PRODUCT DATA

BACnet/Modbus Carrier
Translator

The BACnet/Modbus Carrier Translator is a micro con-


troller-based module that provides the ability to inte-
grate Carrier CCN-based controllers into Modbus and
BACnet networks. The BACnet/Modbus Carrier Trans-
lator (33CNTRAN485) provides CCN to Modbus Re-
mote Terminal Unit (RTU) and BACnet Master-Slave/
Token-Passing (MS/TP) protocol conversion.

The Carrier Translator can be mounted in the controls


section of any CCN equipment and converts CCN-
based controller data to BACnet or Modbus. The Car-
rier Translator is outdoor duty rated and contains CCN
RS-485 and BACnet/Modbus communications connec-
tors.
SPECIFICATIONS
When connected to a CCN controller, the BACnet/
Modbus Carrier Translator allows a third party BACnet Power Requirements .............. 3 VA @ 24 Vac + 25%
or Modbus device to read and write to the CCN
controller’s mapped status display, time schedule, and Dimensions ......................... 2.1 in H x 5 in W x 4 in D
setpoint schedule data. Note that status display write (53.3 mm x 127 mm x 101.6 mm)
access is subject to the CCN equipment controller’s
defined read/write access for each status display item. Operating Temperature ......................... -40°F to 158°F
(-40°C to 70°C)
FEATURES
Storage Temperature ............................ -40°F to 185°F
• 3-wire removable BACnet/Modbus connector (-40°C to 85°C)
• 3-wire fixed screw terminal CCN connector
• 2-wire fixed screw terminal Power connector Operating Humidity ........... 0 to 95%, non-condensing
• Red Processor Status LED
• Yellow CCN Communication Status LED CCN Communications .......... 9600, 19.2K, 38.4K baud
• Green BACnet/Modbus Communication Status LED
BACnet MS/TP Communications ................... EIA-485
at 9600, 19.2K, 38.4K baud

Modbus RTU Communications ....................... EIA-485


at 9600, 19.2K, 38.4K baud
Data Bits .............................................................. 8
Parity .......................................... Odd, Even, None
Stop Bits ........................................................ 0,1,2
Flow Control ............................... None, XON/XOFF

Conforms to guidelines for radiated and conducted emis-


sions for a Class A device as stated in FCC Rules and
Regulations Part 15, Subpart J.

UL 916 and CE MARK (industrial) listed.

Specifications subject to change without notice © 2005, Carrier Corporation Printed in U.S.A.