This document discusses changes to lighting design standards and calculation methods from CIE 30.2 to CIE 140. All references to CIE 30.2 in lighting standards have been replaced with CIE 140. Commercially available software must now be used to perform lighting calculations according to CIE 140, replacing obsolete programs like SABS 098. Methods of measuring and scanning light distributions have also changed to comply with CIE 140 recommendations.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
377 views1 page
Changing From CIE30.2 To CIE140
This document discusses changes to lighting design standards and calculation methods from CIE 30.2 to CIE 140. All references to CIE 30.2 in lighting standards have been replaced with CIE 140. Commercially available software must now be used to perform lighting calculations according to CIE 140, replacing obsolete programs like SABS 098. Methods of measuring and scanning light distributions have also changed to comply with CIE 140 recommendations.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
LIGHTING DESIGN
& APPLICATION
T he calculation methods in CIE 140 bring about several
improvements resulting from the experience that has been gained over the past 25 years in street lighting.
Changing from CIE 30.2 to CIE 140
S A N S 1 0 0 9 8 - 1 : 1 9 9 0 : “ Pu b l i c Information from Beka Lighting Part 1: The lighting of public thoroughfares”, and ARP035:2002: “Guidelines for the installation and maintenance of street lighting”, have can be verified by comparison to the which contributes to the assurance that been revised so that the street lighting source data from the SABS. the average luminance as observed by calculation methods in the new CIE References to encrypted luminaire data a motorist is correct and that the street files that are to be submitted with tenders lighting installation will promote safety 140: “Road lighting calculations” are have been replaced by other electronic and comfort. used instead of the now obsolete CIE 30.2: “Calculation and measurement data files that have to be submitted Spacing between poles to achieve of luminance and illuminance in road together with the SABS source data in certain lighting levels will now generally lighting”. electronic format. be shorter with a corresponding increase References to encrypted data files which in the “per-kilometer” cost of street Scope of amendments lighting. are to be created from the intensity SANS 10098-1 tables have been replaced by other The traditional software, such as the All references to CIE 30.2 have been data files that are to be converted by SABS 098 program that has been used replaced with CIE 140. the SABS luminaire supplier, from the since 1992 to carry out street lighting source intensity tables. calculations is now obsolete and must The reference to the computer programs be replaced by commercial software that listed in CIE 30.2 have been replaced Street lighting software will do calculations as per CIE 140. with a reference to Windows-based Although there is no reference to the Beka will host a street lighting road commercially available computer SABS 098 program in SANS 10098-1, show in the first quarter of 2008 where, programs which do calculations it has been the benchmark of street among other subjects, the changes from according to CIE 140. lighting designs with computer software, CIE 30.2 to CIE 140 will be discussed All design methods and design criteria as it is referred to in ARP035. Because in detail. are to be based on that of CIE 140. of the revisions to ARP035, this program Contact Murray Cronjé, Beka, The photo goniometer laboratory at the will no longer be suitable to do street Tel 011 238-0000, SABS will have to change its method of lighting calculations; hence all users [email protected] D scanning the photometric distribution will now have to switch to some type of of street lights to comply with the commercial software to do calculations. recommendations of CIE 140. There is a wide choice of such programs: ARP035 Relux, Dialux, Ulysse, AGI32, Cophos and Lighting Reality, among others. The All references to the SABS 098 road only proviso is that the software must be lighting computer program have been able to carry out calculations according replaced by references to Windows-based to the CIE 140 method, and that the commercially available road lighting results produced by the program must programs that can do calculations in have been tested by an independent terms of CIE 140. authority to confirm that the calculations The encrypted data files that were used are accurate. only in the SABS 098 computer program have been replaced by other data files Conclusion in a suitable format for the commercially The method of doing calculations as per available Windows-based programs. CIE 30.2 is now obsolete and has been The authenticity of these other data files superseded by the methods of CIE 140,