0% found this document useful (0 votes)
70 views

Victaulic Reducing Coupling Style 750: 1.0 Product Description

The document provides product details for Victaulic reducing couplings including available sizes, materials, maximum working pressures, dimensions, and certifications. It contains information on the housing, gaskets, bolts, nuts, and other specifications for the couplings.

Uploaded by

jagger7scrib
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
70 views

Victaulic Reducing Coupling Style 750: 1.0 Product Description

The document provides product details for Victaulic reducing couplings including available sizes, materials, maximum working pressures, dimensions, and certifications. It contains information on the housing, gaskets, bolts, nuts, and other specifications for the couplings.

Uploaded by

jagger7scrib
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Victaulic® Reducing Coupling

Style 750 06.08

1.0 PRODUCT DESCRIPTION


Available Sizes
• 2 x 1" through 10 x 8"/DN50 x DN25 through DN250 x DN200
Pipe Material
• Carbon steel
• For exceptions reference section 6.0 Notifications
NOTE
• For other pipe materials, contact Victaulic.

Maximum Working Pressure


• 500 psi/3447 kPa
• Working pressure dependent on material, wall thickness and size of pipe
Application
• Joins Original Groove System (OGS) roll grooved and cut grooved pipe, as well as OGS grooved fittings, valves and
accessories
• Permits direct reduction on piping run
• Optional steel washer prevents telescoping of the smaller pipe inside the larger pipe during vertical system assembly
Pipe Preparation
• Cut or roll grooved in accordance with publication 25.01: Victaulic Standard Groove Specifications.

2.0 CERTIFICATION/LISTINGS

NOTE
• Download publication 10.01 for Fire Protection Certifications/Listings Reference Guide.

ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT.

System No. Location Spec Section Paragraph

Submitted By Date Approved Date

victaulic.com
06.08 1536 Rev M Updated 05/2020 © 2020 Victaulic Company. All rights reserved.
1
victaulic.com

3.0 SPECIFICATIONS – MATERIAL


Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395,
Grade 65-45-15, is available upon special request.
Housing Coating: (specify choice)
Standard: Orange enamel.
Optional: Hot dipped galvanized conforming to ASTM A153.
Optional: Contact Victaulic with your requirements.
Gasket: (specify choice1)
Grade “E” EPDM
EPDM (Green stripe color code). Temperature range –30ºF to +230ºF/–34ºC to +110ºC. May be specified for hot
water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical
services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot +180°F/+82°C potable
water service and ANSI/NSF 372. NOT COMPATIBLE FOR USE WITH PETROLEUM SERVICES OR STEAM
SERVICES.
Grade “T” Nitrile
Nitrile (Orange stripe color code). Temperature range –20ºF to +180ºF/–29ºC to +82ºC. May be specified for oil
related services, including air with oil vapor, this gasket may be specified for temperatures rated up to
+180°F/+82°C. For water related services, this gasket may be specified for temperatures rated up to
+150°F/+66°C. For oil free, dry air services, this gasket may be specified for temperatures rated up to
+140°F/+60°C. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES.
Others
For alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide.
1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should
always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible.

Bolts/Nuts (specify choice2):


Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial)
and ISO 898-1 Class 9.8 (M10-M16) Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the
mechanical property requirements of ASTM A563 Grade B (imperial – heavy hex nuts) and ASTM A563M Class
9 (metric – hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FE5, finish Type III
(imperial) or Type II (metric).
Optional: Stainless steel oval neck track bolts meeting the mechanical property requirements of ASTM F593,
Group 2 (316 stainless steel), condition CW. Stainless steel heavy nuts meeting the mechanical property
requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling reducing coating.
Assembly Washer (optional): Galvanized carbon steel.
2 Optional bolts/nuts are available in imperial size only

06.08 1536 Rev M Updated 05/2020 © 2020 Victaulic Company. All rights reserved.

victaulic.com 2
victaulic.com

4.0 DIMENSIONS
Style 750 Reducing Coupling

Y Z Y Z

X X

Pipe End
Size Separation3 Deflect. From CL3 Bolt/Nut Dimensions Weight
Actual Outside Approximate
Nominal Diameter Allowable Per Cplg. Pipe Qty. Size X Y Z (Each)
inches inches inches in/ft inches inches inches inches lb
DN mm mm Degrees mm/m mm mm mm mm kg
2 1 2.375 1.315 0 - 0.07 0.20 3.38 5.28 1.88 2.7
x x 0° - 57' 2 3/8 x 2
DN50 DN25 60.3 33.7 0 - 1.8 17 85 134 48 1.2
1 1/2 1.900 0 - 0.07 0.20 3.38 5.28 1.88 2.0
0° - 57' 2 3/8 x 2
DN40 48.3 0 - 1.8 17 85 134 48 1.0
2 1/2 2 2.875 2.375 0 - 0.07 0.16 4.00 5.93 1.88 3.1
x x 0° - 47' 2 3/8 x 2
DN50 73.0 60.3 0 - 1.8 14 102 151 48 1.4
2 3.000 2.375 0 - 0.07 0.16 4.38 6.63 1.88 4.6
x x 0° - 47' 2 1/2 x 2 3/4
DN65 DN50 76.1 60.3 0 - 1.8 14 111 168 48 2.1
3 2 3.500 2.375 0 - 0.07 0.13 4.75 7.13 1.88 4.9
x x 0° - 39' 2 1/2 x 2 3/4
DN80 DN50 88.9 60.3 0 - 1.8 11 121 181 48 2.2
2 1/2 2.875 0 - 0.07 0.13 4.75 7.13 1.88 4.3
0° - 39' 2 1/2 x 2 3/4
73.0 0 - 1.8 11 121 181 48 2.0
3.00 0 - 0.07 0.13 4.75 7.13 1.88 4.2
0° - 39' 2 1/2 x 2 3/4
DN65 76.1 0 - 1.8 11 121 181 48 1.9
4 2 4.500 2.375 0 - 0.13 0.28 6.25 8.90 2.25 8.1
x x 1° - 19' 2 5/8 x 3 1/4
DN100 DN50 114.3 60.3 0 - 3.2 25 159 226 57 3.7
2 1/2 2.875 0 - 0.13 0.28 6.25 8.90 2.25 8.6
1° - 19' 2 5/8 x 3 1/4
73.0 0 - 3.2 25 159 226 57 3.9
3.000 0 - 0.13 0.28 6.25 8.90 2.25 6.9
1° - 19' 2 5/8 x 3 1/4
DN65 76.1 0 - 3.2 25 159 226 57 3.1
3 3.500 0 - 0.13 0.28 6.00 8.90 2.25 6.7
1° - 19' 2 5/8 x 3 1/4
DN80 88.9 0 - 3.2 25 152 226 57 3.0
5 4 5.563 4.500 0 - 0.13 0.22 7.18 10.70 2.13 11.2
x x 1° - 3' 2 3/4 x 4 1/4
DN100 141.3 114.3 0 - 3.2 19 182 272 54 5.1
4 6.500 4.500 0 - 0.13 0.19 8.63 11.90 2.25 15.2
x x 0° - 55' 2 3/4 x 4 1/4
165.1 DN100 165.1 114.3 0 - 3.2 16 219 302 57 6.9
6 4 6.625 4.500 0 - 0.13 0.18 8.63 11.90 2.25 16.7
x x 0° - 52' 2 3/4 x 4 1/4
DN150 DN100 168.3 114.3 0 - 3.2 15 219 302 57 7.6
5 5.563 0 - 0.13 0.18 8.31 11.90 2.25 12.9
0° - 52' 2 3/4 x 4 1/4
141.3 0 - 3.2 15 211 302 57 5.9
8 8.625 6.500 0 - 0.13 0.13 10.75 14.88 2.50 23.2
x x 0° - 38' 2 7/8 x 5
DN200 165.1 219.1 165.1 0 - 3.2 11 273 378 64 10.5
6 6.625 0 - 0.13 0.13 10.81 14.88 2.50 22.4
0° - 38' 2 7/8 x 5
DN150 168.3 0 - 3.2 11 275 378 64 10.2
10 8 10.750 8.625 0 - 0.13 0.90 13.12 17.26 2.62 31.4
x x 0° - 25' 2 1 x 5 1/2
DN250 DN200 273.0 219.1 0 - 3.2 8 333 438 67 14.2
3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe.
Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes, these figures should be reduced by:
50% for ¾ – 3 ½"/DN20 – DN90; and 25% for 4"/DN100 and larger.
NOTE
• Metric thread size bolts are available (color-coded gold) for all coupling sizes upon request. Contact Victaulic for details.

06.08 1536 Rev M Updated 05/2020 © 2020 Victaulic Company. All rights reserved.

victaulic.com 3
victaulic.com

5.0 PERFORMANCE
Style 750 Reducing Coupling

Size Maximum Maximum


Actual Outside Working End
Nominal Diameter Pressure4 Load4
inches inches psi lb
DN mm kPa N
2 1 2.375 1.315 350 500
x x
DN50 DN25 60.3 33.7 2413 2225
1 1/2 1.900 350 1000
DN40 48.3 2413 4450
2 1/2 2 2.875 2.375 500 2215
x x
DN50 73.0 60.3 3447 9850
2 3.000 2.375 350 1550
x x
DN65 DN50 76.1 60.3 2413 6900
3 2 3.500 2.375 350 1550
x x
DN80 DN50 88.9 60.3 2413 6900
2 1/2 2.875 500 3250
73.0 3447 14460
3.00 350 2475
DN65 76.1 2413 11010
4 2 4.500 2.375 350 1550
x x
DN100 DN50 114.3 60.3 2413 6900
2 1/2 2.875 350 2275
73.0 2413 10125
3.000 350 2475
DN65 76.1 2413 11014
3 3.500 500 4810
DN80 88.9 3447 21400
5 4 5.563 4.500 350 5565
x x
DN100 141.3 114.3 2413 24765
4 6.500 4.500 350 5565
x x
165.1 114.3 165.1 114.3 2413 24765
6 4 6.625 4.500 350 5565
x x
DN150 DN100 168.3 114.3 2413 24765
5 5.563 350 8500
141.3 2413 37825
8 8.625 6.500 350 11610
x x
DN200 165.1 219.1 165.1 2413 51645
6 6.625 350 12060
DN150 168.3 2413 53645
10 8 10.750 8.625 350 20450
x x
DN250 DN200 273.0 219.1 2413 90970
4 Working Presssure and End Load are total from all internal and external loads based on standard weight (ANSI) steel pipe standard roll or cut grooved in
accordance with Victaulic specifications. Contact Victaulic for performance on other pipe and material. Maximum working pressure rating based on larger pipe
size. Maximum end load rating based on smaller pipe size.
NOTES
• WARNING: FOR ONE-TIME FIELD USE ONLY the Maximum Joint Working Pressure may be increased to 1 ½ times the figures shown.
• For joint pressure ratings on additional carbon steel wall thicknesses see publication 06.15.

06.08 1536 Rev M Updated 05/2020 © 2020 Victaulic Company. All rights reserved.

victaulic.com 4
victaulic.com

5.1 PERFORMANCE
Flow Data - Head Loss
Equivalent lengths of standard weight steel pipe are shown in the tables. All data is based on water flowing at
+60°F/+16°C.

Flow Reducing Flow Expanding


Equivalent Equivalent
Size Pipe Length Size Pipe Length
Small Small
Nominal Diameter Nominal Diameter
inches ft inches ft
DN m DN m
2 1 5.9 1 2 2.7
x x
DN50 DN25 1.8 DN25 DN50 0.8
1 1/2 2.0 1 1/2 2 1.9
x
DN40 0.6 DN40 DN50 0.6
2 1/2 2 1.9 2 2 1/2 1.0
x x
DN50 0.6 DN50 0.3
2 1.9 1.0
x
DN65 DN50 0.6 DN65 0.3
3 2 5.5 3 3.5
x
DN80 DN50 1.7 DN80 1.1
2 1/2 3.8 4 3.0
1.2 DN100 0.9
3.8 2 1/2 3 2.5
x
DN65 1.2 DN80 0.8
4 2 6.0 4 3.0
x
DN100 DN50 1.8 DN100 0.9
2 1/2 6.0 3 2.5
x
1.8 DN65 DN80 0.8
6.0 4 3.0
DN65 1.8 DN100 0.9
3 6.0 3 4 2.5
x
DN80 1.8 DN80 DN100 0.8
5 4 3.0 4 5 3.3
x x
DN100 0.9 DN100 1.0
4 6.0 4.6
x
165.1 DN100 1.8 165.1 1.4
6 4 6.0 6 4.6
x
DN150 DN100 1.8 DN150 1.4
5 4.5 5 6 2.3
x
1.4 DN150 0.7
8 7.3 8 5.4
x x
DN200 165.1 2.2 165.1 DN200 1.7
6 7.3 6 8 6.0
x
DN150 2.2 DN150 DN200 1.8
10 8 8.7 8 10 6.3
x x
DN250 DN200 2.7 DN200 DN250 1.9

06.08 1536 Rev M Updated 05/2020 © 2020 Victaulic Company. All rights reserved.

victaulic.com 5
victaulic.com

6.0 NOTIFICATIONS

WARNING
• Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic
Couplings.
Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure,
resulting in serious personal injury and/or property damage.

WARNING

• Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic pip-
ing products.
­
• Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic
piping products.
• Wear safety glasses, hardhat, and foot protection.
• Only No. 61 bull plugs shall be used with Style 750 reducing couplings in systems where a vacuum may de-
velop.
Failure to follow these instructions could result in death or serious personal injury and property damage.

NOTICE

• Victaulic does not recommend the use of any furnace butt-welded pipe with sizes NPS 2”/DN50 and smaller
Victaulic gasketed joint products. This includes, but is not limited to, ASTM A53 Type F pipe.

7.0 REFERENCE MATERIALS


05.01: Victaulic Seal Selection Guide
06.15: Victaulic Pressure Ratings and End Loads for Victaulic Couplings on Steel Pipe
10.01: Victaulic Products for Fire Protection Piping Systems - Regulatory Approval Reference Guide
25.01: Victaulic Original Groove System (OGS) Groove Specifications
26.01: Victaulic Design Data
29.01: Victaulic Terms and Conditions of Sale
I-100: Victaulic Field Installation Handbook

User Responsibility for Product Selection and Suitability Note


Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products
Victaulic products for a particular end-use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions.
standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard
regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations.
instructions. Nothing in this or any other document, nor any verbal recommendation, Installation
advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to the Victaulic installation handbook or installation
or waive any provision of Victaulic Company's standard conditions of sale, installation instructions of the product you are installing. Handbooks are included with each shipment
guide, or this disclaimer. of Victaulic products, providing complete installation and assembly data, and are available
Intellectual Property Rights in PDF format on our website at www.victaulic.com.
No statement contained herein concerning a possible or suggested use of any material, Warranty
product, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details.
under any patent or other intellectual property right of Victaulic or any of its subsidiaries
or affiliates covering such use or design, or as a recommendation for the use of such Trademarks
material, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of
property right. The terms “Patented” or “Patent Pending” refer to design or utility patents Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries.
or patent applications for articles and/or methods of use in the United States and/or other
countries.

06.08 1536 Rev M Updated 05/2020 © 2020 Victaulic Company. All rights reserved.