0% found this document useful (0 votes)
66 views2 pages

A01-Rev3-GB SB4 Data Sheet

The Type SB4 load cell is a stainless steel beam load cell with complete hermetic sealing, making it suitable for harsh industrial environments. It has a wide range of capacities from 5 kN to 100 kN and approvals for hazardous areas. Key features include stainless steel construction, IP68 environmental protection, and a unique blind loading hole. It is used in platform scales, hopper scales, and tank scales.

Uploaded by

Farit Ardiansyah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views2 pages

A01-Rev3-GB SB4 Data Sheet

The Type SB4 load cell is a stainless steel beam load cell with complete hermetic sealing, making it suitable for harsh industrial environments. It has a wide range of capacities from 5 kN to 100 kN and approvals for hazardous areas. Key features include stainless steel construction, IP68 environmental protection, and a unique blind loading hole. It is used in platform scales, hopper scales, and tank scales.

Uploaded by

Farit Ardiansyah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Type SB4 Load Cell

IP68
APPROVED

Product Description Approvals


The type SB4 is a stainless steel beam type load cell with complete hermetic  OIML approval to C1 (Y = 5�����������
 ����������
000), C3,
sealing. It is a perfect fit for use in harsh industrial environments. C3 MI7.5, C4 and C4 MI7.5 (Y = 11 000)
 NTEP approval to 5 000 intervals, Class III
Application (for 5 kN to 50 kN)
 Platform scales, hopper and tank scales  ATEX hazardous area approval for Zone
0, 1, 2, 20, 21 and 22
Key Features  FM hazardous area approval
 Wide range of capacities from 5 kN to 100 kN (510 kg to 10 197 kg)
 Stainless steel construction Packed Weight
 Environmental Protection IP68 with complete hermetic sealing  Capacity (kN) 5–20 50 100
 Unique blind loading hole Weight (kg) 1.4 2.9 7.1
 High input resistance
 Calibration in mV/V/Ω Available Accessories
 Compatible range of application hardware
Options  Compatible range of electronics
 OIML approval to C3 MI7.5
 OIML approval to C4 MI7.5 (for 5 ... 50 kN)

A01-Rev3-GB-1(2)
WWW.FLINTEC.COM
Specifications
Maximum capacity (Emax) kN 5 / 10 / 20 / 50 / 100 5 / 10 / 20 / 50
Metric equivalents (1 N=0.10197 kg) kg 510 / 1 020 / 2 039 / 5 099 / 10 197 510 / 1 020 / 2 039 / 5 099
Accuracy class according to OIML R60 (GP) C1 C3 C3 MI 7.5 C4 C4 MI 7.5
Maximum number of verification intervals (nmax) n.a. 1 000 3 000 4 000
Minimum load cell verification interval (vmin) n.a. Emax /5 000 Emax /11 000
Temperature effect on minimum dead load output (TC0) %*RO/°10C ≤ ± 0.0400 ≤ ± 0.0275 ≤ ± 0.0127
Temperature effect on sensitivity (TCRO) %*RO/°10C ≤ ± 0.0200 ≤ ± 0.0160 ≤ ± 0.0100 ≤ ± 0.0080
Combined error %*RO ≤ ± 0.0500 ≤ ± 0.0300 ≤ ± 0.0200 ≤ ± 0.0180 ≤ ± 0.0180 ≤ ± 0.0150
Non-linearity %*RO ≤ ± 0.0400 ≤ ± 0.0300 ≤ ± 0.0166 ≤ ± 0.0166 ≤ ± 0.0125 ≤ ± 0.0125
Hysteresis %*RO ≤ ± 0.0400 ≤ ± 0.0300 ≤ ± 0.0166 ≤ ± 0.0066 ≤ ± 0.0125 ≤ ± 0.0066
Creep error (30 minutes) / DR %*RO ≤ ± 0.0600 ≤ ± 0.0490 ≤ ± 0.0166 ≤ ± 0.0066 ≤ ± 0.0125 ≤ ± 0.0066
Rated Output (RO) mV/V 2 ± 0.1%
Calibration in mV/V/Ω (A...I classified) % ≤ ± 0.05 (≤ ± 0.005)
Excitation voltage V 5...15
Zero balance %*RO ≤±5
Input resistance (RLC) Ω 1 100 ± 50
Output resistance (Rout) Ω 1 000 ± 2
Insulation resistance (100 V DC) MΩ ≥ 5 000
Safe load limit (Elim) %*Emax 200
Ultimate load %*Emax 300
Safe side load %*Emax 100
Compensated temperature range °C –10...+40
Operating temperature range °C –40...+80 (ATEX –40...+60)
Load cell material stainless steel 17-4 PH (1.4548)
Sealing complete hermetic sealing; cable entry sealed by glass to metal header
Protection according EN 60 529 IP68 (up to 2 m water depth) / IP69K

The limits for Non-Linearity, Hysteresis, and TCRO are typical values.
The sum of Non-linearity, Hysteresis and TCRO meets the requirements according to OIML R60 with pLC=0.7.

Dimensions (in mm)

L1 41
L2 L3 L4 ØD1
30 H4 H5
A Ø4

H1
H3
H2
A
ØD2 (2x) W
A-A
L5

Type L1 L2 L3 L4 L5 H1 H2 H3 H4 H5 W D1 D2 Mounting bolts Torque*


SB4-5/10/20 kN 155 15 80 35 76 36 6 21 7 4 30 18 13 M12 8.8 90 Nm
SB4-50 kN 190 21 105 40 93 49 8 28.5 6 8 43 25 21 M20 8.8 400 Nm
SB4-100 kN 245 30 135 50 120 73 12.5 42 10 n.a. 60 30 27 M24 8.8 700 Nm

* Torque values assume oiled threads.

Wiring
 The load cell is provided with a shielded, 4 conductor cable (AWG 24).
+ Excitation (green)
Cable jacket polyurethane
 Cable length: 3 m for SB4-5 kN/10 kN/20 kN
+ Signal (white)
4.5 m for SB4-50 kN/100 kN
 Cable diameter: 5 mm
 The shield is floating – Excitation (black)
(On request the shield can be connected to the load cell body) – Signal (red)
Shield (yellow)

A01-Rev3-GB-2(2) Specifications and dimensions are subject to change without notice.


WWW.FLINTEC.COM