Data Sheet 2BH1 840: Side Channel Blower

The data sheet provides performance curves and specifications for the G-BH1 Side Channel Blower. The blower can be used for both vacuum and pressure applications over its total performance curve range from 50-150cfm and 20-160 inches of water. It has a temperature rise of under 100°F, maximum power consumption of under 20HP, and sound level under 80dB. The blower has IP55 protection and insulation class F.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
68 views2 pages

Data Sheet 2BH1 840: Side Channel Blower

The data sheet provides performance curves and specifications for the G-BH1 Side Channel Blower. The blower can be used for both vacuum and pressure applications over its total performance curve range from 50-150cfm and 20-160 inches of water. It has a temperature rise of under 100°F, maximum power consumption of under 20HP, and sound level under 80dB. The blower has IP55 protection and insulation class F.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

G-BH1

Data sheet 2BH1 840


Side channel blower

Performance curves

Vacuum operation (acfm) Pressure operation (scfm)

750 750
50 Hz 50 Hz
60 Hz 60 Hz
600 600
1 1
[m³/h]
[cfm]

450 450
2
2
. 1
Suction capacity V

300 300
1

150 2 2 150

0 0
160 140 120 100 80 60 40 20 000 20 40 60 80 100 120 140 160

Vacuum ∆p [inch H
Total pressure difference Dp H2O]
2O] Pressure
25 25
2

20 2 20
[HP]

2
15 15
1 1
2
Power consumption

10 10
1 1
P at pump shaft

5 5

0 0
160 140 120 100 80 60 40 20 000 20 40 60 80 100 120 140 160

Vacuum ∆p [inch H
Total pressure difference Dp 2O]
H2O] Pressure
250 250

200 200

2 2
150 2 150
∆T [F]

100 1 2 100
Temperature rise
of conveyed air

1
50 50
1
1
0 0
160 140 120 100 80 60 40 20 00
00 20 40 60 80 100 120 140 160

Vacuum ∆p [inch H
Total pressure difference Dp 2O]
H2O] Pressure

The performance curves are based on air at a temperature of 59 F and an Every G-BH blower can be used either for vacuum or pressure in continuous
atmospheric pressure of 29.92 inch Hg with a tolerance of ± 10 %. The total operation over the total performance curve range. The standard motors have a
Suction capacity relates to inlet conditions. Pressure capacity relates to protection category of IP 55 and insulation class F. These blowers are UL and
atmospheric conditions. For other conditions please contact Elmo Rietschle. CSA approved.

 Gardner Denver Deutschland GmbH Print date: 9/30/2015 Technical data sheet - Edition 09/2015 US
Selection and ordering data
Type 2BH1 840
No. Fre- Rated Max. differential Sound Weight Order No.
quency pressure 2) pressure Approx.
Voltage 1) Current Power Vacuum Pressure level 3)
Hz V A HP dB(A) ibs
3~ 50/60 Hz, IP55, Insulation material class F, UL 1450 and CNA/CSA 22.2 No 68-09 (certificate number E225239)
50 200-240 ∆ / 345-415 Y 29.0 ∆ / 16.7 Y 10.06 -80 72 74
1 412 2BH1840-7JH26
60 220-275 ∆ / 380-480 Y 30.0 ∆ / 17.3 Y 11.53 -60 48 78
50 200-240 ∆ / 345-415 Y 48.5 ∆ / 28 Y 14.75 -112 149 74
2 448 2BH1840-7JH36
60 220-275 ∆ / 380-480 Y 50.2 ∆ / 29 Y 16.90 -124 141 78
3~ 50/60 Hz, IP55, Insulation material class F, UL 1450 and CNA/CSA 22.2 No 68-09 (certificate number E225239)
50 500 ∆ 13.0 ∆ 10.06 -80 72 74
1 412 2BH1840-7JC25
60 575 ∆ 13.6 ∆ 11.53 -60 48 78
50 500 ∆ 20.4 ∆ 14.75 -112 149 74
2 448 2BH1840-7JC35
60 575 ∆ 20.4 ∆ 16.90 -124 141 78

1) In case of variable frequency drive operation the standard motor insulation system is suitable for VFD input voltages up to 460 V.

2) Relief valves available for limiting differential pressure.

3) Surface sound pressure levels are according to EN ISO 3744, measured with an equivalent unit at a distance of 1 m. The pump is throttled to an average suction pressure, with
piping connected, but no relief valves fitted, tolerance ±3 dB (A).

All G-BH blowers conform to the 2006/42/EC (machinery) and 2006/95/EC (low voltage) directives and the EN 60034-1 norm “Rotating electrical machines”.

The motors comply with EN 60 034-1 / -2 / -30 (IEC 60034) and thermal class F.
For three phase motors tolerances are +/-10% for fixed voltage motors and +/-5% for voltage range motors. Single phase machines are designed with a +/- 5% tolerance.
The frequency tolerance is +/- 2 % maximum.

Motor for alternate voltages


Voltage range Fixed voltage VFD
60 Hz
50 Hz 60 Hz 50 Hz 60 Hz 87 Hz 2BH1840-7. □ . □
∆ Y
3~
185 - 225 V ∆ / 320 - 390 V Y 200 - 240 V ∆ / 345 - 415 V Y • • H 1
200 - 240 V ∆ / 345 - 415 V Y 220 - 275 V ∆ / 380 - 480 V Y 380 V ∆ • • H 6
345 - 415 V ∆ / 600 - 720 V Y 380 - 480 V ∆ / 660 - 720 V Y • H 7
500 V Y 575 V Y • C 3
500 V ∆ 575 V ∆ • C 5
5)
3~ 3~
180 - 240 V ∆ / 310 - 415 V Y 200 - 275 V ∆ / 345 - 480 V Y 200 V ∆ / 345 V Y 230 V ∆ / 400 V Y • • P 1
450 - 550 V Y 520 - 600 V Y 500 V Y 575 V Y • P 3
450 - 550 V ∆ 520 - 600 V ∆ 500 V ∆ 575 V ∆ • P 5
200 - 260 V ∆ / 350 - 450 V Y 230 - 290 V ∆ / 400 - 500 V Y 230 V ∆ / 400 V Y 265 V ∆ / 460 V Y 400 V ∆ • • P 6
350 - 450 V ∆ / 610 - 725 V Y 400 - 500 V ∆ / 690 - 725 V Y 400 V ∆ / 690 V Y 460 V ∆ • P 7

5) Performance can differ if IE2 motors are used. Please refer to corresponding data sheets.

Changes in particular of the quoted performance curve, data and weights may occur without prior notice. The data given do not constitute an obligation from our side to deliver as shown.

Elmo Rietschle is a brand of Gardner Denver Gardner Denver Deutschland GmbH Gardner Denver, Inc.
Industriestraße 26 1800 Gardner Expressway
97616 Bad Neustadt - Germany Quincy, IL 62305
Tel.: +49 9771 6888-0 Tel: 217-222-5400
Fax: +49 9771 6888-4000 Fax: 217-221-8780
Your Ultimate Source for Vacuum and Pressure www.gd-elmorietschle.com ▪ [email protected]