Maxfort Multispeciality Hospital Aligarh - 35 KLD ESTP
Maxfort Multispeciality Hospital Aligarh - 35 KLD ESTP
0045
Dear Sir,
Thanks for the enquiry forwarded to us for a 35 KLD ESTP Plant for Hospital waste water.
Please find enclosed the offer for the proposed Effluent Cum Sewage Treatment Plant. Please note that
the offer is for only for electromechanical components. The proposed ESTP is of continuous process
type.
Please note that the sizes and power requirements of the units are rough estimates and may vary
at the time of final designing depending upon the space provided for the ESTP.
We hope you shall find the same in order and in line to your requirement.
Thanking You,
Yours Sincerely
Ambar Sharma
Awetech Works
ANNEXURE DETAILS
4 ESTP - LAYOUT
6.5 - 9
pH 6-8
PROCESS DESCRIPTION
Bar Screen :- The raw Sewage & Effluent is separately passed through a manually cleaned Bar Screen 1 and
Bar Screen 2. The Bar Screen has narrow slits that capture the material, while letting the wastewater pass through to
the next stage of treatment. The debris is removed in this stage of treatment so that it does not interfere with the
other stages further downstream.
Oil & Grease Tank :- The Sewage is next passed to an oil separator. The Oil is separated from the aqueous
phase in the Oil Separator provided with the Oil collector so that the floating oil could be collected separately in a
container. The sewage is then collected in an Sewage Equalization Tank.
Equalization Tank :- The purpose of Equalization tanks is to equalize the flow rate and the concentration of the
wastewater. The Equalization tanks have been provided with an aeration grid for mixing and preventing the sewage
from becoming septic.
Sewage Transfer Pump :- feed Sewage water from Equalization tank to chemical reactor for coagulation &
flocculation.
Chemical Reactor :- in chemical reactor we add coagulant like alum for neutralize the surface negatively charged
particles that combined the smaller particles in micro flocs is called coagulation after coagulation. We add flocculent
like pac that convert micro flocs to macro flocs that is called flocculation. Effluent pass through the primary clarifier
for next stage of treatment.
Primary Clarifier :- in this stage of treatment the effluent water. Here the velocity of the waste water is slowed to
allow for the chemical sludge to clump together and settle to the bottom through pvc lamella media while allowing
the clear water to flow over the tank.to Aeration tank for further biological treatment.
Aeration Tank :- As the sewage enters this particular phase of treatment, the microorganisms are introduced. The
aeration tank with MBBR technology normally provides 4 hours retention time for the wastewater. The aeration tank
is agitated with diffused air that is fed by an air blower, and dispersed in the tank with spargers. Air maintains an
aerobic environment (dissolved oxygen present) in a mixed liquor of wastewater and an activated sludge, which
contains microorganisms that upon contact, will absorb organic matter from the waste water and convert it to
additional biological cells (activated sludge) and respiration products CO2 and H2O are produced. The Aeration tank
is filled with Bio media to increase the area for the Bacterial growth. This Technology is called as MBBR (Moving
Bed Bio Reactor) and is utilized to reduce the size of the STP. The activated sludge developed in the aeration tank
flocculates and settles. It readily separates from treated wastewater and is directed to the Secondary Clarifier.
Secondary Clarifier :- After the aeration stage, the Mixed Liquor (microorganism and wastewater) enter the
secondary clarifier. Here the velocity of the waste water is slowed to allow for the biomass to clump together and
settle to the bottom while allowing the clear water to flow over the tank weirs. Sludge transfer pumps return the
microorganisms from the bottom of the clarifier and return them to the beginning of the aeration tank. During the
aeration treatment the microorganisms reproduce in great numbers. To keep the system in check a portion of the
sludge is removed through a wasting process. The wasted sludge is sent to the sludge holding sump. The clear
water at the top of the clarifier overflows through openings at the top of the chamber. From the clarifier the clear
wastewater flows to a Chlorine Contact tank Chlorine is dosed.
Chlorine Contact Tank :- in this tank we add liquid chlorine to disinfect the clarified water.
Tertiary Treatment :- The fully treated and clarified sewage is pumped to the Sand Filter and Activated
Carbon Filter for filtering and polishing purpose. Suspended solids are removed in the filter as well as the
organic matters in the form of suspended solids are also removed.
4 Electronic dosing pump 0-5 lph for pH Correction dosing 1 No. URN/E dose/I dose
5 Electronic dosing pump 0-5 lph for coagulation dosing 1 No. URN/E dose/I dose
6 Electronic dosing pump 0-5 lph for flocculation dosing 1 No. URN/E dose/I dose
7 Electronic dosing pump 0-5 lph for Chlorine dosing 1 No. URN/E dose/I dose
10 Fine bubble non-clog type diffusers with piping, 90mm x 1000mm A Lot. Reputed
12 Tube deck Media for Settler 750mm Height A Lot Vasu Pharmatech
SCOPE OF WORK:
Design, preparation and approval of drawings, supply, installation, testing and commissioning of ESTP only
mechanical & electrical work as per the details given in the scope of supply.
Civil work with related MS work shall be beyond our scope. We shall provide GA & section/elevation drawing for
civil work.
We shall provide operation training of system for 3 days to your operational team
NOTE: These are the tentative sizes as per standard design practices which may change at the time
of detailed engineering for the betterment of the system.
SR NO DESCRIPTION PRICE
PAYMENT TERMS
b. 50% Advance along with the confirmed Purchase order
c. 30% Against Performa Invoice before dispatch
d. 10% After Successful Erection and Commissioning
e. 10% after successful Commissioning of the plant