Product Model Number Guide 120417
Product Model Number Guide 120417
MODEL NUMBER
GUIDE
gForce IR
MODEL NUMBER IDENTIFICATION
GI CW - 035 3 4
Voltage
2 - 208/230 volt
Data Aire gForce IR
4 - 460 volt
Single Circuit
Phase
AX------Air Cooled 1 - Single Phase
WX - Water Cooled 3 - Three phase
GX - Glycol Cooled
CW - Chilled Water
Nominal Kilowatts
010kW -AX *
020kW -AX *
12” Cabinet: 030kW -CW
GT Systems
MODEL NUMBER IDENTIFICATION
GT A D - 035 3 4 C
C - Auxillary Chilled Water Coil
(Air or Water Cooled Units)
gForce Series
Single Circuit E - Energy Saver Coil
(Water/Glycol Cooled Units)
A------Air Cooled
Voltage
W - Water Cooled
2 - 208 or 230 V
G - Glycol Cooled 4 - 460 V
5 - 575 V
D - Downflow
U ---- Upflow Phase
1 - Single Phase
Nominal Kilowatts 3 - Three phase
007-046 kW
D - Downflow
U ---- Upflow Phase
1 - Single Phase
3 - Three phase
Nominal Kilowatts
021 - 106 kW
DT A D - 05 1 2 - C
C - Auxillary Chilled Water Coil
(Air or Water Cooled Units)
DATA TEMP
E - Energy Saver Coil
A--------Air Cooled (Water/Glycol Cooled Units)
W --- Water Cooled
G --- Glycol Cooled Voltage
C --- Chilled Water 2 - 208 or 230 V
4 - 460 V
D - Downflow 5 - 575 V
U ---- Upflow
Phase
1 - Single Phase
Nominal tons
2-5 tons 3 - Three phase
DT A D - 08 3 2
Voltage
MODULAR 2 - 208 or 230 V
DATA TEMP 4 - 460 V
5 - 575 V
U ---- Upflow
D - Downflow
Nominal tons
8-13 tons
A------Air Cooled
Voltage
W - Water Cooled
2 - 208 or 230 V
G - Glycol Cooled
4 - 460 V
5 - 575 V
D - Downflow
U --- Upflow Phase
3 - Three phase
Nominal tons
06 - 30 tons
Nominal tons
07 - 50 tons
DAP A - 2.5 1 2 - E - CO
P - Package System
DATA AIRE MINI-PLUS
CO - Split system with
CEILING SYSTEM outdoor condenser
A ------ Air Cooled (DARC)
G --- Glycol Cooled CI - Split systems with
W -- Water Cooled indoor condenser
C --- Chilled Water (DAIC)
DAL A - 06 3 2 - E - CO- D
DATA AIRE LCS UNIT D - Dual Compressor
Single or Dual Circuit
S - Single Compressor
A ------ Air Cooled
G --- Glycol Cooled P - Package System
W --- Water Cooled
CO - Split system with
C --- Chilled Water
outdoor condenser
(DARC)
Nominal tons
06, 08, 10 and 13
LCS units are not available in air cooled packaged configuration. AO - Split system with
CONDENSER - Condenser coil only, no compressor
outdoor condensing unit
CONDENSING UNIT - Condenser coil and compressor
Phase (DRCU)
3 - Three Phase
The order write up should have the condenser or condensing unit model number.
Refer to applicable condenser or condensing model number identification. C - Auxilary chilled
Voltage water coil
Example: DATA AIRE LCS UNIT, air cooled, 6 ton, 30 - 230 volts, split system with 2 - 208 or 230 V
outdoor condenser and dual compressors - E - Energy Saver
Evaporator model: DALA 0632 CO D Condenser model: DARC 0632
4 - 460 V
5 - 575 V
Model
DARC 07xx-PB
DARC 09xx-PB DARC 07xx-PB to DARC 09xx-PB are single fan units.
DARC 11xx-PB
DARC 15xx-PB
DARC 17xx-PB
DARC 21xx-PB DARC 11xx-PB to DARC 28xx-PB are dual fan units.
DARC 24xx-PB
DARC 28xx-PB
FC - Fluid Cooler
Voltage
2 - 208 or 230 volt
Nominal tons
4 - 460 volt
Phase
1 - Single Phase
3 - Three Phase
Model
• DAFC-06-PB
• DAFC-07-PB
• DAFC -09-PB
• DAFC -11-PB
• DAFC -15-PB
• DAFC -17-PB
• DAFC -21-PB
• DAFC-28-PB
Nominal tons
02 and 03
Shelf Systems
MODEL NUMBER IDENTIFICATION
DAS A - 02 1 2 - CO
P - Package System
DATA AIRE Fluid cooler identification
SHELF SYSTEM may be required for glycol
Single Circuit cooled units. (DAFC)