Quick Program Sheet For DTS 500 Expert.: Programming

1. The document provides instructions for setting dipswitches and programming functions like motor direction, auto close time, and pedestrian mode on a DTS 500 Expert gate controller. 2. It describes running a run time setup after power up to calibrate the gate and set the close limit. 3. Additional sections explain how to program the auto close time, pedestrian opening distance and time, and how to reset to factory defaults or erase transmitter buttons from the onboard receiver.

Uploaded by

Francois Vaaltyn
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
178 views

Quick Program Sheet For DTS 500 Expert.: Programming

1. The document provides instructions for setting dipswitches and programming functions like motor direction, auto close time, and pedestrian mode on a DTS 500 Expert gate controller. 2. It describes running a run time setup after power up to calibrate the gate and set the close limit. 3. Additional sections explain how to program the auto close time, pedestrian opening distance and time, and how to reset to factory defaults or erase transmitter buttons from the onboard receiver.

Uploaded by

Francois Vaaltyn
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Quick program sheet for DTS 500 Expert.

Dipswitch selections to activate a function.


Dipswitch 1 - Set up.
2 - Motor direction. (Closing left OFF, Closing right ON).
3 - Auto close.
4 - Condominium mode.
5 - P.I.R.A.C. mode
6 - Slow down distance change
PROGRAMMING
Run Time Setup (This will automatically happen when triggered after TOTAL power up.)
1) Select and change dipswitch 2 & 6 were applicable.
2) Gate approximately 1metre open.
3) Push and release TEST/SET button.
4) Gate will close, open and close again and stop on close limit.
5) Control card will beep twice to confirm end of run time setup.
NOTE: If gate opens first, dipswitch number 2 is wrongly selected.

Auto close (Default 10 seconds) (Infra red beams must be fitted if auto close is activated).
1) Switch Dipswitch 1 and 3 on.
2) Leave dipswitch 2 were it is but put all other dipswitches OFF.
3) Press & hold TEST/SET button.
4) PCB will Beep (1 Beep = 1 Sec)
5) Release BT/SET button at required auto close time (Max. 4 minutes).
6) Switch Dipswitch 1 and 3 off.
7) Switch Dipswitch 3 back on to activate the auto close.
Pedestrian Opening (Default 1 meter / 10 seconds auto close).
1) Switch Dipswitch 1 and 4 on.
2) Leave dipswitch 2 were it is but put all other dipswitches OFF.
3) Gate should be in closed position.
4) Press & Release TEST/SET Button.
5) Gate will open.
6) Press & release TEST/SET button to stop gate at required pedestrian opening distance.
7) Press & Hold TEST/SET button to program auto close time required.
8) Control card will Beep (1 Beep = 1 Sec)
9) Release TEST/SET button at required pedestrian auto close time (Max. 2 minutes).
10) Switch Dipswitch 1 and 4 off.
11) Gate will close again.
To reset factory default
1) Remove all power.
2) Press and hold TEST/SET button, while holding the TEST/SET button, re-apply power, AC and
DC.
3) With power re-applied, release TEST/SET button.
4) PCB will beep to confirm factory default being restored.
Load setting
To adjust the load, turn the provided load pot to determine the load setting (Minimum, anticlockwise
and Maximum clockwise). The control card will beep 1 - 5 beeps on first trigger.

ON BOARD RECEIVER PROGRAMING


The onboard receiver is designed to work with most rolling code transmitters.

PROGRAMMING TRANSMITTERS PROGRAMMING TRANSMITTERS


FOR FULL OPENING – GATE FOR PEDESTRIAN OPENING -PED

1. Push the GATE button, the RX 1. Push the PED button, the
led will go on. RX led will go on.

2. Push the required button on the 2. Push the required button on the
transmitter, at arms length from transmitter, at arms length from
PCB once, the Rx led will flash. PCB once, the Rx led will flash.
Press the same button again, Press the same button again, and the
and the PCB will emit 3 beeps PCB will emit 3 beeps for a full
for a full Keelog transmitter or Keelog transmitter or 2 beeps for
2 beeps for other transmitters. other transmitters.

3. Repeat Step 1 and 2 for 3. Repeat Step 1 and 2 for


additional transmitters. Up to 31 additional transmitters. Up to 31
transmitters can be programmed transmitters can be programmed as a
as a joint combination between joint combination between
GATE and PED. GATE and PD.

The button used for GATE, CANNOT be used for PED and vice versa.
To erase a button from the receiver, in case of incorrect programming i.e. blue button should be for
GATE and not PED.
Simply push and hold the GATE for 5 seconds, the board will give 1 beep. Then push the button
on the TX you want to erase, the board will give 2 beeps as confirmation. That button is then
erased and can be learned into the correct input.
To master erase:
Push and hold the GATE button, after 5 seconds the board with give 1 beeps. Keep holding for
another 10 seconds then the board will give 2 beeps.
All transmitters will now be erased.
PCB Control card. (Please note, can only connect a low voltage power supply and therefore cannot be modified as a High excess
motor)

NB – When connecting intercoms to the control card (IT and CMN), please ensure that
your
intercom trigger output is potential free (ZERO voltage). If not, a gate relay module
must be fitted.

Important – If beams are fitted, remove the fitted bridge by S/BEAM connected between CMN &
N/C.
If no beams are fitted then a bridge must be fitted between CMN & N/C.
List of audio indications and warnings.
One continuous beep- PCB is damage, replace PCB.
One 1.5 second beep- “Party mode” has been activated.
One 2 second beep - Factory defaults have been set.
One 2 second beep - Beams are incorrectly wired or faulty when
programming the motor. or
Runtime was aborted for whatever reason.
One 3 second beep - Holiday lockout mode has been activated.
One 3 second beep - Gate triggered when motor is in 3 minute overload
lockout.
Two 400 ms beeps - Run time programming (calibrating) has been
successful.
Two 1 second beeps - Pedestrian mode was activated.
or No AC power is present, running battery power
only.
Three 200ms beeps - Battery power is too low, or
Override function is open or faulty.
Four 100ms beeps - Motor is in holiday lockout.
Four 200ms beeps - Check motor/load fuse (25amp).
- Check motor brushes and armature.
- PCB reader not picking up Magnet on motor.
Five 1 second beeps - Holiday lockout mode has been de-activated.
Twenty 100ms beeps - Motor has stalled or overloaded, then check the
following points:
1) Gate pulling force (should not exceed 12.5kg)
2) Load pot is set too low (Turn pot completely
clockwise)
3) Battery voltage under load (12volt) (Not
connected)
4) Gearbox gearwheel.

List of LED indications.


- LED ON when open limit is activated. (gate open).
- LED OFF when close limit is activated. (gate closed).
- LED flashing SLOW (1 sec. on/1 sec. off) (gate is in motion).
- LED flashes 2 long/3 short continuously (gate is stopped midway).
- LED flashes fast (250ms on/250ms off) continuously. (gate in overload).
- LED flashes 3 fast flashes every 1.5 seconds. (battery low, <11VDC).
- LED flashes 1 slow/2 fast continuously. (NO 220 VAC power present).
FOR SAFETY REASONS.
Infra-red beams are recommended for
all gate motor installations.