E-STOP Relays, Safety Gate Monitors: Pnoz Xv3.1P

This document summarizes a safety relay for monitoring emergency stop pushbuttons and safety gates. The relay can achieve up to Performance Level e in accordance with EN ISO 13849-1. It features positive-guided relay outputs, connection options for emergency stop devices and gates, and LED indicators. The relay meets safety requirements including redundant circuitry and self-monitoring to ensure the safety function remains effective even if a component fails.

Uploaded by

Jose Escobar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
366 views10 pages

E-STOP Relays, Safety Gate Monitors: Pnoz Xv3.1P

This document summarizes a safety relay for monitoring emergency stop pushbuttons and safety gates. The relay can achieve up to Performance Level e in accordance with EN ISO 13849-1. It features positive-guided relay outputs, connection options for emergency stop devices and gates, and LED indicators. The relay meets safety requirements including redundant circuitry and self-monitoring to ensure the safety function remains effective even if a component fails.

Uploaded by

Jose Escobar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

E-STOP relays, safety gate monitors

Up to PL e of EN ISO 13849-1
PNOZ XV3.1P

Unit features Unit description

` Positive-guided relay outputs: The safety relay meets the require-


Gertemerkmale Bestimmung/Gertebeschreibung NOT-AUS, Schutzt, Lichtschr_PNOZ

– 3 safety contacts (N/O), instanta- ments of EN 60947-5-1, EN 60204-1


neous and VDE 0113-1 and may be used in
– 2 safety contacts (N/O), delay-on applications with
de-energisation ` E-STOP pushbuttons
– 1 auxiliary contact (N/C), instan- ` Safety gates
taneous ` Light beam devices
` Connection options for: The max. category the safety contacts
Bestimmung/Gertebeschreibung_Kategorie_PNOZ

– E-STOP pushbutton can achieve in accordance with


– Safety gate limit switch EN 954-1 and EN ISO 13849-1 is stat-
Gertebild
– Light barriers ed in the technical details.
Safety relay for monitoring E-STOP
][Bildunterschrift – Reset button
pushbuttons and safety gates. ` Delay-on de-energisation, fixed or Safety features
adjustable
` Delay time can be cancelled via re- The relay meets the following safety
][Sicherheitseigenschaften Schaltgerät_allgemeiner Teil

Approvals
set button requirements:
` LED indicator for: ` The circuit is redundant with built-in
PNOZ XV3.1P – Switch status channel 1/2 self-monitoring.
– Supply voltage ` The safety function remains effec-
– Reset circuit tive in the case of a component fail-
‹ ` Plug-in connection terminals (either ure.
spring-loaded terminal or screw ` The correct opening and closing of
terminal) the safety function relays is tested
‹ ` See order reference for unit types automatically in each on-off cycle.
` The tranformer is short circuit-
Sicherheitseigenschaften Zusatz - AC/DC-Gerte_PNOZ

proof. An electronic fuse is used on


‹ a DC supply.

Zulassungen

Block diagram
il
tb
a
h
s
k
c
lo
B
d

A1 A2 S11 S12 S21 S22 S31 S32 13 23 33 57 67 41

~ Input Input Input


K3
=
K1

Power
Power K4

Reset/ Reset/ Reset K2


Start Start
t

S13 S14 S33 S34 Y39 Y40 14 24 34 58 68 42


UB AC

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-298-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
E-STOP relays, safety gate monitors

Up to PL e of EN ISO 13849-1
PNOZ XV3.1P

Function description and, with a monitored reset, in ` Automatic start: Unit is active once
][Funktionen_autoStart

the reset circuit too, the input circuit has been closed.
` Single-channel operation: no re- – shorts between contacts in the ` Monitored reset: Unit is active once
][Funktionen_einkanalig_Erd_Start ][Funktionen_berStart_Wartezeit

dundancy in the input circuit, earth input circuit. the input circuit is closed and once
faults in the reset circuit are detect- ` Dual-channel operation without de- the reset circuit is closed after the
][Funktionen_zweikanalig_ohne_quer

ed. tection of shorts across contacts: waiting period has elapsed


` Dual-channel operation with detec- redundant input circuit, detects (see technical details).
][Funktionen_zweikanalig_mit_quer_ber

tion of shorts across contacts: re- – earth faults in the reset and input ` Increase in the number of available
][Funktionen_Kontaktvervielfachung

dundant input circuit, detects circuit, instantaneous safety contacts by


– earth faults in the reset and input – short circuits in the input circuit connecting contact expansion
circuit, and, with a monitored reset, in modules or external contactors.
– short circuits in the input circuit the reset circuit too.

Timing diagram
l
x
2
b
o
u
_
rm
g
a
itd
e
][Z

1 2

POWER

Reset/Start

Reset tv

Input

Output safe

Output aux

Output safe del


t1 t2 t3 t1 t2 t3 t4 t1 t2 t3 t5 t4 t1 t2 t3

Key
` Power: Supply voltage ` Output safe del: Safety contacts, ` t2: Delay-on de-energisation
` Reset/Start: Reset circuit S13-S14, delayed 57-58, 67-68 ` t3: Delay time
S33-S34 ` Output aux: Auxiliary contacts 41- ` t4: Waiting period
` Input: Input circuits S11-S12, S21- 42
` t5: Recovery time
S22, S31-S32 ` c: Automatic reset
` Output safe: Safety contacts, in- ` d: Monitored reset
stantaneous 13-14, 23-24, 33-34 ` t1: Switch-on delay

Wiring

Please note:
][Verdrahtung_Si_unverz_verz_1Hi_unverz

Rlmax
` Information given in the “Technical Imax =
Rl / km
details” must be followed.
` Outputs 13-14, 23-24, 33-34 are in- Rlmax = max. overall cable resist-
stantaneous safety contacts, out- ance (see technical details)
puts 57-58, 67-68 are delay-on de- Rl /km = cable resistance/km
energisation safety contacts, out- ` Use copper wire that can withstand
put 41-42 is an instantaneous auxil- 60/75 °C.
iary contact (e.g. for display). ` Sufficient fuse protection must be
` To prevent contact welding, a fuse provided on all output contacts with
should be connected before the capacitive and inductive loads.
output contacts (see technical de-
tails).
` Calculation of the max. cable runs
lmax in the input circuit:

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-298-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

-2
E-STOP relays, safety gate monitors

Up to PL e of EN ISO 13849-1
PNOZ XV3.1P

Preparing for operation


Betriebsbereitschaft herstellen

` Supply voltage

Supply voltage AC DC

A1 L1 A1 L+
A2 N

PE A2 L-

` Input circuit

Input circuit Single-channel Dual-channel


E-STOP S1 S1
without detection of shorts across con- S12 S11
tacts S21 S11 S21
S22 S32 S22 S12
S31 S32

E-STOP S1
with detection of shorts across contacts S22
S11 S32
S12 S31
S21

Safety gate
without detection of shorts across con-
tacts
S1
S12 S11
S21 S1
S11 S21 S2
S22 S32 S22 S12
S31 S32

Safety gate
with detection of shorts across contacts

S22
S1
S11 S21 S2
S12 S32
S31

Light beam device 24 V DC


S21
with detection of shorts across contacts
S22
via ESPE
(only when UB = 24 VDC) A2 S12
S32
GND

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-298-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
E-STOP relays, safety gate monitors

Up to PL e of EN ISO 13849-1
PNOZ XV3.1P

` Reset circuit

Reset circuit E-STOP wiring (single-channel), E-STOP wiring (dual-channel)


Safety gate (single-channel) Safety gate (dual-channel)
Automatic reset
S13 S13

S14 S14

Monitored reset S3 S3
S33 S33

S34 S34

` Reset delay time

Reset Without reset With reset


Link or N/C contact
Y39 Y39
Y40

Y40

` Feedback circuit

Feedback circuit Automatic reset Monitored reset


Contacts from external contactors S3
S13 S33
K5 K6 K5 K6
S14 S34
13 (23, 33) L1 13 (23, 33) L1
K5 N K5
14 (24, 34) 14 (24 ,34) N
K6 K6

` Key

S1/S2 E-STOP/safety gate switch


S3 Reset button

Switch operated

Gate open

Gate closed

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-298-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

-4
E-STOP relays, safety gate monitors

Up to PL e of EN ISO 13849-1
PNOZ XV3.1P

Terminal configuration
u
g
b
n
m
le
K

Installation Dimensions

` The safety relay should be installed * with spring-loaded terminals


Montage_PNOZ_X
Montage Abmessungen

in a control cabinet with a protec-


tion type of at least IP54.
` Use the notch on the rear of the unit
to attach it to a DIN rail.
` Ensure the unit is mounted securely
121 (4.76")

on a vertical DIN rail (35 mm) by us-


ing a fixing element (e.g. retaining
bracket or an end angle).

94 (3.70") 90
(3.54")
* 101 (3.98")

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-298-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
E-STOP relays, safety gate monitors

Up to PL e of EN ISO 13849-1
PNOZ XV3.1P

Notice Service life graph

This data sheet is only intended for use


][WICHTIG_PDB_alt v
rk
u
a
d
s
n
b
e
L

Corrente di esercizio nominale (A)


during configuration. For installation

Corriente nominal de servicio (A)


10
and operation, please refer to the op- AC15: 230 V

Nominale bedrijfsstroom (A)


erating instructions supplied with the

Nominal operating current (A)


DC1: 24 V
unit.
Nennbetriebstrom (A) DC13: 24 V
AC1: 230 V
Courant coupé (A) 1

0.1
GB

NL
D

E
F

10 100 1000 10000


I

D Schaltspielzahl x 103 E Número de ciclos x 103


GB Cycles x 103 I Numero dei cicli di commutazione x 103
F Nombre de manœuvres x 103 NL Aantal schakelingen x 103
][Technische Daten PNOZ verzögert

Technical details

Electrical data
Supply voltage
Supply voltage UB DC 24 V
Supply voltage UB AC/DC 24 - 240 V
Voltage tolerance -15 %/+10 %
Power consumption at UB AC 8.5 VA Order no.: 777530, 777532, 777538, 787530, 787532,
787538
Power consumption at UB DC 4.5 W Order no.: 777520, 777522, 777525, 787520, 787522
5.0 W Order no.: 777530, 777532, 777538, 787530, 787532,
787538
Frequency range AC 50 - 60 Hz
Residual ripple DC 160 %
Voltage and current at
Input circuit DC: 24.0 V 40.0 mA Order no.: 777530, 777532, 777538, 787530, 787532,
787538
50.0 mA Order no.: 777520, 777522, 777525, 787520, 787522
Reset circuit DC: 24.0 V 40.0 mA
Feedback loop DC: 24.0 V 3.1 mA
Number of output contacts
Safety contacts (S) instantaneous: 3
Safety contacts (N/O), delayed: 2
Auxiliary contacts (N/C): 1

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-298-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

-6
E-STOP relays, safety gate monitors

Up to PL e of EN ISO 13849-1
PNOZ XV3.1P

Electrical data
Utilisation category in accordance with EN 60947-4-1
Safety contacts: AC1 at 240 V Imin: 0.01 A , Imax: 8.0 A
Pmax: 2000 VA
Safety contacts: DC1 at 24 V Imin: 0.01 A , Imax: 8.0 A
Pmax: 200 W
Safety contacts, delayed: AC1 at 240 V Imin: 0.01 A , Imax: 8.0 A
Pmax: 2000 VA
Safety contacts, delayed: DC1 at 24 V Imin: 0.01 A , Imax: 8.0 A
Pmax: 200 W
Auxiliary contacts: AC1 at 240 V Imin: 0.01 A , Imax: 8.0 A
Pmax: 2000 VA
Auxiliary contacts: DC1 at 24 V Imin: 0.01 A , Imax: 8.0 A
Pmax: 200 W
Utilisation category in accordance with EN 60947-5-1
Safety contacts: AC15 at 230 V Imax: 5.0 A
Safety contacts: DC13 at 24 V (6 cycles/min) Imax: 7.0 A
Safety contacts, delayed: AC15 at 230 V Imax: 5.0 A
Safety contacts, delayed: DC13 at 24 V (6 cycles/min) Imax: 7.0 A
Auxiliary contacts: AC15 at 230 V Imax: 5.0 A
Auxiliary contacts: DC13 at 24 V (6 cycles/min) Imax: 7.0 A
Contact material AgSnO2 + 0.2 µm Au
External contact fuse protection (IK = 1 kA) to EN 60947-5-1
Blow-out fuse, quick
Safety contacts: 10 A
Safety contacts, delayed: 10 A
Auxiliary contacts: 10 A
Blow-out fuse, slow
Safety contacts: 6A
Safety contacts, delayed: 6A
Auxiliary contacts: 6A
Circuit breaker 24 VAC/DC, characteristic B/C
Safety contacts: 6A
Safety contacts, delayed: 6A
Auxiliary contacts: 6A
Max. overall cable resistance Rlmax
input circuits, reset circuits
single-channel at UB DC 100 Ohm Order no.: 777520, 777522, 777525, 787520, 787522
150 Ohm Order no.: 777530, 777532, 777538, 787530, 787532,
787538
single-channel at UB AC 150 Ohm Order no.: 777530, 777532, 777538, 787530, 787532,
787538
dual-channel without detect. of shorts across contacts at UB DC 120 Ohm Order no.: 777520, 777522, 777525, 787520, 787522
200 Ohm Order no.: 777530, 777532, 777538, 787530, 787532,
787538
dual-channel without detect. of shorts across contacts at UB AC 200 Ohm Order no.: 777530, 777532, 777538, 787530, 787532,
787538
dual-channel with detect. of shorts across contacts at UB DC 10 Ohm Order no.: 777520, 777522, 777525, 787520, 787522
20 Ohm Order no.: 777530, 777532, 777538, 787530, 787532,
787538
dual-channel with detect. of shorts across contacts at UB AC 20 Ohm Order no.: 777530, 777532, 777538, 787530, 787532,
787538
Safety-related characteristic data
PL in accordance with EN ISO 13849-1
Safety contacts, instantaneous PL e (Cat. 4)
Safety contacts, delayed <30 s PL d (Cat. 3)
Safety contacts, delayed ≥30 s PL c (Cat. 1)

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-298-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
E-STOP relays, safety gate monitors

Up to PL e of EN ISO 13849-1
PNOZ XV3.1P

Safety-related characteristic data


Category in accordance with EN 954-1
Safety contacts, instantaneous Cat. 4
Safety contacts, delayed <30 s Cat. 3
Safety contacts, delayed ≥30 s Cat. 1
SIL CL in accordance with EN IEC 62061
Safety contacts, instantaneous SIL CL 3
Safety contacts, delayed <30 s SIL CL 3
Safety contacts, delayed ≥30 s SIL CL 1
PFH in accordance with EN IEC 62061
Safety contacts, instantaneous 2.31E-09
Safety contacts, delayed <30 s 2.64E-09
Safety contacts, delayed ≥30 s 2.87E-09
SIL in accordance with IEC 61511
Safety contacts, instantaneous SIL 3
Safety contacts, delayed <30 s SIL 3
Safety contacts, delayed ≥30 s SIL 2
PFD in accordance with IEC 61511
Safety contacts, instantaneous 2.03E-06
Safety contacts, delayed <30 s 1.26E-05
Safety contacts, delayed ≥30 s 4.64E-05
tM in years 20
Times
Switch-on delay
with automatic reset typ. 400 ms
with automatic reset max. 550 ms Order no.: 777530, 777532, 777538, 787530, 787532,
787538
850 ms Order no.: 777520, 777522, 777525, 787520, 787522
with automatic reset after power on typ. 400 ms Order no.: 777520, 777522, 777525, 787520, 787522
625 ms Order no.: 777530, 777532, 777538, 787530, 787532,
787538
with automatic reset after power on max. 870 ms
on monitored reset with rising edge typ. 35 ms Order no.: 777530, 777532, 777538, 787530, 787532,
787538
40 ms Order no.: 777520, 777522, 777525, 787520, 787522
on monitored reset with rising edge max. 60 ms Order no.: 777530, 777532, 777538, 787530, 787532,
787538
70 ms Order no.: 777520, 777522, 777525, 787520, 787522
Delay-on de-energisation
with E-STOP typ. 15 ms
with E-STOP max. 30 ms
with power failure typ. 110 ms Order no.: 777520, 777522, 777525, 787520, 787522
with power failure max. 150 ms Order no.: 777520, 777522, 777525, 787520, 787522
with power failure typ. UB DC: 24 V Order no.: 777530, 777532, 90 ms Order no.: 777530, 777532, 777538, 787530, 787532,
777538, 787530, 787532, 787538 787538
with power failure typ. UB AC/DC: 24 V Order no.: 777530, 90 ms Order no.: 777530, 777532, 777538, 787530, 787532,
777532, 777538, 787530, 787532, 787538 787538
with power failure max. UB DC: 24 V Order no.: 777530, 777532, 250 ms Order no.: 777530, 777532, 777538, 787530, 787532,
777538, 787530, 787532, 787538 787538
with power failure max. UB AC/DC: 24 V Order no.: 777530, 250 ms Order no.: 777530, 777532, 777538, 787530, 787532,
777532, 777538, 787530, 787532, 787538 787538
with power failure typ. UB AC : 240 V 815 ms Order no.: 777530, 777532, 777538, 787530, 787532,
787538
with power failure max. UB AC : 240 V 1900 ms Order no.: 777530, 777532, 777538, 787530, 787532,
787538

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-298-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

-8
E-STOP relays, safety gate monitors

Up to PL e of EN ISO 13849-1
PNOZ XV3.1P

Times
Recovery time at max. switching frequency 1/s
after E-STOP 50 ms +tv
after power failure 200 ms Order no.: 777520, 777522, 777525, 787520, 787522
after power failure on universal power supply 2000 ms Order no.: 777530, 777532, 777538, 787530, 787532,
787538
Delay time tV: selectable 0,00 s; 0,50 s; 1,00 s; 2,00 s; 4,00 s; 6,00 s; 8,00 s; 10,00 s;
15,00 s; 20,00 s; 25,00 s; 30,00 s Order no.: 777520
0,10 s; 0,20 s; 0,30 s; 0,40 s; 0,50 s; 0,60 s; 0,70 s; 0,80 s; 1,00 s;
1,50 s; 2,00 s; 3,00 s Order no.: 777522
0,00 s; 0,50 s; 1,00 s; 2,00 s; 4,00 s; 6,00 s; 8,00 s; 10,00 s;
15,00 s; 20,00 s; 25,00 s; 30,00 s Order no.: 777530
0,10 s; 0,20 s; 0,30 s; 0,40 s; 0,50 s; 0,60 s; 0,70 s; 0,80 s; 1,00 s;
1,50 s; 2,00 s; 3,00 s Order no.: 777532
0,00 s; 5,00 s; 10,00 s; 20,00 s; 40,00 s; 60,00 s; 80,00 s;
100,00 s; 150,00 s; 200,00 s; 250,00 s; 300,00 s Order no.:
777538
0,00 s; 0,50 s; 1,00 s; 2,00 s; 4,00 s; 6,00 s; 8,00 s; 10,00 s;
15,00 s; 20,00 s; 25,00 s; 30,00 s Order no.: 787520
0,10 s; 0,20 s; 0,30 s; 0,40 s; 0,50 s; 0,60 s; 0,70 s; 0,80 s; 1,00 s;
1,50 s; 2,00 s; 3,00 s Order no.: 787522
0,00 s; 0,50 s; 1,00 s; 2,00 s; 4,00 s; 6,00 s; 8,00 s; 10,00 s;
15,00 s; 20,00 s; 25,00 s; 30,00 s Order no.: 787530
0,10 s; 0,20 s; 0,30 s; 0,40 s; 0,50 s; 0,60 s; 0,70 s; 0,80 s; 1,00 s;
1,50 s; 2,00 s; 3,00 s Order no.: 787532
0,00 s; 5,00 s; 10,00 s; 20,00 s; 40,00 s; 60,00 s; 80,00 s;
100,00 s; 150,00 s; 200,00 s; 250,00 s; 300,00 s Order no.:
787538
Delay time tV: fixed 3.00 s Order no.: 777525
Repetition accuracy 2%
Time accuracy -15 %/+15 % +50 ms
Waiting period with a monitored reset
with rising edge 300 ms
Min. start pulse duration with a monitored reset
with rising edge 30 ms
Simultaneity, channel 1 and 2 ∞
Supply interruption before de-energisation 20 ms
Environmental data
EMC EN 60947-5-1, EN 61000-6-2, EN 61000-6-4
Vibration to EN 60068-2-6
Frequency 10 - 55 Hz
Amplitude 0.35 mm
Climatic suitability EN 60068-2-78
Airgap creepage in accordance with EN 60947-1
Pollution degree 2
Overvoltage category III
Rated insulation voltage 250 V
Rated impulse withstand voltage 4.0 kV
Ambient temperature -10 - 55 °C
Storage temperature -40 - 85 °C
Protection type
Mounting (e.g. cabinet) IP54
Housing IP40
Terminals IP20
Mechanical data
Housing material
Housing PPO UL 94 V0
Front ABS UL 94 V0

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-298-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
E-STOP relays, safety gate monitors

Up to PL e of EN ISO 13849-1
PNOZ XV3.1P

Mechanical data
Cross section of external conductors with screw terminals
1 core flexible 0.25 - 2.50 mm² , 24 - 12 AWG Order no.: 777520, 777522,
777525, 777530, 777532, 777538
2 core, same cross section, flexible:
with crimp connectors, without insulating sleeve 0.25 - 1.00 mm² , 24 - 16 AWG Order no.: 777520, 777522,
777525, 777530, 777532, 777538
without crimp connectors or with TWIN crimp connectors 0.20 - 1.50 mm² , 24 - 16 AWG Order no.: 777520, 777522,
777525, 777530, 777532, 777538
Torque setting with screw terminals 0.50 Nm Order no.: 777520, 777522, 777525, 777530, 777532,
777538
Cross section of external conductors with spring-loaded termi- 0.20 - 1.50 mm² , 24 - 16 AWG Order no.: 787520, 787522,
nals: Flexible with/without crimp connectors 787530, 787532, 787538
Spring-loaded terminals: Terminal points per connection 2 Order no.: 787520, 787522, 787530, 787532, 787538
Stripping length 8 mm Order no.: 787520, 787522, 787530, 787532, 787538
Dimensions
Height 101.0 mm Order no.: 787520, 787522, 787530, 787532, 787538
94.0 mm Order no.: 777520, 777522, 777525, 777530, 777532,
777538
Width 90.0 mm
Depth 121.0 mm
Weight 500 g Order no.: 787520, 787522
510 g Order no.: 777520, 777522, 777525
570 g Order no.: 787530, 787532, 787538
580 g Order no.: 777530, 777532, 777538
Technische Daten_Satz Normen

The standards current on 2008-07 apply.


][Dauerstrom_ACDC

Conventional thermal current

Number of contacts Ith (A) at UB DC Ith (A) at UB AC


1 8.00 A 8.00 A Order no.: 777530, 777532, 777538, 787530,
787532, 787538
2 7.80 A 7.80 A Order no.: 777530, 777532, 777538, 787530,
787532, 787538
3 6.50 A 6.50 A Order no.: 777530, 777532, 777538, 787530,
787532, 787538
4 5.50 A 5.50 A Order no.: 777530, 777532, 777538, 787530,
787532, 787538
5 5.00 A 5.00 A Order no.: 777530, 777532, 777538, 787530,
787532, 787538
Bestelldaten

Order reference

Type Features Terminals Order no.


PNOZ XV3.1P C 24 VDC 30 s selectable Spring-loaded terminals 787 520
PNOZ XV3.1P 24 VDC 30 s selectable Screw terminals 777 520
PNOZ XV3.1P C 24 VDC 3 s selectable Spring-loaded terminals 787 522
PNOZ XV3.1P 24 VDC 3 s selectable Screw terminals 777 522
PNOZ XV3.1P 24 VDC 3 s fixed Screw terminals 777 525
PNOZ XV3.1P C 24 - 240 VAC/DC 30 s selectable Spring-loaded terminals 787 530
PNOZ XV3.1P 24 - 240 VAC/DC 30 s selectable Screw terminals 777 530
PNOZ XV3.1P C 24 - 240 VAC/DC 3 s selectable Spring-loaded terminals 787 532
PNOZ XV3.1P 24 - 240 VAC/DC 3 s selectable Screw terminals 777 532
PNOZ XV3.1P C 24 - 240 VAC/DC 300 s selectable Spring-loaded terminals 787 538
PNOZ XV3.1P 24 - 240 VAC/DC 300 s selectable Screw terminals 777 538

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-298-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

-10

You might also like