Design PM Interaction Curve For Circular Column
Design PM Interaction Curve For Circular Column
input
D or h = 1800 mm check
clear cover = 75 mm
effective cover, d' = 111 mm
d= 1689 mm
2
Ag = 2544690 mm gross area
2
Ac = 2240522 mm core area
Concrete M35
2
fck = 35 N/mm
a= 0.67
gm = 1.5
2
fcd = 15.63 N/mm
Steel Fe 500
gs = 1.15
fyd = 435 N/mm2
Es = 200 GPa
ey = fyd/Es = 0.00217
euk = 0.05 for uniform elongation as per Table 18.1 of IRC 112 and IS 1786
As per IRC 112 zoning of permissible strains, following salient points are identified on the strain block for the
calculation of (Pud, Mud):
+ --> compressive - --> tensile
strain at x = 0 d h xu/d
1. Tensile with no ecc. -0.05 -0.05 #DIV/0! = -ve inf
2. Dividing zone 1 & 2: 0 -0.05 0
3. Dividing zone 2 & 3: 0.0035 -0.05 0.065
4. Dividing zone 3 & 4: 0.0035 -0.00217 0.617
5. Dividing zone 4 & 5: 0.0035 0.00022 0 1
6. Compressive with no ecc 0.0020 0.0020 #DIV/0! = +ve inf
70000.0
60000.0
50000.0
40000.0
30000.0
Pud (kN)
20000.0
10000.0
0.0
0.0 2000.0 4000.0 6000.0 8000.0 10000.0 12000.0 14000.0 16000.0 18000.0
-10000.0
-20000.0
-30000.0
Mud (kN-m)
Check position of this point on above curve to see safe or not.