C) All Relays Have Moving Parts.: A) Physical Size

The document contains questions about relays and programmable logic controllers (PLCs). Relays are electromechanical switches that can be used to interface circuits and usually have moving parts. PLCs are programmable controllers that use a microprocessor and ladder logic programming to control machines and processes. PLCs are designed to minimize the use of relays for control and provide flexible, reliable and low-cost control.

Uploaded by

Ahmed El-Fayoumy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views

C) All Relays Have Moving Parts.: A) Physical Size

The document contains questions about relays and programmable logic controllers (PLCs). Relays are electromechanical switches that can be used to interface circuits and usually have moving parts. PLCs are programmable controllers that use a microprocessor and ladder logic programming to control machines and processes. PLCs are designed to minimize the use of relays for control and provide flexible, reliable and low-cost control.

Uploaded by

Ahmed El-Fayoumy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Slides 1 in PlC Introduction

1) Which of the following statements is NOT true about relays?

A)A relay can be used to interface two different circuits.

B)A relay is basically an electromechanical switch.

C)All relays have moving parts.

D)A relay usually has at least one N.O. and one N.C. contact.

2) Which of the following is NOT a typical rating or specification for relays?


A)physical sizeB)coil resistanceC)contact current ratingD) coil voltage

3) An on-delay timing relay is set at 30 seconds. One minute after the trigger signal has
been applied to the relay, the solenoid valve connected to this relays N.C. contacts
continues to operate. What does this indicate?

A)The solenoid valve is operating as expected after the 30 second time has elapsed.

B)There is a malfunction with the relay or the circuit.

C)The solenoid valve was initially "off" but is now turned "on."

D) The solenoid valve will shut off after more time has elapsed.

4) Which application below would be an appropriate use of a contactor?

A)control of a hydraulic solenoid valveB)interfacing to an air pressure switch

C)turning ON an indicator lampD) turning ON warehouse lights

5) Which of the following is NOT a good application of relays?

A)controlling a 480 VAC load with a 24 VDC control signal

B)controlling 3 kW heater bands on an extruder barrel

C)micro-electronic switching circuit

D) elevator controls

6) Which of the following are considered relay options?

A)movable contactsB)LED on indicatorC)manual override buttonD) both b & c

7) Which of the following relay contact arrangements would be capable of switching three
independent loads ON and OFF simultaneously?

A)three pole, single throwB)double pole, double throw

C)three pole, double throwD) both a and c

8) The term _______ designates the number of points in a set of contacts where the
current will be interrupted during opening of the contacts.

A)poleB)throwC)breakD) double pole


9) The term _______ designates the number of isolated circuits that can pass through the
relay at one time.

A)poleB)throwC)breakD) double pole

10) Which of the following relay contact arrangements would be represented by Double
pole Single throw Single break?None

11) Relays can be tested usingAll

A) test light B) continuity light C) DVOM D) jumper wire

12) Connection of the Logic Inputs is

A) Direct B) via interposing relays

C)Either A or B D)Neither A nor B

13) To provide overload protection for a motor installed in a location with a constant
ambient temperature while the overload relay is installed in a location with a varying
ambient temperature, It is better to use

A) Ambient Compensated Thermal Overload Relay B) standard thermal overload relay

C) Contactor as overload protective device C) Fuses

14) Which is a correct statement:All

A) Three-wire control can automatically provide low voltage protection for motor.

B) 2-wire control scheme can automatically without the attention of an operaton provide
low voltage release of motor .

C) 3-wire control scheme uses momentary contact push buttons to energize the starter coil.

D) 2-wire control scheme uses maintained contact pilot device in series with the starter coil.

**For questions from 15 to 19 ,use figure 1 shown below :


15) These schematic diagram for power circuit and control circuits are descriped according
to :

A) NEMA B) IEC C) NA D) We can not know exactly

16) The method of starting of this motor is:

A)Direct-on-line start B) Star-delta

C) With start-up transformers D) With starting resistors

17) From power circuit , we can deduce that :All

A) Motor has only one speed

B) Grounding is IT type

C) Contactor is DIUL reversing type

D) Short circuit protection for contactor and overload relay is made by means of fuse F1

18) The main difference between control circuits a , and b is thatNone

A) for a , Changing direction of rotation is without actuation of the 0 pushbutton

B) for b , Changing direction of rotation is after actuation of the 0 pushbutton

C) I pushbutton is for Clockwise operation

D) II pushbutton is for anticlockwise operation

19) The control circuit device S11:All

A) is Three way pushbutton B) acts as Double pole

C) acts as Single break D) acts as single throw

20) The term PLC stands for:

A) Programmable local computer B) Personal logic computer

C) programmable logic controller D) Personal logic controller

21) PlCs and microcontrollers have All

A)Microprocessor Based
B)Onboard Memory for Storing Programs

C)Special Programming Language: Ladder Logic

D)Input/Output Ports

22) PlCs and microcontrollers have

A) Special Programming Language: Ladder LogicB)High Power

C)I/O Designed to interface with Control RelaysD)Maximum Reliability

23)PLCs are designed toAll

A)Minimize the Number of Control Relays in a Process

B)Maximize the Ways Relays can be Used

C) to be applied first in Automobile Industry

D)Flexible, Reliable and Low Cost