http://www.adsequip.

com/

Installation Manual
of AJ15 US Dental Chair

P/N:8021151 Version:A Date:2017-08-01
Installation manual of AJ15 US dental chair

Copyrights

ADS makes no warranty of any kind with regard to this


material , including but not limited to, the implied warranties
of merchantability and fitness for a particular purpose. ADS
shall not be held liable for any errors contained herein or any
consequential or other damages concerning furnishing,
performance or use of this material. The information in this
document is subject to change without notice . If you find
any problems in the documentation, please report them to us
in writing. ADS does not warrant that this document is error-
free.
No part of this document may be copied, reproduced, altered,
or transmitted in any form or by any means, electronic or
mechanical, including photocopying, recording, or by any
information storage and retrieval system, without prior
written permission from ADS.
The document is intended to be used in conjunction with the
equipment.

Comments and feedback


Please contact us if you have any feedback and opinions on
this document:
Add: 12240 Eastend Ave,Chino,CA 91710
Tel: (626) 620 0456
E-mail : [email protected]
http://www.adsequip.com/
Product service
If you want to get service information, please contact the
local dealer authorized by ADS company.
Technical support tel: 800 488 9708
Installation manual of AJ15 US dental chair

CONTENTS
1 Introduction……………………………………………………………1
1.1 Products information…………………………………………1
1.2 Symbols explanation……….…………………………………1
2 Composition……………………………………..………………………3
3 Parameters………………..........………………………………………4
3.1 Specifications……………………………………………………4
3.2 Si ze . …………………………………………………………4
4 Preparations………..……………………………………………………5
4.1 Attentions...…...……………………………………………………5
4.2 Tools recommended………………..…………….…………….6
4.3 Installation requirements………………………………………..7
5 Installation…………………………………………………………7
5.1 Place the chair ...………………………………………………7
5.2 Fix the chair………………………………………………………8
5.3 Install the backrest………………………………………………9
5.4 Install the headrest ……………………………………………10
5.5 Install backrest upholstery……...………………………………11
5.6 Install seat upholstery………………………………………12
6 Operations……………………………………………………………13
6.1 Power………….………………………………………………13
6.2 Chair positioning…………………………………………14
6.2.1 Operate by foot control………………………………………14
6.2.2 Control panel and function set …………………………………14
6.2.3 System state ……………………………………………………15
6.2.4 Initial settings of the chair……..................................……15
6.2.5 Initial setting description………………...………...…………15
6.2.6 Chair positions description……………………………………18
6.3 Dual articulating headrest……………………………………20
6.4 Armrest …………………………………………………………21
Installation manual of AJ15 US dental chair

6.5 Chair rotation……………………………………………………22


7 Regulation & maintenance…………………………………………23
7.1 Remove t h e u p h o l s t e r y ……………. ……………………2 3
8 Reserved lines ………………………………………………………25
9 Maintenance & sterilization instructions ……………………………26
10 Connecting diagrams………...........…………………………………27
Installation manual of AJ15 US dental chair

1 Introduction

1.1 Product information


• Name:Dental chair

• Model:AJ15US
• Working conditions:
① Ambient temperature:5 ℃~40 ℃;
② Relative humidity:≤ 80%;
③ Air pressure:86 kPa~106 kPa;
④ Nominal voltage:AC110 V±22 V;
⑤ Nominal frequency:50 Hz±1 Hz;

1.2 Symbols explanation


Table 1

Symbol Explanation

Manufacturer EU representative

Producing date Serial number.

 Place with care Keep dry

1 P/N:8021151
Installation manual of AJ15 US dental chair

Symbol Explanation

Refer to attached document Notice

Avoid electric shock Backrest Down

Ground protection Backrest Up

0
Original position Chair Down

P Chair Up
Set

Spitting position Program Chair Position 1

Program Chair Position 2 Program Chair Position 3

2 P/N:8021151
Installation manual of AJ15 US dental chair

2 Composition
AJ15US dental chair (figure 1)combined with new design concepts ,
provide a good balance for usability ,simplicity and comfortability.

Figure 1 AJ15 US Dental Chair

1 2 3 4

5 6 7 8 9

Item Component Item Component

1 Headrest 6 Armrest button

2 Backrest 7 Touch pad control panel

3 Armrest 8 Lifting arm

4 Seat 9 Junction box

5 Foot control

3 P/N:8021151
Installation manual of AJ15 US dental chair

3 Parameters
3.1 Specifications
Load bearing
Patient bearing:Max 300 pounds(135kg)

Tip: Specifications are subject to change without notice.

3.2 Size (unit: inches)

4 P/N:8021151
Installation manual of AJ15 US dental chair

4 Preparations
4.1 Attentions
Before install the unit, you should:

• Clear all the debris in the room ,and clean the floor thoroughly.
• Apply two manually operated valves for the air and water source.
• Exhaust the dirty water and air before connecting.
• May have no necessity to use all the component described in this document when
installing. Components should be evaluated before installation.

Before install the unit, please read the manual carefully:


• Input voltage AC110 V ,50/60 Hz.
• Make sure the dental unit is in good grounding.
• All the electrical components and connections should be made by an authorized
technician.
• Only fuse and accessories recognized by ADS technician can be used.
• his device should not operate in the environment of high temperature, high
humidity, vibration ,flammability, unbalance, or dusty.
• Only the authorized spare parts can be used in this device.
• This dental unit should not come into contact with any object in its operational
range of movement.
• This device can not be used in the environment of strong magnetic,
electromagnetic.

Leather maintenance:
• No organic solvent or alkaline detergent (such as: gasoline、alcohol ,etc.), or the
leather will crack, be smelly or fade;
• No exposure, keep the room in good ventilation(exposure can cause the leather
crack,bad ventilation lead to go mouldy);
• Mention the patient to remove edged tools(like keys)before operation,to avoid
scratch the leather.

5 P/N:8021151
Installation manual of AJ15 US dental chair

4.2 Tools recommended

The tools and instruments need to prepare before installation.

Electrical drill Pincers

Hammer Scissors

Leveling Flat-bladed
instrument Screw driver

Phillip screw Allen wrench


driver

Hexagon
Spanner socket
wrench

6 P/N:8021151
Installation manual of AJ15 US dental chair

4.3 Installation requirements Size(unit : inches)

Note:Sizes above are the minimun that required.

5 Installation
5.1 Place the chair

1. Remove all debris and cardboards Holds


around the chair.
2. Hold the handrail and the front of the
frame, uplift the chair and place the
chair on the right place.
3. Remove bunding belt and packages.

7 P/N:8021151
Installation manual of AJ15 US dental chair

5.2 Fix the chair


Attentions:
1.The chair must be fixed on the floor for ensuring stability,
for it can be seriously damaged by wrong fixation.
2.Check out the material of the floor on the installing place.
Please contact the authorized contractor to thickening the
floor if its thickness is less than 82 mm.

1、Power on and activate the unit.


2、Step the button on foot control ,
raise the unit.
3、Unit switched off and power
disconnected.

4、Remove the cover and mark the installing position , then move the unit away.

Drill on the marked position, press the explosive bolt, then return the unit to its

position and tighten the screw.

8 P/N:8021151
Installation manual of AJ15 US dental chair

5.3 Install the backrest

Figure 2

2
3

1 Metal backrest

2 M6*20 Hexagon socket cuntersunk screw

3 M6 External teeth lock washer

4 Head of the push rod

5 Push rod

Pass the M6*20 cuntersunk screws through the M6 lock washer , then
fix the push rod head on the backrest by the M6 cuntersunk screws.

9 P/N:8021151
Installation manual of AJ15 US dental chair

5.4 Install the headrest

Figure 3

Damping adjustment nut

Install the headrest


1. Push the headrest glidebar into the slot of the backrest.
2. Adjust the nut to get proper damping force.
3.Install the upholstery onto the bottom plate.

10 P/N:8021151
Installation manual of AJ15 US dental chair

5.5 Install backrest upholstery

Figure 4

1 2 3

1 Metal backrest

2 Fixing shaft

3 Backrest upholstery

When installing the upholstery, you should put the upholstery on


the backrest with the shaft head pass through corresponding
keyholes of the upholstery, then push the upholstery in force till it’s
fixed.

11 P/N:8021151
Installation manual of AJ15 US dental chair

5.6 Install the seat upholstery


Figure5 A B

A Fixing bracket

B Chair frame

C M5*16 Cross recessed pan head bolt group

Install the seat upholstery


Put the upholstery onto the chair frame, lock the bracket and the rear end of the chair
frame together, and tighten the two screws on the front end of the chair frame.

12 P/N:8021151
Installation manual of AJ15 US dental chair

6 Operations

6.1 Power
The power switch of the power box controls power supplying of the

dental chair and its delivery system.


Switch on and you can get the power,switch off for not using in a long
term, or before maintenance .

Figure 6

13 P/N:8021151
Installation manual of AJ15 US dental chair

6.2 Chair positioning


You can operate the chair manually or by foot control.

6.2.1 Operate by foot control


Raise or low the chair by pressing base up/down button , step on the
up/ down arrow on the foot control till the chair is in desired position.
Move the backrest by pressing backrest up/down button , step on the
left/right arrow till the backrest is in desired position .

Figure 7

0 Original position

Program Chair
1 Position 1

Program Chair
2 Position 2

P Set

LP Spitting position

Backrest down

Backrest up

Chair up

Chair down

14 P/N:8021151
Installation manual of AJ15 US dental chair

6.2.2 Control panel and function set

Figure 8 0 Original position

Program Chair
Position 1

Program Chair
Position 2

Program Chair
Position 3

P Set

LP Spitting position

Backrest down

Backrest up

Chair up

Chair down

6.2.3 System state


If the indicator light is bright on the control panel, it indicating
that the system is normal ,and you can operate normally.

15 P/N:8021151
Installation manual of AJ15 US dental chair

6.2.4 Initial settings of the chair

Electric motor system initial settings specification:

Press the “O” button on the main control panel of dentist unit to descend the
chair motor till the lower limit switch is triggered, raise the backrest motor till
the higher limit switch is triggered. System initialize automatically ,it can be
normally performed after initialization finished .

Caution: Electric motor system shall have the initial settings


in following situations.
 .First installation.
.Motor replacement.
 .Main board replacement.
 .Limit switch readjustment or replacement.
 .Abnormal movement .

Hydraulic system initial settings specification :

1、Press “SET” button about 12 second until the buzzer sound 2 short
beeps(the indicator flashes twice and then illuminates),enter original setup
status; press P1,the buzzer sound 1short beep( P light off),escape setup
status. This steep eliminates the original stroke parameters.
2、Press “SET” button about 12 second until the buzzer sound 2 short beeps,
(the indicator flashes twice and then illuminates),enter initial setup status ,
press the four moving chair button to make backrest up and press “R”, and
then press the four moving chair button again to make chair up to the highest
and the backrest is on the lowest. At this time, press “LP” and then finish the
setting.
16 P/N:8021151
Installation manual of AJ15 US dental chair

Caution:Hydraulic system shall have the initial settings


in following situations:
First installation or replacement of mainboard .
Insert/replace/repair any position feedback potentiometer or
wiring.
Reset or replace the limit switch..
Reset the motion range of the chair.(Disabled to move or cannot move
to desired position.)

Attention:
When setting up the system,do not extend the maximum range of the
cylinder t prevent the hydraulic pump from not working properly.

6.2.5 Initial setting description

Process P or or P
• Move the chair and backrest to the working position, and adjust dental light
to the desired condition ( On or Off), press the “P” button(3s),the
indicator light is on (beep 1 time),( loose button so as not to enter the
original setting state),enters the setup procedure.
• Press the “P1” button ,and then press the “P “button one time
again,(beep1-2times),setup finished and escape the setup procedure.
• P2, P3 position setup are same step as the P1.

17 P/N:8021151
Installation manual of AJ15 US dental chair

6.2.6 Chair positions description


a. Backrest Up
Press this button continuously and the backrest will move upwards. When the
backrest reach the desired position, stop pressing the button and the backrest will
stop immediately.

NOTE: If you press the button continuously, when the chair backrest
reach the limit position, it will automatically stop the movement.

b. Backrest Down
Press this button continuously and the backrest will move downpwards. When the
backrest reach the desired position, stop pressing the button and the backrest will
stop immediately.

NOTE: If you press the button continuously, when the chair backrest
reach the limit position, it will automatically stop the movement.

c. Chair up
Press this button continuously and the chair will move upwards. When the backrest
reach the desired position, stop pressing the button and the backrest will stop
immediately.

NOTE: If you press the button continuously, when the chair backrest
reach the limit position, it will automatically stop the movement.

d. Chair down
Press this button continuously and the chair will move downwards. When the backrest
reach the desired position, stop pressing the button and the backrest will stop
immediately.

NOTE: If you press the button continuously, when the chair backrest
reach the limit position, it will automatically stop the movement.

18 P/N:8021151
Installation manual of AJ15 US dental chair

e. Original position 0
Pr e ss t h e b ut t o n, t h e c h a i r a n d ba c kr e st wi l l m o v e t o t h e o r i g i n a l p o s i t i o n
automatically(Original position : backrest highest , the chair lowest) and light off . Press
this button again , the chair returns to former position and light on. The chair shall stop at
a new position by halfway stop.

f. Spitting button
Press the button, the chair and backrest will move to spitting position
automatically(Spitting position : backrest highest , the chair is still) and light off . Press
this button again , the chair returns to former position and light on. The chair shall stop at
a new position by halfway stop.

19 P/N:8021151
Installation manual of AJ15 US dental chair

6.3 Dual articulating headrest

Figure 9 Headrest adjustment

A Headrest
B Quick-release button
C Glidebar

NOTE:
Please fix the headrest after adjustment to avoid patient’s head not
being settled.

Figure 10 Fix the headrest for a wheelchair

20 P/N:8021151
Installation manual of AJ15 US dental chair

Fix the headrest for a wheelchair:


1. Backrest of the dental chair is fully raised.
2. After reposition the headrest ,raise or descend the chair to adjust heights.

Patient's position should also be adjusted to put the wheelchair and


dental chair back to back together.
3. Make sure the wheelchair is locked.

6.4 Armrest
The armrest is easy to operate ,which provides convenience to users .
Press the button you can rotate the armrest forward or backward .

Figure11 Armrest
positioning

Button

21 P/N:8021151
Installation manual of AJ15 US dental chair

6.5 Chair rotation

Figure 13 Chair rotation

Tighten
Loosen

Pull the handle behind the chair to rotate:


1.Pull the handle rightwards to loosen the
brake;
2.Push the handle leftwards to tighten the
brake when the chair gets to desired angle.

Figure 14 Handle adjustment

You should adjust the tension of handle if


the chair can not be fixed or the handle
is hard to move.
1. Loosen the set screw by an Allen
wrench ;
2. Rotate the handle to adjust tension:
clockwise to tighten,counterclockwise
to loosen ;
3. Tighten the screw after adjustment.

22 P/N:8021151
Installation manual of AJ15 US dental chair

7 Regulation & maintenance


7.1 Remove the upholstery

The special design of upholstery is easy to remove and replace .They are
installed on backrest, seat and headrest of the chair .

Backrest upholstery
To take off the upholstery from backrest ,you should hold the bottom
edge of gasket firmly and lift it up (1 inch or 25 mm) ,then lift the
upholstery from the backrest of the chair ( Figure15).
To reinstall the upholstery,you can put the keyhole of gasket on nail
head, then push till the gasket is fixed.

Figure 15 Remove the upholstery

23 P/N:8021151
Installation manual of AJ15 US dental chair

Seat upholstery
Loose the screw at the front end of the upholstery, push the upholstery
forward,then remove the seat upholstery.

Figure 16 Remove the seat upholstery

24 P/N:8021151
Installation manual of AJ15 US dental chair

8 Reserved lines
Swing Type

A B C

1
A 21
32
43
54
65 1. 1/8" white , reserved for dentist unit
76
87 2. 1/8" brown,reserved for dentist unit
8 3. 1/8" red, reserved for dentist unit
9
10 4. 1/8" orange, reserved for dentist unit
11 5. 1/8" black, reserved for dentist unit
6. 1/8" blue,reserved for dentist unit
12
7. 1/8" yellow,reserved for dentist unit
13 8. 1/8" green,reserved for dentist unit
14
9. 1/4" black,reserved for dentist unit
15
10. 1/4" blue,reserved for dentist unit
11. 1/4" red,reserved for dentist unit
C 12. Control wire for delivery head
16 13. 24V, 7 core power cord for delivery head
14. 24V power cord for dental light
17 15. Ground wire for delivery head
16. 1/4" green, reservd for assistant's control
18
17. 1/4" yellow, reservd for assistant's control
18. Control wire for assistant control
B. Drainage pipe

25 P/N:8021442
Installation manual of AJ16US dental chair

Lines
Lines offorOTP
OTP version
version

12. Control wire for delivery head

13. 24V, 7 core power cord for delivery head

14. 24V power cord for dental light


15. Ground wire for delivery head

9 Maintenance & sterilization instructions


Touch surface & transfer surface
Touch surface refers to the surface area that need contact in dental treatment while can
be potential cross contamination points.
Transfer surface refers to the surface area that contaminated from contacting with the
instruments or other inactive object.
ADS company recommends isolating protection for all applicable touch surfaces and
transfer surfaces. The partition used must be a plastic film approved the Food & Drug
Administration. The plastic films should be taken off and discarded after the
treatment of each patient.
26 P/N:8021442
Installation manual of AJ15 US dental chair

9 Connecting diagrams
Connecting diagram(Electric system)

27 P/N:8021151
Installation manual of AJ15 US dental chair

Connecting diagram (Hydraulic system)

28 P/N:8021151
We reserve the right to make any alterations which may be due to
technical improvements.

Ajax Dental System Inc.

Add: 13900 Sycamore Way, Chino, CA 91710


Tel: (626) 620 0456
E-mail: [email protected]
http://www.adsequip.com/

You might also like