Mipi M-Phy PWM Data Rate

The document discusses the different configurations of M-PHY modules for Type-I and Type-II M-PORTS. For Type-I in LS mode, it supports PWM-G1 to G7 gears by default with fixed-ratio signaling. PWM-G0 is optional for Type-I with fixed-minor signaling. It provides the minimum and maximum data rates supported for each PWM gear.

Uploaded by

Taeho James Kim
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
496 views

Mipi M-Phy PWM Data Rate

The document discusses the different configurations of M-PHY modules for Type-I and Type-II M-PORTS. For Type-I in LS mode, it supports PWM-G1 to G7 gears by default with fixed-ratio signaling. PWM-G0 is optional for Type-I with fixed-minor signaling. It provides the minimum and maximum data rates supported for each PWM gear.

Uploaded by

Taeho James Kim
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

MIPI M-PHY Transceiver overview

§ M-PHY module
– Type-I vs. Type-II 구성 비교
§ LS mode의 구성만 다름.(PWM vs. NRZ signaling)

Fig. 5 Functional options for MODULEs in TYPE-I and Type-II M-PORTs

System IC Design Lab.@INHA univ 1


MIPI M-PHY Transceiver overview
§ M-PHY Type-I LS-mode
– PWM-G1~7 Gears 지원(Default PWM-G1)
§ Fixed-Ratio signaling
– PWM-G0는 type-I optional(independently)
§ Fixed-Minor signaling

Table 9. PWM-BURST GEARs


PWM-GEARs Min.(Mb/s) Max.(Mb/s)
PWM-G0 0.01 3
PWM-G1(default) 3 9
PWM-G2 6 18
PWM-G3 12 36
PWM-G4 24 72
PWM-G5 48 144
PWM-G6 96 288
PWM-G7 192 576
System IC Design Lab.@INHA univ 2