Advanced Design of RCC Structures

This document provides design problems for an advanced reinforced concrete structures course. It includes 8 potential design problems covering various reinforced concrete elements: 1. Design of an intermediate portal frame for a two bay reinforced concrete structure. 2. Design of a circular slab and explanation of grid floor slab types and reinforcement details. 3. Design of a foot bridge with given parameters and reinforcement sketch. 4. Design of a T-beam bridge with given parameters and reinforcement sketches. 5. Determination of seismic forces for an 8 story building with given parameters. 6. Explanation of factors affecting structural response and design of a reinforced concrete bunker. 7. Design of a intake tank including top

Uploaded by

Rajiv bhatia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
407 views2 pages

Advanced Design of RCC Structures

This document provides design problems for an advanced reinforced concrete structures course. It includes 8 potential design problems covering various reinforced concrete elements: 1. Design of an intermediate portal frame for a two bay reinforced concrete structure. 2. Design of a circular slab and explanation of grid floor slab types and reinforcement details. 3. Design of a foot bridge with given parameters and reinforcement sketch. 4. Design of a T-beam bridge with given parameters and reinforcement sketches. 5. Determination of seismic forces for an 8 story building with given parameters. 6. Explanation of factors affecting structural response and design of a reinforced concrete bunker. 7. Design of a intake tank including top

Uploaded by

Rajiv bhatia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

B.E.

Eighth Semester (Civil Engincering) (CGS)


10240 : Professional Elective-Il: Advanced Design ofRCC Structures
8CE04
P. Pages : 2 AW - 3144
Timc : Four Hours fliffrlfiIfllill Max. Marks : 80

Notes : I All question carry equal marks.


2 Answer two question fom Section A and two question fiom Section B
3 Due qedit will be given to ncatsress altd adequate dimensioDs.
4 Assume suitable data whetever necessary,
5 Illustiate your arswer necessary with the help of neat sketches.
6 IS 456 : 2000,IS 875, tS 1893 : 2002,IS 3370 m&y be consulted.
7 Use ofpen Blue/Black ink/refill only for writing the answer book.

SECTION _ A

1. A teinforced concrete two bay portal frane is used for covering a hatl 20 m wide by 40 m 20
length. Distance between centre line of column is 10.0 m. The portals are spaced at 4 m
intervals. The height of column is 5 m. Provide thickness of stab 120 mm. Design one of
the intermediate portal ftame.
Assume fixed condition at the base ofthe column. Assume SBC ofsoil 250 kN / m2 . Sketch
the details ofreiDlorcement in the pottal fiamc.
OR
2. a)
Design a circular slab of 6.5 m lntgmal diametcr to support live load of 4kN/m2'
14

Use M 20 concrete and Fe 415 steel. Assume any other data if required. Sketch lhe
reinforcement details oftop C/S plan & bottom c/s plan & typical C/S

b) Explain the following terms :


6

D Types ofgid floor slab

ii) Typicol reinfolcement details

3 Design a foot b dge for the following data 20

i) Clear roadway uidth = 3.0 m.

ii) Effective span = l0 m

iii) Live load: 5kN/m2

iv) Wearing coat thickness at centlc 100 mm & at fte end 80 mm

v) Use M 20 grade concrete & Fe 415 steel.


vi) Sketch lhe rcinforcement details.
OR

AW-3144 1
P.T.O
4. Design a T - Beam bridge for following data. 20

i) Effectire span = 15 m.
ii) Width ofcarriage rvay = 6.5 m
iii) Thickness of wearilg coal: 100 mnl
i\') IRC class-A Loading
v) Material M - 25 - F'e 415
Sketch the details of reinforcement in l,/S and C/S ofslab and beam.

SECTIO}' - B
5 A eight stoicy SMRI' building has plan dimensions as shown in fig. 5. The storey height is 20
3.2 m. The dead load per unit area of the floor, consisting of lloor slab. finishes ctc is
4kN /m2. The outcr wall is of 230 mm an<l inner partition wall is of 175 mm including
plastcr.-fhe intensity of Livc load on each lloor is 3kN/m2 and on roof is t.5kN/m2.
Building is located is Zonc Il[ and soil below foundaiion is hard. Detemine Seisnric forces
and shear at different floor Ievels.

5m

5m

5m

II
.ffit
)m )m im Jm 5m
5m

liig. No. 5

OR
6. a) Explsio factors affecting to structural response. 5

b) A bunker is to be designed to store 500 kN ofcoal having unit weight of 9kN/m3. t5


"oul
The bunker should be square with 3.5 m sides.'l-he storcd coal is to be sucharged to an
angle ofresponse Joo. Using M 20 concrele aod -F'e 4l 5. Sketch thc details ofReinforcemcnt.

Work out the dimensions of Intzc tar* for capacity of I million litres. Design top dome, 20
ring beam (Top), Cylindrical wall & ring beam (Uottom). Use M 20.grade ofconcr€te and
Fe 415 steel. Draw the sketches giving structuml dctails.

OR
8. Design raff fotmdation for lntze tank of capacit"v of l5 lack litres. The tank is supported on 20
eight ctcular column. The total load on ring girder below bottom spherical domc is 18,000
kN. Wind Load intensity is I .5 kN / m2 . Height of sraging above grourd level is l6 m. Safe
bearing capacity ofsoil is 250 kN / m2 . Use M 25 grade ofconcrcte & Fe 4l 5 stecl. Assume
any other data if requircd. Skelch thc reinforcement details.