53 Grade Ordinary Portland Cement

Despatched during Week No. From 9-Sep-2020 To 15-Sep-2020


Test Certificate No. 37
Reference No. WCW/IMS/QA/FM/08
Dated 14-Oct-2020

Results Requirement as per IS 269 : 2015


S.N. Parameters
Obtained (Variety: OPC 53)

Chemical Composition
Lime Saturation Factor
Not greater than 1.02 and not less than 0.80
( CaO – 0.7 *SO3) / (2.8* SiO2 + 1.2* Al2O3 + 0.65* Fe2O3)

Ratio of % Alumina to that of Iron Oxide


Not less than 0.66
Al2O3 / Fe2O3

1 Insoluble Residue (% by mass) Not more than 5.0 %

Magnesia (% by mass) Not more than 6.0 %

Sulphuric Anhydride (% by mass) Not More than 3.5 %

Total loss on Ignition (%) Not More than 4.0 %

Not more than 0.1 % for general purpose & not


Chloride Content (%) more than 0.05 % for pre-stressed structures

Physical Analysis
Fineness
2
Blaine’s Specific Surface Area (m2 / kg) Not Less than 225
Compressive Strength (MPa)
72 ± 1h (3 Days) Not less than 27.0
3
168 ± 2h (7 Days) Not less than 37.0
672 ± 4h (28 Days) * Not less than 53.0
Setting Time (Minutes)
4 Initial Not less than 30
Final Not more than 600
Soundness
5 Le-Chatelier Expansion (mm) Not more than 10.0
Auto-Clave Expansion (%) Not more than 0.8
Normal Consistency (%)
6
Temp. During Testing (0C) (27 ± 2)0C

The above cement complies with the requirements of IS 269 : 2015 (Variety: OPC 53) for 53 Grade
Ordinary Portland Cement

Granulated Slag (4%) & Limestone (1%) added as Performance Improver