0% found this document useful (0 votes)
167 views29 pages

Z-18-PRO SON Matlab EN

The Z-18 Professional is a device that uses electromagnetic pulse methods to locate buried objects like metal, bricks, pipes, and voids in the ground up to several meters deep. It can detect magnetic irregularities and document buried findings without excavation. Proper use of the device requires reading the user manual and following instructions, as the effectiveness can be impacted by soil conditions. Hazards from unexploded ordnance are possible when excavating buried items, so care is needed.

Uploaded by

Özgür Karagöz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
167 views29 pages

Z-18-PRO SON Matlab EN

The Z-18 Professional is a device that uses electromagnetic pulse methods to locate buried objects like metal, bricks, pipes, and voids in the ground up to several meters deep. It can detect magnetic irregularities and document buried findings without excavation. Proper use of the device requires reading the user manual and following instructions, as the effectiveness can be impacted by soil conditions. Hazards from unexploded ordnance are possible when excavating buried items, so care is needed.

Uploaded by

Özgür Karagöz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 29

www.adrenalindedektor.

com

Z-18 Professional

Dear Customer,

Congratulations on choosing the Adrenaline Detector


product. The Z-18 Professional locates
magnetic irregularities in the target field. It is a product
that works with the electromagnetic pulse
method. This device can detect magnetically
loaded stones, bricks, metal burials, pipes,
warehouses, chests, etc., as well as void formations
such as soil layers, cavities, groundwater.

The Z-18 Professional can locate buried objects in different structures without excavation. It can document and
analyze them. Z-18 Professional has an easy and flexible use. Checking can be done quickly and easily. By selling the
product, you cannot guarantee that a finding will be made during your research. Recognition of hidden objects
depends on many factors. The main determining factors are proportional to the ground conductivity coefficient, the
mineral level and the depth of the object. Especially in very wet soil structure, clay and sand, high conductivity soils,
the recorded results are highly likely to be wrong.

With this product, you have purchased a device that has been tested for standard use. Please read the user manual
thoroughly and practice about using and operating the Z-18 Professional.

Important notes

Before using the Z-18 Professional device, read these operating instructions completely! The operating instructions
contain information on how to use the device and inform about potential sources of danger.

The Z-18 is used for professional detection and analysis of buried objects and changes in the ground.

It can visually determine the variations of the floor structure. Please read the user manual and carefully! and follow
the instructions.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 1


www.adrenalindedektor.com

Adrenalin makes no guarantee for this document. This applies without limitation to marketing and implied
warranties of fitness for a particular purpose. Adrenalin does not assume any liability for errors in this manual or for
malfunction or consequential damage or loss associated with the delivery, use, or customer use of this device.

No guarantee is given for the information and criteria given in this document. Under no circumstances will Adrenalin
accept liability for loss of profits, interruption of business activities or other indirect damages caused by errors in
these documents.

General Notes

In Adrenalin Z-18 Professional, careful control should be made in order to obtain proper and error-free data. Use of
the device for purposes other than its intended use or failure to comply with safety precautions may cause serious
damage.

Potential Health Hazards

The device does not pose any health hazard if used carefully. According to scientific data, high frequency signals
cannot harm the human body at low power.

Surrounding Area

A device that is brought from a cold area to a warmer area may not work for a while. Any moisture concentration
that may have built up can damage the device. Avoid the high magnetic fields created by vehicles, cell phones, base
stations and the use of detectors within 50 meters of the area to be measured.

Metal objects on the ground surface will adversely affect your measurement. The ground to be measured must be
cleared of metal objects. The user should remove all magnetic and metallic objects such as phones, chains and rings.

Voltage

Use the charger included in the scope of delivery, and a non-original charger may seriously damage the device.

Elements that can damage the device:

The interior of the device coming into contact with water.

Failure to clean the device due to heavy exposure to dust.

Impacts that will damage the cosmetics of the device.

Contact or exposure to high temperature.

Never contact with water to clean the device, a clean, dry and soft cloth will do the trick. Always store the device in
its protection case.

Make sure that all batteries and accumulators are always fully charged while operating in the system. Always charge
batteries fully discharged to prolong the life of batteries. Never charge batteries intermittently while they are full.

Important Note: Use original chargers to charge external and internal batteries.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 2


www.adrenalindedektor.com

Hazards That May Occur During Excavation

First of all, after detecting any underground object with this device, the location of the object should not be
excavated uncontrollably, and any dangerous situation should never be ignored. Our world has seen 2 world wars
and the remnants of these wars are still underground. These remains are unfortunately ammunition waste. These
wastes can cause various explosions during excavation, so you have to be aware of what the material you are facing
is. In addition, we should not hurry during the excavation, be careful and slow, we do not want to damage any
historical artifacts.

Be careful where you come across or remove such material, and never even take it home. Rocket launcher bullets,
Mortar bullets and various explosive objects etc. it can rust over time and cannot be understood due to deformities.
Therefore, attention should be paid to materials extracted from rust-looking soils called red soil. Explosives in such
areas become like powdered sugar over time, and if you encounter such a scene, you should be very careful because
these crystallized explosive dusts are extremely dangerous and the risk of explosion is very high at the slightest
friction. In such places, it is necessary to mark the region and inform the necessary units.

System requirements

The following indicators are the minimum requirements for Analyzer 3D software to run properly on the computer.

Interface (Data transmission) ............................................. ............................. USB, RS232

Free disk space ............................................... ....................................... 1Gb

Working memory (RAM) ............................................. ......................... 1Gb

Graphics card ................................................ .......................................... 64 MB, OpenGL compatible

OS ................................................ ...................................... Windows 7 – 10

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 3


www.adrenalindedektor.com

Installing Adrenaline Software

● ● Agree to start the Adrenalin_3D application provided with the device.

● ● 2. Click next to start the setup.

● ● 3. To start the installation, mark the Yes button and press the Next button.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 4


www.adrenalindedektor.com

● ● Step 4 Press the Finish button. Congratulations you have successfully completed the installation.

Bluetooth Pairing Device - Computer Comport

● ●1. In the start menu of the computer, type (bluetooth) in the search section. Usually (add bluetooth device) will
appear.

● ●2. On the page that opens, click on the device search section. Meanwhile, the device to be paired must be turned
on. A device named HC-06 must be detected. If the device is not found, restart the device and the computer and
repeat the process.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 5


www.adrenalindedektor.com

● ●3. Click on the found device (HC-06). In the window that opens, select the Enter match code section, enter the
connection code (1234) and complete the process.

● ●4. Learning the Bluetooth comport connection number

From the computer start menu, log into the device manager section. Click on COM and LPT and login. The number on
the upper part of the opened section is the comport connection number. (Example 3)

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 6


www.adrenalindedektor.com

● ● Using the Device

● ● Step 1 Double-click the icon on the desktop to start the Adrenalin 3D program.

● ● Step 2 To continue, allow 2 security checks that come in order and press the "Yes" button.

● ● Step 3 The program will take approximately 40 seconds to open.

● ● 4. After the program is opened, enter the activation code given next to the device in the Serial Number section in
the window that opens and press the Active button. If you encounter a problem, contact our company.

Note: The activation code is only compatible with the computer that came with the device. To install on another
computer, a new activation code must be requested.

● ● 5. In the example we have given in the "COM Port" connection section, COM 3 is selected. Whichever comport is
set on the coming device, that option should be used. (Connect) button should be pressed. The connection is
established when the blue Bluetooth connection LED on the device starts to light continuously.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 7


www.adrenalindedektor.com

Note: An error message will appear when the wrong comport number is selected and the connection is attempted.
To solve the problem, the connection must be established by pressing the (Disconnect) button once, selecting the
correct comport number and pressing the (Connect) button again.

● ● Step 6 When the program is opened, click the New button under the text File on the upper left to make a new
scan.

● ● Step 7 You need to make important adjustments in the window that appears, first of all, (Regular Scan) is
selected for ground analysis.

The number of samples to be made is selected from the (Blow) section, in the example (10). In order to get healthy
results, shots should be made with at least (20) signals.

The alignment method to be used for taking samples is selected from the (Direction) section.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 8


www.adrenalindedektor.com

● ● Bluetooth Data Transfer

Bluetooth data transfer Z-18 Immediately after the professional Bluetooth connection process is made, the method
to be searched from the electronic device is selected and the screening is performed simultaneously with the
scanning.

You will get a snapshot of each row after the first scan sequence is finished. The first row is used for soil calibration
and the second row should be scanned by passing a right and the image will be taken.

● ● Scope of Delivery

1. Control unit

2. Notebook - 3D software

3.Transporting bag

4.1 meter super sensor - 50 cm horizontal sensor

5. Headset

6. Charger

7.Sensor carrying case

8.User manual

9. Warranty card

● ● Modes of Operation

1- Single Mode Image Transfer

2- Detector Always Mode Metal Discrimination - Live shot

3- Auto Mode Single Sample Image Transfer (10-20-30-40-50)

4- Settings

5- Test Mode

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 9


www.adrenalindedektor.com

● ● Single Mode Image Transfer

With the Z-18 Professional Underground Imaging System, the start button must be pressed at each step to take an
image sample in this mode. The image of each sample taken is instantly displayed on the computer screen. It is
recommended to use this mode in order to obtain a homogeneous view especially on rough terrain.

This mode is entered by pressing the (START) key like other menus. In order to take manual sampling while shooting,
it is necessary to press the (START) button again each time a signal is desired. The number of samples taken can be
monitored instantly on the device screen. If the number of shooting signals is desired to be done, the signal
reception process can be continued by switching to the side row when the sampling signal is received. The advantage
of this mode is that it provides comfortable and effortless shooting without any time limitation on rough terrain.

● ● 2-) Detector Always Mode Metal Discrimination - Live shot

It is used with two different methods, with and without a computer connection.

When used in connection with a computer, it is used by selecting the (Live Scan) menu. It is used to detect metal and
space with the help of continuously progressing spectrum. The ascending spectrum is considered to be the (+)
anomaly change. The descending spectrumis considered as an (-) anomaly change.

The signal values taken during the measurement on the computer screen are expressed in various colors. The user
can detect metal and space with continuously advancing colors on the computer screen. Red hues are considered as
(+) anomaly variation. Blue hues are considered as (-) anomaly variation.

This mode can also be used without a computer connection. The device can report detected magnetic differences by
showing numerical values on the audio and digital display. When desired, sound differences such as a metal detector
are monitored and used for detecting metals and structures containing spaces.

During the measurement, the underground imaging system notifies the user of the detected objects on the digital
display of the device with numerical numbers. (-) numbers indicate space structures, (+) numbers indicate that
metals are detected. Z-18 Professional also announces detected objects through internal speakers or headphones.
Thin tone of voice indicates that metals, deep tone of voice, void structures are detected.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 10


www.adrenalindedektor.com

● ● 3-) Auto Mode Single Sample Image Transfer (10-20-30-40-50)

Z-18 Professional underground imaging radar data obtained during automatic measurement are instantly displayed
in 3D in the computer program. The data received with this mode are used for detailed analysis. Before the search
starts, the number of progress steps is entered into the computer program and the electronic device.

The device gives an audible warning for every sample it receives. The user steps forward synchronously with this
warning sound. When the measurement sequence is finished, the device will stop automatically and the user will be
informed audibly that the scan in that direction is finished. This process continues sequentially until the scanning
area is over. In this shooting mode, data is transferred to the computer live.

During the measurement, the underground imaging system notifies the user of the detected objects on the digital
display of the device with numerical numbers. (-) numbers indicate space structures, (+) numbers indicate that
metals are detected. Z-18 Professional also announces detected objects through internal speakers or headphones.
Thin tone of voice indicates that metals, deep tone of voice, void structures are detected.

It is selected in the computer program (Regular Scan). It is used for real time instant 3D image acquisition at the
same time in real time in regular scanning process. The first row of shots is used for soil calibration. No images can be
taken. (2.) Sequence shooting (1.) It is performed by moving one step to the right of the row. Small measurement
value corrections required by the computer program are automatically made during the scanning process.

3. The next autosampling reception mode is selected. When the (START) button on the device is pressed, the
(calibration) process takes place first.

Note: With the calibration process ready to search, the user's direction must be facing south at the starting point
where the first signal will be received. The sensor should be built 10 cm above the ground.

After the calibration process, the device goes into standby ready to send automatic data data. The number of signals
to be received in the forward direction is selected from the menu of the device. Values between 10 signals and 50
signals can be selected. At the end of how many signals are selected, the device will give a warning sound and will
end the shooting and go into standby. If we assume that we have selected 10 signals, the order will be as in the
example.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 11


www.adrenalindedektor.com

When 10 shots are taken automatically in sequence, the device beeps and ends the shot.

At the end of this beep, the first ten sampling signals are received. The (START) key is used to start the second
automatic 10 sampling. The (START) key is used to start all measurement samples.

(START) button is used for entering the menus. To enter the menus, it is sufficient to press the (START) button
shortly. To exit the menu, it is necessary to press the (OK) button. You will hear a sound exit from the menu.

In all shooting modes, the first row of shots is used for soil calibration.

● ● 4-) Settings

(START) button is used to enter the settings menu.


-AUTO BLOW
Press (START) button once to enter.
Auto blow operation determines how many (step) signals will be in forward direction in automatic shooting.
(10-20-30-40-50) The device will stop automatically when it reaches the selected number of signals. The
number of signals selected from auto blow must also be selected from the computer.
-AUTO DELAY
Press (START) button once to enter.
Auto delay is the time setting between signals. In automatic shooting, you set the pace yourself.
-DETECTOR DELAY
Press (START) button once to enter.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 12


www.adrenalindedektor.com

Detector delay process determines how many (step) signals will be in forward direction in manual shooting.
(10-20-30-40-50) The number of signals can be selected according to image transmission. The number of
signals selected in Detector delay must also be selected from the computer.
-SOUND
Press (START) button once to enter.
The volume of the device is adjusted. It serves to turn on and off the sound given to the speaker.
-RESET

Press (START) button once to enter.


Returns the settings made in the device to factory settings.

● ● 5-) TEST MODE

Press (START) button once to enter.


It is used to test whether the sensors in the device work or not. Sensor # 1 is above.
Sensor number 2 is below. You can test whether it works or not by passing 1 magnet near the sensor.

● ● Metal Discrimination Menu

Ferromagnetic metals (Containing Ferrous)

Ferromagnetic targets have a positive signature. It shows the typical signature of a ferromagnetic metal such as iron.
The signature frequency curve contains positive.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 13


www.adrenalindedektor.com

Non ferromagnetic metals (Non-ferrous)

It shows the typical signature of a non ferromagnetic metal. The signature frequency curve includes a positive (red)
and a negative amplitude. The first signature starts with a positive amplitude and the second signature starts with a
negative amplitude. The order is not important. It depends on the movement direction of the super sensor. If you
keep moving the search bar from side to side, these 2 signatures will change constantly.

Be careful to move the Super sensor slowly and evenly over the ground and over a target to get a clear signature.

Super Sensor Separation

The super sensor should be held upright and facing the ground. It should not be turned or turned around its own
axis.

Normally this operating mode is used when a complete measurement is carried out in the "Ground Scan" operating
mode. It is mainly used for detailed analysis of the detected object.

Thanks to the analysis of the results of your measurements in the "Ground Scan" mode, you can determine the
position of an existing object and now, thanks to the Super sensor, you can know where you need to do detailed
research inside the measurement area. In this operating mode, the entire measured area will be sent directly to a
computer. Therefore, first of all, adjustment of data transfer should be done in 3D software.

All non-metallic materials have a pure negative signature.

This is a typical signature for all non-metallic targets and structures. These can be voids, tunnels or buried plastic
pipes or boxes. You may notice that there is only negative (blue) amplitude.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 14


www.adrenalindedektor.com

● ● General Scan

Generally, every measurement always starts in the lower left corner of your scan area. Applies to parallel shooting. In
zigzag shooting mode, the image will start from the top left corner. Starting from this point, you should walk one
scan path and then another scan path, each following scan path should be to the left of the previous one. As you
walk along these lines, the measurement values will be recorded and directly transferred to a computer, depending
on the selected operating mode.

In automatic shots, the device stops at each scan path completed, so the user can find the starting point of the next
path. In this way, all paths are recorded and the area is measured.

You can also determine the optimal starting point for your measurement, depending on the composition of the soil.

Scan paths can be described as "Zigzag" or "Parallel" layers. In addition, the number of strokes (measuring points)
recorded during a scan path can be individually adjusted, depending on the size of your scan area (scan path length).

● ● Scan Mode - Scan Paths

There are two general techniques for surveying an area with the Z-18 Professional:

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 15


www.adrenalindedektor.com

Zigzag

The starting position of the two adjacent scan paths is on the opposite side of the measured area. You save data on
the scan path and on the return path. There is no image transfer during the first start, the program uses the first row
for soil calibration. The start signal of the image is in the upper left.

● ● Parallel

The starting position of the two scan paths is always on the same side of the measured area. You save data in only
one path and one direction, and you simply walk back to the starting point without logging data on the next scan
path. There is no image transfer during the first start, the program uses the first row for soil calibration. The start
signal of the image is at the bottom left.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 16


www.adrenalindedektor.com

● ● Paralel mi Zigzag mı?

Parallel or Zigzag?

Both scanning modes are suitable for experienced Z-18 Professional users.

Considering the experience, the best graphics are obtained in "Parallel" mode. Because the same sweep direction is
always used and walking speed can be optimally coordinated. The parallel mode is preferred especially in areas that
are not flat, such as mountain slopes, slopes or other slopes.● ● Sensör Yönlenimi

The distance of the search rod to the ground must always remain the same during a measurement. We generally
recommend a distance of 10 cm from the floor surface.

If there are obstacles such as rocks, woods or tall grass in your sweep area, you should start measuring from the very
beginning by increasing the distance between the search bar and the ground. In such cases, you can search at a
height of 50 cm from the ground, for example. The important thing is that you keep this distance throughout the
measurement. In any case, you should avoid scrolling the search bar up or down!

Another important consideration is the physical orientation of the search bar.

The orientation of the search bar does not change during the "parallel" scan mode because it is always measured in
the same direction.

In "Zigzag" scanning mode, the orientation of the search bar turns 180 ° at the end of each scanning path, if you
change your position with the device to walk back and forth and continue scanning, this change in orientation may
negatively affect the scan result.

Even though the Z-18 Professional uses an integrated automatic reversing electronics setup, the resulting graphic
may contain red and blue stripes. In this case you should repeat the measurement in either the "Parallel" or "Zigzag"
scan mode and avoid turning at the end of each scan path and walk back instead.

● ● Where Should Automatic Mode / Manual Mode Be Preferred?

Large flat surfaces can be measured in automatic mode. The manual strike mode is mostly used on difficult grounds
or when the measurement result needs to be much more realistic.

It is wise to use the manual shooting mode in hard-to-reach places such as rocky mountain slopes, slippery surfaces
or areas with excessive vegetation. Since each hit will be sent manually, you have enough time to position the search
bar correctly and save the measured value. This way you can also accurately measure the previously marked points
of a predefined graph grid

.● ● Special Recommendations for Field Procedure

There are some points you should pay attention to during measurement. In principle, the resulting 3D graphic can
only be as good as the measurement you recorded. An incorrect measurement creates inaccurate graphs.

Before starting a measurement in the field, you need to consider what you are looking for and whether the selected
area is suitable. Taking measurements without any plans can give unacceptable results. Please consider the following
recommendations:

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 17


www.adrenalindedektor.com

What do you want to locate (grave, tunnel, buried objects)? This question has a direct impact on performing the
measurement. If you are looking for large objects, the distance between measurement points and scan paths can be
greater.

Inform yourself about the area where the area is located and what you are looking for. Does it make sense to search
there? Are there historical references that support your speculation? What kind of soil is there in this region? Are
there good conditions for data recording? Are searches allowed in this area (eg private property)?

● ● Live Scan

It is used for live scanning and instant simultaneous images. It acts like a metal detector. It is not necessary to move
in the (north-south) direction during scanning. But moving by following the (north - south) direction will always
provide you with better results on this device. It gives information about the objects detected by the color scale and
perception sounds moving continuously from top to bottom on the computer screen, which expresses the walking
direction. In live shooting modes, it is necessary to decide during live shooting about the size and depth of the
detected object with the help of color intensities and sound intensity.

As in other shooting modes, red color plus anomaly represents magnetic stones and metals, while blue color
represents loose ground and space structures in live shooting mode. We recommend using our models with
horizontal probe (8 - 16) sensors to get the highest performance in live shooting mode.

● ● Live Scan Menu

(50-100-150-200-250-300) Live shot detection sensitivity can be adjusted by selecting the number. Detects as (50
most sensitive) (300 weak sensitive). When a deep search is desired, (50) should be selected, the sensor is brought to
the ready-to-search position and the search is performed by resetting. When searching for superficial or very large
targets, (100) or higher values should be selected, the sensor is brought to the ready-to-search position and the
search is performed by resetting.

SET ORIGIN (RESET): It is used to reset the signal value to be displayed. The zero point is determined and the negative
(-) anomaly is colored blue and the positive (+) anomaly is colored red.

● ● Start shooting

Necessary settings should be made in the computer program and control unit to shoot live. The connection settings
given in the photo below should be applied.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 18


www.adrenalindedektor.com

Editing the Number of Hits Per Scan Path


Before you start measuring, you need to determine the number of strokes and scan paths.

The number of measuring points is determined. The number of measurements must be marked in the computer
program and device. If the measurement number is not specified, the device will automatically shoot 10 signals
and pause. You need to start the second 10 signal by pressing the start key

There is no specific rule for choosing the correct number of strokes. However, there are different factors to
consider. These are the length of the area to be measured and the size of the objects searched.

The preferred distance between two beat signals in measurements should be approximately (15 - 20) cm. The
smaller the distance between two strokes, the clearer and more integrated the graphic representation is. If you
are looking for small objects you need to choose short distances, for larger objects the distance between strokes
can be increased. In the large object search, two strokes can be distance between (30 cm).

When walking along the crawling paths, you should not only pay attention to the number of strokes, but also your
walking speed. Each scan path should be measured at the same speed as the previous scan paths. Applying
different walking speeds in the scan paths results in shifts in the scan path. Therefore, locations inside your scan
area may not be measured at all, and areas outside of the scan area and unintended areas may be included in the
scan. Unwanted errors may occur when the recorded data is combined into 3D images. Generally, the following
rule applies:

The slower and evener you walk along each scanning path while measuring, the smaller the distance between the
measuring points and the more realistic your scanning result will be!

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 19


www.adrenalindedektor.com

The picture shows the effect of distance and number of hits per scan path for searched objects.
It shows the difference between very few strokes (left side) and much more strokes (right side) on a scan path of the
same length. Therefore, the second record (right side) shows much more detail and also smaller objects can be seen.
Feel free to record more measurements with different beats. For example, you can scan a large area before making a
second detailed precision measurement. You can proceed this way, especially when searching for large objects. This
way you can measure a large area in a very short time and then save only the subsections that you are interested.

Correct walking speed Wrong walking speed

Special Recommendations for Field Procedure

There are some points to be considered during measurement. The resulting 3D graphic can only be as good as the
measurement you recorded. A wrong measurement and wrong shots create wrong graphics.

Before starting a measurement in the field, you need to consider what you are looking for and whether the selected
area is suitable. Taking measurements without any plans can give unacceptable results. Please consider the following
recommendations:

What do you want to locate (grave, cellar, metal, treasure)? This question has a direct impact on performing the
measurement. If you are looking for large objects, the distance between measurement points and scan paths can be
greater.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 20


www.adrenalindedektor.com

You must have information about the area where the search area is located and what you are looking for. Does it
make sense to search there? Are there historical references to support your search idea? What kind of soil
structure is there in this region? Are there good conditions for searching? Searching is allowed in this area.

The first measurement you make in an unknown area should include a large enough area to obtain a sufficiently
representative value and be large enough to have an idea of the entire area. Beyond that, every control must be
focused to be detailed.

What is the shape of the object you are looking for? If you are looking for a square metal box, the defined object on
your chart should have a shape that matches it.

To obtain exact values in terms of depth measurement, the object must be in the center of the graph, which means
that the object must be framed by normal reference values (normal ground). If the object is to the side of the graph
and is not fully visible, an accurate depth measurement is not possible, but also the size and shape measurement is
limited. In this case, repeat the measurement and change the position of your scan area to get the optimal position
of the anomaly in the graph.

There should be no more than one object in a chart. This affects the accuracy of the depth measurement. It is
useful to perform a partial area scan for such targets.

You should run at least two control scans to be sure of your results.

So you can also detect and isolate mineralization deposits.

3D Software Menu Functions

 FILE
 New: New Project: Click here to do a new scan and transfer the data to your PC. Before you start shooting,
you need to configure data data transmission.
 Open: It is used to study or re-analyze data stored on the computer.
 Save: It is used to save the new measured project in the computer memory..
 If you save a measurement data and later make changes in the graph again. You must save the chart data
again. Note: If you need to record again, create a new record with another name, image may be distorted,
the operation cannot be undone.
 Exit: Used to exit the program.

● ● Filter Modes (Edit)

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 21


www.adrenalindedektor.com

1-Smooth
2-Sharp
3-Edge Detection
4-Weak Detection
5-Reset

●Smooth (Ctrl+1)

It is a filter that eliminates weak signals.

● Sharp (Ctrl+2)

It is a filter that brings out weak signals that are shot.

● Edge Detection (Ctrl+3)

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 22


www.adrenalindedektor.com

It helps you to understand the objects close to the surface by showing the places where the change is high in the
shot image.

● Weak Detection (Ctrl+4)

It is used to amplify weak signals in the shot image.

● Reset (Ctrl+5)
It is used to restore the filter applied on the image.

● ● View

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 23


www.adrenalindedektor.com

● Graph
*Surface (Ctrl+6)
Unfiltered plain 3d image.

*Contour

It shows the transition layers between signals.

*Filled Contour

Displays numerical values by coloring the transition layers between signals.

● Color Map
*Rainbow

Color 3d image map.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 24


www.adrenalindedektor.com

*X-Ray

Black and white 3d image map.

● Interpolation
*Cubic (Ctrl)

It softens the signal amplitudes.


*Linear

It shows the signal transitions in their natural state (without smoothing).

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 25


www.adrenalindedektor.com

● ● About

Shows company and auxiliary information.


● ● Right mouse button

*Reset to orijinal wiew

Go back to the original view.


*Go to X-Y view

X and Y plane.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 26


www.adrenalindedektor.com

*Go to X-Z view

X and Z plane.
*Go to Y-Z view

Y and Z plane.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 27


www.adrenalindedektor.com

*Rotate Options

-Plot Box Rotate

Rotation for low system computers.


-Continuous Rotate

Rotation for normal system computers.


-Stretch-to-Fill Axes

It shows the 3d image according to the screen size. It does not preserve the aspect ratio.
-Fixed Aspect Ratio Axes.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 28


www.adrenalindedektor.com

It shows the screen image according to the real shot values. Maintains the aspect ratio.

ADRENALİN DEDEKTÖR

Muradiye mah. 97. Sokak İlk yurt sitesi E-blok No:23 Muratlı / TEKİRDAĞ

TEL: + 90 539 847 63 83 www.adrenalindedektor.com [email protected] Sayfa 29

You might also like