XX-00220 XX-00221/00443: Contact Probe For Fixtureless Tester APT-94XX Series

The document provides specifications for various contact probe models for Fixtureless Tester APT-94XX Series, including tip style, material, maximum stroke, and spring pressure. It also lists minimum probe pitch and target pad size by probe type, and probe pressure at different compression depths for specific probe models.

Uploaded by

Hola Sanchez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
244 views

XX-00220 XX-00221/00443: Contact Probe For Fixtureless Tester APT-94XX Series

The document provides specifications for various contact probe models for Fixtureless Tester APT-94XX Series, including tip style, material, maximum stroke, and spring pressure. It also lists minimum probe pitch and target pad size by probe type, and probe pressure at different compression depths for specific probe models.

Uploaded by

Hola Sanchez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Contact probe for Fixtureless Tester APT-94XX Series

Model No. Tip style Material Max. stroke Spring pressure


XX-00220 Chisel SK-4
XX-00221 Needle SKH51
XX-00222 4 point crown SK-4
8 mm Refer to below
XX-00332 4 point crown SK-4
XX-00377 4 point crown SK-4
XX-00443 Needle SKH51

17 28.5
52.5
49

45

5
1.37 1.25 0.22

XX-00220 XX-00221/00443
60

60

5
0.13
0.18
XX-00222/00377 XX-00332

Spring Pressure

2.5

1.5
(N)

0.5

0
0 1 2 3 4 5 6 7 8
XX-00220/00221/00222/00332 (mm)
XX-00377/00443

TAKAYA CORP.
94XX Minimum Probe Pitch and Target Pad Size by Probe Type

The minimum contact probe pitch (center-to-center spacing):


XX-00220 – Chisel probe tip:
1250um (1.25mm / 49.2mil / 0.0492in)

XX-00221 – Needle probe tip:


200um (0.2mm / 7.87mil / 0.0079in)

XX-00222 – 4-point Crown probe tip:


300um (0.3mm / 11.81mil / 0.0118in)

XX-00377 – 4-point Crown probe tip:


300um (0.3mm / 11.81mil / 0.0118in)

The minimum probe contact pad size (target):


XX-00220 - Chisel probe tip:
140um (0.14mm / 5.51mil / 0.0055in) – 160um (0.16mm / 6.3mil/ 0.0063in)

XX-00221 - Needle probe tip:


120um (0.12mm / 4.72mil / 0.0047in)

XX-00222 - 4-point Crown probe tip:


140um (0.14mm / 5.51mil / 0.0055in) – 160um (0.16mm / 6.3mil/ 0.0063in)

XX-00377 - 4-point Crown probe tip:


140um (0.14mm / 5.51mil / 0.0055in) – 160um (0.16mm / 6.3mil/ 0.0063in)
94XX Probe Pressure by Probe Type & compression depth

1mm 2mm 3mm 4mm


XX-00220 115gf 130gf 145gf 160gf
XX-00221 (1.13N / (1.27N / (1.42N / (1.57N /
XX-00222 4ozf) 4.59ozf) 5.1ozf) 5.6ozf)

53gf 68gf 83gf 99gf


XX-00377 (0.52N / (0.67N / (0.81N / (0.97N /
1.87ozf) 2.40ozf) 2.93ozf) 3.49ozf)