1 Precautions
To use the device properly and safely, read the precautions carefully before using the device and
strictly observe these precautions when using the device.
Security warning and Precautions:
Do not look directly into the optical port without eye protection.
Keep the device out of the reach of children as the components or accessories may be
swallowed.
Install the device in strict compliance with the requirements of the supplier. Reserve a
space of at least 10 cm above and around the device for heat dissipation. During the
installation, keep the device away from electric appliances that generate strong magnetic
or electric fields, such as microwave ovens, refrigerators, and mobile phones.
The power supply voltage of the device must meet the requirements on the input voltage
of the device.
Do not use any power adapters that are not in the standard configuration. Otherwise, the
device may be abnormal or unsafe.
Dry your hands before connecting or disconnecting cables. Stop the device and switch
off the power before connecting or disconnecting cables.
Do not place any object on the device, so that the device will not be damaged due to
overheating or deformation.
Prevent objects, such as metal, from entering the device through the heat dissipation hole.
Switch off the power and disconnect all cables, including the power cable, optical fiber,
and network cable, during periods of lightning activities.
Do not lead the strength member of the optical fiber or other metal parts indoors. Do not
install telephone lines, network cables, power adapters or power adapter cables outdoors.
Adopting these measures will help prevent device damage and bodily injuries which are
especially prone during thunderstorms.
If an abnormality occurs, for example, liquid entering the device, smoke, unusual sound,
and smell, stop the device immediately, switch off the power, disconnect all cables (such
as the power cable, optical cable, and network cable) to the device, and contact the
authorized service center.
Do not disassemble the device without permission. In the case of a device fault, contact
the authorized service center.
Dispose of the packing materials, expired batteries, and old or abandoned devices in
accordance to local laws and regulations (recycling them is strongly recommended).
Do not change the structure, safety design, or performance design of the device without
prior authorization.
Fire Warning and Precautions:
The equipment needed to be far away from the large heat source, naked fire, and large
power equipment, such as electric heater, candles, hair dryer, avoid introducing safety
risk.
Near power lines - equipment or equipment, such as aging or aging cable plug board and
other facilities, please timely replacement, to avoid the introduction of safety risk.
2 Appearance
The MA5821/MA5822 is a box-type device 1U (1U = 44.45mm) high. The appearances of devices
using different modes are different.
Table 2-1 shows the appearances of the MA5821/MA5822.
Table 2-1 MA5821/MA5822 appearances
Configuration Appearances
MA5821 8FE
MA5821 16FE
MA5821 24FE
MA5821 8GE
MA5821 16GE
MA5821 24GE
MA5821 24GE,
PoE
MA5822
8FE+8POTS
MA5822
16FE+16POTS
Configuration Appearances
MA5822
24FE+24POTS
MA5822
8GE+8POTS
MA5822
16GE+16POTS
MA5822
24GE+24POTS
CAUTION
This is a Class A product. This product may cause radio interference, in which case the user
may be required to take practical precautions interference.
3 Installing the MA5821/MA5822
The configuration of MA5821/MA5822 can be installation in the 19-inch cabinet, chassis and
network cabinet.
Installation in the 19-inch cabinet
Step1 Install mounting ears
1.The air intake vent and the air exhaust vent of the network cabinet should keep expedite
for the MDU heat dissipation.
2.If the network cabinet is installed indoors or in a corridor that is out of rain, the network
cabinet must meet the requirements of IP31 class protection.(The first number "3" means
the solid particle with a diameter equal to or larger than 2.5 mm can be prevented from
entering the cabinet. The second number "1" means the drips fallen vertically cannot
damage the device. )
3.If the network cabinet is installed outdoors or in a corridor that is exposed to rain, the
network cabinet must meet the requirements of IP55 class protection. ( "IP" refers to
International Protection. The first number "5" refers to the class for preventing the solid
particle from entering the device. That is, the network cabinet cannot completely prevent
dust from entering the device, but the amount of dust that enters the network cabinet does
not damage the device. The second number "5" refers to the class for preventing water
from entering the network cabinet. That is, the water sprayed from different directions
to the network cabinet does not damage the device. )
CAUTION
>2 U
顶部
>2 U
The side
The GE electrical
port (above)
The optical port
(below)
The side
The GE electrical
port (above)
CAUTION
For better heat dissipation, avoid using the installation mode of placing the MDU vertically
(with the panel facing upwards) in the network cabinet.
Guide for grounding the network cabinet
TN-S power distribution system 1. MA5821/MA5822
L L 2. MDF
N 5 N 3. ODF
PGND 6 4 PE
1 4. Grounding bat
5. AC lightning protection
TN-C-S power distribution system bar
L L 6. AC power distribution
6 5 N cabinet
4 1 In the case of the TN-C-S and TN-S
PGND PE
AC power distribution systems, it is
recommended that you use the PE
wire of the AC power cable for the
MA5821/MA5822 grounding
connection. The prerequisite is that
the PE wire of the AC power cable
for the corridor of the building is
already grounded properly.
Use the ground cable (the cross-
sectional area of the ground cable
should be equal to or greater than 6
TN-S power distribution system mm2) to connect the grounding bar
and all the internal devices, and the
grounding bar to the network
cabinet in an equipotential manner
2 through a metallic structure.
MDF Connect the grounding point of the
reinforcing rib of the optical fiber to
1 the ground bar through a ground
cable, or connect this grounding
point to the network cabinet in an
4
equipotential manner through a
3 metallic structure.
ODF
Power cable
L N PE
CAUTION
1. The network cabinet must be grounded through an external ground cable (PGND
cable).
2. The network cabinet must be grounded through an external ground cable (PGND
cable).
3. A power cable with 3-5 m must be used for decoupling between the surge protector
and ONU power supply.
Grounding solution 1: The fiber strength member is isolated from the network box and grounded
outside the network box.
This solution prevents the introduction of sudden heavy currents into the network box, thereby
protecting the device inside the network box against heavy currents. (A long-distance armored
optical cable may introduce sudden heavy currents into the network box if the outer insulation
layer is broken and connects to a heavy-current power line.) Solution 1 is implemented as
follows:
1. Strip the outer insulation layer and armored tube from the fiber strength member at the
ground point. Then, clean bare optical fibers and use a protection tube to protect them. (Use
outdoor tubes in outdoor scenarios and common tubes in indoor or corridor scenarios. Use
waterproof tape produced by 3M or COTRAN.)
2. Use a piece of sandpaper to polish burrs at the stripped position of the optical cable. Then,
use insulation tape to wrap the stripped optical cable. When wrapping the waterproof tape,
ensure that fiber cores are force-free.
3. Cut excess fiber strength member for grounding.
Grounding solution 2: The fiber strength member is grounded inside a network box.
The fiber strength member must be connected to a ground bar at the ground point using a ground
cable. The ground point can connect to the network box using a metal in an equipotential manner.
When the fiber strength member connects to a heavy-current power line, heavy currents may be
discharged inside the network box using the ground bar. If this happens, sparks may occur at the
contact point between the fiber strength member and the ground bar, which may burn the device
and the network box. To prevent this issue from occurring, use solution .
Network box
CAUTION
220 V AC MDU
If the ground bar of the
Power cable ODF network cabinet fails to
securely ground, ensure
Ground bar that the fiber strength
member is disconnected
from the ground bar and
that the fiber strength
member is properly
Optical insulated. Otherwise,
fiber heavy currents may be
Fiber strength member discharged using the
network ports on the local
Strong-current discharge path and peer devices, which
may damage these
network ports.
4 Routing cables
Routing cables
Network cable AC power cable Optical fiber
Shield crystal head
PGND cable POTS subscriber cable
CAUTION
Correct ground cable connection ensures surge and interference protection. Therefore,
ensure that the device connects to the ground properly. If the device does not connect to the
ground properly, the device may be damaged due to lightning strikes, services carried on the
device may become abnormal, and even personal safety is threatened.
OT6-4
AC power cable
PGND cable
To AC power socket
Network cable
To subscriber device
CAUTION
Network cables cannot be directly used to connect FE or GE ports between the
MA5821 and MA5822.
If they are directly connected, FE or GE ports will be deactivate when the ring check
function is enabled.
If FE or GE ports are deactivated, perform the following to activate them:
1. Run the display ring check record command to query whether a ring network is
formed on ports.
2. Disconnect the network cable if a ring network is formed on ports.
3. Run the undo shutdown command to activate the port or run the ring check
resume-interval command to set the automatic port activation time to activate the port.
On the device side, cores of the POTS cable need to be crimpted by using the RJ11
connector.
Step5 Routing optical fiber
5 Description of LEDs
The MA5821/MA5822 provides a variety of indicators on its panel to help users learn about
the running status of the device.
RUN/ALM POTS