Product Model Number Guide 120417

This document provides a guide to product model numbering for cooling systems. It includes 18 figures that illustrate the model numbering structures for different product types, including floor units, rack/row units, ceiling units, and outdoor components. The model numbers convey information about the system type, configuration, voltage, phase, and nominal cooling capacity.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
271 views12 pages

Product Model Number Guide 120417

This document provides a guide to product model numbering for cooling systems. It includes 18 figures that illustrate the model numbering structures for different product types, including floor units, rack/row units, ceiling units, and outdoor components. The model numbers convey information about the system type, configuration, voltage, phase, and nominal cooling capacity.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

PRODUCT

MODEL NUMBER
GUIDE

Product Model Number Guide


12.04.17
1
TABLE OF FIGURES

Figure 1 - gForce Ultra Systems (Single & Dual Circuit)..........................................3

Figure 2 – gForce In-Row Systems (Single Circuit)...................................................3

Figure 3 - GT Systems (Single Circuit).......................................................................4

Figure 4 - gForce Systems (Dual Circuit)...................................................................5

Figure 5 - Data Temp Systems (Single Circuit).........................................................6

Figure 6 - Modular Data Temp Systems (Single Circuit).........................................6

Figure 7 - Data Aire Systems (DX)..............................................................................7

Figure 8 - Data Aire Systems (Chilled Water)...........................................................7

Figure 9 - Mini Ceiling Systems (Single Circuit).......................................................8

Figure 10 - Mini-Plus Ceiling Systems (Single Circuit)............................................8

Figure 11 - Large Ceiling Systems (Single OR Dual Circuit)...................................9

Figure 12 – Outdoor Remote Condensers (RC).....................................................10

Figure 13 - Outdoor Condensing Units (CU).........................................................10

Figure 14 - Indoor “Piggy-Back” Remote Condenser (RC + PB)..........................10

Figure 15 - Outdoor Fluid Coolers (FC)..................................................................11

Figure 16 – Indoor “Piggy-Back” Fluid Cooler (FC + PB)......................................11

Figure 17 - Data Cool Systems (Single Circuit)......................................................12

Figure 18 - Shelf Systems (Single Circuit)...............................................................12

Product Model Number Guide


2
12.04.17
FLOOR UNITS (VARIABLE SPEED COMPRESSOR)

Note: Each image will hyperlink gForce Ultra


to our website and the product’s MODEL NUMBER IDENTIFICATION
supporting documentation GU A U - 022 3 2

gForce Ultra, Voltage


Single and Dual Circuit 2 - 208/230 V
4 - 460 V
A----- Air Cooled
Phase
W - Water Cooled 3 - Three phase
G - Glycol Cooled

D - Downflow Nominal Kilowatts


U ---- Upflow 022kW
036kW
045kW
070kW
091kW
125kW
single circuit: 022, 036, 045
dual: 070, 091, 125

Figure 1 - gForce Ultra Systems (Single & Dual Circuit)

RACK & ROW(FIXED/VARIABLE SPEED COMPRESSOR:

gForce IR
MODEL NUMBER IDENTIFICATION
GI CW - 035 3 4

Voltage
2 - 208/230 volt
Data Aire gForce IR
4 - 460 volt
Single Circuit
Phase
AX------Air Cooled 1 - Single Phase
WX - Water Cooled 3 - Three phase
GX - Glycol Cooled
CW - Chilled Water
Nominal Kilowatts
010kW -AX *
020kW -AX *
12” Cabinet: 030kW -CW

24” Cabinet: 022kW -AX, WX or GX **


035kW -AX, WX or GX **
060kW -CW
12” cabinet 24” cabinet
* Fixed speed compressor
Figure 2 - gForce In-Row Systems (Single Circuit) ** Variable speed compressor

Product Model Number Guide


12.04.17
3
FLOOR UNITS

GT Systems
MODEL NUMBER IDENTIFICATION
GT A D - 035 3 4 C
C - Auxillary Chilled Water Coil
(Air or Water Cooled Units)
gForce Series
Single Circuit E - Energy Saver Coil
(Water/Glycol Cooled Units)
A------Air Cooled
Voltage
W - Water Cooled
2 - 208 or 230 V
G - Glycol Cooled 4 - 460 V
5 - 575 V
D - Downflow
U ---- Upflow Phase
1 - Single Phase
Nominal Kilowatts 3 - Three phase
007-046 kW

Figure 3 - GT Systems (Single Circuit)

Product Model Number Guide


4
12.04.17
gForce Systems
MODEL NUMBER IDENTIFICATION
GF A D - 035 3 4 E
C - Auxillary Chilled Water Coil
gForce Systems (Air or Water Cooled Units)
Dual Circuit
E - Energy Saver Coil
(Water/Glycol Cooled Units)
A ------ Air Cooled
W --- Water Cooled
Voltage
G --- Glycol Cooled
2 - 208 or 230 V
C --- Chilled Water 3 - 380 or 400 V
4 - 460 V

D - Downflow
U ---- Upflow Phase
1 - Single Phase
3 - Three phase
Nominal Kilowatts
021 - 106 kW

Figure 4 - gForce Systems (Dual Circuit)

DX Units (Link) Chilled Water Units (Link)

Product Model Number Guide


12.04.17
5
FLOOR UNITS (Cont.)

Data Temp Systems


MODEL NUMBER IDENTIFICATION

DT A D - 05 1 2 - C
C - Auxillary Chilled Water Coil
(Air or Water Cooled Units)
DATA TEMP
E - Energy Saver Coil
A--------Air Cooled (Water/Glycol Cooled Units)
W --- Water Cooled
G --- Glycol Cooled Voltage
C --- Chilled Water 2 - 208 or 230 V
4 - 460 V
D - Downflow 5 - 575 V

U ---- Upflow
Phase
1 - Single Phase
Nominal tons
2-5 tons 3 - Three phase

Figure 5 - Data Temp Systems (Single Circuit)

Modular Data Temp Systems


MODEL NUMBER IDENTIFICATION

DT A D - 08 3 2
Voltage
MODULAR 2 - 208 or 230 V
DATA TEMP 4 - 460 V
5 - 575 V

A ---- Air Cooled Phase


W - Water Cooled 3 - Three phase
G - Glycol Cooled
C - Chilled Water

U ---- Upflow
D - Downflow

Nominal tons
8-13 tons

Figure 6 - Modular Data Temp Systems (Single Circuit)

Product Model Number Guide


6
12.04.17
Data Aire Systems (DX)
MODEL NUMBER IDENTIFICATION
DA A D - 20 3 2 -C
C - Auxillary Chilled Water Coil
(Air or Water Cooled Units)

DATA AIRE E - Energy Saver Coil


(Water/Glycol Cooled Units)

A------Air Cooled
Voltage
W - Water Cooled
2 - 208 or 230 V
G - Glycol Cooled
4 - 460 V
5 - 575 V
D - Downflow
U --- Upflow Phase
3 - Three phase

Nominal tons
06 - 30 tons

Figure 7 - Data Aire Systems (DX)

Data Aire Systems (Chilled Water)


MODEL NUMBER IDENTIFICATION
DA C D - 15 3 4
Voltage
2 - 208 or 230 V
DATA AIRE 4 - 460 V
5 - 575 V
C - Chilled Water
Phase
3 - Three phase
D - Downflow
U ---- Upflow

Nominal tons
07 - 50 tons

Figure 8 - Data Aire Systems (Chilled Water)

Product Model Number Guide


12.04.17
7
CEILING UNITS

Mini Ceiling Systems


MODEL NUMBER IDENTIFICATION
DAM A - 01 1 2 - P
P - Package System
DATA AIRE MINI
CEILING SYSTEM CO - Split system with
outdoor condenser
A ------ Air Cooled (DARC)
G --- Glycol Cooled
W --- Water Cooled CO - Split system with
C --- Chilled Water indoor condenser
(DAIC)
Nominal tons
01, 1.5, 02 and 2.5 AO - Split system with
outdoor condensing unit
Phase
(DRCU)
1 - Single Phase
CONDENSER - Condenser coil only, no compressor
CONDENSING UNIT - Condenser coil and compressor
Voltage AI - Split system with
The order write up should have the condenser or condensing unit model number. 2 - 208, 230 or 270 V indoor condensing unit
Refer to applicable condenser or condensing model number identification.
(DAAC)
Example: DATA AIRE MINI, air cooled, 1 ton, 10 - 230 volts, packaged system
DAMA 0112 P

Figure 9 - Mini Ceiling Systems (Single Circuit)

Mini-Plus Ceiling Systems


MODEL NUMBER IDENTIFICATION

DAP A - 2.5 1 2 - E - CO
P - Package System
DATA AIRE MINI-PLUS
CO - Split system with
CEILING SYSTEM outdoor condenser
A ------ Air Cooled (DARC)
G --- Glycol Cooled CI - Split systems with
W -- Water Cooled indoor condenser
C --- Chilled Water (DAIC)

Nominal tons AO - Split system with


outdoor condensing unit
2.5, 03, 04 and 05
(DRCU)
Phase
1 - Single Phase AI - Split system with
3 - Three Phase indoor condensing unit
(DAAC)
Voltage
2 - 208 or 230 V
4 - 460 V C - Auxilary chilled
5 - 575 V water coil
E - Energy Saver
Figure 10 - Mini-Plus Ceiling Systems (Single Circuit)

Product Model Number Guide


8
12.04.17
Large Ceiling Systems
MODEL NUMBER IDENTIFICATION

DAL A - 06 3 2 - E - CO- D
DATA AIRE LCS UNIT D - Dual Compressor
Single or Dual Circuit
S - Single Compressor
A ------ Air Cooled
G --- Glycol Cooled P - Package System
W --- Water Cooled
CO - Split system with
C --- Chilled Water
outdoor condenser
(DARC)
Nominal tons
06, 08, 10 and 13
LCS units are not available in air cooled packaged configuration. AO - Split system with
CONDENSER - Condenser coil only, no compressor
outdoor condensing unit
CONDENSING UNIT - Condenser coil and compressor
Phase (DRCU)
3 - Three Phase
The order write up should have the condenser or condensing unit model number.
Refer to applicable condenser or condensing model number identification. C - Auxilary chilled
Voltage water coil
Example: DATA AIRE LCS UNIT, air cooled, 6 ton, 30 - 230 volts, split system with 2 - 208 or 230 V
outdoor condenser and dual compressors - E - Energy Saver
Evaporator model: DALA 0632 CO D Condenser model: DARC 0632
4 - 460 V
5 - 575 V

Figure 11 - Large Ceiling Systems (Single or Dual Circuit)

Product Model Number Guide


12.04.17
9
HEAT EXCHANGERS

Outdoor Remote Condensers (RC)


MODEL NUMBER IDENTIFICATION
GH RC - 035 3 4 - LD
* Only on DA Series for for LD
PSC fans - DA
LD - Low decibel
gForce EC fans - GH
Voltage
2 - 208 or 230 volt
Remote Condenser - RC
4 - 460 volt

Nominal tons - Data Aire


Phase
Kilowatts - gForce
1 - Single Phase
3 - Three Phase

Figure 12 - Outdoor Remote Condensers (RC)

Outdoor Condensing Units (CU)


MODEL NUMBER IDENTIFICATION
DR CU - 05 1 2
Voltage
PSC fans - DA 2 - 208 or 230 volt
gForce EC fans - GH 4 - 460 volt

CU - Remote Condensing Unit Phase


1 - Single Phase
HCU - Rejection Remote Condensing Unit
3 - Three Phase
Nominal tons - Data Aire
Kilowatts - gForce

Figure 13 - Outdoor Condensing Units (CU)

Model
DARC 07xx-PB
DARC 09xx-PB DARC 07xx-PB to DARC 09xx-PB are single fan units.

DARC 11xx-PB
DARC 15xx-PB
DARC 17xx-PB
DARC 21xx-PB DARC 11xx-PB to DARC 28xx-PB are dual fan units.
DARC 24xx-PB
DARC 28xx-PB

Figure 14 - Indoor “Piggy-Back” Remote Condenser (RC+PB)

Product Model Number Guide


10
12.04.17
Outdoor Fluid Coolers (Dry Coolers)(FC)
MODEL NUMBER IDENTIFICATION
DA FC - 06 1 2 - LD

PSC fans - DA LD - Low decibel


gForce EC fans - GH PB - Indoor Centrifugal

FC - Fluid Cooler
Voltage
2 - 208 or 230 volt
Nominal tons
4 - 460 volt

Phase
1 - Single Phase
3 - Three Phase

Figure 15 - Outdoor Fluid Coolers (Dry Coolers) (FC)

Model
• DAFC-06-PB

• DAFC-07-PB

• DAFC -09-PB

• DAFC -11-PB

• DAFC -15-PB

• DAFC -17-PB

• DAFC -21-PB

• DAFC-28-PB

Figure 16 - Indoor “Piggy-Back” Fluid Cooler (FC+PB) (Dry Coolers)

Product Model Number Guide


12.04.17
11
SPECIALTY UNITS
Data Cool Systems
MODEL NUMBER IDENTIFICATION
DC A U - 02 1 2 - AO
AO - Split system with
outdoor condensing unit
DATA COOL
(DRCU)
Single Circuit

A ------ Air Cooled AI - Split system with


G --- Glycol Cooled indoor condensing unit
W --- Water Cooled (DAAC)
C --- Chilled Water
Voltage
2 - 208, 230 volt
U - Upflow
Phase
1 - Single Phase

Nominal tons
02 and 03

Figure 17 - Data Cool Systems (Single Circuit)

Shelf Systems
MODEL NUMBER IDENTIFICATION

DAS A - 02 1 2 - CO
P - Package System
DATA AIRE Fluid cooler identification
SHELF SYSTEM may be required for glycol
Single Circuit cooled units. (DAFC)

A ------ Air Cooled CO - Split system with


outdoor condenser
G --- Glycol Cooled
(DARC)
W --- Water Cooled
C --- Chilled Water CI - Split systems with
indoor condenser
SHELF SYSTEMS units are not available in air cooled packaged configuration.
Nominal tons (DAIC)
02, 03 and 04
CONDENSER - Condenser coil only, no compressor
CONDENSING UNIT - Condenser coil and compressor AO - Split system with
Phase
1 - Single Phase outdoor condensing unit
The order write up should have the condenser or condensing unit model (DRCU)
number. Refer to applicable condenser or condensing model number 3 - Three Phase
identification. AI - Split system with
Voltage
Example: DATA AIRE SHELF SYSTEM, air cooled, 2 ton, 10 - 230 volts, split 2 - 208 or 230 volt indoor condensing unit
system with outdoor condenser 4 - 460 volt (DAAC)
Evaporator model: DASA 0212 CO Condenser model: DARC 0312
5 - 575 volt

Figure 18 - Shelf Systems (Single Circuit)

Product Model Number Guide


12
12.04.17