in J/kg mol. Also, pfw  is uniquely determined by Tf,
since it is the equilibrium vapor pressure of ice at that temperature; or

Equation 9.11-6

Substituting Eqs. (9.11-3) and (9.11-4) into (9.11-5),

Equation 9.11-7
Also, substituting Eqs. (9.11-1) and (9.11-4) into (9.11-5),

Equation 9.11-8

As Te and, hence, Ts are raised to increase the rate of drying, two limits may possibly be reached. First,
the outer-surface temperature, Ts cannot be allowed to go too high because of thermal damage. Second,
the temperature Tf must be kept well below the melting point. For the situation where k/ΔL is small
compared to kg and D'/RT ΔL, the outer-surface temperature limit will be encountered first as Ts is
raised. To further increase the drying rate, k must be raised. Hence, the process is considered to be heat-
transfer-controlled. Most commercial freeze-drying processes are heat-transfer-controlled (K1).

In order to solve the given equations, ΔL is related to x, the fraction of the original free moisture
remaining:

Equation 9.11-9

The rate of freeze-drying can be related to NA by

Equation 9.11-10

where MA is molecular weight of water, VS is the volume of solid material occupied by a unit kg of water
initially (VS = 1/X0ρS), X0 is initial free moisture content in kg H2O/kg dry solid, and ρS is bulk density

of dry solid in kg/m3.

Combining Eqs. (9.11-3), (9.11-5), (9.11-9), and (9.11-10), we obtain, for heat transfer,

Equation 9.11-11

Similarly, for mass transfer,
Equation 9.11-12

Integrating Eq. (9.11-11) between the limits of t = 0 at x1 = 1.0 and t = t at x2 = x2, the equation for the
time of drying to x2 is as follows for h being very large (negligible external resistance):

Equation 9.11-13

where ΔHs/MA is heat of sublimation in J/kg H2O. For x2 = 0, the slab is completely dry.

Assuming that the physical properties and mass- and heat-transfer coefficients are known, Eq. (9.11-8)
can be used to calculate the ice-sublimation temperature Tf when the environment temperature Te and
the environment partial pressure pew  are set. Since h is very large, Te ≅ Ts. Then Eq. (9.11-8) can be
solved for Tf, since Tf and pfw  are related by the equilibrium-vapor-pressure relation, Eq. (9.11-6). In Eq.
(9.11-8) the value to use for T can be approximated by (Tf + Ts)/2.

The uniformly retreating ice-front model was tested by Sandall et al. (S1) against actual freeze-drying
data. The model satisfactorily predicted the drying times for removal of 65–90% of the total initial water
(S1, K1). The temperature Tf of the sublimation interface did remain essentially constant as assumed in
the derivation. However, during removal of the last 10–35% of the water, the drying rate slowed
markedly and the actual time was considerably greater than the predicted time for this period.

The effective thermal conductivity k in the dried material has been found to vary significantly with the
total pressure and with the type of gas present. Also, the type of material affects the value of k (S1, K1).
The effective diffusivity D' of the dried material is a function of the structure of the material, Knudsen
diffusivity, and molecular diffusivity (K1).
                             
                                                 
                                             
                                               
     

9.12. UNSTEADY­STATE THERMAL PROCESSING AND
STERILIZATION OF BIOLOGICAL MATERIALS

9 .12A. Intr od u ction

Materials of biological origin are usually not as stable as most inorganic and some organic materials.
Hence, it is necessary to use certain processing methods to preserve biological materials, especially foods.
Physical and chemical processing methods of preservation, such as drying, smoking, salting, chilling,
freezing, and heating, are commonly used. Freezing and chilling of foods were discussed in Section 5.5 as
methods of slowing the spoilage of biological materials. Also, in Section 9.11, freeze-drying of biological
materials was discussed.

An important method is heat or thermal processing, whereby contaminating microorganisms that occur
primarily on the outer surface of foods and cause spoilage and health problems are destroyed. This leads
to longer storage times for food and other biological materials. A common method of preservation is to
heat-seal cans of food. Likewise, thermal processing is used to sterilize aqueous fermentation media to be
used in fermentation processes so that organisms that do not survive are unable to compete with the
organism that is to be cultured.

The sterilization of food materials by heating destroys bacteria, yeast, molds, and so on, which cause
spoilage, and also destroys pathogenic (disease-producing) organisms that may produce deadly toxins if
not destroyed. The rate of destruction of microorganisms varies with the amount of heating and the type
of organism. Some bacteria can exist in a vegetative growing form and in a dormant or spore form. The
spore forms are much more resistant to heat. This mechanism of heat resistance is not clear.

For foods, it is necessary to kill essentially all the spores of Clostridium botulinum, which produces a
toxin that is a deadly poison. Complete sterility with respect to this spore is the purpose of thermal
processing. Since Cl. botulinum is so dangerous and often difficult to use, other spores, such as Bacillus
stearothermophilus, which is a nonpathogenic organism of similar heat resistance, are often used for
testing the heat-treating processes (A2, C1).

Temperature has a great effect on the growth rate of microorganisms, which have no temperature-
regulating mechanism. Each organism has a certain optimal temperature range in which it grows best. If
any microorganism is heated to a sufficiently high temperature for a sufficient time, it will be rendered
sterile or killed.

The exact mechanism of thermal death of vegetative bacteria and spores is still somewhat uncertain. It is
thought, however, to be due to the breakdown of enzymes, which are essential to the functioning of the
living cell (B1).

9 .12B. The r m al De ath-R ate  K ine tics of M icr oor ganism s

The destruction of microorganisms by heating means loss of viability and not destruction in the physical
sense. If it is assumed that inactivation of a single enzyme in a cell will inactivate the cell, then in a
suspension of organisms of a single species at a constant temperature, the death rate can be expressed as
a first-order kinetic equation (A2). The rate of destruction (number dying per unit time) is proportional to
the number of organisms:

Equation 9.12-1

where N is the number of viable organisms at a given time, t is time in min, and k is a reaction velocity
constant in min–1. The reaction velocity constant is a function of temperature and the type of
microorganism.

After rearranging, Eq. (9.12-1) can be integrated as follows:

Equation 9.12-2

Equation 9.12-3

where N0 is the original number of organisms at t = 0 and N is the number at time t. Often N0 is called
the contamination level (original number of contaminating microbes before sterilization) and N the
sterility level. Equation (9.12-3) can also be written as

Equation 9.12-4

Sometimes microbiologists use the term decimal reduction time D, which is the time in min during

which the original number of viable microbes is reduced by  . Substituting into Eq. (9.12-4),

Equation 9.12-5

Taking the log10 of both sides and solving for D,

Equation 9.12-6
Combining Eqs. (9.12-3) and (9.12-6),

Equation 9.12-7

If the log10(N/N0) is plotted versus t, a straight line should result from Eq. (9.12-3). Experimental data
bear this out for vegetative cells and approximately for spores. Data for the vegetative cell E. coli (A1) at
constant temperature follow this logarithmic death-rate curve. Bacterial-spore plots sometimes deviate
somewhat from the logarithmic rate of death, particularly during a short period immediately following
exposure to heat. However, for thermal-processing purposes for use with spores such as Cl. botulinum, a
logarithmic-type curve is used.

To experimentally measure the microbial death rate, the spore or cell suspension in a solution is usually
sealed in a capillary or test tube. A number of these tubes are then suddenly dipped into a hot bath for a
given time. Then they are removed and immediately chilled. The number of viable organisms before and
after exposure to the high temperature is then usually determined biologically by means of a plate count.

The effect of temperature on the reaction-rate constant k may be expressed by an Arrhenius-type
equation:

Equation 9.12-8

where a = an empirical constant, R is the gas constant in kJ/g mol · K (cal/gmol · K), T is absolute
temperature in K, and E is the activation energy in kJ/g mol (cal/g mol). The value of E is in the range
210 to about 418 kJ/g mol (50–100 kcal/g mol) for vegetative cells and spores (A2) and much lower for
enzymes and vitamins.

Substituting Eq. (9.12-8) into (9.12-2) and integrating,

Equation 9.12-9

At constant temperature T, Eq. (9.12-9) becomes (9.12-3). Since k is a function of temperature, the
decimal reduction time D, which is related to k by Eq. (9.12-6), is also a function of temperature. Hence,
D is often written as DT to show that it is temperature-dependent.

9 .12C . De te r m ination of The r m al Pr oce ss Tim e  for  S te r ilization


For canned foods, Cl. botulinum is the primary organism to be reduced in number (S2). It has been
established that the minimum adequate heating process should reduce the number of spores by a factor
of 10−12. This means that, since D is the time required to reduce the original number by 10−1, substituting
N/N0 = 10−12 into Eq. (9.12-4) and solving for t,

Equation 9.12-10

Thus the time t is equal to 12D (often called the 12D concept). This time in Eq. (9.12-10) to reduce the
number by 10−12 is called the thermal death time. Usually, the sterility level N is a number much less
than one organism. These times do not represent complete sterilization but a mathematical concept
which has been found empirically to give effective sterilization.

Experimental data for thermal death rates of Cl. botulinum, when plotted as the decimal reduction time
DT at a given T versus the temperature T in °F on a semilog plot, give essentially straight lines over the
range of temperatures used in food sterilization (S2). A typical thermal destruction curve is shown in Fig.
9.12-1. Actually, by combining Eqs. (9.12-6) and (9.12-8), it can be shown that the plot of log10DT versus
1/T (T in degrees absolute) is a straight line, but over small ranges of temperature a straight line is
obtained when log10 DT is plotted versus T°F or °C.

Figure 9.12-1. Thermal destruction curve: plot of decimal reduction time versus temperature.

In Fig. 9.12-1 the term z represents the temperature range in °F for a 10:1 change in DT. Since the plot is a
straight line, the equation can be represented as

Equation 9.12-11
Letting T1 = 250°F (121.1°C), which is the standard temperature against which thermal processes are
compared, and calling T2 = T, Eq. (9.12-11) becomes

Equation 9.12-12

For the organism Cl. botulinum the experimental value of z = 18°F. This means that each increase in
temperature of 18°F (10°C) will increase the death rate by a factor of 10. This compares with the factor of
2 for many chemical reactions for an 18°F increase in temperature.

Using Eq. (9.12-7),

Equation 9.12-7

Substituting T = 250°F (121.1°C) as the standard temperature into this equation and substituting F0 for
t,

Equation 9.12-13

where the F0 value of a process is the time t in min at 250°F that will produce the same degree of
sterilization as the given process at its temperature T. Combining Eqs. (9.12-7), (9.12-12), and (9.12-13),
the F0 of the given process at temperature T is

Equation 9.12-14

This is the F0 value in min for the given thermal process at a given constant temperature T°F and a given
time t in min. Values for F0 and z for adequate sterilization of Cl. botulinum vary somewhat with the
type of food. Data are tabulated by Stumbo (S2) and Charm (C2) for various foods and microorganisms.

The effects of different but successive sterilization processes in a given material are additive. Hence, for
several different temperature stages T1, T2, and so on, each having different times t 1, t 2, . . . , the F0
values for each stage are added to give the total F0:

Equation 9.12-15
EXAMPLE 9.12-1. Sterilization of Cans of Food
Cans of a given food were heated in a retort for sterilization. The F0 for Cl. botulinum in this
type of food is 2.50 min and z = 18°F. The temperatures in the center of a can (the slowest-
heating region) were measured and were approximately as follows, where the average
temperature during each time period is listed: t 1 (0–20 min), T1 = 160°F; t 2 (20–40 min), T2 =
210°F; t 3 (40–73 min), T3 = 230°F. Determine if this sterilization process is adequate. Use
English and SI units.

S olu t ion: For the three time periods, the data are as follows:

Substituting into Eq. (9.12-15) and solving, using English and SI units,

Equation 9.12-15

Hence, this thermal processing is adequate, since only 2.50 min is needed for complete
sterilization. Note that the time period at 160°F (71.1°C) contributes an insignificant amount
to the final F0. The major contribution is at 230°F (110°C), which is the highest temperature.

In the general case when cans of food are being sterilized in a retort, the temperature is not constant for a
given time period but varies continuously with time. Hence, Eq. (9.12-15) can be modified and written for
a continuously varying temperature T by taking small time increments of dt min for each value of T and
summing. The final equation is

Equation 9.12-16
This equation can be used as follows. Suppose that the temperature of a process is varying continuously
and that a graph or table of values of T versus t is known or can be calculated by means of the unsteady-
state methods given in Chapter 5. Equation (9.12-16) can be graphically integrated by plotting values of
10(T−250)/z versus t and taking the area under the curve. In most cases a numerical integration is used to
determine F0. (See Section 1.8 for methods of numerical integration.)

In many cases the temperature of a process that is varying continuously with time is determined
experimentally by measuring the temperature in the slowest-heating region. In cans this is the center of
the can. Methods given in Chapter 5 for unsteady-state heating of short, fat cylinders by conduction can
be used to predict the center temperature of the can as a function of time. However, these predictions can
be somewhat in error, since physical and thermal properties of foods are difficult to measure accurately
and often can vary. Also, trapped air in the container and unknown convection effects can affect the
accuracy of predictions.

EXAMPLE 9.12-2. Thermal Process Evaluation by
Numerical Integration
In the sterilization of a canned purée, the temperature in the slowest-heating region (center) of
the can was measured, giving the following time–temperature data for the heating and
holding time. The cooling-time data will be neglected as a safety factor.

t (min) T (°F) t (min) T (°F)

0 80 (26.7°C) 40 225 (107.2°C)

15 165 (73.9) 50 230.5 (110.3)


25 201 (93.9) 64 235 (112.8)
30 212.5 (100.3)    

The F0 value of Cl. botulinum is 2.45 min and z is 18°F. Calculate the F0 value of the process
above and determine if the sterilization is adequate.

S olu t ion: In order to use Eq. (9.12-16), the values of 10(T−250)/z must be calculated for each
time. For t = 0 min, T = 80°F, and z = 18°F,

For t = 15 min, T = 165°F,      
  10(165 − 250)/18 = 0.0000189

For t = 25 min, T = 201°F,      

  10(201 − 250)/18 = 0.00189
For t = 30 min,      
  10(201 − 250)/18 = 0.00825

For t = 40 min,      
  10(225 − 250)/18 = 0.0408

For t = 50 min,      

  10(230.5 − 250)/18 = 0.0825

For t = 64 min,      

  10(235 − 250)/18 = 0.1465

These calculated values are then used in Eq. (9.12-16) to perform a numerical integration to
give F0 = 2.50 min. The process value of 2.50 min is greater than the required value of 2.45
min, and the sterilization is adequate.

9 .12D. S te r ilization M e thod s Using Othe r  De sign C r ite r ia

In types of thermal processing which are not necessarily involved with sterilization of foods, other types
of design criteria are used. In foods the minimum adequate heat process should reduce the number of
spores by a factor of 10−12, that is, N/N0 = 10−12. However, in other batch-sterilization processes, such as
in the sterilization of fermentation media, other criteria are often used. Often the equation for k, the
reaction velocity constant for the specific organism to be used, is available:

Equation 9.12-8

Then Eq. (9.12-9) is written as

Equation 9.12-17

where ∇ is the design criterion. Usually, the contamination level N0 is available and either the sterility
level N or the time of sterilization at a given temperature is the unknown. In either case a numerical or
graphical integration is used to solve the problem.

In sterilization of food in a container, the time required to render the material safe is calculated at the
slowest-heating region of the container (usually the center). Other regions of the container are usually
heated to higher temperatures and are overtreated. Hence, another method used is based on the
probability of survival in the whole container. These details are given by others (C2, S2). In still another
processing method, a short-time, continuous-flow process is used instead of a batch process in a
container (B2).
9 .12E. Paste u r ization

The term pasteurization is used today to apply to a mild heat treatment of foods that is less drastic than
sterilization. It is used to kill organisms that are relatively low in thermal resistance compared to those
which the more drastic sterilization processes are designed to eliminate. Pasteurization usually involves
killing vegetative microorganisms and not heat-resistant spores.

The most common process is the pasteurization of milk to kill Mycobacterium tuberculosis, which is a
non-spore-forming bacterium. This pasteurization does not sterilize the milk but kills the M. tuberculosis
and reduces the other bacterial count sufficiently so that the milk can be stored if refrigerated.

For the pasteurization of such foods as milk, fruit juices, and beer, the same mathematical and numerical
procedures covered for sterilization processes in this section are used to accomplish the degree of
sterilization desired in pasteurization (B1, S2). The times involved are much shorter and the
temperatures used in pasteurization are much lower. Generally, the F0 value is given as 150°F (65.6°C)
or a similar temperature rather than 250°F as in sterilization. Also, the concept of the z value is
employed, in which a rise in temperature of z°F will increase the death rate by a factor of 10. An F0 value

written as   means the F value at 150°F with a z value of 9°F (S2).

In pasteurizing milk, batch and continuous processes are used. U.S. health regulations specify two
equivalent sets of conditions; in one, the milk is held at 145°F (62.8°C) for 30 min, and in the other, at
161°F (71.7°C) for 15 s.

The general equations used for pasteurization are similar to sterilization and can be written as follows.
Rewriting Eq. (9.12-13),

Equation 9.12-18

Rewriting Eq. (9.12-14),

Equation 9.12-19

where T1 is the standard temperature being used, such as 150°F, z is the value of z in °F for a tenfold
increase in death rate, and T is the temperature of the actual process.

EXAMPLE 9.12-3. Pasteurization of Milk

A typical F value given for the thermal processing of milk in a tubular heat exchanger is   =
9.0 min, and D150 = 0.6 min. Calculate the reduction in the number of viable cells under these
conditions.
S olu t ion: The z value is 9°F (5°C) and the temperature of the process is 150°F (65.6°C).
Substituting into Eq. (9.12-18) and solving,

This gives a reduction in the number of viable cells of 1015.

9 .12F. Effe cts of The r m al Pr oce ssing on Food  C onstitu e nts

Thermal processing is used to cause the death of various undesirable microorganisms, but it also causes
undesirable effects, such as the reduction of certain nutritional values. Ascorbic acid (vitamin C) and
thiamin and riboflavin (vitamins B1 and B2) are partially destroyed by thermal processing. The reduction
of these desirable constituents can also be given kinetic parameters such as F0 and z values in the same
way as for sterilization and pasteurization. Examples and data are given by Charm (C2).

These same kinetic methods of thermal death rates can also be applied to predict the time for detecting a
flavor change in a food product. Dietrich et al. (D1) determined a curve for the number of days to detect a
flavor change in frozen spinach versus temperature of storage. The data followed Eq. (9.12-8) and a first-
order kinetic relation.
                             
                                                 
                                             
                                               
     

PROBLEMS
9 .3-1.
Hu mid it y  fr om Va p or  Pr essu r e. The air in a room is at 37.8°C and a total pressure of 101.3
kPa abs containing water vapor with a partial pressure pA = 3.59 kPa. Calculate:

a.  Humidity.

b.  Saturation humidity and percentage humidity.

c.  Percentage relative humidity.

9 .3-2.
Per cent a g e a nd  R ela t iv e Hu mid it y . The air in a room has a humidity H of 0.021 kg
H2O/kg dry air at 32.2°C and 101.3 kPa abs pressure. Calculate:

a.  Percentage humidity HP.

b.  Percentage relative humidity HR.

A2:Ans. (a) HP = 67.5%; (b) HR = 68.6%
9 .3-3.
Use of t he  Hu mid it y  C ha r t . The air entering a dryer has a temperature of 65.6°C (150°F) and
dew point of 15.6°C (60°F). Using the humidity chart, determine the actual humidity and
percentage humidity. Calculate the humid volume of this mixture and also calculate cS using SI
and English units.
A3:Ans. H = 0.0113 kg H2O/kg dry air, HP = 5.3%, cS = 1.026 kJ/kg · K (0.245 btu/lbm · °F), νH =
0.976 m3 air + water vapor/kg dry air
9 .3-4 .
Pr op er t ies of Air  t o a  Dr y er . An air–water vapor mixture going to a drying process has a dry
bulb temperature of 57.2°C and a humidity of 0.030 kg H2O/kg dry air. Using the humidity
chart and appropriate equations, determine the percentage humidity, saturation humidity at
57.2°C, dew point, humid heat, and humid volume.
9 .3-5.
Ad ia b a t ic S a t u r a t ion Temp er a t u r e. Air at 82.2°C having a humidity H = 0.0655 kg
H2O/kg dry air is contacted in an adiabatic saturator with water. It leaves at 80% saturation.

a.  What are the final values of H and T°C?

b.  For 100% saturation, what would be the values of H and T?

A5:Ans. (a) H = 0.079 kg H2O/kg dry air, T = 52.8°C

9 .3-6 .
Ad ia b a t ic S a t u r a t ion of Air . Air enters an adiabatic saturator having a temperature of
76.7°C and a dew-point temperature of 40.6°C. It leaves the saturator 90% saturated. What are
the final values of H and T°C?
9 .3-7.Hu mid it y  fr om W et  a nd  Dr y  Bu lb  Temp er a t u r es. An air–water vapor mixture has a dry
bulb temperature of 65.6°C and a wet bulb temperature of 32.2°C. What is the humidity of the
mixture?

A7:Ans. H = 0.0175 kg H2O/kg dry air
9 .3-8.
Hu mid it y  a nd  W et  Bu lb  Temp er a t u r e. The humidity of an air–water vapor mixture is H =
0.030 kg H2O/kg dry air. The dry bulb temperature of the mixture is 60°C. What is the wet bulb
temperature?
9 .3-9 .
Dehu mid ifica t ion of Air . Air having a dry bulb temperature of 37.8°C and a wet bulb
temperature of 26.7°C is to be dried by first cooling to 15.6°C to condense water vapor and then
heating to 23.9°C.

a.  Calculate the initial humidity and percentage humidity.

b.  Calculate the final humidity and percentage humidity. [Hint: Locate the initial point on
the humidity chart. Then go horizontally (cooling) to the 100% saturation line. Follow
this line to 15.6°C. Then go horizontally to the right to 23.9°C.]

A9 :Ans. (b) H = 0.0115 kg H2O/kg dry air, HP = 60%
9 .3-10.
C ooling  a nd  Dehu mid ify ing  Air . Air entering an adiabatic cooling chamber has a
temperature of 32.2°C and a percentage humidity of 65%. It is cooled by a cold water spray and
saturated with water vapor in the chamber. After leaving, it is heated to 23.9°C. The final air has
a percentage humidity of 40%.

a.  What is the initial humidity of the air?

b.  What is the final humidity after heating?

9 .6 -1.
Time for  Dr y ing  in C onst a nt -R a t e Per iod . A batch of wet solid was dried on a tray dryer
using constant drying conditions and a thickness of material on the tray of 25.4 mm. Only the
top surface was exposed. The drying rate during the constant-rate period was R = 2.05 kg H2O/h

· m2 (0.42 lbm H2O/h · ft 2). The ratio LS/A used was 24.4 kg dry solid/m2 exposed surface (5.0

lbm dry solid/ft 2). The initial free moisture was X1 = 0.55 and the critical moisture content XC =
0.22 kg free moisture/kg dry solid.
Calculate the time to dry a batch of this material from X1 = 0.45 to X2 = 0.30 using the same
drying conditions but a thickness of 50.8 mm, with drying from the top and bottom surfaces.
(Hint: First calculate LS/A for this new case.)
A11:Ans. t = 1.785 h
9 .6 -2.
Pr ed ict ion of Effect  of Pr ocess Va r ia b les on Dr y ing  R a t e. Using the conditions in
Example 9.6-3 for the constant-rate drying period, do as follows:

a.  Predict the effect on RC if the air velocity is only 3.05 m/s.

b.  Predict the effect if the gas temperature is raised to 76.7°C and H remains the same.

c.  Predict the effect on the time t for drying between moisture contents X1 to X2 if the
thickness of material dried is 38.1 mm instead of 25.4 mm and the drying is still in the
constant-rate period.

A12: Ans.  (a) R  = 1.947 kg H O/h · m2 (0.399 lb  H O/h · ft 2); (b) R  = 4.21 kg H O/h · m2


C 2 m 2 C 2
9 .6 -3.
Pr ed ict ion in C onst a nt -R a t e Dr y ing  R eg ion. A granular insoluble solid material wet with
water is being dried in the constant-rate period in a pan 0.61 m × 0.61 m and the depth of
material is 25.4 mm. The sides and bottom are insulated. Air flows parallel to the top drying
surface at a velocity of 3.05 m/s and has a dry bulb temperature of 60°C and wet bulb
temperature of 29.4°C. The pan contains 11.34 kg of dry solid having a free moisture content of
0.35 kg H2O/kg dry solid, and the material is to be dried in the constant-rate period to 0.22 kg
H2O/kg dry solid.

a.  Predict the drying rate and the time in hours needed.

b.  Predict the time needed if the depth of material is increased to 44.5 mm.

9 .6 -4 .
Dr y ing  a  Filt er  C a k e in t he C onst a nt -R a t e R eg ion. A wet filter cake in a pan 1 ft × 1 ft
square and 1 in. thick is dried on the top surface with air at a wet bulb temperature of 80°F and a
dry bulb temperature of 120°F flowing parallel to the surface at a velocity of 2.5 ft/s. The dry
density of the cake is 120 lbm/ft 3 and the critical free moisture content is 0.09 lb H2O/lb dry
solid. How long will it take to dry the material from a free moisture content of 0.20 lb H2O/lb dry
material to the critical moisture content?
A14 :Ans. t = 13.3 h
9 .7-1.
Nu mer ica l Int eg r a t ion for  Dr y ing  in Fa lling -R a t e R eg ion. A wet solid is to be dried in a
tray dryer under steady-state conditions from a free moisture content of X1 = 0.40 kg H2O/kg
dry solid to X2 = 0.02 kg H2O/kg dry solid. The dry solid weight is 99.8 kg dry solid and the top

surface area for drying is 4.645 m2. The drying-rate curve can be represented by Fig. 9.5-1b.

a.  Calculate the time for drying using numerical integration in the falling-rate period.

b.  Repeat but use a straight line through the origin for the drying rate in the falling-rate
period.

A15:Ans. (a) t(constant rate) = 2.91 h, t(falling rate) = 6.65 h, t(total) = 9.56 h
9 .7-2.
Dr y ing  Test s w it h a  Food st u ff. In order to test the feasibility of drying a certain foodstuff,
drying data were obtained in a tray dryer with air flow over the top exposed surface having an
area of 0.186 m2. The bone-dry sample weight was 3.765 kg dry solid. At equilibrium after a long
period, the wet sample weight was 3.955 kg H2O + solid. Hence, 3.955 − 3.765, or 0.190, kg of
equilibrium moisture was present. The following sample weights versus time were obtained in
the drying test:

Time (h) Weight (kg) Time (h) Weight (kg) Time (h) Weight (kg)

0 4.944 2.2 4.554 7.0 4.019

0.4 4.885 3.0 4.404 9.0 3.978


0.8 4.808 4.2 4.241 12.0 3.955
1.4 4.699 5.0 4.150    

a.  Calculate the free moisture content X kg H2O/kg dry solid for each data point and plot X
versus time. (Hint: For 0 h, 4.944 − 0.190 − 3.765 = 0.989 kg free moisture in 3.765 kg
dry solid. Hence, X = 0.989/3.765.)

b.  Measure the slopes, calculate the drying rates R in kg H2O/h · m2, and plot R versus X.

c.  Using this drying-rate curve, predict the total time to dry the sample from X = 0.20 to X =
0.04. Use numerical integration for the falling-rate period. What are the drying rate RC in
the constant-rate period and XC?

A16 : Ans.  (c) R  = 0.996 kg H O/h · m2, X  = 0.12, t  = 4.1 h (total)


C 2 C
9 .7-3.
Pr ed ict ion of Dr y ing  Time. A material was dried in a tray-type batch dryer using constant-
drying conditions. When the initial free moisture content was 0.28 kg free moisture/kg dry solid,
6.0 h was required to dry the material to a free moisture content of 0.08 kg free moisture/kg dry
solid. The critical free moisture content is 0.14. Assuming a drying rate in the falling-rate region,
where the rate is a straight line from the critical point to the origin, predict the time to dry a
sample from a free moisture content of 0.33 to 0.04 kg free moisture/kg dry solid. (Hint: First
use the analytical equations for the constant-rate and the linear falling-rate periods with the
known total time of 6.0 h. Then use the same equations for the new conditions.)
9 .8-1.
Dr y ing  of Biolog ica l M a t er ia l in Tr a y  Dr y er . A granular biological material wet with
water is being dried in a pan 0.305 × 0.305 m and 38.1 mm deep. The material is 38.1 mm deep
in the pan, which is insulated on the sides and bottom. Heat transfer is by convection from an
air stream flowing parallel to the top surface at a velocity of 3.05 m/s, having a temperature of
65.6°C and humidity H = 0.010 kg H2O/kg dry air. The top surface receives radiation from
steam-heated pipes whose surface temperature TR = 93.3°C. The emissivity of the solid is є =
0.95. It is desired to keep the surface temperature of the solid below 32.2°C so that
decomposition will be kept low. Calculate the surface temperature and the rate of drying for the
constant-rate period.
A18: Ans.  T  = 31.3°C, R  = 2.583 kg H O/hm2
S C 2
9 .8-2.
Dr y ing  W hen R a d ia t ion, C ond u ct ion, a nd  C onv ect ion Ar e Pr esent . A material is
granular and wet with water and is being dried in a layer 25.4 mm deep in a batch-tray dryer
pan. The pan has a metal bottom having a thermal conductivity of kM = 43.3 W/m · K and a
thickness of 1.59 mm. The thermal conductivity of the solid is kS = 1.125 W/m · K. The air flows
parallel to the top exposed surface and the bottom metal at a velocity of 3.05 m/s and a
temperature of 60°C and humidity H = 0.010 kg H2O/kg dry solid. Direct radiation heat from
steam pipes having a surface temperature of 104.4°C falls on the exposed top surface, whose
emissivity is 0.94. Estimate the surface temperature and the drying rate for the constant-rate
period.
9 .9 -1.
Diffu sion Dr y ing  in W ood . Repeat Example 9.9-1 using the physical properties given but
with the following changes:
a.  Calculate the time needed to dry the wood from a total moisture of 0.22 to 0.13. Use Fig.
5.3-13.

b.  Calculate the time needed to dry planks of wood 12.7 mm thick from Xt1 = 0.29 to Xt =
0.09. Compare with the time needed for 25.4 mm thickness.

A20:Ans. (b) t = 7.60 h (12.7 mm thick)
9 .9 -2.
Diffu siv it y  in Dr y ing  Ta p ioca  R oot . Using the data given in Example 9.9-2, determine the
average diffusivity of the moisture up to a value of X/XC = 0.50.
9 .9 -3.
Diffu sion C oefficient . Experimental drying data for a typical nonporous biological material
obtained under constant drying conditions in the falling-rate region are tabulated below.

X/XC t(h) X/XC t(h)

1.00 0 0.17 11.4

0.65 2.50 0.10 14.0


0.32 7.00 0.06 16.0

Drying from one side occurs, with the material having a thickness of 10.1 mm. The data appear
to follow the diffusion equation. Determine the average diffusivity over the range X/XC = 1.0–
0.10.
9 .10-1.
Dr y ing  a  Bed  of S olid s b y  Thr ou g h C ir cu la t ion. Repeat Example 9.10-1 for drying of a
packed bed of wet cylinders by through circulation of the drying air. Use the same conditions
except that the air velocity is 0.381 m/s.
9 .10-2.
Der iv a t ion of Eq u a t ion for  Thr ou g h-C ir cu la t ion Dr y ing . Different forms of Eqs. (9.10-
11) and (9.10-12) can be derived using humidity and mass-transfer equations rather than
temperature and heat-transfer equations. This can be done by writing a mass-balance equation
similar to Eq. (9.10-2) for a heat balance and a mass-transfer equation similar to Eq. (9.10-3).

a.  Derive the final equation for the time of drying in the constant-rate period using humidity
and mass-transfer equations.

b.  Repeat for the falling-rate period.

A24 :  

Ans.
9 .10-3.
Thr ou g h-C ir cu la t ion Dr y ing  in t he C onst a nt -R a t e Per iod . Spherical wet catalyst
pellets having a diameter of 12.7 mm are being dried in a through-circulation dryer. The pellets
are in a bed 63.5 mm thick on a screen. The solids are being dried by air entering with a
superficial velocity of 0.914 m/s at 82.2°C and having a humidity H = 0.01 kg H2O/kg dry air.

The dry solid density is determined as 1522 kg/m3, and the void fraction in the bed is 0.35. The
initial free moisture content is 0.90 kg H2O/kg solid and the solids are to be dried to a free
moisture content of 0.45, which is above the critical free moisture content. Calculate the time for
drying in this constant-rate period.
9 .10-4 .
M a t er ia l a nd  Hea t  Ba la nces on a  C ont inu ou s Dr y er . Repeat Example 9.10-2, making
heat and material balances, but with the following changes. The solid enters at 15.6°C and
leaves at 60°C. The gas enters at 87.8°C and leaves at 32.2°C. Heat losses from the dryer are
estimated as 2931 W.
9 .10-5.
Dr y ing  in a  C ont inu ou s Tu nnel Dr y er . A rate of feed of 700 lbm dry solid/h containing a
free moisture content of X1 = 0.4133 lb H2O/lb dry solid is to be dried to X2 = 0.0374 lb H2O/lb
dry solid in a continuous-counterflow tunnel dryer. A flow of 13 280 lbm dry air/h enters at
203°F with an H2 = 0.0562 lb H2O/lb dry air. The stock enters at the wet bulb temperature of
119°F and remains essentially constant in temperature in the dryer. The saturation humidity at
119°F from the humidity chart is HW = 0.0786 lb H2O/lb dry air. The surface area available for

drying is (A/LS) = 0.30 ft 2/lbm dry solid.
A small-batch experiment was performed using approximately the same constant-drying
conditions, air velocity, and temperature of the solid as in the continuous dryer. The equilibrium
critical moisture content was found to be XC = 0.0959 lb H2O/lb dry solid, and the experimental
value of k M  was found as 30.15 lb  air/h · ft 2. In the falling-rate period, the drying rate was
y B m
directly proportional to X.

For the continuous dryer, calculate the time in the dryer in the constant-rate zone and the
falling-rate zone.

A27:Ans. HC = 0.0593 lb H2O/lb dry air, H1 = 0.0760 lb H2O/lb dry air, t = 4.20 h in the constant-
rate zone, t = 0.47 h in the falling-rate zone
9 .10-6 .
Air  R ecir cu la t ion in a  C ont inu ou s Dr y er . The wet feed material to a continuous dryer
contains 50 wt % water on a wet basis and is dried to 27 wt % by countercurrent air flow. The
dried product leaves at the rate of 907.2 kg/h. Fresh air to the system is at 25.6°C and has a
humidity of H = 0.007 kg H2O/kg dry air. The moist air leaves the dryer at 37.8°C and H =
0.020 and part of it is recirculated and mixed with the fresh air before entering a heater. The
heated mixed air enters the dryer at 65.6°C and H = 0.010. The solid enters at 26.7°C and leaves
at 26.7°C. Calculate the fresh-air flow, the percent air leaving the dryer that is recycled, the heat
added in the heater, and the heat loss from the dryer.
A28:Ans. 32 094 kg fresh dry air/h, 23.08% recycled, 440.6 kW in heater
9 .12-1.
S t er ilizing  C a nned  Food s. In a sterilizing retort, cans of a given food were heated; the
average temperature in the center of a can is approximately 98.9°C for the first 30 min. The
average temperature for the next period is 110°C. If F0 for the spore organism is 2.50 min and z =
10°C, calculate the time of heating at 110°C to make the process safe.
A29 :Ans. 29.9 min
9 .12-2.
Temp er a t u r e Effect  on Decima l R ed u ct ion Time. Prove by combining Eqs. (9.12-6) and
(9.12-8) that a plot of log10 DT versus 1/T (T in degrees absolute) is a straight line.
9 .12-3.
Ther ma l Pr ocess Time for  Pea  Pu r ée. For cans of pea purée, F0 = 2.45 min and z = 9.94°C
(C2). Neglecting heatup time, determine the process time for adequate sterilization at 112.8°C at
the center of the can.
A31:Ans. t = 16.76 min
9 .12-4 .
Pr ocess Time for  Ad eq u a t e S t er iliza t ion. The F0 value for a given canned food is 2.80 min
and z is 18°F (10°C). The center temperatures of a can of this food when heated in a retort were
as follows for the time periods given: t 1 (0–10 min), T1 = 140°F; t 2 (10–30 min), T2 = 185°F; t 3
(30–50 min), T3 = 220°F; t 4 (50–80 min), T4 = 230°F; t 5 (80–100 min), T5 = 190°F. Determine
if adequate sterilization is obtained.
9 .12-5.
Pr ocess Time a nd  Nu mer ica l Int eg r a t ion. The following time–temperature data were
obtained for the heating, holding, and cooling of a canned food product in a retort, the
temperature being measured in the center of the can:

t(min) T(°F) t(min) T(°F)

0 110 (43.3°C) 80 232 (111.1)
20 165 (73.9) 90 225 (107.2)
40 205 (96.1) 100 160 (71.1)

60 228 (108.9)    

The F0 value used is 2.60 min and z is 18°F (10°C). Calculate the F0 value for this process and
determine if the thermal processing is adequate. Use SI and English units.
9 .12-6 .
S t er ilit y  Lev el of Fer ment a t ion M ed iu m. The aqueous medium in a fermentor is being
sterilized and the time–temperature data obtained are as follows:

Time (min) 0 10 20 25 30 35

Temperature (°C) 100 110 120 120 110 100

The reaction velocity constant k in min−1 for the contaminating bacterial spores can be
represented as (A1)

where T = K. The contamination level N0 = 1 × 1012 spores. Calculate the sterility level N at the
end and ∇.
9 .12-7.
Time for  Pa st eu r iza t ion of M ilk . Calculate the time in min at 62.8°C for pasteurization of
milk. The F0 value to be used at 65.6°C is 9.0 min. The z value is 5°C.
A35:Ans. t = 32.7 min
9 .12-8.
R ed u ct ion in Nu mb er  of Via b le C ells in Pa st eu r iza t ion. In a given pasteurization
process the reduction in the number of viable cells used is 1015 and the F0 value is 9.0 min. If the

reduction is to be increased to 1016 because of increased contamination, what would be the new
F0 value?
Chapter 10. Stage and Continuous Gas–Liquid
Separation Processes
                             
                                                 
                                             
                                               
     

10.1. TYPES OF SEPARATION PROCESSES AND METHODS

10.1A. Intr od u ction

Many chemical process materials and biological substances occur as mixtures of different components in
the gas, liquid, or solid phase. In order to separate or remove one or more of the components from its
original mixture, it must be contacted with another phase. The two phases are brought into more or less
intimate contact with each other so that a solute or solutes can diffuse from one to the other. The two
bulk phases are usually only somewhat miscible in each other. The two-phase pair can be gas–liquid,
gas–solid, liquid–liquid, or liquid–solid. During the contact of the two phases the components of the
original mixture redistribute themselves between the two phases. The phases are then separated by
simple physical methods. By choosing the proper conditions and phases, one phase is enriched while the
other is depleted in one or more components.

10.1B. Typ e s of S e p ar ation Pr oce sse s

1. Ab sor p t ion

When the two contacting phases are a gas and a liquid, this operation is called absorption. A solute A or
several solutes are absorbed from the gas phase into the liquid phase in absorption. This process involves
molecular and turbulent diffusion or mass transfer of solute A through a stagnant, nondiffusing gas B
into a stagnant liquid C. An example is absorption of ammonia A from air B by the liquid water C.
Usually, the exit ammonia–water solution is distilled to recover relatively pure ammonia.

Another example is absorbing SO2 from the flue gases by absorption in alkaline solutions. In the
hydrogenation of edible oils in the food industry, hydrogen gas is bubbled into oil and absorbed. The
hydrogen in solution then reacts with the oil in the presence of a catalyst. The reverse of absorption is
called stripping or desorption, and the same theories and basic principles hold. An example is the steam
stripping of nonvolatile oils, in which the steam contacts the oil and small amounts of volatile
components of the oil pass out with the steam.

When the gas is pure air and the liquid is pure water, the process is called humidification.
Dehumidification involves removal of water vapor from air.

2. Dist illa t ion

In the distillation process, a volatile vapor phase and a liquid phase that vaporizes are involved. An
example is distillation of an ethanol–water solution, where the vapor contains a concentration of ethanol
greater than in the liquid. Another example is distillation of an ammonia–water solution to produce a
vapor richer in ammonia. In the distillation of crude petroleum, various fractions, such as gasoline,
kerosene, and heating oils, are distilled off.

3. Liq u id –liq u id  ext r a ct ion

When the two phases are liquids, where a solute or solutes are removed from one liquid phase to another
liquid phase, the process is called liquid–liquid extraction. One example is extraction of acetic acid from
a water solution by isopropyl ether. In the pharmaceutical industry, antibiotics in an aqueous
fermentation solution are sometimes removed by extraction with an organic solvent.

4 . Lea chi ng

If a fluid is being used to extract a solute from a solid, the process is called leaching. Sometimes this
process is also called extraction. Examples are leaching copper from solid ores by sulfuric acid and
leaching vegetable oils from solid soybeans by organic solvents such as hexane. Vegetable oils are also
leached from other biological products, such as peanuts, rape seeds, and sunflower seeds. Soluble sucrose
is leached by water extraction from sugar cane and beets.

5. M emb r a ne p r ocessing

Separation of molecules by the use of membranes is a relatively new separation process and is becoming
more important. The relatively thin, solid membrane controls the rate of movement of molecules between
two phases. It is used to remove salt from water, to purify gases, in food processing, and so on.

6 . C r y st a lliza t ion

Solute components soluble in a solution can be removed from a solution by adjusting the conditions,
such as temperature or concentration, so that the solubility of one or more of the components is exceeded
and they crystallize out as a solid phase. Examples of this separation process are crystallization of sugar
from solution and crystallization of metal salts in the processing of metal ore solutions.

7. Ad sor p t ion

In an adsorption process, one or more components of a liquid or gas stream are adsorbed on the surface
or in the pores of a solid adsorbent and a separation is obtained. Examples include removal of organic
compounds from polluted water, separation of paraffins from aromatics, and removal of solvents from
air.

8. Ion excha ng e

In an ion-exchange process, certain ions are removed by an ion-exchange solid. This separation process
closely resembles adsorption.

10.1C . Pr oce ssing M e thod s

Several methods of processing are used in the separations discussed above. The two phases, such as gas
and liquid, or liquid and liquid, can be mixed together in a vessel and then separated. This is a single-
stage process. Often the phases are mixed in one stage, separated, and then brought into contact again
in a multiple-stage process. These two methods can be carried out batchwise or continuously. In still
another general method, the two phases can be contacted continuously in a packed tower.

In this chapter, humidification and absorption will be considered; in Chapter 11, distillation; in Chapter
12, adsorption, ion exchange, liquid–liquid extraction, leaching, and crystallization; in Chapter 13,
membrane processes; and in Chapter 14, mechanical–physical separations. In these processes the
equilibrium relations between the two phases being considered must be known. This is discussed for gas–
liquid systems in Section 10.2 and for the other systems in Chapters 11, 12, and 13.
                             
                                                 
                                             
                                               
     

10.2. EQUILIBRIUM RELATIONS BETWEEN PHASES

10.2A. Phase  R u le  and  Eq u ilib r iu m

In order to predict the concentration of a solute in each of two phases in equilibrium, experimental
equilibrium data must be available. If the two phases are not at equilibrium, the rate of mass transfer is
proportional to the driving force, which is the departure from equilibrium. In all cases involving
equilibria, two phases are involved, such as gas–liquid or liquid–liquid. The important variables
affecting the equilibrium of a solute are temperature, pressure, and concentration.

The equilibrium between two phases in a given situation is restricted by the phase rule:

Equation 10.2-1

where P is the number of phases at equilibrium, C the number of total components in the two phases
when no chemical reactions are occurring, and F the number of variants or degrees of freedom of the
system. For example, for the gas–liquid system of CO2–air–water, there are two phases and three
components (considering air as one inert component). Then, by Eq. (10.2-1),

This means that there are 3 degrees of freedom. If the total pressure and temperature are set, only one
variable is left that can be set arbitrarily. If the mole fraction composition xA of CO2 (A) in the liquid
phase is set, the mole fraction composition y A or pressure pA in the gas phase is automatically
determined.

The phase rule does not tell us the partial pressure pA in equilibrium with the selected xA. The value of pA
must be determined experimentally. The two phases can, of course, be gas–liquid, liquid–solid, and so
on. For example, the equilibrium distribution of acetic acid between a water phase and an isopropyl ether
phase has been determined experimentally for various conditions.

10.2B. G as–Liq u id  Eq u ilib r iu m

1. G a s–liq u id  eq u ilib r iu m d a t a

To illustrate the obtaining of experimental gas–liquid equilibrium data, the system SO2–air–water will
be considered. An amount of gaseous SO2, air, and water are put in a closed container and shaken
repeatedly at a given temperature until equilibrium is reached. Samples of the gas and liquid are
analyzed to determine the partial pressure pA in atm of SO2 (A) in the gas and mole fraction xA in the
liquid. Figure 10.2-1 shows a plot of data from Appendix A.3 of the partial pressure pA of SO2 in the vapor
in equilibrium with the mole fraction xA of SO2 in the liquid at 293 K (20°C).

Figure 10.2-1. Equilibrium plot for SO2 –water system at 293 K (20°C).

2. Henr y 's la w

Often the equilibrium relation between pA in the gas phase and xA can be expressed by a straight-line
Henry's law equation at low concentrations:

Equation 10.2-2

where H is the Henry's law constant in atm/mole fraction for the given system. If both sides of Eq. (10.2-
2) are divided by total pressure P in atm,

Equation 10.2-3

where H' is the Henry's law constant in mole frac gas/mole frac liquid and is equal to H/P. Note that H'
depends on total pressure, whereas H does not.

In Fig. 10.2-1 the data follow Henry's law up to a concentration xA of about 0.005, where H = 29.6

atm/mol frac. In general, up to a total pressure of about 5 × 105 Pa (5 atm) the value of H is independent
of P. Data for some common gases with water are given in Appendix A.3.

EXAMPLE 10.2­1. Dissolved Oxygen Concentration in
Water
What will be the concentration of oxygen dissolved in water at 298 K when the solution is in
equilibrium with air at 1 atm total pressure? The Henry's law constant is 4.38 × 104 atm/mol
fraction.

S olu t ion: The partial pressure pA of oxygen (A) in air is 0.21 atm. Using Eq. (10.2-2),

Solving, xA = 4.80 × 10−6 mol fraction. This means that 4.80 × 10−6 mol O2 is dissolved in 1.0
mol water plus oxygen, or 0.000853 part O2/100 parts water.
                             
                                                 
                                             
                                               
     

10.3. SINGLE AND MULTIPLE EQUILIBRIUM CONTACT STAGES

10.3A. S ingle -S tage  Eq u ilib r iu m  C ontact

In many operations of the chemical and other process industries, the transfer of mass from one phase to
another occurs, usually accompanied by a separation of the components of the mixture, since one
component will be transferred to a larger extent than will another component.

A single-stage process can be defined as one in which two different phases are brought into intimate
contact with each other and then are separated. During the time of contact, intimate mixing occurs and
the various components diffuse and redistribute themselves between the two phases. If mixing time is
long enough, the components are essentially at equilibrium in the two phases after separation and the
process is considered a single equilibrium stage.

A single equilibrium stage can be represented as in Fig. 10.3-1. The two entering phases, L0 and V2, of
known amounts and compositions, enter the stage; mixing and equilibration occur; and the two exit
streams, L1 and V1, leave in equilibrium with each other. Making a total mass balance,

Equation 10.3-1

Figure 10.3-1. Single-stage equilibrium process.

where L is kg (lbm), V is kg, and M is total kg.

Assuming that three components, A, B and C, are present in the streams and making a balance on A and
C,

Equation 10.3-2

Equation 10.3-3
An equation for B is not needed since xA + xB + xC = 1.0. The mass fraction of A in the L stream is xA and
is y A in the V stream. The mass fraction of A in the M stream is xAM.

To solve the three equations, the equilibrium relations between the components must be known. In
Section 10.3B, this will be done for a gas–liquid system and in Chapter 11 for a vapor–liquid system.
Note that Eqs. (10.3-1)–(10.3-3) can also be written using mole units, with L and V having units of moles
and xA and y A units of mole fraction.

10.3B. S ingle -S tage  Eq u ilib r iu m  C ontact for  G as–Liq u id  S yste m

In the usual gas–liquid system the solute A is in the gas phase V, along with inert air B, and in the liquid
phase L, along with inert water C. Assuming that air is essentially insoluble in the water phase and that
water does not vaporize to the gas phase, the gas phase is a binary A–B and the liquid phase is a binary
A–C. Using moles and mole fraction units, Eq. (10.3-1) holds for a single-stage process for the total
material balance. Since component A is the only component that redistributes between the two phases, a
balance on A can be written as follows:

Equation 10.3-4

where L' is moles inert water C and V' is moles inert air B. Both L' and V' are constant and usually
known.

To solve Eq. (10.3-4), the relation between y A1 and xA1 in equilibrium is given by Henry's law:

Equation 10.3-5

If the solution is not dilute, equilibrium data in the form of a plot of pA or y A versus xA must be available,
as in Fig. 10.2-1.

EXAMPLE 10.3­1. Equilibrium Stage Contact for CO2–Air–
Water
A gas mixture at 1.0 atm pressure abs containing air and CO2 is contacted in a single-stage
mixer continuously with pure water at 293 K. The two exit gas and liquid streams reach
equilibrium. The inlet gas flow rate is 100 kg mol/h, with a mole fraction of CO2 of y A2 = 0.20.
The liquid flow rate entering is 300 kg mol water/h. Calculate the amounts and compositions
of the two outlet phases. Assume that water does not vaporize to the gas phase.

S olu t ion: The flow diagram is the same as given in Fig. 10.3-1. The inert water flow is L' = L0
= 300 kg mol/h. The inert air flow V' is obtained from Eq. (10.3-6):

Equation 10.3-6

Hence, the inert air flow is V' = V2(1 − y A2) = 100(1 − 0.20) = 80 kg mol/h. Substituting into
Eq. (10.3-4) to make a balance on CO2 (A),

Equation 10.3-7

At 293 K, the Henry's law constant from Appendix A.3 is H = 0.142 × 104 atm/mol frac. Then
H' = H/P = 0.142 × 104/1.0 = 0.142 × 104 mol frac gas/mol frac liquid. Substituting into Eq.
(10.3-5),

Equation 10.3-8

Substituting Eq. (10.3-8) into (10.3-7) and solving, xA1 = 1.41 × 10−4 and y A1 = 0.20. To
calculate the total flow rates leaving,

In this case, since the liquid solution is so dilute, L0 ≅ L1.

10.3C . C ou nte r cu r r e nt M u ltip le -C ontact S tage s

1. Der iv a t ion of g ener a l eq u a t ion

In Section 10.3A we used single-stage contact to transfer the solute A between the V and L phases. In
order to transfer more solute from, say, the V1 stream, the single-stage contact can be repeated by again
contacting the V1 stream leaving the first stage with fresh L0. This can be repeated using multiple stages.
However, this is wasteful of the L0 stream and gives a dilute product in the outlet L1 streams. To
conserve use of the L0 stream and to get a more concentrated product, countercurrent multiple-stage
contacting is generally used. This is somewhat similar to countercurrent heat transfer in a heat
exchanger, where the outlet heated stream approaches more closely the temperature of the inlet hot
stream.

The process flow diagram for a countercurrent stage process is shown in Fig. 10.3-2. The inlet L stream is
L0 and the inlet V stream is VN+1 instead of V2 as for a single-stage in Fig. 10.3-1. The outlet product
streams are V1 and LN  and the total number of stages is N. The component A is being exchanged between
the V and L streams. The V stream is composed mainly of component B and the L stream of component
C. Components B and C may or may not be somewhat miscible in each other. The two-phase system can
be gas–liquid, vapor–liquid, liquid–liquid, or other.

Figure 10.3-2. Countercurrent multiple-stage process.

Making a total overall balance on all stages,

Equation 10.3-9

where VN+1 is mol/h entering LN  is mol/h leaving the process, and M is the total flow. Note in Fig. 10.3-2
that any two streams leaving a stage are in equilibrium with each other. For example, in stage n, Vn  and
Ln  are in equilibrium. For an overall component balance on A, B, or C,

Equation 10.3-10

where x and y are mole fractions. Flows in kg/h (lbm/h) and mass fraction can also be used in these
equations.

Making a total balance over the first n stages,

Equation 10.3-11

Making a component balance over the first n stages,

Equation 10.3-12
Solving for y n+1 in Eq. (10.3-12),

Equation 10.3-13

This is an important material-balance equation, often called an operating line. It relates the
concentration y n+1 in the V stream with xn  in the L stream passing it. The terms V1, y 1, L0, and x0 are
constant and are usually known or can be determined from Eqs. (10.3-9)–(10.3-12).

2. C ou nt er cu r r ent  cont a ct  w it h immiscib le st r ea ms

An important case in which the solute A is being transferred occurs when the solvent stream V contains
components A and B with no C and the solvent stream L contains A and C with no B. The two streams L
and V are immiscible in each other, with only A being transferred. When Eq. (10.3-13) is plotted on an x-y
plot (xA and y A of component A) such as Fig. 10.3-3, it is often curved, since the slope Ln /Vn+1 of the
operating line varies if the L and V streams vary from stage to stage.

Figure 10.3-3. Number of stages in a countercurrent multiple-stage contact process.

In Fig. 10.3-3 the equilibrium line that relates the compositions of two streams leaving a stage in
equilibrium with each other is plotted. To determine the number of ideal stages required to bring about a
given separation or reduction of the concentration of A from y N+1 to y 1, the calculation is often done
graphically. Starting at stage 1, y 1 and x0 are on the operating line, Eq. (10.3-13), plotted in the figure.
The vapor y 1 leaving is in equilibrium with the leaving x1 and both compositions are on the equilibrium
line. Then y 2 and x1 are on the operating line and y 2 is in equilibrium with x2, and so on. Each stage is
represented by a step drawn on Fig. 10.3-3. The steps are continued on the graph until y N+1 is reached.
Alternatively, we can start at y N+1 and draw the steps going to y 1.

If the streams L and V are dilute in component A, the streams are approximately constant and the slope
Ln /Vn+1 of Eq. (10.3-13) is nearly constant. Hence, the operating line is essentially a straight line on an
x-y plot. In distillation, where only components A and B are present, Eq. (10.3-13) also holds for the
operating line; this will be covered in Chapter 11. Cases where A, B, and C are appreciably soluble in each
other often occur in liquid–liquid extraction and will be discussed in Chapter 12.

Example 10.3­2. Absorption of Acetone in a
Countercurrent Stage Tower
It is desired to absorb 90% of the acetone in a gas containing 1.0 mol % acetone in air in a
countercurrent stage tower. The total inlet gas flow to the tower is 30.0 kg mol/h, and the total
inlet pure water flow to be used to absorb the acetone is 90 kg mol H2O/h. The process is to
operate isothermally at 300 K and a total pressure of 101.3 kPa. The equilibrium relation for
the acetone (A) in the gas–liquid is y A = 2.53xA. Determine the number of theoretical stages
required for this separation.

S olu t ion: The process flow diagram is similar to Fig. 10.3-3. Given values are y AN+1 = 0.01,


xA0 = 0, VN+1 = 30.0 kg mol/h, and L0 = 90.0 kg mol/h. Making an acetone material balance,

Since the flow of liquid varies only slightly from L0 = 90.0 at the inlet to LN  = 90.27 at the
outlet and V from 30.0 to 29.73, the slope Ln /Vn+1 of the operating line in Eq. (10.3-13) is
essentially constant. This line is plotted in Fig. 10.3-4 together with the equilibrium relation
y A = 2.53xA. Starting at point y A1, xA0, the stages are drawn as shown. About 5.2 theoretical
stages are required.

Figure 10.3-4. Theoretical stages for countercurrent absorption in Example 10.3-2.
10.3D. Analytical Eq u ations for  C ou nte r cu r r e nt S tage  C ontact

When the flow rates V and L in a countercurrent process are essentially constant, the operating-line
equation (10.3-13) becomes straight. If the equilibrium line is also a straight line over the concentration
range, simplified analytical expressions can be derived for the number of equilibrium stages in a
countercurrent stage process.

Referring again to Fig. 10.3-2, Eq. (10.3-14) is an overall component balance on component A:

Equation 10.3-14

Rearranging,

Equation 10.3-15

Making a component balance for A on the first n stages,

Equation 10.3-16

Rearranging,

Equation 10.3-17
Equating Eq. (10.3-15) to (10.3-17),

Equation 10.3-18

Since the molar flows are constant, Ln  = LN  = constant = L and Vn+1 = VN+1 = constant = V. Then Eq.


(10.3-18) becomes

Equation 10.3-19

Since y n+1 and xn+1 are in equilibrium and the equilibrium line is straight, y n+1 = mxn+1. Also, y N+1 =


mxN+1. Substituting mxn+1 for y n+1 and calling A = L/mV, Eq. (10.3-19) becomes

Equation 10.3-20

where A is an absorption factor and is constant.

All factors on the right-hand side of Eq. (10.3-20) are constant. This equation is a linear first-order
difference equation and can be solved by the calculus of finite-difference methods (G1, M1). The final
derived equations are as follows.

For transfer of solute A from phase L to V (stripping),

Equation 10.3-21

Equation 10.3-22

When A = 1,
Equation 10.3-23

For transfer of solute A from phase V to L (absorption),

Equation 10.3-24

Equation 10.3-25

When A = 1,

Equation 10.3-26

The term A is often called the absorption factor and S the stripping factor, where S = 1/A. These
equations can be used with any consistent set of units such as mass flow and mass fraction or molar flow
and mole fraction. Such series of equations are often called Kremser equations and are convenient to use.

If the equilibrium line is not straight but curved somewhat, the slope will vary and, hence, m and A =
L/mV will vary. For absorption (referring to Fig. 10.3-3) at the concentrated end, the slope mN  or tangent
of the equilibrium line at the concentrations y N , xN  leaving this bottom stage N is used. This mN  is at
point xN  on the equilibrium line. For the top or dilute end at stage 1 of the tower, the slope of the
equilibrium line m1 at the concentrations y 1, x1 leaving this stage is employed. This m1 is at point y 1 on
the equilibrium line. Then AN  = LN /mN VN+1 and A1 = L0/m1V1. The geometric average is used, where 

 (P1, T3). Also, the dilute m1 is used in Eqs. (10.3-24)–(10.3-26).

For stripping at the top or concentrated stage, the slope m1 or tangent to the equilibrium line at the
concentrations y 1, x1 leaving this stage is used. This m1 is at point y 1 on the equilibrium line. At the
bottom stage or dilute end of the tower, the slope mN  of the equilibrium line at the points y N , xN  is used.

This mN  is at xN  on the equilibrium line. Then, AN  = LN /mN VN+1, A1 = L0/m1V1, and  .


Again the dilute mN  is used in Eqs. (10.3-21)–(10.3-23). Sometimes only the values of A and m at the
dilute end are used since more of the stages are in this region.

Example 10.3­3. Number of Stages by Analytical Equation.
Repeat Example 10.3-2 but use the Kremser analytical equations for countercurrent stage
processes.

S olu t ion: At one end of the process at stage 1, V1 = 29.73 kg mol/h, y A1 = 0.00101, L0 = 90.0,


and xA0 = 0. Also, the equilibrium relation is y A = 2.53xA where m = 2.53. Then,

At stage N, VN+1 = 30.0, y AN+1 = 0.01, LN  = 90.27, and xAN  = 0.00300.

The geometric average 

The acetone solute is transferred from the V to the L phase (absorption). Substituting into Eq.
(10.3-25),

This compares closely with 5.2 stages obtained using the graphical method.
                             
                                                 
                                             
                                               
     

10.4. MASS TRANSFER BETWEEN PHASES

10.4 A. Intr od u ction and  Eq u ilib r iu m  R e lations

1. Int r od u ct ion t o int er p ha se ma ss t r a nsfer

In Chapter 7 we considered mass transfer from a fluid phase to another phase, which was most often a
solid phase. The solute A was usually transferred from the fluid phase by convective mass transfer and
through the solid by diffusion. In the present section we shall be concerned with the mass transfer of
solute A from one fluid phase by convection and then through a second fluid phase by convection. For
example, the solute may diffuse through a gas phase and then diffuse through and be absorbed in an
adjacent and immiscible liquid phase. This occurs in the case of absorption of ammonia from air by
water.

The two phases are in direct contact with each other, such as in a packed, tray, or spray-type tower, and
the interfacial area between the phases is usually not well defined. In two-phase mass transfer, a
concentration gradient will exist in each phase, causing mass transfer to occur. At the interface between
the two fluid phases, equilibrium exists in most cases.

2. Eq u ilib r iu m r ela t ions

Even when mass transfer is occurring, equilibrium relations are important to determine concentration
profiles for predicting rates of mass transfer. In Section 10.2 the equilibrium relation in a gas–liquid
system and Henry's law were discussed. In Section 7.1C a discussion covered equilibrium distribution
coefficients between two phases. These equilibrium relations will be used in discussion of mass transfer
between phases in this section.

10.4 B. C once ntr ation Pr ofile s in Inte r p hase  M ass Tr ansfe r

In the majority of mass-transfer systems, two phases, which are essentially immiscible in each other, are
present together with an interface between these two phases. Assuming solute A is diffusing from the
bulk gas phase G to the liquid phase L, it must pass through phase G, through the interface, and then
into phase L in series. A concentration gradient must exist to cause this mass transfer through the
resistances in each phase, as shown in Fig. 10.4-1. The average or bulk concentration of A in the gas
phase in mole fraction units is y AG, where y AG = pA/P, and in the bulk liquid phase in mole fraction units
it is xAL.

Figure 10.4-1. Concentr ation profile of solute A diffu sing through two phases.


The concentration in the bulk gas phase y AG decreases to y Ai at the interface. The liquid concentration
starts at xAi at the interface and falls to xAL. At the interface, since there would be no resistance to
transfer across this interface, y Ai and xAi are in equilibrium and are related by the equilibrium
distribution relation

Equation 10.4-1

where y Ai is a function of xAi. They are related by an equilibrium plot such as Fig. 10.1-1. If the system
follows Henry's law, y AP or pA and xA are related by Eq. (10.2-2) at the interface.

Experimentally, the resistance at the interface has been shown to be negligible for most cases of mass
transfer where chemical reactions do not occur, such as absorption of common gases from air to water
and extraction of organic solutes from one phase to another. However, there are some exceptions. Certain
surface-active compounds may concentrate at the interface and cause an “interfacial resistance” that
slows down the diffusion of solute molecules. Theories for predicting when interfacial resistance may
occur are often obscure and unreliable.

10.4 C . M ass Tr ansfe r  Using Film  M ass-Tr ansfe r  C oe fficie nts and  Inte r face  C once ntr ations

1. Eq u imola r  cou nt er d iffu sion

For equimolar counterdiffusion the concentrations of Fig. 10.4-1 can be plotted on an x-y diagram as in
Fig. 10.4-2. Point P represents the bulk phase compositions xAG and xAL of the two phases and point M
the interface concentrations y Ai and xAi. For A diffusing from the gas to liquid and B in equimolar
counterdiffusion from liquid to gas,

Equation 10.4-2

Figure 10.4-2. Concentration driving forces and interface concentrations in interphase mass transfer
(equimolar counterdiffusion).
where   is the gas-phase mass-transfer coefficient in kg mol/s · m2 · mol frac (g mol/s · cm2 · mol frac,

lb mol/h · ft 2 · mol frac) and   the liquid-phase mass-transfer coefficient in kg mol/s · m2 · mol frac (g


mol/s · cm2 · mol frac, lb mol/h · ft 2 · mol frac). Rearranging Eq. (10.4-2),

Equation 10.4-3

The driving force in the gas phase is (y AG − y Ai) and in the liquid phase it is (xAi − xAL). The slope of the

line PM is   This means that if the two film coefficients   and   are known, the interface

compositions can be determined by drawing line PM with a slope   intersecting the equilibrium
line.

The bulk-phase concentrations y AG and xAL can be determined by simply sampling the mixed bulk gas
phase and sampling the mixed bulk liquid phase. The interface concentrations are determined by Eq.
(10.4-3).

2. Diffu sion of A t hr ou g h st a g na nt  or  nond iffu sing  B

For the common case of A diffusing through a stagnant gas phase and then through a stagnant liquid
phase, the concentrations are shown in Fig. 10.4-3, where P again represents bulk-phase compositions
and M interface compositions. The equations for A diffusing through a stagnant gas and then through a
stagnant liquid are
Equation 10.4-4

Figure 10.4-3. Concentration driving forces and interface concentrations in interphase mass transfer (A
diffusing through stagnant B).

Now,

Equation 10.4-5

where

Equation 10.4-6

Equation 10.4-7
Then,

Equation 10.4-8

Note that (1 − y A)iM is the same as y BM of Eq. (7.2-11) but is written for the interface, and (1 − xA)iM is the


same as xBM of Eq. (7.2-11). Using Eq. (10.4-8) and rearranging,

Equation 10.4-9

The slope of the line PM in Fig. 10.4-3 to obtain the interface compositions is given by the left-hand side
of Eq. (10.4-9). This differs from the slope of Eq. (10.4-3) for equimolar counterdiffusion by the terms (1 −
y A)iM and (1 − xA)iM. When A is diffusing through stagnant B and the solutions are dilute, (1 − y A)iM and
(1 − xA)iM are close to 1.

A trial-and-error method is needed to use Eq. (10.4-9) to get the slope, since the left-hand side contains
the terms y Ai and xAi that are being sought. For the first trial (1 − y A)iM and (1 − xA)iM are assumed to be
1.0, and Eq. (10.4-9) is used to get the slope and y Ai and xAi values. Then for the second trial, these
values of y Ai and xAi are used to calculate a new slope to get new values of y Ai and xAi. This is repeated
until the interface compositions do not change. Three trials are usually sufficient.

EXAMPLE 10.4-1. Interface Compositions in Interphase
Mass Transfer
The solute A is being absorbed from a gas mixture of A and B in a wetted-wall tower with the
liquid flowing as a film downward along the wall. At a certain point in the tower the bulk gas
concentration y AG = 0.380 mol fraction and the bulk liquid concentration is xAL = 0.100. The

tower is operating at 298 K and 1.013 × 105 Pa and the equilibrium data are as follows:

xA yA xA yA

0 0 0.20 0.131
0.05 0.022 0.25 0.187

0.10 0.052 0.30 0.265


0.15 0.087 0.35 0.385

The solute A diffuses through stagnant B in the gas phase and then through a nondiffusing
liquid.

Using correlations for dilute solutions in wetted-wall towers, the film mass-transfer coefficient
for A in the gas phase is predicted as ky  = 1.465 × 10−3 kg mol A/s · m2 · mol frac (1.08 lb
mol/h · ft 2 · mol frac) and for the liquid phase as kx = 1.967 × 10−3 kg mol A/s · m2 · mol frac

(1.45 lb mol/h · ft 2 · mol frac). Calculate the interface concentrations y Ai and xAi and the flux


NA.

S olu t ion: Since the correlations are for dilute solutions, (1 − y A)iM and (1 − xA)iM are

approximately 1.0 and the coefficients are the same as   and  . The equilibrium data are


plotted in Fig. 10.4-4. Point P is plotted at y AG = 0.380 and xAL = 0.100. For the first trial, (1
− y A)iM and (1 − xA)iM are assumed as 1.0 and the slope of line PM is, from Eq. (10.4-9),

Figure 10.4-4. Location of interface concentrations for Example 10.4-1.

A line through point P with a slope of −1.342 is plotted in Fig. 10.4-4 intersecting the
equilibrium line at M1, where y Ai = 0.183 and xAi = 0.247.

For the second trial we use y Ai and xAi from the first trial to calculate the new slope.
Substituting into Eqs. (10.4-6) and (10.4-7),
Substituting into Eq. (10.4-9) to obtain the new slope,

A line through point P with a slope of −1.163 is plotted and intersects the equilibrium line at
M, where y Ai = 0.197 and xAi = 0.257.

Using these new values for the third trial, the following values are calculated:

This slope of −1.160 is essentially the same as the slope of −1.163 for the second trial. Hence,
the final values are y Ai = 0.197 and xAi = 0.257 and are shown as point M.

To calculate the flux, Eq. (10.4-8) is used:
Note that the flux NA through each phase is the same as in the other phase, which should be
the case at steady state.

10.4 D. Ov e r all M ass-Tr ansfe r  C oe fficie nts and  Dr iv ing For ce s

1. Int r od u ct ion

Film or single-phase mass-transfer coefficients   and   or ky  and kx are often difficult to measure


experimentally, except in certain experiments designed so that the concentration difference across one

phase is small and can be neglected. As a result, overall mass-transfer coefficients   and   are


measured based on the gas phase or liquid phase. This method is used in heat transfer, where overall
heat-transfer coefficients are measured based on inside or outside areas instead of film coefficients.

The overall mass transfer   is defined as

Equation 10.4-10

where   is based on the overall gas-phase driving force in kg mol/s · m2 · mol frac, and   is the value

that would be in equilibrium with xAL, as shown in Fig. 10.4-2. Also,   is defined as

Equation 10.4-11
where   is based on the overall liquid-phase driving force in kg mol/s · m2 · mol frac and   is the value
that would be in equilibrium with y AG.

2. Eq u imola r  cou nt er d iffu sion a nd /or  d iffu sion in d ilu t e solu t ions

Equation (10.4-2) holds for equimolar counterdiffusion, or, when the solutions are dilute, Eqs. (10.4-8)
and (10.4-2) are identical:

Equation 10.4-2

From Fig. 10.4-2,

Equation 10.4-12

Between the points E and M the slope m' can be given as

Equation 10.4-13

Solving Eq. (10.4-13) for (y Ai −  ) and substituting into Eq. (10.4-12),

Equation 10.4-14

Then, on substituting Eqs. (10.4-10) and (10.4-2) into (10.4-14) and canceling out NA,

Equation 10.4-15

The left-hand side of Eq. (10.4-15) is the total resistance based on the overall gas driving force and equals
the gas film resistance   plus the liquid film resistance  .

In a similar manner, from Fig. 10.4-2,

Equation 10.4-16

Equation 10.4-17

Proceeding as before,

Equation 10.4-18

Several special cases of Eqs. (10.4-15) and (10.4-18) will now be discussed. The numerical values of 

and   are very roughly similar. The values of the slopes m' and m'' are very important. If m' is quite
small, so that the equilibrium curve in Fig. 10.4-2 is almost horizontal, a small value of y A in the gas will
give a large value of xA in equilibrium in the liquid. The gas solute A is then very soluble in the liquid

phase, and hence the term   in Eq. (10.4-15) is very small. Then,

Equation 10.4-19

and the major resistance is in the gas phase, or the “gas phase is controlling.” The point M has moved
down very close to E, so that

Equation 10.4-20
Similarly, when m" is very large, the solute A is very insoluble in the liquid,   becomes small,
and

Equation 10.4-21

The “liquid phase is controlling” and xAi ≅  . Systems for absorption of oxygen or CO2 from air by water
are similar to Eq. (10.4-21).

3. Diffu sion of A t hr ou g h st a g na nt  or  nond iffu sing  B

For the case of A diffusing through nondiffusing B, Eqs. (10.4-8) and (10.4-14) hold and Fig. 10.4-3 is
used:

Equation 10.4-8

Equation 10.4-14

We must, however, define the equations for the flux using overall coefficients as follows:

Equation 10.4-22

The bracketed terms are often written as follows:

Equation 10.4-23

where Ky  is the overall gas mass-transfer coefficient for A diffusing through stagnant B and Kx the overall
liquid mass-transfer coefficient. These two coefficients are concentration-dependent. Substituting Eqs.
(10.4-8) and (10.4-22) into (10.4-14), we obtain

Equation 10.4-24

where

Equation 10.4-25

Similarly, for  ,

Equation 10.4-26

where

Equation 10.4-27

It should be noted that the relations derived here also hold for any two-phase system, where y stands for
one phase and x for the other phase. For example, for the extraction of the solute acetic acid (A) from
water (y phase) by isopropyl ether (x phase), the same relations will hold.

EXAMPLE 10.4-2. Overall Mass-Transfer Coefficients from
Film Coefficients

Using the same data as in Example 10.4-1, calculate the overall mass-transfer coefficient  ,
the flux, and the percent resistance in the gas and liquid films. Do this for the case of A
diffusing through stagnant B.
S olu t ion: From Fig. 10.4-4,   = 0.052, which is in equilibrium with the bulk liquid xAL =
0.10. Also, y AG = 0.380. The slope of chord m' between E and M from Eq. (10.4-13) is, for y Ai =
0.197 and xAi = 0.257,

From Example 10.4-1,

Using Eq. (10.4-25),

Then, using Eq. (10.4-24),

Solving,   = 8.90 × 10−4. The percent resistance in the gas film is (484.0/868.8)100 =
55.7% and in the liquid film 44.3%. The flux is as follows, using Eq. (10.4-22):

This, of course, is the same flux value as was calculated in Example 10.4-1 using the film
equations.
4 . Discu ssion of ov er a ll coefficient s

If the two-phase system is such that the major resistance is in the gas phase, as in Eq. (10.4-19), then to
increase the overall rate of mass transfer, efforts should be centered on increasing the gas-phase
turbulence, not the liquid-phase turbulence. For a two-phase system where the liquid film resistance is
controlling, turbulence should be increased in this phase to increase rates of mass transfer.

To design mass-transfer equipment, the overall mass-transfer coefficient is synthesized from the
individual film coefficients, as discussed in this section.

Generally, when the major resistance to mass transfer is in the gas phase, the overall mass transfer

coefficient   or the film coefficient   is used. An example would be absorption of ammonia from air to

water. When the major resistance is in the liquid phase, as in absorption of oxygen from air by water, 

or   is used.
                             
                                                 
                                             
                                               
     

10.5. CONTINUOUS HUMIDIFICATION PROCESSES

10.5A. Intr od u ction and  Typ e s of Eq u ip m e nt for  Hu m id ification

1. Int r od u ct ion t o g a s–liq u id  cont a ct or s

When a relatively warm liquid is brought into direct contact with gas that is unsaturated, some of the
liquid is vaporized. The liquid temperature will drop mainly because of the latent heat of evaporation.
This direct contact of a gas with a pure liquid occurs most often in contacting air with water. This is done
for the following purposes: humidifying air for control of the moisture content of air in drying or air
conditioning; dehumidifying air, where cold water condenses some water vapor from warm air; and
water cooling, where evaporation of water to the air cools warm water.

In Chapter 9 the fundamentals of humidity and adiabatic humidification were discussed. In this section
the performance and design of continuous air–water contactors is considered. The emphasis is on
cooling of water, since this is the most important type of process in the process industries. There are
many cases in industry in which warm water is discharged from heat exchangers and condensers when it
would be more economical to cool and reuse it than to discard it.

2. Tow er s for  w a t er  cooling

In a typical water-cooling tower, warm water flows countercurrent to an air stream. Typically, the warm
water enters the top of a packed tower and cascades down through the packing, leaving at the bottom.
Air enters at the bottom of the tower and flows upward through the descending water. The tower packing
often consists of slats of plastic or of a packed bed. The water is distributed by troughs and overflows to
cascade over slat gratings or packing that provides large interfacial areas of contact between the water
and air in the form of droplets and films of water. The flow of air upward through the tower can be
induced by the buoyancy of the warm air in the tower (natural draft) or by the action of a fan. Detailed
descriptions of towers are given in other texts (B1, T1).

The water cannot be cooled below the wet bulb temperature. The driving force for the evaporation of the
water is approximately the vapor pressure of the water less the vapor pressure it would have at the wet
bulb temperature. The water can be cooled only to the wet bulb temperature, and in practice it is cooled to
about 3 K or more above this. Only a small amount of water is lost by evaporation in cooling water. Since
the latent heat of vaporization of water is about 2300 kJ/kg, a typical change of about 8 K in water
temperature corresponds to an evaporation loss of about 1.5%. Hence, the total flow of water is usually
assumed to be constant in calculations of tower size.

In humidification and dehumidification, intimate contact between the gas phase and liquid phase is
needed for large rates of mass transfer and heat transfer. The gas-phase resistance controls the rate of
transfer. Spray or packed towers are used to give large interfacial areas and to promote turbulence in the
gas phase.

10.5B. The or y and  C alcu lations for  W ate r -C ooling Tow e r s


1. Temp er a t u r e a nd  concent r a t ion p r ofiles a t  int er fa ce

In Fig. 10.5-1 the temperature profile and concentration profile in terms of humidity are shown at the
water–gas interface. Water vapor diffuses from the interface to the bulk gas phase with a driving force in
the gas phase of (Hi − HG) kg H2O/kg dry air. There is no driving force for mass transfer in the liquid
phase, since water is a pure liquid. The temperature driving force is TL − Ti in the liquid phase and Ti −
TG K or °C in the gas phase. Sensible heat flows from the bulk liquid to the interface in the liquid. Sensible
heat also flows from the interface to the gas phase. Latent heat also leaves the interface in the water
vapor, diffusing to the gas phase. The sensible heat flow from the liquid to the interface equals the
sensible heat flow in the gas plus the latent heat flow in the gas.

Figure 10.5-1. Temperature and concentration profiles in upper part of cooling tower.

The conditions in Fig. 10.5-1 occur at the upper part of the cooling tower. In the lower part of the cooling
tower, the temperature of the bulk water is higher than the wet bulb temperature of the air but may be
below the dry bulb temperature. Then the direction of the sensible heat flow in Fig. 10.5-1 is reversed.

2. R a t e eq u a t ions for  hea t  a nd  ma ss t r a nsfer

We shall consider a packed water-cooling tower with air flowing upward and water countercurrently
downward in the tower. The total interfacial area between the air and water phases is unknown, since the
surface area of the packing is not equal to the interfacial area between the water droplets and the air.
Hence, we define a quantity a, defined as m2 of interfacial area per m3 volume of packed section, or
m2/m3. This is combined with the gas-phase mass-transfer coefficient kG in kg mol/s · m2 Pa or kg mol/s

· m2 · atm to give a volumetric coefficient kGa in kg mol/s · m3 volumePa or kg mol/s · m3 · atm (lb mol/h

· ft 3 · atm).

The process is carried out adiabatically; the various streams and conditions are shown in Fig. 10.5-2,
where

Figure 10.5-2. Continuous countercurrent adiabatic water cooling.
The enthalpy Hy  as given in Eq. (9.3-8) is

Equation 9.3-8

The base temperature selected is 0°C or 273 K (32°F). Note that (T − T0)°C = (T − T0) K.

Making a total heat balance for the dashed-line box shown in Fig. 10.5-2, an operating line is obtained:

Equation 10.5-1

This assumes that L is essentially constant, since only a small amount is evaporated. The heat capacity
cL of the liquid is assumed constant at 4.187 × 103 J/kg · K (1.00 btu/lbm · °F). When plotted on a chart
of Hy  versus TL, Eq. (10.5-1) is a straight line with a slope of LcL/G. Making an overall heat balance over
both ends of the tower,

Equation 10.5-2

Again, making a heat balance for the dz column height and neglecting sensible-heat terms compared to
the latent heat,

Equation 10.5-3

The total sensible heat transfer from the bulk liquid to the interface is (refer to Fig. 10.5-1)

Equation 10.5-4

where hLa is the liquid-phase volumetric heat-transfer coefficient in W/m3 · K (btu/h · ft 3 · °F) and Ti is
the interface temperature.

For adiabatic mass transfer the rate of heat transfer due to the latent heat in the water vapor being
transferred can be obtained from Eq. (9.3-16) by rearranging and using a volumetric basis:

Equation 10.5-5

where qλ/A is in W/m2 (btu/h · ft 2), MB = molecular weight of air, kGa is a volumetric mass-transfer

coefficient in the gas in kg mol/s · m3 · Pa, P = atm pressure in Pa, λ 0 is the latent heat of water in J/kg
water, Hi is the humidity of the gas at the interface in kg water/kg dry air, and HG is the humidity of the
gas in the bulk gas phase in kg water/kg dry air. The rate of sensible heat transfer in the gas is

Equation 10.5-6

where qS/A is in W/m2 and hG a is a volumetric heat-transfer coefficient in the gas in W/m3 · K.
Now from Fig. 10.5-1, Eq. (10.5-4) must equal the sum of Eqs. (10.5-5) and (10.5-6):

Equation 10.5-7

Equation (9.3-18) states that

Equation 10.5-8

Substituting PkGa for ky a,

Equation 10.5-9

Substituting Eq. (10.5-9) into Eq. (10.5-7) and rearranging,

Equation 10.5-10

Adding and subtracting cST0 inside the brackets,

Equation 10.5-11

The terms inside the braces are (Hyi − Hy ), and Eq. (10.5-11) becomes

Equation 10.5-12

Integrating, the final equation to use for calculating the tower height is

Equation 10.5-13
If Eq. (10.5-4) is equated to Eq. (10.5-12) and the result rearranged,

Equation 10.5-14

10.5C . De sign of W ate r -C ooling Tow e r  Using Film  M ass-Tr ansfe r  C oe fficie nts

The tower design is done using the following steps:

1. The enthalpy of saturated air Hyi is plotted versus Ti on an H-versus-T plot as shown in Fig. 10.5-3.
This enthalpy is calculated by means of Eq. (9.3-8) using the saturation humidity from the humidity
chart for a given temperature, with 0°C (273 K) as a base temperature. Calculated values are
tabulated in Table 10.5-1.

Table 10.5-1. Enthalpies of Saturated Air–Water Vapor Mixtures (0°C Base Temperature)

Hy Hy

TL btu J TL btu J

°F °C lbm  dry air kg dry air °F °C lbm  dry air kg dry air

60 15.6 18.78 43.68 × 103 100 37.8 63.7 148.2 × 103

80 26.7 36.1 84.0 × 103 105 40.6 74.0 172.1 × 103

85 29.4 41.8 97.2 × 103 110 43.3 84.8 197.2 × 103

90 32.2 48.2 112.1 × 103 115 46.1 96.5 224.5 × 103

95 35.0 55.4 128.9 × 103 140 60.0 198.4 461.5 × 103

Figure 10.5-3. Temperature enthalpy diagram and operating line for water-cooling tower.
2. Knowing the entering air conditions TG1 and H1, the enthalpy of this air Hy1 is calculated from Eq.
(9.3-8). The point Hy1 and TL1 (desired leaving water temperature) is plotted in Fig. 10.5-3 as one
point on the operating line. The operating line is plotted with a slope LcL/G and ends at point TL2,
which is the entering water temperature. This gives Hy2. Alternatively, Hy2 can be calculated from
Eq. (10.5-2).

3. Knowing hLa and kGa, lines with a slope of −hLa/kGaMBP are plotted as shown in Fig. 10.5-3. From
Eq. (10.5-14), point P represents Hy  and TL on the operating line, and point M represents Hyi and Ti,
the interface conditions. Hence, line MS or Hyi − Hy  represents the driving force in Eq. (10.5-13).

4 . The driving force Hyi − Hy  is computed for various values of TL between TL1 and TL2. Then the
function 1/(Hyi − Hy ) is integrated from Hy1 to Hy2 by numerical or graphical integration to obtain
the value of the integral in Eq. (10.5-13). Finally, the height z is calculated from Eq. (10.5-13).

10.5D. De sign of W ate r -C ooling Tow e r  Using Ov e r all M ass-Tr ansfe r  C oe fficie nts

Often, only an overall mass-transfer coefficient KGa in kg mol/s · m3 · Pa or kg mol/s · m3 · atm is
available, and Eq. (10.5-13) becomes

Equation 10.5-15
The value of   is determined by going vertically from the value of Hy  at point P up to the equilibrium

line to give   at point R, as shown in Fig. 10.5-3. In many cases the experimental film coefficients kGa
and hLa are not available. The few experimental data available indicate that hLa is quite large; the slope
of the lines −hLa/(kGaMBP) in Eq. (10.5-14) would be very large and the value of Hyi would approach

that of   in Fig. 10.5-3.

The tower design using the overall mass-transfer coefficient is done using the following steps:

1. The enthalpy–temperature data from Table 10.5-1 are plotted as shown in Fig. 10.5-3.

2. The operating line is calculated as in steps 1 and 2 for the film coefficients and plotted in Fig. 10.5-3.

3.

In Fig. 10.5-3 point P represents Hy  and TL on the operating line and point R represents   on the

equilibrium line. Hence, the vertical line RP or   − Hy  represents the driving force in Eq. (10.5-15).

4.

The driving force   − Hy  is computed for various values of TL between TL1 and TL2. Then the

function 1/(   − Hy ) is integrated from Hy1 to Hy2 by numerical or graphical methods to obtain


the value of the integral in Eq. (10.5-15). Finally, the height z is obtained from Eq. (10.5-15).

If experimental cooling data from an actual run in a cooling tower with known height z are available,
then, using Eq. (10.5-15), the experimental value of KGa can be obtained.

EXAMPLE 10.5-1. Design of Water-Cooling Tower Using
Film Coefficients
A packed countercurrent water-cooling tower using a gas flow rate of G = 1.356 kg dry air/s ·
m2 and a water flow rate of L = 1.356 kg water/s · m2 is to cool the water from TL2 = 43.3°C
(110°F) to TL1 = 29.4°C (85°F). The entering air at 29.4°C has a wet bulb temperature of

23.9°C. The mass-transfer coefficient kGa is estimated as 1.207 × 10−7  kg mol/s · m3 · Pa and

hLa/kGaMBP as 4.187 × 104 J/kg · K (10.0 btu/lbm · °F). Calculate the height of packed tower
z. The tower operates at a pressure of 1.013 × 105 Pa.

S olu t ion: Following the steps outlined, the enthalpies from the saturated air–water vapor
mixtures from Table 10.5-1 are plotted in Fig. 10.5-4. The inlet air at TG1 = 29.4°C has a wet
bulb temperature of 23.9°C. The humidity from the humidity chart is H1 = 0.0165 kg H2O/kg
dry air. Substituting into Eq. (9.3-8), noting that (29.4 − 0)°C = (29.4 − 0) K,

Figure 10.5-4. Graphical solution of Example 10.5-1.

The point Hy1 = 71.7 × 103 and TL1 = 29.4°C is plotted. Then substituting into Eq. (10.5-2)
and solving,

Hy2 = 129.9 × 103 J/kg dry air (55.8 btu/lbm). The point Hy2 = 129.9 × 103 and TL2 = 43.3°C

is also plotted, giving the operating line. Lines with slope −hLa/kGaMBP = −41.87 × 103 J/kg ·
K are plotted, giving Hyi and Hy  values, which are tabulated in Table 10.5-2 along with derived
values as shown. Values of the function 1/(Hyi − Hy ) are used with numerical integration

between the values Hy1 = 71.7 × 103 to Hy2 = 129.9 × 103 to obtain the integral

Table 10.5-2. Enthalpy Values for Solution to Example 10.5-1 (enthalpy in J/kg dry air)
Hyi Hy Hyi  − Hy 1/(Hyi  − Hy )

94.4 × 103 71.7 × 103 22.7 × 103 4.41 × 10−5

108.4 × 103 83.5 × 103 24.9 × 103 4.02 × 10−5

124.4 × 103 94.9 × 103 29.5 × 103 3.39 × 10−5

141.8 × 103 106.5 × 103 35.3 × 103 2.83 × 10−5

162.1 × 103 118.4 × 103 43.7 × 103 2.29 × 10−5

184.7 × 103 129.9 × 103 54.8 × 103 1.82 × 10−5

Substituting into Eq. (10.5-13),

10.5E. M inim u m  Valu e  of Air  Flow

Often the air flow G is not fixed but must be set for the design of the cooling tower. As shown in Fig. 10.5-
5, for a minimum value of G, the operating line MN is drawn through the point Hy1 and TL1 with a slope
that touches the equilibrium line at TL2, point N. If the equilibrium line is quite curved, line MN could
become tangent to the equilibrium line at a point farther down the equilibrium line than point N. For the
actual tower, a value of G greater than Gmin  must be used. Often, a value of G equal to 1.3 to 1.5 times
Gmin  is used.

Figure 10.5-5. Operating-line construction for minimum gas flow.
10.5F. De sign of W ate r -C ooling Tow e r  Using He ight of a Tr ansfe r  Unit

Often another form of the film mass-transfer coefficient is used in Eq. (10.5-13):

Equation 10.5-16

Equation 10.5-17

where HG is the height of a gas enthalpy transfer unit in m, and the integral term is called the number of
transfer units. The term HG is often used since it is less dependent upon flow rates than kGa.

In many cases another form of the overall mass-transfer coefficient KGa in kg mol/s · m3· Pa or kg mol/s ·

m3 · atm is used, and Eq. (10.5-15) becomes

Equation 10.5-18
where HOG is the height of an overall gas enthalpy transfer unit in m. The value of   is determined by
going vertically from the value of Hy  up to the equilibrium line, as shown in Fig. 10.5-3. This method
should be used only when the equilibrium line is almost straight over the range used. However, the HOG
is often used even if the equilibrium line is somewhat curved because of the lack of film mass-transfer-
coefficient data.

10.5G . Te m p e r atu r e  and  Hu m id ity of Air  S tr e am  in Tow e r

The procedures outlined above do not yield any information on the changes in temperature and humidity
of the air–water vapor stream through the tower. If this information is of interest, a graphical method by
Mickley (M2) is available. The equation used for the graphical method is derived by first setting Eq.
(10.5-6) equal to GcSdTG and then combining it with Eqs. (10.5-12) and (10.5-9) to yield Eq. (10.5-19):

Equation 10.5-19

10.5H. De hu m id ification Tow e r

For the cooling or humidification tower discussed above, the operating line lies below the equilibrium
line, and water is cooled and air humidified. In a dehumidification tower, cool water is used to reduce the
humidity and temperature of the air that enters. In this case the operating line is above the equilibrium
line. Similar calculation methods are used (T1).
                             
                                                 
                                             
                                               
     

10.6. ABSORPTION IN PLATE AND PACKED TOWERS

10.6 A. Intr od u ction to Ab sor p tion

As discussed briefly in Section 10.1B, absorption is a mass-transfer process in which a vapor solute A in a
gas mixture is absorbed by means of a liquid in which the solute is more or less soluble. The gas mixture
consists mainly of an inert gas and the solute. The liquid also is primarily immiscible in the gas phase;
that is, its vaporization into the gas phase is relatively slight. A typical example is absorption of the
solute ammonia from an air–ammonia mixture by water. Subsequently, the solute is recovered from the
solution by distillation. In the reverse process of desorption or stripping, the same principles and
equations hold.

Equilibrium relations for gas–liquid systems in absorption were discussed in Section 10.2, and such data
are needed for design of absorption towers. Some data are tabulated in Appendix A.3. Other, more
extensive data are available in Perry and Green (P1, P2).

10.6 B. Eq u ip m e nt for  Ab sor p tion and  Distillation

1. Va r iou s t y p es of t r a y  (p la t e) t ow er s for  a b sor p t ion a nd  d ist illa t ion

In order to efficiently bring the vapor and liquid into contact in absorption and distillation, tray towers of
the following types are often used.

1.  Sieve tray. The sieve tray shown in Fig. 10.6-1a is very common. Essentially the same tray is used
in distillation and gas absorption. In the sieve tray, vapor bubbles up through simple holes in the
tray through the flowing liquid. Hole sizes range from 3 to 12 mm in diameter, with 5 mm a
common size. The vapor area of the holes varies between 5 to 15% of the tray area. The liquid is
held on the tray surface and prevented from flowing down through the holes by the kinetic energy
of the gas or vapor. The depth of liquid on the tray is maintained by an overflow, outlet weir. The
overflow liquid flows into the downspout to the next tray below.

Figure 10.6-1. Tray contacting devices: (a) detail of sieve-tr ay tower, (b) detail of valve-tr ay tower.


2.  Valve tray. A modification of the sieve tray is the valve tray shown in Fig. 10.6-1b. This consists of
an opening in the tray and a lift-valve cover with guides to keep the cover properly positioned over
the opening. This provides a variable open area which is varied by the vapor flow inhibiting
leakage of liquid down the opening at low vapor rates. Hence, this type of tray can operate over a
greater range of flow rates than the sieve tray, with a cost of only about 20% more than a sieve
tray. The valve tray is being increasingly used today (S5).

3.  Bubble-cap tray. Bubble-cap trays have been used for over 100 years, but since 1950 they have
been generally superseded by sieve-type or valve trays because of their cost, which is almost
double that of sieve-type trays. In the bubble tray, the vapor or gas rises through the opening in
the tray into the bubble caps. Then the gas flows through slots in the periphery of each cap and
bubbles upward through the flowing liquid. Details and design procedures for many of these and
other types of trays are given elsewhere (B2, P2, T1). Efficiencies for the different types of trays are
discussed in Section 11.5.

2. S t r u ct u r ed  p a ck ing  for  a b sor p t ion a nd  d ist illa t ion

Structured packing has become competitive with conventional tray towers, especially in tower revamps
where increased capacity and/or efficiency is desired (K1, L2). A typical corrugated-sheet packing is
shown in Fig. 10.6-2 (F1). The thin corrugated-metal sheets are formed in a triangular cross-section, as
shown in Fig. 10.6-2a. The vapor flow goes upward through the triangular channels, which are set at a
45° angle with the vertical. The sheets are arranged so the liquid flows downward in the opposite
direction and spreads over the surfaces, as in a wetted-wall tower.

Figure 10.6-2. Typical corrugated structured packing: (a) triangular cross section of flow channel; (b) flow-
channel arrangement, with vapor flowing upward, indicated by arrows, and liquid downward. [From J. R. Fair
and J. L. Bravo, Chem. Eng. Progr., 86, (Jan.), 19 (1990). With permission.]
The corrugated sheets are assembled into an element whose height E, as shown in Fig. 10.6-2b, is about
20 to 30 cm tall (8–12 in.). A shorter height tends to increase the liquid and vapor spread in the
horizontal plane. Each adjacent element is rotated 90° in the horizontal plane with respect to the layer
below in order to spread the liquid and vapor uniformly in all radial planes. The ratios of B/h in Fig. 10.6-
2a are in the range of 2/1 to 4/1. The size ranges of the triangle are typically: for B, 2.4–4.0 cm, for S, 1.7–
2.6 cm, and for h, 1.2–1.8 cm (K1). Smaller sizes of the triangle mean that more sheets are present, giving
a greater surface area. This results in a higher efficiency but smaller openings. However, the increased
resistance to gas flow gives a lower capacity and a greater sensitivity to plugging (K1).

The open void fraction typically varies from 0.91 to 0.96 and the specific surface area from 165 to 330
m2/m3 volume (50 to 100 ft 2/ft 3). In many cases the packing sheet contains perforations or holes about
2–4 mm ID spaced 0.5–1.5 cm apart to help wet both the upper and lower sides of the sheet.

3. Pa ck ed  t ow er s for  a b sor p t ion a nd  d ist illa t ion

Packed towers are used for continuous countercurrent contacting of gas and liquid in absorption as well
as for vapor–liquid contacting in distillation. The tower in Fig. 10.6-3 consists of a cylindrical column
containing a gas inlet and distributing space at the bottom, a liquid inlet and distributing device at the
top, a gas outlet at the top, a liquid outlet at the bottom, and a packing or filling in the tower. The gas
enters the distributing space below the packed section and rises upward through the openings or
interstices in the packing and contacts the descending liquid flowing through the same openings. A large
area of intimate contact between the liquid and gas is provided by the packing.

Figure 10.6-3. Packed tower flows and characteristics for absorption.
4 . Ty p es of r a nd om p a ck ing  for  a b sor p t ion a nd  d ist illa t ion

Many different types of tower packings have been developed and a number are used quite often. Common
types of packing which are dumped at random in the tower are shown in Fig. 10.6-4. Such packings and
other commercial packings are available in sizes of 3 mm to about 75 mm. Most of the tower packings are
made of materials such as clay, porcelain, metal, or plastic. High void spaces of 65–95% are
characteristic of good packings. The packings permit relatively large volumes of liquid to pass
countercurrent to the gas flow through the openings with relatively low pressure drops for the gas. These
same types of packings are also used in vapor–liquid separation processes of distillation.

Figure 10.6-4. Typical random or dumped tower packings: (a) Raschig ring; (b) Berl saddle; (c) Pall ring; (d)
Intalox metal, IMTP; (e) Jaeger Metal Tri-Pack.

Ceramic Raschig rings and Berl saddles shown in Figs. 10.6-4a and b are older types of random packing
and are seldom used now (K1). Pall rings (second-generation packing) shown in Fig. 10.6-4c, are made of
plastic or metal; they are much more efficient and are still used now. They have porosities or void spaces
of 0.90–0.96 and areas of 100–200 m2/m3 (30–60 ft 2/ft 3). The latest or third-generation packings are
the Intalox metal type, shown in Fig. 10.6-4d, which is a combination of the Berl saddle and the Pall
ring, and the Metal Tri-Pack, shown in Fig. 10.6-4e, which is a Pall ring in spherical shape. Porosities
range from 0.95 to 0.98. Many other types of new packings are available. These third-generation
packings are only slightly more efficient than the Pall rings.

Stacked packings having sizes of 75 mm or so and larger are also used. The packing is stacked vertically,
with open channels running uninterruptedly through the bed. The advantage of the lower pressure drop
of the gas is offset in part by the poorer gas–liquid contact in stacked packings. Typical stacked packings
are wood grids, drip-point grids, spiral partition rings, and others.

10.6 .C . Pr e ssu r e  Dr op  and  Flood ing in Packe d  Tow e r s

In a given packed tower with a given type and size of packing and with a definite flow of liquid, there is
an upper limit to the rate of gas flow, called the flooding velocity. Above this gas velocity the tower
cannot operate. At low gas velocities the liquid flows downward through the packing, essentially
uninfluenced by the upward gas flow. As the gas flow rate is increased at low gas velocities, the pressure
drop is proportional to the flow rate to the 1.8 power. At a gas flow rate called the loading point, the gas
starts to hinder the liquid downflow, and local accumulations or pools of liquid start to appear in the
packing. The pressure drop of the gas starts to rise at a faster rate. As the gas flow rate is increased, the
liquid holdup or accumulation increases. At the flooding point, the liquid can no longer flow down
through the packing and is blown out with the gas.

In an actual, operating tower, the gas velocity is well below flooding. The optimum economic gas velocity
is about one-half or more of the flooding velocity. It depends upon a balance of economic factors
including equipment cost, pressure drop, and processing variables. Pressure drop in the packing is an
important consideration in design of a tower and is covered in detail below.

1. Pr essu r e d r op  in r a nd om p a ck ing s

Empirical correlations for various random packings based on experimental data are used to predict the
pressure drop in the gas flow. The original correlation by Eckert (K1) correlated the gas and liquid flow
rates and properties with pressure drop. The latest version has been replotted by Strigle (K1, S4) and is
shown in Fig. 10.6-5. The line for ΔP = 2.0 in. H2O/ft has been extrapolated. The ordinate (capacity

parameter) is vG[ρG/(ρL − ρG)]0.5  ν0.05 and the abscissa (flow parameter) is (GL/GG)(ρG/ρL)0.5,

where vG is superficial gas velocity in ft/s, ρG is gas density in lbm/ft 3, vG = GG/ρG, ρL is liquid density in

lbm/ft 3, Fp is a packing factor in ft −1, v is kinematic viscosity μL/(ρL/62.4) in centstokes, μL is liquid

viscosity in cp, GL is liquid mass velocity in lbm/(s · ft 2), and GG is gas mass velocity in lbm/(s · ft 2).Note


that this capacity parameter is not dimensionless and that only these units should be used. This
correlation predicts pressure drops to an accuracy of ±11% (L2).

Figure 10.6-5. Pressure-drop correlation for random packings by Strigle. (From R. F. Strigle, Jr., Random
Packings and Packed Towers, Houston: Gulf Publishing Company, 1987. With permission from Elsevier
Science.)
The packing factor Fp is almost inversely proportional to packing size. This packing factor Fp is
determined empirically for each size and type of packing, and some data are given in Table 10.6-1. A very
extensive list of values of Fp is given by Kister (K1).

Table 10.6-1. Packing Factors for Random and Structured Packing

Relative
Surface mass-
area, a, Packing transfer
Void factor, Fp , ft
Nominal fraction, ft 2 /ft 3 coefficient,
Type Material size, in. ε (m 2 /m 3 ) −1  (m −1 ) fp

Random Packing
Raschig Rings Ceramic 1/2 0.64 111 (364) 580 (1900) 1.52

      1 0.74 58 (190) 179 (587) 1.20

      1 1/2 0.73 37 (121) 95 (312) 1.00


      2 0.74 28 (92) 65 (213) 0.85

Berl Saddles Ceramic 1/2 0.62 142 (466) 240 (787) 1.58

      1 0.68 76 (249) 110 (361) 1.36


      2   32 (105) 45 (148)  

Pall Rings Metal 1 0.94 63 (207) 56 (184) 1.61


      1 1/2 0.95 39 (128) 40 (131) 1.34

      2 0.96 31 (102) 27 (89) 1.14


Metal Intalox (IMTP) Metal 1 0.97 70 (230) 41 (134) 1.78
      2 0.98 30 (98) 18 (59) 1.27

Nor-Pac Plastic 1 0.92 55 (180) 25 (82)  

      2 0.94 31 (102) 12 (39)  


Hy-Pak Metal 1 0.96 54 (177) 45 (148) 1.51

      2 0.97 29 (95) 26 (85) 1.07


    Plastic 1 0.92 55 (180) 25 (82)  
      2 0.94 31 (102) 12 (39)  
Structured Packing
Mellapak 250Y Metal   0.95 76 (249) 20 (66)  

  500Y       152 (499) 34 (112)  

Flexipac 2     0.93 68 (223) 22 (72)  


  4     0.98     6 (20)  
Gempak 2A     0.93 67 (220) 16 (52)  

  4A     0.91 138 (452) 32 (105)  

Norton Intalox 2T     0.97 65 (213) 17 (56) 1.98


  3T     0.97 54 (177) 13 (43) 1.94
Montz B300       91 (299) 33 (108)  

Sulzer CY Wire   0.85 213 (700) 70 (230)  


    Mesh              

  BX     0.90 150 (492) 21 (69)  


Data from Ref. (K1, L2, P2, S4). The relative mass-transfer coefficient, fp , is discussed in Section
10.8B.

2. Pr essu r e d r op  in st r u ct u r ed  p a ck ing s

An empirical correlation for structured packings is given in Fig. 10.6-6 by Kister and Gill (K1). They
modified the Eckert correlation for random packings to better fit only the structured-packing data. An
extrapolated line for ΔP = 0.05 in. H2O/ft and for ΔP = 2.0 has been added. The packing factors Fp to be
used for structured packing are those given in Table 10.6-1 and references (K1, L2, P2). The units on the
ordinate and abscissa of Fig. 10.6-6 are the same as those for Fig. 10.6-5.

Figure 10.6-6. Pressure-drop correlation for structured packings by Kister and Gill (K2). (From H. Z. Kister,
Distillation Design, New York: McGraw-Hill Book Company, 1992. With permission.)
3. Flood ing  p r essu r e d r op  in p a ck ed  a nd  st r u ct u r ed  p a ck ing s

It is important for proper design to be able to predict the flooding pressure drop in towers and, hence, the
limiting flow rates at flooding. Figures 10.6-5 and 10.6-6 do not predict flooding conditions. Kister and
Gill (K2) have developed an empirical equation to predict the limiting pressure drop at flooding. This
equation is

Equation 10.6-1

where ΔPflood is in in. H2O/ft height of packing and Fp is the packing factor in ft −1 given in Table 10.6-1
for random or structured packing. To convert from English to SI units, 1.00 in. H2O/ft height = 83.33
mm H2O/m height of packing. This can be used for packing factors from 9 up to 60. It predicts all of the
data for flooding within ±15% and most for ±10%. At a packing factor of 60 or higher, Eq. (10.6-1) should
not be used; instead, the pressure drop at flooding can be taken as 2.00 in. H2O/ft (166.7 mm H2O/m).

The following procedure can be used to determine the limiting flow rates and the tower diameter.

1. First, a suitable random packing or structured packing is selected, giving an Fp value.

2. A suitable liquid-to-gas ratio GL/GG is selected along with the total gas flow rate.

3. The pressure drop at flooding is calculated using Eq. (10.6-1), or if Fp is 60 or over, the ΔPflooding is
taken as 2.0 in./ft packing height.

4 . Then the flow parameter is calculated, and using the pressure drop at flooding and either Fig. 10.6-5
or 10.6-6, the capacity parameter is read off the plot.

5. Using the capacity parameter, the value of GG is obtained, which is the maximum value at flooding.

6 . Using a suitable % of the flooding value of GG for design, a new GG and GL are obtained. The pressure
drop can also be obtained from Figure 10.6-5 or 10.6-6.

7. Knowing the total gas flow rate and GG, the tower cross-sectional area and ID can be calculated.

4 . Ap p r oxima t e d esig n fa ct or s t o u se

In using random packing, the radio of tower diameter to packing size should be 10/1 or greater. This is to
ensure good liquid and gas distribution. For every 3 m (10 ft) height of packing, a liquid redistribution
should be used to prevent channeling of liquid to the sides. Random-packed towers are generally used
only for diameters of 1.0 m (3.3 ft) or less. Tray towers less than 0.6 m (2 ft) in diameter are usually not
used because of cleaning and access problems.
The start of loading in packed towers is usually at about 65–70% of the flooding velocity (L2). For
absorption, the tower should be designed using about 50–70% of the gas flooding velocity, with the high
value used at high flow parameters. For atmospheric-pressure distillation, values of 70–80% can be used
(S5). For distillation and structured packing, 80% of flooding is often used in design (L3). For tray
towers, see Section 11.5.

EXAMPLE 10.6-1. Pressure Drop and Tower Diameter for
Ammonia Absorption
Ammonia is being absorbed in a tower using pure water at 25°C and 1.0 atm abs pressure. The
feed rate is 1440 lbm/h (653.2 kg/h) and contains 3.0 mol % ammonia in air. The process
design specifies a liquid-to-gas mass flow rate ratio GL/GG of 2/1 and the use of 1-in. metal
Pall rings.

a.  Calculate the pressure drop in the packing and gas mass velocity at flooding. Using
50% of the flooding velocity, calculate the pressure drop, gas and liquid flows, and
tower diameter.

b.  Repeat (a) above but use Mellapak 250Y structured packing.

S olu t ion: The gas and liquid flows in the bottom of the tower are the largest, so the tower will
be sized for these flows. Assume that approximately all of the ammonia is absorbed. The gas
average mol wt is 28.97(0.97) + 17.0(0.03) = 28.61. The weight fraction of ammonia is
0.03(17)/(28.61) = 0.01783.

Assuming the water is dilute, from Appendix A.2-4, the water viscosity μ = 0.8937 cp. From
A.2-3, the water density is 0.99708 gm/cm3. Then, ρL = 0.99708(62.43) = 62.25 lbm/ft 3.
Also, v = μ/ρ = 0.8937/0.99708 = 0.8963 centistokes.

From Table 10.6-1, for 1-in. Pall rings, Fp = 56 ft −1. Using Eq. 10.6-1, ΔPflood = 0.115  =

0.115(56)0.7  = 1.925 in. H2O/ft packing height. The flow parameter for Fig. 10.6-5 is

Using Fig. 10.6-5, for a flow parameter of 0.06853 (abscissa) and a pressure drop of 1.925
in./ft at flooding, a capacity parameter (ordinate) of 1.7 is read off the plot. Then, substituting
into the capacity parameter equation and solving for vG,
vG = 6.663 ft/s. Then GG = vGρG = 6.663(0.07309) = 0.4870 lbm/(s · ft 2) at flooding. Using

50% of the flooding velocity for design, GG = 0.5(0.4870) = 0.2435 lbm/(s · ft 2) [1.189 kg/(s ·

m2)]. Also, the liquid flow rate GL = 2.0(0.2435) = 0.4870 lbm/(s · ft 2) [2.378 kg/(s · m2)].

To calculate the tower pressure drop at 50% of flooding, GG = 0.2435 and GL = 0.4870, the
new capacity parameter is 0.5(1.7) = 0.85. Using this value of 0.85 and the same flow
parameter, 0.06853, a value of 0.18 in. water/ft is obtained from Fig. 10.6-5.

The tower cross-sectional area = (1440/3600 lbm/s)(1/0.2435 lbm/(s · ft 2)) = 1.6427 ft 2 =

(π/4)D2. Solving, D = 1.446 ft (0.441 m). The amount of ammonia in the outlet water
assuming all of the ammonia is absorbed is 0.01783(1440) = 25.68 lb. Since the liquid flow
rate is 2 times the gas flow rate, the total liquid flow rate is 2.0(1440) = 2880 lbm/hr. Hence,
the flow rate of the pure inlet water is 2880 − 25.68 = 2858.3 lbm/s.

For part (b), using Mellapak 250Y, Fp = 20 from Table 10.6-1. The Δpflood = 0.115  =

0.115(20)0.7  = 0.936 in. water/ft. The flow parameter of 0.06853 is the same. Using Fig. 10.6-
6, a capacity parameter = 1.38 at flooding is obtained. Then,

Solving, GG = 0.6615 lbm/(h · ft 2). For 50% flood, GG = 0.5(0.6615) = 0.3308 lbm/(s · ft 2)

[1.615 kg/(s · m2)]. Also, the liquid flow rate is GL = 2(0.3308) = 0.6616 lbm/(s · ft 2) [3.230

kg/(s · m2)]. The new capacity parameter is 0.5(1.38) = 0.69. Using this and Fig. 10.6-6, a
pressure drop of 0.11 in. water/ft is obtained.

The tower cross-sectional area = (1440/3600)(1/0.3308) = 1.209 ft 2 = (π/4)D2. Solving, D =
1.241 ft (0.3784 m). Note that the tower with structured packing uses about 25% less cross-
sectional area.

10.6 D. De sign of Plate  Ab sor p tion Tow e r s

1. Op er a t ing -line d er iv a t ion


A plate (tray) absorption tower has the same process flow diagram as the countercurrent multiple-stage
process in Fig. 10.3-2 and is shown as a vertical tray tower in Fig. 10.6-7. In the case of solute A diffusing
through a stagnant gas (B) and then into a stagnant fluid, as in the absorption of acetone (A) from air (B)
by water, the moles of inert or stagnant air and inert water remain constant throughout the entire tower.
If the rates are V' kg mol inert air/s and L' kg mol inert solvent water/s or in kg mol inert/s · m2 units (lb
mol inert/h · ft 2), an overall material balance on component A in Fig. 10.6-7 is

Equation 10.6-2

Figure 10.6-7. Material balance in an absorption tray tower.

A balance around the dashed-line box gives

Equation 10.6-3

where x is the mole fraction A in the liquid, y the mole fraction of A in the gas, Ln  the total moles liquid/s,
and Vn+1 the total moles gas/s. The total flows/s of liquid and gas vary throughout the tower.

Equation (10.6-3) is the material balance or operating line for the absorption tower and is similar to Eq.
(10.3-13) for a countercurrent-stage process, except that the inert streams L' and V' are used instead of
the total flow rates L and V. Equation (10.6-3) relates the concentration y n+1 in the gas stream with xn  in
the liquid stream passing it. The terms V', L', x0, and y 1 are constant and are usually known or can be
determined.
2. G r a p hica l d et er mina t ion of t he nu mb er  of t r a y s

A plot of the operating-line equation (10.6-3) as y versus x will give a curved line. If x and y are very
dilute, the denominators 1 − x and 1 − y will be close to 1.0, and the line will be approximately straight,
with a slope ≅ L'/V'. The number of theoretical trays is determined by simply stepping off the number of
trays, as done in Fig. 10.3-3 for a countercurrent multiple-stage process.

EXAMPLE 10.6-2. Absorption of SO2 in a Tray Tower
A tray tower is to be designed to absorb SO2 from an air stream by using pure water at 293 K
(68°F). The entering gas contains 20 mol % SO2 and that leaving 2 mol % at a total pressure of

101.3 kPa. The inert air flow rate is 150 kg air/h · m2, and the entering water flow rate is 6000
kg water/h · m2. Assuming an overall tray efficiency of 25%, how many theoretical trays and
actual trays are needed? Assume that the tower operates at 293 K (20°C).

S olu t ion: First calculating the molar flow rates,

Referring to Fig. 10.6-7, y N+1 = 0.20, y 1 = 0.02, and x0 = 0. Substituting into Eq. (10.6-2) and


solving for xN ,

Substituting into Eq. (10.6-3), using V' and L' as kg mol/h · m2 instead of kg mol/s · m2,

In order to plot the operating line, several intermediate points will be calculated. Setting y n+1
= 0.07 and substituting into the operating equation,

Hence, xn  = 0.000855. To calculate another intermediate point, we set y n+1 = 0.13, and xn  is


calculated as 0.00201. The two end points and the two intermediate points on the operating
line are plotted in Fig. 10.6-8, as are the equilibrium data from Appendix A.3. The operating
line is somewhat curved.

Figure 10.6-8. Theoretical number of trays for absorption of SO2  in Example 10.6-2.

The number of theoretical trays is determined by stepping off the steps to give 2.4 theoretical
trays. The actual number of trays is 2.4/0.25 = 9.6 trays.

10.6 E. De sign of Packe d  Tow e r s for  Ab sor p tion

1. Op er a t ing -line d er iv a t ion

For the case of solute A diffusing through a stagnant gas and then into a stagnant fluid, an overall
material balance on component A in Fig. 10.6-9 for a packed tower is (note the notation change in Fig.
10.6-9 with inlets y 1 and x2)

Equation 10.6-4

Figure 10.6-9. Material balance for a countercurrent packed absorption tower.
where L' is kg mol inert liquid/s or kg mol inert liquid/s · m2, V' is kg mol inert gas/s or kg mol inert gas/s
· m2, and y 1 and x1 are mole fractions A in gas and liquid, respectively. The flows L' and V' are constant
throughout the tower, but the total flows L and V are not constant.

A balance around the dashed-line box in Fig. 10.6-9 gives the operating-line equation:

Equation 10.6-5

This equation, when plotted on yx coordinates, will give a curved line, as shown in Fig. 10.6-10a.
Equation (10.6-5) can also be written in terms of partial pressure p1 of A, where y 1/(1 − y 1) = p1/(P − p1),
and so on. If x and y are very dilute, (1 − x) and (1 − y) can be taken as 1.0 and Eq. (10.6-5) becomes

Equation 10.6-6

Figure 10.6-10. Location of operating lines: (a) for absorption of A from V to L stream, (b) for stripping of A
from L to V stream.
This has a slope L'/V' and the operating line is essentially straight.

When the solute is being transferred from the L to the V stream, the process is called stripping. The
operating line is below the equilibrium line, as shown in Fig. 10.6-10b.

2. Limit ing  a nd  op t imu m L'/V' r a t ios.

In the absorption process, the inlet gas flow V1 (Fig. 10.6-9) and its composition y 1 are generally set. The
exit concentration y 2 is also usually set by the designer, and the concentration x2 of the entering liquid is
often fixed by process requirements. Hence, the amount of the entering liquid flow L2 or L' is open to
choice.

In Fig. 10.6-11a the flow V1 and the concentrations y 2, x2, and y 1 are set. When the operating line has a

minimum slope and touches the equilibrium line at point P, the liquid flow L' is a minimum at  .
The value of x1 is a maximum at x1max when L' is a minimum. At point P the driving forces y − y*, y − y i,

x* − x, and xi − x are all zero. To solve for  , the values y 1 and x1max are substituted into the


operating-line equation. In some cases, if the equilibrium line is curved concavely downward, the
minimum value of L is reached by the operating line becoming tangent to the equilibrium line instead of
intersecting it.

Figure 10.6-11. Operating line for limiting conditions: (a) absorption, (b) stripping.
The choice of the optimum L'/V' ratio to use in the design depends on an economic balance. In
absorption, too high a value requires a large liquid flow and hence a large-diameter tower. The cost of
recovering the solute from the liquid by distillation will be high. A small liquid flow results in a high
tower, which is also costly. As an approximation, for absorption the optimum liquid flow rate can be

taken as 1.2–1.5 times the limiting rate  , with 1.5 usually used (S6).

For stripping or transfer of solute from L to V, where the operating line has a maximum slope and

touches the equilibrium line at point P in Fig. 10.6-11b, then the gas flow is at the minimum   The
value of y 2 is at a maximum at y 2max. As in absorption, the optimum gas flow rate is taken at about 1.5

times  . In liquid extraction, covered later in Section 12.7, the same conditions for stripping hold for
extracting solute from feed liquid L to solvent V.

3. Ana ly t ica l eq u a t ions for  t heor et ica l nu mb er  of st ep s or  t r a y s

Analytical equations to calculate the number of theoretical trays N in an absorption tower are the same as
Eqs. (10.3-22) and (10.3-25) for calculating the number of stages in countercurrent stage processes. These
are as follows. (Note that the notation refers to Fig. 10.6-9 and not Fig. 10.3-3.)

For transfer of the solute from phase V to phase L (absorption),

Equation 10.6-7

For transfer of the solute from phase L to phase V (stripping),

Equation 10.6-8
where A = L/mV.

If the equilibrium line and/or operating line is slightly curved, m and A = L/mV will vary. For absorption
(referring to Fig. 10.6-9), at the bottom concentrated end tray, the slope m1 or tangent at the point x1 on
the equilibrium line is used. At the dilute top tray, the slope m2 of the equilibrium line at point y 2 is used.

Then A1 = L1/m1V1, A2 = L2/m2V2, and  . Also, the dilute m2 is used in Eq. (10.6-7). For
stripping, at the top or concentrated stage, the slope m2 or tangent at point y 2 on the equilibrium line is
used. At the bottom or dilute end, the slope m1 at point x1 on the equilibrium line is used. Then, A1 =

L1/m1V1, A2 = L2/m2V2, and  . Again, the dilute m1 is used in Eq. (10.6-8).

EXAMPLE 10 6­3. Minimum Liquid Flow Rate and
Analytical Determination of Number of Trays
A tray tower is absorbing ethyl alcohol from an inert gas stream using pure water at 303 K and
101.3 kPa. The inlet gas stream flow rate is 100.0 kg mol/h and it contains 2.2 mol % alcohol.
It is desired to recover 90% of the alcohol. The equilibrium relationship is y = mx = 0.68x for
this dilute stream. Using 1.5 times the minimum liquid flow rate, determine the number of
trays needed. Do this graphically and also using the analytical equations.

S olu t ion: The given data are y 1 = 0.022, x2 = 0, V1 = 100.0 kg mol/h, m = 0.68. Then V' =


V1(1 − y 1) = 100.0(1 − 0.022) = 97.8 kg mol inert/h. Moles alcohol/h in V1 are 100 − 97.8 =
2.20. Removing 90%, moles/h in outlet gas V2 = 0.10(2.20) = 0.220. V2 = V' + 0.220 = 97.8 +
0.22 = 98.02. y 2 = 0.22/98.02 = 0.002244. The equilibrium line is plotted in Fig. 10.6-12
along with y 2, x2, and y 1. The operating line for minimum liquid flow Lmin is drawn from y 2, x2
to point P, touching the equilibrium line where x1max = y 1/m = 0.022/0.68 = 0.03235.
Substituting into the operating-line equation (10.6-4) and solving for Lmin ,

Figure 10.6-12. Operating line for minimum and actual liquid flow in Example 10.6-3.
 = 59.24 kg mol/h. Using 1.5 , L' = 1.5(59.24) = 88.86. Using L' = 88.86 in Eq.
(10.6-4) and solving for the outlet concentration, x1 = 0.02180. The operating line is plotted as
a straight line through the points y 2, x2 and y 1, x1 in Fig. 10.6-12. An intermediate point is
calculated by setting y = 0.012 in Eq. (10.6-5) and solving for x = 0.01078. Plotting this point
shows that the operating line is very linear. This occurs because the solutions are dilute.

The number of theoretical trays obtained by stepping them off is 4.0 trays. The total flow rates
are V1 = 100.0, V2 = V'/(1 − y 2) = 97.8/(1 − 0.002244) = 98.02, L2 = L' = 88.86, and L1 = L'/(1
− x1) = 88.86/(1 − 0.02180) = 90.84. To calculate the number of trays analytically, A1 =
L1/mV1 = 90.84/(0.68)(100) = 1.336, A2 = L2/mV2 = 88.86/(0.68)(98.02) = 1.333. Using the
geometric average, A = 1.335. Using Eq. (10.6-7),

N = 4.04 theoretical steps, which agrees closely with the 4.0 steps obtained graphically.

4 . Film a nd  ov er a ll ma ss-t r a nsfer  coefficient s in p a ck ed  t ow er s

As discussed in Section 10.5, it is very difficult to measure experimentally the interfacial area A m2
between phases L and V. Also, it is difficult to measure the film coefficients   and   and the overall

coefficients   and  . Usually, experimental measurements in a packed tower yield a volumetric mass-


transfer coefficient that combines the interfacial area and mass-transfer coefficient.

Defining a as interfacial area in m2 per m3 volume of packed section, the volume of packing in a height dz
m (Fig. 10.6-9) is S dz, and

Equation 10.6-9

where S is m2 cross-sectional area of tower. The volumetric film and overall mass-transfer coefficients are
then defined as

5. Desig n met hod  for  p a ck ed  t ow er s u sing  ma ss-t r a nsfer  coefficient s

For absorption of A from stagnant B, the operating-line equation (10.6-5) holds. For the differential
height of tower dz in Fig. 10.6-9, the moles of A leaving V equal the moles entering L:

Equation 10.6-10

where V = kg mol total gas/s, L = kg mol total liquid/s, and d(Vy) = d(Lx) = kg mol A transferred/s in
height dz m. The kg mol A transferred/s from Eq. (10.6-10) must equal the kg mol A transferred/s from
the mass-transfer equation for NA. Equation (10.4-8) gives the flux NA using the gas-film and liquid-film
coefficients:

Equation 10.4-8

where (1 − y A)iM and (1 − xA)iM are defined by Eqs. (10.4-6) and (10.4-7). Multiplying the left-hand side
of Eq. (10.4-8) by dA and the two right-side terms by aS dz from Eq. (10.6-9),

Equation 10.6-11

where NA dA = kg mol A transferred/s in height dz m (lb mol/h).

Equating Eq. (10.6-10) to (10.6-11) and using y AG for the bulk gas phase and xAL for the bulk liquid
phase,

Equation 10.6-12

Equation 10.6-13

Since V' = V(1 − y AG) or V = V'/(1 − y AG),

Equation 10.6-14

Substituting V for V'/(1 − y AG) in Eq. (10.6-14) and then equating Eq. (10.6-14) to (10.6-12),

Equation 10.6-15

Repeating for Eq. (10.6-13), since L = L'/(1 − xAL),

Equation 10.6-16
Dropping the subscripts A, G, and L and integrating, the final equations are as follows using film
coefficients:

Equation 10.6-17

Equation 10.6-18

In a similar manner, the final equations can be derived using overall coefficients:

Equation 10.6-19

Equation 10.6-20

In the general case, the equilibrium and the operating lines are usually curved, and  ,  ,   and 

 vary somewhat with total gas and liquid flows. Then Eqs. (10.6-17)–(10.6-20) must be integrated
numerically or graphically. The methods for doing this for concentrated mixtures will be discussed in
Section 10.7. Methods for dilute gases will be considered below.

10.6 F. S im p lifie d  De sign M e thod s for  Ab sor p tion of Dilu te  G as M ixtu r e s in Packe d  Tow e r s

Since a considerable percentage of the absorption processes include absorption of a dilute gas A, these
cases will be considered using a simplified design procedure.

The concentrations can be considered dilute for engineering design purposes when the mole fractions y
and x in the gas and liquid streams are less than about 0.10, that is, 10%. The flows will vary by less than
10% and the mass-transfer coefficients by considerably less than this. As a result, the average values of
the flows V and L and the mass-transfer coefficients at the top and bottom of the tower can be taken
outside the integral. Likewise, the terms (1 − y)iM/(1 − y), (1 − y)*M/(1 − y), (1 − x)iM/(1 − x), and (1 −
x)*M/(1 − x) can be taken outside and average values at the top and bottom of the tower used. (Often
these terms are close to 1.0 and can be dropped out entirely.) Then Eqs. (10.6-17)–(10.6-20) become

Equation 10.6-21

Equation 10.6-22

Equation 10.6-23

Equation 10.6-24

Since the solutions are dilute, the operating line will be essentially straight. Assuming the equilibrium
line is approximately straight over the range of concentrations used, (y − y i) varies linearly with y and
also with x:

Equation 10.6-25

where k and b are constants. Therefore, the integral of Eq. (10.6-21) can be integrated to give the
following:

Equation 10.6-26
where (y − y i)M is the log mean driving force:

Equation 10.6-27

Similarly, Eq. (10.6-23) gives

Equation 10.6-28

If the term (1 − y)iM/(1 − y) is considered 1.0, then by substituting Eq. (10.6-26) into (10.6-21) and doing
the same for Eqs. (10.6-22)–(10.6-24), the final results are as follows:

Equation 10.6-29

Equation 10.6-30

Equation 10.6-31

Equation 10.6-32
where the left side is the kg mol absorbed/s · m2 (lb mol/h · ft 2) by material balance and the right-hand
side is the rate equation for mass transfer. The value of V is the average (V1 + V2)/2 and of L is (L1 +
L2)/2.

Equations (10.6-29)–(10.6-32) can be used in slightly different ways. The general steps to follow are
discussed below and shown in Fig. 10.6-13.

1. The operating-line equation (10.6-5) is plotted as in Fig. 10.6-13 as a straight line. Calculate V1, V2,
and Vav  = (V1 + V2)/2; also calculate L1, L2, and Lav  = (L1 + L2)/2.

2.

Average experimental values of the film coefficients   and   are available or may be obtained


from empirical correlations. The interface compositions y i1 and xi1 at point y 1, x1 in the tower are
determined by plotting line P1M1, whose slope is calculated by Eq. (10.6-33):

Equation 10.6-33

Equation 10.6-34

If terms (1 − x)iM and (1 − y)iM are used, the procedure is trial and error, as in Example 10.4-1.
However, since the solutions are dilute, the terms (1 − x1) and (1 − y 1) can be used in Eq. (10.6-34)
without trial and error and with only a small error in slope. If the coefficients ky a and kxa are
available for the approximate concentration range, they can be used, since they include the terms (1
− x)iM and (1 − y)iM. For line P2M2 at the other end of the tower, values of y i2 and xi2 are determined
using Eq. (10.6-33) or (10.6-34) and y 2 and x2.

3.

If the overall coefficient   is being used,   and   are determined as shown in Fig. 10.6-13. If 

 is used,   and   are obtained.

4.
Calculate the log mean driving force (y − y i)M by Eq. (10.6-27) if   is used. For  , (y − y*)M is
calculated by Eq. (10.6-28). Using the liquid coefficients, the appropriate driving forces are
calculated.

5. Calculate the column height z m by substituting into the appropriate form of Eqs. (10.6-29)–(10.6-
32).

Figure 10.6-13. Operating-line and interface compositions in a packed tower for absorption of dilute gases.

EXAMPLE 10.6-4. Absorption of Acetone in a Packed
Tower
Acetone is being absorbed by water in a packed tower having a cross-sectional area of 0.186 m2
at 293 K and 101.32 kPa (1 atm). The inlet air contains 2.6 mol % acetone and outlet 0.5%. The
gas flow is 13.65 kg mol inert air/h (30.1 lb mol/h). The pure water inlet flow is 45.36 kg mol

water/h (100 lb mol/h). Film coefficients for the given flows in the tower are   = 3.78 × 10−2

kg mol/s · m3 · mol frac (8.50 lb mol/h · ft 3 · mol frac) and   = 6.16 × 10−2 kg mol/s · m3 ·


mol frac (13.85 lb mol/h · ft 3 · mol frac). Equilibrium data are given in Appendix A.3.

a.  Calculate the tower height using. .

b.  Repeat, using. .

c.  Calculate   and the tower height.


S olu t ion: From Appendix A.3 for acetone–water and xA = 0.0333 mol frac, pA = 30/760 =
0.0395 atm or y A = 0.0395 mol frac. Hence, the equilibrium line is y A = mxA or 0.0395 = m
(0.0333). Then, y = 1.186x. This equilibrium line is plotted in Fig. 10.6-14. The given data are
L' = 45.36 kg mol/h, V' = 13.65 kg mol/h, y 1 = 0.026, y 2 = 0.005, and x2 = 0.

Figure 10.6-14. Location of interface compositions for Example 10.6-4.

Substituting into Eq. (10.6-4) for an overall material balance using flow rates as kg mol/h
instead of kg mol/s,

The points y 1, x1 and y 2, x2 are plotted in Fig. 10.6-14 and a straight line is drawn for the


operating line.

Using Eq. (10.6-34) the approximate slope at y 1, x1 is

Plotting this line through y 1, x1, the line intersects the equilibrium line at y i1 = 0.0154 and xi1

= 0.0130. Also,   = 0.0077. Using Eq. (10.6-33) to calculate a more accurate slope, the
preliminary values of y i1 and xi1 will be used in the trial-and-error solution. Substituting into
Eq. (10.4-6),
Using Eq. (10.4-7),

Substituting into Eq. (10.6-33),

Hence, the approximate slope and interface values are accurate enough.

For the slope at point y 2, x2,

The slope changes little in the tower. Plotting this line, y i2 = 0.0020, xi2 = 0.0018, and   =
0.

Substituting into Eq. (10.6-27),

To calculate the total molar flow rates in kg mol/s,
For part (a), substituting into Eq. (10.6-29) and solving,

For part (b), using an equation similar to Eq. (10.6-27),

Substituting into Eq. (10.6-30) and solving,

This agrees with part (a) quite closely.

For part (c), substituting into Eq. (10.4-25) for point y 1, x1,
The overall mass-transfer coefficient   at point y 1, x1 is calculated by substituting into Eq.
(10.4-24):

Substituting into Eq. (10.6-28),

Finally, substituting into Eq. (10.6-31),

This is in agreement with parts (a) and (b).

10.6 G . De sign of Packe d  Tow e r s Using Tr ansfe r  Units

1. Desig n for  concent r a t ed  solu t ions

Another and in some ways more useful design method for packed towers is the use of the transfer-unit
concept. For the most common case of A diffusing through stagnant and nondiffusing B, Eqs. (10.6-17)–
(10.6-20) can be rewritten as

Equation 10.6-35

Equation 10.6-36
Equation 10.6-37

Equation 10.6-38

where

Equation 10.6-39

Equation 10.6-40

Equation 10.6-41

Equation 10.6-42

where (1 − y)iM is defined by Eq. (10.4-6), (1 − x)iM by Eq. (10.4-7), (1 − y)*M by Eq. (10.4-25), and (1 −
x)*M by Eq. (10.4-27). The units of H are in m (ft). HG is the height of a transfer unit based on the gas
film. The values of the heights of transfer units are more constant than the mass-transfer coefficients. For
example,   is often proportional to V0.7 , so then  . The average values of the
mass-transfer coefficients, (1 − y)iM, (1 − y)*M, (1 − x)iM, and (1 − x)*M, must be used in Eqs. (10.6-39)–
(10.6-42).

The integrals on the right side of Eqs. (10.6-35)–(10.6-38) are the number of transfer units NG, NL, NOG,
and NOL, respectively. The height of the packed tower is then

Equation 10.6-43

These equations are basically no different from those using mass-transfer coefficients. One still needs 

 and   to determine interface concentrations. Disregarding (1 − y)iM/(1 − y), which is near 1.0 in
Eq. (10.6-35), the greater the amount of absorption (y 1 − y 2) or the smaller the driving force (y − y i), the
larger the number of transfer units NG and the taller the tower.

2. Desig n for  d ilu t e solu t ions

When the solutions are dilute, with concentrations below 10%, the terms (1 − y)iM/(1 − y), (1 − x)iM/(1 −
x), (1 − y)*M/(1 − y), and (1 − x)*M/(1 − x) in Eqs. (10.6-35)–(10.6-38) can be taken outside the integral
and average values used. Since these are quite close to 1.0, they can be dropped out. The equations then
become

Equation 10.6-44

Equation 10.6-45

Equation 10.6-46

Equation 10.6-47
If both the operating and equilibrium lines are straight and dilute, the integrals in Eqs. (10.6-44)–(10.6-
47) can be integrated, giving the number of transfer units:

Equation 10.6-48

Equation 10.6-49

Equation 10.6-50

Equation 10.6-51

where (y − y i)M is defined in Eq. (10.6-27) and (y − y*)M in (10.6-28).

When the major resistance to mass transfer is in the gas phase, as in absorption of acetone from air by
water, the overall number of transfer units based on the gas phase NOG or the film NG should be used.
When the major resistance is in the liquid phase, as in absorption of O2 by water or stripping of a slightly
soluble solute from water, NOL or NL should be employed. This was also discussed in detail in Section
10.4D. Often the film coefficients are not available, and then it is more convenient to use NOG or NOL.

By combining the operating line with the integrals in Eqs. (10.6-46) and (10.6-47), using the
equilibrium-line equation y = mx, and letting A = L/mV, different forms of the equations for absorption
with NOG and for stripping with NOL are obtained:

Equation 10.6-52
Equation 10.6-53

The values of m and A to use in the above equations when operating and/or equilibrium lines are slightly
curved are discussed in detail in Section 10.6E for use with Eqs. (10.6-7) and (10.6-8).

When the operating and equilibrium lines are straight and not parallel, the number of overall gas-
transfer units NOG for absorption in Eq. (10.6-52) is related to the number of theoretical trays or stages N
in Eq. (10.6-7) by

Equation 10.6-54

The height of a theoretical tray or stage, HETP, in m is related to HOG by

Equation 10.6-55

A detailed discussion of HETP is given in Section 11.5D. Note that if the operating and equilibrium lines
are parallel (A = 1.0), then HOG = HETP and NOG = N. Equations (10.6-7) and (10.6-8) can be used to
analytically calculate N, the number of theoretical steps.

EXAMPLE 10 6­5. Use of Transfer Units and Analytical
Equations for Packed Tower
Repeat Example 10.6-4 using transfer units and height of a transfer unit as follows:

a.  Use HG and NG to calculate tower height.

b.  Use HOG and NOG to calculate tower height.

c.  Use Eq. (10.6-52) to calculate NOG and tower height.

d.  Using the analytical equations, calculate HETP from Eq. (10.6-55), number of
theoretical steps N from Eq. (10.6-7), and tower height.

S olu t ion: From Example 10.6-4,   = 3.78 × 10−2 kg mol/s · m2 · mol frac,   = 2.183 ×


10−2 kg mol/s · m2 · mol frac, average V = 3.852 × 10−3 kg mol/s, and S = 0.186 m2.

For part (a), from Eq. (10.6-39),
Note that often in the literature, the terms Hy , Hx, HOy , and HOx are used instead of HG, HL, HOG, and
HOL; they are identical to each other.
                                   
                                                       
                                                     
                                   

10.7. ABSORPTION OF CONCENTRATED MIXTURES IN PACKED TOWERS
In Section 10.6F simplified design methods were given for absorption of dilute gases in packed towers when the mole
fractions in the gas and liquid streams were less than about 10%. Straight operating lines and approximately straight
equilibrium lines are obtained. In concentrated gas mixtures the operating line and usually the equilibrium line will be

substantially curved and   and   may vary with total flows. Then the design equations (10.6-17)–(10.6-20) must


be integrated graphically or numerically:

Equation 10.6-17

Equation 10.6-18

Equation 10.6-19

Equation 10.6-20

The detailed general steps to follow are as follows:

1. The operating-line equation (10.6-5) and the equilibrium line are plotted.

2.

The values of the film coefficients   and   are obtained from empirical equations. These two film coefficients


are functions of  , kg total gas/s · m2, and  , kg total liquid/s · m2, where n and m are in the range 0.2–0.8.
Using the operating-line-equation values, total V and L are calculated for different values of y and x in the tower

and converted to Gy  and Gx. Then values of   and   are calculated. If the variation between   or   at


the top and bottom of the tower is small, an average value can be used.

3. Starting with the tower bottom at point P1(y 1, x1), the interface compositions y i1, xi1 are determined by plotting a


line P1M1 with a slope calculated by Eq. (10.6-33). This line intersects the equilibrium line at the interface
concentrations at point M1:

Equation 10.6-33

where (1 − y)iM and (1 − x)iM are determined from Eqs. (10.4-6) and (10.4-7), respectively. This is trial and error.
As a first trial, (1 − x1) can be used for (1 − x)iM and (1 − y 1) for (1 − y)iM. The values of y i1 and xi1 determined in the
first trial are used in Eq. (10.6-33) for the second trial.

4 . At point P2(y 2, x2) determine a new slope using Eq. (10.6-33) and repeating step 3. Do this for several intermediate
points in the tower. This slope may vary throughout the tower.

5. Using the values of y i and xi, calculate the values of f(y) as follows:

Equation 10.7-1

Then numerically or graphically integrate Eq. (10.6-17) between y 2 and y 1 to obtain the tower height. If   or other


coefficients are used, the appropriate functions indicated in Eqs. (10.6-18)–(10.6-20) are used. If the stream is quite
dilute, (1 − y)iM or (1 − x)iM can be assumed to be 1.0.

EXAMPLE 10.7-1. Design of an Absorption Tower with a Concentrated Gas
Mixture
A tower packed with 25.4-mm ceramic rings is to be designed to absorb SO2 from air by using pure water at 293 K and 1.013

× 105 Pa abs pressure. The entering gas contains 20 mol % SO2 and that leaving 2 mol %. The inert air flow is 6.53 × 10−4 kg

mol air/s and the inert water flow is 4.20 × 10−2 kg mol water/s. The tower cross-sectional area is 0.0929 m2. For dilute SO2,
the film mass-transfer coefficients at 293 K are, for 25.4-mm (1-in.) rings (W1),
where   is kg mol/s · m3 · mol frac,   is kg mol/s · m3mol frac, and Gx and Gy  are kg total liquid or gas, respectively,

per sec per m2 tower cross section. Calculate the tower height.

S olu t ion: The given data are V' = 6.53 × 10−4 kg mol air/s (5.18 lb mol/h), L' = 4.20 × 10−2 kg mol/s (333 lb mol/h), y 1 =


0.20, y 2 = 0.02, and x2 = 0.

Substituting into the overall material-balance equation (10.6-4),

Solving, x1 = 0.00355. The operating line Eq. (10.6-5) is

Setting y = 0.04 in the operating-line equation above and solving for x, x = 0.000332. Selecting other values of y and solving
for x, points on the operating line were calculated as shown in Table 10.7-1 and plotted in Fig. 10.7-1 together with the
equilibrium data from Appendix A.3.

Table 10.7-1. Calculated Data for Example 10.7-1

(1 −
Y x V L Gy Gx xi yi 1 − y y)iM y − y i

0.02 0 6.66 0.04200 0.2130 8.138 0.03398 0.848 0.00046 0.0090 0.980 0.985 0.0110 19.25
×
10−4

0.04 0.000332 6.80 0.04201 0.2226 8.147 0.03504 0.849 0.00103 0.0235 0.960 0.968 0.0165 12.77
×
10−4

0.07 0.000855 7.02 0.04203 0.2378 8.162 0.03673 0.850 0.00185 0.0476 0.930 0.941 0.0224 9.29
×
10−4

0.13 0.00201 7.51 0.04208 0.2712 8.196 0.04032 0.853 0.00355 0.1015 0.870 0.885 0.0285 7.16
×
10−4

0.20 0.00355 8.16 0.04215 0.3164 8.241 0.04496 0.857 0.00565 0.1685 0.800 0.816 0.0315 6.33
×
10−4

Figure 10.7-1. Operating line and interface compositions for Example 10.7-1.

The total molar flow V is calculated from V = V'/(1 − y). At y = 0.20, V = 6.53 × 10−4/(1 − 0.2) = 8.16 × 10−4. Other values
are calculated and tabulated in Table 10.7-1. The total mass flow Gy  in kg/s · m2 is equal to the mass flow of air plus SO2
divided by the cross-sectional area:

Setting y = 0.20,

Similarly, Gy  is calculated for all points and tabulated. For the liquid flow, L = L'/(1 − x). Also, for the total liquid mass flow
rate,
Calculated values of L and Gx for various values of x are tabulated in Table 10.7-1.

To calculate values of  , for x = 0, Gx = 8.138 and

The rest of these values are calculated and given in Table 10.7-1. For the value of  , for y = 0.02, Gy  = 0.2130, Gx = 8.138,


and

This and other calculated values of   are tabulated. Note that these values vary considerably in the tower.

Next the interface compositions y i and xi must be determined for the given y and x values on the operating line. For the point
y 1 = 0.20 and x1 = 0.00355, we make a preliminary estimate of (1 − y)iM ≅ 1 − y ≅ 1 − 0.20 ≅ 0.80, together with the
estimate of (1 − x)iM ≅ 1 − x ≅ 1 − 0.00355 ≅ 0.996. The slope of the line P1M1 by Eq. (10.6-33) is approximately

Plotting this on Fig. 10.7-1, y i = 0.1688 and xi = 0.00566. Using these values for the second trial in Eqs. (10.4-6) and (10.4-
7),

The new slope by Eq. (10.6-33) is (−0.857/0.995)/(0.04496/0.816) = −15.6. Plotting, y i = 0.1685 and xi = 0.00565. This is
shown as point M1. This calculation is repeated until point y 2, x2 is reached. The slope of Eq. (10.6-33) increases markedly in
going up the tower, being −24.6 at the top of the tower. The values of y i and xi are given in Table 10.7-1.

In order to integrate Eq. (10.6-17), values of (1 − y), (1 − y)iM, and (y − y i) are needed and are tabulated in Table 10.7-1. Then
for y = 0.20, f(y) is calculated from Eq. (10.7-1):
This is repeated for other values of y from y 2 to y 1. Then the function f(y) is used to numerically integrate Eq. (10.6-17),
giving z = 1.588 m.
                             
                                                 
                                             
                                               
     

10.8. ESTIMATION OF MASS­TRANSFER COEFFICIENTS FOR
PACKED TOWERS

10.8A. Exp e r im e ntal De te r m ination of Film  C oe fficie nts

The individual film mass-transfer coefficients   and   depend generally upon Schmidt number, gas


and liquid mass velocities, and the size and shape of the packing. The interactions among these factors
are quite complex. Hence, the correlations for mass-transfer coefficients are highly empirical. The
reliability of these correlations is not too satisfactory. Deviations of up to 25% are not uncommon. A
major difficulty arises because it is an overall coefficient or resistance that is measured experimentally,
which represents the two film resistances in series. To obtain the single-phase film coefficient, the
experiment must be so arranged that the other film resistance is negligible or can be approximately
calculated.

To measure the liquid film mass-transfer coefficient  , a system for absorption or desorption of very

insoluble gases such as O2 or CO2 in water is used. The experiment gives  , which equals   (which


can give HL), since the gas-phase resistance is negligible.

To measure the gas-phase film coefficient  , we desire to use a system such that the solute is very
soluble in the liquid and the liquid-phase resistance is negligible. Most such systems, for example, NH3–
air–water, have a liquid-phase resistance of about 10%. By subtracting this known liquid-phase

resistance (obtained by correcting   data for absorption of CO2 or O2 to NH3 data for  ) from the

overall resistance in Eq. (10.4-24), we obtain the coefficient   or HG. Details of these systems are
discussed elsewhere (G1, S1, S2).

10.8B. C or r e lations for  Film  C oe fficie nts

Correlations for experimental coefficients can be expressed in terms of HL and HG or   and  , which


are related by Eqs. (10.6-39) and (10.6-40). For the first generation of packings, such as Raschig rings
and Berl saddles, extensive correlations are available (T1). However, comprehensive data on the
individual coefficients HL and HG for the newer packings, which have higher mass-transfer coefficients
and capacity, are not generally available. These newer packings are more commonly used today.

However, as an alternative method for comparing the performance of different types and sizes of these
newer random packings, the system CO2–air–NaOH solution is often used (P2, S4). Air containing 1.0
mole CO2 at 24°C (75°F) is absorbed in a packed tower using 1.0 N (4 wt %) NaOH solution (E2, E3, P2,
S4). An overall coefficient KGa is measured.

In this system, the liquid film is controlling but the gas film resistance is not negligible. The fast chemical
reaction between NaOH and CO2 takes place close to the interface, which gives a steeper concentration
gradient for CO2 in the water film. Hence, the value of KGa is muc h larger than for absorption of CO2 in
water. Because of this, these experimental values are not used to predict the absorption for other systems
in towers.

These experimental results, however, can be used to compare the performances of various packings. To

do this, the ratio fp of KGa for a given packing to that for  -in. Raschig rings at a liquid velocity Gx of

5000 lbm/h · ft 2 (6.782 kg/s · m2) and Gy  of 1000 lbm/h · ft 2 (1.356 kg/s · m2) is obtained; these are given


in Table 10.6-1. The fp value is a relative ratio of the total interfacial areas, since the reaction of CO2 in
NaOH solution takes place in the relatively static holdup pools and in the dynamic holdup. Some fp data

have been obtained at Gy  = 500 lbm/h · ft 2 instead of 1000 (E3). Eckert et al. (E2) showed that there is no

effect of Gy  in the range of 200–1000 lbm/h · ft 2 on the overall KGa. This is expected where the liquid film


resistance controls (S1). Values of fp for various investigators agree within ±10% or less.

10.8C . Pr e d icting M ass-Tr ansfe r  Film  C oe fficie nts

For estimating the performance HL(Hx) and HG(Hy ) of a new packing, the values of fp can be used to
correct the experimental Hx values for oxygen absorption or desorption and the Hy  value for NH3

absorption with  -in. Raschig rings. These values must also be corrected for Schmidt number, liquid
viscosity, and flow rates.

1. G a s film coefficient  H y

Using the NH3 absorption data corrected for the liquid film resistance of approximately 10%, HG has
been found to vary as Gy  to an exponent between 0.3 and 0.4 (S1, T1) for values of Gy  up to about 700

lbm/h · ft 2 (0.949 kg/s · m2). A value of 0.35 is used. For liquid flows of Gx from 500 to 5000 lbm/h · ft 2

(0.678–6.782 kg/s · m2), Hy  varies as  , with the value of   used. Also, the value of

Hy  has been found to be proportional to   of the gas phase. A value for Hy of 0.74 ft (0.226 m) is

obtained from the correlation for  -in. Raschig rings for the NH3 system (S1) corrected for the small
liquid film resistance of 10% at Gx = 5000 lbm/h · ft 2 (6.782 kg/s · m2) and Gy = 500 lbm/h · ft 2 (0.678

kg/s · m2). The value of Gy = 500 will be used instead of 1000, since there is no effect of Gy on fp in this
range. For the NH3 system, NSc = 0.66 at 25°C. Then, for estimation of HG for a new solute system and
packing and flow rates of Gx and Gy using SI units,

Equation 10.8-1

where fp for the new packing is given in Table 10.6-1 and HG is in m.

2. Liq u id  film coefficient  H x

For gas flow rates up to loading or about 50% of the flooding velocity, the effect of Gy  on Hx is small and

can be neglected (S1). Using the oxygen desorption data, Hx is proportional to the liquid  . The NSc

= 372 at 25°C for O2 in water and the viscosity μ is 0.8937 × 10−3 kg/m · s. Data for different packings

show that Hx is proportional to (Gx/μ) to the 0.22–0.35 exponent, with an average of (Gx/μ)0.3. A value

of Hx = 1.17 ft (0.357 m), where Gx = 5000 lbm/h · ft 2 is obtained from the correlation (S1) for the O2

system and  -in. Raschig rings. Then, to predict Hx for a new solute system and packing at velocities of
Gx and Gy  using SI units,

Equation 10.8-2

These equations can be used for values of Gy  up to almost 1000 lbm/h · ft 2 and Gx up to 5000 and remain


below loading.

EXAMPLE 10.8-1. Prediction of Film Coefficients for CO2
Absorption
Predict HG, HL, and HOL for absorption of CO2 from air by water in a dilute solution in a

packed tower with  -in. metal Pall rings at 303 K (30°C) and 101.32 kPa pressure. The flow
rates are Gx = 4.069 kg/s · m2 (3000 lbm/h · ft 2) and Gy  = 0.5424 kg/s · m2 (400 lbm/h · ft 2).
S olu t ion: From Appendix A.3-18, for CO2 at 1 atm, pA = 1.86 × 103xA. Hence, y A = pA/1.0 =

1.86 × 103xA (mole fraction units). Also, from Appendix A.3-3 for air at 303 K, μ = 1.866 ×

10−5 kg/m · s and the density ρ = 1.166 kg/m3. The diffusivity for CO2 at 276.2 K from Table

6.2-1 is 0.142 × 10−4 m2/s. Correcting this to 303 K by Eq. (6.2-45), DAB = 0.142 × 10−4

(303/276.2)1.75 = 0.1670 × 10−4 m2/s. Hence,

From Table 10.6-1 the relative mass-transfer coefficient for  -in. metal Pall rings compared to

that for  -in. Raschig rings is fp = 1.34. Substituting into Eq. (10.8-1),

From Appendix A.2-4, the viscosity of water at 303 K is 0.8007 × 10−3 kg/m · s and the
density ρ = 995.68 kg/m3. At 298 K the viscosity of water is 0.8937 × 10−3 kg/s · m.

From Table 6.3-1, the DAB of CO2 in water is 2.00 × 10−9 m2/s at 25°C. Using Eq. (6.3-9) to

correct it to 303 K, DAB = (0.8937 × 10−3/0.8007 × 10−3)(303/298) (2.00 × 10−9) = 2.270 ×

10−9 m2/s. Then,

Substituting into Eq. (10.8-2),

To calculate the value of HOL, the molar flow rates are calculated, where for dilute air, V =

Gy /MW = 0.5424/28.97 = 0.01872 kg mol/s · m2, and for water, L = Gx/MW = 4.069/18.0 =

0.2261 kg mol/s · m2. Substituting into Eq. (10.6-58),
The percent resistance in the gas film is 0.001575(100)/0.2322 = 0.68%. This shows that for a
very insoluble gas, even though HG is similar in value to HL, the large value of m causes the
gas-phase resistance to be very small. Hence, HOL ≅ HL. For a soluble gas like NH3, where m =

1.20 at 303 K compared to 1.86 × 103 for CO2, the percent resistance in the gas film would be
about 90%. (See Problem 10.8-1.) The different gas and liquid Schmidt numbers for NH3
would have only a small effect on the results.
10.9. HEAT EFFECTS AND TEMPERATURE VARIATIONS IN
ABSORPTION

10.9 A. He at Effe cts in Ab sor p tion

The temperature in an absorption tower can vary from the top to the bottom of the tower when the inlet
gas contains a relatively high concentration of solute. Solute absorption by the liquid yields a heat of
solution which raises the liquid temperature. Also, if evaporation of the solvent to the gas phase occurs,
the liquid temperature is cooled. The curvature of the equilibrium line depends upon the absorption of
the solute, the heat-transfer rate between phases, and the evaporation or condensation of the liquid
solvent.

Calculated temperature profiles may also have a maximum in the tower. This can occur when the
entering gas temperature is considerably below the exit solvent temperature and/or the volatile solvent
evaporates. Solvent evaporation cools the liquid near the tower bottom and a temperature maximum
occurs. Detailed rigorous heat and mass-balance equations are needed for mass transfer of the solute,
mass transfer of the solvent, heat transfer between the gas and liquid, and enthalpy balances. Equations
and examples are given by Sherwood et al. (S1), Stockar and Wilke (S7), and Treybal (T2). Note that in
actual towers, intercoolers are often used to keep the towers isothermal.

10.9 B. S im p lifie d  De sign M e thod

A simplified adiabatic design method is sometimes used when the entering gas contains solvent vapor
and/or solvent evaporation occurs. Heat of solution of the solute is also included in the design. Then,
using an overall enthalpy balance, the exit liquid temperature is calculated. This rise in liquid
temperature can then be used to adjust the equilibrium-line curvature. First, an overall enthalpy balance
is made which includes sensible heat for inlet and outlet gas temperatures, heat of solution of the solute,
heat of vaporization of the solvent, and sensible heat for the inlet and the unknown outlet liquid
temperature. This outlet temperature is then obtained.

The equilibrium line for the top entering liquid temperature is plotted, with the given slope at the dilute
concentration. Next, an equilibrium line at this higher outlet liquid temperature is plotted. The outlet
concentration x1 is then located on this equilibrium line. Then, assuming a linear liquid temperature
profile, the temperature of point x, which is halfway between the top and bottom concentrations, is
obtained. This x value is then located on the equilibrium line for this new temperature. The final curved
equilibrium line is plotted with the slope at the dilute end, through the x at the halfway point, and finally
through the x1 point. This method is illustrated in Example 10.9-1.

EXAMPLE 10.9­1. Heat Balance for Nonisothermal
Absorption Tower
The gas feed at 20°C and 1 atm to a packed absorption tower contains 6.0 mol % of NH3 (on a
dry basis) in air. The inlet gas is saturated with water vapor. The absorbing pure liquid water
enters at 25°C. The outlet gas contains 0.5% of NH3 on a dry basis; it is assumed to be
saturated with water vapor and leaves at 25°C. For a feed of 100 g mol dry gas, 190 g mol of
pure water are to be used for absorption. The heat of solution for 1.0 g mol NH3 gas absorbed in
water is ΔH = −8310 cal/g mol (S1). Equilibrium data (P1) are as follows for this system, where
y = mx:

S olu t ion: For the inlet gas, where y 1 = 0.06, the moles NH3 = 0.06(100) = 6.0 and moles air


= 0.94(100) = 94.0. For the outlet gas, where y 2 = 0.005, the moles air = 94.0 and moles NH3
= 94.0 [0.005/(1 − 0.005)] = 0.472. The total is 94.472 moles. The moles NH3 absorbed = 6.0
− 0.472 = 5.528. The outlet x1 = (5.528)/(190 + 5.528) = 0.0283. From Appendix A.2-9, the
latent heat of water at 25°C is (2442.3 J/g)(1/4.184 J/cal)(18.02 g/g mol) = 10 519 cal/g mol.
The vapor pressure of water at 20°C = 2.346 kPa and at 25°C, 3.169 kPa.

The moles H2O in the inlet gas at 20°C = (100.0)(2.346)/(101.325 − 2.346) = 2.370 moles
vapor. In the outlet gas moles H2O vapor = (94.472)(3.169)/(101.325 − 3.169) = 3.050 moles
vapor. The moles of H2O vaporized = 3.050 − 2.370 = 0.680.

An enthalpy balance is made for ammonia gas and air in and liquid water at 25°C. For air,
from Appendix A.3-3, cp = (1.0048 J/g · K)(1/4.184 J/cal) (28.972g/g mol) = 6.957 cal/g mol ·
K. For water vapor, from the Appendix, Fig. A.3-1, cp = 8.0 cal/g mol · K, and for NH3 gas, cp =
8.58 cal/g mol · K. The sensible heat for the entering gas at 20°C is as follows. For air, the
sensible heat q = 94(6.957)(20 − 25) = −3270 cal. For water vapor, q = (2.370)(8.0)(20 − 25) =
−95 cal. For NH3 gas, q = (6.00)(8.58)(20 − 25) = −257 cal. The total sensible heat is −3270 −
95 − 257 = −3622 cal. The latent heat of water vapor entering q = 2.370(10 519) = 24 930 cal.
The sensible heat of the entering liquid at 25°C is 0.

For the exit gas at 25°C, the sensible heat = 0. The latent heat of the water vapor = 3.050(10
519) = 32 083 cal. The heat of solution of NH3 absorption = 5.528(−8310) = −45 938 cal. From
Appendix A.2-11, assuming dilute liquid water, cp = (1.000 cal/g · K)(18.02 g/g mol) = 18.02
cal/g mol · K. The total g moles outlet liquid = 190 + 5.528 − 0.68 = 194.85. The sensible heat
q of the outlet liquid = (194.85)(18.02)(T1 − 25) = 3511(T1 − 25) cal, where T1 is the unknown
outlet temperature in °C. Equating the heat in to the heat out,

Solving, (T1 − 25) = 10.02°C, which is the temperature increase of the outlet liquid. The outlet
T1 = 35.02°C or 35°C.

In Fig. 10.9-1, a straight operating line is plotted since the solution is dilute. The equilibrium
line for 25°C is also shown with a slope m = 1.005 at the top of the tower. At the tower bottom,
at 35°C, the exit x1 = 0.0283. The equilibrium line at 35°C is shown. The point x1 is located on
this 35°C line and on the curved equilibrium line for the tower. The assumed linear
temperature profile is also shown. Selecting a value of x = (0 + 0.0283)/2 = 0.0142 with a
temperature of (35 + 25)/2 or 30°C, the point x1 = 0.0412 is plotted on the 30°C equilibrium
line. The final curved equilibrium line is plotted with a slope at the origin of 1.005 at 25°C,
through the point x = 0.0142 on the 30°C equilibrium line, and then through the point x1 =
0.0283 on the 35°C equilibrium line. Since the equilibrium line is curved, the number of overall
transfer units NOy  can be obtained by numerical or graphical integration as before using Eq.
(10.6-46).

Figure 10.9-1. Operating line and curved equilibrium line for Example 10.9-1. The calculated linear
temperature profile is also shown.
PROBLEMS
10.2-1.
Eq u ilib r iu m a nd  Henr y 's La w  C onst a nt . The partial pressure of CO2 in air is 1.333 × 104

Pa and the total pressure is 1.133 × 105 Pa. The gas phase is in equilibrium with a water solution
at 303 K. What is the value of xA for CO2 in equilibrium in the solution? See Appendix A.3 for the
Henry's law constant.
A1: Ans.  x  = 7.07 × 10−5 mol frac CO
A 2
10.2-2.
G a s S olu b ilit y  in Aq u eou s S olu t ion. At 303 K the concentration of CO2 in water is 0.90 ×

10−4 kg CO2/kg water. Using the Henry's law constant from Appendix A.3, what partial pressure
of CO2 must be kept in the gas to prevent the CO2 from vaporizing from the aqueous solution?
A2: Ans.  p  = 6.93 × 103 Pa (0.0684 atm)
A
10.2-3.
Pha se R u le for  a  G a s–Liq u id  S y st em. For the system SO2–air–water, the total pressure is
set at 1 atm abs and the partial pressure of SO2 in the vapor is set at 0.20 atm. Calculate the
number of degrees of freedom, F. What variables are unspecified and hence can be arbitrarily set?
10.3-1.
Eq u ilib ir u m S t a g e C ont a ct  for  G a s–Liq u id  S y st em. A gas mixture at 2.026 × 105 Pa
total pressure containing air and SO2 is brought into contact in a single-stage equilibrium mixer

with pure water at 293 K. The partial pressure of SO2 in the original gas is 1.52 × 104 Pa. The
inlet gas contains 5.70 total kg mol and the inlet water 2.20 total kg mol. The exit gas and liquid
leaving are in equilibrium. Calculate the amounts and compositions of the outlet phases. Use
equilibrium data from Fig. 10.2-1.
A4 :Ans. xA1 = 0.00495, y A1 = 0.0733, L1 = 2.211 kg mol, V1 = 5.69 kg mol
10.3-2.
Ab sor p t ion in a  C ou nt er cu r r ent  S t a g e Tow er . Repeat Example 10.3-2 using the same
conditions but with the following change. Use a pure water flow to the tower of 108 kg mol
H2O/h, that is, 20% above the 90 used in Example 10.3-2. Determine the number of stages
required graphically. Repeat, using the analytical Kremser equation.
10.3-3.
S t r ip p ing  Ta int  fr om C r ea m b y  S t ea m. Countercurrent stage stripping is to be used to
remove a taint from cream. The taint is present in the original cream to the stripper at a
concentration of 20 parts per million (ppm). For every 100 kg of cream entering per unit time, 50
kg of steam will be used for stripping. It is desired to reduce the concentration of the taint in the
cream to 1 ppm. The equilibrium relation between the taint in the steam vapor and the liquid
cream is y A = 10xA, where y A is ppm of taint in the steam and xA ppm in the cream (E1).
Determine the number of theoretical stages needed. [Hint: In this case, for stripping from the
liquid (L) stream to the vapor (V) stream, the operating line will be below the equilibrium line on
the y A − xA diagram. It is assumed that none of the steam condenses in the stripping. Use ppm
in the material balances.]
A6 :Ans. Number stages = 1.85 (stepping down starting from the concentrated end)
10.4 -1.Ov er a ll M a ss-Tr a nsfer  C oefficient  fr om Film C oefficient s. Using the same data as in

Example 10.4-1, calculate the overall mass-transfer coefficients   and Kx, the flux, and the
percent resistance in the gas film.

A7:  = 1.173 × 10  kg mol/s · m · mol frac,  = 1.519 × 10 ,   = 3.78 × 10  kg mol/s ·

Ans. −3 2 Kx −3 N −4
A
m2, 36.7% resistance
10.4 -2.
Int er fa ce C oncent r a t ions a nd  Ov er a ll M a ss-Tr a nsfer  C oefficient s. Use the same

equilibrium data and film coefficients   and   as in Example 10.4-1. However, use bulk


concentrations of y AG = 0.25 and xAL = 0.05. Calculate the following:

a. Interface concentrations y Ai and xAi and flux NA.

b. Overall mass-transfer coefficients  and Ky  and flux NA.

c. Overall mass-transfer coefficient   and flux NA.

10.5-1.
C ou nt er cu r r ent  W a t er -C ooling  Tow er . A forced-draft countercurrent water-cooling tower
is to cool water from 43.3 to 26.7°C. The air enters the bottom of the tower at 23.9°C with a wet
bulb temperature of 21.1°C. The value of HG for the flow conditions is HG = 0.533 m. The heat-
transfer resistance in the liquid phase will be neglected; that is, hL is very large. Hence, values of 

 should be used. Calculate the tower height needed if 1.5 times the minimum air rate is used.
10.5-2.
M inimu m G a s R a t e a nd  Heig ht  of W a t er -C ooling  Tow er . It is planned to cool water
from 110°F to 85°F in a packed countercurrent water-cooling tower using entering air at 85°F
with a wet bulb temperature of 75°F. The water flow is 2000 lbm/h · ft 2 and the air flow is 1400

lbm air/h · ft 2. The overall mass-transfer coefficient is KGa = 6.90 lb mol/h · ft 3atm.

a. Calculate the minimum air rate that can be used.

b. Calculate the tower height needed if the air flow of 1400 lbm air/h · ft 2 is used.

A10: Ans.  (a) G  = 935 lb air/h · ft 2 (4241 kg air/h · m2); (b) z = 21.8 ft (6.64 m)


min m
10.5-3.
Desig n of W a t er -C ooling  Tow er . Recalculate Example 10.5-1, but calculate the minimum
air rate and use 1.75 times the minimum air rate.
10.5-4 .
Effect  of C ha ng ing  Air  C ond it ions on C ooling  Tow er . For the cooling tower in Example
10.5-1, to what temperature will the water be cooled if the entering air enters at 29.4°C but the
wet bulb temperature is 26.7°C? The same gas and liquid flow rates are used. The water enters at
43.3°C, as before. (Hint: In this case TL1 is the unknown. The tower height is the same as in
Example 10.5-1. The slope of the operating line is as before. The solution is trial and error.
Assume a value of TL1 that is greater than 29.4°C. Do numerical or graphical integration to see if
the same height is obtained.)
10.6 -1.
Amou nt  of Ab sor p t ion in a  Tr a y  Tow er . An existing tower contains the equivalent of 3.0
theoretical trays and is being used to absorb SO2 from air by pure water at 293 K and 1.013 × 105

Pa. The entering gas contains 20 mol % SO2 and the inlet air flow rate is 150 kg inert air/h · m2.

The entering water rate is 6000 kg/h · m2. Calculate the outlet composition of the gas. (Hint:
This is a trial-and-error solution. Assume an outlet gas composition of, say, y 1 = 0.01. Plot the
operating line and determine the number of theoretical trays needed. If this number is not 3.0
trays, assume another value of y 1, and so on.)
A13:Ans. y 1 = 0.009
10.6 -2.
Ana ly t ica l M et hod  for  Nu mb er  of Tr a y s in Ab sor p t ion. Use the analytical equations in
Section 10.6 for countercurrent tray contact to calculate the number of theoretical trays needed

for Example 10.6-3 using 1.3 .
10.6 -3.
Ab sor p t ion of Ammonia  in a  Tr a y  Tow er . A tray tower is to be used to remove 99% of the
ammonia from an entering air stream containing 6 mol % ammonia at 293 K and 1.013 × 105 Pa.
The entering pure water flow rate is 188 kg H2O/h · m2and the inert air flow is 128 kg air/h · m2.
Calculate the number of theoretical trays needed. Use equilibrium data from Appendix A.3. For
the dilute end of the tower, plot an expanded diagram to step off the number of trays more
accurately.
A15:Ans. y 1 = 0.000639 (exit), xN  = 0.0260 (exit), 3.8 theoretical trays
10.6 -4 .
M inimu m Liq u id  Flow  in a  Pa ck ed  Tow er . The gas stream from a chemical reactor
contains 25 mol % ammonia and the rest inert gases. The total flow is 181.4 kg mol/h to an
absorption tower at 303 K and 1.013 × 105 Pa pressure, where water containing 0.005 mol frac
ammonia is the scrubbing liquid. The outlet gas concentration is to be 2.0 mol % ammonia.

What is the minimum flow  ? Using 1.5 times the minimum, plot the equilibrium and
operating lines.
A16 :  = 262.6 kg mol/h

Ans.
10.6 -5.
S t ea m S t r ip p ing  a nd  Nu mb er  of Tr a y s. A relatively nonvolatile hydrocarbon oil contains
4.0 mol % propane and is being stripped by direct superheated steam in a stripping tray tower to
reduce the propane content to 0.2%. The temperature is held constant at 422 K by internal
heating in the tower at 2.026 × 105 Pa pressure. A total of 11.42 kg mol of direct steam is used for
300 kg mol of total entering liquid. The vapor–liquid equilibria can be represented by y = 25x,
where y is mole fraction propane in the steam and x is mole fraction propane in the oil. Steam
can be considered as an inert gas and will not condense. Plot the operating and equilibrium lines
and determine the number of theoretical trays needed.
A17:Ans. 5.6 theoretical trays (stepping down from the tower top)
10.6 -6 .Ab sor p t ion of Ammonia  in Pa ck ed  Tow er . A gas stream contains 4.0 mol % NH3 and its

ammonia content is reduced to 0.5 mol % in a packed absorption tower at 293 K and 1.013 × 105
Pa. The inlet pure water flow is 68.0 kg mol/h and the total inlet gas flow is 57.8 kg mol/h. The

tower diameter is 0.747 m. The film mass-transfer coefficients are   = 0.0739 kg mol/s ·

m3mol frac and   = 0.169 kg mol/s · m3mol frac. Using the design methods for dilute gas
mixtures, do as follows:

a. Calculate the tower height using .

b. Calculate the tower height using .

A18:Ans. (a) z = 2.362 m (7.75 ft)
10.6 -7.
Tow er  Heig ht  Using  Ov er a ll M a ss-Tr a nsfer  C oefficient . Repeat Example 10.6-4, using

the overall liquid mass-transfer coefficient   to calculate the tower height.
10.6 -8.
Exp er iment a l Ov er a ll M a ss-Tr a nsfer  C oefficient . In a tower 0.254 m in diameter
absorbing acetone from air at 293 K and 101.32 kPa using pure water, the following experimental
data were obtained. Height of 25.4-mm Raschig rings = 4.88 m, V' = 3.30 kg mol air/h, y 1 =
0.01053 mol frac acetone, y 2 = 0.00072, L' = 9.03 kg mol water/h, x1 = 0.00363 mol frac
acetone. Calculate the experimental value of Ky a.
10.6 -9 .
C onv er sion t o Tr a nsfer -Unit  C oefficient s fr om M a ss-Tr a nsfer  C oefficient s.
Experimental data on absorption of dilute acetone in air by water at 80°F and 1 atm abs pressure
in a packed tower with 25.4-mm Raschig rings were obtained. The inert gas flow was 95 lbm

air/h · ft 2 and the pure water flow was 987 lbm/h · ft 2. The experimental coefficients are kGa =

4.03 lb mol/h · ft 3atm and kLa = 16.6 lb mol/h · ft 3 · lb mol/h · ft 3. The equilibrium data can be

expressed by cA = 1.37pA, where cA = lb mol/ft 3 and pA = atm partial pressure of acetone.

a. Calculate the film height of transfer units HG and HL.

b. Calculate HOG.

A21:Ans. HOG = 0.957 ft (0.292 m)
10.6 -
Heig ht  of Tow er  Using  Tr a nsfer  Unit s. Repeat Example 10.6-4 but use transfer units and
10.
calculate HL, NL, and tower height.
10.6 -
Exp er iment a l Va lu e of H OG . Using the experimental data given in Problem 10.6-8, calculate
11.
the number of transfer units NOG and the experimental value of HOG.
A23:Ans. HOG = 1.265 m
10.6 -
Pr essu r e Dr op  a nd  Tow er  Dia met er . Use the same conditions as in Example 10.6-1 but
12.
with the following changes. The gas feed rate is 2000 lbm/h and the design ratio of GL/GG is
2.2/1. Using 60% of flooding and 1 in Intalox packing, calculate the pressure drop, gas and
liquid flows, and tower diameter.
A24 :Ans. Δp = 0.250 in. water/ft packing, D = 1.452 ft (0.4425 m)
10.6 -
M inimu m Liq u id  Flow  R a t e in Ab sor p t ion. Using the data from Example 10.6-3,
13.
calculate the number of trays graphically and analytically for an operating flow rate of 1.3 times
the minimum liquid flow rate.
A25:Ans. N = 5.34 steps (analytical)
10.6 -
Exp er iment a l Heig ht  of Tr a nsfer  Unit  a nd  Ana ly t ica l Eq u a t ions. A packed tower 4.0
14 .
m tall is used to absorb ethyl alcohol from an inert gas by 90 kg mol/h of pure water at 303 K and
101.3 kPa. The total gas stream flow rate of 100 kg mol/h contains 2.0 mol % alcohol and the exit
concentration is 0.20 mol %. The equilibrium relation is y = mx = 0.68x for this dilute stream.
Using the analytical equations, calculate the number of theoretical trays N, the number of
transfer units NOG, HOG, and HETP.

A26 :Ans. HOG = 0.860 m (2.823 ft), N = 4.016 trays
10.7-1.
Liq u id  Film C oefficient s a nd  Desig n of S O 2  Tow er . Using the data for Example 10.7-1,
calculate the height of the tower using Eq. (10.6-18), which is based on the liquid film mass-

transfer coefficient .   [Note: The interface values xi have already been obtained.]
A27:Ans. z = 1.586 m
10.7-2.
Desig n of S O 2  Tow er  Using  Ov er a ll C oefficient s. Using the data for Example 10.7-1,

calculate the tower height using the overall mass-transfer coefficient .   [Hint: Calculate 

 at the top of the tower and at the bottom of the tower from the film coefficients. Then use a
linear average of the two values for the design. Obtain the values of y * from the operating- and

equilibrium-line plot. Numerically or graphically integrate Eq. (10.6-19), keeping   outside
the integral.]
10.7-3.
Heig ht  of Pa ck ed  Tow er  Using  Tr a nsfer  Unit s. For Example 10.7-1, calculate the tower
height using the HG and the number of transfer units NG. [Hint: Calculate HG at the tower top
using Eq. (10.6-39) and at the tower bottom. Use the linear average value for HG. Calculate the
number of transfer units NG by numerical or graphical integration of the integral of Eq. (10.6-
35). Then calculate the tower height.]
A29 :Ans. HG = 0.2036 m (average value)
10.7-4
Desig n of Ab sor p t ion Tow er  Using  Tr a nsfer  Unit s. The gas SO2 is being scrubbed from a

gas mixture by pure water at 303 K and 1.013 × 105 Pa. The inlet gas contains 6.00 mol % SO2

and the outlet 0.3 mol % SO2. The tower cross-sectional area of packing is 0.426 m2. The inlet
gas flow is 13.65 kg mol inert air/h and the inlet water flow is 984 kg mol inert water/h. The
mass-transfer coefficients are HL = 0.436 m and kGa = 6.06 × 10−7  kg mol/s · m3 · Pa and are to
be assumed constant in the tower for the given concentration range. Use equilibrium data from
Appendix A.3. By numerical or graphical integration, determine NG. Calculate the tower height.
(Note: The equilibrium line is markedly curved, so numerical or graphical integration is
necessary even for this dilute mixture.)
A30:Ans. NG = 8.47 transfer units, z = 1.311 m
10.8-1.
C or r ect ion of Film C oefficient s for  NH 3  Ab sor p t ion. Use the same system and conditions
given in Example 10.8-1, except that NH3 is being absorbed instead of CO2. The flow rates are
the same. Predict HG, HL, HOG, and percent resistance in the liquid phase.

A31:Ans. HOG = 0.2244 m, % resistance = 9.4%
10.8-2.
Pr ed ict ion of Film C oefficient s for  Acet one Ab sor p t ion. Predict HG, HL, and HOG for
absorption of acetone from air by water in a dilute aqueous solution using 2-in. Intalox metal
IMTP packing at 20°C and 1 atm abs pressure. The flow rates are Gx = 3.391 kg/s · m2 (2500

lbm/h · ft 2) and Gy  = 0.678 kg/s · m2 (500 lbm/h · ft 2). Use equilibrium data from Appendix A.3-


21 and the diffusivity for acetone in water from Table 6.3-1. The diffusivity of acetone in air at 1
atm abs is 0.109 × 10−4 m2/s at 0°C (P1).
A32:Ans. HG = 0.3416 m, HOG = 0.3921 m
10.9 -1.
Nonisot her ma l Ab sor p t ion Tow er . Use the same operating conditions as in Example 10.9-1
for absorption of NH3 except for the following change. The inlet gas temperature is 15°C and it is
saturated with water vapor. Calculate the outlet water temperature T1 and the overall number of
transfer units NOy  by numerical or graphical integration.
A33:Ans. T1 = 32.05°C
                             
                                                 
                                             
                                               
     

Chapter 11. Vapor–Liquid Separation Processes
                             
                                                 
                                             
                                               
     

11.1. VAPOR–LIQUID EQUILIBRIUM RELATIONS

11.1A. Phase  R u le  and  R aou lt's Law

As in the gas–liquid systems, the equilibrium in vapor–liquid systems is restricted by the phase rule, Eq.
(10.2-1). As an example we shall use the ammonia–water, vapor–liquid system. For two components
and two phases, F from Eq. (10.2-1) is 2 degrees of freedom. The four variables are temperature, pressure,
and the composition y A of NH3 in the vapor phase and xA in the liquid phase. The composition of water
(B) is fixed if y A or xA is specified, since y A + y B = 1.0 and xA + xB = 1.0. If the pressure is fixed, only one
more variable can be set. If we set the liquid composition, the temperature and vapor composition are
automatically set.

An ideal law, Raoult's law, can be defined for vapor–liquid phases in equilibrium:

Equation 11.1-1

where pA is the partial pressure of component A in the vapor in Pa (atm), PA is the vapor pressure of pure
A in Pa (atm), and xA is the mole fraction of A in the liquid. This law holds only for ideal solutions, such
as benzene–toluene, hexane–heptane, and methyl alcohol– ethyl alcohol, which are usually substances
very similar to each other. Many systems that are ideal or nonideal solutions follow Henry's law in dilute
solutions.

11.1B. Boiling-Point Diagr am s and  x-y  Plots

Often the vapor–liquid equilibrium relations for a binary mixture of A and B are given as a boiling-point
diagram, shown in Fig. 11.1-1 for the system benzene (A)–toluene (B) at a total pressure of 101.32 kPa.
The upper line is the saturated vapor line (the dew-point line) and the lower line is the saturated liquid
line (the bubble-point line). The two-phase region is in the region between these two lines.

Figure 11.1-1. Boiling point diagram for benzene (A)–toluene (B) at 101.325 kPa (1 atm ) total pressure.
In Fig. 11.1-1, if we start with a cold liquid mixture of xA1 = 0.318 and heat the mixture, it will start to boil
at 98°C (371.2 K), and the composition of the first vapor in equilibrium is y A1 = 0.532. As we continue
boiling, the composition xA will move to the left since y A is richer in A.

The system benzene–toluene follows Raoult's law, so the boiling-point diagram can be calculated from
the pure vapor-pressure data in Table 11.1-1 and the following equations:

Equation 11.1-2

Equation 11.1-3

Equation 11.1-4

Table 11.1-1. Vapor-Pressure and Equilibrium-Mole-Fraction Data for Benzene–Toluene System

Vapor Pressure
Mole Fraction
Benzene at 101.325
Temperature Benzene Toluene kPa

K °C kPa mm Hg kPa mm Hg xA yA

353.3 80.1 101.32 760     1.000 1.000


358.2 85 116.9 877 46.0 345 0.780 0.900
363.2 90 135.5 1016 54.0 405 0.581 0.777

368.2 95 155.7 1168 63.3 475 0.411 0.632


373.2 100 179.2 1344 74.3 557 0.258 0.456
378.2 105 204.2 1532 86.0 645 0.130 0.261

383.8 110.6 240.0 1800 101.32 760 0 0

EXAMPLE 11.1-1. Use of Raoult's Law for Boiling-Point
Diagram
Calculate the vapor and liquid compositions in equilibrium at 95°C (368.2 K) for benzene–
toluene using the vapor pressure from Table 11.1-1 at 101.32 kPa.

S olu t ion: At 95°C from Table 11.1-1 for benzene, PA = 155.7 kPa and PB = 63.3 kPa.
Substituting into Eq. (11.1-3) and solving,

Hence, xA = 0.411 and xB = 1 − xA = 1 − 0.411 = 0.589. Substituting into Eq. (11.1-4),

A common method of plotting the equilibrium data is shown in Fig. 11.1-2, where y A is plotted versus xA
for the benzene–toluene system. The 45° line is given to show that y A is richer in component A than is xA.

Figure 11.1-2. Equilibrium diagram for system benzene (A)–toluene (B) at 101.32 kPa (1 atm).
The boiling-point diagram in Fig. 11.1-1 is typical of an ideal system following Raoult's law. Nonideal
systems differ considerably. In Fig. 11.1-3a the boiling-point diagram is shown for a maximum-boiling
azeotrope. The maximum temperature Tmax corresponds to a concentration xAz and xAz = y Az at this
point. The plot of y A versus xA would show the curve crossing the 45° line at this point. Acetone–
chloroform is an example of such a system. In Fig. 11.1-3b a minimum-boiling azeotrope is shown with
y Az = xAz at Tmin . Ethanol–water is such a system.

Figure 11.1-3. Equilibrium boiling-point diagrams: (a) maximum-boiling azeotrope, (b) minimum-boiling
azeotrope.
                             
                                                 
                                             
                                               
     

11.2. SINGLE­STAGE EQUILIBRIUM CONTACT FOR VAPOR–LIQUID
SYSTEM
If a vapor–liquid system is being considered, where the stream V2 is a vapor and L0 is a liquid, and the
two streams are brought into contact in a single equilibrium stage which is quite similar to Fig. 10.3-1,
the boiling point or the x-y equilibrium diagram must be used, because an equilibrium relation similar to
Henry's law is not available. Since we are considering only two components, A and B, only Eqs. (10.3-1)
and (10.3-2) are used for the material balances. If sensible heat effects are small and the latent heats of
both compounds are the same, then when 1 mol of A condenses, 1 mol of B must vaporize. Hence, the
total moles of vapor V2 entering will equal V1 leaving. Also, moles L0 = L1. This case is called one of
constant molal overflow. An example is the benzene–toluene system.

EXAMPLE 11.2­1. Equilibrium Contact of Vapor–Liquid
Mixture
A vapor at the dew point and 101.32 kPa containing a mole fraction of 0.40 benzene (A) and
0.60 toluene (B) and 100 kg mol total is brought into contact with 110 kg mol of a liquid at the
boiling point containing a mole fraction of 0.30 benzene and 0.70 toluene. The two streams are
contacted in a single stage, and the outlet streams leave in equilibrium with each other.
Assume constant molal overflow. Calculate the amounts and compositions of the exit streams.

S olu t ion: The process flow diagram is the same as in Fig. 10.3-1. The given values are V2 =
100 kg mol, y A2 = 0.40, L0 = 110 kg mol, and xA0 = 0.30. For constant molal overflow, V2 = V1
and L0 = L1. Substituting into Eq. (10.3-2) to make a material balance on component A,

Equation 10.3-2

Equation 11.2-1

To solve Eq. (11.2-1), the equilibrium relation between y A1 and xA1 in Fig. 11.1-1 must be used.
This is by trial and error, since an analytical expression is not available that relates y A and xA.

First, we assume that xA1 = 0.20 and substitute into Eq. (11.2-1) to solve for y A1:

Solving, y A1 = 0.51. The equilibrium relations for benzene–toluene are plotted in Fig. 11.2-1. It
is evident that y A1 = 0.51 and xA1 = 0.20 do not fall on the curve. This point is plotted on the
graph. Next, assuming that xA1 = 0.40 and solving, y A1 = 0.29. This point is also plotted in
Fig. 11.2-1. Assuming that xA1 = 0.30, y A1 = 0.40. A straight line is drawn between these three
points which represents Eq. (11.2-1). At the intersection of this line with the equilibrium curve,
y A1 = 0.455 and xA1 = 0.25, which agree with Eq. (11.2-1).

Figure 11.2-1. Solution to Example 11.2-1.
                             
                                                 
                                             
                                               
     

11.3. SIMPLE DISTILLATION METHODS

11.3A. Intr od u ction

The separation process known as distillation is a method for separating the various components of a
liquid solution which depends upon the distribution of these components between a vapor phase and a
liquid phase. All components are present in both phases. The vapor phase is created from the liquid
phase by vaporization at the boiling point.

The basic requirement for the separation of components by distillation is that the composition of the
vapor be different from the composition of the liquid with which it is in equilibrium at the boiling point of
the liquid. Distillation is concerned with solutions where all components are appreciably volatile, such as
ammonia–water or ethanol–water solutions, where both components will be in the vapor phase. In
evaporation, by contrast, of a solution of salt and water, for example the water is vaporized but the salt is
not. The process of absorption differs from distillation in that one of the components in absorption is
essentially insoluble in the liquid phase. An example is absorption of ammonia from air by water, where
air is insoluble in the water–ammonia solution.

11.3B. R e lativ e  Volatility of Vap or –Liq u id  S yste m s

In Fig. 11.1-2, the equilibrium diagram for a binary mixture of A and B, the greater the distance between
the equilibrium line and the 45° line, the greater the difference between the vapor composition y A and
liquid composition xA. Hence, the separation is more easily made. A numerical measure of this
separation is the relative volatility αAB. This is defined as the ratio of the concentration of A in the vapor
to the concentration of A in the liquid divided by the ratio of the concentration of B in the vapor to the
concentration of B in the liquid:

Equation 11.3-1

where αAB is the relative volatility of A with respect to B in the binary system.

If the system obeys Raoult's law, as does the benzene–toluene system,

Equation 11.3-2

Substituting Eq. (11.3-2) into (11.3-1) for an ideal system,

Equation 11.3-3
Equation (11.3-1) can be rearranged to give

Equation 11.3-4

where α = αAB. When the value of α is above 1.0, a separation is possible. The value of α may change as
concentration changes. When binary systems follow Raoult's law, the relative volatility often varies only
slightly over a large concentration range at constant total pressure.

EXAMPLE 11.3-1. Relative Volatility for Benzene–Toluene
System
Using the data from Table 11.1-1, calculate the relative volatility for the benzene–toluene
system at 85°C (358.2 K) and 105°C (378.2 K).

S olu t ion: At 85°C, substituting into Eq. (11.3-3) for a system following Raoult's law,

Similarly at 105°C,

The variation in α is about 7%.

11.3C . Eq u ilib r iu m  or  Flash Distillation

1. Int r od u ct ion t o d ist illa t ion met hod s

Distillation can be carried out by either of two main methods in practice. The first method of distillation
involves the production of a vapor by boiling the liquid mixture to be separated in a single stage and
recovering and condensing the vapors. No liquid is allowed to return to the single-stage still to contact
the rising vapors. The second method of distillation involves the returning of a portion of the condensate
to the still. The vapors rise through a series of stages or trays, and part of the condensate flows downward
through the series of stages or trays countercurrent to the vapors. This second method is called fractional
distillation, distillation with reflux, or rectification.

There are three important types of distillation that occur in a single stage or still and that do not involve
rectification. The first of these is equilibrium or flash distillation, the second is simple batch or
differential distillation, and the third is simple steam distillation.

2. Eq u ilib r iu m or  fla sh d ist illa t ion

In equilibrium or flash distillation, which occurs in a single stage, a liquid mixture is partially vaporized.
The vapor is allowed to come to equilibrium with the liquid, and the vapor and liquid phases are then
separated. This can be done batchwise or continuously.

In Fig. 11.3-1 a binary mixture of components A and B flowing at the rate of F mol/h into a heater is
partially vaporized. Then the mixture reaches equilibrium and is separated. The composition of F is xF
mole fraction of A. A total material balance on component A is as follows:

Equation 11.3-5

Figure 11.3-1. Equilibrium or flash distillation.

Since L = F − V, Eq. (11.3-5) becomes

Equation 11.3-6

Usually, the moles per hour of feed F, moles per hour of vapor V, and moles per hour of L are known or
set. Hence, there are two unknowns x and y in Eq. (11.3-6). The other relationship needed in order to
solve Eq. (11.3-6) is the equilibrium line. A convenient method to use is to plot Eq. (11.3-6) on the x-y
equilibrium diagram. The intersection of the equation and the equilibrium line is the desired solution.
This is similar to Example 11.2-1 and shown in Fig. 11.2-1.

11.3D. S im p le  Batch or  Diffe r e ntial Distillation

In simple batch or differential distillation, liquid is first charged to a heated kettle. The liquid charge is
boiled slowly and the vapors are withdrawn as rapidly as they form to a condenser, where the condensed
vapor (distillate) is collected. The first portion of vapor condensed will be richest in the more volatile
component A. As vaporization proceeds, the vaporized product becomes leaner in A.
In Fig. 11.3-2 a simple still is shown. Originally, a charge of L1 moles of components A and B with a
composition of x1 mole fraction of A is placed in the still. At any given time, there are L moles of liquid
left in the still with composition x, and the composition of the vapor leaving in equilibrium is y. A
differential amount dL is vaporized.

Figure 11.3-2. Simple batch or differential distillation.

The composition in the still pot changes with time. In deriving the equation for this process, we assume
that a small amount of dL is vaporized. The composition of the liquid changes from x to x − dx and the
amount of liquid from L to L − dL. A material balance on A can be made, where the original amount = the
amount left in the liquid + the amount of vapor:

Equation 11.3-7

Multiplying out the right side,

Equation 11.3-8

Neglecting the term dx dL and rearranging,

Equation 11.3-9

Integrating,

Equation 11.3-10
where L1 is the original moles charged, L2 the moles left in the still, x1 the original composition, and x2
the final composition of liquid.

The equilibrium curve gives the relationship between y and x. The integration of Eq. (11.3-10) can be done
by calculating values of f(x) = 1/(y − x) and numerically or graphically integrating Eq. (11.3-10) between
x1 and x2. Equation (11.3-10) is known as the Rayleigh equation. The average composition of total
material distilled, y av , can be obtained by material balance:

Equation 11.3-11

EXAMPLE 11.3-2. Simple Differential Distillation
A mixture of 100 mol containing 50 mol % n-pentane and 50 mol % n-heptane is distilled
under differential conditions at 101.3 kPa until 40 mol is distilled. What is the average
composition of the total vapor distilled and the composition of the liquid left? The equilibrium
data are as follows, where x and y are mole fractions of n-pentane:

x y x y x y

1.000 1.000 0.398 0.836 0.059 0.271

0.867 0.984 0.254 0.701 0 0

0.594 0.925 0.145 0.521    

S olu t ion: The given values to be used in Eq. (11.3-10) are L1 = 100 mol, x1 = 0.50, L2 = 60
mol, and V (moles distilled) = 40 mol. Substituting into Eq. (11.3-10),

Equation 11.3-12

The unknown is x2, the composition of the liquid L2 at the end of the differential distillation.
To solve this by numerical integration, equilibrium values of y versus x are plotted so values of
y can be obtained from this curve at small intervals of x. Alternatively, instead of plotting, the
equilibrium data can be fitted to a polynomial function. For x = 0.594, the equilibrium value of
y = 0.925. Then f(x) = 1/(y − x) = 1/(0.925 − 0.594) = 3.02. Other values of f(y) are similarly
calculated.

The numerical integration of Eq. (11.3-10) is performed from x1 = 0.5 to x2 such that the
integral = 0.510 by Eq. (11.3-12) in Fig. 11.3-3. Hence, x2 = 0.277. Substituting into Eq. (11.3-
11) and solving for the average composition of the 40 mol distilled,

Figure 11.3-3. Numerical integration for Example 11.3-2.

11.3E. S im p le  S te am  Distillation

At atmospheric pressure high-boiling liquids cannot be purified by distillation, since the components of
the liquid may decompose at the high temperatures required. Often the high-boiling substances are
essentially insoluble in water, so a separation at lower temperatures can be obtained by simple steam
distillation. This method is often used to separate a high-boiling component from small amounts of
nonvolatile impurities.

If a layer of liquid water (A) and an immiscible high-boiling component (B) such as a hydrocarbon are
boiled at 101.3 kPa abs pressure, then, by the phase rule, Eq. (10.2-1), for three phases and two
components,

Hence, if the total pressure is fixed, the system is fixed. Since there are two liquid phases, each will exert
its own vapor pressure at the prevailing temperature and cannot be influenced by the presence of the
other. When the sum of the separate vapor pressures equals the total pressure, the mixture boils and

Equation 11.3-13

where PA is vapor pressure of pure water A and PB is vapor pressure of pure B. Then the vapor
composition is
Equation 11.3-14

As long as the two liquid phases are present, the mixture will boil at the same temperature, giving a
vapor of constant composition y A. The temperature is found by using the vapor-pressure curves for pure
A and pure B.

Note that by steam distillation, as long as liquid water is present, the high-boiling component B
vaporizes at a temperature well below its normal boiling point without using a vacuum. The vapors of
water (A) and high-boiling component (B) are usually condensed in a condenser and the resulting two
immiscible liquid phases separated. This method has the disadvantage that large amounts of heat must
be used to evaporate the water simultaneously with the high-boiling compound.

The ratio moles of B distilled to moles of A distilled is

Equation 11.3-15

Steam distillation is sometimes used in the food industry for the removal of volatile taints and flavors
from edible fats and oils. In many cases vacuum distillation is used instead of steam distillation to purify
high-boiling materials. The total pressure is quite low so that the vapor pressure of the system reaches
the total pressure at relatively low temperatures.

Van Winkle (V1) derives equations for steam distillation where an appreciable amount of a nonvolatile
component is present with the high-boiling component. This involves a three-component system. He
also considers other cases for binary batch, continuous, and multicomponent batch steam distillation.
                             
                                                 
                                             
                                               
     

11.4. DISTILLATION WITH REFLUX AND McCABE–THIELE
METHOD

11.4 A. Intr od u ction to Distillation w ith R e flu x

Rectification (fractionation) or stage distillation with reflux, from a simplified point of view, can be
considered to be a process in which a series of flash-vaporization stages are arranged in a series in such a
manner that the vapor and liquid products from each stage flow counter current to each other. The liquid
in a stage is conducted or flows to the stage below and the vapor from a stage flows upward to the stage
above. Hence, in each stage a vapor stream V and a liquid stream L enter, are mixed and equilibrated,
and a vapor and a liquid stream leave in equilibrium. This process flow diagram was shown in Fig. 10.3-1
for a single stage and an example given in Example 11.2-1 for a benzene–toluene mixture.

For the countercurrent contact with multiple stages in Fig. 10.3-2, the material-balance or operating-line
equation (10.3-13) was derived, which relates the concentrations of the vapor and liquid streams passing
each other in each stage. In a distillation column the stages (referred to as sieve plates or trays) in a
distillation tower are arranged vertically, as shown schematically in Fig. 11.4-1.

Figure 11.4-1. Process flow of a fr actionating tower containing sieve tr ays.


The feed enters the column in Fig. 11.4-1 somewhere in the middle of the column. If the feed is liquid, it
flows down to a sieve tray or stage. Vapor enters the tray and bubbles through the liquid on this tray as
the entering liquid flows across. The vapor and liquid leaving the tray are essentially in equilibrium. The
vapor continues up to the next tray or stage, where it is again contacted with a downflowing liquid. In
this case the concentration of the more volatile component (the lower-boiling component A) is being
increased in the vapor from each stage going upward and decreased in the liquid from each stage going
downward. The final vapor product coming overhead is condensed in a condenser and a portion of the
liquid product (distillate) is removed, which contains a high concentration of A. The remaining liquid
from the condenser is returned (refluxed) as a liquid to the top tray.

The liquid leaving the bottom tray enters a reboiler, where it is partially vaporized, and the remaining
liquid, which is lean in A or rich in B, is withdrawn as liquid product. The vapor from the reboiler is sent
back to the bottom stage or tray. Only three trays are shown in the tower of Fig. 11.4-1. In most cases the
number of trays is much greater. In the sieve tray the vapor enters through an opening and bubbles up
through the liquid to provide intimate contact between the liquid and vapor on the tray. In a theoretical
tray the vapor and liquid leaving are in equilibrium. The reboiler can be considered as a theoretical stage
or tray.

11.4 B. M cC ab e –Thie le  M e thod  of C alcu lation for  Nu m b e r  of The or e tical S tage s
1. Int r od u ct ion a nd  a ssu mp t ions

A mathematical–graphical method for determining the number of theoretical trays or stages needed for a
given separation of a binary mixture of A and B has been developed by McCabe and Thiele. The method
uses material balances around certain parts of the tower, which give operating lines somewhat similar to
Eq. (10.3-13), and the x-y equilibrium curve for the system.

The main assumption made in the McCabe–Thiele method is that there must be equimolar overflow
through the tower between the feed inlet and the top tray and the feed inlet and bottom tray. This is
shown in Fig. 11.4-2, where liquid and vapor streams enter a tray, are equilibrated, and leave. A total
material balance gives

Equation 11.4-1

Figure 11.4-2. Vapor and liquid flows entering and leaving a tray.

A component balance on A gives

Equation 11.4-2

where Vn+1 is mol/h of vapor from tray n + 1, Ln  is mol/h liquid from tray n, y n+1 is mole fraction of A in


Vn+1, and so on. The compositions y n  and xn  are in equilibrium and the temperature of the tray n is Tn . If
Tn  is taken as a datum, it can be shown by a heat balance that the sensible heat differences in the four
streams are quite small if heats of solution are negligible. Hence, only the latent heats in streams Vn+1
and Vn  are important. Since molar latent heats for chemically similar compounds are almost the same,
Vn+1 = Vn  and Ln  = Ln−1. Therefore, we have constant molal overflow in the tower.

2. Eq u a t ions for  enr iching  sect ion

In Fig. 11.4-3 a continuous-distillation column is shown, with feed being introduced to the column at an
intermediate point and an overhead distillate product and a bottoms product being withdrawn. The
upper part of the tower above the feed entrance is called the enriching section, since the entering feed of
binary components A and B is enriched in this section, so that the distillate is richer in A than the feed.
The tower is at steady state.

Figure 11.4-3. Distillation column showing material-balance sections for McCabe–Thiele method.

An overall material balance around the entire column in Fig. 11.4-3 states that the entering feed of F
mol/h must equal the distillate D in mol/h plus the bottoms W in mol/h:

Equation 11.4-3

A total material balance on component A gives

Equation 11.4-4

In Fig. 11.4-4a the distillation-tower section above the feed, the enriching section, is shown
schematically. The vapor from the top tray having a composition y 1 passes to the condenser, where it is
condensed so that the resulting liquid is at the boiling point. The reflux stream L mol/h and distillate D
mol/h have the same composition, so y 1 = xD. Since equimolal overflow is assumed, L1 = L2 = Ln  and V1
= V2 = Vn  = Vn+1.

Figure 11.4-4. Material balance and operating line for enriching section: (a) schematic of tower, (b) operating
and equilibrium lines.
Making a total material balance over the dashed-line section in Fig. 11.4-4a,

Equation 11.4-5

Making a balance on component A,

Equation 11.4-6

Solving for y n+1, the enriching-section operating line is

Equation 11.4-7

Since Vn+1 = Ln  + D, Ln /Vn+1 = R/(R + 1) and Eq. (11.4-7) becomes

Equation 11.4-8

where R = Ln /D = reflux ratio = constant. Equation (11.4-7) is a straight line on a plot of vapor
composition versus liquid composition. It relates the compositions of two streams passing each other
and is plotted in Fig. 11.4-4b. The slope is Ln /Vn+1 or R/(R + 1), as given in Eq. (11.4-8). It intersects the
y = x line (45° diagonal line) at x = xD. The intercept of the operating line at x = 0 is y = xD/(R + 1).
The theoretical stages are determined by starting at xD and stepping off the first plate to x1. Then y 2 is the
composition of the vapor passing the liquid x1. In a similar manner, the other theoretical trays are
stepped off down the tower in the enriching section to the feed tray.

3. Eq u a t ions for  st r ip p ing  sect ion

Making a total material balance over the dashed-line section in Fig. 11.4-5a for the stripping section of
the tower below the feed entrance,

Equation 11.4-9

Figure 11.4-5. Material balance and operating line for stripping section: (a) schematic of tower, (b) operating
and equilibrium lines.

Making a balance on component A,

Equation 11.4-10

Solving for y m+1, the stripping-section operating line is

Equation 11.4-11
Again, since equimolal flow is assumed, Lm = LN  = constant and Vm+1 = VN  = constant. Equation (11.4-
11) is a straight line when plotted as y versus x in Fig. 11.4-5b, with a slope of Lm/Vm+1. It intersects the y
= x line at x = xW. The intercept at x = 0 is y = −WxW/Vm+1.

Again the theoretical stages for the stripping section are determined by starting at xW, going up to y W,
and then across to the operating line, and so on.

4 . Effect  of feed  cond it ions

The condition of the feed stream F entering the tower determines the relation between the vapor Vm in the
stripping section and Vn  in the enriching section as well as between Lm and Ln . If the feed is part liquid
and part vapor, the vapor will add to Vm to give Vn .

For convenience, we represent the condition of the feed by the quantity q, which is defined as

Equation 11.4-12

If the feed enters at its boiling point, the numerator of Eq. (11.4-12) is the same as the denominator, and
q = 1.0. Equation (11.4-12) can also be written in terms of enthalpies:

Equation 11.4-13

where HV is the enthalpy of the feed at the dew point, HL the enthalpy of the feed at the boiling point
(bubble point), and HF the enthalpy of the feed at its entrance conditions. If the feed enters as vapor at
the dew point, q = 0. For cold liquid feed q > 1.0, for superheated vapor q < 0, and for the feed being part
liquid and part vapor, q is the fraction of feed that is liquid.

We can also look at q as the number of moles of saturated liquid produced on the feed plate by each mole
of feed added to the tower. In Fig. 11.4-6 a diagram shows the relationship between flows above and
below the feed extrance. From the definition of q, the following equations hold:

Equation 11.4-14

Equation 11.4-15

Figure 11.4-6. Relationship between flows above and below the feed entrance.
The point of intersection of the enriching and the stripping operating-line equations on an x-y plot can be
derived as follows. Rewriting Eqs. (11.4-6) and (11.4-10) as follows without the tray subscripts:

Equation 11.4-16

Equation 11.4-17

where the y and x values are the point of intersection of the two operating lines. Subtracting Eq. (11.4-16)
from (11.4-17),

Equation 11.4-18

Substituting Eqs. (11.4-4), (11.4-14), and (11.4-15) into Eq. (11.4-18) and rearranging,

Equation 11.4-19

This equation is the q-line equation and is the locus of the intersection of the two operating lines. Setting
y = x in Eq. (11.4-19), the intersection of the q-line equation with the 45° line is y = x = xF, where xF is the
overall composition of the feed.

In Fig. 11.4-7 the q line is plotted for various feed conditions given below the figure. The slope of the q line
is q/(q − 1). For example, for the liquid below the boiling point, q > 1, and the slope is >1.0, as shown.
The enriching and operating lines are plotted for the case of a feed of part liquid and part vapor, and the
two lines intersect on the q line. A convenient way to locate the stripping operating line is to first plot the
enriching operating line and the q line. Then draw the stripping line between the intersection of the q line
and enriching operating line and the point y = x = xW.

Figure 11.4-7. Location of the q line for various feed conditions: liquid below boiling point (q > 1), liquid at
boiling point (q = l), liquid + vapor (0 < q < 1), saturated vapor (q = 0).

5. Loca t ion of t he feed  t r a y  in a  t ow er  a nd  nu mb er  of t r a y s

To determine the number of theoretical trays needed in a tower, the stripping and operating lines are
drawn to intersect on the q line, as shown in Fig. 11.4-8. Starting at the top at xD, the trays are stepped
off. For trays 2 and 3, the steps can go to the enriching operating line, as shown in Fig. 11.4-8a. At step 4
the step goes to the stripping line. A total of about 4.6 theoretical steps are needed. The feed enters on
tray 4.

Figure 11.4-8. Method of stepping off number of theoretical trays and location of feed plate: (a) improper
location of feed on tray 4, (b) proper location of feed on tray 2 to give minimum number of steps.
For the correct method, the shift is made on step 2 to the stripping line, as shown in Fig. 11.4-8b. A total
of only about 3.7 steps are needed, with the feed on tray 2. To keep the number of trays to a minimum,
the shift from the enriching to the stripping operating line should be made at the first opportunity after
passing the operating-line intersection.

In Fig. 11.4-8b the feed is part liquid and part vapor, since 0 < q < 1. Hence, in adding the feed to tray 2,
the vapor portion of the feed is separated and added beneath plate 2 and the liquid added to the liquid
from above entering tray 2. If the feed is all liquid, it should be added to the liquid flowing to tray 2 from
the tray above. If the feed is all vapor, it should be added below tray 2 and join the vapor rising from the
plate below.

Since a reboiler is considered a theoretical step, when the vapor y W is in equilibrium with xW, as in Fig.
11.4-5b, the number of theoretical trays in a tower is equal to the number of theoretical steps minus one.

EXAMPLE 11.4-1. Rectification of a Benzene–Toluene
Mixture
A liquid mixture of benzene–toluene is to be distilled in a fractionating tower at 101.3 kPa
pressure. The feed of 100 kg mol/h is liquid, containing 45 mol % benzene and 55 mol %
toluene, and enters at 327.6 K (130°F). A distillate containing 95 mol % benzene and 5 mol %
toluene and a bottoms containing 10 mol % benzene and 90 mol % toluene are to be obtained.
The reflux ratio is 4:1. The average heat capacity of the feed is 159 kJ/kg mol · K (38 btu/lb mol
· °F) and the average latent heat 32 099 kJ/kg mol (13 800 btu/lb mol). Equilibrium data for
this system are given in Table 11.1-1 and Fig. 11.1-1. Calculate the kg moles per hour distillate,
kg moles per hour bottoms, and the number of theoretical trays needed.

S olu t ion: The given data are F = 100 kg mol/h, xF = 0.45, xD = 0.95, xW = 0.10, and R =
Ln /D = 4. For the overall material balance substituting into Eq. (11.4-3),

Equation 11.4-3
Substituting into Eq. (11.4-4) and solving for D and W,

Equation 11.4-4

For the enriching operating line, using Eq. (11.4-8),

The equilibrium data from Table 11.1-1 and the enriching operating line above are plotted in
Fig. 11.4-9.

Figure 11.4-9. McCabe–Thiele diagram for distillation of benzene–toluene for Example 11.4-1.

Next, the value of q is calculated. From the boiling-point diagram, Fig. 11.1-1, for xF = 0.45 the
boiling point of the feed is 93.5°C or 366.7 K (200.3°F). From Eq. (11.4-13),

Equation 11.4-13
The value of HV − HL = latent heat = 32 099 kJ/kg mol. The numerator of Eq. (11.4-13) is

Equation 11.4-20

Also,

Equation 11.4-21

where the heat capacity of the liquid feed cpL = 159 kJ/kg mol · K, TB = 366.7 K (boiling point
of feed), and TF = 327.6 K (inlet feed temperature). Substituting Eqs. (11.4-20) and (11.4-21)
into (11.4-13),

Equation 11.4-22

Substituting the known values into Eq. (11.4-22),

From Eq. (11.4-19), the slope of the q line is

The q line is plotted in Fig. 11.4-9 starting at the point y = xF = 0.45 with a slope of 6.12.

The stripping operating line is drawn connecting the point y = x = xW = 0.10 with the
intersection of the q line and the enriching operating line. Starting at the point y = x = xD, the
theoretical steps are drawn in, as shown in Fig. 11.4-9. The number of theoretical steps is 7.6,
or 7.6 steps minus a reboiler, which gives 6.6 theoretical trays. The feed is introduced on tray 5
from the top.

11.4 C . Total and  M inim u m  R e flu x R atio for  M cC ab e –Thie le  M e thod


1. Tot a l r eflu x

In distillation of a binary mixture A and B, the feed conditions, distillate composition, and bottoms
composition are usually specified and the number of theoretical trays are to be calculated. However, the
number of theoretical trays needed depends upon the operating lines. To fix the operating lines, the
reflux ratio R = Ln /D at the top of the column must be set.

One of the limiting values of reflux ratio is that of total reflux, or R = ∞. Since R = Ln /D and, by Eq. (11.4-
5),

Equation 11.4-5

then Ln  is very large, as is the vapor flow Vn . This means that the slope R/(R + 1) of the enriching


operating line becomes 1.0 and the operating lines of both sections of the column coincide with the 45°
diagonal line, as shown in Fig. 11.4-10.

Figure 11.4-10. Total reflux and minimum number of trays by McCabe–Thiele method.

The number of theoretical trays required is obtained as before by stepping off the trays from the distillate
to the bottoms. This gives the minimum number of trays that can possibly be used to obtain the given
separation. In actual practice, this condition can be realized by returning all the overhead condensed
vapor V1 from the top of the tower back to the tower as reflux, that is, total reflux. Also, all the liquid in
the bottoms is reboiled. Hence, all the products distillate and bottoms are reduced to zero flow, as is the
fresh feed to the tower.

This condition of total reflux can also be interpreted as requiring infinite sizes of condenser, reboiler, and
tower diameter for a given feed rate.

If the relative volatility α of the binary mixture is approximately constant, the following analytical
expression by Fenske can be used to calculate the minimum number of theoretical steps Nm when a total
condenser is used:

Equation 11.4-23

For small variations in α, αav  = (α1αW)1/2, where α1 is the relative volatility of the overhead vapor and
αW is the relative volatility of the bottoms liquid.

2. M inimu m r eflu x r a t io

The minimum reflux ratio can be defined as the reflux ratio Rm that will require an infinite number of
trays for the given desired separation of xD and xW. This corresponds to the minimum vapor flow in the
tower, and hence the minimum reboiler and condenser sizes. This case is shown in Fig. 11.4-11. If R is
decreased, the slope of the enriching operating line R/(R + 1) is decreased, and the intersection of this
line and the stripping line with the q line moves farther from the 45° line and closer to the equilibrium
line. As a result, the number of steps required to give a fixed xD and xW increases. When the two
operating lines touch the equilibrium line, a “pinch point” at y' and x' occurs, where the number of steps
required becomes infinite. The slope of the enriching operating line is as follows from Fig. 11.4-11, since
the line passes through the points x', y', and xD (y = xD):

Equation 11.4-24

Figure 11.4-11. Minimum reflux ratio and infinite number of trays by McCabe–Thiele method.
In some cases, where the equilibrium line has an inflection in it as shown in Fig. 11.4-12, the operating
line at minimum reflux will be tangent to the equilibrium line.

Figure 11.4-12. Minimum reflux ratio and infinite number of trays when operating line is tangent to equilibrium
line.

3. Op er a t ing  a nd  op t imu m r eflu x r a t io

For the case of total reflux, the number of plates is a minimum, but the tower diameter is infinite. This
corresponds to an infinite cost of tower as well as steam and cooling water. This is one limit in the tower
operation. Also, for minimum reflux, the number of trays is infinite, which again gives an infinite cost.
These are the two limits in operation of the tower.

The actual operating reflux ratio to use lies between these two limits. To select the proper value of R
requires a complete economic balance on the fixed costs of the tower and operating costs. The optimum
reflux ratio to use for lowest total cost per year is between the minimum Rm and total reflux. This has
been shown for many cases to be at an operating reflux ratio between 1.2Rm and 1.5Rm.

EXAMPLE 11.4-2. Minimum Reflux Ratio and Total Reflux
in Rectification
For the rectification in Example 11.4-1, where a benzene–toluene feed is being distilled to give
a distillate composition of xD = 0.95 and a bottoms composition of xW = 0.10, calculate the
following:

a.  Minimum reflux ratio Rm.

b.  Minimum number of theoretical plates at total reflux.

S olu t ion: For part (a), the equilibrium line is plotted in Fig. 11.4-13 and the q-line equation is
also shown for xF = 0.45. Using the same xD and xW as in Example 11.4-1, the enriching
operating line for minimum reflux is plotted as a dashed line and intersects the equilibrium
line at the same point at which the q line intersects. Reading off the values of x' = 0.49 and y' =
0.702, substituting into Eq. (11.4-24), and solving for Rm,

Figure 11.4-13. Graphical solution for minimum reflux ratio Rm  and total reflux for Example 11.4-2.
Hence, the minimum reflux ratio Rm = 1.17.

For the case of total reflux in part (b), the theoretical steps are drawn as shown in Fig. 11.4-13.
The minimum number of theoretical steps is 5.8, which gives 4.8 theoretical trays plus a
reboiler.

11.4 D. S p e cial C ase s for  R e ctification Using M cC ab e –Thie le  M e thod

1. S t r ip p ing -colu mn d ist illa t ion

In some cases the feed to be distilled is not supplied to an intermediate point in a column but is added to
the top of the stripping column, as shown in Fig. 11.4-14a. The feed is usually a saturated liquid at the
boiling point, and the overhead product VD is the vapor rising from the top plate, which goes to a
condenser with no reflux or liquid returned to the tower.

Figure 11.4-14. Material balance and operating line for stripping tower: (a) flows in tower, (b) operating and
equilibrium line.
The bottoms product W usually has a high concentration of the less volatile component B. Hence, the
column operates as a stripping tower, with the vapor removing the more volatile A from the liquid as it
flows downward. Assuming constant molar flow rates, a material balance of the more volatile component
A around the dashed line in Fig. 11.4-14a gives, on rearrangement,

Equation 11.4-25

This stripping-line equation is the same as the stripping-line equation for a complete tower given as Eq.
(11.4-11). It intersects the y = x line at x = xW, and the slope is constant at Lm/Vm+1.

If the feed is saturated liquid, then Lm = F. If the feed is cold liquid below the boiling point, the q line
should be used and q > 1:

Equation 11.4-26

In Fig. 11.4-14 the stripping operating-line equation (11.4-25) is plotted and the q line, Eq. (11.4-19), is
also shown for q = 1.0. Starting at xF, the steps are drawn down the tower.

EXAMPLE 11.4-3. Number of Trays in Stripping Tower
A liquid feed at the boiling point of 400 kg mol/h containing 70 mol % benzene (A) and 30 mol
% toluene (B) is fed to a stripping tower at 101.3 kPa pressure. The bottoms product flow is to
be 60 kg mol/h containing only 10 mol % A and the rest B. Calculate the kg mol/h overhead
vapor, its composition, and the number of theoretical steps required.

S olu t ion: Referring to Fig. 11.4-14a, the known values are F = 400 kg mol/h, xF = 0.70, W =
60 kg mol/h, and xW = 0.10. The equilibrium data from Table 11.1-1 are plotted in Fig. 11.4-15.
Making an overall material balance,

Figure 11.4-15. Stripping tower for Example 11.4-3.

Solving, VD = 340 kg mol/h. Making a component A balance and solving,

For a saturated liquid, the q line is vertical and is plotted in Fig. 11.4-15. The operating line is
plotted through the point y = xW = 0.10 and the intersection of y D = 0.806 with the q line.
Alternatively, Eq. (11.4-25) can be used, with a slope of Lm/Vm+1 = 400/340. Stepping off the
trays from the top, 5.3 theoretical steps or 4.3 theoretical trays plus a reboiler are needed.

2. Enr iching -colu mn d ist illa t ion


Enriching towers are also used at times, where the feed enters the bottom of the tower as a vapor. The
overhead distillate is produced in the same manner as in a complete fractionating tower and is usually
quite rich in the more volatile component A. The liquid bottoms is usually comparable to the feed in
composition, being slightly leaner in component A. If the feed is saturated vapor, the vapor in the tower
Vn  = F. Enriching-line equation (11.4-7) holds, as does the q-line equation (11.4-19).

3. R ect ifica t ion w it h d ir ect  st ea m inject ion

Generally, the heat to a distillation tower is applied to one side of a heat exchanger (reboiler) and the
steam does not come into direct contact with the boiling solution, as shown in Fig. 11.4-5. However,
when an aqueous solution of more volatile A and water B is being distilled, the heat required may be
provided by the use of open steam injected directly at the bottom of the tower. The reboiler exchanger is
then not needed.

The steam is injected as small bubbles into the liquid in the tower bottom, as shown in Fig. 11.4-16a. The
vapor leaving the liquid is then in equilibrium with the liquid if sufficient contact is obtained. Making an
overall balance on the tower and a balance on A,

Equation 11.4-27

Equation 11.4-28

Figure 11.4-16. Use of direct steam injection: (a) schematic of tower, (b) operating and equilibrium lines.
where S = mol/h of steam and y S = 0 = mole fraction of A in steam. The enriching operating-line equation
is the same as for indirect steam.

For the stripping-line equation, an overall balance and a balance on component A are as follows:

Equation 11.4-29

Equation 11.4-30

Solving for y m+1 in Eq. (11.4-30),

Equation 11.4-31

For saturated steam entering, S = Vm+1 and hence, by Eq. (11.4-29), Lm = W. Substituting into Eq. (11.4-
31), the stripping operating line is

Equation 11.4-32

When y = 0, x = xW. Hence, the stripping line passes through the point y = 0, x = xW, as shown in Fig.
11.4-16b, and is continued to the x axis. Also, for the intersection of the stripping line with the 45° line,
when y = x in Eq. (11.4-32), x = WxW/(W − S).

For a given reflux ratio and overhead distillate composition, the use of open steam rather than closed
requires an extra fraction of a stage, since the bottom step starts below the y = x line (Fig. 11.4-16b). The
advantage of open steam lies in simpler construction of the heater, which is a sparger.

4 . R ect ifica t ion t ow er  w it h sid e st r ea m

In certain situations, intermediate product or side streams are removed from sections of the tower
between the distillate and the bottoms. The side stream may be vapor or liquid and may be removed at a
point above the feed entrance or below, depending on the composition desired.

The flows for a column with a liquid side stream removed above the feed inlet are shown in Fig. 11.4-17.
The top enriching operating line above the liquid side stream and the stripping operating line below the
feed are found in the usual way. The equation for the q line is also unaffected by the side stream and is
found as before. The liquid side stream alters the liquid rate below it, and hence the material balance or
operating line in the middle portion between the feed and liquid side stream plates as well.

Figure 11.4-17. Process flow for a rectification tower with a liquid side stream.

Making a total material balance on the top portion of the tower, as shown in the dashed-line box in Fig.
11.4-17,

Equation 11.4-33

where O is mol/h saturated liquid removed as a side stream. Since the liquid side stream is saturated,

Equation 11.4-34

Equation 11.4-35

Making a balance on the most volatile component,

Equation 11.4-36
Solving for y S+1, the operating line for the region between the side stream and the feed is

Equation 11.4-37

The slope of this line is LS/VS+1. The line can be located as shown in Fig. 11.4-18 by the q line, which
determines the intersection of the stripping line and Eq. (11.4-37), or it may be fixed by the specification
of xO, the side-stream composition. The step on the McCabe–Thiele diagram must be at the intersection
of the two operating lines at xO in an actual tower. If this does not occur, the reflux ratio can be altered
slightly to change the steps.

Figure 11.4-18. McCabe–Thiele plot for a tower with a liquid side stream above the feed.

5. Pa r t ia l cond enser s

In a few cases it may be desired to remove the overhead distillate product as a vapor instead of a liquid.
This can also occur when the low boiling point of the distillate makes complete condensation difficult.
The liquid condensate in a partial condenser is returned to the tower as reflux and the vapor removed as
product, as shown in Fig. 11.4-19.

Figure 11.4-19. Partial condenser where the vapor and liquid leave in equilibrium: (a) process flow diagram,
(b) McCabe-Thiele plot.
If the time of contact between the vapor product and the liquid is sufficient, the partial condenser is a
theoretical stage. Then the composition xR of the liquid reflux is in equilibrium with the vapor
composition y D, where y D = xD. If the cooling in the condenser is rapid and the vapor and liquid do not
reach equilibrium, only a partial stage separation is obtained.
                             
                                                 
                                             
                                               
     

11.5. DISTILLATION AND ABSORPTION EFFICIENCIES FOR TRAY
AND PACKED TOWERS

11.5A. Tr ay Efficie ncie s

In all the previous discussions of theoretical trays or stages in distillation, we assumed that the vapor
leaving a tray was in equilibrium with the liquid leaving. However, if the time of contact and the degree of
mixing on the tray are insufficient, the streams will not be in equilibrium. As a result the efficiency of the
stage or tray will not be 100%. This means that we must use more actual trays for a given separation than
the theoretical number of trays determined by calculation. The discussions in this section apply to both
absorption and distillation tray towers.

Three types of tray or plate efficiency are used: overall tray efficiency EO, Murphree tray efficiency EM,
and point or local tray efficiency EMP (sometimes called Murphree point efficiency). These will be
considered individually.

11.5B. Typ e s of Tr ay Efficie ncie s

1. Ov er a ll t r a y  efficiency

The overall tray or plate efficiency EO concerns the entire tower and is simple to use, but it is the least
fundamental. It is defined as the ratio of the number of theoretical or ideal trays needed in an entire tower
to the number of actual trays used:

Equation 11.5-1

For example, if eight theoretical steps are needed and the overall efficiency is 60%, the number of
theoretical trays is eight minus a reboiler, or seven trays. The actual number of trays is 7/0.60, or 11.7
trays.

2. M u r p hr ee t r a y  efficiency

The Murphree tray efficiency EM is defined as follows:

Equation 11.5-2

where y n  is the average actual concentration of the mixed vapor leaving the tray n as shown in Fig. 11.5-1,
y n+1 the average actual concentration of the mixed vapor entering tray n, and   the concentration of the
vapor that would be in equilibrium with the liquid of concentration xn  leaving the tray to the downcomer.

Figure 11.5-1. Vapor and liquid compositions on a sieve tray and tray efficiency.

The liquid entering the tray has a concentration of xn−1; as it travels across the tray, its concentration
drops to xn  at the outlet. Hence, there is a concentration gradient in the liquid as it flows across the tray.
The vapor entering the tray comes in contact with liquid of different concentrations, and the outlet vapor
will not be uniform in concentration.

3. Point  efficiency

The point or local efficiency EMP on a tray is defined as

Equation 11.5-3

where   is the concentration of the vapor at a specific point in plate n as shown in Fig. 11.5-1,   the

concentration of the vapor entering the plate n at the same point, and   the concentration of the vapor

that would be in equilibrium with   at the same point. Since   cannot be greater than  , the local


efficiency cannot be greater than 1.00 or 100%.

In small-diameter towers, the vapor flow sufficiently agitates the liquid so that it is uniform on the tray.
Then the concentration of the liquid leaving is the same as that on the tray. Then  , 

and  . The point efficiency then equals the Murphree tray efficiency, or EM = EMP.

In large-diameter columns, incomplete mixing of the liquid occurs on the trays. Some vapor will contact
the entering liquid xn−1, which is richer in component A than xn . This will give a richer vapor at this
point than at the exit point, where xn  leaves. Hence, the tray efficiency EM will be greater than the point
efficiency EMP. The value of EM can be related to EMP by integration of EMP over the entire tray.

11.5C . R e lationship  Be tw e e n Tr ay Efficie ncie s

The relationship between EMP and EM can be derived mathematically if the amount of liquid mixing is
specified together with the amount of vapor mixing. Derivations for three different sets of assumptions
are given by Robinson and Gilliland (R1). However, experimental data are usually needed to obtain
amounts of mixing. Semitheoretical methods for predicting EMP and EM are summarized in detail by
Van Winkle (V1).

When the Murphree tray efficiency EM is known or can be predicted, the overall tray efficiency EO can be
related to EM by several methods. In the first method, an analytical expression is as follows when the
slope m of the equilibrium line is constant as well as the slope L/V of the operating line:

Equation 11.5-4

If the equilibrium and operating lines of the tower are not straight, a graphical method employing the
McCabe–Thiele diagram can be used to determine the actual number of trays when the Murphree tray
efficiency is known. In Fig. 11.5-2 a diagram is given for an actual plate as compared with an ideal plate.
The triangle acd represents an ideal plate and the smaller triangle abe the actual plate. For the case
shown, the Murphree efficiency EM = 0.60 = ba/ca. The dashed line going through point b is drawn so
that ba/ca for each tray is 0.60. The trays are stepped off using this efficiency, and the total number of
steps gives the actual number of trays needed. The reboiler is considered to be one theoretical tray, so the
true equilibrium curve is used for this tray, as shown. In Fig. 11.5-2, 6.0 actual trays plus a reboiler are
obtained.

Figure 11.5-2. Use of Murphree plate efficiency to determine actual number of trays.
11.5D. Efficie ncy of R and om -Packe d  and  S tr u ctu r e d  Packe d  Tow e r s

In tray towers, a theoretical tray is defined as a tray in which equilibrium is attained between the gas or
vapor leaving and the liquid leaving the tray. In random-packed or structured packed towers, the same
approach is used, where the HETP in m (ft) is defined as the height of the packed column necessary to
give a separation equal to one theoretical plate. The design of mass-transfer towers requires evaluation of
the number of theoretical stages or transfer units. Hence, the height of packing H in m (ft) required to
perform a given separation is

Equation 11.5-5

where n is the number of theoretical stages needed. Using the number-of-transfer-units method, the
height H is

Equation 11.5-6

where HOG is the overall height of a transfer unit in m (ft) and NOG is the number of transfer units.

The HETP and overall height of a transfer unit HOG can be related by the following equation, which is the
same as Eq. (10.6-55):

Equation 11.5-7
where m is the slope of the equilibrium line in mole fraction units and L and V are molar flow rates. If the
operating line and equilibrium line are parallel, then HETP = HOG. In distillation, the operating and
equilibrium lines diverge below the feed point and converge above, so that the average mV/L is about 1.0
and HETP ≅ HTU for distillation. This is usually not true for absorption or stripping towers. Although
the HETP concept lacks a sound theoretical basis, unlike the mass-transfer and HOG concepts, it is
simple and easy to use in computer equilibrium stage-to-stage calculations in distillation and is widely
used to estimate packing height (S3). It is especially useful in multicomponent systems.

For a tray tower, the HETP can be defined as

Equation 11.5-8

where E0 is the overall tray efficiency and T is the tray spacing, which varies from about 0.3 m for a 0.5-
m-diameter tower, 0.6 m for a 1.0-m-diameter tower, to about 0.8 m (2.6 ft) for much larger towers over
4 m in diameter.

11.5E. Estim ation of Efficie ncie s of Tr ay and  Packe d  Tow e r s

In order to design the number of trays or packing heights needed, efficiencies must be obtained.

1. Efficiency  of t r a y  t ow er s

For estimating the overall tray efficiency of bubble-tray towers for distillation, the O'Connell (O1)
correlation can be used (K2) with about a ±10% error. The following equation for these data from Lockett
(L1) can be used for sieve and valve trays as well, but predictions will be slightly conservative:

Equation 11.5-9

where E0 is fraction efficiency, α is relative volatility of the two key components at the average tower
temperature, and μL is the molar average viscosity in cp of the liquid feed at the average tower
temperature of the top and the bottom. Most typical efficiencies are between 40 and 80%.

To estimate the overall tray efficiency for absorption towers, the O'Connell correlation (O1) can be used.
This correlation is represented by the equation (S3)

Equation 11.5-10
where E0 is overall average % tray efficiency, ML is the average molecular weight of the liquid, m is the

slope of the equilibrium line in mole fraction units, ρL is the liquid density in lbm/ft 3, and μL is molar
average liquid viscosity in cp at the average tower temperature. The average deviation of the data is
±16.3% and the maximum is 157%. This can be used for bubble-cap, sieve, and valve-type trays. Note
that these tray efficiencies are quite low and in the range of 1% to 50%, with typical values of 10 to 30%.

2. Efficiency  of r a nd om-p a ck ed  t ow er s

For estimates for random packing, Eq. (11.5-11) can be used to determine the HETP for second- and
third-generation packings only (S2):

Equation 11.5-11

where HETP is in m and dp is packing diameter in mm. In English units, HETP is in ft and dp is in in.
Also, for small-diameter towers, where the tower diameter D is less than 0.60 m (2 ft), HETP = D, but not
less than 0.3 m (1 ft).

For vacuum service (S3),

Equation 11.5-12

The above equations are useful for low-viscosity liquids. For absorption with high-viscosity liquids, the
values of HETP are much greater, with values of 1.5 to 1.8 m (5 to 6 ft).

3. Efficiency  of st r u ct u r ed  p a ck ing  in t ow er s

For approximate estimates of the efficiency of structured packings at low to moderate pressure with low
viscosity liquids (K4),

Equation 11.5-13

where HETP is in m and a is surface area in m2/m3. In English units, HETP is in ft and a in ft 2/ft 3. The


value added of 0.10 m gives the estimate a conservative bias (K4). Values of HETP range from about 0.3
to 0.6 m (1.0 to 2.0 ft). For wire mesh (gauze), structured-packing values range from 0.1 to 0.3 m (0.3 to
1.0 ft).

EXAMPLE 11.5-1. Estimation of Tray and Packing
Efficiencies and Tower Height
A liquid feed of benzene–toluene is being distilled under the same conditions as in Ex. 11.4-1.
The number of theoretical steps needed is calculated as 7.6. The feed composition xF = 0.45,
xD = 0.95, and xW = 0.10. Do as follows:

a.  Using valve trays, calculate the overall efficiency E0 and the tower height. Assume a
tray spacing T of 0.6 m.

b.  Using 2-in. metal Pall rings, calculate the HETP and the tower height.

c.  Using Flexipac No. 2 structured packing, calculate the tower height.

S olu t ion: For part (a), from Fig. 11.1-1 at 1 atm abs and xW = 0.10, the boiling temperature is
106.5°C. At the top, for xD = 0.95, the dew point is 82.3°C. The average is (106.5 + 82.3)/2 or
94.4°C.

Using Table A.3-12 and Fig. A.3-4 at 94.4°C, the viscosity of benzene is 0.26 cp, and of
toluene, 0.295 cp. The molar average viscosity is μL = 0.45(0.26) + 0.55(0.295) = 0.279 cp.

From Table 11.1-1, the vapor pressure of benzene PA at 94.4°C is 153.3 kPa, and for toluene, PB
= 62.2 kPa. Hence, the average relative volatility α = 153.3/62.2 = 2.465.

Using Eq. (11.5-9), E0 = 0.492(μLα)−0.245 = 0.492 (0.279 × 2.465)−0.245 = 0.539. Using Eq.
(11.5-8), HETP = T/E0 = 0.6/0.539 = 1.113 m/theoretical steps. The number of tray theoretical
steps = 7.6 − 1 step for the reboiler, or 6.6 steps. Hence, tower tray height H = 1.113(6.6) =
7.35 m.

For part (b), for 2-in. (25.4 × 2 mm) Pall rings, Eq. (11.5-11) gives

For 6.6 theoretical steps, tower height H = 0.914(6.6) = 6.03 m.

For part (c), for Flexipac No. 2 structured packing and using Table 10.6-1, a = 223 m/m2.
From Eq. (11.5-13),

11.5F. Flood ing Ve locity and  Diam e te r  of Tr ay Tow e r s

In tray towers the maximum vapor velocity can be limited either by entrainment of small liquid droplets
or by the liquid handling capacity of the tray downcomer whereby the liquid in the downcomer backs up
to the next tray. The general basis for design uses the allowable-vapor-velocity concept. The equation by
Fair (F1) for estimating the maximum allowable vapor velocity for sieve, bubble-cap, or valve trays is

Equation 11.5-14
where νmax is the allowable vapor velocity in ft/s based on the total cross-sectional area minus the area of
one downcomer, σ is the surface tension of the liquid in dyn/cm (mN/m), and ρL and ρV are liquid and

gas densities, kg/m3 or lbm/ft 3. The value of Kν  in ft/s is obtained from Fig. 11.5-3, where L and V are


total flow rates in kg/h or lbm/h. As a rule-of-thumb, the value of Kν  should be multiplied by a factor of
0.91 to account for the downspout area of 9% of the tray (T2).

Figure 11.5-3. Estimation of K ν  value for allowable vapor velocity. (From Fair, J. R., Petro/Chem. Eng., 33(10),

45 (1961). With permission.)

The Eq. (11.5-14) holds for nonfoaming systems. For many absorbers the Kν  should be multiplied by 0.90
or so to account for foaming (S3). For the final design the above νmax should be multiplied by 0.80 to be
20% below flooding. For organic liquids a typical value of σ is about 20–25 dyn/cm. For water with a
surface tension of about 72 dyn/cm, the flooding velocity is larger by a factor of about (72/22.5)0.20, or
1.26/1.

EXAMPLE 11.5-2. Tray Diameter of a Valve-Tray
Absorption Tower
A valve-tray absorption tower is being used to absorb and recover ethyl alcohol vapor in air by
pure water. The tower operates at 30°C and a pressure of 110 kPa abs. The entering gas
contains 2.0 mol % ethyl alcohol in water, and 95% of the alcohol is recovered in the outlet
water. The inlet pure aqueous flow is 186 kg mol/h and the inlet gas flow is 211.7 kg mol/h.
Calculate the required tower diameter. A tray spacing of 0.610 m (2.0 ft) will be assumed. Use
a factor of 0.95 for possible foaming.
S olu t ion: The molecular weight of the entering air at the tower bottom where the flow rates
are the greatest is

The density of the vapor is

The mass flow rate of the gas is V = 211.7(29.34) = 6211 kg/h. Moles ethyl alcohol absorbed =
0.95(0.02)(211.7) = 4.02. The outlet aqueous flow rate L = 186.0 + 4.02 = 190.02 kg mol/h.
The liquid mass flow rate is

The outlet water density, assuming a dilute solution at 30°C, from Appendix A.2-3 is ρL =

0.995(1000) = 995 kg/m3. Then,

Using Fig. 11.5-3 for a 24-in. tray spacing, Kν  = 0.385 ft/s. Substituting into Eq. (11.5-14) and
using a surface tension of 70 (slightly less than water),

Multiplying the above by 0.91 to account for downspout area, by 0.95 for foaming, and by
0.80 for 80% of flooding,

The tower cross-section equals
Solving for the diameter, πD2/4 = 0.464. Then, D = 0.7686 m (2.522 ft).
                             
                                                 
                                             
                                               
     

11.6. FRACTIONAL DISTILLATION USING ENTHALPY–
CONCENTRATION METHOD

11.6 A. Enthalp y–C once ntr ation Data

1. Int r od u ct ion

In Section 11.4B the McCabe–Thiele method was used to calculate the number of theoretical steps or
trays needed for a given separation of a binary mixture of A and B by rectification or fractional
distillation. The main assumptions in the method are that the latent heats are equal, sensible heat
differences are negligible, and constant molal overflow occurs in each section of the distillation tower. In
this section we shall consider fractional distillation using enthalpy–concentration data where the molal
overflow rates are not necessarily constant. The analysis will be made using enthalpy as well as material
balances.

2. Ent ha lp y –concent r a t ion d a t a

An enthalpy–concentration diagram for a binary vapor– liquid mixture of A and B takes into account
latent heats, heats of solution or mixing, and sensible heats of the components of the mixture. The
following data are needed to construct such a diagram at a constant pressure: (1) heat capacity of the
liquid as a function of temperature, composition, and pressure; (2) heat of solution as a function of
temperature and composition; (3) latent heats of vaporization as a function of composition and pressure
or temperature; and (4) boiling point as a function of pressure, composition, and temperature.

The diagram at a given constant pressure is based on arbitrary reference states of liquid and temperature,
such as 273 K (32°F). The saturated liquid line in enthalpy h kJ/kg (btu/lbm) or kJ/kg mol is calculated
by

Equation 11.6-1

where xA is wt or mole fraction A, T is boiling point of the mixture in K (°F) or °C, T0 is reference
temperature, K, cpA is the liquid heat capacity of the component A in kJ/kg · K (btu/lbm · °F) or kJ/kg
mol · K, cpB is heat capacity of B, and ΔHsol is heat of solution at T0 in kJ/kg (btu/lbm) or kJ/kg mol. If
heat is evolved on mixing, the ΔHsol will be a negative value in Eq. (11.6-1). Often, the heats of solution
are small, as in hydrocarbon mixtures, and are neglected.

The saturated vapor enthalpy line of H kJ/kg (btu/lbm) or kJ/kg mol of a vapor composition y A is
calculated by

Equation 11.6-2
where   is the vapor heat capacity for A and   for B. The latent heats λ A and λ B are the values at
the reference temperature T0. Generally, the latent heat is given as λ Ab at the normal boiling point TbA of
the pure component A and λ Bb for B. Then to correct this to the reference temperature T0 for use in Eq.
(11.6-2),

Equation 11.6-3

Equation 11.6-4

In Eq. (11.6-3) the pure liquid is heated from T0 to TbA, vaporized at TbA, and then cooled as a vapor to
T0. Similarly, Eq. (11.6-4) also holds for λ B. For convenience, the reference temperature T0 is often taken
as equal to the boiling point of the lower-boiling component A. This means λ A = λ Ab. Hence, only λ Bb
must be corrected to λ B.

EXAMPLE 11.6-1. Enthalpy–Concentration Plot for
Benzene–Toluene
Prepare an enthalpy–concentration plot for benzene–toluene at 1 atm pressure. Equilibrium
data are given in Table 11.1-1 and Figs. 11.1-1 and 11.1-2. Physical property data are given in
Table 11.6-1.

Table 11.6-1. Physical Property Data for Benzene and Toluene

Heat Capacity, (kJ/kg
mol · K) Latent Heat of
Vaporization (kJ/kg
Component Boiling Point, (°C) Liquid Vapor mol)

Benzene (A) 80.1 138.2 96.3 30 820


Toluene (B) 110.6 167.5 138.2 33 330

S olu t ion: A reference temperature of T0 = 80.1°C will be used for convenience so that the
liquid enthalpy of pure benzene (xA = 1.0) at the boiling point will be zero. For the first point,
we will select pure toluene (xA = 0). For liquid toluene at the boiling point of 110.6°C, using
Eq. (11.6-1) with zero heat of solution and data from Table 11.6-1,

Equation 11.6-5
For the saturated vapor enthalpy line, Eq. (11.6-2) is used. However, we must first calculate λ B
at the reference temperature T0 = 80.1°C, using Eq. (11.6-4):

Equation 11.6-4

To calculate H, Eq. (11.6-2) is used, and y A = 0:

Equation 11.6-2

For pure benzene, xA = 1.0 and y A = 1.0. Using Eq. (11.6-5), since T = T0 = 80.1, h = 0. For the
saturated vapor enthalpy, using Eq. (11.6-2) and T = 80.1,

Selecting xA = 0.50, the boiling point Tb = 92°C and the temperature of saturated vapor for y A
= 0.50 is 98.8°C from Fig. 11.1-1. Using Eq. (11.6-5) for the saturated liquid enthalpy at the
boiling point,

Using Eq. (11.6-2) for y A = 0.5, the saturated vapor enthalpy at 98.8°C is

Selecting xA = 0.30 and y A = 0.30, h = 2920 and H = 36 268. Also, for xA = 0.80 and y A =


0.80, h = 562 and H = 32 380. These values are tabulated in Table 11.6-2 and plotted in Fig.
11.6-1.

Figure 11.6-1. Enthalpy-concentration plot for benzene-toluene mixture at 1.0 atm abs.

Table 11.6-2. Enthalpy–Concentration Data for Benzene–Toluene Mixtures at 101.325 kPa (1 atm)
Total Pressure

Saturated Liquid Saturated Vapor

Mole fraction, x A Enthalpy, h, (kJ/kg mol) Mole fraction, y A enthalpy, H, (kJ/kg mol)

0 5109 0 38 439
0.30 2920 0.30 36 268

0.50 1820 0.50 34 716


0.80 562 0.80 32 380

1.00 0 1.00 30 820

Some properties of the enthalpy–concentration plot are as follows. The region in between the saturated
vapor line and the saturated liquid line is the two-phase liquid–vapor region. From Table 11.1-1, for xA =
0.411, the vapor in equilibrium is y A = 0.632. These two points are plotted in Fig. 11.6-1; this tie line
represents the enthalpies and compositions of the liquid and vapor phases in equilibrium. Other tie lines
can be drawn in a similar manner. The region below the h-versus-xA line represents liquid below the
boiling point.

11.6 B. Distillation in Enr iching S e ction of Tow e r


To analyze the enriching section of a fractionating tower using enthalpy–concentration data, we make an
overall and a component balance in Fig. 11.6-2:

Equation 11.6-6

Equation 11.6-7

Figure 11.6-2. Enriching section of distillation tower.

Equation (11.6-7) can be rearranged to give the enriching-section operating line:

Equation 11.6-8

This is the same as Eq. (11.4-7) for the McCabe–Thiele method, but now the liquid and vapor flow rates
Vn+1 and Ln  may vary throughout the tower, and Eq. (11.6-8) will not be a straight line on an x-y plot.

Making an enthalpy balance,

Equation 11.6-9
where qc is the condenser duty, kJ/h or kW (btu/h). An enthalpy balance can be made just around the
condenser:

Equation 11.6-10

By combining Eqs. (11.6-9) and (11.6-10) to eliminate qc, an alternative form is obtained:

Equation 11.6-11

Substituting the value of Ln  from Eq. (11.6-6) into (11.6-11),

Equation 11.6-12

Equations (11.6-8) and (11.6-12) are the final working equations for the enriching section.

In order to plot the operating line Eq. (11.6-8), the terms Vn+1 and Ln  must be determined from Eq. (11.6-
12). If the reflux ratio is set, V1 and L are known. The values H1 and hD can be determined by means of
Eqs. (11.6-1) and (11.6-2) or from an enthalpy–concentration plot. If a value of xn  is selected, it is a trial-
and-error solution to obtain Hn+1, since y n+1 is not known. The steps to follow are given below:

1.  Select a value of xn . Assume Vn+1 = V1 = L + D and Ln  = L. Then using these values in Eq. (11.6-8),


calculate an approximate value for y n+1. This assumes a straight operating line.

2.  Using this y n+1, obtain Hn+1, and obtain hn  using xn . Substitute these values into Eq. (11.6-12)


and solve for Vn+1. Obtain Ln  from Eq. (11.6-6).

3.  Substitute into Eq. (11.6-8) and solve for y n+1.

4.  If the calculated value of y n+1 does not equal the assumed value of y n+1, repeat steps 2–3.


Generally, a second trial is not needed. Assume another value of xn  and repeat steps 1–4.

5.  Plot the curved operating line for the enriching section. Generally, only a few values for the flows
Ln  and Vn+1 are needed to determine the operating line, which is slightly curved.

11.6 C . Distillation in S tr ip p ing S e ction of Tow e r

To analyze the stripping section of a distillation tower, an overall and a component material balance are
made on Fig. 11.4-5a:

Equation 11.6-13
Equation 11.6-14

Equation 11.6-15

Making an enthalpy balance with qR kJ/h or kW(btu/h) entering the reboiler in Fig. 11.4-5a, and
substituting (Vm+1 + W) for Lm from Eq. (11.6-13),

Equation 11.6-16

Making an overall enthalpy balance in Fig. 11.4-3,

Equation 11.6-17

The final working equations to use are Eqs. (11.6-15)–(11.6-17).

Using a method similar to that for the enriching section to solve the equations, select a value of y m+1 and
calculate an approximate value for xm from Eq. (11.6-15), assuming constant molal overflow. Then
calculate Vm+1 and Lm from Eqs. (11.6-16) and (11.6-13). Then use Eq. (11.6-15) to determine xm.
Compare this calculated value of xm with the assumed value.

EXAMPLE 11.6-2. Distillation Using Enthalpy–
Concentration Method
A liquid mixture of benzene–toluene is being distilled under the same conditions as in
Example 11.4-1, except that a reflux ratio of 1.5 times the minimum reflux ratio is to be used.
The value Rm = 1.17 from Example 11.4-2 will be used. Use enthalpy balances to calculate the
flow rates of the liquid and vapor at various points in the tower and plot the curved operating
lines. Determine the number of theoretical stages needed.

S olu t ion: The given data are as follows: F = 100 kg mol/h, xF = 0.45, xD = 0.95, xW = 0.10, R
= 1.5Rm = 1.5(1.17) = 1.755, D = 41.2 kg mol/h, W = 58.8 kg mol/h. The feed enters at 54.4°C
and q = 1.195. The flows at the top of the tower are calculated as follows:
From Fig. 11.1-1, the saturation temperature at the top of the tower for y 1 = xD = 0.95 is
82.3°C. Using Eq. (11.6-2),

This value of 31 206 could also have been obtained from the enthalpy–concentration plot, Fig.
11.6-1. The boiling point of the distillate D is obtained from Fig. 11.1-1 and is 81.1°C. Using Eq.
(11.6-5),

Again, this value could have been obtained from Fig. 11.6-1.

Following the procedure outlined for the enriching section for step 1, a value of xn  = 0.55 is
selected. Assuming a straight operating line for Eq. (11.6-8), an approximate value of y n+1 is
obtained:

Starting with step 2 and using Fig. 11.6-1, for xn  = 0.55, hn  = 1590, and for y n+1 = 0.695, Hn+1


= 33 240. Substituting into Eq. (11.6-12) and solving,

Using Eq. (11.6-6),

For step 3, substituting into Eq. (11.6-8),
This calculated value of y n+1 = 0.700 is sufficiently close to the approximate value of 0.695
that no further trials are needed.

Selecting another value for xn  = 0.70 and using Eq. (11.6-8), an approximate value of y n+1 is


calculated:

Using Fig. 11.6-1 for xn  = 0.70, hn  = 1000, and for y n+1 = 0.791, Hn+1 = 32 500. Substituting


into Eq. (11.6-12) and solving,

Using Eq. (11.6-6),

Substituting into Eq. (11.6-8),

In Fig. 11.6-3, the points for the curved operating line in the enriching section are plotted. This
line is approximately straight and is very slightly above that for constant molal overflow.

Figure 11.6-3. Plot of curved operating lines using enthalpy–concentration method for Example
11.6-2. Solid lines are for enthalpy–concentration method and dashed lines for constant molal
overflow.
Using Eq. (11.6-10), the condenser duty is calculated:

To obtain the reboiler duty qR, values for hW and hF are needed. Using Fig. 11.6-1 for xW =
0.10, hW = 4350. The feed is at 54.5°C. Using Eq. (11.6-5),

Using Eq. (11.6-17),

Using Fig. 11.4-5 and making a material balance below the bottom tray and around the
reboiler,

Equation 11.6-18
Rewriting Eq. (11.6-16) for this bottom section,

Equation 11.6-19

From the equilibrium diagram, Fig. 11.1-2, for xW = 0.10, y W = 0.207, which is the vapor
composition leaving the reboiler.

For equimolal overflow in the stripping section, using Eqs. (11.4-14) and (11.4-15),

Equation 11.4-14

Equation 11.4-15

Selecting y m+1 = y W = 0.207, and using Eq. (11.6-15), an approximate value of xm = xN  is


obtained:

Equation 11.6-15

Solving, xN  = 0.174. From Fig. (11.6-1), for xN  = 0.174, hN  = 3800, and for y W = 0.207, HW =


37 000. Substituting into Eq. (11.6-19),

Solving, VW = 125.0. Using Eq. (11.6-18), LN  = 183.8. Substituting into Eq. (11.6-15) and
solving for xN ,
This value of 0.173 is quite close to the approximate value of 0.174.

Assuming a value of y m+1 = 0.55 and using Eq. (11.6-15), an approximate value of xm is
obtained:

From Fig. (11.6-1), for xm = 0.412, hm = 2300, and for y m+1 = 0.55, Hm = 34 400. Substituting
into Eq. (11.6-16),

Solving, Vm+1 = 126.5. Using Eq. (11.6-13),

Substituting into Eq. (11.6-15) and solving for xm,

This value of 0.407 is sufficiently close to the approximate value of 0.412 that no further trials
are needed. The two points calculated for the stripping section are plotted in Fig. 11.6-3. This
stripping line is also approximately straight and is very slightly above the operating line for
constant molal overflow.

Using the operating line for the enthalpy balance method, the number of theoretical steps is
10.4. Using the equimolal method, 9.9 steps are obtained. This difference would be larger if the
reflux ratio of 1.5 times Rm were decreased to, say, 1.2 or 1.3. At larger reflux ratios, this
difference in number of steps would be less.

Note that in Example 11.6-2, in the stripping section the vapor flow increases slightly from 125.0 to 126.5
in going from the reboiler to near the feed tray. These values are lower than the value of 133.0 obtained
assuming equimolal overflow. Similar conclusions hold for the enriching section. The enthalpy–
concentration method is useful in calculating the internal vapor and liquid flows at any point in the
column. These data are then used in sizing the trays. Also, calculations of qc and qR are used in designing
the condenser and reboiler. This method is very applicable to design using a computer solution for binary
and multicomponent mixtures to make tray-to-tray mass and enthalpy balances for the whole tower. The
more restrictive Ponchon–Savarit graphical method for only binary mixtures is available (K3, T2).
                             
                                                 
                                             
                                               
     

11.7. DISTILLATION OF MULTICOMPONENT MIXTURES

11.7A. Intr od u ction to M u lticom p one nt Distillation

In industry many of the distillation processes involve the separation of more than two components. The
general principles of design for multicomponent distillation towers are the same in many respects as
those described for binary systems. There is one mass balance for each component in the
multicomponent mixture. Enthalpy or heat balances are made which are similar to those for the binary
case. Equilibrium data are used to calculate boiling points and dew points. The concepts of minimum
reflux and total reflux as limiting cases are also used.

1. Nu mb er  of d ist illa t ion t ow er s need ed

In binary distillation, one tower was used to separate the two components A and B into relatively pure
components, with A in the overhead and B in the bottoms. However, in a multicomponent mixture of n
components, n − 1 fractionators will be required for separation. For example, for a three-component
system of components A, B, and C, where A is the most volatile and C the least volatile, two columns will
be needed, as shown in Fig. 11.7-1. The feed of A, B, and C is distilled in column 1, and A and B are
removed in the overhead and C in the bottoms. Since the separation in this column is between B and C,
the bottoms containing C will contain a small amount of B and often a negligible amount of A (often
called trace component). The amount of the trace component A in the bottoms can usually be neglected if
the relative volatilities are reasonably large. In column 2 the feed of A and B is distilled, with A in the
distillate containing a small amount of component B and a much smaller amount of C. The bottoms
containing B will also be contaminated with a small amount of C and A. Alternately, column 1 could be
used to remove A overhead, with B plus C being fed to column 2 for separation of B and C.

Figure 11.7-1. Separation of a ternary system of A, B, and C.

2. Desig n ca lcu la t ion met ho d s

In multicomponent distillation, as in binary, ideal stages or trays are assumed in the stage-to-stage
calculations. Using equilibrium data, equilibrium calculations are used to obtain the boiling point and
equilibrium vapor composition from a given liquid composition or the dew point and liquid composition
from a given vapor composition. Material balances and heat balances similar to those described in
Section 11.6 are then used to calculate the flows to and from the adjacent stages. These stage-to-stage
design calculations involve trial-and-error calculations, and high-speed digital computers are generally
used to provide rigorous solutions.

In a design the conditions of the feed are generally known or specified (temperature, pressure,
composition, flow rate). Then, in most cases, the calculation procedure follows either of two general
methods. In the first method, the desired separation or split between two of the components is specified
and the number of theoretical trays is calculated for a selected reflux ratio. It is clear that with more than
two components in the feed, the complete compositions of the distillate and bottoms are not then known,
and trial-and-error procedures must be used. In the second method, the number of stages in the
enriching section and stripping section and the reflux ratio are specified or assumed and the separation
of the components is calculated using assumed liquid and vapor flows and temperatures for the first
trial. This approach is often preferred for computer calculations (H2, P1). In the trial-and-error
procedures, the design method of Thiele and Geddes (P1, S1, T1), which is reliable, is often used to
calculate resulting distillate and bottoms compositions together with tray temperatures and
compositions. Various combinations and variations of the above rigorous calculation methods are
available in the literature (H2, P1, S1) and will not be considered further.

The variables in the design of a distillation column are all interrelated, and there are only a certain
number of these which may be fixed in the design. For a more detailed discussion of the specification of
these variables, see Kwauk (K2).

3. S hor t cu t  ca lcu la t ion met hod s

In the remainder of this chapter, shortcut calculation methods for the approximate solution of
multicomponent distillation are considered. These methods are quite useful for studying a large number
of cases rapidly to help orient the designer, determine approximate optimum conditions, or provide
information for a cost estimate. Before discussing these methods, equilibrium relationships and
calculation methods of bubble point, dew point, and flash vaporization for multicomponent systems will
be covered.

11.7B. Eq u ilib r iu m  Data in M u lticom p one nt Distillation

For multicomponent systems which can be considered ideal, Raoult's law can be used to determine the
composition of the vapor in equilibrium with the liquid. For example, for a system composed of four
components, A, B, C, and D,

Equation 11.7-1

Equation 11.7-2

In hydrocarbon systems, because of nonidealities, the equilibrium data are often represented by
Equation 11.7-3

where KA is the vapor–liquid equilibrium constant or distribution coefficient for component A. These K
values for light hydrocarbon systems (methane to decane) have been determined semiempirically and
each K is a function of temperature and pressure. Convenient K factor charts are available from
Depriester (D1) and Hadden and Grayson (H1). For light hydrocarbon systems, K is generally assumed
not to be a function of composition, which is sufficiently accurate for most engineering calculations. Note
that for an ideal system, KA = PA/P, and so on. As an example, data for the hydrocarbons n-butane, n-
pentane, n-hexane, and n-heptane are plotted in Fig. 11.7-2 at 405.3 kPa (4.0 atm) absolute (D1, H1).

Figure 11.7-2. Equilibrium K values for light hydrocarbon systems at 405.3 kPa (4.0 atm) absolute.
The relative volatility αi for each individual component in a multicomponent mixture can be defined in a
manner similar to that for a binary mixture. If component C in a mixture, of A, B, C, and D is selected as
the base component,

Equation 11.7-4

The values of Ki will be a stronger function of temperature than the αi values, since the Ki lines in Fig.
11.7-2 all increase with temperature in a similar manner.

11.7C . Boiling Point, De w  Point, and  Flash Distillation

1. Boiling  p oint

At a specified pressure, the boiling point or bubble point of a given multicomponent mixture must satisfy
the relation Σ y i = 1.0. For a mixture of A, B, C, and D, with C as the base component,

Equation 11.7-5

The calculation is a trial-and-error process, as follows. First a temperature is assumed and the values of
αi are calculated from the values of Ki at this temperature. Then the value of KC is calculated from KC =
1.0/∑ αixi. The temperature corresponding to the calculated value of KC = 1.0/∑ αixi. The temperature
corresponding to the calculated value of KC is compared to the assumed temperature. If the values differ,
the calculated temperature is used for the next iteration. After the final temperature is known, the vapor
composition is calculated from

Equation 11.7-6

2. Dew  p oint

For the dew-point calculation, which is also trial and error,

Equation 11.7-7

The value of KC is calculated from KC = 1.0/∑ αixi. After the final temperature is known, the liquid
composition is calculated from
Equation 11.7-8

EXAMPLE 11.7-1. Boiling Point of a Multicomponent
Liquid
A liquid feed to a distillation tower at 405.3 kPa abs is fed to a distillation tower. The
composition in mole fractions is as follows: n-butane (xA = 0.40), n-pentane (xB = 0.25), n-
hexane (xC = 0.20), n-heptane (xD = 0.15). Calculate the boiling point and the vapor in
equilibrium with the liquid.

S olu t ion: First a temperature of 65°C is assumed and the values of K obtained from Fig. 11.7-
2. Using component C (n-hexane) as the base component, the following values are calculated
using Eq. (11.7-5) for the first trial:

Trial 1 (65°C) Trial 3 (70°C) Final

Comp. xi Ki αi x i Ki αi αi x i yi

A 0.40 1.68 6.857 2.743 1.86 6.607 2.643 0.748

B 0.25 0.63 2.571 0.643 0.710 2.522 0.631 0.178

C 0.20 0.245 1.000 0.200 0.2815 1.000 0.200 0.057


D 0.15 0.093 0.380 0.057 0.110 0.391 0.059 0.017

  1.00   ∑ αixi = 3.643   ∑ αixi = 3.533 1.000

KC = 1/∑ αixi = 1/3.643 = 0.2745(69°C) KC = 1/3.533 = 0.2830 (70°C)

The calculated value of KC is 0.2745, which corresponds to 69°C, Fig. 11.7-2. Using 69°C for
trial 2, a temperature of 70°C is obtained. Using 70°C for trial 3, the calculations shown give a
final calculated value of 70°C, which is the bubble point. Values of y i are calculated from Eq.
(11.7-6).

3. Fla sh d ist illa t ion of mu lt icomp onent  mixt u r e

For flash distillation, the process flow diagram is shown in Fig. 11.3-1. Defining f = V/F as the fraction of
the feed vaporized and (1 − f) = L/F as the fraction of the feed remaining as liquid, and making a
component i balance as in Eq. (11.3-6), the following is obtained:

Equation 11.7-9

where y i is the composition of i in the vapor, in equilibrium with xi in the liquid after vaporization. For
equilibrium, y i = Kixi = KCαixi, where αi = Ki/KC. Then Eq. (11.7-9) becomes

Equation 11.7-10

Solving for xi and summing for all components,

Equation 11.7-11

This is solved by trial and error by first assuming a temperature if the fraction f vaporized has been set.
When the ∑ xi values add up to 1.0, the proper temperature has been chosen. The composition of the
vapor y i can be obtained from y i = KCαixi or by a material balance.

11.7D. K e y C om p one nts in M u lticom p one nt Distillation

Fractionation of a multicomponent mixture in a distillation tower will allow separation only between two
components. For a mixture of A, B, C, D, and so on, a separation in one tower can only be made between
A and B, or B and C, and so on. The components separated are called the light key, which is the more
volatile (identified by the subscript L), and the heavy key (H). The components more volatile than the
light key are called light components and will be present in the bottoms in small amounts. The
components less volatile than the heavy key are called heavy components and will be present in the
distillate in small amounts. The two key components are present in significant amounts in both the
distillate and bottoms.

11.7E. Total R e flu x for  M u lticom p one nt Distillation

1. M inimu m st a g es for  t ot a l r eflu x

Just as in binary distillation, the minimum number of theoretical stages or steps, Nm, can be determined
for multicomponent distillation for total reflux. The Fenske equation (11.4-23) also applies to any two
components in a multicomponent system. When applied to the heavy key H and the light key L, it
becomes

Equation 11.7-12

where xLD is mole fraction of light key in distillate, xLW is mole fraction in bottoms, xHD is mole fraction
of heavy key in distillate, and xHW is mole fraction in bottoms. The average value of αL of the light key is
calculated from αLD at the top temperature (dew point) of the tower and αLW at the bottoms
temperature:

Equation 11.7-13

Note that the distillate dew-point and bottoms boiling-point estimation is partially trial and error, since
the distribution of the other components in the distillate and bottoms is not known and can affect these
values.

2. Dist r ib u t ion of ot her  comp onent s

To determine the distribution or concentration of other components in the distillate and bottoms at total
reflux, Eq. (11.7-12) can be rearranged and written for any other component i as follows:

Equation 11.7-14

These concentrations of the other components determined at total reflux can be used as approximations
with finite and minimum reflux ratios. More accurate methods for finite and minimum reflux are
available elsewhere (H2, S1, V1).

EXAMPLE 11.7-2. Calculation of Top and Bottom
Temperatures and Total Reflux
The liquid feed of 100 mol/h at the boiling point given in Example 11.7-1 is fed to a distillation
tower at 405.3 kPa and is to be fractionated so that 90% of the n-pentane (B) is recovered in
the distillate and 90% of the n-hexane (C) in the bottoms. Calculate the following:

a.  Moles per hour and composition of distillate and bottoms.

b.  Top temperature (dew point) of distillate and boiling point of bottoms.

c.  Minimum stages for total reflux and distribution of other components in the distillate
and bottoms.

S olu t ion: For part (a), material balances are made for each component, with component n-
pentane (B) being the light key (L) and n-hexane (C) the heavy key (H). For the overall
balance,

Equation 11.7-15

For component B, the light key,

Equation 11.7-16
Since 90% of B is in the distillate, y BDD = (0.90)(25) = 22.5. Hence, xBWW = 2.5. For
component C, the heavy key,

Equation 11.7-17

Also, 90% of C is in the bottoms, and xCWW = 0.90(20) = 18.0. Then, y CDD = 2.0. For the first
trial, it is assumed that no component D (heavier than the heavy key C) is in the distillate and
no light A in the bottoms. Hence, moles A in distillate = y ADD = 0.40(100) = 40.0. Also, moles
D in bottoms = xDWW = 0.15(100) = 15.0. These values are tabulated below.

  Feed. F Distillate, D Bottoms, W

Comp. xF x FF y D =x D y DD x W x WW

A 0.40 40.0 0.620 40.0 0 0

B (lt key L) 0.25 25.0 0.349 22.5 0.070 2.5

C (hy key H) 0.20 20.0 0.031 2.0 0.507 18.0


D 0.15 15.0 0 0 0.423 rowsep="1"15.0

  1.00 F = 100.0 1.000 D = 64.5 1.000 W = 35.5

For the dew point of the distillate (top temperature) in part (b), a value of 67°C will be
estimated for the first trial. The K values are read from Fig. 11.7-2 and the α values calculated.
Using Eqs. (11.7-7) and (11.7-8), the following values are calculated:

Comp. y iD K i (67°C) αi y i /αi xi

A 0.620 1.75 6.73 0.0921 0.351

B (L) 0.349 0.65 2.50 0.1396 0.531


C (H) 0.031 0.26 1.00 0.0310 0.118
D 0 0.10 0.385 0 0

  1.000     ∑ yi/αi = 0.2627 1.000

  KC = ∑ yi/αi= 0.2627

The calculated value of KC is 0.2627, which corresponds very closely to 67°C, which is the final
temperature of the dew point.

For the bubble point of the bottoms, a temperature of 135°C is assumed for trial 1 and Eqs.
(11.7-5) and (11.7-6) used for the calculations. A second trial using 132°C gives the final
temperature as shown below:

Comp. x iW Ki αi αi x i yi
A 0 5.00 4.348 0 0
B (L) 0.070 2.35 2.043 0.1430 0.164
C (H) 0.507 1.15 1.000 0.5070 0.580
D 0.423 0.61 0.530 0.2242 0.256

  1.000   ∑ αixi = 0.8742 1.000

  KC = 1/0.8742 = 1.144

The calculated value of KC is 1.144, which is close to the value at 132°C.

For part (c) the proper α values of the light key L (n-pentane) to use in Eq. (11.7-13) are as
follows:

Equation 11.7-13

Substituting into Eq. (11.7-12),

The distribution or compositions of the other components can be calculated using Eq. (11.7-
14). For component A, the average α value to use is

Equation 11.7-14

Making an overall balance on A,

Equation 11.7-18

Substituting xADD = 1017xAWW from Eq. (11.7-14) into (11.7-18) and solving,
For the distribution of component D, αD,av  =   = 0.452.

Solving, xDDD = 0.023, xDWW = 14.977.

The revised distillate and bottoms compositions are as follows:

  Distillate, D Bottoms, W

Comp. y D =x D x DD xW x WW

A 0.6197 39.961 0.0011 0.039

B (L) 0.3489 22.500 0.0704 2.500

C (H) 0.0310 2.000 0.5068 18.000


D 0.0004 0.023 0.4217 14.977

  1.0000 D = 64.484 1.0000 W = 35.516

Hence, the number of moles of D in the distillate is quite small, as is the number of moles of A
in the bottoms.

Using the new distillate composition, a recalculation of the dew point assuming 67°C gives a
calculated value of KC = 0.2637. This is very close to that of 0.2627 obtained when the trace
amount of D in the distillate was assumed as zero. Hence, the dew point is 67°C. Repeating
the bubble-point calculation for the bottoms assuming 132°C, a calculated value of KC = 1.138,
which is close to the value at 132°C. Hence, the bubble point remains at 132°C. If either the
bubble- or dew-point temperatures had changed, the new values would then be used in a
recalculation of Nm.

11.7F. S hor tcu t M e thod  for  M inim u m  R e flu x R atio for  M u lticom p one nt Distillation

As in the case of binary distillation, the minimum reflux ratio Rm is that reflux ratio which will require an
infinite number of trays for the given separation of the key components.

For binary distillation, only one “pinch point” occurs where the number of steps becomes infinite, and
that is usually at the feed tray. For multicomponent distillation, two pinch points or zones of constant
composition occur: one in the section above the feed plate and another below the feed tray. The rigorous
plate-by-plate stepwise procedure for calculating Rm is trial and error and can be extremely tedious for
hand calculations.
Underwood's shortcut method for calculating Rm (U1, U2) uses constant average α values and assumes
constant flows in both sections of the tower. This method provides a reasonably accurate value. The two
equations to be solved in order to determine the minimum reflux ratio are

Equation 11.7-19

Equation 11.7-20

The values of xiD for each component in the distillate in Eq. (11.7-20) are supposed to be the values at the
minimum reflex. However, as an approximation, the values obtained using the Fenski total reflux
equation are used. Since each αi may vary with temperature, the average value of αi to use in the
preceding equations is approximated by using αi at the average temperature of the top and bottom of the
tower. Some (P1, S1) have used the average α which is used in the Fenske equation or the α at the entering
feed temperature. To solve for Rm, the value of θ in Eq. (11.7-19) is first obtained by trial and error. This
value of θ lies between the α value of the light key and the α value of the heavy key, which is 1.0. Using
this value of θ in Eq. (11.7-20), the value of Rm is obtained directly. When distributed components
appear between the key components, modified methods described by others (S1, T2, V1) can be used.

11.7G . S hor tcu t M e thod  for  Nu m b e r  of S tage s at Op e r ating R e flu x R atio

1. Nu mb er  of st a g es a t  op er a t ing  r eflu x r a t io

The determination of the minimum number of stages for total reflux presented in Section 11.7E and the
minimum reflux ratio presented in Section 11.7F are useful for setting the allowable ranges for number of
stages and flow conditions. These ranges are helpful in selecting the particular operating conditions for a
design calculation. The relatively complex rigorous procedures for doing a stage-by-stage calculation at
any operating reflux ratio have been discussed in Section 11.7A.

An important shortcut method for determining the theoretical number of stages required for an operating
reflux ratio R is the empirical correlation of Erbar and Maddox (E1) given in Fig. 11.7-3. This correlation
is somewhat similar to a correlation by Gilliland (G1) and should be considered as an approximate
method. In Fig. 11.7-3 the operating reflux ratio R (for flow rates at the column top) is correlated with the
minimum Rm obtained using the Underwood method, the minimum number of stages Nm obtained by
the Fenske method, and the number of stages N at the operating R.

Figure 11.7-3. Erbar–Maddox correlation between reflux ratio and number of stages (Rm  based on

Underwood method). [From J. H. Erbar and R. N. Maddox, Petrol. Refiner, 40(5), 183 (1961). With permission.]
2. Est ima t e of feed -p la t e loca t ion

Kirkbride (K1) has devised an approximate method to estimate the number of theoretical stages above
and below the feed which can be used to estimate the feed-stage location. This empirical relation is as
follows:

Equation 11.7-21

where Ne is the number of theoretical stages above the feed plate and Ns the number of theoretical stages
below the feed plate.

EXAMPLE 11.7-3. Minimum Reflux Ratio and Number of
Stages at Operating Reflux Ratio
Using the conditions and results given in Example 11.7-2, calculate the following:

a.  Minimum reflux ratio using the Underwood method.

b.  Number of theoretical stages at an operating reflux ratio R of 1.5Rm using the Erbar–
Maddox correlation.

c.  Location of feed tray using the method of Kirkbride.
S olu t ion: For part (a), the temperature to use for determining the values of αi is the average
between the top of 67°C and the bottom of 132°C (from Example 11.7-2) and is (67 + 132)/2, or
99.5°C. The Ki values obtained from Fig. 11.7-2 and the αi values and distillate and feed
compositions to use in Eqs. (11.7-19) and (11.7-20) are as follows:

Comp. x iF x iD K i  (99.5°C) αi  (99.5°C) x iW

A 0.40 0.6197 3.12 5.20 0.0011


B (L) 0.25 0.3489 1.38 2.30 0.0704
C (H) 0.20 0.0310 0.60 1.00 0.5068

D 0.15 0.0004 0.28 0.467 0.4217

  1.00 1.0000     1.0000

Substituting into Eq. (11.7-19) with q = 1.0 for feed at the boiling point,

Equation 11.7-22

This is trial and error, so a value of θ = 1.210 will be used for the first trial (θ must be between
2.30 and 1.00). This and other trials are shown below:

  2.08 0.575 0.200 0.070  

θ (Assumed) 5.2 − θ 2.3 − θ 1.0 − θ 0.467 − θ ∑ (Sum)

1.210 0.5213 0.5275 −0.9524 −0.0942 +0.0022

1.200 0.5200 0.5227 −1.0000 −0.0955 −0.0528

1.2096 0.5213 0.5273 −0.9542 −0.0943 +0.0001

The final value of θ = 1.2096 is substituted into Eq. (11.7-20) to solve for Rm:

Solving, Rm = 0.395.

For part (b), the following values are calculated: R = 1.5Rm = 1.5(0.395) = 0.593, R/(R + 1) =
0.593/(0.593 + 1.0) = 0.3723, Rm/(Rm + 1) = 0.395/(0.395 + 1.0) = 0.2832. From Fig. 11.7-3,
Nm/N = 0.49. Hence, Nm/N = 0.49 = 5.40/N. Solving, N = 11.0 theoretical stages in the tower.
This gives 11.0 − 1.0 (reboiler), or 10.0 theoretical trays.

For the location of the feed tray in part (c), using Eq. (11.7-21),
Hence, Ne/Ns = 1.184. Also, Ne + Ns = 1.184Ns + Ns = N = 11.0 stages.

Solving, Ns = 5.0 and Ne = 6.0. This means that the feed tray is 6.0 trays from the top.
                             
                                                 
                                             
                                               
     

PROBLEMS
11.1-1.
Pha se R u le for  a  Va p or  S y st em. For the system NH3–water and only a vapor phase present,
calculate the number of degrees of freedom. What variables can be fixed?
A1:Ans. F = 3 degrees of freedom; variables T, P, y A
11.1-2.
Boiling  Point  a nd  R a ou lt 's La w . For the system benzene–toluene, do as follows, using the
data from Table 11.1-1:

a.  At 378.2 K, calculate y A and xA using Raoult's law.

b.  If a mixture has a composition of xA = 0.40 and is at 358.2 K and 101.32 kPa pressure,
will it boil? If not, at what temperature will it boil and what will be the composition of the
vapor first coming off?

11.1-3.
Boiling -Point -Dia g r a m C a lcu la t ion. The vapor-pressure data are given below for the
system hexane–octane:

    Vapor Pressure

    n-Hexane n-Octane

T(°F) T(°C) kPa mm Hg kPa mm Hg

155.7 68.7 101.3 760 16.1 121

175 79.4 136.7 1025 23.1 173

200 93.3 197.3 1480 37.1 278


225 107.2 284.0 2130 57.9 434

258.2 125.7 456.0 3420 101.3 760

a.  Using Raoult's law, calculate and plot the x-y data at a total pressure of 101.32 kPa.

b.  Plot the boiling-point diagram.

11.2-1.
S ing le-S t a g e C ont a ct  of Va p or –Liq u id  S y st em. A mixture of 100 mol containing 60 mol
% n-pentane and 40 mol % n-heptane is vaporized at 101.32 kPa abs pressure until 40 mol of
vapor and 60 mol of liquid in equilibrium with each other are produced. This occurs in a single-
stage system, and the vapor and liquid are kept in contact with each other until vaporization is
complete. The equilibrium data are given in Example 11.3-2. Calculate the composition of the
vapor and the liquid.

11.3-1.
R ela t iv e Vola t ilit y  of a  Bina r y  S y st em. Using the equilibrium data for the n-pentane–n-
heptane system given in Example 11.3-2, calculate the relative volatility for each concentration
and plot α versus the liquid composition xA.
11.3-2.
C omp a r ison of Differ ent ia l a nd  Fla sh Dist illa t ion. A mixture of 100 kg mol which
contains 60 mol % n-pentane (A) and 40 mol % n-heptane (B) is vaporized at 101.32 kPa
pressure under differential conditions until 40 kg mol are distilled. Use equilibrium data from
Example 11.3-2.

a.  What is the average composition of the total vapor distilled and the composition of the
remaining liquid?

b.  If this same vaporization is done in an equilibrium or flash distillation and 40 kg mol are
distilled, what is the composition of the vapor distilled and of the remaining liquid?

A6 :Ans. (a) x2 = 0.405, y av  = 0.892; (b) x2 = 0.430, y 2 = 0.854


11.3-3.
Differ ent ia l Dist illa t ion of Benzene–Tolu ene. A mixture containing 70 mol % benzene
and 30 mol % toluene is distilled under differential conditions at 101.32 kPa (1 atm). A total of
one-third of the moles in the feed is vaporized. Calculate the average composition of the
distillate and the composition of the remaining liquid. Use equilibrium data from Table 11.1-1.
11.3-4 .
S t ea m Dist illa t ion of Et hy la niline. A mixture contains 100 kg of H2O and 100 kg of
ethylaniline (mol wt = 121.1 kg/kg mol), which is immiscible with water. A very slight amount of
nonvolatile impurity is dissolved in the organic. To purify the ethylaniline, it is steam-distilled
by bubbling saturated steam into the mixture at a total pressure of 101.32 kPa (1 atm).
Determine the boiling point of the mixture and the composition of the vapor. The vapor pressure
of each of the pure compounds is as follows (T1):

Temperature    

K °C PA (water) (kPa) PB (ethylaniline) (kPa)

353.8 80.6 48.5 1.33


369.2 96.0 87.7 2.67

372.3 99.15 98.3 3.04

386.4 113.2 163.3 5.33

11.3-5.
S t ea m Dist illa t ion of Benzene. A mixture of 50 g mol of liquid benzene and 50 g mol of water
is boiling at 101.32 kPa pressure. Liquid benzene is immiscible in water. Determine the boiling
point of the mixture and the composition of the vapor. Which component will first be removed
completely from the still? Vapor-pressure data for the pure components are as follows:

Temperature    

K °C Pwater  (mm Hg) Pbenzene  (mm Hg)

308.5 35.3 43 150

325.9 52.7 106 300


345.8 72.6 261 600

353.3 80.1 356 760


11.4 -1.
Dist illa t ion Using  M cC a b e–Thiele M et hod . A rectification column is fed 100 kg mol/h of a
mixture of 50 mol % benzene and 50 mol % toluene at 101.32 kPa abs pressure. The feed is liquid
at the boiling point. The distillate is to contain 90 mol % benzene and the bottoms 10 mol %
benzene. The reflux ratio is 4.52:1. Calculate the kg mol/h distillate, kg mol/h bottoms, and the
number of theoretical trays needed using the McCabe–Thiele method.
A10:Ans. D = 50 kg mol/h, W = 50 kg mol/h, 4.9 theoretical trays plus reboiler
11.4 -2.
R ect ifica t ion of a  Hep t a ne–Et hy l Benzene M ixt u r e. A saturated liquid feed of 200 mol/h
at the boiling point containing 42 mol % heptane and 58% ethyl benzene is to be fractionated at
101.32 kPa abs to give a distillate containing 97 mol % heptane and a bottoms containing 1.1
mol % heptane. The reflux ratio used is 2.5:1. Calculate the mol/h distillate, mol/h bottoms,
theoretical number of trays, and the feed tray number. Equilibrium data are given below at
101.32 kPa abs pressure for the mole fraction n-heptane xH and y H:

Temperature     Temperature    

K °C xH yH K °C xH yH

409.3 136.1 0 0 383.8 110.6 0.485 0.730


402.6 129.4 0.08 0.230 376.0 102.8 0.790 0.904

392.6 119.4 0.250 0.514 371.5 98.3 1.000 1.000

A11:Ans. D = 85.3 mol/h, W = 114.7 mol/h, 9.5 trays + reboiler, feed on tray 6 from top
11.4 -3.
G r a p hica l S olu t ion for  M inimu m R eflu x R a t io a nd  Tot a l R eflu x. For the rectification
given in Problem 11.4-1, where an equimolar liquid feed of benzene and toluene is being distilled
to give a distillate of composition xD = 0.90 and a bottoms of composition xW = 0.10, calculate
the following using graphical methods:

a.  Minimum reflux ratio Rm.

b.  Minimum number of theoretical plates at total reflux.

A12:Ans. (a) Rm = 0.91; (b) 4.0 theoretical trays plus a reboiler
11.4 -4 .
M inimu m Nu mb er  of Theor et ica l Pla t es a nd  M inimu m R eflu x R a t io. Determine the
minimum reflux ratio Rm and the minimum number of theoretical plates at total reflux for the
rectification of a mixture of heptane and ethyl benzene as given in Problem 11.4-2. Do this by
using the graphical methods of McCabe–Thiele.
11.4 -5.
R ect ifica t ion Using  a  Pa r t ia lly  Va p or ized  Feed . A total feed of 200 mol/h having an
overall composition of 42 mol % heptane and 58 mol % ethyl benzene is to be fractionated at
101.3 kPa pressure to give a distillate containing 97 mol % heptane and a bottoms containing 1.1
mol % heptane. The feed enters the tower partially vaporized so that 40 mol % is liquid and 60
mol % vapor. Equilibrium data are given in Problem 11.4-2. Calculate the following:

a.  Moles per hour distillate and bottoms.

b.  Minimum reflux ratio Rm.
c.  Minimum steps and theoretical trays at total reflux.

d.  Theoretical number of trays required for an operating reflux ratio of 2.5:1. Compare with
the results of Problem 11.4-2, which uses a saturated liquid feed.

11.4 -6 .
Dist illa t ion Using  a  Va p or  Feed . Repeat Problem 11.4-1 but use a feed that is saturated
vapor at the dew point. Calculate the following:

a.  Minimum reflux ratio Rm.

b.  Minimum number of theoretical plates at total reflux.

c.  Theoretical number of trays at an operating reflux ratio of 1.5(Rm).

11.4 -7.
Enr iching  Tow er  for  Benzene–Tolu ene. An enriching tower is fed 100 kg mol/h of a
saturated vapor feed containing 40 mol % benzene (A) and 60 mol % toluene (B) at 101.32 kPa
abs. The distillate is to contain 90 mol % benzene. The reflux ratio is set at 4.0:1. Calculate the
kg mol/h distillate D and bottoms W and their compositions. Also, calculate the number of
theoretical plates required.
A16 :Ans. D = 20 kg mol/h, W = 80 kg mol/h, xW = 0.275
11.4 -8.
S t r ip p ing  Tow er . A liquid mixture containing 10 mol % n-heptane and 90 mol % n-octane is
fed at its boiling point to the top of a stripping tower at 101.32 kPa abs. The bottoms are to
contain 98 mol % n-octane. For every 3 mol of feed, 2 mol of vapor is withdrawn as product.
Calculate the composition of the vapor and the number of theoretical plates required. The
equilibrium data below are given as mole fraction n-heptane.

x y x y

0.284 0.459 0.039 0.078

0.097 0.184 0.012 0.025


0.067 0.131    

11.4 -9 .
S t r ip p ing  Tow er  a nd  Dir ect  S t ea m Inject ion. A liquid feed at the boiling point contains
3.3 mol % ethanol and 96.7 mol % water and enters the top tray of a stripping tower. Saturated
steam is injected directly into liquid in the bottom of the tower. The overhead vapor which is
withdrawn contains 99% of the alcohol in the feed. Assume equimolar overflow for this problem.
Equilibrium data for mole fraction of alcohol are as follows at 101.32 kPa abs pressure (1 atm
abs):

x y x y

0 0 0.0296 0.250
0.0080 0.0750 0.033 0.270
0.020 0.175    
a.  For an infinite number of theoretical steps, calculate the minimum moles of steam needed
per mole of feed. (Note: Be sure to plot the q line.)

b.  Using twice the minimum moles of steam, calculate the number of theoretical steps
needed, the composition of the overhead vapor, and the bottoms composition.

A18:Ans. (a) 0.121 mol steam/mol feed; (b) 5.0 theoretical steps, xD = 0.135, xW = 0.00033
11.5-1.
M u r p hr ee Efficiency  a nd  Act u a l Nu mb er  of Tr a y s. For the distillation of heptane and
ethyl benzene in Problem 11.4-2, the Murphree tray efficiency is estimated as 0.55. Determine the
actual number of trays needed by stepping off the trays using the tray efficiency of 0.55. Also,
calculate the overall tray efficiency EO.
11.5-2.
Pa ck ing  a nd  Tr a y  Efficiencies for  Ab sor p t ion Tow er . An absorber in a petroleum
refinery uses a lean oil to absorb butane from a natural gas stream. The composition of the key
component butane in the gas phase is related to its composition in the liquid phase at
equilibrium by y = mx = 0.7x. At the tower bottom, where the flows are largest, ρL = 57.9 lbm/ft 3

(927 kg/m3). At the average tower temperature, μL = 1.4 cp and the average molecular weight of
the liquid is ML = 245. Estimate the efficiency for a valve-tray tower and the HETP for Norton
Intalox 2T structured packing.

11.5-3.
Est ima t ion of Tow er  Dia met er  of S iev e Tr a y . A distillation sieve-tray tower is being used
to distill a hydrocarbon feed. The vapor flow rate at the tower bottom is 21 000 kg/hr and the
liquid flow rate is 19 500 kg/hr. The density of the liquid ρL = 673 kg/m3 and ρV = 3.68 kg/m3.
Assume a tray spacing of 24 in. (0.610 m). Calculate the tower diameter assuming the tower
operates at 80% of flooding. Assume σ = 22.5 dyn/cm.
A21:Ans. Kv  = 0.35, D = 1.372 m (4.50 ft)
11.6 -1.
Use of Ent ha lp y –C oncent r a t ion M et hod  t o Dist ill a n Et ha nol–W a t er  S olu t ion. A
mixture of 50 wt % ethanol and 50 wt % water which is saturated liquid at the boiling point is to
be distilled at 101.3 kPa pressure to give a distillate containing 85 wt % ethanol and a bottoms
containing 3 wt % ethanol. The feed rate is 453.6 kg/h and a reflux ratio of 1.5 is to be used. Use
equilibrium and enthalpy data from Appendix A.3. Note that the data are given in wt fraction
and kJ/kg. Use these consistent units in plotting the enthalpy–concentration data and
equilibrium data. Do as follows:

a.  Calculate the amount of distillate and bottoms.

b.  Calculate the number of theoretical trays needed.

c.  Calculate the condenser and reboiler loads.

A22:Ans. (a) D = 260.0 kg/h, W = 193.6 kg/h (b) 3.9 trays plus a reboiler (c) qc = 698 750 kJ/h, qR =
704 770 kJ/h
11.6 -2.
Dist illa t ion of Et ha nol–W a t er  S olu t ion Using  Ent ha lp y –C oncent r a t ion M et hod .
Repeat Problem 11.6-1 but use a reflux ratio of 2.0 instead of 1.5.
A23:Ans. 3.6 theoretical trays plus reboiler
11.6 -3.
M inimu m R eflu x a nd  Theor et ica l Nu mb er  of Tr a y s. A feed of ethanol–water containing
60 wt % ethanol is to be distilled at 101.32 kPa pressure to give a distillate containing 85 wt %
ethanol and a bottoms containing 2 wt % ethanol. The feed rate is 10 000 kg/h and its enthalpy
is 116.3 kJ/kg (50 btu/lbm). Use consistent units of kg/h, weight fraction, and kJ/kg.

a.  Calculate the amount of distillate and bottoms.

b.  Determine the minimum reflux ratio using enthalpy–concentration data from Appendix
A.3.

c.  Using 2.0 times the minimum reflux ratio, determine the theoretical number of trays
needed.

d.  Calculate the condenser and reboiler heat loads.

e.  Determine the minimum number of theoretical plates at total reflux.

A24 :Ans. (b) Rm = 0.373 (c) 4.4 theoretical trays plus reboiler (d) qc = 3634 kW, qR = 4096 kW (e)
2.8 theoretical trays plus reboiler
11.6 -4 .
Dist illa t ion of Benzene–Tolu ene Feed  Using  Ent ha lp y –C oncent r a t ion M et hod . A
liquid feed of 100 kg mol/h of benzene–toluene at the boiling point contains 55 mol % benzene
and 45 mol % toluene. It is being distilled at 101.32 kPa pressure to give a distillate with xD =
0.98 and a bottoms of xW = 0.04. Using a reflux ratio of 1.3 times the minimum and the
enthalpy-concentration method, do as follows:

a.  Determine the theoretical number of trays needed.

b.  Calculate the condenser and reboiler heat loads.

c.  Determine the minimum number of theoretical trays at total reflux.

11.6 -5.
Use of Ent ha lp y –C oncent r a t ion Plot . For the system benzene–toluene do as follows:

a.  Plot the enthalpy–concentration data using values from Table 11.6-2. For a value of x =
0.60 = y, calculate the saturated liquid enthalpy h and the saturated vapor enthalpy H
and plot these data on the graph.

b.  A mixture contains 60 mol of benzene and 40 mol of toluene. This mixture is heated so
that 30 mol of vapor are produced. The mixture is in equilibrium. Determine the enthalpy
of this overall mixture and plot this point on the enthalpy–concentration diagram.

11.7-1.
Fla sh Va p or iza t ion of M u lt icomp onent  Feed . For the feed to the distillation tower of
Example 11.7-1, calculate the following:

a.  Dew point of feed and composition of liquid in equilibrium. (Note: The boiling point of
70°C has already been calculated.)

b.  The temperature and composition of both phases when 40% of the feed is vaporized in a
flash distillation.

A27:Ans. (a) 107°C, xA = 0.114, xB = 0.158, xC = 0.281, xD = 0.447; (b) 82°C, xA = 0.260, xB = 0.254,
xC = 0.262, xD = 0.224; y A = 0.610, y B = 0.244, y C = 0.107, y D = 0.039
11.7-2.
Boiling  Point , Dew  Point , a nd  Fla sh Va p or iza t ion. Following is the composition of a
liquid feed in mole fraction: n-butane (xA = 0.35), n-pentane (xB = 0.20), n-hexane (xC = 0.25),
n-heptane (xD = 0.20). At a pressure of 405.3 kPa calculate the following.

a.  Boiling point and composition of the vapor in equilibrium.

b.  Dew point and composition of the liquid in equilibrium.

c.  The temperature and composition of both phases when 60% of the feed is vaporized in a
flash distillation.

11.7-3.
Va p or iza t ion of M u lt icomp onent  Alcohol M ixt u r e. The vapor-pressure data are given
below for the following alcohols:

  Vapor Pressure (mm Hg)

T(°C) Methanol Ethanol n-Propanol n-Butanol

50 415 220.0 88.9 33.7

60 629 351.5 148.9 59.2

65 767 438 190.1 77.7

70 929 542 240.6 99.6


75 1119 665 301.9 131.3

80 1339 812 376.0 165.0

85 1593 984 465 206.1


90 1884 1185 571 225.9

100 2598 1706 843 387.6

Following is the composition of a liquid alcohol mixture to be fed to a distillation tower at 101.32
kPa: methyl alcohol (xA = 0.30), ethyl alcohol (xB = 0.20) n-propyl alcohol (xC = 0.15), and n-
butyl alcohol (xD = 0.35). Calculate the following assuming that the mixture follows Raoult's
law:

a.  Boiling point and composition of vapor in equilibrium.

b.  Dew point and composition of liquid in equilibrium.

c.  The temperature and composition of both phases when 40% of the feed is vaporized in a
flash distillation.

A29 :Ans. (a) 83°C, y A = 0.589, y B = 0.241, y C = 0.084, y D = 0.086; (b) 100°C, xA = 0.088, xB =


0.089, xC = 0.136, xD = 0.687
11.7-4 .
Tot a l R eflu x, M inimu m R eflu x, Nu mb er  of S t a g es. The following feed of 100 mol/h at the
boiling point and 405.3 kPa pressure is fed to a fractionating tower: n-butane (xA = 0.40), n-
pentane (xB = 0.25), n-hexane (xC = 0.20), n-heptane (xD = 0.15). This feed is distilled so that
95% of the n-pentane is recovered in the distillate and 95% of the n-hexane in the bottoms.
Calculate the following:

a.  Moles per hour and composition of distillate and bottoms.

b.  Top and bottom temperature of tower.

c.  Minimum stages for total reflux and distribution of other components (trace components)
in the distillate and bottoms, that is, moles and mole fractions. [Also correct the
compositions and moles in part (a) for the traces.]

d.  Minimum reflux ratio using the Underwood method.

e.  Number of theoretical stages at an operating reflux ratio of 1.3 times the minimum using
the Erbar–Maddox correlation.

f.  Location of the feed tray using the Kirkbride method.

A30:Ans. (a) D = 64.75 mol/h, xAD = 0.6178, xBD = 0.3668, xCD = 0.0154, xDD = 0; W = 35.25
mol/h, xAW = 0, xBW = 0.0355, xCW = 0.5390, xDW = 0.4255; (b) top, 66°C; bottom, 134°C; (c)

Nm = 7.14 stages; trace compositions, xAW = 1.2 × 10−4, xDD = 4.0 × 10−5; (d) Rm = 0.504; (e) N
= 16.8 stages; (f) Ne = 9.1 stages, Ns = 7.7 stages, feed 9.1 stages from top
11.7-5.
S hor t cu t  Desig n of M u lt icomp onent  Dist illa t ion Tow er . A feed of part liquid and part
vapor (q = 0.30) at 405.4 kPa is fed at the rate of 1000 mol/h to a distillation tower. The overall
composition of the feed is n-butane (xA = 0.35), n-pentane (xB = 0.30), n-hexane (xC = 0.20),
and n-heptane (xD = 0.15). The feed is distilled so that 97% of the n-pentane is recovered in the
distillate and 85% of the n-hexane in the bottoms. Calculate the following:

a.  Amount and composition of products and top and bottom tower temperatures.

b.  Number of stages at total reflux and distribution of other components in the products.

c.  Minimum reflux ratio, number of stages at 1.2Rm, and feed-tray location.

11.7-6 .
Dist illa t ion of M u lt icomp onent  Alcohol M ixt u r e. A feed of 30 mol % methanol (A), 20%
ethanol (B), 15% n-propanol (C), and 35% n-butanol (D) is distilled at 101.32 kPa abs pressure
to give a distillate composition containing 95.0 mol % methanol and a residue composition
containing 5.0% methanol and the other components as calculated. The feed is below the boiling
point, so that q = 1.1. The operating reflux ratio is 3.0. Assume that Raoult's law applies and use
vapor-pressure data from Problem 11.7-3. Calculate the following:

a.  Composition and amounts of distillate and bottoms for a feed of 100 mol/h.

b.  Top and bottom temperatures and number of stages at total reflux. (Also, calculate the
distribution of the other components.)

c.  Minimum reflux ratio, number of stages at R = 3.00, and feed-tray location.

A32:Ans. (a) D = 27.778 mol/h, xAD = 0.95, xBD = 0.05, xCD = 0, xDD = 0; W = 72.222 mol/h, xAW =
0.0500, xBW = 0.2577, xCW = 0.2077, xDW = 0.4846; (b) 65.5°C top temperature, 94.3°C
bottom, N  = 9.21 stages, x  = 3.04 × 10−5, x  = 8.79 × 10−7  (trace compositions); (c) R  =
m CD DD m
2.20, N = 16.2 stages, Ns = 7.6, Ne = 8.6, feed on stage 8.6 from top
11.7-7.
S hor t cu t  Desig n M et hod  for  Dist illa t ion of Ter na r y  M ixt u r e. A liquid feed at its bubble
point is to be distilled in a tray tower to produce the distillate and bottoms as follows: Feed, xAF
= 0.047, xBF = 0.072, xCF = 0.881; distillate, xAD = 0.1260, xBD = 0.1913, xCD = 0.6827;
bottoms, xAW = 0, xBW = 0.001, xCW = 0.999. Average α values to use are αA = 4.19, αB = 1.58,
αC = 1.00.

a.  For a feed rate of 100 mol/h, calculate D and W, number of stages at total reflux, and
distribution (concentration) of A in the bottoms.

b.  Calculate Rm and the number of stages at 1.25Rm.
                             
                                                 
                                             
                                               
     

Chapter 12. Liquid–Liquid and Fluid–Solid Separation
Processes
                             
                                                 
                                             
                                               
     

12.1. INTRODUCTION TO ADSORPTION PROCESSES

12.1A. Intr od u ction

In adsorption processes one or more components of a gas or liquid stream are adsorbed on the surface of a
solid adsorbent and a separation is accomplished. In commercial processes, the adsorbent is usually in
the form of small particles in a fixed bed. The fluid is passed through the bed and the solid particles
adsorb components from the fluid. When the bed is almost saturated, the flow in this bed is stopped and
the bed is regenerated thermally or by other methods so that desorption occurs. The adsorbed material
(adsorbate) is thereby recovered and the solid adsorbent is ready for another cycle of adsorption.

Applications of liquid-phase adsorption include removal of organic compounds from water or organic
solutions, colored impurities from organics, and various fermentation products from fermentor effluents.
Separations include paraffins from aromatics and fructose from glucose using zeolites.

Applications of gas-phase adsorption include removal of water from hydrocarbon gases, sulfur
compounds from natural gas, solvents from air and other gases, and odors from air.

12.1B. Physical Pr op e r tie s of Ad sor b e nts

Many adsorbents have been developed for a wide range of separations. Typically, the adsorbents are in
the form of small pellets, beads, or granules ranging from about 0.1 mm to 12 mm in size, with the larger
particles being used in packed beds. A particle of adsorbent has a very porous structure, with many fine
pores and pore volumes up to 50% of total particle volume. The adsorption often occurs as a monolayer
on the surface of the fine pores, although several layers sometimes occur. Physical adsorption, or van der
Waals adsorption, usually occurs between the adsorbed molecules and the solid internal pore surface and
is readily reversible.

The overall adsorption process consists of a series of steps in series. When the fluid is flowing past the
particle in a fixed bed, the solute first diffuses from the bulk fluid to the gross exterior surface of the
particle. Then the solute diffuses inside the pore to the surface of the pore. Finally, the solute is adsorbed
on the surface. Hence, the overall adsorption process is a series of steps.

There are a number of commercial adsorbents and some of the main ones are described below. All are
characterized by very large pore surface areas of 100 to over 2000 m2/g.

1.  Activated carbon. This is a microcrystalline material made by thermal decomposition of wood,
vegetable shells, coal, and so on, and has surface areas of 300 to 1200 m2/g with average pore
diameters of 10 to 60 Å. Organics are generally adsorbed by activated carbon.

2.  Silica gel. This adsorbent is made by acid treatment of sodium silicate solution and then drying. It
has a surface area of 600 to 800 m2/g and average pore diameters of 20 to 50 Å. It is primarily
used to dehydrate gases and liquids and to fractionate hydrocarbons.

3.  Activated alumina. To prepare this material, hydrated aluminum oxide is activated by heating to
drive off the water. It is used mainly to dry gases and liquids. Surface areas range from 200 to 500
m2/g, with average pore diameters of 20 to 140 Å.

4.  Molecular sieve zeolites. These zeolites are porous crystalline aluminosilicates that form an open
crystal lattice containing precisely uniform pores, which makes it different from other types of
adsorbents, which have a range of pore sizes. Different zeolites have pore sizes from about 3 to 10
Å. Zeolites are used for drying, separation of hydrocarbons, mixtures, and many other
applications.

5.  Synthetic polymers or resins. These are made by polymerizing two major types of monomers.
Those made from aromatics such as styrene and divinylbenzene are used to adsorb nonpolar
organics from aqueous solutions. Those made from acrylic esters are usable with more-polar
solutes in aqueous solutions.

12.1C . Eq u ilib r iu m  R e lations for  Ad sor b e nts

The equilibrium between the concentration of a solute in the fluid phase and its concentration on the
solid resembles somewhat the equilibrium solubility of a gas in a liquid. Data are plotted as adsorption
isotherms as shown in Fig. 12.1-1. The concentration in the solid phase is expressed as q, kg adsorbate
(solute)/kg adsorbent (solid), and in the fluid phase (gas or liquid) as c, kg adsorbate/m3 fluid.

Figure 12.1-1. Some common types of adsorption isotherms.

Data that follow a linear law can be expressed by an equation similar to Henry's law:

Equation 12.1-1

where K is a constant determined experimentally, m3/kg adsorbent. This linear isotherm is not common,
but in the dilute region it can be used to approximate data for many systems.

The Freundlich isotherm equation, which is empirical, often approximates data for many physical
adsorption systems and is particularly useful for liquids:

Equation 12.1-2
where K and n are constants and must be determined experimentally. If a log–log plot is made for q
versus c, the slope is the dimensionless exponent n. The dimensions of K depend on the value of n. This
equation is sometimes used to correlate data for hydrocarbon gases on activated carbon.

The Langmuir isotherm has a theoretical basis and is given by the following, where qo and K are
empirical constants:

Equation 12.1-3

where qo is kg adsorbate/kg solid and K is kg/m3. The equation was derived assuming that there are only
a fixed number of active sites available for adsorption, that only a monolayer is formed, and that the
adsorption is reversible and reaches an equilibrium condition. By plotting 1/q versus 1/c, the slope is
K/qo and the intercept is 1/qo.

Almost all adsorption systems show that as temperature is increased, the amount adsorbed by the
adsorbent decreases strongly. This is useful since adsorption is normally at room temperatures and
desorption can be attained by raising the temperature.

EXAMPLE 12.1-1. Adsorption Isotherm for Phenol in
Wastewater
Batch tests were performed in the laboratory using solutions of phenol in water and particles
of granular activated carbon (R5). The equilibrium data at room temperature are shown in
Table 12.1-1. Determine the isotherm that fits the data.

Table 12.1-1. Equilibrium Data for Example 12.1-1 (R5)

0.322 0.150

0.117 0.122
0.039 0.094

0.0061 0.059
0.0011 0.045

S olu t ion: Plotting the data as 1/q versus 1/c, the results are not a straight line and do not
follow the Langmuir equation (12.1-3). A plot of log q versus log c in Fig. 12.1-2 gives a straight
line and, hence, follows the Freundlich isotherm, Eq. (12.1-2). The slope n is 0.229 and the
constant K is 0.199, to give
Figure 12.1-2. Plot of data for Example 12.1-1.
                             
                                                 
                                             
                                               
     

12.2. BATCH ADSORPTION
Batch adsorption is often used to adsorb solutes from liquid solutions when the quantities treated are
small in amount, as in the pharmaceutical or other industries. As with many other processes, an
equilibrium relation such as the Freundlich or Langmuir isotherm and a material balance are needed.
The initial feed concentration is cF and the final equilibrium concentration is c. Also, the initial
concentration of the solute adsorbed on the solid is qF and the final equilibrium value is q. The material
balance on the adsorbate is

Equation 12.2-1

where M is the amount of adsorbent, kg; and S is the volume of feed solution, m3.

When the variable q in Eq. (12.2-1) is plotted versus c, the result is a straight line. If the equilibrium
isotherm is also plotted on the same graph, the intersection of both lines gives the final equilibrium
values of q and c.

EXAMPLE 12.2­1. Batch Adsorption on Activated Carbon
A wastewater solution having a volume of 1.0 m3 contains 0.21 kg phenol/m3 of solution (0.21
g/L). A total of 1.40 kg of fresh granular activated carbon is added to the solution, which is
then mixed thoroughly to reach equilibrium. Using the isotherm from Example 12.1-1, what
are the final equilibrium values, and what percent of phenol is extracted?

S olu t ion: The given values are cF = 0.21 kg phenol/m3, S = 1.0 m3, M = 1.40 kg carbon, and
qF is assumed as zero. Substituting into Eq. (12.2-1),

This straight-line equation is plotted in Fig. 12.2-1. The isotherm from Example 12.1-1 is also
plotted in Fig. 12.2-1. At the intersection, q = 0.106 kg phenol/kg carbon and c = 0.062 kg
phenol/m3. The percent of phenol extracted is

Figure 12.2-1. Solution to Example 12.2-1.
                             
                                                 
                                             
                                               
     

12.3. DESIGN OF FIXED­BED ADSORPTION COLUMNS

12.3A. Intr od u ction and  C once ntr ation Pr ofile s

A widely used method for adsorption of solutes from liquid or gases employs a fixed bed of granular
particles. The fluid to be treated is usually passed down through the packed bed at a constant flow rate.
The situation is more complex than that for a simple stirred-tank batch process which reaches
equilibrium. Mass-transfer resistances are important in the fixed-bed process, and the process is
unsteady state. The overall dynamics of the system determine the efficiency of the process, rather than
just the equilibrium considerations.

The concentrations of the solute in the fluid phase and of the solid adsorbent phase change with time and
with position in the fixed bed as adsorption proceeds. At the inlet to the bed, the solid is assumed to
contain no solute at the start of the process. As the fluid first comes in contact with the inlet of the bed,
most of the mass transfer and adsorption takes place here. As the fluid passes through the bed, the
concentration in this fluid drops very rapidly with distance in the bed and reaches zero well before the
end of the bed is reached. The concentration profile at the start at time t 1 is shown in Fig. 12.3-1a, where
the concentration ratio c/co is plotted versus bed length. The fluid concentration co is the feed
concentration and c is the fluid concentration at a point in the bed.

Figure 12.3-1. Concentr ation profiles for adsorption in a fixed bed: (a) profiles at various positions and times
in the bed, (b) breakthrough concentr ation profile in the fluid at outlet of bed.
After a short time, the solid near the entrance to the tower is almost saturated, and most of the mass
transfer and adsorption now takes place at a point slightly farther from the inlet. At a later time t 2, the
profile or mass-transfer zone where most of the concentration change takes place has moved farther down
the bed. The concentration profiles shown are for the fluid phase. Concentration profiles for the
concentration of adsorbates on the solid would be similar. The solid at the entrance would be nearly
saturated, and this concentration would remain almost constant down to the mass-transfer zone, where
it would drop off rapidly to almost zero. The dashed line for time t 3 shows the concentration in the fluid
phase in equilibrium with the solid. The difference in concentrations is the driving force for mass transfer.

12.3B. Br e akthr ou gh C once ntr ation C u r v e

As seen in Fig. 12.3-1a, the major part of the adsorption at any time takes place in a relatively narrow
adsorption or mass-transfer zone. As the solution continues to flow, this mass-transfer zone, which is S-
shaped, moves down the column. At a given time t 3 in Fig. 12.3-1a, when almost half of the bed is
saturated with solute, the outlet concentration is still approximately zero, as shown in Fig. 12.3-1b. This
outlet concentration remains near zero until the mass-transfer zone starts to reach the tower outlet at
time t 4. Then the outlet concentration starts to rise, and at t 5 the outlet concentration has risen to cb,
which is called the break point.

After the break-point time is reached, the concentration c rises very rapidly up to point cd, which is the
end of the breakthrough curve, where the bed is judged ineffective. The break-point concentration
represents the maximum that can be discarded and is often taken as 0.01 to 0.05 for cb/co. The value
cd/co is taken as the point where cd is approximately equal to co.

For a narrow mass-transfer zone, the breakthrough curve is very steep and most of the bed capacity is
used at the break point. This makes efficient use of the adsorbent and lowers energy costs for
regeneration.

If the mass-transfer rate were infinitely fast and if no axial dispersion were present, the mass-transfer-
zone width would be zero and the breakthrough curve would be a vertical line from c/co = 0 to c/co = 1.0.

12.3C . M ass-Tr ansfe r  Zone

As shown in Fig. 12.3-1a, on entering the bed the concentration profile in the fluid starts to develop. For
systems with a favorable isotherm, similar to the Freundlich and Langmuir isotherms (Fig. 12.1-1),
which are concave downward (L1), the concentration profile in the mass-transfer zone soon acquires the
typical S shape of the mass-transfer zone. Then the mass-transfer zone is constant in height as it moves
through the column.

This constant height of the mass-transfer zone can then be used in scale-up when the height of the overall
bed is large relative to the mass-transfer zone (L1, T1). Many industrial applications fall within these
restrictions, which are applicable to adsorption from gases and liquids. Note that if the isotherm is linear
or an unfavorable isotherm, the mass-transfer-zone width increases with bed length. A favorable
isotherm for adsorption is unfavorable for effective regeneration (P4).

12.3D. C ap acity of C olu m n and  S cale -Up  De sign M e thod

The mass-transfer-zone width and shape depend on the adsorption isotherm, flow rate, mass-transfer
rate to the particles, and diffusion in the pores. A number of theoretical methods have been published
which predict the mass-transfer zone and concentration profiles in the bed. The predicted results may be
inaccurate because of many uncertainties due to flow patterns and correlations for predicting diffusion
and mass transfer. Hence, experiments in laboratory scale are needed in order to scale up the results.

The total or stoichiometric capacity of the packed-bed tower, if the entire bed comes to equilibrium with
the feed, can be shown to be proportional to the area between the curve and a line at c/co = 1.0, as shown
in Fig. 12.3-2. The total shaded area represents the total or stoichiometric capacity of the bed as follows
(R6):

Equation 12.3-1

Figure 12.3-2. Determination of capacity of column from breakthrough curve.
where t t is the time equivalent to the total or stoichiometric capacity. The usable capacity of the bed up to
the break-point time t b is the crosshatched area:

Equation 12.3-2

where t u is the time equivalent to the usable capacity or the time at which the effluent concentration
reaches its maximum permissible level. The value of t u is usually very close to that of t b. Numerical
integration of Eqs. (12.3-1) and (12.3-2) can be done using a spreadsheet.

The ratio t u/t t is the fraction of the total bed capacity or length utilized up to the break point (C3, L1, M1).


Hence, for a total bed length of HT m, HB is the length of bed used up to the break point,

Equation 12.3-3

The length of unused bed HUNB in m is then the unused fraction times the total length:

Equation 12.3-4

The HUNB represents the mass-transfer section or zone. It depends on the fluid velocity and is essentially
independent of total length of the column. The value of HUNB may, there fore, be measured at the design
velocity in a small-diameter laboratory column packed with the desired adsorbent. Then the full-scale
adsorber bed can be designed simply by first calculating the length of bed needed to achieve the required
usable capacity, HB, at the break point. The value of HB is directly proportional to t b.Then the length
HUNB of the mass-transfer section is simply added to the length HB needed to obtain the total length,
HT:

Equation 12.3-5

This design procedure is widely used; its validity depends on the conditions in the laboratory column
being similar to those for the full-scale unit. The small-diameter unit must be well insulated to be similar
to the large-diameter tower, which operates adiabatically. The mass velocity in both units must be the
same and the bed must be of sufficient length to contain a steady-state mass-transfer zone (L1). Axial
dispersion or axial mixing may not be exactly the same in both towers, but if caution is exercised, this is a
useful design method.

An approximate alternative procedure to use instead of integrating and obtaining areas is to assume that
the breakthrough curve in Fig. 12.3-2 is symmetrical at c/co = 0.5 and t s. Then the value of t t in Eq. (12.3-
1) is simply t s. This assumes that the area below the curve between t b and t s is equal to the area above the
curve between t s and t d.

EXAMPLE 12.3-1. Scale-Up of Laboratory Adsorption
Column
A waste stream of alcohol vapor in air from a process was adsorbed by activated carbon
particles in a packed bed having a diameter of 4 cm and length of 14 cm containing 79.2 g of
carbon. The inlet gas stream having a concentration co of 600 ppm and a density of 0.00115

g/cm3 entered the bed at a flow rate of 754 cm3/s. Data in Table 12.3-1 give the concentrations
of the breakthrough curve. The break-point concentration is set at c/co = 0.01. Do as follows:

a.  Determine the break-point time, the fraction of total capacity used up to the break
point, and the length of the unused bed. Also determine the saturation loading capacity
of the carbon.

b.  If the break-point time required for a new column is 6.0 h, what is the new total length
of the column required?

Table 12.3-1. Breakthrough Concentration for Example 12.3-1

Time, h c/c o Time, h c/c o

0 0 5.5 0.658
3 0 6.0 0.903

3.5 0.002 6.2 0.933


4 0.030 6.5 0.975

4.5 0.155 6.8 0.993


5 0.396    
S olu t ion: The data from Table 12.3-1 are plotted in Fig. 12.3-3.For part (a), for c/co = 0.01,
the break-point time is t b = 3.65 h from the graph.The value of t d is approximately 6.95
h.Numerically or graphically integrating, the areas are A1 = 3.65 h and A2 = 1.51 h.Then from
Eq. (12.3-1), the time equivalent to the total or stoichiometric capacity of the bed is

Figure 12.3-3. Breakthrough curve for Example 12.3-1.

The time equivalent to the usable capacity of the bed up to the break-point time is, using Eq.
(12.3-2),

Hence, the fraction of total capacity used up to the break point is t u/t t = 3.65/5.16 = 0.707.


From Eq. (12.3-3) the length of the used bed is HB = 0.707(14) = 9.9 cm. To calculate the
length of the unused bed from Eq. (12.3-4),
For part (b), for a new t b of 6.0 h, the new HB is obtained simply from the ratio of the break-
point times multiplied by the old HB:

We determine the saturation capacity of the carbon:

The fraction of the new bed used up to the break point is now 16.3/20.4, or 0.799.

In the scale-up, not only may it be necessary to change the column height, but also the actual
throughput of fluid might be different from that used in the experimental laboratory unit.Since the mass
velocity in the bed must remain constant for scale-up, the diameter of the bed should be adjusted to keep
it constant.

Typical gas adsorption systems use heights of fixed beds of about 0.3 to 1.5 m with downflow of the gas.
Low superficial gas velocities of 15–50 cm/s (0.5–1.7 ft/s) are used. Adsorbent particle sizes range from
about 4 to 50 mesh (0.3 to 5 mm). Pressure drops are low, only a few inches of water per foot of bed. The
adsorption time is about 0.5 h up to 8 h. For liquids the superficial velocity of the liquid in the bed is
about 0.3 to 0.7 cm/s (4 to 10 gpm/ft 2).

Practical bed depths usually need to be 5–10 times the length of bed of the mass-transfer zone to be
economical (W1). The adsorption step usually uses downward flow in the bed. For desorption the flow is
usually upward for greater efficiency (S3).

12.3E. Basic M od e ls for  Pr e d icting Ad sor p tion

Adsorption in fixed beds is the most important method used for this process. A fixed or packed bed
consists of a vertical cylindrical pipe filled or packed with the adsorbent particles. Adsorbers are mainly
designed using laboratory data and the methods described in Section 12.3D. In this section, the basic
equations for isothermal adsorption are described so that the fundamentals involved in this process can
be better understood.

An unsteady-state solute material balance in the fluid is as follows for a section dz length of bed:

Equation 12.3-6

where ε is the external void fraction of the bed; ν is superficial velocity in the empty bed, m/s; ρp is

density of particle, kg/m3; and E is an axial dispersion coefficient, m2/s. The first term represents
accumulation of solute in the liquid. The second term is accumulation of solute in the solid. The third
term represents the amount of solute flowing in by convection to the section dz of the bed minus that
flowing out. The last term represents axial dispersion of solute in the bed, which leads to mixing of the
solute and solvent.

The second differential equation needed to describe this process relates the second term of Eq. (12.3-6) for
accumulation of solute in the solid to the rate of external mass transfer of the solute from the bulk
solution to the particle and the diffusion and adsorption on the internal surface area. The actual physical
adsorption is very rapid. The third equation is the equilibrium isotherm.

There are many solutions for these three equations which are nonlinear and coupled. These solutions
frequently do not fit experimental results very well and will not be discussed here.

12.3F. Pr oce ssing Var iab le s and  Ad sor p tion C ycle s

Large-scale adsorption processes can be divided into two broad classes. The first and most important is
the cyclic batch system, in which the adsorption fixed bed is alternately saturated and then regenerated
in a cyclic manner. The second is a continuous flow system, which involves a continuous flow of
adsorbent countercurrent to a flow of feed.

There are four basic methods in common use for the cyclic batch adsorption system using fixed beds.
These methods differ from each other mainly in the means used to regenerate the adsorbent after the
adsorption cycle. In general, these four basic methods operate with two or sometimes three fixed beds in
parallel, one in the adsorption cycle and the other one or two in a desorbing cycle, to provide continuity
of flow. After a bed has completed the adsorption cycle, the flow is switched to the second newly
regenerated bed for adsorption. The first bed is then regenerated by any of the following methods.

1.  Temperature-swing cycle. This is also called the thermal-swing cycle. The spent adsorption bed is
regenerated by heating it with embedded stream coils or with a hot purge gas stream to remove the
adsorbate. The elevation in temperature is used to shift the adsorption equilibrium curve and
affect regeneration of the adsorbent. Finally, the bed must be cooled so that it can be used for
adsorption in the next cycle. The time for regeneration is generally a few hours or more.

2.  Pressure-swing cycle. In this case the bed is desorbed by reducing the pressure at essentially
constant temperature and then purging the bed at this low pressure with a small fraction of the
product stream. Reduction in pressure shifts the adsorption equilibrium and affects the
regeneration of the adsorbent. This process for gases uses a very short cycle time for regeneration
compared to that for the temperature-swing cycle.

3.  Inert-purge gas stripping cycle. In this cycle the adsorbate is removed by passing a nonadsorbing
or inert gas through the bed. This lowers the partial pressure or concentration around the particles
and desorption occurs. Regeneration cycle times are usually only a few minutes.

4.  Displacement-purge cycle. The pressure and temperature are kept essentially constant as in
purge-gas stripping, but a gas or liquid is used that is adsorbed more strongly than the adsorbate
and displaces the adsorbate. Again, cycle times are usually only a few minutes.

Steam stripping is often used in regeneration of solvent-recovery systems using activated-carbon
adsorbent. This can be considered a combination of the temperature-swing cycle and the displacement-
purge cycle.
                             
                                                 
                                             
                                               
     

12.4. ION­EXCHANGE PROCESSES

12.4 A. Intr od u ction and  Ion-Exchange  M ate r ials

Ion-exchange processes are basically chemical reactions between ions in solution and ions in an insoluble
solid phase. The techniques used in ion exchange so closely resemble those used in adsorption that for
the majority of engineering purposes ion exchange can be considered as a special case of adsorption.

In ion exchange, certain ions are removed by the ion-exchange solid. Since electroneutrality must be
maintained, the solid releases replacement ions to the solution. The first ion-exchange materials were
natural-occurring porous sands called zeolites, which are cation exchangers. Positively charged ions in
solution such as Ca2+ diffuse into the pores of the solid and exchange with the Na+ ions in the mineral:

Equation 12.4-1

where R represents the solid. This is the basis for “softening” water. To regenerate, a solution of NaCl is
added, which drives the reversible reaction above to the left. Almost all of these inorganic ion-exchange
solids exchange only cations.

Most present-day ion-exchange solids are synthetic resins or polymers. Certain synthetic polymeric
resins contain sulfonic, carboxylic, or phenolic groups. These anionic groups can exchange cations:

Equation 12.4-2

Here R represents the solid resin. The Na+ in the solid resin can be exchanged with H+ or other cations.

Similar synthetic resins containing amine groups can be used to exchange anions and OH– in solution:

Equation 12.4-3

12.4 B. Eq u ilib r iu m  R e lations in Ion Exchange


The ion-exchange isotherms have been developed using the law of mass action. For example, for the case
of a simple ion-exchange reaction such as Eq. (12.4-2), HR and NaR represent the ion-exchange sites on
the resin filled with a proton H+ and a sodium ion Na+. It is assumed that all of the fixed number of sites
are filled with H+ or Na+. At equilibrium,

Equation 12.4-4

Since the total concentration of the ionic groups   on the resin is fixed (B7),

Equation 12.4-5

Combining Eqs. (12.4-4) and (12.4-5),

Equation 12.4-6

If the solution is buffered, so that [H+] is constant, the above equation for sodium exchange or
adsorption is similar to the Langmuir isotherm.

The ion-exchange process functions for strong acid or strong base exchangers by replacing the ions of a
solution with ions such as H+ or OH−. These replaced ions from the solution are taken up by the resin.
Then, to regenerate the resin, a small amount of solution with a high concentration of H+ is used for
cation exchangers or a high concentration of OH− ions for anion exchangers. These high concentrations
of H+ or OH− for regeneration shift the equilibrium to the left, making the regeneration process more
favorable.

A typical ion-exchange process for removal of metals from solution is shown for copper cation being
removed from a stream containing dilute CuSO4 and H2SO4:

Equation 12.4-7

For regeneration, the bed of resin is contacted with a high concentration of H2SO4 to shift the equilibrium
to the left.

12.4 C . Use  of Eq u ilib r iu m  R e lations and  R e lativ e -M olar -S e le ctiv ity C oe fficie nts

Convenient tables for relative-molar-selectivity coefficients K have been prepared for various types of ion-
exchange resins. Data are given in Table 12.4-1 for a polystyrene resin with 8% divinylbenzene (DVB)
cross-linking (B8, P4) for strong-acid and strong-base resins. For cation exchangers, values are given for
cation A entering the resin and displacing the cation Li+, and for anion exchangers, values for anion A
replacing Cl−.

Table 12.4-1. Relative-Molar-Selectivity Coefficients K for Polystyrene Cation and Anion
Exchangers with 8% DVB Cross-Linking (B8, P4)

Strong-Base Anion Exchanger  (Relative to Cl− Strong-Acid Cation Exchanger  (Relative to Li+


as 1.0) as 1.0)
Cl− 1.0 Li+ 1.0

Iodide 8.7 H+ 1.27

Nitrate 3.8 Na+ 1.98

Acetate 0.2 2.55

Sulfate 0.15 K+ 2.90

Hydroxide 0.05–0.07 Mg2+ 3.29

    Cu2+ 3.85

    Ca2+ 5.16

The equilibrium constant or selectivity coefficient for exchange of any two ions A and B can be
approximated from Table 12.4-1 using values of KA and KB:

Equation 12.4-8

For example, for the reaction of cation K+ (A) displacing cation H+ (B),

Equation 12.4-9

Substituting into Eq. (12.4-8), KA,B = KA/KB = 2.90/1.27 = 2.28.

For dilute solutions, activity coefficients are relatively constant and simple concentration units are used.
For Eq. (12.4-9), the equilibrium constant is as follows:
Equation 12.4-10

where, for the resin phase, concentrations qKR and qHR are in equivalents/L of bulk bed volume of water-

swelled resin, and for the liquid phase, concentrations   and   are in equivalents/L of volume of


solution.

The total concentration C in the liquid solution and the total concentration Q in the resin remain
constant during the exchange process because of electroneutrality in Eq. (12.4-9). Then,

Equation 12.4-11

In the case of Eq. (12.4-7), where the ion Cu2+ (A) replaces H+ (B) and the charges are unequal,

Equation 12.4-12

EXAMPLE 12.4-1. Removal of Cu 2+ Ion from Acid Solution
by an Ion-Exchange Resin
A waste acidic stream contains copper in solution which is being removed by a strong acid–
cation resin. The cation Cu2+ (A) is displacing the cation H+ (B) in the resin. A polystyrene
resin similar to that in Table 12.4-1 is being used. The total resin capacity Q is approximately
1.9 equivalents/L of wet bed volume. For a total concentration C of 0.10 N (0.10 equivalents/L)
in the solution, calculate at equilibrium the total equivalents of Cu2+ in the resin when the
concentration of Cu2+ in solution is 0.02 M (0.04 N).

S olu t ion: The known values are C = 0.10 N or equivalents/L of Cu2+ (A) and H+ (B) in
solution and Q = 1.9 equivalents/L of A and B in the resin. The equilibrium relation is Eq.
(12.4-7):
or,

From Table 12.4-1, KA =   = 3.85 and KB =   = 1.27. Then, from Eq. (12.4-8),

Using Eq. (12.4-12),

From Eq. (12.4-11), C = 0.10 equivalents/L =   +  . Also, Q = 1.9 = qHR +  .

The values to substitute into Eq. (12.4-12) are KA,B = 3.03,   = 1.9/2 −   =

0.02, and   = 0.10 −   = 0.10 − 0.04 = 0.06.

Rearranging,

Solving this quadratic equation, qHR = 0.2232. Then   = 1.9/2 − 0.2232/2 = 0.8384.

Hence, the equivalents of Cu2+ in the resin is 2(0.8384) = 1.677 compared to a value of 1.9
when fully loaded with copper. The result shows that the removal of Cu2+ from the solution by
the resin is highly favored.
12.4 D. C once ntr ation Pr ofile s and  Br e akthr ou gh C u r v e s

1. Ba sic mod els in ion excha ng e

The rate of ion exchange depends on mass transfer of ions from the bulk solution to the particle surface,
diffusion of the ions in the pores of the solid to the surface, exchange of the ions at the surface, and
diffusion of the exchange ions back to the bulk solution. This is similar to adsorption. The differential
equations derived are also very similar to those for adsorption. The design methods used for ion exchange
and adsorption are similar.

2. C oncent r a t ion p r ofiles in p a ck ed  b ed s

Concentration profiles in packed beds for ion exchangers are very similar to those given in Fig. 12.3-1a for
adsorption. The typical S-shaped curves occur and pass through the bed. The major part of the ion
exchange at any time takes place in a relatively narrow mass-transfer zone. This mass-transfer zone
moves down the column. In Fig. 12.3-1b the breakthrough curve is shown, which is similar for adsorption
and ion exchange.

3. M a ss-t r a nsfer  zone

As the mass-transfer zone travels down the column, the height of this zone becomes constant. This
behavior is generally characteristic in cases where the ion to be removed from the feed stream has a
greater affinity for the solid resin than the ion originally present in the solid. The majority of industrial
ion-exchange processes fall in this category (M1). This constant height of the mass-transfer zone can then
be used for scale-up, similar to adsorption scale-up.

12.4 E. C ap acity of C olu m ns and  S cale -Up  De sign M e thod

1. C a p a cit y  of colu mn

The design method for fixed-bed ion exchangers is quite similar to that used for adsorption processes.
Theoretical predictions of concentration profiles, the mass-transfer zone, and mass transfer may be
inaccurate because of uncertainties due to flow patterns, and so forth. Hence, experiments using small
packed-bed laboratory-scale columns are needed for scale-up.

The total stoichiometric capacity of the packed bed is the total shaded area in the breakthrough curve in
Fig. 12.3-2. The time t t is the time equivalent to the total capacity:

Equation 12.3-1

The usable capacity up to the break-point time t b is the cross-hatched area from t = 0 to t b. Then t u, the


time equivalent to the usable capacity, is

Equation 12.3-2
Numerical integration of Eqs. (12.3-1) and (12.3-2) can also be done using spreadsheets. Then the
fraction of the total bed length or capacity utilized up to the break point is t u/t t. For a total bed length of
HT m, HB is the length of the bed used up to the break point:

Equation 12.3-3

The length of the mass-transfer section or unused bed HUNB in m is then

Equation 12.3-4

This HUNB is essentially independent of the total column length. The experimental value of HUNB is
measured at the desired velocity in a small-diameter laboratory column. To design the full-scale column,
the length of the bed HB is calculated to achieve the desired capacity at the break point. Then the total
column length is

Equation 12.3-5

The mass velocity of both the laboratory- and full-scale columns must be the same. The diameter of the
large-scale column is calculated using the same given mass velocity.

2. Ty p ica l p r ocess v a r ia b les

Some typical operating process variables are as follows. The laboratory column should be at least 2.5 cm
in diameter and 0.3 m in length. Liquid flow rates commercially (W1) can be from 1 to 12 gpm/ft 2
(0.041–0.489 m/min) but are usually 6–8 gpm/ft 2 (0.244–0.326 m/min). Commercial columns are
usually 1–3 m in height. Usually a freeboard of 50% or more open space is needed to accommodate bed
expansion when regenerant flow is upward.

The resin gel can swell due to exchange by about 10 to 20%. Particle sizes used range from 0.2 mm to 1.0
mm. Typical moisture contents of the resins vary from 50 to 70%. The equilibrium exchange capacities of
strong-acid or -base exchange resins are typically 3–5 meq/g of dry resin and 1–2 meq/ml of wet resin
bed.

Regeneration flow rates are typically quite low, in the range of 0.5 to 5.0 bed volumes/h, in order to attain
equilibrium while using minimum amounts of solution (W1). A bed volume is the total volume of the
packed bed of resin as calculated from the column diameter and height of the packed bed.

Pressure drop can be predicted by using the equations for flow in packed beds. Typical pressure drops for
beds are about 0.6 to 0.9 psi/ft height (13.6–20.4 kPa/m height) for flow rates of 6 to 8 gpm/ft 2.
Excessive pressure drops should be avoided, since the gel-resin particles can be deformed.

A useful method for correlating experimental breakthrough curves at different flow velocities and the
mass-transfer zone is as follows: Instead of plotting c/co versus time t, as in Fig. 12.3-1b, a plot of c/co
versus the number of bed volumes (BV) is made. Data for different flow velocities will then tend to fall on
the same curve.

3. Op er a t ing  cy cles

The operating cycles for ion-exchange processes in a packed bed are more complicated than those for gas
adsorption. These usually consist of the following four steps, with experimental data usually needed to
define each operating time (S3, W1). (1) Downflow loading of the process feed for a proper time. At the
end of loading, the bed voids are filled with feed solution. (2) Displacement of the feed solution with
upward flow of the regeneration solution. Thus, displacement of the occluded feed solution first occurs as
a wave front. (3) Regeneration of the bed with continued upward flow of the regeneration solution. This
occurs as a second wavefront. (4) Rinse upward to remove occluded regenerant from the bed. A rinse can
be used instead of step (2) for recovering possibly valuable occluded process solution (W1).

For the actual design and for continuous feed flow, at least two columns are needed, so that one column
is used to process the feed while the other is used for regeneration. When breakthrough occurs, the towers
are switched. The total number of beds depends on the loading and regeneration times. Alternatively, a
three-column system can be used for better utilization of the columns. The feed enters column 2 and then
column 3 in series while column 1 is being regenerated. When breakthrough occurs in column 3, column 2
is removed for regeneration. The feed is then rerouted and goes to column 3 and then to column 1.
                             
                                                 
                                             
                                               
     

12.5. SINGLE­STAGE LIQUID–LIQUID EXTRACTION PROCESSES

12.5A. Intr od u ction to Extr action Pr oce sse s

In order to separate one or more of the components in a mixture, the mixture is brought into contact with
another phase. The two-phase pair can be gas–liquid, which was discussed in Chapter 10; vapor–liquid,
which was covered in Chapter 11; liquid–liquid; or fluid–solid. In this section liquid–liquid extraction
separation processes are considered first. Alternative terms for the same process are liquid extraction or
solvent extraction.

In distillation, the liquid is partially vaporized to create another phase, which is a vapor. The separation
of the components depends on the relative vapor pressures of the substances. The vapor and liquid
phases are similar chemically. In liquid–liquid extraction, the two phases are chemically quite different,
which leads to a separation of the components according to physical and chemical properties.

Solvent extraction can sometimes be used as an alternative to separation by distillation or evaporation.
For example, acetic acid can be removed from water by distillation or by solvent extraction using an
organic solvent. The resulting organic solvent–acetic acid solution is then distilled. Choice of distillation
or solvent extraction would depend on relative costs (C7). In another example, high-molecular-weight
fatty acids can be separated from vegetable oils by extraction with liquid propane or by high-vacuum
distillation, which is more expensive.

In the pharmaceutical industry, products such as penicillin occur in fermentation mixtures that are quite
complex, and liquid extraction can be used to separate the penicillin. Many metal separations are being
done commercially by extraction of aqueous solutions, such as copper–iron, uranium–vanadium, and
tantalum–columbium.

12.5B. Eq u ilib r iu m  R e lations in Extr action

1. Pha se r u le

Generally in a liquid–liquid system we have three components, A, B, and C, and two phases in
equilibrium. Substituting into the phase rule, Eq. (10.2-1), the number of degrees of freedom is 3. The
variables are temperature, pressure, and four concentrations. Four concentrations occur because only two
of the three mass-fraction concentrations in a phase can be specified. The third must make the total mass
fractions equal to 1.0: xA + xB + xC = 1.0. If pressure and temperature are set, which is the usual case,
then, at equilibrium, setting one concentration in either phase fixes the system.

2. Tr ia ng u la r  coor d ina t es a nd  eq u ilib r iu m d a t a

Equilateral triangular coordinates are often used to represent the equilibrium data for a three-component
system, since there are three axes. This is shown in Fig. 12.5-1. Each of the three corners represents a pure
component, A, B, or C. The point M represents a mixture of A, B, and C. The perpendicular distance from
the point M to the base AB represents the mass fraction xC of C in the mixture at M, the distance to base
CB the mass fraction xA of A, and the distance to base AC the mass fraction xB of B. Thus,
Equation 12.5-1

Figure 12.5-1. Coordinates for a triangular diagram.

A common phase diagram where a pair of components A and B are partially miscible is shown in Fig.
12.5-2. Typical examples are methyl isobutyl ketone (A)–water (B)–acetone (C), water (A)–chloroform
(B)–acetone (C), and benzene (A)–water (B)–acetic acid (C). Referring to Fig. 12.5-2, liquid C dissolves
completely in A or in B. Liquid A is only slightly soluble in B and B slightly soluble in A. The two-phase
region is included inside below the curved envelope. An original mixture of composition M will separate
into two phases a and b which are on the equilibrium tie line through point M. Other tie lines are also
shown. The two phases are identical at point P, the Plait point.

Figure 12.5-2. Liquid–liquid phase diagram where components A and B are partially miscible.
3. Eq u ilib r iu m d a t a  on r ect a ng u la r  coor d ina t es

Since triangular diagrams have some disadvantages due to the special coordinates, a more useful
method of plotting the three-component data is to use rectangular coordinates. This is shown in Fig.
12.5-3 for the system acetic acid (A)–water (B)–isopropyl ether solvent (C). Data for this system are from
Appendix A.3. The solvent pair B and C are partially miscible. The concentration of component C is
plotted on the vertical axis and that of A on the horizontal axis. The concentration of component B is
obtained by difference from Eq. (12.5-2) or (12.5-3):

Equation 12.5-2

Equation 12.5-3

Figure 12.5-3. Acetic acid (A)–water (B)–isopropyl ether (C) liquid–liquid phase diagram at 293 K (20°C).
The two-phase region in Fig. 12.5-3 is inside the envelope and the one-phase region outside. A tie line gi
is shown connecting the water-rich layer i, called the raffinate layer, and the ether-rich solvent layer g,
called the extract layer. The raffinate composition is designated by x and the extract by y. Hence, the
mass fraction of C is designated as y C in the extract layer and as xC in the raffinate layer. To construct the
tie line gi using the equilibrium y A − xA plot below the phase diagram, vertical lines to g and i are drawn.

EXAMPLE 12.5-1. Material Balance for Equilibrium Layers
An original mixture weighing 100 kg and containing 30 kg of isopropyl ether (C), 10 kg of
acetic acid (A), and 60 kg water (B) is equilibrated and the equilibrium phases separated.
What are the compositions of the two equilibrium phases?

S olu t ion: The composition of the original mixture is xC = 0.30, xA = 0.10, and xB = 0.60.
This composition of xC = 0.30 and xA = 0.10 is plotted as point h on Fig. 12.5-3. The tie line gi
is drawn through point h by trial and error. The composition of the extract (ether) layer at g is
y A = 0.04, y C = 0.94, and y B = 1.00 − 0.04 − 0.94 = 0.02 mass fraction. The raffinate (water)-
layer composition at i is xA = 0.12, xC = 0.02, and xB = 1.00 − 0.12 − 0.02 = 0.86.

Another common type of phase diagram is shown in Fig. 12.5-4, where the solvent pairs B and C and A
and C are partially miscible. Examples are the system styrene (A)–ethylbenzene (B)–diethylene glycol
(C) and the system chlorobenzene (A)–methyl ethyl ketone (B)–water (C).

Figure 12.5-4. Phase diagram where the solvent pairs B–C and A–C are partially miscible.

12.5C . S ingle -S tage  Eq u ilib r iu m  Extr action

1. Der iv a t ion of lev er -a r m r u le for  g r a p hica l a d d it ion

This will be derived for use with the rectangular extraction-phase-diagram charts. In Fig. 12.5-5a two
streams, L kg and V kg, containing components A, B, and C, are mixed (added) to give a resulting
mixture stream M kg total mass. Writing an overall mass balance and a balance on A,

Equation 12.5-4

Equation 12.5-5

where xAM is the mass fraction of A in the M stream. Writing a balance for component C,

Equation 12.5-6

Combining Eqs. (12.5-4) and (12.5-5),

Equation 12.5-7
Figure 12.5-5. Graphical addition and lever-arm rule: (a) process flow, (b) graphical addition.

Combining Eqs. (12.5-4) and (12.5-6),

Equation 12.5-8

Equating Eqs. (12.5-7) and (12.5-8) and rearranging,

Equation 12.5-9

This shows that points L, M, and V must lie on a straight line. By using the properties of similar right
triangles,

Equation 12.5-10

This is the lever-arm rule, which states that kg L/kg V is equal to the length of line  /length of line 
. Also,

Equation 12.5-11
These same equations also hold for kg mol and mol frac, lbm, and so on.

EXAMPLE 12.5-2. Amounts of Phases in Solvent
Extraction
The compositions of the two equilibrium layers in Example 12.5-1 are for the extract layer (V),
y A = 0.04, y B = 0.02, and y C = 0.94, and for the raffinate layer (L), xA = 0.12, xB = 0.86, and
xC = 0.02. The original mixture contained 100 kg and xAM = 0.10. Determine the amounts of V
and L.

S olu t ion: Substituting into Eq. (12.5-4),

Substituting into Eq. (12.5-5), where M = 100 kg and xAM = 0.10,

Solving the two equations simultaneously, L = 75.0 and V = 25.0. Alternatively, using the
lever-arm rule, the distance hg in Fig. 12.5-3 is measured as 4.2 units and gi as 5.8 units.
Then, by Eq. (12.5-11),

Solving, L = 72.5 kg and V = 27.5 kg, which is in reasonably close agreement with the material-
balance method.

2. S ing le-st a g e eq u ilib r iu m ext r a ct ion

We now study the separation of A from a mixture of A and B by a solvent C in a single equilibrium stage.
The process is shown in Fig. 12.5-6a, where the solvent, as stream V2, enters together with the stream L0.
The streams are mixed and equilibrated and the exit streams L1 and V1 leave in equilibrium with each
other.

Figure 12.5-6. Single-stage equilibrium liquid—liquid extraction: (a) process flow diagram, (b) plot on phase
diagram.
The equations for this process are the same as those given in Section 10.3 for a single equilibrium stage,
where y represents the composition of the V streams and x the L streams:

Equation 12.5-12

Equation 12.5-13

Equation 12.5-14

Since xA + xB + xC = 1.0, an equation for B is not needed. To solve the three equations, the equilibrium-
phase diagram in Fig. 12.5-6b is used. Since the amounts and compositions of L0 and V2 are known, we
can calculate values of M, xAM, and xCM from Eqs. (12.5-12)–(12.5-14). The points L0, V2, and M can be
plotted as shown in Fig. 12.5-6b. Then, using trial and error, a tie line is drawn through point M, which
locates the compositions of L1 and V1. The amounts of L1 and V1 can be determined by substitution into
Eqs. (12.5-12)–(12.5-14) or by using the lever-arm rule.
                             
                                                 
                                             
                                               
     

12.6. TYPES OF EQUIPMENT AND DESIGN FOR LIQUID–LIQUID
EXTRACTION

12.6 A. Intr od u ction and  Eq u ip m e nt Typ e s

As in the separation processes of absorption and distillation, the two phases in liquid–liquid extraction
must be brought into intimate contact with a high degree of turbulence in order to obtain high mass-
transfer rates. After this contact of the two phases, they must be separated. In both absorption and
distillation, this separation is rapid and easy because of the large difference in density between the gas or
vapor phase and the liquid phase. In solvent extraction, the density difference between the two phases is
not large and separation is more difficult.

There are two main classes of solvent-extraction equipment, vessels in which mechanical agitation is
provided for mixing, and vessels in which the mixing is done by the flow of the fluids themselves. The
extraction equipment can be operated batchwise or continuously as in absorption and in distillation.

12.6 B. M ixe r –S e ttle r s for  Extr action

To provide efficient mass transfer, a mechanical mixer is often used to provide intimate contact between
the two liquid phases. One phase is usually dispersed into the other in the form of small droplets.
Sufficient time of contact should be provided for the extraction to take place. Small droplets produce
large interfacial areas and faster extraction. However, the droplets must not be so small that the
subsequent settling time in the settler is too large.

The design and power requirements for baffled agitators or mixers have been discussed in detail in
Section 3.4. In Fig. 12.6-1a a typical mixer–settler is shown, where the mixer or agitator is entirely
separate from the settler. The feed of aqueous phase and organic phase are mixed in the mixer, and then
the mixed phases are separated in the settler. In Fig. 12.6-1b a combined mixer–settler is shown, which is
sometimes used in the extraction of uranium salts or copper salts from aqueous solutions. Both types of
mixer–settlers can be used in series for countercurrent or multiple-stage extraction. Typical stage
efficiencies for a mixer–settler are 75–100%.

Figure 12.6-1. Typical mixer–settl ers for extr action: (a) separate mixer–settl er, (b) combined mixer–settl er.

[View full size image]
12.6 C . S p r ay Extr action Tow e r s

Packed and spray-tower extractors give differential contact, where mixing and settling proceed
continuously and simultaneously (C8). In the plate-type towers or mixer–settler contactors, the
extraction and settling proceeds in discrete stages. In Fig. 12.6-2 the heavy liquid enters at the top of the
spray tower, fills the tower as the continuous phase, and flows out through the bottom. The light liquid
enters through a nozzle distributor at the bottom, which disperses or sprays the droplets upward. The
light liquid coalesces at the top and flows out. In some cases the heavy liquid is sprayed downward into a
rising, light continuous phase.

Figure 12.6-2. Spray-type extraction tower.

The spray tower has a very large axial dispersion (back-mixing) in the continuous phase. Hence, only one
or two stages are usually present in such a tower. Typical performance parameters for a spray tower are
given in Table 12.6-1. Despite its very low cost, this type of tower is rarely used. It can be used when a
rapid, irreversible chemical reaction occurs, as in neutralization of waste acids (W1).

Table 12.6-1. Typical Performance for Several Types of Commercial Extraction Towers

Capacity of
Combined Approximate Overall
Streams, Flooding, (VD Spacing Height of Plate
Height of
between Equilibrium
(VD + VC), + VC), m 3 /m 2 Stages, Transfer Unit, Efficiency, Stage,
Type m 3 /m 2  ° h ° h T, cm HOL , m EO, % HETS, m Ref.

Spray 15–75     3–6   3–6 M4,


Tower S5
Packed 12–30     0.9–1.7   0.4–1.5 S4,
Tower S5,
W1

Structured 65–90         0.5–1.6 H4


Packing
Tower
Tower

Sieve-Tray 27–60   10–25   8–30 0.8–1.2 M4,


Tower P4,
S4
Pulsed 17–23 40       0.15–0.3 P4,
Packed S4,
Tower W1

Pulsed 25–35 60 5.1     0.15–0.3 S4,


Sieve Tray W1
Tower

Scheibel 10–14[*] 40 2.5–20     0.1–0.3 P4,


Tower S2,
S3,
W1

Karr Tower 30–40 80–100 5–15     0.2–0.6 S2,


S4

[*]
 Throughput for diameter D1 = 7.6 cm. For larger towers of D2 diameter see Eq. (12.6-3).

12.6 D. Packe d  Extr action Tow e r s

A more effective type of tower is made by packing the column with random packing such as Raschig
rings, Berl saddles, Pall rings, and so on, which cause the droplets to coalesce and redisperse at frequent
intervals throughout the tower. The axial mixing is reduced considerably. A packed tower is more
efficient than a spray tower, but back-mixing still occurs and the HETS (height equivalent to a theoretical
stage) is generally greater than for the pulsed and mechanically agitated towers discussed later in
Sections 12.6F and G.

Packed towers are used where only a few stages are needed (S3) and generally with low-interfacial-
tension systems of about 10 dyn/cm or so (W1). When using random packings, it is preferable to choose a
material that is preferentially wetted by the continuous phase. For example, stoneware Raschig rings or
Berl saddles are used for water as the continuous phase and carbon rings or saddles for toluene as the
continuous phase (T2). Packed towers more often use random packing and less often structured packing.
Some typical performance values for packed towers are given in Table 12.6-1.

The few data available for structured packing have similar HETS values as packed or sieve-tray towers
but give higher capacities (H4). The structured packings used for extraction are similar to those used for
distillation.

In packed absorption towers, flooding occurs when the gas velocity is increased until the liquid cannot
flow downward and is carried up by the gas out of the tower. In packed liquid-extraction towers, flooding
occurs when increasing the dispersed or continuous flow rates causes both phases to leave at the outlet of
the continuous phase.

A flooding correlation by Crawford and Wilke (C9) is given in Fig. 12.6-3, where VC and VD are
superficial velocities of continuous and dispersed phases in ft/h, ρC and ρD are densities of continuous

and dispersed phases in lbm/ft 3, Δρis |ρC ¯ρD|, μc is viscosity of continuous phase in lbm/ft · h, a is

specific surface area of packing in ft 2/ft 3 (Table 10.6-1), ε is void fraction of packed section (Table 10.6-1),


and σ is interfacial tension between phases in lbm/h2. Note: 1.0 dyn/cm = 28 572 lbm/h2. It is
recommended that the design flow rates be set at 50% of flooding due to uncertainties in the correlation.

Figure 12.6-3. Flooding correlation for packed extraction towers. [From J. W. Crawford and C. R. Wilke, Chem.
Eng. Prog., 47, 423 (1951). With permission.]

[View full size image]

EXAMPLE 12.6.1. Prediction of Flooding and Packed-
Tower Diameter
Toluene as the dispersed phase is being used to extract diethylamine from a dilute water
solution in a packed tower of 1-in. Pall rings at 26.7°C. The flow rate of toluene V = 84 ft 3/h
and of water solution L = 56 ft 3/ · h. The physical properties of the dilute solutions are: for the
aqueous continuous phase (C), ρC = 62.2 lbm/ft 3, μC = 0.860 cp = 0.860(2.4191) = 2.080

lbm/fth; for the dispersed phase, ρD = 54.0 lbm/ft 3. The interfacial tension σ = 25 dyn/cm (T2).
Do as follows:

a.  Predict the flooding velocity.

b.  Using 50% of flooding, determine the tower diameter.

c.  If the separation requires 5.0 theoretical stages, calculate the tower height.

S olu t ion: For part (a), from Table 10.6-1 for 1-in. Pall rings, the surface area a = 63 ft 2/ft 3


and ε = 0.94 void fraction. Also, σ = (25 dyn/cm)(28 572 lbm/h2)/(dyn/cm) = 714 300 lbm/h2.
Then, for the ordinate in Fig. 12.6-3,
From Fig. 12.6-3, the abscissa value is 170. Hence,

Solving,  . Also, since VD/VC = V/L = 84/56 = 1.5, the final result
gives VD = 108.45 ft/h and VC = 72.30 ft/h for the flooding velocity.

For part (b), using 50% of flooding, VD = 54.2, VC = 36.15 ft/h, and VC + VD = 90.35 ft/h =
90.35/3.2808 = 27.54 m/h. This is still in the typical range given for packed towers in Table
12.6-1 of 12–30 m/h.

The tower cross-sectional area = L/VC = (56 ft 3/h)/(36.15 ft/h) = 1.549 ft 2. Then, πD2/4 =


1.549 and D = 1.404 ft (0.428 m).

For part (c), use the average HETS for packed towers from Table 12.6-1 of (0.4 + 1.5)/2, or 0.95
m (3.117 ft). Then the tower height is (HETS ft/stage) (number of stages) or 3.117(5.0) = 15.58
ft (4.75 m). Adding about 2 ft to the top and bottom for inlet nozzles and settling zones, the
total height = 15.58 + 2 + 2 = 19.58 ft (5.97 m).

To use Fig. 12.6-3, the value of the interfacial tension σ is needed. This is a very important variable for
extraction and can vary from about 5 to 50 dyn/cm. The interfacial tension between immiscible phases
that must be settled must be sufficiently high for rapid coalescence. Also, high values of σ mean that
often extra energy or agitation must be used in the tower for dispersion of one phase in the other.
However, too low a value may result in too-slow coalescence or stable emulsions.

To estimate the interfacial tension of a two-phase system when experimental data are not available, Eq.
(12.6-1) can be used for type one ternary systems, with an average deviation of about ±15% (T2):

Equation 12.6-1

where σ is the interfacial tension in dyn/cm, xAB is the mole fraction of solvent A in the saturated
solvent-rich B layer, xBA is the mole fraction of B in the saturated solvent-rich A layer, xCA is the mole
fraction of the distributed solute C in A, and xCB is the mole fraction of solute C in B. This equation holds
only for a range of values for [xAB + xBA + (xCA + xCB)/2] between 0.0004 and 0.30. A value of 1.0
indicates complete solution of the phases at the plait point. The range of σ values is 4–52.5 dyn/cm.

EXAMPLE 12.6-2. Estimation of Interfacial Tension
Equilibrium data for the system water (A)–acetic acid (C)–methylisobutyl ketone (MIBK) (B)
are as follows in wt %, where the acetic acid concentration is dilute (P4):
Water-rich (A) phase MIBK-rich (B) phase
Water (A) Acid (B) MIBK (C) Water (A) Acid (C) MIBK (B)
98.45 0 1.55 2.12 0 97.88
95.46 2.85 1.7 2.80 1.87 95.33

Estimate the interfacial tension for the data point containing some acetic acid.

S olu t ion: The molecular weight for A is 18.02, for B is 100.16, and for C is 60.05. Converting
1.7 wt % (B) to mole fraction xBA in the (A)-rich layer,

Also, 2.85 wt % (C) in the (A)-rich layer becomes xCA = 0.00885. Similarly, 2.80 wt % (C)
becomes xAB = 0.1365, and 1.87 wt % (C) becomes xCB = 0.02736.

Substituting into Eq. (12.6-1),

For the binary liquid system, water (A)–MIBK (B), the calculated mole fractions are xBA =
0.002825 and xAB = 0.1074. Then using Eq. (12.6-1), σ = 11.49 dyn/cm.

12.6 E. Pe r for ate d -Plate  (S ie v e -Tr ay) Extr action Tow e r s

Perforated plates or sieve trays are also used for dispersion of liquid drops and coalescence on each tray,
as shown in Fig. 12.6-4. This is similar to the sieve trays described in Fig. 10.6-1a for distillation and
absorption. The downcomers carry the heavier continuous liquid phase from one tray to the next. The
light dispersed phase coalesces below the tray, jets up to the tray above, and then coalesces on the tray
above. Overflow weirs are not used on downcomers (S3).

Figure 12.6-4. Perforated-plate or sieve-tray extraction tower.
The holes in the tray are 0.32–0.64 cm in diameter, and the % of open tray area is 15–25% of the column
cross-sectional area. Tray spacings of 10–25 cm are used.

The following equation can be used to estimate the fractional tray efficiency Eo in a tray tower (P4):

Equation 12.6-2

where σ is interfacial tension in dyn/cm, T is tray spacing in ft, do is hole diameter in ft, and VD and VC
are superficial velocities in ft/s. For systems with high interfacial tensions, heights of transfer units are
relatively high and stage efficiencies low.

Some typical operating conditions in tray towers are given in Table 12.6-1. To scale-up towers from small
to larger sizes, the same sum of superficial velocities VC + VD should be used (S3). A throughput design
value of about 50% of flooding also should be used for all types of extraction towers.

EXAMPLE 12.6-3. Tray Efficiency for Perforated-Plate
Tower
Acetic acid is being extracted from water by the solvent methylisobutyl ketone in a perforated-
plate tower at 25°C. The flow rate of the continuous aqueous phase is 120 ft 3/h and that of the
dispersed solvent phase is 240 ft 3/h. The interfacial tension is 9.1 dyn/cm. The tray spacing is
1.0 ft and the hole size on the tray is 0.25 in. Estimate the fraction tray efficiency Eo.

S olu t ion: VD/VC = 240/120, σ = 9.1 dyn/cm, T = 1.0 ft, and do = 0.25/12 = 0.02083 ft.
Substituting into Eq. (12.6-2),
12.6 F. Pu lse d  Packe d  and  S ie v e -Tr ay Tow e r s

There are many types of towers that are mechanically agitated to increase the mass-transfer efficiency
and/or the throughput. An ordinary packed tower or one with special sieve plates can be pulsed by
applying a rapid reciprocating motion of relatively short amplitude to the liquid contents. A
reciprocating plunger pump, bellows pump, or high-pressure air pulse is externally connected to the
space containing the continuous fluid so that the entire contents of the tower move up or down.
Continuous inlet flows of continuous and dispersed phases enter and exit the tower.

1. Pu lsed  p a ck ed  t ow er s

Pulsing packed towers reduces the HETS considerably, by about a factor of 2 or so. Pulsing is also useful
in handling liquids with high interfacial tensions, up to 30–40 dyn/cm (W1). Typical values for HETS of
0.15–0.3 m are given in Table 12.6-1. Since pulsing is uniform across the cross section, scale-up of tower
size can be accomplished by using the same value of VD + VC (W1).

2. Pu lsed  siev e-t r a y  t ow er s

Typical amplitudes used are from 0.6 to 2.5 cm and frequencies from 100 to 250 cycles/min (P4). Typical
hole size is 0.32 cm diameter, with 20–25% free space on the tray and 5.1 cm (2 in.) tray spacing. The
trays occupy the entire cross section of the tower and there are no downspouts. During upward pulsing,
the light liquid is forced through the holes and droplets rise to the tray above. During downward pulsing,
the heavy liquid behaves in a similar manner. Typical operating values are given in Table 12.6-1. Pulsing
the tower markedly reduces the HETS.

12.6 G . M e chanically Agitate d  Extr action Tow e r s

There are many types of mechanically agitated towers, two of the most important of which are the
Scheibel tower shown in Fig. 12.6-5a and the Karr tower shown in Fig. 12.6-5b.

Figure 12.6-5. Mechanically agitated extraction towers: (a) Scheibel rotating-agitator tower, (b) Karr
reciprocating-plate tower.
1. S cheib el t ow er

In the Scheibel tower, a series of rotating turbine agitators form dispersions which coalesce in passing
through the knitted mesh. The mixture then passes through the outer settling zone. The tower thus
operates as a series of mixer–settler extraction units.

The tower operates with high efficiencies, as shown in Table 12.6-1. In scaling up from a total combined
flow rate Q1 for both phases in m3/s to Q2, the diameter D2 is approximately related to D1 by (L4, S2)

Equation 12.6-3

Also, in scaling up from diameter D1 to D2, the HETS varies as follows:

Equation 12.6-4

Equations for scale-up of the column internals are available (L4, S6).

2. K a r r  r ecip r oca t ing -p la t e t ow er


As shown in Fig. 12.6-5b for the Karr column, the perforated trays are moved up and down to increase
agitation and to pulse the liquids. This results in a more uniform drop-size distribution because the shear
forces are more uniform over the tower cross section (K4, P4).

Typical parameters are an amplitude of plate movement of 2.5 cm (1 in.), 100–150 strokes/min, and
plate spacing of 5–15 cm. Trays contain holes 1.4 cm in diameter and open space of 50–60% (W1). Scale-
up procedures for the Karr column are relatively accurate. In scaling up a small tower with diameter D1 to
a larger size D2, the total throughput per unit area (VC + VD), plate spacing, and amplitude are kept
constant. Then the HETS in m and the strokes per minute (SPM) are scaled up by (K4, P4)

Equation 12.6-5

Equation 12.6-6

Typical performance values are given in Table 12.6-1.
                             
                                                 
                                             
                                               
     

12.7. CONTINUOUS MULTISTAGE COUNTERCURRENT
EXTRACTION

12.7A. Intr od u ction

In Section 12.5 single-stage equilibrium contact was used to transfer solute A from one liquid to another
liquid phase. To transfer more solute, single-stage contact can be repeated by bringing the exit L1 stream
into contact with fresh solvent V2, as shown in Fig. 12.5-6. In this way a greater percentage removal of
solute A is obtained. However, this is wasteful of the solvent stream as well as giving a dilute product of
A in the outlet solvent extract streams. In order to use less solvent and to obtain a more concentrated exit
extract stream, countercurrent multistage contacting is often employed.

Figure 12.7-7. Extr action-tower flows: (a) process flow and material balance for countercurrent extr action


tower, (b) operating line for minimum solvent flow for tower and actual operating line.

[View full size image]

Many of the fundamental equations for countercurrent gas absorption and rectification are the same as or
similar to those used in countercurrent extraction. Because of the frequently high solubility of the two
liquid phases in each other, the equilibrium relationships in extraction are more complicated than in
absorption and distillation.
12.7B. C ontinu ou s M u ltistage  C ou nte r cu r r e nt Extr action

1. C ou nt er cu r r ent  p r ocess a nd  ov er a ll b a la nce

The process flow for this extraction process is the same as given previously in Fig. 10.3-2 and is shown in
Fig. 12.7-1. The feed stream containing the solute A to be extracted enters at one end of the process and
the solvent stream enters at the other end. The extract and raffinate streams flow countercurrently from
stage to stage, and the final products are the extract stream V1 leaving stage 1 and the raffinate stream
LN  leaving stage N.

Figure 12.7-1. Countercurrent-multistage-extraction-process flow diagram.

[View full size image]

Making an overall balance on all N stages,

Equation 12.7-1

where M represents total kg/h (lbm/h) and is a constant, L0 the inlet feed flow rate in kg/h, VN+1 the inlet
solvent flow rate in kg/h, V1 the exit extract stream, and LN  the exit raffinate stream. Making an overall
component balance on component C,

Equation 12.7-2

Combining Eqs. (12.7-1) and (12.7-2) and rearranging,

Equation 12.7-3

A similar balance on component A gives

Equation 12.7-4
Equations (12.7-3) and (12.7-4) can be used to calculate the coordinates of point M on the phase
diagram, which ties together the two entering streams L0 and VN+1 and the two exit streams V1 and LN .
Usually, the flows and compositions of L0 and VN+1 are known and the desired exit composition xAN  is
set. If we plot points L0, VN+1, and M as in Fig. 12.7-2, a straight line must connect these three points.
Then LN , M, and V1 must lie on one line. Moreover, LN  and V1 must also lie on the phase envelope, as
shown. These balances also hold for lbm and mass fraction, kg mol and mol fractions, and so on.

Figure 12.7-2. Use of the mixture point M for overall material balance in counter current solvent extraction.

EXAMPLE 12.7-1. Material Balance for Countercurrent
Stage Process
Pure solvent isopropyl ether at the rate of VN+1 = 600 kg/h is being used to extract an aqueous
solution of L0 = 200 kg/h containing 30 wt % acetic acid (A) by countercurrent multistage
extraction. The desired exit acetic acid concentration in the aqueous phase is 4%. Calculate the
compositions and amounts of the ether extract V1 and the aqueous raffinate LN . Use
equilibrium data from Appendix A.3.

S olu t ion: The given values are VN+1 = 600, y AN+1 = 0, y CN+1 = 1.0, L0 = 200, xA0 = 0.30, xB0


= 0.70, xC0 = 0, and xAN  = 0.04. In Fig. 12.7-3, VN+1 and L0 are plotted. Also, since LN  is on
the phase boundary, it can be plotted at xAN  = 0.04. For the mixture point M, substituting
into Eqs. (12.7-3) and (12.7-4),

Equation 12.7-3
Figure 12.7-3. Method to perform overall material balance for Example 12.7-1.

Equation 12.7-4

Using these coordinates, the point M is plotted in Fig. 12.7-3. We locate V1 by drawing a line
from LN  through M and extending it until it intersects the phase boundary. This gives y A1 =
0.08 and y C1 = 0.90. For LN  a value of xCN  = 0.017 is obtained. By substituting into Eqs.
(12.7-1) and (12.7-2) and solving, LN  = 136 kg/h and V1 = 664 kg/h.

2. S t a g e-t o-st a g e ca lcu la t ions for  cou nt er cu r r ent  ext r a ct ion

The next step after an overall balance has been made is to go stage by stage to determine the
concentrations at each stage and the total number of stages N needed to reach LN  in Fig. 12.7-1.

Making a total balance on stage 1,

Equation 12.7-5

Making a similar balance on stage n,
Equation 12.7-6

Rearranging Eq. (12.7-5) to obtain the difference Δ in flows,

Equation 12.7-7

This value of Δ in kg/h is constant, and for all stages,

Equation 12.7-8

This also holds for a balance on component A, B, or C:

Equation 12.7-9

Combining Eqs. (12.7-8) and (12.7-9) and solving for xΔ,

Equation 12.7-10

where xΔ is the x coordinate of point Δ.

Equations (12.7-7) and (12.7-8) can be written as

Equation 12.7-11

From Eq. (12.7-11), we see that L0 is on a line through Δ and V1, Ln  is on a line through Δ and Vn+1, and
so on. This means Δ is a point common to all streams passing each other, such as L0 and V1, Ln  and
Vn+1, LN  and VN+1, and so on. The coordinates for locating this Δ operating point are given for xCΔ and
xAΔ in Eq. (12.7-10). Since the end points VN+1, LN  or V1, and L0 are known, xΔ can be calculated and
point Δ located. Alternatively, the Δ point is located graphically in Fig. 12.7-4 as the intersection of lines
L0V1 and LN VN+1.
Figure 12.7-4. Operating point Δ and number of theoretical stages needed for countercurrent extraction.

In order to step off the number of stages using Eq. (12.7-11) we start at L0 and draw the line L0ΔΔ, which
locates V1 on the phase boundary. Next a tie line through V1 locates L1, which is in equilibrium with V1.
Then line L1ΔΔ is drawn giving V2. The tie line V2L2 is drawn. This stepwise procedure is repeated until
the desired raffinate composition LN  is reached. The number of stages N required to perform the
extraction is thus obtained.

EXAMPLE 12.7-2. Number of Stages in Countercurrent
Extraction
Pure isopropyl ether of 450 kg/h is being used to extract an aqueous solution of 150 kg/h with
30 wt % acetic acid (A) by countercurrent multistage extraction. The exit acid concentration in
the aqueous phase is 10 wt %. Calculate the number of stages required.

S olu t ion: The known values are VN+1 = 450, y AN+1 = 0, y CN+1 = 1.0, L0 = 150, xA0 = 0.30,


xB0 = 0.70, xC0 = 0, and xAN  = 0.10. The points VN+1, L0, and LN  are plotted in Fig. 12.7-5.
For the mixture point M, substituting into Eqs. (12.7-3) and (12.7-4), xCM = 0.75 and xAM =
0.075. The point M is plotted and V1 is located at the intersection of line LN M with the phase
boundary to give y A1 = 0.072 and y C1 = 0.895. (This construction is not shown. See Example
12.7-1 for construction of lines.)

Figure 12.7-5. Graphical solution for countercurrent extraction in Example 12.7-2.
The lines L0V1 and LN VN+1 are drawn and the intersection is the operating point ΔΔ as shown.
Alternatively, the coordinates of ΔΔ can be calculated from Eq. (12.7-10) to locate point ΔΔ.
Starting at L0 we draw line L0ΔΔ, which locates V1. Then a tie line through V1 locates L1 in
equilibrium with V1. (The tie-line data are obtained from an enlarged plot such as the bottom
of Fig. 12.5-3.) Line L1ΔΔ is next drawn locating V2. A tie line through V2 gives L2. A line L2ΔΔ
gives V3. A final tie line gives L3, which has gone beyond the desired LN . Hence, about 2.5
theoretical stages are needed.

3. M inimu m solv ent  r a t e

If a solvent rate VN+1 is selected at too low a value, a limiting case will be reached, with a line through ΔΔ
and a tie line being the same. Then an infinite number of stages will be needed to reach the desired
separation. The minimum amount of solvent has been reached. For actual operation a greater amount of
solvent must be used.

The procedure for obtaining this minimum is as follows. A tie line is drawn through point L0 (Fig. 12.7-4)
to intersect the extension of line LN VN+1. Other tie lines to the left of this tie line are drawn, including one
through LN  to intersect the line LN VN+1. The intersection of a tie line on line LN VN+1 which is nearest to
VN+1 represents the ΔΔmin  point for minimum solvent. The actual position of ΔΔ used must be closer to
VN+1 than Δmin  for a finite number of stages. This means that more solvent must be used. Usually, the tie
line through L0 represents the ΔΔmin .
12.7C . C ou nte r cu r r e nt-S tage  Extr action w ith Im m iscib le  Liq u id s

If the solvent stream VN+1 contains components A and C and the feed stream L0 contains A and B, and if
components B and C are relatively immiscible in each other, the stage calculations may be made more
easily. The solute A is relatively dilute and is being transferred from L0 to VN+1.

Referring to Fig. 12.7-1 and making an overall balance for A over the whole system and then over the first
n stages,

Equation 12.7-12

Equation 12.7-13

where L'= kg inert B/h, V' = kg inert C/h, y = mass fraction A in V stream, and x = mass fraction A in L
stream. This Eq. (12.7-13) is an operating-line equation whose slope ≅ L'/V'. If y and x are quite dilute,
the line will be straight when plotted on an x-y diagram.

The number of stages are stepped off as shown previously for cases of distillation and absorption, as
shown in Fig. 10.3-4.

If the equilibrium line is relatively dilute, then since the operating line is essentially straight, the
analytical Eqs. (10.3-21)–(10.3-26) given in Section 10.3D can be used to calculate the number of stages.

EXAMPLE 12.7-3. Extraction of Nicotine with Immiscible
Liquids.
An inlet water solution of 100 kg/h containing 0.010 wt fraction nicotine (A) in water is
stripped with a kerosene stream of 200 kg/h containing 0.0005 wt fraction nicotine in a
countercurrent-stage tower. The water and kerosene are essentially immiscible in each other. It
is desired to reduce the concentration of the exit water to 0.0010 wt fraction nicotine.
Determine the theoretical number of stages needed. The equilibrium data are as follows (C5),
with x the weight fraction of nicotine in the water solution and y in the kerosene:

x y x y

0.001010 0.000806 0.00746 0.00682

0.00246 0.001959 0.00988 0.00904


0.00500 0.00454 0.0202 0.0185

a.  Plot the equilibrium data and graphically determine the number of theoretical steps.

b.  Use the Kremser equation (10.3-21) and calculate the number of theoretical steps.
S olu t ion: The given values are L0 = 100 kg/h, x0 = 0.010, VN+1 = 200 kg/h, y N+1 = 0.0005,
xN  = 0.0010. The inert streams are

Making an overall balance on A using Eq. (12.7-12) and solving, y 1 = 0.00498. These points on the
operating line are plotted in Fig. 12.7-6.

Figure 12.7-6. Solution for extraction with immiscible liquids in Example 12.7-3.

Since the operating-line equation is for dilute solutions, a straight line is drawn. The equilibrium data are
plotted and the line is slightly curved.

For part (a), the number of stages are stepped off, giving N = 4.5 theoretical stages.

For part (b), to calculate the total flow rates LN  and V1, the following equations can be solved:
Also, L0 = 100 and VN+1 = 200 kg/h. To use Eq. (10.3-21) the slope of the equilibrium curve must be
calculated at the top and bottom of the tower, since the line is not straight. At the top on the equilibrium
curve, at the point y 1 = 0.00498, the tangent or slope at this point is determined to be m1 = 0.91. At the
bottom or dilute end, at xN  = 0.0010 on the equilibrium curve, the line is straight and m2 can be
calculated from the equilibrium data as m2 = 0.000806/0.001010 = 0.798. Then A1 = L/(mV) =
L0/(m1V1) = 100/(0.91 × 200.9) = 0.547. Also, A2 = LN /(m2VN+1) = 99.1/(0.798 × 200) = 0.621. The

average value of A =   = 0.583.

Substituting into Eq. (10.3-22) using m = m2 = 0.798,

N = 4.45 theoretical stages. This compares closely with the graphical-method result of 4.5 theoretical
stages.

12.7D. De sign of Tow e r s for  Extr action

1. Op er a t ing -line eq u a t ion for  r ela t iv ely  immiscib le liq u id s

In this case, in Fig. 12.7-7a the liquid feed stream L and the solvent stream V are relatively immiscible in
each other and solute A is relatively dilute in both streams. The outlet feed stream is commonly called the
raffinate and the outlet solvent stream the extract. For the countercurrent extraction of A from the feed
stream L to the solvent stream V, an overall material balance around the dashed-line box gives the
following operating line equation:

Equation 12.7-14

Figure 12.9-1. Several typical equilibrium diagrams: (a) case for vertical tie lines and y A =x A, (b) case where


y A ≠×x A for tie lines.
where L' = kg feed B/h, V' = kg solvent/h, y = mass fraction A in solvent V stream, and x = mass fraction
A in feed L stream.

This operating-line equation will be slightly curved when plotted on an x-y diagram as in Fig. 12.7-7b.
Note that units of mole fraction and molar flow rates can also be used. The number of theoretical steps
are stepped off as previously shown in Fig. 12.7-6. If the two liquid solvent and feed streams are
immiscible in each other, L' and V' are constant.

2. Limit ing  solv ent  flow s a nd  op t imu m L'/V' r a t ios

In an extraction process, the inlet feed flow L2 and its composition x2 are usually set. The exit
concentration x1 in the raffinate (L1 stream) is often set by the designer. The inlet concentration y 1 of the
solvent (V1 stream) is generally fixed by process requirements in regenerating the solvent for recycle back
to the tower. Hence, the amount of the entering solvent flow V1 or V' is open to choice.

In Fig. 12.7-7b, the concentrations x1, x2, and y 1 are set. When the operating line has a maximum slope

and touches the equilibrium line at point P, then the solvent flow is at a minimum at .   The value of
y 2 is at a maximum of y 2,max. As in absorption and stripping, the optimum flow rate is taken as 1.2–1.5

times  , with 1.5 normally used (S6). Note that if the equilibrium line is curved and highly concave
upward, then, for the minimum value , the operating line is tangent to the equilibrium line instead of
intersecting it. Then the optimum is taken as 1.2–1.5 times. .

3. Ana ly t ica l eq u a t ions for  nu mb er  of t r a y s

The analytical equation to calculate the number of theoretical trays N for extraction is the same as Eq.
(10.6-8) for stripping in gas–liquid separations and is given as

Equation 12.7-15

where A = L/mV. The value of A may vary in the tower if the operating and equilibrium lines are curved
somewhat. Referring to Fig. 12.7-7b, at the concentrated top of the tower, the slope m2 or tangent at
point y 2 on the equilibrium line is used. At the bottom or dilute end, the slope m1 at point x1 on the

equilibrium line is used. Then A1 = L1/m1V1, A2 = L2/m2 V2, and A =   Also, the dilute m1 is used
in Eq. (12.7-15). A useful equation is Eq. (12.7-16), which allows one to calculate the performance of an
existing tower when the number of theoretical steps N are known:

Equation 12.7-16

12.7E. De sign of Packe d  Tow e r s for  Extr action Using M ass-Tr ansfe r  C oe fficie nts

The use of mass-transfer coefficients in extraction is similar to their use in stripping in absorption. The
equations for dilute solutions and essentially immiscible solvents using overall coefficients are
essentially identical to those for stripping with dilute solutions as given previously in Section 10.6G as
Eq. (10.6-46) and (10.6-47). For extraction,

Equation 12.7-17

Equation 12.7-18
If both the operating and equilibrium lines are straight and dilute, the integral in Eq. (12.7-17) can be
integrated to give

Equation 12.7-19

where

Equation 12.7-20

In terms of the V phase,

Equation 12.7-21

where (y − y*)M is defined in Eq. (10.6-28). The value of the overall number of transfer units NOL can also
be determined using Eq. (10.6-53) as

Equation 12.7-22

EXAMPLE 12.7­4  Extraction of Acetone from Water with
Trichloroethane in a Tower
An inlet water solution of 800 kg/h containing 12.0 wt % acetone is extracted with the solvent
trichloroethane containing 0.5 wt % acetone in a countercurrent tray tower at 25°C. The
solvents water and trichloroethane are essentially immiscible in each other up to a
concentration of acetone in water of 27 wt %. The exit concentration in the water (raffinate)
stream is set at 1.0 wt % acetone. The equilibrium data are as follows (T3), where x is the
weight fraction of acetone in the water solution and y in the trichloroethane solution:

x y x y

0.0120 0.0196 0.0833 0.1304

0.0294 0.0476 0.1081 0.1666


0.0462 0.0741 0.1316 0.2000
0.0571 0.0909  

a.  Determine the minimum solvent rate needed.

b.  Using 1.3 times the minimum rate, graphically determine the number of theoretical
steps needed.

c.  Calculate the number of steps using the analytical equation.

d.  Using a packed tower, the height of a transfer unit HOL is estimated to be 1.2 m.
Calculate the number of transfer units NOL and the tower height.

S olu t ion: For part (a), the given values are L2 = 800 kg/h, x2 = 0.12, x1 = 0.01, y 1 = 0.005.


The inlet stream is

The equilibrium data are plotted in Fig. 12.7-8, and the line is curved somewhat. The
operating line for minimum solvent flow is plotted from point x1, y 1 to point P, where x2 = 0.12
on the equilibrium line and y 2,max = 0.184.

Figure 12.7-8. Operating and equilibrium line for Example 12.7-4.

[View full size image]

Rewriting Eq. (12.7-14) for an overall balance, and substituting the known values,
Solving, V' =   = 403.2 kg solvent/h. Setting x = 0.07 in Eq. (12.7-14) and solving, y =
0.1062. Repeating this for several other x values, these points on the operating line are plotted
in Fig. 12.7-8. This operating line for minimum solvent flow (dashed line) is slightly curved
and does not intersect or become tangent to the equilibrium line at any point other than P.

For part (b), V' = 1.3  = 1.3(403.2) = 524.2 kg solvent/h. Substituting into the operating-
line Eq. (12.7-14) and solving for y 2,

Then, y 2 = 0.1486. As before, calculating several points on the operating line, which is curved,
for x = 0.04, y = 0.0453; for x = 0.08, y = 0.0977. Plotting these points shows a curved
operating line. Stepping off the trays, a total of 7.4 steps are obtained.

For part (c), the total flows are first calculated as

The value of m2 is the slope or tangent at point y 2 on the equilibrium line, which gives m2 =
1.49. The value of m1 at point x1 at the dilute end on the equilibrium line is, from the first set of
equilibrium data points, equal to y/x = 0.0196/0.0120 = 1.633 = m1. Then

Using Eq. (12.7-15),
Then, N = 7.46 theoretical steps. This agrees closely with the graphical value of 7.4.

For part (d), Eq. (12.7-19) will not be used, because the operating and equilibrium lines are
slightly curved. Using Eq. (12.7-22),

Solving, NOL = 8.09 transfer units. Then, z = HOLNOL = 1.2(8.09) = 9.71 m.
                             
                                                 
                                             
                                               
     

12.8. INTRODUCTION AND EQUIPMENT FOR LIQUID–SOLID
LEACHING

12.8A. Le aching Pr oce sse s

1. Int r od u ct ion

Many biological and inorganic and organic substances occur in a mixture of different components in a
solid. In order to separate the desired solute constituent or remove an undesirable solute component
from the solid phase, the solid is contacted with a liquid phase. The two phases are in intimate contact
and the solute or solutes can diffuse from the solid to the liquid phase, resulting in a separation of the
components originally in the solid. This separation process is called liquid–solid leaching or simply
leaching. The term extraction is also used to describe this separation process, although it also refers to
liquid–liquid extraction. In leaching, when an undesirable component is removed from a solid with
water, the process is called washing.

2. Lea chi ng  p r ocesses for  b iolog ica l su b st a nces

In the biological and food processing industries, many products are separated from their original natural
structure by liquid–solid leaching. An important process, for example, is the leaching of sugar from
sugar beets with hot water. In the production of vegetable oils, organic solvents such as hexane, acetone,
and ether are used to extract the oil from peanuts, soybeans, flax seeds, castor beans, sunflower seeds,
cotton seeds, tung meal, and halibut livers. In the pharmaceutical industry, many different
pharmaceutical products are obtained by leaching plant roots, leaves, and stems. For the production of
soluble “instant” coffee, ground roasted coffee is leached with fresh water. Soluble tea is produced by
water leaching of tea leaves. Tannin is removed from tree barks by leaching with water.

3. Lea chi ng  p r ocesses for  inor g a nic a nd  or g a nic ma t er ia ls

Leaching processes are used extensively in the metals processing industries. The useful metals usually
occur in mixtures with very large amounts of undesirable constituents, and leaching is used to remove
the metals as soluble salts. Copper salts are dissolved or leached from ground ores containing other
minerals by sulfuric acid or ammoniacal solutions. Cobalt and nickel salts are leached from their ores by
sulfuric acid–ammonia–oxygen mixtures. Gold is leached from its ore using an aqueous sodium cyanide
solution. Sodium hydroxide is leached from a slurry of calcium carbonate and sodium hydroxide
prepared by reacting Na2CO3 with Ca(OH)2.

12.8B. Pr e p ar ation of S olid s for  Le aching

1. Inor g a nic a nd  or g a nic ma t er ia ls

The method of preparation of the solid depends to a large extent upon the proportion of the soluble
constituent present, its distribution throughout the original solid, the nature of the solid—that is,
whether it is composed of plant cells or whether the soluble material is completely surrounded by a
matrix of insoluble matter—and the original particle size.

If the soluble material is surrounded by a matrix of insoluble matter, the solvent must diffuse inside to
contact and dissolve the soluble material and then diffuse out. This occurs in many hydrometallurgical
processes where metal salts are leached from mineral ores. In these cases crushing and grinding of the
ores is used to increase the rate of leaching, since the soluble portions are made more accessible to the
solvent. If the soluble substance is in solid solution in the solid or is widely distributed throughout the
whole solid, the solvent leaching action may form small channels. The passage of additional solvent is
then made easier, and grinding to very small sizes may not be needed. Grinding of the particles is not
necessary if the soluble material is dissolved in solution adhering to the solid. Then simple washing can
be used, as in washing of chemical precipitates.

2. Anima l a nd  v eg et a b le ma t er ia ls

Biological materials are cellular in structure and the soluble constituents are generally found inside the
cells. The rate of leaching may be comparatively slow because the cell walls provide another resistance to
diffusion. However, to grind the biological material sufficiently small to expose the contents of individual
cells is impractical. Sugar beets are cut into thin, wedge-shaped slices for leaching so that the distance
required for the water solvent to diffuse in order to reach individual cells is reduced. The cells of the sugar
beet are kept essentially intact so that sugar will diffuse through the semipermeable cell walls, while the
undesirable albuminous and colloidal components cannot pass through the walls.

For the leaching of pharmaceutical products from leaves, stems, and roots, drying of the material before
extraction helps rupture the cell walls. Thus, the solvent can directly dissolve the solute. The cell walls of
soybeans and many vegetable seeds are largely ruptured when the original materials are reduced in size
to about 0.1 mm to 0.5 mm by rolling or flaking. Cells are smaller in size, but the walls are ruptured and
the vegetable oil is easily accessible to the solvent.

12.8C . R ate s of Le aching

1. Int r od u ct ion a nd  g ener a l st ep s

In the leaching of soluble materials from inside a particle by means of a solvent, the following general
steps can occur in the overall process. The solvent must be transferred from the bulk solvent solution to
the surface of the solid. Next, the solvent must penetrate or diffuse into the solid. The solute dissolves
into the solvent. The solute then diffuses through the solid solvent mixture to the surface of the particle.
Finally, the solute is transferred to the bulk solution. The many different phenomena encountered make
it virtually impracticable if not impossible to apply any one theory to the leaching action.

In general, the rate of transfer of the solvent from the bulk solution to the solid surface is quite rapid,
while the rate of transfer of the solvent into the solid may be somewhat rapid or slow. These are not, in
many cases, the rate-limiting steps in the overall leaching process. This solvent transfer usually occurs
initially, when the particles are first contacted with the solvent. The dissolving of the solute into the
solvent inside the solid may be a simple physical dissolution process or an actual chemical reaction that
frees the solute for dissolution. Our knowledge of the dissolution process is limited and the mechanism
may be different for each solid (K1).

The rate of diffusion of the solute through the solid and solvent to the surface of the solid is often the
controlling resistance in the overall leaching process and may depend on a number of different factors. If
the solid is made up of an inert porous solid structure, with the solute and solvent in the pores in the
solid, the diffusion through the porous solid can be described by an effective diffusivity. The void fraction
and tortuosity are needed. This is described in Section 6.5C for diffusion in porous solids.
In biological or natural substances, additional complexity occurs because of the cells present. In the
leaching of thin sugar beet slices, about one-fifth of the cells are ruptured in the slicing of the beets. The
leaching of the sugar is then similar to a washing process (Y1). In the remaining cells, sugar must diffuse
out through the cell walls. The net result of the two transfer processes does not follow the simple
diffusion law with a constant effective diffusivity.

With soybeans, whole beans cannot be leached effectively. The rolling and flaking of the soybeans
ruptures cell walls so that the solvent can more easily penetrate by capillary action. The rate of diffusion
of the soybean oil solute from the soybean flakes does not permit simple interpretation. A method for
designing large-scale extractors involves using small-scale laboratory experiments (O2) with flakes.

The resistance to mass transfer of the solute from the solid surface to the bulk solvent is in general quite
small compared to the resistance to diffusion within the solid (O1) itself. This has been found for leaching
soybeans, where the degree of agitation of the external solvent has no appreciable effect on the extraction
rate (O3, Y1).

2. R a t e of lea ching  w hen d issolv ing  a  solid

When a material is being dissolved from the solid to the solvent solution, however, the rate of mass
transfer from the solid surface to the liquid is the controlling factor. There is essentially no resistance in
the solid phase if it is a pure material. The equation for this can be derived as follows for a batch system.
The following can also be used for the case when diffusion in the solid is very rapid compared to diffusion
from the particle.

The rate of mass transfer of solute A being dissolved to the solution of volume V m3 is

Equation 12.8-1

where   is kg mol of A dissolving to the solution/s. A is surface area of particles in m2, kL is a mass-
transfer coefficient in m/s, cAS is the saturation solubility of the solid solute A in the solution in kg

mol/m3, and cA is the concentration of A in the solution at time t sec in kg mol/m3. By a material
balance, the rate of accumulation of A in the solution is equal to Eq. (12.8-1) times the area A:

Equation 12.8-2

Integrating from t = 0 and cA = cA0 to t = t and cA = cA,

Equation 12.8-3
Equation 12.8-4

The solution approaches a saturated condition exponentially. Often the interfacial area A will increase
during the extraction if the external surface becomes very irregular. If the soluble material forms a high
proportion of the total solid, disintegration of the particles may occur. If the solid is completely
dissolving, the interfacial area changes markedly. Also, the mass-transfer coefficient may then change.

If the particles are very small, the mass-transfer coefficient to the particle in an agitated system can be
predicted by using equations given in Section 7.4. For larger particles, which are usually present in
leaching, equations for predicting the mass-transfer coefficient kL in agitated mixing vessels are given in
Section 7.4 and reference (B1).

3. R a t e of lea ching  w hen d iffu sion in solid  cont r ols

In the case where unsteady-state diffusion in the solid is the controlling resistance in the leaching of the
solute by an external solvent, the following approximations can be used. If the average diffusivity DAeff of
solute A is approximately constant, then for extraction in a batch process, unsteady-state mass-transfer
equations can be used, as discussed in Section 7.1. If the particle is approximately spherical, Fig. 5.3-13
can be used.

EXAMPLE 12.8-1. Prediction of Time for Batch Leaching
Particles having an average diameter of approximately 2.0 mm are leached in a batch-type
apparatus with a large volume of solvent. The concentration of the solute A in the solvent is
kept approximately constant. A time of 3.11 h is needed to leach 80% of the available solute
from the solid. Assuming that diffusion in the solid is controlling and the effective diffusivity
is constant, calculate the time of leaching if the particle size is reduced to 1.5 mm.

S olu t ion: For 80% extraction, the fraction unextracted Es is 0.20. Using Fig. 5.3-13 for a

sphere, for Es = 0.20, a value of DAeff t/a 2 = 0.112 is obtained, where DAeff is the effective

diffusivity in mm2/s, t is time in s, and a is radius in mm. For the same fraction Es, the value

of DAeff t/a 2 is constant for a different size. Hence,

Equation 12.8-5
where t 2 is time for leaching with a particle size a 2. Substituting into Eq. (12.8-5),

4 . M et hod s of op er a t ion in lea ching

There are a number of general methods of operation in the leaching of solids. The operations can be
carried out under batch or unsteady-state conditions as well as under continuous or steady-state
conditions. Both continuous and stagewise types of equipment are used in steady or unsteady-state
operation.

In unsteady-state leaching, a method commonly used in the mineral industries is in-place leaching,
where the solvent is allowed to percolate through the actual ore body. In other cases the leach liquor is
pumped over a pile of crushed ore and collected at the ground level as it drains from the heap. Copper is
leached by sulfuric acid solutions from sulfide ores in this manner.

Crushed solids are often leached by percolation through stationary solid beds in a vessel with a
perforated bottom to permit drainage of the solvent. The solids should not be too fine, or a high
resistance to flow will be encountered. Sometimes a number of tanks are used in series, called an
extraction battery, and fresh solvent is fed to the solid that is most nearly extracted. The tanks can be
open tanks or closed tanks called diffusers. The solvent flows through the tanks in series, being
withdrawn from the freshly charged tank. This simulates a continuous countercurrent stage operation.
As a tank is completely leached, a fresh charge is added to the tank at the other end. Multiple piping is
used so that tanks do not have to be moved for countercurrent operation. This is often called the Shanks
system. It is used widely in leaching sodium nitrate from ore, recovering tannins from barks and woods,
in the mineral industries, in the sugar industry, and in other processes.

In some processes the crushed solid particles are moved continuously by bucket-type conveyors or a
screw conveyor. The solvent flows countercurrent to the moving bed.

Finely ground solids may be leached in agitated vessels or in thickeners. The process can be unsteady-
state batch or the vessels can be arranged in a series to obtain a countercurrent stage process.

12.8D. Typ e s of Eq u ip m e nt for  Le aching

1. Fixed -b ed  lea ching

Fixed-bed leaching is used in the beet sugar industry and is also used for the extraction of tanning
extracts from tanbark, for the extraction of pharmaceuticals from barks and seeds, and in other
processes. In Fig. 12.8-1 a typical sugar beet diffuser or extractor is shown. The cover is removable so that
sugar beet slices called cossettes can be dumped into the bed. Heated water at 344 K (71°C) to 350 K
(77°C) flows into the bed to leach out the sugar. The leached sugar solution flows out the bottom onto the
next tank in series. Countercurrent operation is used in the Shanks system. The top and bottom covers
are removable so that the leached beets can be removed and a fresh charge added. About 95% of the sugar
in the beets is leached to yield an outlet solution from the system of about 12 wt %.

Figure 12.8-1. Typical fixed-bed apparatus for sugar beet leaching.
2. M ov ing -b ed  lea ching

There are a number of devices for stagewise countercurrent leaching where the bed or stage moves instead
of being stationary. These are used widely in extracting oil from vegetable seeds such as cottonseeds,
peanuts, and soybeans. The seeds are usually dehulled first, sometimes precooked, often partially dried,
and rolled or flaked. Sometimes preliminary removal of oil is accomplished by expression. The solvents
are usually petroleum products, such as hexane. The final solvent–vegetable solution, called miscella,
may contain some finely divided solids.

In Fig. 12.8-2a an enclosed moving-bed bucket elevator device is shown. This is called the Bollman
extractor. Dry flakes or solids are added at the upper right side to a perforated basket or bucket. As the
buckets on the right side descend, they are leached by a dilute solution of oil in solvent called half
miscella. This liquid percolates downward through the moving buckets and is collected at the bottom as
the strong solution or full miscella. The buckets moving upward on the left are leached countercurrently
by fresh solvent sprayed on the top bucket. The wet flakes are dumped as shown and removed
continuously.

The Hildebrandt extractor in Fig. 12.8-2b consists of three screw conveyors arranged in a U shape. The
solids are charged at the top right, conveyed downward, across the bottom, and then up the other leg.
The solvent flows countercurrently.

3. Ag it a t ed  solid  lea ching

When the solid can be ground fine to about 200 mesh (0.074 mm), it can be kept in suspension by small
amounts of agitation. Continuous countercurrent leaching can be accomplished by placing a number of
agitators in series, with settling tanks or thickeners between each agitator.

Sometimes the thickeners themselves are used as combination contactor-agitators and settlers, as shown
in Fig. 12.8-3. In this countercurrent-stage system, fresh solvent enters the first stage thickener as
shown. The clear, settled liquid leaves and flows from stage to stage. The feed solids enter the last stage,
where they are contacted with solvent from the previous stage and then enter the settler. The slowly
rotating rake moves the solids to the bottom discharge. The solids together with some liquid are pumped
as a slurry to the next tank. If the contact is insufficient, a mixer can be installed between the settlers.

Figure 12.8-3. Countercurrent leaching using thickeners.
[View full size image]

Figure 12.8-2. Equipment for moving-bed leaching: (a) Bollman bucket-type extractor, (b) Hildebrandt screw-
conveyor extractor.

[View full size image]
                             
                                                 
                                             
                                               
     

12.9. EQUILIBRIUM RELATIONS AND SINGLE­STAGE LEACHING

12.9 A. Eq u ilib r iu m  R e lations in Le aching

1. Int r od u ct ion

To analyze single-stage and countercurrent-stage leaching, an operating-line equation or material-
balance relation and the equilibrium relations between the two streams are needed, as in liquid–liquid
extraction. It is assumed that the solute-free solid is insoluble in the solvent. In leaching, assuming there
is sufficient solvent present so that all the solute in the entering solid can be dissolved into the liquid,
equilibrium is reached when the solute is dissolved. Hence, all the solute is completely dissolved in the
first stage. There usually is sufficient time for this to occur in the first stage.

It is also assumed that there is no adsorption of the solute by the solid in the leaching. This means that
the solution in the liquid phase leaving a stage is the same as the solution that remains with the solid
matrix in the settled slurry leaving the stage. In the settler in a stage it is not possible or feasible to
separate all the liquid from the solid. Hence, the settled solid leaving a stage always contains some liquid
in which dissolved solute is present. This solid–liquid stream is called the underflow or slurry stream.
Consequently, the concentration of oil or solute in the liquid or overflow stream is equal to the
concentration of solute in the liquid solution accompanying the slurry or underflow stream. Hence, on an
x-y plot the equilibrium line is on the 45° line.

The amount of solution retained with the solids in the settling portion of each stage may depend upon
the viscosity and density of the liquid in which the solid is suspended. This, in turn, depends upon the
concentration of the solute in the solution. Hence, experimental data showing the variation of the
amount and composition of solution retained in the solids as a function of the solute composition must
be obtained. These data should be obtained under conditions of concentrations, time, and temperature
similar to those in the process for which the stage calculations are to be made.

2. Eq u ilib r iu m d ia g r a ms for  lea chi ng

The equilibrium data can be plotted on the rectangular diagram as wt fraction for the three components:
solute (A), inert or leached solid (B), and solvent (C). The two phases are the overflow (liquid) phase and
the underflow (slurry) phase. This method is discussed elsewhere (B2). Another convenient method of
plotting the equilibrium data will be used, instead, which is similar to the method discussed in the
enthalpy–concentration plots in Section 11.6.

The concentration of inert or insoluble solid B in the solution mixture or the slurry mixture can be
expressed in kg (lbm) units:

Equation 12.9-1
There will be a value of N for the overflow where N = 0, and for the underflow N will have different values,
depending on the solute concentration in the liquid. The compositions of solute A in the liquid will be
expressed as wt fractions:

Equation 12.9-2

Equation 12.9-3

where xA is the wt fraction of solute A in the overflow liquid and y A is the wt fraction of A on a solid-B-free
basis in the liquid associated with the slurry or underflow. For the entering solid feed to be leached, N is
kg inert solid/kg solute A and y A = 1.0. For pure entering solvent N = 0 and xA = 0.

In Fig. 12.9-1a a typical equilibrium diagram is shown, where solute A is infinitely soluble in solvent C,
which would occur, for example, in the system soybean oil (A)–soybean inert solid meal (B)–hexane
solvent (C). The upper curve of N versus y A for the slurry underflow represents the separated solid under
experimental conditions similar to the actual stage process. The bottom line of N versus xA, where N = 0
on the axis, represents the overflow liquid composition where all the solid has been removed. In some
cases small amounts of solid may remain in the overflow. The tie lines are vertical, and on a y-x diagram,
the equilibrium line is y A = xA on the 45° line. In Fig. 12.9-1b the tie lines are not vertical, which can
result from insufficient contact time, so that all the solute is not dissolved; adsorption of solute A on the
solid; or the solute being soluble in the solid B.

Figure 12.9-2. Process flow and material balance for single-stage leaching: (a) process flow, (b) material
balance.

If the underflow line of N versus y is straight and horizontal, the amount of liquid associated with the
solid in the slurry is constant for all concentrations. This would mean that the underflow liquid rate is
constant throughout the various stages as well as the overflow stream. This is a special case which is
sometimes approximated in practice.

12.9 B. S ingle -S tage  Le aching

In Fig. 12.9-2a a single-stage leaching process is shown where V is kg/h (lbm/h) of overflow solution with
composition xA and L is kg/h of liquid in the slurry solution with composition y A based on a given flow
rate B kg/h of dry, solute-free solid. The material-balance equations are almost identical to Eqs. (12.5-
12)–(12.5-14) for single-stage liquid–liquid extraction and are as follows for a total solution balance
(solute A + solvent C), a component balance on A, and a solids balance on B, respectively:

Equation 12.9-4

Equation 12.9-5

Equation 12.9-6

Figure 12.11-3. Types of crystallizers: (a) circulating-liquid evaporator-crystallizer, (b) circulating-magma
vacuum crystallizer.

[View full size image]

where M is the total flow rate in kg A + C/h and xAM and NM are the coordinates of this point M. A
balance on C is not needed, since xA + xC = 1.0 and y A + y C = 1.0. As shown before, L1MV1 must lie on a
straight line and L0MV2 must also lie on a straight line. This is shown in Fig. 12.9-2b. Also, L1 and V1
must lie on the vertical tie line. The point M is the intersection of the two lines. If L0 entering is the fresh
solid feed to be leached with no solvent C present, it will be located above the N-versus-y line in Fig. 12.9-
2b.

EXAMPLE 12.9-1. Single-Stage Leaching of Flaked
Soybeans
In a single-stage leaching of soybean oil from flaked soybeans with hexane, 100 kg of soybeans
containing 20 wt % oil is leached with 100 kg of fresh hexane solvent. The value of N for the
slurry underflow is essentially constant at 1.5 kg insoluble solid/kg solution retained.
Calculate the amounts and compositions of the overflow V1 and the underflow slurry L1
leaving the stage.

S olu t ion: The process flow diagram is the same as given in Fig. 12.9-2a. The known process
variables are as follows: for the entering solvent flow, V2 = 100 kg, xA2 = 0, xC2 = 1.0; for the
entering slurry stream, B = 100(1.0 − 0.2) = 80 kg insoluble solid, L0 = 100(1.0 − 0.8) = 20 kg
A, N0 = 80/20 = 4.0 kg solid/kg solution, y A0 = 1.0.

To calculate the location of M, substituting into Eqs. (12.9-4), (12.9-5), and (12.9-6) and
solving,

Hence, xAM = 0.167.

The point M is plotted in Fig. 12.9-3 along with V2 and L0. The vertical tie line is drawn
locating L1 and V1 in equilibrium with each other. Then N1 = 1.5, y A1 = 0.167, xA1 = 0.167.
Substituting into Eqs. (12.9-4) and (12.9-6) and solving or using the lever-arm rule, L1 = 53.3
kg and V1 = 66.7 kg.

Figure 12.9-3. Graphical solution of single-stage leaching for Example 12.9-1.
                             
                                                 
                                             
                                               
     

12.10. COUNTERCURRENT MULTISTAGE LEACHING

12.10A. Intr od u ction and  Op e r ating Line  for  C ou nte r cu r r e nt Le aching

A process flow diagram for countercurrent multistage leaching is shown in Fig. 12.10-1 and is similar to
Fig. 12.7-1 for liquid–liquid extraction. The ideal stages are numbered in the direction of the solids or
underflow stream. The solvent (C)–solute (A) phase or V phase is the liquid phase that overflows
continuously from stage to stage countercurrent to the solid phase, dissolving solute as it moves along.
The slurry phase L composed of inert solids (B) and a liquid phase of A and C is the continuous
underflow from each stage. Note that the composition of the V phase is denoted by x and the composition
of the L phase by y, which is the reverse of that for liquid–liquid extraction.

Figure 12.10-1. Process flow for countercurrent multistage leaching.

[View full size image]

It is assumed that solid B is insoluble and is not lost in the liquid V phase. The flow rate of the solids is
constant throughout the cascade of stages. As in single-stage leaching, V is kg/h (lbm/h) of overflow
solution and L is kg/h of liquid solution in the slurry retained by the solid.

In order to derive the operating-line equation, an overall balance and a component balance on solute A is
made over the first n stages:

Equation 12.10-1

Equation 12.10-2

Solving for xn+1 and eliminating Vn+1,

Equation 12.10-3
The operating-line equation (12.10-3), when plotted on an x-y plot, passes through the terminal points
x1, y 0 and xN+1, y N .

In the leaching process, if the viscosity and density of the solution change appreciably with the solute (A)
concentration, the solids from the lower-numbered stages where solute concentrations are high may
retain more liquid solution than the solids from the higher-numbered stages, where the solute
concentration is dilute. Then Ln , the liquid retained in the solids underflow, will vary, and the slope of
Eq. (12.10-3) will vary from stage to stage. This condition of variable underflow will be considered first.
The overflow will also vary. If the amount of solution Ln  retained by the solid is constant and
independent of concentration, then constant underflow occurs. This simplifies somewhat the stage-to-
stage calculations. This case will be considered later.

12.10B. Var iab le  Und e r flow  in C ou nte r cu r r e nt M u ltistage  Le aching

The methods in this section are very similar to those used in Section 12.7B for countercurrent solvent
extraction, where the L and V flow rates varied from stage to stage. Making an overall total solution
(solute A + solvent C) balance on the process shown in Fig. 12.10-1,

Equation 12.10-4

where M is the total mixture flow rate in kg A + C/h. Next, making a component balance on A,

Equation 12.10-5

Making a total solids balance on B,

Equation 12.10-6

where NM and xAM are the coordinates of point M shown in Fig. 12.10-2, which is the operating diagram
for the process. As demonstrated previously, L0MVN+1 must lie on a straight line and V1MLN  must also
lie on a straight line. Usually the flows and compositions of L0 and VN+1 are known and the desired exit
concentration y AN  is set. Then the coordinates NM and xAM can be calculated from Eqs. (12.10-4)–(12.10-
6) and point M plotted. Then LN , M, and V1 must lie on one line, as shown in Fig. 12.10-2.

Figure 12.10-2. Number of stages for multistage countercurrent leaching.
In order to go stage by stage on Fig. 12.10-2, we must derive the operating-point equation. Making a total
balance on stage 1 and then on stage n,

Equation 12.10-7

Equation 12.10-8

Rearranging Eq. (12.10-7) for the difference flows Δ in kg/h,

Equation 12.10-9

This value Δ is constant and also holds for Eq. (12.10-8) rearranged and for all stages:

Equation 12.10-10
This can also be written for a balance on solute A to give

Equation 12.10-11

where xAΔ is the x coordinate of the operating point Δ. A balance made on solids gives

Equation 12.10-12

where NΔ is the N coordinate of the operating point Δ.

As shown in Section 12.7B, Δ is the operating point. This point Δ is located graphically in Fig. 12.10-2 as
the intersection of lines L0V1 and LN VN+1. From Eq. (12.10-10) we see that V1 is on a line between L0 and
Δ, V2 is on a line between L1 and Δ, Vn+1 is on a line between Ln  and Δ, and so on.

To graphically determine the number of stages, we start at L0 and draw line L0Δ to locate V1. A tie line
through V1 locates L1. Line L1Δ is drawn given V2. A tie line gives L2. This is continued until the desired
LN  is reached. In Fig. 12.10-2, about 3.5 stages are required.

EXAMPLE 12.10-1. Countercurrent Leaching of Oil from
Meal
A continuous countercurrent multistage system is to be used to leach oil from meal by benzene
solvent (B3). The process is to treat 2000 kg/h of inert solid meal (B) containing 800 kg oil (A)
and also 50 kg benzene (C). The inlet flow per hour of fresh solvent mixture contains 1310 kg
benzene and 20 kg oil. The leached solids are to contain 120 kg oil. Settling experiments
similar to those in the actual extractor show that the solution retained depends upon the
concentration of oil in the solution. The data (B3) are tabulated below as N kg inert solid B/kg
solution and y A kg oil A/kg solution:

N yA N yA

2.00 0 1.82 0.4

1.98 0.1 1.75 0.5


1.94 0.2 1.68 0.6

1.89 0.3 1.61 0.7

Calculate the amounts and concentrations of the stream leaving the process and the number of
stages required.

S olu t ion: The underflow data from the table are plotted in Fig. 12.10-3 as N versus y A. For the


inlet solution with the untreated solid, L0 = 800 + 50 = 850 kg/h, y A0 = 800/(800 + 50) =
0.941, B = 2000 kg/h, N0 = 2000/(800 + 50) = 2.36. For the inlet leaching solvent, VN+1 =
1310 + 20 = 1330 kg/h and xAN+1 = 20/1330 = 0.015. The points VN+1 and L0 are plotted.

Figure 12.10-3. Graphical construction for number of stages for Example 12.10-1.

The point LN  lies on the N-versus-y A line in Fig. 12.10-3. Also for this point, the ratio NN /y AN


= (kg solid/kg solution)/(kg oil/kg solution) = kg solid/kg oil = 2000/120 = 16.67. Hence, a
dashed line through the origin at y A = 0 and N = 0 is plotted with a slope of 16.67 and
intersects the N-versus-y A line at LN . The coordinates of LN  at this intersection are NN  = 1.95
kg solid/kg solution and y AN  = 0.118 kg oil/kg solution.

Making an overall balance by substituting into Eq. (12.10-4) to determine point M,

Substituting into Eq. (12.10-5) and solving,

Substituting into Eq. (12.10-6) and solving,
The point M is plotted with the coordinates xAM = 0.376 and NM = 0.918 in Fig. 12.10-3. The
line VN+1ML0 is drawn, as is line LN M, which intersects the abscissa at point V1 where xA1 =
0.600.

The amounts of streams V1 and LN  are calculated by substituting into Eqs. (12.10-4) and
(12.10-5), and solving simultaneously:

Hence, LN  = 1016 kg solution/h in the outlet underflow stream and V1 = 1164 kg solution/h in
the exit overflow stream. Alternatively, the amounts could have been calculated using the
lever-arm rule.

The operating point Δ is obtained as the intersection of lines L0V1 and LN VN+1 in Fig. 12.10-3.
Its coordinates can also be calculated from Eqs. (12.10-11) and (12.10-12). The stages are
stepped off as shown. The fourth stage for L4 is slightly past the desired LN . Hence, about 3.9
stages are required.

12.10C . C onstant Und e r flow  in C ou nte r cu r r e nt M u ltistage  Le aching

In this case the liquid Ln  retained in the underflow solids is constant from stage to stage. This means
that a plot of N versus y A is a horizontal straight line and N is constant. Then the operating-line equation
(12.10-3) is a straight line when plotted as y A versus xA. The equilibrium line can also be plotted on the
same diagram. In many cases the equilibrium line may also be straight, with y A = xA. Special treatment
must be given the first stage, however, as L0 is generally not equal to Ln , since it contains little or no
solvent. A separate material and equilibrium balance is made on stage 1 to obtain L1 and V2 (see Fig.
12.10-1). Then the straight operating line can be used and the McCabe–Thiele method used to step off the
number of stages.

Since this procedure for constant underflow requires almost as many calculations as the general case for
variable underflow, the general procedure can be used for constant underflow by simply using a
horizontal line of N versus y A in Fig. 12.10-2 and stepping off the stages with the Δ point.
                             
                                                 
                                             
                                               
     

12.11. INTRODUCTION AND EQUIPMENT FOR CRYSTALLIZATION

12.11A. C r ystalliza tion and  Typ e s of C r ystals

1. Int r od u ct ion

Separation processes for gas–liquid and liquid–liquid systems have been treated in this and previous
chapters. Also, the separation process of leaching was discussed for a solid–liquid system.
Crystallization is another solid–liquid separation process, in which mass transfer of a solute from the
liquid solution to a pure solid crystalline phase occurs. An important example is in the production of
sucrose from sugar beet, where the sucrose is crystallized out from an aqueous solution.

Crystallization is a process where solid particles are formed from a homogeneous phase. This process can
occur in the freezing of water to form ice, in the formation of snow particles from a vapor, in the formation
of solid particles from a liquid melt, or in the formation of solid crystals from a liquid solution. The last
process mentioned, crystallization from a solution, is the most important one commercially and will be
treated in the present discussion. In crystallization the solution is concentrated and usually cooled until
the solute concentration becomes greater than its solubility at that temperature. Then the solute comes
out of the solution, forming crystals of approximately pure solute.

In commercial crystallization not only are the yield and purity of the crystals important but also the sizes
and shapes of the crystals. It is often desirable that crystals be uniform in size. Size uniformity is
desirable to minimize caking in the package, for ease of pouring, for ease in washing and filtering, and for
uniform behavior when used. Sometimes large crystals are requested by the purchaser, even though
smaller crystals are just as useful. Also, crystals of a certain shape are sometimes required, such as
needles rather than cubes.

2. Ty p es of cr y st a l g eomet r y

A crystal can be defined as a solid composed of atoms, ions, or molecules which are arranged in an
orderly and repetitive manner. It is a highly organized type of matter. The atoms, ions, or molecules are
located in three-dimensional arrays or space lattices. The interatomic distances between these imaginary
planes or space lattices in a crystal are measured by X-ray diffraction, as are the angles between these
planes. The pattern or arrangement of these space lattices is repeated in all directions.

Crystals appear as polyhedrons having flat faces and sharp corners. The relative sizes of the faces and
edges of different crystals of the same material may differ greatly. However, the angles between the
corresponding faces of all crystals of the same material are equal and are characteristic of that particular
material. Therefore, crystals are classified on the basis of these interfacial angles.

There are seven classes of crystals, depending upon the arrangement of the axes to which the angles are
referred:

1.  Cubic system. Three equal axes at right angles to each other.

2.  Tetragonal system. Three axes at right angles to each other, one axis longer than the other two.
3.  Orthorhombic system. Three axes at right angles to each other, all of different lengths.

4.  Hexagonal system. Three equal axes in one plane at 60° to each other, and a fourth axis at right
angles to this plane and not necessarily the same length.

5.  Monoclinic system. Three unequal axes, two at right angles in a plane and a third at some angle to
this plane.

6.  Triclinic system. Three unequal axes at unequal angles to each other and not 30, 60, or 90°.

7.  Trigonal system. Three equal and equally inclined axes.

The relative development of different types of faces of a crystal may differ depending on the solute
crystallizing. Sodium chloride crystallizes from aqueous solutions with cubic faces only. But if sodium
chloride crystallizes from an aqueous solution with a given slight impurity present, the crystals will have
octahedral faces. Both types of crystals, however, are in the cubic system. The crystallization in overall
shapes of plates or needles has no relation to the type of crystal system and usually depends upon the
process conditions under which the crystals are grown.

12.11B. Eq u ilib r iu m  S olu b ility in C r ystallization

In crystallization equilibrium is attained when the solution or mother liquor is saturated. This is
represented by a solubility curve. Solubility is dependent mainly upon temperature. Pressure has a
negligible effect on solubility. Solubility data are given in the form of curves where solubilities in some
convenient units are plotted versus temperature. Tables of solubilities are given in many chemical
handbooks (P1). Solubility curves for some typical salts in water were given in Fig. 8.1-1. In general, the
solubilities of most salts increase slightly or markedly with increasing temperature.

A very common type of curve is shown in Fig. 8.1-1 for KNO3, where the solubility increases markedly
with temperature and there are no hydrates. Over the whole range of temperatures, the solid phase is
KNO3. The solubility of NaCl is marked by its small change with temperature. In solubility plots the
solubility data are ordinarily given as parts by weight of anhydrous material per 100 parts by weight of
total solvent (i.e., water in many cases).

In Fig. 12.11-1 the solubility curve is shown for sodium thiosulfate, Na2S2O3. The solubility increases
rapidly with temperature, but there are definite breaks in the curve which indicate different hydrates. The
stable phase up to 48.2°C is the pentahydrate Na2S2O3 5H2O. This means that at concentrations above
the solubility line (up to 48.2°C), the solid crystals formed are Na2S2O3 5H2O. At concentrations below
the solubility line, only a solution exists. From 48.2 to about 65°C, the stable phase is Na2S2O3 2H2O. A
half-hydrate is present between 65 to 70°C, and the anhydrous salt is the stable phase above 70°C.

Figure 12.11-1. Solubility of sodium thiosulfate, Na2 S2 O3 , in water.
12.11C . Y ie ld s and  He at and  M ate r ial Balance s in C r ystallization

1. Y ield s a nd  ma t er ia l b a la nces in cr y st a lliza t ion

In most of the industrial crystallization processes, the solution (mother liquor) and the solid crystals are
in contact for enough time to reach equilibrium. Hence, the mother liquor is saturated at the final
temperature of the process, and the final concentration of the solute in the solution can be obtained from
the solubility curve. The yield of crystals from a crystallization process can then be calculated knowing
the initial concentration of solute, the final temperature, and the solubility at this temperature.

In some instances in commercial crystallization, the rate of crystal growth may be quite slow, due to a
very viscous solution or a small surface of crystals exposed to the solution. Hence, some supersaturation
may still exist, giving a lower yield of crystals than predicted.

In making the material balances, the calculations are straightforward when the solute crystals are
anhydrous. Simple water and solute material balances are made. When the crystals are hydrated, some
of the water in the solution is removed with the crystals as a hydrate.

EXAMPLE 12.11-1. Yield of a Crystallization Process
A salt solution weighing 10000 kg with 30 wt % Na2CO3 is cooled to 293 K (20°C). The salt
crystallizes as the decahydrate. What will be the yield of Na2CO3 ∊· 10H2O crystals if the
solubility is 21.5 kg anhydrous Na2CO3/100 kg of total water? Do this for the following cases:

a.  Assume that no water is evaporated.

b.  Assume that 3% of the total weight of the solution is lost by evaporation of water in
cooling.

S olu t ion: The molecular weights are 106.0 for Na2CO3, 180.2 for 10H2O, and 286.2 for
Na2CO3 10H2O. The process flow diagram is shown in Fig. 12.11-2, with W being kg H2O
evaporated, S kg solution (mother liquor), and C kg crystals of Na2CO3 10H2O. Making a
material balance around the dashed-line box for water for part (a), where W = 0,

Equation 12.11-1
Figure 12.11-2. Process flow for crystallization in Example 12.11-1.

where (180.2)/(286.2) is wt fraction of water in the crystals. Making a balance for Na2CO3,

Equation 12.11-2

Solving the two equations simultaneously, C = 6370 kg of Na2CO3 · 10H2O crystals and S =
3630 kg solution.

For part (b), W = 0.03(10 000) = 300 kg H2O. Equation (12.11-1) becomes

Equation 12.11-3

Equation (12.11-2) does not change, since no salt is in the W stream. Solving Eqs. (12.11-2) and
(12.11-3) simultaneously, C = 6630 kg of Na2CO3 · 10H2O crystals and S = 3070 kg solution.

2. Hea t  effect s a nd  hea t  b a la nces in cr y st a lliza t ion

When a compound whose solubility increases as temperature increases dissolves, there is an absorption
of heat, called the heat of solution. An evolution of heat occurs when a compound dissolves whose
solubility decreases as temperature increases. For compounds dissolving whose solubility does not
change with temperature, there is no heat evolution on dissolution. Most data on heats of solution are
given as the change in enthalpy in kJ/kg mol (kcal/g mol) of solute occurring with the dissolution of 1 kg
mol of the solid in a large amount of solvent at essentially infinite dilution.

In crystallization the opposite of dissolution occurs. At equilibrium the heat of crystallization is equal to
the negative of the heat of solution at the same concentration in solution. If the heat of dilution from
saturation in the solution to infinite dilution is small, this can be neglected, and the negative of the heat
of solution at infinite dilution can be used for the heat of crystallization. With many materials this heat
of dilution is small compared with the heat of solution, and this approximation is reasonably accurate.
Heat-of-solution data are available in several references (P1, N1).

Probably the most satisfactory method for calculating heat effects during a crystallization process is to
use the enthalpy–concentration chart for the solution and the various solid phases which are present for
the system. However, only a few such charts are available, including the following systems: calcium
chloride–water (H1), magnesium sulfate–water (P2), and ferrous sulfate–water (K2). When such a chart
is available, the following procedure is used. The enthalpy H1 of the entering solution at the initial
temperature is read off the chart, where H1 is kJ (btu) for the total feed. The enthalpy H2 of the final
mixture of crystals and mother liquor at the final temperature is also read off the chart. If some
evaporation occurs, the enthalpy Hv  of the water vapor is obtained from the steam tables. Then the total
heat absorbed q in kJ is

Equation 12.11-4

If q is positive, heat must be added to the system. If it is negative, heat is evolved or given off.

EXAMPLE 12.11-2. Heat Balance in Crystallization
A feed solution of 2268 kg at 327.6 K (54.4°C) containing 48.2 kg MgSO4/100 kg total water is
cooled to 293.2 K (20°C), where MgSO4 · 7H2O crystals are removed. The solubility of the salt
is 35.5 kg MgSO4/100 kg total water (P1). The average heat capacity of the feed solution can be

assumed as 2.93 kJ/kg · K (H1). The heat of solution at 291.2 K (18°C) is −13.31 × 103 kJ/kg
mol MgSO4 · 7H2O (P1). Calculate the yield of crystals and make a heat balance to determine
the total heat absorbed, q, assuming that no water is vaporized.

S olu t ion: Making a water balance and a balance for MgSO4 using equations similar to (12.11-
1) and (12.11-2) in Example 12.11-1, C = 616.9 kg MgSO4 · 7H2O crystals and S = 1651.1 kg
solution.

To make a heat balance, a datum of 293.2 K (20°C) will be used. The molecular weight of
MgSO4 · 7H2O is 246.49. The enthalpy of the feed is H1:

The heat of solution is −(13.31 × 103)/246.49 = −54.0 kJ/kg crystals. Then the heat of
crystallization is −(−54.0) = +54.0 kJ/kg crystals, or 54.0(616.9) = 33 312 kJ. This assumes
that the value at 291.2 K is the same as at 293.2 K. The total heat absorbed, q, is
Since q is negative, heat is given off and must be removed.

12.11D. Eq u ip m e nt for  C r ystallization

1. Int r od u ct ion a nd  cla ssifica t ion of cr y st a llizer s

Crystallizers may be classified according to whether they are batch or continuous in operation. Batch
operation is done for certain special applications. Continuous operation of crystallizers is generally
preferred.

Crystallization cannot occur without supersaturation. A main function of any crystallizer is to cause a
supersaturated solution to form. Crystallizing equipment can be classified according to the methods
used to bring about supersaturation as follows: (1) supersaturation produced by cooling the solution
with negligible evaporation—tank and batch-type crystallizers; (2) supersaturation produced by
evaporation of the solvent with little or no cooling—evaporator–crystallizers and crystallizing
evaporators; (3) supersaturation by combined cooling and evaporation in an adiabatic evaporator—
vacuum crystallizers.

In crystallizers producing supersaturation by cooling, the substances must have a solubility curve that
decreases markedly with temperature. This occurs for many substances, and this method is commonly
used. When the solubility curve changes little with temperature, as for common salt, evaporation of the
solvent to produce supersaturation is often used. Sometimes evaporation with some cooling may be
used. In the method of cooling adiabatically in a vacuum, a hot solution is introduced into a vacuum,
where the solvent flashes or evaporates and the solution is cooled adiabatically. This method for
producing supersaturation is the most important one for large-scale production.

In another method of classification of crystallizers, the equipment is classified according to the method of
suspending the growing product crystals. Examples are crystallizers where the suspension is agitated in
a tank, is circulated by a heat exchanger, or is circulated in a scraped surface exchanger.

An important difference between many commercial crystallizers is the manner in which the
supersaturated liquid contacts the growing crystals. In one method, called the circulating magma
method, the entire magma of crystals and supersaturated liquid is circulated through both the
supersaturation and crystallization steps without separating the solid from the liquid into two streams.
Crystallization and supersaturation are occurring together in the presence of the crystals. In the second
method, called the circulating liquid method, a separate stream of supersaturated liquid is passed
through a fluidized bed of crystals, where the crystals grow and new ones form by nucleation. Then the
saturated liquid is passed through an evaporating or cooling region to produce supersaturation again for
recycling.

2. Ta nk  cr y st a llizer s

In tank crystallization, which is an old method still used in some specialized cases, hot saturated
solutions are allowed to cool in open tanks. After a period of time the mother liquor is drained and the
crystals removed. Nucleation and the size of crystals are difficult to control. Crystals contain
considerable amounts of occluded mother liquor. Labor costs are very high. In some cases the tank is
cooled by coils or a jacket and an agitator used to improve the heat-transfer rate. However, crystals often
build up on these surfaces. This type of crystallizer has limited application; it is sometimes used to
produce certain fine chemicals and pharmaceutical products.

3. S cr a p ed  su r fa ce cr y st a llizer s

One type of scraped surface crystallizer is the Swenson– Walker crystallizer, which consists of an open
trough 0.6 m wide with a semicircular bottom having a cooling jacket outside. A slow-speed spiral
agitator rotates and suspends the growing crystals on turning. The blades pass close to the wall and
break off any deposits of crystals on the cooled wall. The product generally has a somewhat wide crystal-
size distribution.

In the double-pipe scraped surface crystallizer, cooling water passes in the annular space. An internal
agitator is fitted with spring-loaded scrapers that wipe the wall and provide good heat-transfer
coefficients. This type is called a votator and is used in crystallizing ice cream and plasticizing
margarine. A sketch is given in Fig. 4.13-2.

4 . C ir cu la t ing -liq u id  ev a p or a t or –cr y st a llizer

In a combination evaporator–crystallizer, shown in Fig. 12.11-3a, supersaturation is generated by
evaporation. The circulating liquid is drawn by the screw pump down inside the tube side of the
condensing steam heater. The heated liquid then flows into the vapor space, where flash evaporation
occurs, giving some supersaturation. The vapor leaving is condensed. The supersaturated liquid flows
down the downflow tube and then up through the bed of fluidized and agitated crystals, which are
growing in size. The leaving saturated liquid then goes back as a recycle stream to the heater, where it is
joined by the entering feed. The larger crystals settle out and a slurry of crystals and mother liquor is
withdrawn as product. This type is also called the Oslo crystallizer.

5. C ir cu la t ing -ma g ma  v a cu u m cr y st a llizer

In the circulating-magma vacuum-type crystallizer shown in Fig. 12.11-3b, the magma or suspension of
crystals is circulated out of the main body through a circulating pipe by a screw pump. The magma flows
through a heater, where its temperature is raised 2–6 K. The heated liquor then mixes with body slurry
and boiling occurs at the liquid surface. This causes supersaturation in the swirling liquid near the
surface, which results in deposits on the swirling suspended crystals until they leave again via the
circulating pipe. The vapors leave through the top. A steam-jet ejector provides the vacuum.
                             
                                                 
                                             
                                               
     

12.12. CRYSTALLIZATION THEORY

12.12A. Intr od u ction

When crystallization occurs in a homogeneous mixture, a new solid phase is created. An understanding
of the mechanisms by which crystals form and then grow is helpful in designing and operating
crystallizers. Much experimental and theoretical work has been done to help understand crystallization.

The overall process of crystallization from a supersaturated solution is considered to consist of the basic
steps of nucleus formation or nucleation and of crystal growth. If the solution is free of all solid particles,
whether foreign or of the crystallizing substance, then nucleus formation must first occur, before crystal
growth starts. New nuclei may continue to form while the nuclei present are growing. The driving force
for the nucleation step as well as the growth step is supersaturation. These two steps do not occur in a
saturated or undersaturated solution.

12.12B. Nu cle ation The or ie s

1. S olu b ilit y  a nd  cr y st a l size

In a solution at a given temperature, the thermodynamic difference between small and large particles or
crystals is that the small particle has a significant amount of surface energy per unit mass, whereas the
large particle does not. As a result, the solubility of a small crystal, of less than micrometer size, is greater
than that of a larger-size crystal.

The ordinary solubility applies only to moderately large crystals. Hence, in a supersaturated solution a
small crystal can be in equilibrium. If a larger crystal is also present, the larger crystal will grow and the
smaller crystal will dissolve. This effect of particle size is an important factor in nucleation.

2. Homog eneou s nu clea t ion

As a result of rapid random fluctuations of molecules in a homogeneous solution, the molecules may
come together and associate into a cluster. This loose aggregate may quickly disappear. However, if the
supersaturation is large enough, then enough particles may associate to form a nucleus which can grow
and become oriented into a fixed lattice to form a crystal. The number of particles needed to form a stable
nucleus ranges up to a few hundred. In solutions with high supersaturation and no agitation,
homogeneous nucleation may be important.

3. C ont a ct  nu clea t ion

This is due to two types of contact nucleation. In the first type, the formation of new nuclei by contact
nucleation is due to interference of the contacting agent (walls of a container or agitator blades) with
clusters of solute molecules becoming organized into the existing crystals and by actual breakage of
microscopic growths on the surface of the growing crystals. In the second type, the formation of new
nuclei occurs in collisions between crystals. The intensity of agitation is an important factor in contact
nucleation.
This phenomenon of contact nucleation has been isolated and studied experimentally (B9, C4) and a
correlation has been developed. In practice, experimental data from an actual crystallizer are required for
design.

4 . Nu clea t ion in commer cia l cr y st a llizer s

In commercial crystallizers, supersaturation is low and agitation is used to keep the crystals suspended.
At low supersaturation the crystal growth rate is at the optimum for more-uniform crystals. The
predominant mechanism is contact nucleation. Homogeneous nucleation is largely absent because of the
agitation and low supersaturation.

12.12C . R ate  of C r ystal G r ow th and  ΔL Law

1. R a t e of cr y st a l g r ow t h a nd  g r ow t h coefficient s

The rate of growth of a crystal face is the distance moved per unit time in a direction that is perpendicular
to the face. Crystal growth is a layer-by-layer process, and since growth can occur only at the outer face of
the crystal, the solute material must be transported to that face from the bulk of the solution. The solute
molecules reach the face by diffusion through the liquid phase. The usual mass-transfer coefficient ky
applies in this case. At the surface the resistance to integration of the molecules into the space lattice at
the face must be considered. This reaction at the surface occurs at a finite rate, and the overall process
consists of two resistances in series. The solution must be supersaturated for the diffusion and interfacial
steps to proceed.

The equation for mass transfer of solute A from the bulk solution of supersaturation concentration y A,

mole fraction of A, to the surface where the concentration is,  , is

Equation 12.12-1

where ky  is the mass-transfer coefficient in kg mol/sm2mol frac,   is rate in kg mol A/s, and Ai is area

in m2 of surface i. Assuming that the rate of reaction at the crystal surface is also dependent on the
concentration difference,

Equation 12.12-2

where ks is a surface-reaction coefficient in kg mol/s · m2 · mol frac and y Ae is the saturation
concentration. Combining Eqs. (12.12-1) and (12.12-2),
Equation 12.12-3

where K is the overall transfer coefficient.

The mass-transfer coefficient ky  can be predicted by methods given in Section 7.4 for convective mass-
transfer coefficients. When the mass-transfer coefficient ky  is very large, the surface reaction is controlling
and 1/ky  is negligible. Conversely, when the mass-transfer coefficient is very small, diffusional resistance
is controlling. Surface-reaction coefficients and overall transfer coefficients have been measured and
reported for a number of systems (B4, H2, P3, V1). Much of the information in the literature is not
directly applicable, because the conditions of measurement differ greatly from those in a commercial
crystallizer. Also, the velocities and the level of supersaturation in a system are difficult to determine,
and vary with position of the circulating magma in the crystallizer.

2. The ΔL la w  of cr y st a l g r ow t h.

McCabe (M1) has shown that all crystals that are geometrically similar and of the same material in the
same solution grow at the same rate. Growth is measured as the increase in length ΔL, in mm, in linear
dimension of one crystal. This increase in length is for geometrically corresponding distances on all
crystals. This increase is independent of the initial size of the initial crystals, provided that all the
crystals are subject to the same environmental conditions. This law follows from Eq. (12.12-3), where the
overall transfer coefficient is the same for each face of all crystals.

Mathematically, this can be written

Equation 12.12-4

where Δt is time in h and growth rate G is a constant in mm/h. Hence, if D1 is the linear dimension of a
given crystal at time t 1 and D2 at time t 2,

Equation 12.12-5

The total growth (D2 − D1) or ΔL is the same for all crystals.

The ΔL law fails in cases where the crystals are given any different treatment based on size. It has been
found to hold for many materials, particularly when the crystals are under 50 mesh in size (0.3 mm).
Even though this law is not applicable in all cases, it is reasonably accurate in many situations.

12.12D. Par ticle -S ize  Distr ib u tion of C r ystals

An important factor in the design of crystallization equipment is the expected particle-size distribution of
the crystals obtained. Usually, the dried crystals are screened to determine the particle sizes. The percent
retained on different-sized screens is recorded. The screens or sieves used are the Tyler standard screens,
whose sieve or clear openings in mm are given in Appendix A.5-3.

The data are plotted as particle diameter (sieve opening in screen) in mm versus the cumulative percent
retained at that size on arithmetic probability paper. Data for urea particles from a typical crystallizer
(B5) are shown in Fig. 12.12-1. Many types of such data will show an approximate straight line for a large
portion of the plot.

Figure 12.12-1. Typical particle-size distribution from a crystal-lizer. [From R. C. Bennett and M. Van Buren,
Chem. Eng. Progr. Symp., 65(95), 46 (1969).]

A common parameter used to characterize the size distribution is the coefficient of variation, CV, as a
percent:

Equation 12.12-6

where PD16% is the particle diameter at 16 percent retained. By giving the coefficient of variation and
mean particle diameter, a description of the particle-size distribution is obtained if the line is
approximately straight between 90 and 10%. For a product removed from a mixed-suspension
crystallizer, the CV value is about 50% (R1). In a mixed-suspension system, the crystallizer is at steady
state and contains a well-mixed-suspension magma with no product classification and no solids
entering with the feed.

12.12E. M od e l for  M ixe d  S u sp e nsion–M ixe d  Pr od u ct R e m ov al C r ystallize r

1. Int r od u ct ion a nd  mod el a ssu mp t ions

This model will be derived for a mixed suspension–mixed product removal (MSMPR) crystallizer, which
is by far the most important type of crystallizer in use in industry today. Conditions assumed are as
follows: steady state, suspension completely mixed, no product classification, uniform concentration, no
crystals in feed, and the ΔL law of crystal growth applies. All continuous crystallizers have mixing by an
agitator or by pump around. In ideal mixing, the effluent composition is the same as in the vessel. This is
similar to a CSTR continuous-stirred tank reactor.

2. C r y st a l p op u la t ion-d ensit y  fu nct ion n

To analyze data from a crystallizer, an overall theory must consider combining the effects of nucleation
rate, growth rate, and material balance. Randolph and Larson (R1, R2, R3) derived such a model. They
plotted the total cumulative number of crystals N per unit volume of suspension (usually 1 L) of size L
and smaller versus this size L, as in Fig. 12.12-2. The slope dN/dL of this line is defined as the crystal
population density n:

Equation 12.12-7

Figure 12.12-2. Determination of population density n of crystals.

where n is the number of crystals/(L · mm). This characterizes the nuclear growth rate of this crystallizer.
For this model a relation between population density n and size L is desired.

This population density is obtained experimentally by screen analysis of the total crystal content of a
given volume, such as 1.0 L of magma suspension. Each sieve fraction by weight is obtained by collection
between two closely spaced and adjacent screens. Then, Lav  = (L1 + L2)/2, where L1 and L2 are the
openings in mm in the two adjacent screens. Also, ΔL = (L1 − L2), where L1 is the size opening of the
upper screen. Then the volume of a particle νp is

Equation 12.12-8
where νp is mm3/particle and a is a constant shape factor. Knowing the total weight of the crystals in

this fraction, the density ρ in g/mm3, and the weight of each crystal, which is ρνp, the total number of
crystals ΔN is obtained for the size range ΔL.

Then, rewriting Eq. (12.12-7) for this ΔL size,

Equation 12.12-9

This method permits the calculation of n for each fraction collected in the screen analysis with an average
size of Lav  mm.

3. Pop u la t ion ma t er ia l b a la nce

To make a population material balance, in Δt time, Δn ΔL crystals are withdrawn. Since the effluent
composition in the outflow of Q L/h is the same as that in the crystallizer, then the ratio (Δn ΔL)/(n ΔL),
or fraction of particles withdrawn during Δt time, is the same as the volume ratio Q Δt withdrawn
divided by the total volume V of the crystallizer. Hence,

Equation 12.12-10

During this time period Δt, the growth ΔL of a crystal is

Equation 12.12-11

where G is growth rate in mm/h. Combining Eqs. (12.12-10) and (12.12-11),

Equation 12.12-12

Letting ΔL → 0, Δn → 0, and integrating,

Equation 12.12-13
Equation 12.12-14

where n0 is population of nuclei when L = 0, n is population when the size is L, and V/Q is τ the total
retention or holdup time in h in the crystallizer. A plot of Eq. (12.12-14) of lnn versus L is a straight line
with intercept n0 and slope −1/Gτ. If the line is not straight, this could be an indication of the violation
of the ΔL law. These calculations are well suited for being done with a computer spreadsheet.

4 . Av er a g e p a r t icle size a nd  nu clea t ion r a t e

Further derivation of the population approach results in the equation for the average size La  in mm of the
mass distribution:

Equation 12.12-15

Here, 50% of the mass of the product is smaller or larger in size than this value. Also, the predominant
particle size is given as

Equation 12.12-16

This predominant particle size means more of the mass is in this differential size interval than in any
other size interval.

Another relation can be obtained from this model, which relates the nucleation rate B0 to the value of the
zero-size particle population density n0 and the growth rate G. For the condition L → 0, the limit of
dN/dt (nucleation rate) can be written as

Equation 12.12-17

However, when L → 0, the slope dL/dt = G, the slope dN/dL = n0, and B0 = dN/dt. Hence,

Equation 12.12-18

where B0 is nucleation rate in number of nuclei/h · L.
5. Pr ed ict ion of cu mu la t iv e w eig ht  fr a ct ion ob t a ined

The population equation can be used to perform a reverse calculation when only values of G and τ are
known. The following equation has been derived from the population density function (L4):

Equation 12.12-19

where x = L/Gτ, and (1 − Wf) is the cumulative wt fraction at opening L mm, which is in the same form of
results as from a screen analysis.

6 . Use of p op u la t ion-mod el a p p r oa ch for  p r ocess d esig n

The data for experimental crystal growth rate G and nucleation rate B0 obtained by means of the
population material balance are for one given set of conditions in the crystallizer. Then additional
experiments can be conducted to determine the effect of residence time τ (production rate) and, possibly,
pump-around rate (mixing) on B0 and G. This is done until the desired distribution Wf from Eq. (12.12-
19) is achieved. Or, in some cases, the goal may be for a desired dominant size Ld to be obtained. In many
cases, as the residence time τ is increased, the experimental growth rate G decreases. Additional useful
references are (B6, C2, C4, L5, M2, P1, R4, S2).

EXAMPLE 12.12­1  Growth and Nucleation Rates in
MSMPR Crystallizer
Calculate the population density and nucleation growth rates for crystal samples of urea from
a screen analysis. The slurry density (g of crystals) is 450 g/liter, the crystal shape factor a is
1.00, the crystal density ρ is 1.335 g/cm3, and the residence time τ is 3.38 h. The screen
analysis from reference (B5) is as follows:

Mesh Wt % Mesh Wt %

−14, +20 4.4 −48, +65 15.5


−20, +28 14.4 −65, +100 7.4
−28, +35 24.2 −100 2.5

−35, +48 31.6    

S olu t ion: The data above are tabulated in Table 12.12-1 using data from Appendix A.5-3. The
value of L is the screen opening. For the 14–20 mesh portion, Lav  = (1.168 + 0.833)/2 = 1.001

mm and ΔL = 1.168 − 0.833 = 0.335 mm. For Lav  = 1.001 mm, using Eq. (12.12-8), νp = 

= 1.00(1.001)3 = 1.003 mm3/particle. The density ρ = 1.335 g/cm3 = 1.335 × 10−3 g/mm3 and
the mass/particle = ρνp = 1.335 × 10−3 (1.003) = 1.339 × 10−3 g. The total mass of crystals =
(450 g/L)(0.044 wt frac).

Table 12.12-1. Data and Calculations for Example 12.12-1
Mesh L (mm) Mesh L (mm) Lav  (mm) ΔL (mm) ln n wt %

14 1.168 20 0.833 1.001 0.335 10.695 4.4

20 0.833 28 0.589 0.711 0.244 13.224 14.4


28 0.589 35 0.417 0.503 0.172 15.131 24.2
35 0.417 48 0.295 0.356 0.122 16.778 31.6
48 0.295 65 0.208 0.252 0.087 17.441 15.5

65 0.208 100 0.147 0.178 0.061 18.099 7.4

Using Eq. (12.12-9) to calculate n for the 14–20 mesh size range,

Then ln n = ln 4.414 × 104 = 10.695. For the 20–28 mesh size range, Lav  = 0.711/mm, and ΔL
= 0.244. Then,

Then ln n = 13.224. Other values are calculated in a similar manner using a computer
spreadsheet and are given in Table 12.12-1.

The ln n is plotted versus L in Fig. 12.12-3. The equation of this line is Eq. (12.12-14), where the
slope is −9.12 and the intercept = 19.79:

Figure 12.12-3. Plot of population density n versus length for Example 12.12-1.
The slope −9.12 = −1/Gτ = −1/(G)(3.38). Hence, G = 0.03244 mm/h. The intercept ln n0 =
19.79. Hence, n0 = 3.933 × 108. From Eq. (12.12-18), the nucleation rate B0 is

B0 = Gn0 = 0.03244(3.933 ×108) = 1.26 × 107  nuclei/h · L

The average size is, from Eq. (12.12-15), La  = 3.67Gτ = 3.67(0.03244)(3.38) = 0.402 mm. The
predominant size, from Eq. (12.12-16), is Ld = 3.00Gτ = 3.00(0.03244)(3.38) = 0.329 mm.
                             
                                                 
                                             
                                               
     

PROBLEMS
12.1-1.
Eq u ilib r iu m Isot he r m for  G lu cose Ad sor p t ion. Equilibrium isotherm data for adsorption
of glucose from an aqueous solution to activated alumina are as follows (H3):

C (g/cm3 ) 0.0040 0.0087 0.019 0.027 0.094 0.195

q (g solute/g alumina) 0.026 0.053 0.075 0.082 0.123 0.129

Determine the isotherm that fits the data and give the constants of the equation using the given
units.
A1:Ans. Langmuir isotherm, q = 0.145c/(0.0174 + c)
12.2-1.
Ba t ch Ad sor p t ion for  Phe nol S olu t ion. A wastewater solution having a volume of 2.5 m3
contains 0.25 kg phenol/m3 of solution. This solution is mixed thoroughly in a batch process
with 3.0 kg of granular activated carbon until equilibrium is reached. Use the isotherm from
Example 12.2-1 and calculate the final equilibrium values and the percent phenol extracted.
12.3-1.
S ca le-Up  of La b or a t or y  Ad sor p t ion-C olu mn Da t a . Using the break-point time and other
results from Example 12.3-1, do as follows:

a.  The break-point time for a new column is to be 8.5 h. Calculate the new total length of the
column required, column diameter, and the fraction of total capacity used up to the break
point. The flow rate is to remain constant at 754 cm3/s.

b.  Use the same conditions as in part (a), but the flow rate is to be increased to 2000 cm3/s.

A3:Ans. (a) HT = 27.2 cm, 0.849 fraction; (b) D = 6.52 cm
12.3-2.
Dr y ing  of Nit r og en a nd  S ca le-Up  of C olu mn. Using molecular sieves, water vapor was
removed from nitrogen gas in a packed bed (C3) at 28.3°C. The column height was 0.268 m,
with the bulk density of the solid bed being equal to 712.8 kg/m3. The initial water concentration
in the solid was 0.01 kg water/kg solid and the mass velocity of the nitrogen gas was 4052 kg/m2
· h. The initial water concentration in the gas was co = 926 × 10−6 kg water/kg nitrogen. The
breakthrough data are as follows:

t (h) 0 9 9.2 9.6 10 10.4

c (kg H2 O/kg N2  × 106 ) <0.6 0.6 2.6 21 91 235

t (h) 10.8 11.25 11.5 12.0 12.5 12.8

c (kg H2 O/kg N2  × 106 ) 418 630 717 855 906 926


A value of c/co = 0.02 is desired at the break point. Do as follows:

a.  Determine the break-point time, the fraction of total capacity used up to the break point,
the length of the unused bed, and the saturation loading capacity of the solid.

b.  For a proposed column length HT = 0.40 m, calculate the break-point time and fraction of
total capacity used.

A4 :Ans. (a) t b = 9.58 h, fraction used = 0.878
12.4 -1.
S ca le-Up  of Ion-Excha ng e C olu mn. An ion-exchange process using a resin to remove copper
ions from aqueous solution is conducted in a 1.0-in.-diameter column 1.2 ft high. The flow rate is
1.5 gph and the break point occurred at 7.0 min. Integrating the breakthrough curve gives a ratio
of usable capacity to total capacity of 0.60. Design a new tower that will be 3.0 ft high and
operate at 4.5 gph. Calculate the new tower size and break-point time.
A5:Ans. t b = 24.5 min, D = 1.732 in.
12.4 -2.
Heig ht  of Tow er  in Ion Excha ng e. In a given run using a flow rate of 0.2 m3/h in an ion-
exchange tower with a column height of 0.40 m, the break point occurred at 8.0 min. The ratio of
usable capacity to total equilibrium capacity is 0.65. What is the height of a similar column
operating for 13.0 min to the break point at the same flow rate?
12.4 -3.
Ion Excha ng e of C op p er  in C olu mn. An ion-exchange column containing 99.3 g of
amberlite ion-exchange resin was used to remove Cu2+ from a solution where co = 0.18 M CuSO4.

The tower height = 30.5 cm and the diameter = 2.59 cm. The flow rate was 1.37 cm3 solution/s to
the tower. The breakthrough data are shown below:

t (s) 420 480 510 540 600 660

c (g mol Cu/L) 0 0.0033 0.0075 0.0157 0.0527 0.1063

t (s) 720 780 810 870 900  


c (g mol Cu/L) 0.1433 0.1634 0.1722 0.1763 0.180  

The concentration desired at the break point is c/co = 0.010. Determine the break-point time,
fraction of total capacity used up to the break point, length of unused bed, and the saturation
loading capacity of the solid.
12.4 -4 .
Effect  of Tot a l C oncent r a t ion on Loa d ing  of Ion-Excha ng e R esin. Use the conditions of
Example 12.4-1 for ion exchange of Cu2+ with H+. However, determine the effect of total
concentration in the solution on the loading of Cu2+ on the resin. Do this for a total
concentration C of 0.010 N in the solution at equilibrium instead of 0.10 N. Also, the
concentration of Cu2+ in the solution is 0.002 M (0.004 N) instead of 0.02 M.
A8:    = 0.9132 equiv/L

Ans.
12.4 -5.

Eq u ilib r iu m in Ion Excha ng e of   for  H +. For the case where the cation   (A)


replaces H+ (B) in a polystyrene resin with 8% DVB, calculate the equilibrium constant KA,B.
The total resin capacity Q = 2.0 equiv/L wet bed volume. The total concentration C = 0.20 N in

the solution. Calculate at equilibrium the equivalents of   in the resin when the

concentration of   in solution is 0.04 N.
A9 :    = 0.6684 equiv/L

Ans.
12.5-1.
C omp osit ion of Tw o Liq u id  Pha ses in Eq u ilib r iu m. An original mixture weighing 200 kg
and containing 50 kg of isopropyl ether, 20 kg of acetic acid, and 130 kg of water is equilibrated
in a mixer–settler and the phases separated. Determine the amounts and compositions of the
raffinate and extract layers. Use equilibrium data from Appendix A.3.
12.5-2.
S ing le-S t a g e Ext r a ct ion. A single-stage extraction is performed in which 400 kg of a
solution containing 35 wt % acetic acid in water is contacted with 400 kg of pure isopropyl ether.
Calculate the amounts and compositions of the extract and raffinate layers. Solve for the
amounts both algebraically and by the lever-arm rule. What percent of the acetic acid is
removed? Use equilibrium data from Appendix A.3.
A11:Ans. L1 = 358 kg, xB1 = 0.715, xC1 = 0.03, V1 = 442 kg, y A1 = 0.11, y C1 = 0.86, 34.7% removed.
12.5-3.
S ing le-S t a g e Ext r a ct ion w it h Unk now n C omp osit ion. A feed mixture weighing 200 kg
of unknown composition containing water, acetic acid, and isopropyl ether is contacted in a
single stage with 280 kg of a mixture containing 40 wt % acetic acid, 10 wt % water, and 50 wt %
isopropyl ether. The resulting raffinate layer weighs 320 kg and contains 29.5 wt % acetic acid,
66.5 wt % water, and 4.0 wt % isopropyl ether. Determine the original composition of the feed
mixture and the composition of the resulting extract layer. Use equilibrium data from Appendix
A.3.

A12:Ans. xA0 = 0.032, xB0 = 0.948, y A1 = 0.15
12.5-4 .
Ext r a ct ion of Acet one in a  S ing le S t a g e. A mixture weighing 1000 kg contains 23.5 wt %
acetone and 76.5 wt % water and is to be extracted by 500 kg methyl isobutyl ketone in a single-
stage extraction. Determine the amounts and compositions of the extract and raffinate phases.
Use equilibrium data from Appendix A.3.
12.6 -1.
Flood ing  Velocit y  a nd  Tow er  Dia met er . Using the same flow rates for each stream and
feed conditions as in Ex. 12.6-1, with 1-in. Pall rings, design a tower for 50% of flooding with the
aqueous phase dispersed instead of the toluene phase. Compare results.
A14 :Ans. Diameter = 1.274 ft
12.6 -2.
Int er fa cia l Tension in Ext r a ct ion S y st em. Equilibrium data for the system water (A)–
acetic acid (C)–isopropyl ether (B) are given in the Appendix, Table A.3-24. Using the data in
dilute solution, where the wt fraction of acetic acid in the water-rich phase is 0.69%, calculate
the interfacial tension.
A15:Ans. σ = 20.28 dyn/cm
12.6 -3.
Per for a t ed -Pla t e Tr a y  Efficiency . An organic solvent is extracting an acid from a water
solution in a perforated plate tower. The dispersed organic solvent flow rate is 600 ft 3/h and the
continuous aqueous flow rate is 400 ft 3/h. The interfacial tension is 15 dyn/cm and the tray
spacing is 1.1 ft. The hole size is 0.40 cm. Estimate the tray efficiency. What happens if the
solvent flow rate is reduced to 400 ft 3/h?
A16 : Ans . E  = 0.133 (solvent 600 ft 3/h)
o
12.7-1.
M u lt ip le-S t a g e Ext r a ct ion w it h Fr esh S olv ent  in Ea ch S t a g e. Pure water is to be used
to extract acetic acid from 400 kg of a feed solution containing 25 wt % acetic acid in isopropyl
ether. Use equilibrium data from Appendix A.3.

a.  If 400 kg of water is used, calculate the percent recovery in the water solution in a one-
stage process.

b.  If a multiple three-stage system is used and 133.3 kg fresh water is used in each stage,
calculate the overall percent recovery of the acid in the total outlet water. (Hint: First,
calculate the outlet extract and raffinate streams for the first stage using 400 kg of feed
solution and 133 kg of water. For the second stage, 133 kg of water contacts the outlet
organic phase from the first stage. For the third stage, 133.3 kg of water contacts the
outlet organic phase from the second stage, and so on.)

12.7-2.
Ov er a ll Ba la nce in C ou nt er cu r r ent  S t a g e Ext r a ct ion. An aqueous feed of 200 kg/h
containing 25 wt % acetic acid is being extracted by pure isopropyl ether at the rate of 600 kg/h
in a countercurrent multistage system. The exit acid concentration in the aqueous phase is to
contain 3.0 wt % acetic acid. Calculate the compositions and amounts of the exit extract and
raffinate streams. Use equilibrium data from Appendix A.3.
12.7-3.
M inimu m S olv ent  a nd  C ou nt er cu r r ent  Ext r a ct ion of Acet one. An aqueous feed
solution of 1000 kg/h containing 23.5 wt % acetone and 76.5 wt % water is being extracted in a
countercurrent multistage extraction system using pure methylisobutyl ketone solvent at 298–
299 K. The outlet water raffinate will contain 2.5 wt % acetone. Use equilibrium data from
Appendix A.3.

a.  Calculate the minimum solvent that can be used. [Hint: In this case the tie line through
the feed L0 represents the condition for minimum solvent flow rate. This gives V1min .
Then draw lines LN V1min  and L0VN+1 to give the mixture point Mmin  and the coordinate
xAMmin. Using Eq. (12.7-4), solve for VN+1min, the minimum value of the solvent flow
rate VN+1.]

b.  Using a solvent flow rate of 1.5 times the minimum, calculate the number of theoretical
stages.

12.7-4 .
C ou nt er cu r r ent  Ext r a ct ion of Acet ic Acid  a nd  M inimu m S olv ent . An aqueous feed
solution of 1000 kg/h of acetic acid–water solution contains 30.0 wt % acetic acid and is to be
extracted in a countercurrent multistage process with pure isopropyl ether to reduce the acid
concentration to 2.0 wt % acid in the final raffinate. Use equilibrium data from Appendix A.3.

a.  Calculate the minimum solvent flow rate that can be used. (Hint: See Problem 12.7-3 for
the method to use.)

b.  If 2500 kg/h of ether solvent is used, determine the number of theoretical stages required.
(Note: It may be necessary to replot on an expanded scale the concentrations at the dilute
end.)

A20:Ans. (a) Minimum solvent flow rate VN+1 = 1630 kg/h; (b) 7.5 stages
12.7-5.
Nu mb er  of S t a g es in C ou nt er cu r r ent  Ext r a ct ion. Repeat Example 12.7-2 but use an exit
acid concentration in the aqueous phase of 4.0 wt %.
12.7-6 .
Ext r a ct ion w it h Immiscib le S olv ent s. A water solution of 1000 kg/h containing 1.5 wt %
nicotine in water is stripped with a kerosene stream of 2000 kg/h containing 0.05 wt % nicotine
in a countercurrent stage tower. The exit water is to contain only 10% of the original nicotine,
that is, 90% is removed. Use equilibrium data from Example 12.7-3. Calculate the number of
theoretical stages needed.

A22:Ans. 3.7 stages
12.7-7.
Nu mb er s of Tr a nsfer  Unit s for  Ext r a ct ion of Nicot ine. Using the data from Example
12.7-3 for nicotine extraction, replot the equilibrium and operating lines. For this system using a
packed tower, the height of a transfer unit has been estimated as HOL = 1.1 m. Calculate the
number of transfer units by two different methods and compare the values. Also calculate the
tower height.
A23:Ans. NOL = 5.76 transfer units (Eq. 12.7-22), z = 6.34 m
12.7-8.
M inimu m S olv ent  R a t e w it h Immiscib le S olv ent s. Determine the minimum solvent
kerosene rate to perform the desired extraction in Example 12.7-3. Using 1.50 times this
minimum rate, determine the number of theoretical stages needed graphically and also by using
the analytical equation.
A24 :Ans. V' = 153.8 kg/h, N = 6.86 analytically
12.7-9 .
S t r ip p ing  Nicot ine fr om K er osene. A kerosene flow of 100 kg/h contains 1.4 wt % nicotine
and is to be stripped with pure water in a countercurrent multistage tower. It is desired to
remove 90% of the nicotine. Using a water rate of 1.50 times the minimum, determine the
number of theoretical stages required. (Use the equilibrium data from Example 12.7-3.)
12.7-
Ext r a ct ion of Acet one fr om W a t er  a nd  Nu mb er  of Tr a nsfer  Unit s. Repeat Example
10.
12.7-4 for the extraction of acetone from water using 1.5 times the minimum solvent flow rate.
Do as follows:

a.  Graphically determine the number of theoretical steps needed.

b.  Calculate the number of steps using the analytical equation.

c.  For a packed tower with this system, the height of the transfer unit HOL has been
estimated as 0.9 m. Calculate the number of transfer units NOL and the tower height.

A26 :Ans. (b) N = 5.34 steps analytically; (c) NOL = 6.21 transfer units
12.7-11.
Pr ed ict ing  Ext r a ct ion for  Exist ing  Tow er  w it h a  G iv en Nu mb er  of S t ep s. An existing
tower contains 5.0 theoretical steps. It is desired to predict its performance under the following
conditions using the system water–acetone–trichloroethane given in Example 12.7-4. An inlet
water stream of 1000 kg/h containing 8.0 wt % acetone is extracted with 750 kg/h
trichloroethane containing 1.0 wt % acetone in this countercurrent tower at 25°C. Determine the
outlet concentration x1 in the water solution and in the trichloroethane solution using an
analytical equation. Also plot the equilibrium and operating lines and step off 5.0 steps. Assume
dilute solutions.
A27:Ans. x1 = 0.01205, y 2 = 0.0932
12.8-1.
Effect iv e Diffu siv it y  in Lea ching  Pa r t icles. In Example 12.8-1 a time of leaching of the
solid particle of 3.11 h is needed to remove 80% of the solute. Perform the following calculations:

a.  Using the experimental data, calculate the effective diffusivity, DAeff.

b.  Predict the time to leach 90% of the solute from the 2.0 mm particle.

A28: Ans.  (a) D  = 1.0 × 10−5 mm2/s; (b) t  = 5.00 h


Aeff
12.9 -1.
Lea ching  of Oil fr om S oy b ea ns in a  S ing le S t a g e. Repeat Example 12.9-1 for single-stage
leaching of oil from soybeans. The 100 kg of soybeans contains 22 wt % oil and the solvent feed is
80 kg of solvent containing 3 wt % soybean oil.
A29 :Ans. L1 = 52.0 kg, y A1 = 0.239, V1 = 50.0 kg, xA1 = 0.239, N1 = 1.5
12.9 -2.
Lea ching  a  S oy b ea n S lu r r y  in a  S ing le S t a g e. A slurry of flaked soybeans weighing a total
of 100 kg contains 75 kg of inert solids and 25 kg of solution with 10 wt % oil and 90 wt %
solvent hexane. This slurry is contacted with 100 kg of pure hexane in a single stage so that the
value of N for the outlet underflow is 1.5 kg insoluble solid/kg solution retained. Calculate the
amounts and compositions of the overflow V1 and the underflow L1 leaving the stage.
12.10-
C onst a nt  Und er flow  in Lea ching  Oil fr om M ea l. Use the same conditions as given in
1.
Example 12.10-1, but assume constant underflow of N = 1.85 kg solid/kg solution. Calculate the
exit flows and compositions and the number of stages required. Compare with Example 12.10-1.
A31:Ans. y AN  = 0.111, xA1 = 0.623, 4.3 stages
12.10-
Effect  of Less S olv ent  Flow  in Lea ching  Oil fr om M ea l. Use the same conditions as given
2.
in Example 12.10-1, but the inlet fresh-solvent-mixture flow rate per hour is decreased by 10%, to
1179 kg of benzene and 18 kg of oil. Calculate the number of stages needed.
12.10-
C ou nt er cu r r ent  M u lt ist a g e W a shing  of Or e. A treated ore containing inert solid gangue
3.
and copper sulfate is to be leached in a countercurrent multistage extractor using pure water to
leach the CuSO4. The solid charge rate per hour consists of 10 000 kg of inert gangue (B), 1200
kg of CuSO4 (solute A), and 400 kg of water (C). The exit wash solution is to contain 92 wt %
water and 8 wt % CuSO4. A total of 95% of the CuSO4 in the inlet ore is to be recovered. The
underflow is constant at N = 0.5 kg inert gangue solid/kg aqueous solution. Calculate the
number of stages required.
A33:Ans. 9 stages, LN  = 20 000 kg/h, y AN  = 0.0030, V1= 14 250 kg/h
12.10-
C ou nt er cu r r ent  M u lt ist a g e Lea ching  of Ha lib u t  Liv er s. Fresh halibut livers containing
4.
25.7 wt % oil are to be extracted with pure ethyl ether to remove 95% of the oil in a
countercurrent multistage leaching process. The feed rate is 1000 kg of fresh livers per hour. The
final exit overflow solution is to contain 70 wt % oil. The retention of solution by the inert solids
(oil-free liver) of the liver varies as follows (C1), where N is kg inert solid/kg solution retained
and y A is kg oil/kg solution:

N yA N yA N yA
4.88 0 2.47 0.4 1.39 0.81
3.50 0.2 1.67 0.6    

Calculate the amounts and compositions of the exit streams and the total number of theoretical
stages.

12.10-
C ou nt er cu r r ent  Lea ching  of Fla k ed  S oy b ea ns. Soybean flakes containing 22 wt % oil are
5.
to be leached in a countercurrent multistage process to contain 0.8 kg oil/100 kg inert solid
using fresh and pure hexane solvent. For every 1000 kg soybeans, 1000 kg hexane is used.
Experiments (S1) give the following retention of solution with the solids in the underflow, where
N is kg inert solid/kg solution retained and y A is wt fraction of oil in solution:

N yA

1.73 0
1.52 0.20
1.43 0.30

Calculate the exit flows and compositions and the number of theoretical stages needed.
12.11-1.
C r y st a lliza t ion of Ba (NO 3 ) 2 . A hot solution of Ba(NO3)2 from an evaporator contains 30.6
kg Ba(NO3)2/100 kg H2O and goes to a crystallizer, where the solution is cooled and Ba(NO3)2
crystallizes. On cooling, 10% of the original water present evaporates. For a feed solution of 100
kg total, calculate the following:

a.  The yield of crystals if the solution is cooled to 290 K (17°C), where the solubility is 8.6 kg
Ba(NO3)2/100 kg total water.

b.  The yield if cooled instead to 283 K, where the solubility is 7.0 kg Ba(NO3)2/100 kg total
water.

A36 :Ans. (a) 17.47 kg Ba(NO3)2 crystals
12.11-2.
Dissolv ing  a nd  S u b seq u ent  C r y st a lliza t ion. A batch of 1000 kg of KCl is dissolved in
sufficient water to make a saturated solution at 363 K, where the solubility is 35 wt % KCl in
water. The solution is cooled to 293 K, at which temperature its solubility is 25.4 wt %.

a.  What is the weight of water required for solution and the weight of crystals of KCl
obtained?

b.  What is the weight of crystals obtained if 5% of the original water evaporates on cooling?

A37:Ans. (a) 1857 kg water, 368 kg crystals; (b) 399 kg crystals
12.11-3.
C r y st a lliza t ion of M g S O 4  · 7H 2 O. A hot solution containing 1000 kg of MgSO4 and water
having a concentration of 30 wt % MgSO4 is cooled to 288.8 K, where crystals of MgSO4 · 7H2O
are precipated. The solubility at 288.8 K is 24.5 wt % anhydrous MgSO4 in the solution.
Calculate the yield of crystals obtained if 5% of the original water in the system evaporates on
cooling.
12.11-
Hea t  Ba la nce in C r y st a lliza t ion. A feed solution of 10 000 lbm at 130°F containing 47.0 lb
4.
FeSO4/100 lb total water is cooled to 80°F, where FeSO4 · 7H2O crystals are removed. The
solubility of the salt is 30.5 lb FeSO4/100 lb total water (P1). The average heat capacity of the
feed solution is 0.70 btu/lbm · °F. The heat of solution at 18°C is −4.4 kcal/g mol (−18.4 kJ/g
mol) FeSO4 · 7H2O (P1). Calculate the yield of crystals and make a heat balance. Assume that no
water is vaporized.
A39 :Ans. 2750 lbm FeSO4 · 7H2O crystals, q = −428 300 btu (−451 900 kJ)
12.11-5.
Effect  of Temp er a t u r e on Y ield  a nd  Hea t  Ba la nce in C r y st a lliza t ion. Use the
conditions given in Example 12.11-2, but the solution is cooled instead to 283.2 K, where the
solubility is 30.9 kg MgSO4/100 kg total water (P1). Calculate the effect on yield and the heat
absorbed by using 283.2 K instead of 293.2 K for the crystallization.
12.12-1.
G r ow t h a nd  Nu clea t ion R a t e in M S M PR  C r y st a llizer . Experimental data were obtained
for an MSMPR crystallizer (S2). The slurry density is 169 g/L, the crystal density ρ is 1.65 g/m3,
the residence time τ is 6.57 h, and the shape factor a is 0.98. The screen analysis of the crystals
is as follows:

Mesh Wt % Mesh Wt %

−14, +20 4.5 −35, +48 31.5


−20, +28 14.5 −48, +65 15.5

−28, +35 24.0 −65, +100 7.5

    −100 2.5

Using these data, do as follows:

a.  Calculate the population density, growth rate, and nucleation rate. Also calculate the
average size La .

b.  Using these calculated values, predict the cumulative weight fraction versus size L from
the experimental value of G and τ. Compare the predicted and experimental values.

A4 1:Ans. (a) G = 0.01673 mm/h; (b) For L = 0.589 mm, (1 − Wf) = 0.218
12.12-
Pr ed ict ion of C u mu la t iv e W eig ht  Fr a ct ion of C r y st a ls fr om G r ow t h R a t e. In
2.
Example 12.12-1, the growth rate G was determined to be 0.03244 mm/h for a residence time τ of
3.38 h. Using these values, predict the cumulative weight fraction versus size L. Compare the
predicted values with the experimental values.
A4 2:Ans. L = 0.589 mm, (1 − Wf) = 0.217; L = 0.417 mm, (1 − Wf) = 0.473
                             
                                                 
                                             
                                               
     

Chapter 13. Membrane Separation Processes
                             
                                                 
                                             
                                               
     

13.1. INTRODUCTION AND TYPES OF MEMBRANE SEPARATION
PROCESSES

13.1A. Intr od u ction

Separations by the use of membranes are becoming increasingly important in the process industries. In
this relatively new separation process, the membrane acts as a semipermeable barrier and separation
occurs by the membrane controlling the rate of movement of various molecules between two liquid
phases, two gas phases, or a liquid and a gas phase. The two fluid phases are usually miscible and the
membrane barrier prevents actual, ordinary hydro-dynamic flow. A classification of the main types of
membrane separation follows.

13.1B. C lassification of M e m b r ane  Pr oce sse s

1. G a s d iffu sion in p or ou s solid

In this type a gas phase is present on both sides of the membrane, which is a microporous solid. The rates
of molecular diffusion of the various gas molecules depend on the pore sizes and the molecular weights.
This type of diffusion in the molecular, transition, and Knudsen regions was discussed in detail in
Section 7.6.

2. Liq u id  p er mea t ion or  d ia ly sis

In this case, the small solutes in one liquid phase diffuse readily because of concentration differences
through a porous membrane to the second liquid (or vapor) phase. Passage of large molecules through
the membrane is more difficult. This membrane process has been applied in chemical processing
separations such as separation of H2SO4 from nickel and copper sulfates in aqueous solutions, food
processing, and artificial kidneys, and will be covered in detail in Section 13.2. In electrodialysis,
separation of ions occurs by imposing an emf difference across the membrane.

3. G a s p er mea t ion in a  memb r a ne

The membrane in this process is usually a polymer such as rubber, polyamide, and so on, and is not a
porous solid. The solute gas first dissolves in the membrane and then diffuses in the solid to the other gas
phase. This was discussed in detail in Section 6.5 for solutes following Fick's law and will be considered
again, for the case where resistances are present, in Section 13.3A. In Sections 13.3 to 13.8, different
process flow patterns are considered. Examples of membrane separations are helium being separated
from natural gas and nitrogen from air. Separation of a gas mixture occurs because each type of molecule
diffuses at a different rate through the membrane.

4 . R ev er se osmosis

A membrane, which impedes the passage of a low-molecular-weight solute, is placed between a solute-
solvent solution and a pure solvent. The solvent diffuses into the solution by osmosis. In reverse osmosis,
a reverse pressure difference is imposed which causes the flow of solvent to reverse, as in the desalination
of seawater. This process is also used to separate other low-molecular-weight solutes, such as salts,
sugars, and simple acids from a solvent (usually water). This process will be covered in detail in Sections
13.9 and 13.10.

5. Ult r a filt r a t ion memb r a ne p r ocess

In this process, pressure is used to obtain a separation of molecules by means of a semipermeable
polymeric membrane (M2). The membrane discriminates on the basis of molecular size, shape, or
chemical structure and separates relatively high-molecular-weight solutes such as proteins, polymers,
colloidal materials such as minerals, and so on. The osmotic pressure is usually negligible because of the
high molecular weights. This will be covered in Section 13.11.

6 . M icr ofilt r a t ion memb r a ne p r ocess

In microfiltration, pressure-driven flow through the membrane is used to separate micron-size particles
from fluids. The particles are usually larger than those in ultrafiltration. Examples are separation of
bacteria, paint pigment, yeast cells, and so on from solutions. This process will be covered in Section
13.12.

7. G el p er mea t ion chr omot og r a p hy

The porous gel retards diffusion of the high-molecular-weight solutes. The driving force is concentration.
This process is quite useful in analyzing complex chemical solutions and in the purification of very
specialized and/or valuable components.
                             
                                                 
                                             
                                               
     

13.2. LIQUID PERMEATION MEMBRANE PROCESSES OR DIALYSIS

13.2A. S e r ie s R e sistance s in M e m b r ane  Pr oce sse s

In membrane processes with liquids, the solute molecules must first be transported or diffuse through
the liquid film of the first liquid phase on one side of the solid membrane, then through the membrane
itself, and finally through the film of the second liquid phase. This is shown in Fig. 13.2-1a, where c1 is

the bulk liquid-phase concentration of the diffusing solute A in kg mol A/m3, c1i is the concentration of A
in the fluid just adjacent to the solid, and c1iS is the concentration of A in the solid at the surface and is in
equilibrium with C 1i. The mass-transfer coefficients are kc1 and kc2 in m/s. The equilibrium distribution
coefficient K' is defined as

Equation 13.2-1

Figure 13.2-1. Concentr ation profiles for membrane processes: (a) two liquid films and a solid, (b) two gas
films and a solid.

Note that K' is the inverse of K defined in Eq. (7.1-16).

The flux equations through each phase are all equal to each other at steady state and are as follows:

Equation 13.2-2
Substituting c1iS = K'c1i and c2iS = K'c2i into Eq. (13.2-2),

Equation 13.2-3

Equation 13.2-4

where pM is the permeance in the solid in m/s, L is the thickness in m, and DAB is the diffusivity of A in

the solid in m2/s. Note that the permeance pM in Eq. (13.2-4) is different from the permeability PM
defined in Eq. (6.5-9). Also, the value of pM is inversely proportional to the thickness L. Instead of
determining DAB and K' in two separate experiments, it is more convenient to determine pM in one
separate diffusion experiment. Solving each of the parts of Eq. (13.2-3) for the concentration difference,

Equation 13.2-5

Adding the equations, the internal concentrations c1i and c2i drop out, and the final equation is

Equation 13.2-6

In some cases, the resistances in the two liquid films are quite small compared to the membrane
resistance, which controls the permeation rate.

EXAMPLE 13.2­1. Membrane Diffusion and Liquid Film
Resistances
A liquid containing dilute solute A at a concentration c1 = 3 × 10-2 kg mol/m3 is flowing

rapidly past a membrane of thickness L = 3.0 × 10-5 m. The distribution coefficient K' = 1.5
and DAB = 7.0 × 10-11 m2/s in the membrane. The solute diffuses through the membrane, and
its concentration on the other side is c2 = 0.50 × 10-2 kg mol/m3. The mass-transfer coefficient

kc1 is large and can be considered as infinite, and kc2 = 2.02 × 10-5 m/s.

a.  Derive the equation to calculate the steady-state flux NA and make a sketch.

b.  Calculate the flux and the concentrations at the membrane interfaces.

S olu t ion: For part (a), the sketch is shown in Fig. 13.2-2. Note that the concentration profile
on the left side is flat (kc1 = ∞) and c1 = c1i. The derivation is the same as for Eq. (13.2-6), but
1/kc1 = 0 to give

Equation 13.2-7

Figure 13.2-2. Concentr ations for Example 13.2-1.

For part (b), to calculate the flux using Eqs. (13.2-4) and (13.2-7),

To calculate c2i,
Solving, c2i = 0.869 × 10-2 kg mol/m3. Also, using Eq. (13.2-1),

Solving, c2is = 1.304 × 10-2 kg mol/m3.

13.2B. Dialysis Pr oce sse s

Dialysis uses a semipermeable membrane to separate species by virtue of their different diffusion rates in
the membrane. The feed solution or dialyzate, which contains the solutes to be separated, flows on one
side of the membrane and the solvent or diffusate stream on the other side. Some solvent may also diffuse
across the membrane in the opposite direction, which reduces performance by diluting the dialyzate.

In practice dialysis is used to separate species which differ appreciably in size and thus have a reasonably
large difference in diffusion rates. Solute fluxes depend on the concentration gradient in the membrane.
Hence, dialysis is characterized by low flux rates in comparison to other membrane processes, such as
reverse osmosis and ultrafiltration, which depend on applied pressure.

In general, dialysis is used with aqueous solutions on both sides of the membrane. The film resistances
can be appreciable compared to the membrane resistance. Applications include recovery of sodium
hydroxide in cellulose processing, recovery of acids from metallurgical liquors, removal of products from
a culture solution in fermentation, desalting of cheese whey solids, and reduction of alcohol content of
beer. Many small-scale applications occur in the pharmaceutical industry.

13.2C . Typ e s of Eq u ip m e nt for  Dialysis

Various geometrical configurations are used in liquid membrane processes. A common one is similar to a
filter press, where the membrane is a flat plate. Vertical solid membranes are placed in between
alternating liquor and solvent feed frames, with the liquor to be dialyzed being fed to the bottom and the
solvent to the top of these frames. The dialyzate and the diffusate are removed through channels located
at the top and bottom of the frames, respectively. The most important type consists of many small tubes
or very fine hollow fibers arranged in a bundle, like a heat exchanger. This type of unit has a very high
ratio of membrane area to volume of the unit.

13.2D. He m od ialysis in Ar tificial K id ne y

An important example of the liquid permeation process is dialysis with an artificial kidney in the
biomedical field. In this application for purifying human blood, the principal solutes removed are the
small solutes urea, uric acid, creatinine, phosphates, and excess amounts of chloride. A typical
membrane used is cellophane about 0.025 mm thick, which allows small solutes to diffuse but retains
the large proteins in the blood. During the hemodialysis, blood is passed on one side of the membrane
while an aqueous dialyzing fluid flows on the other side. Solutes such as urea, uric acid, NaCl, and so on,
which have elevated concentrations in the blood, diffuse across the membrane to the dialyzing aqueous
solution, which contains certain concentrations of solutes such as potassium salts, and so on, to ensure
that concentrations in the blood do not drop below certain levels. In one configuration the membranes
are stacked in the form of a multilayered sandwich, with blood flowing past one side of the membrane
and dialyzing fluid past the other side. The hollow fiber type is used quite often.
EXAMPLE 13.2­2. Dialysis to Remove Urea from Blood
Calculate the flux and the rate of removal of urea at steady state in g/h from blood in a
cuprophane (cellophane) membrane dialyzer at 37°C. The membrane is 0.025 mm thick and
has an area of 2.0 m2. The mass-transfer coefficient on the blood side is estimated as kc1 = 1.25

× 10-5 m/s and that on the aqueous side is 3.33 × 10-5 m/s. The permeance of the membrane is
8.73 × 10-6 m/s (B2). The concentration of urea in the blood is 0.02 g urea/100 mL and that in
the dialyzing fluid will be assumed as 0.

S olu t ion: The concentration c1 = 0.02/100 = 2.0 × 10-4 g/mL = 200 g/m3 and c2 = 0.
Substituting into Eq. (13.2-6),

For a time of 1 h and an area of 2.0 m2,
                             
                                                 
                                             
                                               
     

13.3. GAS PERMEATION MEMBRANE PROCESSES

13.3A. S e r ie s R e sistance s in M e m b r ane  Pr oce sse s

In membrane processes with two gas phases and a solid membrane, similar equations can be written for
the case illustrated in Fig. 13.2-1b. The equilibrium relation between the solid and gas phases is given by

Equation 13.3-1

where S is the solubility of A in m3 (STP)/atm · m3 solid, as shown in Eq. (6.5-5), and H is the
equilibrium relation in kg mol/m3 · atm. This is similar to Henry's law. The flux equations in each phase
are as follows:

Equation 13.3-2

Equation 13.3-3

Equation 13.3-4

The permeability PM given previously is

Equation 6.5-9
The permeability PM is given in kg mol units by dividing Eq. (6.5-9) by 22.414 m3/kg mol:

Equation 13.3-5

Then the flux NA through the membrane given by Eq. (13.3-3) becomes

Equation 13.3-6

Eliminating the interfacial concentrations as before,

Equation 13.3-7

In the case where pure A (pA1) is on the left side of the membrane, there is no diffusional resistance in the
gas phase, and kc1 can be considered to be infinite. Note that kG1 = kc1/RT.

An example of gas permeation in a membrane is the use of a polymeric membrane as an oxygenator for a
heart-lung machine to oxygenate blood. In this biomedical application, pure O2 gas is on one side of a
thin membrane and blood is on the other side. Oxygen diffuses through the membrane into the blood and
CO2 diffuses in a reverse direction into the gas stream.

13.3B. Typ e s of M e m b r ane s and  Pe r m e ab ilitie s for  S e p ar ation of G ase s

1. Ty p es of d ense-p ha se sy mmet r ic memb r a nes

Early membranes were limited in their use because of low selectivities in separating two gases and quite
low permeation fluxes. This low-flux problem was due to the fact that the membranes had to be relatively
thick (1 mil or 1/1000 of an inch or greater) in order to avoid tiny holes, which reduced the separation by
allowing viscous or Knudsen flow of the feed. Development of silicone polymers (1 mil thickness)
increased the permeability by factors of 10–20 or so. These are called dense-phase symmetric
membranes.

2. Ty p es of a sy mmet r ic memb r a nes

Newer asymmetric membranes include a very thin but dense skin on one side of the membrane supported

by a porous substructure (R1). The dense skin has a thickness of about 1000   and the porous support
thickness is about 25–100 μm. The flux increase of these membranes is thousands of time higher than
the 1-mil-thick original membranes. Some typical materials currently used for asymmetric membranes
are a composite of polysulfone coated with silicone rubber, cellulose acetate and modified cellulose
acetates, aromatic polyamides or aromatic polyimides, and silicone-polycarbonate copolymer on a
porous support.

3. Per mea b ilit y  of memb r a nes

The permeability PM in Eqs. (6.5-9) and (13.3-6) is defined as DABS in m3 (STP)/s · m2C.S. · atm/m.

Since mixtures of gases are often present,   for gas A and   for gas B will be used instead of PM. The


different sets of units used and their conversion factors are given in Table 13.3-1. Sometimes units are
given in terms of Barrers, as also defined in Table 13.3-1.

Table 13.3-1. Conversion Factors for Permeability    and Permeance  /t

   
Permeability , Permeance, /t

The accurate prediction of permeabilities of gases in membranes is generally not possible, and
experimental values are needed. Experimental data for common gases in some typical dense-phase
membranes are given in Table 13.3-2. Note that there are wide differences among the permeabilities of
various gases in a given membrane. Silicone rubber exhibits very high permeabilities for the gases in the
table.

Table 13.3-2. Permeabilities of Various Gases in Dense-Phase Symmetr ic Membranes

  , 

Permeability
Material Temp. (°C) He H2 CH4 CO2 O2 N2 Ref.

Silicone 25 300 550 800 2700 500 250 (S2)


rubber

Natural rubber 25 31 49 30 131 24 8.1 (S2)


Polycarbonate 25–30 15 12   5.6,10 1.4   (S2)
(Lexane)
Nylon 66 25 1.0     0.17 0.034 0.008 (S2)
Polyester —   1.65 0.035 0.31   0.031 (H1)
(Permasep)

Silicone- 25   210   970 160 70 (W2)


polycarbonate
copolymer
(57% silicone)
Teflon FEP 30 62   1.4     2.5 (S1)

Ethyl cellulose 30 35.7 49.2 7.47 47.5 11.2 3.29 (W3)


Polystyrene 30 40.8 56.0 2.72 23.3 7.47 2.55 (W3)

For the effect of temperature T in K, ln   is approximately a linear function of 1/T and increases with T.
However, operation at high temperatures can often degrade the membranes. When a mixture of gases is
present, reductions of permeability of an individual component of up to 10% or so can often occur. In a
few cases, much larger reductions have been observed (R1). Hence, when using a mixture of gases,
experimental data should be obtained to determine if there is any interaction between the gases. The
presence of water vapor can have similar effects on the permeabilities and can also possibly damage the
membranes.

4 . Per mea nce of memb r a nes

In many cases, especially in asymmetric membranes, the thickness t is not measured and only

experimental values of permeance  /t are given. Conversion factors are also given in Table 13.3-1.

13.3C . Typ e s of Eq u ip m e nt for  G as Pe r m e ation M e m b r ane  Pr oce sse s

1. Fla t  memb r a nes

Flat membranes are mainly used in experiments to characterize the permeability of the membrane. The
modules are easy to fabricate and use and the areas of the membranes are well defined. In some cases
modules are stacked together like a multilayer sandwich or plate-and-frame filter press. The major
drawback of this type is the very small membrane area per unit separator volume. Small commercial flat
membranes are used for producing oxygen-enriched air for individual medical applications.

2. S p ir a l-w ou nd  memb r a nes

This configuration retains the simplicity of fabricating flat membranes while increasing markedly the
membrane area per unit separator volume up to 100 ft 2/ft 3 (328 m2/m3) and decreasing pressure drops
(R1). The assembly consists of a sandwich of four sheets wrapped around a central core of a perforated
collecting tube. The four sheets consist of a top sheet of an open separator grid for the feed channel, a
membrane, a porous felt backing for the permeate channel, and another membrane, as shown in Fig.
13.3-1. The spiral-wound element is 100 to 200 mm in diameter and is about 1 to 1.5 m long in the axial
direction. The flat sheets before rolling are about 1-1.5 m by about 2-2.5 m. The space between the
membranes (open grid for feed) is about 1 mm and the thickness of the porous backing (for permeate) is
about 0.2 mm.
Figure 13.3-1. Spiral-wound elements  and assembly. [From R. I. Berry, Chem. Eng., 88 (July 13), 63 (1981).
With permission.]

The whole spiral-wound element is located inside a metal shell. The feed gas enters at the left end of the
shell, enters the feed channel, and flows through this channel in the axial direction of the spiral to the
right end of the assembly (Fig. 13.3-1). Then the exit residue gas leaves the shell at this point. The feed
stream, which is in the feed channel, permeates perpendicularly through the membrane. This permeate
then flows through the permeate channel in a direction perpendicular to the feed stream toward the
perforated collecting tube, where it leaves the apparatus at one end. This is illustrated in Fig. 13.3-2,
where the local gas flow paths are shown for a small element of the assembly.

Figure 13.3-2. Local gas flow paths for spiral-wound separator.
3. Hollow -fib er  memb r a nes

The membranes are in the shape of very-small-diameter hollow fibers. The inside diameter of the fibers is
in the range of 100–500 μm and the outside 200–1000 μm, with the length up to 3-5 m. The module
resembles a shell-and-tube heat exchanger. Thousands of fine tubes are bound together at each end into a
tube sheet that is surrounded by a metal shell having a diameter of 0.1-0.2 m, so that the membrane area
per unit volume is up to 10 000 m2/m3, as in Fig. 13.3-3. A typical large industrial permeator has fibers
of 200 μm ID and 400 μm OD in a shell 6 in. in diameter and 10 ft long (P7).

Figure 13.3-3. Hollow-fiber separator assembly.
Typically, the high-pressure feed enters the shell side at one end and leaves at the other end. The hollow
fibers are closed at one end of the tube bundles. The permeate gas inside the fibers flows countercurrent to
the shell-side flow and is collected in a chamber where the open ends of the fibers terminate. Then the
permeate exits the device.

In some lower-pressure operations, such as for separation of air to produce nitrogen, the feed enters
inside the tubes (P7).

13.3D. Intr od u ction to Typ e s of Flow  in G as Pe r m e ation

1. Ty p es of flow  a nd  d iffu sion g r a d ient s

In a membrane process, high-pressure feed gas is supplied to one side of the membrane and permeates
normal to the membrane. The permeate leaves in a direction normal to the membrane, accumulating on
the low-pressure side. Because of the very high diffusion coefficient in gases, concentration gradients in
the gas phase in the direction normal to the surface of the membrane are quite small. Hence, gas film
resistances compared to the membrane resistance can be neglected. This means that the concentration in
the gas phase in a direction perpendicular to the membrane is essentially uniform, whether the gas
stream is flowing parallel to the surface or is not flowing.

If the gas stream is flowing parallel to the membrane in essentially plug flow, a concentration gradient
occurs in this direction. Hence, several cases can occur in the operation of a membrane module. The
permeate side of the membrane can be operated so that the phase is completely mixed (uniform
concentration) or so that the phase is in plug flow. The high-pressure feed side can also be completely
mixed or in plug flow. Countercurrent or cocurrent flow can be used when both sides are in plug flow.
Hence, separate theoretical models must be derived for these different types of operation, as given in
Sections 13.4–13.8.

2. Assu mp t ions u sed  a nd  id ea l flow  p a t t er ns

In deriving theoretical models for gas separation by membranes, isothermal conditions and negligible
pressure drop in the feed stream and permeate stream are generally assumed. It is also assumed that the
effects of total pressure and/or composition of the gas are negligible and that the permeability of each
component is constant (i.e., no interactions between different components).

Since there are a number of idealized flow patterns, the important types are summarized in Fig. 13.3-4. In
Fig. 13.3-4a, complete mixing is assumed for the feed chamber and the permeate chamber. Similar to a
continuous-stirred tank, the reject or residue and the product or permeate compositions are equal to their
respective uniform compositions in the chambers.

Figure 13.3-4. Ideal flow patte rns in a membrane separator for gases: (a) complete mixing, (b) cross-flow, (c)
countercurrentfl ow, (d) cocurrent flow.
An ideal cross-flow pattern is given in Fig. 13.3-4b, where the feed stream is in plug flow and the
permeate flows in a normal direction away from the membrane without mixing. Since the feed
composition varies along its flow path, the local permeate concentration also varies along the membrane
path.

In Fig. 13.3-4c, both the feed stream and permeate stream are in plug flow countercurrent to each other.
The composition of each stream varies along its flow path. Cocurrent flow of the feed and permeate
streams is shown in Fig. 13.3-4d.
                             
                                                 
                                             
                                               
     

13.4. COMPLETE­MIXING MODEL FOR GAS SEPARATION BY
MEMBRANES

13.4 A. Basic Eq u ations Use d

In Fig. 13.4-1, a detailed process flow diagram is shown for complete mixing. When a separator element
is operated at a low recovery (i.e., where the permeate flow rate is a small fraction of the entering feed
rate), there is a minimal change in composition. Then the results derived using the complete-mixing
model provide reasonable estimates of permeate purity. This case was derived by Weller and Steiner
(W4).

Figure 13.4-1. Process flow for complete mixing case.

Using nomenclature similar to that for distillation (P7), using the feed and nonpermeate flow rate as L
and composition x mole fraction and the permeate flow rate as V and composition y.

The overall material balance (Fig. 13.4-1) is as follows:

Equation 13.4-1

where Lf is total feed flow rate in cm3 (STP)/s; Lo is outlet reject flow rate, cm3 (STP)/s; and Vp is outlet

permeate flow rate, cm3 (STP)/s. The cut or fraction of feed permeated, θ, is given as

Equation 13.4-2
The rate of diffusion or permeation of species A (in a binary of A and B) is given below by an equation
similar to Eq. (13.3-6) but using cm3 (STP)/s as rate of permeation rather than flux in kg mol/s · cm2:

Equation 13.4-3

where   is permeability of A in the membrane, cm3 (STP) · cm/(s · cm2 · cm Hg); VA is flow rate of A in

permeate, cm3 (STP)/s; Am is membrane area, cm2; t is membrane thickness, cm; ph is total pressure in
the high-pressure (feed) side, cm Hg; pl is total pressure in the low-pressure or permeate side, cm Hg: xo
is mole fraction of A in reject side; xf is mole fraction of A in feed; and y p is mole fraction of A in permeate.
Note that phxo is the partial pressure of A in the reject gas phase and ply p is the partial pressure in the
permeate side. A similar equation can be written for component B.

Equation 13.4-4

Where   is permeability of B, cm3 (STP) · cm/(s · cm2 · cm Hg). The ideal separation factor   is

Equation 13.4-5

Dividing Eq. (13.4-3) by (13.4-4),

Equation 13.4-6

This equation relates the reject concentration xo to the permeate concentration y p. The concentration in
the bulk or reject gas phase is xo. The permeate concentration y p in the bulk gas phase is the same as the
gas concentration y' on the lower-pressure side immediately adjacent to the dense-phase membrane or
on the low-pressure side of the dense skin layer of the asymmetric membrane, which is called the
interface or local concentration.

Equation (13.4-6) is a quadratic equation and its solution is
Equation 13.4-7

where
[View full size image]

Making an overall material balance on component A,

Equation 13.4-8

Dividing by Lf and solving for the outlet reject composition,

Equation 13.4-9

Substituting Vp = θLf from Eq. (13.4-2) into Eq. (13.4-3) and solving for the membrane area, Am,

Equation 13.4-10

13.4 B. S olu tion of Eq u ations for  De sign of C om p le te -M ixing C ase

For design of a system, there are seven variables in the complete-mixing model (H1), xf, xo, y p, θ,  ,
pl/ph, and Am, four of which are independent variables. Two commonly occurring cases are considered
here.

C a se 1

This is the simplest case, where xf, xo,  , and pl/ph are given and y p, θ, and Am are to be determined by


solution of the equations. By use of the quadratic equation, Eq. (13.4-7) is solved for the permeate
composition y p in terms of xo. Hence, to solve this case, y p is first calculated using Eq. (13.4-7). Then the
fraction of feed permeated, θ, is calculated using Eq. (13.4-9) and the membrane area, Am, using Eq.
(13.4-10).

EXAMPLE 13.4­1. Design of a Membrane Unit for Complete
Mixing
A membrane is to be used to separate a gaseous mixture of A and B whose feed flow rate is Lf =

1 × 104 cm3 (STP)/s and feed composition of A is xf = 0.50 mole fraction. The desired

composition of the reject is xo = 0.25. The membrane thickness t = 2.54 × 10-3 cm, the pressure
on the feed side is ph = 80 cm Hg, and on the permeate side it is pl = 20 cm Hg. The

permeabilities are   = 50 × 10-10 cm3 (STP) · cm/(s · cm2 · cm Hg) and   = 5 × 10-10.


Assuming the complete-mixing model, calculate the permeate composition, y p, the fraction
permeated, θ, and the membrane area, Am.

S olu t ion: Substituting into Eq. (13.4-5),

Using Eq. (13.4-7),

Using the material-balance equation (13.4-9),
Solving, θ = 0.706. Also, using Eq. (13.4-10),

C a se 2

In this case xf, θ,  , and pl/ph are given and y p, xo, and Am are to be determined. Equation (13.4-7)


cannot be solved for y p since xo is unknown. Hence, xo from Eq. (13.4-9) is substituted into Eq. (13.4-7)
and the resulting equation solved for y p using the quadratic equation, to give

Equation 13.4-11

where

After solving for y p, the value of xo is calculated from Eq. (13.4-9) and Am from Eq. (13.4-10).

EXAMPLE 13.4­2. Membrane Design for Separation of Air
It is desired to determine the membrane area needed to separate an air stream using a

membrane 1 mil thick with an oxygen permeability of   = 500 × 10-10 cm3 (STP) · cm/(s ·
cm2 · cm Hg). An   = 10 for oxygen permeability divided by nitrogen permeability (S6) will
be used. The feed rate is Lf = 1 × 106 cm3 (STP)/s and the fraction cut θ = 0.20. The pressures
selected for use are ph = 190 cm Hg and pl = 19 cm Hg. Again, assuming the complete-mixing
model, calculate the permeate composition, the reject composition, and the area.

S olu t ion: Using Eq. (13.4-11) for a feed composition of xf = 0.209,

Substituting into Eq. (13.4-9),

Finally, using Eq. (13.4-10) to find the area,
13.4 C . M inim u m  C once ntr ation of R e je ct S tr e am

If all of the feed is permeated, then θ = 1 and the feed composition xf = y p. For all values of θ < 1, the
permeate composition y p > xf (H1). Substituting the value xf = y p into Eq. (13.4-7) and solving, the
minimum reject composition xoM for a given xf value is obtained as

Equation 13.4-12

Hence, a feed of xf concentration cannot be stripped lower than a value of xoM even with an infinitely
large membrane area for a completely mixed system. To strip beyond this limiting value, a cascade-type
system could be used. However, a single unit which is not completely mixed but is designed for plug flow
could also be used.

EXAMPLE 13.4­3. Effect of Feed Composition on Minimum
Reject Concentration
Calculate the minimum reject concentration for Example 13.4-1 where the feed concentration
is xf = 0.50. Also, what is the effect of raising the feed purity to xf = 0.65?

S olu t ion: Substituting xf = 0.50 into Eq. (13.4-12),

For xf = 0.65,
                             
                                                 
                                             
                                               
     

13.5. COMPLETE­MIXING MODEL FOR MULTICOMPONENT
MIXTURES

13.5A. De r iv ation of Eq u ations

When multicomponent mixtures are present, the iteration method of Stern et al. (S1) is quite useful. This
method will be derived for a ternary mixture of components A, B, and C. The process flow diagram is the
same as Fig. 13.4-1, where the feed composition xf is xfA, xfB, and xfC. The known values are

The unknown values to be determined are

These eight unknowns can be obtained by solving a set of eight simultaneous equations using an
iteration method. Three rate-of-permeation equations similar to Eq. (13.4-3) are as follows for
components A, B, and C:

Equation 13.5-1

Equation 13.5-2

Equation 13.5-3

The three material-balance equations similar to Eq. (13.4-9) are written for components A, B, and C:

Equation 13.5-4
Equation 13.5-5

Equation 13.5-6

Also, two final equations can be written as

Equation 13.5-7

Equation 13.5-8

Substituting xoA from Eq. (13.5-4) into Eq. (13.5-1) and solving for Am,

Equation 13.5-9

For component B, Eq. (13.5-5) is substituted into Eq. (13.5-2), giving

Equation 13.5-10
Rearranging Eq. (13.5-10) and solving for y pB,

Equation 13.5-11

In a similar manner Eq. (13.5-12) is derived for y pC:

Equation 13.5-12

13.5B. Ite r ation S olu tion Pr oce d u r e  for  M u lticom p one nt M ixtu r e s

The following iteration or trial-and-error procedure can be used to solve the equations above:

1. A value of y pA is assumed where y pA > xfA.

2. Using Eq. (13.4-2) and the known value of θ, Vp is calculated.

3. The membrane area is calculated from Eq. (13.5-9).

4 . Values of y pB and y pC are calculated from Eqs. (13.5-11) and (13.5-12).

5. The sum Σn  y pn  is calculated from Eq. (13.5-7). If this sum is not equal to 1.0. steps 1 through 5 are
repeated until the sum is 1.0.

6 . Finally, xoA, xoB, and xoC are calculated from Eqs. (13.5-4), (13.5-5), and (13.5-6).

EXAMPLE 13.5­1. Design of Membrane Unit for
Multicomponent Mixture
A multicomponent gaseous mixture having a composition of xfA = 0.25, xfB = 0.55, and xfC =

0.20 is to be separated by a membrane with a thickness of 2.54 X 10-3 cm using the complete-

mixing model. The feed flow rate is 1.0 × 104 cm3 (STP)/s and the permeabilities are   = 200

× 10-10 cm3 (STP) · cm/(s · cm2 · cm Hg),   = 50 × 10-10, and   = 25 × 10-10. The pressure


on the feed side is 300 cm Hg and 30 cm Hg on the permeate side. The fraction permeated will
be 0.25. Calculate the permeate composition, reject composition, and membrane area using
the complete-mixing model.

S olu t ion: Following the iteration procedure, a value of y pA = 0.50 is assumed. Substituting


into Eq. (13.4-2) for step 2,

Using Eq. (13.5-9), the membrane area for step (3) is

Following step 4, the values y pB and y pC are calculated using Eqs. (13.5-11) and (13.5-12):

[View full size image]

[View full size image]

Substituting into Eq. (13.5-7),

For the second iteration, assuming that y pA = 0.45, the following values are calculated:
The final iteration values are Am = 3.536 × 106 cm2; y pA = 0.4555, y pB = 0.4502, and y pC =
0.0943. Substituting into Eqs. (13.5-4), (13.5-5), and (13.5-6),
                             
                                                 
                                             
                                               
     

13.6. CROSS­FLOW MODEL FOR GAS SEPARATION BY
MEMBRANES

13.6 A. De r iv ation of Basic Eq u ations

A detailed flow diagram for the cross-flow model derived by Weller and Steiner (W3, W4) is shown in Fig.
13.6-1. In this case the longitudinal velocity of the high-pressure or reject stream is large enough that this
gas stream is in plug flow and flows parallel to the membrane. On the low-pressure side the permeate
stream is almost pulled into vacuum, so that the flow is essentially perpendicular to the membrane.

Figure 13.6-1. Process flow diagram for cross-flow model.

This model assumes no mixing in the permeate side as well as no mixing on the high-pressure side.
Hence, the permeate composition at any point along the membrane is determined by the relative rates of
permeation of the feed components at that point. This cross-flow pattern approximates that in an actual
spiral-wound membrane separator (Fig. 13.3-1) with a high-flux asymmetric membrane resting on a
porous felt support (P2, R1).

Referring to Fig. 13.6-1, the local permeation rate over a differential membrane area dAm at any point in
the stage is

Equation 13.6-1

Equation 13.6-2
where dL = dV and is the total flow rate permeating through the area dAm. Dividing Eq. (13.6-1) by
(13.6-2) gives

Equation 13.6-3

This equation relates the permeate composition y  to the reject composition x at a point along the path. It
is similar to Eq. (13.4-6) for complete mixing. Hwang and Kammermeyer (H1) give a computer program
for the solution of the above system of differential equations by numerical methods.

Weller and Steiner (W3, W4) used some ingenious transformations and were able to obtain an analytical
solution to the three equations as follows:

Equation 13.6-4

where
The term uf is the value of u at i = if = xf/(1 - xf). The value of θ* is the fraction permeated up to the value
of x in Fig. 13.6-1. At the outlet where x = x0, the value of θ* is equal to θ, the total fraction permeated.
The composition of the exit permeate stream is y p and is calculated from the overall material balance, Eq.
(13.4-9).

The total membrane area was obtained by Weller and Steiner (W3, W4) using some additional
transformations of Eqs. (13.6-1)-(13.6-3) to give

Equation 13.6-5

where

Values of θ* in the integral can be obtained from Eq. (13.6-4). The integral can be calculated numerically.
The term if is the value of i at the feed xf, and io is the value of i at the outlet xo. A shortcut approximation
of the area without using a numerical integration, available from Weller and Steiner (W3), has a
maximum error of about 20%.

13.6 B. Pr oce d u r e  for  De sign of C r oss-Flow  C ase

In the design for the complete-mixing model there are seven variables, and two of the most common
cases were discussed in Section 13.4B. Similarly, for the cross-flow model these same common cases
occur.

C a se 1

The values of xf, xo, α*, and pl/ph are given and y p, θ and Am are to be determined. The value of θ* or θ
can be calculated directly from Eq. (13.6-4) since all other values in this equation are known. Then y p is
calculated from Eq. (13.4-9). To calculate the area Am, a series of values of x less than the feed xf and
greater than the reject outlet xo are substituted into Eq. (13.6-4) to give a series of θ* values. These values
are then used to numerically or graphically integrate Eq. (13.6-5) to obtain the area Am.

C a se 2

In this case the values of xf, θ, α*, and pl/ph are given and y p, xo, and Am are to be determined. This is
trial and error, where values of xo are substituted into Eq. (13.6-4) to solve the equation. The membrane
area is calculated as in Case 1.

EXAMPLE 13.6­1. Design of a Membrane Unit Using
Cross-Flow
The same conditions for the separation of an air stream as given in Example 13.4-2 for
complete mixing are to be used in this example. The process flow streams will be in cross-flow.
The given values are xf = 0.209, θ = 0.20, a* = 10, ph = 190 cm Hg, pl = 19 cm Hg, Lf = 1 × 106

cm3 (STP)/s,   = 500 × 10-10 cm3 (STP) · cm/(s · cm2 · cm Hg), and t = 2.54 × 10-3 cm. Do
as follows:

a.  Calculate y p, xo, and Am.

b.  Compare the results with Example 13.4-2.

S olu t ion: Since this is the same as Case 2, a value of xo = 0.1642 will be used for the first trial
for part (a). Substituting into Eq. (13.6-4),
Solving, θ* = 0.0992. This value of 0.0992 does not agree with the given value of θ = 0.200.
However, these values can be used later to solve Eq. (13.6-5).

For the second iteration, a value of xo = 0.142 is assumed and is used again to solve for θ* in
Eq. (13.6-4), which results in θ* = 0.1482. For the final iteration, xo = 0.1190 and θ* = θ =
0.2000. Several more values are calculated for later use and are: for xo = 0.187, θ* = 0.04876,
and for xo = 0.209, θ* = 0. These values are tabulated in Table 13.6-1.

Table 13.6-1. Calculated Values for Example 13.6-1

θ* x yp Fi

0 0.209 0.6550 0.6404


0.04876 0.1870 0.6383 0.7192

0.0992 0.1642 0.6158 0.8246


0.1482 0.1420 0.5940 0.9603

0.2000 0.1190 0.5690 1.1520

Using the material-balance equation (13.4-9) to calculate y p,
To calculate y p at θ* = 0, Eqs. (13.6-3) and (13.4-17) must be used, giving y p = 0.6550.

To solve for the area, Eq. (13.6-5) can be written as

Equation 13.6-6

where the function Fi is defined as above. Values of Fi will be calculated for different values of i in order to
integrate the equation. For θ* = 0.200, xo = 0.119, and from Eq. (13.6-4),

From Eq. (13.6-5),

Using the definition of Fi from Eq. (13.6-6),

Other values of Fi are calculated for the remaining values of θ* and are tabulated in Table 13.6-1. The
integral of Eq. (13.6-6) is obtained by using the values from Table 13.6-1 and numerically integrating Fi
versus i to give an area of 0.1082. Finally, substituting into Eq. (13.6-6),
For part (b), from Example 13.4-2, y p = 0.5067 and Am = 3.228 × 108 cm2. Hence, the cross-flow model
yields a higher y p of 0.5690, compared to 0.5067 for the complete-mixing model. Also, the area for the
cross-flow model is 10% less than for the complete-mixing model.
                             
                                                 
                                             
                                               
     

13.7. 
DERIVATION OF EQUATIONS FOR COUNTERCURRENT AND
COCURRENT FLOW FOR GAS SEPARATION FOR
MEMBRANES

13.7A. C once ntr ation G r ad ie nts in M e m b r ane s

1. Dense-p ha se memb r a ne

In gas separation using a dense-phase symmetrical polymer membrane, the solute diffuses through the
high-pressure-side gas film to the membrane surface. Then it dissolves in the membrane. At the interface
equilibrium occurs. The solute then diffuses through the solid membrane, and finally diffuses through
the gas film. The gas film resistances are quite small and can be neglected (N1). In Fig. 13.7-1a the
concentration profiles are shown. The concentration y in the flowing bulk gas phase is the same as y at
the interface of the dense polymer and depends on the flow pattern of the permeate phase.

Figure 13.7-1. Concentr ation profiles in membranes. (a) dense-phase symmetr ical membranes, (b)


asymmetr ic membrane.

2. Asy mmet r ic memb r a ne

As shown in Fig. 13.7-1b, the membrane includes a very thin, dense polymer membrane which is about
0.1 to 1 μm thick (M5, P7) and a very thick porous layer 50–200 μm thick. A typical hollow-fiber
membrane for air separation has an ID of 95 μm and an OD of 135 μm, with a wall thickness of 20 μm.

The concentration gradient in the thin dense polymer phase is similar to that for the symmetrical
membrane. However, the concentration y of component A in the bulk permeate gas phase is not the same
as y' at the surface of the thin dense polymer layer. The concentration y of the bulk gas permeate stream
depends on the flow pattern and material balances. Also, the value of y can be greater or less than y'.
The porous layer is so open that there is assumed to be little or no resistance to the flow and y' is constant
along this path. Hence, it is assumed that there is no penetration or mixing of the bulk gas phase y inside
the porous layer.

13.7B. De r iv ation of Eq u ations for  C ou nte r cu r r e nt Flow  in De nse -Phase  S ym m e tr ic


M e m b r ane s

A flow diagram for this countercurrent-flow model is given in Fig. 13.7-2, where both streams are in plug
flow. The derivation follows that given by others (B1, N1, P4, W5).

Figure 13.7-2. Flow diagram for the countercurrent-fl ow model with dense-phase symmetr ic membrane.

Making a total material balance,

Equation 13.7-1

where Lf is total feed flow rate, cm3 (STP)/s, Lo is outlet nonpermeate (reject) flow rate, cm3 (STP)/s, and

Vp is outlet permeate flow rate, cm3 (STP)/s. The rates of permeation of A and in B in a binary mixture are
similar to Eqs. (13.4-3) and (13.4-4):

Equation 13.7-2

Equation 13.7-3

where   is permeability of A, cm3 (STP) · cm/(s · cm2 · cm Hg); VA is flow rate of A in permeate, cm3
(STP)/s; Am is membrane area, cm2; ph is total pressure in the high-pressure side, cm Hg; and pt is total
pressure in low-pressure side, cm Hg.

The flux of A out of the element with area dAm is

Equation 13.7-4

The flux of B is

Equation 13.7-5

Making a total balance on the reject stream for area dAm,

Equation 13.7-6

This gives

Equation 13.7-7

Making a balance on A for area dAm,

Equation 13.7-8

Rearranging,

Equation 13.7-9

Substituting Eq. (13.7-7) into (13.7-9),

Equation 13.7-10
Making a total balance on permeate stream for area dAm,

Equation 13.7-11

This gives

Equation 13.7-12

Making a balance on A for area dAm,

Equation 13.7-13

Rearranging,

Equation 13.7-14

Substituting Eq. (13.7-12) into (13.7-14),

Equation 13.7-15

To eliminate the variables L and V, an overall balance is made for the area dAm and the reject outlet
stream:

Equation 13.7-16

Equation 13.7-17

To eliminate V, V from Eq. (13.7-16) is substituted into (13.7-17) and solved for L:

Equation 13.7-18
To eliminate L, L from Eq. (13.7-16) is substituted into (13.7-17) and solved for V:

Equation 13.7-19

Substituting Eq. (13.7-18) into (13.7-10),

Equation 13.7-20

Substituting Eqs. (13.7-4) and (13.7-5) into (13.7-20),

Equation 13.7-21

Rearranging,

Equation 13.7-22

where r = pl/ph and α* = ( /t)/( /t).

In a similar manner, substituting Eq. (13.7-19) into (13.7-15),

Equation 13.7-23

Again, substituting Eqs. (13.7-4) and (13.7-5) into (13.7-23) and rearranging,

Equation 13.7-24
Dividing Eq. (13.7-24) by (13.7-22),

Equation 13.7-25

Inverting Eq. (13.7-22),

Equation 13.7-26

13.7C . S olu tion of C ou nte r cu r r e nt Flow  Eq u ations in De nse -Phase  S ym m e tr ic M e m b r ane s

At the outlet of the residue stream of composition xo, the permeate y' and xo are related by Eq. (13.4-6),
repeated here as Eq. (13.7-27), where y p = y':

Equation 13.7-27

The solution to this quadratic equation is given as Eq. (13.4-7).

In order to solve Eqs. (13.7-25) and (13.7-26), the following procedure can be used, where xo is known or
set:

1. Using Eq. (13.7-27), the value of y' is calculated for x = xo.

2. To integrate Eq. (13.7-25), the value of (dy/dx) at x = xo must be calculated. However, this value is
indeterminate since the denominator is zero. Using L'Hopital's rule (N1, P4, R1) the numerator is
differentiated with respect to x and the denominator with respect to x and the value of y is set as y' to
give

Equation 13.7-28

[View full size image]
3. Starting at the residual end at xo, Eq. (13.7-25) is integrated numerically to give the y-versus-x
relationship and y p (P4, R1).

4 . The relationship of y versus x is substituted into Eq. (13.7-26), which is integrated from xf to xo to
obtain the area Am.

5. Substituting into the material-balance Eqs. (13.4-8) and (13.4-2), the cut or fraction of feed
permeated, θ, is calculated (N1, Rl, W5).

6 . If θ is set and xo is unknown, the solution is trial and error. The value of xo is assumed and the
integration of Eq. (13.7-25) is performed to obtain y p. Then xo is calculated from Eq. (13.4-9). This is
repeated until the assumed and calculated values of xo agree.

13.7D. De r iv ation of Eq u ations for  C ou nte r cu r r e nt Flow  in Asym m e tr ic M e m b r ane s

The flow diagram for this countercurrent-flow model is shown in Fig. 13.7-3, where both streams are in
plug flow. The permeate y' leaving the membrane differs from the symmetric-membrane case and is not
the same as the bulk phase concentration y at this point. This is also shown in Fig. 13.7-1b.

Figure 13.7-3. Flow diagram for countercurrent flow with asymmetr ic membrane.

The flux of A out of the element with area dAm is

Equation 13.7-29
where y' is given by Eq. (13.7-30), which is similar to Eqs. (13.7-27) and (13.4-6):

Equation 13.7-30

The flux of B is

Equation 13.7-31

Equations (13.7-29) and (13.7-31) differ from Eqs. (13.7-4) and (13.7-5) for the symmetric membrane in
that y' is used instead of y in the terms for concentration difference.

The rest of the derivation is identical to that for the dense-phase symmetric membrane (N1, R1). The final
equations are

Equation 13.7-32

Equation 13.7-33

Inverting Eq. (13.7-32),

Equation 13.7-34

Equations (13.7-27) for y' and (13.7-28) for (dy/dx) at x = xo for symmetric membranes are also
applicable here for asymmetric membranes. The method of solution for the above equations is similar to
that for symmetric membranes.

13.7E. De r iv ation of Eq u ations for  C ocu r r e nt Flow  in Asym m e tr ic M e m b r ane s

For cocurrent flow, the cocurrent model is shown in Fig. 13.7-4. The derivation uses Eqs. (13.7-29)-(13.7-
31) as before. Proceeding in a manner similar to the countercurrent case, the final equations are (N1, P4,
R1):

Equation 13.7-35

Equation 13.7-36

Figure 13.7-4. Flow diagram for cocurrent flow with asymmetr ic membrane.

The method of solution is similar to that for countercurrent flow. Integration of Eq. (13.7-35) is started at
the feed inlet, where y' is determined by using xf instead of xo in Eq. (13.7-27). Then, using Eq. (13.7-28)
with xf instead of xo, (dy/dx) at x = xf is calculated. This is then used to integrate Eq. (13.7-35) starting
at the feed end, where x = xf. Finally, Eq. (13.7-36) is integrated to obtain Am.

13.7F. Effe cts of Pr oce ssing Var iab le s on G as S e p ar ation

1. Effect s of p r essu r e r a t io a nd  sep a r a t ion fa ct or  on r ecov er y

Using the Weller-Steiner Eq. (13.4-6) for the complete-mixing model, the effects of pressure ratio, ph/pl,
and separation factor, α*, on permeate purity can be determined for a fixed feed composition. Figure
13.7-5 is a plot of this equation for a feed concentration of 30% (S7). For symmetric and asymmetric
membranes, this equation can be expected to provide estimates of product purity and trends for
conditions of low to modest recovery in all types of models, including complete-mixing, cross-flow, and
countercurrent.

Figure 13.7-5. Effe cts  of separation factor and pressure ratio on permeate purity . (Feed x f = 0.30.) [From

" Membranes Separate Gases Selectively,"  by D. J. Stookey, C. J. Patto n, and G. L. Malcolm, Chem. Eng.


Progr., 82(11), 36(1986). Reproduced by permission of the American Institute of Chemical Engineers.]
Figure 13.7-5 shows that above an a* of 20, the product purity is not greatly affected. Also, above a
pressure ratio of about 6, this ratio has a diminishing effect on product purity.

If liquids are present in the gas separation process, a liquid film can increase the membrane resistance
markedly. Liquids can also damage the membrane by chemical action or by swelling or softening. If water
vapor is present in the gas streams, the dew point may be reached in the residue product and liquid may
condense. Condensation of hydrocarbons must also be avoided.

2. Effect s of p r ocess flow  p a t t er ns on sep a r a t ion in sy mmet r ic memb r a nes

Detailed parametric studies have been done by various investigators (P4, P5, W5) for binary systems.
They compared the four flow patterns of complete mixing, cross-flow, cocurrent, and countercurrent
flow. In Fig. 13.7-6 (W5) the permeate concentration is shown plotted versus stage cut, θ, for a feed of air
(xf = 0.209 for oxygen) with α* = 10 and ph/pl = 5. It is shown that, as expected, the countercurrent flow
pattern gives the best separation. The other patterns—cross-flow, cocurrent, and complete mixing—give
lower separations in descending order. Note that when the stage cut θ = 0, all flow patterns are
equivalent to the complete mixing model and give the same permeate composition. Also, at θ = 1.00, all
patterns again give the same value of y p = 0.209, which is also the feed composition.

Figure 13.7-6. Effe ct of flow patte rn in symmetr ic membranes. Operating conditions for air are as follows: x f =

0.209,   = 10, ph /pl  = 380 cm Hg/76 cm Hg = 5.   = 500 × 10-10  cm 3  (STP) · cm/s · cm 2  · cm Hg. (1)


countercurrent flow, (2) cross-flow, (3) cocurrent flow, (4) complete mixing (W5). [Reprinted fr om W. P.
Walawender and S. A. Stern, Sep. Sci., 7, 553 (1972). By courtesy of Marcel Dekker, Inc.]
The required membrane areas for the same process conditions and air feed versus stage cut were also
determined (W5). The areas for all four types of flow pattern were shown to be within about 10% of each
other. The countercurrent and cross-flow patterns give the lowest area required.

3. Effect s of p r ocess flow  p a t t er ns on sep a r a t ion in a sy mmet r ic memb r a nes

Calculations using the mathematical models for asymmetric membranes give virtually identical
performances for cocurrent and countercurrent flow (G1, P2, P6). The porous support prevents mixing of
the bulk permeate concentration and the skin surface concentration y' as shown in Fig. 13.7-1b. Hence,
the direction of the bulk flow permeate stream has no effect. Experimental tests using helium recovery
from natural gas (P2, P6), nitrogen recovery from air (G1), and helium from nitrogen (G1) show that the
experimental data and the model predictions agree quite well.

4 . Effect  of p r essu r e d r op  on sep a r a t ions in a sy mmet r ic memb r a nes

In hollow-fiber membranes (N1), an appreciable pressure drop can occur for flow inside long tubes or for
tubes with very small inside diameters. In the shell side the pressure drop is generally very small and is
neglected. Pressure drop in the tubes is always detrimental to the separation. For feed inside the tubes,
the actual average feed pressure will be less than the inlet feed pressure. If the permeate flow is inside the
tubes, then the actual average permeate pressure will be higher than the permeate outlet pressure. In
both of these cases, the driving force for permeation is reduced and less separation occurs.

To reduce these pressure effects, where the stage cut θ is small, giving a low permeate flow rate, it is
preferable to have the large feed flow rate in the shell, where the pressure drop is small. For a high stage
cut, the feed should be inside the tubes, where most of the feed permeates into the shell.

Using the model equations, the pressure drop inside the tubes can be accounted for by using the Hagen-
Poisseuille equation (2.10-2) for laminar flow:

Equation 2.10-2
where z2 - z1 is total length. Writing this for a differential length dz cm and a dph in Pascals,

Equation 13.7-37

Converting the feed flow rate L cm3/s at Ts and ps (STP) to the actual velocity ν at T and ph,

Equation 13.7-38

where NT is the number of tubes in parallel. The average viscosity μ can be approximated by using the
average mole fraction of the feed and the residual outlet. The average μ is then the sum of the mole
fractions of each component times the viscosity of the pure gases. The final equation is (G1, N1, P2)

Equation 13.7-39

The area Am can be related to z by dAm = πDNT dz. This then relates dAm to dph. In integrating the
model equations, a constant (uniform) ph is first assumed (G1, P2, P7). This gives the relation between y
and x and Am. Then, using the material-balance equation (13.7-18) between L and y and x, equation
(13.7-39) is used to generate a new pressure profile. This process is then repeated.
                             
                                                 
                                             
                                               
     

13.8. DERIVATION OF FINITE­DIFFERENCE NUMERICAL METHOD
FOR ASYMMETRIC MEMBRANES

13.8A. C ou nte r cu r r e nt Flow

The flow diagram for the numerical method is shown in Fig. 13.8-1. Using the method derived by McCabe
et al. (M5) and taking an area ΔAm, the mass balances on both streams can be written as

Equation 13.8-1

Figure 13.8-1. Flow diagram for countercurrent flow with asymmetr ic membrane using finite diffe rence


method.

[View full size image]

The value of   can be calculated from Eq. (13.7-27) using xin  for x and   for y'. Also,   can be


calculated similarly from xout. Then, writing a balance on A,

Equation 13.8-2

where  . Substituting Lout from Eq. (13.8-1) into (13.8-2),

Equation 13.8-3
Equations (13.7-27), (13.8-2), and (13.8-3) can be solved numerically starting at the feed xf = xin  to

determine the permeate ΔV and   for each ΔAm and increments of x to xo at the outlet reject. Usually
10 or so increments of x from xf to xo are sufficient.

Then, to obtain the values of V and the bulk composition y as a function of x, the calculation is started at
xo. Using Equations (13.8-4) and (13.8-5), the increments of ΔV are added to get V, and y is calculated
for each ΔAm increment up to xf at the feed inlet:

Equation 13.8-4

Equation 13.8-5

For cocurrent or parallel flow, the only difference is in calculating V. Starting at xf inlet and using Eqs.
(13.8-4) and (13.8-5), the increments of ΔV are added to get V up to xo.

To calculate the area for countercurrent or cocurrent flow, rewriting Eq. (13.7-4),

Equation 13.8-6

where r = pt/ph. The average driving force is

Equation 13.8-7

Solving for ΔAm,

Equation 13.8-8
Starting at xf, ΔAm is calculated for each increment to obtain Σ ΔλAm versus x.

13.8B. S hor t-C u t Nu m e r ical M e thod

Making an approximate material balance to obtain a   or y p for the total area from   to   (M5),

Equation 13.8-9

An overall and component material balance gives

Equation 13.8-10

Equation 13.8-11

Substituting Eq. (13.8-10) into (13.8-11),

Equation 13.8-12

Equation (13.8-12) can be solved for Vp and (13.8-10) solved for Lo.

To calculate the approximate area for countercurrent or cocurrent flow, Eq. (13.8-8) is rewritten for the
total area Am:

Equation 13.8-13
where (x - ry')lm is the ln mean of (xf -  ) and (xo -  ). Since plots of x and y' versus Am are
approximately straight lines, this approximate area is within about 15% of the Am calculated by the
finite-difference method.

EXAMPLE 13.8­1. Air Separation Using an Asymmetric
Membrane for Countercurrent Flow
It is desired to design a hollow-fiber asymmetric membrane for air separation to produce a
residue which contains 97.0% N2 using countercurrent flow. The dense polymer layer is in the
inside of the tubes and the feed is in the tubes. Experimental values for commercial
membranes give separation factors α* of O2/N2 between 3 and 7 (H2) with a typical value of

5.0 (G1). Permeance values of  /t are given (H2) of 5 × 10-6 to 250 × 10-6 cm3 (STP)/(s · cm2
· cm Hg) with a typical value of 20 × 10-6 (G1). The typical values will be used. The feed or tube
side pressure is 1034 kPa abs and the shell side or permeate is 103.4 kPa. The feed rate of air is
10.0 m3 (STP)/h.

a.  Using the finite-difference method, calculate the permeate composition, the fraction θ
of feed permeated, and the residue and permeate flows. Assume negligible pressure
drop in the tubes. Calculate the composition y of the permeate as a function of the
residue composition x.

b.  Calculate the membrane area needed.

c.  Using the short-cut procedure, calculate the permeate composition, θ, flows, and
membrane area.

d.  Repeat (a) for cocurrent flow. Plot x, y, and y' for countercurrent and cocurrent flow
versus area.

S olu t ion: For part (a), Lf = 10.0 m3 (STP)/h, xf = 0.209, xo = 0.03, ph = 1034 kPa, pl = 103.4

kPa,  /t = 20 × 10-6 cm3 (STP)/(s · cm2 · cm Hg), α* = 5.0. Using Table 13.3-1,

Starting at the feed inlet (Fig. 13.8-2), where xf = 0.209, using an area ΔAm, going from xf = x1
= 0.209 to x2 = 0.190, and using Eq. (13.7-27) to calculate y',

Equation 13.7-27
Figure 13.8-2. Finite-diffe rence elements  for countercurrent flow in Example 13 8-1.

[View full size image]

The solution to this is given by the quadratic equation (13.4-7):

Equation 13.4-7

where a = 1 - α*, b = -1 + α* + 1/r + x/r(α* - 1), and c = -α*x/r. Substituting and solving for 
where x1 = 0.209,
Again, for x2 = 0.190,   = 0.4830 is obtained from Eq. (13.7-27).

Then,   = (0.5148 + 0.4830)/2 = 0.4989. Substituting into Eq. (13.8-
3),

Then by Eq. (13.8-1),

For the second increment for ΔAm2 in Fig. 13.8-2, solving for   with x3 = 0.170,

Using Eq. (13.4-7),   = 0.4471. Then   = (0.4830 + 0.4471)/2 = 0.4651

Also,

This is continued, and for the eighth increment, x8 = 0.07, x9 = 0.050,   = 0.2198,   =

0.1629,   = 0.1914, ΔV8 = 0.7757, and L9 = 4.7088. For the final or ninth increment, x10 =
xo = 0.030, x9 = 0.050,   = 0.1629,   = 0.1014,   = 0.1322, ΔV9 = 0.9215, and L10 = Lo =

3.7873 m3/h. The permeate flow rate Vp = Lf - Lo = 10.00 - 3.7873 = 6.2127 m3/h. The stage
cut θ = 6.2127/10.00 = 0.6213.

To calculate the bulk composition y as a function of x for countercurrent flow, it is necessary to
start at xo. Using Eq. (13.8-4),

For calculation of y 9 using Eq. (13.8-5),

For the eighth plus ninth increments,

This calculation is continued up to the feed entrance. Values of y, x, and y' are given in Table
13.8-1.

Table 13.8-1. Compositions and Areas for Numerical Method in Example 13.8-1

Counter and A, Area
X Countercurrent y Cocurrent y Cocurrent y' ΔA, Area (m 2 ) (m 2 )

0.209 0.3181 0.5148 0.5148 0.000 0.000


0.190 0.2983 0.4989 0.4830 3.674 3.674

0.170 0.2769 0.4817 0.4471 3.968 7.642


0.150 0.2549 0.4637 0.4084 4.117 11.759

0.130 0.2323 0.4446 0.3665 4.323 16.082

0.110 0.2090 0.4242 0.3214 4.607 20.689


0.090 0.1847 0.4021 0.2726 5.006 25.695
0.070 0.1593 0.3779 0.2198 5.592 31.287

0.050 0.1322 0.3505 0.1629 6.508 37.795


0.030 0.1014 0.3181 0.1014 8.144 45.939
To calculate y as a function of x for cocurrent flow, it is necessary to start at xf. For the first
increment, from Eq. (13.8-4),

For the second increment,

This calculation is continued up to the outlet at xo.

For part (b), Eq. (13.8-8) is used starting at xf for both countercurrent and cocurrent flows. For

the first increment, the flow rates in m3/h are converted to m3/s by multiplying by (1/3600).

Also, xf = 0.209, x2 = 0.190,   = 0.5148,   = 0.4830,   = 0.4989, ΔV1 = 0.6151 m3/h,


and ph = 1034 kPa. Calculating x - ry' at points 1 and 2 and the average (x − ry') from Eq.
(13.8-7),

Using Eq. (13.8-8),

For the second increment, x3 = 0.170,   = 0.4471,   = 0.4651, and ΔV2 = 0.6360. Then,


This is continued, and the results are given in Table 13.8-1. The final total area is 45.94 m2.

For part (c), using the shortcut procedure, Eq. (13.8-9) gives the value of y p:

This value of 0.3081 compares to 0.3181 for the numerical method. Making a component
balance in Eq. (13.8-12),

Solving, Vp = 6.437 and Lo = (10.00 - 6.437) = 3.563. This gives a stage cut θ = 6.437/10.00 =
0.6437, as compared with 0.6213 for the numerical method. To calculate the area, the driving
forces are

The area from Eq. (13.8-13) is

This value of 53.43 is about 16% greater than the numerical method. A plot of these data for
the numerical method is given in Fig. 13.8-3.

Figure 13.8-3. Plot of composition versus area for numerical method in Example 13.8-1.
13.8C . Use  of S p r e ad she e t for  Finite -Diffe r e nce  Nu m e r ical M e thod

The numerical method can easily be adapted so that a spreadsheet can be used to solve the problem for
asymmetric membranes. Using Excel® or other programs, basic formulas can be entered into cells.

Output data from a spreadsheet are given in Table 13.8-2 for Example 13.8-1. Input data for the
calculations are briefly as follows: In cells D3-D10 known values are entered. In cell D11 the equation for r
= pl/ph is given by the formula $D$8/$D$7.

Table 13.8-2. Output fr om Spreadsheet for Finite-Diffe rence Method for Example 13.8-1

Col/
Row A B C D E F G H I J K

1 Example                    
13.8-1

2                      
3 Input                    
Variables:
4 Lf (feed     10 m**3 (STP)/hr            
rate)

5 xf (O2  mole     0.209              


fraction—
feed)

6 xo  (O2     0.03              
mole
fraction—
outlet)
7 Pressure     1034 kPa            
(feed), ph
8 Pressure     103.4 kPa            
(permeate),
pl

9     1.50E- m**3 (STP)/            


/t 10

10 α*(O2 /N2     5 s · m**2  · Pa            


separation
factor)
11 r = pl/ph     0.1              

12                      
13 I 1 2 3 4 5 6 7 8 9 10

14 x(I) 0.2090 0.1900 0.17 0.15 0.13 0.11 0.09 0.07 0.05 0.03
15 A -4.0000 -4.0000 -4.0000 -4.0000 -4.0000 -4.0000 -4.0000 -4.0000 -4.0000 -4.0000

16 B 22.3600 21.6000 20.8000 20.0000 19.2000 18.4000 17.6000 16.8000 16.0000 15.2000

17 c -10.4500 -9.5000 -8.5000 -7.5000 -6.5000 -5.5000 -4.5000 -3.5000 -2.5000 -1.5000
18 y'(I) 0.5148 0.4830 0.4471 0.4083 0.3665 0.3214 0.2726 0.2198 0.1629 0.1014
19 y(avg)   0.4989 0.4651 0.4277 0.3874 0.3439 0.2970 0.2462 0.1914 0.1321

20 ΔV   0.6151 0.6361 0.6300 0.6307 0.6401 0.6617 0.7022 0.7759 0.9219


21 L(I) 10.0000 9.3849 8.7487 8.1187 7.4880 6.8478 6.1861 5.4839 4.7081 3.7862

22                      

23 I   1 2 3 4 5 6 7 8 9

24 V(counter) 6.2138 6.2138 5.5987 4.9626 4.3326 3.7018 3.0617 2.4000 1.6978 0.9219

25 yavg *ΔV 1.9764 1.9764 1.6695 1.3737 1.1042 0.8599 0.6397 0.4432 0.2703 0.1218

26 y(I) 0.3181 0.3181 0.2982 0.2768 0.2549 0.2323 0.2089 0.1847 0.1592 0.1321

27                      

28 Checks:                    

29 Mass(in) 10.0000                  
30 Mass(out) 10.0000                  

31 [O2 ]in 2.0900                  

32 [O2 ]out 2.0900                  

33                      

34 I   1 2 3 4 5 6 7 8 9
35 V(cocurr)   0.6151 1.2513 1.8813 2.5120 3.1522 3.8139 4.5161 5.2919 6.2138
36 yavg*ΔV   0.3069 0.6027 0.8722 1.1166 1.3367 1.5333 1.7061 1.8546 1.9764

37 y(I)   0.4989 0.4817 0.4636 0.4445 0.4241 0.4020 0.3778 0.3505 0.3181
38                      

39 Calculate                    
the Areas
for each
increment:
40                      

41 (x ­ ry')avg 0.1496 0.1335 0.1172 0.1013 0.0856 0.0703 0.0554 0.0409 0.0268 0.0099
42 ( )* 0.5584                  
/t ph

43 ΔA 3.6735 3.9690 4.1170 4.3223 4.6063 5.0061 5.5907 6.5072 8.1449  

44 Total Area 45.9370                  

Row 13 is used to keep track of the indexes used in this part of the calculation. Row 14 gives the input
values of x1, x2, and so on. In rows 15–18 the values of a, b, c, and y' are calculated using Eqs. (13.4-7)
and (13.7-27). For example, in cell B18 the formula entered is =(-B16+SQRT(B16*B16-

4*B15*B17))/2*B15). In row 19,  . In row 20, ΔV is calculated from Eq. (13.8-3).
The formula in cell C20 is =B21*(B14-C14)/ (C19-C14) and in D20 is =C21*(C14-D14)/(D19-D14). In row
21, L is calculated from Eq. (13.8-1), where L2 = L1 - ΔV1 by using the formula in cell C21, which is = -
(C20-B21), for C22, =-(D20-B21), and so on.

Row 23 is a new set of indexes for countercurrent flow. To calculate V in row 24 using Eq. (13.8-4), where
V = ∑ ΔV, and starting at the outlet xo, the formula in cell K24 is =K20, in J24, = J20+K24, and so on.

For row 25, to calculate ∑   ΔV, the formula in cell K25 is =K19*K20, in J25, J19*J20+K25, and so on.

For the bulk permeate composition, y is calculated in row 26 from Eq. (13.8-5), where y= ∑   ΔV/V. In
cell B26, the formula is =B25/B24.

Rows 28-32 are optional and are used to check the mass balances for the inlet and outlet streams. In cell
B29, the mass in is =$D$4; the mass out in B30 is =B24+K21. Similarly, cell B31 is =$D$4*$D$5 and
B32 is =B24*B26+K21*K14.

For cocurrent flow, starting at xf, Eq. (13.8-4), where V = ∑ ΔV, is calculated in row 35. In row 36, ∑ 
ΔV is calculated using the formula in cell C36 of =19*C20, in D36, =D19*D20+C36, and so on. Then Eq.

(13.8-5) is used to calculate the bulk composition y from ∑   ΔV/V in row 37.

To calculate the areas, in row 41 (x - ry')av  is calculated for each increment, using Eq. (13.8-7). The

formula in cell B41 is =((B14-$D$11*B18) + (C14-$D$11*C18))/2. In cell B42 the conversion of V m3/h to
m3/s and kPa to Pa is performed using = ($D$9*$D$7*1000*3600). In row 43, using Eq. (13.8-8) to
calculate ΔAm, the formula in cell B43 is C19*C20/($B$42*B41). In row 44 all of the ΔAm values in row
43 are added to get the total Am using =SUM(B43:J43).

13.8D. C alcu lation of Pr e ssu r e -Dr op  Effe cts on Pe r m e ation

1. Est ima t ion of nu mb er  of t u b es a nd  leng t h

In order to calculate the pressure drop inside the hollow-fiber tubes, the dimensions, number of tubes,
and area Am of the membrane must be known. The following procedure can be employed. The shortcut
procedure is first used with Eqs. (13.8-9)-(13.8-13). This gives Lf, Lo, Vp,  , and Am. Then the average
flow rate in the tubes is calculated from the equation Lav  = (Lf + Lo)/2.

The number of tubes in parallel NT must be estimated from typical laboratory or commercial data. For

example, for air with a flow rate of 3 m3/h, 3.8 × 104 fibers (NT) are used with an ID of 95 μm, and a

length (z2 - z1) of 48.26 cm. For a flow rate Lf of 10.0 m3/hr in Example 13.8-1 and to keep a similar and
reasonable velocity in the tubes, the NT needed will be directly proportional to the inlet Lf. Then, knowing
the Am, an estimated total length (z2 - z1) of the tubes can be calculated from Eq. (13.8-14):

Equation 13.8-14

2. Finit e-d iffer ence met ho d  t o inclu d e effect  of p r essu r e d r op

For the finite-difference numerical method, Eq. (13.8-14) can be rewritten as

Equation 13.8-15

Also, Eq. (13.7-38) can be rewritten for a finite increment of Δz length:

Equation 13.8-16

The following steps, which may require several iterations, can be used in the finite-difference numerical
method to include the effect of pressure drop in the tubes:

1. For the first increment shown in Fig. 13.8-2, a constant inlet pressure ph1 (ph) is used for phav  to

calculate   and  , ΔV1, L2, and ΔAm1 from Eqs. (13.7-27), (13.8-1), (13.8-3), (13.8-7), and (13.8-


8).

2. The value of NT is obtained from typical data as discussed above in Subsection 1. Using Eq. (13.8-15),
the incremental length Δz is obtained.

3. Using Lav  = (L1 + L2)/2 and the inlet ph1 for ph av , the Δph for the first increment is calculated from


Eq. (13.8-16).
4 . For the second iteration, the new ph av  to use is calculated from ph av  = ph1 - Δph/2. A new value of

the outlet ph2 = ph1 - Δph is used to recalculate a new   from Eq. (13.7-27). The value of   remains


the same. Then by repeating steps 1 through 4, a new value of Δph is obtained. Usually only three or
so iterations are needed to obtain a constant value of Δph, phav , and ΔAm1. Using a spreadsheet as in
Ex. 13.8-1, this procedure can be repeated for each finite section.

3. Det er mina t ion of effect  of p r essu r e d r op  u sing  sho r t cu t  met ho d

The values of Lav , NT, Am, and overall length (z2 - z1) are obtained from the shortcut calculation in
Subsection 1 above. The shortcut value of the overall pressure drop (ph - pho) can be obtained from Eq.
(13.8-16) using ph at the inlet as ph av  and the overall length (z2 - z1). Then for a second and final
iteration, the new and corrected pressures ph av  = ph - Δph/2 and pho = ph - Δph are used in Eqs. (13.7-27)

and (13.8-9)-(13.8-13) to recalculate  ,  , Vp, and Am again. This recalculated Am will include an
approximate effect of pressure drop in the tubes.
                             
                                                 
                                             
                                               
     

13.9. REVERSE­OSMOSIS MEMBRANE PROCESSES

13.9 A. Intr od u ction

1. Int r od u ct ion

To be useful for separation of different species, a membrane must allow passage of certain molecules and
exclude or greatly restrict passage of others. In osmosis, a spontaneous transport of solvent occurs from a
dilute solute or salt solution to a concentrated solute or salt solution across a semipermeable membrane
which allows passage of the solvent but impedes passage of the salt solutes. In Fig. 13.9-1a, the solvent
water normally flows through the semipermeable membrane to the salt solution. The levels of both
liquids are the same as shown. The solvent flow can be reduced by exerting a pressure on the salt-solution
side and membrane, as shown in Fig. 13.9-1b, until at a certain pressure, called the osmotic pressure π of
the salt solution, equilibrium is reached and the amount of the solvent passing in opposite directions is
equal. The chemical potentials of the solvent on both sides of the membrane are equal. The properties of
the solution determine only the value of the osmotic pressure, not the membrane, provided that it is truly
semipermeable. To reverse the flow of the water so that it flows from the salt solution to the fresh solvent,
as in Fig. 13.9-1c, the pressure is increased above the osmotic pressure on the solution side.

Figure 13.9-1. Osmosis and reverse osmosis: (a) osmosis, (b) osmotic equilibrium, (c) reverse osmosis.

This phenomenon, called reverse osmosis, is used in a number of processes. An important commercial
use is in the desalination of seawater or brackish water to produce fresh water. Unlike distillation and
freezing processes used to remove solvents, reverse osmosis can operate at ambient temperature without
phase change. This process is quite useful for the processing of thermally and chemically unstable
products. Applications include concentration of fruit juices and milk, recovery of protein and sugar from
cheese whey, and concentration of enzymes.
2. Osmot ic p r essu r e of solu t ions

Experimental data show that the osmotic pressure π of a solution is proportional to the concentration of
the solute and temperature T. Van't Hoff originally showed that the relationship is similar to that for
pressure of an ideal gas. For example, for dilute water solutions,

Equation 13.9-1

where n is the number of kg mol of solute, Vm the volume of pure solvent water in m3 associated with n

kg mol of solute, R the gas law constant 82.057 × 10-3 m3 · atm/kg mol · K, and T is temperature in K. If a
solute exists as two or more ions in solution, n represents the total number of ions. For more
concentrated solutions, Eq. (13.9-1) is modified using the osmotic coefficient ϕ, which is the ratio of the
actual osmotic pressure π to the ideal π calculated from the equation. For very dilute solutions, ϕ has a
value of unity and usually decreases as concentration increases. In Table 13.9-1 some experimental
values of π are given for NaCl solutions, sucrose solutions, and seawater solutions (S3, S5).

Table 13.9-1. Osmotic Pressure of Various Aqueous Solutions at 25°C (P1, S3, S5)

Sodium Chloride Solutions Sea Salt Solutions Sucrose Solutions

Osmotic Osmotic Osmotic


Density Pressure Wt % Pressure Solute Mol. Pressure
(kg/m 3 ) (atm ) Salts (atm ) Frac. × 103 (atm )

0 997.0 0 0 0 0 0

0.01 997.4 0.47 1.00 7.10 1.798 2.48


0.10 1001.1 4.56 3.45[*] 25.02 5.375 7.48

0.50 1017.2 22.55 7.50 58.43 10.69 15.31

1.00 1036.2 45.80 10.00 82.12 17.70 26.33

2.00 1072.3 96.2        

[*]
 Value for standard seawater.

EXAMPLE 13.9­1. Calculation of Osmotic Pressure of Salt
Solution
Calculate the osmotic pressure of a solution containing 0.10 g mol NaCl/1000 g H2O at 25°C.

S olu t ion: From Table A.2-3, the density of water = 997.0 kg/m3. Then, n = 2 × 0.10 × 10-3 =
2.00 × 10-4 kg mol (NaCl gives two ions). Also, the volume of the pure solvent water Vm = 1.00

kg/(997.0 kg/m3). Substituting into Eq. (13.9-1),
This compares with the experimental value in Table 13.9-1 of 4.56 atm.

3. Ty p es of memb r a nes for  r ev er se osmosis

One of the more important membranes for reverse-osmosis desalination and many other reverse-osmosis
processes is the cellulose acetate membrane. The asymmetric membrane is made as a composite film in
which a thin, dense layer about 0.1–10 μm thick of extremely fine pores is supported upon a much
thicker (50–125 μm) layer of microporous sponge with little resistance to permeation. The thin, dense
layer has the ability to block the passage of quite small solute molecules. In desalination the membrane
rejects the salt solute and allows the solvent water to pass through. Solutes which are most effectively
excluded by the cellulose acetate membrane are the salts NaCl, NaBr, CaCl2, and Na2SO4; sucrose; and
tetralkyl ammonium salts. The main limitations of the cellulose acetate membrane are that for the most
part it can only be used in aqueous solutions and that it must be used below about 60°C.

Another important membrane useful for seawater, wastewater, nickel-plating rinse solutions, and other
solutes is the synthetic aromatic polyamide membrane "Permasep," made in the form of very fine, hollow
fibers (L1, P3). When used industrially this type of membrane withstands continued operation at pH
values of 10 to 11 (S4). Many other anisotropic membranes have also been synthesized from synthetic
polymers, some of which can be used in organic solvents, at higher temperatures, and at high or low pH
(M2, Rl).

13.9 B. Flu x Eq u ations for  R e v e r se  Osm osis

1. Ba sic mod els for  memb r a ne p r ocesses

There are two basic types of mass-transport mechanisms which can take place in membranes. In the first

basic type, using tight membranes, which are capable of retaining solutes of about 10   in size or less,
diffusion-type transport mainly occurs. Both the solute and the solvent migrate by molecular or Fickian
diffusion in the polymer, driven by concentration gradients set up in the membrane by the applied
pressure difference. In the second basic type, using loose, microporous membranes which retain particles

larger than 10  , a sieve-type mechanism occurs, where the solvent moves through the micropores in
essentially viscous flow and the solute molecules small enough to pass through the pores are carried by
convection with the solvent. For details of this second type of mechanism, see (M2, W1).

2. Diffu sion-t y p e mod el

For diffusion-type membranes, the steady-state equations governing the transport of solvent and solute
are to a first approximation as follows (M2, M3). For the diffusion of the solvent through the membrane,
as shown in Fig. 13.9-2,

Equation 13.9-2
Equation 13.9-3

Figure 13.9-2. Concentr ations and fluxes in reverse-osmosis process.

where Nw  is the solvent (water) flux in kg/s · m2; Pw  the solvent membrane permeability, kg solvent/s · m

· atm; Lm the membrane thickness, m; Aw  the solvent permeability constant, kg solvent/s · m2 · atm; ΔP
= P1 - P2 (hydrostatic pressure difference with P1 pressure exerted on feed and P2 on product solution),
atm; and Δπ = π1 - π2 (osmotic pressure of feed solution — osmotic pressure of product solution), atm.
Note that subscript 1 is the feed or upstream side of the membrane and 2 the product or downstream side
of the membrane.

For the diffusion of the solute through the membrane, an approximation for the flux of the solute is (Cl,
Ml)

Equation 13.9-4

Equation 13.9-5

where Ns is the solute (salt) flux in kg solute/s · m2; Ds the diffusivity of solute in membrane, m2/s; Ks =
cm/c (distribution coefficient), concentration of solute in membrane/concentration of solute in solution;
As is the solute permeability constant, m/s; c1 the solute concentration in upstream or feed (concentrate)

solution, kg solute/m3; and c2 the solute concentration in downstream or product (permeate) solution,

kg solute/m3. The distribution coefficient Ks is approximately constant over the membrane.

Making a material balance at steady state for the solute, the solute diffusing through the membrane must
equal the amount of solute leaving in the downstream or product (permeate) solution:

Equation 13.9-6

where cw2 is the concentration of solvent in stream 2 (permeate), kg solvent/m3. If the stream 2 is dilute
in solute, cw2 is approximately the density of the solvent. In reverse osmosis, the solute rejection R is
defined as the ratio concentration difference across the membrane divided by the bulk concentration on
the feed or concentrate side (fraction of solute remaining in the feed stream):

Equation 13.9-7

This can be related to the flux equations as follows, by first substituting Eqs. (13.9-2) and (13.9-4) into
(13.9-6) to eliminate Nw  and Ns in Eq. (13.9-6). Then, solving for c2/c1 and substituting this result into
Eq. (13.9-7),

Equation 13.9-8

Equation 13.9-9

where B is in atm-1. Note that B is composed of the various physical properties Pw , Ds, and Ks of the
membrane and must be determined experimentally for each membrane. Usually it is the product DsKs
that is determined, not the values of Ds and Ks separately. Also, many of the data reported in the

literature give values of (Pw /Lm) or Aw  in kg solvent/s · m2 · atm and (DsKs/Lm) or As in m/s and not


separate values of Lm, Pw , and so on.
EXAMPLE 13.9­2. Experimental Determination of
Membrane Permeability
Experiments at 25°C were performed to determine the permeabilities of a cellulose acetate
membrane (A1, W1). The laboratory test section shown in Fig. 13.9-3 has membrane area A =
2.00 × 10-3 m2. The inlet feed solution concentration of NaCl is c1 = 10.0 kg NaCl/m3 solution

(10.0 g NaCl/L, ρ1 = 1004 kg solution/m3). The water recovery is assumed low so that the
concentration c1 in the entering feed solution flowing past the membrane and the
concentration of the exit feed solution are essentially equal. The product solution contains c2 =

0.39 kg NaCl/m3 solution (ρ2 = 997 kg solution/m3) and its measured flow rate is 1.92 × 10-8

m3 solution/s. A pressure differential of 5514 kPa (54.42 atm) is used. Calculate the
permeability constants of the membrane and the solute rejection R.

Figure 13.9-3. Process flow diagram of experimental reverse-osmosis laboratory unit.

S olu t ion: Since c2 is very low (dilute solution), the value of cw2 can be assumed as the density

of water (Table 13.9-1), or cw2 = 997 kg solvent/m3. To convert the product flow rate to water

flux, Nw , using an area of 2.00 × 10-3 m2,

Substituting into Eq. (13.9-6),

To determine the osmotic pressures from Table 13.9-1, the concentrations are converted as
follows. For c1, 10 kg NaCl is in 1004 kg solution/m3 (ρ1 = 1004). Then, 1004 - 10 = 994 kg

H2O in 1 m3 solution. Hence, in the feed solution, where the molecular weight of NaCl = 58.45,
(10.00 × 1000)/ (994 × 58.45) = 0.1721 g mol NaCl/kg H2O. From Table 13.9-1, π1 = 7.80 atm
by linear interpolation. Substituting into Eq. (13.9-1), the predicted π1 = 8.39 atm, which is
higher than the experimental value. For the product solution, 997 - 0.39 = 996.6 kg H2O.
Hence, (0.39 × 1000)/(996.6 × 58.45) = 0.00670 g mol NaCl/kg H2O. From Table 13.9-1, π2
= 0.32 atm. Then, Δπ = π1 - π2 = 7.80 - 0.32 = 7.48 atm and ΔP = 54.42 atm.

Substituting into Eq. (13.9-2),

Solving, (Pw /Lm) = Aw  = 2.039 × 10-4 kg solvent/s · m2 · atm. Substituting into Eq. (13.9-4),

Solving, (DsKs/Lm) = As = 3.896 × 10-7  m/s.

To calculate the solute rejection R by substituting into Eq. (13.9-7),

Also, substituting into Eq. (13.9-9) and then Eq. (13.9-8),
                             
                                                 
                                             
                                               
     

13.10. APPLICATIONS, EQUIPMENT, AND MODELS FOR REVERSE
OSMOSIS

13.10A. Effe cts of Op e r ating Var iab le s

In many commercial units, operating pressures in reverse osmosis range from about 1035 up to 10350
kPa (150 up to 1500 psi). Comparison of Eq. (13.9-2) for solvent flux with Eq. (13.9-4) for solute flux
shows that the solvent flux Nw  depends only on the net pressure difference, while the solute flux Ns
depends only on the concentration difference. Hence, as the feed pressure is increased, solvent or water
flow through the membrane increases and the solute flow remains approximately constant, giving lower
solute concentration in the product solution.

At a constant applied pressure, increasing the feed solute concentration increases the product solute
concentration. This is caused by the increase in the feed osmotic pressure, since as more solvent is
extracted from the feed solution (as water recovery increases), the solute concentration becomes higher
and the water flux decreases. Also, the amount of solute present in the product solution increases
because of the higher feed concentration.

If a reverse-osmosis unit has a large membrane area (as in a commercial unit), and the path between the
feed inlet and outlet is long, the outlet feed concentration can be considerably higher than the inlet feed
c1. Then the salt flux will be greater at the outlet feed as compared to the inlet (K2). Many manufacturers
use the feed solute or salt concentration average between inlet and outlet to calculate the solute or salt
rejection R in Eq. (13.9-7).

EXAMPLE 13.10­1. Prediction of Performance in a
Reverse­Osmosis Unit
A reverse-osmosis membrane to be used at 25°C for a NaCl feed solution containing 2.5 g
NaCl/L (2.5 kg NaCl/m3, ρ = 999 kg/m3) has a water permeability constant Aw  = 4.81 × 10-4

kg/s · m2 · atm and a solute (NaCl) permeability constant As = 4.42 × 10-7  m/s (A1). Calculate
the water flux and solute flux through the membrane using ΔP = 27.20 atm and the solute
rejection R. Also calculate c2 of the product solution.

S olu t ion: In the feed solution, c1 = 2.5 kg NaCl/m3 and ρ1 = 999 kg solution/m3. Hence, for

the feed, 999 - 2.5 = 996.5 kg H2O in 1.0 m3 solution: also for the feed, (2.50 × 1000)/(996.5 ×
58.45) = 0.04292 g mol NaCl/kg H2O. From Table 13.9-1, π1 = 1.97 atm. Since the product

solution c2 is unknown, a value of c2 = 0.1 kg NaCl/m3 will be assumed. Also, since this is

quite dilute, ρ2 = 997 kg solution/m3 and C w2 = 997 kg solvent/m3. Then for the product
solution, (0.10 × 1000)/(996.9 × 58.45) = 0.00172 g mol NaCl/kg H2O and π2 = 0.08 atm.
Also, Δπ = π1 - π2 = 1.97 - 0.08 = 1.89 atm.

Substituting into Eq. (13.9-2),
For calculation of R, substituting first into Eq. (13.9-9),

Next, substituting into Eq. (13.9-8),

Using this value of R in Eq. (13.9-7),

Solving, c2 = 0.0875 kg NaCl/m3 for the product solution. This is close enough to the assumed
value of c2 = 0.10 that π2 will not change significantly on a second trial. Hence, the final value

of c2 is 0.0875 kg NaCl/m3 (0.0875 g NaCl/L).

Substituting into Eq. (13.9-4),

13.10B. C once ntr ation Polar iza tion in R e v e r se -Osm osis Diffu sion M od e l

In desalination, localized concentrations of solute build up at the point where the solvent leaves the
solution and enters the membrane. The solute accumulates in a relatively stable boundary layer (Fig.
13.9-3) next to the membrane. Concentration polarization, β, is defined as the ratio of the salt
concentration at the membrane surface to the salt concentration in the bulk feed stream c1.
Concentration polarization causes the water flux to decrease, since the osmotic pressure π1 increases as
the boundary layer concentration increases and the overall driving force (ΔP - Δπ) decreases. Also, the
solute flux increases, since the solute concentration increases at the boundary. Hence, often the ΔP must
be increased to compensate, which results in higher power costs (K2).

The effect of the concentration polarization β can be included approximately by modifying the value of
Δπ in Eqs. (13.9-2) and (13.9-8) as follows (P6):

Equation 13.10-1

It is assumed that the osmotic pressure π1 is directly proportional to the concentration, which is
approximately correct. Also, Eq. (13.9-4) can be modified as

Equation 13.10-2

The usual concentration polarization ratio (K3) is 1.2 to 2.0, that is, the concentration in the boundary
layer is 1.2-2.0 times c1 in the bulk feed solution. This ratio is often difficult to predict. In desalination of
seawater, using values of about 1000 psia = ΔP, π1 can be large. Increasing this π1 by a factor of 1.2-2.0
can appreciably reduce the solvent flux. For brackish waters containing 2–10 g/L and using ΔP values of
17–55 atm abs, the value of π1 is low and concentration polarization is not important.

The boundary layer can be reduced by increasing the turbulence by using higher feed-solution velocities.
However, this extra flow results in a smaller ratio of product solution to feed. Also, screens can be put in
the path to induce turbulence. Equations for predicting the mass-transfer coefficient to the surface and,
hence, the concentration polarization, are given for specific geometries such as flow past plates, inside
tubes, outside tubes, and so on (H2, N1). Then equations for the flux of water can be used with these
mass-transfer coefficients in a manner similar to that for ultrafiltration given in Section 13.11.

13.10C . Pe r m e ab ility C onstants for  R e v e r se -Osm osis M e m b r ane s

Permeability constants for membranes must be determined experimentally for the particular type of
membrane to be used. For cellulose acetate membranes, typical water permeability constants Aw  range

from about 1 × 10-4 to 5 × 10-4 kg solvent/s · m2 · atm (A1, M3, W1). Values for other types of membranes
can differ widely. Generally, the water permeability constant for a particular membrane does not depend
upon the solute present. For the solute permeability constants AS of cellulose acetate membranes, some

relative typical values are as follows, assuming a value of As = 4 × 10-7  m/s for NaCl: 1.6 × 10-7  m/s

(BaCl2), 2.2 × 10-7  (MgCl2), 2.4 × 10-7  (CaCl2), 4.0 × 10-7  (Na2SO4), 6.0 × 10-7  (KC1), 6.0 × 10-7


(NH4C1) (A1).

13.10D. Typ e s of Eq u ip m e nt for  R e v e r se  Osm osis

The equipment for reverse osmosis is quite similar to that for gas permeation membrane processes
described in Section 13.3C. In the plate-and-frame-type unit, thin plastic support plates with thin
grooves are covered on both sides with membranes as in a filter press. Pressurized feed solution flows
between the closely spaced membranes (L1). Solvent permeates through the membrane and flows in the
grooves to an outlet. In the tubular-type unit, membranes in the form of tubes are inserted inside porous-
tube casings, which serve as a pressure vessel. These tubes are then arranged in bundles like a heat
exchanger.
In the spiral-wound type, a planar membrane is used and a flat, porous support material is sandwiched
between the membranes. Then the membranes, support, and a mesh feed-side spacer are wrapped in a
spiral around a tube. In the hollow-fiber type, fibers of 100–200 μm diameter with walls about 25 μm
thick are arranged in a bundle similar to a heat exchanger (L1, R1).

13.10E. C om p le te -M ixing M od e l for  R e v e r se  Osm osis

The process flow diagram for the complete-mixing model is shown in Fig. 13.10-1. The model is a
simplified one for use with low concentrations of salt of about 1% or so, such as occur in brackish waters.
Also, a relatively low recovery of solvent occurs and the effects of concentration polarization are small.
Since the concentration of the permeate is very low, the permeate side acts as though it were completely
mixed.

Figure 13.10-1. Process flow for complete-mixing model for reverse osmosis.

For the overall material balance for dilute solutions,

Equation 13.10-3

where qf is volumetric flow rate of feed, m3/s; q2 is flow rate of permeate, m3/s; and q1 is flow rate of

residue or exit, m3/s. Making a solute balance,

Equation 13.10-4

Defining the cut or fraction of solvent recovered as θ = q2/qf, Eq. (13.10-4) becomes

Equation 13.10-5
The equations previously derived for the fluxes and rejection are useful in this case and are as follows:

Equation 13.9-2

Equation 13.9-4

Equation 13.9-7

Equation 13.9-8

When the cut or fraction recovered, θ, is specified, the solution is trial and error. Since the permeate and
reject concentrations c1 and c2 are unknown, a value of c2 is assumed. Then c1 is calculated from Eq.
(13.10-5). Next, Nw  is obtained from Eq. (13.9-2) and c2 from Eqs. (13.9-7) and (13.9-8). If the calculated
value of c2 does not equal the assumed value, the procedure is repeated.

When concentration-polarization effects are present, an estimated value of β can be used to make an
approximate correction for these effects. This is used in Eq. (13.10-1) to obtain a value of Δπ for use in
Eqs. (13.9-2) and (13.9-8). Also, Eq. (13.10-2) will replace Eq. (13.9-4). A more detailed analysis of this
complete mixing model is given by others (H1, K1), in which the mass-transfer coefficient in the
concentration-polarization boundary layer is used.

The cross-flow model for reverse osmosis is similar to that for gas separation by membranes which was
discussed in Section 13.6. Because of the small solute concentration, the permeate side acts as if
completely mixed. Hence, even if the module is designed for countercurrent or cocurrent flow, the cross-
flow model is valid. This is discussed in detail elsewhere (H1).
                             
                                                 
                                             
                                               
     

13.11. ULTRAFILTRATION MEMBRANE PROCESSES

13.11A. Intr od u ction

Ultrafiltration is a membrane process that is quite similar to reverse osmosis. It is a pressure-driven
process where the solvent and, when present, small solute molecules pass through the membrane and are
collected as a permeate. Larger solute molecules do not pass through the membrane and are recovered in
a concentrated solution. The solutes or molecules to be separated generally have molecular weights
greater than 500 and up to 1 000 000 or more, such as macromolecules of proteins, polymers, and
starches as well as colloidal dispersions of clays, latex particles, and microorganisms.

Unlike reverse osmosis, ultrafiltration membranes are too porous to be used for desalting. The rejection
R, often called retention, is also given by Eq. (13.9-7), which is defined for reverse osmosis. Ultrafiltration
is also used to separate a mixture of different-molecular-weight proteins. The molecular-weight cut-off of
the membrane is defined as the molecular weight of globular proteins, which are 90% retained by the
membrane. A rule of thumb is that the molecular mass must differ by a factor of 10 for a good separation
(P7).

Ultrafiltration is used in many different processes at the present time. Some of these are separation of oil-
water emulsions, concentration of latex particles, processing of blood and plasma, fractionation or
separation of proteins, recovery of whey proteins in cheese manufacturing, removal of bacteria and other
particles to sterilize wine, and clarification of fruit juices.

Membranes for ultrafiltration are in general similar to those for reverse osmosis and are commonly
asymmetric and more porous. The membrane consists of a very thin, dense skin supported by a relatively
porous layer for strength. Membranes are made from aromatic polyamides, cellulose acetate, cellulose
nitrate, polycarbonate, polyimides, polysulfone, and so forth (M2, P6, R 1).

13.11B. Typ e s of Eq u ip m e nt for  Ultr afiltr ation

The equipment for ultrafiltration is similar to that used for reverse osmosis and gas separation processes,
described in Sections 13.3C and 13.10D. The tubular-type unit is less prone to fouling and more easily
cleaned than any of the other three types; however, this type is relatively costly.

Flat sheet membranes in a plate-and-frame unit offer the greatest versatility but at the highest capital
cost (P6). Membranes can easily be cleaned or replaced by disassembly of the unit. Spiral-wound
modules provide relatively low costs per unit membrane area. These units are more prone to fouling than
tubular units but are more resistant to fouling than hollow-fiber units. Hollow-fiber modules are the least
resistant to fouling as compared to the other three types. However, the hollow-fiber configuration has the
highest ratio of membrane area per unit volume.

Cross-flow filtration is the most common type of model used (P7). Spiral-wound flat sheets are used
most of all, followed by hollow-fiber units. Batch processes are also quite common. Stirred tanks with a
membrane are used which approximate cross-flow operation (R 1).

13.11C . Flu x Eq u ations for  Ultr afiltr ation


The flux equation for diffusion of solvent through the membrane is the same as Eq. (13.9-2) for reverse
osmosis:

Equation 13.9-2

In ultrafiltration the membrane does not allow passage of the solute, which is generally a macromolecule.
The concentration in moles/liter of the large solute molecules is usually small. Hence, the osmotic
pressure is very low and can be neglected. Then Eq. (13.9-2) becomes

Equation 13.11-1

Ultrafiltration units operate at about 5–100 psi pressure drop, compared to 400-2000 for reverse
osmosis. For low-pressure drops of, say, 5–10 psi and dilute solutions of up to 1 wt % or so, Eq. (13.11-1)
predicts the performance reasonably well for well-stirred systems.

Since the solute is rejected by the membrane, it accumulates and starts to build up at the surface of the
membrane. As pressure drop is increased and/or concentration of the solute is increased, concentration
polarization occurs, which is much more severe than in reverse osmosis. This is shown in Fig. 13.11-1a,
where c1 is the concentration of the solute in the bulk solution, kg solute/m3, c s  is the concentration of
the solute at the surface of the membrane, and c p  is the concentration in the permeate.

Figure 13.11-1. Concentr ation polarization in ultr afiltr ation: (a) concentr ation profile before gel formation, (b)


concentr ation profile with a gel layer formed at membrane surface.

As the pressure drop increases, this increases the solvent flux Nw  to and through the membrane. This
results in a higher convective transport of the solute to the membrane, that is, the solvent carries with it
more solute. The concentration c s  increases and gives a larger back molecular diffusion of solute from the
membrane to the bulk solution. At steady state the convective flux equals the diffusion flux:

Equation 13.11-2

where Nw c/ρ = [kg solvent/(s · m2)](kg solute/m3)/(kg solvent/m3) = kg solute/s · m2; DAB is diffusivity

of solute in solvent, m2/s; and x is distance, m. Integrating this equation between the limits of x = 0 and
c = cs and x = δ and c = c1,

Equation 13.11-3

where kc is the mass-transfer coefficient, m/s. Further increases in pressure drop increase the value of cs
to a limiting concentration, at which the accumulated solute forms a semisolid gel where cs = cg, as
shown in Fig. 13.11-1b. For the usual case of almost-complete solute retention (P7), cp = 0 and Eq. (13.11-
3) becomes

Equation 13.11-4

Still further increases in pressure drop do not change cg and the membrane is said to be "gel polarized."
Then Eq. (13.11-3) becomes (P1, P6, R1)

Equation 13.11-5

With increases in pressure drop, the gel layer increases in thickness, causing the solvent flux to decrease
because of the added gel-layer resistance. Finally, the net flux of solute by convective transfer becomes
equal to the back diffusion of solute into the bulk solution because of the polarized concentration
gradient, as given by Eq. (13.11-5).

The added gel-layer resistance next to the membrane causes an increased resistance to solvent flux, as
given by
Equation 13.11-6

where 1/Aw  is the membrane resistance and Rg is the variable gel-layer resistance, (s · m2 · atm)/kg
solvent. The solvent flux in this gel-polarized regime is independent of pressure difference and is
determined by Eq. (13.11-5) for back diffusion. Experimental data confirm the use of Eq. (13.11-5) for a
large number of macromolecular solutions, such as proteins and so forth as well as colloidal suspensions,
such as latex particles and so forth (P1, P6).

13.11D. Effe cts of Pr oce ssing Var iab le s in Ultr afiltr ation

A plot of typical experimental data for flux versus pressure difference is shown in Fig. 13.11-2 (H1, P6). At
low pressure differences and/or low solute concentrations, the data typically follow Eq. (13.11-1). For a
given bulk concentration, c1, the flux approaches a constant value at high pressure differences, as shown
in Eq. (13.11-5). Also, more-dilute protein concentrations give higher flux rates, as expected from Eq.
(13.11-5). Most commercial applications are flux-limited by concentration polarization and operate in the
region where the flux is approximately independent of pressure difference (R1).

Figure 13.11-2. Effe ct of pressure diffe rence on solvent flux.

Using experimental data, a plot of Nw /p versus In c1 is a straight line with a negative slope of kc, the
mass-transfer coefficient, as shown by Eq. (13.11-5). These plots also give the value of cg, the gel
concentration. Data (P1) show that the gel concentration for many macromolecular solutions is about 25
wt %, with a range of 5 to 50%. For colloidal dispersions it is about 65 wt %, with a range of 50 to 75%.

The concentration-polarization effects for hollow fibers are often quite small, due to the low solvent flux.
Hence, Eq. (13.11-1) describes the flux. In order to increase the ultrafiltration solvent flux, cross-flow of
fluid past the membrane can be used to sweep away part of the polarized layer, thereby increasing kc in
Eq. (13.11-5). Higher velocities and other methods are used to increase turbulence and hence kc. In most
cases the solvent flux is too small to operate in a single-pass mode. It is necessary to recirculate the feed
past the membrane, with recirculation rates of 10/1 to 100/1 often used.

Methods for predicting the mass-transfer coefficient kc in Eq. (13.11-5) are given by others (P1, P6) for
known geometries such as channels and so forth. Predictions of flux in known geometries using these
methods and experimental values of cg in Eq. (13.11-5) in the gel polarization regime compare with
experimental values for macromolecular solutions within about 25–30%. However, for colloidal
dispersions the experimental flux is higher than the theoretical by factors of 20-30 for laminar flow and
8-10 for turbulent flow. Hence, Eq. (13.11-5) is not useful for predicting the solvent flux accurately.
Generally, for design of commercial units it is necessary to obtain experimental data on single modules.
                             
                                                 
                                             
                                               
     

13.12. MICROFILTRATION MEMBRANE PROCESSES

13.12A. Intr od u ction

In microfiltration, pressure-driven flow through a membrane is used to separate micron-size particles
from fluids. The size range of particles ranges from 0.02 μm to 10 μm (H2). This microfiltration separates
particles from solutions. The particles are usually larger than the solutes in reverse osmosis and
ultrafiltration. Hence, osmotic pressure is negligible. At the very low end of the size range, very large
soluble macromolecules are retained. Bacteria and other microorganisms (P7) are also retained on these
membranes. Other particles in this size range are paint pigment, yeast cells, suspended matter such as
cells from fermentation broth, particles in beer pasteurization, and so on. The dividing line between
ultrafiltration and microfiltration is not very distinct.

The pore sizes of the membranes and the permeate flux are typically larger than for reverse osmosis and
ultrafiltration. Usually the pressure drop used across the membranes varies from 1 psi to 50 psi (H2).
Types of membranes are extremely varied and can be ceramics, polymers, and so on.

Many different geometries of membranes are used. These include spiral-wound, plate and frame, hollow
fiber, cartridge filters with pleated membranes, and so on. Disposable cartridges are also used.

13.12B. M od e ls for  M icr ofiltr ation

1. Dea d -end  micr ofilt r a t ion flow  mod el

In many laboratory batch filtrations, the batch process is run in dead-end flow, with the membrane
replacing the conventional filter paper. The particles build up with time as a cake and the clarified
permeate is forced through the membrane, as shown in Fig. 13.12-1a. The permeate flux equation is (H2)

Equation 13.12-1

Figure 13.12-1. Process flow for microfiltr ation: (a) dead-end flow, (b) cross-flow.

[View full size image]
where Nw  is the solvent flux in kg/(s · m2), ΔP is the pressure difference in Pa, μ is viscosity of the solvent

in Pa · s, Rm is the membrane resistance in m2/kg, and Rc is the cake resistance in m2/kg, which
increases with time due to cake buildup.

This Eq. (13.12-1) is similar to Eq. (14.2-8) for ordinary filtration given in Section 14.2 of this text.
Solutions to this equation are also given there.

2. C r oss-flow  micr ofilt r a t ion flow  mod el

In the cross-flow model shown in Fig. 13.12-1b, the operation is similar to that for reverse osmosis and
ultrafiltration in that the flow of bulk solution is parallel to the membrane surface and not through it
(H2). The permeate flow through the membrane carries particles to the surface, where they form a thin
layer. A relatively high flow rate tangential to the surface sweeps the deposited particles toward the filter
exit leaving a relatively thin deposited cake layer. This thin cake layer is similar to the gel layer formed in
ultrafiltration. This cross-flow is effective in controlling concentration polarization and cake buildup,
allowing relatively high fluxes to be maintained.

This concentration-polarization model of convection of particles to the cake layer is balanced by particle
diffusion by Brownian diffusion away from the cake surface. This model is similar to the flux Eq. (13.11-3)
for ultrafiltration. Other models are also given elsewhere (H2).
                             
                                                 
                                             
                                               
     

PROBLEMS
13.2-1.
Diffu sion Thr ou g h Liq u id s a nd  a  M emb r a ne. A membrane process is being designed to
recover solute A from a dilute solution where c1 = 2.0 × 10-2 kg mol A/m3 by dialysis through a

membrane to a solution where c2 = 0.3 × 10-2. The membrane thickness is 1.59 × 10-5 m, the

distribution coefficient K' = 0.75, DAB = 3.5 × 10-11 m2/s in the membrane, the mass-transfer

coefficient in the dilute solution is kc1 = 3.5 × 10-5 m/s, and kc2 = 2.1 × 10-5.

a.  Calculate the individual resistances, total resistance, and total percent resistance of the
two films.

b.  Calculate the flux at steady state and the total area in m2 for a transfer of 0.01 kg mol
solute/h.

c.  Increasing the velocity of both liquid phases flowing past the surface of the membrane will
increase the mass-transfer coefficients, which are approximately proportional to v0.6,
where v is velocity. If the velocities are doubled, calculate the total percent resistance of
the two films and the percent increase in flux.

A1: Ans.  (a) Total resistance = 6.823 × 105 s/m, 11.17% resistance; (b) N  = 2.492 × 10-8 kg mol A/s


A
· m2, area = 111.5 m2
13.2-2.
S u it a b ilit y  of a  M emb r a ne for  Hemod ia ly sis. Experiments are being conducted to
determine the suitability of a cellophane membrane 0.029 mm thick for use in an artificial-
kidney device. In an experiment at 37°C using NaCl as the diffusing solute, the membrane
separates two components containing stirred aqueous solutions of NaCl, where c1 = 1.0 × 10-4 g

mol/cm3 (100 g mol/m3) and c2 = 5.0 × 10-7 . The mass-transfer coefficients on either side of the

membrane have been estimated as kc1 = kc2 = 5.24 × 10-5 m/s. Experimental data obtained gave

a flux NA = 8.11 × 10-4 g mol NaCl/s · m2 at pseudo-steady-state conditions.

a.  Calculate the permeability pM in m/s and DABK' in m2/s.

b.  Calculate the percent resistance to diffusion in the liquid films.

13.3-1.
G a s-Per mea t ion M emb r a ne for  Oxy g ena t ion. To determine the suitability of silicone
rubber for its use as a membrane for a heart-lung machine to oxygenate blood, an experimental
value of the permeability at 30°C of oxygen was obtained, where PM = 6.50 × 10-7  cm3 O2

(STP)/(s · cm2 · cm Hg/mm).
a.  Predict the maximum flux of O2 in kg mol/s · m2 with an O2 pressure of 700 mm Hg on
one side of the membrane and an equivalent pressure in the blood film side of 50 mm. The
membrane is 0.165 mm thick. Since the gas film is pure oxygen, the gas film resistance is
zero. Neglect the blood film resistance in this case.

b.  Assuming a maximum requirement for an adult of 300 cm3 O2 (STP) per minute,

calculate the membrane surface area required in m2. (Note: The actual area needed should
be considerably larger since the blood film resistance, which must be determined by
experiment, can be appreciable.)

A3: Ans.  (b) 1.953 m2


13.4 -1.
Der iv a t ion of Eq u a t ion for  Per mea t e C oncent r a t ion. Derive Eq. (13.4-11) for Case 2 for
complete mixing. Note that xo from Eq. (13.4-9) must first be substituted into Eq. (13.4-6)
before multiplying out the equation and solving for y p.
13.4 -2.
Use of C omp let e-M ixing  M od el for  M emb r a ne Desig n. A membrane having a thickness

of 2 × 10-3 cm, permeability   = 400 × 10-10 cm3 (STP) · cm/(s · cm2 · cm Hg), and   = 10 is


to be used to separate a gas mixture of A and B. The feed flow rate is Lf = 2 × 103 cm3 (STP)/s
and its composition is xf = 0.413. The feed-side pressure is 80 cm Hg and the permeate-side
pressure is 20 cm Hg. The reject composition is to be xo = 0.30. Using the complete-mixing
model, calculate the permeate composition, fraction of feed permeated, and membrane area.
A5:Ans. y p = 0.678
13.4 -3.
Desig n Using  C omp let e-M ixing  M od el. A gaseous feed stream having a composition xf =

0.50 and a flow rate of 2 × 103 cm3 (STP)/s is to be separated in a membrane unit. The feed-side
pressure is 40 cm Hg and the permeate is 10 cm Hg. The membrane has a thickness of 1.5 × 10-3

cm, permeability   = 40 × 10-10 cm3 (STP) cm/(s · cm2 · cm Hg), and   = 10. The fraction of


feed permeated is 0.529.

a.  Use the complete-mixing model to calculate the permeate composition, reject
composition, and membrane area.

b.  Calculate the minimum reject concentration.

c.  If the feed composition is increased to xf = 0.60, what is this new minimum reject
concentration?

A6 : Ans.  (a) A  = 5.153 × 107  cm2 (c) x  = 0.2478


m oM
13.4 -4 .
Effect  of Per mea b ilit ies on M inimu m R eject  C oncent r a t ion. For the conditions of

Problem 13.4-2, xf = 0.413,   = 10, pl = 20 cm Hg, ph = 80 cm Hg, and xo = 0.30. Calculate the
minimum reject concentration for the following cases:
a.  Calculate xoM for the given conditions.

b.  Calculate the effect on xoM if the permeability of B increases so that   decreases to 5.

c.  Calculate the limiting value of xoM when   is lowered to its minimum value of 1.0. Make

a plot of xoM versus   for these three cases.

13.4 -5.
M inimu m R eject  C oncent r a t ion a nd  Pr essu r e Effect . For Example 13.4-2 for separation
of air, do as follows:

a.  Calculate the minimum reject concentration.

b.  If the pressure on the feed side is reduced by one-half, calculate the effect on xoM.

A8:Ans. (b) xoM = 0.0624
13.5-1.
S ep a r a t ion of M u lt icomp onent  G a s M ixt u r es. Using the same feed composition and flow
rate, pressures, and membrane as in Example 13.5-1, do the following, using the complete-
mixing model:

a.  Calculate the permeate composition, reject composition, and membrane area for a
fraction permeated of 0.50 instead of 0.25.

b.  Repeat part (a) but for θ = 0.90.

c.  Make a plot of permeate composition y pA versus θ and also of area Am versus θ using the


calculated values for θ = 0.25, 0.50, and 0.90.

13.5-2.
S ep a r a t ion of Heliu m fr om Na t u r a l G a s. A typical composition of a natural gas (S1) is
0.5% He (A), 17.0% N2 (B), 76.5% CH4 (C), and 6.0% higher hydrocarbons (D). The membrane

proposed to separate helium has a thickness of 2.54 × 10-3 cm, and the permeabilities are   =

60 × 10-10 cm3 (STP) · cm/(s · cm2 · cm Hg),   = 3.0 × 10-10, and   = 1.5 × 10-10. It is

assumed that the higher hydrocarbons are essentially nonpermeable (  ≅ 0). The feed flow
rate is 2.0 × 105 cm3 (STP)/s. The feed pressure ph = 500 cm Hg and the permeate pressure pl =
20 cm Hg.

a.  For a fraction permeated of 0.2, calculate the permeate composition, reject composition,
and membrane area using the complete mixing model.

b.  Use the permeate from part (a) as feed to a completely mixed second stage. The pressure
ph = 500 cm Hg and pl = 20 cm. For a fraction permeated of 0.20, calculate the permeate
composition and membrane area.
13.6 -1.Desig n Using  C r oss-Flow  M od el for  M emb r a ne. Use the same conditions for the

separation of an air stream as given in Example 13.6-1. The given values are xf = 0.209,   = 10,

ph = 190 cm Hg, pl = 19 cm Hg, Lf = 1 × 106 cm3 (STP)/s,   = 500 × 10-10 cm3 (STP) · cm/(s ·

cm2 · cm Hg), and t = 2.54 × 10-3 cm. Do as follows using the cross-flow model:

a.  Calculate y p, xo, and Am for θ = 0.40.

b.  Calculate y p and xo for θ = 0.

A11: Ans.  (a) y  = 0.452, x  = 0.0303, A  = 6.94 × 108 cm2 (S6); (b) y  =  0.655, x  = 0.209


p o m p o
13.7-1.
Eq u a t ions for  C ocu r r ent  a nd  C ou nt er cu r r ent  Flow  M od els. Derive the equations for the
following cases:

a.  For cocurrent flow, show the detailed steps for deriving Eqs. (13.7-35) and (13.7-36).

b.  For countercurrent flow, show the detailed steps in obtaining Eq. (13.7-22) from (13.7-4)
and (13.7-5). Also, show the detailed steps to derive Eq. (13.7-24).

13.7-2.
Desig n Using  C ou nt er cu r r ent -Flow  M od el for  M emb r a ne. Use the same conditions as

given in Example 13.6-1 for the separation of an air stream. The given values are xf = 0.209, 

= 10, ph = 190 cm Hg, pl = 19 cm Hg, Lf = 1 × 106 cm3 (STP)/s,   = 500 × 10-10 cm3 (STP) ·

cm/(s · cm2 · cm Hg), and t = 2.54 × 10-3 cm. Using the countercurrent-flow model, calculate y p,
xo, and Am for θ = 0.40. (Note that this problem involves a trial-and-error procedure along with
the numerical solution of two differential equations.)
13.8-1.
Effect  of Pr essu r e Dr op  on Asy mmet r ic M emb r a ne C a lcu la t ions. Using the same
conditions as in Example 13.8-1, do as follows:

a.  Use the shortcut method to calculate the overall pressure drop Δph using Eq. (13.8-16)
over the entire length. Use typical data for air given in Section 13.8C to calculate NT, fiber
length z2 - z1, and so forth. Assume T = 25° + 273 K and ph = 1034 kPa, Ts = 273 K, ps =
101.325 kPa.

b.  With the above values of ph, use the shortcut method in a second iteration to recalculate

Am. (Be sure to correct for Pho at xo and  ).

c.  Calculate the pressure drop if the number of tubes NT in part (a) is reduced by 50%.

A14 : Ans.  (a) N  = 1.267 × 105, (z  − z ) = 1.413 m, Δp  = 20.74 kPa; (b) A  = 54.10 m2; (c) Δp  =


T 2 1 h m h
82.96 kPa
13.8-2.
S p r ea d she et  C a lcu la t ion for  Asy mmet r ic M emb r a ne. Using the conditions for Example
13.8-1, write the detailed spreadsheet and calculate the results. Compare these results with
those in Table 13.8-2.
13.8-3.
C omp a r ison of Exp er iment a l a nd  Pr ed ict ed  S p r ea d she et  R esu lt s in a  Pilot -Unit
Asy mmet r ic M emb r a ne. A pilot-size membrane used to separate air in order to obtain
nitrogen has the following dimensions with the feed inside the tubes: total NT = 3.8 × 104 fibers,
ID = 95 μm, OD = 135 μm, length of fibers = 19 in. An experimental run gave the following
results. Feed rate Lf = 1.086 m3/h, Lo = 0.654 m3/h, Vp = 0.450 m3/h, xo = 0.067 mole fraction
oxygen, y p = 0.413, ph = 703.81 kPa, pl = 98.10 kPa, and T = 25°C. The permeances determined

previously are (P'O2/t) = 1.50 × 10-10 m3 (STP)/(s · m2 · Pa), (P'N2/t) = 2.47 × 10-11. Flow is
counter current. Do as follows:

a.  Predict the pressure drop in the tubes using the shortcut method.

b.  Using a spreadsheet, predict the performance of this run and compare these results with
the experimental values. Note that this is trial and error, since the area is fixed but the
value of xo is not. First assume a value of xo. Then divide the difference between xf =
0.209 and xo into nine equal parts and perform the spreadsheet calculation. If the
calculated and actual areas do not agree, assume another value of xo, and so forth.
Neglect pressure drop.

A16 : Ans.  (a) Δp  = 4.455 kPa; (b) x  = 0.079, V  = 0.442 m3/hr, y  = 0.398


h o p p
13.9 -1.
Osmot ic Pr essu r e of S a lt  a nd  S u g a r  S olu t ions. Calculate the osmotic pressure of the
following solutions at 25°C and compare with the experimental values:

a.  Solution of 0.50 g mol NaCl/kg H2O. (See Table 13.9-1 for the experimental value.)

b.  Solution of 1.0 g sucrose/kg H2O. (Experimental value = 0.0714 atm.)

c.  Solution of 1.0 g MgCl2/kg H2O. (Experimental value = 0.660 atm.)

A17:Ans. (a) π = 24.39 atm; (b) π = 0.0713 atm; (c) π = 0.768 atm
13.9 -2.
Det er mina t ion of Per mea b ilit y  C onst a nt s for  R ev er se Osmosis. A cellulose-acetate
membrane with an area of 4.0 × 10-3 m2 is used at 25°C to determine the permeability constants
for reverse osmosis of a feed salt solution containing 12.0 kg NaCl/m3 (ρ = 1005.5 kg/m3). The
product solution has a concentration of 0.468 kg NaCl/m3 (ρ = 997.3 kg/m3). The measured
product flow rate is 3.84 × 10-8 m3/s and the pressure difference used is 56.0 atm. Calculate the
permeability constants and the solute rejection R.

A18: Ans.  A  = 2.013 × 10-4 kg solvent/s · m2 · atm, R =  0.961


w
13.9 -3.
Per for ma nce of a  La b or a t or y  R ev er se-Osmosis Unit . A feed solution at 25°C contains
3500 mg NaCl/L (ρ = 999.5 kg/m3). The permeability constant Aw  = 3.50 × 10-4 kg solvent/s ·
m2 · atm and As = 2.50 × 10-7  m/s. Using a ΔP = 35.50 atm, calculate the fluxes, solute rejection
R, and product solution concentration in mg NaCl/L. Repeat, but using a feed solution of 3500
mg BaCl2/L. Use the same value of Aw , but As = 1.00 × 10-7  m/s (A1).
13.10-
Effect  of Pr essu r e on Per for ma nce of R ev er se-Osmosis Unit . Using the same conditions
1.
and permeability constants as in Example 13.10-1, calculate the fluxes, solute rejection R, and
product concentration c2 for ΔP pressures of 17.20, 27.20, and 37.20 atm. (Note: The values for
27.20 atm have already been calculated.) Plot the fluxes, R, and c2 versus the pressure.
13.10-
Effect  of C oncent r a t ion Pola r iza t ion on R ev er se Osmosis. Repeat Example 13.10-1 but
2.
use a concentration polarization of 1.5. (Note: The flux equations and the solute rejection R
should be calculated using this new value of c1.)
A21: Ans.  N  = 1.171 × 10-2 kg solvent/s · m2, c  = 0.1361 kg NaCl/m3
w 2
13.10-
Per for ma nce of a  C omp let e-M ixing  M od el for  R ev er se Osmosis. Use the same feed
3.
conditions and pressures given in Example 13.10-1. Assume that the cut or fraction recovered of
the solvent water will be 0.10 instead of the very low water recovery assumed in Example 13.10-
1. Hence, the concentrations of the entering feed solution and the exit feed will not be the same.
The flow rate q2 of the permeate water solution is 100 gal/h. Calculate c1 and c2 in kg NaCl/m3

and the membrane area in m2.
A22: Ans.  c  = 2.767 kg/m3, c  = 0.0973 kg/m3, area = 8.68 m2
1 2
13.11-1.
Flu x for  Ult r a filt r a t ion. A solution containing 0.9 wt % protein is to undergo ultrafiltration
using a pressure difference of 5 psi. The membrane permeability is Aw  = 1.37 × 10-2 kg/s · m2 ·

atm. Assuming no effects of polarization, predict the flux in kg/s · m2 and in units of gal/ft 2 ·
day, which are often used in industry.
A23: Ans.  9.88 gal/ft 2 · day
13.11-2.
Time for  Ult r a filt r a t ion Using  R ecir cu la t ion. It is desired to use ultrafiltration for 800 kg
of a solution containing 0.05 wt % of a protein to obtain a solution of 1.10 wt %. The feed is
recirculated past the membrane with a surface area of 9.90 m2. The permeability of the
membrane is Aw  = 2.50 × 10-2 kg/s · m2 · atm. Neglecting the effects of concentration
polarization, if any, calculate the final amount of solution and the time to achieve this, using a
pressure difference of 0.50 atm.
                             
                                                 
                                             
                                               
     

Chapter 14. Mechanical–Physical Separation Processes
                             
                                                 
                                             
                                               
     

14.1. INTRODUCTION AND CLASSIFICATION OF MECHANICAL–
PHYSICAL SEPARATION PROCESSES

14 .1A. Intr od u ction

In Chapters 10 and 11, gas–liquid and vapor–liquid separation processes were considered. These
separation processes depended on molecules diffusing or vaporizing from one distinct phase to another
phase. In Chapter 12, liquid–liquid separation processes were discussed, in which the two liquid phases
are quite different chemically, leading to separation on a molecular scale according to physical–chemical
properties. Also in Chapter 12, we considered liquid–solid leaching, ion-exchange, and adsorption
separation processes. Again, differences in the physical–chemical properties of the molecules lead to
separation on a molecular scale. In Chapter 13, we discussed membrane separation processes, where the
separation also depends on physical–chemical properties.

All the separation processes considered so far have been based upon physical–chemical differences in the
molecules themselves and on mass transfer of the molecules. In this way individual molecules are
separated into two phases because of these molecular differences. In the present chapter, a group of
separation processes will be considered where the separation is not accomplished on a molecular scale
nor is it due to the differences among the various molecules. The separation will be accomplished using
mechanical–physical forces and not molecular or chemical forces and diffusion. These mechanical–
physical forces will be acting on particles, liquids, or mixtures of particles and liquids themselves and not
necessarily on the individual molecules.

These mechanical–physical forces include gravitational and centrifugal, actual mechanical, and kinetic
forces arising from flow. Particles and/or fluid streams are separated because of the different effects
produced on them by these forces.

14 .1B. C lassification of M e chanical–Physical S e p ar ation Pr oce sse s

These mechanical–physical separation processes are considered under the following classifications:

1. Filt r a t ion

The general problem of the separation of solid particles from liquids can be solved by using a wide variety
of methods, depending on the type of solids, the proportion of solid to liquid in the mixture, viscosity of
the solution, and other factors. In filtration, a pressure difference is set up that causes the fluid to flow
through small holes in a screen or cloth which block the passage of the large solid particles; these, in
turn, build up on the cloth as a porous cake.

2. S et t ling  a nd  sed iment a t ion

In settling and sedimentation, the particles are separated from the fluid by gravitational forces acting on
particles of various sizes and densities.

3. C ent r ifu g a l set t ling  a nd  sed iment a t ion


In centrifugal separations, the particles are separated from the fluid by centrifugal forces acting on
particles of various sizes and densities. Two general types of separation processes are used. In the first
type of process, centrifugal settling or sedimentation occurs.

4 . C ent r ifu g a l filt r a t ion

In the second type of centrifugal separation process, centrifugal filtration occurs, which is similar to
ordinary filtration, where a bed or cake of solids builds up on a screen, but centrifugal force is used to
cause the flow instead of a pressure difference.

5. M echa nica l size r ed u ct ion a nd  sep a r a t ion

In mechanical size reduction, the solid particles are broken mechanically into smaller particles and
separated according to size.
                             
                                                 
                                             
                                               
     

14.2. FILTRATION IN SOLID–LIQUID SEPARATION

14 .2A. Intr od u ction

In filtration, suspended solid particles in a fluid of liquid or gas are physically or mechanically removed
by using a porous medium that retains the particles as a separate phase or cake and passes the clear
filtrate. Commercial filtrations cover a very wide range of applications. The fluid can be a gas or a liquid.
The suspended solid particles can be very fine (in the micrometer range) or much larger, very rigid or
plastic particles, spherical or very irregular in shape, aggregates of particles or individual particles. The
valuable product may be the clear filtrate from the filtration or the solid cake. In some cases, complete
removal of the solid particles is required, in other cases only partial removal.

The feed or slurry solution may carry a heavy load of solid particles or a very small amount. When the
concentration is very low, the filters can operate for very long periods of time before the filter needs
cleaning. Because of the wide diversity of filtration problems, a multitude of types of filters have been
developed.

Industrial filtration equipment differs from laboratory filtration equipment only in the amount of
material handled and in the necessity for low-cost operation. A typical laboratory filtration apparatus is
shown in Fig. 14.2-1, which is similar to a Büchner funnel. The liquid is made to flow through the filter
cloth or paper by a vacuum on the exit end. The slurry consists of the liquid and the suspended particles.
The passage of the particles is blocked by the small openings in the pores of the filter cloth. A support
with relatively large holes is used to hold the filter cloth. The solid particles build up in the form of a
porous filter cake as the filtration proceeds. This cake itself also acts as a filter for the suspended
particles. As the cake builds up, resistance to flow also increases.

Figure 14.2-1. Simple laboratory filtr ation apparatus.

In section 14.2 the ordinary type of filtration will be considered, where a pressure difference is used to
force the liquid through the filter cloth and the filter cake that builds up.

In Section 14.4E, centrifugal filtration will be discussed, where centrifugal force is used instead of a
pressure difference. In many filtration applications, ordinary filters and centrifugal filters are often
competitive and either type can be used.

14 .2B. Typ e s of Filtr ation Eq u ip m e nt

1. C la ssifica t ion of filt er s

There are a number of ways to classify types of filtration equipment; unfortunately, it is not possible to
devise a single classification scheme that includes all types of filters. In one classification, filters are
classified according to whether the desired product is the filter cake or the clarified filtrate or outlet
liquid. In either case, the slurry can have a relatively large percentage of solids so that a cake is formed, or
have just a trace of suspended particles.

Filters can also be classified by operating cycle. Filters can be operated as batch, where the cake is
removed after a run, or continuous, where the cake is removed continuously. In another classification,
filters can be of the gravity type, where the liquid simply flows by means of a hydrostatic head, or
pressure or vacuum can be used to increase the flow rates. An important method of classification
depends upon the mechanical arrangement of the filter media. The filter cloth can be in a series
arrangement as flat plates in an enclosure, as individual leaves dipped in the slurry, or on rotating-type
rolls in the slurry. In the following sections only the most important types of filters will be described. For
more details, see references (B1, P1).

2. Bed  filt er s

The simplest type of filter is the bed filter shown schematically in Fig. 14.2-2. This type is useful mainly
in cases where relatively small amounts of solids are to be removed from large amounts of water in
clarifying the liquid. Often the bottom layer is composed of coarse pieces of gravel resting on a perforated
or slotted plate. Above the gravel is fine sand, which acts as the actual filter medium. Water is introduced
at the top onto a baffle which spreads the water out. The clarified liquid is drawn out at the bottom.

Figure 14.2-2. Bed filter of solid particles.

The filtration continues until the precipitate of filtered particles has clogged the sand so that the flow rate
drops. Then the flow is stopped, and water is introduced in the reverse direction so that it flows upward,
backwashing the bed and carrying the precipitated solid away. This apparatus can only be used on
precipitates that do not adhere strongly to the sand and can be easily removed by backwashing. Open-
tank filters are used in filtering municipal water supplies.

3. Pla t e-a nd -fr a me filt er  p r esses


One of the important types of filters is the plate-and-frame filter press, which is shown diagrammatically
in Fig. 14.2-3a. These filters consist of plates and frames assembled alternately with a filter cloth over
each side of the plates. The plates have channels cut in them so that clear filtrate liquid can drain down
along each plate. The feed slurry is pumped into the press and flows through the duct into each of the
open frames so that slurry fills the frames. The filtrate flows through the filter cloth and the solids build
up as a cake on the frame side of the cloth. The filtrate flows between the filter cloth and the face of the
plate through the channels to the outlet.

Figure 14.2-3. Diagrams of plate-and-frame filter presses: (a) filtration of slurry with closed delivery, (b)
through washing in a press with open delivery.
The filtration proceeds until the frames are completely filled with solids. In Fig. 14.2-3a all the discharge
outlets go to a common header. In many cases the filter press will have a separate discharge to the open
for each frame. Then visual inspection can be made to see if the filtrate is running clear. If one is running
cloudy because of a break in the filter cloth or other factors, it can be shut off separately. When the frames
are completely full, the frames and plates are separated and the cake removed. Then the filter is
reassembled and the cycle is repeated.

If the cake is to be washed, the cake is left in the plates and through-washing is performed, as shown in
Fig. 14.2-3b. In this press a separate channel is provided for the wash-water inlet. The wash water enters
the inlet, which has ports opening behind the filter cloths at every other plate of the filter press. The wash
water then flows through the filter cloth, through the entire cake (not half the cake as in filtration),
through the filter cloth at the other side of the frames, and out the discharge channel. It should be noted
that there are two kinds of plates in Fig. 14.2-3b: those having ducts to admit wash water behind the
filter cloth, alternating with plates without such ducts.

The plate-and-frame presses suffer from the disadvantages common to batch processes. The cost of labor
for removing the cakes and reassembling plus the cost of fixed charges for downtime can be an
appreciable part of the total operating cost. Some newer types of plate-and-frame presses have duplicate
sets of frames mounted on a rotating shaft. Half of theframes are in use while the others are being
cleaned, saving downtime and labor costs. Other advances in automation have been applied to these
types of filters.

Filter presses are used in batch processes but cannot be employed for high-throughput processes. They
are simple to operate, very versatile and flexible in operation, and can be used at high pressures, when
necessary, if viscous solutions are being used or the filter cake has a high resistance.

4 . Lea f filt er s

The filter press is useful for many purposes but is not economical for handling large quantities of sludge
or for efficient washing with a small amount of wash water. The wash water often channels in the cake
and large volumes of wash water may be needed. The leaf filter shown in Fig. 14.2-4 was developed for
larger volumes of slurry and more efficient washing. Each leaf is a hollow wire framework covered by a
sack of filter cloth.

Figure 14.2-4. Leaf filter.
A number of these leaves are hung in parallel in a closed tank. The slurry enters the tank and is forced
under pressure through the filter cloth, where the cake deposits on the outside of the leaf. The filtrate
flows inside the hollow framework and out a header. The wash liquid follows the same path as the slurry.
Hence, the washing is more efficient than the through-washing in plate-and-frame filter presses. To
remove the cake, the shell is opened. Sometimes air is blown in the reverse direction into the leaves to
help in dislodging the cake. If the solids are not wanted, water jets can be used to simply wash away the
cakes without opening the filter.

Leaf filters also suffer from the disadvantages of batch operation. They can be automated for the filtering,
washing, and cleaning cycle. However, they are still cyclical and are used for batch processes and
relatively modest throughput processes.

5. C ont inu ou s r ot a r y  filt er s

Plate-and-frame filters suffer from the disadvantages common to all batch processes and cannot be used
for large-capacity processes. A number of continuous-type filters are available, as discussed below.

a.  Continuous rotary vacuum-drum filter. This filter, shown in Fig. 14.2-5, filters, washes, and
discharges the cake in a continuous, repeating sequence. The drum is covered with a suitable
filtering medium. The drum rotates and an automatic valve in the center serves to activate the
filtering, drying, washing, and cake-discharge functions in the cycle. The filtrate leaves through
the axle of the filter.

Figure 14.2-5. Schematic of continuous rotary-drum filter.

The automatic valve provides separate outlets for the filtrate and the wash liquid. Also, if needed,
a connection for compressed-air blowback just before discharge can be used to help in cake
removal by the knife scraper. The maximum pressure differential for the vacuum filter is only 1
atm. Hence, this type is not suitable for viscous liquids or for liquids that must be enclosed. If the
drum is enclosed in a shell, pressures above atmospheric can be used; however, the cost of a
pressure-type filter is about two times that of a vacuum-type rotary-drum filter (P2).
Modern, high-capacity processes use continuous filters. The important advantages are that the
filters are continuous and automatic and labor costs are relatively low. However, the capital cost is
relatively high.

b.  Continuous rotary disk filter. This filter consists of concentric vertical disks mounted on a
horizontal rotating shaft. The filter operates on the same principle as the vacuum rotary-drum
filter. Each disk is hollow and covered with a filter cloth and is partly submerged in the slurry. The
cake is washed, dried, and scraped off when the disk is in the upper half of its rotation. Washing is
less efficient than with the rotating-drum type.

c.  Continuous rotary horizontal filter. This type is a vacuum filter with the rotating annular filtering
surface divided into sectors. As the horizontal filter rotates, it successively receives slurry, is
washed, is dried, and the cake is scraped off. The washing efficiency is better than with the rotary-
disk filter. This filter is widely used in ore-extraction processes, pulp washing, and other large-
capacity processes.

14 .2C . Filte r  M e d ia and  Filte r  Aid s

1. Filt er  med ia

The filter medium for industrial filtration must fulfill a number of requirements. First and foremost, it
must remove the solids to be filtered from the slurry and give a clear filtrate. Also, the pores should not
become plugged so that the rate of filtration becomes too slow. The filter medium must allow the filter
cake to be removed easily and cleanly. Obviously, it must have sufficient strength not to tear and must be
chemically resistant to the solutions used.

Some widely used filter media are twill or duckweave heavy cloth, other types of woven heavy cloth,
woolen cloth, glass cloth, paper, felted pads of cellulose, metal cloth, nylon cloth, dacron cloth, and other
synthetic cloths. The ragged fibers of natural materials are more effective in removing fine particles than
the smooth plastic or metal fibers. Sometimes the filtrate may come through somewhat cloudy at first
before the first layers of particles, which help filter the subsequent slurry, are deposited. This filtrate can
be recycled for refiltration.

2. Filt er  a id s

Certain filter aids may be used to aid filtration. These are often incompressible diatomaceous earth or
kieselguhr, which is composed primarily of silica. Also used are wood cellulose and other inert porous
solids.

These filter aids can be used in a number of ways. They can be used as a precoat before the slurry is
filtered. This will prevent gelatinous-type solids from plugging the filter medium and also give a clearer
filtrate. They can also be added to the slurry before filtration. This increases the porosity of the cake and
reduces resistance of the cake during filtration. In a rotary filter, the filter aid may be applied as a
precoat; subsequently, thin slices of this layer are sliced off with the cake.

The use of filter aids is usually limited to cases where the cake is discarded or where the precipitate can be
separated chemically from the filter aid.

14 .2D. Basic The or y of Filtr ation

1. Pr essu r e d r op  of flu id  t hr ou g h filt er  ca k e

Figure 14.2-6 is a section through a filter cake and filter medium at a definite time t s from the start of the
flow of filtrate. At this time the thickness of the cake is L m (ft). The filter cross-sectional area is A m2
(ft 2), and the linear velocity of the filtrate in the L direction is ν m/s (ft/s) based on the filter area A m2.
Figure 14.2-6. Section through a filter cake.

The flow of the filtrate through the packed bed of cake can be described by an equation similar to
Poiseuille's law, assuming laminar flow occurs in the filter channels. Equation (2.10-2) gives Poiseuille's
equation for laminar flow in a straight tube, which can be written

Equation 14.2-1

where Δp is pressure drop in N/m2 (lbf/ft 2), ν is open-tube velocity in m/s (ft/s), D is diameter in m (ft),

L is length in m (ft), μ is viscosity in Pa · s or kg/m · s (lbm/ft · s), and g c is 32.174 lbm · ft/lbf · s2.

For laminar flow in a packed bed of particles, the Carman–Kozeny relation, which is similar to Eq.
(14.2-1) and to the Blake–Kozeny equation (3.1-17), has been shown to apply to filtration:

Equation 14.2-2

where k1 is a constant and equals 4.17 for random particles of definite size and shape, μ is viscosity of
filtrate in Pa · s (lbm/ft · s), ν is linear velocity based on filter area in m/s (ft/s), ε is void fraction or

porosity of cake, L is thickness of cake in m (ft), S0 is specific surface area of particle in m2 (ft 2) of particle

area per m3 (ft 3) volume of solid particle, and Δpc is pressure drop in the cake in N/m2 (lbf/ft 2). For


English units, the right-hand side of Eq. (14.2-2) is divided by g c. The linear velocity is based on the
empty cross-sectional area and is

Equation 14.2-3
where A is filter area in m2 (ft 2) and V is total m3 (ft 3) of filtrate collected up to time t s. The cake
thickness L may be related to the volume of filtrate V by a material balance. If cS is kg solids/m3 (lbm/ft 3)
of filtrate, a material balance gives

Equation 14.2-4

where ρp is density of solid particles in the cake in kg/m3 (lbm/ft 3) solid. The final term of Eq. (14.2-4) is
the volume of filtrate held in the cake. This is usually small and will beneglected.

Substituting Eq. (14.2-3) into (14.2-2) and using Eq. (14.2-4) to eliminate L, we obtain the final equation
as

Equation 14.2-5

where α is the specific cake resistance in m/kg(ft/lbm), defined as

Equation 14.2-6

For the filter-medium resistance, we can write, by analogy with Eq. (14.2-5),

Equation 14.2-7

where Rm is the resistance of the filter medium to filtrate flow in m−1 (ft −1) and Δpf is the pressure drop.
When Rm is treated as an empirical constant, it includes the resistance to flow of the piping leads to and
from the filter and the filter medium resistance.

Since the resistances of the cake and the filter medium are in series, Eqs. (14.2-5) and (14.2-7) can be
combined, and become
Equation 14.2-8

where Δp = Δpc + Δpf. Sometimes Eq. (14.2-8) is modified as follows:

Equation 14.2-9

where Ve is a volume of filtrate necessary to build up a fictitious filter cake whose resistance is equal to
Rm.

The volume of filtrate V can also be related to W, the kg of accumulated dry cake solids, as follows:

Equation 14.2-10

where cx is mass fraction of solids in the slurry, m is mass ratio of wet cake to dry cake, and ρ is density of

filtrate in kg/m3 (lbm/ft 3).

2. S p ecific ca k e r esist a nce

From Eq. (14.2-6) we see that the specific cake resistance is a function of void fraction ε and S0. It is also
a function of pressure, since pressure can affect ε. By conducting constant-pressure experiments at
various pressure drops, the variation of α with −Δp can be determined.

Alternatively, compression–permeability experiments can be performed. A filter cake at a low pressure
drop and atm pressure is built up by gravity filtering in a cylinder with a porous bottom. A piston is
loaded on top and the cake compressed to a given pressure. Then filtrate is fed to the cake and α is
determined by a differential form of Eq. (14.2-9). This is then repeated for other compression pressures
(G1).

If α is independent of −Δp, the sludge is incompressible. Usually, α increases with −Δp, since most cakes
are somewhat compressible. An empirical equation often used is

Equation 14.2-11

where α0 and s are empirical constants. The compressibility constant s is zero for incompressible sludges
or cakes. The constant s usually falls between 0.1 to 0.8. Sometimes the following is used:

Equation 14.2-12

where  , β,and s' are empirical constants. Experimental data for various sludges are given by Grace
(G1).

The data obtained from filtration experiments often do not have a high degree of reproducibility. The
state of agglomeration of the particles in the slurry can vary and have an effect on the specific cake
resistance.

14 .2E. Filtr ation Eq u ations for  C onstant-Pr e ssu r e  Filtr ation

1. Ba sic eq u a t ions for  filt r a t ion r a t e in b a t ch p r ocess

Often a filtration is done under conditions of constant pressure. Equation (14.2-8) can be inverted and
rearranged to give

Equation 14.2-13

where Kp is in s/m6 (s/ft 6) and B in s/m3 (s/ft 3):

Equation 14.2-14

Equation 14.2-15

For constant pressure, constant α, and incompressible cake, V and t are the only variables in Eq. (14.2-
13). Integrating to obtain the time of filtration in t s,
Equation 14.2-16

Equation 14.2-17

Dividing by V

Equation 14.2-18

where V is total volume of filtrate in m3 (ft 3) collected to t s.

To evaluate Eq. (14.2-17) it is necessary to know α and Rm. This can be done by using Eq. (14.2-18). Data
for V collected at different times t are obtained. Then the experimental data are plotted as t/V versus V,
as in Fig. 14.2-7 Often, the first point on the graph does not fall on the line and is omitted. The slope of
the line is Kp/2 and the intercept B. Then, using Eqs. (14.2-14) and (14.2-15), values of α and Rm can be
determined.

Figure 14.2-7. Determination of constants in a constant-pressure filtration run.

EXAMPLE 14.2-1. Evaluation of Filtration Constants for
Constant-Pressure Filtration
Data for the laboratory filtration of CaCO3 slurry in water at 298.2 K (25°C are reported as
follows at a constant pressure (−Δp) of 338 kN/m2 (7060 lbf/ft 2) (R1, R2, M1). The filter area

of the plate-and-frame press was A = 0.0439 m2 (0.473 ft 2) and the slurry concentration was
cs = 23.47 kg/m3 (1.465 lbm/ft 3). Calculate the constants α and Rm from the experimental

data given, where t is time in s and V is filtrate volume collected in m3.

t V t V t V

4.4 0.498 × 10−3 34.7 2.498 × 10−3 73.6 4.004 × 10−3

9.5 1.000 × 10−3 46.1 3.002 × 10−3 89.4 4.502 × 10−3

16.3 1.501 × 10−3 59.0 3.506 × 10−3 107.3 5.009 × 10−3

24.6 2.000 × 10−3        

S olu t ion: First, the data are calculated as t/V and tabulated in Table 14.2-1. The data are
plotted as t/V versus V in Fig. 14.2-8 and the intercept is determined as B = 6400 s/m3 (181
s/ft 3) and the slope as Kp/2 = 3.00 × 106 s/m6. Hence, Kp = 6.00 × 106 s/m6 (4820 s/ft 6).

Table 14.2-1. Values of t/V for Example 14.2-1 (t =s, V = m 3 )

t V ×σ103 (t/V) ×10−3

0 0  
4.4 0.498 8.84

9.5 1.000 9.50

16.3 1.501 10.86

24.6 2.000 12.30

34.7 2.498 13.89


46.1 3.002 15.36

59.0 3.506 16.83

73.6 4.004 18.38


89.4 4.502 19.86

107.3 5.009 21.42

Figure 14.2-8. Determination of constants for Example 14.2-1.
At 298.2 K the viscosity of water is 8.937 × 10−4 Pa ∊· s = 8.937 × 10−4 kg/ms. Substituting
known values into Eq. (14.2-14) and solving,

Substituting into Eq. (14.2-15) and solving,

EXAMPLE 14.2-2. Time Required to Perform a Filtration
The same slurry used in Example 14.2-1 is to be filtered in a plate-and-frame press having 20
frames and 0.873 m2 (9.4 ft 2) area per frame. The same pressure will be used in constant-
pressure filtration. Assuming the same filter-cake properties and filter cloth, calculate the time
to recover 3.37 m3 (119 ft 3) filtrate.

S olu t ion: In Example 14.2-1, the area A = 0.0439 m2, Kp = 6.00 × 106 s/m6, and B = 6400

s/m3. Since the α and Rm will be the same as before, Kp can be corrected. From Eq. (14.2-14),

Kp is proportional to 1/A2. The new area is A = 0.873(20) = 17.46 m2 (188 ft 2). The new Kp is
The new B is proportional to 1/A from Eq. (14.2-15):

Substituting into Eq. (14.2-17),

Using English units,

2. Eq u a t ions for  w a shing  of filt er  ca k es a nd  t ot a l cy cle t ime

The washing of a cake after the filtration cycle has been completed takes place by displacement of the
filtrate and by diffusion. The amount of wash liquid should be sufficient to give the desired washing
effect. To calculate washing rates, it is assumed that the conditions during washing are the same as those
that existed at the end of the filtration. It is assumed that the cake structure is not affected when wash
liquid replaces the slurry liquid in the cake.

In filters where the wash liquid follows a flow path similar to that during filtration, as in leaf filters, the
final filtering rate gives the predicted washing rate. For constant-pressure filtration, using the same
pressure in washing as in filtering, the final filtering rate is the reciprocal of Eq. (14.2-13):

Equation 14.2-19

where (dV/dt)f = rate of washing in m3/s (ft 3/s) and Vf is the total volume of filtrate for the entire period

at the end of filtration in m3 (ft 3).

For plate-and-frame filter presses, the wash liquid travels through a cake twice as thick and an area only
half as large as in filtering, so the predicted washing rate is one-fourth of the final filtration rate:

Equation 14.2-20
In actual experience the washing rate may be less than predicted because of cake consolidation,
channeling, and formation of cracks. Washing rates in a small plate-and-frame filter were found to be
from 70 to 92% of that predicted (M1).

After washing is completed, additional time is needed to remove the cake, clean the filter, and reassemble
the filter. The total filter-cycle time is the sum of the filtration time, plus the washing time, plus the
cleaning time.

EXAMPLE 14.2-3. Rate of Washing and Total Filter-Cycle
Time
At the end of the filtration cycle in Example 14.2-2, a total filtrate volume of 3.37 m3 is
collected in a total time of 269.7 s. The cake is to be washed by through-washing in the plate-
and-frame press using a volume of wash water equal to 10% of the filtrate volume. Calculate
the time of washing and the total filter-cycle time if cleaning the filter takes 20 min.

S olu t ion: For this filter, Eq. (14.2-20) holds. Substituting Kp = 37.93 s/m6, B = 16.10 s/m3,

and Vf = 3.37 m3, the washing rate is as follows:

The time of washing is then as follows for 0.10(3.37), or 0.337 m3 of wash water:

The total filtration cycle is

3. Eq u a t ions for  cont inu ou s filt r a t ion

In a filter that is continuous in operation, such as a rotary-drum vacuum type, the feed, filtrate, and cake
move at steady, continuous rates. In a rotary drum the pressure drop is held constant for the filtration.
The cake formation involves a continual change in conditions. In continuous filtration, the resistance of
the filter medium is generally negligible compared with the cake resistance. So in Eq. (14.2-13), B = 0.

Integrating Eq. (14.2-13), with B = 0,
Equation 14.2-21

Equation 14.2-22

where t is the time required for formation of the cake. In a rotary-drum filter, the filter time t is less than
the total cycle time t c by

Equation 14.2-23

where f is the fraction of the cycle used for cake formation. In the rotary drum, f is the fraction
submergence of the drum surface in the slurry.

Next, substituting Eq. (14.2-14) and Eq. (14.2-23) into (14.2-22) and rearranging,

Equation 14.2-24

If the specific cake resistance varies with pressure, the constants in Eq. (14.2-11) are needed to predict the
value of α to be used in Eq. (14.2-24). Experimental verification of Eq. (14.2-24) shows that the flow rate
varies inversely with the square root of the viscosity and the cycle time (N1).

When short cycle times are used in continuous filtration and/or the filter medium resistance is relatively
large, the filter resistance term B must be included, and Eq. (14.2-13) becomes

Equation 14.2-25

Then Eq. (14.2-25) becomes

Equation 14.2-26
EXAMPLE 14.2-4. Filtration in a Continuous Rotary-Drum
Filter
A rotary-vacuum-drum filter having a 33% submergence of the drum in the slurry is to be used
to filter a CaCO3 slurry as given in Example 14.2-1 using a pressure drop of 67.0 kPa. The
solids concentration in the slurry is cx = 0.191 kg solid/kg slurry and the filter cake is such that
the kg wet cake/kg dry cake = m = 2.0. The density and viscosity of the filtrate can be assumed
as those of water at 298.2 K. Calculate the filter area needed to filter 0.778 kg slurry/s. The
filter-cycle time is 250 s. The specific cake resistance can be represented by α = (4.37 × 109)
(−Δp)0.3, where −Δp is in Pa and α in m/kg.

S olu t ion: From Appendix A.2 for water, ρ = 996.9 kg/m3, μ = 0.8937 × 10−3 Pa · s. From Eq.
(14.2-10),

Solving for α, α = (4.37 × 109) (67.0 × 103)0.3 = 1.225 × 1011 m/kg. To calculate the flow rate of
the filtrate,

Substituting into Eq. (14.2-24), neglecting and setting B = 0, and solving,

Hence, A = 6.60 m2.

14 .2F. Filtr ation Eq u ations for  C onstant-R ate  Filtr ation

In some cases filtration runs are made under conditions of constant rate rather than constant pressure.
This occurs if the slurry is fed to the filter by a positive-displacement pump. Equation (14.2-8) can be
rearranged to give the following for a constant rate (dV/dt) m3/s:

Equation 14.2-27
where

Equation 14.2-28

Equation 14.2-29

KV is in N/m5 (lbf/ft 5) and C is in N/m2 (lbf/ft 2).

Assuming that the cake is incompressible, KV and C are constants characteristic of the slurry, cake, rate
of filtrate flow, and so on. Hence, a plot of pressure, −Δp, versus the total volume of filtrate collected, V,
gives a straight line for a constant rate dV/dt. The slope of the line is KV and the intercept is C. The
pressure increases as the cake thickness increases and the volume of filtrate collected increases.

The equations can also be rearranged in terms of −Δp and time t as variables. At any moment during the
filtration, the total volume V is related to the rate and total time t as follows:

Equation 14.2-30

Substituting Eq. (14.2-30) into Eq. (14.2-27),

Equation 14.2-31

For the case where the specific cake resistance α is not constant but varies as in Eq. (14.2-11), this can be
substituted for α in Eq. (14.2-27) to obtain a final equation.
                             
                                                 
                                             
                                               
     

14.3. SETTLING AND SEDIMENTATION IN PARTICLE–FLUID
SEPARATION

14 .3A. Intr od u ction

In filtration, the solid particles are removed from the slurry by forcing the fluid through a filter medium,
which blocks the passage of the solid particles and allows the filtrate to pass through. In settling and
sedimentation, the particles are separated from the fluid by gravitational forces acting on the particles.

Applications of settling and sedimentation include removal of solids from liquid sewage wastes, settling
of crystals from the mother liquor, separation of liquid–liquid mixture from a solvent-extraction stage in
a settler, settling of solid food particles from a liquid food, and settling of a slurry from a soybean
leaching process. The particles can be solid particles or liquid drops. The fluid can be a liquid or gas and
it may be at rest or in motion.

In some processes of settling and sedimentation, the purpose is to remove the particles from the fluid
stream so that the fluid is free of particle contaminants. In other processes, the particles are recovered as
the product, as in recovery of the dispersed phase in liquid–liquid extraction. In some cases the particles
are suspended in fluids so that the particles can be separated into fractions differing in size or in density.

When a particle is at a sufficient distance from the walls of the container and from other particles so that
its fall is not affected by them, the process is called free settling. Interference is less than 1% if the ratio of
the particle diameter to the container diameter is less than 1:200 or if the particle concentration is less
than 0.2 vol % in the solution. When the particles are crowded, they settle at a lower rate and the process
is called hindered settling. The separation of a dilute slurry or suspension by gravity settling into a clear
fluid and a slurry of higher solids content is called sedimentation.

14 .3B. The or y of Par ticle  M ov e m e nt Thr ou gh a Flu id

1. Der iv a t ion of b a sic eq u a t ions for  r ig id  sp he r es

Whenever a particle is moving through a fluid, a number of forces will be acting on the particle. First, a
density difference is needed between the particle and the fluid. An external force of gravity is needed to
impart motion to the particle. If the densities of the fluid and particle are equal, the buoyant force on the
particle will counterbalance the external force and the particle will not move relative to the fluid.

For a rigid particle moving in a fluid, there are three forces acting on the body: gravity acting downward,
buoyant force acting upward, and resistance or drag force acting in opposite direction to the particle
motion.

We will consider a particle of mass m kg falling at a velocity ν m/s relative to the fluid. The density of the
solid particle is ρp kg/m3 solid and that of the liquid is ρ kg/m3 liquid. The buoyant force Fb in N on the
particle is

Equation 14.3-1
where m/ρp is the volume Vp in m3 of the particle and g is the gravitational acceleration in m/s2.

The gravitation or external force Fg in N on the particle is

Equation 14.3-2

The drag force FD on a body in N may be derived from the fact that, as in flow of fluids, the drag force or

frictional resistance is proportional to the velocity head ν2/2 of the fluid displaced by the moving body.
This must be multiplied by the density of the fluid and by a significant area A, such as the projected area
of the particle. This was defined previously in Eq. (3.1-1):

Equation 14.3-3

where the drag coefficient C D is the proportionality constant and is dimensionless.

The resultant force on the body is then Fg − Fb − FD. This resultant force must equal the force due to
acceleration:

Equation 14.3-4

Substituting Eqs. (14.3-1)–(14.3-3) into (14.3-4),

Equation 14.3-5

If we start from the moment the body is released from its position of rest, the falling of the body consists
of two periods: the period of accelerated fall and the period of constant-velocity fall. The initial
acceleration period is usually very short, on the order of a tenth of a second or so. Hence, the period of
constant-velocity fall is the important one. The velocity is called the free settling velocity or terminal
velocity νt.

To solve for the terminal velocity in Eq. (14.3-5), dν/dt = 0 and the equation becomes
Equation 14.3-6

For spherical particles   and  . Substituting these into Eq. (14.3-6), we


obtain, for spherical particles,

Equation 14.3-7

where νt is m/s (ft/s), ρ is kg/m3 (lbm/ft 3), g is 9.80665 m/s2 (32.174 ft/s2), and Dp is m (ft).

2. Dr a g  coefficient  for  r ig id  sp her es

The drag coefficient for rigid spheres has been shown to be a function of the Reynolds number Dpνρ/μ of
the sphere and is shown in Fig. 14.3-1. In the laminar-ow region, called the Stokes' law region for NRe < 1,
as discussed in Section 3.1B, the drag coefficient is

Equation 14.3-8

Figure 14.3-1. Drag coefficient for a rigid sphere.
where μ is the viscosity of the liquid in Pa · s or kg/m · s (lbm/ft s). Substituting this into Eq. (14.3-7) for
laminar flow,

Equation 14.3-9

For other shapes of particles, drag coefficients will differ from those given in Fig. 14.3-1, and data are
given in Fig. 3.1-2 and elsewhere (B2, L2, P1). In the turbulent Newton's law region above a Reynolds
number of about 1000 to 2.0 × 105, the drag coefficient is approximately constant at C D = 0.44.

Solution of Eq. (14.3-7) is by trial and error when the particle diameter is known and the terminal
velocity is to be obtained, because C D also depends upon the velocity νt.

If the particles are quite small, Brownian motion is present. Brownian motion is the random motion
imparted to the particle by collisions between the molecules of the fluid surrounding the particle and the
particle. This movement of the particles in random directions tends to suppress the effect of gravity, so
settling of the particles may occur more slowly or not at all. At particle sizes of a few micrometers, the
Brownian effect becomes appreciable, and at sizes of less than 0.1 μm, the effect predominates. For very
small particles, application of centrifugal force helps reduce the effect of Brownian motion.

EXAMPLE 14.3-1. Settling Velocity of Oil Droplets
Oil droplets having a diameter of 20 μm (0.020 mm) are to be settled from air at temperature
of 37.8°C (311 K) and 101.3 kPa pressure. The density of the oil is 900 kg/m3. Calculate the
terminal settling velocity of the droplets.

S olu t ion: The various knowns are Dp = 2.0 × 10−5 m and ρp = 900 kg/m3. From Appendix
A.3, for air at 37.8°C, ρ = 1.137 kg/m3, μ = 1.90 × 10−5 Pa · s. The droplet will be assumed to be
a rigid sphere.

The solution is trial and error since the velocity is unknown. Hence, C D cannot be directly
determined. The Reynolds number is as follows:

Equation 14.3-10

For the first trial, assume that νt = 0.305 m/s. Then NRe = 1.197(0.305) = 0.365. Substituting
into Eq. (14.3-7) and solving for C D,

Equation 14.3-11

Using νt = 0.305 m/s, C D = 0.2067/(0.305)2 = 2.22.

Assuming that νt = 0.0305 m/s, NRe = 0.0365 from Eq. (14.3-10) and C D = 222 from Eq.
(14.3-11). For the third trial, assuming that νt = 0.00305 m/s, NRe = 0.00365 and C D = 22
200. These three values calculated for NRe and C D are plotted on a graph similar to Fig. 14.3-1
and shown in Fig. 14.3-2. It can be shown that the line through these points is a straight line.
The intersection of this line and the drag-coefficient correlation line is the solution to the
problem at NRe = 0.012. The velocity can be calculated from the Reynolds number in Eq. (14.3-
10):

Figure 14.3-2. Solution of Example 14.3-1 for settling velocity of a particle.
The particle is in the Reynolds number range less than 1, which is the laminar Stokes' law
region. Alternatively, the velocity can be calculated by substituting into Eq. (14.3-9):

Note that Eq. (14.3-9) could not be used until it was determined that the particle fall was in
the laminar region.

For particles that are rigid but nonspherical, the drag depends upon the shape of the particle and the
orientation of the particle with respect to its motion. Correlations of drag coefficients for particles of
different shapes are given in a number of references (B2, C1, P1).

3. Dr a g  coefficient s for  nonr ig id  sp her es

When particles are nonrigid, internal circulation inside the particle and particle deformation can occur.
Both of these effects affect the drag coefficient and terminal velocity. Drag coefficients for air bubbles
rising in water are given in Perry and Green (P1), and for a Reynolds number less than about 50, the curve
is the same as for rigid spheres in water.

For liquid drops in gases, the same drag relationship as for solid spherical particles is obtained up to a
Reynolds number of about 100 (H1). Large drops will deform with an increase in drag. Small liquid drops
in immiscible liquids behave like rigid spheres and the drag coefficient curve follows that for rigid spheres
up to a Reynolds number of about 10. Above this and up to a Reynolds number of 500, the terminal
velocity is greater than that for solids because of internal circulation in the drop.

14 .3C . Hind e r e d  S e ttling

For many cases of settling, a large number of particles are present, and the surrounding particles interfere
with the motion of individual particles. The velocity gradients surrounding each particle are affected by
the close presence of other particles. The particles settling in the liquid displace the liquid, and an
appreciable upward velocity of the liquid is generated. Hence, the velocity of the liquid is appreciably
greater with respect to the particle than with respect to the apparatus itself.
For such hindered flow, the settling velocity is less than would be calculated from Eq. (14.3-9) for Stokes'
law. The true drag force is greater in the suspension because of the interference of the other particles. This
higher effective viscosity of the mixture μm is equal to the actual viscosity of the liquid itself, μ, divided

by an empirical correction factor,  , which depends upon ε, the volume fraction of the slurry mixture
occupied by the liquid (S1):

Equation 14.3-12

where   is dimensionless and is as follows (S1):

Equation 14.3-13

The density of the fluid phase effectively becomes the bulk density of the slurry ρm, which is as follows:

Equation 14.3-14

where ρm is density of slurry in kg solid + liquid/m3. The density difference is now

Equation 14.3-15

The settling velocity, νt with respect to the apparatus is ε times the velocity calculated by Stokes' law.

Substituting mixture properties of μm from Eq. (14.3-12) for μ in Eq. (14.3-9), (ρp − ρm) from Eq. (14.3-
15) for (ρp − ρ), and multiplying the result by ε for the relative-velocity effect, Eq. (14.3-9) becomes, for
laminar settling,

Equation 14.3-16
This is the velocity calculated from Eq. (14.3-9), multiplied by the correction factor ( ).

The Reynolds number is then based on the velocity relative to the fluid and is

Equation 14.3-17

When the Reynolds number is less than 1, the settling is in the Stokes' law range. For Reynolds numbers
above 1.0, see (P1). The effect of concentration is greater for nonspherical particles and angular particles
(S1).

EXAMPLE 14.3-2. Hindered Settling of Glass Spheres
Calculate the settling velocity of glass spheres having a diameter of 1.554 × 10−4 m (5.10 ×
10−4 ft) in water at 293.2 K (20°C). The slurry contains 60 wt % solids. The density of the glass
spheres is ρp = 2467 kg/m3 (154 lbm/ft 3).

S olu t ion: Density of water ρ = 998 kg/m3 (62.3 lbm/ft 3), and viscosity of water μ = 1.005 ×

10−3 Pa · s (6.72 × 10−4 lbm/ft · s). To calculate the volume fraction ε of the liquid,

The bulk density of the slurry ρm according to Eq. (14.3-14) is

Substituting into Eq. (14.3-13),

Substituting into Eq. (14.3-16), using SI and English units,
The Reynolds number is obtained by substituting into Eq. (14.3-17):

Hence, the settling is in the laminar range.

14 .3D. W all Effe ct on Fr e e  S e ttling

When the diameter Dp of the particle becomes appreciable with respect to the diameter DW of the
container in which the settling is occurring, a retarding effect known as the wall effect is exerted on the
particle. The terminal settling velocity is reduced. In the case of settling in the Stokes' law regime, the
computed terminal velocity can be multiplied by the following to allow for the wall effect (Z1) for Dp/DW
< 0.05:

Equation 14.3-18

For a completely turbulent regime, the correction factor is

Equation 14.3-19

14 .3E. Diffe r e ntial S e ttling and  S e p ar ation of S olid s in C lassification

1. S ink -a nd -floa t  met hod s

Devices for the separation of solid particles into several fractions based upon their rates of flow or settling
through fluids are known as classifiers. There are several separation methods for accomplishing this,
namely, sink-and-float and differential settling. In the sink-and-float method, a liquid is used whose
density is intermediate between that of the heavy or high-density material and that of the light-density
material. In this liquid, the heavy particles will not float but settle out from the medium, while the light
particles will float.

This method is independent of the sizes of the particles and depends only upon the relative densities of
the two materials. This means liquids used must have densities greater than water, since most solids
have high densities. Unfortunately, few such liquids exist that are cheap and noncorrosive. As a result,
pseudoliquids are used, consisting of a suspension in water of very fine solid materials with high specific
gravities, such as galena (specific gravity = 7.5) and magnetite (specific gravity = 5.17).

Hindered settling is used and the bulk density of the medium can be varied widely by varying the
amount of the fine solid materials in the medium. Common applications of this technique are
concentrating ore materials and cleaning coal. The fine solid materials in the medium are so small in
diameter that their settling velocity is negligible, giving a relatively stable suspension.

2. Differ ent ia l set t ling  met hod s

The separation of solid particles into several size fractions based upon their settling velocities in a
particular medium is called differential settling or classification. The density of the medium is less than
that of either of the two substances to be separated.

In differential settling, both light and heavy materials settle through the medium. A disadvantage of this
method if the light and heavy materials both have a range of particle sizes is that the smaller heavy
particles settle at the same terminal velocity as the larger light particles.

Suppose that we consider two different materials: heavy-density material A (such as galena, with a
specific gravity ρA = 7.5) and light-density material B (such as quartz, with a specific gravity ρB = 2.65).
The terminal settling velocity of components A and B, from Eq. (14.3-7), can be written

Equation 14.3-20

Equation 14.3-21

For particles of equal settling velocities, νtA = νtB and we obtain, by equating Eq. (14.3-20) to (14.3-21),
canceling terms, and squaring both sides,

Equation 14.3-22
or

Equation 14.3-23

For particles that are essentially spheres at very high Reynolds numbers in the turbulent Newton's law
region, C D is constant and C DA = C DB, giving

Equation 14.3-24

For laminar Stokes' law settling,

Equation 14.3-25

Substituting Eq. (14.3-25) into (14.3-23) and rearranging for Stokes' law settling, where νtA = νtB,

Equation 14.3-26

For transition flow between laminar and turbulent flow,

Equation 14.3-27

For particles settling in the turbulent range, Eq. (14.3-24) holds for equal settling velocities. For particles
where DpA = DpB and settling is in the turbulent Newton's law region, combining Eqs. (14.3-20) and
(14.3-21),

Equation 14.3-28
If both A and B particles are settling in the same medium, then Eqs. (14.3-24) and (14.3-28) can be used
to make the plots given in Fig. 14.3-3 for the relation of velocity to diameter for A and B.

Figure 14.3-3. Settling and separation of two materials A and B in Newton's law region.

First, we consider a mixture of particles of materials A and B with a size range of Dp1 to Dp4 for both types
of material. In the size range Dp1 to Dp2 in Fig. 14.3-3, a pure fraction of substance B can be obtained,
since no particles of A settle as slowly. In the size range Dp3 to Dp4, a pure fraction of A can be obtained,
since no B particles settle as fast as the A particles in this size range. In the size range Dp1 to Dp3, A
particles settle as rapidly as B particles in the size range Dp2 to Dp4, forming a mixed fraction of A and B.

Increasing the density ρ of the medium in Eq. (14.3-24), the numerator becomes smaller proportionately
faster than the denominator, and the spread between DpA and DpB is increased. Somewhat similar curves
are obtained in the Stokes' law region.

EXAMPLE 14.3-3. Separation of a Mixture of Silica and
Galena
A mixture of silica (B) and galena (A) solid particles having a size range of 5.21 × 10−6 m to
2.50 × 10−5 m is to be separated by hydraulic classification using free settling conditions in
water at 293.2 K (B1). The specific gravity of silica is 2.65 and that of galena is 7.5. Calculate
the size range of the various fractions obtained in the settling. If the settling is in the laminar
region, the drag coefficients will be reasonably close to that for spheres.

S olu t ion: The particle-size range is Dp = 5.21 × 10−6 m to Dp = 2.50 × 10−5 m. Densities are

ρpA = 7.5(1000) = 7500 kg/m3, ρpB = 2.65(1000) = 2650 kg/m3, ρ = 998 kg/m3 for water at

293.2 K (20°C). The water viscosity μ = 1.005 × 10−3 Pa · s = 1.005 × 10−3 kg/ms.
Assuming Stokes' law settling, Eq. (14.3-9) becomes as follows:

Equation 14.3-29

The largest Reynolds number occurs for the largest particle and the biggest density, where DpA

= 2.50 × 10−5 m and ρpA = 7500. Substituting into Eq. (14.3-29),

Substituting into the Reynolds number equation,

Equation 14.3-30

Hence, the settling is in the Stokes' law region.

Referring to Fig. 14.3-3 and using the same nomenclature, the largest size is Dp4 = 2.50 × 10−5

m. The smallest size is Dp1 = 5.21 × 10−6 m. The pure fraction of A consists of DpA4 = 2.50 ×

10−5 m to DpA3. The particles, having diameters DpA3 and DpB4, are related by having equal

settling velocities in Eq. (14.3-26). Substituting DpB4 = 2.50 × 10−5 m into Eq. (14.3-26) and
solving,

The size range of pure B fraction is DpB2 to DpB1 = 5.21 × 10−6 m. The diameter DpB2 is related

to DpA1 = 5.21 × 10−6 by Eq. (14.3-26) at equal settling velocities:
The three fractions recovered are as follows:

1.  The size range of the first fraction of pure A (galena) is as follows:

2.  The mixed-fraction size range is as follows:

3.  The size range of the third fraction of pure B (silica) is as follows:

14 .3F. S e d im e ntation and  Thicke ning

1. M echa nisms of sed iment a t ion

When a dilute slurry is settled by gravity into a clear fluid and a slurry of higher solids concentration, the
process is called sedimentation or sometimes thickening. To illustrate the method for determining
settling velocities and the mechanisms of settling, a batch settling test is carried out by placing a uniform
concentration of the slurry in a graduated cylinder. At the start, as shown in Fig. 14.3-4a, all the particles
settle by free settling in suspension zone B. The particles in zone B settle at a uniform rate at the start,
and a clear liquid zone A appears in Fig. 14.3-4b. The height z drops at a constant rate. Also, zone D
begins to appear, which contains the settled particles at the bottom. Zone C is a transition layer whose
solids content varies from that in zone B to that in zone D. After further settling, zones B and C
disappear, as shown in Fig. 14.3-4c. Then compression first appears; this moment is called the critical
point. During compression, liquid is expelled upward from zone D and the thickness of zone D decreases.

Figure 14.3-4. Batch sedimentation results: (a) original uniform suspension, (b) zones of settling after a given
time, (c) compression of zone D after zones B and C disappear, (d) clear liquid interface height z versus time
of settling.
2. Det er mina t ion of set t ling  v elocit y

In Fig. 14.3-4d the height z of the clear-liquid interface is plotted versus time. As shown, the velocity of
settling, which is the slope of the line, is constant at first. The critical point is shown at point C. Since
sludges vary greatly in their settling rates, experimental rates for each sludge are necessary. Kynch (K1)
and Talmage and Fitch (T1) describe a method for predicting thickener sizes from the batch settling test.

The settling velocity ν is determined by drawing a tangent to the curve in Fig. 14.3-4d at a given time t 1,
with slope −dz/dt = ν1. At this point the height is z1, and zi is the intercept of the tangent to the curve.
Then,

Equation 14.3-31

The concentration c1 is, therefore, the average concentration of the suspension if zi is the height of this
slurry. This is calculated by

Equation 14.3-32

where c0 is the original slurry concentration in kg/m3 at z0 height and t = 0. This is repeated for other
times, and a plot of settling velocity versus concentration is made. Further details of this and other
methods of designing the thickener are given elsewhere (C1, F1, F2, T1, P1). These and other methods in
the literature are highly empirical and care should be exercised in their use.

14 .3G . Eq u ip m e nt for  S e ttling and  S e d im e ntation

1. S imp le g r a v it y  set t ling  t a nk


In Fig. 14.3-5a a simple gravity settler is shown for removing by settling a dispersed liquid phase from
another phase. The velocity horizontally to the right must be slow enough to allow time for the smallest
droplets to rise from the bottom to the interface or from the top down to the interface and coalesce.

Figure 14.3-5. Gravity settling tanks: (a) settler for liquid–liquid dispersion, (b) dust-settling chambers.

In Fig. 14.3-5b a gravity settling chamber is shown schematically. Dust-laden air enters at one end of a
large, boxlike chamber. Particles settle toward the floor at their terminal settling velocities. The air must
remain in the chamber a sufficient length of time (residence time) so that the particles reach the floor of
the chamber. Knowing the throughput of the air stream through the chamber and the chamber size, the
residence time of the air in the chamber can be calculated. The vertical height of the chamber must be
small enough that this height, divided by the settling velocity, gives a time less than the residence time
of the air.

2. Eq u ip ment  for  cla ssifica t ion

The simplest type of classifier is one in which a large tank is subdivided into several sections, as shown in
Fig. 14.3-6. A liquid slurry feed enters the tank containing a size range of solid particles. The larger,
faster-settling particles settle to the bottom close to the entrance and the slower-settling particles settle
to the bottom close to the exit. The linear velocity of the entering feed decreases as a result of the
enlargement of the cross-sectional area at the entrance. The vertical baffles in the tank allow for the
collection of several fractions. The settling-velocity equations derived in this section hold.

Figure 14.3-6. Simple gravity settling classifier.
3. S p it zk a st en cla ssifier

Another type of gravity settling chamber is the Spitzkasten, shown in Fig. 14.3-7, which consists of a
series of conical vessels of increasing diameter in the direction of flow. The slurry enters the first vessel,
where the largest and fastest-settling particles are separated. The overflow goes to the next vessel, where
another separation occurs. This continues in the succeeding vessel or vessels. In each vessel the velocity
of upflowing inlet water is controlled to give the desired size range for each vessel.

Figure 14.3-7. Spitzkasten gravity settling chamber.

4 . S ed iment a t ion t hick ener

The separation of a dilute slurry by gravity settling into a clear fluid and a slurry of higher solids
concentration is called sedimentation. Industrially, sedimentation operations are often carried out
continuously in equipment called thickeners. A continuous thickener with a slowly revolving rake for
removing the sludge or thickened slurry is shown in Fig. 14.3-8.

Figure 14.3-8. Continuous thickener.
[View full size image]

The slurry in Fig. 14.3-8 is fed at the center of the tank several feet below the surface of the liquid. Around
the top edge of the tank is a clear-liquid-overflow outlet. The rake serves to scrape the sludge toward the
center of the bottom for removal. This gentle stirring aids in removing water from the sludge.

In the thickener the entering slurry spreads radially through the cross section of the thickener and the
liquid flows upward and out the overflow. The solids settle in the upper zone by free settling. Below this
dilute settling zone is the transition zone, in which the concentration of solids increases rapidly, and
then the compression zone. A clear overflow can be obtained if the upward velocity of the fluid in the
dilute zone is less than the minimal terminal settling velocity of the solids in this zone.

The settling rates are quite slow in the thickened zone, which consists of a compression of the solids with
liquid being forced upward through the solids. This is an extreme case of hindered settling. Equation
(14.3-16) may be used to estimate the settling velocities, but the results can be in considerable error
because of agglomeration of particles. As a result, laboratory settling or sedimentation data must be used
in the design of a thickener, as discussed previously in Section 14.3F.
                             
                                                 
                                             
                                               
     

14.4. CENTRIFUGAL SEPARATION PROCESSES

14 .4 A. Intr od u ction

1. C ent r ifu g a l set t ling  or  sed iment a t ion

In Section 14.3 were discussed the processing methods of settling and sedimentation, where particles are
separated from a fluid by gravitational forces acting on the particles. The particles were solid, gas, or
liquid and the fluid was a liquid or a gas. In the present section we discuss settling or separation of
particles from a fluid by centrifugal forces acting on the particles.

Use of centrifuges increases the forces on particles manyfold. Hence, particles that will not settle readily
or at all in gravity settlers can often be separated from fluids by centrifugal force. The high settling force
means that practical rates of settling can be obtained with much smaller particles than in gravity
settlers. These high centrifugal forces do not change the relative settling velocities of small particles, but
these forces do overcome the disturbing effects of Brownian motion and free convection currents.

Sometimes gravity separation may be too slow because of the closeness of the densities of the particles
and the fluid, or because of association forces holding the components together, as in emulsions. An
example in the dairy industry is the separation of cream from whole milk, giving skim milk. Gravity
separation takes hours, while centrifugal separation is accomplished in minutes in a cream separator.
Centrifugal settling or separation is employed in many food industries, such as breweries, vegetable-oil
processing, fish-protein-concentrate processing, fruit juice processing to remove cellular materials, and
so on. Centrifugal separation is also used in drying crystals and for separating emulsions into their
constituent liquids or solid–liquid. The principles of centrifugal sedimentation are discussed in Sections
14.4B and 14.4C.

2. C ent r ifu g a l filt r a t ion

Centrifuges are also used in centrifugal filtration, where a centrifugal force is used instead of a pressure
difference to cause the flow of slurry in a filter where a cake of solids builds up on a screen. The cake of
granular solids from the slurry is deposited on a filter medium held in a rotating basket, washed, and
then spun “dry.” Centrifuges and ordinary filters are competitive in most solid–liquid separation
problems. The principles of centrifugal filtration are discussed in Section 14.4E.

14 .4 B. For ce s De v e lop e d  in C e ntr ifu gal S e p ar ation

1. Int r od u ct ion

Centrifugal separators make use of the common principle that an object whirled about an axis or center
point at a constant radial distance from the point is acted on by a force. The object being whirled about
an axis is constantly changing direction and is thus accelerating, even though the rotational speed is
constant. This centripetal force acts in a direction toward the center of rotation.

If the object being rotated is a cylindrical container, the contents of fluid and solids exert an equal and
opposite force, called centrifugal force, outward to the walls of the container. This is the force that causes
settling or sedimentation of particles through a layer of liquid or filtration of a liquid through a bed of
filter cake held inside a perforated rotating chamber.

In Fig. 14.4-1a a cylindrical bowl is shown rotating, with a slurry feed of solid particles and liquid being
admitted at the center. The feed enters and is immediately thrown outward to the walls of the container,
as in Fig. 14.4-1b. The liquid and solids are now acted upon by the vertical gravitational force and the
horizontal centrifugal force. The centrifugal force is usually so large that the force of gravity may be
neglected. The liquid layer then assumes the equilibrium position, with the surface almost vertical. The
particles settle horizontally outward and press against the vertical bowl wall.

Figure 14.4-1. Sketch of centrifugal separation: (a) initial slurry feed entering, (b) settling of solids from a
liquid, (c) separation of two liquid fractions.

In Fig. 14.4-1c two liquids having different densities are being separated by the centrifuge. The denser
fluid will occupy the outer periphery, since the centrifugal force on it is greater.

2. Eq u a t ions for  cent r ifu g a l for ce

In circular motion the acceleration due to the centrifugal force is

Equation 14.4-1

where a e is the acceleration from a centrifugal force in m/s2 (ft/s2), r is radial distance from the center of
rotation in m (ft), and ω is angular velocity in rad/s.

The centrifugal force Fc in N (lbf) acting on the particle is given by

Equation 14.4-2
where g c = 32.174 lbm · ft/lbfs2.

Since ω = ν/r, where ν is the tangential velocity of the particle in m/s (ft/s),

Equation 14.4-3

Often rotational speeds are given as N rev/min and

Equation 14.4-4

Equation 14.4-5

Substituting Eq. (14.4-4) into Eq. (14.4-2),

Equation 14.4-6

By Eq. (14.3-2), the gravitational force on a particle is

Equation 14.3-2

where g is the acceleration of gravity and is 9.80665 m/s2. In terms of gravitational force, the centrifugal
force is as follows, by combining Eqs. (14.3-2), (14.4-2), and (14.4-3):

Equation 14.4-7
Hence, the force developed in a centrifuge is rω 2/g or ν2/rg times as large as the gravitational force. This
is often expressed as equivalent to so many g forces.

EXAMPLE 14.4-1. Force in a Centrifuge
A centrifuge having a radius of the bowl of 0.1016 m (0.333 ft) is rotating at N = 1000 rev/min.

a.  Calculate the centrifugal force developed in terms of gravity forces.

b.  Compare this force to that for a bowl with a radius of 0.2032 m rotating at the same
rev/min.

S olu t ion: For part (a), r = 0.1016 m and N = 1000. Substituting into Eq. (14.4-7),

For part (b), r = 0.2032 m. Substituting into Eq. (14.4-7),

14 .4 C . Eq u ations for  R ate s of S e ttling in C e ntr ifu ge s

1. G ener a l eq u a t ion for  set t ling

If a centrifuge is used for sedimentation (removal of particles by settling), a particle of a given size can be
removed from the liquid in the bowl if there is sufficient residence time of the particle in the bowl for the
particle to reach the wall. For a particle moving radially at its terminal settling velocity, the diameter of
the smallest particle which can be removed can be calculated.

In Fig. 14.4-2 a schematic of a tubular-bowl centrifuge is shown. The feed enters at the bottom, and it is
assumed that all the liquid moves upward at a uniform velocity, carrying solid particles with it. The
particle is assumed to be moving radially at its terminal settling velocity νt. The trajectory or path of the
particle is shown in Fig. 14.4-2. A particle of a given size is removed from the liquid if sufficient residence
time is available for the particle to reach the wall of the bowl, where it is held. The length of the bowl is b
m.

Figure 14.4-2. Particle settling in sedimenting tubular-bowl centrifuge.

At the end of the residence time of the particle in the fluid, the particle is at a distance r B m from the axis
of rotation. If r B < r 2, then the particle leaves the bowl with the fluid. If r B = r 2, it is deposited on the wall
of the bowl and effectively removed from the liquid.

For settling in the Stokes' law range, the terminal settling velocity at a radius r is obtained by
substituting Eq. (14.4-1) for the acceleration g into Eq. (14.3-9):

Equation 14.4-8

where νt is settling velocity in the radial direction in m/s, Dp is particle diameter in m, ρp is particle

density in kg/m3, ρ is liquid density in kg/m3, and μ is liquid viscosity in Pa · s. If hindered settling
occurs, the right-hand side of Eq. (14.4-8) is multiplied by the factor (ε2ψp) given in Eq. (14.3-16).

Since νt = dr/dt, then Eq. (14.4-8) becomes

Equation 14.4-9
Integrating between the limits r = r 1 at t = 0 and r = r 2 at t = t T,

Equation 14.4-10

The residence time t T is equal to the volume of liquid V m3 in the bowl divided by the feed volumetric flow

rate q in m3/s. The volume  . Substituting into Eq. (14.4-10) and solving for q,

Equation 14.4-11

Particles having diameters smaller than that calculated from Eq. (14.4-11) will not reach the wall of the
bowl and will go out with the exit liquid. Larger particles will reach the wall and be removed from the
liquid.

A cut point or critical diameter Dpc can be defined as the diameter of a particle that reaches half the
distance between r 1 and r 2. This particle moves a distance of half the liquid layer or (r 2 − r 1)/2 during the
time this particle is in the centrifuge. The integration is then between r = (r 1 + r 2)/2 at t = 0 and r = r 2 at
t = t T. Then we obtain

Equation 14.4-12

At this flow rate qc, particles with a diameter greater than Dpc will predominantly settle to the wall and
most smaller particles will remain in the liquid.

2. S p ecia l ca se for  set t ling

For the special case where the thickness of the liquid layer is small compared to the radius, Eq. (14.4-8)
can be written for a constant r ≅ r 2 and Dp = Dpc as follows:

Equation 14.4-13
The time of settling t T is then as follows for the critical Dpc case:

Equation 14.4-14

Substituting Eq. (14.4-13) into (14.4-14) and rearranging,

Equation 14.4-15

The volume V can be expressed as

Equation 14.4-16

Combining Eqs. (14.4-15) and (14.4-16),

Equation 14.4-17

The analysis above is somewhat simplified. The pattern of flow of the fluid is actually more complicated.
These equations can also be used for liquid–liquid systems where droplets of liquid migrate according to
the equations and coalesce in the other liquid phase.

EXAMPLE 14.4-2. Settling in a Centrifuge
A viscous solution containing particles with a density ρp = 1461 kg/m3 is to be clarified by

centrifugation. The solution density ρ = 801 kg/m3 and its viscosity is 100 cp. The centrifuge
has a bowl with r 2 = 0.02225 m, r 1 = 0.00716 m, and height b = 0.1970 m. Calculate the
critical particle diameter of the largest particles in the exit stream if N = 23 000 rev/min and
the flow rate q = 0.002832 m3/h.

S olu t ion: Using Eq. (14.4-4),
The bowl volume V is

Viscosity μ = 100 × 10−3 = 0.100 Pa · s = 0.100 kg/m · s. The flow rate qc is

Substituting into Eq. (14.4-12) and solving for Dpc,

Substituting into Eq. (14.4-13) to obtain νt and then calculating the Reynolds number, the
settling is in the Stokes' law range.

3. S ig ma  v a lu es a nd  sca le-u p  of cent r ifu g es

A useful physical characteristic of a tubular-bowl centrifuge can be derived by multiplying and dividing
Eq. (14.4-12) by 2g and then substituting Eq. (14.3-9) written for Dpc into Eq. (14.4-12) to obtain

Equation 14.4-18

where νt is the terminal settling velocity of the particle in a gravitational field and

Equation 14.4-19
where Σ is a physical characteristic of the centrifuge and not of the fluid–particle system being separated.
Using Eq. (14.4-17) for the special case of settling for a thin layer,

Equation 14.4-20

The value of Σ is really the area in m2 of a gravitational settler that will have the same sedimentation
characteristics as the centrifuge for the same feed rate. To scale up from a laboratory test of q1 and Σ1 to q2
(for νt1 = νt2),

Equation 14.4-21

This scale-up procedure is dependable for centrifuges of similar type and geometry and if the centrifugal
forces are within a factor of 2 from each other. If different configurations are involved, efficiency factors E
should be used, where q1/Σ1 E1 = q2/Σ2 E2. These efficiencies must be determined experimentally, and
values for different types of centrifuges are given elsewhere (F1, P1).

4 . S ep a r a t ion of liq u id s in a  cent r ifu g e

Liquid–liquid separations in which the liquids are immiscible but finely dispersed as in an emulsion are
common operations in the food and other industries. An example is the dairy industry, in which the
emulsion of milk is separated into skim milk and cream. In these liquid–liquid separations, the position
of the outlet overflow weir in the centrifuge is very important, not only in controlling the volumetric
holdup V in the centrifuge but also in determining whether a separation is actually made.

In Fig. 14.4-3, a tubular-bowl centrifuge is shown in which the centrifuge is separating two liquid phases,
one a heavy liquid with density ρH kg/m3 and the second a light liquid with density ρL. The distances
shown are as follows: r 1 is radius to surface of light liquid layer, r 2 is radius to liquid–liquid interface,
and r 4 is radius to surface of heavy liquid downstream.

Figure 14.4-3. Tubular bowl centrifuge for separating two liquid phases.
To locate the interface, a balance must be made of the pressures in the two layers. The force on the fluid at
distance r is, by Eq. (14.4-2),

Equation 14.4-2

The differential force across a thickness dr is

Equation 14.4-22

But,

Equation 14.4-23

where b is the height of the bowl in m and (2πrb) dr is the volume of fluid. Substituting Eq. (14.4-23) in
(14.4-22) and dividing both sides by the area A = 2πrb,

Equation 14.4-24
where P is pressure in N/m2 (lbf/ft 2).

Integrating Eq. (14.4-24) between r 1 and r 2,

Equation 14.4-25

Applying Eq. (14.4-25) to Fig. 14.4-3 and equating the pressure exerted by the light phase of thickness r 2
− r 1 to the pressure exerted by the heavy phase of thickness r 2 − r 4 at the liquid–liquid interface at r 2,

Equation 14.4-26

Solving for , the interface position,

Equation 14.4-27

The interface at r 2 must be located at a radius smaller than r 3 in Fig. 14.4-3.

EXAMPLE 14.4-3. Location of Interface in Centrifuge
In a vegetable-oil-refining process, an aqueous phase is being separated from the oil phase in a
centrifuge. The density of the oil is 919.5 kg/m3 and that of the aqueous phase is 980.3 kg/m3.
The radius r 1 for overflow of the light liquid has been set at 10.160 mm and the outlet for the
heavy liquid at 10.414 mm. Calculate the location of the interface in the centrifuge.

S olu t ion: The densities are ρL = 919.5 and ρH = 980.3 kg/m3. Substituting into Eq. (14.4-27)
and solving for r 2,

13.4 D. C e ntr ifu ge  Eq u ip m e nt for  S e d im e ntation


1. Tu b u la r  cent r ifu g e

A schematic of a tubular-bowl centrifuge is shown in Fig. 14.4-3. The bowl is tall and has a narrow
diameter, 100–150 mm. Such centrifuges, known as supercentrifuges, develop a force about 13 000
times the force of gravity. Some narrow centrifuges, having a diameter of 75 mm and very high speeds of
60 000 or so rev/min, are known as ultracentrifuges. These supercentrifuges are often used to separate
liquid–liquid emulsions.

2. Disk  b ow l cent r ifu g e

The disk bowl centrifuge shown in Fig. 14.4-4 is often used in liquid–liquid separations. The feed enters
the actual compartment at the bottom and travels upward through vertically spaced feed holes, filling
the spaces between the disks. The holes divide the vertical assembly into an inner section, where mostly
light liquid is present, and an outer section, where mainly heavy liquid is present. This dividing line is
similar to an interface in a tubular centrifuge.

Figure 14.4-4. Schematic of disk bowl centrifuge.

The heavy liquid flows beneath the underside of a disk to the periphery of the bowl. The light liquid flows
over the upper side of the disks and toward the inner outlet. Any small amount of heavy solids is thrown
to the outer wall. Periodic cleaning is required to remove solids deposited. Disk bowl centrifuges are used
in starch–gluten separation, concentration of rubber latex, and cream separation. Details are given
elsewhere (P1, L1).

14 .4 E. C e ntr ifu gal Filtr ation

1. Theor y  for  cent r ifu g a l filt r a t ion

Theoretical prediction of filtration rates in centrifugal filters have not been too successful. The filtration
in centrifuges is more complicated than for ordinary filtration using pressure differences, since the area
for flow and driving force increase with distance from the axis and the specific cake resistance may
change markedly. Centrifuges for filtering are generally selected by scale-up from tests on a similar-type
laboratory centrifuge using the slurry to be processed.

The theory of constant-pressure filtration discussed in Section 14.2E can be modified and used where
centrifugal force causes the flow instead of impressed pressure difference. The equation will be derived for
the case where a cake has already been deposited, as shown in Fig. 14.4-5. he inside radius of the basket
is r 2, r i is the inner radius of the face of the cake, and r 1 is the inner radius of the liquid surface. We will
assume that the cake is nearly incompressible so that an average value of α can be used for the cake. Also,
the flow is laminar. If we assume a thin cake in a large-diameter centrifuge, then the area A for flow is
approximately constant. The velocity of the liquid is

Equation 14.4-28

Figure 14.4-5. Physical arrangement for centrifugal filtration.

where q is the filtrate flow rate in m3/s and ν the velocity. Substituting Eq. (14.4-28) into (14.2-8),

Equation 14.4-29

where mc = cSV, mass of cake in kg deposited on the filter.

For a hydraulic head of dz m, the pressure drop is

Equation 14.4-30

In a centrifugal field, g is replaced by rω 2 from Eq. (14.4-1) and dz by dr. Then,
Equation 14.4-31

Integrating between r 1 and r 2,

Equation 14.4-32

Combining Eqs. (14.4-29) and (14.4-32) and solving for q,

Equation 14.4-33

For the case where the flow area A varies considerably with the radius, the following has been derived
(G1):

Equation 14.4-34

where A2 = 2πr 2b (area of filter medium),   (logarithmic cake area), and 

 (arithmetic mean cake area). This equation holds for a cake of a given mass at a given
time. It is not an integrated equation covering the whole filtration cycle.

2. Eq u ip ment  for  cent r ifu g a l filt r a t ion

In a centrifugal filter, slurry is fed continuously to a rotating basket which has a perforated wall and is
covered with a filter cloth. The cake builds up on the surface of the filter medium to the desired thickness.
hen, at the end of the filtration cycle, feed is stopped, and wash liquid is added or sprayed onto the cake.
hen the wash liquid is stopped and the cake is spun as dry as possible. he motor is then shut off or slowed
and the basked allowed to rotate while the solids are discharged by a scraper knife, so that the solids drop
through an opening in the basket floor. Finally, the filter medium is rinsed clean to complete the cycle.
Usually, the batch cycle is completely automated. Automatic batch centrifugals have basket sizes up to
about 1.2 m in diameter and usually rotate below 4000 rpm.

Continuous centrifugal filters are available with capacities up to about 25 000 kg solids/h.
Intermittently, the cake deposited on the filter medium is removed by being pushed toward the discharge
end by a pusher, which then retreats, allowing the cake to build up once more. As the cake is being
pushed, it passes through a wash region. The filtrate and wash liquid are kept separate by partitions in
the collector. Details of different types of centrifugal filters are available (P1).

14 .4 F. G as–S olid  C yclone  S e p ar ator s

1. Int r od u ct ion a nd  eq u ip ment

For separation of small solid particles or mist from gases, the most widely used type of equipment is the
cyclone separator, shown in Fig. 14.4-6. The cyclone consists of a vertical cylinder with a conical bottom.
The gas–solid particle mixture enters in a tangential inlet near the top. This gas–solid mixture enters in
a rotating motion, and the vortex formed develops centrifugal force, which throws the particles radially
toward the wall.

Figure 14.4-6. Gas–solid cyclone separator: (a) side view, (b) top view.

On entering, the air in the cyclone flows downward in a spiral or vortex adjacent to the wall. When the air
reaches near the bottom of the cone, it spirals upward in a smaller spiral in the center of the cone and
cylinder. Hence, a double vortex is present. The downward and upward spirals are in the same direction.

The particles are thrown toward the wall and fall downward, leaving out the bottom of the cone. A
cyclone is a settling device in which the outward force on the particles at high tangential velocities is
many times the force of gravity. Hence, cyclones accomplish much more effective separation than gravity
settling chambers.
The centrifugal force in a cyclone ranges from about 5 times gravity in large, low-velocity units to 2500
times gravity in small, high-resistance units. These devices are used often in many applications, such as
in spray-drying of foods, where the dried particles are removed by cyclones; in cleaning dust-laden air;
and in removing mist droplets from gases. Cyclones offer one of the least expensive means of gas–particle
separation. They are generally applicable in removing particles over 5 μm in diameter from gases. For
particles over 200 μm in size, gravity settling chambers are often used. Wet-scrubber cyclones are
sometimes used, where water is sprayed inside, helping to remove the solids.

2. Theor y  for  cy clone sep a r a t or s

It is assumed that particles on entering a cyclone quickly reach their terminal settling velocities. Particle
sizes are usually so small that Stokes' law is considered valid. For centrifugal motion, the terminal radial
velocity νtR is given by Eq. (14.4-8), with νtR being used for νt:

Equation 14.4-35

Since ω = νtan /r, where νtan  is tangential velocity of the particle at radius r, Eq. (14.4-35) becomes

Equation 14.4-36

where νt is the gravitational terminal settling velocity νt in Eq. (14.3-9).

The higher the terminal velocity νt, the greater the radial velocity νtR and the easier it should be to
“settle” the particle at the walls. However, the evaluation of the radial velocity is difficult, since it is a
function of gravitational terminal velocity, tangential velocity, and position radially and axially in the
cyclone. Hence, the following empirical equation is often used (S2):

Equation 14.4-37

where b1 and n are empirical constants.

3. Efficiency  of collect ion of cy clones

Smaller particles have smaller settling velocities according to Eq. (14.4-37) and do not have time to reach
the wall to be collected. Hence, they leave with the exit air in a cyclone. Larger particles are more readily
collected. The efficiency of separation for a given particle diameter is defined as the mass fraction of the
size particles that are collected.
A typical collection-efficiency plot for a cyclone shows that the efficiency rises rapidly with particle size.
The cut diameter Dpc is the diameter for which one-half of the mass of the entering particles is retained.
                             
                                                 
                                             
                                               
     

14.5. MECHANICAL SIZE REDUCTION

14 .5A. Intr od u ction

Many solid materials occur in sizes that are too large to be used and must be reduced. Often the solids are
reduced in size so that the separation of various ingredients can be carried out. In general, the terms
crushing and grinding are used to signify the subdividing of large solid particles into smaller particles.

In the food-processing industry, a large number of food products are subjected to size reduction. Roller
mills are used to grind wheat and rye to flour and to grind corn. Soybeans are rolled, pressed, and ground
to produce oil and flour. Hammer mills are often used to produce potato flour, tapioca, and other flours.
Sugar is ground to a finer product.

Grinding operations are very extensive in the ore-processing and cement industries. Copper ores, nickel
and cobalt ores, and iron ores, for example, are ground before chemical processing. Limestone, marble,
gypsum, and dolomite are ground to use as fillers in paper, paint, and rubber. Raw materials for the
cement industry, such as lime, alumina, and silica, are ground on a very large scale.

Solids may be reduced in size by a number of methods. Compression or crushing is generally used for
reduction of hard solids to coarse sizes. Impact gives coarse, medium, or fine sizes. Attrition or rubbing
yields fine products. Cutting is used to give definite sizes.

14 .5B. Par ticle -S ize  M e asu r e m e nt

The feed-to-size reduction processes and the product are defined in terms of the particle-size distribution.
One common way to plot particle sizes is to plot particle diameter (sieve opening in screen) in mm or μm
versus the cumulative percent retained at that size. (Openings for various screen sizes are given in
Appendix A.5.) Such a plot was given on arithmetic probability paper in Fig. 12.12-2.

Often the plot is made, instead, as the cumulative amount as percent smaller than the stated size versus
particle size, as shown in Fig. 14.5-1a. In Fig. 14.5-1b the same data are plotted as a particle-distribution
curve. The ordinate is obtained by taking the slopes of the 5-μm intervals of Fig. 14.5-1a and converting
to percent by weight per μm. Complete particle-size analysis is necessary for most comparisons and
calculations.

Figure 14.5-1. Particle-size-distr ibution curves: (a) cumulative percent versus particle size, (b) percent by
weight per μm versus particle size. (From R. H. Perry and C. H. Chilton, Chemical Engineers' Handbook, 5th
ed. New York: McGraw-Hill Book Company, 1973. With permission.)

[View full size image]
14 .5C . Ene r gy and  Pow e r  R e q u ir e d  in S ize  R e d u ction

1. Int r od u ct ion

In size reduction of solids, feed materials of solid are reduced to a smaller size by mechanical action. The
materials are fractured. The particles of feed are first distorted and strained by the action of the size-
reduction machine. This work to strain the particles is first stored temporarily in the solid as strain
energy. As additional force is added to the stressed particles, the strain energy exceeds a certain level,
and the material fractures into smaller pieces.

When the material fractures, new surface area is created. Each new unit area of surface requires a certain
amount of energy. Some of the energy added is used to create the new surface, but a large portion of it
appears as heat. The energy required for fracture is a complicated function of the type of material, size,
hardness, and other factors.

The magnitude of the mechanical force applied; the duration; the type of force, such as compression,
shear, and impact; and other factors affect the extent and efficiency of the size-reduction process. The
important factors in the size-reduction process are the amount of energy or power used and the particle
size and new surface formed.

2. Pow er  r eq u ir ed  in size r ed u ct ion

The various theories or laws proposed for predicting power requirements for size reduction of solids do
not apply well in practice. The most important ones will be discussed briefly. Part of the problem with the
theories is estimating the theoretical amount of energy required to fracture and create new surface area.
Approximate calculations give actual efficiencies of about 0.1 to 2%.

The theories derived depend upon the assumption that the energy E required to produce a change dX in a
particle of size X is a power function of X:

Equation 14.5-1

where X is size or diameter of particle in mm, and n and C are constants depending upon type and size of
material and type of machine.

Rittinger proposed a law which states that the work in crushing is proportional to the new surface
created. This leads to a value of n = 2 in Eq. (14.5-1), since area is proportional to length squared.
Integrating Eq. (14.5-1),

Equation 14.5-2

where X1 is mean diameter of feed and X2 is mean diameter of product. Since n = 2 for Rittinger's
equation, we obtain

Equation 14.5-3

where E is work to reduce a unit mass of feed from X1 to X2 and KR is a constant. The law implies that the
same amount of energy is needed to reduce a material from 100 mm to 50 mm as is needed to reduce the
same material from 50 mm to 33.3 mm. It has been found experimentally that this law has some validity
in grinding fine powders.

Kick assumed that the energy required to reduce a material in size was directly proportional to the size-
reduction ratio. This implies n = 1 in Eq. (14.5-1), giving

Equation 14.5-4

where KK is a constant. This law implies that the same amount of energy is required to reduce a material
from 100 mm to 50 mm as is needed to reduce the same material from 50 mm to 25 mm.

Recent data by Bond (B3) on correlating extensive experimental data suggest that the work required
using a large-size feed is proportional to the square root of the surface/volume ratio of the product. This
corresponds to n = 1.5 in Eq. (14.5-1), giving

Equation 14.5-5

where KB is a constant. To use Eq. (14.4-5), Bond proposed a work index Ei as the work in kW · h/ton
required to reduce a unit weight from a very large size to 80% passing a 100-μm screen. Then the work E
is the gross work required to reduce a unit weight of feed with 80% passing a diameter XF μm to a
product with 80% passing XP μm.

Bond's final equation, in terms of English units, is

Equation 14.5-6

where P is hp, T is feed rate in tons/min, DF is size of feed in ft, and DP is product size in ft. Typical
values of Ei for various types of materials are given in Perry and Green (P1) and by Bond (B3). Some
typical values are bauxite (Ei = 9.45), coal (11.37), potash salt (8.23), shale (16.4), and granite (14.39).
These values should be multiplied by 1.34 for dry grinding.

EXAMPLE 14.5-1. Power to Crush Iron Ore by Bond's
Theory
It is desired to crush 10 ton/h of iron ore hematite. The size of the feed is such that 80% passes

a 3-in. (76.2-mm) screen and 80% of the product is to pass a   -in. (3.175-mm) screen.
Calculate the gross power required. Use a work index Ei for iron ore hematite of 12.68 (P1).

S olu t ion: The feed size is DF =   = 0.250 ft (76.2 mm) and the product size is DP =  /12 =


0.0104 ft (3.175 mm). The feed rate is T = 10/60 = 0.167 ton/min. Substituting into Eq. (14.5-
6) and solving for P,

14 .5D. Eq u ip m e nt for  S ize  R e d u ction

1. Int r od u ct ion a nd  cla ssifica t ion

Size-reduction equipment may be classified according to the way the forces are applied as follows:
between two surfaces, as in crushing and shearing; at one solid surface, as in impact; and by action of the
surrounding medium, as in a colloid mill. A more practical classification is to divide the equipment into
crushers, grinders, fine grinders, and cutters.

2. Ja w  cr u sher s

Equipment for coarse reduction of large amounts of solids consists of slow-speed machines called
crushers. Several types are in common use. In the first type, a jaw crusher, the material is fed between
two heavy jaws or flat plates. As shown in the Dodge crusher in Fig. 14.5-2a, one jaw is fixed and the
other reciprocating and movable on a pivot point at the bottom. The jaw swings back and forth, pivoting
at the bottom of the V. The material is gradually worked down into a narrower space, being crushed as it
moves.

Figure 14.5-2. Types of jaw crushers: (a) Dodge type, (b) Blake type.

The Blake crusher in Fig. 14.5-2b is more commonly used, where the pivot point is at the top of the
movable jaw. The reduction ratios average about 8:1 in the Blake crusher. Jaw crushers are used mainly
for primary crushing of hard materials and are usually followed by other types of crushers.

3. G y r a t or y  cr u sher s

The gyratory crusher shown in Fig. 14.5-3a has to a large extent taken over in the field of large hard-ore
and mineral crushing applications. Basically it is like a mortar-and-pestle crusher. The movable
crushing head is shaped like an inverted truncated cone and is inside a truncated cone casing. The
crushing head rotates eccentrically and the material being crushed is trapped between the outer fixed
cone and the inner gyrating cone.

Figure 14.5-3. Types of size-reduction equipment: (a) gyratory crusher, (b) roll crusher.
4 . R oll cr u sher s

In Fig. 14.5-3b a typical smooth roll crusher is shown. The rolls are rotated toward each other at the
same or different speeds. Wear of the rolls is a serious problem. The reduction ratio varies from about 4:1
to 2.5:1. Single rolls are often used, rotating against a fixed surface, and corrugated and toothed rolls are
also used. Many food products that are not hard materials, such as flour, soybeans, and starch, are
ground on rolls.

5. Ha mmer  mill g r ind er s

Hammer mill devices are used to reduce intermediate-sized material to small sizes or powder. Often the
product from jaw and gyratory crushers is the feed to the hammer mill. In the hammer mill a high-speed
rotor turns inside a cylindrical casing. Sets of hammers are attached to pivot points at the outside of the
rotor. The feed enters the top of the casing and the particles are broken as they fall through the cylinder.
The material is broken by the impact of the hammers and pulverized into powder between the hammers
and casing. The powder then passes through a grate or screen at the discharge end.

6 . R ev olv ing  g r ind ing  mills

For intermediate and fine reduction of materials, revolving grinding mills are often used. In such mills a
cylindrical or conical shell rotating on a horizontal axis is charged with a grinding medium such as steel,
flint, or porcelain balls, or with steel rods. The size reduction is effected by the tumbling of the balls or
rods on the material between them. In the revolving mill, the grinding elements are carried up the side of
the shell and fall on the particles underneath. These mills may operate wet or dry.

Equipment for very fine grinding is highly specialized. In some cases two flat disks are used, where one or
both disks rotate and grind the material caught between the disks (P1).
                             
                                                 
                                             
                                               
     

PROBLEMS
14 .2-1.
C onst a nt -Pr essu r e Filt r a t ion a nd  Filt r a t ion C onst a nt s. Data for the filtration of CaCO3
slurry in water at 298.2 K (25°C) are reported as follows (R1, R2, M1) at a constant pressure
(−Δp) of 46.2 kN/m2 (6.70 psia). The area of the plate-and-frame press was 0.0439 m2 (0.473
ft 2) and the slurry concentration was 23.47 kg solid/m3 filtrate. Calculate the constants α and
Rm. Data are given as t = time in s and V = volume of filtrate collected in m3.

V × 103 t V × 103 t V × 103 t

0.5 17.3 1.5 72.0 2.5 152.0

1.0 41.3 2.0 108.3 3.0 201.7

A1: Ans.  α = 1.106 × 1011 m/kg (1.65 × 1011 ft/lb ), R  = 6.40 × 1010 m−1 (1.95 × 1010 ft −1)


m m
14 .2-2.
Filt r a t ion C onst a nt s for  C onst a nt s-Pr essu r e Filt r a t ion. Data for constant-pressure
filtration at 194.4 kN/m2 are reported for the same slurry and press as in Problem 14.2-1 as
follows, where t is in s and V in m3:

V × 103 t V × 103 T V × 103 t

0.5 6.3 2.5 51.7 4.5 134.0

1.0 14.0 3.0 69.0 5.0 160.0

1.5 24.2 3.5 88.8    


2.0 37.0 4.0 110.0    

Q3:Calculate the constants α and Rm.
A3: Ans.  α = 1.61 × 1011 m/kg
14 .2-3.
C omp r essib ilit y  of Filt er  C a k e. Use the data for specific cake resistance α from Example
14.2-1 and Problems 14.2-1 and 14.2-2 and determine the compressibility constant s in Eq.
(14.2-11). Plot ln α versus ln(−Δp) and determine the slope s.
14 .2-4 .
Pr ed ict ion of Filt r a t ion Time a nd  W a shi ng  Time. The slurry used in Problem 14.2-1 is to
be filtered in a plate-and-frame press having 30 frames and 0.873 m2 area per frame. The same
pressure, 46.2 kN/m2, will be used in constant-pressure filtration. Assume the same filter-cake
properties and filter cloth, and calculate the time to recover 2.26 m3 of filtrate. At the end, using
through-washing and 0.283 m3 of wash water, calculate the time of washing and the total filter-
cycle time if cleaning the press takes 30 min.
14 .2-5.C onst a nt s in C onst a nt -Pr essu r e Filt r a t ion. McMillen and Webber (M2), using a filter
press with an area of 0.0929 m2, performed constant-pressure filtration at 34.5 kPa of a 13.9 wt
% CaCO3 solids in water slurry at 300 K. The mass ratio of wet cake to dry cake was 1.59. The

dry-cake density was 1017 kg/m3. The data obtained are as follows, where W = kg filtrate and t =
time in s:

W t W t W t

0.91 24 3.63 244 6.35 690


1.81 71 4.54 372 7.26 888

2.72 146 5.44 524 8.16 1188

Calculate the values of α and Rm.

14 .2-6 .
C onst a nt -Pr essu r e Filt r a t ion a nd  W a shing  in a  Lea f Filt er . An experimental filter
press having an area of 0.0414 m2 (R1) is used to filter an aqueous BaCO3 slurry at a constant
pressure of 267 kPa. The filtration equation obtained was

where t  is in s and V in m3.

a.  If the same slurry and conditions are used in a leaf press having an area of 6.97 m2, how
long will it take to obtain 1.00 m3 of filtrate?

b.  After filtration, the cake is to be washed with 0.100 m3 of water. Calculate the time of
washing.

A7:Ans. (a) t = 381.8 s
14 .2-7.
C onst a nt -R a t e Filt r a t ion of Incomp r essib le C a k e. The filtration equation for filtration at
a constant pressure of 38.7 psia (266.8 kPa) is

where t is in s, −Δp in psia, and V in liters. The specific resistance of the cake is independent of
pressure. If the filtration is run at a constant rate of 10 liters/s, how long will it take to reach 50
psia?
14 .2-8.
Effect  of Filt er -M ed iu m R esist a nce on C ont inu ou s R ot a r y -Dr u m Filt er . Repeat
Example 14.2-4 for the continuous rotary-drum vacuum filter but do not neglect the constant
Rm, which is the filter-medium resistance to flow. Compare with results of Example 14.2-4.
A9 : Ans.  A = 7.78 m2
14 .2-9 .Thr ou g hp u t  in C ont inu ou s R ot a r y -Dr u m Filt er . A rotary-drum filter having an area of
2.20 m2 is to be used to filter the CaCO3 slurry given in Example 14.2-4. The drum has a 28%

submergence and the filter-cycle time is 300 s. A pressure drop of 62.0 kN/m2 is to be used.
Calculate the slurry feed rate in kg slurry/s for the following cases:

a.  Neglect the filter-medium resistance.

b.  Do not neglect the value of B.

14 .3-1.
S et t ling  Velocit y  of a  C offee-Ext r a ct  Pa r t icle. Solid spherical particles of coffee extract
(F1) from a dryer having a diameter of 400 μm are falling through air at a temperature of 422 K.
The density of the particles is 1030 kg/m3. Calculate the terminal settling velocity and the
distance of fall in 5 s. The pressure is 101.32 kPa.
A11:Ans. νt = 1.49 m/s, 7.45 m fall
14 .3-2.
Ter mina l S et t ling  Velocit y  of Du st  Pa r t icles. Calculate the terminal settling velocity of
dust particles having a diameter of 60 μm in air at 294.3 K and 101.32 kPa. The dust particles
can be considered spherical, with a density of 1280 kg/m3.
A12:Ans. νt = 0.1372 m/s
14 .3-3.
S et t ling  Velocit y  of Liq u id  Pa r t icles. Oil droplets having a diameter of 200 μm are settling
from still air at 294.3 K and 101.32 kPa. The density of the oil is 900 kg/m3. A settling chamber
is 0.457 m high. Calculate the terminal settling velocity. How long will it take the particles to
settle? (Note: If the Reynolds number is above about 100, the equations and form-drag
correlation for rigid spheres cannot be used.)
14 .3-4 .
S et t ling  Velocit y  of Qu a r t z Pa r t icles in W a t er . Solid quartz particles having a diameter of
1000 μm are settling from water at 294.3 K. The density of the spherical particles is 2650 kg/m3.
Calculate the terminal settling velocity of these particles.
14 .3-5.
Hind er ed  S et t ling  of S olid  Pa r t icles. Solid spherical particles having a diameter of 0.090
mm and a solid density of 2002 kg/m3 are settling in a solution of water at 26.7°C. The volume
fraction of the solids in the water is 0.45. Calculate the settling velocity and the Reynolds
number.
14 .3-6 .
S et t ling  of Qu a r t z Pa r t icles in Hind er ed  S et t ling . Particles of quartz having a diameter
of 0.127 mm and a specific gravity of 2.65 are settling in water at 293.2 K. The volume fraction of
the particles in the slurry mixture of quartz and water is 0.25. Calculate the hindered settling
velocity and the Reynolds number.
14 .3-7.
Densit y  Effect  on S et t ling  Velocit y  a nd  Dia met er . Calculate the terminal settling
velocity of a glass sphere 0.080 mm in diameter having a density of 2469 kg/m3 in air at 300 K
and 101.32 kPa. Also calculate the diameter of a sphalerite sphere having a specific gravity of
4.00 with the same terminal settling velocity.
14 .3-8.
Differ ent ia l S et t ling  of Pa r t icles. Repeat Example 14.3-3 for particles having a size range of
1.27 × 10−2 mm to 5.08 × 10−2 mm. Calculate the size range of the various fractions obtained
using free settling conditions. Also calculate the value of the largest Reynolds number occurring.
14 .3-9 .
S ep a r a t ion b y  S et t ling . A mixture of galena and silica particles has a size range of 0.075–
0.65 mm and is to be separated by a rising stream of water at 293.2 K. Use specific gravities from
Example 14.3-3.

a.  To obtain an uncontaminated product of galena, what velocity of water flow is needed
and what is the size range of the pure product?

b.  If another liquid, such as benzene, having a specific gravity of 0.85 and a viscosity of 6.50
× 10−4 Pa · s is used, what velocity is needed and what is the size range of the pure
product?

14 .3-
S ep a r a t ion b y  S ink -a nd -Floa t  M et hod . Quartz having a specific gravity of 2.65 and
10.
hematite having a specific gravity of 5.1 are present in a mixture of particles. It is desired to
separate them by a sink-and-oat method using a suspension of fine particles of ferrosilicon
having a specific gravity of 6.7 in water. At what consistency in vol % ferrosilicon solids in water
should the medium be maintained for the separation?
14 .3-
Ba t ch S et t ling  a nd  S ed iment a t ion Velocit ies. A batch settling test on a slurry gave the
11.
following results, where the height z in meters between the clear liquid and the suspended solids
is given at time t hours:

t (h) z (m) t (h) z (m) t (h) z (m)

0 0.360 1.75 0.150 12.0 0.102

0.50 0.285 3.00 0.125 20.0 0.090

1.00 0.211 5.00 0.113    

The original slurry concentration is 250 kg/m3 of slurry. Determine the velocities of settling and
concentrations and make a plot of velocity versus concentration.

14 .4 -1.
C omp a r ison of For ces in C ent r ifu g es. Two centrifuges rotate at the same peripheral
velocity of 53.34 m/s. The first bowl has a radius of r 1 = 76.2 mm and the second r 2 = 305 mm.
Calculate the rev/min and the centrifugal forces developed in each bowl.
A22:Ans. N1 = 6684 rev/min, N2 = 1670 rev/min, 3806 g's in bowl 1951 g's in bowl 2
14 .4 -2.
For ces in a  C ent r ifu g e. A centrifuge bowl is spinning at a constant 2000 rev/min. What
radius bowl is needed for the following?

a.  A force of 455 g's.

b.  A force four times that in part (a).

A23:Ans. (a) r = 0.1017 m
14 .4 -3.
Effect  of Va r y ing  C ent r ifu g e Dimensions a nd  S p eed . Repeat Example 14.4-2 but with
the following changes:

a.  Reduce the rev/min to 10 000 and double the outer-bowl radius r 2 to 0.0445 m, keeping


r 1 = 0.00716 m.
b.  Keep all variables as in Example 14.4-2 but double the throughput.

A24 : Ans.  (b) D  = 1.747 × 10−6 m


p
14 .4 -4 .
C ent r ifu g ing  t o R emov e Food  Pa r t icles. A dilute slurry contains small solid food particles
having a diameter of 5 × 10−2 mm which are to be removed by centrifuging. The particle density
is 1050 kg/m3 and the solution density is 1000 kg/m3. The viscosity of the liquid is 1.2 × 10−3 Pa
· s. A centrifuge at 3000 rev/min is to be used. The bowl dimensions are b = 100.1 mm, r 1 = 5.00

mm, and r 2 = 30.0 mm. Calculate the expected flow rate in m3/s just to remove these particles.
14 .4 -5.
Effect  of Oil Densit y  on Int er fa ce Loca t ion. Repeat Example 14.4-3, but for the case where
the vegetable-oil density has been decreased to 914.7 kg/m3.
14 .4 -6 .
Int er fa ce in C r ea m S ep a r a t or . A cream-separator centrifuge has an outlet discharge radius
r 1 = 50.8 mm and outlet radius r 4 = 76.2 mm. The density of the skim milk is 1032 kg/m3 and

that of the cream is 865 kg/m3 (E1). Calculate the radius of the interface neutral zone.
A27:Ans. r 2 = 150 mm
14 .4 -7.
S ca le-Up  a nd  Σ Va lu es of C ent r ifu g es. For the conditions given in Example 14.4-2, do as
follows:

a.  Calculate the Σ value.

b.  A new centrifuge having the following dimensions is to be used: r 2 = 0.0445 m, r 1 =


0.01432 m, b = 0.394 m, and N = 26 000 rev/min. Calculate the new Σ value and scale up
the flow rate using the same solution.

A28: Ans.  (a) Σ = 196.3 m2


14 .4 -8.
C ent r ifu g a l Filt r a t ion Pr ocess. A batch centrifugal filter similar to Fig. 14.4-5 has a bowl
height b = 0.457 m and r 2 = 0.381 m and operates at 33.33 rev/s at 25.0°C. The filtrate is
essentially water. At a given time in the cycle, the slurry and cake formed have the following
properties: cS = 60.0 kg solids/m3 filtrate, ε = 0.82, ρp = 2002 kg solids/m3, cake thickness =

0.152 m, α = 6.38 × 1010 m/kg, Rm = 8.53 × 1010 m−1, r 1 = 0.2032 m. Calculate the rate of
filtrate flow.
A29 : Ans.  q = 6.11 × 10−4 m3/s
14 .5-1.
C ha ng e in Pow er  R eq u ir ement s in C r u shing . In crushing a certain ore, the feed is such
that 80% is less than 50.8 mm in size, and the product size is such that 80% is less than 6.35
mm. The power required is 89.5 kW. What will be the power required using the same feed so that
80% is less than 3.18 mm? Use the Bond equation. (Hint: The work index Ei is unknown, but it
can be determined using the original experimental data in terms of T. In the equation for the new
size, the same unknowns appear. Dividing one equation by the other will eliminate these
unknowns.)
A30:Ans. 146.7 kW
14 .5-2.
C r u shing  of Phosp ha t e R ock . It is desired to crush 100 ton/h of phosphate rock from a feed
size where 80% is less than 4 in. to a product where 80% is less than   in. The work index is
10.13 (P1).

a.  Calculate the power required.

b.  Calculate the power required to crush the product further to where 80% is less than 1000
μm.
                             
                                                 
                                             
                                               
     

Appendix A.1. Fundamental Constants and Conversion
Factors
                             
                                                 
                                             
                                               
     

A.1­1. Gas Law Constant R
Numerical Value Units

1.9872 g cal/g mol · K
1.9872 btu/lb mol · °R
82.057 cm3  · atm/g mol · K

8314.34 J/kg mol · K

82.057 × 10−3 m3  · atm/kg mol · K

8314.34 kg · m2 /s2  · kg mol · K

10.731 ft3  · lb /in.2  · lb mol · °R


f

0.7302 ft3  · atm/lb mol · °R

1545.3 ft · lbf/lb mol · °R

8314.34 m3  · Pa/kg mol · K
                             
                                                 
                                             
                                               
     

A.1­2. Volume and Density
1 g mol ideal gas at 0°C, 760 mm Hg = 22.4140 liters = 22 414 cm3

1 lb mol ideal gas at 0°C, 760 mm Hg = 359.05 ft3

1 kg mol ideal gas at 0°C, 760 mm Hg = 22.414 m3

Density of dry air at 0°C, 760 mm Hg = 1.2929 g/liter
  = 0.080711 lb /ft3
m

Molecular weight of air = 28.97 lbm/lb mol = 28.97 g/g mol

1 g/cm3  = 62.43 lb /ft3  = 1000 kg/m3


m

1 g/cm3  = 8.345 lb /U.S. gal


m

1 lb /ft3  = 16.0185 kg/m3


m
                             
                                                 
                                             
                                               
     

A.1­3. Length

1 in. = 2.540 cm

100 cm = 1 m (meter)

1 micron = 10−6 m = 10−4 cm = 10−3 mm = 1 μm (micrometer)

1 Å (angstrom) = 10−10 m = 10−4 μm

1 mile = 5280 ft

1 m = 3.2808 ft = 39.37 in.
                             
                                                 
                                             
                                               
     

A.1­4. Mass

1 lbm = 453.59 g = 0.45359 kg

1 lbm = 16 oz = 7000 grains

1 kg = 1000 g = 2.2046 lbm

1 ton (short) = 2000 lbm

1 ton (long) = 2240 lbm

1 ton (metric) = 1000 kg
                             
                                                 
                                             
                                               
     

A.1­5. Standard Acceleration of Gravity
g = 9.80665 m/s2

g = 980.665 cm/s2

g = 32.174 ft/s2

gc (gravitational conversion factor) = 32.1740 lb  · ft/lb  · s2


m f

  = 980.665 g  · cm/g  · s2


m f
                             
                                                 
                                             
                                               
     

A.1­6. Volume
1 L (liter) = 1000 cm3 1 m3  = 1000 L (liter)

1 in.3  = 16.387 cm3 1 U.S. gal = 4 qt

1 ft3  = 28.317 L (liter) 1 U.S. gal = 3.7854 L (liter)

1 ft3  = 0.028317 m3 1 U.S. gal = 3785.4 cm3

1 ft3  = 7.481 U.S. gal 1 British gal = 1.20094 U.S. gal

1 m3  = 264.17 U.S. gal 1 m3  = 35.313 ft3


                             
                                                 
                                             
                                               
     

A.1­7. Force

1 g · cm/s2 (dyn) = 10−5 kg · m/s2 = 10−5 N (newton)

1 g · cm/s2 = 7.2330 × 10−5 lbm · ft/s2 (poundal)

1 kg · m/s2 = 1 N (newton)

1 lbf = 4.4482 N

1 g · cm/s2 = 2.2481 × 10−6 lbf
                             
                                                 
                                             
                                               
     

A.1­8. Pressure

1 bar = 1 × 105 Pa (pascal) = 1 × 105 N/m2

1 psia = 1 lbf/in. 2

1 psia = 2.0360 in. Hg at 0°C

1 psia = 2.311 ft H2O at 70°F

1 psia = 51.715 mm Hg at 0°C (ρHg = 13.5955 g/cm3)

1 atm = 14.696 psia = 1.01325 × 105 N/m2 = 1.01325 bar

1 atm = 760 mm Hg at 0°C = 1.01325 × 105 Pa = 1.01325 × 102 kPa

1 atm = 29.921 in. Hg at 0°C

1 atm = 33.90 ft H2O at 4°C

1 psia = 6.89476 × 104 g/cm · s2

1 psia = 6.89476 × 104 dyn/cm2

1 dyn/cm2 = 2.0886 × 10−3 lbf/ft 2

1 psia = 6.89476 × 103 N/m2 = 6.89476 × 103 Pa

1 lbf/ft 2 = 4.7880 × 102 dyn/cm2 = 47.880 N/m2

1 mm Hg (0°C) = 1.333224 × 102 N/m2 = 0.1333224 kPa
                             
                                                 
                                             
                                               
     

A.1­9. Power
1 hp = 0.74570 kW 1 watt (W) = 14.340 cal/min

1 hp = 550 ft · lbf/s 1 btu/h = 0.29307 W (watt)

1 hp = 0.7068 btu/s 1 J/s (joule/s) = 1 W
                             
                                                 
                                             
                                               
     

A.1­10. Heat, Energy, Work

1 J = 1 N · m = 1 kg · m2/s2

1 kg · m2/s2 = 1 J (joule) = 107  g · cm2/s2 (erg)

1 btu = 1055.06 J = 1.05506 kJ

1 btu = 252.16 cal (thermochemical)

1 kcal (thermochemical) = 1000 cal = 4.1840 kJ

1 cal (thermochemical) = 4.1840 J

1 cal (IT) = 4.1868 J

1 btu = 251.996 cal (IT)

1 btu = 778.17 ft · lbf

1 hp · h = 0.7457 kW · h

1 hp · h = 2544.5 btu

1 ft · lbf = 1.35582 J

1 ft · lbf/lbm = 2.9890 J/kg
                             
                                                 
                                             
                                               
     

A.1­11. Thermal Conductivity

1 btu/h · ft · °F = 4.1365 × 10−3 cal/s · cm · °C

1 btu/h · ft · °F = 1.73073 W/m · K
                             
                                                 
                                             
                                               
     

A.1­12. Heat­Transfer Coefficient

1 btu/h · ft 2 · °F = 1.3571 × 10−4 cal/s · cm2 · °C

1 btu/h · ft 2 · °F = 5.6783 × 10−4 W/cm2 · °C

1 btu/h · ft 2 · °F = 5.6783 W/m2 · K

1 kcal/h · m2 · °F = 0.2048 btu/h · ft 2 · °F
                             
                                                 
                                             
                                               
     

A.1­13. Viscosity

1 cp = 10−2 g/cm · s (poise)

1 cp = 2.4191 lbm/ft · h

1 cp = 6.7197 × 10−4 lbm/ft · s

1 cp = 10−3 Pa · s = 10−3 kg/m · s = 10−3 N · s/m2

1 cp = 2.0886 × 10−5 lbf · s/ft 2

1 Pa · s = 1 N · s/m2 = 1 kg/m · s = 1000 cp = 0.67197 lbm/ft · s
                             
                                                 
                                             
                                               
     

A.1­14. Diffusivity
1 cm2 /s = 3.875 ft2 /h 1 m2 /s = 3.875 × 104  ft2 /h

1 cm2 /s = 10−4  m2 /s 1 centistoke = 10−2  cm2 /s

1 m2 /h = 10.764 ft2 /h  
                             
                                                 
                                             
                                               
     

A.1­15. Mass Flux and Molar Flux

1 g/s · cm2 = 7.3734 × 103 lbm/h · ft 2

1 g mol/s · cm2 = 7.3734 × 103 lb mol/h · ft 2

1 g mol/s · cm2 = 10 kg mol/s · m2 = 1 × 104 g mol/s · m2

1 lb mol/h · ft 2 = 1.3562 × 10−3 kg mol/s · m2
                             
                                                 
                                             
                                               
     

A.1­16. Heat Flux and Heat Flow

1 btu/h · ft 2 = 3.1546 W/m2

1 btu/h = 0.29307 W

1 cal/h = 1.1622 × 10−3 W
                             
                                                 
                                             
                                               
     

A.1­17. Heat Capacity and Enthalpy

1 btu/lbm · °F = 4.1868 kJ/kg · K

1 btu/lbm · °F = 1.000 cal/g · °C

1 btu/lbm = 2326.0 J/kg

1 ft · lbf/lbm = 2.9890 J/kg

1 cal (IT)/g · °C = 4.1868 kJ/kg · K

1 kcal/g mol = 4.1840 × 103 kJ/kg mol
                             
                                                 
                                             
                                               
     

A.1­18. Mass­Transfer Coefficient

1 kc cm/s = 10−2 m/s

1 kc ft/h = 8.4668 × 10−5 m/s

1 kx g mol/s · cm2 · mol frac = 10 kg mol/s · m2 · mol frac

1 kx g mol/s · cm2 · mol frac = 1 × 104 g mol/s · m2 · mol frac

1 kx lb mol/h · ft 2 · mol frac = 1.3562 × 10−3 kg mol/s · m2 · mol frac

1 kxa lb mol/h · ft 3 · mol frac = 4.449 × 10−3 kg mol/s · m3 · mol frac

1 kG kg mol/s · m2 · atm = 0.98692 × 10−5 kg mol/s · m2 · Pa

1 kG a kg mol/s · m3 · atm = 0.98692 × 10−5 kg mol/s · m3 · Pa
                             
                                                 
                                             
                                               
     

A.1­19. Temperature

0°C = 32°F (freezing point of water)

1.0 K = 1.0°C = 1.8°F = 1.8°R (Rankine)

°F = 32 + 1.8 (°C)

°C = (1/1.8)(°F − 32)

°R = °F + 459.67

K = °C + 273.15

100°C = 212°F = 373.15 K = 671.67°R

0°C = 32°F = 273.15 K = 491.67°R

−273.15°C = −459.67°F = 0 K = 0°R (absolute zero)
                             
                                                 
                                             
                                               
     

Appendix A.2. Physical Properties of Water

A.2-1. Latent Heat of Water at 273.15 K (0°C)

Latent heat of fusion = 1436.3 cal/g mol
  = 79.724 cal/g
  = 2585.3 btu/lb mol

  = 6013.4 kJ/kg mol
Source: O. A. Hougen, K. M. Watson, and R. A. Ragatz, Chemical Process Principles, Part I, 2nd ed.
New York: John Wiley & Sons, Inc., 1954.

Latent heat of vaporization at 298.15 K (25°C)

Pressure (mm Hg) Latent Heat

23.75 44 020 kJ/kg mol, 10.514 kcal/g mol, 18 925
btu/lb mol

760 44 045 kJ/kg mol, 10.520 kcal/g mol, 18 936
btu/lb mol
Source: National Bureau of Standards, Circular 500.

A.2-2. Vapor Pressure of Water

Temperature Vapor Pressure Temperature Vapor Pressure

K °C Kpa mm Hg K °C kPa mm Hg

273.15 0 0.611 4.58 323.15 50 12.333 92.51


283.15 10 1.228 9.21 333.15 60 19.92 149.4

293.15 20 2.338 17.54 343.15 70 31.16 233.7


298.15 25 3.168 23.76 353.15 80 47.34 355.1
303.15 30 4.242 31.82 363.15 90 70.10 525.8

313.15 40 7.375 55.32 373.15 100 101.325 760.0


Source: Physikalish-technishe, Reichsansalt, Holborn, Scheel, and Henning, Warmetabellen.
Brunswick, Germany: Friedrich Viewig and Son, 1909.

A.2-3. Density  of Liquid Water

Temperature Density Temperature Density


K °C g/cm 3 kg/m 3 K °C g/cm 3 kg/m 3

273.15 0 0.99987 999.87 323.15 50 0.98807 988.07

277.15 4 1.00000 1000.00 333.15 60 0.98324 983.24

283.15 10 0.99973 999.73 343.15 70 0.97781 977.81


293.15 20 0.99823 998.23 353.15 80 0.97183 971.83

298.15 25 0.99708 997.08 363.15 90 0.96534 965.34


303.15 30 0.99568 995.68 373.15 100 0.95838 958.38
313.15 40 0.99225 992.25        
Source: R. H. Perry and C. H. Chilton, Chemical Engineers' Handbook, 5th ed. New York: McGraw-
Hill Book Company, 1973. With permission.

A.2-4. Viscosity  of Liquid Water

Temperature Viscosity  [(Pa · Temperature Viscosity , [(Pa ·


s)103 , (kg/m · s)103 , (kg/m · s)
K °C K °C
s) 103 , or cp] 103 , or cp]

273.15 0 1.7921 323.15 50 0.5494

275.15 2 1.6728 325.15 52 0.5315


277.15 4 1.5674 327.15 54 0.5146

279.15 6 1.4728 329.15 56 0.4985

281.15 8 1.3860 331.15 58 0.4832

283.15 10 1.3077 333.15 60 0.4688


285.15 12 1.2363 335.15 62 0.4550

287.15 14 1.1709 337.15 64 0.4418

289.15 16 1.1111 339.15 66 0.4293

291.15 18 1.0559 341.15 68 0.4174


293.15 20 1.0050 343.15 70 0.4061
293.35 20.2 1.0000 345.15 72 0.3952

295.15 22 0.9579 347.15 74 0.3849


297.15 24 0.9142 349.15 76 0.3750
298.15 25 0.8937 351.15 78 0.3655

299.15 26 0.8737 353.15 80 0.3565


301.15 28 0.8360 355.15 82 0.3478
303.15 30 0.8007 357.15 84 0.3395

305.15 32 0.7679 359.15 86 0.3315

307.15 34 0.7371 361.15 88 0.3239


309.15 36 0.7085 363.15 90 0.3165

311.15 38 0.6814 365.15 92 0.3095


313.15 40 0.6560 367.15 94 0.3027

315.15 42 0.6321 369.15 96 0.2962


317.15 44 0.6097 371.15 98 0.2899

319 15 46 0 5883 373 15 100 0 2838


319.15 46 0.5883 373.15 100 0.2838
321.15 48 0.5683      
Source: Bingham, Fluidity and Plasticity. New York: McGraw-Hill Book Company, 1922. With
permission.

A.2-5. Heat Capacity of Liquid Water at 101.325 kPa (1 Atm)

Temperature Heat Capacity, c p Temperature Heat Capacity, c p

°C K cal/g · °C kJ/kg · K °C K cal/g · °C kJ/kg · K

0 273.15 1.0080 4.220 50 323.15 0.9992 4.183

10 283.15 1.0019 4.195 60 333.15 1.0001 4.187


20 293.15 0.9995 4.185 70 343.15 1.0013 4.192
25 298.15 0.9989 4.182 80 353.15 1.0029 4.199

30 303.15 0.9987 4.181 90 363.15 1.0050 4.208


40 313.15 0.9987 4.181 100 373.15 1.0076 4.219
Source: N. S. Osborne, H. F. Stimson, and D. C. Ginnings, Bur. Standards J. Res., 23, 197 (1939).

A.2-6. Thermal Conductivity of Liquid Water

Temperature Thermal Conductivity

°C °F K btu/h · ft · °F W/m · K

0 32 273.15 0.329 0.569


37.8 100 311.0 0.363 0.628

93.3 200 366.5 0.393 0.680

148.9 300 422.1 0.395 0.684

215.6 420 588.8 0.376 0.651

326.7 620 599.9 0.275 0.476


Source: D. L. Timrot and N. B. Vargaftik, J. Tech. Phys. (U.S.S.R.), 10, 1063 (1940); 6th International
Conference on the Properties of Steam, Paris, 1964.

A.2-7. Vapor Pressure of Saturated Ice–Water Vapor and Heat of Sublimation

Temperature Vapor Pressure Heat of Sublimation

K °F °C kPa Psia mm Hg btu/lbm kJ/kg

273.2 32 0 6.107 × 10−1 8.858 × 10−2 4.581 1218.6 2834.5

266.5 20 −6.7 3.478 × 10−1 5.045 × 10−2 2.609 1219.3 2836.1

261.0 10 −12.2 2.128 × 10−1 3.087 × 10−2 1.596 1219.7 2837.0

255.4 0 −17.8 1.275 × 10−1 1.849 × 10−2 0.9562 1220.1 2838.0

249.9 −10 −23.3 7.411 × 10−2 1.082 × 10−2 0.5596 1220.3 2838.4


244.3 −20 −28.9 3.820 × 10−2 6.181 × 10−3 0.3197 1220.5 2838.9

238.8 −30 −34.4 2.372 × 10−2 3.440 × 10−3 0.1779 1220.5 2838.9

233.2 −40 −40.0 1.283 × 10−2 1.861 × 10−3 0.09624 1220.5 2838.9


Source: ASHRAE, Handbook of Fundamentals. New York: ASHRAE, 1972.

A.2-8. Heat Capacity of Ice

Temperature cp Temperature cp

°F K btu/lbm  · °F kJ/kg · K °F K btu/lbm  · °F kJ/kg · K

32 273.15 0.500 2.093 −10 249.85 0.461 1.930

20 266.45 0.490 2.052 −20 244.25 0.452 1.892


10 260.95 0.481 2.014 −30 238.75 0.442 1.850

0 255.35 0.472 1.976 −40 233.15 0.433 1.813


Source: Adapted from ASHRAE, Handbook of Fundamentals. New York: ASHRAE, 1972.

A.2-9. Properties of Saturated Steam and Water (Steam Table), SI Units

Vapor Specific Volume (m 3 /kg) Enthalpy (kJ/kg) Entropy (kJ/kg · K)


Temperature Pressure
(°C) (kPa) Liquid Sat'd Vapor Liquid Sat'd Vapor Liquid Sat'd Vapor

0.01 0.6113 0.0010002 206.136 0.00 2501.4 0.0000 9.1562


3 0.7577 0.0010001 168.132 12.57 2506.9 0.0457 9.0773

6 0.9349 0.0010001 137.734 25.20 2512.4 0.0912 9.0003

9 1.1477 0.0010003 113.386 37.80 2517.9 0.1362 8.9253

12 1.4022 0.0010005 93.784 50.41 2523.4 0.1806 8.8524

15 1.7051 0.0010009 77.926 62.99 2528.9 0.2245 8.7814


18 2.0640 0.0010014 65.038 75.58 2534.4 0.2679 8.7123
21 2.487 0.0010020 54.514 88.14 2539.9 0.3109 8.6450

24 2.985 0.0010027 45.883 100.70 2545.4 0.3534 8.5794

25 3.169 0.0010029 43.360 104.89 2547.2 0.3674 8.5580


27 3.567 0.0010035 38.774 113.25 2550.8 0.3954 8.5156
30 4.246 0.0010043 32.894 125.79 2556.3 0.4369 8.4533
33 5.034 0.0010053 28.011 138.33 2561.7 0.4781 8.3927

36 5.947 0.0010063 23.940 150.86 2567.1 0.5188 8.3336


40 7.384 0.0010078 19.523 167.57 2574.3 0.5725 8.2570
45 9.593 0.0010099 15.258 188.45 2583.2 0.6387 8.1648

50 12.349 0.0010121 12.032 209.33 2592.1 0.7038 8.0763

55 15.758 0.0010146 9.568 230.23 2600.9 0.7679 7.9913


60 19.940 0.0010172 7.671 251.13 2609.6 0.8312 7.9096

65 25.03 0.0010199 6.197 272.06 2618.3 0.8935 7.8310


70 31.19 0.0010228 5.042 292.98 2626.8 0.9549 7.7553
75 38.58 0.0010259 4.131 313.93 2635.3 1.0155 7.6824

80 47.39 0.0010291 3.407 334.91 2643.7 1.0753 7.6122


85 57.83 0.0010325 2.828 355.90 2651.9 1.1343 7.5445

90 70.14 0.0010360 2.361 376.92 2660.1 1.1925 7.4791


95 84.55 0.0010397 1.9819 397.96 2668.1 1.2500 7.4159

100 101.35 0.0010435 1.6729 419.04 2676.1 1.3069 7.3549


105 120.82 0.0010475 1.4194 440.15 2683.8 1.3630 7.2958
110 143.27 0.0010516 1.2102 461.30 2691.5 1.4185 7.2387

115 169.06 0.0010559 1.0366 482.48 2699.0 1.4734 7.1833

120 198.53 0.0010603 0.8919 503.71 2706.3 1.5276 7.1296


125 232.1 0.0010649 0.7706 524.99 2713.5 1.5813 7.0775

130 270.1 0.0010697 0.6685 546.31 2720.5 1.6344 7.0269


135 313.0 0.0010746 0.5822 567.69 2727.3 1.6870 6.9777
140 316.3 0.0010797 0.5089 589.13 2733.9 1.7391 6.9299

145 415.4 0.0010850 0.4463 610.63 2740.3 1.7907 6.8833


150 475.8 0.0010905 0.3928 632.20 2746.5 1.8418 6.8379
155 543.1 0.0010961 0.3468 653.84 2752.4 1.8925 6.7935

160 617.8 0.0011020 0.3071 675.55 2758.1 1.9427 6.7502

165 700.5 0.0011080 0.2727 697.34 2763.5 1.9925 6.7078


170 791.7 0.0011143 0.2428 719.21 2768.7 2.0419 6.6663

175 892.0 0.0011207 0.2168 741.17 2773.6 2.0909 6.6256


180 1002.1 0.0011274 0.19405 763.22 2778.2 2.1396 6.5857

190 1254.4 0.0011414 0.15654 807.62 2786.4 2.2359 6.5079

200 1553.8 0.0011565 0.12736 852.45 2793.2 2.3309 6.4323


225 2548 0.0011992 0.07849 966.78 2803.3 2.5639 6.2503

250 3973 0.0012512 0.05013 1085.36 2801.5 2.7927 6.0730


275 5942 0.0013168 0.03279 1210.07 2785.0 3.0208 5.8938

300 8581 0.0010436 0.02167 1344.0 2749.0 3.2534 5.7045


Source: Abridged from J. H. Keenan, F. G. Keyes, P. G. Hill, and J. G. Moore, Steam Tables—Metric Units.
New York: John Wiley & Sons, Inc., 1969. Reprinted by permission of John Wiley & Sons, Inc.

A.2-9. Properties of Saturated Steam and Water (Steam Table), English Units

Specific Volume (ft 3 /lbm ) Enthalpy (btu/lbm ) Entropy (btu/lbm  · °F)


Vapor
Temperature Pressure Sat'd
(°F) (psia) Liquid Sat'd Vapor Liquid Sat'd Vapor Liquid Vapor

32.02 0.08866 0.016022 3302 0.00 1075.4 0.000 2.1869


35 0.09992 0.016021 2948 3.00 1076.7 0.00607 2.1764

40 0.12166 0.016020 2445 8.02 1078.9 0.01617 2.1592

45 0.14748 0.016021 2037 13.04 1081.1 0.02618 2.1423


50 0.17803 0.016024 1704.2 18.06 1083.3 0.03607 2.1259
55 0.2140 0.016029 1431.4 23.07 1085.5 0.04586 2.1099

60 0.2563 0.016035 1206.9 28.08 1087.7 0.05555 2.0943


65 0.3057 0.016042 1021.5 33.09 1089.9 0.06514 2.0791

70 0.3622 0.016051 867.7 38.09 1092.0 0.07463 2.0642


75 0.4300 0.016061 739.7 43.09 1094.2 0.08402 2.0497

80 0.5073 0.016073 632.8 48.09 1096.4 0.09332 2.0356


85 0.5964 0.016085 543.1 53.08 1098.6 0.10252 2.0218
90 0.6988 0.016099 467.7 58.07 1100.7 0.11165 2.0083

95 0.8162 0.016114 404.0 63.06 1102.9 0.12068 1.9951


100 0.9503 0.016130 350.0 68.05 1105.0 0.12963 1.9822
110 1.2763 0.016166 265.1 78.02 1109.3 0.14730 1.9574

120 1.6945 0.016205 203.0 88.00 1113.5 0.16465 1.9336


130 2.225 0.016247 157.17 97.98 1117.8 0.18172 1.9109

140 2.892 0.016293 122.88 107.96 1121.9 0.19851 1.8892

150 3.722 0.016343 96.99 117.96 1126.1 0.21503 1.8684

160 4.745 0.016395 77.23 127.96 1130.1 0.23130 1.8484


170 5.996 0.016450 62.02 137.97 1134.2 0.24732 1.8293

180 7.515 0.016509 50.20 147.99 1138.2 0.26311 1.8109

190 9.343 0.016570 40.95 158.03 1142.1 0.27866 1.7932

200 11.529 0.016634 33.63 168.07 1145.9 0.29400 1.7762

210 14.125 0.016702 27.82 178.14 1149.7 0.30913 1.7599


212 14.698 0.016716 26.80 180.16 1150.5 0.31213 1.7567

220 17.188 0.016772 23.15 188.22 1153.5 0.32406 1.7441

230 20.78 0.016845 19.386 198.32 1157.1 0.33880 1.7289

240 24.97 0.016922 16.327 208.44 1160.7 0.35335 1.7143


250 29.82 0.017001 13.826 218.59 1164.2 0.36772 1.7001
260 35.42 0.017084 11.768 228.76 1167.6 0.38193 1.6864

270 41.85 0.017170 10.066 238.95 1170.9 0.39597 1.6731


280 49.18 0.017259 8.650 249.18 1174.1 0.40986 1.6602
290 57.33 0.017352 7.467 259.44 1177.2 0.42360 1.6477
300 66.98 0.017448 6.472 269.73 1180.2 0.43720 1.6356

310 77.64 0.017548 5.632 280.06 1183.0 0.45067 1.6238


320 89.60 0.017652 4.919 290.43 1185.8 0.46400 1.6123

330 103.00 0.017760 4.312 300.84 1188.4 0.47722 1.6010

340 117.93 0.017872 3.792 311.30 1190.8 0.49031 1.5901


350 134.53 0.017988 3.346 321.80 1193.1 0.50329 1.5793
360 152.92 0.018108 2.961 332.35 1195.2 0.51617 1.5688

370 173.23 0.018233 2.628 342.96 1197.2 0.52894 1.5585


380 195.60 0.018363 2.339 353.62 1199.0 0.54163 1.5483

390 220 2 0 018498 2 087 364 34 1200 6 0 55422 1 5383


390 220.2 0.018 98 2.08 36 .3 1200.6 0.55 22 1.5383

400 247.1 0.018638 1.8661 375.12 1202.0 0.56672 1.5284

410 276.5 0.018784 1.6726 385.97 1203.1 0.57916 1.5187


450 422.1 0.019433 1.1011 430.2 1205.6 0.6282 1.4806
Source: Abridged from J. H. Keenan, F. G. Keyes, P. G. Hill, and J. G. Moore, Steam Tables—English Units.
New York: John Wiley & Sons, Inc., 1969. Reprinted by permission of John Wiley & Sons, Inc.

A.2-10. Properties of Superheated Steam (Steam Table), SI Units  (ν, specific volume, m 3 /kg; H,


enthalpy, kJ/kg; s, entr opy, kJ/kg · K)

Absolute  
Pressure, Temperature (°C)
kPa (Sat.   100 150 200 250 300 360 420 500
Temp.,°C)

  ν 17.196 19.512 21.825 24.136 26.445 29.216 31.986 35.679


10 H 2687.5 2783.0 2879.5 2977.3 3076.5 3197.6 3320.9 3489.1
(45.81) s 8.4479 8.6882 8.9038 9.1002 9.2813 9.4821 9.6682 9.8978

  ν 3.418 3.889 4.356 4.820 5.284 5.839 6.394 7.134

50 H 2682.5 2780.1 2877.7 2976.0 3075.5 3196.8 3320.4 3488.7

(81.33) s 7.6947 7.9401 8.1580 8.3556 8.5373 8.7385 8.9249 9.1546


  ν 2.270 2.587 2.900 3.211 3.520 3.891 4.262 4.755

75 H 2679.4 2778.2 2876.5 2975.2 3074.9 3196.4 3320.0 3488.4


(91.78) s 7.5009 7.7496 7.9690 8.1673 8.3493 8.5508 8.7374 8.9672

  ν 1.6958 1.9364 2.172 2.406 2.639 2.917 3.195 3.565

100 H 2672.2 2776.4 2875.3 2974.3 3074.3 3195.9 3319.6 3488.1


(99.63) s 7.3614 7.6134 7.8343 8.0333 8.2158 8.4175 8.6042 8.8342

  ν   1.2853 1.4443 1.6012 1.7570 1.9432 2.129 2.376


150 H   2772.6 2872.9 2972.7 3073.1 3195.0 3318.9 3487.6
(111.37) s   7.4193 7.6433 7.8438 8.0720 8.2293 8.4163 8.6466

  ν   0.4708 0.5342 0.5951 0.6548 0.7257 0.7960 0.8893

400 H   2752.8 2860.5 2964.2 3066.8 3190.3 3315.3 3484.9


(143.63) s   6.9299 7.1706 7.3789 7.5662 7.7712 7.9598 8.1913
  ν     0.2999 0.3363 0.3714 0.4126 0.4533 0.5070

700 H     2844.8 2953.6 3059.1 3184.7 3310.9 3481.7


(164.97) s     6.8865 7.1053 7.2979 7.5063 7.6968 7.9299
  ν     0.2060 0.2327 0.2579 0.2873 0.3162 0.3541

1000 H     2827.9 2942.6 3051.2 3178.9 3306.5 3478.5


(179.91) s     6.6940 6.9247 7.1229 7.3349 7.5275 7.7622

  ν     0.13248 0.15195 0.16966 0.18988 0.2095 0.2352


1500 H     2796.8 2923.3 3037.6 3.1692 3299.1 3473.1

(198.32) s     6.4546 6.7090 6.9179 7.1363 7.3323 7.5698


  ν       0.11144 0.12547 0.14113 0.15616 0.17568
2000 H       2902.5 3023.5 3159.3 3291.6 3467.6
(212.42) s       6.5453 6.7664 6.9917 7.1915 7.4317
  ν       0.08700 0.09890 0.11186 0.12414 0.13998
2500 H       2880.1 3008.8 3149.1 3284.0 3462.1

(223.99) s       6.4085 6.6438 6.8767 7.0803 7.3234


  νx       0.07058 0.08114 0.09233 0.10279 0.11619
3000 H       2855.8 2993.5 3138.7 3276.3 3456.5

(233.90) s       6.2872 6.5390 6.7801 6.9878 7.2338


Source: Abridged from J. H. Keenan, F. G. Keyes, P. G. Hill, and J. G. Moore, Steam Tables—Metric
Units. New York: John Wiley & Sons, Inc., 1969. Reprinted by permission of John Wiley & Sons, Inc.

A.2-10. Properties of Superheated Steam (Steam Table), English Units (ν, specific volume, ft 3 /lbm ;

H, enthalpy, btu/lbm ; s, entropy, btu/lbm  · °F)

Absolute  
Pressure, Temperature (°F)
kPa (Sat.
Temp.,   200 300 400 500 600 700 800 900 1000
°F)

  ν 392.5 452.3 511.9 571.5 631.1 690.7 750.3 809.9 869.5

1.0 H 1150.1 1195.7 1241.8 1288.5 1336.1 1384.5 1433.7 1483.8 1534.8
(101.70) s 2.0508 2.1150 2.1720 2.2235 2.2706 2.3142 2.3550 2.3932 2.4294

  ν 78.15 90.24 102.24 114.20 126.15 138.08 150.01 161.94 173.86

5.0 H 1148.6 1194.8 1241.2 1288.2 1335.8 1384.3 1433.5 1483.7 1534.7

(162.21) s 1.8715 1.9367 1.9941 2.0458 2.0930 2.1367 2.1775 2.2158 2.2520
  ν 38.85 44.99 51.03 57.04 63.03 69.01 74.98 80.95 86.91

10.0 H 1146.6 1193.7 1240.5 1287.7 1335.5 1384.0 1433.3 1483.5 1534.6
(193.19) s 1.7927 1.8592 1.9171 1.9690 2.0164 2.0601 2.1009 2.1393 2.1755

  ν   30.52 34.67 38.77 42.86 46.93 51.00 55.07 59.13


14.696 H   1192.6 1239.9 1287.3 1335.2 1383.8 1433.1 1483.4 1534.5
(211.99) s   1.8157 1.8741 1.9263 1.9737 2.0175 2.0584 2.0967 2.1330
  ν   22.36 25.43 28.46 31.47 34.77 37.46 40.45 43.44

20.0 H   1191.5 1239.2 1286.8 1334.8 1383.5 1432.9 1483.2 1534.3


(227.96) s   1.7805 1.8395 1.8919 1.9395 1.9834 2.0243 2.0627 2.0989
  ν   7.260 8.353 9.399 10.425 11.440 12.448 13.452 14.454

60.0 H   1181.9 1233.5 1283.0 1332.1 1381.4 1431.2 1481.8 1533.2


(292.73) s   1.6496 1.7134 1.7678 1.8165 1.8609 1.9022 1.9408 1.9773

  ν     4.934 5.587 6.216 6.834 7.445 8.053 8.657

100.0 H     1227.5 1279.1 1329.3 1379.2 1429.6 1480.5 1532.1


(327.86) s     1.6517 1.7085 1.7582 1.8033 1.8449 1.8838 1.9204
  ν     3.221 3.679 4.111 4.531 4.944 5.353 5.759
150.0 H     1219.5 1274.1 1325.7 1376.6 1427.5 1478.8 1530.7
(358.48) s     1.5997 1.6598 1.7110 1.7568 1.7989 1.8381 1.8750

  ν     2.361 2.724 3.058 3.379 3.693 4.003 4.310

200.0 H     1210.8 1268.8 1322.1 1373.8 1425.3 1477.1 1529.3


(381.86) s     1.5600 1.6239 1.6767 1.7234 1.7660 1.8055 1.8425
  ν       2.150 2.426 2.688 2.943 3.193 3.440

250.0 H       1263.3 1318.3 1371.1 1423.2 1475.3 1527.9


(401.04) s       1.5948 1.6494 1.6970 1.7401 1.7799 1.8172
  ν       1.766 2.004 2.227 2.442 2.653 2.860

300.0 H       1257.5 1314.5 1368.3 1421.0 1473.6 1526.5


(417.43) s       1.5701 1.6266 1.6751 1.7187 1.7589 1.7964

  ν       1.2843 1.4760 1.6503 1.8163 1.9776 2.136

400 H       1245.2 1306.6 1362.5 1416.6 1470.1 1523.6


(444.70) s       1.5282 1.5892 1.6397 1.6884 1.7252 1.7632
Source: Abridged from J. H. Keenan, F. G. Keyes, P. G. Hill, and J. G. Moore, Steam Tables—Metric
Units. New York: John Wiley & Sons, Inc., 1969. Reprinted by permission of John Wiley & Sons, Inc.

A.2-11. Heat-Transfer Properties of Liquid Water, SI Units

(gβρ2 /μ2 ) ×


μ ×103
ρ c p  (kJ/kg · (Pa · s, or k (W/m · 10−8  (1/K ·
T (°C) T (K) (kg/m 3 ) K) kg/m · s) K) NPr β × 104  (1/K) m 3)

0 273.2 999.6 4.229 1.786 0.5694 13.3 −0.630  


15.6 288.8 998.0 4.187 1.131 0.5884 8.07 1.44 10.93

26.7 299.9 996.4 4.183 0.860 0.6109 5.89 2.34 30.70

37.8 311.0 994.7 4.183 0.682 0.6283 4.51 3.24 68.0

65.6 338.8 981.9 4.187 0.432 0.6629 2.72 5.04 256.2

93.3 366.5 962.7 4.229 0.3066 0.6802 1.91 6.66 642


121.1 394.3 943.5 4.271 0.2381 0.6836 1.49 8.46 1300
148.9 422.1 917.9 4.312 0.1935 0.6836 1.22 10.08 2231

204.4 477.6 858.6 4.522 0.1384 0.6611 0.950 14.04 5308


260.0 533.2 784.9 4.982 0.1042 0.6040 0.859 19.8 11 030

315.6 588.8 679.2 6.322 0.0862 0.5071 1.07 31.5 19 260

A.2-11. Heat-Transfer Properties of Liquid Water, English Units

(gβρ2 /μ2 ) ×


T β × 104 10−6  (1/°R ·
(°F) NPr (1/°R) ft 3)

32 62.4 1.01 1.20 0.329 13.3 −0.350  

60 62.3 1.00 0.760 0.340 8.07 0.800 17.2


80 62.2 0.999 0.578 0.353 5.89 1.30 48.3
100 62.1 0.999 0.458 0.363 4.51 1.80 107

150 61.3 1.00 0.290 0.383 2.72 2.80 403

200 60.1 1.01 0.206 0.393 1.91 3.70 1010


250 58.9 1.02 0.160 0.395 1.49 4.70 2045
300 57.3 1.03 0.130 0.395 1.22 5.60 3510
400 53.6 1.08 0.0930 0.382 0.950 7.80 8350

500 49.0 1.19 0.0700 0.349 0.859 11.0 17 350


600 42.4 1.51 0.0579 0.293 1.07 17.5 30 300

A.2-12. Heat-Transfer Properties of Water Vapor (Steam) at 101.32 kPa (1 Atm  Abs), SI Units

μ × 105
ρ c p  (kJ/kg (Pa · s, or k (W/m · β × 103 (gβρ2 /μ2 )
T (°C) T (K) (kg/m 3 ) · K) kg/m · s) K) NPr (1/K) (1/K · m 3 )

100.0 373.2 0.596 1.888 1.295 0.02510 0.96 2.68 0.557 × 108

148.9 422.1 0.525 1.909 1.488 0.02960 0.95 2.38 0.292 × 108

204.4 477.6 0.461 1.934 1.682 0.03462 0.94 2.09 0.154 × 108

260.0 533.2 0.413 1.968 1.883 0.03946 0.94 1.87 0.0883 × 108

315.6 588.8 0.373 1.997 2.113 0.04448 0.94 1.70 52.1 × 105

371.1 644.3 0.341 2.030 2.314 0.04985 0.93 1.55 33.1 × 105

426.7 699.9 0.314 2.068 2.529 0.05556 0.92 1.43 21.6 × 105

A.2-12. Heat-Transfer Properties of Water Vapor (Steam) at 101.32 kPa (1 Atm  Abs), English Units

T β × 103 (gβρ2 /μ2 )


(°F) NPr (1/°R) (1/°R · ft 3)

212 0.0372 0.451 0.870 0.0145 0.96 1.49 0.877 × 106

300 0.0328 0.456 1.000 0.0171 0.95 1.32 0.459 × 106

400 0.0288 0.462 1.130 0.0200 0.94 1.16 0.243 × 106

500 0.0258 0.470 1.265 0.0228 0.94 1.04 0.139 × 106

600 0.0233 0.477 1.420 0.0257 0.94 0.943 82 × 103

700 0.0213 0.485 1.555 0.0288 0.93 0.862 52.1 × 103

800 0.0196 0.494 1.700 0.0321 0.92 0.794 34.0 × 103

Source: D. L. Timrot and N. B. Vargaftik, J. Tech. Phys. (U.S.S.R.), 10, 1063 (1940); R. H. Perry and C.
H. Chilton. Chemical Engineers' Handbook, 5th ed. New York: McGraw-Hill Book Company, 1973; J. H.
Keenan, F. G. Keyes, P. G. Hill, and J. G. Moore, Steam Tables. New York: John Wiley & Sons, Inc.,
1969; National Research Council, International Critical Tables. New York: McGraw-Hill Book
Company  1929; L  S  Marks  Mechanical Engineers' Handbook  5th ed  New York: McGraw-Hill Book
Company, 1929; L. S. Marks, Mechanical Engineers  Handbook, 5th ed. New York: McGraw Hill Book
Company, 1951.
                             
                                                 
                                             
                                               
     

Appendix A.3. Physical Properties of Inorganic and
Organic Compounds

A.3-1. Standard Heats  of Formation at 298.15 K (25°C) and 101.325 kPa (1 Atm  Abs), (c) =


crystalline, (g) = gas, (l) = liquid

   

Compound (kJ/kg mol)10−3 kcal/g mol Compound (kJ/kg mol)10−3 kcal/g mol

NH3 (g) −46.19 −11.04 CaCO3 (c) −1206.87 −288.45

NO(g) +90.374 +21.600 CaO(c) −635.5 −151.9

H2 O(l) −285.840 −68.3174 CO(g) −110.523 −26.4157

H2 O(g) −241.826 −57.7979 CO2 (g) −393.513 −94.0518

HCN(g) +130.1 +31.1 CH4 (g) −74.848 −17.889

HCl(g) −92.312 −22.063 C2 H6 (g) −84.667 −20.236

H2 SO4 (l) −811.32 −193.91 C3 H8 (g) −103.847 −24.820

H3 PO4 (c) −1281.1 −306.2 CH3 OH(l) −238.66 −57.04

NaCl(c) −411.003 −98.232 CH3 CH3 OH(l) −277.61 −66.35

NH4 Cl(c) −315.39 −75.38      


Source: J. H. Perry and C. H. Chilton, Chemical Engineers' Handbook, 5th ed. New York: McGraw-Hill
Book Company, 1973; and O. A. Hougen, K. M. Watson, and R. A. Ragatz, Chemical Process
Principles, Part I, 2nd ed. New York: John Wiley & Sons, Inc., 1954.

A.3-2. Standard Heats  of Combustion at 298.15 K (25°C) and 101.325 kPa (1 Atm  Abs) (g) = gas, (l) = liquid, (s)


= solid

   

(kJ/kg
Compound Combustion Reaction kcal/g mol mol)10−3

C(s) −26.4157 −110.523

CO(g) −67.6361 −282.989

C(s) C(s) + O2 (g) → CO2 (g) −94.0518 −393.513

H2 (g) −68.3174 −285.840

H2 (g) −57.7979 −241.826


CH4 (g) CH4 (g) + 2O2 (g) → CO2 (g) + 2H2 O(l) −212.798 −890.346

C2 H6 (g) −372.820 −1559.879

C3 H8 (g) C3 H8 (g) + 5O2 (g) → 3CO2 (g) + 4H2 O(l) −530.605 −2220.051

d-Glucose C6 H12 O6 (s) + 6O2 (g) → 6CO2 (g) + 6H2 O(l) −673 −2816


(dextrose)
C6 H12 O6 (s)

Lactose C12 H22 O11 (s) + 12O2 (g) → 12CO2 (g) + 11H2 O(l) −1350.1 −5648.8
(anhydrous)
C12 H22 O11 (s)

Sucrose C12 H22 O11 (s) + 12O2 (g) → 12CO2 (g) + 11H2 O(l) −1348.9 −5643.8
C12 H22 O11 (s)
Source: R. H. Perry and C. H. Chilton, Chemical Engineers' Handbook, 5th ed. New York: McGraw-Hill Book
Company, 1973; and O. A. Hougen, K. M. Watson, and R. A. Ragatz, Chemical Process Principles, Part I, 2nd ed.
New York: John Wiley & Sons, Inc., 1954.

Figure A.3-1. Mean molar heat capacities from 77°F (25°C) to t°F at constant pressure of 101.325 kPa (1 atm
abs). (From O. A. Hougen, K. M. Watson, and R. A. Ragatz, Chemical Process Principles, Part I, 2nd ed. New
York: John Wiley & Sons, Inc., 1954. With permission.)

[View full size image]

A.3-3. Physical Properties of Air at 101.325 kPa (1 Atm Abs), SI Units

μ × 105  (Pa ·
cp s, or kg/m · k (W/m · β × 103 gβρ2 /μ2  (1/K ·
T (°C) T (K) 3
ρ (kg/m ) (kJ/kg·K) s) K) NPr (1/K) m 3)

−17.8 255.4 1.379 1.0048 1.62 0.02250 0.720 3.92 2.79 × 108

0 273.2 1.293 1.0048 1.72 0.02423 0.715 3.65 2.04 × 108


10.0 283.2 1.246 1.0048 1.78 0.02492 0.713 3.53 1.72 × 108

37.8 311.0 1.137 1.0048 1.90 0.02700 0.705 3.22 1.12 × 108

65.6 338.8 1.043 1.0090 2.03 0.02925 0.702 2.95 0.775 × 108

93.3 366.5 0.964 1.0090 2.15 0.03115 0.694 2.74 0.534 × 108

121.1 394.3 0.895 1.0132 2.27 0.03323 0.692 2.54 0.386 × 108

148.9 422.1 0.838 1.0174 2.37 0.03531 0.689 2.38 0.289 × 108

176.7 449.9 0.785 1.0216 2.50 0.03721 0.687 2.21 0.214 × 108

204.4 477.6 0.740 1.0258 2.60 0.03894 0.686 2.09 0.168 × 108

232.2 505.4 0.700 1.0300 2.71 0.04084 0.684 1.98 0.130 × 108

260.0 533.2 0.662 1.0341 2.80 0.04258 0.680 1.87 0.104 × 108

A.3-3. Physical Properties of Air at 101.325 kPa (1 Atm Abs), English Units

β × 103 gβρ2 /μ2  (1/°


T (°F) μ (centipoise) NPr (1/°R) R · ft 3 )

0 0.0861 0.240 0.0162 0.0130 0.720 2.18 4.39 × 106

32 0.0807 0.240 0.0172 0.0140 0.715 2.03 3.21 × 106

50 0.0778 0.240 0.0178 0.0144 0.713 1.96 2.70 × 106

100 0.0710 0.240 0.0190 0.0156 0.705 1.79 1.76 × 106

150 0.0651 0.241 0.0203 0.0169 0.702 1.64 1.22 × 106

200 0.0602 0.241 0.0215 0.0180 0.694 1.52 0.840 × 106

250 0.0559 0.242 0.0227 0.0192 0.692 1.41 0.607 × 106

300 0.0523 0.243 0.0237 0.0204 0.689 1.32 0.454 × 106

350 0.0490 0.244 0.0250 0.0215 0.687 1.23 0.336 × 106

400 0.0462 0.245 0.0260 0.0225 0.686 1.16 0.264 × 106

450 0.0437 0.246 0.0271 0.0236 0.674 1.10 0.204 × 106

500 0.0413 0.247 0.0280 0.0246 0.680 1.04 0.163 × 106


Source: National Bureau of Standards, Circular 461C, 1947; 564, 1955; NBS–NACA, Tables of Thermal
Properties of Gases, 1949; F. G. Keyes, Trans. A.S.M.E., 73, 590, 597 (1951); 74, 1303 (1952); D. D. Wagman,
Selected Values of Chemical Thermodynamic Properties. Washington, D.C.: National Bureau of Standards, 1953.

A.3-4. Viscosity of Gases at 101.325 kPa (1 Atm Abs) [Viscosity in (Pas) 103 , (kg/ms) 103 , or cp]

Temperature          
K °F °C H2 O2 N2 CO CO2

255.4 0 −17.8 0.00800 0.0181 0.0158 0.0156 0.0128


273.2 32 0 0.00840 0.0192 0.0166 0.0165 0.0137
283.2 50 10.0 0.00862 0.0197 0.0171 0.0169 0.0141

311.0 100 37.8 0.00915 0.0213 0.0183 0.0183 0.0154


338.8 150 65.6 0.00960 0.0228 0.0196 0.0195 0.0167
366.5 200 93.3 0.0101 0.0241 0.0208 0.0208 0.0179

394.3 250 121.1 0.0106 0.0256 0.0220 0.0220 0.0191


422.1 300 148.9 0.0111 0.0267 0.0230 0.0231 0.0203
449.9 350 176.7 0.0115 0.0282 0.0240 0.0242 0.0215

477.6 400 204.4 0.0119 0.0293 0.0250 0.0251 0.0225


505.4 450 232.2 0.0124 0.0307 0.0260 0.0264 0.0236

533.2 500 260.0 0.0128 0.0315 0.0273 0.0276 0.0247


Source: National Bureau of Standards, Circular 461C, 1947; 564, 1955; NBS–NACA, Tables of
Thermal Properties of Gases, 1949; F. G. Keyes, Trans. A.S.M.E., 73, 590, 597 (1951); 74, 1303
(1952); D. D. Wagman, Selected Values of Chemical Thermodynamic Properties. Washington, D.C.:
National Bureau of Standards, 1953.

A.3-5. Thermal Conductivity of Gases at 101.325 kPa (1 Atm Abs)

H2 O2 N2 CO CO2

Temperature          
btu/ h·ft· btu/ btu/ btu/ btu/
K °C °F W/m·K °F W/m·K h·ft·°F W/m·K h·ft·°F W/m·K h·ft·°F W/m·K h·ft·°F

255.4 −17.8 0 0.1592 0.0920 0.0228 0.0132 0.0228 0.0132 0.0222 0.0128 0.0132 0.0076
273.2 0 32 0.1667 0.0963 0.0246 0.0142 0.0239 0.0138 0.0233 0.0135 0.0145 0.0084

283.2 10.0 50 0.1720 0.0994 0.0253 0.0146 0.0248 0.0143 0.0239 0.0138 0.0152 0.0088
311.0 37.8 100 0.1852 0.107 0.0277 0.0160 0.0267 0.0154 0.0260 0.0150 0.0173 0.0100

338.8 65.6 150 0.1990 0.115 0.0299 0.0173 0.0287 0.0166 0.0279 0.0161 0.0190 0.0110

366.5 93.3 200 0.2111 0.122 0.0320 0.0185 0.0303 0.0175 0.0296 0.0171 0.0216 0.0125
394.3 121.1 250 0.2233 0.129 0.0343 0.0198 0.0329 0.0190 0.0318 0.0184 0.0239 0.0138

422.1 148.9 300 0.2353 0.136 0.0363 0.0210 0.0348 0.0201 0.0338 0.0195 0.0260 0.0150
449.9 176.7 350 0.2458 0.142 0.0382 0.0221 0.0365 0.0211 0.0355 0.0205 0.0286 0.0165

477.6 204.4 400 0.2579 0.149 0.0398 0.0230 0.0382 0.0221 0.0369 0.0213 0.0308 0.0178
505.4 232.2 450 0.2683 0.155 0.0422 0.0244 0.0400 0.0231 0.0384 0.0222 0.0334 0.0193
533.2 260.0 500 0.2786 0.161 0.0438 0.0253 0.0419 0.0242 0.0407 0.0235 0.0355 0.0205
Source: National Bureau of Standards, Circular 461C, 1947; 564, 1955; NBS–NACA, Table of Thermal
Properties of Gases, 1949; F. G. Keyes, Trans. A.S.M.E., 73, 590, 597 (1951); 74, 1303 (1952); D. D.
Wagman, Selected Values of Chemical Thermodynamic Properties. Washington, D.C.: National Bureau of
Standards, 1953.

A.3-6. Heat Capacity of Gases at Constant Pressure at 101.325 kPa (1 Atm Abs)

Temperature
H2 O2 N2 CO CO2

K °C °F kJ/kgK btu/lbm °F kJ/kgK btu/lbm °F kJ/kgK btu/lbm °F kJ/kgK btu/lbm °F kJ/kgK btu/lbm °F

255.4 −17.8 0 14.07 3.36 0.909 0.217 1.034 0.247 1.034 0.247 0.800 0.191

273.2 0 32 14.19 3.39 0.913 0.218 1.038 0.248 1.038 0.248 0.816 0.195

283.2 10.0 50 14.19 3.39 0.917 0.219 1.038 0.248 1.038 0.248 0.825 0.197
311.0 37.8 100 14.32 3.42 0.921 0.220 1.038 0.248 1.043 0.249 0.854 0.204
338.8 65.6 150 14.36 3.43 0.925 0.221 1.038 0.248 1.043 0.249 0.883 0.211

366.5 93.3 200 14.40 3.44 0.929 0.222 1.043 0.249 1.047 0.250 0.904 0.216

394.3 121.1 250 14.44 3.45 0.938 0.224 1.043 0.249 1.047 0.250 0.929 0.222
422.1 148.9 300 14.49 3.46 0.946 0.226 1.047 0.250 1.051 0.251 0.950 0.227
449.9 176.7 350 14.49 3.46 0.955 0.228 1.047 0.250 1.055 0.252 0.976 0.233

477.6 204.4 400 14.49 3.46 0.963 0.230 1.051 0.251 1.059 0.253 0.996 0.238
505.4 232.2 450 14.52 3.47 0.971 0.232 1.055 0.252 1.063 0.254 1.017 0.243

533.2 260.0 500 14.52 3.47 0.976 0.233 1.059 0.253 1.068 0.255 1.030 0.246
Source: National Bureau of Standards, Circular 461C, 1947; 564, 1955; NBS–NACA, Tables of Thermal Properties
of Gases, 1949; F. G. Keyes, Trans. A.S.M.E., 73, 590, 597 (1951); 74, 1303 (1952); D. D. Wagman, Selected
Values of Chemical Thermodynamic Properties. Washington, D.C.: National Bureau of Standards, 1953.

A.3-7. Prandtl Number of Gases at 101.325 kPa (1 Atm Abs)

Temperature          

°C °F K H2 O2 N2 CO CO2

−17.8 0 255.4 0.720 0.720 0.720 0.740 0.775


0 32 273.2 0.715 0.711 0.720 0.738 0.770

10.0 50 283.2 0.710 0.710 0.717 0.735 0.769

37.8 100 311.0 0.700 0.707 0.710 0.731 0.764


65.6 150 338.8 0.700 0.706 0.700 0.727 0.755
93.3 200 366.5 0.694 0.703 0.700 0.724 0.752

121.1 250 394.3 0.688 0.703 0.696 0.720 0.746


148.9 300 422.1 0.683 0.703 0.690 0.720 0.738
176.6 350 449.9 0.677 0.704 0.689 0.720 0.734
204.4 400 477.6 0.670 0.706 0.688 0.720 0.725

232.2 450 505.4 0.668 0.702 0.688 0.720 0.716


260.0 500 533.2 0.666 0.700 0.688 0.720 0.702
Source: National Bureau of Standards, Circular 461C, 1947; 564, 1955; NBS–NACA, Tables of
Thermal Properties of Gases, 1949; F. G. Keyes, Trans. A.S.M.E., 73, 590, 597 (1951); 74, 1303
(1952); D. D. Wagman, Selected Values of Chemical Thermodynamic Properties. Washington, D.C.:
National Bureau of Standards, 1953.

Figure A.3-2. Viscosities of gases at 101.325 kPa (1 atm abs). (From R. H. Perry and C. H. Chilton, Chemical
Engineers' Handbook, 5th ed. New York: McGraw-Hill Book Company, 1973. With permission.) See Table A.3-
8 for coordinates for use with Fig. A.3-2.
A.3-8. Viscosities of Gases (Coordinates for Use with Fig. A.3-2)

No. Gas X Y No. Gas X Y

1 Acetic acid 7.7 14.3 29 Freon-113 11.3 14.0

2 Acetone 8.9 13.0 30 Helium 10.9 20.5

3 Acetylene 9.8 14.9 31 Hexane 8.6 11.8


4 Air 11.0 20.0 32 Hydrogen 11.2 12.4

5 Ammonia 8.4 16.0 33 3H2  + 1N2 11.2 17.2

6 Argon 10.5 22.4 34 Hydrogen bromide 8.8 20.9


7 Benzene 8.5 13.2 35 Hydrogen chloride 8.8 18.7

8 Bromine 8.9 19.2 36 Hydrogen cyanide 9.8 14.9


9 Butene 9.2 13.7 37 Hydrogen iodide 9.0 21.3
10 Butylene 8.9 13.0 38 Hydrogen sulfide 8.6 18.0
11 Carbon dioxide 9.5 18.7 39 Iodine 9.0 18.4

12 Carbon disulfide 8.0 16.0 40 Mercury 5.3 22.9

13 Carbon monoxide 11.0 20.0 41 Methane 9.9 15.5


14 Chlorine 9.0 18.4 42 Methyl alcohol 8.5 15.6
15 Chloroform 8.9 15.7 43 Nitric oxide 10.9 20.5

16 Cyanogen 9.2 15.2 44 Nitrogen 10.6 20.0

17 Cyclohexane 9.2 12.0 45 Nitrosyl chloride 8.0 17.6


18 Ethane 9.1 14.5 46 Nitrous oxide 8.8 19.0
19 Ethyl acetate 8.5 13.2 47 Oxygen 11.0 21.3

20 Ethyl alcohol 9.2 14.2 48 Pentane 7.0 12.8


21 Ethyl chloride 8.5 15.6 49 Propane 9.7 12.9

22 Ethyl ether 8.9 13.0 50 Propyl alcohol 8.4 13.4


23 Ethylene 9.5 15.1 51 Propylene 9.0 13.8

24 Fluorine 7.3 23.8 52 Sulfur dioxide 9.6 17.0


25 Freon-11 10.6 15.1 53 Toluene 8.6 12.4

26 Freon-12 11.1 16.0 54 2,3,3- 9.5 10.5


Trimethylbutane
27 Freon-21 10.8 15.3 55 Water 8.0 16.0

28 Freon-22 10.1 17.0 56 Xenon 9.3 23.0

Figure A.3-3. Heat capacity of gases at constant pressure at 101.325 kPa (1 atm abs). (From R. H. Perry and
C. H. Chilton, Chemical Engineers' Handbook, 5th ed. New York: McGraw-Hill Book Company, 1973. With
permission.) See Table A.3-9 for use with Fig. A.3-3.

[View full size image]
A.3-9. Heat Capacity of Gases at Constant Pressure (for Use with Fig. A.3-3)

No. Gas Range (°C)

10 Acetylene 0–200
15 Acetylene 200–400

16 Acetylene 400–1400
27 Air 0–1400

12 Ammonia 0–600
14 Ammonia 600–1400

18 Carbon dioxide 0–400
24 Carbon dioxide 400–1400

26 Carbon monoxide 0–1400
32 Chlorine 0–200

34 Chlorine 200–1400

3 Ethane 0–200
9 Ethane 200–600
8 Ethane 600–1400
4 Ethylene 0–200

11 Ethylene 200–600

13 Ethylene 600–1400
17B Freon-11 (CCl3 F) 0–150

17C Freon-21 (CHCl2 F) 0–150

17A Freon-22 (CHClF2 ) 0–150

17D Freon-113 (CCl2 F—CClF2 ) 0–150

1 Hydrogen 0–600
2 Hydrogen 600–1400

35 Hydrogen bromide 0–1400

30 Hydrogen chloride 0–1400

20 Hydrogen fluoride 0–1400

36 Hydrogen iodide 0–1400

19 Hydrogen sulfide 0–700

21 Hydrogen sulfide 700–1400

5 Methane 0–300

6 Methane 300–700

7 Methane 700–1400
25 Nitric oxide 0–700

28 Nitric oxide 700–1400

26 Nitrogen 0–1400
23 Oxygen 0–500
29 Oxygen 500–1400

33 Sulfur 300–1400

22 Sulfur dioxide 0–400
31 Sulfur dioxide 400–1400

17 Water 0–1400

A.3-10. Thermal Conductivities of Gases and Vapors at 101.325 kPa (1 Atm Abs); k = W/m · K

Gas or Vapor K K Gas or Vapor K k

Acetone[1] 273 0.0099 Ethane[5]  [6] 239 0.0149

  319 0.0130   273 0.0183

  373 0.0171   373 0.0303


  457 0.0254 Ethyl alcohol[1] 293 0.0154

Ammonia[2] 273 0.0218   373 0.0215

  373 0.0332 Ethyl ether[1] 273 0.0133

  473 0.0484   319 0.0171


Butane[3] 273 0.0135   373 0.0227

  373 0.0234 Ethylene[6] 273 0.0175

Carbon monoxide[2] 173 0.0152   323 0.0227

  273 0.0232   373 0.0279


  373 0.0305 n-Hexane[3] 273 0.0125

Chlorine[4] 273 0.00744   293 0.0138

      Sulfur dioxide[7] 273 0.0087

        373 0.0119
Source:

[1]
 Moser, dissertation, Berlin, 1913;

[5]
 T. H. Chilton and R. P. Genereaux, personal communication, 1946;

[6]
 A. Eucken, Physik, Z., 12, 1101 (1911); 14. 324 (1913);

[2]
 F. G. Keyes, Tech. Rept. 37, Project Squid, Apr. 1, 1952;

[3]
 W. B. Mann and B. G. Dickens, Proc. Roy. Soc. (London). A134, 77 (1931);

[4]
 International Critical Tables. New York: McGraw-Hill Book Company, 1929;

[7]
 B. G. Dickens, Proc. Roy. Soc. (London), A143, 517 (1934).

A.3-11. Heat Capacities of Liquids (c p  kJ/kgK)

Liquid K cp Liquid K cp

Acetic acid 273 1.959 Hydrochloric acid (20 273 2.43


mol %)
  311 2.240   293 2.474
Acetone 273 2.119 Mercury 293 0.01390

  293 2.210 Methyl alcohol 293 2.512


Aniline 273 2.001   313 2.583

  323 2.181 Nitrobenzene 283 1.499


Benzene 293 1.700   303 1.419

  333 1.859   363 1.436

Butane 273 2.300 Sodium chloride (9.1 293 3.39


mol %)
i-Butyl alcohol 303 2.525   330 3.43

Ethyl alcohol 273 2.240 Sulfuric acid (100%) 293 1.403

  298 2.433 Toluene 273 1.616


Formic acid 273 1.825   323 1.763
  289 2.131 o-Xylene 303 1.721

Glycerol 288 2.324      


  305 2.412      
Source: N. A. Lange, Handbook of Chemistry, 10th ed. New York: McGraw-Hill Book Company, 1967;
National Research Council, International Critical Tables, Vol. V. New York: McGraw-Hill Book
Company, 1929; R. H. Perry and C. H. Chilton, Chemical Engineers' Handbook, 5th ed. New York:
McGraw-Hill Book Company, 1973.

Figure A.3-4. Viscosities of liquids. (From R. H. Perry and C. H. Chilton, Chemical Engineers' Handbook, 5th
ed. New York: McGraw-Hill Book Company, 1973. With permission.) See Table A.3-12 for use with Fig. A.3-4.
A.3-12. Viscosities of Liquids (Coordinates for Use with Fig. A.3-4)
Liquid X Y Liquid X Y

Acetaldehyde 15.2 4.8 Dibromomethane 12.7 15.8

Acetic acid, 100% 12.1 14.2 Dichloroethane 13.2 12.2


Acetic acid, 70% 9.5 17.0 Dichloromethane 14.6 8.9
Acetic anhydride 12.7 12.8 Diethyl ketone 13.5 9.2

Acetone, 100% 14.5 7.2 Diethyl oxalate 11.0 16.4


Acetone, 35% 7.9 15.0 Diethylene glycol 5.0 24.7
Acetonitrile 14.4 7.4 Diphenyl 12.0 18.3
Acrylic acid 12.3 13.9 Dipropyl ether 13.2 8.6

Allyl alcohol 10.2 14.3 Dipropyl oxalate 10.3 17.7


Allyl bromide 14.4 9.6 Ethyl acetate 13.7 9.1

Allyl iodide 14.0 11.7 Ethyl acrylate 12.7 10.4

Ammonia, 100% 12.6 2.0 Ethyl alcohol, 100% 10.5 13.8


Ammonia, 26% 10.1 13.9 Ethyl alcohol, 95% 9.8 14.3

Amyl acetate 11.8 12.5 Ethyl alcohol, 40% 6.5 16.6

Amyl alcohol 7.5 18.4 Ethyl benzene 13.2 11.5

Aniline 8.1 18.7 Ethyl bromide 14.5 8.1

Anisole 12.3 13.5 2-Ethyl butyl acrylate 11.2 14.0

Arsenic trichloride 13.9 14.5 Ethyl chloride 14.8 6.0

Benzene 12.5 10.9 Ethyl ether 14.5 5.3

Brine, CaCl2 , 25% 6.6 15.9 Ethyl formate 14.2 8.4

Brine, NaCl, 25% 10.2 16.6 2-Ethyl hexyl acrylate 9.0 15.0

Bromine 14.2 13.2 Ethyl iodide 14.7 10.3

Bromotoluene 20.0 15.9 Ethyl propionate 13.2 9.9

Butyl acetate 12.3 11.0 Ethyl propyl ether 14.0 7.0


Butyl acrylate 11.5 12.6 Ethyl sulfide 13.8 8.9

Butyl alcohol 8.6 17.2 Ethylene bromide 11.9 15.7


Butyric acid 12.1 15.3 Ethylene chloride 12.7 12.2
Carbon dioxide 11.6 0.3 Ethylene glycol 6.0 23.6
Carbon disulfide 16.1 7.5 Ethylidene chloride 14.1 8.7

Carbon 12.7 13.1 Fluorobenzene 13.7 10.4


tetrachloride
Chlorobenzene 12.3 12.4 Formic acid 10.7 15.8

Chloroform 14.4 10.2 Freon-11 14.4 9.0


Chlorosulfonic 11.2 18.1 Freon-12 16.8 15.6
acid
Chlorotoluene, 13.0 13.3 Freon-21 15.7 7.5
ortho

Chlorotoluene, 13.3 12.5 Freon-22 17.2 4.7


meta

Chlorotoluene, 13.3 12.5 Freon-113 12.5 11.4


para
Cresol, meta 2.5 20.8 Glycerol, 100% 2.0 30.0

Cyclohexanol 2.9 24.3 Glycerol, 50% 6.9 19.6


Cyclohexane 9.8 12.9 Heptane 14.1 8.4

Hexane 14.7 7.0 Pentane 14.9 5.2

Hydrochloric acid, 13.0 16.6 Phenol 6.9 20.8


31.5%
Iodobenzene 12.8 15.9 Phosphorus tribromide 13.8 16.7

Isobutyl alcohol 7.1 18.0 Phosphorus trichloride 16.2 10.9


Isobutyric acid 12.2 14.4 Propionic acid 12.8 13.8

Isopropyl alcohol 8.2 16.0 Propyl acetate 13.1 10.3

Isopropyl bromide 14.1 9.2 Propyl alcohol 9.1 16.5


Isopropyl chloride 13.9 7.1 Propyl bromide 14.5 9.6
Isopropyl iodide 13.7 11.2 Propyl chloride 14.4 7.5

Kerosene 10.2 16.9 Propyl formate 13.1 9.7


Linseed oil, raw 7.5 27.2 Propyl iodide 14.1 11.6

Mercury 18.4 16.4 Sodium 16.4 13.9

Methanol, 100% 12.4 10.5 Sodium hydroxide, 50% 3.2 25.8


Methanol, 90% 12.3 11.8 Stannic chloride 13.5 12.8

Methanol, 40% 7.8 15.5 Succinonitrile 10.1 20.8

Methyl acetate 14.2 8.2 Sulfur dioxide 15.2 7.1


Methyl acrylate 13.0 9.5 Sulfuric acid, 110% 7.2 27.4

Methyl i-butyrate 12.3 9.7 Sulfuric acid, 100% 8.0 25.1


Methyl n-butyrate 13.2 10.3 Sulfuric acid, 98% 7.0 24.8

Methyl chloride 15.0 3.8 Sulfuric acid, 60% 10.2 21.3

Methyl ethyl 13.9 8.6 Sulfuryl chloride 15.2 12.4


ketone
Methyl formate 14.2 7.5 Tetrachloroethane 11.9 15.7

Methyl iodide 14.3 9.3 Thiophene 13.2 11.0


Methyl propionate 13.5 9.0 Titanium tetrachloride 14.4 12.3
Methyl propyl 14.3 9.5 Toluene 13.7 10.4
ketone

Methyl sulfide 15.3 6.4 Trichloroethylene 14.8 10.5


Naphthalene 7.9 18.1 Triethylene glycol 4.7 24.8

Nitric acid, 95% 12.8 13.8 Turpentine 11.5 14.9


Nitric acid, 60% 10.8 17.0 Vinyl acetate 14.0 8.8
Nitrobenzene 10.6 16.2 Vinyl toluene 13.4 12.0

Nitrogen dioxide 12.9 8.6 Water 10.2 13.0

Nitrotoluene 11.0 17.0 Xylene, ortho 13.5 12.1


Octane 13.7 10.0 Xylene, meta 13.9 10.6

Octyl alcohol 6.6 21.1 Xylene, para 13.9 10.9


Pentachloroethane 10.9 17.3      
Figure A.3-5. Heat capacity of liquids. (From R. H. Perry and C. H. Chilton, Chemical Engineers' Handbook, 5th
ed. New York: McGraw-Hill Book Company, 1973. With permission.)

[View full size image]

A.3-13. Thermal Conductivities of Liquids (k = βW/m · K)[*]

Liquid K k Liquid K k

Acetic acid     Ethylene glycol 273 0.265


  100% 293 0.171 Glycerol, 100% 293 0.284
  50% 293 0.346 n-Hexane 303 0.138
Ammonia 243–258 0.502     333 0.135
n-Amyl alcohol 303 0.163 Kerosene 293 0.149
    373 0.154     348 0.140

Benzene 303 0.159 Methyl alcohol    


    333 0.151   100% 293 0.215
Carbon 273 0.185   60% 293 0.329
tetrachloride
    341 0.163   20% 293 0.492

n-Decane 303 0.147   100% 323 0.197

    333 0.144 n-Octane 303 0.144


Ethyl acetate 293 0.175     333 0.140
Ethyl alcohol     NaCl brine    
  100% 293 0.182   25% 303 0.571

  60% 293 0.305   12.5% 303 0.589


  20% 293 0.486 Sulfuric acid    

  100% 323 0.151   90% 303 0.364

          60% 303 0.433


        Vaseline 332 0.183
Source: R. H. Perry and C. H. Chilton, Chemical Engineers' Handbook, 5th ed. New York: McGraw-Hill
Book Company, 1973. With permission.

[*]
 A linear variation with temperature may be assumed between the temperature limits given.

A.3-14. Heat Capacities of Solids (c p  = βkJ/kg · K)

Solid K cp Solid K cp

Alumina 373 0.84 Benzoic acid 293 1.243


  1773 1.147 Camphene 308 1.591
Asbestos   1.05 Caprylic acid 271 2.629
Asphalt   0.92 Dextrin 273 1.218

Brick, fireclay 373 0.829 Formic acid 273 1.800


  1773 1.248 Glycerol 273 1.382
Cement,   0.779 Lactose 293 1.202
portland
Clay   0.938 Oxalic acid 323 1.612
Concrete   0.63 Tartaric acid 309 1.202

Corkboard 303 0.167 Urea 293 1.340


Glass   0.84      
Magnesia 373 0.980      

  1773 0.787      

Oak   2.39      
Pine, yellow 298 2.81      
Porcelain 293–373 0.775      
Rubber,   2.01      
vulcanized

Steel   0.50      
Wool   1.361      
Source: R. H. Perry and C. H. Chilton, Chemical Engineers' Handbook, 5th ed. New York: McGraw-Hill
Book Company, 1973; National Research Council, International Critical Tables, Vol. V. New York:
McGraw-Hill Book Company, 1929; L. S. Marks, Mechanical Engineers' Handbook, 5th ed. New York:
McGraw-Hill Book Company, 1951; F. Kreith, Principles of Heat Transfer, 2nd ed. Scranton, Pa.:
International Textbook Co., 1965.

A.3-15. Thermal Conductivities of Building and Insulating Materials

   

Material t [*]  (°C) k(W/m·K)

Asbestos 577   0.151 (0°C) 0.168 0.190


(37.8°C) (93.3°C)

Asbestos sheets 889 51 0.166    

Brick, building   20 0.69    
Brick, fireclay     1.00 1.47 1.64
(200°C) (600°C) (1000°C)

Clay soil, 4% 1666 4.5 0.57    


H2 O

Concrete, 1:4 dry     0.762    
Corkboard 160.2 30 0.0433    

Cotton 80.1   0.055 (0°C) 0.061 0.068


(37.8°C) (93.3°C)

Felt, wool 330 30 0.052    


Fiber insulation 237 21 0.048    
board
Glass, window     0.52–1.06    
Glass fiber 64.1 30 0.0310 0.0414 0.0549
(−6.7°C) (37.8°C) (93.3°C)

Ice 921 0 2.25    

Magnesia, 85% 271   0.068 0.071 0.080


(37.8°C) (93.3°C) (204.4°C)

    208   0.059 0.062 0.066


(37.8°C) (93.3°C) (148.9°C)
Oak, across 825 15 0.208    
grain

Pine, across 545 15 0.151    


grain
Paper     0.130    

Polystyrene 16   0.040    
board
Polyurethane 24–40   0.023–    
sprayed foam 0.026
Rock wool 192   0.0317 0.0391 0.0486
(−6.7°C) (37.8°C) (93.3°C)

    128   0.0296 0.0395 0.0518


(−6.7°C) (37.8°C) (93.3°C)

Rubber, hard 1198 0 0.151    


Sand soil          
  4% H2 O 1826 4.5 1.51    

  10% H2 O 1922 4.5 2.16    

Sandstone 2243 40 1.83    

Snow 559 0 0.47    

Wool 110.5 30 0.036    


Source: L. S. Marks, Mechanical Engineers' Handbook, 5th ed. New York: McGraw-Hill Book
Company, 1951; W. H. McAdams, Heat Transmission, 3rd ed. New York: McGraw-Hill Book
Company, 1954; F. H. Norton, Refractories. New York: McGraw-Hill Book Company, 1949; National
Research Council, International Critical Tables. New York: McGraw-Hill Book Company, 1929; M. S.
Kersten, Univ. Minn. Eng. Ex. Sta., Bull. 28, June 1949; R. H. Heilman, Ind. Eng. Chem., 28, 782
(1936).

[*]
 Room temperature when none is noted.

A.3-16. Thermal Conductivities, Densities, and Heat Capacities of Metals

   

Material t(°C) k(W/m·K)

Aluminum 20 2707 0.896 202 (0°C) 206 215


(100°C) (200°C)

          230 (300°C)    
Brass (70–30) 20 8522 0.385 97 (0°C) 104 109
(100°C) (200°C)
Cast iron 20 7593 0.465 55 (0°C) 52 48
(100°C) (200°C)

Copper 20 8954 0.383 388 (0°C) 377 372


(100°C) (200°C)

Lead 20 11 370 0.130 35 (0°C) 33 31


(100°C) (200°C)

Steel 1%C 20 7801 0.473 45.3 (18°C) 45 45


(100°C) (200°C)

          43 (300°C)    
  308 stainless 20 7849 0.461 15.2 (100°C) 21.6  
(500°C)
  304 stainless 0 7817 0.461 13.8 (0°C) 16.3 18.9
(100°C) (300°C)
Tin 20 7304 0.227 62 (0°C)
59 57
(100°C) (200°C)
Source: L. S. Marks, Mechanical Engineers' Handbook, 5th ed. New York: McGraw-Hill Book
Company, 1951; E. R. G. Eckert and R. M. Drake, Heat and Mass Transfer, 2nd ed. New York:
McGraw-Hill Book Company, 1959; R. H. Perry and C. H. Chilton, Chemical Engineers' Handbook, 5th
ed. New York: McGraw-Hill Book Company, 1973; National Research Council, International Critical
Tables. New York: McGraw-Hill Book Company, 1929.

A.3-17. Normal Total Emmissivities of Surfaces

Surface K ε Surface K ε

Aluminum     Lead, unoxidized 400 0.057

  highly oxidized 366 0.20 Nickel, polished 373 0.072


  highly polished 500 0.039 Nickel oxide 922 0.59

    850 0.057 Oak, planed 294 0.90

Aluminum oxide 550 0.63 Paint    


Asbestos board 296 0.96   aluminum 373 0.52
Brass, highly 520 0.028   oil (16 different, 373 0.92–0.96
all colors)
  polished 630 0.031 Paper 292 0.924

Chromium, 373 0.075 Roofing paper 294 0.91


polished

Copper     Rubber (hard, 296 0.94


glossy)

  oxidized 298 0.78 Steel    

  polished 390 0.023   oxidized at 867 K 472 0.79

Glass, smooth 295 0.94   polished 373 0.074


stainless

Iron       304 stainless 489 0.44

  oxidized 373 0.74 Water 273 0.95


  Tin-plated 373 0.07   373 0.963

Iron oxide 772 0.85      


Source: R. H. Perry and C. H. Chilton, Chemical Engineers' Handbook, 5th ed. New York: McGraw-
Hill Book Company, 1973; W. H. McAdams, Heat Transmission, 3rd ed. New York: McGraw-Hill Book
Company, 1954; E. Schmidt, Gesundh.-Ing. Beiheft, 20, Reihe 1, 1 (1927).

A.3-18. Henry's Law Constants for Gases in Water (H × 10−4 )[*]

T                    

K °C CO2 CO C2 H6 C2 H4 He H2 H2 S CH4 N2 O2

273.2 0 0.0728 3.52 1.26 0.552 12.9 5.79 0.0268 2.24 5.29 2.55
283.2 10 0.104 4.42 1.89 0.768 12.6 6.36 0.0367 2.97 6.68 3.27
293.2 20 0.142 5.36 2.63 1.02 12.5 6.83 0.0483 3.76 8.04 4.01

303.2 30 0.186 6.20 3.42 1.27 12.4 7.29 0.0609 4.49 9.24 4.75

313.2 40 0.233 6.96 4.23   12.1 7.51 0.0745 5.20 10.4 5.35
Source: National Research Council, International Critical Tables, Vol. III. New York: McGraw-Hill Book
Company, 1929.
[*]
 pA = Hx A, pA = partial pressure of A in gas in atm, x A = mole fraction of A in liquid, H = Henry's law constant in atm/mole frac.

A.3-19. Equilibrium Data for SO2 –Water System

Partial Pressure of SO2  in Vapor, pA Mole Fraction SO2  in Vapor, y A; P =1


Mole Fraction SO2 (mm Hg) Atm
in Liquid, x A 20°C (293 K) 30°C (303 K) 20°C 30°C

0 0 0 0 0

0.0000562 0.5 0.6 0.000658 0.000790


0.0001403 1.2 1.7 0.00158 0.00223

0.000280 3.2 4.7 0.00421 0.00619


0.000422 5.8 8.1 0.00763 0.01065

0.000564 8.5 11.8 0.01120 0.0155


0.000842 14.1 19.7 0.01855 0.0259

0.001403 26.0 36 0.0342 0.0473


0.001965 39.0 52 0.0513 0.0685

0.00279 59 79 0.0775 0.1040

0.00420 92 125 0.121 0.1645

0.00698 161 216 0.212 0.284

0.01385 336 452 0.443 0.594


0.0206 517 688 0.682 0.905

0.0273 698   0.917  


Source: T. K. Sherwood, Ind. Eng. Chem., 17, 745 (1925).

A.3-20. Equilibrium Data for Methanol–Water System

Partial Pressure of Methanol in Vapor, pA
(mm Hg)
Mole Fraction Methanol in Liquid, x A 39.9°C (313.1 K) 59.4°C (332.6 K)

0 0 0
0.05 25.0 50
0.10 46.0 102

0.15 66.5 151


Source: National Research Council, International Critical Tables, Vol. III. New York: McGraw-Hill Book
Company, 1929.

A.3-21. Equilibrium Data for Acetone–Water System at 20°C (293 K)

Partial Pressure of Acetone in Vapor, pA
Mole Fraction Acetone in Liquid, x A (mm Hg)

0 0
0.0333 30.0
0.0720 62.8
0.117 85.4
0.171 103
Source: T. K. Sherwood, Absorption and Extraction. New York: McGraw-Hill Book Company, 1937.
With permission.

A.3-22. Equilibrium Data for Ammonia–Water System

Partial Pressure of NH3  in Vapor, pA Mole Fraction NH3  in Vapor, y A; P =1


(mm Hg) Atm
Mole Fraction
NH3 in Liquid, x A 20°C (293 K) 30°C (303 K) 20°C 30°C

0 0 0 0 0

0.0126   11.5   0.0151


0.0167   15.3   0.0201

0.0208 12 19.3 0.0158 0.0254

0.0258 15 24.4 0.0197 0.0321


0.0309 18.2 29.6 0.0239 0.0390

0.0405 24.9 40.1 0.0328 0.0527


0.0503 31.7 51.0 0.0416 0.0671

0.0737 50.0 79.7 0.0657 0.105

0.0960 69.6 110 0.0915 0.145


0.137 114 179 0.150 0.235

0.175 166 260 0.218 0.342

0.210 227 352 0.298 0.463

0.241 298 454 0.392 0.597


0.297 470 719 0.618 0.945
Source: J. H. Perry, Chemical Engineers' Handbook, 4th ed. New York: McGraw-Hill Book Company,
1963. With permission.

A.3-23. Equilibrium Data for Ethanol–Water System at 101.325 kPa (1 Atm)[*]

Vapor– Vapor–
Liquid Liquid
Equilibria, Equilibria,
Mass Mass Enthalpy Enthalpy
Fraction Fraction (btu/lbm  of (kJ/kg of
Temperature Ethanol Temperature Ethanol Temperature mixture) mixture)
Mass
°C °F xA yA °C °F xA yA °C °F Fraction Liquid Vapor Liquid Vapor

100.0 212 0 0 81.0 177.8 0.600 0.794 100.0 212 0 180.1 1150 418.9 2675
98.1 208.5 0.020 0.192 80.1 176.2 0.700 0.822 91.8 197.2 0.1 159.8 1082 371.7 2517

95.2 203.4 0.050 0.377 79.1 174.3 0.800 0.858 84.7 184.5 0.3 135.0 943 314.0 2193
91.8 197.2 0.100 0.527 78.3 173.0 0.900 0.912 82.0 179.6 0.5 122.9 804 285.9 1870
87.3 189.2 0.200 0.656 78.2 172.8 0.940 0.942 80.1 176.2 0.7 111.1 664 258.4 1544

84.7 184.5 0.300 0.713 78.1 172.7 0.960 0.959 78.3 173.0 0.9 96.6 526 224.7 1223

83.2 181.7 0.400 0.746 78.2 172.8 0.980 0.978 78.3 173.0 1.0 89.0 457.5 207.0 1064
82.0 179.6 0.500 0.771 78.3 173.0 1.00 1.00              
Source: Data from L. W. Cornell and R. E. Montonna, Ind. Eng. Chem., 25, 1331 (1933); and W. A. Noyes and R. R.
Warfel, J. Am. Chem. Soc., 23, 463 (1901), as given by G. G. Brown, Unit Operations. New York: John Wiley & Sons,
Inc., 1950. With permission.

[*]
 Reference state for enthalpy is pure liquid at 273 K or 0°C.

A.3-24. Acetic Acid–Water–Isopropyl Ether System, Liquid–Liquid Equilibria at 293 K or 20°C

Water Layer (wt %) Isopropyl Ether Layer (wt %)

Isopropyl Isopropyl
Acetic Acid Water Ether Acetic Acid Water Ether

0 98.8 1.2 0 0.6 99.4

0.69 98.1 1.2 0.18 0.5 99.3


1.41 97.1 1.5 0.37 0.7 98.9

2.89 95.5 1.6 0.79 0.8 98.4


6.42 91.7 1.9 1.93 1.0 97.1

13.30 84.4 2.3 4.82 1.9 93.3

25.50 71.1 3.4 11.40 3.9 84.7

36.70 58.9 4.4 21.60 6.9 71.5

44.30 45.1 10.6 31.10 10.8 58.1

46.40 37.1 16.5 36.20 15.1 48.7


Source: Trans. A.I.Ch.E., 36, 601, 628 (1940). With permission.

A.3-25. Liquid–Liquid Equilibrium Data for Acetone–Water–Methyl Isobutyl Ketone (MIK) System
at 298–299 K or 25–26°C

Composition Data (wt %) Acetone Distribution Data (wt %)

MIK Acetone Water Water Phase MIK Phase

98.0 0 2.00 2.5 4.5

93.2 4.6 2.33 5.5 10.0


77.3 18.95 3.86 7.5 13.5
71.0 24.4 4.66 10.0 17.5

65.5 28.9 5.53 12.5 21.3

54.7 37.6 7.82 15.5 25.5


46.2 43.2 10.7 17.5 28.2
12.4 42.7 45.0 20.0 31.2

5.01 30.9 64.2 22.5 34.0


3.23 20.9 75.8 25.0 36.5
2.12 3.73 94.2 26.0 37.5

2.20 0 97.8    
Source: Reprinted with permission from D. F. Othmer, R. E. White, and E. Trueger, Ind. Eng. Chem., 
33, 1240 (1941). Copyright by the American Chemical Society.
                             
                                                 
                                             
                                               
     

Appendix A.4. Physical Properties of Foods and
Biological Materials

A.4-1. Heat Capacities of Foods (Average c p  273-373 K or 0-100°C)

Material H2 O (wt %) c p  (kJ/kg · K )

Apples 75–85 3.73–4.02


Apple sauce   4.02[*]

Asparagus    
  Fresh 93 3.94[†]

  Frozen 93 2.01[‡]

Bacon, lean 51 3.43

Banana purée   3.66[§]

Beef, lean 72 3.43

Bread, white 44–45 2.72–2.85


Butter 15 2.30[¶]

Cantaloupe 92.7 3.94[†]

Carrot 88.2 3.81–3.94

Cheese, Swiss 55 2.68[†]

Corn, sweet    
  Fresh   3.32[†]

  Frozen   1.77[‡]

Cream, 45–60% fat 57–73 3.06–3.27

Cucumber 97 4.10
Eggs    

  Fresh   3.18[†]

  Frozen   1.68[‡]

Egg yolk 4.00 2.81


Fish, cod    

  Fresh 70 3.18
  Frozen 70 1.72[‡]

Flour 12–13.5 1.80–1.88


Ice 100 1.958[||]
Ice cream    
  Fresh 58–66 3.27[†]

  Frozen 58–66 1.88[‡]

Lamb 70 3.18[*]

Macaroni 12.5–13.5 1.84–1.88


Milk, cows'    

  Whole 87.5 3.85


  Skim 91 3.98–4.02
Olive oil   2.01[**]

Oranges    
  Fresh 87.2 3.77[†]

  Frozen 87.2 1.93[‡]

Peas, air-dried 14 1.84
Peas, green    

  Fresh 74.3 3.31[†]

  Frozen 74.3 1.76[‡]

Pea soup   4.10

Plums 75–78 3.52


Pork    

  Fresh 60 2.85[†]

  Frozen 60 1.34[‡]

Potatoes 75 3.52

Poultry    

  Fresh 74 3.31[†]

  Frozen 74 1.55[‡]

Sardines 57.4 3.01


Sausage, franks    
  Fresh 60 3.60[†]

  Frozen 60 2.35[‡]

String beans    
  Fresh 88.9 3.81[†]

  Frozen 88.9 1.97[‡]

Tomatoes 95 3.98[†]

Veal   63 3.22

Water   100 4.185[**]


Source: W. O. Ordinanz, Food Ind., 18, 101 (1946); G. A. Reidy, Department of
Food Science. Michigan State University, 1968; S. E. Charm, The
Fundamentals of Food Engineering, 2nd ed. Westport, Conn.: Avi Publishing
Co., Inc., 1971; R. L. Earle, Unit Operations in Food Processing. Oxford:
Pergamon Press, Inc., 1966; ASHRAE, Handbook of Fundamentals. New York:
ASHRAE, 1972, 1967; H. C. Mannheim, M. P. Steinberg, and A. I. Nelson,
Food Technol., 9, 556 (1955).

[*]
 32.8°C.

[†]
 Above freezing.

[‡]
 Below freezing.

[§]
 24.4°C.

[¶]
 4.4°C.

[| ]
 20°C.

[**]
 20°C.
                             
                                                 
                                             
                                               
     

A.4­2. Thermal Conductivities, Densities, and Viscosities of Foods

A.4-2. Thermal Conductivities, Densities, and Viscosities of Foods

μ [(Pa · s)103 ,
Material H2 O (wt %) Temperature (K) k (W/m · K) ρ (kg/m 3 ) or cp]

Apple juice 87.4 293.2 0.559    


Apple sauce   295.7 0.692    

Apple 85.6 275.2–309.2 0.393    


Beef, lean 78.8 308.2 0.458    

Beef, fat     0.19    

Butter 15 277.6 0.197 998  

Cantaloupe     0.571    
Egg          

  white   309.2 0.577    


  yolk   306.2 0.338    

Fish          

  Fresh   273.2 0.431    


  Frozen   263.2 1.22    

Flour, wheat 8.8   0.450    


Honey 12.6 275.4 0.50    

Ice 100 273.2 2.25    


    100 253.2 2.42    
Lamb 71 278.8 0.415    
Milk          

  Whole   293.2   1030 2.12


  Skim   274.7 0.538    
      298.2   1041 1.4

Oil          
  Cod liver   298.2   924  

  Corn   288.2   921  

  Olive   293.2 0.168 919 84


  Peanut   277.1 0.168    
  Soybean   303.2   919 40
Oranges 61.2 303.5 0.431    

Pears   281.9 0.595    


Pork, lean          
  Fresh 74 275.4 0.460    

  Frozen   258.2 1.109    


Potatoes          

  Raw     0.554    
  Frozen   260.4 1.09 977  

Salmon          
  Fresh 67 277.1 0.50    
  Frozen 67 248.2 1.30    

Sucrose solution 80 294.3   1073 1.92


Turkey          
  Fresh 74 276.0 0.502    

  Frozen   248.2 1.675    


Veal          

  Fresh 75 335.4 0.485    

  Frozen 75 263.6 1.30    

Water 100 293.2 0.602    


    100 273.2 0.569    
Source: R. C. Weast, Handbook of Chemistry and Physics, 48th ed. Cleveland: Chemical Rubber Co.,
Inc., 1967; C. P. Lentz, Food Technol., 15, 243 (1961); G. A. Reidy, Department of Food Science,
Michigan State University, 1968; S. E. Charm, The Fundamentals of Food Engineering, 2nd ed.
Westport, Conn.: Avi Publishing Co., Inc., 1971; R. Earle, Unit Operations in Food Processing. Oxford:
Pergamon Press, 1966; R. H. Perry and C. H. Chilton, Chemical Engineers' Handbook, 5th ed. New
York: McGraw-Hill Book Company, 1973; V. E. Sweat, J. Food Sci., 39, 1080 (1974).
                             
                                                 
                                             
                                               
     

Appendix A.5. Properties of Pipes, Tubes, and Screens

A.5-1. Dimensions of Standard Steel Pipe

Wall Inside Inside Cross-


Outs ide Diameter Thickness Diameter Sectional Area
Nominal Pipe Schedule
Size (in.) in. mm Number in. mm in. mm ft 2 m 2  ×104

0.405 10.29 40 0.068 1.73 0.269 6.83 0.00040 0.3664

      80 0.095 2.41 0.215 5.46 0.00025 0.2341


0.540 13.72 40 0.088 2.24 0.364 9.25 0.00072 0.6720

      80 0.119 3.02 0.302 7.67 0.00050 0.4620


0.675 17.15 40 0.091 2.31 0.493 12.52 0.00133 1.231

      80 0.126 3.20 0.423 10.74 0.00098 0.9059

0.840 21.34 40 0.109 2.77 0.622 15.80 0.00211 1.961

      80 0.147 3.73 0.546 13.87 0.00163 1.511

1.050 26.67 40 0.113 2.87 0.824 20.93 0.00371 3.441

      80 0.154 3.91 0.742 18.85 0.00300 2.791

1 1.315 33.40 40 0.133 3.38 1.049 26.64 0.00600 5.574

      80 0.179 4.45 0.957 24.31 0.00499 4.641


1.660 42.16 40 0.140 3.56 1.380 35.05 0.01040 9.648

      80 0.191 4.85 1.278 32.46 0.00891 8.275

1.900 48.26 40 0.145 3.68 1.610 40.89 0.01414 13.13

      80 0.200 5.08 1.500 38.10 0.01225 11.40


2 2.375 60.33 40 0.154 3.91 2.067 52.50 0.02330 21.65

      80 0.218 5.54 1.939 49.25 0.02050 19.05

2.875 73.03 40 0.203 5.16 2.469 62.71 0.03322 30.89

      80 0.276 7.01 2.323 59.00 0.02942 27.30

3 3.500 88.90 40 0.216 5.49 3.068 77.92 0.05130 47.69


      80 0.300 7.62 2.900 73.66 0.04587 42.61
4.000 101.6 40 0.226 5.74 3.548 90.12 0.06870 63.79

      80 0.318 8.08 3.364 85.45 0.06170 57.35

4 4.500 114.3 40 0.237 6.02 4.026 102.3 0.08840 82.19


      80 0.337 8.56 3.826 97.18 0.07986 74.17
5 5.563 141.3 40 0.258 6.55 5.047 128.2 0.1390 129.1

      80 0.375 9.53 4.813 122.3 0.1263 117.5

6 6.625 168.3 40 0.280 7.11 6.065 154.1 0.2006 186.5


      80 0.432 10.97 5.761 146.3 0.1810 168.1
8 8.625 219.1 40 0.322 8.18 7.981 202.7 0.3474 322.7

      80 0.500 12.70 7.625 193.7 0.3171 294.7

A.5-2. Dimensions of Heat-Exchanger Tubes

Wall Inside Cross-
Outside Diameter Thickness Inside Diameter Sectional Area
BWG
in. mm Number in. mm in. mm ft 2 m 2  × 104

15.88 12 0.109 2.77 0.407 10.33 0.000903 0.8381

    14 0.083 2.11 0.459 11.66 0.00115 1.068

    16 0.065 1.65 0.495 12.57 0.00134 1.241

    18 0.049 1.25 0.527 13.39 0.00151 1.408

19.05 12 0.109 2.77 0.532 13.51 0.00154 1.434

    14 0.083 2.11 0.584 14.83 0.00186 1.727

    16 0.065 1.65 0.620 15.75 0.00210 1.948

    18 0.049 1.25 0.652 16.56 0.00232 2.154

22.23 12 0.109 2.77 0.657 16.69 0.00235 2.188

    14 0.083 2.11 0.709 18.01 0.00274 2.548

    16 0.065 1.65 0.745 18.92 0.00303 2.811


    18 0.049 1.25 0.777 19.74 0.00329 3.060
1 25.40 10 0.134 3.40 0.732 18.59 0.00292 2.714

    12 0.109 2.77 0.782 19.86 0.00334 3.098


    14 0.083 2.11 0.834 21.18 0.00379 3.523

    16 0.065 1.65 0.870 22.10 0.00413 3.836


31.75 10 0.134 3.40 0.982 24.94 0.00526 4.885

    12 0.109 2.77 1.032 26.21 0.00581 5.395


    14 0.083 2.11 1.084 27.53 0.00641 5.953
    16 0.065 1.65 1.120 28.45 0.00684 6.357

38.10 10 0.134 3.40 1.232 31.29 0.00828 7.690

    12 0.109 2.77 1.282 32.56 0.00896 8.326

    14 0.083 2.11 1.334 33.88 0.00971 9.015


2 50.80 10 0.134 3.40 1.732 43.99 0.0164 15.20

    12 0.109 2.77 1.782 45.26 0.0173 16.09


A.5-3. Tyler Standard Screen Scale

Sieve Clear Opening Nominal Wire Diameter

Mesh in. mm mm in.

1.050 in. 1.050 26.67 3.76 0.148


0.833 in 0.833 22.43 3.43 0.135

0.742 in. 0.742 18.85 3.43 0.135


0.624 in 0.624 15.85 3.05 0.120

0.525 in. 0.525 13.33 2.67 0.105


0.441 in. 0.441 11.20 2.67 0.105

0.371 in. 0.371 9.423 2.34 0.092


 mesh 0.312 7.925 2.24 0.088

3 mesh 0.263 6.680 1.78 0.070

 mesh 0.221 5.613 1.65 0.065

4 mesh 0.185 4.699 1.65 0.065

5 mesh 0.156 3.962 1.12 0.044

6 mesh 0.131 3.327 0.914 0.036

7 mesh 0.110 2.794 0.833 0.0328


8 mesh 0.093 2.362 0.813 0.032

9 mesh 0.078 1.981 0.838 0.033

10 mesh 0.065 1.651 0.889 0.035


12 mesh 0.055 1.397 0.711 0.028

14 mesh 0.046 1.168 0.635 0.025

16 mesh 0.0390 0.991 0.597 0.0235


20 mesh 0.0328 0.833 0.437 0.0172
24 mesh 0.0276 0.701 0.358 0.0141

28 mesh 0.0232 0.589 0.318 0.0125

32 mesh 0.0195 0.495 0.300 0.0118


35 mesh 0.0164 0.417 0.310 0.0122
42 mesh 0.0138 0.351 0.254 0.0100

48 mesh 0.0116 0.295 0.234 0.0092

60 mesh 0.0097 0.246 0.178 0.0070


65 mesh 0.0082 0.208 0.183 0.0072
80 mesh 0.0069 0.175 0.142 0.0056

100 mesh 0.0058 0.147 0.107 0.0042

115 mesh 0.0049 0.124 0.097 0.0038


150 mesh 0.0041 0.104 0.066 0.0026

170 mesh 0.0035 0.088 0.061 0.0024


200 mesh 0.0029 0.074 0.053 0.0021
250 mesh 0.0025 0.063 0.044 0.0017

270 mesh 0.0021 0.053 0.037 0.0015


325 mesh 0.0017 0.044 0.030 0.0012

400 mesh 0.0015 0.037 0.025 0.0010


                             
                                                 
                                             
                                               
     

Notation
SI units are given first (followed by English and/or cgs units).

a shape factor, dimensionless

a particle radius, m (ft)
a area, m2  (ft2 ); also m2  area/m3  volume bed or packing (ft2 /ft3 )

ae acceleration from centrifugal force, m/s2  (ft/s2 )

aν specific surface area of particle, m−1  (ft−1 )

A cross-sectional area, m2  (ft2 , cm2 ); also area, m2  (ft2 )

A absorption factor = L/mV, dimensionless; also filter area, m2  (ft2 )

Am membrane area, cm2 , m2  (ft2 )

Aw solvent permeability constant, kg/s · m2  · atm

As solute permeability constant, m/s (ft/h)

b length, m (ft, cm)

B length of side in structured packing, cm (in.)
B flow rate of dry solid, kg/h (lb /h); also filtration constant, s/m3  (s/ft3 )
m

B physical property of membrane, atm−1

Bo nucleation rate, number of nuclei/h · L

c concentration, kg/m3 , kg mol/m3  (lb /ft3 , g mol/cm3 )


m

c concentration of absorbate in fluid, kg/m3  (lb /ft3 )


m

cA concentration of A, kg mol/m3  (lb mol/ft3 , g mol/cm3 )

cb break-point concentration, kg/m3  (lb /ft3 )


m

cg concentration of solute in gel, kg solute/m3  (lb /ft3 , g/cm3 )


m

cs concentration of solute at surface of membrane, kg solute/m3  (lb /ft3 ,


m
g/cm3 )

cS concentration of A in solid, kg mol A/m3  (lb /ft3 , g mol/cm3 )


m

cS concentration of solids in slurry, kg/m3  (lb /ft3 )


m

cS humid heat, kJ/kg dry air · K (btu/lbm dry air · °F)

cx concentration of solids in slurry, mass frac

cp heat capacity at constant pressure, J/kgK, · kJ/kgK, · kJ/kg mol · K (btu/lbm ·
°F, cal/g · °C)
cw2 concentration of solvent in permeate, kg solvent/m3

deviation of concentration from mean concentration  , kg mol/m3

cp concentration of P, kg P/m3

cν heat capacity at constant volume, J/kg · K

C filtration constant, N/m2  (lb /ft2 ); also, number of components


f

C fluid heat capacity, W/K (btu/h · °F)
C height of bottom of agitator above tank bottom, m (ft)
C total concentration in liquid solution, equiv/L

Cp pitot tube coefficient, dimensionless

CD drag coefficient, dimensionless

Cν, Co , Cn Venturi coefficient, orifice coefficient, flow nozzle coefficient, dimensionless

dp packing diameter, mm (in.)

do hole diameter, ft

D molecular diffusivity, m2 /s (ft2 /h, cm2 /s); also diameter, m (ft)

D decimal reduction time, min; also distillate flow rate, kg/h, kg mol/h (lbm/h)

DAB molecular diffusivity, m2 /s (ft2 /h, cm2 /s)

molecular diffusivity in dilute solution, cm2 /s (ft2 /h)

Dp particle diameter, m (ft)

DKA Knudsen diffusivity m2 /s (ft2 /h, cm2 /s)

DNA transition-region diffusivity, m2 /s (ft2 /h, cm2 /s)

DA eff effective diffusivity, m2 /s (ft2 /h, cm2 /s)

Dp,m effective mean diameter for mixture, m (ft)

Da diameter of agitator, m (ft)

Dt diameter of tank, m (ft)

Dpc critical diameter, m (ft)

DAP diffusivity of A in protein solution, m2 /s

D+ molecular diffusivity of cation, cm2 /s

D− molecular diffusivity of anion, cm2 /s

E height of element in structured packing, cm (in.)
E activation energy, J/kg mol (cal/g mol)
E energy for size reduction, kW · h/ton; also tray efficiency, dimensionless

E total energy, J/kg (ft · lbf/lbm)

E fraction unaccomplished change, dimensionless
E emitted radiation energy, W/m2  (btu/h · ft2 )

E axial dispersion coefficient, m2 /s (ft2 /h)

EBλ monochromatic emissive power, W/m3  (btu/h · ft3 )


Eo fraction or % tray efficiency

ƒ fraction of feed vaporized; also cycle fraction, dimensionless
ƒ fanning friction factor, dimensionless
ƒp relative mass-transfer coefficient, dimensionless

ƒt mixing factor, dimensionless

F number of degrees of freedom

F frictional loss, J/kg (ft · lbf/lbm)

F flow rate, kg/h, kg mol/h (lbm/h)

F force, N (lbf, dyn)

FT correction factor for temperature difference, dimensionless

F0 process time at 121.1°C(250°F), min

Fp packing factor, m−1 (ft−1 )

geometric view factor for gray surfaces, dimensionless

F12 geometric view factor, dimensionless

g standard acceleration of gravity (see Appendix A.1)

gc gravitional conversion factor (see Appendix A.1)

G mass velocity = νρ, kg/s · m2 , kg/h · m2  (lb /h · ft2 )


m

G growth constant, mm/h
G' mass velocity = ν'ρ, kg/s · m2 , kg/h · m2  (lb /h · ft2 )
m

G irradiation on a body, W/m2  (btu/h · ft2 )

h constant spacing in x for Simpson's rule

h head, J/kg (ft · lbf/lbm); also height of fluid, m (ft)

h heat-transfer coefficient, W/m2  · K (btu/h · ft2  · °F)

h enthalpy of liquid, J/kg, kJ/kg, kJ/kg mol (btu/lbm)

h height of triangle in structured packing, cm (in.)

hƒg latent heat of vaporization, J/kg, kJ/kg (btu/lbm)

hc contact resistance coefficient, W/m2  · K (btu/h · ft2  · °F)

H distance, m (ft)

H Henry's law constant, atm/mol frac

H head, J/kg (ft · lbf/lbm); also height of fluid, m (ft)

H enthalpy, J/kg, kJ/kg, kJ/kg mol (btu/lbm); also enthalpy kJ/kg dry air (btu/lbm
dry air)

H humidity, kg water vapor/kg dry air (lb water vapor/lb dry air)
H enthalpy of vapor, J/kg, kJ/kg, kJ/kg mol (btu/lbm)

H equilibrium relation, kg mol/m3  · atm

H bed length, m (ft); also effective length of spindle, m (ft)
H height of packing, m (ft)
H' enthalpy, kJ/kg dry solid (btu/lbm); also enthalpy, kJ/kg dry air (btu/lbm dry
air)
HB length of bed used up to break point, m (ft)

HG, HL , Hy, Hoy HOG, height of transfer unit, m (ft)


HOL , Hx, Hox

HP, HR percentage humidity, percentage relative humidity, respectively

HT total bed length, m (ft)

HUNB length of unused bed, m (ft)

HETS height of equilibrium stage, m (ft)
HETP height equivalent of packed tower equal to one theoretical plate, m (ft)
i unit vector along x axis

I intensity of turbulence, dimensionless; also current, amp
IB radiation intensity of black body, W/m2  · sr (btu/h · ft2  · sr)

Iλ intensity of radiation, W/m2  (btu/h · ft2 )

j unit vector along y axis
J width of baffle, m (ft)

jA mass flux of A relative to mass average velocity, kg/s · m2

mass flux of A relative to molar average velocity, kg/s · m2

JA molar flux of A relative to mass average velocity, kg mol/s · m2

molar flux vector of A relative to molar average velocity, kg mol/s · m2  (lb
mol/h · ft2 , g mol/s · cm2 )

JD' JH mass-transfer and heat-transfer factors, dimensionless

k unit vector along z axis

k, k' reaction velocity constant, h−1 , min−1 , or s−1

k thermal conductivity, W/m · K (btu/h · ft · °F)
k reaction velocity constant, h−1 , min−1 , or s−1

first-order heterogeneous reaction velocity constant, m/s (cm/s)

,  ,  ,  , . . . mass-transfer coefficient, kg mol/s · m2  · conc diff (lb mol/h · ft2  · conc diff, g


kc kG kx
mol/s · cm2  · conc diff); kg mol/s · m2  · Pa, kg mol/s · m2  · atm (lb mol/h · ft2
· atm). (See Table 7.2-1.)
kc mass-transfer coefficient, m/s (ft/ h, cm/s)

mass transfer coefficient defined by Eq. (7.2-23), m/s (ft/h, cm/s)

kGa, kxa, kya, . . . volumetric mass-transfer coefficient, kg mol/s · m3  · conc diff (lb mol/h · ft3  ·


conc diff, g mol/s · cm3  · conc diff); kg mol/s · m3  · Pa

ks surface reaction coefficient, kg mol/s · m2  · mol frac

,  wall constants, dimensionless
kw

overall mass-transfer coefficient, kg mol/s · m2  · mol frac (lb mol/h · ft2  · mol


,  frac, g mol/s · cm2  · mol frac)

K consistency index, N · sn /m2  (lb  · sn /ft2 )


f

K overall mass transfer coefficient in crystallization, kg mol/s · m2  · mol frac

Kν constant in allowable vapor velocity equation, ft/s
K relative molar selectivity coefficient, dimensionless

KAB equilibrium constant for exchange of ions A and B

K1 constant in Eq. (3.1-39), m/s (ft/s)

K', Ks equilibrium distribution coefficient, dimensionless

K″ consistency index, N · sn'/m2  (lb  · sn'/ft2 )


f

K equilibrium distribution coefficient, dimensionless
Kp filtration constant, s/m6  (s/ft6 )

KV filtration constant, N/m5  (lb /ft5 )


f

Kc, Kex, Kƒ contraction, expansion, fitting loss coefficient, dimensionless

L length, m (ft); also amount, kg, kg mol (lb ); also kg/h · m2
m

L liquid flow rate, kg/h, kg mol/h (lbm/h)

L crystal size, mm
L residue or reject flow rate, cm3  (STP)/s, m3 /s (ft3 /h)

L Prandtl mixing length, m (ft)

L mean beam length, m (ft)
La average crystal size, mm

Ld predominant crystal size, mm

Lƒ feed flow rate, cm3  (STP)/s, m3 /s (ft3 /h)

LS dry solid weight, kg dry solid (lbm dry solid)

L' flow rate, kg inert/h, kg mol inert/h (lbm inert/h)

m, m', m'' slope of equilibrium line, dimensionless
m flow rate, kg/s, kg/h (lbm/s)

m dimensionless ratio = k/hx1 ; also, position m

m parameter in Table 7.1-1, dimensionless; also position parameter
m ratio, kg wet cake/kg dry cake (lb wet cake/lb dry cake)

M molecular weight, kg/kg mol (lbm/lb mol)

M total mass, kg (lb ); also parameter = (Δx)2 /αΔt, dimensionless


m

M modulus = (Δx)2 /D Δt, dimensionless
AB

M flow rate, kg/h, kg mol/h (lbm/h)

M amount of adsorbent, kg(lbm)

average molecular weight of liquid
ML

n number of theoretical stages

n number of crystals/(L · mm)
n exponent, dimensionless; also flow behavior index, dimensionless
n' slope of line for power-law fluid, dimensionless

n position parameter; also dimensionless ratio = ×/×1

n total amount, kg mol (lb mol, g mol)

no zero-size population density, number/(L · mm)

nA flux of A relative to stationary coordinates, kg/s · m2

n+ valence of cation

n− valence of anion

N rpm or rps; also number of radiation shields

N parameter = h Δx/k, dimensionless; also number of viable organisms,
dimensionless
N total flux relative to stationary coordinates, kg mol/s · m2  (lb mol/h · ft2 , g
mol/s · cm2 )

N modulus = kcΔx/DAB, dimensionless; also number of stages

N number of crystals/L

N concentration of solid B, kg solid B/kg solution (lb solid B/lb solution)
N number of equal temperature subdivisions, dimensionless

NT number of tubes in parallel

Ns solute flux, kg/s · m2  (lb /h · ft2 )


m

Nw solvent flux, kg solvent/s · m2  (lb /h · ft2 )


m

residual defined by Eq. (6.6-3), kg mol/m3  (lb mol/ft3 )

NA molar flux vector of A relative to stationary coordinates, kg mol/s · m2  (lb
mol/h · ft2 , g mol/s · cm2 )

mass transfer of A relative to stationary coordinates, kg mol/s (lb mol/h, g
mol/s)
(NPSH) net positive suction head, m (ft)
NG, NL , NOG, NOL number of transfer units, dimensionless

NGr Grashof number defined in Eq. (4.7-4), dimensionless

NBi Biot number = h×1 /k, dimensionless

NGz Graetz number defined in Eq. (4.12-3), dimensionless

NGr,δ Grashof number defined in Eq. (4.7-5), dimensionless

NMa Mach number defined by Eq. (2.11-15), dimensionless

NPe Peclet number = NRe NPr, dimensionless

NNu,δ Nusselt number = hδ/k, dimensionless
NFr Froude number = ν2 /gL, dimensionless

NKn Knudsen number =   dimensionless

NNu Nusselt number = hL/k, dimensionless

NNu,x Nusselt number = hxx/k, dimensionless

NPr Prandtl number = cp μ/k, dimensionless

NRe Reynolds number = Dνρ/μ, dimensionless

Reynolds number =  , dimensionless

NRe,gen Reynolds number defined by Eq. (3.5-11), dimensionless

NRe,L Reynolds number = Lν ∞ρ/μ, dimensionless

NRe,x Reynolds number = xν ∞ρ/μ, dimensionless

Reynolds number defined by Eq. (3.5-39) dimensionless

NRe,p Reynolds number defined by Eq. (3.1-15), dimensionless

NRe,mf Reynolds number at minimum fluidization defined by Eq. (3.1-35),
dimensionless

NEu Euler number = ρ/ρν2 , dimensionless

NSc Schmidt number = μ/ρDAB, dimensionless

NSh Sherwood number =  , dimensionless


D/DAB

NP power number defined by Eq. (3.4-2), dimensionless

NQ Flow number, dimensionless

NSt Stanton number =  , dimensionless


NTU number of transfer units, dimensionless

O flow rate, kg/h, kg mol/h (lbm/h)

P pressure, N/m2 , Pa (lb /ft2 , atm, psia, mm Hg)


f

pνp vapor pressure of fluid, N/m2  (lb /ft2 )


f

pA partial pressure of A, N/m2 , Pa (lb /ft2 , atm, psia, mm Hg)


f

ps pressure at STP, Pa

pBM log mean inert partial pressure of B in Eq. (6.2-21), N/m2 , Pa (lb /ft2 , atm,


f
psia, mm Hg)
ph total pressure in high-pressure side (feed), cm Hg, Pa (atm)

pl total pressure in low-pressure side (permeate) cm Hg, Pa (atm)

pM permeance in solid, m/s (ft/h)

P parameter in Eq. (5.5-12), dimensionless

P total pressure, N/m2 , Pa (lb /ft2 , atm, psia, mm H)


f

P power, W (ft · lbf/s, hp)

P flow rate, kg/h, kg/min; also number of phases at equilibrium
P momentum vector, kg · m/s (lbm · ft/s)

PA vapor pressure of pure A, N/m2 , Pa (lb /ft2 , atm, psia, mm Hg)


f

permeability of A, cm3  (STP) · cm/s · cm2 cm Hg

/ permeance of A, cm3  (STP)/s · cm2  · cm Hg, m3  (STP)/s · m2  · Pa


t
Pw solvent membrane permeability, kg solvent/s · m · atm (lbm/h · ft · atm)

PM permeability, m3 (STP)/(s · m2  C.S. · atm/m)

q heat-transfer rate, W (btu/h); also net energy added to system, W (btu/h);
also J (btu)

q flow rate, m3 /s (ft3 /s)

q heat flux vector, W/m2  (btu/h · ft2 )

rate of heat generation, W/m3  (btu/h · ft3 )

q feed condition defined by Eq. (11.4-12)
q' flow rate in Darcy's law, cm3 /s

q kg adsorbate/kg adsorbent (lbm/lbm)

qc condenser duty, kJ/h, kW (btu/h)

, residual defined by Eq. (4.5-11), K (°F)
m

qR reboiler duty, kJ/h, kW (btu/h)

qAR concentration of A in bulk bed volume, equiv/L volume

Q total concentration of A and B in bulk bed volume, equiv/L volume
Q outflow in crystallizer, L/h

Q circulation rate, m3 /s (ft3 /h)

Q amount absorbed, kg mol/m2 ; also heat loss, W (btu/h); also heat absorbed,
J/kg (btu/lbm, ft · lbf/lbm)

r radius, m (ft)
r ratio of pressures, ρl/ρh

rA rate of generation, kg A/s · m3  (lb A/h · ft3 )


m

rH hydraulic radius, m (ft)

(r2 )cr critical value of radius, m (ft)

R rate of drying, kg/h · m2  (lb /h · ft2 )


m

R solute rejection, dimensionless
R scaleup ratio, dimensionless

R radius, m (ft); also resistance, K/W (h · °F/btu)
R parameter in Eq. (5.5-12), dimensionless; also resistance, ohms

R gas constant (see Appendix A.1); also reflux ratio = Ln /D, dimensionless

RA rate of generation, kg mol A/s · m3  (lb mol A/h · ft')

Rb radius of spindle, m (ft)
Rc radius of outer cylinder, m (ft)

Rc contact resistance, K/W (h · °F/btu)

Rg gel layer resistance, s · m2  · atm/kg

Rm resistance of filter medium, m−1 (ft−1 )

Rm membrane resistance, m2 /kg

Rc cake resistance, m2 /kg

Ri rate of generation of i, kg/s (lbm/h)

R× x component of force, N (lbf, dyn)

s compressibility constant, dimensionless
s mean surface renewal factors, s−1

S conduction shape factor, m (ft)

S solubility of a gas, m3  solute(STP)/m3  solid · atm [cc solute(STP)/cc solid ·


atm]
S distance between centers, m (ft); also steam flow rate, kg/h, kg mol/h (lbm/h)

S volume of feed solution, m3  (ft3 )

S cross-sectional area of tower, m2  (ft2 ); also stripping factor, 1/A

S length of side in structured packing, cm (in.)

S0 specific surface area, m2 /m3  volume (ft2 /ft3  volume)

Sp surface area of particle, m2  (ft2 )

t fin thickness, m (ft)

t time, s, min, or h

t temperature, K, °C (°F)

t membrane thickness, cm, m (ft)

tb break-point time, h

tt time equivalent to total capacity, h

tT mixing time, s

tu time equivalent to usable capacity up to break-point time, h

T tray spacing, m (ft)

T torque, kg · m2 /s2

T temperature. K, °C (°F, °R); also feed rate, ton/min

TS temperature at STP, K

T' deviation of temperature from mean temperature  , K (°F)

average velocity, m/s (ft/s)

U overall heat-transfer coefficient, W/m2  · K (btu/h · ft2  · °F)

U internal energy, J/kg (btu/lbm)

ν velocity, m/s (ft/s)
ν velocity vector, m/s (ft/s)
νA velocity of A relative to stationary coordinates, m/s (ft/s, cm/s)

νAd diffusion velocity of A relative to molar average velocity, m/s (ft/s, cm/s)

νp volume of particle, mm3 /particle

ν'mb minimum bubbling velocity, m/s (ft/s)

νM molar average velocity of stream relative to stationary coordinates, m/s (ft/s,
cm/s)
νH humid volume, m3 /kg dry air (ft3 /lb  dry air)
m

νt terminal settling velocity, m/s (ft/s)

ν+ dimensionless velocity defined by Eq. (3.10-34)

ν* velocity defined by Eq. (3.10-42), dimensionless

deviation of velocity in   direction from mean velocity  , m/s (ft/s)


x

ν' superficial velocity based on cross section of empty tube, m/s (ft/s, cm/s)
velocity at minimum fluidization, m/s (ft/s)

terminal settling velocity, m/s (ft/s)

VA solute molar volume, m3 /kg mol

V flow rate, kg/h, kg mol/h, m3 /s (lb /h, ft3 /s)


m

V volume, m3  (ft3 , cm3 ); also specific volume, m3 /kg (ft3 /lb )


m

V volume of crystallizer, L

V velocity, m/s (ft/s); also total amount, kg, kg mol (lbm)

V flow rate of permeate, cm3  (STP)/s, m3 /s (ft3 /h)

Vp outlet permeate flow rate, m3  (STP)/s, m3 /s (ft3 /h)

V' inert flow rate, kg/h, kg/s, kg mol/h (lbm/h)

VC, VD superficial velocities of continuous and dispersed phase, ft/h

wA mass fraction of A

work done on surroundings, W (ft · lbf/s)

W free water, kg (lbm)

mechanical shaft work done on surroundings, W (ft · lbf/s)

W flow rate, kg/h, kg mol/h (lbm/h)

W work done on surroundings, J/kg(ft · lbf/lbm)

W weight of wet solid, kg (lbm)

W height or width, m (ft); also power, W (hp); also mass dry cake, kg (lbm)

W width of paddle, m (ft)

WS mechanical shaft work done on surroundings, J/kg(ft · lbf/lbm)

Wp shaft work delivered to pump, J/kg(ft · lbf/lbm)
(1 − Wƒ ) cumulative wt fraction

× distance in x direction, m (ft)
× mass fraction or mole fraction; also fraction remaining of original free
moisture

×A mass fraction of A, mole fraction of A, dimensionless

inert mole ratio, mol B/mol inert

xƒ mole fraction of A in feed, dimensionless

xo mole fraction of A in reject, dimensionless

xoM mole fraction of minimum reject concentration, dimensionless

xBM log mean mole fraction of inert or stagnant B given in Eq. (6.3-4)

(1 − ×A)*M log mean inert mole fraction defined by Eq. (10.4-27)

(1 − ×A)iM log mean inert mole fraction defined by Eq. (10.4-7)

X particle size, m (ft); also parameter =  , dimensionless

X parameter = Dt/×2 , dimensionless; also free moisture, kg water/kg dry solid
(lb water/lb dry solid)
y distance in y direction, m (ft); also mole fraction

y' mole fraction in permeate at interface, dimensionlesss
yA mass fraction of A or mole fraction of A; also kg A/kg solution (lb A/lb
solution)

yBM log mean mole fraction of inert or stagnant B given in Eq. (7.2-11)

y+ dimensionless number defined by Eq. (3.10-35)

yp mole fraction of A in permeate, dimensionless

(y − yi)M log mean driving force defined by Eq. (10.6-27)

(1 − yA)iM log mean inert mole fraction defined by Eq. (10.4-6)

(y − y*)M log mean driving force defined by Eq. (10.6-28)

Y temperature ratio defined by Eq. (4.10-2), dimensionless

Y fraction of unaccomplished change in Table 5.3-1 or Eq. (4.9-3)
Y expansion correction factor defined in Eqs. (3.2-9) and (3.2-11)

z distance in z direction, m (ft); also tower height, m (ft)
z temperature range for 10:1 change in DT, °C (°F)

Z height, m (ft); also temperature ratio in Eq. (4.9-2)
Greek letters
α correction factor = 1.0, turbulent flow and  , laminar flow

α absorptivity, dimensionless; also flux ratio = 1 + NB/NA

α thermal diffusivity = k/ρc , m2 /s (ft2 /h, cm2 /s)


p

α, αAB relative volatility of A with respect to B, dimensionless

α specific cake resistance, m/kg (ft/lbm)
α angle, rad
α kinetic-energy velocity correction factor, dimensionless

α* ideal separation factor =  / , dimensionless

αG gas absorptivity, dimensionless

αT eddy thermal diffusivity, m2 /s (ft2 /h)

ß concentration polarization, ratio of salt concentration at membrane surface
to the salt concentration in bulk feed stream, dimensionless
ß momentum velocity correction factor, dimensionless

ß volumetric coefficient of expansion, 1/K (1/°R)

ß ratio D2 /D1  of diameters, dimensionless

γ viscosity coefficient, N · sn'/m2  (lb /ft · s2−n')


m

γ ratio of heat capacities = cp /cν, dimensionless

Γ flow rate, kg/s · m (lbm/h · ft)

Γ concentration of property, amount of property/m3

δ molecular diffusivity, m2 /s

δ boundary-layer thickness, m (ft); also distance, m (ft)

δ constant in Eq. (4.12-2), dimensionless
δƒ film thickness for film theory, m (ft)

Δ difference; also difference operating-point flow rate, kg/h(lbm/h)

ΔL growth of crystals, mm

ΔTa arithmetic temperature drop, K, °C(°F)

ΔT1m log mean temperature driving force, K, °C(°F)

ΔH enthalpy change, J/kg, kJ/kg, kJ/kg mol(btu/lbm, btu/lb mol)

∇ design criterion for sterilization, dimensionless

Δp pressure drop, N/m2 , Pa (lb /ft2 )


f

ε roughness parameter, m (ft); or void fraction, dimensionless
ε emissivity, dimensionless; also volume fraction, dimensionless

εM mass eddy diffusivity m2 /s (ft2 /h, cm2 /s)

ε heat-exchanger effectiveness, dimensionless
ε void fraction of packing, dimensionless
εG gas emissivity, dimensionless

εt momentum eddy diffusivity, m2 /s (ft2 /s)

εmf void fraction at minimum fluidization, dimensionless

ηƒ fin efficiency, dimensionless

ηt turbulent eddy viscosity, Pa · s, kg/m · s (lbm/ft · s)

η efficiency, dimensionless

θ angle, rad
θ parameter in Eq. (11.7-19)
θ cut or fraction of feed permeated, dimensionless
θ* fraction permeated up to a value of x = 1 − L/Lf, dimensionless

λ wavelength, m (ft)
λ latent heat, J/kg, kJ/kg (btu/lbm); also mean free path, m (ft)

λ+ limiting ionic conductance in water of cation, (A/cm2 )(V/cm) (g equiv/cm2 )

λ− limiting ionic conductance in water of anion, (A/cm2 )(V/cm) (g equiv/cm2 )

λAb latent heat of A at normal boiling point, J/kg, kJ/kg mol (btu/lbm)

μ viscosity, Pa · s, kg/m · s, N · s/m2  (lb /ft · s, lb /ft · h, cp)


m m

μa apparent viscosity, Pa · s, kg/m · s (lbm/ft · s)

ν momentum diffusivity μ/ρ,m2 /s (ft2 /s, cm2 /s)

ν kinematic viscosity, centistokes
π1 dimensionless group, dimensionless

π osmotic pressure, Pa, N/m2  (lb /ft2 , atm)


f

ρ crystal density, g/mm3

ρ density, kg/m3  (lb /ft3 ); also reflectivity, dimensionless


m

σ interfacial tension of liquid, dyn/cm
σ constant, 5.676 × 10−8  W/m2  · K4  (0.1714 × 10−8  btu/h · ft2  · °R4 ); also
collision diameter, Å

Σ sigma value for centrifuge, m2  (ft2 )

τzx flux of x-directed momentum in z direction, (kg · m/s)/s · m2  or N/m2  (lb /ft2 ,


f
dyn/cm2 )

τ shear stress, N/m2  (lb /ft2 , dyn/cm2 )


f

τ holdup time, h

τ tortuosity, dimensionless
φ velocity potential, m2 /s (ft2 /h)

φ angle, rad; also association parameter, dimensionless

φ osmotic coefficient, dimensionless
φS shape factor of particle, dimensionless

Ψz flux of property, amount of property/s · m2

ψ correction factor, dimensionless

ψ stream function, m2 /s (ft2 /h)

ψp parameter defined by Eq. (14.3-13), dimensionless

ω angular velocity, rad/s

ω solid angle, sr
ΩD,AB collision integral, dimensionless
                             
                                                 
                                             
                                               
     

About the Author

C hr istie  John G e ankop lis is Professor of Chemical Engineering and Materials Science at the


University of Minnesota. He received his B.S. at the University of Minnesota and his M.S. and Ph.D. in
Chemical Engineering at the University of Pennsylvania. He has been teaching and doing research for
over 40 years.

His research interests are in mass transfer, biochemical engineering, and separation processes and he has
published extensively in these fields. Professor Geankoplis has also published a textbook entitled Mass
Transport Phenomena. He is the author of four editions of Transport Processes and Separation Process
Principles.

Professor Geankoplis was employed as a chemical engineer in the process industry for several years. He
has served as a consultant for many years for General Mills Chemicals, Inc. He has consulted with many
varied industries in the areas of ore extraction, biochemical processes, nuclear reactors, distillation,
extraction, absorption, adhesives, fermentation, mass transfer, and emulsions.

He is a member of the American Chemical Society and the American Institute of Chemical Engineers. He
also is a Licensed Professional Engineer in Ohio and Pennsylvania. His interests are travel, reading
ancient and medieval history, and playing tennis.